Sample records for spinal puncture

  1. Post spinal puncture headache, an old problem and new concepts: review of articles about predisposing factors

    PubMed Central

    Jabbari, Ali; Alijanpour, Ebrahim; Mir, Mehrafza; Bani hashem, Nadia; Rabiea, Seyed Mozaffar; Rupani, Mohammad Ali

    2013-01-01

    Post spinal puncture headache (PSPH) is a well known complication of spinal anesthesia. It occurs after spinal anesthesia induction due to dural and arachnoid puncture and has a significant effect on the patient’s postoperative well being. This manuscript is based on an observational study that runs on Babol University of Medical Sciences and review of literatures about current concepts about the incidence, risk factors and predisposing factors of post spinal puncture headache. The overall incidence of post-dural puncture headache after intentional dural puncture varies form 0.1-36%, while it is about 3.1% by atraumatic spinal needle 25G Whitacre. 25G Quincke needle with a medium bevel cutting is popular with widespread use and the incidence of PSPH is about 25%, but its incidence obtained 17.3% by spinal needle 25G Quincke in our observation. The association of predisposing factors like female, young age, pregnancy, low body mass index, multiple dural puncture, inexpert operators and past medical history of chronic headache, expose the patient to PSPH. The identification of factors that predict the likelihood of PSPH is important so that measures can be taken to minimize this painful complication resulting from spinal anesthesia. PMID:24009943

  2. Lower incidence of postdural puncture headache using whitacre spinal needles after spinal anesthesia: A meta-analysis.

    PubMed

    Zhang, Di; Chen, LingXiao; Chen, XingYu; Wang, XiaoBo; Li, YuLin; Ning, GuangZhi; Feng, ShiQing

    2016-03-01

    The aim of this meta-analysis was to evaluate the postdural puncture headache after spinal anesthesia with Whitacre spinal needles compared with Quincke spine needles. We searched several databases, including PubMed, Embase, ISI Web of Knowledge, and Cochrane Central Register of Controlled Trials until October 10th, 2014, for randomized controlled trials that compared spinal anesthesia with Whitacre spinal needles or Quincke spine needles for postdural puncture headache. Two reviewers independently screened the literature, assessed the risk for bias and extracted data. We used RevMan 5.3 software to perform the meta-analysis. Studies were included for the main end points if they addressed the following: frequency of postdural puncture headache, severity of postdural puncture headache as assessed by limitation of activities, and frequency of epidural blood patch. Nine randomized controlled trials were included for meta-analysis. The meta-analysis showed that spinal anesthesia with Whitacre spinal needles achieved lower incidence of postdural puncture headache(RR 0.34; 95% CI [0.22, 0.52]; P < .00001); in addition, the severity of postdural puncture headache was lower in the Whitacre spinal needle group (RR 0.32; 95% CI [0.16, 0.66]; P = .002). Furthermore, the frequency of an epidural blood patch in the Whitacre spinal needle group was lower compared with that in the Quincke spine needle group (RR 0.15; 95% CI [0.04, 0.51]; P = .002). We suggest the Whitacre spinal needles as a superior choice for spinal anesthesia compared with Quincke spine needles. © 2016 American Headache Society.

  3. Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device.

    PubMed

    Ambastha, Shikha; Umesh, Sharath; Dabir, Sundaresh; Asokan, Sundarrajan

    2016-11-01

    A technique for real-time dynamic monitoring of force experienced by a spinal needle during lumbar puncture using a fiber Bragg grating (FBG) sensor is presented. The proposed FBG force device (FBGFD) evaluates the compressive force on the spinal needle during lumbar puncture, particularly avoiding the bending effect on the needle. The working principle of the FBGFD is based on transduction of force experienced by the spinal needle into strain variations monitored by the FBG sensor. FBGFD facilitates external mounting of a spinal needle for its smooth insertion during lumbar puncture without any intervention. The developed FBGFD assists study and analysis of the force required for the spinal needle to penetrate various tissue layers from skin to the epidural space; this force is indicative of the varied resistance offered by different tissue layers for the spinal needle traversal. Calibration of FBGFD is performed on a micro-universal testing machine for 0 to 20 N range with an obtained resolution of 0.021 N. The experimental trials using spinal needles mounted on FBGFD are carried out on a human cadaver specimen with punctures made in the lumbar region from different directions. Distinct forces are recorded when the needle encounters skin, muscle tissue, and a bone in its traversing path. Real-time spinal needle force monitoring using FBGFD may reduce potentially serious complications during the lumbar puncture, such as overpuncturing of tissue regions, by impeding the spinal needle insertion at epidural space.

  4. Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device

    NASA Astrophysics Data System (ADS)

    Ambastha, Shikha; Umesh, Sharath; Dabir, Sundaresh; Asokan, Sundarrajan

    2016-11-01

    A technique for real-time dynamic monitoring of force experienced by a spinal needle during lumbar puncture using a fiber Bragg grating (FBG) sensor is presented. The proposed FBG force device (FBGFD) evaluates the compressive force on the spinal needle during lumbar puncture, particularly avoiding the bending effect on the needle. The working principle of the FBGFD is based on transduction of force experienced by the spinal needle into strain variations monitored by the FBG sensor. FBGFD facilitates external mounting of a spinal needle for its smooth insertion during lumbar puncture without any intervention. The developed FBGFD assists study and analysis of the force required for the spinal needle to penetrate various tissue layers from skin to the epidural space; this force is indicative of the varied resistance offered by different tissue layers for the spinal needle traversal. Calibration of FBGFD is performed on a micro-universal testing machine for 0 to 20 N range with an obtained resolution of 0.021 N. The experimental trials using spinal needles mounted on FBGFD are carried out on a human cadaver specimen with punctures made in the lumbar region from different directions. Distinct forces are recorded when the needle encounters skin, muscle tissue, and a bone in its traversing path. Real-time spinal needle force monitoring using FBGFD may reduce potentially serious complications during the lumbar puncture, such as overpuncturing of tissue regions, by impeding the spinal needle insertion at epidural space.

  5. Difficulties in spinal needle use. Insertion characteristics and failure rates associated with 25-, 27- and 29-gauge Quincke-type spinal needles.

    PubMed

    Tarkkila, P; Huhtala, J; Salminen, U

    1994-08-01

    The effect of different size (25-, 27- and 29-gauge) Quincke-type spinal needles on the incidence of insertion difficulties and failure rates was investigated in a randomised, prospective study with 300 patients. The needle size was randomised but the insertion procedure was standardised. The time to achieve dural puncture was significantly longer with the 29-gauge spinal needle compared with the larger bore needles and was due to the greater flexibility of the thin needle. However, the difference was less than 1 min and cannot be considered clinically significant. There were no significant differences between groups in the number of insertion attempts or failures and the same sensory level of analgesia was reached with all the needle sizes studied. Postoperatively, no postdural puncture headaches occurred in the 29-gauge spinal needle group, whilst in the 25- and 27-gauge needle groups, the postdural puncture headache rates were 7.4% and 2.1% respectively. The incidence of backache was similar in all study groups. We conclude that dural puncture with a 29-gauge spinal needle is clinically as easy as with larger bore needles and its use is indicated in patients who have a high risk of postdural puncture headache.

  6. Comparison of cutting and pencil-point spinal needle in spinal anesthesia regarding postdural puncture headache

    PubMed Central

    Xu, Hong; Liu, Yang; Song, WenYe; Kan, ShunLi; Liu, FeiFei; Zhang, Di; Ning, GuangZhi; Feng, ShiQing

    2017-01-01

    Abstract Background: Postdural puncture headache (PDPH), mainly resulting from the loss of cerebral spinal fluid (CSF), is a well-known iatrogenic complication of spinal anesthesia and diagnostic lumbar puncture. Spinal needles have been modified to minimize complications. Modifiable risk factors of PDPH mainly included needle size and needle shape. However, whether the incidence of PDPH is significantly different between cutting-point and pencil-point needles was controversial. Then we did a meta-analysis to assess the incidence of PDPH of cutting spinal needle and pencil-point spinal needle. Methods: We included all randomly designed trials, assessing the clinical outcomes in patients given elective spinal anesthesia or diagnostic lumbar puncture with either cutting or pencil-point spinal needle as eligible studies. All selected studies and the risk of bias of them were assessed by 2 investigators. Clinical outcomes including success rates, frequency of PDPH, reported severe PDPH, and the use of epidural blood patch (EBP) were recorded as primary results. Results were evaluated using risk ratio (RR) with 95% confidence interval (CI) for dichotomous variables. Rev Man software (version 5.3) was used to analyze all appropriate data. Results: Twenty-five randomized controlled trials (RCTs) were included in our study. The analysis result revealed that pencil-point spinal needle would result in lower rate of PDPH (RR 2.50; 95% CI [1.96, 3.19]; P < 0.00001) and severe PDPH (RR 3.27; 95% CI [2.15, 4.96]; P < 0.00001). Furthermore, EBP was less used in pencil-point spine needle group (RR 3.69; 95% CI [1.96, 6.95]; P < 0.0001). Conclusions: Current evidences suggest that pencil-point spinal needle was significantly superior compared with cutting spinal needle regarding the frequency of PDPH, PDPH severity, and the use of EBP. In view of this, we recommend the use of pencil-point spinal needle in spinal anesthesia and lumbar puncture. PMID:28383416

  7. Is there a difference in postdural puncture headache after continuous spinal anesthesia with 28G microcatheters compared with punctures with 22G Quincke or Sprotte spinal needles?

    PubMed

    Lux, Eberhard Albert; Althaus, Astrid

    2014-01-01

    In this retrospective study, the question was raised and answered whether the rate of postdural puncture headache (PDPH) after continuous spinal anesthesia with a 28G microcatheter varies using a Quincke or a Sprotte needle. The medical records of all patients with allogenic joint replacement of the knee or hip or arthroscopic surgery of the knee joint undergoing continuous spinal anesthesia with a 22G Quincke (n=1,212) or 22G Sprotte needle (n=377) and a 28G microcatheter during the past 6 years were reviewed. We obtained the approval of the ethical committee. The rates of PDPH were statistically not different between both groups: 1.5% of patients developed PDPH after dura puncture with a Quincke needle and 2.1% with a Sprotte needle in women and men.

  8. Is there a difference in postdural puncture headache after continuous spinal anesthesia with 28G microcatheters compared with punctures with 22G Quincke or Sprotte spinal needles?

    PubMed Central

    Lux, Eberhard Albert; Althaus, Astrid

    2014-01-01

    In this retrospective study, the question was raised and answered whether the rate of postdural puncture headache (PDPH) after continuous spinal anesthesia with a 28G microcatheter varies using a Quincke or a Sprotte needle. The medical records of all patients with allogenic joint replacement of the knee or hip or arthroscopic surgery of the knee joint undergoing continuous spinal anesthesia with a 22G Quincke (n=1,212) or 22G Sprotte needle (n=377) and a 28G microcatheter during the past 6 years were reviewed. We obtained the approval of the ethical committee. The rates of PDPH were statistically not different between both groups: 1.5% of patients developed PDPH after dura puncture with a Quincke needle and 2.1% with a Sprotte needle in women and men. PMID:25419159

  9. Does Spinal Block Through Tattooed Skin Cause Histological Changes in Nervous Tissue and Meninges?: An Experimental Model in Rabbits.

    PubMed

    Ferraz, Isabela Leite; Barros, Guilherme Antônio Moreira de; Ferreira Neto, Patrícia Gomes; Solanki, Daneshivari; Marques, Mariângela Alencar; Machado, Vânia Maria de Vasconcelos; Cabral, Lucas Wynne; Lima, Rodrigo Moreira E; Vianna, Pedro Thadeu Galvão; Navarro, Lais Helena Camacho; Ganen, Eliana Marisa

    2015-01-01

    Although there is no documented evidence that tattoo pigments can cause neurological complications, the implications of performing neuraxial anesthesia through tattooed skin are unknown. In this study, we aimed to assess whether spinal puncture performed through tattooed skin of rabbits determines changes over the spinal cord and meninges. In addition, we sought to evaluate the presence of ink fragments entrapped in spinal needles. Thirty-six young male adult rabbits, each weighing between 3400 and 3900 g and having a spine length between 38.5 and 39 cm, were divided by lot into 3 groups as follows: GI, spinal puncture through tattooed skin; GII, spinal puncture through tattooed skin and saline injection; and GIII, spinal puncture through skin free of tattoo and saline injection. After intravenous anesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance with a 22-gauge 2½ Quincke needle. Animals in GII and GIII received 5 μL/cm of spinal length (0.2 mL) of saline intrathecally. In GI, the needle tip was placed into the yellow ligament, and no solution was injected into the intrathecal space; after tattooed skin puncture, 1 mL of saline was injected through the needle over a histological slide to prepare a smear that was dyed by the Giemsa method to enable tissue identification if present. All animals remained in captivity for 21 days under medical observation and were killed by decapitation. The lumbosacral spinal cord portion was removed for histological analysis using hematoxylin-eosin stain. None of the animals had impaired motor function or decreased nociception during the period of clinical observation. None of the animals from the control group (GIII) showed signs of injuries to meninges. In GII, however, 4 animals presented with signs of meningeal injury. The main histological changes observed were focal areas of perivascular lymphoplasmacyte infiltration in the pia mater and arachnoid. There was no signal of injury in neural tissue in any animal of both groups. Tissue coring containing ink pigments was noted in all GI smears from the spinal needles used to puncture the tattooed skin. On the basis of the present results, intrathecal injection of saline through a needle inserted through tattooed skin is capable of producing histological changes over the meninges of rabbits. Ink fragments were entrapped inside the spinal needles, despite the presence of a stylet.

  10. Comparison of post-dural puncture headache and low back pain between 23 and 25 gauge Quincke spinal needles in patients over 60 years: randomized, double-blind controlled trial.

    PubMed

    Kim, Meehyoung; Yoon, Haesang

    2011-11-01

    Even though the use of a 25 gauge or smaller Quincke needle is recommended for spinal anesthesia to reduce post-dural puncture headache in Korea, lumbar puncture in older patients using a 25 gauge or smaller Quincke needle can be difficult. However, most previous studies concerning post-dural puncture headache have chosen children, parturients, and young adults as study participants. The study compared post-dural puncture headache, post-operative back pain, and the number of lumbar puncture attempts using a 23 or 25 gauge Quincke needle for spinal anesthesia of Korean patients >60-years-of-age. Randomized, double-blinded controlled trial. The 53 participants who underwent orthopedic surgery under spinal anesthesia were recruited by informed notices from December 2006 through August 2007 at a 200-bed general hospital located in Kyunggido. Inclusion criteria were an age >60 years, ASA I-II, and administration of patient controlled analgesia for the first 48 h post-operatively. The 53 patients were randomly allocated to either the experimental (23 gauge Quincke needle) or control group (25 gauge Quincke needle). All patients had 24 h bed rest post-operatively. Post-dural puncture headache was assessed by the Dittmann Scale and post-operative back pain was assessed by a visual analogue scale at 24, 48, and 72 h post-operatively. The statistical methods included the Mann-Whitney U-test and Spearman correlation. There were no differences in post-dural puncture headache, and post-operative back pain at 24, 48, and 72 h post-operatively, and no differences in the number of lumbar punctures, with the 23 and 25 gauge Quincke needle. Forty-eight hour post-operative back pain was positively associated with the number of lumbar punctures (p=.036) and age (p=.040). There were no statistically significant associations among post-dural puncture headache, the number of lumbar punctures, and 48 h post-operative back pain. Pre-operative back pain was positively associated with 48 h post-operative back pain (p<.001). The choice of a 23 or 25 gauge Quincke needle for spinal anesthesia has no significant influence on post-dural puncture headache and post-operative back pain for Korean patients greater than 60-years-of-age. The 23 gauge Quincke needle is an option for lumbar punctures in this patient population. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Comparison of 27-gauge (0.41-mm) Whitacre and Quincke spinal needles with respect to post-dural puncture headache and non-dural puncture headache.

    PubMed

    Santanen, U; Rautoma, P; Luurila, H; Erkola, O; Pere, P

    2004-04-01

    The incidence of headache after spinal anaesthesia has varied greatly between studies. We compared the incidence of postoperative headache in general and postdural puncture headache (PDPH) when using 27-gauge (G) (outer diameter 0.41 mm) Quincke and Whitacre spinal needles in ambulatory surgery performed under spinal anaesthesia. In a prospective, randomized study, 676 ASA physical status I-II day-case outpatients were given a spinal anaesthetic through either a 27-G (0.41 mm) Quincke or a 27-G (0.41 mm) Whitacre spinal needle. The incidence of any type of postoperative headache was assessed and the type of headache defined using a standardized questionnaire including PDPH criteria. The severity of the headache was defined using a 100-mm visual analogue scale. For the final analysis, 529 patients were available (259 patients in the Quincke group and 270 patients in the Whitacre group). The overall incidence of postoperative headache was 20.0%, but the incidence of true PDPH was very low (1.51%). The incidence of PDPH in the Quincke group was 2.70%, while in the Whitacre group it was only 0.37% (P < 0.05). The overall incidence of non-dural puncture headache was 18.5% and did not differ between the study groups. True PDPH seldom occurs when a 27-G (0.41 mm) spinal needle is used, although postoperatively a non-specific headache is common. Using the 27-G (0.41 mm) Whitacre spinal needle further reduced the incidence of PDPH. Thus, we recommend routine use of the 27-G (0.41 mm) Whitacre spinal needle when performing spinal anaesthesia.

  12. Onyx injection by direct puncture for the treatment of hypervascular spinal metastases close to the anterior spinal artery: initial experience.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Sourour, Nader-Antoine; Enkaoua, Eric; Sailhan, Frédéric; Iosif, Christina; Le Jean, Lise; Chiras, Jacques

    2013-06-01

    Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the feeders of the metastases and the feeders of the anterior spinal artery (ASA) poses a risk of spinal cord ischemia when PVA microparticle embolization is performed. The authors present their early experience in the treatment of spinal metastases close to the ASA; in 2 cases they injected Onyx-18, by direct puncture, into hypervascular posterior arch spinal metastases situated close to the ASA. Two women, one 36 and the other 55 years of age, who presented with spinal lesions (at the posterior arch of C-4 and T-6, respectively) from thyroid and a kidney tumors, were sent to the authors' department to undergo presurgical embolization. After having performed a complete spinal digital subtraction angiography study, a regular angiography catheter was positioned at the ostium of the artery that mainly supplied the lesion. Then, with the patient in the left lateral decubitus position, direct puncture with 18-gauge needles of the lesion was performed using roadmap guidance. Onyx-18 was injected through the needles under biplanar fluoroscopy. Satisfactory devascularization of the lesions was obtained; the ASA remained patent in both cases. The metastases were surgically removed in both cases within the 48 hours after the embolization and major blood loss did not occur. Presurgical devascularization of hypervascular spinal metastases close the ASA by direct puncture with Onyx-18 seems to be an effective technique and appears to be safe in terms of the preserving the ASA's patency.

  13. Does Atraucan cause more postdural puncture backache?

    PubMed

    Abdullayev, Ruslan; Küçükebe, Omer Burak; Çelik, Bülent; Kirman, Nihal; Hatipoğlu, Hamit Sinan; Akaltun Hatipoğlu, Filiz

    2015-01-01

    Postdural puncture backache (PDPB) is the most frequent complaint after spinal anesthesia. In the literature its importance is generally overshadowed by postdural puncture headache. We studied two different kinds of spinal anesthesia needles to compare their technical handling capacities and incidences of PDPB. Data of 256 pregnant female patients undergoing cesarean delivery under spinal anesthesia were collected for the study. Patients were divided into two groups as Group A (n = 109) and Group Q (n = 147) according to the spinal needle used for spinal anesthesia (i.e. 26-gauge atraumatic and 26-gauge Quincke needles, respectively). Backache incidences during a 1-week period postoperatively and handling characteristics of the needles were noted. Spinal anesthesia was successfully performed at one attempt in 92.7% and 86.4% of patients in Groups A and Q, respectively. PDPB was encountered in 62.4% and 44.2% of patients in Groups A and Q, respectively, and the difference was statistically significant (P = 0.037). Both 26-gauge Atraucan and Quincke needles have excellent handling characteristics. PDPB seems to be less common with the 26-gauge Quincke needle than with the Atraucan needle.

  14. Comparison of Sprotte and Quincke needles with respect to post dural puncture headache and backache.

    PubMed

    Tarkkila, P J; Heine, H; Tervo, R R

    1992-01-01

    The objective of this study was to compare 24-gauge Sprotte and 25-gauge Quincke needles with respect to post dural puncture headache and backache. Three hundred ASA Physical Status I or II patients scheduled for minor orthopedic or urologic operations under spinal anesthesia were chosen for this randomized, prospective study at a university hospital and a city hospital. Anesthetic technique, intravenous fluids, and postoperative pain therapy were standardized. Patients were randomly divided into three equal groups. Spinal anesthesia was performed with either a 24-gauge Sprotte needle or a 25-gauge Quincke needle with the cutting bevel parallel or perpendicular to the dural fibers. Anesthesia could not be performed in three cases with the Sprotte needle and in one case with the Quincke needle. The most common complications were post dural puncture backache (18.0%), post dural puncture headache (8.2%), and non-postural headache (6.7%). No major complications occurred. The Quincke needle with bevel perpendicular to the dural fibers caused a 17.9% incidence of post dural puncture headache. The Quincke with bevel parallel to the dural fibers and the Sprotte needles caused similar post dural puncture headache rates (4.5% and 2.4%, respectively). Other factors associated with post dural puncture headache were young age, early ambulation, and sedation during spinal anesthesia. There were no significant differences between needles in the incidence of post dural puncture backache. Our data indicate that Quincke needles should not be used with the needle bevel inserted perpendicular to the dural fibers. The Sprotte needle does not solve the problem of post dural puncture headache and backache.

  15. Comparison of 25 G and 29 G Quincke spinal needles in paediatric day case surgery. A prospective randomized study of the puncture characteristics, success rate and postoperative complaints.

    PubMed

    Kokki, H; Hendolin, H

    1996-01-01

    A comparison of a 25 G with a 29 G Quincke needle was performed in paediatric day case surgery. Sixty healthy children aged 1 year to 13 years were randomly allocated to have spinal anaesthesia with either 25 G or 29 G Quincke needle without an introducer needle. There was a failure rate of 10% with the 29 G spinal needle compared with 0% with the 25 G needle. The time needed to perform dural puncture was shorter using 25 G than 29 G needle, 22 (+/- 31)(SD) vs 59 (+/- 63) s. The time taken for cerebrospinal fluid to appear at the needle hub was also longer, 4 (+/- 3) vs 8 (+/- 5) s. The number of puncture attempts was similar, 1.2 (+/- 0.6) vs 1.4 (+/- 0.8), with 25 G and 29 G needle. Low back pain, 5 vs1, and nonpositional headache, 2 vs 4, after 25 G and 29 G needles, respectively, were the most frequent postoperative complaints. Mild postdural puncture headache occurred in one eight year old male patient in the 25 G group. In conclusion, lumbar puncture without introducer needle was possible with both needles. The puncture characteristics favoured the 25 G needle. A shorter needle could partly alleviate the difficulties with the 29 G needle.

  16. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    PubMed

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  17. Comparison of 25-gauge, Quincke and Whitacre needles for postdural puncture headache in obstetric patients.

    PubMed

    Bano, Fauzia; Haider, Saeeda; Aftab, Sadqa; Sultan, S Tipu

    2004-11-01

    To compare the frequency of postdural puncture headache (PDPH) and failure rate of spinal anesthesia using 25-gauge Quincke and 25-gauge Whitacre needles in obstetric patients. Single blinded, interventional experimental study. This study was conducted at the Department of Anesthesiology, Pain Management and Surgical Intensive Care Unit, Dow University of Health Sciences and Civil Hospital, Karachi from November 1, 2003-April 15, 2004. One hundred females, aged 18-35 years, ASA physical status I and II, with singleton pregnancy undergoing elective or emergency cesarean section under spinal anesthesia were randomly allocated to receive spinal anesthesia either by using 25-gauge Quincke or 25-gauge Whitacre needles. Patients were followed for 3 days postoperatively. Headache, its relation with posture, onset, duration, severity and response to the treatment were recorded. Compared with the Whitacre group, frequency of postdural puncture headache was significantly higher in Quincke group (*p=0.015), while the overall occurrence of non-postdural puncture headache (NPDPH) did not differ significantly between two groups (p=0.736). Most of PDPH developed on 2nd postoperative day, were mild in nature and resolved within 48 hours of their onset. There was no significant difference in the failure rate of spinal anesthesia in both groups (p=0.149). It is suggested that use of 25-gauge Whitacre needle reduces the frequency of PDPH without increasing the failure rate of spinal anesthesia in obstetric patients.

  18. Effects caused by the spinal administration of ketamine S (+) 5% with no preservatives, using a single puncture, and located on the spinal cord and meninges in rabbits.

    PubMed

    Lima Filho, José Admirço; Fin, Natalia Castro; Valerini, Felipe Gilberto; Machado, Vania Maria; Marques, Mariangela Ester; Miot, Hélio; Lima, Lais Helena Navarro E; Ganen, Eliana Marisa

    2014-07-01

    To evaluate the effect of ketamine S (+) 5% with no preservatives and administered as a subarachnoid single puncture on the spinal cord and meninges of rabbits. Twenty young adult female rabbits, each weighing 3500-5000 g and having a spine length between 34 and 38 cm, were divided by lot into two groups (G): 0.9% saline in G1 and ketamine S (+) 5% in G2, by volume of 5 μg per cm column (0.18 mL). After intravenous anaesthesia with ketamine and xylazine, the subarachnoid space was punctured at S1-S2 under ultrasound guidance, and a random solution was injected. The animals remained in captivity for 21 days under medical observation and were sacrificed by decapitation. The lumbosacral spinal cord portion was removed for immunohistochemistry to assess the glial fibrillary acidic protein (GFAP), and histology was assessed using hematoxylin and eosin (HE) stain. No histological lesions were found in the nervous tissue (roots and cord) or meninges in either group. The ketamine S (+) 5% unpreserved triggered no neurological or histological lesions in the spinal cord or meninges of rabbits.

  19. Lumbar Puncture (Spinal Tap) (For Parents)

    MedlinePlus

    ... specific bacteria growing in the sample, a bacterial culture is sent to the lab and these results ... treatment while waiting for the results of the culture. Risks A lumbar puncture is considered a safe ...

  20. Cranial nerve VI palsy after dural-arachnoid puncture.

    PubMed

    Hofer, Jennifer E; Scavone, Barbara M

    2015-03-01

    In this article, we provide a literature review of cranial nerve (CN) VI injury after dural-arachnoid puncture. CN VI injury is rare and ranges in severity from diplopia to complete lateral rectus palsy with deviated gaze. The proposed mechanism of injury is cerebrospinal fluid leakage causing intracranial hypotension and downward displacement of the brainstem. This results in traction on CN VI leading to stretch and neural demyelination. Symptoms may present 1 day to 3 weeks after dural-arachnoid puncture and typically are associated with a postdural puncture (spinal) headache. Resolution of symptoms may take weeks to months. Use of small-gauge, noncutting spinal needles may decrease the risk of intracranial hypotension and subsequent CN VI injury. When ocular symptoms are present, early administration of an epidural blood patch may decrease morbidity or prevent progression of ocular symptoms.

  1. Meningitis

    MedlinePlus

    ... and spinal cord. This covering is called the meninges. Causes The most common causes of meningitis are ... Kernig's sign of meningitis Lumbar puncture (spinal tap) Meninges of the brain Meninges of the spine Haemophilus ...

  2. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles.

    PubMed

    Shaikh, Jan Muhammad; Memon, Amna; Memon, Muhammad Ali; Khan, Majida

    2008-01-01

    To compare the frequency and severity of post dural puncture headache in obstetric patients using 25G Quincke, 27G Quincke and 27G Whitacre spinal needles. Comparative, randomized, double-blind, interventional study. Liaquat University Hospital Hyderabad from October 2005 to December 2006. 480 ASA I-II full term pregnant women, 18 to 45 years of age, scheduled for elective Caesarean section, under spinal anaesthesia, were randomized into three groups: Group I (25G Quincke spinal needle: n=168), Group II (27G Quincke spinal needle: n=160) and Group III (27G Whitacre spinal needle: n=152). Spinal anaesthesia was performed with 1.5-2.0 ml 0.75% hyperbaric bupivacaine using 25G Quincke spinal needle (Group I), 27G Quincke spinal needle (Group II) and 27G Whitacre spinal needle (Group III) at L3-4 inter-vertebral space. Each patient was assessed daily for four consecutive days following Caesarean section. Frequency and severity and of postdural puncture headache (PDPH) were recorded. Data were analyzed using SPSS-11. Frequency of PDPH following the use of 25G Quincke (Group I), 27G Quincke (Group II) and 27G Whitacre (Group III) spinal needles was 8.3% (14/168), 3.8% (6/160) and 2.0% (3/152) respectively. In Group I, PDPH was mild in 5 patients, moderate in 7 patients and severe in 2 patients. In Group II, it was mild in 2, moderate in 3 and severe in 1 patient. In group III, it was mild in 2 and moderate in 1 patient. Severe PDPH did not occur in Group III. Most of the patients with PDPH developed it on 1st and 2nd postoperative day. When using a 27G Whitacre spinal needle, the frequency and severity of PDPH was significantly lower than when a 25G Quincke or 27G Quincke needle was used.

  3. Spinal anaesthesia with 29 gauge Quincke point needles and post dural puncture headache in 2,378 patients.

    PubMed

    Dittmann, M; Schaefer, H G; Renkl, F; Greve, I

    1994-10-01

    Two thousand three hundred and seventy-eight spinal anaesthetics using a 29 G Quincke point needle were administered in a District Hospital between May 1983 and December 1991. The overall post dural puncture headache rate (PDPH) was 1.2% with a maximum of 2.5% in patients between age 30 and 39. PDPH was related to the experience of using 29 G needles (0.5% in consultants versus 2.0% in trainees, P < 0.05).

  4. Is the pencil point spinal needle a better choice in younger patients? A comparison of 24G Sprotte with 27G Quincke needles in an unselected group of general surgical patients below 46 years of age.

    PubMed

    Brattebø, G; Wisborg, T; Rodt, S A; Røste, I

    1995-05-01

    Reports have indicated that there are less postoperative complaints after the use of pencil pointed spinal needles. We compared a 24G Sprotte needle with a 27G Quincke needle in a randomised study of 200 healthy patients (49% females), aged 15-46 years. Four patients (2%) reported postdural puncture headache, three with the 24G Sprotte needle and one with the 27G Quincke needle. Thirteen patients (7%) suffered with nonspecific headache, with no significant difference between the two groups. Of the 57 (29%) who reported backpain, a significantly higher proportion had received spinal anaesthesia with the Sprotte needle (OR = 2.06). There was a significantly higher incidence of insufficient blocks after dural puncture with the Sprotte needle. Ease of needle insertion and number of puncture attempts was the same for both needle types.

  5. Evaluation of 25-gauge Quincke and 24-gauge Gertie Marx needles for spinal anaesthesia for caesarean section.

    PubMed

    Imarengiaye, C O; Edomwonyi, N P

    2002-07-01

    To compare the insertion characteristics and rate of complications between 25-gauge Quincke and 24-gauge Gertie Marx needles. Prospective, randomized study. University of Benin Teaching Hospital; a university-affiliated tertiary centre. Parturients (ASA 1 and 2) scheduled for elective caesarean section. They were randomly assigned to receive spinal anaesthesia with either 25-gauge Quincke needle or 24-gauge Gertie Marx needle. The patients with abnormal spaces, coagulopathy, infection, pre-eclampsia/eclampsia or obesity were excluded. The number of attempts at successful identification of the spinal space, intraoperative complications, incidence of postdural puncture headache (PDPH), non-postdural puncture headache (NPDPH) and backache. Sixty women were studied. The 24-gauge Gertie Marx needle resulted in more successful location of the spinal space on the second attempt (P<0.05). Non-postdural puncture headache was seen in 43% of the study population. PDPH was seen in 10% of the Quincke group and none in the Gertie Marx group. There was no difference in the incidence of backache in both groups. The ease of insertion and low incidence of PDPH with the Gertie Marx needle may encourage trainee anaesthetists to use this needle for caesarean section.

  6. Lumbar puncture (image)

    MedlinePlus

    ... is a clear fluid that circulates in the space surrounding the spinal cord and brain. CSF protects the brain and spinal cord from injury by acting like a liquid cushion. CSF is usually obtained through a lumbar ...

  7. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients.

    PubMed

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I-II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A ( n = 323) and 26-gauge Quincke spinal needles Group Q ( n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t -test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar ( P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q ( P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache ( P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q ( P > 0.05). The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients.

  9. The Postdural Puncture Headache and Back Pain: The Comparison of 26-gauge Atraucan and 26-gauge Quincke Spinal Needles in Obstetric Patients

    PubMed Central

    Akdemir, Mehmet Salim; Kaydu, Ayhan; Yanlı, Yonca; Özdemir, Mehtap; Gökçek, Erhan; Karaman, Haktan

    2017-01-01

    Background: The postdural puncture headache (PDPH) and postdural puncture backache (PDPB) are well-known complications of spinal anesthesia. There are some attempts to reduce the frequency of complication such as different design of the spinal needles. Aims: The primary outcome of this study is to compare the incidence of PDPH between 26-gauge Atraucan and 26-gauge Quincke spinal needles in elective cesarean operations. The severity of symptoms, the incidence of backache, technical issues, and comparison of cost of needles are secondary outcomes. Materials and Methods: After Investigational Review Board approval, a randomized, prospective, double-blinded study was designed in 682 American Society of Anesthesiologists I–II women having elective cesarean operations under spinal anesthesia. Patients were divided into two groups as 26-gauge Atraucan Group A (n = 323) and 26-gauge Quincke spinal needles Group Q (n = 342). All patients were questioned about backache 1 week later. Differences between categorical variables were evaluated with Chi-square test. Continuous variables were compared by Student's t-test for two independent groups. A two-sided P < 0.05 was considered statistically significant for all analyses. Results: There were no significant differences between groups in all demographic data. The one attempt success rate of the dural puncture in Group A (70,58%) and in Group Q (69.3%) was similar (P > 0.05). The incidence of PDPH was 6.5% in Group A and 4.9% in Group Q (P > 0.05). The epidural blood patch was performed to the three patients in Group A and five patients in Group Q who had severe headache (P > 0.05). The incidence of PDPB was 4.33% versus 2.04% in Group A and Group Q (P > 0.05). Conclusions: The incidence of complication rates and technical handling characteristics did not differ between two groups. Quincke needle is cheaper than Atracaun needle, so it can be a cost-effective choice in obstetric patients. PMID:28663641

  10. [A new two-chamber model for examination and demonstration of transdural fluid leakage after spinal anesthesia].

    PubMed

    Enk, D; Enk, E

    1995-11-01

    Various in vitro models have been introduced for comparative examinations of post-dural-puncture trauma and measurement of liquor leakage through puncture sites. These models allow simulation of subarachnoid, but not of peridural, pressure. A new two-chamber-model realizes the simulation of both subarachnoid and peridural pressure and allows observation of in vitro punctures with video-documentation. Frame grabbing and (computer-aided) image analysis show new aspects of spinal puncture effects. Therefore, post-dural-puncture trauma and retraction can be objectively visualized by this method, which has not previously been demonstrated. Two-chamber-model consists of two short aluminium cylinders. Native human dura patches (8X8 mm) from fresh cadavers are put (correctly oriented) between two special polyamide seals. Mounted between the upper and lower cylinder, these seals stretch the dura patch, which remains flexible and even in all directions. After filling of the lower (subarachnoid) and upper (peridural) chamber with Ringer lactate solution, positive or negative physiological pressure can be adjusted by way of two (Ringer lactate solution filled) infusion lines in each chamber. Puncturing is performed at an angle of 57 degrees to the dura. The model allows examination with epi-illumination and transmitted (polarized) light. In vitro punctures are observed through an inverted camera lens with an CCD-Hi8 video camera (Canon UC1HI) looking into the peridural chamber and documented by means of an S-VHS video recorder (Panasonic NV-FS200EG). After true-colour frame grabbing by a video digitizer (Fast Screen Machine II), single video frames can be optimized and analysed with a 486-66 MHz computer and conventional software (Corel Draw 3.0, Photostyler 1.1a, DDL Aequitas 1.00b). Punctures demonstrated in this paper have been done under simulation of a transdural gradient of 20 cm water similar to the situation of a recumbent patient (15 cm water in the subarachnoid and -5 cm water in the peridural chamber). The punctures were followed by short-time observation for up to 10 minutes. By making it possible to obtains a picture of the puncture site at 20-ms intervals (because of the PAL norm of 50 half-frames/s), video-documentation has become accepted as superior to conventional photography. When the Ringer lactate solution in the subarachnoid chamber is stained with methylene blue, transdural leakage can easily be observed. The result of this documentation technique demonstrate that not dural puncture can be atraumatic, when a 29-G Quincke needle is used. Calculation on the difference between a digitized video frame before and after the puncture clearly illustrates the dural trauma. Owing to their non-cutting tip, as expected, pencil-point needles leave diffuse changes across the dura patch, whereas a more local trauma was observed after puncturing with cutting-tip needles. The same computer calculation between two video frames allows examination of post-puncture-dural retraction of the puncture site. In this connection, we found that relevant dural retraction is a phenomenon limited to the first minute after puncture. Thin spinal needles with so-called modern tips (e.g. Whitacre, Atraucan) can minimize the post-dural-puncture trauma, whereas thicker, conventional, spinal needles (Quincke) leave considerable dural defects. The two-chamber-model presented allows easy simulation of physiological subarachnoid and peridural pressure. The Ringer lactate solution in the subarachnoid chamber corresponds to the liquor, whereas that in the peridural chamber corresponds to the intercellular (peridural) space. The tension of the dural patch between the polyamide seals is similar to the situation in an anotomical model observed by spinaloscopy (in an earlier study). With the video documentation and computer-aided analysis technique introduced, dural trauma and retraction of the puncture site can be examined and demo

  11. Postdural puncture headache is not an age-related symptom in children: a prospective, open-randomized, parallel group study comparing a22-gauge Quincke with a 22-gauge Whitacre needle.

    PubMed

    Kokki, H; Salonvaara, M; Herrgård, E; Onen, P

    1999-01-01

    Many reports have shown a low incidence of postdural puncture headache (PDPH) and other complaints in young children. The objective of this open-randomized, prospective, parallel group study was to compare the use of a cutting point spinal needle (22-G Quincke) with a pencil point spinal needle (22-G Whitacre) in children. We studied the puncture characteristics, success rate and incidence of postpuncture complaints in 57 children, aged 8 months to 15 years, following 98 lumbar punctures (LP). The patient/parents completed a diary at 3 and 7 days after LP. The response rate was 97%. The incidence of PDPH was similar, 15% in the Quincke group and 9% in the Whitacre group (P=0.42). The risk of developing a PDPH was not dependent on the age (r < 0.00, P=0.67). Eight of the 11 PDPHs developed in children younger than 10 years, the youngest being 23-months-old.

  12. Continuous Spinal Anesthesia for Obstetric Anesthesia and Analgesia

    PubMed Central

    Veličković, Ivan; Pujic, Borislava; Baysinger, Charles W.; Baysinger, Curtis L.

    2017-01-01

    The widespread use of continuous spinal anesthesia (CSA) in obstetrics has been slow because of the high risk for post-dural puncture headache (PDPH) associated with epidural needles and catheters. New advances in equipment and technique have not significantly overcome this disadvantage. However, CSA offers an alternative to epidural anesthesia in morbidly obese women, women with severe cardiac disease, and patients with prior spinal surgery. It should be strongly considered in parturients who receive an accidental dural puncture with a large bore needle, on the basis of recent work suggesting significant reduction in PDPH when intrathecal catheters are used. Small doses of drug can be administered and extension of labor analgesia for emergency cesarean delivery may occur more rapidly compared to continuous epidural techniques. PMID:28861414

  13. Continuous intrathecal baclofen infusion by a programmable pump in 131 consecutive patients with severe spasticity of spinal origin.

    PubMed

    Ordia, Joe I; Fischer, Edward; Adamski, Ellen; Chagnon, Kimberly G; Spatz, Edward L

    2002-01-01

    We began this study to determine the efficacy and safety of intrathecal baclofen (ITB) delivered by a programmable pump for the treatment of severe spasticity of spinal cord origin. One hundred fifty two patients with severe spasticity of spinal origin, refractory to oral baclofen, or who experienced intolerable side-effects were given a test dose of ITB. Only those who had a satisfactory response were considered to be appropriate for pump implantation. All but one of the 152 patients had a satisfactory response, and the pump was implanted in 131 patients. Pre- and postoperative spasticity scores were compared and analyzed. The mean Ashworth score for rigidity decreased from 4.2 preoperatively to 1.3 (p < 0.0005) on ITB. The spasm score decreased from a mean of 3.4 to 0.6 (p < 0.0005). Reduction of spasticity resulted in improved levels of physical activity, decreased pain, and augmentation of sleep. Drug-related complications included constipation, muscular hypotonia, urinary retention, erectile dysfunction, nausea, dizziness, drowsiness, hypotension and bradycardia as well as tolerance to baclofen. Some patients experienced post-spinal puncture headaches. Catheter-related problems included occlusions, breaks, punctures, and dislodgments. Superficial pump pocket infection, pocket erosion, cerebrospinal fluid (CSF) leak, post-spinal puncture headache, and meningitis were some of the procedure-related complications. Two pumps flipped and another pump valve was stuck. We conclude that long-term intrathecal baclofen by an implanted programmable pump is a safe and effective method of treating severe intractable spinal spasticity.

  14. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.

  15. Postdural puncture headache: a study with 256 Quincke needle.

    PubMed

    Singh, N Ratan; Singh, H Shanti

    2010-02-01

    The incidence of postdural puncture headache, its severity, time of onset and duration following spinal anaesthesia in female subjects using 25 gauge Quincke needles are discussed in this paper. Postdural puncture headache was seen in only 3% of the cases. The headache appeared mainly on the 1st postoperative day and was associated with nausea and vomiting in one case; and it disappeared by the 2nd to 3rd day following administration of mild analgesics and anti-emetics.

  16. [Electron microscopy of the lesions produced in the human dura mater by Quincke beveled and Whitacre needles].

    PubMed

    Reina, M A; López-García, A; de Andrés-Ibáñez, J A; Dittmann, M; Cascales, M R; del Caño, M C; Daneri, J; Zambrano, O

    1997-02-01

    Comparisons of Quincke needles and non traumatic "pencil point" needles in recent years have reported lower rates of post dural puncture headache using the later type. Our new understanding of the morphology of the human dura mater motivated us to study dural lesions caused by the Whitacre 25 G and Quincke 26 G needles, using scanning electron microscopy with the aim of determining whether there is an anatomic basis for the different outcomes. The dura mater from three fresh cadavers of individuals aged 65, 70 and 72 years were punctured 40 times at an angle of 90 degrees each time. The Whitacre 25 G needle was used for 20 punctures and the Quincke 26 G needle was used for the other 20. Half the punctures were performed with the bevel in the parallel alignment and the other half with the bevel perpendicular to the spinal column. Fifteen min after causing the punctures, specimens were fixed in solutions of glutaraldehyde phosphate buffer and dehydrated in acetone. After critical point removal of the acetone, after the specimens were treated with carbon and metallized with gold. The lesions were examined externally and internally and expressed as the ratio of area of lesion to diameter of the needle that had caused them. Whitacre needle: each lesion consisted in the superimposition of multiple damaged layers that started to close individually. After 15 min the outermost layers were 90% closed and the innermost ones had closed entirely. Layers in the arachnoid surface of the dura mater had closed from 86 to 88%, while deeper layers in the thick part had closed 97 to 98%. Quincke needle: lesions were V-shaped or half-moon shaped, much like the opening formed by a can opener, on both the external and internal surfaces. Alignment of the bevel of the needle parallel to the spinal column did not lead to a different shape of puncture. After 15 min the lesions had closed 94 to 95% on the epidural surface and 95 to 96% on the arachnoid side, a difference attributable to the retraction of the arachnoid layers over the spinal column. Non traumatic beveled dural needles, termed "pencil point needles", only partially separate dural fibers, and lesions caused by these needles develop in a more complex way. The Quincke 26G needle produced a puncture that is morphologically different from that caused by the Whitacre 25G needle, although lesions produced by both types close more than 94% after 15 min. We believe the size of the lesion caused by these needles does not explain the difference in post dural puncture headache due to loss of spinal fluid.

  17. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture

    PubMed Central

    Reina, M; Lopez, A; Badorrey, V; De Andres, J A; Martin, S

    2004-01-01

    Aims: The dural and arachnoid hole caused by lumbar puncture needles is a determining factor in triggering headaches. The aim of this study is to assess the dimensions and morphological features of the dura mater and arachnoids when they are punctured by a 22 gauge Quincke needle having its bevel either in the parallel or in the transverse position. Methods: Fifty punctures were made with 22 gauge Quincke needles in the dural sac of four fresh cadavers using an "in vitro" model especially designed for this purpose. The punctures were performed by needles with bevels parallel or perpendicular to the spinal axis and studied under scanning electron microscopy. Results: Thirty five of the 50 punctures done by Quincke needles (19 in the external surface and 16 in the internal) were used for evaluation. When the needle was inserted with its bevel parallel to the axis of the dural sac (17 of 35), the size of the dura-arachnoid lesion was 0.032 mm2 in the epidural surface and 0.037 mm2 in the subarachnoid surface of the dural sac. When the needle's bevel was perpendicular to the axis (18 of 35) the measurement of the lesion size was 0.042 mm2 for the external surface and 0.033 mm2 for the internal. There were no statistical significant differences between these results. Conclusions: It is believed that the reported lower frequency of postdural puncture headache when the needle is inserted parallel to the cord axis should be explained by some other factors besides the size of the dura-arachnoid injury. PMID:15146008

  18. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture.

    PubMed

    Reina, M A; López, A; Badorrey, V; De Andrés, J A; Martín, S

    2004-06-01

    The dural and arachnoid hole caused by lumbar puncture needles is a determining factor in triggering headaches. The aim of this study is to assess the dimensions and morphological features of the dura mater and arachnoids when they are punctured by a 22 gauge Quincke needle having its bevel either in the parallel or in the transverse position. Fifty punctures were made with 22 gauge Quincke needles in the dural sac of four fresh cadavers using an "in vitro" model especially designed for this purpose. The punctures were performed by needles with bevels parallel or perpendicular to the spinal axis and studied under scanning electron microscopy. Thirty five of the 50 punctures done by Quincke needles (19 in the external surface and 16 in the internal) were used for evaluation. When the needle was inserted with its bevel parallel to the axis of the dural sac (17 of 35), the size of the dura-arachnoid lesion was 0.032 mm(2) in the epidural surface and 0.037 mm(2) in the subarachnoid surface of the dural sac. When the needle's bevel was perpendicular to the axis (18 of 35) the measurement of the lesion size was 0.042 mm(2) for the external surface and 0.033 mm(2) for the internal. There were no statistical significant differences between these results. It is believed that the reported lower frequency of postdural puncture headache when the needle is inserted parallel to the cord axis should be explained by some other factors besides the size of the dura-arachnoid injury.

  19. Post dural puncture headache in cesarean section: comparison of 25-gauge Whitacre with 25- and 26-gauge Quincke needles.

    PubMed

    Hwang, J J; Ho, S T; Wang, J J; Liu, H S

    1997-03-01

    Our previous study showed that there were no significant differences in the incidence of post dural puncture headache (PDPH) relevant to the use of 24 to 26-gauge Quincke spinal needles in obstetric patients. Again, we were eager to know if the pencil-point spinal needle (Whitacre) would be able to decrease the incidence of PDPH compared to Quincke spinal needle. We prospectively observed 94 spinal anesthesias for cesarean section performed during the period from May 1993 to July 1995. The 25-gauge Whitacre needles were used. In practice the insertion of needle was made through median line approach and the puncture was considered eligible only in one attempt. The PDPH was observed until its disappearance, and one without PDPH had also been observed for at least one week for likelihood of delayed occurrence. The data were compared with those of our previous study regarding the use of 25- and 26-gauge Quincke needles in obstetric patients. All of the data were analyzed using the Fisher exact test. The incidence of PDPH was 1.06%. In comparison there was no significant difference from that of 25- and 26-gauge Quincke needles (3.65% and 2.06%, respective). Only one case suffered from PDPH in the Whitacre group. It was mild and relieved with bed rest and hydration. Although the difference was not statistically significant, the 25-gauge Whitacre spinal needle caused a lower incidence and less severity of PDPH than the 25- and 26-gauge Quincke needles did.

  20. Concomitant Intracranial and Lumbar Chronic Subdural Hematoma Treated by Fluoroscopic Guided Lumbar Puncture: A Case Report and Literature Review

    PubMed Central

    ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi

    2018-01-01

    A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039

  1. Transforaminal Lumbar Puncture: An Alternative Technique in Patients with Challenging Access.

    PubMed

    Nascene, D R; Ozutemiz, C; Estby, H; McKinney, A M; Rykken, J B

    2018-05-01

    Interlaminar lumbar puncture and cervical puncture may not be ideal in all circumstances. Recently, we have used a transforaminal approach in selected situations. Between May 2016 and December 2017, twenty-six transforaminal lumbar punctures were performed in 9 patients (25 CT-guided, 1 fluoroscopy-guided). Seven had spinal muscular atrophy and were referred for intrathecal nusinersen administration. In 2, CT myelography was performed via transforaminal lumbar puncture. The lumbar posterior elements were completely fused in 8, and there was an overlying abscess in 1. The L1-2 level was used in 2; the L2-3 level, in 10; the L3-4 level, in 12; and the L4-5 level, in 2 procedures. Post-lumbar puncture headache was observed on 4 occasions, which resolved without blood patching. One patient felt heat and pain at the injection site that resolved spontaneously within hours. One patient had radicular pain that resolved with conservative treatment. Transforaminal lumbar puncture may become an effective alternative to classic interlaminar lumbar puncture or cervical puncture. © 2018 by American Journal of Neuroradiology.

  2. A comparison of Espocan and Tuohy needles for the combined spinal-epidural technique for labor analgesia.

    PubMed

    Browne, Ingrid M; Birnbach, David J; Stein, Deborah J; O'Gorman, David A; Kuroda, Maxine

    2005-08-01

    When using the needle-through-needle combined spinal-epidural (CSE) technique for labor analgesia, failure to obtain cerebrospinal fluid (CSF), paresthesias, and intrathecal or intravascular migration of the catheter are of concern. Epidural needles with spinal needle apertures, such as the back-hole Espocan (ES) needles, are available and may reduce these risks. We describe the efficacy and adverse events associated with a modified epidural needle (ES) versus a conventional Tuohy needle for CSE. One-hundred parturients requesting labor analgesia (CSE) were randomized into 2 groups: 50-ES 18-gauge modified epidural needle with 27-gauge Pencan atraumatic spinal needle, 50-conventional 18-gauge Tuohy needle with 27-gauge Gertie Marx atraumatic spinal needle. Information on intrathecal or intravascular catheter placement, paresthesia on introduction of spinal needle, failure to obtain CSF through the spinal needle after placement of epidural needle, unintentional dural puncture, and epidural catheter function was obtained. No intrathecal catheter placement occurred in either group. Rates of intravascular catheter placement and unintentional dural puncture were similar between the groups. Significant differences were noted regarding spinal needle-induced paresthesia (14% ES versus 42% Tuohy needles, P = 0.009) and failure to obtain CSF on first attempt (8% ES versus 28% Tuohy needles, P < 0.02). Use of ES needles for CSE significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt. The use of modified epidural needles with a back hole for combined spinal-epidural technique significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt.

  3. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  4. The use of Quincke and Whitacre 27-gauge needles in orthopedic patients: incidence of failed spinal anesthesia and postdural puncture headache.

    PubMed

    Lynch, J; Kasper, S M; Strick, K; Topalidis, K; Schaaf, H; Zech, D; Krings-Ernst, I

    1994-07-01

    This study examined the incidence of failed spinal anesthesia and postdural puncture headache using a 27-gauge Whitacre and a 27-gauge Quincke needle in patients undergoing elective inpatient orthopedic procedures. The overall rate of failed spinal anesthesia was 8.5% [95% confidence interval (CI) = 4.6%-12.4%] (n = 17) in the Quincke group (n = 199) and 5.5% [95% CI = 2.3%-8.7%] (n = 11) in the Whitacre group (n = 199). This difference was not statistically significant. The overall incidence of postdural puncture headache (PDPH) was 0.8%; 1.1% [95% CI = 0%-2.4%] (n = 2) in the Quincke group and 0.5% [95% CI = 0%-1.5%] (n = 1) in the Whitacre group. These differences were not statistically significant. All headaches were classified as mild and resolved spontaneously with conservative management. The mean time for withdrawal of the stylet to appearance of cerebrospinal fluid was 10.8 +/- 6.9 s in the Quincke (n = 31) and 10.7 +/- 6.8 s in the Whitacre group (n = 33). These differences were not statistically significant. Our results suggest that both needles are associated with a very low incidence of PDPH and an incidence of failed anesthesia of 5.5%-8.5%.

  5. Intraoperative direct puncture and embolization (IOPE) using a glue material for spinal cord arteriovenous fistula: a case report.

    PubMed

    Shin, Hong Kyung; Suh, Dae Chul; Jeon, Sang Ryong

    2015-05-01

    Spinal arteriovenous fistula (AVF) is treated by embolization or surgery. However, transarterial embolization or surgery is difficult in rare cases when the fistula site is very complicated to access especially as in fistular nidus supplied by posterior and anterior spinal artery. We present the case which was treated with intraoperative direct puncture and embolization (IOPE) using glue material, since the usual transarterial or transvenous neurointerventional approach was difficult to embolize the AVF. A 36-year-old woman presented with progressive leg weakness and pain after a 20-year history of lower back pain. She had pelvic and spinal AVF combined with arteriovenous malformation (AVM). Despite prior treatment of the pelvic lesion with radiotherapy and coil embolization, the spinal lesion persisted and caused repeated subarachnoid hemorrhages. A spinal angiogram revealed a tortuous and long feeder of the AVF which had growing venous sac, as well as AVM. Two embolization trials failed because of the long tortuosity and associated anterior spinal artery. Four months later, drastic leg weakness and pain occurred, and IOPE was performed using a glue material. The subsequent recovery of the patient was rapid. One month later, the use of a strong opioid could be discontinued, and the patient could walk with aid. A follow-up spinal angiogram revealed that the venous sac of the AVF had disappeared. In spinal AVF which is not feasible to access by usual intervention approach and to dissect surgically, IOPE with glue material can be considered for the treatment.

  6. Spinal anesthesia for laparoscopic cholecystectomy: Thoracic vs. Lumbar Technique

    PubMed Central

    Imbelloni, Luiz Eduardo

    2014-01-01

    Aims: In our group, after a study showing that spinal anesthesia is safe when compared with general anesthesia, spinal anesthesia has been the technique of choice for this procedure. This is a prospective study with all patients undergoing LC under spinal anesthesia in our department since 2007. Settings and Design: Prospective observational. Materials and Methods: From 2007 to 2011, 369 patients with symptoms of colelithiasis, laparoscopic cholecystectomy were operated under spinal anesthesia with pneumoperitoneum and low pressure CO2. We compared 15 mg of hyperbaric bupivacaine and lumbar puncture with 10 or 7.5 mg of hyperbaric bupivacaine thoracic puncture, all with 25 μg fentanyl until the sensory level reached T3. Intraoperative parameters, post-operative pain, complications, recovery, patient satisfaction, and cost were compared between both groups. Statistical Analysis Used: Means were compared by ANOVA or Kruskal-Wallis test, the percentages of the Chi-square test or Fisher's exact test when appropriate. Time of motor and sensory block in spinal anesthesia group was compared by paired t test or Mann-Whitney test. Differences were considered significant when P ≤ 0.05, and for comparisons of mean pain visual scale, we employed the Bonferroni correction applied to be considered significant only with P ≤ 0.0125 Results: All procedures were completed under spinal anesthesia. The use of lidocaine 1% was successful in the prevention of shoulder pain in 329 (89%) patients. There were significant differences in time to reach T3, obtaining 15 mg > 10 mg = 7.5 mg. There is a positive correlation between the dose and the incidence of hypotension. The lowest doses gave a decrease of 52.2% in the incidence of hypotension. There was a positive correlation between the dose and duration of sensory and motor block. Sensory block was almost twice the motor block at all doses. With low doses, 60% of patients went from table to stretcher. Satisfaction occurred in 99% of patients. Conclusions: Laparoscopic cholecystectomy can be performed successfully under spinal anesthesia with low-pressure pneumoperitoneum of CO2. The use of thoracic puncture and low doses of hyperbaric bupivacaine provided better hemodynamic stability, less hypotension, and shorter duration of sensory and motor blockade than lumbar spinal anesthesia with conventional doses. PMID:25422604

  7. Whitacre or Quincke needles--does it really matter.

    PubMed

    Eriksson, A L; Hallén, B; Lagerkranser, M; Persson, E; Sköldefors, E

    1998-01-01

    Postdural puncture headache (PDPH) and backache are well known complications of spinal anaesthesia. The incidence of PDPH may be significant in young people (< 50 years). The present study was undertaken in order to compare the utility and complication rate of the Whitacre and Ouincke spinal needles. During three years all patients who could comply, and who were to undergo spinal anaesthesia at the Department were asked to join this quality control study. Each one received a questionnaire including questions about discomfort and other possible side effects attributed to spinal anaesthesia. In each case, an extended anaesthetic record was filled out by the anaesthesiologist. About 50 anaesthesiologists at different educational levels were involved. The study includes 2598 cases, of which questionnaires were returned by 66%. Needles of the 25 G gauge size were used in over 90% of the cases. Multiple skin punctures were required more frequently in the Quincke than in the Whitacre group (P < 0.01). The number of insufficient blocks was also higher in the Quincke group (P < 0.01). There was a higher incidence of backache in the Quincke group (P < 0.05). In patients under 50 years, PDPH was more frequent following use of the Quincke needle (P < 0.05), whereas no difference between the needles in this regard was found among those over 50 years (P > 0.05). For routine clinical use the Whitacre needle appears to be associated with better performance and increased reliability. In younger patients the Whitacre needle have the additional advantage of decreasing the risk of postdural puncture headache.

  8. Do pencil-point spinal needles decrease the incidence of postdural puncture headache in reality? A comparative study between pencil-point 25G Whitacre and cutting-beveled 25G Quincke spinal needles in 320 obstetric patients.

    PubMed

    Pal, Anirban; Acharya, Amita; Pal, Nidhi Dawar; Dawn, Satrajit; Biswas, Jhuma

    2011-01-01

    Postdural puncture headache (PDPH) is a distressing complication of the subarachnoid block. The previous studies conducted, including the recent ones, do not conclusively prove that pencil-point spinal needles decrease the incidence of PDPH. In this study, we have tried to find out whether a pencil-point Whitacre needle is a better alternative than the classic cutting beveled, commonly used, Quincke spinal needle, in patients at risk of PDPH. Three hundred and twenty obstetric patients, 20-36 years of age, ASA I and II, posted for Cesarean section under subarachnoid block, were randomly assigned into two groups W and Q, where 25G Whitacre and 25G Quincke spinal needles were used, respectively. The primary objective of the study was to find out the difference in incidence of PDPH, if any, between the two groups, by using the t test and Chi square test. The incidence of PDPH was 5% in group W and 28.12% in group Q, and the difference in incidence was statistically significant (P<0.001). The pencil-point 25G Whitacre spinal needle causes less incidence of PDPH compared to the classic 25G Quincke needle, and is recommended for use in patients at risk of PDPH.

  9. Do pencil-point spinal needles decrease the incidence of postdural puncture headache in reality? A comparative study between pencil-point 25G Whitacre and cutting-beveled 25G Quincke spinal needles in 320 obstetric patients

    PubMed Central

    Pal, Anirban; Acharya, Amita; Pal, Nidhi Dawar; Dawn, Satrajit; Biswas, Jhuma

    2011-01-01

    Background: Postdural puncture headache (PDPH) is a distressing complication of the subarachnoid block. The previous studies conducted, including the recent ones, do not conclusively prove that pencil-point spinal needles decrease the incidence of PDPH. In this study, we have tried to find out whether a pencil-point Whitacre needle is a better alternative than the classic cutting beveled, commonly used, Quincke spinal needle, in patients at risk of PDPH. Materials and Methods: Three hundred and twenty obstetric patients, 20-36 years of age, ASA I and II, posted for Cesarean section under subarachnoid block, were randomly assigned into two groups W and Q, where 25G Whitacre and 25G Quincke spinal needles were used, respectively. The primary objective of the study was to find out the difference in incidence of PDPH, if any, between the two groups, by using the t test and Chi square test. Results: The incidence of PDPH was 5% in group W and 28.12% in group Q, and the difference in incidence was statistically significant (P<0.001). Conclusion: The pencil-point 25G Whitacre spinal needle causes less incidence of PDPH compared to the classic 25G Quincke needle, and is recommended for use in patients at risk of PDPH. PMID:25885381

  10. Continuous spinal anesthesia for lower limb surgery: a retrospective analysis of 1212 cases

    PubMed Central

    Lux, Eberhard Albert

    2012-01-01

    Background Continuous spinal anesthesia is a very reliable and versatile technique for providing effective anesthesia and analgesia. However, the incidence of possible complications, including postdural puncture headache or neurological impairment, remains controversial. Therefore, the aim of the present retrospective study was to analyze a large number of patients for the incidence of adverse events after continuous spinal anesthesia with a microcatheter. Methods This retrospective study was conducted on 1212 patients who underwent surgery of the lower extremities with continuous spinal anesthesia, which was administered with 22-gauge Quincke spinal needles and 28-gauge microcatheters. Sociodemographic and clinical data were available from the patient records, and data on headaches and patient satisfaction were drawn from a brief postoperative patient questionnaire. Results The patient population included 825 females (68%) and 387 males; the median age was 61 (56–76). The types of operations performed were 843 hip prostheses, 264 knee prostheses, and 105 other leg operations. No major complications were observed in any of these patients. Tension headaches were experienced by 190 (15.7%) patients, but postdural puncture headaches were reported by only 18 (1.5%) patients. Nearly all patients (98.4%) were satisfied with continuous spinal anesthesia and confirmed that they would choose this kind of anesthesia again. Conclusion Based on the findings of this large data analysis, continuous spinal anesthesia using a 28-gauge microcatheter appears to be a safe and appropriate anesthetic technique in lower leg surgery for aged patients. PMID:23204868

  11. Echodense spinal subarachnoid space in neonates with progressive ventricular dilatation: a marker of noncommunicating hydrocephalus.

    PubMed

    Rudas, G; Almássy, Z; Papp, B; Varga, E; Méder, U; Taylor, G A

    1998-10-01

    Our purpose was to evaluate the frequency and clinical significance of echogenic debris in the spinal subarachnoid space of neonates at risk for progressive ventricular dilatation. Spinal sonography was performed on 15 neonates with severe intracranial hemorrhage (n = 10) or bacterial meningitis (n = 5). Spinal sonography also was performed on 16 control neonates. Images were analyzed for the presence and location of echogeric debris within the thoracolumbar subarachnoid space. Lumbar punctures were performed on all 31 neonates, and CSF was analyzed for cell count and protein content. Ten of 15 neonates required ventricular drainage procedures. Progressive ventricular dilatation occurred in 11 of 15 neonates with intracranial hemorrhage or meningitis. Echogenic debris was present in the thoracolumbar subarachnoid space on spinal sonography in every neonate with progressive ventricular dilatation compared with none of the 16 control neonates (p < .0001 by chi-square analysis). In addition, the 11 neonates with echogenic subarachnoid space had significantly higher protein and RBC contents in the lumbar CSF (p < .04). Echogenic subarachnoid space revealed by sonography is associated with progressive ventricular dilatation after severe intracranial hemorrhage or bacterial meningitis and is caused by high protein and RBC contents in the subarachnoid space. This finding may be helpful in identifying neonates who will not benefit from serial lumbar punctures for treatment of hydrocephalus.

  12. Laparoscopic cholecystectomy under spinal anesthesia: comparative study between conventional-dose and low-dose hyperbaric bupivacaine

    PubMed Central

    Imbelloni, Luiz Eduardo; Sant’Anna, Raphael; Fornasari, Marcos; Fialho, José Carlos

    2011-01-01

    Background Laparoscopic cholecystectomy has the advantages of causing less postoperative pain and requiring a short hospital stay, and therefore is the treatment of choice for cholelithiasis. This study was designed to compare spinal anesthesia using hyperbaric bupivacaine given as a conventional dose by lumbar puncture or as a low-dose by thoracic puncture. Methods A total of 140 patients with symptomatic gallstone disease were randomized to undergo laparoscopic cholecystectomy with low-pressure CO2 pneumoperitoneum under spinal anesthesia using either conventional lumbar spinal anesthesia (hyperbaric bupivacaine 15 mg and fentanyl 20 mg) or low-dose thoracic spinal anesthesia (hyperbaric bupivacaine 7.5 mg and fentanyl 20 μg). Intraoperative parameters, postoperative pain, complications, recovery time, and patient satisfaction at follow-up were compared between the two treatment groups. Results All procedures were completed under spinal anesthesia, with no cases needing conversion to general anesthesia. Values for time for block to reach the T3 dermatomal level, duration of motor and sensory block, and hypotensive events were significantly lower with low-dose bupivacaine. Postoperative pain was higher for low-dose hyperbaric bupivacaine at 6 and 12 hours. All patients were discharged after 24 hours. Follow-up 1 week postoperatively showed all patients to be satisfied and to be keen advocates of spinal anesthesia. Conclusion Laparoscopic cholecystectomy can be performed successfully under spinal anesthesia. A small dose of hyperbaric bupivacaine 7.5 mg and 20 μg fentanyl provides adequate spinal anesthesia for laparoscopy and, in comparison with hyperbaric bupivacaine 15% and fentanyl 20 μg, causes markedly less hypotension. The low-dose strategy may have an advantage in ambulatory patients because of the earlier recovery of motor and sensory function and earlier discharge. PMID:22915892

  13. A Case of Prolonged Delayed Postdural Puncture Headache in a Patient with Multiple Sclerosis Exacerbated by Air Travel

    PubMed Central

    Porhomayon, Jahan; Zadeii, Gino; Yarahamadi, Alireza; Nader, Nader D.

    2013-01-01

    The developments of new spinal needles and needle tip designs have reduced the incidence of postdural puncture headache (PDPH). Although it is clear that reducing the loss of CSF leak from dural puncture reduces the headache, there are areas regarding the pathogenesis, treatment, and prevention of PDPH that remain controversial. Air travel by itself may impose physiological alteration in central nervous system that may be detrimental to patients with PDPH. This case report highlights a case of a young female patient who suffered from a severe incapacitating PDPH headache during high-altitude flight with a commercial jet. PMID:23401803

  14. High incidence of post-dural puncture headache in patients with spinal saddle block induced with Quincke needles for anorectal surgery: a randomised clinical trial.

    PubMed

    Schmittner, Marc D; Terboven, Tom; Dluzak, Michael; Janke, Andrea; Limmer, Marc E; Weiss, Christel; Bussen, Dieter G; Burmeister, Marc A; Beck, Grietje C

    2010-06-01

    Spinal saddle block represents nearly the ideal anaesthesia technique for anorectal surgery. Post-dural puncture headache (PDPH) is a dreaded complication but can be decreased by the use of non-cutting spinal needles to rates less than 1%. Though, cutting Quincke type needles are still widely used for economic reasons, leading to a higher rate of PDPH. We performed this study to demonstrate a reduction of PDPH by the use of very small 29-G compared with commonly used 25-G Quincke type spinal needles. Two hundred sixteen adult patients (male/female, 19-83 years, ASA status I-III) were randomised 1:1 to groups, in which either a 25-G or a 29-G Quincke type spinal needle was used for a spinal saddle block. The incidence of PDPH was assessed during 1 week after surgery. Thirty-nine of 216 patients developed PDPH but there was no difference between the two needle sizes (25-G, n = 18/106 vs. 29-G, n = 21/110, p = 0.6870). Women suffered significantly more from PDPH than men (23/86 vs. 16/130, p = 0.0069). Ambulatory patients had a later onset of PDPH than in-patients (24 h [0.5-72] vs. 2 h [0.2-96], p = 0.0002) and the headache was more severe in these patients (NRS 7 [2-10] vs. NRS 3 [1-8], p = 0.0009). The use of 29-G compared with 25-G Quincke needles led to no reduction of PDPH and is considerably higher compared with data from pencil-point needles. The use of non-cutting or pencil-point spinal needles should become the standard for performing spinal saddle block.

  15. Postdural puncture headache: a randomized prospective comparison of the 24 gauge Sprotte and the 27 gauge Quincke needles in young patients.

    PubMed

    Wiesel, S; Tessler, M J; Easdown, L J

    1993-07-01

    This study was designed to compare the frequency of postdural puncture headaches (PDPH) using the 24 gauge Sprotte and the 27 gauge Quincke spinal needles in a population of patients less than 45 yr of age undergoing spinal anaesthesia for non-obstetrical surgery. Patients were randomly assigned to receive spinal anaesthesia with either the 24 gauge Sprotte spinal needle (n = 46) or the 27 gauge Quincke spinal needle (n = 47). Patients were interviewed on either postoperative day one or two and on postoperative day three. A PDPH was defined as a headache involving the occipital or frontal areas that is made worse when assuming either the sitting or standing position. Ninety-three patients were included in the analysis of data. The overall incidence of PDPH was 14% (13 of 93), and no difference was found between the Sprotte (15.2%) and Quincke (12.8%) needles. The distribution of the PDPHs by severity was not different between the two groups. None of the 13 patients with PDPHs required on epidural blood patch for relief of symptoms. Both the Sprotte needle and the Quincke needles were judged as easy to use and both required the same number of attempts in order to locate cerebrospinal fluid (first attempt successful: 73.9% versus 66%). Neither patient satisfaction nor the acceptability of spinal anaesthesia for a future procedure was adversely affected by the occurrence of a PDPH. The results of this study suggest that the risk of PDPH after spinal anaesthesia in young patients is similar using either the 24 gauge Sprotte or the 27 gauge Quincke spinal needle.

  16. Blood patch rates after lumbar puncture with Whitacre versus Quincke 22- and 20-gauge spinal needles.

    PubMed

    Hatfield, Malcolm K; Handrich, Stephen J; Willis, Jeffrey A; Beres, Robert A; Zaleski, George X

    2008-06-01

    The objective of our study was to compare the incidence of blood patch as the best objective indicator of postdural puncture headache after elective fluoroscopic lumbar puncture with the use of a 22-gauge Whitacre (pencil point) needle versus standard 22- and 20-gauge Quincke (bevel-tip) needles and to determine the best level of puncture. The records of 724 consecutive patients who were referred to St. Mary's Medical Center department of radiology for fluoroscopic lumbar puncture from January 2003 through April 2007 were retrospectively reviewed. Emergency requests (191) were discarded along with those for patients with clinical signs of pseudotumor cerebri (21), normal pressure hydrocephalus (3), and failed attempts (4). The collective total was 505 elective lumbar punctures. The blood patch rate for the 22-gauge Whitacre needle was 4.2%. The result for the 22-gauge Quincke point needle was 15.1% whereas that for the 20-gauge Quincke point needle was 29.6%. In addition, the level of puncture showed a blood patch rate that increased as the level of lumbar puncture lowered. The highest level of lumbar puncture was L1-L2 with the lowest recorded level being L5-S1. The Whitacre needle is associated with a significantly lower incidence of blood patch rate after lumbar puncture. The highest level of puncture (L1-L2) also provides the lowest level of blood patch rate.

  17. Technological advances and changing indications for lumbar puncture in neurological disorders.

    PubMed

    Costerus, Joost M; Brouwer, Matthijs C; van de Beek, Diederik

    2018-03-01

    Technological advances have changed the indications for and the way in which lumbar puncture is done. Suspected CNS infection remains the most common indication for lumbar puncture, but new molecular techniques have broadened CSF analysis indications, such as the determination of neuronal autoantibodies in autoimmune encephalitis. New screening techniques have increased sensitvity for pathogen detection and can be used to identify pathogens that were previously unknown to cause CNS infections. Evidence suggests that potential treatments for neurodegenerative diseases, such as Alzheimer's disease, will rely on early detection of the disease with the use of CSF biomarkers. In addition to being used as a diagnostic tool, lumbar puncture can also be used to administer intrathecal treatments as shown by studies of antisense oligonucleotides in patients with spinal muscular atrophy. Lumbar puncture is generally a safe procedure but complications can occur, ranging from minor (eg, back pain) to potentially devastating (eg, cerebral herniation). Evidence that an atraumatic needle tip design reduces complications of lumbar puncture is compelling, and reinforces the need to change clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Subarachnoid and basal cistern navigation through the sacral hiatus with guide wire assistance.

    PubMed

    Layer, Lauren; Riascos, Roy; Firouzbakht, Farhood; Amole, Adewumi; Von Ritschl, Rudiger; Dipatre, Pier; Cuellar, Hugo

    2011-07-01

    Intraspinal navigation with catheters and fiberscopes has shown feasible results for diagnosis and treatment of intraspinal and intracranial lesions. The most common approach, lumbar puncture, has allowed access to the spinal cord, however, coming with the difficulties of fiberscope damage and decreased torque for guidance. Our objective in this study is to allow an alternate access, the sacral hiatus, with guide wire assistance into the subarachnoid and intracranial structures, while easing the angle of entry and increasing torque. We advanced catheters with guide wire and fluoroscopy assistance into the sacral hiatus of three cadavers. After entry, the thecal sac was punctured and the catheter with guide wire was advanced rostrally until positioned in the basal cisterns of the brain. We confirmed catheter placement with contrast injection, autopsy, and dissection. In our study, the sacral hiatus was easily accessed, but resistance was found when attempting to puncture the thecal sac. The advancement of the catheter with guide wire assistance glided easily rostrally until some mild resistance was discovered at entry into the foramen magnum. With redirection, all catheters passed with ease into the basal cisterns. Positioning was confirmed with contrast injection with fluoroscopy evidence, autopsy, and dissection. There was no macroscopic or microscopic evidence of damage to the spinal roots, spinal cord, or cranial nerves. The sacral hiatus with guide wire assistance is an accessible conduit for uncomplicated entry into the subarachnoid and basal cistern space without damaging surrounding structures.

  19. [Rare and severe complication of spinal anesthesia: bacterial meningitis (about a case and literature review)].

    PubMed

    Chouaib, Naoufal; Jidane, Said; Rafai, Mostafa; Belkouch, Ahmed; Zidouh, Saad; Belyamani, Lahcen

    2017-01-01

    Spinal anesthesia (SA) is the first locoregional anesthesia. It can cause side effects and carry risks that need to be avoided, prevented or treated early. We here report the case of a female patient operated under spinal anesthesia who had intense headache associated with nausea and vomiting evolving in the context of fever within a few days after surgeryLumbar puncture showed cloudy liquid revealing Gram + cocci on direct examination. This allowed the diagnosis of bacterial meningitis. Patient's evolution was favorable after antibiotic therapy.

  20. Use of a 22-gauge Whitacre needle to reduce the incidence of side effects after lumbar myelography: a prospective randomised study comparing Whitacre and Quincke spinal needles.

    PubMed

    Pedersen, O N

    1996-01-01

    In a prospective study lumbar iohexol myelography was performed in 107 consecutive patients, randomised for lumbar puncture with a Quincke or Whitacre spinal needle. All patients answered a questionnaire about possible side effects. Data from 100 patients (58 men, 42 women) were evaluated. In the Quincke group (n = 53), 23 (43%) reported no side effects. In the 30 patients who reported various side effects, post-dural puncture headache (PDPH) occurred in 22 (42%), of whom 9 had mild, 6 moderate and 7 (13%) severe cephalalgia, 18 (34%) reported increased low back pain/sciatica, 5 nausea and 7 dizziness. In the Whitacre group (n = 47), 33 (70%) had no side effects. PDPH was reported by 9 patients (19%), of whom 2 had mild, 6 moderate and only 1 (2%) severe cephalalgia, 4 (9%) reported increased low back pain/sciatica, 5 nausea and 4 dizziness. The conclusion drawn from this study is that lumbar myelography performed with the Whitacre spinal needle reduces postspinal side effects.

  1. Postdural puncture headache and back pain after spinal anesthesia with 27-gauge Quincke and 26-gauge Atraucan needles.

    PubMed

    Schultz, A M; Ulbing, S; Kaider, A; Lehofer, F

    1996-01-01

    The purpose of this study was to determine whether the 26-gauge Atraucan needle shows any benefit on the incidence of postdural puncture headache (PDPH) and back pain as compared with the 27-gauge Quincke needle. We investigated 388 patients, 171 men and 217 women, who were receiving spinal anesthesia for subumbilical surgery. We compared spinal anesthesia via the 27-gauge Quincke needle in 202 patients (group Q) and via the 26-gauge Atraucan needle in 186 patients (group A). The incidence of PDPH was 2.97% (6 of 202) in group Q and 2.69% (5 of 186) in group A. The incidence of back pain was 4.95% (10 of 202) in group Q and 5.91% (11 of 186) in group A. There was no statistically significant association of needle type, age, or sex with the incidence of PDPH and back pain. Both needles are associated with very low incidences of PDPH and back pain, which are not affected by which needle is chosen.

  2. Effect of dexamethasone on the frequency of postdural puncture headache after spinal anesthesia for cesarean section: a double-blind randomized clinical trial.

    PubMed

    Yousefshahi, Fardin; Dahmardeh, Alireza Rahat; Khajavi, Mohammadreza; Najafi, Atabak; Khashayar, Patricia; Barkhordari, Khosro

    2012-12-01

    In this study, we evaluated the effect of dexamethasone used as a prophylaxis for nausea and vomiting on the incidence of postdural puncture headache (PDPH) in pregnant women receiving spinal anesthesia for cesarean section. In a prospective, randomized, double-blind, placebo-controlled study, 372 women under spinal anesthesia received 8 mg of dexamethasone or placebo intravenously just after the umbilical cord was clamped. The rate of PDPH and correlated risk factors were evaluated. The prevalence of nausea and vomiting in the dexamethasone and placebo groups was 54.4 and 51.7%, respectively. There was no statistically meaningful difference between the results (P value = 0.673). The overall incidence rate of PDPH was 10.8%, with 28 cases from the dexamethasone group compared with 11 subjects from the placebo group (P value = 0.006). This effect was most prominent on the first day (P value = 0.046) and disappeared on the second day after spinal anesthesia (P value = 0.678). Prophylactic treatment with 8 mg of dexamethasone not only increases the severity and incidence of PDPH, but is also ineffective in decreasing the prevalence of intra-operative nausea and vomiting during cesarean section. The treatment is a significant risk factor for the development of PDPH.

  3. Cerebrospinal Fluid (CSF) Analysis

    MedlinePlus

    ... Internet]. Allina Health; c2017. Cerebrospinal fluid IgG measurement, quantitative [updated 2016 Mar 29; cited 2017 Oct 22]; [ ... Clinic [Internet]. Mayo Foundation for Medical Education and Research; c1998–2017. Lumbar puncture (spinal tap): Risks; 2014 ...

  4. Collecting Samples for Testing

    MedlinePlus

    ... one or more hours to avoid a potential post-test spinal headache. The lumbar puncture procedure usually takes ... View sources NOTE: This article is based on research that ... of the Lab Tests Online Editorial Review Board . This article is periodically ...

  5. Electron Microscopy of Dural and Arachnoid Disruptions After Subarachnoid Block.

    PubMed

    Reina, Miguel Angel; Puigdellívol-Sánchez, Anna; Gatt, Stephen P; De Andrés, José; Prats-Galino, Alberto; van Zundert, André

    It has been customary to attribute postdural puncture headache (PDPH) incidence and severity to size and nature of the dural hole produced during major neuraxial blockade or diagnostic dural puncture. Needle orientation in relation to the direction of dural fibers was thought to be of importance because of the propensity for horizontal bevel placement to cause cutting rather than splitting of the dural fibers. In vitro punctures of stringently quality-controlled human dural sac specimens were obtained with 27-gauge (27G) Whitacre needle (n = 33), with 29G Quincke used parallel to the spinal axis (n = 30), and with 29G Quincke in perpendicular approach (n = 40). The samples were studied with a scanning electron microscope, and the perimeter, appearance, and area (%) of the lesion were calculated. When using small 27G to 29G needles, neither needle tip characteristics nor needle orientation had a substantial bearing on the damage to dural fibers in the dural lesion. Of ultimate importance was the characteristic and size of the hole in the arachnoid. Arachnoid layer lesions produced by different types of spinal needles were not markedly different. Accepted theories of the etiology of PDPH need to be revised. This article marks the first time that arachnoid layer damage has been quantified. Dural fibers tend to have sufficient "memory" to close back the hole created by a spinal needle, whereas arachnoid has diminished capacity to do so. The pathogenesis of PDPH and its resolution algorithm are a far more complex process that involves many more "stages" of development than hitherto imagined.

  6. Inadvertent intrathecal injection of labetalol in a patient undergoing post-partum tubal ligation.

    PubMed

    Balestrieri, P J; Hamza, M S; Ting, P H; Blank, R S; Grubb, C T

    2005-10-01

    After receiving a continuous spinal anesthetic for labor following an inadvertent dural puncture with a 17-gauge epidural needle, a morbidly obese parturient underwent post-partum tubal ligation 12 h after vaginal delivery. The patient received a total of 2 mL of 0.75% hyperbaric bupivacaine for the surgery. In response to moderate hypertension the patient received intravenous labetalol hydrochloride 20 mg. She subsequently was inadvertently administered approximately 15 mg of labetalol through the spinal catheter. The spinal catheter was removed immediately after the procedure. She suffered no apparent adverse neurologic effects.

  7. [Effect of tiapride on the side effects of cerebrospinal fluid depletions in spinal puncture, pneumoencephalography and air myelography].

    PubMed

    Zenglein, J P; Baldauf, E; Wasser, P h

    1978-04-01

    The authors report their experience of the treatment post-cerebrospinal fluid loss syndrom, following subtraction by lumbar puncture, pneumoencephalography and air myelography. The study of 70 patients, divided in two equal groups, one receiving classic therapy, one receiving tiapride, a new molecule of original conception, lead to emphasize the interest of this drug. Tolerance in general is good, despite the administration of high doses and effects on the syndrom are positive and remarkable in preventive and curative treatment.

  8. [Possibility of cauda equina nerve root damage from lumbar punctures performed with 25-gauge Quincke and Whitacre needles].

    PubMed

    Reina, M A; López, A; Villanueva, M C; De Andrés, J A; Martín, S

    2005-05-01

    To assess the possibility of puncturing nerve roots in the cauda equina with spinal needles with different point designs and to quantify the number of axons affected. We performed in vitro punctures of human nerve roots taken from 3 fresh cadavers. Twenty punctures were performed with 25-gauge Whitacre needles and 40 with 25-gauge Quincke needles; half the Quincke needle punctures were carried out with the point perpendicular to the root and the other half with the point parallel to it. The samples were studied by optical and scanning electron microscopy. The possibility of finding the needle orifece inserted inside the nerve was assessed. On a photographic montage, we counted the number of axons during a hypothetical nerve puncture. Nerve roots used in this study were between 1 and 2.3 mm thick, allowing the needle to penetrate the root in the 52 samples studied. The needle orifice was never fully located inside the nerve in any of the samples. The numbers of myelinized axons affected during nerve punctures 0.2 mm deep were 95, 154, and 81 for Whitacre needles, Quincke needles with the point held perpendicular, or the same needle type held parallel, respectively. During punctures 0.5 mm deep, 472, 602, and 279 were affected for each puncture group, respectively. The differences in all cases were statistically significant. It is possible to achieve intraneural puncture with 25-gauge needles. However, full intraneural placement of the orifice of the needle is unlikely. In case of nerve trauma, the damage could be greater if puncture is carried out with a Quincke needle with the point inserted perpendicular to the nerve root.

  9. Intraoperative Adductor Canal Block for Augmentation of Periarticular Injection in Total Knee Arthroplasty: A Cadaveric Study.

    PubMed

    Pepper, Andrew M; North, Trevor W; Sunderland, Adam M; Davis, Jason J

    2016-09-01

    Function is often sacrificed for pain control after total knee arthroplasty. Motor-sparing blocks, including adductor canal block (ACB) and periarticular injection (PAI), have gained interest to address this compromise. Our study evaluates the anatomic feasibility, accuracy, and safety of intraoperative ACB as an adjunct to PAI by analyzing 3 different injection orientations and needle configurations. Eleven cadaveric knees underwent a standard medial parapatellar arthrotomy. Blunt dissection through the suprapatellar recess was performed. Using a 10-mL syringe, various colors of dyed liquid gelatin were injected toward the proximal and distal adductor canal (AC) using 3 needle configurations. Medial dissection of the knee for each specimen was performed. The position of each needle and location of injected dye was identified and described relative to the AC. Accuracy of each injection orientation and/or needle configuration was different: 86% for a blunt needle in the distal AC, 57% for blunt needle in the proximal AC, and 14% for a spinal needle in the proximal AC. Puncture of the femoral artery was observed with the spinal needle 43% of the time and had the closest average proximity to the femoral artery with a distance of 5.9 mm. There were no vascular punctures using blunt needles, and the average distance from the femoral artery with proximal and distal orientation was 10.2 mm and 15.4 mm, respectively. Intraoperative ACB augmentation of PAI appears to be anatomically feasible and safe. There was decreased accuracy and increased risk of vascular puncture using a 3.5-inch spinal needle. A blunt 1.5-inch needle directed toward the distal AC had the highest accuracy while minimizing vascular injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Active extravasation of gadolinium-based contrast agent into the subdural space following lumbar puncture.

    PubMed

    Kothari, Pranay D; Hanser, Evelyn M; Wang, Harrison; Farid, Nikdokht

    2016-01-01

    A 38year-old male presented with cauda equina syndrome following multiple lumbar puncture attempts. Lumbar spine magnetic resonance imaging (MRI) showed a subdural hematoma and an area of apparent contrast enhancement in the spinal canal on sagittal post-contrast images. Axial post-contrast images obtained seven minutes later demonstrated an increase in size and change in shape of the region of apparent contrast enhancement, indicating active extravasation of the contrast agent. This is the first reported case of active extravasation of gadolinium-based contrast agent in the spine. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Study of the damage rate caused by intervertebral foramen type inside and outside and the pass of the intervertebral DRG RF puncture way.

    PubMed

    Sun, Jiashu; Zhang, Haitao

    2014-09-01

    This paper was to analyze and contrast the damage rate on the thoracic segment different position of the dorsal root ganglion(dorsal root ganglion, DRG) caused by different puncture path in radiofrequency ablation, thus the best RF target way for the thoracic segment of different types of DRG was confirmed. According to the difference of puncture and ablation damage way, 14 segmental spinal specimens were randomly divided into three groups, and then conducted DRG radiofrequency damage on percutaneous puncture path according to the type of DRG position.The damage effect of different puncture path by the judgment standard of the result of pathology analyzed. The experiment showed that RF damage of group A were 72.58 ± 18.88%, 54.16 ± 24.84% and 32.85 ± 28.11%; that of group B were 771.86 ± 15.15% and 72.02 ± 17.86%, 57.14 ± 18.02% and 52.47 ± 20.64%, 68.75 ± 14.63% and 71.78 ± 16.00%; and that of group C were 82.46 ± 14.10%, 81.53 ± 11.81% and 80.83 ± 13.33%. It was concluded that the singleness of DRG puncture route is one of the important reasons for the poor thoracic segments DRG radiofrequency (RF) ablation effect. While according to the type of DRG different positions with double joint puncture path can significantly improve the rate of DRG RF damage.

  12. Premedication with granisetron reduces shivering during spinal anaesthesia in children.

    PubMed

    Eldaba, Ahmed A; Amr, Yasser M

    2012-01-01

    This study evaluates the effect of prophylactic granisetron on the incidence of postoperative shivering after spinal anaesthesia in children. Eighty children, American Society of Anesthesiologists physical status I to II and aged two to five years were scheduled for surgery of the lower limb under spinal anaesthesia. The children were randomised to receive 10 µg/kg granisetron diluted in 10 ml saline 0.9% intravenously (group 1, n=40) or placebo (10 ml 0.9% saline, group 2, n=40) to be given over five minutes just before spinal puncture. Shivering, core temperature and the levels of motor and sensory block were assessed. No patients shivered in group 1. However, six patients shivered in Group 2 (P=0.025). There were no significant differences in the other measured variables between the groups. Granisetron is an effective agent to prevent shivering after spinal anaesthesia in children from two to five years of age.

  13. A bandpass filter for the enhancement of an X-ray reconstruction of the tissue in the spinal canal

    NASA Technical Reports Server (NTRS)

    Reed, I. S.; Glenn, W. V.; Kwoh, Y. S.; Truong, T. K.

    1980-01-01

    In this communication, a new bandpass reconstruction filter is developed to partially remove the low spatial frequencies of the bone and the soft tissue in an X-ray reconstruction of a lumbar spine. This partial removal of the low frequencies suppresses the bony vertebral body and the soft tissue components within the projections of actual clinical data. It also has the effect of enhancing the sharp edges of the fatty tissue surrounding the spinal cord region. The intent of this effort is to directly visualize the spinal cord without the need for water-soluble contrast (e.g., metrizamide) to be installed through lumbar punctures.

  14. A 5-Year Audit of Accidental Dural Punctures, Postdural Puncture Headaches, and Failed Regional Anesthetics at a Tertiary-Care Medical Center

    PubMed Central

    Singh, Sukhdip; Chaudry, Shagufta Y.; Phelps, Amy L.; Vallejo, Manuel C

    2009-01-01

    Obstetric anesthesia-related complications occur as a result of labor epidural or spinal placement. The purpose of this continuous quality-improvement audit was to review the occurrence of accidental dural punctures (ADPs), postdural puncture headaches (PDPHs), and failed regional anesthetics at an academic tertiary-care medical center over a 5-year period. Obstetric anesthesia complications contained in three databases consisting of ADPs, PDPHs, and failed regional anesthetics were matched to a perinatal database, with no complications serving as controls. Of the 40,894 consecutive parturients, there were 765 documented complications. Complication rates were 0.73% (95% CI: 0.65–0.82) for ADP, 0.49% (95% CI: 0.43–0.56) for PDPH, and 0.65% (95% CI: 0.57–0.73) for failed regional anesthetic. When compared to the no complication group, factors associated with obstetric anesthesia complications included increased weight and BMI (p < 0.01), epidural block (p < 0.01), and vaginal delivery (p< 0.01). PMID:19649510

  15. Epidural analgesia complicated by dural ectasia in the Marfan syndrome

    PubMed Central

    Gray, Chelsea; Hofkamp, Michael P.; Noonan, Patrick T.; McAllister, Russell K.; Pilkinton, Kimberly A.; Diao, Zhiying

    2016-01-01

    Patients with the Marfan syndrome are considered to be high risk during pregnancy and warrant a complete multidisciplinary evaluation. One goal is to minimize hemodynamic fluctuations during labor since hypertensive episodes may result in aortic dissection or rupture. Although they may prevent these complications, neuraxial techniques may be complicated by dural ectasia. The case of a parturient with the Marfan syndrome and mild dural ectasia is presented. During attempted labor epidural placement, unintentional dural puncture occurred. A spinal catheter was used for adequate labor analgesia, and a resultant postdural puncture headache was alleviated by an epidural blood patch under fluoroscopic guidance. PMID:27695168

  16. [Paresthesia and spinal anesthesia for cesarean section: comparison of patient positioning].

    PubMed

    Palacio Abizanda, F J; Reina, M A; Fornet, I; López, A; López López, M A; Morillas Sendín, P

    2009-01-01

    To determine the incidence of paresthesia during lumbar puncture performed with the patient in different positions. A single-blind prospective study of patients scheduled for elective cesarean section, randomized to 3 groups. In group 1 patients were seated in the direction of the long axis of the table, with heels resting on the table. In group 2 they were seated perpendicular to the long axis of the table, with legs hanging from the table. In group 3 they were in left lateral decubitus position. Lumbar punctures were performed with a 27-gauge Whitacre needle. One hundred sixty-eight patients (56 per group) were enrolled. Paresthesia occurred most often in group 3 (P = .009). We observed no differences in blood pressure after patients moved from decubitus position to the assigned position. Nor did we observe between-group differences in blood pressure according to position taken during puncture. Puncture undertaken with the patient seated, heels on the table and knees slightly bent, is associated with a lower incidence of paresthesia than puncture performed with the patient seated, legs hanging from the table. Placing the patient's heels on the table requires hip flexion and leads to anterior displacement of nerve roots in the dural sac. Such displacement would increase the nerve-free zone on the posterior side of the sac, thereby decreasing the likelihood of paresthesia during lumbar puncture. A left lateral decubitus position would increase the likelihood of paresthesia, possibly because the anesthetist may inadvertently not follow the medial line when inserting the needle.

  17. Accidental dural puncture, postdural puncture headache, intrathecal catheters, and epidural blood patch: revisiting the old nemesis.

    PubMed

    Kaddoum, Roland; Motlani, Faisal; Kaddoum, Romeo N; Srirajakalidindi, Arvi; Gupta, Deepak; Soskin, Vitaly

    2014-08-01

    One of the controversial management options for accidental dural puncture in pregnant patients is the conversion of labor epidural analgesia to continuous spinal analgesia by threading the epidural catheter intrathecally. No clear consensus exists on how to best prevent severe headache from occurring after accidental dural puncture. To investigate whether the intrathecal placement of an epidural catheter following accidental dural puncture impacts the incidence of postdural puncture headache (PDPH) and the subsequent need for an epidural blood patch in parturients. A retrospective chart review of accidental dural puncture was performed at Hutzel Women's Hospital in Detroit, MI, USA for the years 2002-2010. Documented cases of accidental dural punctures (N = 238) were distributed into two groups based on their management: an intrathecal catheter (ITC) group in which the epidural catheter was inserted intrathecally and a non-intrathecal catheter (non-ITC) group that received the epidural catheter inserted at different levels of lumbar interspaces. The incidence of PDPH as well as the necessity for epidural blood patch was analyzed using two-tailed Fisher's exact test. In the non-ITC group, 99 (54 %) parturients developed PDPH in comparison to 20 (37 %) in the ITC [odds ratio (OR), 1.98; 95 % confidence interval (CI), 1.06-3.69; P = 0.03]. Fifty-seven (31 %) of 182 patients in the non-ITC group required an epidural blood patch (EBP) (data for 2 patients of 184 were missing). In contrast, 7 (13 %) of parturients in the ITC group required an EBP. The incidence of EBP was calculated in parturients who actually developed headache to be 57 of 99 (57 %) in the non-ITC group versus 7 of 20 (35 %) in the ITC group (OR, 2.52; 95 % CI, 0.92-6.68; P = 0.07). The insertion of an intrathecal catheter following accidental dural puncture decreases the incidence of PDPH but not the need for epidural blood patch in parturients.

  18. Subdural Hematoma Associated With Labor Epidural Analgesia: A Case Series.

    PubMed

    Lim, Grace; Zorn, Jamie M; Dong, Yuanxu J; DeRenzo, Joseph S; Waters, Jonathan H

    2016-01-01

    This report aimed to describe the characteristics and impact of subdural hematoma (SDH) after labor epidural analgesia. Eleven obstetric patients had SDHs associated with the use of labor epidural analgesia over 7 years at a tertiary care hospital. Ten of 11 patients had signs consistent with postdural puncture headache before the diagnosis of SDH. Five patients (45%) had a recognized unintentional dural puncture, 1 (9%) had a combined spinal-epidural with a 24-gauge needle, and 5 (45%) had no recognized dural puncture. For 10 of the 11 cases, SDH was diagnosed at a mean of 4.1 days (range, 1-7 days) after performance of labor epidural analgesia; one case was diagnosed at 25 days. Ten (91%) of 11 cases had a second hospital stay for a mean of 2.8 days (range, 2-4 days) for observation, without further requirement for neurosurgical intervention. One case (9%) had decompressive hemicraniectomy after becoming unresponsive. The observed rate of labor epidural analgesia-associated SDH was 0.026% (11 in 42,969, approximately 1:3900), and the rate of SDH was 1.1% (5 in 437, approximately 1:87) if a recognized dural puncture occurred during epidural catheter placement. Subdural hematoma after labor epidural anesthesia is rare but potentially more common than historically estimated. Cases of postdural puncture headache after labor epidural anesthesia should be monitored closely for severe neurologic signs and symptoms that could herald SDH.

  19. Simulation and training of lumbar punctures using haptic volume rendering and a 6DOF haptic device

    NASA Astrophysics Data System (ADS)

    Färber, Matthias; Heller, Julika; Handels, Heinz

    2007-03-01

    The lumbar puncture is performed by inserting a needle into the spinal chord of the patient to inject medicaments or to extract liquor. The training of this procedure is usually done on the patient guided by experienced supervisors. A virtual reality lumbar puncture simulator has been developed in order to minimize the training costs and the patient's risk. We use a haptic device with six degrees of freedom (6DOF) to feedback forces that resist needle insertion and rotation. An improved haptic volume rendering approach is used to calculate the forces. This approach makes use of label data of relevant structures like skin, bone, muscles or fat and original CT data that contributes information about image structures that can not be segmented. A real-time 3D visualization with optional stereo view shows the punctured region. 2D visualizations of orthogonal slices enable a detailed impression of the anatomical context. The input data consisting of CT and label data and surface models of relevant structures is defined in an XML file together with haptic rendering and visualization parameters. In a first evaluation the visible human male data has been used to generate a virtual training body. Several users with different medical experience tested the lumbar puncture trainer. The simulator gives a good haptic and visual impression of the needle insertion and the haptic volume rendering technique enables the feeling of unsegmented structures. Especially, the restriction of transversal needle movement together with rotation constraints enabled by the 6DOF device facilitate a realistic puncture simulation.

  20. Effect of venous dexamethasone, oral caffeine and acetaminophen on relative frequency and intensity of postdural puncture headache after spinal anesthesia.

    PubMed

    Masoudifar, Mehrdad; Aghadavoudi, Omid; Adib, Sajjad

    2016-01-01

    Postdural puncture headache (PDPH) is a relatively common complication after regional anesthesia, especially in younger people, bothersome to patients and needs prophylaxis to prevent this complication. This study was conducted aiming to determine the preventive effect of dexamethasone plus caffeine and acetaminophen on relative frequency and intensity of PDPH after spinal anesthesia. In a clinical trial study, 90 candidates for the lower extremities orthopedic elective operation were divided into two groups of 45 individuals each. Intervention group received the compound of 500 mg acetaminophen +65 mg oral caffeine +8 mg venous dexamethasone an hour before spinal blocking, and the control group received placebo tablets + a dexamethasone equivalent volume of venous normal saline. The level of postoperative headache at the time of entrance to recovery and discharge, 6, 12, 24, 48, and 72 h postoperatively were measured based on Visual Analog Scale criterion in the two groups and then compared with each other. During the study, 24 patients in the control group and 17 patients in the intervention group were afflicted with headache; however, with no significant difference (P = 0.14). Total frequency of headache incidence was 35 times in the control group and 27 times in the intervention group (P = 0.32). Though the taking of acetaminophen + caffeine + dexamethasone is associated with a decrease in headache intensity and duration and decrease in PDPH incidence, compared with placebo, however, no essentially and statistically significant effect was produced.

  1. Bacterial contamination of epidural catheters: microbiological examination of 502 epidural catheters used for postoperative analgesia.

    PubMed

    Steffen, Peter; Seeling, Wulf; Essig, Andreas; Stiepan, Erika; Rockemann, Michael Georg

    2004-03-01

    To investigate the frequency of bacterial colonization of epidural catheters used for postoperative pain treatment longer than 24 hours in abdominal, thoracic, or trauma surgery patients. Retrospective study. Intermediate care facility and general ward of a university hospital. 502 patients who received epidural catheters after abdominal, thoracic, or vascular surgery at our institution from January 1996 to December 2000. Placement of an epidural catheter, which was used for postoperative pain treatment, for more than 24 hours. The puncture site dressing included saturation each day with povidone-iodine. Microbiologic monitoring of epidural catheter tips and daily examination of puncture sites with regard to signs of inflammation took place. Four times daily patients were examined to check adequacy of pain treatment and neurologic deficits. Catheter tip cultures were positive in 29 patients (5.8%). Staphylococcus epidermidis was isolated in 22 cases (76%). No case of spinal epidural abscess was observed within 6 months after epidural catheterization. The average catheterization time was 5 days (quartile range: 4 to 6 days). Meticulous management ensures a relatively low level of bacterial contamination in epidural catheters applied for postoperative pain treatment greater than 5 days. Contamination rarely leads to spinal epidural infection.

  2. Laparoscopic Cholecystectomy under Segmental Thoracic Spinal Anesthesia: A Feasible Economical Alternative.

    PubMed

    Kejriwal, Aditya Kumar; Begum, Shaheen; Krishan, Gopal; Agrawal, Richa

    2017-01-01

    Laparoscopic surgery is normally performed under general anesthesia, but regional techniques like thoracic epidural and lumbar spinal have been emerging and found beneficial. We performed a clinical case study of segmental thoracic spinal anaesthesia in a healthy patient. We selected an ASA grade I patient undergoing elective laparoscopic cholecystectomy and gave spinal anesthetic in T10-11 interspace using 1 ml of bupivacaine 5 mg ml -1 mixed with 0.5 ml of fentanyl 50 μg ml -1 . Other drugs were only given (systemically) to manage patient anxiety, pain, nausea, hypotension, or pruritus during or after surgery. The patient was reviewed 2 days postoperatively in ward. The thoracic spinal anesthetia was performed easily in the patient. Some discomfort which was readily treated with 1mg midazolam and 20 mg ketamine intravenously. There was no neurological deficit and hemodynamic parameters were in normal range intra and post-operatively and recovery was uneventful. We used a narrow gauze (26G) spinal needle which minimized the trauma to the patient and the chances of PDPH, which was more if 16 or 18G epidural needle had been used and could have increased further if there have been accidental dura puncture. Also using spinal anesthesia was economical although it should be done cautiously as we are giving spinal anesthesia above the level of termination of spinal cord.

  3. Laparoscopic Cholecystectomy under Segmental Thoracic Spinal Anesthesia: A Feasible Economical Alternative

    PubMed Central

    Kejriwal, Aditya Kumar; Begum, Shaheen; Krishan, Gopal; Agrawal, Richa

    2017-01-01

    Laparoscopic surgery is normally performed under general anesthesia, but regional techniques like thoracic epidural and lumbar spinal have been emerging and found beneficial. We performed a clinical case study of segmental thoracic spinal anaesthesia in a healthy patient. We selected an ASA grade I patient undergoing elective laparoscopic cholecystectomy and gave spinal anesthetic in T10-11 interspace using 1 ml of bupivacaine 5 mg ml−1 mixed with 0.5 ml of fentanyl 50 μg ml−1. Other drugs were only given (systemically) to manage patient anxiety, pain, nausea, hypotension, or pruritus during or after surgery. The patient was reviewed 2 days postoperatively in ward. The thoracic spinal anesthetia was performed easily in the patient. Some discomfort which was readily treated with 1mg midazolam and 20 mg ketamine intravenously. There was no neurological deficit and hemodynamic parameters were in normal range intra and post-operatively and recovery was uneventful. We used a narrow gauze (26G) spinal needle which minimized the trauma to the patient and the chances of PDPH, which was more if 16 or 18G epidural needle had been used and could have increased further if there have been accidental dura puncture. Also using spinal anesthesia was economical although it should be done cautiously as we are giving spinal anesthesia above the level of termination of spinal cord. PMID:28928589

  4. Effect of spinal needle characteristics on measurement of spinal canal opening pressure.

    PubMed

    Bellamkonda, Venkatesh R; Wright, Thomas C; Lohse, Christine M; Keaveny, Virginia R; Funk, Eric C; Olson, Michael D; Laack, Torrey A

    2017-05-01

    A wide variety of spinal needles are used in clinical practice. Little is currently known regarding the impact of needle length, gauge, and tip type on the needle's ability to measure spinal canal opening pressure. This study aimed to investigate the relationship between these factors and the opening-pressure measurement or time to obtain an opening pressure. Thirteen distinct spinal needles, chosen to isolate the effects of length, gauge, and needle-point type, were prospectively tested on a lumbar puncture simulator. The key outcomes were the opening-pressure measurement and the time required to obtain that measure. Pressures were recorded at 10-s intervals until 3 consecutive, identical readings were observed. Time to measure opening pressure increased with increasing spinal needle length, increasing gauge, and the Quincke-type (cutting) point (P<0.001 for all). The time to measurement ranged from 30s to 530s, yet all needle types were able to obtain a consistent opening pressure measure. Although opening pressure estimates are unlikely to vary markedly by needle type, the time required to obtain the measurement increased with increasing needle length and gauge and with Quincke-type needles. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Real-Time Ultrasound-Guided Spinal Anaesthesia: A Prospective Observational Study of a New Approach

    PubMed Central

    Conroy, P. H.; Luyet, C.; McCartney, C. J.; McHardy, P. G.

    2013-01-01

    Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice. PMID:23365568

  6. [Postspinal headache. A comparison of the 24G Sprotte syringe and a 29G Quincke needle].

    PubMed

    Lim, M; Cross, G D; Sold, M

    1992-09-01

    A randomised study was performed to compare the frequency of postdural puncture headache in 56 patients who underwent spinal anaesthesia for extra-corporeal shockwave lithotripsy using either a Sprotte 24 G (n = 28) or Vygon 29 G or Quincke type needle (n = 28). Frequency of headache was recorded in a similar group of 28 patients who received general anaesthesia. Dural puncture was easier with the Sprotte 24 G cannula than with the less stable Quincke needle, as documented by a significantly shortened time for insertion of the cannula (4.6 +/- 2.6 vs 8.6 +/- 6.3 min, P less than 0.005). The total frequency of post-operative headache was 57% in the Vygon 29 G group and 25% in the Sprotte 24 G group; 21% of patients in the general anaesthesia group complained of headache. Frequency of postdural puncture headache, classified as being posture-related, was 25% in the 29 G Vygon group, compared with 11% in the 24 G Sprotte group (P = 0.148). When only moderate and severe postdural puncture headache was considered, there was a significant difference (25% vs. 4%; P = 0.026) in favour of the Sprotte cannula. Thus, the 24 G Sprotte needle was at least as effective as the 29 G Vygon needle, and there is a suggestion that the former is more effective in minimising the incidence of moderate or severe postdural puncture headache.

  7. Comparison of sprotte and Quincke needles with respect to spinal fluid leakage using artificial spinal cord.

    PubMed

    Amaki, Yoshikiyo; Moriyama, Michihiko; Kuzuta, Toshimichi; Yabe, Keiko; Kaneko, Misato

    1997-12-01

    This research investigated whether the Sprotte needle causes less leakage of CSF than the Quincke needle in the artificial spinal cord. The changes in intradural pressure, extradural pressure, and leaked volume of CSF were evaluated following puncture with Sprotte and Quincke needles in the artificial spinal cord. The decrease in intradural pressure was 9.7±1.8 mm H 2 O with the Sprotte needle and 20.5±2.7 mm H 2 O with the Quincke needle (P<0.05). The volume of leakage of artificial CSF was 2.0±0.3 ml with the Sprotte needle and 3.3 ±0.3 ml with the Quincke needle (P<0.01). The extradural pressure increase was 166.1±8.2 mm H 2 O with the Sprotte needle and 186.8±13.2 mm H 2 O with the Quincke needle (P<0.05). The Sprotte needle produces less CSF leakage than the Quincke needle.

  8. Ultrasound-guided bilateral greater occipital nerve block for the treatment of post-dural puncture headache

    PubMed Central

    Akyol, Fethi; Binici, Orhan; Kuyrukluyildiz, Ufuk; Karabakan, Guldane

    2015-01-01

    Background and Objective: Post-dural puncture headache (PDPH) is one of the complications frequently observed after spinal or epidural anesthesia with dural penetration. For PDPH patients who do not respond to conservative medical treatment, alternative treatments such as bilateral occipital nerve block should be considered.In this study the efficacy of bilateral occipital nerve block was retrospectively evaluated in patients with post-dural puncture headache. Methods: Ultrasound-guided bilateral occipital nerve block was administrated in 21 patients who developed PDPH after spinal anesthesia, but did not respond to conservative medical treatment within 48 hours between January 2012 and February 2014. The study was conducted at Erzincan University Faculty of Medicine Gazi Mengucek Education and Research Hospital Results: Mean Visual Analog Scale (VAS) pain scores at 10 minutes and 6, 10, 15 and 24 hours after the block were significantly improved compared to the patients with a pre-block VAS score between 4 and 6 as well as patients with a pre-block VAS score between 7 and 9 (p<0.01). After 24 hours of the block applied, VAS pain score dropped to 1 for all 12 patients who had a pre-block VAS score between 4 and 6. Whereas, VAS score decreased to 2 at 24 hours after the block in only one of the patients with a pre-block VAS between 7 and 9. For the patients with a pre-block VAS score between 7 and 9, there was no significant improvement in the mean VAS score 24 hours after the block. Conclusions: For patients with PDPH and a pre-block VAS score between 4 and 6 who do not respond to conservative medical treatment, an ultrasound-guided bilateral occipital nerve block may be effective. PMID:25878625

  9. Molecular mechanisms underlying the effects of acupuncture on neuropathic pain

    PubMed Central

    Ju, Ziyong; Cui, Huashun; Guo, Xiaohui; Yang, Huayuan; He, Jinsen; Wang, Ke

    2013-01-01

    Acupuncture has been used to treat neuropathic pain for a long time, but its mechanisms of action remain unknown. In this study, we observed the effects of electroacupuncture and manual acu-puncture on neuropathic pain and on ephrin-B/EphB signaling in rats models of chronic constriction injury-induced neuropathic pain. The results showed that manual acupuncture and elec-puncture significantly reduced mechanical hypersensitivity following chronic constriction injury, es-pecially electroacupuncture treatment. Real-time PCR results revealed that ephrin-B1/B3 and EphB1/B2 mRNA expression levels were significantly increased in the spinal dorsal horns of chronic constriction injury rats. Electroacupuncture and manual acupuncture suppressed the high sion of ephrin-B1 mRNA, and elevated EphB3/B4 mRNA expression. Electroacupuncture signifi-cantly enhanced the mRNA expression of ephrin-B3 and EphB3/B6 in the dorsal horns of neuro-pathic pain rats. Western blot results revealed that electroacupuncture in particular, and manual acupuncture, significantly up-regulated ephrin-B3 protein levels in rat spinal dorsal horns. The re-sults of this study suggest that acupuncture could activate ephrin-B/EphB signaling in neuropathic pain rats and improve neurological function. PMID:25206545

  10. Molecular mechanisms underlying the effects of acupuncture on neuropathic pain.

    PubMed

    Ju, Ziyong; Cui, Huashun; Guo, Xiaohui; Yang, Huayuan; He, Jinsen; Wang, Ke

    2013-09-05

    Acupuncture has been used to treat neuropathic pain for a long time, but its mechanisms of action remain unknown. In this study, we observed the effects of electroacupuncture and manual acu-puncture on neuropathic pain and on ephrin-B/EphB signaling in rats models of chronic constriction injury-induced neuropathic pain. The results showed that manual acupuncture and elec-puncture significantly reduced mechanical hypersensitivity following chronic constriction injury, es-pecially electroacupuncture treatment. Real-time PCR results revealed that ephrin-B1/B3 and EphB1/B2 mRNA expression levels were significantly increased in the spinal dorsal horns of chronic constriction injury rats. Electroacupuncture and manual acupuncture suppressed the high sion of ephrin-B1 mRNA, and elevated EphB3/B4 mRNA expression. Electroacupuncture signifi-cantly enhanced the mRNA expression of ephrin-B3 and EphB3/B6 in the dorsal horns of neuro-pathic pain rats. Western blot results revealed that electroacupuncture in particular, and manual acupuncture, significantly up-regulated ephrin-B3 protein levels in rat spinal dorsal horns. The re-sults of this study suggest that acupuncture could activate ephrin-B/EphB signaling in neuropathic pain rats and improve neurological function.

  11. Spinal analgesia and auditory functions: a comparison of two sizes of Quincke needle.

    PubMed

    Malhotra, S K; Iyer, B A; Gupta, A K; Raghunathan, M; Nakra, D

    2007-01-01

    Spinal anaesthesia may produce complications ranging from minor problems such as pain on injection, backache and urinary retention to more serious consequences such as post-dural puncture headache (PDPH), neurological complications like meningitis, cranial and peripheral nerve palsies and even cardiac arrest. Impaired auditory function is a relatively lesser-recognized complication of spinal analgesia. The objective of this study was to investigate the effects of spinal analgesia on vestibular dysfunction, using different sizes of the same type of spinal needle. The study included 30 ASA I patients who had received spinal analgesia for lower abdominal surgery. Pure tone audiometry was performed before surgery and on postoperative day 2. In addition, any patient with hearing impairment of >15 dB was scheduled to undergo electrocochleography. Hearing levels were measured from 250 Hz to 8 kHz. In group 1 (n=15), a 26gauge Quincke needle was used. In group 2 (n=15), a 23-gauge Quincke needle was used. Comparison of hearing thresholds showed a significant reduction in the hearing level (P<0.05) in 2 patients in group 2 but none in group 1. The use of a 23-gauge Quincke needle is associated with a greater reduction in the mean hearing level compared to a 26-gauge needle of the same type.

  12. Predictors of failure of awake regional anesthesia for neonatal hernia repair: data from the General Anesthesia compared to Spinal anesthesia (GAS) study: comparing apnoea and neurodevelopmental outcomes

    PubMed Central

    Frawley, Geoff; Bell, Graham; Disma, Nicola; Withington, Davinia E.; de Graaff, Jurgen C.; Morton, Neil S.; McCann, Mary Ellen; Arnup, Sarah J.; Bagshaw, Oliver; Wolfler, Andrea; Bellinger, David; Davidson, Andrew J.

    2015-01-01

    Background Awake regional anesthesia (RA) is a viable alternative to general anesthesia (GA) for infants undergoing lower abdominal surgery. Benefits include lower incidence of postoperative apnea and avoidance of anesthetic agents that may increase neuroapoptosis and worsen neurocognitive outcomes. The General Anesthesia compared to Spinal anesthesia (GAS) study compares neurodevelopmental outcomes following awake RA or GA in otherwise healthy infants. Our aim was to describe success and failure rates of RA in this study and report factors associated with failure. Methods This was a nested cohort study within a prospective randomized, controlled, observer blind, equivalence trial. Seven hundred twenty two infants ≤ 60 weeks postmenstrual age, scheduled for herniorrhaphy under anesthesia were randomly assigned to receive RA (spinal, caudal epidural or combined spinal caudal anesthetic) or GA with sevoflurane. The data of 339 infants, where spinal or combined spinal caudal anesthetic was attempted, was analyzed. Possible predictors of failure were assessed including: patient factors, technique, experience of site and anesthetist and type of local anesthetic. Results RA was sufficient for the completion of surgery in 83.2% of patients. Spinal anesthesia was successful in 86.9% of cases and combined spinal caudal anesthetic in 76.1%. Thirty four patients required conversion to GA and an additional 23 (6.8%) required brief sedation. Bloody tap on the first attempt at lumbar puncture was the only risk factor significantly associated with block failure (OR = 2.46). Conclusions The failure rate of spinal anesthesia was low. Variability in application of combined spinal caudal anesthetic limited attempts to compare the success of this technique to spinal alone. PMID:26001028

  13. Acute deterioration in occult Chiari malformation following missile spinal trauma. Case report.

    PubMed

    Shahlaie, Kiarash; Hartman, Jonathan; Utter, Garth H; Schrot, Rudolph J

    2008-04-01

    Patients with Chiari malformation (CM) Type I typically experience chronic, slowly progressive symptoms. Rarely, however, do they suffer acute neurological deterioration following an iatrogenic decrease in caudal cerebrospinal fluid pressure due to, for example, a lumbar puncture. To our knowledge, acute neurological deterioration following missile spinal injury in CM has not been previously described. The authors report on a 16-year-old girl who was shot in the abdomen and lumbar spine. Although neurologically intact on initial workup, she developed precipitous quadriplegia and apnea in a delayed fashion. Tonsillar herniation with medullary compression and cerebellar infarction was diagnosed on magnetic resonance imaging. Suboccipital decompression resulted in significant neurological improvement. Well-formed tonsillar ectopia diagnosed at surgery suggested a preexisting CM. The authors conclude that missile spinal trauma can precipitate medullary compression and acute neurological decline, especially in patients with preexisting tonsillar ectopia. Immediate operative decompression to relieve impaction at the cervicomedullary junction can result in significant neurological recovery.

  14. Subdural Hematoma Associated With Labor Epidural Analgesia: A Case Series

    PubMed Central

    Lim, Grace; Zorn, Jamie M.; Dong, Yuanxu J.; DeRenzo, Joseph S.; Waters, Jonathan H.

    2016-01-01

    Objective This report describes the characteristics and impact of subdural hematoma (SDH) after labor epidural analgesia. Case Reports Eleven obstetric patients had subdural hematomas (SDH) associated with the use of labor epidural analgesia over 7 years at a tertiary care hospital. Ten of 11 patients had signs consistent with post-dural puncture headache (PDPH) prior to the diagnosis of SDH. Five patients (45%) had a recognized unintentional dural puncture, 1 (9%) had a combined spinal-epidural with a 24-gauge needle, and 5 (45%) had no recognized dural puncture. For 10 of the 11 cases, SDH was diagnosed an average of 4.1 (range 1–7) days after performance of labor epidural analgesia; one case was diagnosed at 25 days. Ten of 11 (91%) cases had a second hospital stay for an average of 2.8 (range 2–4) days for observation, without further requirement for neurosurgical intervention. One case (9%) had decompressive hemicraniectomy after becoming unresponsive. The observed rate of labor epidural analgesia-associated SDH was 0.026% (11 in 42,969, about 1:3900), and the rate of SDH was 1.1% (5 in 437, about 1:87) if a recognized dural puncture occurred during epidural catheter placement. Conclusions SDH after labor epidural anesthesia is rare, but potentially more common than historically estimated. Cases of PDPH after labor epidural anesthesia should be monitored closely for severe neurologic signs and symptoms that could herald SDH. PMID:27512937

  15. Serratia marcescens meningitis following spinal anaesthesia and arthroscopy.

    PubMed

    Hadzic, Amir; Koluder-Cimic, Nada; Hadzovic-Cengic, Meliha; Gojak, Refet; Gavrankapetanovic, Ismet; Becirbegovic, Semin

    2012-01-01

    We present case of nosocomial bacterial meningitis, caused by Serratia marcescens (ESBL), occurred following spinal anaesthesia. Although very rare bacterial meningitis is serious complication of spinal anaesthesia and early diagnosis as well as effective treatment is extremely important. Previously healthy individual, admitted to Orthopaedic Department for routine arthroscopy, approximately within 24 hours after operation was performed complained of headache and fever. Infectious Diseases physician was consulted, lumbar puncture was performed and purulent meningitis was confirmed. Cerebrospinal fluid and blood cultures of patient confirmed Serratia marcescens (ESBL), resistant pathogen and important nosocomial agent. Patient was successfully treated. Cases of spinal meningitis caused by Serratia marcescens are rare. Local resistance pattern is important and should be always considered when starting therapy. Infection control team was appointed because of similar case of meningitis one month before in the same Department, and after investigation discovered Serratia in anaesthetic vial used in procedures. New measures and recommendations regarding infection control were implemented at Orthopaedic Department. Meningitis as a complication should always be considered as a possible differential diagnosis with patients after spinal anaesthesia complaining on headache and fever. Early diagnosis and early treatment is extremely important. Knowledge and practice of infection control measures is mandatory and should be always emphasized to performing staff.

  16. Spinal Subdural Abscess Following Laminectomy for Symptomatic Stenosis: A Report of 2 Cases and Review of the Literature.

    PubMed

    Ramos, Alexander D; Rolston, John D; Gauger, Grant E; Larson, Paul S

    2016-07-12

    BACKGROUND Spinal subdural abscesses, also known as empyemas, are rare infectious lesions, the exact incidence of which is unknown. Presentation is typically dramatic, with back pain, fever, motor, and sensory deficits. Rapid identification and surgical intervention with laminectomy, durotomy, and washout provides the best outcomes. While hematogenous spread of an extra-spinal infection is the most common cause of this condition, a significant number of cases result from iatrogenic mechanisms, including lumbar punctures, epidural injections, and surgery. CASE REPORT Here we present 2 cases: 1) an 87-year-old man with type 2 diabetes, schizophrenia, mild cognitive impairment, and symptomatic lumbar spinal stenosis and 2) a 62-year-old man with a prior L3-4 spinal fusion with symptomatic lumbar spinal stenosis. In both cases, patients underwent laminectomy for spinal stenosis and developed epidural abscess. Following successful drainage of the epidural abscess, they continued to be symptomatic, and repeat imaging revealed the presence of a subdural abscess that was subsequently evacuated. Case 1 had significant improvement with residual lower-extremity weakness, while Case 2 made a complete neurological recovery. CONCLUSIONS These cases illustrate patients at increased risk for developing this rare spinal infection, and demonstrate that rapid recognition and surgical treatment is key to cure and recovery. Review of the literature highlights pertinent risk factors and demonstrates nearly one-third of reported cases have an iatrogenic etiology. The cases presented here demonstrate that a subdural process should be suspected in any patient with intractable pain following treatment of an epidural abscess.

  17. [The effect of needle type and immobilization on postspinal headache].

    PubMed

    Hafer, J; Rupp, D; Wollbrück, M; Engel, J; Hempelmann, G

    1997-10-01

    Post-dural puncture headache (PDPH) is a significant complication of spinal anaesthesia. Diameter and tip of the needle as well as the patient's age have been proven to be important determinants. The question of whether post-operative recumbency can reduce the risk of PDPH has not been answered uniformly. And besides, some studies referring to this subject reveal methodical failures, for example, as to clear definition and exact documentation of post-operative immobilization. Furthermore, fine-gauge needles (26G or more) have not been investigated yet. The first aim of our study was therefore to examine the role of recumbency in the prevention of PDPH under controlled conditions using thin needles. Secondly, we wanted to confirm the reported prophylactic effect of needles with a modified, atraumatic tip (Whitacre and Atraucan) by comparing them to Quincke needles of identical diameter. Most of the former investigators compared Quincke with atraumatic needles of different size regardless of the known influence of the diameter on PDPH. In a prospective study we included 481 consecutive patients undergoing a total of 500 orthopaedic operations under spinal anaesthesia. The latter was performed in a standardized manner (patient sitting, midline approach, needle with parallel bevel direction), using four different needles allocated randomly (26-gauge and 27-gauge needles with Quincke tip, 26-gauge Atraucan and 27-gauge Whitacre cannula). Half of the patients were instructed to stay in bed for 24 h (horizontal position without raising head), the others to get up as early as possible. An anaesthesiologist visited the patients on the fourth postoperative day or later and questioned them about headache and duration of recumbency. Additionally, the patients had to fill out a questionnaire 1 week after surgery. Any postural headache was considered as PDPH. The four groups of different needles had homogeneous demographic characteristics (see Table 1). A total of 47 patients (9.4%) developed PDPH. The incidence was highest after puncture with a 26-gauge Quincke cannula (17.6%) with a significant difference compared to the other needles (see Table 2). PDPH incidence correlated well with increasing age and number of dural punctures, but showed no relation to sex, patient's history of headache or experience of the anaesthesiologist. Only about half of the patients (60.5%) followed the instructions regarding mobilization or recumbency. The duration of strict bed rest did not influence the development of PDPH: The overall incidence was 9.4% in the recumbency group and 8.8% in the group of early ambulation. In all, 45 patients suffered from ordinary not posture-related headache. The significantly higher incidence of PDPH after spinal anaesthesia with 26-gauge Quincke needles compared to the 27-gauge Quincke and the 26-gauge Atraucan group confirmed the importance of both needle diameter and design of its tip. The Atraucan cannula has not been examined in a controlled study (in comparison with Quincke needle of the same diameter) before. In accordance with other investigators we found patient's age and number of puncture attempts as additional predictors of PDPH. Consequent bed rest, however, was not able to reduce its incidence. Our studies reveal the poor compliance of patients with regard to mobilization/immobilization, a problem which possibly has not been considered enough in former studies examining the influence of bed rest on PDPH. Based on the literature and the present findings, we recommend using thin needles with atraumatic tips for spinal anaesthesia if possible. Recumbency presents an avoidable stress for patients as well as medical staff and should no longer be ordered.

  18. Dose-response study of spinal hyperbaric ropivacaine for cesarean section

    PubMed Central

    Chen, Xin-zhong; Chen, Hong; Lou, Ai-fei; Lü, Chang-cheng

    2006-01-01

    Background: Spinal hyperbaric ropivacaine may produce more predictable and reliable anesthesia than plain ropivacaine for cesarean section. The dose-response relation for spinal hyperbaric ropivacaine is undetermined. This double-blind, randomized, dose-response study determined the ED50 (50% effective dose) and ED95 (95% effective dose) of spinal hyperbaric ropivacaine for cesarean section anesthesia. Methods: Sixty parturients undergoing elective cesarean section delivery with use of combined spinal-epidural anesthesia were enrolled in this study. An epidural catheter was placed at the L1~L2 vertebral interspace, then lumbar puncture was performed at the L3~L4 vertebral interspace, and parturients were randomized to receive spinal hyperbaric ropivacaine in doses of 10.5 mg, 12 mg, 13.5 mg, or 15 mg in equal volumes of 3 ml. Sensory levels (pinprick) were assessed every 2.5 min until a T7 level was achieved and motor changes were assessed by modified Bromage Score. A dose was considered effective if an upper sensory level to pin prick of T7 or above was achieved and no intraoperative epidural supplement was required. ED50 and ED95 were determined with use of a logistic regression model. Results: ED50 (95% confidence interval) of spinal hyperbaric ropivacaine was determined to be 10.37 (5.23~11.59) mg and ED95 (95% confidence interval) to be 15.39 (13.81~23.59) mg. The maximum sensory block levels and the duration of motor block and the rate of hypotension, but not onset of anesthesia, were significantly related to the ropivacaine dose. Conclusion: The ED50 and ED95 of spinal hyperbaric ropivacaine for cesarean delivery under the conditions of this study were 10.37 mg and 15.39 mg, respectively. Ropivacaine is suitable for spinal anesthesia in cesarean delivery. PMID:17111469

  19. Hydrogel-based scaffolds to support intrathecal stem cell transplantation as a gateway to the spinal cord: clinical needs, biomaterials, and imaging technologies.

    PubMed

    Oliveira, J Miguel; Carvalho, Luisa; Silva-Correia, Joana; Vieira, Sílvia; Majchrzak, Malgorzata; Lukomska, Barbara; Stanaszek, Luiza; Strymecka, Paulina; Malysz-Cymborska, Izabela; Golubczyk, Dominika; Kalkowski, Lukasz; Reis, Rui L; Janowski, Miroslaw; Walczak, Piotr

    2018-01-01

    The prospects for cell replacement in spinal cord diseases are impeded by inefficient stem cell delivery. The deep location of the spinal cord and complex surgical access, as well as densely packed vital structures, question the feasibility of the widespread use of multiple spinal cord punctures to inject stem cells. Disorders characterized by disseminated pathology are particularly appealing for the distribution of cells globally throughout the spinal cord in a minimally invasive fashion. The intrathecal space, with access to a relatively large surface area along the spinal cord, is an attractive route for global stem cell delivery, and, indeed, is highly promising, but the success of this approach relies on the ability of cells (1) to survive in the cerebrospinal fluid (CSF), (2) to adhere to the spinal cord surface, and (3) to migrate, ultimately, into the parenchyma. Intrathecal infusion of cell suspension, however, has been insufficient and we postulate that embedding transplanted cells within hydrogel scaffolds will facilitate reaching these goals. In this review, we focus on practical considerations that render the intrathecal approach clinically viable, and then discuss the characteristics of various biomaterials that are suitable to serve as scaffolds. We also propose strategies to modulate the local microenvironment with nanoparticle carriers to improve the functionality of cellular grafts. Finally, we provide an overview of imaging modalities for in vivo monitoring and characterization of biomaterials and stem cells. This comprehensive review should serve as a guide for those planning preclinical and clinical studies on intrathecal stem cell transplantation.

  20. [The relationship between preoperative anxiety levels and vasovagal incidents during the administration of spinal anesthesia].

    PubMed

    Ekinci, Mürsel; Gölboyu, Birzat Emre; Dülgeroğlu, Onur; Aksun, Murat; Baysal, Pınar Karaca; Çelik, Erkan Cem; Yeksan, Ayşe Nur

    It was aimed to investigate the relationship between preoperative anxiety and vasovagal symptoms observed during the administration of spinal anesthesia in patients undergoing surgery in the perianal and inguinal regions. The study included patients with planned surgery for inguinal hernia repair, anal fissure, hemorrhoid and pilonidal sinus excision. The study included a total of 210 patients of ASA I-II, aged 18-65 years. Patients were evaluated in respect of demographic characteristics, smoking and alcohol consumption, ASA grade and educational level. Correlations were evaluated between the number of attempts at spinal anesthesia and anesthesia history with vasovagal symptoms and educational level, gender, smoking and alcohol consumption and anesthesia history with anxiety scores. The instant (transient) state anxiety inventory part of the Transient State/Trait Anxiety Inventory (State Trait Anxiety Inventory - STAI) was used to determine the anxiety levels of the participants. Clinical findings of peripheral vasodilation, hypotension, bradycardia and asystole observed during the administration of spinal anesthesia were recorded. Vasovagal incidences during the administration of spinal anesthesia were seen to increase in cases of high anxiety score, male gender, and an absence of anesthesia history. Educational level and the number of spinal needle punctures were not found to have any effect on vasovagal incidents. The determination of causes triggering vasovagal incidents seen during the application of spinal anesthesia, better patient information of regional anesthesia implementations and anxiety relief with preoperative anxiolytic treatment will help to eliminate potential vasovagal incidents. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  1. The effects of needle deformation during lumbar puncture.

    PubMed

    Özdemir, Hasan Hüseyin; Demir, Caner F; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH.

  2. Spinal anesthesia for inguinal hernia repair in infants: a feasible and safe method even in emergency cases.

    PubMed

    Lambertz, A; Schälte, G; Winter, J; Röth, A; Busch, D; Ulmer, T F; Steinau, G; Neumann, U P; Klink, C D

    2014-10-01

    Inguinal hernia repair is the most frequently performed surgical procedure in infants and children. Especially in premature infants, prevalence reaches up to 30% in coincidence with high rates of incarceration during the first year of life. These infants carry an increased risk of complications due to general anesthesia. Thus, spinal anesthesia is a topic of growing interest for this group of patients. We hypothesized that spinal anesthesia is a feasible and safe option for inguinal hernia repair in infants even at high risk and cases of incarceration. Between 2003 and 2013, we operated 100 infants younger than 6 months with inguinal hernia. Clinical data were collected prospectively and retrospectively analyzed. Patients were divided into two groups depending on anesthesia procedure (spinal anesthesia, Group 1 vs. general anesthesia, Group 2). Spinal anesthesia was performed in 69 infants, and 31 infants were operated in general anesthesia, respectively. In 7 of these 31 infants, general anesthesia was chosen because of lumbar puncture failure. Infants operated in spinal anesthesia were significantly smaller (54 ± 4 vs. 57 ± 4 cm; p = 0.001), had a lower body weight (4,047 ± 1,002 vs. 5,327 ± 1,376 g; p < 0.001) and higher rate of prematurity (26 vs. 4%; p = 0.017) compared to those operated in general anesthesia. No complications related to surgery or to anesthesia were found in both groups. The number of relevant preexisting diseases was higher in Group 1 (11 vs. 3%; p = 0.54). Seven of eight emergent incarcerated hernia repairs were performed in spinal anesthesia (p = 0.429). Spinal anesthesia is a feasible and safe option for inguinal hernia repair in infants, especially in high-risk premature infants and in cases of hernia incarceration.

  3. Spinal Anesthesia with Isobaric Tetracaine in Patients with Previous Lumbar Spinal Surgery

    PubMed Central

    Kim, Soo Hwan; Jeon, Dong-Hyuk; Chang, Chul Ho; Lee, Sung-Jin

    2009-01-01

    Purpose Previous lumbar spinal surgery (PLSS) is not currently considered as a contraindication for regional anesthesia. However, there are still problems that make spinal anesthesia more difficult with a possibility of worsening the patient's back pain. Spinal anesthesia using combined spinal-epidural anesthesia (CSEA) in elderly patients with or without PLSS was investigated and the anesthetic characteristics, success rates, and possible complications were evaluated. Materials and Methods Fifty patients without PLSS (Control group) and 45 patients with PLSS (PLSS group) who were scheduled for total knee arthroplasty were studied prospectively. A CSEA was performed with patients in the left lateral position, and 10 mg of 0.5% isobaric tetracaine was injected through a 27 G spinal needle. An epidural catheter was then inserted for patient controlled analgesia. Successful spinal anesthesia was defined as adequate sensory block level more than T12. The number of skin punctures and the onset time were recorded, and maximal sensory block level (MSBL), time to 2-segment regression, success rate and complications were observed. Results The success rate of CSEA in Control group and PLSS group was 98.0%, and 93.3%, respectively. The median MSBL in PLSS group was higher than Control group [T4 (T2-L1) vs. T6 (T3-T12)] (p < 0.001). There was a significant difference in the number of patients who required ephedrine for the treatment of hypotension in PLSS group (p = 0.028). Conclusion The success rate of CSEA in patients with PLSS was 93.3%, and patients experienced no significant neurological complications. The MSBL can be higher in PLSS group than Control group. PMID:19430559

  4. Headache after spinal anesthesia for cesarean section: a comparison of the 27-gauge Quincke and 24-gauge Sprotte needles.

    PubMed

    Mayer, D C; Quance, D; Weeks, S K

    1992-09-01

    A high incidence of postdural puncture headache (PDPH) occurs after spinal anesthesia for cesarean section. To examine this problem, a study was conducted with the recently developed 24-gauge Sprotte and 27-gauge Quincke needles in patients undergoing elective and emergency cesarean section (n = 298). The needle to be used was assigned in a random manner: group I, 27-gauge Quincke (n = 147); group II, 24-gauge Sprotte (n = 151). During the postoperative period, patients were visited daily and asked specifically about the presence and severity of headache. The overall incidence of PDPH was 2% (n = 6), five in the Quincke group (3.5%) and one in the Sprotte group (0.7%). There was no significant difference in the incidence of PDPH between the two groups. Five headaches were classified as mild, and only one was moderate to severe. All headaches resolved quickly with conservative management and without blood patch. The authors conclude that the choice between a 27-gauge Quincke and a 24-gauge Sprotte needle does not influence the incidence of PDPH after spinal anesthesia for cesarean section.

  5. Vestibular and Oculomotor Physiology: International Meeting of the Barany Society. Volume 374. Annals of the New York Academy of Sciences

    DTIC Science & Technology

    1981-11-06

    A. L. 1968. The Brain Stem of the Cat. University of Wisconsin Press. Madison . Wis. 8. KICVER, 1-. & E. BARRERA. 1953. A method for the combined...Inhibition of central vestibular neurons from the W~ UW % labyrinth and its mediating pathway. 1. NeurophysioL 29: 467-492. S1 MI 1111 t BAME & A. GLWTYN. 1980...revealed lethargy, slow speech, nystagmus, dysmetria, and ataxia. A lumbar puncture at that time showed a spinal fluid protein of 110 mg%, glucose of 15

  6. Direct intrathecal drug delivery in mice for detecting in vivo effects of cGMP on pain processing.

    PubMed

    Lu, Ruirui; Schmidtko, Achim

    2013-01-01

    Intrathecal delivery of drugs is an important method in pain research in order to investigate pain-relevant effects in the spinal cord in vivo. Here, we describe a method of intrathecal drug delivery by direct lumbar puncture in mice. The procedure does not require surgery, is rapidly performed, and does not produce neurological deficits. If cGMP analogs are injected, a state of transient hindpaw hypersensitivity can be induced which is quantifiable by measurement of hindpaw withdrawal latency in response to mechanical stimulation.

  7. Conventional Landmark-Guided Midline Versus Preprocedure Ultrasound-Guided Paramedian Techniques in Spinal Anesthesia.

    PubMed

    Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2015-10-01

    Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain during needle insertion, were similar between the 2 groups. Routine use of paramedian spinal anesthesia in the orthopedic patient population undergoing joint replacement surgery, guided by preprocedure ultrasound examination, significantly decreases the number of passes and attempts needed to enter the subarachnoid space.

  8. An unusual presentation of carcinomatous meningitis

    PubMed Central

    Foo, Chuan T.; Burrell, Louise M.; Johnson, Douglas F.

    2016-01-01

    A 67-year old previously well male presented with a 1 week history of confusion on a background of 3 weeks of headache. Past history included two superficial melanomas excised 5 years ago. Treatment for meningoencephalitis was commenced based on lumbar puncture (LP) and non-contrast brain magnetic resonance imaging (MRI) results. Lack of a clinical response to antibiotics resulted in a second LP and contrast brain MRI which demonstrated hydrocephalus and leptomeningeal disease. Ongoing deterioration led to a whole-body computed tomographic and spinal MRI that showed widespread metastatic disease and extensive leptomeningeal involvement of the spinal cord. The diagnosis of metastatic melanoma with carcinomatous meningitis was made based on cytological analysis of cerebrospinal fluid. He died 2 weeks later in a palliative care facility. This case illustrates that the diagnosis of carcinomatous meningitis can be difficult to make as the heterogeneous nature of its presentation often delays the diagnosis. PMID:27574561

  9. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  10. The effects of needle deformation during lumbar puncture

    PubMed Central

    Özdemir, Hasan Hüseyin; Demir, Caner F.; Varol, Sefer; Arslan, Demet; Yıldız, Mustafa; Akil, Eşref

    2015-01-01

    Objective: The aim of this study is to assess deformation of the tip and deflection from the axis of 22-gauge Quincke needles when they are used for diagnostic lumbar puncture (LP). Thus, it can be determined whether constructional alterations of needles are important for predicting clinical problems after diagnostic LP. Materials and Methods: The 22-gauge Quincke needles used for diagnostic LP were evaluated. A specially designed protractor was used for measurement and evaluation. Waist circumference was measured in each patient. Patients were questioned about headaches occurring after LP. Results: A total of 115 Quincke-type spinal needles used in 113 patients were evaluated. No deflection was detected in 38 (33.1%) of the needles. Deflection between 0.1° and 5° occurred in 43 (37.3%) of the needles and deflection ≥ 5.1° occurred in 34 patients (29.6%). Forty-seven (41.5%) patients experienced post lumbar puncture headache (PLPH) and 13 (11.5%) patients experienced intracranial hypotension (IH). No statistically significant correlation between the degree of deflection and headache was found (P > 0.05). Epidural blood patch was performed for three patients. Deformity in the form of bending like a hook occurred in seven needles and IH occurred in six patients using these needles. Two of the needles used in three patients requiring blood patch were found to be bent. Conclusion: Deformation of needles may increase complications after LP. Needle deformation may lead to IH. In case of deterioration in the structure of the needle, termination of the puncture procedure and the use of a new needle could reduce undesirable clinical consequences, especially IH. PMID:25883480

  11. Virtual Simulation in Enhancing Procedural Training for Fluoroscopy-guided Lumbar Puncture: A Pilot Study.

    PubMed

    Ali, Saad; Qandeel, Monther; Ramakrishna, Rishi; Yang, Carina W

    2018-02-01

    Fluoroscopy-guided lumbar puncture (FGLP) is a basic procedural component of radiology residency and neuroradiology fellowship training. Performance of the procedure with limited experience is associated with increased patient discomfort as well as increased radiation dose, puncture attempts, and complication rate. Simulation in health care is a developing field that has potential for enhancing procedural training. We demonstrate the design and utility of a virtual reality simulator for performing FGLP. An FGLP module was developed on an ImmersiveTouch platform, which digitally reproduces the procedural environment with a hologram-like projection. From computed tomography datasets of healthy adult spines, we constructed a 3-D model of the lumbar spine and overlying soft tissues. We assigned different physical characteristics to each tissue type, which the user can experience through haptic feedback while advancing a virtual spinal needle. Virtual fluoroscopy as well as 3-D images can be obtained for procedural planning and guidance. The number of puncture attempts, the distance to the target, the number of fluoroscopic shots, and the approximate radiation dose can be calculated. Preliminary data from users who participated in the simulation were obtained in a postsimulation survey. All users found the simulation to be a realistic replication of the anatomy and procedure and would recommend to a colleague. On a scale of 1-5 (lowest to highest) rating the virtual simulator training overall, the mean score was 4.3 (range 3-5). We describe the design of a virtual reality simulator for performing FGLP and present the initial experience with this new technique. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. [Group B streptococcus meningitis and infection surrounding the spinal canal caused by bacterial transmission from rectal ulcer via Batson's plexus].

    PubMed

    Tsutsumi, Ryosuke; Saito, Masaaki; Yoshizawa, Toshihiro

    2011-07-01

    A 62-year-old man was admitted to our hospital because of fever and disturbed consciousness. He suffered from persistent constipation due to diabetic autonomic neuropathy. On admission, neck stiffness and weakness of the lower extremities were observed. Cerebrospinal fluid (CSF) pleocytosis and decreased CSF glucose concentration showed the presence of meningitis. Bacterial culture of CSF was negative. One week after admission, he suddenly suffered from massive bleeding from the rectum, where a hemorrhagic ulcer caused by severe persistent constipation was observed. Contrast-enhanced CT scans and gadolinium-enhanced MR scans demonstrated a lumbar spinal epidural abscess, paraspinal muscle abscess, and cervical osteomyelitis. Streptococcus agalactiae, a bacterial species belonging to the group B streptococci, was isolated from pus obtained by needle puncture of the paraspinal muscle abscess. His entire condition was treated successfully with ampicillin and cefotaxime. Group B streptococci normally colonize the mucous membrane of the genital or lower gastrointestinal regions and rarely cause a spinal epidural abscess. However, in this case, the existence of a rectal ulcer probably made it possible for S. agalactiae to cause an infection of the epidural space or paraspinal muscles via the spinal valveless venous system named Batson's plexus communicating with the sacral, pelvic, and prostatic venous plexus. Our case indicated the importance of Batson's plexus in group B streptococcus infections surrounding the spinal canal and the necessity to explore for intrapelvic lesions including a rectal ulcer.

  13. Increase in specific density of levobupivacaine and fentanyl solution ensures lower incidence of inadequate block.

    PubMed

    Djeno, Ivana Tudorić; Duzel, Viktor; Ajduk, Marko; Oremus, Zrinka Safarić; Zupcić, Miroslav; Dusper, Silva; Jukić, Dubravko; Husedzinović, Ino

    2012-06-01

    The clinical presentation of a subarachnoid block (SAB) is dependent upon the intrathecal spread of local anesthetic (LA). Intrathecal distribution depends on the chemical and physical characteristics of LA, puncture site, technique used, patient anatomical characteristics and hydrodynamic properties of cerebrospinal fluid. We tried to determine whether a combined glucose/LA solution can render a clinically significant difference in sensory block distribution and motor block intensity.This was a controlled, randomized and double blinded study. The surgical procedures were stripping of the great or small saphenous vein and extirpation of remaining varicose veins. The study included 110 patients distributed into two groups: Hyperbaric (7.5 mg levobupivacaine (1.5 ml 0.5% Chirocaine) + 50 microg Fentanyl (0.5 ml Fentanil) and 1 ml 10% glucose (Pliva)) vs. Hypobaric (7.5 mg levobupivacaine (1.5 ml 0.5% Chirocaine) + 50 microg Fentanyl (0.5 ml Fentanil) and 1 ml 0.9% NaCl (Pliva, Zagreb)) adding to a total volume of 3.5 ml per solution. Spinal puncture was at L3-L4 level. Spinal block distribution was assessed in five minute intervals and intensity of motor block was assessed according to the modified Bromage scale. Pain was assessed with the Visual Analogue Scale. A statistically significant difference in sensory block distribution, motor block intensity and recovery time was established between hyperbaric and hypobaric solutions. By increasing the specific density of anesthetic solution, a higher sensory block, with lesser variability, a diminished influence of Body Mass Index, decreased motor block intensity and faster recovery time may be achieved.

  14. Spinal anaesthesia for caesarean section: comparison of 22-gauge and 25-gauge Whitacre needles with 26-gauge Quincke needles.

    PubMed

    Shutt, L E; Valentine, S J; Wee, M Y; Page, R J; Prosser, A; Thomas, T A

    1992-12-01

    We have studied 150 women undergoing elective Caesarean section under spinal anaesthesia. They were allocated randomly to have a 22-gauge Whitacre, a 25-gauge Whitacre or a 26-gauge Quincke needle inserted into the lumbar subarachnoid space. The groups were compared for ease of insertion, number of attempted needle insertions before identification of cerebrospinal fluid, quality of subsequent analgesia and incidence of postoperative complications. There were differences between groups, but they did not reach statistical significance. Postdural puncture headache (PDPH) was experienced by one mother in the 22-gauge Whitacre group, none in the 25-gauge Whitacre group and five in the 26-gauge Quincke group. Five of the six PDPH occurred after a single successful needle insertion. Seven of the 15 mothers in whom more than two needle insertions were made experienced backache, compared with 12 of the 129 receiving two or less (P < 0.001). We conclude that the use of 22- and 25-gauge Whitacre needles in elective Caesarean section patients is associated with a low incidence of PDPH and that postoperative backache is more likely when more than two attempts are made to insert a spinal needle.

  15. Study of post dural puncture headache with 27G Quincke & Whitacre needles in obstetrics/non obstetrics patients.

    PubMed

    Srivastava, Vibhu; Jindal, Parul; Sharma, J P

    2010-06-01

    The proposed study was carried out in the department of Anaesthesiology, Intensive care & Pain management, Himalayan Institute of Medical Sciences. Swami Rama Nagar, Dehradun. A total of 120 patients of ASA I & II obstetric & non-obstetric undergoing elective/emergency surgery under subarachnoid block were included under the study. To evaluate the frequency of PDPH during spinal anaesthesia using 27 gauge Quincke vs 27G whitacre needle in obstetric/non obstetric patient. In our study patients were in the age group of 15-75 years. Most of the patients in our study belong to ASA Grade I. There was 2%, 1%, 4% and 3% hypotension in-group A, B, C, D respectively. There was 2%, 4% shivering in-group A, C respectively and 1% each in group B, D. In our study failed spinal with 27G Quincke needle was in one case (3.33%) in-group C where successful subarachnoid was performed with a thicken spinal needle 23G Quincke. There was no incidence of PDPH in-group A and D, while 1 (2%) patient in-group B and 2 (4%) in group C. All the three patients were for lower section caesarean section and were young and had undergone more than one attempt to perform spinal block. The headache severity was from mild to moderate and no epidural blood patch was applied.

  16. Virtual reality-based simulators for spine surgery: a systematic review.

    PubMed

    Pfandler, Michael; Lazarovici, Marc; Stefan, Philipp; Wucherer, Patrick; Weigl, Matthias

    2017-09-01

    Virtual reality (VR)-based simulators offer numerous benefits and are very useful in assessing and training surgical skills. Virtual reality-based simulators are standard in some surgical subspecialties, but their actual use in spinal surgery remains unclear. Currently, only technical reviews of VR-based simulators are available for spinal surgery. Thus, we performed a systematic review that examined the existing research on VR-based simulators in spinal procedures. We also assessed the quality of current studies evaluating VR-based training in spinal surgery. Moreover, we wanted to provide a guide for future studies evaluating VR-based simulators in this field. This is a systematic review of the current scientific literature regarding VR-based simulation in spinal surgery. Five data sources were systematically searched to identify relevant peer-reviewed articles regarding virtual, mixed, or augmented reality-based simulators in spinal surgery. A qualitative data synthesis was performed with particular attention to evaluation approaches and outcomes. Additionally, all included studies were appraised for their quality using the Medical Education Research Study Quality Instrument (MERSQI) tool. The initial review identified 476 abstracts and 63 full texts were then assessed by two reviewers. Finally, 19 studies that examined simulators for the following procedures were selected: pedicle screw placement, vertebroplasty, posterior cervical laminectomy and foraminotomy, lumbar puncture, facet joint injection, and spinal needle insertion and placement. These studies had a low-to-medium methodological quality with a MERSQI mean score of 11.47 out of 18 (standard deviation=1.81). This review described the current state and applications of VR-based simulator training and assessment approaches in spinal procedures. Limitations, strengths, and future advancements of VR-based simulators for training and assessment in spinal surgery were explored. Higher-quality studies with patient-related outcome measures are needed. To establish further adaptation of VR-based simulators in spinal surgery, future evaluations need to improve the study quality, apply long-term study designs, and examine non-technical skills, as well as multidisciplinary team training. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. [Combined spinal-epidural anesthesia for cesarean section in a parturient with myotonic dystrophy].

    PubMed

    Mori, Kosuke; Mizuno, Ju; Nagaoka, Takehiko; Harashima, Toshiya; Morita, Sigeho

    2010-08-01

    Myotonic dystrophy (MD) is a muscle disorder characterized by progressive muscle wasting and weakness, and is the most common form of muscular dystrophy that begins in adulthood, often after pregnancy. MD might be related to occurrence of malignant hyperthermia. Therefore, the cesarean section is often performed for the parturient with MD. We had an experience of combined spinal-epidural anesthesia for cesarean section in a parturient complicated with MD. A 40-year-old woman had rhabdomyolysis caused by ritodrine at 15-week gestation and was diagnosed as MD by electromyography. Her first baby died due to respiratory failure fourth day after birth. She had hatchet face, slight weakness of her lower extremities, and easy fatigability. Her manual muscle test was 5/5 at upper extremities and 4/5 at lower extremities. She underwent emergency cesarean section for premature rupture of the membrane, weak pain during labor, and obstructed labor at 33-week gestation. We placed an epidural catheter from T12/L1 and punctured arachnoid with 25 G spinal needle. We performed spinal anesthesia using 0.5% hyperbaric bupivacaine 1.5 ml and epidural anesthesia using 2% lidocaine 6 ml. Her anesthetic level reached bilaterally to T7 and operation started 18 minutes after combined spinal-epidural anesthesia. Her baby was born 23 minutes after the anesthesia. As her baby was 1/5 at Apgar score, the baby was tracheally intubated and artificially ventilated. The cesarean section was finished in 33 minutes uneventfully. She had no adverse events and was discharged on the 8th postoperative day. Later her baby was diagnosed as congenital MD by gene analysis. Combined spinal-epidural anesthesia with the amide-typed local anesthetic agents could be useful and safe for cesarean section in the parturient with MD.

  18. The epidural needle guidance with an intelligent and automatic identification system for epidural anesthesia

    NASA Astrophysics Data System (ADS)

    Kao, Meng-Chun; Ting, Chien-Kun; Kuo, Wen-Chuan

    2018-02-01

    Incorrect placement of the needle causes medical complications in the epidural block, such as dural puncture or spinal cord injury. This study proposes a system which combines an optical coherence tomography (OCT) imaging probe with an automatic identification (AI) system to objectively identify the position of the epidural needle tip. The automatic identification system uses three features as image parameters to distinguish the different tissue by three classifiers. Finally, we found that the support vector machine (SVM) classifier has highest accuracy, specificity, and sensitivity, which reached to 95%, 98%, and 92%, respectively.

  19. [Acute non-traumatic myelopathy in children and adolescents].

    PubMed

    Arroyo, Hugo A

    2013-09-06

    The term 'acute myelopathies'--referred to a spinal cord dysfunction--represent a heterogeneous group of disorders with distinct etiologies, clinical and radiologic features, and prognoses. The objective of this review is to discuss the non-traumatic acute myelopathies. Acute myelopathy can be due to several causes as infective agents or inflammatory processes, such as in acute myelitis, compressive lesions, vascular lesions, etc. The clinical presentation is often dramatic with tetraparesis or paraparesis, sensory disturbances and bladder and/or bowel dysfunction. History and physical examination are used to localize the lesion to the root or specific level of the cord, which can guide imaging. Different syndromes are recognized: complete transverse lesion, central grey matter syndrome, anterior horn syndrome, anterior spinal artery syndrome, etc). The first priority is to rule out a compressive lesion. If a myelopathy is suspected, a gadolinium-enhanced MRI of the spinal cord should be obtained as soon as possible. If there is no structural lesion such as epidural blood or a spinal mass, then the presence or absence of spinal cord inflammation should be documented with a lumbar puncture. The absence of pleocytosis would lead to consideration of non inflammatory causes of myelopathy such as arteriovenous malformations, fibrocartilaginous embolism, or possibly early inflammatory myelopathy. In the presence of an inflammatory process (defined by gadolinium enhancement, cerebrospinal fluid pleocytosis, or elevated cerebrospinal fluid immunoglobulin index), one should determine whether there is an inflammatory or an infectious cause. Different virus, bacterias, parasites and fungi have to be considered as autoimmune and inflammatory diseases that involve the central nervous system.

  20. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  1. [Hypobaric 0.15% bupivacaine versus hyperbaric 0.5% bupivacaine for posterior (dorsal) spinal block in outpatient anorectal surgery.].

    PubMed

    Imbelloni, Luiz Eduardo; Vieira, Eneida Maria; Gouveia, M A; Netinho, João Gomes; Cordeiro, José Antonio

    2006-12-01

    The aim of this study was to study low dose hypobaric 0.15% bupivacaine and hyperbaric 0.5% bupivacaine in outpatient anorectal surgical procedures. Two groups of 50 patients, physical status ASA I and II, undergoing anorectal surgical procedures in a jackknife position, received 6 mg of hypobaric 0.15% bupivacaine in the surgical position (Group 1) or 6 mg of hyperbaric 0.5% bupivacaine in the sitting position for 5 minutes, after which they were placed in a jackknife position (Group 2). Sensitive and motor blockade, time of first urination, ambulation, complications, and the need for analgesics were evaluated. Patients were followed until the third postoperative day and questioned whether they experienced post-puncture headache or temporary neurological symptoms, and until the 30th day and questioned about permanent neurological complications. The test t Student, Mood's median, and Fisher Exact test were used for statistical analysis, and a p < 0.05 was considered significant. Every patient in Group 1 presented selective blockade of the posterior sacral nerve roots, while patients in Group 2 experienced blockade of the anterior and posterior nerve roots. Blockade was significantly higher in Group 1. Motor blockade was significantly less severe in Group 1. Forty-nine patients in Group 1 transferred to the stretcher unassisted while only 40 patients in Group 2 were able to do so. Recovery in Group 1 occurred in 105 +/- 25 minutes and in 95 +/- 15 minutes in Group 2, and this difference was not statistically significant. There were no hemodynamic changes, nausea or vomiting, urine retention, or post-puncture headache. Anorectal surgical procedures under spinal block with low dose bupivacaine, hyperbaric or hypobaric, can be safely done.

  2. Postdural puncture headache: comparison of 25-gauge Whitacre and Quincke needles.

    PubMed

    Buettner, J; Wresch, K P; Klose, R

    1993-01-01

    To evaluate the influence of the shape of the needle tip on postdural puncture headache (PDPH) independent of the needle diameter, a 25-gauge Whitacre and a 25-gauge Quincke needle were compared. In a prospective, randomized, double-blind fashion, the study was carried out on 400 patients who received spinal anesthesia for operations of the lower extremities. The 25-gauge Whitacre needle (group 1) and the 25-gauge Quincke needle (group 2) were randomly assigned to the patients, 200 in each group. Patients were interviewed postoperatively on days 1, 3, 5, and 7 using a standardized questionnaire. Only postural headache was defined as PDPH. The intensity of both postural and nonpostural headache were quantified using a 4-point rating scale and a visual analog pain scale (VAS). Statistical analysis was performed with parametric and nonparametric tests when appropriate, p < or = 0.05 was considered as significant. There were no differences in age and sex distribution between the two groups. Significantly more patients in group 2 (8.5%) complained of PDPH than in group 1 (3%, p < or = 0.02). Duration of PDPH ranged from 1-3 days (median: 1) in group 1, and from 1-9 days (median: 3) in group 2. This difference closely approached significance (p = 0.058). The mean maximal intensity of PDPH was comparable in both groups. Severe PDPH occurred only in two patients of group 2. One of them required a blood patch. With respect to the nonpostural headache, no significant differences were seen. The use of a conical tipped Whitacre needle results in significantly less PDPH compared to a standard Quincke spinal needle of the same size.

  3. Evaluation of Spontaneous Spinal Cerebrospinal Fluid Leaks Disease by Computerized Image Processing.

    PubMed

    Yıldırım, Mustafa S; Kara, Sadık; Albayram, Mehmet S; Okkesim, Şükrü

    2016-05-17

    Spontaneous Spinal Cerebrospinal Fluid Leaks (SSCFL) is a disease based on tears on the dura mater. Due to widespread symptoms and low frequency of the disease, diagnosis is problematic. Diagnostic lumbar puncture is commonly used for diagnosing SSCFL, though it is invasive and may cause pain, inflammation or new leakages. T2-weighted MR imaging is also used for diagnosis; however, the literature on T2-weighted MRI states that findings for diagnosis of SSCFL could be erroneous when differentiating the diseased and control. One another technique for diagnosis is CT-myelography, but this has been suggested to be less successful than T2-weighted MRI and it needs an initial lumbar puncture. This study aimed to develop an objective, computerized numerical analysis method using noninvasive routine Magnetic Resonance Images that can be used in the evaluation and diagnosis of SSCFL disease. Brain boundaries were automatically detected using methods of mathematical morphology, and a distance transform was employed. According to normalized distances, average densities of certain sites were proportioned and a numerical criterion related to cerebrospinal fluid distribution was calculated. The developed method was able to differentiate between 14 patients and 14 control subjects significantly with p = 0.0088 and d = 0.958. Also, the pre and post-treatment MRI of four patients was obtained and analyzed. The results were differentiated statistically (p = 0.0320, d = 0.853). An original, noninvasive and objective diagnostic test based on computerized image processing has been developed for evaluation of SSCFL. To our knowledge, this is the first computerized image processing method for evaluation of the disease. Discrimination between patients and controls shows the validity of the method. Also, post-treatment changes observed in four patients support this verdict.

  4. Pig lumbar spine anatomy and imaging-guided lateral lumbar puncture: a new large animal model for intrathecal drug delivery.

    PubMed

    Pleticha, Josef; Maus, Timothy P; Jeng-Singh, Christian; Marsh, Michael P; Al-Saiegh, Fadi; Christner, Jodie A; Lee, Kendall H; Beutler, Andreas S

    2013-05-30

    Intrathecal (IT) administration is an important route of drug delivery, and its modelling in a large animal species is of critical value. Although domestic swine is the preferred species for preclinical pharmacology, no minimally invasive method has been established to deliver agents into the IT space. While a "blind" lumbar puncture (LP) can sample cerebrospinal fluid (CSF), it is unreliable for drug delivery in pigs. Using computed tomography (CT), we determined the underlying anatomical reasons for this irregularity. The pig spinal cord was visualised terminating at the S2-S3 level. The lumbar region contained only small amounts of CSF found in the lateral recess. Additional anatomical constraints included ossification of the midline ligaments, overlapping lamina with small interlaminar spaces, and a large bulk of epidural adipose tissue. Accommodating the the pig CT anatomy, we developed a lateral LP (LLP) injection technique that employs advanced planning of the needle path and monitoring of the IT injection progress. The key features of the LLP procedure involved choosing a vertebral level without overlapping lamina or spinal ligament ossification, a needle trajectory crossing the midline, and entering the IT space in its lateral recess. Effective IT delivery was validated by the injection of contrast media to obtain a CT myelogram. LLP represents a safe and reliable method to deliver agents to the lumbar pig IT space, which can be implemented in a straightforward way by any laboratory with access to CT equipment. Therefore, LLP is an attractive large animal model for preclinical studies of IT therapies. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. The use of IV-tubing as a closed-suction drainage system during neurosurgical cases in Tanzania.

    PubMed

    Bonfield, Christopher M; Shabani, Hamisi K; Kanumba, Emmanuel S; Ellegala, Dilantha B; Nicholas, Joyce

    2013-01-01

    Commercial closed-suctions drainage systems are commonly used in the United States and many other countries for use in neurosurgical cases. However, in Tanzania and other developing nations with fewer resources, these are not available. This report explores another option for a closed-system drainage system utilizing inexpensive supplies found commonly in hospitals around the world. Sterile IV-tubing is cut, inserted into the wound, and brought out through an adjacent puncture incision. For suction, an empty plastic bottle can be attached to the tubing. The IV-tubing closed-suction drainage system was applied in both cranial and spinal neurosurgical procedures, including as subdural, subgaleal, epidural, and suprafacial drains. It maintained suction and was an adequate substitute when commercial drains are unavailable. This report illustrates how sterile IV-tubing can be adapted for use as a closed-drainage system. It utilizes inexpensive supplies commonly found in many hospitals throughout the world and can be applied to both cranial and spinal neurosurgical procedures.

  6. Spinal epidural hematomas: personal experience and literature review of more than 1000 cases.

    PubMed

    Domenicucci, Maurizio; Mancarella, Cristina; Santoro, Giorgio; Dugoni, Demo Eugenio; Ramieri, Alessandro; Arezzo, Maria Felice; Missori, Paolo

    2017-08-01

    OBJECTIVE The goal of this study was to identify factors that contribute to the formation of acute spinal epidural hematoma (SEH) by correlating etiology, age, site, clinical status, and treatment with immediate results and long-term outcomes. METHODS The authors reviewed their series of 15 patients who had been treated for SEH between 1996 and 2012. In addition, the authors reviewed the relevant international literature from 1869 (when SEH was first described) to 2012, collecting a total of 1010 cases. Statistical analysis was performed in 959 (95%) cases that were considered valid for assessing the incidence of age, sex, site, and clinical status at admission, correlating each of these parameters with the treatment results. Statistical analysis was also performed in 720 (71.3%) cases to study the incidence of etiological factors that favor SEH formation: coagulopathy, trauma, spinal puncture, pregnancy, and multifactorial disorders. The clinical status at admission and long-term outcome were studied for each group. Clinical status was assessed using the Neuro-Grade (NG) scale. RESULTS The mean patient age was 47.97 years (range 0-91 years), and a significant proportion of patients were male (60%, p < 0.001). A bimodal distribution has been reported for age at onset with peaks in the 2nd and 6th decades of life. The cause of the SEH was not reported in 42% of cases. The etiology concerned mainly iatrogenic factors (18%), such as coagulopathy or spinal puncture, rather than noniatrogenic factors (29%), such as genetic or metabolic coagulopathy, trauma, and pregnancy. The etiology was multifactorial in 11.1% of cases. The most common sites for SEH were C-6 (n = 293, 31%) and T-12 (n = 208, 22%), with maximum extension of 6 vertebral bodies in 720 cases (75%). At admission, 806 (84%) cases had moderate neurological impairment (NG 2 or 3), and only lumbar hematoma was associated with a good initial clinical neurological status (NG 0 or 1). Surgery was performed in 767 (80%) cases. Mortality was greater in patients older than 40 years of age (9%; p < 0.01). Sex did not influence any of these data (p > 0.05). CONCLUSIONS Factors that contribute to the formation of acute SEH are iatrogenic, not iatrogenic, or multifactorial. The treatment of choice is surgery, and the results of treatment are influenced by the patient's clinical and neurological status at admission, age, and the craniocaudal site.

  7. Preoperative Onyx embolization of hypervascular head, neck, and spinal tumors: experience with 100 consecutive cases from a single tertiary center.

    PubMed

    Rangel-Castilla, Leonardo; Shah, Ankit H; Klucznik, Richard Paul; Diaz, Orlando M

    2014-01-01

    Preoperative embolization of head, neck, and spinal tumors is frequently used to control tumor bleeding, reduce operative time, and achieve better resection. Numerous embolic materials have been used. The use of the liquid embolic agent Onyx is rapidly increasing but current experience is limited to small case series. Our purpose was to evaluate the indications, techniques, angiographic devascularization, blood loss, outcome, and general efficacy of preoperative tumor embolization with Onyx in a large series. Retrospective analysis of 100 consecutive cases of head, neck, and spinal tumors embolized with Onyx and prospective follow-up. 100 patients (63 women, 37 men) were included. Tumors included 39 meningiomas, 23 metastases, 16 parangliomas, five juvenile nasal angiofibromas, five giant cell bone tumors, three Ewing's sarcomas, three hemangiomas, three hemangioblastomas, two multiple myelomas, and one osteoblastoma. In all patients, angiographic analysis of the feeding arteries and branches was performed and all embolizations were completed in a single session. Additional materials were used in 28 patients. No mortality or major complications were observed. Minor complications were seen in 11 patients. 85 patients underwent surgery; 79 within the next 48 h and six of them 4-188 days after embolization. Embolization of intracranial, head, neck, and spinal tumors with Onyx is effective and safe by a transarterial route or by direct puncture. Onyx penetrates well into the tumor capillary with less arterial catheterization. Studies are necessary to establish long term utility in adjunct or palliative tumor embolization.

  8. The effects of subarachnoid administration of preservative-free S(+)-ketamine on spinal cord and meninges in dogs.

    PubMed

    Rojas, Alfredo Cury; Alves, Juliana Gaiotto; Moreira E Lima, Rodrigo; Esther Alencar Marques, Mariângela; Moreira de Barros, Guilherme Antônio; Fukushima, Fernanda Bono; Modolo, Norma Sueli Pinheiro; Ganem, Eliana Marisa

    2012-02-01

    The N-methyl-d-aspartate receptor antagonist ketamine and its active enantiomer, S(+)-ketamine, have been injected in the epidural and subarachnoid spaces to treat acute postoperative pain and relieve neuropathic pain syndrome. In this study we evaluated the effects of a single dose of preservative-free S(+)-ketamine, in doses usually used in clinical practice, in the spinal cord and meninges of dogs. Under anesthesia (IV etomidate (2 mg/kg) and fentanyl (0.005 mg/kg), 16 dogs (6 to 15 kg) were randomized to receive a lumbar intrathecal injection (L5/6) of saline solution of 0.9% (control group) or S(+)-ketamine 1 mg/kg(-1) (ketamine group). All doses were administered in a volume of 1 mL over a 10-second interval. Accordingly, injection solution ranged from 0.6% to 1.5%. After 21 days of clinical observation, the animals were killed; spinal cord, cauda equina root, and meninges were removed for histological examination with light microscopy. Tissues were examined for demyelination (Masson trichrome), neuronal death (hematoxylin and eosin) and astrocyte activation (glial fibrillary acidic protein). No clinical or histological alterations of spinal tissue or meninges were found in animals from either control or ketamine groups. A single intrathecal injection of preservative-free S(+)-ketamine, at 1 mg/kg(-1) dosage, over a concentration range of 6 to 15 mg/mL injected in the subarachnoid space in a single puncture, did not produce histological alterations in this experimental model.

  9. The effects of intrathecal administration of betamethasone over the dogs' spinal cord and meninges.

    PubMed

    Barros, Guilherme Antonio Moreira de; Marques, Mariângela Esther Alencar; Ganem, Eliana Marisa

    2007-01-01

    To determinate the potential clinical and histological changes due the injection of betamethasone, when administered into the canine intrathecal space. Twenty one animals were included in a random and blind manner in the study. After general anesthesia, intrathecal puncture was performed and 1 ml of the random solution was injected. The G1 dogs received 0.9% saline solution, the G2 dogs received 1.75 mg betamethasone and the G3 dogs received 3.5 mg of betamethasone. The animals were clinically evaluated for 21 days and then sacrificed. The lumbar and sacral portions of the spinal cord were removed for light microscopy histological analyses. No clinical changes were observed in any of the animals included in this study. No histological changes were observed in G1 animals. Inflammatory infiltration was observed in two dogs, one in G2, another in G3. Hemorrhage and necrosis were also seen in the G2 dog which inflammatory infiltration was detected. In other two dogs, one from G2 and another from G3, there was discreet fibrosis and thickness of the arachnoid layer which was focal in one and diffuse in the other. Intrathecal administration of betamethasone caused histological changes in the spinal cord and meninges in some of the dogs involved in this study.

  10. Older adults’ attitudes toward noncompetent subjects participating in Alzheimers research

    PubMed Central

    Karlawish, Jason; Rubright, Jonathan; Casarett, David; Cary, Mark; TenHave, Thomas; Sankar, Pamela

    2008-01-01

    Objective Since research that enrolls noncompetent patients with Alzheimers disease and does not present potential benefit to subjects is the source of substantial ethical controversy, we assessed willingness to have a proxy for research decision making, and, for each of two Alzheimers disease biomarker studies (minimal risk blood draw and a greater than minimal risk blood draw and lumbar puncture), willingness to grant an advance consent, and willingness to grant a proxy leeway over advance consent. Methods Face to face survey of 538 persons 65 and over who resided in the Southeastern Pennsylvania region Results The majority 83% (445/538) granted advance consent to a blood draw study and nearly half to a blood draw plus lumbar puncture 259 (48%). Most persons (96%) were willing to identify a proxy for research decision making and most were willing to grant their proxy leeway over their advance consent: blood draw 434 (81%), and 375 (70%) blood draw plus lumbar puncture. Combining the preferences for advance consent and leeway, the proportion who would permit being enrolled in the blood draw and spinal fluid sample studies were, respectively, 92% (497/538) and 75% (404/538). Multi-variate models showed that willingness to be enrolled in research was most strongly associated with a favorable attitude about biomedical research. Conclusions Older adults generally support enrolling noncompetent persons with Alzheimers disease into research that does not present a benefit to subjects. Willingness to grant their proxy leeway over advance consent and a favorable attitude about biomedical research substantially explain this willingness. PMID:18923066

  11. PDPH in obstetric anesthesia: comparison of 24-gauge Sprotte and 25-gauge Quincke needles and effect of subarachnoid administration of fentanyl.

    PubMed

    Devcic, A; Sprung, J; Patel, S; Kettler, R; Maitra-D'Cruze, A

    1993-01-01

    Postdural puncture headache (PDPH) is a frequent complication of spinal anesthesia. Some investigators have recommended the use of the Sprotte needle to reduce the incidence of this serious complication. This study prospectively compared the incidence of PDPH with two spinal needles of different size and design: the 24-gauge Sprotte (noncutting point) versus the 25-gauge Quincke (diamond, cutting point). The hypothesis that subarachnoid fentanyl will reduce the incidence of PDPH, as suggested in the literature, was also studied. Only patients for emergency or elective cesarean delivery were studied. One hundred ninety four patients were randomly assigned to receive spinal anesthesia with one of the two needles (Sprotte, n = 96; Quincke, n = 98). Simultaneously, each patient was assigned to receive hyperbaric 0.75% bupivacaine local anesthetic or a combination of the same concentration of local anesthetic with 20 micrograms of fentanyl (Sprotte with fentanyl, n = 47; Sprotte without fentanyl, n = 49; Quincke with fentanyl, n = 49; Quincke without fentanyl, n = 49). All patients were evaluated during the first 4 postoperative days, and follow-up telephone interviews were conducted 3 weeks after discharge. Four patients (4.2%) in the Sprotte group and seven (7.1%) in the Quincke group developed PDPH. Three out of four patients with headache in the Sprotte and four out of seven in the Quincke group received fentanyl as an adjunct for spinal anesthesia. Two patients in the Sprotte group required an epidural blood patch as a therapy for PDPH. Two patients in the Quincke group had severe headache and required an epidural blood patch. In the current study, the use of the 24-gauge Sprotte spinal needle resulted in a low incidence of severe PDPH, but was not significantly different when compared with the use of a 25-gauge Quincke needle (oriented parallel to the longitudinal dural fibers). The addition of fentanyl to hyperbaric bupivacaine spinal anesthesia did not reduce the risk of PDPH.

  12. Comparison of Hemodynamic Changes in Unilateral Spinal Anesthesia Versus Epidural Anesthesia Below the T10 Sensory Level in Unilateral Surgeries: a Double-Blind Randomized Clinical Trial

    PubMed Central

    Kiasari, Alieh Zamani; Babaei, Anahita; Alipour, Abbas; Motevalli, Shima; Baradari, Afshin Gholipour

    2017-01-01

    Background: Unilateral spinal anesthesia is used to limit the spread of block. The aim of the present study was to compare hemodynamic changes and complications in unilateral spinal anesthesia and epidural anesthesia below the T10 sensory level in unilateral surgeries. Materials and Methods: In this double-blind randomized clinical trial in total 120 patients were randomly divided into a unilateral spinal anesthesia group (Group S) and an epidural anesthesia group (Group E). Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and heart rates were measured before and immediately after the administration of spinal or epidural anesthesia and then at 5-, 10-, 15-, 20-, 25-, and 30-min intervals. The rates of prescribed ephedrine and intraoperative respiratory arrest were recorded, in addition to postoperative nausea and vomiting, puncture headaches, and back pain during the first 24 h after the surgery. Results: SBP, DBP, and MAP values initially showed a statistically significant downward trend in both groups (p = 0.001). The prevalence of hypotension in Group S was lower than in Group E, and the observed difference was statistically significant (p < 0.0001). The mean heart rate change in Group E was greater than in Group S, although the difference was not statistically significant (p = 0.68). The incidence of prescribed ephedrine in response to a critical hemodynamic situation was 5.1% (n = 3) and 75% (n = 42) in Group S and Group E, respectively (p = 0.0001). The incidence of headaches, back pain, and nausea/vomiting was 15.3%, 15.3%, and 10.2% in Group S and 1.8%, 30.4%, and 5.4% in Group E (p = 0.017, 0.07, and 0.49, respectively). Conclusion: Hemodynamic stability, reduced administration of ephedrine, a simple, low-cost technique, and adequate sensory and motor block are major advantages of unilateral spinal anesthesia. PMID:28974849

  13. An in vitro study of dural lesions produced by 25-gauge Quincke and Whitacre needles evaluated by scanning electron microscopy.

    PubMed

    Reina, M A; de Leon-Casasola, O A; Lopez, A; De Andres, J; Martin, S; Mora, M

    2000-01-01

    A study using scanning electron microscopy showed that although the laminas forming the dura mater are concentric and parallel to the surface of the medulla, the fiber layers' orientations are different in each sub-lamina, dispelling the conventional knowledge that all the fibers of the dura are arranged in a parallel direction. Thus, this study evaluated the dural lesions produced by Whitacre and Quincke spinal needles in the external and internal surface of the dura mater of the lower spine area in an attempt to gain more insight into the pathophysiology of postdural puncture headaches (PDPH). The T11-L4 dural membranes from 5 fresh (immediately after extraction of organs for transplantation), male patients declared brain dead, ages 23, 46, 48, 55, and 60 years, were excised by anterior laminectomy. Morphologic orientation of the membrane and normal pH were maintained with an apparatus designed for this purpose. One hundred punctures (20 on each sample) at 90-degree angles were done with a new needle each time, 50 with 25-gauge Whitacre and 50 with 25-gauge Quincke needles. Half of the punctures with the Quincke needles were done with the bevel in parallel direction to the axis of the spinal cord, and the rest with the bevel perpendicular to it. Fixation in solutions of 2.5% glutaraldehyde phosphate buffer, followed by dehydration with acetone, was done 15 minutes after the punctures. After acetone was removed at ideal conditions of temperature and pressure, the specimens were then metallized with carbon followed by gold and inspected under a scanning electron microscope. Twenty-five of the Whitacre and 23 of the Quincke punctures were found for evaluation. There were no differences in the cross-sectional area of the punctures produced by the Whitacre or Quincke needles on the dura. The area of the dural lesions produced by 25-gauge Quincke needles, 15 minutes after they have been withdrawn, was 0.023 mm2 (confidence interval [CI] 95%, 0.015 to 0.027) in the external aspect (epidural surface) and 0.034 mm2 (CI 95%, 0.018 to 0.051) in the internal aspect (arachnoid surface) of the dural sac. The area of the lesions produced by the 25-gauge Whitacre needles was 0.026 mm2 (CI 95%, 0.019 to 0.032) and 0.030 mm2 (CI 95%, 0.025 to 0.036) in the external and internal surfaces of the dural sac, respectively. There were no significant differences in the cross-sectional areas of the punctures produced by the 25-gauge Whitacre or 25-gauge Quincke needles. Moreover, with Quincke needles the dural lesions closed in an 88.3% (CI 95%, 86.3 to 92.4) and 82.7% (CI 95%, 74.1 to 90.9) of their original sizes in the epidural and arachnoid surfaces, respectively. With Whitacre needles, the closure occurred in an 86.8% (CI 95%, 83.8 to 90.3) and 84.8% (CI 95% 81.7 to 87.3) in the dural and arachnoid surfaces, respectively. However, there were differences in the morphology of the lesions. The Whitacre needles produced coarse lesions with significant destruction in the dura's fibers while the Quincke needles produced a 'U'-shaped lesion (flap) that mimics the opened lid of a tin can, regardless of the tip's direction. The needles produced lesions in the dura with different morphology and characteristics. Lesions with the Quincke needles resulted in a clean-cut opening in the dural membrane while the Whitacre needle produced a more traumatic opening with tearing and severe disruption of the collagen fibers. Thus, we hypothesized that the lower incidence of PDPH seen with the Whitacre needles may be explained, in part, by the inflammatory reaction produced by the tearing of the collagen fibers after dural penetration. This inflammatory reaction may result in a significant edema which may act as a plug limiting the leakage of cerebrospinal fluid.

  14. A clinical evaluation of four non-Luer spinal needle and syringe systems.

    PubMed

    Kinsella, S M; Goswami, A; Laxton, C; Kirkham, L; Wharton, N; Bowen, M

    2012-11-01

    We performed an evaluation of non-Luer spinal devices supplied by four manufacturers or suppliers: Polymedic; Pajunk; Sarstedt; and Smiths. For each supplier, 100 evaluations were performed using a 25-G 90-mm spinal needle, 3-ml syringe, 5-ml syringe and filter needle; for comparison, 100 evaluations were performed with our standard Luer equipment. The non-Luer devices were associated with more qualitative problems compared with the Luer devices, for example, poor feel of dural puncture (9-32% vs 10%, respectively), poor observation of cerebrospinal fluid in the hub (3-27% vs 0%), and connection problem of the syringe to the spinal needle (7-33% vs 0%). There was also more frequent failure to achieve the spinal injection due to equipment-related causes (4-7% vs 0%, respectively). Median (IQR [range]) numeric satisfaction scores for the spinal needles were: Luer 10 (9-10 [7-10]); Polymedic 7 (4-8 [0-10]; Pajunk 7 (5-8 [0-10]); Sarstedt 7 (6-8 [0-10]); and Smiths 9 (7-10 [0-10]) (p<0.0001). Satisfaction scores for all spinal equipment were: Luer 10 (9-10 [5-10]); Polymedic 8 (6-8 [0-10]); Pajunk 7 (5-7 [1-9]); Sarstedt 8 (6-8 [0-10]); and Smiths 8 (8-9 [2-10]) (p<0.0001). Between 21% and 75% of non-Luer evaluations were rated with satisfaction worse than the usual Luer needle compared with 0-10% rated better, depending on the needle type. Between 22% and 76% of non-Luer evaluations were rated with satisfaction worse than the usual Luer equipment compared with 0-14% rated better. Specific concerns included poor feel of tissue planes and observation of cerebrospinal fluid (Polymedic), difficulty with connection of the syringe to the spinal needle and trocar removal (Pajunk), poor feel of tissue planes and needle flexibility (Sarstedt) and difficulty with connection of the syringe to the spinal needle (Smiths). We could not demonstrate a short-term learning curve for the new devices. Decisions on purchasing and implementation of the new non-Luer equipment will have to acknowledge that clinicians may have greater technical problems and reduced satisfaction compared with the current equipment. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  15. [Application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance].

    PubMed

    Jin, Yang-Hui; Shi, Shi-Yuan; Zheng, Qi; Shen, Jian; Ying, Xiao-Zhang; Wang, Yi-Fan

    2017-09-25

    To investigate the application value of Xpert MTB/RIF in diagnosis of spinal tuberculosis and detection of rifampin resistance. The 109 pus specimens were obtained from patients who were primaryly diagnosed as spinal tuberculosis. All of the pus specimens were detected by acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay to definite the differences in sensitivity and specificity of mycobacterium tuberculosis among detecting methods. Pus specimens obtained by different methods were deteceded by MTB/RIF test to analyze the self-influence on Xpert MTB/RIF test. The result of liquid fast culturing by BACTEC MGIT 960 was used as the gold standard; and the value of Xpert MTB/RIF assay in detecting rifampin resistance was analyzed. The sensitivity of acid-fast stain, liquid fast culturing by BACTEC MGIT 960 and Xpert MTB/RIF assay were 25.92%, 48.15%, 77.78%, respectively. The sensitivity of pus specimens obtained from open surgery, ultrasound positioning puncture and biopsy the sensitivity were 83.78%, 76.47%, 44.68% respectively deteceded by MTB/RIF test. According to the gold standard of the results of liquid fast culturing by BACTEC MGIT 960 assay, the sensitivity and specificity of Xpert MTB/RIF assay in detecting rifampin resistance were 80%(4/5) and 90.70%(39/43), respectively. Xpert MTB/RIF assay has higher value in diagnosis of spinal tuberculosi, and also can detect rifampin resistance. The number of mycobacterium tuberculosis in pus specimens has a great influence in the sensitivity of Xpert MTB/RIF assay.

  16. [Headhache secondary to intracranial hypotension in a Lumbar Spinal Stenosis Surgery].

    PubMed

    Hidalgo-Mendía, Begoña; Angulo-Tabernero, Marina; Jaroid-Audes, Ricardo; Untoria-Agustín, Carmen; Rivero-Zelada, David

    2016-01-01

    Intracraneal hypotension headache is a well known syndrome in neurosurgery practice. In most cases cerebrospinal fluid leaks are caused by medical interventions, such as lumbar puncture, peridural anesthesia and surgical interventions on the spine. Clinical symptoms tipically show orthostatic headache that resolves in supine position, and other symptoms like neck tightness, vertigo and diplopia. RMI diagnostic confirms paquimeningeal enhancement and subdural hygromas. Conservative treatment usually includes bed resting, hydratation and administration of caffeine or glucocorticoids, resolving spontaneously in one to four months. The importance of the diagnosis lies in the differential diagnosis with other causes of headache, as symptomatic limiting factor in the rehabilitation of the patient and the same favorable prognosis.

  17. Central nervous system complications of non-Hodgkin's lymphoma. The potential role for prophylactic therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, R.C.; Howser, D.M.; Anderson, T.

    1979-03-01

    In 38 patients with non-Hodgkin's lymphoma, involvement of the central nervous system (CNS) by malignant lymphoma developed during an eight year period. All patients had lymphomatous meningitis; clinical involvement of the spinal nerves or cranial nerves suggested the diagnosis. Spinal fluid was abnormal in 97% of the patients although a positive cytology could be documented in only 67% by lumbar puncture. The histology in 82% of the patients was diffuse. Involvement of the CNS in nodular lymphoma was uncommon (3%), and the histology in virtually all of these patients had converted to diffuse. At the time of diagnosis of CNSmore » disease, 95% of the patients had other evidence of advanced disease; 66% had bone marrow involvement. In only 18% of the patients did CNS disease develop while they werin clinical remission. Eighty-five percent of the patients treated with whole brain irradiation and intrathecal chemotherapy had a good clinical response. Knowledge of these risk factors permits definition of a group of patients who may benefit from CNS prophylaxis.« less

  18. Aneurysm of the intradural artery of Adamkiewicz treated with muslin wrapping: technical case report.

    PubMed

    Vishteh, A G; Brown, A P; Spetzler, R F

    1997-01-01

    An exceedingly rare, isolated spinal arterial aneurysm and its management are presented. A 30-year-old man who presented with severe lower back pain and headache underwent a computed tomographic study of his head that disclosed nothing abnormal and a lumbar puncture that revealed bloody, xanthochromic cerebrospinal fluid. The findings from cerebral angiography were normal, and the results from spinal angiography were consistent with a diagnosis of an aneurysm of the artery of Adamkiewicz. A transthoracic approach with a partial T11 vertebrectomy gained exposure to this anteriorly located lesion. A fusiform aneurysm of the intradural portion of the artery of Adamkiewicz was discovered. Excision of the aneurysm with a vascular bypass was deemed impossible. The lesion was treated with muslin wrapping. One year after surgery, the patient remains at his baseline neurological condition. A review of the literature revealed only one other reported case of a ruptured aneurysm of the artery of Adamkiewicz, which was discovered postmortem. Therefore, this case represents the first report of a diagnosed and treated artery of Adamkiewicz aneurysm.

  19. Retrospective analysis of obstetric and anesthetic management of patients with placenta accreta spectrum disorders.

    PubMed

    Riveros-Perez, Efrain; Wood, Cristina

    2018-03-01

    To assess the management and maternal outcomes of placenta accreta spectrum (PAS) disorders. A retrospective chart review was conducted of patients diagnosed with PAS disorders (placenta creta, increta, or percreta) who were treated at a US tertiary care center between February 1, 2011, and January 31, 2016. Obstetric management, anesthetic management, and maternal outcomes were analyzed. A total of 43 cases were identified; placenta previa was diagnosed among 33 (77%). Median age was 33 years (range 23-42). Median blood loss was 1500 mL (interquartile range 1000-2500); blood loss was greatest among the 10 patients with placenta percreta (3250 mL, interquartile range 2200-6000). Transfusion of blood products was necessary among 14 (33%) patients, with no difference in frequency according to the degree of placental invasion (P=0.107). Surgical complications occurred among 10 (23%) patients. Overall, 30 (70%) patients received combined spinal-epidural plus general anesthesia, 4 (9%) received only general anesthesia, and 9 (21%) underwent surgery with combined spinal-epidural anesthesia. One patient experienced difficult airway and another experienced accidental dural puncture. Placenta previa and accreta coexist in many patients, leading to substantial bleeding related to the degree of myometrial invasion. An interdisciplinary team approach plus the use of combined spinal-epidural anesthesia, transitioning to general anesthesia, were advisable and safe. © 2017 International Federation of Gynecology and Obstetrics.

  20. Fluoroscopically Guided Epidural Injections of the Cervical and Lumbar Spine.

    PubMed

    Shim, Euddeum; Lee, Joon Woo; Lee, Eugene; Ahn, Joong Mo; Kang, Yusuhn; Kang, Heung Sik

    2017-01-01

    Advances in imaging and the development of injection techniques have enabled spinal intervention to become an important tool in managing chronic spinal pain. Epidural steroid injection (ESI) is one of the most widely used spinal interventions; it directly delivers drugs into the epidural space to relieve pain originating from degenerative spine disorders-central canal stenoses and neural foraminal stenoses-or disk herniations. Knowledge of the normal anatomy of the epidural space is essential to perform an effective and safe ESI and to recognize possible complications. Although computed tomographic (CT) or combined CT-fluoroscopic guidance has been increasingly used in ESI, conventional fluoroscopic guidance is generally performed. In ESI, drugs are delivered into the epidural space by interlaminar or transforaminal routes in the cervical spine or by interlaminar, transforaminal, or caudal routes in the lumbar spine. Epidurography is usually performed before drug delivery to verify the proper position of the needle in the epidural space. A small amount of contrast agent is injected with fluoroscopic guidance. Familiarity with the findings on a typical "true" epidurogram (demonstrating correct needle placement in the epidural space) permits proper performance of ESI. Findings on "false" epidurograms (demonstrating incorrect needle placement) include muscular staining and evidence of intravascular injection, inadvertent facet joint injection, dural puncture, subdural injection, and intraneural or intradiscal injection. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on December 22, 2016.

  1. Grading of severity of postdural puncture headache after 27-gauge Quincke and Whitacre needles.

    PubMed

    Corbey, M P; Bach, A B; Lech, K; Frørup, A M

    1997-06-01

    Small-gauge needles are reported to have a low incidence of complications. Pencil-point needles are associated with a lower frequency of postdural puncture headache (PDPH), but a higher failure rate than Quincke needles. The incidence of PDPH was investigated in 200 patients under the age of 45, undergoing day-care surgery, after spinal anaesthesia with either 27-gauge Quincke or Whitacre needle. The severity of headache was graded as I (mild), II (moderate) or III (severe) using a grading system based on the visual analogue scale (VAS) associated with a functional rating (FG). The frequency of PDPH following the Whitacre needle was 0% and 5.6% after the Quincke needle (P = 0.05). Two PDPHs were assessed as grade III, and three as grade II. All PDPHs occurred when the Quincke needle bevel was withdrawn perpendicular to the dural fibres following parallel insertion. No PDPH occurred when the bevel was inserted and removed parallel to the dural fibres (P < 0.05). There was no statistical difference (P > 0.08) in the incidence of PDPH and postdural puncture-related headaches (PDPR-H) in patients with recurrent headaches or migraine compared to patients with no previous history of headaches. We conclude that the 27-gauge Whitacre needle is the 'needle of choice' in patients with normal body stature. The incidence of PDPH following Quincke needles may not only be affected by the direction of the bevel during insertion but also during removal. Statistically, there was no gender variation in PDPH in this study (P = 0.5). A previous history of recurrent headache or migraine does not predispose to PDPH.

  2. Do the gaps in the ligamentum flavum in the cervical spine translate into dural punctures? An analysis of 4,396 fluoroscopic interlaminar epidural injections.

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Cash, Kimberly A; Pampati, Vidyasagar

    2015-01-01

    Cervical interlaminar epidural injections are performed frequently in managing chronic neck and upper extremity pain, although less commonly than lumbar interlaminar epidural injections. Recently, the US Food and Drug Administration warnings and safeguards to prevent neurologic complications. These were developed by the Multi-Society Pain Workgroup have taken center stage for all types of epidural injections, including cervical interlaminar epidural injections. The recommendations of safeguards to prevent neurologic complications after epidural steroid injections include that cervical interlaminar epidural injections must be performed utilizing fluoroscopy with anteroposterior, lateral, or oblique views with injection of contrast medium and that entry be limited to the C7-T1 epidural space or occasionally the C6-C7 with requirements for magnetic resonance imaging assessment of the epidural space. To assess the incidence of dural puncture associated with fluoroscopically directed cervical interlaminar epidural injections. A retrospective assessment of patients undergoing cervical interlaminar epidural injections from January 2013 through February 2015. A private interventional pain management practice; a specialty referral center in the United States. The data were collected for 4,396 consecutive cervical interlaminar epidural injections performed from January 2013 through February 2015. The procedures were all performed under fluoroscopic visualization under posteroanterior view with contrast medium injection with lateral view confirmation when indicated. The procedures were performed by one of 2 physicians; the dural puncture and subsequent postoperative complications with level of epidural entry were determined. The outcome was assessment of dural puncture. A review of multiple manuscripts showed that defects in the ligamentum flavum may extend to as much as 100% of the population. However, it also has been shown that among the levels with a gap, the location of a gap in the caudal third of the ligamentum flavum was more frequent than in the middle or cephalic portion of the ligamentum flavum. Among the 4,396 epidural injections performed at C7-T1, C6-C7, and C5-C6, 1,227 were performed at C7-T1; 1,835 were performed at C6-C7; and 1,334 were performed at C5-C6. Dural punctures were observed in 1.8% (24 procedures) at the C5-C6 level entry; 0.87% (16 procedures) at the C6-C7 level entry; and 1.71% (21 procedures) at the C7-T1 level. There was no significant difference among the entry levels. No complications or spinal cord damage or postdural puncture headache were observed. The limitations of this report include that it is an assessment by only 2 well experienced physicians, even though it included a relatively large number of patients. This study illustrates that dural puncture is equally prevalent, though very rare, irrespective of the needle entry level into the epidural space, with an overall dural puncture rate of 1.4%, with 1.8% at the C5-C6 level, 0.87% at the C6-C7 level, and 1.71% at the C7-T1 level. Based on the present literature, it appears that performing the procedure by inserting the needle into the cephalic portion of the intervertebral space rather than the caudal portion may be safer.

  3. Spinal anaesthesia with a micro-catheter in high-risk patients undergoing colorectal cancer and other major abdominal surgery.

    PubMed

    Kumar, Chandra M; Corbett, William A; Wilson, Robert G

    2008-08-01

    Extended spinal anaesthesia using a spinal micro-catheter was used as a primary method of anaesthesia for elective colorectal cancer surgery in 68 high risk patients over a 14-year period in our institution. The technique was also useful in eight elective and 13 emergency abdominal surgeries. All patients suffered from severe chronic obstructive airway disease requiring multiple inhalers and drugs (ASA III). Thirty nine of these patients also suffered from angina, myocardial infarction, diabetes and other systemic diseases (ASA IV). Surgery included right hemicolectomy, left hemicolectomy, total colectomy, sigmoid colectomy, Hartman's resection, anterior resection of rectum, abdominoperineal resection, cholecystectomy (open and laparoscopic) and obstructed inguinal hernia requiring laparotomy. Spinal anaesthesia was performed under strict aseptic conditions with a 22 gauge spinal needle with a mixture consisting of 2.75ml of 0.5% heavy bupivacaine and 0.25ml of fentanyl (25microg). This was followed by placement of a spinal micro-catheter and the duration of anaesthesia was extended by intermittent injection of 0.5% isobaric bupivacaine. Brief hypotension occurred in 12.4% of patients during the establishment of anaesthetic block height to T6-7 and was duly treated with intravenous administration of fluid and ephedrine hydrochloride. Good anaesthesia resulted in all patients except for brief discomfort in some patients during hemicolectomy surgery possibly due to the dissection and traction on the peritoneum causing irritation to the diaphragm. The use of sedation was avoided. General anaesthesia was administered in one patient and this patient required postoperative ventilation and cardiovascular support in the Intensive Care Unit. The spinal micro-catheter was removed at the end of surgery. Postoperative pain relief was obtained by administering intravenous morphine through a patient controlled analgesia machine in the critical care ward area (High Dependency Unit). There was a low incidence of minor postoperative side effects such as nausea (14.6%), vomiting (7.9%), minor post dural puncture headache (5.6%) and pruritus (5.6%). We conclude that spinal anaesthesia with a micro-catheter may be used as a primary method of anaesthesia for colorectal cancer surgery and other major abdominal surgery in high-risk patients for whom general anaesthesia would be associated with higher morbidity and mortality.

  4. Imaging Features of the Brain, Cerebral Vessels and Spine in Pediatric Tuberculous Meningitis with Associated Hydrocephalus

    PubMed Central

    Rohlwink, Ursula K; Kilborn, Tracy; Wieselthaler, Nicky; Banderker, Ebrahim; Zwane, Eugene; Figaji, Anthony A.

    2016-01-01

    Background Pediatric tuberculous meningitis leads to high rates of mortality and morbidity. Prompt diagnosis and initiation of treatment are challenging; imaging findings play a key role in establishing the presumptive diagnosis. General brain imaging findings are well reported; however, specific data on cerebral vascular and spinal involvement in children are sparse. Methods This prospective cohort study examined admission and follow up computed tomography brain scans and magnetic resonance imaging scans of the brain, cerebral vessels (magnetic resonance angiogram) and spine at 3 weeks in children treated for tuberculous meningitis with hydrocephalus (inclusion criteria). Exclusion criteria were no hydrocephalus on admission, treatment of hydrocephalus or commencement of anti-TB treatment before study enrolment. Imaging findings were examined in association with outcome at 6 months. Results Forty-four patients (median age 3.3 [0.3-13.1] years) with definite (54%) or probable tuberculous meningitis were enrolled. Good clinical outcome was reported in 72%; the mortality rate was 16%. Infarcts were reported in 66% of patients and were predictive of poor outcome. Magnetic resonance angiogram abnormalities were reported in 55% of patients. Delayed tuberculomas developed in 11% of patients (after starting treatment). Spinal pathology was more common than expected, occurring in 76% of patients. Exudate in the spinal canal increased the difficulty of lumbar puncture and correlated with high cerebrospinal fluid protein content. Conclusion Tuberculous meningitis involves extensive pathology in the central nervous system. Severe infarction was predictive of poor outcome although this was not the case for angiographic abnormalities. Spinal disease occurs commonly and has important implications for diagnosis and treatment. Comprehensive imaging of the brain, spine and cerebral vessels adds insight into disease pathophysiology. PMID:27213261

  5. Imaging Features of the Brain, Cerebral Vessels and Spine in Pediatric Tuberculous Meningitis With Associated Hydrocephalus.

    PubMed

    Rohlwink, Ursula K; Kilborn, Tracy; Wieselthaler, Nicky; Banderker, Ebrahim; Zwane, Eugene; Figaji, Anthony A

    2016-10-01

    Pediatric tuberculous meningitis (TBM) leads to high rates of mortality and morbidity. Prompt diagnosis and initiation of treatment are challenging; imaging findings play a key role in establishing the presumptive diagnosis. General brain imaging findings are well reported; however, specific data on cerebral vascular and spinal involvement in children are sparse. This prospective cohort study examined admission and followed up computed tomography brain scans and magnetic resonance imaging scans of the brain, cerebral vessels (magnetic resonance angiogram) and spine at 3 weeks in children treated for TBM with hydrocephalus (HCP; inclusion criteria). Exclusion criteria were no HCP on admission, treatment of HCP or commencement of antituberculosis treatment before study enrollment. Imaging findings were examined in association with outcome at 6 months. Forty-four patients (median age 3.3 [0.3-13.1] years) with definite (54%) or probable TBM were enrolled. Good clinical outcome was reported in 72%; the mortality rate was 16%. Infarcts were reported in 66% of patients and were predictive of poor outcome. Magnetic resonance angiogram abnormalities were reported in 55% of patients. Delayed tuberculomas developed in 11% of patients (after starting treatment). Spinal pathology was more common than expected, occurring in 76% of patients. Exudate in the spinal canal increased the difficulty of lumbar puncture and correlated with high cerebrospinal fluid protein content. TBM involves extensive pathology in the central nervous system. Severe infarction was predictive of poor outcome although this was not the case for angiographic abnormalities. Spinal disease occurs commonly and has important implications for diagnosis and treatment. Comprehensive imaging of the brain, spine and cerebral vessels adds insight into disease pathophysiology.

  6. Anesthetic management of super-morbidly obese parturients for cesarean delivery with a double neuraxial catheter technique: a case series.

    PubMed

    Polin, C M; Hale, B; Mauritz, A A; Habib, A S; Jones, C A; Strouch, Z Y; Dominguez, J E

    2015-08-01

    Parturients with super-morbid obesity, defined as body mass index greater than 50kg/m(2), represent a growing segment of patients who require anesthetic care for labor and delivery. Severe obesity and its comorbid conditions place the parturient and fetus at greater risk for pregnancy complications and cesarean delivery, as well as surgical and anesthetic complications. The surgical approach for cesarean delivery in these patients may require a supra-umbilical vertical midline incision due to a large pannus. The dense T4-level of spinal anesthesia can cause difficulties with ventilation for the obese patient during the procedure, which can be prolonged. Patients also may have respiratory complications in the postoperative period due to pain from the incision. We describe the anesthetic management of three parturients with body mass index ranging from 73 to 95kg/m(2) who had a cesarean delivery via a supra-umbilical vertical midline incision. Continuous lumbar spinal and low thoracic epidural catheters were placed in each patient for intraoperative anesthesia and postoperative analgesia, respectively. Continuous spinal catheters were dosed with incremental bupivacaine boluses to achieve surgical anesthesia. In one case, the patient required respiratory support with non-invasive positive pressure ventilation. Two cases were complicated by intraoperative hemorrhage. All patients had satisfactory postoperative analgesia with a thoracic epidural infusion. None suffered postoperative respiratory complications or postdural puncture headache. The use of a continuous lumbar spinal catheter and a low thoracic epidural provides several advantages in the anesthetic management of super-morbidly obese parturients for cesarean delivery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Ligand requirements for involvement of PKCε in synergistic analgesic interactions between spinal μ and δ opioid receptors.

    PubMed

    Schuster, D J; Metcalf, M D; Kitto, K F; Messing, R O; Fairbanks, C A; Wilcox, G L

    2015-01-01

    We recently found that PKCε was required for spinal analgesic synergy between two GPCRs, δ opioid receptors and α2 A adrenoceptors, co-located in the same cellular subpopulation. We sought to determine if co-delivery of μ and δ opioid receptor agonists would similarly result in synergy requiring PKCε. Combinations of μ and δ opioid receptor agonists were co-administered intrathecally by direct lumbar puncture to PKCε-wild-type (PKCε-WT) and -knockout (PKCε-KO) mice. Antinociception was assessed using the hot-water tail-flick assay. Drug interactions were evaluated by isobolographic analysis. All agonists produced comparable antinociception in both PKCε-WT and PKCε-KO mice. Of 19 agonist combinations that produced analgesic synergy, only 3 required PKCε for a synergistic interaction. In these three combinations, one of the agonists was morphine, although not all combinations involving morphine required PKCε. Morphine + deltorphin II and morphine + deltorphin I required PKCε for synergy, whereas a similar combination, morphine + deltorphin, did not. Additionally, morphine + oxymorphindole required PKCε for synergy, whereas a similar combination, morphine + oxycodindole, did not. We discovered biased agonism for a specific signalling pathway at the level of spinally co-delivered opioid agonists. As the bias is only revealed by an appropriate ligand combination and cannot be accounted for by a single drug, it is likely that the receptors these agonists act on are interacting with each other. Our results support the existence of μ and δ opioid receptor heteromers at the spinal level in vivo. This article is part of a themed section on Opioids: New Pathways to Functional Selectivity. To view the other articles in this section visit http://dx.doi.org/10.1111/bph.2015.172.issue-2. © 2014 The British Pharmacological Society.

  8. Efficacy of hemostasis for epidural venous plexus and safety for neural structure using soft coagulation system in spinal surgery: a laboratory investigation using a porcine model.

    PubMed

    Nishida, Kotaro; Kakutani, Kenichiro; Maeno, Koichiro; Takada, Toru; Yurube, Takashi; Kuroda, Ryosuke; Kurosaka, Masahiro

    2013-10-01

    A laboratory investigation using porcine model. To clarify the effectiveness of the soft coagulation system for stopping bleeding from the epidural vein using different outputs and the safety in terms of tissue damage including spinal cord injury. Problems associated with coagulation using an electrosurgical device, such as carbonization of tissue or adhesion to the electrode, have been highlighted. So called "soft coagulation" has been developed to solve these problems. Its' utility as well as the safety of the neural structure in spine surgery has never been reported. A total of 3 animals and 45 spinal segments were used. Total laminectomy was performed to expose the dural tube and epidural venous plexus. Stable bleeding was induced by a 22 G needle puncture. Soft coagulation monopolar output (SCM), soft coagulation bipolar output (SCB), and conventional bipolar output (CB) were used as the coagulators. Valid hemostasis was defined as macroscopically complete bleeding stoppage by coagulation within 3 minutes. The neurological assessment was evaluated by somatosensory evoked potential. Histologic analysis was performed to determine the area of thermal damage. Valid hemostasis ratio was 75.0% of SCM group, 68.8% of SCB group, and 30.8% of CB group. Somatosensory evoked potential monitoring revealed that spinal cord injury was observed in 4 lesions (25%) of the SCM group. Neither bipolar groups (SCB and CB) showed any changes in waveform pattern. Histologic analysis revealed that severe thermal damages were observed in the epidural space of the SCM group. The usefulness of soft coagulation is revealed in terms of bleeding stoppage from epidural vessels and reduced soft-tissue damage compared with the conventional electric device. However, assessing the potential risk of severe neural tissue damage including spinal cord injury, a bipolar soft coagulation is strongly recommended for use in spine surgery.

  9. Randomized and controlled prospective trials of Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia.

    PubMed

    Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z

    2015-01-01

    To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.

  10. Role of cranial and spinal virtual and augmented reality simulation using immersive touch modules in neurosurgical training.

    PubMed

    Alaraj, Ali; Charbel, Fady T; Birk, Daniel; Tobin, Matthew; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben

    2013-01-01

    Recent studies have shown that mental script-based rehearsal and simulation-based training improve the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, as a result of the reduction of work hours and current trends focusing on patient safety and linking reimbursement with clinical outcomes. Thus, there is a need for adjunctive means for neurosurgical training, which is a recent advancement in simulation technology. ImmersiveTouch is an augmented reality system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform uses multiple sensory modalities, re-creating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, and simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with the development of such augmented reality neurosurgical modules and the feedback from neurosurgical residents.

  11. Role of Cranial and Spinal Virtual and Augmented Reality Simulation Using Immersive Touch Modules in Neurosurgical Training

    PubMed Central

    Alaraj, Ali; Charbel, Fady T.; Birk, Daniel; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P.; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben

    2013-01-01

    Recent studies have shown that mental script-based rehearsal and simulation-based training improves the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, with reduction of working hours and current trends to focus on patient’s safety and linking reimbursement with clinical outcomes, and there is a need for adjunctive means for neurosurgical training;this has been recent advancement in simulation technology. ImmersiveTouch (IT) is an augmented reality (AR) system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform utilizes multiple sensory modalities, recreating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, in addition to simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with development of such AR neurosurgical modules and the feedback from neurosurgical residents. PMID:23254799

  12. Neonatal Meningoventriculitis Due to Proteus Mirabilis – A Case Report

    PubMed Central

    Juyal, Deepak; Rathaur, Vyas Kumar; Sharma, Neelam

    2013-01-01

    A five day old full term born baby was admitted to our Neonatal Intensive Care Unit with seizures, opisthotonous posture and was icteric upto thigh. Baby had a three day history of poor feeding, lethargy and abnormal body movements. Mother was a 29 years old primigravida and had a normal vaginal delivery at home. Sepsis profile of the patient was requested, lumbar puncture and ventricular tap was performed. Patient was put on third generation cephalosporins, aminoglycosides and phenobarbitone. Culture and sensitivity report of blood, Cerebro spinal fluid and ventricular fluid showed Proteus mirabilis. Computerized Tomography scan showed a large parenchymal lesion in the right frontal lobe and diffuse ependymal enhancement along both the lateral ventricles suggestive of meningoventriculitis. We hereby present a fatal case of neonatal meningoventriculitis due to Proteus mirabilis. PMID:23543669

  13. Port closure techniques.

    PubMed

    Shaher, Z

    2007-08-01

    Laparoscopic trocars do create wounds. This article aims to review and list different techniques used for closure of the fascia incision at trocar sites. A literature search was performed for articles dealing with closure techniques. The author searched this subject in English on Medline by combining the words "trocar" and "hernia," as well as "Deschamps" and "Reverdin." All articles reporting techniques with their references were reviewed. The articles described many techniques in addition to classical closure using curved needles, including Grice needle, Maciol needles, Endoclose device, Carter-Thomason device, Tahoe ligature device, Endo-Judge device, eXit puncture closure device, Lowsley retractor, spinal cord needles, dual hemostat, suture carrier, Riverdin and Deschamps needles, and Gore-Tex closure device. Three main groups of techniques were found with favor of extracorporeal manipulations under direct visualization. Old methods are sufficient and cost-effective.

  14. Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos

    Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histologicalmore » analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.« less

  15. Cutting performance orthogonal test of single plane puncture biopsy needle based on puncture force

    NASA Astrophysics Data System (ADS)

    Xu, Yingqiang; Zhang, Qinhe; Liu, Guowei

    2017-04-01

    Needle biopsy is a method to extract the cells from the patient's body with a needle for tissue pathological examination. Many factors affect the cutting process of soft tissue, including the geometry of the biopsy needle, the mechanical properties of the soft tissue, the parameters of the puncture process and the interaction between them. This paper conducted orthogonal experiment of main cutting parameters based on single plane puncture biopsy needle, and obtained the cutting force curve of single plane puncture biopsy needle by studying the influence of the inclination angle, diameter and velocity of the single plane puncture biopsy needle on the puncture force of the biopsy needle. Stage analysis of the cutting process of biopsy needle puncture was made to determine the main influencing factors of puncture force during the cutting process, which provides a certain theoretical support for the design of new type of puncture biopsy needle and the operation of puncture biopsy.

  16. Using a Motion Sensor-Equipped Smartphone to Facilitate CT-Guided Puncture.

    PubMed

    Hirata, Masaaki; Watanabe, Ryouhei; Koyano, Yasuhiro; Sugata, Shigenori; Takeda, Yukie; Nakamura, Seiji; Akamune, Akihisa; Tsuda, Takaharu; Mochizuki, Teruhito

    2017-04-01

    To demonstrate the use of "Smart Puncture," a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application. A puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone's liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guideline while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured. The mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased. This application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.

  17. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; McQueen, Miles A.

    1996-01-01

    A portable barrier strip having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests stable in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use.

  18. Retractable barrier strip

    DOEpatents

    Marts, D.J.; Barker, S.G.; McQueen, M.A.

    1996-04-16

    A portable barrier strip is described having retractable tire-puncture means for puncturing a vehicle tire. The tire-puncture means, such as spikes, have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture means removably disposed in a shaft that is rotatably disposed in each barrier block. The shaft removably and pivotally interconnects the plurality of barrier blocks. Actuation cables cause the shaft to rotate the tire-puncture means to the armed position for puncturing a vehicle tire and to the retracted position for not puncturing the tire. Each tire-puncture means is received in a hollow-bed portion of its respective barrier block when in the retracted position. The barrier strip rests in its deployed position and substantially motionless as a tire rolls thereon and over. The strip is rolled up for retrieval, portability, and storage purposes, and extended and unrolled in its deployed position for use. 13 figs.

  19. Postmyelography headache rates with Whitacre versus Quincke 22-gauge spinal needles.

    PubMed

    Peterman, S B

    1996-09-01

    To compare the postdural puncture headache (PDPH) rates after myelography with use of 22-gauge Whitacre (blunt tip) versus standard 22-gauge Quincke (bevel-tip) spinal needles. At myelography, 340 patients were randomly assigned to one of two groups in which either the Whitacre (167 patients) or the Quincke (173 patients) needle was used. Follow-up was at 48 hours and at 4 days after the procedure. Crude and adjusted Whitacre/PDPH odds ratios and risk ratios were calculated. The crude Whitacre needle PDPH risk was 9.6%, and the crude Quincke needle PDPH risk was 15.6%. The absolute risk difference was 6.0% with a 95% confidence interval of -0.98% and 13.04%. The adjusted Whitacre/PDPH odds ratio was 0.492 with a 95% confidence interval of 0.241 and 1.003. The Whitacre needle group had a statistically significantly lower PDPH severity grade (P = .0151), similar PDPH duration, and more technical difficulty with the needle. The Whitacre needle is associated with an equal or lower PDPH risk; the lack of statistical significance is most likely related to sample size. Further study is necessary to determine whether the decreased PDPH rate justifies the added difficulty associated with use of the Whitacre needle.

  20. Validation of a novel cost effective easy to produce and durable in vitro model for kidney-puncture and PNL-Simulation.

    PubMed

    Klein, Jan Thorsten; Rassweiler, Jens; Rassweiler-Seyfried, Marie-Claire Charlotte

    2018-03-29

    Nephrolithiasis is one of the most common diseases in urology. According to the EAU Guidelines, a percutaneous nephrolitholapaxy (PNL) is recommended when treating a kidney stone >2 cm. Nowadays PNL is performed even for smaller stones (<1 cm) using miniaturized instruments. The most challenging part of any PNL is the puncture of the planned site. PNL-novice surgeons need to practice this step in a safe environment with an ideal training model. We developed and evaluated a new, easy to produce, in-vitro model for the training of the freehand puncture of the kidney. Porcine kidneys with ureters were embedded in ballistic gel. Food coloring and preservative agent were added. We used the standard imaging modalities of X-ray and ultrasound to validate the training model. An additional new technique, the iPAD guided puncture, was evaluated. Five novices and three experts conducted 12 punctures for each imaging technique. Puncture time, radiation dose, and number of attempts to a successful puncture were measured. Mann-Whitney-U, Kruskal-Wallis, and U-Tests were used for statistical analyses. The sonographic guided puncture is slightly but not significantly faster than the fluoroscopic guided puncture and the iPAD assisted puncture. Similarly, the most experienced surgeon's time for a successful puncture was slightly less than that of the residents, and the experienced surgeons needed the least attempts to perform a successful puncture. In terms of radiation exposure, the residents had a significant reduction of radiation exposure compared to the experienced surgeons. The newly developed ballistic gel kidney-puncture model is a good training tool for a variety of kidney puncture techniques, with good content, construct, and face validity.

  1. Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.

    PubMed

    Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata

    2017-01-01

    A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirata, Masaaki, E-mail: masaaki314@gmail.com; Watanabe, Ryouhei; Koyano, Yasuhiro

    PurposeTo demonstrate the use of “Smart Puncture,” a smartphone application to assist conventional CT-guided puncture without CT fluoroscopy, and to describe the advantages of this application.Materials and MethodsA puncture guideline is displayed by entering the angle into the application. Regardless of the angle at which the device is being held, the motion sensor ensures that the guideline is displayed at the appropriate angle with respect to gravity. The angle of the smartphone’s liquid crystal display (LCD) is also detected, preventing needle deflection from the CT slice image. Physicians can perform the puncture procedure by advancing the needle using the guidelinemore » while the smartphone is placed adjacent to the patient. In an experimental puncture test using a sponge as a target, the target was punctured at 30°, 50°, and 70° when the device was tilted to 0°, 15°, 30°, and 45°, respectively. The punctured target was then imaged with a CT scan, and the puncture error was measured.ResultsThe mean puncture error in the plane parallel to the LCD was less than 2°, irrespective of device tilt. The mean puncture error in the sagittal plane was less than 3° with no device tilt. However, the mean puncture error tended to increase when the tilt was increased.ConclusionThis application can transform a smartphone into a valuable tool that is capable of objectively and accurately assisting CT-guided puncture procedures.« less

  3. The effect of skin entry site, needle angulation and soft tissue compression on simulated antegrade and retrograde femoral arterial punctures: an anatomical study using Cartesian co-ordinates derived from CT angiography.

    PubMed

    Tam, Matthew D B S; Lewis, Mark

    2012-10-01

    Safe femoral arterial access is an important procedural step in many interventional procedures and variations of the anatomy of the region are well known. The aim of this study was to redefine the anatomy relevant to the femoral arterial puncture and simulate the results of different puncture techniques. A total of 100 consecutive CT angiograms were used and regions of interest were labelled giving Cartesian co-ordinates which allowed determination of arterial puncture site relative to skin puncture site, the bifurcation and inguinal ligament (ING). The ING was lower than defined by bony landmarks by 16.6 mm. The femoral bifurcation was above the inferior aspect of the femoral head in 51% and entirely medial to the femoral head in 1%. Simulated antegrade and retrograde punctures with dogmatic technique, using a 45-degree angle would result in a significant rate of high and low arterial punctures. Simulated 50% soft tissue compression also resulted in decreased rate of high retrograde punctures but an increased rate of low antegrade punctures. Use of dogmatic access techniques is predicted to result in an unacceptably high rate of dangerous high and low punctures. Puncture angle and geometry can be severely affected by patient obesity. The combination of fluoroscopy to identify entry point, ultrasound-guidance to identify the femoral bifurcation and soft tissue compression to improve puncture geometry are critical for safe femoral arterial access.

  4. Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound

    PubMed Central

    Chan, Chen Jen; Srougi, Victor; Tanno, Fabio Yoshiaki; Jordão, Ricardo Duarte; Srougi, Miguel

    2015-01-01

    ABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device (“Punctiometer”). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure. PMID:26689521

  5. [Observation on therapeutic effect of electroacupuncture at Tianshu (ST 25) with deep needling technique on functional constipation].

    PubMed

    Wang, Cheng-Wei; He, Hong-Bo; Li, Ning; Wen, Qian; Liu, Zhi-Shun

    2010-09-01

    To probe into a better therapeutic method for functional constipation. Ninety-five cases of functional constipation were randomly divided into deep puncture at ST 25 group (48 cases), shallow puncture at ST 25 group (24 cases) and medication group (23 cases). In deep puncture at ST 25 group, Tianshu (ST 25) was punctured deeply to the peritoneum, with electric stimulation. In shallow puncture at ST 25 group, Tianshu (ST 25) was punctured shallowly, 5 mm beneath the skin, with electric stimulation. In medication group, Duphalac was administered orally. These cases were treated continuously for 4 weeks in 3 groups and followed up for 6 months. It was to observe the numbers of person who had defecation 4 times a week, difference in weekly defecation frequency and the difference in the Cleveland Clinic Score (CCS). In deep puncture at ST 25 group, the frequency of weekly defecation and the numbers of person who had defecation 4 times a week increased and CCS decreased, which were similar to the efficacy in shallow puncture at ST 25 group (all P > 0.05). But the efficacy of both ST 25 groups was superior to that in medication group (both P < 0.05). In comparison, the deep puncture at ST 25 group acted more quickly than either shallow puncture at ST 25 group or medication group and its efficacy remained much longer. The deep puncture at ST 25 with electric stimulation presents similar efficacy on functional constipation as shallow puncture at ST 25, but it acts more quickly than shallow puncture at ST 25, both of them are more advantageous than medication and the long-term efficacy is better.

  6. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate.

    PubMed

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-09-17

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system.

  7. Semi-analytical approach to estimate railroad tank car shell puncture

    DOT National Transportation Integrated Search

    2011-03-16

    This paper describes the development of engineering-based equations to estimate the puncture resistance of railroad tank cars under a generalized shell or side impact scenario. Resistance to puncture is considered in terms of puncture velocity, which...

  8. Retractable barrier strip

    DOEpatents

    Marts, Donna J.; Barker, Stacey G.; Wowczuk, Andrew; Vellenoweth, Thomas E.

    2002-01-01

    A portable barrier strip having retractable tire-puncture spikes for puncturing a vehicle tire. The tire-puncture spikes have an armed position for puncturing a tire and a retracted position for not puncturing a tire. The strip comprises a plurality of barrier blocks having the tire-puncture spikes removably disposed in a shaft that is rotatably disposed in each barrier block. The plurality of barrier blocks hare hingedly interconnected by complementary hinges integrally formed into the side of each barrier block which allow the strip to be rolled for easy storage and retrieval, but which prevent irregular or back bending of the strip. The shafts of adjacent barrier blocks are pivotally interconnected via a double hinged universal joint to accommodate irregularities in a roadway surface and to transmit torsional motion of the shaft from block to block. A single flexshaft cable is connected to the shaft of an end block to allow a user to selectively cause the shafts of a plurality of adjacently connected barrier blocks to rotate the tire-puncture spikes to the armed position for puncturing a vehicle tire, and to the retracted position for not puncturing the tire. The flexshaft is provided with a resiliently biased retracting mechanism, and a release latch for allowing the spikes to be quickly retracted after the intended vehicle tire is punctured.

  9. The Tension and Puncture Properties of HDPE Geomembrane under the Corrosion of Leachate

    PubMed Central

    Xue, Qiang; Zhang, Qian; Li, Zhen-Ze; Xiao, Kai

    2013-01-01

    To investigate the gradual failure of high-density polyethylene (HDPE) geomembrane as a result of long-term corrosion, four dynamic corrosion tests were conducted at different temperatures and durations. By combining tension and puncture tests, we systematically studied the variation law of tension and puncture properties of the HDPE geomembrane under different corrosion conditions. Results showed that tension and puncture failure of the HDPE geomembrane was progressive, and tensile strength in the longitudinal grain direction was evidently better than that in the transverse direction. Punctures appeared shortly after puncture force reached the puncture strength. The tensile strength of geomembrane was in inversely proportional to the corrosion time, and the impact of corrosion was more obvious in the longitudinal direction than transverse direction. As corrosion time increased, puncture strength decreased and corresponding deformation increased. As with corrosion time, the increase of corrosion temperature induced the decrease of geomembrane tensile strength. Tensile and puncture strength were extremely sensitive to temperature. Overall, residual strength had a negative correlation with corrosion time or temperature. Elongation variation increased initially and then decreased with the increase in temperature. However, it did not show significant law with corrosion time. The reduction in puncture strength and the increase in puncture deformation had positive correlations with corrosion time or temperature. The geomembrane softened under corrosion condition. The conclusion may be applicable to the proper designing of the HDPE geomembrane in landfill barrier system. PMID:28788321

  10. Isocentric Navigation of Percutaneous Endoscopic Transforaminal Discectomy at the L5/S1 Level in Difficult Puncture Cases: A Technical Note.

    PubMed

    Fan, Guoxin; Wang, Teng; Hu, Shuo; Guan, Xiaofei; Gu, Xin; He, Shisheng

    2017-05-01

    Accurate puncture during percutaneous transforaminal endoscopic discectomy at the L5/S1 level in cases with high iliac crest and narrow foramen were difficult, even though the difficulties of foraminoplasty could be overcome by advanced instruments like reamers. The report aimed to describe an isocentric navigation technique with a definite pathway in difficult puncture cases at the L5/S1 level. Technical note. Difficult punctures were defined as over 10 punctures of the needle before obtaining an ideal puncture location by senior surgeons with experience of over 500 percutaneous endoscopic transforaminal discectomy (PETD) cases. A total of 124 punctures were recorded in 11 difficult puncture cases at the L5/S1 level. A definite pathway was created by an isocentric navigation theory, which was based on a surface locator and an arch-guided device. The surface locator was used to rapidly and accurately identify the puncture target with the recognition of the surrounding rods under fluoroscopy. The arch-guided device can ensure that the puncture target always remains at the center of a virtual sphere. We recorded the puncture times, fluoroscopy exposure times, radiation exposure time, operative time, visual analog scale (VAS) score, Japanese Orthopeadic Association (JOA) score, and patient satisfaction. The average puncture times were significantly reduced to 1.27 with the arch-guided device compared with conventional puncture methods (P < 0.05). The average operative time was 90.09 ± 11.00 minutes and the fluoroscopy times were 53.36 ± 5.85. The radiation exposure time was 50.91 ± 5.20 seconds. VAS score of leg and back pain, as well as JOA score, were all significantly improved after surgery (P < 0.05). The excellent and good rate of satisfaction was 90.91%. No major complications, including cerebral fluid leakage, surgical infection, and postoperative nerve root injury, were recorded in this small sample. This was a small-sample study with a short follow-up. The novel isocentric navigation technique with a definite pathway is practical and effective in reducing puncture times among difficult puncture cases at the L5/S1 level, which may contribute to the capacity of PETD at the L5/S1 level.

  11. Evaluation of semi-empirical analyses for tank car puncture velocity, part II : correlations with engineering analyses

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the second in a series focusing on methods to determine the puncture velocity of railroad tank car shells. In this context, puncture velocity refers to the impact velocity at which a coupler will completely pierce the shell and punctur...

  12. Electron Microscopic Study of Demyelination in an Experimentally Induced Lesion in Adult Cat Spinal Cord

    PubMed Central

    Bunge, Richard P.; Bunge, Mary Bartlett; Ris, Hans

    1960-01-01

    Plaques of subpial demyelination were induced in adult cat spinal cords by repeated withdrawal and reinjection of cerebrospinal fluid. Peripheral cord was fixed by replacing cerebrospinal fluid available at cisternal puncture with 3 per cent buffered OsO4. Following extirpation, surface tissue was further fixed in 2 per cent buffered OsO4, dehydrated in ethanol, and embedded in araldite. Normal subpial cord consists mainly of myelinated axons and two types of macroglia, fibrous astrocytes and oligodendrocytes. Twenty-nine hours after lesion induction most myelin sheaths are deteriorating and typical macroglia are no longer visible. Phagocytosis of myelin debris has begun. In 3-day lesions, axons are intact and their mitochondria and neurofibrils appear normal despite continued myelin breakdown. All axons are completely demyelinated by 6 days. They lack investments only briefly, however, for at 10 and 14 days, macroglial processes appear and embrace them. These macroglia do not resemble either one of the normally occurring glia; their dense cytoplasm contains fibrils in addition to the usual organelles. It is proposed that these macroglia, which later accomplish remyelination, are the hypertrophic or swollen astrocytes of classical neuropathology. The suggestion that these astrocytes possess the potential to remyelinate axons in addition to their known ability to form cicatrix raises the possibility of pharmacological control of their expression. PMID:13805917

  13. Evaluation of semi-empirical analyses for railroad tank car puncture velocity, part 1 : correlations with experimental data

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the first in a two-part series that focuses on methodologies to determine the puncture velocity of tank car shells. In this context, puncture velocity refers to the impact velocity at which a coupler will puncture the tank. In this rep...

  14. MRimaging findings after ventricular puncture in patients with SAH.

    PubMed

    Tominaga, J; Shimoda, M; Oda, S; Kumasaka, A; Yamazaki, K; Tsugane, R

    2001-11-01

    Using magnetic resonance (MR) imaging, we studied brain injury from ventricular puncture performed during craniotomy in the acute stage of subarachnoid hemorrhage (SAH). 80 patients underwent craniotomy for aneurysm obliteration within 48 hr after SAH, ventricular puncture for drainage of cerebrospinal fluid (CSF) was performed to reduce intracranial pressure. MR imaging was performed within 3 days following surgery to measure the size of the lesion, and was repeated on postoperative days 14 and 30. Of the 80 patients with ventricular puncture preceding craniotomy, 65 (81%) showed MR evidence of brain injury from the puncture. Overall, 149 lesions were detected. According to coronal images, cortical injuries (54 cases), penetrating injury to tracts along the ventricular tube (55 cases), caudate injury (25 cases), and corpus callosum injury (15 cases). Brain injuries from ventricular puncture did not correlate significantly to patient outcome. While ventricular puncture and drainage of CSF can readily be performed to decrease brain volume at the time of craniotomy in acute-stage SAH, neurosurgeons should be aware of a surprisingly high incidence of brain injury complicating puncture.

  15. Preliminary clinical trial in percutaneous nephrolithotomy using a real-time navigation system for percutaneous kidney access

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Moreira, António H. J.; Rodrigues, Nuno F.; Pinho, A. C. M.; Fonseca, Jaime C.; Lima, Estevão.; Vilaça, João. L.

    2014-03-01

    Background: Precise needle puncture of renal calyces is a challenging and essential step for successful percutaneous nephrolithotomy. This work tests and evaluates, through a clinical trial, a real-time navigation system to plan and guide percutaneous kidney puncture. Methods: A novel system, entitled i3DPuncture, was developed to aid surgeons in establishing the desired puncture site and the best virtual puncture trajectory, by gathering and processing data from a tracked needle with optical passive markers. In order to navigate and superimpose the needle to a preoperative volume, the patient, 3D image data and tracker system were previously registered intraoperatively using seven points that were strategically chosen based on rigid bone structures and nearby kidney area. In addition, relevant anatomical structures for surgical navigation were automatically segmented using a multi-organ segmentation algorithm that clusters volumes based on statistical properties and minimum description length criterion. For each cluster, a rendering transfer function enhanced the visualization of different organs and surrounding tissues. Results: One puncture attempt was sufficient to achieve a successful kidney puncture. The puncture took 265 seconds, and 32 seconds were necessary to plan the puncture trajectory. The virtual puncture path was followed correctively until the needle tip reached the desired kidney calyceal. Conclusions: This new solution provided spatial information regarding the needle inside the body and the possibility to visualize surrounding organs. It may offer a promising and innovative solution for percutaneous punctures.

  16. Skin Punctures in Preterm Infants in the First 2 Weeks of Life.

    PubMed

    Finn, Daragh; Butler, Daryl; Sheehan, Orla; Livingstone, Vicki; Dempsey, Eugene M

    2018-05-23

     The objective of this study was to investigate frequency and trends of skin punctures in preterm infants.  A prospective audit of preterm infants less than 35 weeks admitted over a 6-month period to a tertiary neonatal intensive care unit. Each skin puncture performed in the first 2 weeks of life was documented in a specifically designed audit sheet.  Ninety-nine preterm infants were enrolled. Infants born at < 32 weeks' gestation had significantly more skin punctures than infants > 32 weeks (median skin punctures 26.5 vs. 17, p -value < 0.05). The highest frequency of skin punctures occurred during the first week of life for infants > 28 weeks' gestation (medians 17.5 in 28-31 + 6 weeks' gestation, and 15 in > 32 weeks), and during the second week of life for those born at < 28 weeks (median 17.5). Infants with sepsis had more skin punctures ( p -value < 0.001), but this was not significant on multivariate analysis. Median skin punctures in the second week of life were statistically higher in the sepsis group on multivariate analysis (odds ratio: 1.07, 95% confidence interval: 1.00-1.14, p  = 0.041).  Frequency of skin punctures is influenced by gestational age and postnatal age. Skin punctures were not an independent risk factor for sepsis. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  17. [Diagnostic accuracy research of needle puncture biopsy during operation for pulmonary single nodules].

    PubMed

    Chen, Jin-feng; Liu, Yi-nan; Wu, Nan; Feng, Yuan; Wang, Jia; Lü, Chao; Wang, Yu-zhao; Pei, Yu-quan; Yan, Shi; Zheng, Qing-feng; Zhang, Li-jian; Yang, Yue

    2012-04-01

    To investigate the diagnostic accuracy of needle puncture biopsy and pathological examination of frozen during operation for pulmonary nodules, and whether this diagnostic method can replace tumor resection examination. Totally 50 patients (28 males and 22 females, average age was 59 years) who had the single nodule after imaging examination without any pathological diagnostic from January to October 2010 were selected in this research work. During open operation or video assisted thoracic surgery, needle (14 G model) was used to puncture biopsy for pathological examination of frozen. All the adverse events during puncture biopsy would be recorded. The resection specimens would be accepted paraffin pathological examination. The relationship between puncture frozen pathological and paraffin pathological examination was analyzed. All tumor sizes were ranged from 1.0 cm × 0.6 cm to 5.6 cm × 9.0 cm. The paraffin pathological examination after operation as the golden standard, there were 7 cases of benign tumor and 43 cases of malignant tumor. The diagnostic sensitivity of puncture biopsy was 90.7%, the specificity was 100%, the positive predictive value was 100% and the negative predictive value was 63.6%. There were 11 cases of benign tumor diagnosed by needle puncture biopsy, among which 4 cases were proved as malignant tumor by paraffin pathology, and the false negative rate was 9.3%. The main risk of puncture biopsy was bleeding after puncture immediately, and the rate was 4.0% (2/50). The puncture biopsy during operation had a high specificity for malignant lung tumor, and there was a certain false negative rate for benign tumor. Puncture biopsy and pathological examination of frozen tissue can replace tumor section biopsy in a way.

  18. Medical information on the Internet: Quality assessment of lumbar puncture and neuroaxial block techniques on YouTube.

    PubMed

    Rössler, Bernhard; Lahner, Daniel; Schebesta, Karl; Chiari, Astrid; Plöchl, Walter

    2012-07-01

    The Internet has become the largest, most up-to-date source for medical information. Besides enhancing patients' knowledge, the freely accessible audio-visual files have an impact on medical education. However little is known about their characteristics. In this manuscript the quality of lumbar puncture (LP) and spinal anaesthesia (SA) videos available on YouTube is assessed. This retrospective analysis was based on a search for LP and SA on YouTube. Videos were evaluated using essential key points (5 in SA, 4 in LP) and 3 safety indicators. Furthermore, violation of sterile working techniques and a rating whether the video must be regarded as dangerously misleading was performed. From 2321 hits matching the keywords, 38 videos were eligible for evaluation. In LP videos, 14% contained information on all, 4.5% on 3 and 4.5% on 2 key points, 59% on 1 and 18% on no key point. Regarding SA, no video contained information on all 5 key points, 56% on 2-4 and 25% on 1 key point, 19% did not contain any essential information. A sterility violation occurred in 11%, and 13% were classified as dangerously misleading. Even though high quality videos are available, the quality of video clips is generally low. The fraction of videos that were not performed in an aseptic manner is low, but these pose a substantial risk to patients. Consequently, more high-quality, institutional medical learning videos must be made available in the light of the increased utilization on the Internet. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Transfer of simulated lumbar puncture training to the clinical setting.

    PubMed

    White, Marjorie L; Jones, Rachel; Zinkan, Lynn; Tofil, Nancy M

    2012-10-01

    To show that with a combination of evidence-based didactic and hands-on skill demonstration, pediatric interns will be able to correctly perform lumbar punctures (LPs) on neonates in the actual clinical setting. Twenty-three pediatric and internal medicine/pediatric first year residents attended a 1-hour course during their orientation. The course consisted of an evidence-based presentation, reviewing anatomy, indications, complications, and techniques for performing LPs, including a video presentation, followed by hands-on practice of LPs. All interns were anonymously surveyed preintervention and postintervention. The survey results were compared for each learner. After the intervention, interns were individually assessed by a single investigator using a standardized checklist during an LP of an actual pediatric patient during their first year of residency. Pretest and posttest knowledge improved by approximately 12% (P < 0.05). Preintervention confidence and experience were low among learners. Twenty-one of 23 interns completed a follow-up assessment of an LP on an actual pediatric patient. The average on the assessment was 9.7 ± 1.1 of 11 (88% ± 10%). The average number of LP attempts was 1.4 ± 0.5. The steps most frequently missed were preparing the supplies and performing the LP with the bevel of the needle parallel to the spinal ligament, with only 48% of interns performing each of these steps correctly. A task trainer-based course improved the confidence and knowledge about an important pediatric procedure. This confidence and knowledge can translate to actual clinical practice. Further investigations are necessary to support this knowledge and skill translation.

  20. Continuous thermographic observation may predict extravasation in chemotherapy-treated patients.

    PubMed

    Oya, Maiko; Murayama, Ryoko; Oe, Makoto; Yabunaka, Koichi; Tanabe, Hidenori; Takahashi, Toshiaki; Matsui, Yuko; Otomo, Eiko; Komiyama, Chieko; Sanada, Hiromi

    2017-06-01

    Extravasation, or leakage of vesicant drugs into subcutaneous tissues, causes serious complications such as induration and necrosis in chemotherapy-treated patients. As macroscopic observation may overlook symptoms during infusion, we focused on skin temperature changes at puncture sites and studied thermographic patterns related to induration or necrosis caused by extravasation. Outpatients undergoing chemotherapy using peripheral intravenous catheters were enrolled in this prospective observational study. We filmed and classified infrared thermography movies of puncture sites during infusion; ultrasonography was also utilized at puncture sites to observe the subcutaneous condition. Multiple logistic regression analysis was performed to examine the association of thermographic patterns with induration or necrosis observed on the next chemotherapy day. Differences in patient characteristics, puncture sites, and infusions were analyzed by Mann-Whitney's U test and Fisher's exact test according to thermographic patterns. Eight patients developed induration among 74 observations in 62 patients. Among six thermographic patterns, a fan-shaped lower temperature area gradually spreading from the puncture site (fan at puncture site) was significantly associated with induration. Ultrasonography revealed that catheters of patients with fan at puncture site remained in the vein at the end of infusion, indicating that the infusion probably leaked from the puncture site. Patients with fan at puncture site had no significant differences in characteristics and infusion conditions compared with those with the other five thermographic patterns. We determined that fan at puncture site was related to induration caused by extravasation. Continuous thermographic observation may enable us to predict adverse events of chemotherapy. Copyright © 2017. Published by Elsevier Ltd.

  1. The training and learning process of transseptal puncture using a modified technique.

    PubMed

    Yao, Yan; Ding, Ligang; Chen, Wensheng; Guo, Jun; Bao, Jingru; Shi, Rui; Huang, Wen; Zhang, Shu; Wong, Tom

    2013-12-01

    As the transseptal (TS) puncture has become an integral part of many types of cardiac interventional procedures, its technique that was initial reported for measurement of left atrial pressure in 1950s, continue to evolve. Our laboratory adopted a modified technique which uses only coronary sinus catheter as the landmark to accomplishing TS punctures under fluoroscopy. The aim of this study is prospectively to evaluate the training and learning process for TS puncture guided by this modified technique. Guided by the training protocol, TS puncture was performed in 120 consecutive patients by three trainees without previous personal experience in TS catheterization and one experienced trainer as a controller. We analysed the following parameters: one puncture success rate, total procedure time, fluoroscopic time, and radiation dose. The learning curve was analysed using curve-fitting methodology. The first attempt at TS crossing was successful in 74 (82%), a second attempt was successful in 11 (12%), and 5 patients failed to puncture the interatrial septal finally. The average starting process time was 4.1 ± 0.8 min, and the estimated mean learning plateau was 1.2 ± 0.2 min. The estimated mean learning rate for process time was 25 ± 3 cases. Important aspects of learning curve can be estimated by fitting inverse curves for TS puncture. The study demonstrated that this technique was a simple, safe, economic, and effective approach for learning of TS puncture. Base on the statistical analysis, approximately 29 TS punctures will be needed for trainee to pass the steepest area of learning curve.

  2. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  3. Elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation.

    PubMed

    Li, Yan; Deng, Jianxin; Zhou, Jun; Li, Xueen

    2016-11-01

    Corresponding to pre-puncture and post-puncture insertion, elastic and viscoelastic mechanical properties of brain tissues on the implanting trajectory of sub-thalamic nucleus stimulation are investigated, respectively. Elastic mechanical properties in pre-puncture are investigated through pre-puncture needle insertion experiments using whole porcine brains. A linear polynomial and a second order polynomial are fitted to the average insertion force in pre-puncture. The Young's modulus in pre-puncture is calculated from the slope of the two fittings. Viscoelastic mechanical properties of brain tissues in post-puncture insertion are investigated through indentation stress relaxation tests for six interested regions along a planned trajectory. A linear viscoelastic model with a Prony series approximation is fitted to the average load trace of each region using Boltzmann hereditary integral. Shear relaxation moduli of each region are calculated using the parameters of the Prony series approximation. The results show that, in pre-puncture insertion, needle force almost increases linearly with needle displacement. Both fitting lines can perfectly fit the average insertion force. The Young's moduli calculated from the slope of the two fittings are worthy of trust to model linearly or nonlinearly instantaneous elastic responses of brain tissues, respectively. In post-puncture insertion, both region and time significantly affect the viscoelastic behaviors. Six tested regions can be classified into three categories in stiffness. Shear relaxation moduli decay dramatically in short time scales but equilibrium is never truly achieved. The regional and temporal viscoelastic mechanical properties in post-puncture insertion are valuable for guiding probe insertion into each region on the implanting trajectory.

  4. Emergency airway puncture

    MedlinePlus

    ... support for only a very short period of time. Alternative Names Needle cricothyrotomy Images Emergency airway puncture Cricoid cartilage Emergency airway puncture - series References Hebert RB, Bose S, Mace SE. Cricothyrotomy and ...

  5. Establishment of temporomandibular joint puncture technique in rats using in vivo micro-computed tomography (R_mCT®)

    PubMed Central

    Kameoka, S; Matsumoto, K; Kai, Y; Yonehara, Y; Arai, Y; Honda, K

    2010-01-01

    The aim of the report was to establish puncture techniques for the temporomandibular joint (TMJ) cavity in rats. The experimental sample comprised 30 male Sprague–Dawley rats. Under general anaesthesia the superior joint cavity of the rat was punctured either laterally (lateral puncture technique (LPT), n = 11), anteriorly (anterosuperior puncture technique (ASPT), n = 13) or anteroinferior puncture technique (AIPT), n = 6) using a 27-gauge needle. After the tip of the needle was confirmed by micro-CT (R-mCT®, Rigaku, Tokyo, Japan) located on the mandibular fossa, 0.05 ml of contrast media was injected under micro-CT fluoroscopic guidance. After confirmation that the joint cavity was filled with contrast media, micro-CT imaging was carried out. The puncture for LPT was accurate in 5 of the 11 animals. The ASPT was accurate in all 13 animals. The AIPT punctured 3 of the 6 animals. Furthermore, the ASPT and AIPT demonstrated improved preservation of the needle; it was harder to detach the needle, which led to greater stability. These results suggest that ASPT assisted by R-mCT® is useful for basic research, including drug discovery and pathogenesis of TMJ diseases. PMID:20841463

  6. Lumbar puncture opening pressure is not a reliable measure of intracranial pressure in children.

    PubMed

    Cartwright, Cathy; Igbaseimokumo, Usiakimi

    2015-02-01

    There is very little data correlating lumbar puncture pressures to formal intracranial pressure monitoring despite the widespread use of both procedures. The hypothesis was that lumbar puncture is a single-point measurement and hence it may not be a reliable evaluation of intracranial pressure. The study was therefore carried out to compare lumbar puncture opening pressures with the Camino bolt intracranial pressure monitor in children. Twelve children with a mean age of 8.5 years who had both lumbar puncture and intracranial pressure monitoring were analyzed. The mean lumbar puncture opening pressure was 22.4 mm Hg versus a mean Camino bolt intracranial pressure of 7.8 mm Hg (P < .0001). Lumbar puncture therefore significantly overestimates the intracranial pressure in children. There were no complications from the intracranial pressure monitoring, and the procedure changed the treatment of all 12 children avoiding invasive operative procedures in most of the patients. © The Author(s) 2014.

  7. Puncture Wounds

    MedlinePlus

    ... into the wound during a puncture, along with dirt and debris from the object. All puncture wounds ... object, such as a rusty nail, the more dirt and debris are dragged into the wound, increasing ...

  8. Comparison of blood chemistry values for samples collected from juvenile chinook salmon by three methods

    USGS Publications Warehouse

    Congleton, J.L.; LaVoie, W.J.

    2001-01-01

    Thirteen blood chemistry indices were compared for samples collected by three commonly used methods: caudal transection, heart puncture, and caudal vessel puncture. Apparent biases in blood chemistry values for samples obtained by caudal transection were consistent with dilution with tissue fluids: alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), creatine kinase (CK), triglyceride, and K+ were increased and Na+ and Cl- were decreased relative to values for samples obtained by caudal vessel puncture. Some enzyme activities (ALT, AST, LDH) and K+ concentrations were also greater in samples taken by heart puncture than in samples taken by caudal vessel puncture. Of the methods tested, caudal vessel puncture had the least effect on blood chemistry values and should be preferred for blood chemistry studies on juvenile salmonids.

  9. Management of pedal puncture wounds.

    PubMed

    Belin, Ronald; Carrington, Scott

    2012-07-01

    Puncture wounds of the foot are a common injury, and infection associated with these injuries may result in considerable morbidity. The pathophysiology and management of a puncture wound is dependent on the material that punctures the foot, the location and depth of the wound, time to presentation, footwear, and underlying health status of the patient. Puncture wounds should not be treated lightly, so accurate diagnosis, assessment, and treatment are paramount. Early incision and drainage, vaccination, and the use of proper antibiotics can lead to positive outcomes and prevent limb-threatening circumstances. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-carterial nitroglycerin in transradial procedures: a randomized trial.

    PubMed

    Turan, Burak; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-01-01

    Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Total of 101 participants (mean age 60±11years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36-75] vs 50 [35-90] sec), puncture attempts (1.18±0.48 vs 1.20±0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients <1.65m height (47 [36-66] vs 63 [41-110] sec, p=0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p=0.028) or in patients <1.65m height (7.4 vs 25%, p=0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p=0.089). SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wybranski, Christian, E-mail: Christian.Wybranski@uk-koeln.de; Pech, Maciej; Lux, Anke

    ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BDmore » and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.« less

  12. 78 FR 22213 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ... float assemblies for any cuts, tears, punctures, or abrasion. Replace the cover if the internal... cuts, tears, punctures, or abrasion. If there is a cut, tear, puncture, or any abrasion, repair the...

  13. Assessment of the SonixGPS system for its application in real-time ultrasonography navigation-guided percutaneous nephrolithotomy for the treatment of complex kidney stones.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; He, Hui

    2017-04-01

    SonixGPS is a novel real-time ultrasonography navigation technology, which has been demonstrated to promote accuracy of puncture in surgical operations. The aim of this study is to evaluate its application in guiding the puncture during percutaneous nephrolithotomy (PCNL). We retrospectively reviewed our experience in treating a total of 74 patients with complex kidney stones with PCNL, in which puncture in 37 cases were guided by SonixGPS system, while the other 37 by conventional ultrasound. The effectiveness of operation was evaluated in terms of stone clearance rate, operation time, time to successful puncture, number of attempts for successful puncture and hospital stay. The safety of operation was examined by evaluating postoperative complications. Our retrospective review showed that although there were no significant differences in stone clearance rates between the groups, SonixGPS guidance resulted in more puncture accuracy with shorter puncture time and higher successful puncture rate. Under the help of SonixGPS, most patients (92 %) had no or just mild complications, compared to that (73 %) in conventional ultrasound group. Post-operative decrease of hemoglobin in SonixGPS group was 13.79 (7-33) mg/dl, significantly lower than that 20.97 (8-41) mg/dl in conventional ultrasound group. Our experience demonstrates that SonixGPS is superior to conventional ultrasound in guiding the puncture in PCNL for the treatment of complex kidney stone.

  14. A method for the determination of syringe needle punctures in rubber stoppers using stereoscopic light microscopy.

    PubMed

    Platek, S Frank; Keisler, Mark A; Ranieri, Nicola; Reynolds, Todd W; Crowe, John B

    2002-09-01

    The ability to accurately determine the number of syringe needle penetration holes through the rubber stoppers in pharmaceutical vials and rubber septa in intravenous (i.v.) line and bag ports has been a critical factor in a number of forensic cases involving the thefts of controlled substances or suspected homicide by lethal injection. In the early 1990s, the microscopy and microanalysis group of the U.S. Food and Drug Administration's Forensic Chemistry Center (FCC) developed and implemented a method (unpublished) to locate needle punctures in rubber pharmaceutical vial stoppers. In 1996, as part of a multiple homicide investigation, the Indiana State Police Laboratory (ISPL) contacted the FCC for information on a method to identify and count syringe needle punctures through rubber stoppers in pharmaceutical vials. In a joint project and investigation using the FCC's needle hole location method and applying a method of puncture site mapping developed by the ISPL, a systematic method was developed to locate, identify, count, and map syringe punctures in rubber bottle stoppers or i.v. bag ports using microscopic analysis. The method requires documentation of punctures on both sides of the rubber stoppers and microscopic analysis of each suspect puncture site. The final result of an analysis using the method is a detailed diagram of puncture holes on both sides of a questioned stopper and a record of the minimum number of puncture holes through a stopper.

  15. Puncture mechanics of soft elastomeric membrane with large deformation by rigid cylindrical indenter

    NASA Astrophysics Data System (ADS)

    Liu, Junjie; Chen, Zhe; Liang, Xueya; Huang, Xiaoqiang; Mao, Guoyong; Hong, Wei; Yu, Honghui; Qu, Shaoxing

    2018-03-01

    Soft elastomeric membrane structures are widely used and commonly found in engineering and biological applications. Puncture is one of the primary failure modes of soft elastomeric membrane at large deformation when indented by rigid objects. In order to investigate the puncture failure mechanism of soft elastomeric membrane with large deformation, we study the deformation and puncture failure of silicone rubber membrane that results from the continuous axisymmetric indentation by cylindrical steel indenters experimentally and analytically. In the experiment, effects of indenter size and the friction between the indenter and the membrane on the deformation and puncture failure of the membrane are investigated. In the analytical study, a model within the framework of nonlinear field theory is developed to describe the large local deformation around the punctured area, as well as to predict the puncture failure of the membrane. The deformed membrane is divided into three parts and the friction contact between the membrane and indenter is modeled by Coulomb friction law. The first invariant of the right Cauchy-Green deformation tensor I1 is adopted to predict the puncture failure of the membrane. The experimental and analytical results agree well. This work provides a guideline in designing reliable soft devices featured with membrane structures, which are present in a wide variety of applications.

  16. Primary tracheoesophageal puncture and cricopharyngeal myotomy in stapler-assisted total laryngectomy.

    PubMed

    Beswick, D M; Damrose, E J

    2016-07-01

    To evaluate the utility of the hybrid tracheoesophageal puncture procedure in stapler-assisted laryngectomy. Patients who underwent total laryngectomy at a single institution from 2009 to 2015 were reviewed. The interventions assessed were surgical creation of a tracheoesophageal puncture and placement of a voice prosthesis. The outcomes measured included voicing ability and valve failure. Thirty-nine patients underwent total laryngectomy or pharyngolaryngectomy. Of these, nine underwent stapler-assisted laryngectomy; seven of the nine patients underwent concurrent stapler-assisted laryngectomy, cricopharyngeal myotomy and a hybrid tracheoesophageal puncture procedure. These seven patients were the focus of this review. Successful voicing and oral alimentation was achieved in all patients. Mean time to phonation was 30 days (range, 7-77 days) and mean time to first valve change was 90 days (range, 35-117 days). Primary tracheoesophageal puncture with concurrent voice prosthesis placement and cricopharyngeal myotomy is easily performed with stapler-assisted laryngectomy. The hybrid tracheoesophageal puncture procedure is a simple method that enables a single operator to achieve primary tracheoesophageal puncture and valve placement; in addition, it facilitates concurrent cricopharyngeal myotomy.

  17. Engineering analyses for railroad tank car head puncture resistance

    DOT National Transportation Integrated Search

    2006-11-06

    This paper describes engineering analyses to estimate the : forces, deformations, and puncture resistance of railroad tank : cars. Different approaches to examine puncture of the tank car : head are described. One approach is semi-empirical equations...

  18. A technique for ultrasound-guided blood sampling from a dry and gel-free puncture area.

    PubMed

    Thorn, Sofie; Gopalasingam, Nigopan; Bendtsen, Thomas Fichtner; Knudsen, Lars; Sloth, Erik

    2016-05-07

    Vein punctures are performed daily to sample blood. Ultrasound (US) offers an alternative to the blind landmark technique for difficult vascular access. A challenge for this procedure is the presence of US gel in the puncture area. We present a technique for US-guided puncture from extremity veins not palpable or visible to the human eye, while keeping the puncture area dry and gel-free. Ten healthy volunteers underwent two US-guided vein punctures from veins that were neither palpable nor visible. One was drawn from an antebrachial vein and another from a brachial vein. A sterile barrier drape was made from a commercially available dressing and a piece of transparent sterile plastic. The barrier drape consists of an adhesive part placed on the skin designed for sonography and a free transparent flap constituting the barrier between the unsterile sonographic site and the sterile gel-free puncture site. The success rate for vein puncture was 100% in both locations. A total of 22 skin punctures were performed (11 antebrachial and 11 brachial). Gain output was increased 7% (4-12%), and 8% (4-15%), respectively, to compensate for attenuation of the US signal due to the drape. Alignment of the centre of the transducer with the long-axis of the target vein during the procedure was reported as a challenge. US-guided blood sampling from a brachial and antebrachial vein was possible with a 100% success rate, while ensuring a dry and gel-free venipuncture area on one side and the transducer on the other side of a sterile barrier.

  19. Intrathecal bone marrow stromal cells inhibit neuropathic pain via TGF-β secretion

    PubMed Central

    Chen, Gang; Park, Chul-Kyu; Xie, Rou-Gang; Ji, Ru-Rong

    2015-01-01

    Neuropathic pain remains a pressing clinical problem. Here, we demonstrate that a local, intrathecal (i.t.) injection of bone marrow stromal cells (BMSCs) following lumbar puncture alleviates early- and late-phase neuropathic pain symptoms, such as allodynia and hyperalgesia, for several weeks in murine chronic constriction injury (CCI) and spared nerve injury models. Moreover, i.t. BMSCs reduced CCI-induced spontaneous pain and axonal injury of dorsal root ganglion (DRG) neurons and inhibited CCI-evoked neuroinflammation in DRGs and spinal cord tissues. BMSCs secreted TGF-β1 into the cerebrospinal fluid, and neutralization of TGF-β1, but not IL-10, reversed the analgesic effect of BMSCs. Conversely, i.t. administration of TGF-β1 potently inhibited neuropathic pain. TGF-β1 acted as a powerful neuromodulator and rapidly (within minutes) suppressed CCI-evoked spinal synaptic plasticity and DRG neuronal hyperexcitability via TGF-β receptor 1–mediated noncanonical signaling. Finally, nerve injury upregulated CXCL12 in lumbar L4–L6 DRGs, and this upregulation caused migration of i.t.-injected BMSCs to DRGs through the CXCL12 receptor CXCR4, which was expressed on BMSCs. BMSCs that migrated from the injection site survived at the border of DRGs for more than 2 months. Our findings support a paracrine mechanism by which i.t. BMSCs target CXCL12-producing DRGs to elicit neuroprotection and sustained neuropathic pain relief via TGF-β1 secretion. PMID:26168219

  20. Point of impact: the effect of size and speed on puncture mechanics.

    PubMed

    Anderson, P S L; LaCosse, J; Pankow, M

    2016-06-06

    The use of high-speed puncture mechanics for prey capture has been documented across a wide range of organisms, including vertebrates, arthropods, molluscs and cnidarians. These examples span four phyla and seven orders of magnitude difference in size. The commonality of these puncture systems offers an opportunity to explore how organisms at different scales and with different materials, morphologies and kinematics perform the same basic function. However, there is currently no framework for combining kinematic performance with cutting mechanics in biological puncture systems. Our aim here is to establish this framework by examining the effects of size and velocity in a series of controlled ballistic puncture experiments. Arrows of identical shape but varying in mass and speed were shot into cubes of ballistic gelatine. Results from high-speed videography show that projectile velocity can alter how the target gel responds to cutting. Mixed models comparing kinematic variables and puncture patterns indicate that the kinetic energy of a projectile is a better predictor of penetration than either momentum or velocity. These results form a foundation for studying the effects of impact on biological puncture, opening the door for future work to explore the influence of morphology and material organization on high-speed cutting dynamics.

  1. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections

    PubMed Central

    Marker, David R.; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.; Carrino, John A.; Fritz, Jan

    2017-01-01

    PURPOSE The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. METHODS A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. RESULTS Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. CONCLUSION 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus. PMID:28420598

  2. 1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections.

    PubMed

    Marker, David R; U Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J; Fichtinger, Gabor; Iordachita, Iulian I; Carrino, John A; Fritz, Jan

    2017-01-01

    The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner. A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length. Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1-5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min. 1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus.

  3. Acute human herpes virus 7 (HHV-7) encephalitis in an immunocompetent adult patient: a case report and review of literature.

    PubMed

    Riva, Nicoletta; Franconi, Iacopo; Meschiari, Marianna; Franceschini, Erica; Puzzolante, Cinzia; Cuomo, Gianluca; Bianchi, Alessandro; Cavalleri, Francesca; Genovese, Maurilio; Mussini, Cristina

    2017-06-01

    We report a case of an acute HHV-7 encephalitis involving the nucleus of the VI cranial nerve in an immunocompetent host. The patient was an adult male admitted to our Clinic with headache, diplopia, fever, nausea, vertigo, asthenia and general malaise. PCR for viral and bacterial genomes was run on both serum and cerebral spinal fluid (CSF) after performing lumbar puncture, resulting positive only for HHV-7 DNA on CSF. MRI showed hyperintensity in FLAIR signal in the dorsal pons, in the area of the VI cranial nerve nucleus. Empirical therapy with Acyclovir and Dexamethasone was started at the time of admission and was continued after the microbiology results. After three days of therapy diplopia, fever and other previous clinical manifestations improved and the patient recovered normal sight. Our case report contributes to a better understanding of the presentation, diagnosis and treatment of HHV-7 encephalitis in immunocompetent patients due to reactivation in adult age.

  4. Preferred view and transducer in lumbar ultrasound in overweight and obese patients.

    PubMed

    Farahmand, Shervin; Safavi, Somayeh; Shahriarian, Shahriar; Arbab, Mona; Basirghafoori, Hamed; Bagheri-Hariri, Shahram

    2017-02-01

    Ultrasound can be used to facilitate lumbar puncture, especially in obese patients. In this study, midline and paramedian approaches with curved and linear transducers were compared in patients with Body Mass Index (BMI) above 25 kg/m 2 for the identification of spinal landmarks. In each view, six major landmarks, including spinous process, ligamentum flavum, laminae, epidural space, subarachnoid space and posterior longitudinal ligament, were detected by emergency medicine residents and were then reviewed by radiologists. Sixty patients with a mean BMI of 29.18 enrolled in the study. This study showed that a curved transducer detected major landmarks more accurately compared to a linear transducer. There was also a poor kappa correlation between these transducers in the midline and paramedian approaches. This study showed that ultrasound can detect lumbar landmarks in overweight and obese patients, with the paramedian approach and a curved transducer being superior to the midline approach and a linear transducer in detecting these landmarks.

  5. The Sonographic Appearance of Spinal Fluid at Clinically Selected Interspaces in Sitting Versus Lateral Positions.

    PubMed

    Vitberg, Yaffa M; Tseng, Peggy; Kessler, David O

    2018-05-01

    Our objective was to describe the sonographic appearance of fluid at clinically selected interspinous spaces and see if additional interspaces could be identified as suitable and safe targets for needle insertion. We also measured the reproducibility of fluid measurements and assessed for positional differences. A prospective convenience sample of infants younger than 3 months was enrolled in the pediatric emergency department. Excluded were clinically unstable infants or those with spinal dysraphism. Infants were first held in standard lateral lumbar puncture position. Pediatric emergency medicine (PEM) physicians marked infants' backs at the level they would insert a needle using the landmark palpation technique. A PEM sonologist imaged and measured the spinal fluid in 2 orthogonal planes at this marked level in lateral then sitting positions. Fluid measurements were repeated by a second blinded PEM sonologist. Forty-six infants were enrolled. Ultrasound verified the presence of fluid at the marked level as determined by the landmark palpation technique in 98% of cases. Ultrasound identified additional suitable spaces 1 space higher (82%) and 2 spaces higher (41%). Intraclass correlation coefficient of all measurements was excellent (>0.85), with differences noted for sitting versus lateral position in mean area of fluid 0.34 mm versus 0.31 mm (difference, 0.03; 95% confidence interval [CI], 0.005-0.068), dorsal fluid pocket 0.23 mm versus 0.15 mm (difference, 0.08; 95% CI, 0.031-0.123), and nerve root-to-canal ratio 0.44 versus 0.51 (difference, 0.07; 95% CI, 0.004-0.117). Ultrasound can verify the presence of fluid at interspaces determined by the landmark palpation technique and identify additional suitable spaces at higher levels. There were statistically greater fluid measurements in sitting versus lateral positions. These novel fluid measurements were shown to be reliable.

  6. Influence of Medial Collateral Ligament Release for Internal Rotation of Tibia in Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study.

    PubMed

    Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi

    2017-01-01

    Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Incidence and management of inadvertent puncture and sheath placement in the aorta during attempted transseptal puncture.

    PubMed

    Wasmer, Kristina; Zellerhoff, Stephan; Köbe, Julia; Mönnig, Gerold; Pott, Christian; Dechering, Dirk G; Lange, Philipp S; Frommeyer, Gerrit; Eckardt, Lars

    2017-03-01

    Transseptal punctures (TSP) are routinely performed in cardiac interventions requiring access to the left heart. While pericardial effusion/tamponade are well-recognized complications, few data exist on accidental puncture of the aorta and its management and outcome. We therefore analysed our single centre database for this complication. We assessed frequency and outcome of inadvertent aortic puncture during TSP in consecutive patients undergoing ablation procedures between January 2005 and December 2014. During the 10-year period, two inadvertent aortic punctures occurred among 2936 consecutive patients undergoing 4305 TSP (0.07% of patients, 0.05% of TSP) and in one Mustard patient during attempted baffle puncture. The first two patients required left ventricular access for catheter ablation of ventricular tachycardia. In both cases, an 11.5F steerable sheath (inner diameter 8.5F) was accidentally placed in the ascending aorta just above the aortic valve. In the presence of surgical standby, the sheaths were pulled back with a wire left in the aorta. Under careful haemodynamic and echocardiographic observation, this wire was also pulled back 30 min later. None of the patients required a closing device or open heart surgery. None of the patients suffered complications from the accidental aortic puncture and sheath placement. Inadvertent aortic puncture and sheath placement are rare complications in patients undergoing TSP for interventional procedures. Leaving a guidewire in place during the observation period may allow introduction of sheaths or other tools in order to control haemodynamic deterioration. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Liebl, Andrea; Poullos, Nektarios

    Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36more » h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.« less

  9. A New Navigation System of Renal Puncture for Endoscopic Combined Intrarenal Surgery: Real-time Virtual Sonography-guided Renal Access.

    PubMed

    Hamamoto, Shuzo; Unno, Rei; Taguchi, Kazumi; Ando, Ryosuke; Hamakawa, Takashi; Naiki, Taku; Okada, Shinsuke; Inoue, Takaaki; Okada, Atsushi; Kohri, Kenjiro; Yasui, Takahiro

    2017-11-01

    To evaluate the clinical utility of a new navigation technique for percutaneous renal puncture using real-time virtual sonography (RVS) during endoscopic combined intrarenal surgery. Thirty consecutive patients who underwent endoscopic combined intrarenal surgery for renal calculi, between April 2014 and July 2015, were divided into the RVS-guided puncture (RVS; n = 15) group and the ultrasonography-guided puncture (US; n = 15) group. In the RVS group, renal puncture was repeated until precise piercing of a papilla was achieved under direct endoscopic vision, using the RVS system to synchronize the real-time US image with the preoperative computed tomography image. In the US group, renal puncture was performed under US guidance only. In both groups, 2 urologists worked simultaneously to fragment the renal calculi after inserting the miniature percutaneous tract. The mean sizes of the renal calculi in the RVS and the US group were 33.5 and 30.5 mm, respectively. A lower mean number of puncture attempts until renal access through the calyx was needed for the RVS compared with the US group (1.6 vs 3.4 times, respectively; P = .001). The RVS group had a lower mean postoperative hemoglobin decrease (0.93 vs 1.39 g/dL, respectively; P = .04), but with no between-group differences with regard to operative time, tubeless rate, and stone-free rate. None of the patients in the RVS group experienced postoperative complications of a Clavien score ≥2, with 3 patients experiencing such complications in the US group. RVS-guided renal puncture was effective, with a lower incidence of bleeding-related complications compared with US-guided puncture. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Usefulness of real-time three-dimensional ultrasonography in percutaneous nephrostomy: an animal study.

    PubMed

    Hongzhang, Hong; Xiaojuan, Qin; Shengwei, Zhang; Feixiang, Xiang; Yujie, Xu; Haibing, Xiao; Gallina, Kazobinka; Wen, Ju; Fuqing, Zeng; Xiaoping, Zhang; Mingyue, Ding; Huageng, Liang; Xuming, Zhang

    2018-05-17

    To evaluate the effect of real-time three-dimensional (3D) ultrasonography (US) in guiding percutaneous nephrostomy (PCN). A hydronephrosis model was devised in which the ureters of 16 beagles were obstructed. The beagles were divided equally into groups 1 and 2. In group 1, the PCN was performed using real-time 3D US guidance, while in group 2 the PCN was guided using two-dimensional (2D) US. Visualization of the needle tract, length of puncture time and number of puncture times were recorded for the two groups. In group 1, score for visualization of the needle tract, length of puncture time and number of puncture times were 3, 7.3 ± 3.1 s and one time, respectively. In group 2, the respective results were 1.4 ± 0.5, 21.4 ± 5.8 s and 2.1 ± 0.6 times. The visualization of needle tract in group 1 was superior to that in group 2, and length of puncture time and number of puncture times were both lower in group 1 than in group 2. Real-time 3D US-guided PCN is superior to 2D US-guided PCN in terms of visualization of needle tract and the targeted pelvicalyceal system, leading to quick puncture. Real-time 3D US-guided puncture of the kidney holds great promise for clinical implementation in PCN. © 2018 The Authors BJU International © 2018 BJU International Published by John Wiley & Sons Ltd.

  11. The Explorer XVI Micrometeoroid Satellite Description and Preliminary Results for the Period December 16, 1962 Through January 13, 1963

    NASA Technical Reports Server (NTRS)

    Hastings, E. C., Jr.

    1963-01-01

    Explorer XVI (1962 Beta Chi l) data that have been analyzed for the period between December 16, 1962 (launch date), and January 13, 1963, indicate that the orbit achieved was close to the predicted orbit. Ten punctures of annealed 0.001-inch-thick beryllium-copper have been used to determine a puncture rate of 0.035 per square foot per day in this material. One puncture of a 0.002-inch-thick sample has also occurred in this period. A tentative evaluation of the puncture rate for the 0.001-inch beryllium-copper in terms of the rate for an equivalent thickness of aluminum has been attempted, and the result has been compared with two different puncture rate estimates. The three micrometeoroid impact detecting systems are operating. Counting rates for the high- and low-sensitivity systems were close to anticipated values near the end of one week. Two of the 0.001-inch-steel-covered grid detectors have been punctured, but none of the 0.003- or 0.006-inch-steel-covered grid detectors have indicated punctures. One of the cadmium sulfide cells indicates three punctures of the 0.00025-inch Mylar cover. None of the 0.002- or 0.003-inch-copper-wire cards have indicated a break in the period covered. Telemetry temperatures were initially higher than expected although they remained well within operating limits. Sensor temperatures have remained within the expected bounds.

  12. Cross-Layer Design for Robust and Scalable Video Transmission in Dynamic Wireless Environment

    DTIC Science & Technology

    2011-02-01

    code rate convolutional codes or prioritized Rate - Compatible Punctured ...34New rate - compatible punctured convolutional codes for Viterbi decoding," IEEE Trans. Communications, Volume 42, Issue 12, pp. 3073-3079, Dec...Quality of service RCPC Rate - compatible and punctured convolutional codes SNR Signal to noise

  13. Evaluation of semi-empirical analyses for railroad tank car puncture velocity, part 2 : correlations with engineering analysis

    DOT National Transportation Integrated Search

    2001-11-01

    This report is the second in a series focusing on methods to determine the puncture velocity of railroad tank car shells. In this : context, puncture velocity refers to the impact velocity at which a coupler will completely pierce the shell and punct...

  14. Diagnostic Lumbar Puncture

    PubMed Central

    Doherty, Carolynne M; Forbes, Raeburn B

    2014-01-01

    Diagnostic Lumbar Puncture is one of the most commonly performed invasive tests in clinical medicine. Evaluation of an acute headache and investigation of inflammatory or infectious disease of the nervous system are the most common indications. Serious complications are rare, and correct technique will minimise diagnostic error and maximise patient comfort. We review the technique of diagnostic Lumbar Puncture including anatomy, needle selection, needle insertion, measurement of opening pressure, Cerebrospinal Fluid (CSF) specimen handling and after care. We also make some quality improvement suggestions for those designing services incorporating diagnostic Lumbar Puncture. PMID:25075138

  15. Point of impact: the effect of size and speed on puncture mechanics

    PubMed Central

    Anderson, P. S. L.; LaCosse, J.; Pankow, M.

    2016-01-01

    The use of high-speed puncture mechanics for prey capture has been documented across a wide range of organisms, including vertebrates, arthropods, molluscs and cnidarians. These examples span four phyla and seven orders of magnitude difference in size. The commonality of these puncture systems offers an opportunity to explore how organisms at different scales and with different materials, morphologies and kinematics perform the same basic function. However, there is currently no framework for combining kinematic performance with cutting mechanics in biological puncture systems. Our aim here is to establish this framework by examining the effects of size and velocity in a series of controlled ballistic puncture experiments. Arrows of identical shape but varying in mass and speed were shot into cubes of ballistic gelatine. Results from high-speed videography show that projectile velocity can alter how the target gel responds to cutting. Mixed models comparing kinematic variables and puncture patterns indicate that the kinetic energy of a projectile is a better predictor of penetration than either momentum or velocity. These results form a foundation for studying the effects of impact on biological puncture, opening the door for future work to explore the influence of morphology and material organization on high-speed cutting dynamics. PMID:27274801

  16. Reliability and performance of innovative surgical double-glove hole puncture indication systems.

    PubMed

    Edlich, Richard F; Wind, Tyler C; Heather, Cynthia L; Thacker, John G

    2003-01-01

    During operative procedures, operating room personnel wear sterile surgical gloves designed to protect them and their patients against transmissible infections. The Food and Drug Administration (FDA) has set compliance policy guides for manufacturers of gloves. The FDA allows surgeons' gloves whose leakage defect rates do not exceed 1.5 acceptable quality level (AQL) to be used in operating rooms. The implications of this policy are potentially enormous to operating room personnel and patients. This unacceptable risk to the personnel and patient could be significantly reduced by the use of sterile double surgical gloves. Because double-gloves are also susceptible to needle puncture, a double-glove hole indication system is urgently needed to immediately detect surgical needle glove punctures. This warning would allow surgeons to remove the double-gloves, wash their hands, and then don a sterile set of double-gloves with an indication system. During the last decade, Regent Medical has devised non-latex and latex double-glove hole puncture indication systems. The purpose of this comprehensive study is to detect the accuracy of the non-latex and latex double-glove hole puncture indication systems using five commonly used sterile surgical needles: the taper point surgical needle, tapercut surgical needle, reverse cutting edge surgical needle, taper cardiopoint surgical needle, and spatula surgical needle. After subjecting both the non-latex and latex double-glove hole puncture indication systems to surgical needle puncture in each glove fingertip, these double-glove systems were immersed in a sterile basin of saline, after which the double-gloved hands manipulated surgical instruments. Within two minutes, both the non-latex and latex hole puncture indication systems accurately detected needle punctures in all of the surgical gloves, regardless of the dimensions of the surgical needles. In addition, the size of the color change visualized through the translucent outer glove did not correlate with needle diameter. On the basis of this extensive experimental evaluation, both the non-latex and latex double-glove hole puncture indication systems should be used in all operative procedures by all operating room personnel.

  17. In vitro fenestration of aortic stent-grafts: implications of puncture methods for in situ fenestration durability.

    PubMed

    Riga, Celia V; Bicknell, Colin D; Basra, Melvinder; Hamady, Mohamad; Cheshire, Nicholas J W

    2013-08-01

    To investigate the quality of stent-graft fenestrations created in vitro using different needle puncture and balloon dilation angles in different commercial endografts. Fenestrations were made in a standardized fashion in 3 different endograft types: Talent monofilament twill woven polyester, Zenith multifilament tubular woven polyester, and Endofit thin-walled expanded polytetrafluoroethylene (PTFE). Punctures were made at 30°, 60°, and 90° angles using a 20-G needle and dilated using 6-mm standard and 7-mm cutting balloons; at least 6 fenestrations were made at each angle with standard balloons and at least 6 with cutting balloons. The 137 fenestrations were examined under light microscopy; quantitative and qualitative digital image analysis was performed to determine size, shape, and fenestration quality. PTFE grafts were easier to puncture/dilate, resulting in larger, elliptical fenestrations with overall better quality than the Dacron grafts; however, the puncture/dilation angle made an impact on the shape and quality of fenestrations. A significant number of fabric tears were observed in PTFE fabric at <90° puncture/dilation angles compared to Dacron grafts. In Dacron grafts, fenestration quality was significantly higher with 90° puncture/dilation angles (higher in Talent grafts). Cutting balloon use resulted in significantly more fabric tears and poor quality fenestrations in all graft types. Different endografts behave significantly differently when fenestrations are fashioned. Optimum puncture/dilation is important when considering in vivo fenestration techniques. Improvements in instrumentation, materials, and techniques are required to make this a reliable and reproducible endovascular option.

  18. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  19. Design of Intelligent Cross-Layer Routing Protocols for Airborne Wireless Networks Under Dynamic Spectrum Access Paradigm

    DTIC Science & Technology

    2011-05-01

    rate convolutional codes or the prioritized Rate - Compatible Punctured ...Quality of service RCPC Rate - compatible and punctured convolutional codes SNR Signal to noise ratio SSIM... Convolutional (RCPC) codes . The RCPC codes achieve UEP by puncturing off different amounts of coded bits of the parent code . The

  20. 16 CFR 1500.18 - Banned toys and other banned articles intended for use by children.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., or loose small objects that have the potential for causing lacerations, puncture wound injury... deliberately removed by a child, which toy has the potential for causing laceration, puncture wound injury... external components that have the potential for causing laceration, puncture wound injury, or other similar...

  1. Noninvasive Assessment of Intracranial Pressure Status in Idiopathic Intracranial Hypertension Using Displacement Encoding with Stimulated Echoes (DENSE) MRI: A Prospective Patient Study with Contemporaneous CSF Pressure Correlation.

    PubMed

    Saindane, A M; Qiu, D; Oshinski, J N; Newman, N J; Biousse, V; Bruce, B B; Holbrook, J F; Dale, B M; Zhong, X

    2018-02-01

    Intracranial pressure is estimated invasively by using lumbar puncture with CSF opening pressure measurement. This study evaluated displacement encoding with stimulated echoes (DENSE), an MR imaging technique highly sensitive to brain motion, as a noninvasive means of assessing intracranial pressure status. Nine patients with suspected elevated intracranial pressure and 9 healthy control subjects were included in this prospective study. Controls underwent DENSE MR imaging through the midsagittal brain. Patients underwent DENSE MR imaging followed immediately by lumbar puncture with opening pressure measurement, CSF removal, closing pressure measurement, and immediate repeat DENSE MR imaging. Phase-reconstructed images were processed producing displacement maps, and pontine displacement was calculated. Patient data were analyzed to determine the effects of measured pressure on pontine displacement. Patient and control data were analyzed to assess the effects of clinical status (pre-lumbar puncture, post-lumbar puncture, or control) on pontine displacement. Patients demonstrated imaging findings suggesting chronically elevated intracranial pressure, whereas healthy control volunteers demonstrated no imaging abnormalities. All patients had elevated opening pressure (median, 36.0 cm water), decreased by the removal of CSF to a median closing pressure of 17.0 cm water. Patients pre-lumbar puncture had significantly smaller pontine displacement than they did post-lumbar puncture after CSF pressure reduction ( P = .001) and compared with controls ( P = .01). Post-lumbar puncture patients had statistically similar pontine displacements to controls. Measured CSF pressure in patients pre- and post-lumbar puncture correlated significantly with pontine displacement ( r = 0.49; P = .04). This study establishes a relationship between pontine displacement from DENSE MR imaging and measured pressure obtained contemporaneously by lumbar puncture, providing a method to noninvasively assess intracranial pressure status in idiopathic intracranial hypertension. © 2018 by American Journal of Neuroradiology.

  2. Clinical value of a self-designed training model for pinpointing and puncturing trigeminal ganglion.

    PubMed

    He, Yu-Quan; He, Shu; Shen, Yun-Xia; Qian, Cheng

    2014-04-01

    OBJECTIVES. A training model was designed for learners and young physicians to polish their skills in clinical practices of pinpointing and puncturing trigeminal ganglion. METHODS. A head model, on both cheeks of which the deep soft tissue was replaced by stuffed organosilicone and sponge while the superficial soft tissue, skin and the trigeminal ganglion were made of organic silicon rubber for an appearance of real human being, was made from a dried skull specimen and epoxy resin. Two physicians who had experiences in puncturing foramen ovale and trigeminal ganglion were selected to test the model, mainly for its appearance, X-ray permeability, handling of the puncture, and closure of the puncture sites. Four inexperienced physicians were selected afterwards to be trained combining Hartel's anterior facial approach with the new method of real-time observation on foramen ovale studied by us. RESULTS. Both appearance and texture of the model were extremely close to those of a real human. The fact that the skin, superficial soft tissue, deep muscles of the cheeks, and the trigeminal ganglion made of organic silicon rubber all had great elasticity resulted in quick closure and sealing of the puncture sites. The head model made of epoxy resin had similar X-ray permeability to a human skull specimen under fluoroscopy. The soft tissue was made of radiolucent material so that the training can be conducted with X-ray guidance. After repeated training, all the four young physicians were able to smoothly and successfully accomplish the puncture. CONCLUSION. This self-made model can substitute for cadaver specimen in training learners and young physicians on foramen ovale and trigeminal ganglion puncture. It is very helpful for fast learning and mastering this interventional operation skill, and the puncture accuracy can be improved significantly with our new method of real-time observation on foramen ovale.

  3. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    PubMed

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p < 0.001). The rates of hemolysis and mean potassium value were greater in samples obtained using the insulin needle compared to the standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p < 0.001) and at 24 hours postprocedure (5.4% vs. 34.2%; p = 0.007). Arterial punctures using insulin needles cause less pain and fewer procedural complications compared to standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  4. Influence of transvaginal ultrasound-guided follicular punctures in the mare on heart rate, respiratory rate, facial expression changes, and salivary cortisol as pain scoring.

    PubMed

    Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène

    2016-10-15

    Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki

    There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.

  6. Comparing the Effect of 3 Kinds of Different Materials on the Hemostasis of the Central Venous Catheter

    NASA Astrophysics Data System (ADS)

    Li, Yan-Ming; Liang, Zhen-Zhen; Song, Chun-Lei

    2016-05-01

    To compare the effect of 3 kinds of different materials on the hemostasis of puncture site after central venous catheterization. Method: A selection of 120 patients with peripheral central venous catheter chemotherapy in the Affiliated Hospital of our university from January 2014 to April 2015, Randomly divided into 3 groups, using the same specification (3.5cm × 2cm) alginate gelatin sponge and gauze dressing, 3 kinds of material compression puncture point, 3 groups of patients after puncture 24 h within the puncture point of local blood and the catheter after the catheter 72 h within the catheter maintenance costs. Result: (1) The local infiltration of the puncture point in the 24 h tube: The use of alginate dressing and gelatin sponge hemostatic effect is better than that of compression gauze. The difference was statistically significant (P <0.05). Compared with gelatin sponge and alginate dressing hemostatic effect, The difference was not statistically significant. (2) Tube maintenance cost: Puncture point using gelatin sponge, The local maintenance costs of the catheter within 72 h after insertion of the tube are lowest, compared with alginate dressing and gauze was significant (P<0.05). Conclusion: The choice of compression hemostasis material for the puncture site after PICC implantation, using gelatin sponge and gauze dressing is more effective and economic.

  7. Scalable Video Transmission Over Multi-Rate Multiple Access Channels

    DTIC Science & Technology

    2007-06-01

    Rate - compatible punctured convolutional codes (RCPC codes ) and their ap- plications,” IEEE...source encoded using the MPEG-4 video codec. The source encoded bitstream is then channel encoded with Rate Compatible Punctured Convolutional (RCPC...Clark, and J. M. Geist, “ Punctured convolutional codes or rate (n-1)/n and simplified maximum likelihood decoding,” IEEE Transactions on

  8. Experience and nursing needs of school-age children undergoing lumbar puncture during the treatment of acute lymphoblastic leukaemia: a descriptive and qualitative study.

    PubMed

    Xie, Anwei; Shan, Yuying; Niu, Mei E; Chen, Yi; Wang, Xiya

    2017-11-01

    To describe experiences and nursing needs of school-age Chinese children undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia. Lumbar puncture is an invasive procedure, causing psychological changes and physical discomfort in patients. In a previous study, it was proved that distraction intervention, such as music therapy, relieves pain and anxiety. There is limited evidence regarding the experience and needs of school-age children during lumbar puncture after being diagnosed with acute lymphoblastic leukaemia. To minimise their anxiety and pain during the procedure, it is important to collect information directly from these children. A descriptive qualitative research. Twenty-one school-age children with acute lymphoblastic leukaemia participated in semi-structured interviews at a Children's Hospital in China. Data were collected by an experienced and trained interviewer. Qualitative content analysis was chosen to describe experiences of children undergoing lumbar puncture. While undergoing lumbar puncture for the treatment of acute lymphoblastic leukaemia, school-age Chinese children experienced complex psychological feelings (fear, tension, helplessness, sadness and anxiety). They also experienced physical discomfort. They had multipolar needs, such as information, communication, respect, self-actualisation, environment and equipment. This study identified important areas that must be closely monitored by healthcare staff, performing lumbar puncture on acute lymphoblastic leukaemia children. Thus, a successful and smooth procedure can be performed on these patients, and their quality of life can be improved. The experiences described in this study contribute to a better understanding of the needs of acute lymphoblastic leukaemia children undergoing lumbar puncture. They also provide valuable information to professional medical care staff that develops future nursing assessments. © 2016 John Wiley & Sons Ltd.

  9. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    PubMed

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.

  10. Numerical method for computing Maass cusp forms on triply punctured two-sphere

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, K. T.; Kamari, H. M.; Zainuddin, H.

    2014-03-05

    A quantum mechanical system on a punctured surface modeled on hyperbolic space has always been an important subject of research in mathematics and physics. This corresponding quantum system is governed by the Schrödinger equation whose solutions are the Maass waveforms. Spectral studies on these Maass waveforms are known to contain both continuous and discrete eigenvalues. The discrete eigenfunctions are usually called the Maass Cusp Forms (MCF) where their discrete eigenvalues are not known analytically. We introduce a numerical method based on Hejhal and Then algorithm using GridMathematica for computing MCF on a punctured surface with three cusps namely the triplymore » punctured two-sphere. We also report on a pullback algorithm for the punctured surface and a point locater algorithm to facilitate the complete pullback which are essential parts of the main algorithm.« less

  11. Post-dural puncture headache

    PubMed Central

    Ghaleb, Ahmed; Khorasani, Arjang; Mangar, Devanand

    2012-01-01

    Since August Bier reported the first case in 1898, post-dural puncture headache (PDPH) has been a problem for patients following dural puncture. Clinical and laboratory research over the last 30 years has shown that use of smaller-gauge needles, particularly of the pencil-point design, are associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients < 50 years, post-partum, in the event a large-gauge needle puncture is initiated, an epidural blood patch should be performed within 24–48 hours of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications caused by autologous epidural blood patching (AEBP) are rare. PMID:22287846

  12. Postdural Puncture Headache

    PubMed Central

    Ghaleb, Ahmed

    2010-01-01

    Postdural puncture headache (PDPH) has been a problem for patients, following dural puncture, since August Bier reported the first case in 1898. His paper discussed the pathophysiology of low-pressure headache resulting from leakage of cerebrospinal fluid (CSF) from the subarachnoid to the epidural space. Clinical and laboratory research over the last 30 years has shown that use of small-gauge needles, particularly of the pencil-point design, is associated with a lower risk of PDPH than traditional cutting point needle tips (Quincke-point needle). A careful history can rule out other causes of headache. A postural component of headache is the sine qua non of PDPH. In high-risk patients , for example, age < 50 years, postpartum, large-gauge needle puncture, epidural blood patch should be performed within 24–48 h of dural puncture. The optimum volume of blood has been shown to be 12–20 mL for adult patients. Complications of AEBP are rare. PMID:20814596

  13. Identification of the lumbar interspinous spaces by palpation and verified by X-rays.

    PubMed

    Tanaka, Kei; Irikoma, Shingo; Kokubo, Sotaro

    2013-01-01

    Palpation has been shown to be rather inaccurate at identifying lumbar interspinous spaces in neuraxial anesthesia. The aim of this study is to assess the accuracy of the determination of the lumbar interspinous spaces by anesthesiologist's palpation using postoperative X-rays in obstetric patients. We reviewed the anesthetic record and the post-operative abdominal X-rays of the cesarean sections. We indwelled the epidural catheter for post-operative one-shot analgesia. We included combined spinal and epidural anesthesia cases and compared the interspinous level which the anesthesiologist recorded and the epidural catheter insertion level confirmed by abdominal X-ray for each case. We also evaluated the factors (age, body weight, height, Body Mass Index, gestational age, and the type of surgery [planned / emergency]) leading to misidentification of interspinous level. Nine hundred and sixty seven cesarean sections were performed and a total of 835 cases were evaluated. The levels of the puncture documented by the anesthesiologists were in agreement with the actual catheter insertion levels in 563 (67%) cases. When the anesthesiologists aimed at L2-3 level, we found the catheter insertion at L1-2 in 5 cases (4.9%), none of which had any post-operative neurological deficits. No variables evaluated were significantly associated with misidentification of interspinous level by the anesthesiologists. There was a discrepancy between the anesthesiologists' estimation by palpation and the actual catheter insertion level shown in X-rays. It seems to be safer to choose the interspinous level L3-4 or lower in spinal anesthesia. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  14. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  15. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  16. Robot-Assisted Retinal Vein Cannulation with Force-Based Puncture Detection: Micron vs. the Steady-Hand Eye Robot*

    PubMed Central

    Gonenc, Berk; Tran, Nhat; Gehlbach, Peter; Taylor, Russell H.; Iordachita, Iulian

    2018-01-01

    Retinal vein cannulation is a demanding procedure where therapeutic agents are injected into occluded retina veins. The feasibility of this treatment is limited due to challenges in identifying the moment of venous puncture, achieving cannulation and maintaining it throughout the drug delivery period. In this study, we integrate a force-sensing microneedle with two distinct robotic systems: the handheld micromanipulator Micron, and the cooperatively controlled Steady-Hand Eye Robot (SHER). The sensed tool-to-tissue interaction forces are used to detect venous puncture and extend the robots’ standard control schemes with a new position holding mode (PHM) that assists the operator hold the needle position fixed and maintain cannulation for a longer time with less trauma on the vasculature. We evaluate the resulting systems comparatively in a dry phantom, stretched vinyl membranes. Results have shown that modulating the admittance control gain of SHER alone is not a very effective solution for preventing the undesired tool motion after puncture. However, after using puncture detection and PHM the deviation from the puncture point is significantly reduced, by 65% with Micron, and by 95% with SHER representing a potential advantage over freehand for both. PMID:28269417

  17. A novel in vivo model of puncture-induced iris neovascularization.

    PubMed

    Beaujean, Ophélie; Locri, Filippo; Aronsson, Monica; Kvanta, Anders; André, Helder

    2017-01-01

    To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances.

  18. Challenging the wisdom of puncture at the calyceal fornix in percutaneous nephrolithotripsy: feasibility and safety study with 137 patients operated via a non-calyceal percutaneous track.

    PubMed

    Kyriazis, Iason; Kallidonis, Panagiotis; Vasilas, Marinos; Panagopoulos, Vasilios; Kamal, Wissam; Liatsikos, Evangelos

    2017-05-01

    To present our experience with a central, non-calyceal puncture protocol for percutaneous nephrolithotripsy (PCNL) in an attempt to challenge the opinion of worldwide adopted calyceal puncture as the less traumatic site of percutaneous entrance into the collecting system. During 2012, a total of 137 consecutive, unselected patients were subjected to PCNL in our department. Non-calyceal punctures were performed to all cases and followed by subsequent track dilations up to 30 Fr. Perioperative and postoperative data were prospectively collected and analyzed. Mean operative time (from skin puncture to nephrostomy tube placement) was 48 min. Patients with single, multiple and staghorn stones had primary stone-free rates of 89.2, 80.4 and 66.7 % after PCNL, respectively. The overall complication rate was 10.2 %, while bleeding complications were minimal. Only 4 patients (2.9 %) required blood transfusion. Five patients (3.6 %) had Clavien Grade IIIa complications requiring an intervention for their management and none Grade IV or V. Despite the absence of evidence that non-calyceal percutaneous tracts could be a risk factor for complications, the concept of calyceal puncture has been worldwide adopted by PCNL surgeons as the sole safe percutaneous entrance into the collective system. Based on our experience, other pathways than the worldwide recognized rule, calyceal puncture, are possible and probably not as dangerous as has been previously stated.

  19. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  20. Direct right ventricular puncture for hemodynamic evaluation of a mechanical tricuspid valve prosthesis: a new indication for an old procedure.

    PubMed

    Gibson, M A; Carell, E S

    1997-11-01

    The advent of transvenous right heart catheterization has relegated direct transthoracic right ventricular puncture largely to the role of "interesting historical footnote." However, in the case of a right ventricle that is "protected" by a mechanical tricuspid valve prosthesis, direct right ventricular puncture represents a reasonable alternative for obtaining accurate hemodynamic information.

  1. Development of a new bench for puncturing of irradiated fuel rods in STAR hot laboratory

    NASA Astrophysics Data System (ADS)

    Petitprez, B.; Silvestre, P.; Valenza, P.; Boulore, A.; David, T.

    2018-01-01

    A new device for puncturing of irradiated fuel rods in commercial power plants has been designed by Fuel Research Department of CEA Cadarache in order to provide experimental data of high precision on fuel pins with various designs. It will replace the current set-up that has been used since 1998 in hot cell 2 of STAR facility with more than 200 rod puncturing experiments. Based on this consistent experimental feedback, the heavy-duty technique of rod perforation by clad punching has been preserved for the new bench. The method of double expansion of rod gases is also retained since it allows upgrading the confidence interval of volumetric results obtained from rod puncturing. Furthermore, many evolutions have been introduced in the new design in order to improve its reliability, to make the maintenance easier by remote handling and to reduce experimental uncertainties. Tightness components have been studied with Sealing Laboratory Maestral at Pierrelatte so as to make them able to work under mixed pressure conditions (from vacuum at 10-5 mbar up to pressure at 50 bars) and to lengthen their lifetime under permanent gamma irradiation in hot cell. Bench ergonomics has been optimized to make its operating by remote handling easier and to secure the critical phases of a puncturing experiment. A high pressure gas line equipped with high precision pressure sensors out of cell can be connected to the bench in cell for calibration purposes. Uncertainty analyses using Monte Carlo calculations have been performed in order to optimize capacity of the different volumes of the apparatus according to volumetric characteristics of the rod to be punctured. At last this device is composed of independent modules which allow puncturing fuel pins out of different geometries (PWR, BWR, VVER). After leak tests of the device and remote handling simulation in a mock-up cell, several punctures of calibrated specimens have been performed in 2016. The bench will be implemented soon in hot cell 2 of STAR facility for final qualification tests. PWR rod punctures are already planned for 2018.

  2. Access site complications and puncture site pain following transradial coronary procedures: a correlational study.

    PubMed

    Cheng, Ka Yan; Chair, Sek Ying; Choi, Kai Chow

    2013-10-01

    Transradial coronary angiography (CA) and percutaneous coronary intervention (PCI) are gaining worldwide popularity due to the low incidence of major vascular complications and early mobilization of patients post procedures. Although post transradial access site complications are generally considered as minor in nature, they are not being routinely recorded in clinical settings. To evaluate the incidence of access site complications and level of puncture site pain experienced by patients undergoing transradial coronary procedures and to examine factors associated with access site complications occurrence and puncture site pain severity. A cross-sectional correlational study of 85 Chinese speaking adult patients scheduled for elective transradial CA and or PCI. Ecchymosis, bleeding, hematoma and radial artery occlusion (RAO) were assessed through observation, palpation and plethysmographic signal of pulse oximetry after coronary procedures. Puncture site pain was assessed with a 100mm Visual Analogue Scale. Factors that were related to access site complications and puncture site pain were obtained from medical records. Ecchymosis was the most commonly reported transradial access site complication in this study. Paired t-test showed that the level of puncture site pain at 24 h was significantly (p<0.001) lower than that at 3 h after the procedure. Stepwise multivariable regression showed that female gender and shorter sheath time were found to be significantly associated with bleeding during gradual deflation of compression device. Only longer sheath time was significantly associated with RAO. Female gender and larger volume of compression air were associated with the presence of ecchymosis and puncture site pain at 3 h after procedure, respectively. The study findings suggest that common access site complications post transradial coronary procedures among Chinese population are relatively minor in nature. Individual puncture site pain assessment during the period of hemostasis is important. Nurses should pay more attention to factors such as female gender, sheath time and volume of compression that are more likely to be associated with transradial access site complications and puncture site pain. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Puncture Reduction in Percutaneous Transforaminal Endoscopic Discectomy with HE's Lumbar LOcation (HELLO) System: A Cadaver Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Sun, Qi; Hu, Annan; Zhu, Yanjie; Gu, Guangfei; Zhang, Hailong; He, Shisheng

    2015-01-01

    Percutaneous transforaminal endoscopic discectomy (PTED) usually requires numerous punctures under X-ray fluoroscopy. Repeated puncture will lead to more radiation exposure and reduce the beginners' confidence. This cadaver study aimed to investigate the efficacy of HE's Lumbar Location (HELLO) system in puncture reduction of PTED. Cadaver study. Comparative groups. HELLO system consists of self-made surface locator and puncture locator. One senior surgeon conducted the puncture procedure of PTED on the left side of 20 cadavers at L4/L5 and L5/S1 level with the assistance of HELLO system (Group A). Additionally, the senior surgeon conducted the puncture procedure of PTED on the right side of the cadavers at L4/L5 and L5/S1 level with traditional methods (Group B). On the other hand, an inexperienced surgeon conducted the puncture procedure of PTED on the left side of the cadavers at L4/L5 and L5/S1 level with the assistance of our HELLO system (Group C). At L4/L5 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.811). Similarly at L5/S1 level, there was significant difference in puncture times between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.981). At L4/L5 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.290). Similarly at L5/S1 level, there was significant difference in fluoroscopy time between Group A and Group B (P<0.001), but no significant difference was observed between Group A and Group C (P = 0.523). As for radiation exposure, HELLO system reduced 39%-45% radiation dosage when comparing Group A and Group B, but there was no significant difference in radiation exposure between Group A and Group C whatever at L4/L5 level or L5/S1 level (P>0.05). There was no difference in location time between Group A and Group B or Group A and Group C either at L4/L5 level or L5/S1 level (P>0.05). Small-sample preclinical study. HELLO system was effective in reducing puncture times, fluoroscopy time and radiation exposure, as well as the difficulty of learning PTED. (2015-RES-127).

  4. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  5. Use of Lumbar Punctures in the Management of Ocular Syphilis.

    PubMed

    Reekie, Ian; Reddy, Yaviche

    2018-01-01

    Ocular syphilis has become rare in the developed world, but is a common presentation to ophthalmology departments in South Africa. We investigated the proportion of patients diagnosed with ocular syphilis who went on to receive lumbar punctures, and determined the fraction of these who had cerebrospinal fluid findings suggestive of neurosyphilis. We aimed to determine whether the use of lumbar punctures in ocular syphilis patients was beneficial in picking up cases of neurosyphilis. Retrospective study of case notes of patients admitted to two district hospitals in Durban, South Africa, with ocular syphilis over a 20-month period. A total of 31 of 68 ocular syphilis patients underwent lumbar puncture, and of these, eight (25.8%) had findings suggestive of neurosyphilis. Lumbar puncture in ocular syphilis patients should continue to be a routine part of the investigation of these patients; a large proportion of ocular syphilis patients show cerebrospinal fluid findings suggestive of neurosyphilis, are at risk of the complications of neurosyphilis, and should be managed accordingly.

  6. Performance Analysis of IEEE 802.11g TCM Waveforms Transmitted over a Channel with Pulse-Noise Interference

    DTIC Science & Technology

    2007-06-01

    17 Table 2. Best (maximum free distance) rate r=2/3 punctured convolutional code ...Hamming distance between all pairs of non-zero paths. Table 2 lists the best rate r=2/3, punctured convolutional code information weight structure dB...Table 2. Best (maximum free distance) rate r=2/3 punctured convolutional code information weight structure. (From: [12]). K freed freeB

  7. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    PubMed

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  8. DNA duplication is essential for the repair of gastrointestinal perforation in the insect midgut

    PubMed Central

    Huang, Wuren; Zhang, Jie; Yang, Bing; Beerntsen, Brenda T.; Song, Hongsheng; Ling, Erjun

    2016-01-01

    Invertebrate animals have the capacity of repairing wounds in the skin and gut via different mechanisms. Gastrointestinal perforation, a hole in the human gastrointestinal system, is a serious condition, and surgery is necessary to repair the perforation to prevent an abdominal abscess or sepsis. Here we report the repair of gastrointestinal perforation made by a needle-puncture wound in the silkworm larval midgut. Following insect gut perforation, only a weak immune response was observed because the growth of Escherichia coli alone was partially inhibited by plasma collected at 6 h after needle puncture of the larval midgut. However, circulating hemocytes did aggregate over the needle-puncture wound to form a scab. While, cell division and apoptosis were not observed at the wound site, the needle puncture significantly enhanced DNA duplication in cells surrounding the wound, which was essential to repair the midgut perforation. Due to the repair capacity and limited immune response caused by needle puncture to the midgut, this approach was successfully used for the injection of small compounds (ethanol in this study) into the insect midgut. Consequently, this needle-puncture wounding of the insect gut can be developed for screening compounds for use as gut chemotherapeutics in the future. PMID:26754166

  9. A novel in vivo model of puncture-induced iris neovascularization

    PubMed Central

    Aronsson, Monica; Kvanta, Anders

    2017-01-01

    Purpose To assess iris neovascularization by uveal puncture of the mouse eye and determine the role of angiogenic factors during iris neovascularization. Methods Uveal punctures were performed on BalbC mouse eyes to induce iris angiogenesis. VEGF-blockage was used as an anti-angiogenic treatment, while normoxia- and hypoxia-conditioned media from retinal pigment epithelium (RPE) cells was used as an angiogenic-inducer in this model. Iris vasculature was determined in vivo by noninvasive methods. Iris blood vessels were stained for platelet endothelial cell adhesion molecule-1 and vascular sprouts were counted as markers of angiogenesis. Expression of angiogenic and inflammatory factors in the puncture-induced model were determined by qPCR and western blot. Results Punctures led to increased neovascularization and sprouting of the iris. qPCR and protein analysis showed an increase of angiogenic factors, particularly in the plasminogen-activating receptor and inflammatory systems. VEGF-blockage partly reduced iris neovascularization, and treatment with hypoxia-conditioned RPE medium led to a statistically significant increase in iris neovascularization. Conclusions This study presents the first evidence of a puncture-induced iris angiogenesis model in the mouse. In a broader context, this novel in vivo model of neovascularization has the potential for noninvasive evaluation of angiogenesis modulating substances. PMID:28658313

  10. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

    PubMed

    Duan, Xu; Ling, Feng; Shen, Yun; Yang, Jun; Xu, Hai-ying; Tong, Xiao-shan

    2013-04-01

    We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group. Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

  11. Incidence of tissue coring during transseptal catheterization when using electrocautery and a standard transseptal needle.

    PubMed

    Greenstein, Eugene; Passman, Rod; Lin, Albert C; Knight, Bradley P

    2012-04-01

    The application of radiofrequency electrocautery to a standard, open-ended transseptal needle has been used to facilitate transseptal puncture (TSP). The purpose of this study was to determine the incidence of cardiac tissue coring when this technique is used. A model using excised swine hearts submerged in a saline-filled basin was developed to simulate TSP with electrocautery and a standard transseptal needle. Punctures were performed without the use of electrocautery and by delivering radiofrequency energy to the transseptal needle using a standard electrocautery pen at 3 target sites (fossa ovalis, non-fossa ovalis septum, and aorta). The tissue of the submerged heart was gently tented, and the needle was advanced on delivery of radiofrequency. The devices were retracted, and the needle was flushed in a collection basin. None of the TSPs without cautery caused tissue coring. For TSPs using electrocautery, the frequency of coring was at least 21% for any puncture permutation used in the study and averaged 37% at septal sites (P<0.001 compared with punctures without cautery). Tissue coring occurred in 33 of 96 (35%) punctures through the fossa ovalis and in 38 of 96 (40%) punctures through non-fossa ovalis septum. The frequency of tissue coring at aortic sites was 62 of 96 (65%), which was significantly higher than at the septal sites (P<0.001). In an animal preparation, TSP at the level of the fossa ovalis using electrocautery and a standard open-ended Brockenbrough needle resulted in coring of the septal tissue in 35% of cases (33 of 96 punctures).

  12. Causes and Solutions of the Trampoline Effect.

    PubMed

    Miwa, Masamiki; Ota, Noboru; Ando, Chiyono; Miyazaki, Yukio

    2015-01-01

    A trampoline effect may occur mainly when a buttonhole tract and the vessel flap fail to form a straight line. Certain findings, however, suggest another cause is when the vessel flap is too small. The frequency of the trampoline effect, for example, is lower when a buttonhole tract is created by multiple punctures of the arteriovenous fistula (AVF) vessel than when it is done by one-time puncture of the vessel. Lower frequency of the trampoline effect with multiple punctures of the AVF vessel may be due to enlargement of the initial puncture hole on the vessel every time the vessel is punctured with a sharp needle. Even if aiming at exactly the same point on the AVF vessel every time, the actual puncture point shifts slightly at every puncture, which potentially results in enlargement of the initial hole on the AVF vessel. Moreover, in some patients, continued use of a buttonhole tract for an extended period of time increases the frequency of the trampoline effect. In such cases, reduction of the incidence of the trampoline effect can be achieved by one buttonhole cannulation using a new dull needle with sharp side edges that is used to enlarge the vessel flap. Such single buttonhole cannulation may suggest that the increased frequency of the trampoline effect also potentially occurs in association with gradually diminishing flap size. As a final observation, dull needle insertion into a vessel flap in the reverse direction has been more smoothly achieved than insertion into a vessel flap in the conventional direction. A vessel flap in the reverse direction can be adopted clinically. © 2015 S. Karger AG, Basel.

  13. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    PubMed

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  14. Pitfalls in the diagnostic evaluation of subacute combined degeneration.

    PubMed

    Ulrich, A; Müller, D; Linnebank, M; Tarnutzer, A A

    2015-05-14

    We report a case of a 43-year-old man presenting with a 2-week history of painless ascending sensory disturbances, suspected to be suffering from acute inflammatory polyneuropathy. On clinical examination, deep tendon reflexes were preserved and muscle strength was 5/5 everywhere. Gait was ataxic with positive Romberg test. Lumbar puncture was normal and electroneurography demonstrated demyelination. With spinal cord involvement centred on the posterior tracts on MRI, differential diagnosis focused on cobalamin deficiency. Initial laboratory work up showed nearly normal holotranscobalamin (43 pmol/L, normal>50) suggesting no vitamin B12 deficiency. Surprisingly, further testing including methylmalonic acid (3732 nmol/L, normal<271) and homocysteine (48.5 µmol/L, normal<10) showed an impairment of vitamin B12-dependent metabolism leading to the diagnosis of subacute combined degeneration. Only after repeated history taking did the patient remember having taken tablets containing cobalamin for 3 days before hospitalisation. In case of B12 deficiency, holotranscobalamin can rapidly normalise during supplementation, whereas methylmalonic acid and homocysteine might help to detect B12 deficiency in patients who recently started supplementation. 2015 BMJ Publishing Group Ltd.

  15. Inexpensive homemade models for ultrasound-guided vein cannulation training.

    PubMed

    Di Domenico, Stefano; Santori, Gregorio; Porcile, Elisa; Licausi, Martina; Centanaro, Monica; Valente, Umberto

    2007-11-01

    To test the hypothesis that low-cost homemade models may be used to acquire the basic skills for ultrasound-guided central vein puncture. Training study. University transplantation department. Training was performed using three different homemade models (A, B, and C). Segments of a common rubber tourniquet (V1) and Silastic tube (V2) were used to simulate vessels within agar-based models. Overall cost for each model was less than 5 euro (US$7). For each test (test I, A-V1; II, A-V2; III, B-V1; IV, C-V2), the number of punctures and attempts needed to locate the needle inside the lumen were recorded. Each test was considered completed when participants punctured the vessels at the first attempt for three consecutive times. In test I, the mean number of punctures and attempts were 3.85 +/- 1.26 and 4.95 +/- 3.05; in test II, 4.60 +/- 1.14 and 6.30 +/- 2.51; in test III, 4.80 +/- 1.06 and 4.65 +/- 2.21; and in test IV, 4.45 +/- 1.23 and 6.05 +/- 2.92, respectively. For each test, no statistical difference was found by comparison of number of punctures and attempts for anesthesiologists versus nonanesthesiologists, men versus women, or previous experience versus no experience with central vein cannulation (CVC). Video game users obtained better results than did nonusers in test I (punctures, P = 0.033; attempts, P = 0.038), test II (punctures, P = 0.052; attempts, P = 0.011), and test IV (punctures, P = 0.001; attempts, P = 0.003). A posttraining questionnaire showed favorable opinions about the clarity of the instructions, aptness of the models, and adequacy of the training. In our operative unit, the use of ultrasound guidance for CVC increased from 2% to 23% in the first month after training. Low-cost homemade models are useful in acquiring basic coordination skills for ultrasound-guided CVC.

  16. The pie-crusting technique using a blade knife for medial collateral ligament release is unreliable in varus total knee arthroplasty.

    PubMed

    Kwak, Dai-Soon; In, Yong; Kim, Tae Kyun; Cho, Han Suk; Koh, In Jun

    2016-01-01

    Despite the documented clinical efficacy of the pie-crusting technique for medial collateral ligament (MCL) release in varus total knee arthroplasty, its quantitative effects on medial gaps and safety remain unclear. This study was undertaken to determine the efficacy (quantitative effect and consistency of the number of punctures) and the safety (frequency of early over-release) of the pie-crusting technique for MCL release. From ten pairs of cadaveric knees, one knee from each pair was randomly assigned to undergo pie crusting in extension (group E) or in flexion (group F). Pie crusting was performed in the superficial MCL using a blade until over-release occurred. After every puncture, the incremental medial gap increase was recorded, and the number of punctures required for 2- or 4-mm gap increases was assessed. In group E, the extension gap increased from 0.8 to 5.0 mm and the flexion gap increased from 0.8 to 3.0 mm. In group F, the extension gap increased from 1.0 to 3.0 mm and the flexion gap increased from 2.6 to 6.0 mm. However, the gap increments were inconsistent with those that followed the preceding blade punctures, and the number of punctures required to increase the gaps by 2 or 4 mm was variable. The number of punctures leading to over-release in group E and group F was 6 ± 1 and 3 ± 1 punctures, respectively. Overall, 70% of over-release occurred earlier than the average number of punctures leading to over-release. Pie crusting led to unpredictable gap increments and to frequent early over-release. Surgeons should decide carefully before using the pie-crusting technique for MCL release and should be cautious of performing throughout the procedure, especially when performing in a flexed knee. Therapeutic study, Level I.

  17. Performance Analysis of Hybrid ARQ Protocols in a Slotted Code Division Multiple-Access Network

    DTIC Science & Technology

    1989-08-01

    Convolutional Codes . in Proc Int. Conf. Commun., 21.4.1-21.4.5, 1987. [27] J. Hagenauer. Rate Compatible Punctured Convolutional Codes . in Proc Int. Conf...achieved by using a low rate (r = 0.5), high constraint length (e.g., 32) punctured convolutional code . Code puncturing provides for a variable rate code ...investigated the use of convolutional codes in Type II Hybrid ARQ protocols. The error

  18. Vascular access: the impact of ultrasonography

    PubMed Central

    de Almeida, Carlos Eduardo Saldanha

    2016-01-01

    ABSTRACT Vascular punctures are often necessary in critically ill patients. They are secure, but not free of complications. Ultrasonography enhances safety of the procedure by decreasing puncture attempts, complications and costs. This study reviews important publications and the puncture technique using ultrasound, bringing part of the experience of the intensive care unit of the Hospital Israelita Albert Einstein, São Paulo (SP), Brazil, and discussing issues that should be considered in future studies. PMID:28076607

  19. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    PubMed Central

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct. PMID:23162248

  20. [An atraumatic needle for the puncture of ports and pumps].

    PubMed

    Haindl, H; Müller, H

    1988-10-17

    Huber-point needles have been found to induce substantial coring during puncture of ports or pumps, which may lead to leakage or obturation of these devices. Therefore, different types of cannulas were tested in order to evaluate their applicability for this purpose. Pencil-point needles led to increased pain during puncture and thus seemed unsuitable. A newly developed port-cannula bent inwards within the length of the bevel ("protected bevel") and proved to be definitely noncoring during electron microscopy. Consequently the force required to introduce this needle was reduced by 50% in comparison with the Huber-type needle. In addition, this cannula allowed up to 3000 punctures of one port without leakage and, thus, correspondingly therefore relevantly increased the durability of this device.

  1. The effect of second-stage pushing and body mass index on postdural puncture headache.

    PubMed

    Franz, Amber M; Jia, Shawn Y; Bahnson, Henry T; Goel, Akash; Habib, Ashraf S

    2017-02-01

    To explore how pushing during labor and body mass index affect the development of postdural puncture headache in parturients who experienced dural puncture with Tuohy needles. Retrospective cohort. Obstetric ward and operating rooms at a university-affiliated hospital. One hundred ninety parturients who had witnessed dural puncture with 17 or 18 gauge Tuohy needles from 1999-2014. Patients were categorized by pushing status and body mass index (kg/m 2 ): nonobese <30, obese 30-39.99, morbidly obese 40-49.99, and super obese ≥50. Headache, number of days of headache, maximum headache score, and epidural blood patch placement. Compared with women who did not push, women who pushed during labor had increased risk of postdural puncture headache (odds ratio [OR], 2.1 [1.1-4.0]; P=.02), more days of headache (P=.02), and increased epidural blood patch placement (P=.02). Super obese patients were less likely to develop headache compared with nonobese (OR, 0.33 [0.13-0.85]; P=.02), obese (OR, 0.37 [0.14-0.98]; P=.045], and morbidly obese patients (OR, 0.20 [0.05-0.68]; P<.01). In a multivariate logistic regression model, lack of pushing (OR, 0.57 [0.29-1.10]; P=.096) and super obesity (OR, 0.41 [0.16-1.02]; P=.056] were no longer significantly associated with reduced risk of postdural puncture headache. Parturients who did not push before delivery and parturients with body mass index ≥50kg/m 2 were less likely to develop postdural puncture headache in a univariate analysis. Similar trends were demonstrated in a multivariate model, but were no longer statistically significant. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography.

    PubMed

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  3. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography

    PubMed Central

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Objectives Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Methods Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Results Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Conclusions Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. PMID:25634390

  4. Evolving a Puncture Black Hole with Fixed Mesh Refinement

    NASA Technical Reports Server (NTRS)

    Imbiriba, Breno; Baker, John; Choi, Dae-II; Centrella, Joan; Fiske. David R.; Brown, J. David; vanMeter, James R.; Olson, Kevin

    2004-01-01

    We present a detailed study of the effects of mesh refinement boundaries on the convergence and stability of simulations of black hole spacetimes. We find no technical problems. In our applications of this technique to the evolution of puncture initial data, we demonstrate that it is possible to simulaneously maintain second order convergence near the puncture and extend the outer boundary beyond 100M, thereby approaching the asymptotically flat region in which boundary condition problems are less difficult.

  5. Design and System Implications of a Family of Wideband HF Data Waveforms

    DTIC Science & Technology

    2010-09-01

    code rates (i.e. 8/9, 9/10) will be used to attain the highest data rates for surface wave links. Very high puncturing of convolutional codes can...Communication Links”, Edition 1, North Atlantic Treaty Organization, 2009. [14] Yasuda, Y., Kashiki, K., Hirata, Y. “High- Rate Punctured Convolutional Codes ...length 7 convolutional code that has been used for over two decades in 110A. In addition, repetition coding and puncturing was

  6. Aerosol can puncture device operational test plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leist, K.J.

    1994-05-03

    Puncturing of aerosol cans is performed in the Waste Receiving and Processing Facility Module 1 (WRAP 1) process as a requirement of the waste disposal acceptance criteria for both transuranic (TRU) waste and low-level waste (LLW). These cans have contained such things as paints, lubricating oils, paint removers, insecticides, and cleaning supplies which were used in radioactive facilities. Due to Westinghouse Hanford Company (WHC) Fire Protection concerns of the baseline system`s fire/explosion proof characteristics, a study was undertaken to compare the baseline system`s design to commercially available puncturing devices. While the study found no areas which might indicate a riskmore » of fire or explosion, WHC Fire Protection determined that the puncturing system must have a demonstrated record of safe operation. This could be obtained either by testing the baseline design by an independent laboratory, or by substituting a commercially available device. As a result of these efforts, the commercially available Aerosolv can puncturing device was chosen to replace the baseline design. Two concerns were raised with the system. Premature blinding of the coalescing/carbon filter, due to its proximity to the puncture and draining operation; and overpressurization of the collection bottle due to its small volume and by blinding of the filter assembly. As a result of these concerns, testing was deemed necessary. The objective of this report is to outline test procedures for the Aerosolv.« less

  7. Intravascular Ultrasound Guidance for Transjugular Intrahepatic Portosystemic Shunt Procedure in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kew, Jacqueline; Davies, Roger P.

    2004-01-15

    A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less

  8. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    PubMed

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. [The Huber needle as a special cannula for the puncture of implanted ports and pumps--a mistake in multiple variations].

    PubMed

    Müller, H; Zierski, J

    1988-10-03

    Huber-point needles, which are thought to be noncoring, are usually recommended for puncture of implanted drug-delivery devices, such as ports and pumps. Nevertheless, we found occlusion by silicone chips deriving from the silicone inlet septum to be a major technical complication. Electron microscopic investigations demonstrated substantial loss of material from the port membrane after repeated puncture with this type of needle. During an in vitro test, multiple puncture with Huber-type cannulas led to a pressure-dependent leakage of a port after only 150 to 750 insertions of a needle. In addition, the forces necessary for puncture or for withdrawal of the needle were increased with Huber-point needles, possibly due to a coring effect. Another disadvantage of the available port needles is the formation of a hook at the tip, which may lead to additional lesion of the port or pump membrane. In our opinion, resterilization of Huber needles, recommended by the manufactures, is not advisable, because it is well known that safe sterilization of small lumina, e.g., the lumen of the needle, is impossible.

  10. Embolization of an Internal Iliac Artery Aneurysm after Image-Guided Direct Puncture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heye, S., E-mail: sam.heye@uzleuven.be; Vaninbroukx, J.; Daenens, K.

    2012-08-15

    Objective: To evaluate the feasibility, safety, and efficacy of embolization of internal iliac artery aneurysm (IIAA) after percutaneous direct puncture under (cone-beam) computed tomography (CT) guidance. Methods: A retrospective case series of three patients, in whom IIAA not accessible by way of the transarterial route, was reviewed. CT-guided puncture of the IIAA sac was performed in one patient. Two patients underwent puncture of the IIAA under cone-beam CT guidance. Results: Access to the IIAA sac was successful in all three patients. In two of the three patients, the posterior and/or anterior division was first embolized using platinum microcoils. The aneurysmmore » sac was embolized with thrombin in one patient and with a mixture of glue and Lipiodol in two patients. No complications were seen. On follow-up CT, no opacification of the aneurysm sac was seen. The volume of one IIAA remained stable at follow-up, and the remaining two IIAAs decreased in size. Conclusion: Embolization of IIAA after direct percutaneous puncture under cone-beam CT/CT-guidance is feasible and safe and results in good short-term outcome.« less

  11. Immediate and long-term clinical outcome after spinal cord stimulation for refractory stable angina pectoris.

    PubMed

    Di Pede, Francesco; Lanza, Gaetano Antonio; Zuin, Guerrino; Alfieri, Ottavio; Rapati, Massimo; Romanò, Massimo; Circo, Antonio; Cardano, Paola; Bellocci, Fulvio; Santini, Massimo; Maseri, Attilio

    2003-04-15

    The treatment of patients with angina pectoris refractory to medical therapy and unsuitable for revascularization procedures has yet not been well standardized. Previous retrospective studies and small prospective studies have suggested beneficial effects of spinal cord stimulation (SCS) in these patients. We created a Prospective Italian Registry of SCS to evaluate the short- and long-term clinical outcome of patients who underwent SCS device implantation because of severe refractory angina pectoris. Overall, 104 patients were enrolled in the registry (70 men, aged 68 +/- 17 years), most of whom (83%) had severe coronary artery disease. Average follow-up was 13.2 +/- 8 months. Overall, 17 patients (16%) died, 8 (8%) due to cardiac death. Among clinical variables, only age was found to be significantly associated both with total mortality (p = 0.04) and cardiac mortality (p = 0.02) on Cox regression analysis. A significant improvement of anginal symptoms (> or =50% reduction of weekly anginal episodes, compared with baseline) occurred in 73% of patients, and Canadian Cardiovascular Society angina class improved by > or =1 class in 80% and by > or =2 classes in 42% of patients, with a relevant reduction in the rate of hospital admission and days spent in the hospital because of angina (p <0.0001 for both). No life-threatening or clinically serious complications were observed. The most frequent side effect consisted of superficial infections, either at the site of puncture of electrode insertion or of the abdominal pocket, which occurred in 6 patients. In conclusion, our prospective data point out that SCS can be performed safely and is associated with a sustained improvement of anginal symptoms in a relevant number of patients with refractory stable angina pectoris.

  12. A non-invasive method to produce pressure ulcers of varying severity in a spinal cord-injured rat model.

    PubMed

    Ahmed, A K; Goodwin, C R; Sarabia-Estrada, R; Lay, F; Ansari, A M; Steenbergen, C; Pang, C; Cohen, R; Born, L J; Matsangos, A E; Ng, C; Marti, G P; Abu-Bonsrah, N; Phillips, N A; Suk, I; Sciubba, D M; Harmon, J W

    2016-12-01

    Experimental study. The objective of this study was to establish a non-invasive model to produce pressure ulcers of varying severity in animals with spinal cord injury (SCI). The study was conducted at the Johns Hopkins Hospital in Baltimore, Maryland, USA. A mid-thoracic (T7-T9) left hemisection was performed on Sprague-Dawley rats. At 7 days post SCI, rats received varying degrees of pressure on the left posterior thigh region. Laser Doppler Flowmetry was used to record blood flow. Animals were killed 12 days after SCI. A cardiac puncture was performed for blood chemistry, and full-thickness tissue was harvested for histology. Doppler blood flow after SCI prior to pressure application was 237.808±16.175 PFUs at day 7. Following pressure application, there was a statistically significant decrease in blood flow in all pressure-applied groups in comparison with controls with a mean perfusion of 118.361±18.223 (P<0.001). White blood cell counts and creatine kinase for each group were statistically significant from the control group (P=0.0107 and P=0.0028, respectively). We have created a novel animal model of pressure ulcer formation in the setting of a SCI. Histological analysis revealed different stages of injury corresponding to the amount of pressure the animals were exposed to with decreased blood flow immediately after the insult along with a subsequent marked increase in blood flow the next day, conducive to an ischemia-reperfusion injury (IRI) and a possible inflammatory response following tissue injury. Following ischemia and hypoxia secondary to microcirculation impairment, free radicals generate lipid peroxidation, leading to ischemic tissue damage. Future studies should be aimed at measuring free radicals during this period of increased blood flow, following tissue ischemia.

  13. Comparison of intra-aortic computed tomography angiography to conventional angiography in the presurgical visualization of the Adamkiewicz artery: first results in patients with thoracoabdominal aortic aneurysms.

    PubMed

    Clarençon, Frédéric; Di Maria, Federico; Cormier, Evelyne; Gaudric, Julien; Sourour, Nader; Gabrieli, Joseph; Iosif, Christina; Jenny, Catherine; Koskas, Fabien; Chiras, Jacques

    2013-11-01

    The aim of this study was to compare the sensitivity of intra-aortic computed tomography angiography (IA-CTA) to that of regular spinal digital subtraction angiography for the presurgical location of the Adamkiewicz artery (AKA). Thirty patients (21 males, 9 females; mean age 64 years) had an IA-CTA for the location of the AKA before surgery of aneurysm (n = 24) or dissection (n = 6) of the thoracoabdominal aorta. After femoral artery puncture, a pigtail catheter was positioned at the origin of the descending aorta. CT acquisition was performed with an intra-aortic iodinated contrast media injection (15 mL/s, 120 mL). The visualization of the AKA and the location of the feeder(s) to the AKA were independently evaluated by two observers. Interrater agreement was calculated using a kappa test. Spinal angiogram by selective catheterization was systematically performed to confirm the results of the IA-CTA. The AKA was visualized by the IA-CTA in 27/30 cases (90 %); in 26/31 (84 %) cases, the continuity with the aorta was satisfactorily seen. Interrater agreement was good for the visualization of the AKA and its feeder(s): 0.625 and 0.87, respectively. In 75 % of the cases for which the AKA was visualized, the selective catheterization confirmed the results of the IA-CTA. In the remaining 25 % of the cases, the selective catheterization could not be performed due to marked vessels' tortuosity or ostium stenosis. IA-CTA is a feasible technique in a daily practice that presents a good sensitivity for the location of the AKA.

  14. Blood gases

    MedlinePlus

    ... Test is Performed The test is used to evaluate respiratory diseases and conditions that affect the lungs. ... may include: Bleeding at the puncture site Blood flow problems at puncture site (rare) Bruising at the ...

  15. Recent Advances in Thermoplastic Puncture-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Gordon, K. L.; Working, D. C.; Wise, K. E.; Bogert, P. B.; Britton, S. M.; Topping, C.C.; Smith, J. Y.; Siochi, E. J.

    2009-01-01

    Self-healing materials provide a route for enhanced damage tolerance in materials for aerospace applications. In particular, puncture-healing upon impact has the potential to mitigate significant damage caused by high velocity micrometeoroid impacts. This type of material also has the potential to improve damage tolerance in load bearing structures to enhance vehicle health and aircraft durability. The materials being studied are those capable of instantaneous puncture healing, providing a mechanism for mechanical property retention in lightweight structures. These systems have demonstrated healing capability following penetration of fast moving projectiles -- velocities that range from 9 mm bullets shot from a gun (approx.330 m/sec) to close to micrometeoroid debris velocities of 4800 m/sec. In this presentation, we report on a suite of polymeric materials possessing this characteristic. Figure 1 illustrates the puncture healing concept. Puncture healing in these materials is dependent upon how the combination of a polymer's viscoelastic properties responds to the energy input resulting from the puncture event. Projectile penetration increases the temperature in the vicinity of the impact. Self-healing behavior occurs following puncture, whereby energy must be transferred to the material during impact both elastically and inelastically, thus establishing two requirements for puncture healing to occur: a.) The need for the puncture event to produce a local melt state in the polymer material and b.) The molten material has to have sufficient melt elasticity to snap back and close the hole. 1,2 Previous ballistic testing studies revealed that Surlyn materials warmed up to a temperature approx.98 C during projectile puncture (3 C higher than it s melting temperature). 1,2 The temperature increase produces a localized flow state and the melt elasticity to snap back thus sealing the hole. Table 1 lists the commercially polymers studied here, together with their physical properties. The polymers were selected based on chemical structure, tensile strengths, tensile moduli, glass transition temperature, melting temperatures, and impact strength. The thermal properties of the polymers were characterized by Differential Scanning Calorimetry (DSC) and Dynamic Mechanical Analysis (DMA). Mechanical properties were assessed by a Sintech 2W instron according to ASTM D1708 or D638 at crosshead speeds of 5.08 cm/min. 7.6 cm x 7.6 cm panels of the different materials were prepared and ballistic testing was performed at various temperatures. The panels were shot with a .223 caliber semiautomatic rifle from a distance of 23 meters at various temperatures. Chronographs were used to measure initial and final bullet velocity. Temperatures at the site of impact were measured using a FLIR ThermaCAM S60 thermal camera. A Vision Research model Phantom 9 high speed video camera was used to capture high speed video footage of ballistics testing.

  16. Meteoroid detector

    NASA Technical Reports Server (NTRS)

    Mcmaster, L. R.; Peterson, S. T.; Hughes, F. M. (Inventor)

    1973-01-01

    A meteoroid detector is described which uses, a cold cathode discharge tube with a gas-pressurized cell in space for recording a meteoroid puncture of the cell and for determining the size of the puncture.

  17. Analytic convergence of harmonic metrics for parabolic Higgs bundles

    NASA Astrophysics Data System (ADS)

    Kim, Semin; Wilkin, Graeme

    2018-04-01

    In this paper we investigate the moduli space of parabolic Higgs bundles over a punctured Riemann surface with varying weights at the punctures. We show that the harmonic metric depends analytically on the weights and the stable Higgs bundle. This gives a Higgs bundle generalisation of a theorem of McOwen on the existence of hyperbolic cone metrics on a punctured surface within a given conformal class, and a generalisation of a theorem of Judge on the analytic parametrisation of these metrics.

  18. Image fusion-guided portal vein puncture during transjugular intrahepatic portosystemic shunt placement.

    PubMed

    Rouabah, K; Varoquaux, A; Caporossi, J M; Louis, G; Jacquier, A; Bartoli, J M; Moulin, G; Vidal, V

    2016-11-01

    The purpose of this study was to assess the feasibility and utility of image fusion (Easy-TIPS) obtained from pre-procedure CT angiography and per-procedure real-time fluoroscopy for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement. Eighteen patients (15 men, 3 women) with a mean age of 63 years (range: 48-81 years; median age, 65 years) were included in the study. All patients underwent TIPS placement by two groups of radiologists (one group with radiologists of an experience<3 years and one with an experience≥3 years) using fusion imaging obtained from three-dimensional computed tomography angiography of the portal vein and real-time fluoroscopic images of the portal vein. Image fusion was used to guide the portal vein puncture during TIPS placement. At the end of the procedure, the interventional radiologists evaluated the utility of fusion imaging for portal vein puncture during TIPS placement. Mismatch between three-dimensional computed tomography angiography and real-time fluoroscopic images of the portal vein on image fusion was quantitatively analyzed. Posttreatment CT time, number of the puncture attempts, total radiation exposure and radiation from the retrograde portography were also recorded. Image fusion was considered useful for portal vein puncture in 13/18 TIPS procedures (72%). The mean posttreatment time to obtain fusion images was 16.4minutes. 3D volume rendered CT angiography images was strictly superimposed on direct portography in 10/18 procedures (56%). The mismatch mean value was 0.69cm in height and 0.28cm laterally. A mean number of 4.6 portal vein puncture attempts was made. Eight patients required less than three attempts. The mean radiation dose from retrograde portography was 421.2dGy.cm 2 , corresponding to a mean additional exposure of 19%. Fusion imaging resulting from image fusion from pre-procedural CT angiography is feasible, safe and makes portal puncture easier during TIPS placement. Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  19. Ureteroscopy-assisted Percutaneous Kidney Access Made Easy: First Clinical Experience with a Novel Navigation System Using Electromagnetic Guidance (IDEAL Stage 1).

    PubMed

    Lima, Estevao; Rodrigues, Pedro L; Mota, Paulo; Carvalho, Nuno; Dias, Emanuel; Correia-Pinto, Jorge; Autorino, Riccardo; Vilaça, João L

    2017-10-01

    Puncture of the renal collecting system represents a challenging step in percutaneous nephrolithotomy (PCNL). Limitations related to the use of standard fluoroscopic-based and ultrasound-based maneuvers have been recognized. To describe the technique and early clinical outcomes of a novel navigation system for percutaneous kidney access. This was a proof-of-concept study (IDEAL phase 1) conducted at a single academic center. Ten PCNL procedures were performed for patients with kidney stones. Flexible ureterorenoscopy was performed to determine the optimal renal calyx for access. An electromagnetic sensor was inserted through the working channel. Then the selected calyx was punctured with a needle with a sensor on the tip guided by real-time three-dimensional images observed on the monitor. The primary endpoints were the accuracy and clinical applicability of the system in clinical use. Secondary endpoints were the time to successful puncture, the number of attempts for successful puncture, and complications. Ten patients were enrolled in the study. The median age was 47.1 yr (30-63), median body mass index was 22.85kg/m 2 (19-28.3), and median stone size was 2.13cm (1.5-2.5cm). All stones were in the renal pelvis. The Guy's stone score was 1 in nine cases and 2 in one case. All 10 punctures of the collecting system were successfully completed at the first attempt without X-ray exposure. The median time to successful puncture starting from insertion of the needle was 20 s (range 15-35). No complications occurred. We describe the first clinical application of a novel navigation system using real-time electromagnetic sensors for percutaneous kidney access. This new technology overcomes the intrinsic limitations of traditional methods of kidney access, allowing safe, precise, fast, and effective puncture of the renal collecting system. We describe a new technology allowing safe and easy puncture of the kidney without radiation exposure. This could significantly facilitate one of the most challenging steps in percutaneous removal of kidney stones. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  20. Puncture Wounds: First Aid

    MedlinePlus

    ... aid/first-aid-puncture-wounds/basics/ART-20056665 . Mayo Clinic Footer Legal Conditions and Terms Any use of ... Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization and proceeds ...

  1. Simple method to set up low eccentricity initial data for moving puncture simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tichy, Wolfgang; Marronetti, Pedro

    2011-01-15

    We introduce two new eccentricity measures to analyze numerical simulations. Unlike earlier definitions these eccentricity measures do not involve any free parameters which makes them easy to use. We show how relatively inexpensive grid setups can be used to estimate the eccentricity during the early inspiral phase. Furthermore, we compare standard puncture data and post-Newtonian data in ADMTT gauge. We find that both use different coordinates. Thus low eccentricity initial momentum parameters for a certain separation measured in ADMTT coordinates are hard to use in puncture data, because it is not known how the separation in puncture coordinates is relatedmore » to the separation in ADMTT coordinates. As a remedy we provide a simple approach which allows us to iterate the momentum parameters until our numerical simulations result in acceptably low eccentricities.« less

  2. Protective materials with real-time puncture detection capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermes, R.E.; Stampfer, J.F.; Valdez-Boyle, L.S.

    1996-08-01

    The protection of workers from chemical, biological, or radiological hazards requires the use of protective materials that can maintain their integrity during use. An accidental puncture in the protective material can result in a significant exposure to the worker. A five ply material has been developed that incorporates two layers of an electrically conductive polymer sandwiched between three layers of a nonconductive polymer. A normally open circuit that is connected between the conductive layers will be closed by puncturing the material with either a conductive or nonconductive object. This can be used to activate an audible alarm or visual beaconmore » to warn the worker of a breach in the integrity of the material. The worker is not connected to the circuit, and the puncture can be detected in real-time, even when caused by a nonconductor.« less

  3. Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.

    PubMed

    Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia

    2008-10-01

    This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.

  4. Therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy on multiple renal calculi.

    PubMed

    Cui, Zhenyu; Gao, Yanjun; Yang, Wenzeng; Zhao, Chunli; Ma, Tao; Shi, Xiaoqiang

    2018-01-01

    To evaluate the therapeutic effects of visual standard channel combined with F4.8 visual puncture super-mini percutaneous nephrolithotomy (SMP) on multiple renal calculi. The clinical data of 46 patients with multiple renal calculi treated in Affiliated Hospital of Hebei University from October 2015 to September 2016 were retrospectively analyzed. There were 28 males and 18 females aged from 25 to 65 years old, with an average of 42.6. The stone diameters were 3.0-5.2 cm, (4.3 ± 0.8) cm on average. F4.8 visual puncture-assisted balloon expansion was used to establish a standard channel. After visible stones were removed through nephroscopy combined with ultrasound lithotripsy, the stones of other parts were treated through F4.8 visual puncture SMP with holmium laser. Indices such as the total time of channel establishment, surgical time, decreased value of hemoglobin, phase-I stone clearance rate and surgical complications were summarized. Single standard channel was successfully established in all cases with the assistance of F4.8 visual puncture, of whom 24 were combined with a single microchannel, 16 were combined with double microchannels, and six were combined with three microchannels. All patients were placed with nephrostomy tube which was not placed in the microchannels. Both F5 double J tubes were placed after surgery. The time for establishing a standard channel through F4.8 visual puncture was (6.8 ± 1.8) min, and that for establishing a single F4.8 visual puncture microchannel was (4.5 ± 0.9) min. The surgical time was (92 ± 15) min. The phase-I stone clearance rate was 91.3% (42/46), and the decreased value of hemoglobin was (12.21 ± 2.5) g/L. There were 8 cases of postoperative fever which was relieved after anti-inflammatory treatment. Four cases had 0.5-0.8 cm of stone residue in the lower calyx, and all stones were discharged one month after surgery by in vitro shock wave lithotripsy combined with position nephrolithotomy, without stone streets, delayed bleeding, peripheral organ damage or urethral injury. Combining visual standard channel with F4.8 visual puncture SMP for the treatment of multiple renal calculi had the advantages of reducing the number of large channels, high rate of stone clearance, safety and reliability and mild complications. The established F4.8 visual puncture channel was safer and more accurate.

  5. Development of Needle Insertion Manipulator for Central Venous Catheterization

    NASA Astrophysics Data System (ADS)

    Kobayashi, Yo; Hong, Jaesung; Hamano, Ryutaro; Hashizume, Makoto; Okada, Kaoru; Fujie, Masakatsu G.

    Central venous catheterization is a procedure, which a doctor insert a catheter into the patient’s vein for transfusion. Since there are risks of bleeding from arterial puncture or pneumothorax from pleural puncture. Physicians are strictly required to make needle reach up into the vein and to stop the needle in the middle of vein. We proposed a robot system for assisting the venous puncture, which can relieve the difficulties in conventional procedure, and the risks of complication. This paper reports the design structuring and experimental results of needle insertion manipulator. First, we investigated the relationship between insertion force and angle into the vein. The results indicated that the judgment of perforation using the reaction force is possible in case where the needling angle is from 10 to 20 degree. The experiment to evaluate accuracy of the robot also revealed that it has beyond 0.5 mm accuracy. We also evaluated the positioning accuracy in the ultrasound images. The results displays that the accuracy is beyond 1.0 mm and it has enough for venous puncture. We also carried out the venous puncture experiment to the phantom and confirm our manipulator realized to make needle reach up into the vein.

  6. Seamless data-range change using punctured convolutional codes for time-varying signal-to-noise ratios

    NASA Technical Reports Server (NTRS)

    Feria, Y.; Cheung, K.-M.

    1995-01-01

    In a time-varying signal-to-noise ration (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  7. Mycobacterium ulcerans low infectious dose and mechanical transmission support insect bites and puncturing injuries in the spread of Buruli ulcer.

    PubMed

    Wallace, John R; Mangas, Kirstie M; Porter, Jessica L; Marcsisin, Renee; Pidot, Sacha J; Howden, Brian; Omansen, Till F; Zeng, Weiguang; Axford, Jason K; Johnson, Paul D R; Stinear, Timothy P

    2017-04-01

    Addressing the transmission enigma of the neglected disease Buruli ulcer (BU) is a World Health Organization priority. In Australia, we have observed an association between mosquitoes harboring the causative agent, Mycobacterium ulcerans, and BU. Here we tested a contaminated skin model of BU transmission by dipping the tails from healthy mice in cultures of the causative agent, Mycobacterium ulcerans. Tails were exposed to mosquito (Aedes notoscriptus and Aedes aegypti) blood feeding or punctured with sterile needles. Two of 12 of mice with M. ulcerans contaminated tails exposed to feeding A. notoscriptus mosquitoes developed BU. There were no mice exposed to A. aegypti that developed BU. Eighty-eight percent of mice (21/24) subjected to contaminated tail needle puncture developed BU. Mouse tails coated only in bacteria did not develop disease. A median incubation time of 12 weeks, consistent with data from human infections, was noted. We then specifically tested the M. ulcerans infectious dose-50 (ID50) in this contaminated skin surface infection model with needle puncture and observed an ID50 of 2.6 colony-forming units. We have uncovered a biologically plausible mechanical transmission mode of BU via natural or anthropogenic skin punctures.

  8. Seamless Data-Rate Change Using Punctured Convolutional Codes for Time-Varying Signal-to-Noise Ratios

    NASA Astrophysics Data System (ADS)

    Feria, Y.; Cheung, K.-M.

    1994-10-01

    In a time-varying signal-to-noise ratio (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate-change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  9. Seamless data-range change using punctured convolutional codes for time-varying signal-to-noise ratios

    NASA Astrophysics Data System (ADS)

    Feria, Y.; Cheung, K.-M.

    1995-02-01

    In a time-varying signal-to-noise ration (SNR) environment, symbol rate is often changed to maximize data return. However, the symbol-rate change has some undesirable effects, such as changing the transmission bandwidth and perhaps causing the receiver symbol loop to lose lock temporarily, thus losing some data. In this article, we are proposing an alternate way of varying the data rate without changing the symbol rate and, therefore, the transmission bandwidth. The data rate change is achieved in a seamless fashion by puncturing the convolutionally encoded symbol stream to adapt to the changing SNR environment. We have also derived an exact expression to enumerate the number of distinct puncturing patterns. To demonstrate this seamless rate change capability, we searched for good puncturing patterns for the Galileo (14,1/4) convolutional code and changed the data rates by using the punctured codes to match the Galileo SNR profile of November 9, 1997. We show that this scheme reduces the symbol-rate changes from nine to two and provides a comparable data return in a day and a higher symbol SNR during most of the day.

  10. Construction of constant curvature punctured Riemann surfaces with particle-scattering interpretation

    NASA Astrophysics Data System (ADS)

    Bilal, Adel; Gervais, Jean-Loup

    A class of punctured constant curvature Riemann surfaces, with boundary conditions similar to those of the Poincaré half plane, is constructed. It is shown to describe the scattering of particle-like objects in two Euclidian dimensions. The associated time delays and classical phase shifts are introduced and connected to the behaviour of the surfaces at their punctures. For each such surface, we conjecture that the time delays are partial derivatives of the phase shift. This type of relationship, already known to be correct in other scattering problems, leads to a general integrability condition concerning the behaviour of the metric in the neighbourhood of the punctures. The time delays are explicitly computed for three punctures, and the conjecture is verified. The result, reexpressed as a product of Riemann zeta-functions, exhibits an intringuing number-theoretic structure: a p-adic product formula holds and one of Ramanujan's identities applies. An ansatz is given for the corresponding exact quantum S-matrix. It is such that the integrability condition is replaced by a finite difference relation only involving the exact spectrum already derived, in the associated Liouville field theory, by Gervais and Neveu.

  11. Laparoscopic Removal of a Large Ovarian Mass Utilizing Planned Trocar Puncture

    PubMed Central

    2012-01-01

    Background: Large cystic ovarian masses pose technical challenges to the laparoscopic surgeon. Removing large, potentially malignant specimens must be done with care to avoid the leakage of cyst fluid into the abdominal cavity. Case: We present the case of a large ovarian cystic mass treated laparoscopically with intentional trocar puncture of the mass to drain and remove the mass. Discussion: Large cystic ovarian masses can be removed laparoscopically with intentional trocar puncture of the mass to facilitate removal without leakage of cyst fluid. PMID:22906344

  12. Significant Improvement of Puncture Accuracy and Fluoroscopy Reduction in Percutaneous Transforaminal Endoscopic Discectomy With Novel Lumbar Location System: Preliminary Report of Prospective Hello Study.

    PubMed

    Fan, Guoxin; Guan, Xiaofei; Zhang, Hailong; Wu, Xinbo; Gu, Xin; Gu, Guangfei; Fan, Yunshan; He, Shisheng

    2015-12-01

    Prospective nonrandomized control study.The study aimed to investigate the implication of the HE's Lumbar LOcation (HELLO) system in improving the puncture accuracy and reducing fluoroscopy in percutaneous transforaminal endoscopic discectomy (PTED).Percutaneous transforaminal endoscopic discectomy is one of the most popular minimally invasive spine surgeries that heavily depend on repeated fluoroscopy. Increased fluoroscopy will induce higher radiation exposure to surgeons and patients. Accurate puncture in PTED can be achieved by accurate preoperative location and definite trajectory.The HELLO system mainly consists of self-made surface locator and puncture-assisted device. The surface locator was used to identify the exact puncture target and the puncture-assisted device was used to optimize the puncture trajectory. Patients who had single L4/5 or L5/S1 lumbar intervertebral disc herniation and underwent PTED were included the study. Patients receiving the HELLO system were assigned in Group A, and those taking conventional method were assigned in Group B. Study primary endpoint was puncture times and fluoroscopic times, and the secondary endpoint was location time and operation time.A total of 62 patients who received PTED were included in this study. The average age was 45.35 ± 8.70 years in Group A and 46.61 ± 7.84 years in Group B (P = 0.552). There were no significant differences in gender, body mass index, conservative time, and surgical segment between the 2 groups (P > 0.05). The puncture times were 1.19 ± 0.48 in Group A and 6.03 ± 1.87 in Group B (P < 0.001). The fluoroscopic times were 14.03 ± 2.54 in Group A and 25.19 ± 4.28 in Group B (P < 0.001). The preoperative location time was 4.67 ± 1.41 minutes in Group A and 6.98 ± 0.94 minutes in Group B (P < 0.001). The operation time was 79.42 ± 10.15 minutes in Group A and 89.65 ± 14.06 minutes in Group B (P = 0.002). The hospital stay was 2.77 ± 0.95 days in Group A and 2.87 ± 1.02 days in Group B (P = 0.702). There were no significant differences in the complication rate between the 2 groups (P = 0.386).The highlight of HELLO system is accurate preoperative location and definite trajectory. This preliminary report indicated that the HELLO system significantly improves the puncture accuracy of PTED and reduces the fluoroscopic times, preoperative location time, as well as operation time. (ChiCTR-ICR-15006730).

  13. Hollow mandrin facilitates external ventricular drainage placement.

    PubMed

    Heese, O; Regelsberger, J; Kehler, U; Westphal, M

    2005-07-01

    Placement of ventricular catheters is a routine procedure in neurosurgery. Ventricle puncture is done using a flexible ventricular catheter stabilised by a solid steel mandrin in order to improve stability during brain penetration. A correct catheter placement is confirmed after removing the solid steel mandrin by observation of cerebrospinal fluid (CSF) flow out of the flexible catheter. Incorrect placement makes further punctures necessary. The newly developed device allows CSF flow observation during the puncture procedure and in addition precise intracranial pressure (ICP) measurement. The developed mandrin is hollow with a blunt tip. On one side 4-5 small holes with a diameter of 0.8 mm are drilled corresponding exactly with the holes in the ventricular catheter, allowing CSF to pass into the hollow mandrin as soon as the ventricle is reached. By connecting a small translucent tube at the distal portion of the hollow mandrin ICP can be measured without loss of CSF. The system has been used in 15 patients with subarachnoid haemorrhage (SAH) or intraventricular haemeorrhage (IVH) and subsequent hydrocephalus. The new system improved the external ventricular drainage implantation procedure. In all 15 patients catheter placement was correct. ICP measurement was easy to perform immediately at ventricle puncture. In 4 patients at puncture no spontaneous CSF flow was observed, therefore by connecting a syringe and gentle aspiration of CSF correct placement was confirmed in this unexpected low pressure hydrocephalus. Otherwise by using the conventional technique further punctures would have been necessary. Advantages of the new technique are less puncture procedures with a lower risk of damage to neural structures and reduced risk of intracranial haemorrhages. Implantation of the ventricular catheter to far into the brain can be monitored and this complication can be overcome. Using the connected pressure monitoring tube an exact measurement of the opening intracranial pressure can be obtained performed without losing CSF.

  14. [Comparison of the intracranial pressure value in patients with hypertensive intracerebral hemorrhage treated with traditional craniotomy and puncture drainage].

    PubMed

    Song, Shao-jun; Fei, Zhou; Zhang, Xiang

    2003-09-01

    To compare the difference of intracranial pressure (ICP) in patients with hypertensive intracerebral hemorrhage (HICH) treated with two surgical procedures, traditional craniotomy and puncture drainage. One hundred and twelve cases with HICH were randomly divided into two groups. In one group, 60 patients were operated by traditional craniotomy and in another group, 52 cases by puncture drainage and urokinase treatment. In the meantime, ICP was monitored by placing catheter in lateral ventricle on the contralateral side of the hemorrhage. ICP values were recorded after operation at once, at 24 hours, 72 hours and 1 week. Although all the patients showed increased ICP, the increasing degree in patients treated with traditional craniotomy had lower ICP values (P<0.05 or P<0.01). Traditional craniotomy has advantages over puncture drainage for patients with HICH at least with respect to decreasing ICP.

  15. Complete prevention of blood loss with self-sealing haemostatic needles

    NASA Astrophysics Data System (ADS)

    Shin, Mikyung; Park, Sung-Gurl; Oh, Byung-Chang; Kim, Keumyeon; Jo, Seongyeon; Lee, Moon Sue; Oh, Seok Song; Hong, Seon-Hui; Shin, Eui-Cheol; Kim, Ki-Suk; Kang, Sun-Woong; Lee, Haeshin

    2017-01-01

    Bleeding is largely unavoidable following syringe needle puncture of biological tissues and, while inconvenient, this typically causes little or no harm in healthy individuals. However, there are certain circumstances where syringe injections can have more significant side effects, such as uncontrolled bleeding in those with haemophilia, coagulopathy, or the transmission of infectious diseases through contaminated blood. Herein, we present a haemostatic hypodermic needle able to prevent bleeding following tissue puncture. The surface of the needle is coated with partially crosslinked catechol-functionalized chitosan that undergoes a solid-to-gel phase transition in situ to seal punctured tissues. Testing the capabilities of these haemostatic needles, we report complete prevention of blood loss following intravenous and intramuscular injections in animal models, and 100% survival in haemophiliac mice following syringe puncture of the jugular vein. Such self-sealing haemostatic needles and adhesive coatings may therefore help to prevent complications associated with bleeding in more clinical settings.

  16. An evaluation of the Johnson-Cook model to simulate puncture of 7075 aluminum plates.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corona, Edmundo; Orient, George Edgar

    The objective of this project was to evaluate the use of the Johnson-Cook strength and failure models in an adiabatic finite element model to simulate the puncture of 7075- T651 aluminum plates that were studied as part of an ASC L2 milestone by Corona et al (2012). The Johnson-Cook model parameters were determined from material test data. The results show a marked improvement, in particular in the calculated threshold velocity between no puncture and puncture, over those obtained in 2012. The threshold velocity calculated using a baseline model is just 4% higher than the mean value determined from experiment, inmore » contrast to 60% in the 2012 predictions. Sensitivity studies showed that the threshold velocity predictions were improved by calibrating the relations between the equivalent plastic strain at failure and stress triaxiality, strain rate and temperature, as well as by the inclusion of adiabatic heating.« less

  17. Optical analysis of suspended particles in the cerebrospinal fluid obtained by puncture from patients diagnosed with the disorders of cerebrospinal fluid (CSF) circulation

    NASA Astrophysics Data System (ADS)

    Staroń, Waldemar; Herbowski, Leszek; Gurgul, Henryk

    2007-04-01

    The goal of the work was to determine the values of cumulative parameters of the cerebrospinal fluid. Values of the parameters characterise statistical cerebrospinal fluid obtained by puncture from the patients diagnosed due to suspicion of normotensive hydrocephalus. The cerebrospinal fluid taken by puncture for the routine examinations carried out at the patients suspected of normotensive hydrocephalus was analysed. In the paper there are presented results of examinations of several dozens of puncture samples of the cerebrospinal fluid coming from various patients. Each sample was examined under the microscope and photographed in 20 randomly chosen places. On the basis of analysis of the pictures showing the area of 100 x 100μm, the selected cumulative parameters such as count, numerical density, field area and field perimeter were determined for each sample. Then the average value of the parameters was determined as well.

  18. Surgical navigation in urology: European perspective.

    PubMed

    Rassweiler, Jens; Rassweiler, Marie-Claire; Müller, Michael; Kenngott, Hannes; Meinzer, Hans-Peter; Teber, Dogu

    2014-01-01

    Use of virtual reality to navigate open and endoscopic surgery has significantly evolved during the last decade. Current status of seven most interesting projects inside the European Association of Urology section of uro-technology is summarized with review of literature. Marker-based endoscopic tracking during laparoscopic radical prostatectomy using high-definition technology reduces positive margins. Marker-based endoscopic tracking during laparoscopic partial nephrectomy by mechanical overlay of three-dimensional-segmented virtual anatomy is helpful during planning of trocar placement and dissection of renal hilum. Marker-based, iPAD-assisted puncture of renal collecting system shows more benefit for trainees with reduction of radiation exposure. Three-dimensional laser-assisted puncture of renal collecting system using Uro-Dyna-CT realized in an ex-vivo model enables minimal radiation time. Electromagnetic tracking for puncture of renal collecting system using a sensor at the tip of ureteral catheter worked in an in-vivo model of porcine ureter and kidney. Attitude tracking for ultrasound-guided puncture of renal tumours by accelerometer reduces the puncture error from 4.7 to 1.8 mm. Feasibility of electromagnetic and optical tracking with the da Vinci telemanipulator was shown in vitro as well as using in-vivo model of oesophagectomy. Target registration error was 11.2 mm because of soft-tissue deformation. Intraoperative navigation is helpful during percutaneous puncture collecting system and biopsy of renal tumour using various tracking techniques. Early clinical studies demonstrate advantages of marker-based navigation during laparoscopic radical prostatectomy and partial nephrectomy. Combination of different tracking techniques may further improve this interesting addition to video-assisted surgery.

  19. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  20. Information computer program for laser therapy and laser puncture

    NASA Astrophysics Data System (ADS)

    Badovets, Nadegda N.; Medvedev, Andrei V.

    1995-03-01

    An informative computer program containing laser therapy and puncture methods has been developed. It was used successfully in connection with the compact Russian medical laser apparatus HELIOS-O1M in laser treatment and the education process.

  1. [Incidence of postmyelography syndrome and postmyelography complaints after lumbar puncture with the Sprotte pencil-like needle in comparison with the Quincke needle].

    PubMed

    Fox, R G; Reiche, W; Kiefer, M; Hagen, T; Huber, G

    1996-11-01

    Myelography in combination with a postmyelography CT is an important presurgical examination because of its excellent visualisation of the disc, the bone and the contrast-filled dura. Side effects after myelography can be observed in up to 50% of patients. The pathophysiological mechanism is thought to be increased cerebrospinal fluid leakage at the puncture site. Since the introduction by Sprotte in 1979 of the pencil-point needle, a modification of Whitacre's needle, fewer complaints after lumbar puncture have been reported. The aim of the study was to examine the influence of two types of needle points and the temperature (37 degrees C vs 21 degrees C) of the contrast medium (CM; iotrolan, Isovist) on the incidence of side effects of lumbar puncture for myelography. In a prospective randomized trial the incidence of complaints after lumbar puncture with intrathecal CM application was evaluated by the use of a 21-G pencil-point needle as modified by Sprotte compared to our usual 22-G needle with a Quincke bevel. Some 412 patients (201 female, 211 male; mean age 54.05 +/- 7.4 years) were investigated. Directly after examination and 1. 3 and 5 days later the patients were questioned about complaints (headache, neck stiffness nausea, vomiting, buzzing in the ear and dizziness). The results were tested by the chi square test. A significantly lower incidence of complaints was seen after lumbar puncture with the pencil-point needle/Quincke needle (headache: 6.3%/18.9%, P < 0.0001; headache lasting 3 days: 0.5%/7.8%, P < 0.0001; headache lasting 5 days: 0%/2.4%, P = 0.0305; nausea: 0%/4.9%, P = 0.0009; vomiting: 0%/3.4%, P = 0.0009; dizziness: 0%/3.4%, P = 0.0074; neck stiffness: 0%/3.4%, P = 0.0074). The temperature of the CM had no influence on the complaints. No influence was seen on the quality of the myelogram. No relation to sex and age was found. Complaints after lumbar puncture and myelography are caused by the cerebrospinal fluid leakage at the puncture site. The incidence of side effects related to this leakage can be reduced by using a pencil-point needle. The temperature of the CM has no influence on the complaints.

  2. Epidural blood patching for preventing and treating post-dural puncture headache.

    PubMed

    Sudlow, C; Warlow, C

    2002-01-01

    Dural puncture is a common procedure, but leakage of CSF from the resulting dural defect may cause postural headache after the procedure, and this can be disabling. Injecting an epidural blood patch around the site of the defect may stop this leakage, and so may have a role in preventing or treating post dural puncture headache. To assess the possible benefits and harms of epidural blood patching in both the prevention and the treatment of post-dural puncture headache. We searched the Cochrane Controlled Trials Register (Cochrane Library, Issue 4, 2000), MEDLINE (January 1994 to December 1998), and EMBASE (January 1980 to December 1998). We also searched the reference lists of relevant articles identified electronically, and asked both the authors of all included trials and colleagues with an interest in this area to let us know of any other potentially relevant studies not already identified. Date of last search: December 2000. We sought all properly randomised, unconfounded trials that compared epidural blood patch versus no epidural blood patch in the prevention or treatment of post-dural puncture headache among all types of patients undergoing dural puncture for any reason. The primary outcome of effectiveness was postural headache. One reviewer extracted details of trial methodology and outcome data from the reports of all trials considered eligible for inclusion. We invited the authors of all such trials both to check the information extracted and to provide any details that were unavailable in the published reports. Intention-to-treat analyses were performed using the Peto O-E method. Information about adverse effects (post-dural puncture backache, epidural infection and lower limb paraesthesia) was also extracted. Three trials (77 patients) were eligible for inclusion. Methodological details were generally incomplete. Although the results of our analyses suggested that both prophylactic and therapeutic epidural blood patching may be of benefit, the very small numbers of patients and outcome events, as well as uncertainties about trial methodology, precluded reliable assessments of the potential benefits and harms of this intervention. Further, adequately powered, randomised trials (including at least a few hundred patients) are required before reliable conclusions can be drawn about the role of epidural blood patching in the prevention and treatment of post-dural puncture headache.

  3. Intrathecal Baclofen Therapy in a Child With Severe Scoliosis: Report of 2 Cases.

    PubMed

    Sasaki, Natsu; Ogiwara, Hideki

    2016-08-01

    Scoliosis is commonly found in children with cerebral palsy. Many patients with cerebral palsy and scoliosis undergo intrathecal baclofen (ITB) pump placement. The authors report 2 cases with cerebral palsy and severe scoliosis treated with intrathecal baclofen. The case of a 7-year-old boy with shunted hydrocephalus required surgical revision of the intrathecal catheter, while the other patient without shunt did not require revision. In the patient with shunted hydrocephalus, after the initial placement of baclofen pump and catheter at Th3 level, spasticity of lower extremities did not improve. The Indium(111) diethylenetriamine pentaacetic acid (In(111) DTPA) scintigraphy with injection of In(111) DTPA through the pump did not demonstrate distribution of the tracer to the lumbosacral area. Conversely, by direct injection of In(111) DTPA through lumbar puncture, the tracer distributed in the whole spinal canal. Replacement of the tip of the catheter caudal to the curve of the scoliosis improved the symptom. The authors suggest that, in patients with severe scoliosis and shunted hydrocephalus, it may be necessary to place the tip of the catheter caudal to the curve of the scoliosis for correction of spasticity of lower extremities. © 2016 International Neuromodulation Society.

  4. Primary Intramedullary Malignant Lymphoma in the Cervical Cord with a Presyrinx State

    PubMed Central

    Sugawara, Atsushi; Koji, Takahiro; Beppu, Takaaki; Mue, Yoshiharu; Sugai, Tamotsu; Ogasawara, Knuaki

    2017-01-01

    A 79-year-old man presented with primary intramedullary malignant lymphoma with a presyrinx state in the cervical cord manifesting as left hemiparesis and hemidysesthesia. The magnetic resonance imaging (MRI) scan showed an intramedullary mass in the cervical spinal cord at the level of C1 and T2-weighted image prolongation from the medulla to the level of C5. According to the progression of hemiparesis, he underwent an emergency removal of the tumor under general anesthesia. The tumor was totally removed, and the peritumoral signal abnormality was not present in the postoperative MRI. Histological examination revealed diffuse large B cell lymphoma. While brain MRI, bone marrow puncture, and 18F-fluorodeoxy-glucose positron emission tomography (18FDG-PET) of the whole body were performed to find out a primary lesion, there were no abnormalities. He underwent a high-dose methotrexate-based chemotherapy and a local irradiation therapy (40Gy). He has been alive for more than two years since the symptom onset, and without any evidence of recurrence. This case suggests that malignant lymphoma, as an infiltrating and rapidly progressive tumor, may be accompanied by syrinx. PMID:29507854

  5. Unexpected rare complication of the facial paralysis in a patient with an antrochoanal polyp following canine fossa puncture.

    PubMed

    Kim, Ah-Young; Choi, Myoung Su

    2015-05-14

    Canine fossa puncture (CFP) combined with endoscopic sinus surgery is a simple and effective method for treating antrochoanal polyps, particularly those that originate in the anterior, inferior or medial aspect of the antrum. Several complications can occur following CFP, including facial paraesthesia and dental numbness. However, facial palsy is extremely rare after CFP. We postulated that a possible mechanism of facial palsy is pressure injury to the soft tissues adjacent to the puncture site, which can damage the buccal branch of the facial nerve during CFP. 2015 BMJ Publishing Group Ltd.

  6. Successful treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV without arterial puncture: the transvenous triple-overlay embolization (TAILOREd) technique.

    PubMed

    Huynh, Thien J; Morton, Ryan P; Levitt, Michael R; Ghodke, Basavaraj V; Wink, Onno; Hallam, Danial K

    2017-08-18

    We report successful transvenous treatment of direct carotid-cavernous fistula in a patient with Ehlers-Danlos syndrome type IV using a novel triple-overlay embolization (TAILOREd) technique without the need for arterial puncture, which is known to be highly risky in this patient group. The TAILOREd technique allowed for successful treatment using preoperative MR angiography as a three-dimensional overlay roadmap combined with cone beam CT and live fluoroscopy, precluding the need for an arterial puncture. 2017 BMJ Publishing Group Ltd.

  7. Effect of system compliance on crack nucleation in soft materials

    NASA Astrophysics Data System (ADS)

    Rattan, Shruti; Crosby, Alfred

    Puncture mechanics in soft materials is critical for the development of new surgical instruments, robot assisted-surgery as well as new materials used in personal protective equipment. However, analytical techniques to study this important deformation process are limited. We have previously described a simple experimental method to study the resistive forces and failure of a soft gel being indented with a small tip needle. We showed that puncture stresses can reach two orders of magnitude greater than the material modulus and that the force response is insensitive to the geometry of the indenter at large indentation depths. Currently, we are examining the influence of system compliance on crack nucleation (e.g. puncture) in soft gels. It is well known that system compliance influences the peak force in adhesion and traditional fracture experiments; however, its influence on crack nucleation is unresolved. We find that as the system becomes more compliant, lower peak forces required to puncture a gel of certain stiffness with the same indenter were measured. We are developing scaling relationships to relate the peak puncture force and system compliance. Our findings introduce new questions with regard to the possibility of intrinsic materials properties related to the critical stress and energy for crack nucleation in soft materials.

  8. On Railroad Tank Car Puncture Performance: Part II - Estimating Metrics

    DOT National Transportation Integrated Search

    2016-04-12

    This paper is the second in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perfor...

  9. On Railroad Tank Car Puncture Performance: Part I - Considering Metrics

    DOT National Transportation Integrated Search

    2016-04-12

    This paper is the first in a two-part series on the puncture performance of railroad tank cars carrying hazardous materials in the event of an accident. Various metrics are often mentioned in the open literature to characterize the structural perform...

  10. Detailed puncture analyses tank cars : analysis of different impactor threats and impact conditions.

    DOT National Transportation Integrated Search

    2013-03-01

    There has been significant research in recent years to analyze and improve the impact behavior and puncture resistance of railroad tank cars. Much of this research has been performed using detailed nonlinear finite element analyses supported by full ...

  11. [Special cannulas for the puncture of implanted catheter port systems].

    PubMed

    Haindl, H; Müller, H

    1989-04-01

    The Huber-Point cannula is generally recommended for portal puncture. Two comparative studies are published that show no advantage in using Huber-point cannulas. This has been verified by technical investigations. A new type of non-coring cannula is described.

  12. New EU ETS Phase 4 rules temporarily puncture waterbed

    NASA Astrophysics Data System (ADS)

    Perino, Grischa

    2018-04-01

    The new rules of the EU ETS will fundamentally change its character. The long-term cap on emissions will become a function of past and future market outcomes, temporarily puncturing the waterbed and having retroactive impacts on GHG abatement from overlapping policies.

  13. The aeromedical assessment of human systolic and diastolic blood-pressure transients without direct arterial puncture.

    DOT National Transportation Integrated Search

    1966-05-01

    A system for virtually continuous measurement of both systolic and diatolic blood pressures without recourse to direct arterial puncture has been effected by the modification of already existing standard equipment. This system entails the measurement...

  14. Microneedle arrays allow lower microbial penetration than hypodermic needles in vitro.

    PubMed

    Donnelly, Ryan F; Singh, Thakur Raghu Raj; Tunney, Michael M; Morrow, Desmond I J; McCarron, Paul A; O'Mahony, Conor; Woolfson, A David

    2009-11-01

    In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. When employing Silescol membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol membranes in the corresponding experiments. Approximately 10(3) cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle-punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse.

  15. Assessment of Injuries Caused by Anastrepha fraterculus (Wied.) (Diptera: Tephritidae) on the Incidence of Bunch Rot Diseases in Table Grape.

    PubMed

    Machota, R; Bortoli, L C; Cavalcanti, F R; Botton, M; Grützmacher, A D

    2016-08-01

    Anastrepha fraterculus (Wied.) is the main insect pest of table grapes (Vitis vinifera) in the Southern Region of Brazil. In this study, we aimed to investigate the effect of fruit puncturing by adult females and larval infestation by A. fraterculus on the occurrence of bunch rot disease in the grape (cultivar "Itália") by evaluating grapes (a) punctured for oviposition by females of A. fraterculus, sterilized in laboratory with novaluron (40 mg L(-1)) and further spray-inoculated separately with Botrytis cinerea (1 × 10(6) conidia mL(-1)), Glomerella cingulata (1 × 10(6) conidia mL(-1)), and bacteria and yeast that cause sour rot (1 × 10(5) cells mL(-1)), (b) grapes punctured for oviposition by non-sterilized females with pathogen spraying, (c) grapes with mechanical wounds and pathogen spraying, (d) grapes with no wounds and with pathogen spraying, (e) grapes punctured for oviposition by A. fraterculus chemically sterilized in laboratory with novaluron, (f) grapes punctured for oviposition by A. fraterculus non-sterilized in laboratory with novaluron, (g) grapes with mechanical wounds, and (h) grapes with no sterilization or pathogen spraying. Our data indicated that the mechanical and oviposition wounds caused by A. fraterculus increased the percentage of grapes infected by B. cinerea, G. cingulata, and microorganisms of acid rot. The grape puncturing by A. fraterculus and the mechanical wound allows the penetration of B. cinerea and microorganisms leading to acid rot. We conclude that the fruit fly A. fraterculus may facilitate phytopathogens penetration leading to bunch rots in the table grape Itália.

  16. Puncture mechanics of cnidarian cnidocysts: a natural actuator

    PubMed Central

    Oppegard, Shawn C; Anderson, Peter A; Eddington, David T

    2009-01-01

    Background Cnidocysts isolated from cnidarian organisms are attractive as a drug-delivery platform due to their fast, efficient delivery of toxins. The cnidocyst could be utilized as the means to deliver therapeutics in a wearable drug-delivery patch. Cnidocysts have been previously shown to discharge upon stimulation via electrical, mechanical, and chemical pathways. Cnidocysts isolated from the Portuguese Man O' War jellyfish (Physalia physalis) are attractive for this purpose because they possess relatively long threads, are capable of puncturing through hard fish scales, and are stable for years. Results As a first step in using cnidocysts as a functional component of a drug delivery system, the puncture mechanics of the thread were characterized. Tentacle-contained cnidocysts were used as a best-case scenario due to physical immobilization of the cnidocysts within the tentacle. Ex vivo tentacle-contained cnidocysts from Physalia possessed an elastic modulus puncture threshold of approximately 1-2 MPa, based on puncture tests of materials with a gamut of hardness. Also, a method for inducing discharge of isolated cnidocysts was found, utilizing water as the stimulant. Preliminary lectin-binding experiments were performed using fluorophore-conjugated lectins as a possible means to immobilize the isolated cnidocyst capsule, and prevent reorientation upon triggering. Lectins bound homogeneously to the surface of the capsule, suggesting the lectins could be used for cnidocyst immobilization but not orientation. Conclusion Cnidocysts were found to puncture materials up to 1 MPa in hardness, can be discharged in a dry state using water as a stimulant, and bind homogeneously to lectins, a potential means of immobilization. The information gained from this preliminary work will aid in determining the materials and design of the patch that could be used for drug delivery. PMID:19785761

  17. Relationships of abscised cotton fruit to boll weevil (Coleoptera: Curculionidae) feeding, oviposition, and development.

    PubMed

    Showler, Allan T

    2008-02-01

    Abscised cotton, Gossypium hirsutum L., fruit in field plots planted at different times were examined to assess adult boll weevil, Anthonomus grandis grandis Boheman (Coleoptera: Curculionidae), use of squares and bolls during 2002 and 2003 in the Lower Rio Grande Valley of Texas. Although boll abscission is not necessarily related to infestation, generally more bolls abscised than squares and abundances of fallen bolls were not related to the planting date treatments. During 2003, fallen squares were most abundant in the late-planted treatment. Although large squares (5.5-8-mm-diameter) on the plant are preferred for boll weevil oviposition, diameter of abscised squares is not a reliable measurement because of shrinkage resulting from desiccation and larval feeding. Fallen feeding-punctured squares and bolls were most abundant in late plantings but differences between fallen feeding-punctured squares versus fallen feeding-punctured bolls were found in only one treatment in 2003. During the same year, fallen oviposition-punctured squares were more numerous in the late-planted treatment than in the earlier treatments. Treatment effects were not found on numbers of oviposition-punctured bolls, but fallen oviposition-punctured squares were more common than bolls in the late-planted treatment compared with earlier treatments each year. Dead weevil eggs, larvae, and pupae inside fallen fruit were few and planting date treatment effects were not detected. Living third instars and pupae were more abundant in fallen squares of the late-planted treatment than in the earlier treatments and bolls of all three treatments. This study shows that fallen squares in late-planted cotton contribute more to adult boll weevil populations than bolls, or squares of earlier plantings.

  18. Contrast enhanced computed tomography and reconstruction of hepatic vascular system for transjugular intrahepatic portal systemic shunt puncture path planning.

    PubMed

    Qin, Jian-Ping; Tang, Shan-Hong; Jiang, Ming-De; He, Qian-Wen; Chen, Hong-Bin; Yao, Xin; Zeng, Wei-Zheng; Gu, Ming

    2015-08-28

    To describe a method for the transjugular intrahepatic portal systemic shunt (TIPS) placement performed with the aid of contrast-enhanced computed tomography (CECT) and three-dimensional reconstructed vascular images (3D RVIs), and to assess its safety and effectiveness. Four hundred and ninety patients were treated with TIPS between January 2005 and December 2012. All patients underwent liver CECT and reconstruction of 3D RVIs of the right hepatic vein to portal vein (PV) prior to the operation. The 3D RVIs were carefully reviewed to plan the puncture path from the start to target points for needle pass through the PV in the TIPS procedure. The improved TIPS procedure was successful in 483 (98.6%) of the 490 patients. The number of punctures attempted was one in 294 (60%) patients, 2 to 3 in 147 (30%) patients, 4 to 6 in 25 (5.1%) patients and more than 6 in 17 (3.5%) patients. Seven patients failed. Of the 490 patients, 12 had punctures into the artery, 15 into the bile duct, eight into the gallbladder, and 18 through the liver capsule. Analysis of the portograms from the 483 successful cases indicated that the puncture points were all located distally to the PV bifurcation on anteroposterior images, while the points were located proximally to the bifurcation in the three cases with intraabdominal bleeding. The complications included three cases of bleeding, of whom one died and two needed surgery. Use of CECT and 3D RVIs to plan the puncture path for TIPS procedure is safe, simple and effective for clinical use.

  19. Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui

    2014-08-01

    SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.

  20. [The influence of lumbar sympathetic ganglion radiofrequency thermocoagulation on the activation of microglia in rats with diabetic neuropathic pain].

    PubMed

    Zhang, J H; Yang, C X; Zhong, J Y; Zhang, L; Xiong, Q M; Wang, J; Wang, H B

    2016-06-28

    To observe the influence of lumbar sympathetic ganglion radiofrequency thermocoagulation on the activation of spinal microglia in rats with diabetic neuropathic pain (DNP). Thirty-six painful diabetic Sprague-Dawley rats induced by 60 mg/kg streptozotocin (STZ) intraperitoneal injection were randomly divided into diabetic neuropathic pain group (group DNP, n=12), Sham operation group (group Sham, n=12) and radiofrequency thermocoagulation group (group R, n=12). Meanwhile another 12 age-matched rats were allocated as normal control group (group N), rats in group N received intraperitoneal injection of equal volume of normal saline. Twenty-eight days after STZ injection, rats in group R received L3 lumbar sympathetic ganglia radiofrequency thermocoagulation on the left side under X-ray guideline after anesthesia with damage time 60 s and damage temperature 60 ℃. Rats in group Sham received puncture positioning, but not thermocoagulation therapy. The mechanical paw withdrawal threshold (PWT) were performed before STZ injection, 7, 14, 21, 28 days after STZ injection and 1, 3, 5, 7, 14 days after radiofrequency thermocoagulation, respectively. Blood glucose were performed before STZ injection, 3, 28 days after STZ injection and 1, 14days after radiofrequency thermocoagulation. After the final behavioral testing, L3-L5 spinal cord tissues were removed to exam the expression of microglia marker OX42 by Western blotting and immunofluorescence technique, and the changes in the expression of inflammation factor IL-1β, IL-6, TNF-α were detected by ELISA technique. Compared with group N, after 14, 21, 28 days of STZ injection and 1, 3, 5, 7, 14 days of radiofrequency thermocoagulation, the PWT of group DNP and group Sham decreased significantly (P<0.05); Before radiofrequency thermocoagulation, the PWT of rats in group DNP was (3.84±0.83) g, the PWT of rats in group R was (4.45±0.88) g, there was no statistically significant difference between group DNP and group R (t=1.514, P>0.05), but after radiofrequency thermocoagulation, compared with DNP group, the PWT of rats in group R increased significantly (P<0.05), and lasted to 14 d after radiofrequency thermocoagulation. The ratio of spinal microglia marker OX42 and GAPDH, the expression of inflammation factor IL-1β, IL-6, and TNF-α in group N were 0.074±0.023, (35.93±6.16) pg/ml, (92.11±13.23) pg/ml, and (169.50±22.64) pg/ml, respectively. The ratio of spinal microglia marker OX42 and GAPDH, the expression of inflammation factor IL-1β, IL-6, and TNF-α in group DNP were 1.023±0.185, (73.82±9.25) pg/ml, (155.33±21.82) pg/ml, and (298.30±33.21) pg/ml, respectively. The ratio of spinal microglia marker OX42 and GAPDH, the expression of inflammation factor IL-1β, IL-6, and TNF-α in group Sham were 0.951±0.103, (73.00±7.54) pg/ml, (151.02±24.26) pg/ml, and (294.01±36.37) pg/ml, respectively. The ratio of spinal microglia marker OX42 and GAPDH, the expression of inflammation factor IL-1β, IL-6, and TNF-α in group R were 0.563±0.019, (51.81±7.36) pg/ml, (123.24±16.13) pg/ml, and (229.23±29.16) pg/ml, respectively. Compared with group N, the expression of spinal microglia marker OX42 and inflammation factor IL-1β, IL-6, and TNF-α in group DNP, group Sham and group R increased significantly (F=7.501, 348.698, 568.021, 145.110, all P<0.05). Compared with DNP group, the expression of spinal microglia marker OX42 and inflammation factor IL-1β, IL-6, and TNF-α of group R reduced significantly (all P<0.05). The lumbar sympathetic ganglion radiofrequency thermocoagulation can alleviate diabetic neuropathic pain. The mechanism may relate with the inhibition of spinal microglia activation and the lower expression of inflammation factor.

  1. Chlorine tank car puncture resistance evaluation

    DOT National Transportation Integrated Search

    1992-07-01

    Experimental studies have been conducted to evaluate the relative puncture resistance of DOT 105A500W (chlorine) tank cars and DOT 112J340W (propane) tank cars equipped with 1/2-inch steel head shields. These studies included a series of full- and 1/...

  2. Puncture Self-Healing Polymers for Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Penner, Ronald K.; Bogert, Phil B.; Yost, W. T.; Siochi, Emilie J.

    2011-01-01

    Space exploration launch costs on the order of $10K per pound provide ample incentive to seek innovative, cost-effective ways to reduce structural mass without sacrificing safety and reliability. Damage-tolerant structural systems can provide a route to avoiding weight penalty while enhancing vehicle safety and reliability. Self-healing polymers capable of spontaneous puncture repair show great promise to mitigate potentially catastrophic damage from events such as micrometeoroid penetration. Effective self-repair requires these materials to heal instantaneously following projectile penetration while retaining structural integrity. Poly(ethylene-co-methacrylic acid) (EMMA), also known as Surlyn is an ionomer-based copolymer that undergoes puncture reversal (self-healing) following high impact puncture at high velocities. However EMMA is not a structural engineering polymer, and will not meet the demands of aerospace applications requiring self-healing engineering materials. Current efforts to identify candidate self-healing polymer materials for structural engineering systems are reported. Rheology, high speed thermography, and high speed video for self-healing semi-crystalline and amorphous polymers will be reported.

  3. [Ethyl chloride aerosol spray for local anesthesia before arterial puncture: randomized placebo-controlled trial].

    PubMed

    Ballesteros-Peña, Sendoa; Fernández-Aedo, Irrintzi; Vallejo-De la Hoz, Gorka

    2017-06-01

    To compare the efficacy of an ethyl chloride aerosol spray to a placebo spray applied in the emergency department to the skin to reduce pain from arterial puncture for blood gas analysis. Single-blind, randomized placebo-controlled trial in an emergency department of Hospital de Basurto in Bilbao, Spain. We included 126 patients for whom arterial blood gas analysis had been ordered. They were randomly assigned to receive application of the experimental ethyl chloride spray (n=66) or a placebo aerosol spray of a solution of alcohol in water (n=60). The assigned spray was applied just before arterial puncture. The main outcome variable was pain intensity reported on an 11-point numeric rating scale. The median (interquartile range) pain level was 2 (1-5) in the experimental arm and 2 (1-4.5) in the placebo arm (P=.72). Topical application of an ethyl chloride spray did not reduce pain caused by arterial puncture.

  4. Ghrelin inhibits proinflammatory responses and prevents cognitive impairment in septic rats.

    PubMed

    Wei, Hua; Cao, Xiaohua; Zeng, Qingwen; Zhang, Fujun; Xue, Qingsheng; Luo, Yan; Lee, Jae-Woo; Yu, Buwei; Feng, Xiaomei

    2015-05-01

    A novel stomach-derived peptide, ghrelin, is down-regulated in sepsis and its IV administration decreases proinflammatory cytokines and mitigates organ injury. In this study, we wanted to investigate the effects of ghrelin on proinflammatory responses and cognitive impairment in septic rats. Prospective, randomized, controlled experiment. Animal basic science laboratory. Sprague-Dawley rats, weighing 250-300 g. Sepsis was induced by cecal ligation and puncture. Animals were randomly divided into four groups: sham, sham + ghrelin, cecal ligation and puncture, and cecal ligation and puncture + ghrelin. Saline was given subcutaneously (30 mL/kg) at 4 and 16 hours after surgery for all rats. Septic rats were treated with ceftriaxone (30 mg/kg) and clindamycin (25 mg/kg) subcutaneously at 4 and 16 hours after surgery. Ghrelin (80 μg/kg) was administrated intraperitoneally 4 and 16 hours after surgery in sham + ghrelin group and cecal ligation and puncture + ghrelin group. The levels of proinflammatory cytokines in hippocampus were measured by enzyme-linked immunosorbent assay, and cleaved caspase-3 was detected by Western blot 24 hours after surgery. Neuronal apoptosis was determined by terminal deoxynucleotidyl transferase dUTP nick-end labeling staining 48 hours after surgery. Additional animals were monitored to record survival and body weight changes for 10 days after surgery. Survival animals underwent behavioral tasks 10 days after surgery: open-field, novel object recognition, and continuous multiple-trial step-down inhibitory avoidance task. Ghrelin significantly decreased the levels of proinflammatory cytokines and inhibited the activation of caspase-3 in the hippocampus after cecal ligation and puncture. The density of terminal deoxynucleotidyl transferase dUTP nick-end labeling-positive apoptotic neurons was significantly lowered by ghrelin. In addition, ghrelin improved the survival rates after cecal ligation and puncture. There were no differences in the distance and move time between groups in open-field task. However, the survivors after cecal ligation and puncture were unable to recognize the novel object and required more training trials to reach the acquisition criterion. All these long-term impairments were prevented by ghrelin. Ghrelin inhibited proinflammatory responses, improved the survival rate, and prevented cognitive impairment in septic rats.

  5. Successful use of nitrous oxide during lumbar punctures: A call for nitrous oxide in pediatric oncology clinics.

    PubMed

    Livingston, Mylynda; Lawell, Miranda; McAllister, Nancy

    2017-11-01

    Numerous reports describe the successful use of nitrous oxide for analgesia in children undergoing painful procedures. Although shown to be safe, effective, and economical, nitrous oxide use is not yet common in pediatric oncology clinics and few reports detail its effectiveness for children undergoing repeated lumbar punctures. We developed a nitrous oxide clinic, and undertook a review of pediatric oncology lumbar puncture records for those patients receiving nitrous oxide in 2011. No major complications were noted. Minor complications were noted in 2% of the procedures. We offer guidelines for establishing such a clinic. © 2017 Wiley Periodicals, Inc.

  6. A preliminary study on puncture resistances of top and bottom layers of multi-layered needlepunched nonwoven geotextiles

    NASA Astrophysics Data System (ADS)

    Alan, G.; Tercan, M.

    2017-10-01

    Needlepunched nonwoven textiles are commonly used as geotextiles for various applications. Considering both environmental and economical benefits, utilization of recycled fibres in nonwoven geotextiles has become an attractive issue. Within this scope, the aim of this study is to evaluate the puncture resistance performances of top and bottom layers of multi-layered needle punched nonwovens made of recycled fibres to be used as membrane protective geotextiles by comparing them with those of made from polypropylene and polyester fibres. Puncture resistance results indicated that nonwovens made of recycled fibres demonstrated good performances at this preliminary stage.

  7. Λ scattering equations

    NASA Astrophysics Data System (ADS)

    Gomez, Humberto

    2016-06-01

    The CHY representation of scattering amplitudes is based on integrals over the moduli space of a punctured sphere. We replace the punctured sphere by a double-cover version. The resulting scattering equations depend on a parameter Λ controlling the opening of a branch cut. The new representation of scattering amplitudes possesses an enhanced redundancy which can be used to fix, modulo branches, the location of four punctures while promoting Λ to a variable. Via residue theorems we show how CHY formulas break up into sums of products of smaller (off-shell) ones times a propagator. This leads to a powerful way of evaluating CHY integrals of generic rational functions, which we call the Λ algorithm.

  8. Interventional Management of Massive Hemothorax Due to Inadvertent Puncture of an Aberrant Right Subclavian Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jahnke, Thomas, E-mail: thomas.jahnke@gmx.net; Schaefer, Phillip Jost; Heller, Martin

    2008-07-15

    We report a case of massive hemothorax due to inadvertent puncture of an aberrant right subclavian artery during central venous access. Iatrogenic laceration at the origin of the right internal thoracic artery was successfully treated with coil embolization of the internal thoracic artery followed by stent-graft placement into the subclavian artery. Due to its elongated and abnormal course, an aberrant right subclavian artery may predispose to inadvertent puncture during vein catheterization and should be recognized as a potential threat for such procedures. Our case emphasizes that ultrasound guidance should be used routinely for central venous lines wherever possible.

  9. Low complexity Reed-Solomon-based low-density parity-check design for software defined optical transmission system based on adaptive puncturing decoding algorithm

    NASA Astrophysics Data System (ADS)

    Pan, Xiaolong; Liu, Bo; Zheng, Jianglong; Tian, Qinghua

    2016-08-01

    We propose and demonstrate a low complexity Reed-Solomon-based low-density parity-check (RS-LDPC) code with adaptive puncturing decoding algorithm for elastic optical transmission system. Partial received codes and the relevant column in parity-check matrix can be punctured to reduce the calculation complexity by adaptive parity-check matrix during decoding process. The results show that the complexity of the proposed decoding algorithm is reduced by 30% compared with the regular RS-LDPC system. The optimized code rate of the RS-LDPC code can be obtained after five times iteration.

  10. Modification of one man life raft

    NASA Technical Reports Server (NTRS)

    Soter, E. J. (Inventor)

    1974-01-01

    A one man inflatable life raft is described. The raft has an inflatable tube perimetrically bounding the occupant receiving space with a flexible floor member. A zippered opening in the floor allows entry and facilitates the use of a constant diameter tube. An airtight fabric bulkhead divides the peripheral tube longitudinally into inflatable tube sections, where if either tube section were punctured, the bulkhead would move into the punctured section to substitute for the punctured wall portion and maintain the inflatable volume of the tube. The floor member is attached to the central portion of the tube wall so that either side of the raft can be the up side.

  11. A Proposed Maneuver to Guide Transseptal Puncture Using Real-Time Three-Dimensional Transesophageal Echocardiography: Pilot Study.

    PubMed

    Mahmoud, Hani M; Al-Ghamdi, Mohammed A; Ghabashi, Abdullah E; Anwar, Ashraf M

    2015-01-01

    Aim of Study. To assess the feasibility of a new proposed maneuver "RATLe-90" using real-time three-dimensional transesophageal echocardiography (RT-3DTEE) for anatomically oriented visualization of the interatrial septum (IAS) in guiding the transseptal puncture TSP. Methods. The study included 20 patients (mean age, 60.2 ± 6.7 years; 60% males) who underwent TSP for different indications. RT-3DTEE was used to guide TSP. The proposed maneuver RATLe-90 (Rotate-Anticlockwise-Tilt-Left-90) was applied in all cases to have the anatomically oriented en face view of the IAS from the right atrial (RA) aspect. Having this anatomically oriented view, we guided the TSP catheter towards the proper puncture site according to the planned procedure. Results. Using the RATLe-90 maneuver, the anatomically oriented en face view of the IAS from the RA was obtained in all patients. We were able to guide the puncture catheter to the proper puncture site on the IAS. The 3D images obtained were clearly understood by both echocardiographers and interventionists. The RATLe-90 maneuver acquisition time was 19.9 ± 1.6 seconds. The time-to-tent was 64.8 ± 16.3 seconds. Less TEE probe manipulations were needed while guiding the TSP. Conclusions. Application of RT3D-TEE during TSP using RATLe-90 maneuver is feasible with shorter fluoroscopy time and minimizing TEE probe manipulations.

  12. Secondary tracheoesophageal puncture in-office using Seldinger technique.

    PubMed

    Britt, Christopher J; Lippert, Dylan; Kammer, Rachael; Ford, Charles N; Dailey, Seth H; McCulloch, Timothy; Hartig, Gregory

    2014-05-01

    Evaluate the safety and efficacy of in-office secondary tracheoesophageal puncture (TEP) technique using transnasal esophagoscopy (TNE) and the Seldinger technique in conjunction with a cricothyroidotomy kit for placement. Case series with chart review. Academic medical center. A retrospective chart review was performed on 83 subjects who underwent in-office secondary TEP. Variables that were examined included disease site, staging, histologic diagnosis, extent of resection and reconstruction, chemoradiation, functional voice status (as assessed by speech pathologist in most recent note), and complications directly related to the procedure. Eighty-three individuals from our institution met our criteria for in-office secondary TEP from 2005 to August 2012. Of these, 97.6% (81/83) had no complications of TEP. The overall complication rate was 2.4% (2/83). Complications included bleeding from puncture site and closure of puncture site after dislodgement of prosthesis at the time of puncture. Fluent conversational speech was achieved in 69.9% of all patients (58/83), and an additional 19.3% (16/83) achieved functional/intelligible speech; of those, 3.6% (3/83) were unable to achieve fluent conversational speech due to anatomic defects from previous surgery. An in-office TEP can be safely performed using the Seldinger technique with direct visualization using TNE, despite the extent of resection or reconstruction, with functional speech outcomes comparable to other studies available in the literature.

  13. A Video Transmission System for Severely Degraded Channels

    DTIC Science & Technology

    2006-07-01

    rate compatible punctured convolutional codes (RCPC) . By separating the SPIHT bitstream...June 2000. 149 [170] J. Hagenauer, Rate - compatible punctured convolutional codes (RCPC codes ) and their applications, IEEE Transactions on...Farvardin [160] used rate compatible convolutional codes . They noticed that for some transmission rates , one of their EEP schemes, which may

  14. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... performance test. 2. Carbon adsorber (regenerative) to which puncture sealant application spray booth emissions are ducted a. Maintain the total regeneration mass, volumetric flow, and carbon bed temperature at the operating range established during the performance test.b. Reestablish the carbon bed temperature...

  15. 78 FR 52407 - Airworthiness Directives; Eurocopter France Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... the flotation gear. (A) Unfold and visually inspect the float assemblies for any cuts, tears... inflating valve and inspect the fabric panels and girts for any cuts, tears, punctures, or abrasion. If there is a cut, tear, puncture, or any abrasion, repair the float. (2) For emergency floatation gear...

  16. 49 CFR 179.16 - Tank-head puncture-resistance systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... CARS General Design Requirements § 179.16 Tank-head puncture-resistance systems. (a) Performance...; and (3) The impacted tank car is pressurized to at least 6.9 Bar (100 psig). (b) Verification by... design and test requirements of the full-head protection (shields) or full tank-head jackets must meet...

  17. Recent Advances in Thermoplastic Puncture-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Bogert, Philip B.; Working, Dennis C.; Wise, Kristopher E.; Smith, Janice Y.; Topping, Crystal C.; Britton, Sean M.; Bagby, Paul R.; Siochi, Emilie J.

    2010-01-01

    The motivation for this work is to develop self-healing polymeric materials to enable damage tolerant systems, and to tailor puncture healing for use temperatures and applications. This will be a benefit in environments and conditions where access for manual repair is limited or impossible, or where damage may not be detected.

  18. Combined coding and delay-throughput analysis for fading channels of mobile satellite communications

    NASA Technical Reports Server (NTRS)

    Wang, C. C.; Yan, Tsun-Yee

    1986-01-01

    This paper presents the analysis of using the punctured convolutional code with Viterbi decoding to improve communications reliability. The punctured code rate is optimized so that the average delay is minimized. The coding gain in terms of the message delay is also defined. Since using punctured convolutional code with interleaving is still inadequate to combat the severe fading for short packets, the use of multiple copies of assignment and acknowledgment packets is suggested. The performance on the average end-to-end delay of this protocol is analyzed. It is shown that a replication of three copies for both assignment packets and acknowledgment packets is optimum for the cases considered.

  19. Rapidly developing gas gangrene due to a simple puncture wound.

    PubMed

    Oncel, Selim; Arsoy, Emin Sami

    2010-06-01

    Gas gangrene, an infection caused by Clostridium perfringens, is a potentially fatal and physically disabling disease due to its sometimes incredibly rapid progression. An adolescent boy was referred to our university hospital with a history of nail puncture in the hand that occurred a few hours previously. The physical examination revealed a swollen and tender arm with crepitations up to the shoulder. Gas was coming out from the puncture wound with digital pressure on the forearm. The plain radiograph of the arm was typical of gas gangrene with the presence of gas under the skin and between muscular fibrils.Having received 1 dose of meropenem, the boy had surgery, in which his entire upper extremity had to be disarticulated from the shoulder. The maintenance antimicrobial therapy with intravenously administered penicillin G and clindamycin was continued for a duration of 10 days, at the end of which, the patient was discharged.The rapidly progressive character and the dramatic ending of this case made us wonder whether antimicrobial prophylaxis would play any role in the preventive management of puncture wounds.

  20. A new posterior iliac puncture/aspiration needle.

    PubMed

    Islam, Anwarul

    2016-03-25

    The needles that are currently used for obtaining bone marrow aspirate samples from the posterior ilium are typically those of 1930s vintage (eg, Klima, Salah or similar needles), which were specifically designed for sternal aspiration. These needles are not designed to obtain bone marrow aspirate samples from the posterior ilium and as a result they are unsatisfactory particularly if the patient is large or obese. A new posterior iliac puncture/aspiration needle has therefore been designed, which is particularly suited for bone marrow aspiration from the posterior ilium. The needle was tested on five cadavers and on five patients. The design and construction of the needle was found to be satisfactory and a marked improvement over the conventional sternal puncture needles particularly when large or obese patients were concerned. The new posterior iliac bone marrow aspiration needle has advantages that overcome the limitations of using a conventional sternal puncture needle to obtain marrow aspirates from the posterior ilium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Simple Systems for Detecting Spacecraft Meteoroid Punctures

    NASA Technical Reports Server (NTRS)

    Hall, Stephen B.

    2004-01-01

    A report describes proposed systems to be installed in spacecraft to detect punctures by impinging meteoroids or debris. Relative to other systems that have been used for this purpose, the proposed systems would be simpler and more adaptable, and would demand less of astronauts attention and of spacecraft power and computing resources. The proposed systems would include a thin, hollow, hermetically sealed panel containing an inert fluid at a pressure above the spacecraft cabin pressure. A transducer would monitor the pressure in the panel. It is assumed that an impinging object that punctures the cabin at the location of the panel would also puncture the panel. Because the volume of the panel would be much smaller than that of the cabin, the panel would lose its elevated pressure much faster than the cabin would lose its lower pressure. The transducer would convert the rapid pressure drop to an electrical signal that could trigger an alarm. Hence, the system would provide an immediate indication of the approximate location of a small impact leak, possibly in time to take corrective action before a large loss of cabin pressure could occur.

  2. Mathematical Analysis of Space Radiator Segmenting for Increased Reliability and Reduced Mass

    NASA Technical Reports Server (NTRS)

    Juhasz, Albert J.

    2001-01-01

    Spacecraft for long duration deep space missions will need to be designed to survive micrometeoroid bombardment of their surfaces some of which may actually be punctured. To avoid loss of the entire mission the damage due to such punctures must be limited to small, localized areas. This is especially true for power system radiators, which necessarily feature large surface areas to reject heat at relatively low temperature to the space environment by thermal radiation. It may be intuitively obvious that if a space radiator is composed of a large number of independently operating segments, such as heat pipes, a random micrometeoroid puncture will result only in the loss of the punctured segment, and not the entire radiator. Due to the redundancy achieved by independently operating segments, the wall thickness and consequently the weight of such segments can be drastically reduced. Probability theory is used to estimate the magnitude of such weight reductions as the number of segments is increased. An analysis of relevant parameter values required for minimum mass segmented radiators is also included.

  3. A model of motor performance during surface penetration: from physics to voluntary control.

    PubMed

    Klatzky, Roberta L; Gershon, Pnina; Shivaprabhu, Vikas; Lee, Randy; Wu, Bing; Stetten, George; Swendsen, Robert H

    2013-10-01

    The act of puncturing a surface with a hand-held tool is a ubiquitous but complex motor behavior that requires precise force control to avoid potentially severe consequences. We present a detailed model of puncture over a time course of approximately 1,000 ms, which is fit to kinematic data from individual punctures, obtained via a simulation with high-fidelity force feedback. The model describes puncture as proceeding from purely physically determined interactions between the surface and tool, through decline of force due to biomechanical viscosity, to cortically mediated voluntary control. When fit to the data, it yields parameters for the inertial mass of the tool/person coupling, time characteristic of force decline, onset of active braking, stopping time and distance, and late oscillatory behavior, all of which the analysis relates to physical variables manipulated in the simulation. While the present data characterize distinct phases of motor performance in a group of healthy young adults, the approach could potentially be extended to quantify the performance of individuals from other populations, e.g., with sensory-motor impairments. Applications to surgical force control devices are also considered.

  4. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  5. Impact of Smartphone Applications on Timing of Endovascular Therapy for Ischemic Stroke: A Preliminary Study.

    PubMed

    Alotaibi, Naif M; Sarzetto, Francesca; Guha, Daipayan; Lu, Michael; Bodo, Andre; Gupta, Shaurya; Dyer, Erin; Howard, Peter; da Costa, Leodante; Swartz, Richard H; Boyle, Karl; Nathens, Avery B; Yang, Victor X D

    2017-11-01

    The metrics of imaging-to-puncture and imaging-to-reperfusion were recently found to be associated with the clinical outcomes of endovascular thrombectomy for acute ischemic stroke. However, measures for improving workflow within hospitals to achieve better timing results are largely unexplored for endovascular therapy. The aim of this study was to examine our experience with a novel smartphone application developed in house to improve our timing metrics for endovascular treatment. We developed an encrypted smartphone application connecting all stroke team members to expedite conversations and to provide synchronized real-time updates on the time window from stroke onset to imaging and to puncture. The effects of the application on the timing of endovascular therapy were evaluated with a secondary analysis of our single-center cohort. Our primary outcome was imaging-to-puncture time. We assessed the outcomes with nonparametric tests of statistical significance. Forty-five patients met our criteria for analysis among 66 consecutive patients with acute ischemic stroke who received endovascular therapy at our institution. After the implementation of the smartphone application, imaging-to-puncture time was significantly reduced (preapplication median time, 127 minutes; postapplication time, 69 minutes; P < 0.001). Puncture-to-reperfusion time was not affected by the application use (42 minutes vs. 36 minutes). The use of smartphone applications may reduce treatment times for endovascular therapy in acute ischemic stroke. Further studies are needed to confirm our findings. Copyright © 2017. Published by Elsevier Inc.

  6. Plantar and Pedal Puncture Wounds in Children: A Case Series Study From a Single Level I Trauma Center.

    PubMed

    Volk, Angela; Zebda, Mohamed; Abdelgawad, Amr A

    2017-11-01

    The purpose of this study was to describe our experience in treatment of pediatric patient presenting with pedal puncture wound to our level I trauma center and describe our results for the need for hospitalization and/or surgery for these patients. Children and adolescents 18 years and younger presenting with pedal puncture wounds from September 2009 to December of 2013 were retrospectively studied. Exclusion criteria included adult patients, wounds related to animal bites, lacerations associated with a motor vehicle collision or all-terrain vehicle accidents, gunshot wounds, degloving injuries, or injuries resulting in complex lacerations to the foot. A total of 147 children presented to emergency department (ED) with a pedal puncture wound. Average age was 9.8 years. Prophylactic antibiotic therapy was administered in 107 cases (72.8%). Fifteen patients (10%) were treated with intravenous or intramuscular antibiotics in the ED or after hospital admission, 81 patients (55%) were treated with oral medications (prescribed for them to be taken after discharge), and 35 patients (24%) received topical antibiotic treatment. Of the 147 patients included in the study, 9 patients (6%) required the need for hospitalization. Two patients were admitted for parenteral antibiotic treatment only, and 7 patients required formal surgical debridement in the operating room in addition to parenteral antibiotic therapy. The majority of pediatric patients with pedal puncture wounds were treated in the ED with only a small percentage of patients requiring admission for either parenteral antibiotic treatment or formal surgical debridement.

  7. Factors Associated With the Onset and Persistence of Post–Lumbar Puncture Headache

    PubMed Central

    Monserrate, Andrés E.; Ryman, Davis C.; Ma, Shengmei; Xiong, Chengjie; Noble, James M.; Ringman, John M.; Morris, John C.; Danek, Adrian; Müller-Sarnowski, Felix; Clifford, David B.; McDade, Eric M.; Brooks, William S.; Darby, David G.; Masters, Colin L.; Weston, Philip S. J.; Farlow, Martin R.; Graff-Radford, Neill R.; Salloway, Stephen P.; Fagan, Anne M.; Oliver, Angela; Bateman, Randall J.

    2015-01-01

    IMPORTANCE This study assesses factors associated with the most common adverse event following lumbar puncture. OBJECTIVE To identify factors associated with the risk, onset, and persistence of post–dural puncture headache (PDPH). DESIGN, SETTING, AND PARTICIPANTS We performed univariate and multivariable analyses of 338 lumbar punctures in the Dominantly Inherited Alzheimer Network observational study using linear mixed models, adjusting for participant-level and family-level random effects. MAIN OUTCOMES AND MEASURES We directly evaluated associations of 3 post–lumbar puncture outcomes (immediate postprocedural headache, PDPH at 24-hour follow-up, and PDPH receiving a therapeutic blood patch) with participant age and sex, positioning, collection method, needle size, needle insertion site, and cerebrospinal fluid (CSF) volume collected. RESULTS The incidence of adverse events included 73 immediate postprocedural headaches (21.6%), 59 PDPHs at 24-hour follow-up (17.5%), and 15 PDPHs receiving a therapeutic blood patch (4.4%). Greater volume of CSF collected was associated with increased risk of immediate postprocedural headache, largely owing to a nonlinear increase in risk on collection of volumes above 30 mL (odds ratio, 3.73 for >30 mL and 0.98 for <17 mL). In contrast, collection of higher volumes showed a protective effect in decreasing rates of PDPH at 24-hour follow-up and rates of PDPH receiving a therapeutic blood patch (odds ratio, 0.35 per 10 mL). Although differences in needle size did not reach statistical significance, no participant in the 24G needle group received a therapeutic blood patch compared to 8 of 253 for the larger 22G needles. CONCLUSIONS AND RELEVANCE Factors that acutely lower CSF pressure (eg, seated positioning or extracting very high volumes of CSF) may be associated with transient post-lumbar puncture headache, without increasing rates of persistent PDPH or therapeutic blood patch. Collection of up to 30 mL of CSF appears to be well tolerated and safe. PMID:25622095

  8. Microneedle Arrays Allow Lower Microbial Penetration Than Hypodermic Needles In Vitro

    PubMed Central

    Donnelly, Ryan F.; Singh, Thakur Raghu Raj; Tunney, Michael M.; Morrow, Desmond I. J.; McCarron, Paul A.; O’Mahony, Conor; Woolfson, A. David

    2010-01-01

    Methods In this study we determined, for the first time, the ability of microorganisms to traverse microneedle-induced holes using two different in vitro models. Results When employing Silescol® membranes, the numbers of Candida albicans, Pseudomonas aeruginosa and Staphylococcus epidermidis crossing the membranes were an order of magnitude lower when the membranes were punctured by microneedles rather than a 21G hypodermic needle. Apart from the movement of C. albicans across hypodermic needle-punctured membranes, where 40.2% of the microbial load on control membranes permeated the barrier over 24 h, the numbers of permeating microorganisms was less than 5% of the original microbial load on control membranes. Experiments employing excised porcine skin and radiolabelled microorganisms showed that the numbers of microorganisms penetrating skin beyond the stratum corneum were approximately an order of magnitude greater than the numbers crossing Silescol® membranes in the corresponding experiments. Approximately 103cfu of each microorganism adhered to hypodermic needles during insertion. The numbers of microorganisms adhering to MN arrays were an order of magnitude higher in each case. Conclusion We have shown here that microneedle puncture resulted in significantly less microbial penetration than did hypodermic needle puncture and that no microorganisms crossed the viable epidermis in microneedle—punctured skin, in contrast to needle-punctured skin. Given the antimicrobial properties of skin, it is, therefore, likely that application of microneedle arrays to skin in an appropriate manner would not cause either local or systemic infection in normal circumstances in immune-competent patients. In supporting widespread clinical use of microneedle-based delivery systems, appropriate animal studies are now needed to conclusively demonstrate this in vivo. Safety in patients will be enhanced by aseptic or sterile manufacture and by fabricating microneedles from self-disabling materials (e.g. dissolving or biodegradable polymers) to prevent inappropriate or accidental reuse. PMID:19756972

  9. Self-taught axillary vein access without venography for pacemaker implantation: prospective randomized comparison with the cephalic vein access.

    PubMed

    Squara, Fabien; Tomi, Julien; Scarlatti, Didier; Theodore, Guillaume; Moceri, Pamela; Ferrari, Emile

    2017-12-01

    Axillary vein access for pacemaker implantation is uncommon in many centres because of the lack of training in this technique. We assessed whether the introduction of the axillary vein technique was safe and efficient as compared with cephalic vein access, in a centre where no operators had any previous experience in axillary vein puncture. Patients undergoing pacemaker implantation were randomized to axillary or cephalic vein access. All three operators had no experience nor training in axillary vein puncture, and self-learned the technique by reading a published review. Axillary vein puncture was fluoroscopy-guided without contrast venography. Cephalic access was performed by dissection of delto-pectoral groove. Venous access success, venous access duration (from skin incision to guidewire or lead in superior vena cava), procedure duration, X-ray exposure, and peri-procedural (1 month) complications were recorded. results We randomized 74 consecutive patients to axillary (n = 37) or cephalic vein access (n = 37). Axillary vein was successfully accessed in 30/37 (81.1%) patients vs. 28/37 (75.7%) of cephalic veins (P = 0.57). Venous access time was shorter in axillary group than in cephalic group [5.7 (4.4-8.3) vs. 12.2 (10.5-14.8) min, P < 0.001], as well as procedure duration [34.8 (30.6-38.4) vs. 42.0 (39.1-46.6) min, P = 0.043]. X-ray exposure and peri-procedural overall complications were comparable in both groups. Axillary puncture was safe and faster than cephalic access even for the five first procedures performed by each operator. Self-taught axillary vein puncture for pacemaker implantation seems immediately safe and faster than cephalic vein access, when performed by electrophysiologists trained to pacemaker implantation but not to axillary vein puncture. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For Permissions, please email: journals.permissions@oup.com.

  10. [Comparison of efficacy and complications of 27G and 29G Sprottte needles for subarachnoid anesthesia].

    PubMed

    Morros-Viñoles, C; Pérez-Cuenca, M D; Cedó-Lluís, E; Colls, C; Bueno, J; Cedó-Vallobá, F

    2002-11-01

    Post-dural puncture headache and lumbar backache are related to needle gauge and type of point used. We aimed to determine whether the incidence of post-dural puncture headache and lumbar backache could be reduced by using fine gauge pencil-point Sprotte 27G and 29G needles. We also studied increases in technical difficulty with these needles and whether or not reducing needle gauge affected anesthetic quality. Three hundred eighty-nine patients undergoing orthopedic or lower abdominal surgery were randomly assigned to two groups for dural puncture using two Sprotte needles: 27G or 29G. We recorded time to perform puncture, number of re-insertations of the needle, number of times the technique was abandoned and anesthetic efficacy. On the second and seventh days, the patients were interviewed by telephone to check for the presence and severity of post-dural puncture headache or lumbar backache. The technical difficulty was greater with the Sprotte 29G needle, as shown by significant differences in time taken to perform the puncture and the number of re-insertions (p < 0.05). Anesthetic quality was the same in both groups and the percentage of failures was 0.5% for both. Five percent of patients in the 27G group and 3% in the 29G group experienced slight or moderate headache on the second day. No cases of severe cephalea were reported. Lumbar backache was reported on the second day by 26% and 18.5% of the patients in the 27G and 29G groups, respectively, but the rates decreased to 4.5% and 0.5% on the seventh day. The differences were significant, favoring the 29G needle. The use of 29G pencil-point needles can be recommended to reduce the incidence of headache and lumbar backache in the postoperative period, in spite of the greater technical difficulty involved, given that quality of anesthesia is maintained.

  11. Three-Dimensional Ultrasound-Guided Real-Time Midline Epidural Needle Placement with Epiguide: A Prospective Feasibility Study.

    PubMed

    Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit

    2017-01-01

    Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Operationalising elaboration theory for simulation instruction design: a Delphi study.

    PubMed

    Haji, Faizal A; Khan, Rabia; Regehr, Glenn; Ng, Gary; de Ribaupierre, Sandrine; Dubrowski, Adam

    2015-06-01

    The aim of this study was to assess the feasibility of incorporating the Delphi process within the simplifying conditions method (SCM) described in elaboration theory (ET) to identify conditions impacting the complexity of procedural skills for novice learners. We generated an initial list of conditions impacting the complexity of lumbar puncture (LP) from key informant interviews (n = 5) and a literature review. Eighteen clinician-educators from six different medical specialties were subsequently recruited as expert panellists. Over three Delphi rounds, these panellists rated: (i) their agreement with the inclusion of the simple version of the conditions in a representative ('epitome') training scenario, and (ii) how much the inverse (complex) version increases LP complexity for a novice. Cronbach's α-values were used to assess inter-rater agreement. All panellists completed Rounds 1 and 2 of the survey and 17 completed Round 3. In Round 1, Cronbach's α-values were 0.89 and 0.94 for conditions that simplify and increase LP complexity, respectively; both values increased to 0.98 in Rounds 2 and 3. With the exception of 'high CSF (cerebral spinal fluid) pressure', panellists agreed with the inclusion of all conditions in the simplest (epitome) training scenario. Panellists rated patient movement, spinal anatomy, patient cooperativeness, body habitus, and the presence or absence of an experienced assistant as having the greatest impact on the complexity of LP. This study demonstrated the feasibility of using expert consensus to establish conditions impacting the complexity of procedural skills, and the benefits of incorporating the Delphi method into the SCM. These data can be used to develop and sequence simulation scenarios in a progressively challenging manner. If the theorised learning gains associated with ET are realised, the methods described in this study may be applied to the design of simulation training for other procedural and non-procedural skills, thereby advancing the agenda of theoretically based instruction design in health care simulation. © 2015 John Wiley & Sons Ltd.

  13. Injection of AAV2-BMP2 and AAV2-TIMP1 into the nucleus pulposus slows the course of intervertebral disc degeneration in an in vivo rabbit model.

    PubMed

    Leckie, Steven K; Bechara, Bernard P; Hartman, Robert A; Sowa, Gwendolyn A; Woods, Barrett I; Coelho, Joao P; Witt, William T; Dong, Qing D; Bowman, Brent W; Bell, Kevin M; Vo, Nam V; Wang, Bing; Kang, James D

    2012-01-01

    Intervertebral disc degeneration (IDD) is a common cause of back pain. Patients who fail conservative management may face the morbidity of surgery. Alternative treatment modalities could have a significant impact on disease progression and patients' quality of life. To determine if the injection of a virus vector carrying a therapeutic gene directly into the nucleus pulposus improves the course of IDD. Prospective randomized controlled animal study. Thirty-four skeletally mature New Zealand white rabbits were used. In the treatment group, L2-L3, L3-L4, and L4-L5 discs were punctured in accordance with a previously validated rabbit annulotomy model for IDD and then subsequently treated with adeno-associated virus serotype 2 (AAV2) vector carrying genes for either bone morphogenetic protein 2 (BMP2) or tissue inhibitor of metalloproteinase 1 (TIMP1). A nonoperative control group, nonpunctured sham surgical group, and punctured control group were also evaluated. Serial magnetic resonance imaging (MRI) studies at 0, 6, and 12 weeks were obtained, and a validated MRI analysis program was used to quantify degeneration. The rabbits were sacrificed at 12 weeks, and L4-L5 discs were analyzed histologically. Viscoelastic properties of the L3-L4 discs were analyzed using uniaxial load-normalized displacement testing. Creep curves were mathematically modeled according to a previously validated two-phase exponential model. Serum samples obtained at 0, 6, and 12 weeks were assayed for biochemical evidence of degeneration. The punctured group demonstrated MRI and histologic evidence of degeneration as expected. The treatment groups demonstrated less MRI and histologic evidence of degeneration than the punctured group. The serum biochemical marker C-telopeptide of collagen type II increased rapidly in the punctured group, but the treated groups returned to control values by 12 weeks. The treatment groups demonstrated several viscoelastic properties that were distinct from control and punctured values. Treatment of punctured rabbit intervertebral discs with AAV2-BMP2 or AAV2-TIMP1 helps delay degenerative changes, as seen on MRI, histologic sampling, serum biochemical analysis, and biomechanical testing. Although data from animal models should be extrapolated to the human condition with caution, this study supports the potential use of gene therapy for the treatment of IDD. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Atraumatic versus traumatic lumbar puncture needles: a systematic review and meta-analysis protocol

    PubMed Central

    Nath, Siddharth; Badhiwala, Jetan H; Alhazzani, Waleed; Nassiri, Farshad; Belley-Cote, Emilie; Koziarz, Alex; Shoamanesh, Ashkan; Banfield, Laura; Oczkowski, Wieslaw; Sharma, Mike; Sahlas, Demetrios; Reddy, Kesava; Farrokhyar, Forough; Singh, Sheila; Sharma, Sunjay; Zytaruk, Nicole; Selim, Magdy; Almenawer, Saleh A

    2017-01-01

    Introduction Lumbar puncture is one of the oldest and most commonly performed procedures in medicine, used to diagnose and treat disease. Headache following lumbar puncture remains a frequent complication, causing significant patient discomfort and often requiring narcotic analgesia or invasive therapy. Needle tip design has been proposed to affect the incidence of headache postlumbar puncture, with pencil-point ‘atraumatic’ needles thought to reduce its incidence in comparison to bevelled ‘traumatic’ needles. Despite this, the use of atraumatic needles and knowledge of their existence remains significantly limited among clinicians. This study will systematically review the evidence on atraumatic lumbar puncture needles and compare them with traumatic needles across a variety of clinical outcomes. Methods and analyses We will include published randomised controlled trials (RCTs), observational studies and abstracts, with no publication type or language restrictions. Search strategies will be designed to peruse the MEDLINE, EMBASE, Web of Science, ClinicalTrials.gov, CINAHL, WHO Clinical Trials Database and Cochrane Library databases. We will also implement strategies to search the grey literature. 3 reviewers will thoroughly and independently examine the search results, complete data abstraction and conduct quality assessment. Included RCTs will be assessed using the Cochrane risk of bias assessment tool and eligible observational studies will be examined using the Newcastle-Ottawa Scale. We will examine the outcomes of: headache and its type, intensity, duration and treatment; backache; success rate; hearing disturbance and nerve root irritation. The primary outcome will be the incidence of postdural puncture headache. We will calculate pooled estimates, relative risks for dichotomous outcomes and weighted mean differences for continuous outcomes, with corresponding 95% CIs. Statistical heterogeneity will be measured using Cochran's Q test and quantified using the I2 statistic. We will also conduct prespecified subgroup and sensitivity analyses to examine if covariates exist and to explore potential heterogeneity. Ethics and dissemination Research ethics board approval is not required for this study as it draws from published data and raises no concerns related to patient privacy. This review will provide a comprehensive assessment of the evidence on atraumatic needles for lumbar puncture and is directed to a wide audience. Results from the review will be disseminated extensively through conferences and submitted to a peer-reviewed journal for publication. Trial registration number CRD42016047546. PMID:28363928

  15. Is fracture a bigger problem for smaller animals? Force and fracture scaling for a simple model of cutting, puncture and crushing

    PubMed Central

    Choi, Seunghee; Coon, Joshua J.; Goggans, Matthew Scott; Kreisman, Thomas F.; Silver, Daniel M.; Nesson, Michael H.

    2016-01-01

    Many of the materials that are challenging for large animals to cut or puncture are also cut and punctured by much smaller organisms that are limited to much smaller forces. Small organisms can overcome their force limitations by using sharper tools, but one drawback may be an increased susceptibility to fracture. We use simple contact mechanics models to estimate how much smaller the diameter of the tips or edges of tools such as teeth, claws and cutting blades must be in smaller organisms in order for them to puncture or cut the same materials as larger organisms. In order to produce the same maximum stress when maximum force scales as the square of body length, the diameter of the tool region that is in contact with the target material must scale isometrically for punch-like tools (e.g. scorpion stings) on thick targets, and for crushing tools (e.g. molars). For punch-like tools on thin targets, and for cutting blades on thick targets, the tip or edge diameters must be even smaller than expected from isometry in smaller animals. The diameters of a small sample of unworn punch-like tools from a large range of animal sizes are consistent with the model, scaling isometrically or more steeply (positively allometric). In addition, we find that the force required to puncture a thin target using real biological tools scales linearly with tip diameter, as predicted by the model. We argue that, for smaller tools, the minimum energy to fracture the tool will be a greater fraction of the minimum energy required to puncture the target, making fracture more likely. Finally, energy stored in tool bending, relative to the energy to fracture the tool, increases rapidly with the aspect ratio (length/width), and we expect that smaller organisms often have to employ higher aspect ratio tools in order to puncture or cut to the required depth with available force. The extra stored energy in higher aspect ratio tools is likely to increase the probability of fracture. We discuss some of the implications of the suggested scaling rules and possible adaptations to compensate for fracture sensitivity in smaller organisms. PMID:27274804

  16. Wireless Visual Sensor Network Resource Allocation using Cross-Layer Optimization

    DTIC Science & Technology

    2009-01-01

    Rate Compatible Punctured Convolutional (RCPC) codes for channel...vol. 44, pp. 2943–2959, November 1998. [22] J. Hagenauer, “ Rate - compatible punctured convolutional codes (RCPC codes ) and their applications,” IEEE... coding rate for H.264/AVC video compression is determined. At the data link layer, the Rate - Compatible Puctured Convolutional (RCPC) channel coding

  17. Chylous Ascites: A Rare Complication of Thoracic Duct Embolization for Chylothorax

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaba, Ron C., E-mail: rgaba@uic.edu; Owens, Charles A.; Bui, James T.

    2011-02-15

    Thoracic duct embolization represents a safe and effective method to treat postsurgical chylothorax. Complications of this procedure are rare despite transabdominal puncture of lymphatic channels for thoracic duct access, and chylous ascites is unreported. Herein, we describe a case of chylous ascites formation after lymphatic puncture and attempted cannulation. Our management approach is also discussed.

  18. 75 FR 71528 - Airworthiness Directives; Dassault-Aviation Model FALCON 7X Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-24

    ... aeroplanes might, in the event of belly or gear-up landing, puncture the rear fuel tank, which could result in fuel leakage and post- landing fire. We are issuing this AD to require actions to correct the... belly or gear-up landing, puncture the rear fuel tank, which could result in fuel leakage and post...

  19. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance.

    PubMed

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index - 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic-therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations.

  20. Transfundal puncture of a large ovarian cyst with hysteroscopic and ultrasonographic guidance

    PubMed Central

    Zolnierczyk, Piotr; Cendrowski, Krzysztof; Sawicki, Wlodzimierz

    2015-01-01

    This paper describes the case of an 83-year-old patient with hypertension, diabetes, obesity (body mass index – 38), congestive heart failure, and history of cardiac surgery, who was referred for a diagnostic–therapeutic decompression of a large, symptomatic ovarian cyst. Due to anatomical conditions, the only safe way was a transfundal puncture under mini-hysteroscopic and ultrasound guidance. A puncture with aspiration of 300 mL of serous fluid from the cyst was performed without technical problems and complications. Cytology showed no cancer cells in the examined liquid. Relief from pain and compression discomfort was achieved in the patient. This case shows the possibility of combining ultrasound and minimally invasive diagnostic methods like hysteroscopy in selected clinical situations. PMID:25999768

  1. Ultrasound guided V3 segment vertebral artery direct percutaneous puncture for basilar artery mechanical thrombectomy in acute stroke: a technical report.

    PubMed

    Desai, Jamsheed A; Almekhlafi, Mohammed A; Hill, Michael D; Goyal, Mayank; Eesa, Muneer

    2014-04-01

    A middle aged patient presented with acute ischemic stroke due to basilar artery occlusion. The patient clinically deteriorated despite intravenous thrombolysis and was referred for mechanical thrombectomy. The right vertebral artery was occluded and could not be accessed despite attempting various shaped catheters, even when a radial artery access was used. The left vertebral artery ended in the posterior inferior cerebellar artery. Eventually, ultrasound guided V3 segment vertebral artery direct puncture was successfully done and the procedure was completed. No access related complications were encountered. Direct cervical arterial puncture can be safely used by experienced operators as a last resort in acute stroke cases with difficult access.

  2. Computed tomography imaging and angiography - principles.

    PubMed

    Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv

    2016-01-01

    The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. © 2016 Elsevier B.V. All rights reserved.

  3. Ehrlichia Meningitis Mimicking Aneurysmal Subarachnoid Hemorrhage: A Case Study for Medical Decision-Making Heuristics.

    PubMed

    Dredla, Brynn; Freeman, William D

    2016-04-01

    Thunderclap headache is a sudden and severe headache that can occur after an aneurysmal subarachnoid hemorrhage (SAH). Subarachnoid hemorrhage is a medical emergency that requires prompt attention and hospitalization. Patients with thunderclap headache often undergo a noncontrast head computed tomography (CT) scan to ascertain SAH bleeding and, if the scan is negative, then undergo a lumbar puncture to look for cerebrospinal fluid (CSF) red blood cells (RBCs), which would be consistent with an aneurysmal leak. If the initial CT is negative and CSF is positive for RBCs, patients are usually admitted to the hospital for evaluation of intracranial aneurysm. We encountered a patient with thunderclap headache whose initial head CT was negative for SAH and whose CSF tested positive for RBCs. The patient was referred to our center for evaluation and management of aneurysmal SAH. However, on careful review of the patient's medical history, serum laboratory values, and spinal fluid values, the patient was diagnosed with Ehrlichia chaffeensis meningitis. While Ehrlichia meningitis is rare, it is important to recognize the clinical clues that could help avoid formal cerebral angiography, a costly and potentially unnecessary procedure. We present how this case represented a cognitive framing bias and anchoring heuristic as well as steps that medical providers can use to prevent such cognitive errors in diagnosis.

  4. Pleural Puncture that Excludes the Ablation Zone Decreases the Risk of Pneumothorax after Percutaneous Microwave Ablation in Porcine Lung

    PubMed Central

    Lee, Kyungmouk Steve; Takaki, Haruyuki; Yarmohammadi, Hooman; Srimathveeravalli, Govindarajan; Luchins, Kerith; Monette, Sébastien; Nair, Sreejit; Kishore, Sirish; Erinjeri, Joseph P.

    2017-01-01

    Purpose To test the hypothesis that the geometry of probe placement with respect to the pleural puncture site affects the risk of pneumothorax after microwave (MW) ablation in the lung. Materials and Methods Computed tomography–guided MW ablation of the lung was performed in 8 swine under general anesthesia and mechanical ventilation. The orientation of the 17-gauge probe was either perpendicular (90°) or parallel (< 30°) with respect to the pleural puncture site, and the ablation power was 30 W or 65 W for 5 minutes. After MW ablation, swine were euthanized, and histopathologic changes were assessed. Frequency and factors affecting pneumothorax were evaluated by multivariate analysis. Results Among 62 lung MW ablations, 13 (21%) pneumothoraces occurred. No statistically significant difference was noted in the rate of pneumothorax between the perpendicular and the parallel orientations of the probe (31% vs 14%; odds ratio [OR], 2.8; P = .11). The pneumothorax rate was equal for 65-W and 30-W ablation powers (21% and 21%; OR, 1.0; P = .94). Under multivariate analysis, 2 factors were independent positive predictors of pneumothorax: ablation zone inclusive of pleural insertion point (OR, 7.7; P = .02) and time since intubation (hours) (OR, 2.7; P = .02). Conclusions Geometries where the pleural puncture site excluded the ablation zone decreased pneumothorax in swine undergoing MW ablation in the lung. Treatment planning to ensure that the pleural puncture site excludes the subsequent ablation zone may reduce the rate of pneumothorax in patients undergoing MW ablation in the lung. PMID:25753501

  5. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  6. Cancer Seeding Risk from an Epidural Blood Patch in Patients with Leukemia or Lymphoma.

    PubMed

    Demaree, Christopher J; Soliz, Jose M; Gebhardt, Rodolfo

    2017-04-01

    Lumber punctures are a common procedure in patients with cancer. However, a potential complication of a lumbar puncture is a postdural puncture headache. The risk of neoplastic seeding to the central nervous system has led to concern over performing epidural blood patches (EBPs) for the treatment of postdural puncture headaches in patients with cancer. The goal of this retrospective study was to evaluate cancer seeding in the central nervous system in patients diagnosed with leukemia or lymphoma. Institutional electronic records were queried over a 13-year period from 2000 to 2013 for patients with leukemia and/or lymphoma and who received at least one EBP. Demographic and procedural data, cancer treatments, and mortality were all examined. Patient records were reviewed for evidence of new-onset neoplastic central nervous system seeding after an epidural blood patch. A total of 80 patients were identified for review. Eighteen patients had a diagnosis of leukemia, and 62 had lymphoma. Following an EBP, none of the patients experienced new cancer or cancer seeding in the central nervous system following an epidural blood patch at a median follow-up of 3.74 years. Though the risks of EBP in the cancer patient population have been hypothesized, no previous studies have assessed the risk of seeding cancer to the central nervous system. Based on our results, an epidural blood patch bears low risk of cancer seeding when used to treat postdural puncture headache that is unresponsive to conservative treatments. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. REcanalisation and Balloon-Oriented Puncture for Re-Insertion of Dialysis Catheter in Nonpatent Central Veins (REBORN)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Too, Chow Wei, E-mail: toochowwei@gmail.com; Sayani, Raza; Lim, Elvin Yuan Ting

    PurposeTo describe a technique involving REcanalisation and Balloon-Oriented puncture for Re-insertion of dialysis catheter in Nonpatent central veins (REBORN) and to report long-term results.Materials and MethodsThis is a retrospective study of ten subjects in whom dialysis catheters were inserted using the REBORN technique from March 2012 to October 2014 and followed up till April 2016. Data on the duration of catheter usage, complications and reasons for removal were obtained. Seven patients had partially occluded lower internal jugular veins (IJV) recanalised in an antegrade fashion via a more cranial puncture. The balloon was then inflated at usual puncture site with anmore » 18G needle. The collapsed balloon was cannulated with a guide wire, and both balloon and guide wire were advanced together into the superior vena cava. This was followed by tunnelled catheter placement using standard techniques. Two patients had catheters placed in the subclavian vein using a similar antegrade technique, and one patient had catheter placed via the left IJV following retrograde recanalisation from a right femoral puncture.ResultsMean duration of catheter use was 278 days (range 32–503). Three catheters were removed due to matured arteriovenous accesses. Four patients had successful catheter change over the same subcutaneous track due to catheter malfunction. One catheter was removed after 7 months because of sepsis. No complications were reported.ConclusionThe REBORN technique allows for the preservation of central veins for future haemodialysis access, which can be challenging in patients requiring long-term dialysis.« less

  8. Feasibility of the Use of Transesophageal Echocardiography as a Surface Probe for Puncturing and Catheterization of the Internal Jugular Vein: A Randomized Controlled Pilot Study.

    PubMed

    Teng, Yi; Ou, Mengchan; Yu, Hai

    2018-02-01

    To compare the transesophageal echocardiography (TEE) probe as a surface probe with the vascular probe for guiding internal jugular vein (IJV) catheterization. Prospective, randomized, controlled pilot study. University hospital. One hundred cardiac surgery patients, including 50 adult and 50 pediatric patients. Patients in the TEE probe group received right IJV catheterization using the TEE probe, while the vascular probe group used the vascular probe for catheterization. The puncture time, first-attempt success rate, quality of the imaging with needle tip positioning, wire positioning, and catheter positioning were recorded. The incidence of complication or any adverse event also was observed. Adult patients: In the vascular probe group, the success rate for first attempt IJV catheterization was 24/25 (96%), while in the TEE probe group, the success rate for first attempt IJV catheterization was 25/25 (100%). There was no statistical difference in the puncture time, image quality, needle tip positioning, wire positioning, and catheter positioning between groups (p > 0.05). Pediatric patients: The success rate for first-attempt IJV catheterization was 100% in both groups, and there were no statistical differences in the puncture time, image quality, and positioning between the 2 groups (p > 0.05). No complications or adverse events were observed in either group. The TEE probe, used as a surface probe, can be used to guide IJV puncturing and catheterization in cardiac surgery patients with favorable feasibility and safety. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Effect of protein and glycerol concentration on the mechanical, optical, and water vapor barrier properties of canola protein isolate-based edible films.

    PubMed

    Chang, Chang; Nickerson, Michael T

    2015-01-01

    Biodegradable edible films prepared using proteins are both economically and environmentally important to the food packaging industry relative to traditional petroleum-derived synthetic materials. In the present study, the mechanical and water vapor barrier properties of casted canola protein isolate edible films were investigated as a function of protein (5.0% and 7.5%) and glycerol (30%, 35%, 40%, 45%, and 50%) content. Specifically, tensile strength and elongation, elastic modulus, puncture strength and deformation, opacity, and water vapor permeability were measured. Results indicated that tensile strength, puncture strength, and elastic modulus decreased, while tensile elongation and puncture deformation values increased as glycerol concentration increased for both 5.0% and 7.5% canola protein isolate films. Furthermore, tensile strength, puncture strength, and elastic modulus values were found to increase at higher protein concentrations within the canola protein isolate films, whereas puncture deformation values decreased. Tensile elongation was found to be similar for both canola protein isolate protein levels. Canola protein isolate films became more transparent with increasing of glycerol concentration and decreasing of canola protein isolate concentration. Water vapor permeability value was also found to increase with increasing glycerol and protein contents. Overall, results indicated that canola protein isolate films were less brittle, more malleable and transparent, and had greater water vapor permeability at higher glycerol levels. However, as protein level increased, canola protein isolate films were more brittle, less malleable and more opaque, and also had increased water vapor permeability. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  10. Validation of percutaneous puncture trajectory during renal access using 4D ultrasound reconstruction

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; Vilaça, João. L.

    2015-03-01

    An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.

  11. Gauge Conditions for Moving Black Holes Without Excision

    NASA Technical Reports Server (NTRS)

    van Meter, James; Baker, John G.; Koppitz, Michael; Dae-IL, Choi

    2006-01-01

    Recent demonstrations of unexcised, puncture black holes traversing freely across computational grids represent a significant advance in numerical relativity. Stable an$ accurate simulations of multiple orbits, and their radiated waves, result. This capability is critically undergirded by a careful choice of gauge. Here we present analytic considerations which suggest certain gauge choices, and numerically demonstrate their efficacy in evolving a single moving puncture.

  12. System Design for FEC in Aeronautical Telemetry

    DTIC Science & Technology

    2012-03-12

    rate punctured convolutional codes for soft decision Viterbi...below follows that given in [8]. The final coding rate of exactly 2/3 is achieved by puncturing the rate -1/2 code as follows. We begin with the buffer c1...concatenated convolutional code (SCCC). The contributions of this paper are on the system-design level. One major contribution is to design a SCCC code

  13. Tinkertoys for the E 7 theory

    NASA Astrophysics Data System (ADS)

    Chacaltana, Oscar; Distler, Jacques; Trimm, Anderson; Zhu, Yinan

    2018-05-01

    We classify the class S theories of type E 7. These are four-dimensional N=2 superconformal field theories arising from the compactification of the E 7 (2, 0) theory on a punctured Riemann surface, C. The classification is given by listing all 3-punctured spheres ("fixtures"), and connecting cylinders, which can arise in a pants-decomposition of C. We find exactly 11,000 fixtures with three regular punctures, and an additional 48 with one "irregular puncture" (in the sense used in our previous works). To organize this large number of theories, we have created a web application at https://golem.ph.utexas.edu/class-S/E7/. Among these theories, we find 10 new ones with a simple exceptional global symmetry group, as well as a new rank-2 SCFT and several new rank-3 SCFTs. As an application, we study the strong-coupling limit of the E 7 gauge theory with 3 hypermultiplets in the 56. Using our results, we also verify recent conjectures that the T 2 compactification of certain 6 d (1, 0) theories can alternatively be realized in class S as fixtures in the E 7 or E 8 theories.

  14. Correlation of Descriptive Analysis and Instrumental Puncture Testing of Watermelon Cultivars.

    PubMed

    Shiu, J W; Slaughter, D C; Boyden, L E; Barrett, D M

    2016-06-01

    The textural properties of 5 seedless watermelon cultivars were assessed by descriptive analysis and the standard puncture test using a hollow probe with increased shearing properties. The use of descriptive analysis methodology was an effective means of quantifying watermelon sensory texture profiles for characterizing specific cultivars' characteristics. Of the 10 cultivars screened, 71% of the variation in the sensory attributes was measured using the 1st 2 principal components. Pairwise correlation of the hollow puncture probe and sensory parameters determined that initial slope, maximum force, and work after maximum force measurements all correlated well to the sensory attributes crisp and firm. These findings confirm that maximum force correlates well with not only firmness in watermelon, but crispness as well. The initial slope parameter also captures the sensory crispness of watermelon, but is not as practical to measure in the field as maximum force. The work after maximum force parameter is thought to reflect cellular arrangement and membrane integrity that in turn impact sensory firmness and crispness. Watermelon cultivar types were correctly predicted by puncture test measurements in heart tissue 87% of the time, although descriptive analysis was correct 54% of the time. © 2016 Institute of Food Technologists®

  15. CT fluoroscopy-assisted puncture of thoracic and abdominal masses: a randomized trial.

    PubMed

    Kirchner, Johannes; Kickuth, Ralph; Laufer, Ulf; Schilling, Esther Maria; Adams, Stephan; Liermann, Dieter

    2002-03-01

    We investigated the benefit of real-time guidance of interventional punctures by means of computed tomography fluoroscopy (CTF) compared with the conventional sequential acquisition guidance. In a prospective randomized trial, 75 patients underwent either CTF-guided (group A, n = 50) or sequential CT-guided (group B, n = 25) punctures of thoracic (n = 29) or abdominal (n = 46) masses. CTF was performed on the CT machine (Somatom Plus 4 Power, Siemens Corp., Forchheim, Germany) equipped with the C.A.R.E. Vision application (tube voltage 120 kV, tube current 50 mA, rotational time 0.75 s, slice thickness 10 mm, 8 frames/s). The average procedure time showed a statistically significant difference between the two study groups (group A: 564 s, group B 795 s, P = 0.0032). The mean total mAs was 7089 mAs for the CTF and 4856 mAs for the sequential image-guided intervention, respectively. The sensitivity was 71% specificity 100% positive predictive value 100% and negative predictive value 60% for the CTF-guided puncture, and 68, 100, 100 and 50% for sequential CT, respectively. CTF guidance realizes a time-saving but increases the radiation exposure dosage.

  16. Implantable venous ports in pediatric oncology: experience of single institution in Russia.

    PubMed

    Rykov, Maxim Yu; Polyakov, Vladimir G

    2016-07-12

    To review our experience with implantable venous port-systems (IVPs) in pediatric cancer patients. From 2010 to 2015 we were monitoring the treatment of 163 children (aged 3 months to 17 years) with oncologic diseases. These patients underwent venous port implantations. During insertion of 163 IVPs the following complications and technical difficulties were present: unintended puncture of the common carotid artery (CCA) during the puncture of the internal jugular vein (IJV) - 7 cases (4.3%); retrograde positioning of the distal end of the guidewire in the IJV - 17 cases (14.4%); placement of the distal end of the guidewire into the punctured subclavian vein (SV) - 12 cases (7.6%); difficulties driving the guidewire into the IJV after successful puncture - 15 cases (9.3%). The use of 163 IVPs was complicated by the following: venous port contamination - 4 cases (2.5%); occlusion of the IVPs by a clot - 8 cases (5%); withdrawal of the Huber needle bevel from the port chamber - 22 cases (13.6%); subcutaneous fat layer thinning above the port chamber - 3 cases (1.7%). There are many complications, but they can be reduced by proper choice of materials and methodology.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takizawa, Kenji, E-mail: khirari@marianna-u.ac.jp; Nakajima, Yasuo, E-mail: nakajima.yasuo@gmail.com; Ogawa, Yukihisa, E-mail: yukky.oct.22@gmail.com

    Purpose: The authors devised a new method of an axial puncture approach through the pulmonary apex (PA) for percutaneous catheter drainage (PCD) of loculated fluid collections extending to the PA. The purpose of this report is to introduce the new procedure. Methods: Percutaneous catheter drainage by the axial puncture approach was performed in two patients with limited supine position and loculated pleural fluid collection in the posteromedial part of thoracic cavity. Results: The procedures succeeded in two patients without difficulties while keeping them in a supine position, even if the loculated fluids exist in the posterior side of thoracic cavity.more » Conclusions: Percutaneous catheter drainage by the axial puncture approach is particularly effective in patients with limited supine positions and loculated pleural fluid collection in the posteromedial part of thoracic cavity.« less

  18. An in vitro comparison of fluid leakage after dural puncture with Atraucan, Sprotte, Whitacre, and Quincke needles.

    PubMed

    Morrison, L M; McCrae, A F; Foo, I; Scott, D B; Wildsmith, J A

    1996-01-01

    The study was designed to evaluate the influence of needle size and design on the rate of leakage following dural puncture. An in vitro model and fresh human lumbar dura were used to examine the rate of fluid leakage after puncture with Sprotte (24-gauge and 26-gauge), Atraucan (24-gauge and 26-gauge), Quincke (26-gauge and 29-gauge), and Whitacre (22-gauge and 25-gauge) needles. The study confirmed that finer-gauge needles tend to produce less leakage and that traditional Quincke pattern bevels result in greater leakage than pencil-point designs of the same diameter. The comparably low leakage rate produced by the Atraucan, a new needle with a terminal opening, suggests that this needle is worthy of further clinical evaluation.

  19. Nonclassical states of light with a smooth P function

    NASA Astrophysics Data System (ADS)

    Damanet, François; Kübler, Jonas; Martin, John; Braun, Daniel

    2018-02-01

    There is a common understanding in quantum optics that nonclassical states of light are states that do not have a positive semidefinite and sufficiently regular Glauber-Sudarshan P function. Almost all known nonclassical states have P functions that are highly irregular, which makes working with them difficult and direct experimental reconstruction impossible. Here we introduce classes of nonclassical states with regular, non-positive-definite P functions. They are constructed by "puncturing" regular smooth positive P functions with negative Dirac-δ peaks or other sufficiently narrow smooth negative functions. We determine the parameter ranges for which such punctures are possible without losing the positivity of the state, the regimes yielding antibunching of light, and the expressions of the Wigner functions for all investigated punctured states. Finally, we propose some possible experimental realizations of such states.

  20. A Kinect™ camera based navigation system for percutaneous abdominal puncture

    NASA Astrophysics Data System (ADS)

    Xiao, Deqiang; Luo, Huoling; Jia, Fucang; Zhang, Yanfang; Li, Yong; Guo, Xuejun; Cai, Wei; Fang, Chihua; Fan, Yingfang; Zheng, Huimin; Hu, Qingmao

    2016-08-01

    Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect™ was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect™. For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect™ depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator’s skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect™ for Windows version 2 (Kinect™ V2). The target registration error (TRE), user error, and TPE are 4.26  ±  1.94 mm, 2.92  ±  1.67 mm, and 5.23  ±  2.29 mm, respectively. No statistically significant differences in TPE regarding operator’s skill and trajectory are observed. Additionally, a Kinect™ for Windows version 1 (Kinect™ V1) was tested with 12 insertions, and the TRE evaluated with the Kinect™ V1 is statistically significantly larger than that with the Kinect™ V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40  ±  2.72 mm, and its lateral and longitudinal component were 4.30  ±  2.51 mm and 3.80  ±  3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect™-based navigation is superior to the first-generation Kinect™, and has potential of clinical application in percutaneous abdominal puncture.

  1. Assessment of Intervertebral Disc Degeneration Based on Quantitative MRI Analysis: an in vivo study

    PubMed Central

    Grunert, Peter; Hudson, Katherine D.; Macielak, Michael R.; Aronowitz, Eric; Borde, Brandon H.; Alimi, Marjan; Njoku, Innocent; Ballon, Douglas; Tsiouris, Apostolos John; Bonassar, Lawrence J.; Härtl, Roger

    2015-01-01

    Study design Animal experimental study Objective To evaluate a novel quantitative imaging technique for assessing disc degeneration. Summary of Background Data T2-relaxation time (T2-RT) measurements have been used to quantitatively assess disc degeneration. T2 values correlate with the water content of inter vertebral disc tissue and thereby allow for the indirect measurement of nucleus pulposus (NP) hydration. Methods We developed an algorithm to subtract out MRI voxels not representing NP tissue based on T2-RT values. Filtered NP voxels were used to measure nuclear size by their amount and nuclear hydration by their mean T2-RT. This technique was applied to 24 rat-tail intervertebral discs’ (IVDs), which had been punctured with an 18-gauge needle according to different techniques to induce varying degrees of degeneration. NP voxel count and average T2-RT were used as parameters to assess the degeneration process at 1 and 3 months post puncture. NP voxel counts were evaluated against X-ray disc height measurements and qualitative MRI studies based on the Pfirrmann grading system. Tails were collected for histology to correlate NP voxel counts to histological disc degeneration grades and to NP cross-sectional area measurements. Results NP voxel count measurements showed strong correlations to qualitative MRI analyses (R2=0.79, p<0.0001), histological degeneration grades (R2=0.902, p<0.0001) and histological NP cross-sectional area measurements (R2=0.887, p<0.0001). In contrast to NP voxel counts, the mean T2-RT for each punctured group remained constant between months 1 and 3. The mean T2-RTs for the punctured groups did not show a statistically significant difference from those of healthy IVDs (63.55ms ±5.88ms month 1 and 62.61ms ±5.02ms) at either time point. Conclusion The NP voxel count proved to be a valid parameter to quantitatively assess disc degeneration in a needle puncture model. The mean NP T2-RT does not change significantly in needle-puncture induced degenerated IVDs. IVDs can be segmented into different tissue components according to their innate T2-RT. PMID:24384655

  2. Endovascular Crossing of Chronic Total Occlusions Using an Impulse: An Explorative Design Study.

    PubMed

    Sakes, Aimée; van der Wiel, Marleen; Dodou, Dimitra; Breedveld, Paul

    2017-06-01

    In this study we investigated whether exerting an impulse on a Chronic Total Occlusion (CTO) improves the success rate of CTO crossing as compared to the currently used method of statically pushing the guidewire against the CTO. A prototype (Ø2 mm) was developed that generates translational momentum using a spring-loaded indenter and converts it to an impulse during impact. Mechanical performance was evaluated by measuring the peak force and momentum for different spring compressions and strike distances in air and blood-mimicking fluid. Puncture performance, in terms of number of punctures, number of strikes to puncture, and energy transfer from the indenter to the CTO, was assessed for six tip shapes (stamp, wedge, spherical, pointed, hollow spherical, and ringed) on three CTO models with different weight percentages of gelatin and calcium. As a control, a Ø0.4 mm rigid rod was tested. A maximum indenter momentum of 1.3 mNs (velocity of 3.4 m/s), a peak force of 19.2 N (vs. 1.5 N reported in literature and 2.7 N for the control), and CTO displacement of 1.4 mm (vs. 2.7 mm for the control) were measured. The spherical and ringed tips were most effective, with on average 2.3 strikes to puncture the most calcified CTO model. The prototype generated sufficient peak forces to puncture highly calcified CTO models, which are considered most difficult to cross during PCI. Furthermore, CTO displacement was minimized, resulting in a more effective procedure. In future, a smaller, faster, and flexible clinical prototype will be developed.

  3. Pressures of Wilderness Improvised Wound Irrigation Techniques: How Do They Compare?

    PubMed

    Luck, John B; Campagne, Danielle; Falcón Banchs, Roberto; Montoya, Jason; Spano, Susanne J

    2016-12-01

    Compare the pressures measured by improvised irrigation techniques to a commercial device and to prior reports. Devices tested included a commercial 500-mL compressible plastic bottle with splash guard, a 10-mL syringe, a 10-mL syringe with a 14-ga angiocatheter (with needle removed), a 50-mL Sawyer syringe, a plastic bag punctured with a 14-ga needle, a plastic bottle with cap punctured by a 14-ga needle, a plastic bottle with sports top, and a bladder-style hydration system. Each device was leveled on a support, manually compressed, and aimed toward a piece of glass. A high-speed camera placed behind the glass recorded the height of the stream upon impact at its highest and lowest point. Measurements were recorded 5 times for each device. Pressures in pounds per square inch (psi) were calculated. The syringe and angiocatheter pressures measured the highest pressures (16-49 psi). The 50-mL syringe (7-11 psi), 14-ga punctured water bottle (7-25 psi), and water bottle with sports top (3-7 psi) all measured at or above the commercial device (4-5 psi). Only the bladder-style hydration system (1-2 psi) and plastic bag with 14-ga needle puncture (2-3 psi) did not reach pressures generated by the commercial device. Pressures are consistent with those previously reported. All systems using compressible water bottles and all syringe-based systems provided pressures at or exceeding a commercial wound irrigation device. A 14-ga punctured plastic bag and bladder-style hydration pack failed to generate similar irrigation pressures. Copyright © 2016 Wilderness Medical Society. All rights reserved.

  4. Effect of Survivin gene therapy via lentivirus vector on the course of intervertebral disc degeneration in an in vivo rabbit model.

    PubMed

    Yue, Bin; Lin, Yazhou; Ma, Xuexiao; Zhang, Guoqing; Chen, Bohua

    2016-11-01

    The aim of the current study was to use gene therapy to attenuate or reverse the degenerative process within the intervertabral disc. The effect of survivin gene therapy via lentiviral vector transfection on the course of intervertebral disc degeneration was investigated in the current study in an in vivo rabbit model. A total of 15 skeletally mature female New Zealand White rabbits were randomly divided into three groups: Punctured blank control group (group A, n=5), punctured empty vector control group (group B, n=5) and the treatment group (group C, n=5). Computed tomography‑guided puncture was performed at the L3‑L4 and L4‑L5 discs, in accordance with a previously validated rabbit annulotomy model for intervertebral disc degeneration. After 3 weeks, a lentiviral vector (LV) carrying survivin was injected into the nucleus pulposus. The results demonstrated that through magnetic resonance imaging, histology, gene expression, protein content and apoptosis analyses, group A and B were observed to exhibit disc degeneration, which increased over time, and no significant difference was observed between the two groups (P>0.05). However, there was reduced disc degeneration in group C compared with the punctured control groups, and the difference was statistically significant (P<0.05). Overall, the results of the present study demonstrated that injection of the LV carrying survivin into punctured rabbit intervertebral discs acted to delay changes associated with the degeneration of the discs. Although data from animal models should be extrapolated to the human condition with caution, the present study suggests potential for the use of gene therapy to decelerate disc degeneration.

  5. Starclose SE® hemostasis after 6F direct antegrade superficial femoral artery access distal to the femoral head for peripheral endovascular procedures in obese patients.

    PubMed

    Spiliopoulos, Stavros; Kitrou, Panagiotis; Christeas, Nikolaos; Karnabatidis, Dimitris

    2016-01-01

    Direct superficial femoral artery (SFA) antegrade puncture is a valid alternative to common femoral artery (CFA) access for peripheral vascular interventions. Data investigating vascular closure device (VCD) hemostasis of distant SFA 6F access are limited. We aimed to investigate the safety and effectiveness of the Starclose SE® VCD for hemostasis, following direct 6F antegrade SFA access distal to the femoral head. This prospective, single-center study included patients who were not suitable for CFA puncture and were scheduled to undergo peripheral endovascular interventions using direct antegrade SFA 6F access, at least 2 cm below the inferior edge of femoral head. Hemostasis was obtained with the Starclose SE® VCD (Abbott Laboratories). Primary endpoints were successful hemostasis rate and periprocedural (30-day) major complication rate. Secondary endpoint was the rate of minor complications. Clinical and Doppler ultrasound follow-up was performed at discharge and at one month. Between September 2014 and August 2015, a total of 30 patients (21 male; 70.0%) with a mean body mass index of 41.2 kg/m2 were enrolled. Mean age was 72±9 years (range, 67-88 years). Most patients suffered from critical limb ischemia (87.1%) and diabetes (61.3%). Calcifications were present in eight cases (26.6%). Reason for direct SFA puncture was obesity (100%). Successful hemostasis was achieved in 100% of the cases. No major complications were noted after one-month follow-up. Minor complications included two <5 cm hematomas (6.6%) not necessitating treatment. In this prospective study, Starclose SE® VCD was safe and effective for hemostasis of antegrade direct SFA puncture. Uncomplicated hemostasis was achieved even in cases of puncturing 2 to 7 cm below the inferior edge of the femoral head.

  6. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  7. Venous access and long-term pacemaker lead failure: comparing contrast-guided axillary vein puncture with subclavian puncture and cephalic cutdown.

    PubMed

    Chan, Ngai-Yin; Kwong, Nim-Pong; Cheong, Adrian-Piers

    2017-07-01

    Existing data on the relationship between venous access and long-term pacemaker lead failure (PLF) are scarce and inconsistent. We aim to study the hypothesis that contrast-guided axillary vein puncture (AP) is better than subclavian puncture (SP) and similar to cephalic vein cutdown (CV) in the incidence of PLF and the success rate of AP is higher than CV. The case records of 409 patients with 681 implantable pacemaker leads were reviewed. Two hundred and fifty-two, 217, and 212 leads were implanted via AP, CV, and SP, respectively. With a mean follow-up of 73.6 ± 33.1 months, 20 (2.9%) PLF occurred. Three (1.2%), 5 (2.3%), and 12 (5.6%) PLF occurred in the AP, CV, and SP groups, respectively. On multivariate Cox regression analysis, the only independent predictor for PLF was the use of SP instead of AP (AP vs. SP; hazard ratio: 0.261; 95% confidence interval: 0.071-0.954, P = 0.042). The success rate of CV (78.2%) was significantly lower than those of AP (97.6%) and SP (96.8%) (P < 0.001). Compared with SP, the use of AP but not CV independently predicted a lower risk of PLF. The success rates in achieving venous accesses were similar between AP and SP, but significantly lower for CV. Axillary vein puncture may thus be considered the venous access of choice for pacemaker lead implantation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  8. [Comparative study of 3 types of lancets for performing prick tests].

    PubMed

    Montalvo, A; Martín, S; Mesa, A; Cortés, C; Rodríguez, M; Laso, M T

    1996-01-01

    Skin Prick Test is considered the cutaneous test of choice in rutinary clinical practice as well as in research. In the last 15 years a large number of lancets for puncture test have been developed looking for a higher level of standardisation and reproducibility. We have compared three lancets, two of them, NeoAbelló (NA) and Dome/Hollister Stier (DHS), used in puncture test and a third one, Blood Lancet (BL), in the modified prick test. Twenty-two patients sensitised to Phleum pratense were tested with the three lancets at three extract concentrations and histamine 10 mg/mL in duplicate. We compared their wheal sizes by means of parallel line assay, their reproducibility, frequency of bleeding wheals, the disturbance for the patient and the correlation between specific IgE and skin response. Wheal size was similar for puncture tests (DHS and NA lancets) and significatively lower than BL, being necessary to increase 1.9 times the extract concentration when using DHS and NA lancets to achieve the same wheal size than when using BL lancets (p < 0.01). Reproducibility with histamine was similar with the three lancets while with the extract was somehow better with puncture tests but without statistical significance. Bleeding was significantly more frequent with BL although this did not influence the results. Less pain was obtained with BL. Finally, correlation with specific IgE was slightly significant for NA and very similar for the other two. With these results in mind we think that any of the three lancets is valid for the diagnostic of the allergic patient. Nevertheless, puncture tests are probably the most suitable at a research level.

  9. Self-force via m-mode regularization and 2+1D evolution: Foundations and a scalar-field implementation on Schwarzschild spacetime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolan, Sam R.; Barack, Leor

    2011-01-15

    To model the radiative evolution of extreme mass-ratio binary inspirals (a key target of the LISA mission), the community needs efficient methods for computation of the gravitational self-force (SF) on the Kerr spacetime. Here we further develop a practical 'm-mode regularization' scheme for SF calculations, and give the details of a first implementation. The key steps in the method are (i) removal of a singular part of the perturbation field with a suitable 'puncture' to leave a sufficiently regular residual within a finite worldtube surrounding the particle's worldline, (ii) decomposition in azimuthal (m) modes, (iii) numerical evolution of the mmore » modes in 2+1D with a finite-difference scheme, and (iv) reconstruction of the SF from the mode sum. The method relies on a judicious choice of puncture, based on the Detweiler-Whiting decomposition. We give a working definition for the ''order'' of the puncture, and show how it determines the convergence rate of the m-mode sum. The dissipative piece of the SF displays an exponentially convergent mode sum, while the m-mode sum for the conservative piece converges with a power law. In the latter case, the individual modal contributions fall off at large m as m{sup -n} for even n and as m{sup -n+1} for odd n, where n is the puncture order. We describe an m-mode implementation with a 4th-order puncture to compute the scalar-field SF along circular geodesics on Schwarzschild. In a forthcoming companion paper we extend the calculation to the Kerr spacetime.« less

  10. Physiological and Pathological Impact of Blood Sampling by Retro-Bulbar Sinus Puncture and Facial Vein Phlebotomy in Laboratory Mice

    PubMed Central

    Holst, Birgitte; Hau, Jann; Rozell, Björn; Abelson, Klas Stig Peter

    2014-01-01

    Retro-bulbar sinus puncture and facial vein phlebotomy are two widely used methods for blood sampling in laboratory mice. However, the animal welfare implications associated with these techniques are currently debated, and the possible physiological and pathological implications of blood sampling using these methods have been sparsely investigated. Therefore, this study was conducted to assess and compare the impacts of blood sampling by retro-bulbar sinus puncture and facial vein phlebotomy. Blood was obtained from either the retro-bulbar sinus or the facial vein from male C57BL/6J mice at two time points, and the samples were analyzed for plasma corticosterone. Body weights were measured at the day of blood sampling and the day after blood sampling, and the food consumption was recorded automatically during the 24 hours post-procedure. At the end of study, cheeks and orbital regions were collected for histopathological analysis to assess the degree of tissue trauma. Mice subjected to facial vein phlebotomy had significantly elevated plasma corticosterone levels at both time points in contrast to mice subjected to retro-bulbar sinus puncture, which did not. Both groups of sampled mice lost weight following blood sampling, but the body weight loss was higher in mice subjected to facial vein phlebotomy. The food consumption was not significantly different between the two groups. At gross necropsy, subcutaneous hematomas were found in both groups and the histopathological analyses revealed extensive tissue trauma after both facial vein phlebotomy and retro-bulbar sinus puncture. This study demonstrates that both blood sampling methods have a considerable impact on the animals' physiological condition, which should be considered whenever blood samples are obtained. PMID:25426941

  11. Investigation of Near Shannon Limit Coding Schemes

    NASA Technical Reports Server (NTRS)

    Kwatra, S. C.; Kim, J.; Mo, Fan

    1999-01-01

    Turbo codes can deliver performance that is very close to the Shannon limit. This report investigates algorithms for convolutional turbo codes and block turbo codes. Both coding schemes can achieve performance near Shannon limit. The performance of the schemes is obtained using computer simulations. There are three sections in this report. First section is the introduction. The fundamental knowledge about coding, block coding and convolutional coding is discussed. In the second section, the basic concepts of convolutional turbo codes are introduced and the performance of turbo codes, especially high rate turbo codes, is provided from the simulation results. After introducing all the parameters that help turbo codes achieve such a good performance, it is concluded that output weight distribution should be the main consideration in designing turbo codes. Based on the output weight distribution, the performance bounds for turbo codes are given. Then, the relationships between the output weight distribution and the factors like generator polynomial, interleaver and puncturing pattern are examined. The criterion for the best selection of system components is provided. The puncturing pattern algorithm is discussed in detail. Different puncturing patterns are compared for each high rate. For most of the high rate codes, the puncturing pattern does not show any significant effect on the code performance if pseudo - random interleaver is used in the system. For some special rate codes with poor performance, an alternative puncturing algorithm is designed which restores their performance close to the Shannon limit. Finally, in section three, for iterative decoding of block codes, the method of building trellis for block codes, the structure of the iterative decoding system and the calculation of extrinsic values are discussed.

  12. Complications of fluoroscopically directed facet joint nerve blocks: a prospective evaluation of 7,500 episodes with 43,000 nerve blocks.

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Fellows, Bert

    2012-01-01

    Chronic spinal pain is common along with numerous modalities of diagnostic and therapeutic interventions utilized, creating a health care crisis. Facet joint injections and epidural injections are the 2 most commonly utilized interventions in managing chronic spinal pain. While the literature addressing the effectiveness of facet joint nerve blocks is variable and emerging, there is paucity of literature on adverse effects of facet joint nerve blocks. A prospective, non-randomized study of patients undergoing interventional techniques from May 2008 to December 2009. A private interventional pain management practice, a specialty referral center in the United States. Investigation of the incidence in characteristics of adverse effects and complications of facet joint nerve blocks. The study was carried out over a period of 20 months including almost 7,500 episodes of 43,000 facet joint nerve blocks with 3,370 episodes in the cervical region, 3,162 in the lumbar region, and 950 in the thoracic region. All facet joint nerve blocks were performed under fluoroscopic guidance in an ambulatory surgery center by 3 physicians. The complications encountered during the procedure and postoperatively were evaluated prospectively. This study was carried out over a period of 20 months and included over 7,500 episodes or 43,000 facet joint nerve blocks. All of the interventions were performed under fluoroscopic guidance in an ambulatory surgery center by one of 3 physicians. The complications encountered during the procedure and postoperatively were prospectively evaluated. Measurable outcomes employed were intravascular entry of the needle, profuse bleeding, local hematoma, dural puncture and headache, nerve root or spinal cord irritation with resultant injury, and infectious complications. There were no major complications. Multiple side effects and complications observed included overall intravascular penetration in 11.4% of episodes with 20% in cervical region, 4% in lumbar region, and 6% in thoracic region; local bleeding in 76.3% of episodes with highest in thoracic region and lowest in cervical region; oozing with 19.6% encounters with highest in cervical region and lowest in lumbar region; with local hematoma seen only in 1.2% of the patients with profuse bleeding, bruising, soreness, nerve root irritation, and all other effects such as vasovagal reactions observed in 1% or less of the episodes. Limitations of this study include lack of contrast injection, use of intermittent fluoroscopy and also an observational nature of the study. This study illustrate that major complications are extremely rare and minor side effects are common.

  13. Lessons we learn from review of urological procedures performed during three decades in a spinal cord injury patient: a case report

    PubMed Central

    2009-01-01

    Background We review urological procedures performed on a spinal cord injury patient during three decades. Case presentation A 23-year-old male patient sustained T-12 paraplegia in 1971. In 1972, intravenous urography showed both kidneys functioning well; division of external urethral sphincter was performed. In 1976, reimplantation of left ureter (Lich-Gregoir) was carried out for vesicoureteric reflux. As reflux persisted, left ureter was reimplanted by psoas hitch-Boari flap technique in 1978. This patient suffered from severe pain in legs; intrathecal injection of phenol was performed twice in 1979. The segment bearing the scarred spinal cord was removed in September 1982. This patient required continuous catheter drainage. Deep median sphincterotomy was performed in 1984. As the left kidney showed little function, left nephroureterectomy was performed in 1986. In an attempt to obviate the need for an indwelling catheter, bladder neck resection and tri-radiate sphincterotomy were carried out in 1989; but these procedures proved futile. UroLume prosthesis was inserted and splinted the urethra from prostatic apex to bulb in October 1990. As mucosa was apposing distal to stent, in November 1990, second UroLume stent was hitched inside distal end of first. In March 1991, urethroscopy showed the distal end of the distal stent had fragmented; loose wires were removed. In April 1991, this patient developed sweating, shivering and haematuria. Urine showed Pseudomonas. Suprapubic cystostomy was performed. Suprapubic cystostomy was done again the next day, as the catheter was pulled out accidentally during night. Subsequently, a 16 Fr Silastic catheter was passed per urethra and suprapubic catheter was removed. In July 1993, Urocoil stent was put inside UroLume stent with distal end of Urocoil stent lying free in urethra. In September 1993, this patient was struggling to pass urine. Urocoil stent had migrated to bladder; therefore, Urocoil stent was removed and a Memotherm stent was deployed. This patient continued to experience trouble with micturition; therefore, Memotherm stent was removed. Currently, wires of UroLume stent protrude in to urethra, which tend to puncture the balloon of urethral Foley catheter, especially when the patient performs manual evacuation of bowels. Conclusion We failed to implement intermittent catheterisation along with anti-cholinergic therapy. Instead, we performed several urological procedures with unsatisfactory outcome; the patient lost his left kidney. We believe that honest review of clinical practice will help towards learning from past mistakes. PMID:20062593

  14. Lessons we learn from review of urological procedures performed during three decades in a spinal cord injury patient: a case report.

    PubMed

    Vaidyanathan, Subramanian; Soni, Bakul M; Hughes, Peter L; Singh, Gurpreet; Mansour, Paul; Oo, Tun

    2009-12-16

    We review urological procedures performed on a spinal cord injury patient during three decades. A 23-year-old male patient sustained T-12 paraplegia in 1971. In 1972, intravenous urography showed both kidneys functioning well; division of external urethral sphincter was performed. In 1976, reimplantation of left ureter (Lich-Gregoir) was carried out for vesicoureteric reflux. As reflux persisted, left ureter was reimplanted by psoas hitch-Boari flap technique in 1978. This patient suffered from severe pain in legs; intrathecal injection of phenol was performed twice in 1979. The segment bearing the scarred spinal cord was removed in September 1982. This patient required continuous catheter drainage. Deep median sphincterotomy was performed in 1984. As the left kidney showed little function, left nephroureterectomy was performed in 1986. In an attempt to obviate the need for an indwelling catheter, bladder neck resection and tri-radiate sphincterotomy were carried out in 1989; but these procedures proved futile. UroLume prosthesis was inserted and splinted the urethra from prostatic apex to bulb in October 1990. As mucosa was apposing distal to stent, in November 1990, second UroLume stent was hitched inside distal end of first. In March 1991, urethroscopy showed the distal end of the distal stent had fragmented; loose wires were removed. In April 1991, this patient developed sweating, shivering and haematuria. Urine showed Pseudomonas. Suprapubic cystostomy was performed. Suprapubic cystostomy was done again the next day, as the catheter was pulled out accidentally during night. Subsequently, a 16 Fr Silastic catheter was passed per urethra and suprapubic catheter was removed. In July 1993, Urocoil stent was put inside UroLume stent with distal end of Urocoil stent lying free in urethra. In September 1993, this patient was struggling to pass urine. Urocoil stent had migrated to bladder; therefore, Urocoil stent was removed and a Memotherm stent was deployed. This patient continued to experience trouble with micturition; therefore, Memotherm stent was removed. Currently, wires of UroLume stent protrude in to urethra, which tend to puncture the balloon of urethral Foley catheter, especially when the patient performs manual evacuation of bowels. We failed to implement intermittent catheterisation along with anti-cholinergic therapy. Instead, we performed several urological procedures with unsatisfactory outcome; the patient lost his left kidney. We believe that honest review of clinical practice will help towards learning from past mistakes.

  15. Management of obstructed balloon catheters.

    PubMed Central

    Browning, G G; Barr, L; Horsburgh, A G

    1984-01-01

    Failure of a balloon catheter to deflate is not uncommon and prevents its removal. Methods of overcoming the problem include traction, bursting the balloon by overinflation, dissolving it with solvents, puncturing it percutaneously with a needle, or puncturing it with a wire stylet passed through the catheter. All except the last technique have major disadvantages and are of questionable safety. Transcatheter puncture of the balloon was used in 16 patients to remove obstructed balloon catheters without any technical difficulty, distress to the patient, or complication. The procedure is safe, simple, and does not require an anaesthetic. If necessary it could be performed safely by nursing or paramedical staff without the patient having to be admitted to hospital. It is the method of choice for the management of this problem. Images FIG 1 FIG 2 FIG 3 FIG 4 PMID:6428691

  16. A new surgical technique for medial collateral ligament balancing: multiple needle puncturing.

    PubMed

    Bellemans, Johan; Vandenneucker, Hilde; Van Lauwe, Johan; Victor, Jan

    2010-10-01

    In this article, we present our experience with a new technique for medial soft tissue balancing, where we make multiple punctures in the medial collateral ligament (MCL) using a 19-gauge needle, to progressively stretch the MCL until a correct ligament balance is achieved. Ligament status was evaluated both before and after the procedure using computer navigation and mediolateral stress testing. The procedure was considered successful when 2 to 4-mm mediolateral joint line opening was obtained in extension and 2 to 6 mm in flexion. In 34 of 35 cases, a progressive correction of medial tightness was achieved according to the above described criteria. One case was considered overreleased in extension. Needle puncturing is a new, effective, and safe technique for progressive correction of MCL tightness in the varus knee. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. [Injuries to blood vessels near the heart caused by central venous catheters].

    PubMed

    Abram, J; Klocker, J; Innerhofer-Pompernigg, N; Mittermayr, M; Freund, M C; Gravenstein, N; Wenzel, V

    2016-11-01

    Injuries to blood vessels near the heart can quickly become life-threatening and include arterial injuries during central venous puncture, which can lead to hemorrhagic shock. We report 6 patients in whom injury to the subclavian artery and vein led to life-threatening complications. Central venous catheters are associated with a multitude of risks, such as venous thrombosis, air embolism, systemic or local infections, paresthesia, hemothorax, pneumothorax, and cervical hematoma, which are not always immediately discernible. The subclavian catheter is at a somewhat lower risk of catheter-associated sepsis and symptomatic venous thrombosis than approaches via the internal jugular and femoral veins. Indeed, access via the subclavian vein carries a substantial risk of pneumo- and hemothorax. Damage to the subclavian vein or artery can also occur during deliberate and inadvertent punctures and result in life-threatening complications. Therefore, careful consideration of the access route is required in relation to the patient and the clinical situation, to keep the incidence of complications as low as possible. For catheterization of the subclavian vein, puncture of the axillary vein in the infraclavicular fossa is a good alternative, because ultrasound imaging of the target vessel is easier than in the subclavian vein and the puncture can be performed much further from the lung.

  18. Comparison of techniques for transdiaphragmatic thoracic drainage after diaphragmatic defect closure in dogs: a cadaveric study

    PubMed Central

    Yoon, Hun-Young; Mann, F. A.; Lee, Suhwon

    2013-01-01

    Four thoracic evacuation techniques for pneumothorax elimination after diaphragmatic defect closure were compared in 40 canine cadavers. After creating a defect in the left side of the diaphragm, thoracic drainage was performed by thoracostomy tube insertion through the defect and a small (DD-SP) or large (DD-LP) puncture created in the caudal mediastinum, or through both the diaphragmatic defect and intact contralateral diaphragm with a small (DI-SP) or large (DI-LP) puncture in made in the caudal mediastinum. Differences in intrapleural pressure (IPP) between the right and left hemithoraxes after air evacuation along with differences in IPP before making a defect and after air evacuation in each hemithorax were calculated. A difference (p ≤ 0.0011) in IPP between the left and right hemithoraxes after air evacuation as well as before making a defect and after air evacuation in the right hemithorax was detected for the DD-SP group. No significant differences (p ≥ 0.0835) were observed for the DI-LP, DD-LP, or DI-SP groups. Creation of a large mediastinal puncture or thoracic evacuation through both a diaphragmatic defect and intact contralateral diaphragm can facilitate proper pneumothorax elimination bilaterally after diaphragmatic defect closure in dogs with a small puncture in the caudal mediastinum. PMID:23814472

  19. Influence of Puncture Site on Radial Artery Occlusion After Transradial Coronary Intervention.

    PubMed

    Bi, Xi-Le; Fu, Xiang-Hua; Gu, Xin-Shun; Wang, Yan-Bo; Li, Wei; Wei, Li-Ye; Fan, Yan-Ming; Bai, Shi-Ru

    2016-04-20

    The risk of radial artery occlusion (RAO) needs particular attention in transradial intervention (TRI). Therefore, reducing vascular occlusion has an important clinical significance. The aim of this study was to determine the appropriate puncture site during TRI through comparing the occurrence of RAO between the different puncture sites to reduce the occurrence of RAO after TRI. We prospectively assessed the occurrence of RAO in 606 consecutive patients undergoing TRI. Artery occlusion was evaluated with Doppler ultrasound in 2 days and 1 year after the intervention. Risk factors for RAO were evaluated using a multivariate model analysis. Of the 606 patients, the RAO occurred in 56 patients. Compared with TRI at 2-5 cm away from the radius styloid process, the odds ratio (OR) for occlusion risk at 0 cm and 1 cm were 9.65 (P = 0.033) and 8.90 (P = 0.040), respectively. The RAO occurred in the ratio of the arterial diameter to the sheath diameter ≤1 (OR = 2.45, P = 0.004). Distal puncture sites (0-1 cm away from the radius styloid process) can lead to a higher rate of RAO. ClinicalTrials.gov, NCT01979627; https://clinicaltrials.gov/ct2/show/NCT01979627?term = NCT01979627 and rank = 1.

  20. Direct puncture embolization of the internal iliac artery during cesarean delivery for pernicious placenta previa coexisting with placenta accreta.

    PubMed

    Chen, Zhenyu; Li, Ju; Shen, Jian; Jin, Jiaxi; Zhang, Wei; Zhong, Wan

    2016-12-01

    To evaluate direct puncture embolization of the internal iliac artery with hemostatic gelatin sponge particles to treat pernicious placenta previa coexisting with placenta accreta during cesarean delivery. A retrospective study was conducted of data from women with pernicious placenta previa and placenta accreta who underwent direct puncture embolization of the internal iliac artery during cesarean delivery at a center in China between September 1, 2013, and February 28, 2015. Information regarding surgical procedures, operative data, and outcomes during hospitalization were obtained from medical records. The procedure was successful in all 16 cases included. Mean operative time was 78 minutes (range 65-90) and mean estimated blood loss was 1550 mL (range 1000-2500). Complications such as fever, buttock pain, or acute limb ischemia were not observed. The procedure was performed after partial cystectomy for two patients with bladder invasion. Postoperative Doppler imaging indicated uterine recovery and normalized uterine blood flow in all patients. Direct puncture embolization of the internal iliac artery during cesarean delivery was a safe, effective, simple, and rapid method to control hemorrhage among women with pernicious placenta previa and placenta accreta. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  1. Comparison of Ultrasonography-Guided Central Venous Catheterization Between Adult and Pediatric Populations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tercan, Fahri; Oguzkurt, Levent; Ozkan, Ugur

    2008-05-15

    The purpose of this study was to compare the technical success and complication rates of ultrasonography-guided central venous catheterization between adult and pediatric patients which have not been reported previously. In a 4-year period, 859 ultrasonography-guided central vein catheterizations in 688 adult patients and 247 catheterizations in 156 pediatric patients were retrospectively evaluated. Mean age was 56.3 years (range, 18 to 95 years) for adults and 3.3 years (range, 0.1 to 16.3 years) for children. The preferred catheterization site was internal jugular vein in 97% of adults and 85% of children. The technical success rate, mean number of punctures, andmore » rate of single wall puncture were 99.4%, 1.04 (range, 1-3), and 83% for adults and 90.3%, 1.25 (range, 1-5), and 49% for children, respectively. All the differences were statistically significant (p < 0.05). Complication rates were 2.3% and 2.4% for adults and children, respectively (p > 0.05). Major complications such as pneumothorax and hemothorax were not seen in any group. In conclusion, ultrasonography-guided central venous catheterization has a high technical success rate, lower puncture attempt rate, and higher single wall puncture rate in adults compared to children. Complication rates are comparable in the two groups.« less

  2. Simultaneous Antegrade-Retrograde Subintimal Revascularization of a Femoropopliteal Chronic Total Occlusion by a Reentry Device-Facilitated Puncture of a Retrogradely Inserted Balloon.

    PubMed

    Goltz, Jan Peter; Anton, Susanne; Wiedner, Marcus; Barkhausen, Jörg; Stahlberg, Erik

    2017-08-01

    To report a rendezvous technique for subintimal revascularization of a chronic total occlusion (CTO) of the superficial femoral artery (SFA). This maneuver is appropriate after failure to cross a long SFA CTO via intra- and subintimal approaches from the ipsilateral femoral as well as retrograde posterior tibial artery (PTA) access sites. After predilation of the subintimal space from the femoral access, a reentry device was placed at the level of the first popliteal artery segment. A balloon was delivered via the retrograde PTA access and inflated at the corresponding level of the reentry device. The balloon was punctured with the needle of the reentry device under fluoroscopic control, and a 0.014-inch guidewire was placed within the punctured balloon. The balloon and the antegrade guidewire were retracted from the retrograde access while the guidewire was gently pushed from the femoral site. Conventional balloon angioplasty of the SFA occlusion was performed via the femoral access, followed by overlapping stent-graft implantation. Complete revascularization of the CTO was documented. In selected cases a transfemoral reentry device-assisted puncture of a retrogradely inserted balloon within the subintimal space may facilitate a rendezvous and revascularization if standard techniques to cross long CTOs have failed.

  3. Spread Spectrum Visual Sensor Network Resource Management Using an End-to-End Cross-Layer Design

    DTIC Science & Technology

    2011-02-01

    Coding In this work, we use rate compatible punctured convolutional (RCPC) codes for channel coding [11]. Using RCPC codes al- lows us to utilize Viterbi’s...11] J. Hagenauer, “ Rate - compatible punctured convolutional codes (RCPC codes ) and their applications,” IEEE Trans. Commun., vol. 36, no. 4, pp. 389...source coding rate , a channel coding rate , and a power level to all nodes in the

  4. A case of transgastric gallbladder puncture as a complication during endoscopic ultrasound-guided drainage of a pancreatic pseudocyst.

    PubMed

    Hikichi, Takuto; Irisawa, Atsushi; Takagi, Tadayuki; Shibukawa, Goro; Wakatsuki, Takeru; Imamura, Hidemichi; Takahashi, Yuta; Sato, Ai; Sato, Masaki; Oyama, Hitoshi; Sato, Naoto; Yamamoto, Go; Mokonuma, Tatsuyuki; Obara, Katsutoshi; Ohira, Hiromasa

    2007-06-01

    A 43-year-old man, a regular drinker, developed a pseudocyst in the pancreatic tail as a result of acutely worsening chronic pancreatitis. Because the pseudocyst, 10 cm in diameter, did not disappear despite conservative treatment, an internal drainage stent was placed transgastrically under endoscopic ultrasound (EUS) guidance. However, cyst infection occurred, and EUS-guided drainage was performed, when the gallbladder was punctured inadvertently. Immediately a nasocystic drain was placed in the gallbladder. Owing to this timely measure, only mild and localized peritonitis developed. Conservative treatment with fasting and an antibiotic was administered, and peritonitis subsided quickly. On the same day, another nasocystic drain was placed for the pancreatic pseudocyst, and it disappeared. As far as we know, this is the first case in which gallbladder puncture was inadvertently performed during EUS-guided drainage of a pancreatic pseudocyst.

  5. Secret information reconciliation based on punctured low-density parity-check codes for continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Jiang, Xue-Qin; Huang, Peng; Huang, Duan; Lin, Dakai; Zeng, Guihua

    2017-02-01

    Achieving information theoretic security with practical complexity is of great interest to continuous-variable quantum key distribution in the postprocessing procedure. In this paper, we propose a reconciliation scheme based on the punctured low-density parity-check (LDPC) codes. Compared to the well-known multidimensional reconciliation scheme, the present scheme has lower time complexity. Especially when the chosen punctured LDPC code achieves the Shannon capacity, the proposed reconciliation scheme can remove the information that has been leaked to an eavesdropper in the quantum transmission phase. Therefore, there is no information leaked to the eavesdropper after the reconciliation stage. This indicates that the privacy amplification algorithm of the postprocessing procedure is no more needed after the reconciliation process. These features lead to a higher secret key rate, optimal performance, and availability for the involved quantum key distribution scheme.

  6. Combined Angio-Seal™ and stenting rescue treatment in a case of iatrogenic common carotid artery dissection during direct puncture for ruptured intracranial aneurysm embolization: a technical note.

    PubMed

    Iosif, Christina; Clarençon, Frédéric; Di Maria, Federico; Law-Ye, Bruno; Le Jean, Lise; Capelle, Laurent; Chiras, Jacques; Sourour, Nader

    2013-05-01

    Direct puncture may offer an alternative access for embolization of intracranial aneurysms in patients presenting with tortuous vessels. Nevertheless, major complications such as compressive hematoma and arterial dissection can occur with this technique. A tight common carotid artery (CCA) dissection was seen secondary to direct puncture in a 72-year-old patient who presented with a ruptured anterior communicating artery (ACom) aneurysm. After regular coiling of the aneurysm and using a femoral approach, an Angio-Seal™ device (St Jude Medical, Saint Paul, MN, USA) was placed and a carotid wallstent (Stryker Neurovascular, Fremont, CA, USA) successfully deployed at the dissected CCA, which was followed by good clinical and angiographic outcomes. A combined rescue technique combining Angio-Seal insertion and stent deployment was safe and effective for managing iatrogenic carotid artery dissection. Copyright © 2013. Published by Elsevier Masson SAS.

  7. Bowen-York trumpet data and black-hole simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannam, Mark; Murchadha, Niall O; Husa, Sascha

    2009-12-15

    The most popular method to construct initial data for black-hole-binary simulations is the puncture method, in which compactified wormholes are given linear and angular momentum via the Bowen-York extrinsic curvature. When these data are evolved, they quickly approach a trumpet topology, suggesting that it would be preferable to use data that are in trumpet form from the outset. To achieve this, we extend the puncture method to allow the construction of Bowen-York trumpets, including an outline of an existence and uniqueness proof of the solutions. We construct boosted, spinning and binary Bowen-York puncture trumpets using a single-domain pseudospectral elliptic solver,more » and evolve the binary data and compare with standard wormhole-data results. We also show that for boosted trumpets the black-hole mass can be prescribed a priori, without recourse to the iterative procedure that is necessary for wormhole data.« less

  8. Healing assessment of tile sets for error tolerance in DNA self-assembly.

    PubMed

    Hashempour, M; Mashreghian Arani, Z; Lombardi, F

    2008-12-01

    An assessment of the effectiveness of healing for error tolerance in DNA self-assembly tile sets for algorithmic/nano-manufacturing applications is presented. Initially, the conditions for correct binding of a tile to an existing aggregate are analysed using a Markovian approach; based on this analysis, it is proved that correct aggregation (as identified with a so-called ideal tile set) is not always met for the existing tile sets for nano-manufacturing. A metric for assessing tile sets for healing by utilising punctures is proposed. Tile sets are investigated and assessed with respect to features such as error (mismatched tile) movement, punctured area and bond types. Subsequently, it is shown that the proposed metric can comprehensively assess the healing effectiveness of a puncture type for a tile set and its capability to attain error tolerance for the desired pattern. Extensive simulation results are provided.

  9. A Kinect(™) camera based navigation system for percutaneous abdominal puncture.

    PubMed

    Xiao, Deqiang; Luo, Huoling; Jia, Fucang; Zhang, Yanfang; Li, Yong; Guo, Xuejun; Cai, Wei; Fang, Chihua; Fan, Yingfang; Zheng, Huimin; Hu, Qingmao

    2016-08-07

    Percutaneous abdominal puncture is a popular interventional method for the management of abdominal tumors. Image-guided puncture can help interventional radiologists improve targeting accuracy. The second generation of Kinect(™) was released recently, we developed an optical navigation system to investigate its feasibility for guiding percutaneous abdominal puncture, and compare its performance on needle insertion guidance with that of the first-generation Kinect(™). For physical-to-image registration in this system, two surfaces extracted from preoperative CT and intraoperative Kinect(™) depth images were matched using an iterative closest point (ICP) algorithm. A 2D shape image-based correspondence searching algorithm was proposed for generating a close initial position before ICP matching. Evaluation experiments were conducted on an abdominal phantom and six beagles in vivo. For phantom study, a two-factor experiment was designed to evaluate the effect of the operator's skill and trajectory on target positioning error (TPE). A total of 36 needle punctures were tested on a Kinect(™) for Windows version 2 (Kinect(™) V2). The target registration error (TRE), user error, and TPE are 4.26  ±  1.94 mm, 2.92  ±  1.67 mm, and 5.23  ±  2.29 mm, respectively. No statistically significant differences in TPE regarding operator's skill and trajectory are observed. Additionally, a Kinect(™) for Windows version 1 (Kinect(™) V1) was tested with 12 insertions, and the TRE evaluated with the Kinect(™) V1 is statistically significantly larger than that with the Kinect(™) V2. For the animal experiment, fifteen artificial liver tumors were inserted guided by the navigation system. The TPE was evaluated as 6.40  ±  2.72 mm, and its lateral and longitudinal component were 4.30  ±  2.51 mm and 3.80  ±  3.11 mm, respectively. This study demonstrates that the navigation accuracy of the proposed system is acceptable, and that the second generation Kinect(™)-based navigation is superior to the first-generation Kinect(™), and has potential of clinical application in percutaneous abdominal puncture.

  10. An imaging anatomical study on percutaneous kyphoplasty for lumbar via a unilateral transverse process-pedicle approach.

    PubMed

    Wang, Song; Wang, Qing; Kang, Jianping; Xiu, Peng; Wang, Gaoju

    2014-04-20

    An imaging anatomical measurement. To investigate the anatomical feasibility of percutaneous kyphoplasty for lumbar osteoporotic vertebral compression fractures via a unilateral transverse process-pedicle approach (TPA). Kyphoplasty via a unilateral approach has been reported and good clinical results have been achieved. However, because of the lack of an anatomical study, these approaches have yet to be popularized. A total of 150 lumbar vertebral bodies of 30 patients were simulated kyphoplasty on the computed tomographic scans through conventional transpedicle approach (CTA) and the TPA, respectively. Anatomical parameters including the distance between the entry point and the midline of the vertebral body, the puncture inclination angle, and the success rate of puncture were measured and compared. The distance between the entry point and the midline from L1 to L5 lumbar levels varied from 20.6 ± 2.2 mm to 28.6 ± 2.9 mm in the CTA group and from 23.6 ± 2.2 mm to 33.6 ± 2.9 mm in the TPA group. The entry point from L1 to L5 in the TPA group was 3.0 ± 2.1 mm to 5.1 ± 2.7 mm more lateral than that in the CTA group. The medial inclination angles from L1 to L5 were 30.2° ± 6.4° to 47.7° ± 5.4° in the TPA and 15.3° ± 6.0° to 22.8° ± 8.7° in the CTA group. The inclination angles in the TPA group were greater than that in the CTA group and the safe range of the puncture angles was also wider. The success rate was 51.7% in the CTA group and 87.7% in the TPA group. The entry point through a TPA was localized at the midline of the transverse process, 3.0 to 5.1 mm outside the lateral margin of the pedicle projection. Compared with CTA, the puncture inclination angle in the TPA approach was much larger with a wider safe puncture range. The TPA approach allowed an easy puncture to meet or surpass the midline of the lumbar vertebral body. N/A.

  11. [Puncture scrotostomy--a treatment method in acute inflammatory diseases of the scrotal organs].

    PubMed

    Shapoval, V I; Asimov, D A; Lesovoĭ, V N

    1989-01-01

    A method for the treatment of acute inflammatory diseases of the scrotal organs by means of puncture scrotostomy, which consists in passing the indwelling micro-irrigator into a cavity of the serous sheath of the testis and epididymis and administration via this route of antibacterial and resolving preparations for 4-5 days, is suggested. A method approved in treatment of 45 patients permits to avoid surgical intervention, and is highly effective.

  12. Software Communications Architecture (SCA) Compliant Software Defined Radio Design for IEEE 802.16 Wirelessman-OFDMTM Transceiver

    DTIC Science & Technology

    2006-12-01

    Convolutional encoder of rate 1/2 (From [10]). Table 3 shows the puncturing patterns used to derive the different code rates . X precedes Y in the order... convolutional code with puncturing configuration (From [10])......11 Table 4. Mandatory channel coding per modulation (From [10...a concatenation of a Reed– Solomon outer code and a rate -adjustable convolutional inner code . At the transmitter, data shall first be encoded with

  13. Presumed Group B Streptococcal Meningitis After Epidural Blood Patch.

    PubMed

    Beilin, Yaakov; Spitzer, Yelena

    2015-06-15

    Bacterial meningitis after epidural catheter placement is rare. We describe a case in which a parturient received labor epidural analgesia for vaginal delivery complicated by dural puncture. The patient developed postdural puncture headache and underwent 2 separate epidural blood patch procedures. She subsequently developed a headache with fever and focal neurologic deficits. She was treated with broad spectrum antibiotics for presumed meningitis, and she made a full recovery. Blood cultures subsequently grew group B streptococcus.

  14. [Management of suspected meningitis in the emergency department].

    PubMed

    Degraeve, Anaïs; Clemente, Marc; Huttner, Benedikt; Rutschmann, Olivier

    2016-08-10

    Febrile meningeal syndrome is a medical emergency. Lumbar puncture keeps its gold-standard status as clinical findings are neither sensitive nor specific enough. Antibiotics and steroids are ideally administered within the first 30 minutes after admission when bacterial meningitis is suspected. A cerebral CT-scan before lumbar puncture is mandatory for selected patients only. PCR for viruses in the cerebrospinal fluid can inform diagnosis and treatment. Meningitis caused by enterovirus can usually be managed at home.

  15. [Ropivacaine use in transnasal sphenopalatine ganglion block for post dural puncture headache in obstetric patients - case series].

    PubMed

    Furtado, Inês; Lima, Isabel Flor de; Pedro, Sérgio

    2018-02-02

    Sphenopalatine ganglion block is widely accepted in chronic pain; however it has been underestimated in post dural puncture headache treatment. The ganglion block does not restore normal cerebrospinal fluid dynamics but effectively reduces symptoms associated with resultant hypotension. When correctly applied it may avoid performance of epidural blood patch. The transnasal approach is a simple and minimally invasive technique. In the cases presented, we attempted to perform and report the ganglion block effectiveness and duration, using ropivacaine. We present four obstetrics patients with post dural puncture headache, after epidural or combined techniques, with Tuohy needle 18G that underwent a safe and successful Sphenopalatine ganglion block. We performed the block 24-48h after dural puncture, with 4mL of ropivacaine 0.75% in each nostril. In three cases pain recurred within 12-48h, although less intense. In one patient a second block was performed with complete relief and without further recurrence. In the other two patients a blood patch was performed without success. All patients were asymptomatic within 7 days. The average duration of analgesic effect of the block remains poorly defined. In the cases reported, blocking with ropivacaine was a simple, safe and effective technique, with immediate and sustained pain relief for at least 12-24h. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  16. No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle.

    PubMed

    Kim, Sung R; Chae, Hyun S; Yoon, Mi J; Han, Jung H; Cho, Kwang J; Chung, Sun J

    2012-01-30

    Supine recumbence has been widely performed to prevent post-lumbar puncture headache (PLPH). However, the optimal duration of supine recumbence is controversial. The aim of the study is to compare the occurrence of PLPH according to the duration of supine recumbence in patients with neurological disorders. A non-equivalent control/experimental pre-/post-test study design was used. Seventy consecutive patients were prospectively enrolled between July 2007 and July 2008. Thirty-five patients underwent supine recumbence for four hours after lumbar puncture (Group 1) and 35 patients underwent supine recumbence for one hour (Group 2). The overall frequency of PLPH was 31.4%. The frequency of PLPH was not significantly different between the Group 1 (28.6%) and Group 2 (34.3%) (P = 0.607). In patients with PLPH, the median severity (P = 0.203) and median onset time of PLPH (P = 0.582) were not significantly different between the two groups. In a logistic regression analysis, the previous history of post-lumbar puncture headache was a significant risk factor for the occurrence of PLPH (OR = 11.250, 95% CI: 1.10-114.369, P = 0.041). Our study suggests that short duration (one hour) of supine recumbence may be as efficient as long duration (four hours) of supine recumbence to prevent PLPH.

  17. Engineering Polymer Blends for Impact Damage Mitigation

    NASA Technical Reports Server (NTRS)

    Gordon, Keith L.; Smith, Russell W.; Working, Dennis C.; Siochi, Emilie J.

    2016-01-01

    Structures containing polymers such as DuPont's Surlyn® 8940, demonstrate puncture healing when impacted by a 9 millimeter projectile traveling from speeds near 300 meters per second (1,100 feet per second) to hypervelocity impacts in the micrometeoroid velocity range of 5 kilometers per second (16,000 feet per second). Surlyn® 8940 puncture heals over a temperature range of minus 30 degrees Centigrade to plus 70 degrees Centigrade and shows potential for use in pressurized vessels subject to impact damage. However, such polymers are difficult to process and limited in applicability due to their low thermal stability, poor chemical resistance and overall poor mechanical properties. In this work, several puncture healing engineered melt formulations were developed. Moldings of melt blend formulations were impacted with a 5.56 millimeter projectile with a nominal velocity of 945 meters per second (3,100 feet per second) at about 25 degrees Centigrade, 50 degrees Centigrade and 100 degrees Centigrade, depending upon the specific blend being investigated. Self-healing tendencies were determined using surface vacuum pressure tests and tensile tests after penetration using tensile dog-bone specimens (ASTM D 638-10). For the characterization of tensile properties both pristine and impacted specimens were tested to obtain tensile modulus, yield stress and tensile strength, where possible. Experimental results demonstrate a range of new puncture healing blends which mitigate damage in the ballistic velocity regime.

  18. Experimental and Modeling Studies of Crush, Puncture, and Perforation Scenarios in the Steven Impact Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vandersall, K S; Chidester, S K; Forbes, J W

    2002-06-28

    The Steven test and associated modeling has greatly increased the fundamental knowledge of practical predictions of impact safety hazards for confined and unconfined explosive charges. Building on a database of initial work, experimental and modeling studies of crush, puncture, and perforation scenarios were investigated using the Steven impact test. The descriptions of crush, puncture, and perforation arose from safety scenarios represented by projectile designs that ''crush'' the energetic material or either ''puncture'' with a pinpoint nose or ''perforate'' the front cover with a transportation hook. As desired, these scenarios offer different aspects of the known mechanisms that control ignition: friction,more » shear and strain. Studies of aged and previously damaged HMX-based high explosives included the use of embedded carbon foil and carbon resistor gauges, high-speed cameras, and blast wave gauges to determine the pressure histories, time required for an explosive reaction, and the relative violence of those reactions, respectively. Various ignition processes were modeled as the initial reaction rate expression in the Ignition and Growth reaction rate equations. Good agreement with measured threshold velocities, pressure histories, and times to reaction was calculated for LX-04 impacted by several projectile geometries using a compression dependent ignition term and an elastic-plastic model with a reasonable yield strength for impact strain rates.« less

  19. Shrunk loop theorem for the topology probabilities of closed Brownian (or Feynman) paths on the twice punctured plane

    NASA Astrophysics Data System (ADS)

    Giraud, O.; Thain, A.; Hannay, J. H.

    2004-02-01

    The shrunk loop theorem proved here is an integral identity which facilitates the calculation of the relative probability (or probability amplitude) of any given topology that a free, closed Brownian (or Feynman) path of a given 'duration' might have on the twice punctured plane (plane with two marked points). The result is expressed as a 'scattering' series of integrals of increasing dimensionality based on the maximally shrunk version of the path. Physically, this applies in different contexts: (i) the topology probability of a closed ideal polymer chain on a plane with two impassable points, (ii) the trace of the Schrödinger Green function, and thence spectral information, in the presence of two Aharonov-Bohm fluxes and (iii) the same with two branch points of a Riemann surface instead of fluxes. Our theorem starts from the Stovicek scattering expansion for the Green function in the presence of two Aharonov-Bohm flux lines, which itself is based on the famous Sommerfeld one puncture point solution of 1896 (the one puncture case has much easier topology, just one winding number). Stovicek's expansion itself can supply the results at the expense of choosing a base point on the loop and then integrating it away. The shrunk loop theorem eliminates this extra two-dimensional integration, distilling the topology from the geometry.

  20. Mechanics of anesthetic needle penetration into human sciatic nerve.

    PubMed

    Pichamuthu, Joseph E; Maiti, Spandan; Gan, Maria G; Verdecchia, Nicole M; Orebaugh, Steven L; Vorp, David A

    2018-06-06

    Nerve blocks are frequently performed by anesthesiologists to control pain. For sciatic nerve blocks, the optimal placement of the needle tip between its paraneural sheath and epineurial covering is challenging, even under ultrasound guidance, and frequently results in nerve puncture. We performed needle penetration tests on cadaveric isolated paraneural sheath (IPS), isolated nerve (IN), and the nerve with overlying paraneural sheath (NPS), and quantified puncture force requirement and fracture toughness of these specimens to assess their role in determining the clinical risk of nerve puncture. We found that puncture force (123 ± 17 mN) and fracture toughness (45.48 ± 9.72 J m -2 ) of IPS was significantly lower than those for NPS (1440 ± 161 mN and 1317.46 ± 212.45 Jm -2 , respectively), suggesting that it is not possible to push the tip of the block needle through the paraneural sheath only, without pushing it into the nerve directly, when the sheath is lying directly over the nerve. Results of this study provide a physical basis for tangential placement of the needle as the ideal situation for local anesthetic deposition, as it allows for the penetration of the sheath along the edge of the nerve without entering the epineurium. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. No effect of recumbency duration on the occurrence of post-lumbar puncture headache with a 22G cutting needle

    PubMed Central

    2012-01-01

    Background Supine recumbence has been widely performed to prevent post-lumbar puncture headache (PLPH). However, the optimal duration of supine recumbence is controversial. The aim of the study is to compare the occurrence of PLPH according to the duration of supine recumbence in patients with neurological disorders. Methods A non-equivalent control/experimental pre-/post-test study design was used. Seventy consecutive patients were prospectively enrolled between July 2007 and July 2008. Thirty-five patients underwent supine recumbence for four hours after lumbar puncture (Group 1) and 35 patients underwent supine recumbence for one hour (Group 2). Results The overall frequency of PLPH was 31.4%. The frequency of PLPH was not significantly different between the Group 1 (28.6%) and Group 2 (34.3%) (P = 0.607). In patients with PLPH, the median severity (P = 0.203) and median onset time of PLPH (P = 0.582) were not significantly different between the two groups. In a logistic regression analysis, the previous history of post-lumbar puncture headache was a significant risk factor for the occurrence of PLPH (OR = 11.250, 95% CI: 1.10-114.369, P = 0.041). Conclusions Our study suggests that short duration (one hour) of supine recumbence may be as efficient as long duration (four hours) of supine recumbence to prevent PLPH. PMID:22289169

  2. Optical coefficient measurements using bulk living tissue by an optical fiber puncture with FOV change

    NASA Astrophysics Data System (ADS)

    Nakazawa, Haruna; Doi, Marika; Ogawa, Emiyu; Arai, Tsunenori

    2018-02-01

    To avoid an instability of the optical coefficient measurement using sliced tissue preparation, we proposed the combination of light intensity measurement through an optical fiber puncturing into a bulk tissue varying field of view (FOV) and ray tracing calculation using Monte-Carlo method. The optical coefficients of myocardium such as absorption coefficient μa, scattering coefficient μs, and anisotropic parameter g are used in the myocardium optical propagation. Since optical coefficients obtained using thin sliced tissue could be instable because they are affected by dehydration and intracellular fluid effusion on the sample surface, variety of coefficients have been reported over individual optical differences of living samples. The proposed method which combined the experiment using the bulk tissue with ray tracing calculation were performed. In this method, a 200 μmΦ high-NA silica fiber installed in a 21G needle was punctured up to the bottom of the myocardial bulk tissue over 3 cm in thickness to measure light intensity changing the fiber-tip depth and FOV. We found that the measured attenuation coefficients decreased as the FOV increased. The ray trace calculation represented the same FOV dependence in above mentioned experimental result. We think our particular fiber punctured measurement using bulk tissue varying FOV with Inverse Monte-Carlo method might be useful to obtain the optical coefficients to avoid sample preparation instabilities.

  3. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  4. Microneedle-based minimally-invasive measurement of puncture resistance and fracture toughness of sclera.

    PubMed

    Park, Seung Hyun; Lee, Kang Ju; Lee, JiYong; Yoon, Jae Hyoung; Jo, Dong Hyun; Kim, Jeong Hun; Kang, Keonwook; Ryu, WonHyoung

    2016-10-15

    The sclera provides the structural support of the eye and protects the intraocular contents. Since it covers a large portion of the eye surface and has relatively high permeability for most drugs, the sclera has been used as a major pathway for drug administration. Recently, microneedle (MN) technology has shown the possibility of highly local and minimally-invasive drug delivery to the eye by MN insertion through the sclera or the suprachoroidal space. Although ocular MN needs to be inserted through the sclera, there has been no systematic study to understand the mechanical properties of the sclera, which are important to design ocular MNs. In this study, we investigated a MN-based method to measure the puncture resistance and fracture toughness of the sclera. To reflect the conditions of MN insertion into the sclera, force-displacement curves obtained from MN-insertion tests were used to estimate the puncture resistance and fracture toughness of sclera tissue. To understand the effect of the insertion conditions, dependency of the mechanical properties on insertion speeds, pre-strain of the sclera, and MN sizes were analyzed and discussed. Measurement of mechanical property of soft biological tissue is challenging due to variations between tissue samples or lack of well-defined measurement techniques. Although non-invasive measurement techniques such as nano/micro indentation were employed to locally measure the elastic modulus of soft biological materials, mechanical properties such as puncture resistance or fracture toughness, which requires "invasive" measurement and is important for the application of "microneedles or hypodermic needles", has not been well studied. In this work, we report minimally-invasive measurement of puncture resistance and fracture toughness of sclera using a double MN insertion method. Parametric studies showed that use of MN proved to be advantageous because of minimally-invasive insertion into tissue as well as higher sensitivity to sub-tissue architecture during the measurement. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Glucosamine Supplementation Demonstrates a Negative Effect On Intervertebral Disc Matrix in an Animal Model of Disc Degeneration

    PubMed Central

    Jacobs, Lloydine; Vo, Nam; Coehlo, J. Paulo; Dong, Qing; Bechara, Bernard; Woods, Barrett; Hempen, Eric; Hartman, Robert; Preuss, Harry; Balk, Judith; Kang, James; Sowa, Gwendolyn

    2013-01-01

    Study Design Laboratory based controlled in vivo study Objective To determine the in vivo effects of oral glucosamine sulfate on intervertebral disc degeneration Summary of Background Data Although glucosamine has demonstrated beneficial effect in articular cartilage, clinical benefit is uncertain. A CDC report from 2009 reported that many patients are using glucosamine supplementation for low back pain (LBP), without significant evidence to support its use. Because disc degeneration is a major contributor of LBP, we explored the effects of glucosamine on disc matrix homeostasis in an animal model of disc degeneration. Methods Eighteen skeletally mature New Zealand White rabbits were divided into four groups: control, annular puncture, glucosamine, and annular puncture+glucosamine. Glucosamine treated rabbits received daily oral supplementation with 107mg/day (weight based equivalent to human 1500mg/day). Annular puncture surgery involved puncturing the annulus fibrosus (AF) of 3 lumbar discs with a 16G needle to induce degeneration. Serial MRIs were obtained at 0, 4, 8, 12, and 20 weeks. Discs were harvested at 20 weeks for determination of glycosaminoglycan(GAG) content, relative gene expression measured by RT-PCR, and histological analyses. Results The MRI index and NP area of injured discs of glucosamine treated animals with annular puncture was found to be lower than that of degenerated discs from rabbits not supplemented with glucosamine. Consistent with this, decreased glycosaminoglycan was demonstrated in glucosamine fed animals, as determined by both histological and GAG content. Gene expression was consistent with a detrimental effect on matrix. Conclusions These data demonstrate that the net effect on matrix in an animal model in vivo, as measured by gene expression, MRI, histology, and total proteoglycan is anti-anabolic. This raises concern over this commonly used supplement, and future research is needed to establish the clinical relevance of these findings. PMID:23324939

  6. Impact of fine needle aspiration (FNA) and of the number of punctures on the feline testis: clinical, gross anatomy and histological assessment.

    PubMed

    Gouletsou, Pagona G; Galatos, Apostolos D; Sideri, Aikaterini I; Kostoulas, Polychronis

    2012-07-01

    The safety of testicular fine needle aspiration (FNA) has been proven in dogs but has not been fully established in men, while studies in rats have given contradictory results. Furthermore, the extent of damage inflicted by multiple punctures is unknown. The aim of this study was to determine the impact of FNA and of the number of punctures on the feline testis with clinical, gross anatomy and histological examinations. Twenty-seven sexually mature healthy laboratory Domestic Shorthair cats were randomly assigned to two groups: 5 cats in which no FNA was performed (control group), and 22 cats which had their left and right testis punctured with a 26 ga needle towards 3 and 8 directions, respectively (experimental group). Two cats at a time were orchiectomized 5 or 30 min, 1, 2, 4, 7 or 14 days or 1, 2, 3 or 4 mo post-aspiration. The cats of the control group were also orchiectomized. During the first week post-aspiration clinical examination revealed vaginal cavity hematoma (8/44 testes), while the histological findings were focal hemorrhagic areas (20/24 testes), erythrocytes inside the seminiferous tubules' lumen (9/24 testes), and germinal cell degeneration in <1.94% of the seminiferous tubules (15/24 testes). After the first week the histological findings were germinal cell degeneration in <2.14% of the seminiferous tubules (19/20 testes) and enlargement of the lumen of <5.16% of the seminiferous tubules (7/20 testes). The germinal epithelium and interstitium had an overall normal appearance. No significant differences were observed between the left and right testis. The results of the study indicate that testicular FNA should be considered a safe procedure in the cat when up to 8 punctures are performed. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uchida, Barry T.; Pavcnik, Dusan, E-mail: pavcnikd@ohsu.edu; Shimohira, Masashi

    Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display themore » septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.« less

  8. Level of conus medullaris termination in adult population analyzed by kinetic magnetic resonance imaging.

    PubMed

    Liu, An; Yang, Kaixiang; Wang, Daling; Li, Changqing; Ren, Zhiwei; Yan, Shigui; Buser, Zorica; Wang, Jeffrey C

    2017-07-01

    To investigate the change of conus medullaris termination (CMT) level in neutral, flexion and extension positions and to analyze the effects of age and gender on the CMT level. The midline sagittal T2-weighted kinetic magnetic resonance imaging (kMRI) study of 585 patients was retrospectively reviewed to identify the level of CMT. All patients were in an upright position. A straight line perpendicular to the long axis of the cord was drawn from the tip of the cord and then subtended to the adjacent vertebra or disk space. The CMT level was labeled in relation to the upper, middle and lower segments of adjacent vertebra or disk space and assigned values from 0 to 12 [0 = upper third of T12 (T12U), and 12 = upper third of L3 (L3U)]. All parameters were collected for neutral, flexion and extension positions. The level of CMT had the highest incidence (17.61%) at L1 lower (L1L) in neutral position, 17.44% at L1 upper (L1U) in flexion, and 16.92% at L1 middle (L1M) in extension with no significant differences among three positions (p > 0.05) in weight-bearing status. Moreover, the level of CMT was not correlated with age (p > 0.05). In terms of gender, the level of CMT was lower in women than in men in neutral position, flexion, and extension (p < 0.05). Furthermore, when divided by age in decades, there was a significant difference between females and males in the age group 60-69 years in neutral, flexion and extension position, respectively (p < 0.05). The level of CMT in the neutral position was in accordance with previous cadaveric and supine-position MRI studies, and it did not change with flexion and extension. Women had lower CMT level than men, especially in the older population. This information can be very valuable when performing spinal anesthesia and spinal punctures.

  9. Acupuncture for the Management of Postdural Puncture Headache: A Case Report

    PubMed Central

    Chang, Alexandra; Acquah, Joseph; Reddy, Sanjay

    2016-01-01

    Postdural puncture headache (PDPH) is a recognized complication of neuraxial anesthesia. This case report documents 1 patient who developed PDPH following epidural anesthesia for postoperative pain control. The patient declined conventional treatments, including an epidural blood patch and intravenous caffeine. This report documents successful use of adjunct acupuncture for the management of PDPH. Additional research on acupuncture as a potential adjunctive therapy for PDPH is needed, particularly for patients who are reluctant to receive more invasive treatments. PMID:26937320

  10. Performance Analysis of IEEE 802.11g Waveform Transmitted Over a Fading Channel with Pulse-Noise Interference

    DTIC Science & Technology

    2006-06-01

    called packet binary convolutional code (PBCC), was included as an option for performance at rate of either 5.5 or 11 Mpbs. The second offshoot...and the code rate is r k n= . A general convolutional encoder can be implemented with k shift-registers and n modulo-2 adders. Higher rates can be...derived from lower rate codes by employing “ puncturing .” Puncturing is a procedure for omitting some of the encoded bits in the transmitter (thus

  11. Diagnostic Lumbar Puncture Among Children With Facial Palsy in a Lyme Disease Endemic Area.

    PubMed

    Paydar-Darian, Niloufar; Kimia, Amir A; Lantos, Paul M; Fine, Andrew M; Gordon, Caroline D; Gordon, Catherine R; Landschaft, Assaf; Nigrovic, Lise E

    2017-06-01

    We identified 620 children with peripheral facial palsy of which 211 (34%) had Lyme disease. The 140 children who had a lumbar puncture performed were more likely to be hospitalized (73% LP performed vs 2% no LP) and to receive parenteral antibiotics (62% LP performed vs 6% no LP). © The Author 2016. Published by Oxford University Press on behalf of The Journal of the Pediatric Infectious Diseases Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. Transjugular Intrahepatic Portosystemic Shunt Creation in Budd-Chiari Syndrome: Percutaneous Ultrasound-Guided Direct Simultaneous Puncture of the Portal Vein and Vena Cava

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali

    Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.

  13. [Precise application of Traditional Chinese Medicine in minimally-invasive techniques].

    PubMed

    Dong, Fu-Hui

    2018-06-25

    The miminally-invasive techniques of traditional Chinese medicine(TCM) uses different types of acupuncture needles to treat diseased locations with special techniques. These techniques include different methods of insertion and closed incision (press cutting, sliding cutting, scrape cutting, etc.). This needling technique is based on the traditional Chinese medicine theories of Pi Bu (cutaneous), Jing Jin (sinew), Jing Luo (meridian), Wu Ti (five body structure components) and Zang Fu (organ system). Commonly used needles include: needle Dao , needle with edge, Pi needle, Shui needle, Ren needle, Gou needle, Chang Yuan needle, Bo needle and so on. The principle of this minimally-invasive technique of TCM is to achieve the greatest healing benefit with the least amount of anatomical and physiological intervention. This will result in the highest standard of health care with the lowest rehabilitative need and burden of care. In the past 20 years, through the collaborative research of several hundred hospitals across China, we systemically reviewed the best minimally invasive technique of TCM and the first line treatments for selective conditions. In 2013, the Department of Medical Affairs of the State Administration of Traditional Chinese Medicine created "Traditional Chinese Medicine Technical Manual"(General Version) and released it nationwide, its contents include: (1)Minimally invasive scar tissue release. ¹Suitable for Bi and pain syndromes of neck, shoulder, waist, buttocks and extremities. ²Degeneration causes local hypertrophy and inflammation, creating local tissue adhesion. ³There are two kind incision methods-press cutting and slide cutting. (2)Minimally invasive fascial tension release. ¹Suitable for localized fascial tension caused by trauma, overuse, or wind-cold-dampness, leading to compensatory hyperplasia. ²Long term high-stress stimulation to local fascia creates compensatory hyperplasia, Ashi points, and tissue texture changes (cords, nodules, masses). ³According to the different structural features of the needles, there are two incision methods: penetrating from the outside to the inside and pulling from inside to outside. (3)Minimally invasive decompression technique. ¹Suitable for internal pressure changes within organ cavities caused by trauma, degeneration, inflammation, such as compartment syndrome, bone marrow edema, increased intraluminal pressure in the bone marrow. ²According to the different tissues, it is categorized into soft tissue decompression, and bone decompression. (4)Minimally invasive orthopedic surgery. Applicable to some postural, developmental deformity correction, mainly through the dynamic balance method and/or static balance method. (5)Minimally invasive dissection. Suitable for fractures, tendons injury caused by deep soft tissue adhesion. (6)Minimally invasive separation. ¹Suitable for cutaneous, sinew regions, superficial adhesions due to lesions, and local post-operative incision adhesions. ²According to the structure of the needle tip, the methods are divided into sharp separation and blunt dissection. (7)Minimally invasive sustained pressure technique. ¹Suitable for neuromuscular dysfunction which causes JING (spasm) syndrome and WEI (atrophy) syndrome. ²The needle is applied with sustained pressure, without penetrating select tissue surface. This includes: nerve root sustained pressure technique; peripheral nerve sustained pressure technique; muscle sustained pressure technique; fascial contact procedure; cutaneous sustained pressure technique.(8)Minimally invasive insertion technique. ¹Suitable for systemic regulation to treat disease. ²Different organs are connected to different layers of tissue. Therefore, to treat specific conditions, specific tissues must be targeted. ³For example, back Shu points are used to treat vertigo from cervical spine issues, and spinal degeneration associated digestion issue. ⁴The internal organs can be regulated by the pathways that runs along the different layers of tissue. The types of stimulation include: meridian acupoint stimulation; cutaneous stimulation; fascia stimulation; mucle stimulation; periosteum stimulation. The clinical application of these techniques has enriched the drug-free therapies of traditional Chinese medicine and achieved excellent outcomes, but at the same time it also raises an important question. How can we apply these minimally invasive techniques to clinical practice so it can be safe and effective? In addition, how can practitioners, individually and further develop their understanding of this minimally invasive technique progressive manner? We make the following recommendations. (1)Clear diagnosis and precise application. Any approach has specific indications and choosing the correct technique comes from a comprehensive understanding of its advantages and disadvantages. Moreover, the accurate application of the technique depends the expertise of the practitioner. Through systematic review and clinical observation, we formulated the First Line Treatment, the Second Line Treatment, and the Third Line Treatment for specific conditions. Using the information gathered from research, practitioners can decide on which point is appropriate to use based on the stage of disease progression. For example, common conditions like the nerve ending tension pain(i.e. cutaneous nerve entrapment syndrome) is caused by stress concentration. There are two types of treatment for this condition: ¹Change in the response to stress state (i.e.non-invasive approach such as manual therapy and physiotherapy). ²Change in state of surrounding environment (i.e. invasive approach such as Pi Needle). Before tissue texture changes to pain point, cord, nodules, the former approach is effective. Once tissue texture changes, the latter approach is First Line Treatment. (2)Systematic training and disease progression training. The minimally invasive techniques of traditional Chinese medicine can treat many kinds of disease. To ensure its safety, organization, progressive development, practitioners are trained systematically and manage their treatment approach through disease hierarchy. Moreover, this technique should be conducted according to its technical difficulty, operating conditions, and expertise of the practitioner. The application of minimally invasive techniques of traditional Chinese medicine does not depend on the hospitals' administration system or the regulatory college of medical professionals. The minimally invasive techniques of TCM should be taught from easy to difficult, simple to complicated, and requires gradual progression by the practitioners. Eventually, the minimally invasive techniques of TCM's diagnostic and treatment protocol can be created. These protocols are currently available for reference: ¹Forming diagnosis and differential diagnosis for the conditions below requires expert diagnostic and application skills: cerebral palsy; cervical vertigo; cervical headache; cervical precordial pain; other spine-related diseases. ²The requirements for the diagnosis and differential diagnosis of such techniques are relatively high, and special training is required for the practitioner who performs this technique. The conditions below uses minimally invasive orthopedic surgery and dissection: scar contracture deformity; congenital developmental malformations; cervical Bi -syndrome; shoulder pain syndrome; knee Bi -syndrome; low back pain; cervical spondylosis; lumbar disc herniation; avascular necrosis of the femoral head; ankylosing spondylitis. ³There are no special requirements for the diagnosis and differential diagnosis of such techniques, and special training is required for the practitioner who performs this technique. The technical content is mainly decompression and scar tissue release. a)Muscle strain diseases: levator scapulae, splenius capitis, splenius cervicis, supraspinatus, infraspinatus, teres minor, teres major, serratus posterior superior, serratus posterior inferior, piriformis, gluteus maximus, gluteus medius, and gluteus minimus, erector spinae. b)Joint degenerative disorders: frozen shoulder, tennis elbow, tenosynovitis, knee osteoarthritis, and plantar fascitis. c) JING-JIN PI-BU pain syndrome (cutaneous nerve entrapment syndrome): occipital great nerve entrapment syndrome, occipital small nerve entrapment syndrome, great auricular nerve entrapment syndrome, suprascapular nerve entrapment syndrome, transverse cutaneous nerve of neck entrapment syndrome. (3)People-centred practice. The most attractive feature of the minimally invasive techniques of TCM is that they do not rely on expensive medical equipment and operating conditions. The key to applying this technique is the practitioners' technique, skill, and expertise. The necessary conditions required to successfully apply this technique is ¹practitioner understands disease progression and diagnosis; ²practitioners' skill in applying technique. We require patient-centered approach, which uses evidence based approach as the focus. We aim to seek the truth from facts, to understand the comprehensive picture, to include pertinent details, to be observant, to be goal oriented, from one to another, from outside to inside, from top to the bottom, compare right from left, through active movement and passive movements and weight-bearing movements, and assisted passive movements to determine instantaneous centre to diagnose stress concentration points. The operating technique is based on the response of patient's tissues to this technique. We must pay attention to diagnosis through palpation: layers, structure, texture, deformity, dislocation, movement characteristic, rhythmic changes. To achieve SHOU MO XIN HUI WU WEI : position, quantify, quantity, timing, and pattern. Accurate grasp of timeliness and dose efficiency. Can distinguish between local or systemic effects of treatment. Through comprehensive judgment of hands feeling, acupuncture needle feeling, and inspiration, to achieve the precious treatment requirements as indicated by the "Huangdi Neijing·Suwen" : "Puncture the bone without damaging tendons, and puncture tendons without damaging muscles, puncture the muscle without damaging pulse, puncture pulse without damaging skin, puncture skin without damaging muscle. Puncture muscle without damage tendons, puncture tendons without damaging bone... Puncture bone without damaging tendons and it means the needle passes through the tendons and arrives at the bone and work on the bone. Puncture tendons without damaging muscles, and it means the needle passes through the muscles and arrives close to the tendon. Puncture the muscle without damaging pulse and it means the needle passes the pulse and does not touch the muscle. Puncture pulse without damaging skin and it means, the needle passes through the skin without penetrating pulse. Puncture skin without damaging muscle and it means, the disease is in the skin and the needles insert into skin but does not damage muscle. Puncture muscle without damage tendons, and it means, the needle passes through the muscle and arrive on the tendon. Puncture tendons without damaging bone." Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  14. Foramen ovale puncture, lesioning accuracy, and avoiding complications: microsurgical anatomy study with clinical implications.

    PubMed

    Peris-Celda, Maria; Graziano, Francesca; Russo, Vittorio; Mericle, Robert A; Ulm, Arthur J

    2013-11-01

    Foramen ovale (FO) puncture allows for trigeminal neuralgia treatment, FO electrode placement, and selected biopsy studies. The goals of this study were to demonstrate the anatomical basis of complications related to FO puncture, and provide anatomical landmarks for improvement of safety, selective lesioning of the trigeminal nerve (TN), and optimal placement of electrodes. Both sides of 50 dry skulls were studied to obtain the distances from the FO to relevant cranial base references. A total of 36 sides from 18 formalin-fixed specimens were dissected for Meckel cave and TN measurements. The best radiographic projection for FO visualization was assessed in 40 skulls, and the optimal trajectory angles, insertion depths, and topographies of the lesions were evaluated in 17 specimens. In addition, the differences in postoperative pain relief after the radiofrequency procedure among different branches of the TN were statistically assessed in 49 patients to determine if there was any TN branch less efficiently targeted. Most severe complications during FO puncture are related to incorrect needle placement intracranially or extracranially. The needle should be inserted 25 mm lateral to the oral commissure, forming an approximately 45° angle with the hard palate in the lateral radiographic view, directed 20° medially in the anteroposterior view. Once the needle reaches the FO, it can be advanced by 20 mm, on average, up to the petrous ridge. If the needle/radiofrequency electrode tip remains more than 18 mm away from the midline, injury to the cavernous carotid artery is minimized. Anatomically there is less potential for complications when the needle/radiofrequency electrode is advanced no more than 2 mm away from the clival line in the lateral view, when the needle pierces the medial part of the FO toward the medial part of the trigeminal impression in the petrous ridge, and no more than 4 mm in the lateral part. The 40°/45° inferior transfacial-20° oblique radiographic projection visualized 96.2% of the FOs in dry skulls, and the remainder were not visualized in any other projection of the radiograph. Patients with V1 involvement experienced postoperative pain more frequently than did patients with V2 or V3 involvement. Anatomical targeting of V1 in specimens was more efficiently achieved by inserting the needle in the medial third of the FO; for V2 targeting, in the middle of the FO; and for V3 targeting, in the lateral third of the FO. Knowledge of the extracranial and intracranial anatomical relationships of the FO is essential to understanding and avoiding complications during FO puncture. These data suggest that better radiographic visualization of the FO can improve lesioning accuracy depending on the part of the FO to be punctured. The angles and safety distances obtained may help the neurosurgeon minimize complications during FO puncture and TN lesioning.

  15. Assessment of Navel Oranges, Clementine Tangerines, and Rutaceous Fruits as Hosts of Bactrocera cucurbitae and Bactrocera latifrons (Diptera: Tephritidae)

    PubMed Central

    McQuate, Grant T.; Follett, Peter A.; Liquido, Nicanor J.; Sylva, Charmaine D.

    2015-01-01

    Export of Citrus spp. fruits may require risk mitigation measures if grown in areas with established tephritid fruit fly (Diptera: Tephritidae) populations capable of infesting the fruits. The host status of Citrus spp. fruits is unclear for two tephritid fruit fly species whose geographic ranges have expanded in recent years: melon fly, Bactrocera cucurbitae (Cocquillett), and Bactrocera latifrons (Hendel). In no choice cage infestation studies, B. latifrons oviposited into intact and punctured Washington navel oranges (Citrus sinensis [L.] Osbeck) and Clementine tangerines (C. reticulata L. var. Clementine), but eggs rarely developed to the adult stage. B. cucurbitae readily infested intact and punctured tangerines, and to a lesser extent punctured oranges, but did not infest intact oranges. Limited cage infestation and only a single literature report of field Citrus spp. infestation suggest that risk mitigation of Citrus spp. for B. latifrons is not needed. Risk mitigation options of Citrus spp. for B. cucurbitae, including heat and cold treatments and systems approaches, are discussed. PMID:26816484

  16. Postdural puncture headache

    PubMed Central

    2017-01-01

    Postdural puncture headache (PDPH) is a common complication after inadvertent dural puncture. Risks factors include female sex, young age, pregnancy, vaginal delivery, low body mass index, and being a non-smoker. Needle size, design, and the technique used also affect the risk. Because PDPH can be incapacitating, prompt diagnosis and treatment are mandatory. A diagnostic hallmark of PDPH is a postural headache that worsens with sitting or standing, and improves with lying down. Conservative therapies such as bed rest, hydration, and caffeine are commonly used as prophylaxis and treatment for this condition; however, no substantial evidence supports routine bed rest and aggressive hydration. An epidural blood patch is the most effective treatment option for patients with unsuccessful conservative management. Various other prophylactic and treatment interventions have been suggested. However, due to a lack of conclusive evidence supporting their use, the potential benefits of such interventions should be weighed carefully against the risks. This article reviews the current literature on the diagnosis, risk factors, pathophysiology, prevention, and treatment of PDPH. PMID:28367283

  17. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  18. Superconformal indices of generalized Argyres-Douglas theories from 2d TQFT

    DOE PAGES

    Song, Jaewon

    2016-02-05

    We present superconformal indices of 4d N = 2 class S theories with certain irregular punctures called type I k,N. This class of theories include generalized Argyres-Douglas theories of type (A k-1, A N-1) and more. We conjecture the superconformal indices in certain simplifi ed limits based on the TQFT structure of the class S theories by writing an expression for the wave function corresponding to the puncture I k,N. We write the Schur limit of the wave function when k and N are coprime. When k = 2, we also conjecture a closed-form expression for the Hall-Littlewood index andmore » the Macdonald index for odd N. From the index, we argue that certain short-multiplet which can appear in the OPE of the stress-energy tensor is absent in the (A 1,A 2n) theory. In addition, we discuss the mixed Schur indices for the N = 1 class S theories with irregular punctures.« less

  19. Venous catheterization with ultrasound navigation

    NASA Astrophysics Data System (ADS)

    Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.

    2015-11-01

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.

  20. Evaluation of two different epidural catheters in clinical practice. narrowing down the incidence of paresthesia!

    PubMed

    Bouman, E A C; Gramke, H F; Wetzel, N; Vanderbroeck, T H T; Bruinsma, R; Theunissen, M; Kerkkamp, H E M; Marcus, M A E

    2007-01-01

    Although epidural anesthesia is considered safe, several complications may occur during puncture and insertion of a catheter. Incidences of paresthesia vary between 0.2 and 56%. A prospective, open, cohort-controlled pilot study was conducted in 188 patients, ASA I-III, age 19-87 years, scheduled for elective surgery and epidural anesthesia. We evaluated a 20 G polyamide (standard) catheter and a 20 G combined polyurethane-polyamide (new) catheter. Spontaneous reactions upon catheter-insertion, paresthesia on questioning, inadvertent dural or intravascular puncture, and reasons for early catheter removal were recorded. The incidence of paresthesia reported spontaneously was 21.3% with the standard catheter and 16.7% with the new catheter. Systematically asking for paresthesia almost doubled the paraesthesia rate. Intravascular cannulation occurred in 5%. No accidental dural punctures occurred. An overall incidence of 13.3% of technical problems led to early catheter removal. The new catheter was at least equivalent to the standard regarding epidural success rate and safety : rate of paresthesia, intravascular and dural cannulation.

  1. Modeling and analysis of film composition on mechanical properties of maize starch based edible films.

    PubMed

    Prakash Maran, J; Sivakumar, V; Thirugnanasambandham, K; Kandasamy, S

    2013-11-01

    The present study investigates the influence of composition (content of maize starch (1-3 g), sorbitol (0.5-1.0 ml), agar (0.5-1.0 g) and tween-80 (0.1-0.5 ml)) on the mechanical properties (tensile strength, elongation, Young's modulus, puncture force and puncture deformation) of the maize starch based edible films using four factors with three level Box-Behnken design. The edible films were obtained by casting method. The results showed that, tween-80 increases the permeation of sorbitol in to the polymer matrix. Increasing concentration of sorbitol (hydrophilic nature and plasticizing effect of sorbitol) decreases the tensile strength, Young's modulus and puncture force of the films. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were obtained for all responses with high R(2) values (R(2)>0.95). 3D response surface plots were constructed to study the relationship between process variables and the responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Vaccine vial stopper performance for fractional dose delivery of vaccines.

    PubMed

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-07-03

    Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced-or fractional-doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery.

  3. Venous catheterization with ultrasound navigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru

    By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less

  4. [Assertiveness and peripheral intravenous catheters dwell time with ultrasonography-guided insertion in children and adolescents].

    PubMed

    Avelar, Ariane Ferreira Machado; Peterlini, Maria Angélica Sorgini; da Pedreira, Mavilde Luz Gonçalves

    2013-06-01

    Randomized controlled trial which aimed to verify whether the use of vascular ultrasound (VUS) increases assertiveness in the use of peripheral venous catheter in children, and the catheter dwell time, when compared to traditional puncture. Data were collected after approval of theethical merit. Children and adolescents undergoing VUS-guided peripheral intravenous (GVUS) or puncture guided by clinical assessment of the venous conditions(CG) were included in the study. Significance level was set at p< or =0.05. The sample was composed of 382 punctures, 188 (49.2%) in VUS Gand 194 (50.8%) in CG, performed in 335 children. Assertiveness was found in 73 (71.6%) GVUS catheters and in 84(71.8%) of the CG (p=0.970), and catheter dwell time presented a median of less than one day in both groups (p=0.121), showing nostatistically significant difference. VUS did not significantly influence the results of the dependent variables investigated. ClinicalTrials.govNCT00930254.

  5. Superconformal indices of generalized Argyres-Douglas theories from 2d TQFT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Jaewon

    We present superconformal indices of 4d N = 2 class S theories with certain irregular punctures called type I k,N. This class of theories include generalized Argyres-Douglas theories of type (A k-1, A N-1) and more. We conjecture the superconformal indices in certain simplifi ed limits based on the TQFT structure of the class S theories by writing an expression for the wave function corresponding to the puncture I k,N. We write the Schur limit of the wave function when k and N are coprime. When k = 2, we also conjecture a closed-form expression for the Hall-Littlewood index andmore » the Macdonald index for odd N. From the index, we argue that certain short-multiplet which can appear in the OPE of the stress-energy tensor is absent in the (A 1,A 2n) theory. In addition, we discuss the mixed Schur indices for the N = 1 class S theories with irregular punctures.« less

  6. Fluoroscopy guided percutaneous renal access in prone position

    PubMed Central

    Sharma, Gyanendra R; Maheshwari, Pankaj N; Sharma, Anshu G; Maheshwari, Reeta P; Heda, Ritwik S; Maheshwari, Sakshi P

    2015-01-01

    Percutaneous nephrolithotomy is a very commonly done procedure for management of renal calculus disease. Establishing a good access is the first and probably the most crucial step of this procedure. A proper access is the gateway to success. However, this crucial step has the steepest learning curve for, in a fluoroscopy guided access, it involves visualizing a three dimensional anatomy on a two dimensional fluoroscopy screen. This review describes the anatomical basis of the renal access. It provides a literature review of all aspects of percutaneous renal access along with the advances that have taken place in this field over the years. The article describes a technique to determine the site of skin puncture, the angle and depth of puncture using a simple mathematical principle. It also reviews the common problems faced during the process of puncture and dilatation and describes the ways to overcome them. The aim of this article is to provide the reader a step by step guide for percutaneous renal access. PMID:25789297

  7. Popliteal versus tibial retrograde access for subintimal arterial flossing with antegrade-retrograde intervention (SAFARI) technique.

    PubMed

    Hua, W R; Yi, M Q; Min, T L; Feng, S N; Xuan, L Z; Xing, J

    2013-08-01

    This study aimed to ascertain differences in benefit and effectiveness of popliteal versus tibial retrograde access in subintimal arterial flossing with the antegrade-retrograde intervention (SAFARI) technique. This was a retrospective study of SAFARI-assisted stenting for long chronic total occlusion (CTO) of TASC C and D superficial femoral lesions. 38 cases had superficial femoral artery lesions (23 TASC C and 15 TASC D). All 38 cases underwent SAFARI-assisted stenting. The ipsilateral popliteal artery was retrogradely punctured in 17 patients. A distal posterior tibial (PT) or dorsalis pedis (DP) artery was retrogradely punctured in 21 patients, and 16 of them were punctured after open surgical exposure. SAFARI technical success was achieved in all cases. There was no significant difference in 1-year primary patency (75% vs. 78.9%, p = .86), secondary patency (81.2% vs. 84.2%, p = .91) and access complications (p = 1.00) between popliteal and tibial retrograde access. There was statistical difference in operation time between popliteal (140.1 ± 28.4 min) and tibial retrograde access with PT/DP punctures after surgical vessel exposure (120.4 ± 23.0 min, p = .04). The SAFARI technique is a safe and feasible option for patients with infrainguinal CTO (TASC II C and D). The PT or DP as the retrograde access after surgical vessel exposure is a good choice when using the SAFARI technique. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  8. Veress needle insertion into the left hypochondrium for creation of pneumoperitoneum: diagnostic value of tests to determine the position of the needle in unselected patients.

    PubMed

    Becker, Otávio Monteiro; Azevedo, João Luiz Moreira Coutinho; de Azevedo, Otávio Cansanção; Hypólito, Octávio Henrique Mendes; Miyahira, Susana Abe; Miguel, Gustavo Peixoto Soares; Machado, Afonso Cesar Cabral Guedes

    2011-01-01

    To assess the effectiveness of the Veress needle puncture in the left hypochondrium and the accuracy of the tests described for the intraperitoneal correct positioning of the tip of the Veress needle in an unselected population. Ninetyone patients consecutively scheduled for Videolaparoscopy had the abdominal wall punctured in the left hypochondrium. There were no exclusion criteria. The patients received general anesthesia and mechanical ventilation according to the protocol. After puncturing five tests were used to confirm the positioning of the needle tip within the peritoneal cavity: aspiration test--AT; resistance to infusion--Pres; recovery of the infused fluid--Prec, dripping test--DT, and test of initial intraperitoneal pressure--IIPP. The test results were compared with results from literature for groups with defined exclusion criteria. The results were used for calculating sensitivity (S) specificity (E), positive predictive value (PPV) and negative predictive value (NPV). Inferential statistical methods were used to analyze the findings. There were 13 failures. AT had E = 100% and NPV 100%. Pres had S = 100%, E = 0; PPV = 85.71%; NPV does not apply. Prec: S = 100%, E = 53.84%, PPV = 92.85%, NPV = 100%. DT: S = 100%, E = 61.53%, PPV = 93.97% NPV 100%. In IIPP, S, E, PPV and NPV were 100%. The puncture in the left hypochondrium is effective and the performed tests guide the surgeon regardless of sex, BMI, or previous laparotomy.

  9. ‘Neanderthal bone flutes’: simply products of Ice Age spotted hyena scavenging activities on cave bear cubs in European cave bear dens

    PubMed Central

    Diedrich, Cajus G.

    2015-01-01

    Punctured extinct cave bear femora were misidentified in southeastern Europe (Hungary/Slovenia) as ‘Palaeolithic bone flutes’ and the ‘oldest Neanderthal instruments’. These are not instruments, nor human made, but products of the most important cave bear scavengers of Europe, hyenas. Late Middle to Late Pleistocene (Mousterian to Gravettian) Ice Age spotted hyenas of Europe occupied mainly cave entrances as dens (communal/cub raising den types), but went deeper for scavenging into cave bear dens, or used in a few cases branches/diagonal shafts (i.e. prey storage den type). In most of those dens, about 20% of adult to 80% of bear cub remains have large carnivore damage. Hyenas left bones in repeating similar tooth mark and crush damage stages, demonstrating a butchering/bone cracking strategy. The femora of subadult cave bears are intermediate in damage patterns, compared to the adult ones, which were fully crushed to pieces. Hyenas produced round–oval puncture marks in cub femora only by the bone-crushing premolar teeth of both upper and lower jaw. The punctures/tooth impact marks are often present on both sides of the shaft of cave bear cub femora and are simply a result of non-breakage of the slightly calcified shaft compacta. All stages of femur puncturing to crushing are demonstrated herein, especially on a large cave bear population from a German cave bear den. PMID:26064624

  10. The Use of ExoSeal Vascular Closure Device for Direct Antegrade Superficial Femoral Artery Puncture Site Hemostasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Khaitovich, Boris, E-mail: borislena@012.net.il; Yakubovich, Dmitry, E-mail: Dmitry.Yakubovitch@sheba.health.gov.il

    2015-06-15

    PurposeThis study was designed to assess the efficacy and safety of the ExoSeal vascular closure device (VCD) to achieve hemostasis in antegrade access of the superficial femoral artery (SFA).MethodsWe retrospectively reviewed the outcome of ExoSeal VCD used for hemostasis in 110 accesses to the SFA in 93 patients between July 2011 and July 2013. All patients had patent proximal SFA based on computer tomography angiography or ultrasound duplex. Arterial calcifications at puncture site were graded using fluoroscopy. The SFA was accessed in an antegrade fashion with ultrasound or fluoroscopic guidance. In all patients, 5–7F vascular sheaths were used. The ExoSealmore » VCD was applied to achieve hemostasis at the end of the procedure. All patients were clinically examined and had ultrasound duplex exam for any puncture site complications during the 24 h postprocedure.ResultsIn all procedures, the ExoSeal was applied successfully. We did not encounter any device-related technical failure. There were four major complications in four patients (3.6 %): three pseudoaneurysms, which were treated with direct thrombin injection, and one hematoma, which necessitated transfusion of two blood units. All patients with complications were treated with anticoagulation preprocedure or received thrombolytic therapy.ConclusionsThe ExoSeal VCD can be safely used for antegrade puncture of the SFA, with a high procedural success rate (100 %) and a low rate of access site complications (3.6 %)« less

  11. Effects of photoperiod on boll weevil (Coleoptera: Curculionidae) development, survival, and reproduction.

    PubMed

    Greenberg, S M; Sappington, T W; Adamczyk, J J; Liu, T-X; Setamou, M

    2008-12-01

    Effects of photoperiod on development, survival, feeding, and oviposition of boll weevils, Anthonomus grandis grandis Boheman, were assessed under five different photophases (24, 14, 12, 10, and 0 h) at a constant 27 degrees C temperature and 65% RH in the laboratory. Analyses of our results detected positive relationships between photoperiod and puncturing (mean numbers of oviposition and feeding punctures per day), and oviposition (oviposition punctures/oviposition+feeding punctures) activities, and the proportion of squares attacked by boll weevil females. When boll weevil females developed in light:darkness cycles, they produced a significantly higher percentage of eggs developing to adulthood than those developed in 24-h light or dark conditions. In long photoperiod (24:0 and 14:10 h), the number of female progeny was significantly higher and their development time was significantly shorter than those developed in short photoperiod (0:24 and 10:14 h). Lifetime oviposition was significantly highest at 12- and 14-h photophase, lowest at 0- and 10-h photophase, and intermediate at 24 h of light. Life table calculations indicated that boll weevil populations developed in a photoperiod of 14:10 and 12:12 (L:D) h will increase an average of two-fold each generation (Ro) compared with boll weevils developed in 24:0- and 10:14-h photoperiods and 15-fold compared with those at 0:24 h. Knowledge of the photoperiod-dependent population growth potential is critical for understanding population dynamics to better develop sampling protocols and timing insecticide applications.

  12. 1.0 T open-configuration magnetic resonance-guided microwave ablation of pig livers in real time

    PubMed Central

    Dong, Jun; Zhang, Liang; Li, Wang; Mao, Siyue; Wang, Yiqi; Wang, Deling; Shen, Lujun; Dong, Annan; Wu, Peihong

    2015-01-01

    The current fastest frame rate of each single image slice in MR-guided ablation is 1.3 seconds, which means delayed imaging for human at an average reaction time: 0.33 seconds. The delayed imaging greatly limits the accuracy of puncture and ablation, and results in puncture injury or incomplete ablation. To overcome delayed imaging and obtain real-time imaging, the study was performed using a 1.0-T whole-body open configuration MR scanner in the livers of 10 Wuzhishan pigs. A respiratory-triggered liver matrix array was explored to guide and monitor microwave ablation in real-time. We successfully performed the entire ablation procedure under MR real-time guidance at 0.202 s, the fastest frame rate for each single image slice. The puncture time ranged from 23 min to 3 min. For the pigs, the mean puncture time was shorted to 4.75 minutes and the mean ablation time was 11.25 minutes at power 70 W. The mean length and widths were 4.62 ± 0.24 cm and 2.64 ± 0.13 cm, respectively. No complications or ablation related deaths during or after ablation were observed. In the current study, MR is able to guide microwave ablation like ultrasound in real-time guidance showing great potential for the treatment of liver tumors. PMID:26315365

  13. A-scan ultrasound system for real-time puncture safety assessment during percutaneous nephrolithotomy

    NASA Astrophysics Data System (ADS)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.

    2015-03-01

    Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

  14. A comparative study of bio-inspired protective scales using 3D printing and mechanical testing.

    PubMed

    Martini, Roberto; Balit, Yanis; Barthelat, Francois

    2017-06-01

    Flexible natural armors from fish, alligators or armadillo are attracting an increasing amount of attention for their unique combinations of hardness, flexibility and light weight. The extreme contrast of stiffness between hard scales and surrounding soft tissues gives rise to unusual and attractive mechanisms, which now serve as models for the design of bio-inspired armors. Despite this growing interest, there is little guideline for the choice of materials, optimum thickness, size, shape and arrangement for the protective scales. In this work, we explore how the geometry and arrangement of hard scales can be tailored to promote scale-scale interactions. We use 3D printing to fabricate arrays of scales with increasingly complex geometries and arrangements, from simple squares with no overlap to complex ganoid-scales with overlaps and interlocking features. We performed puncture tests and flexural tests on each of the 3D printed materials, and we report the puncture resistance - compliance characteristics of each design on an Ashby chart. The interactions between the scales can significantly increase the resistance to puncture, and these interactions can be maximized by tuning the geometry and arrangement of the scales. Interestingly, the designs that offer the best combinations of puncture resistance and flexural compliance are similar to the geometry and arrangement of natural teleost and ganoid scales, which suggests that natural evolution has shaped these systems to maximize flexible protection. This study yields new insights into the mechanisms of natural dermal armor, and also suggests new designs for personal protective systems. Flexible natural armors from fishes, alligators or armadillos are attracting an increasing amount of attention for their unique and attractive combinations of hardness, flexibility and low weight. Despite a growing interest in bio-inspired flexible protection, there is still little guideline for the choice of materials, optimum thickness, size, shape and arrangement of the protective scales. In this work, we explore how the geometry and arrangement of hard scales affect puncture resistance and flexural compliance, using 3D printing and mechanical testing. Our main finding is that the performance of the scaled skin in terms of puncture resistance can be significantly improved by slight changes in their geometry and arrangement. Our results also suggest that natural evolution has shaped scaled skins to maximize flexible protection. This study yields new insights into the mechanics of natural dermal armors, and also suggests new designs for personal protective systems. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. In Vitro Activities of ABT-492, a New Fluoroquinolone, against 155 Aerobic and 171 Anaerobic Pathogens Isolated from Antral Sinus Puncture Specimens from Patients with Sinusitis

    PubMed Central

    Goldstein, Ellie J. C.; Citron, Diane M.; Merriam, C. Vreni; Warren, Yumi A.; Tyrrell, Kerin L.; Fernandez, Helen T.

    2003-01-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species. PMID:12937015

  16. In vitro activities of ABT-492, a new fluoroquinolone, against 155 aerobic and 171 anaerobic pathogens isolated from antral sinus puncture specimens from patients with sinusitis.

    PubMed

    Goldstein, Ellie J C; Citron, Diane M; Merriam, C Vreni; Warren, Yumi A; Tyrrell, Kerin L; Fernandez, Helen T

    2003-09-01

    ABT-492 exhibited excellent in vitro activities against all 326 aerobic and anaerobic antral puncture sinus isolates tested with MICs (in micrograms per milliliter) at which 90% of the isolates tested were inhibited as follows: Haemophilus influenzae, 0.001; Moraxella catarrhalis, 0.008; and Streptococcus pneumoniae, 0.015. It was four- to sixfold more active than other fluoroquinolones, including against levofloxacin-resistant strains of S. pneumoniae, methicillin-resistant Staphylococcus aureus, and Prevotella species.

  17. Non-polynomial closed string field theory: loops and conformal maps

    NASA Astrophysics Data System (ADS)

    Hua, Long; Kaku, Michio

    1990-11-01

    Recently, we proposed the complete classical action for the non-polynomial closed string field theory, which succesfully reproduced all closed string tree amplitudes. (The action was simultaneously proposed by the Kyoto group). In this paper, we analyze the structure of the theory. We (a) compute the explicit conformal map for all g-loop, p-puncture diagrams, (b) compute all one-loop, two-puncture maps in terms of hyper-elliptic functions, and (c) analyze their modular structure. We analyze, but do not resolve, the question of modular invariance.

  18. Can Diastat Grafts Meet the Challenges of Daily Punctures?

    PubMed

    Chandran, Prem K G; Messer, Diane; Sidwell, Richard A; Stubbs, David H; Nish, Andrew D

    1997-01-01

    To determine whether Diastat grafts can meet the challenges of daily needle punctures required for home hemodialysis (HD), a retrospective analysis was performed on the experience with 47 grafts placed in 44 patients receiving HD three times a week. The control group consisted of 17 patients who received 17 stretch polytetrafluoroethylene (s-PTFE) grafts. Apart from their ability to better contain bleeding after needle withdrawal, in all measures of longevity the Diastat grafts were outperformed by the s-PTFE grafts. No more direct data exist to address the original challenge.

  19. The effect of direct heating and cooling of heat regulation centers on body temperature

    NASA Technical Reports Server (NTRS)

    Barbour, H. G.

    1978-01-01

    Experiments were done on 28 rabbits in which puncture instruments were left in the brain for 1-2 days until the calori-puncture hyperthermia had passed and the body temperature was again normal. The instrument remaining in the brain was then used as a galvanic electrode and a second fever was produced, this time due to the electrical stimulus. It was concluded that heat is a centrally acting antipyretic and that cold is a centrally acting stimulus which produces hyperpyrexia cold-induced fever.

  20. Impression Testing of Self-Healing Polymers

    NASA Technical Reports Server (NTRS)

    Hinkley, Jeffrey A.; Huber, Amy

    2005-01-01

    As part of the BIOSANT program (biologically-inspired smart nanotechnology), scientists at NASA-Langley have identified a "self-healing" plastic that spontaneously closes the hole left by the passage of a bullet. To understand and generalize the phenomenon in question, the mechanical properties responsible for this ability are being explored. Low-rate impression testing was chosen to characterize post-yield material properties, and it turned out that materials that heal following ballistic puncture also show up to 80% healing of the low-rate impression. Preliminary results on the effects of temperature and rate of puncture are presented.

  1. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL)

    PubMed Central

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-01-01

    Background & objectives: With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Methods: Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. Results: In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Interpretation & conclusions: Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method. PMID:24820832

  2. Unenhanced low-dose versus standard-dose CT localization in patients with upper urinary calculi for minimally invasive percutaneous nephrolithotomy (MPCNL).

    PubMed

    Licheng, Jiang; Yidong, Fan; Ping, Wang; Keqiang, Yan; Xueting, Wang; Yingchen, Zhang; Lei, Gao; Jiyang, Ding; Zhonghua, Xu

    2014-03-01

    With the ethical concern about the dose of CT scan and wide use of CT in protocol of suspected renal colic, more attention has been paid to low dose CT. The aim of the present study was to make a comparison of unenhanced low-dose spiral CT localization with unenhanced standard-dose spiral CT in patients with upper urinary tract calculi for minimally invasive percutaneous nephrolithotomy (MPCNL) treatment. Twenty eight patients with ureter and renal calculus, preparing to take MPCNL, underwent both abdominal low-dose CT (25 mAs) and standard-dose CT (100 mAs). Low-dose CT and standard-dose CT were independently evaluated for the characterization of renal/ureteral calculi, perirenal adjacent organs, blood vessels, indirect signs of renal or ureteral calculus (renal enlargement, pyeloureteral dilatation), and the indices of localization (percutaneous puncture angulation and depth) used in the MPCNL procedure. In all 28 patients, low-dose CT was 100 per cent coincidence 100 per cent sensitive and 100 per cent specific for depicting the location of the renal and ureteral calculus, renal enlargement, pyeloureteral dilatation, adjacent organs, and the presumptive puncture point and a 96.3 per cent coincidence 96 per cent sensitivity and 93 per cent specificity for blood vessel signs within the renal sinus, and with an obvious lower radiation exposure for patients when compared to standard-dose CT (P<0.05). The indices of puncture depth, puncture angulation, and maximum calculus transverse diameter on the axial surface showed no significant difference between the two doses of CT scans, with a significant variation in calculus visualization slice numbers (P<0.05). Our findings show that unenhanced low-dose CT achieves a sensitivity and accuracy similar to that of standard-dose CT in assessing the localization of renal ureteral calculus and adjacent organs conditions and identifying the maximum calculus transverse diameter on the axial surface, percutaneous puncture depth, and angulation in patients, with a significant lower radiation exposure, who are to be treated by MPCNL, and can be used as an alternative localization method.

  3. Significance of preoperative planning software for puncture and channel establishment in percutaneous endoscopic lumbar DISCECTOMY: A study of 40 cases.

    PubMed

    Hu, Zhouyang; Li, Xinhua; Cui, Jian; He, Xiaobo; Li, Cong; Han, Yingchao; Pan, Jie; Yang, Mingjie; Tan, Jun; Li, Lijun

    2017-05-01

    Preoperative planning software has been widely used in many other minimally invasive surgeries, but there is a lack of information describing the clinical benefits of existing software applied in percutaneous endoscopic lumbar discectomy (PELD). This study aimed to compare the clinical efficacy of preoperative planning software in puncture and channel establishment of PELD with routine methods in treating lumbar disc herniation (LDH). From June 2016 to October 2016, 40 patients who had single L4/5 or L5/S1 disc herniation were divided into two groups. Group A adopted planning software for preoperative puncture simulation while Group B took routine cases discussion for making puncture plans. The channel establishment time, operative time, fluoroscopic times and complications were compared between the two groups. The surgical efficacy was evaluated according to the Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) and modified Macnab's criteria. The mean channel establishment time was 25.1 ± 4.2 min and 34.6 ± 5.4 min in Group A and B, respectively (P < 0.05). The mean operative time was 80.8 ± 8.4 min and 92.1 ± 7.3 min in Group A and B, respectively (P < 0.05). The fluoroscopic times were 21.5 ± 5.2 in Group A and 29.3 ± 5.5 in Group B (P < 0.05). There were no significant differences in VAS and ODI scorings between the two groups either preoperatively or postoperatively (P > 0.05). The findings of modified Macnab's criteria at each follow-up also showed no significant differences (P > 0.05). The application of preoperative planning software in puncture and cannula insertion planning in PELD was easy and reliable, and could reduce the channel establishment time, operative time and fluoroscopic times of PELD significantly. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  4. Surgical glove perforation in cardiac surgery.

    PubMed

    Driever, R; Beie, M; Schmitz, E; Holland, M; Knapp, M; Reifschneider, H J; Hofmann, F; Vetter, H O

    2001-12-01

    Recently, concern for the protection of health care employees and health care recipients has led to increasing awareness of transmitted infections. Sterile surgical gloves were tested to determine the incidence of perforations after being worn during procedures commonly performed by cardiac surgeons. In a prospective study conducted from January 15, 2000 through February 15, 2000, 953 gloves worn during cardiac surgery were evaluated for punctures. Pairs of sterile latex surgical gloves were collected over a period of one month. Routine tasks included mainly bypass and valve surgery. Impermeability was tested by means of a water retention test according to European standard EN 455 Part 1 performed on 954 (Manufix, Hartmann, Germany) latex gloves. A control group of 50 unused gloves was also evaluated for the presence of spontaneous leakage. Gloves were separated according to whether the wearer was an operator (254 gloves), first assistant (220 gloves), second assistant (272 gloves), or theatre nurse (207 gloves). Gloves with a known perforation occurring during the procedure were not included in the study. There were no punctures in the 50 unused gloves. Punctures were detected in 66 of 254 (26.0 %) gloves used by operators, 49 of 220 (22.3 %) used by first assistants, 25 of 272 (9.2 %) used by second assistants, and 78 of 207 (37.7 %) used by theatre nurses. Some gloves had more than one puncture, accounting for the 244 holes detected (operators 75/244 = 30.7 %; first assistants 54/244 = 22.1 %; second assistants 28/244 = 11.5 %; theatre nurses 87/244 = 35.7 %). Sites of scalpel and suture needle injuries were most commonly the thumb (27.3 %) and pointer finger (42.1 %) of the non-dominant hand, followed by, in descending order: middle finger (10.2 %), other fingers (15.7 %), palm (3.8 %) and back of the hand (0.9 %). The number of punctures that occur during cardiac operations is obviously higher than has so far been assumed. Therefore, cardiac surgeons should consider the incidence of unknown glove perforations when planning surgery in patients with infectious diseases.

  5. Comparison of 4 different types of surgical gloves used for preventing blood contact.

    PubMed

    Wittmann, Andreas; Kralj, Nenad; Köver, Jan; Gasthaus, Klaus; Lerch, Hartmut; Hofmann, Friedrich

    2010-05-01

    Needlestick injuries are always associated with a risk of infection, because these types of punctures may expose healthcare workers to a patient's blood and/or body fluids. To compare the efficacy of 4 different types of surgical gloves for preventing exposure to blood as a result of needlestick injury. For simulation of needlestick injury, a circular sample of pork skin was tightened onto a bracket, and a single finger from a medical glove was stretched over the sample. First, a powder-free surgical glove with a gel coating was used to test blood contact. Second, a glove with a patented puncture indication system was used to test blood contact with a double-gloved hand. Third, 2 powder-free latex medical gloves of the same size and hand were combined for double gloving, again to test blood contact. Finally, we tested a glove with an integrated disinfectant on the inside. The punctures were carried out using diverse sharp surgical devices that were contaminated with (99)Tc-marked blood. The amount of blood contact was determined from the transmitted radioactivity. For the powder-free surgical glove with a gel coating, a mean volume of 0.048 microL of blood (standard error of the mean [SEM], 0.077 microL) was transferred in punctures with an automated lancet at a depth of 2.4 mm through 1 layer of latex. For the glove with an integrated disinfectant on the inside, the mean volume of blood transferred was 0.030 microL (SEM, 0.0056 microL) with a single glove and was 0.024 microL (SEM, 0.003 microL) with 2 gloves. For the glove with the patented puncture indication system, a mean volume of 0.024 microL (SEM, 0.003 microL) of blood was transferred. Double gloving or the use of a glove with disinfectant can result in a decrease in the volume of blood transferred. Therefore, the use of either of these gloving systems could help to minimize the risk of bloodborne infections for medical staff.

  6. Intraosseous anesthesia in hemodynamic studies in children with cardiopathy.

    PubMed

    Aliman, Ana Cristina; Piccioni, Marilde de Albuquerque; Piccioni, João Luiz; Oliva, José Luiz; Auler Júnior, José Otávio Costa

    2011-01-01

    Intraosseous (IO) access has been used with good results in emergency situations, when venous access is not available for fluids and drugs infusion. The objective of this study was to evaluate IO a useful technique for anesthesia and fluids infusion during hemodynamic studies and when peripheral intravascular access is unobtainable. The setting was an university hospital hemodynamics unit, and the subjects were twenty one infants with congenital heart disease enrolled for elective hemodynamic study diagnosis. This study compared the effectiveness of IO access in relation to IV access for infusion of anesthetics agents (ketamine, midazolam, and fentanyl) and fluids during hemodynamic studies. The anesthetic induction time, procedure duration, anesthesia recovery time, adequate hydration, and IV and IO puncture complications were compared between groups. The puncture time was significantly smaller in IO group (3.6 min) that in IV group (9.6 min). The anesthetic onset time (56.3 second) for the IV group was faster than IO group (71.3 second). No significant difference between groups were found in relation to hydration (IV group, 315.5 mL vs IO group, 293.2 mL), and anesthesia recovery time (IO group, 65.2 min vs IV group, 55.0 min). The puncture site was reevaluated after 7 and 15 days without signs of infection or other complications. Results showed superiority for IO infusion when considering the puncture time of the procedure. Due to its easy manipulation and efficiency, hydration and anesthesia by IO access was satisfactory for hemodynamic studies without the necessity of other infusion access. Copyright © 2011 Elsevier Editora Ltda. All rights reserved.

  7. Venous vascular malformations of the craniofacial region: pre-operative embolisation with direct percutaneous puncture and N-butyl cyanoacrylate.

    PubMed

    Cil, B E; Vargel, I; Geyik, S; Peynircioglu, B; Cavusoglu, T

    2008-12-01

    Craniofacial venous vascular malformations cause severe cosmetic problems and yet these lesions are not candidates for transcatheter embolisation owing to the lack of arterial feeders. The purpose of this study was to evaluate the effectiveness of pre-operative embolisation of these lesions with N-butyl 2-cyanoacrylate (NBCA) via direct puncture. Between September 2003 and April 2006, 13 patients (7 female; age range, 6-64 years; mean, 16.7 years) were embolised with direct puncture and injection of NBCA. All of the patients were referred from plastic surgery with an operational plan. Angiography performed in all patients showed no or little arterial staining. NBCA diluted with iodized oil at a ratio of 1:6 (18%) was injected via a percutaneously placed 21 gauge needle. Complete embolisation was achieved in 8 patients and partial embolisation in the remaining 5. A total of 18 sessions of embolisation were performed on 13 patients. Nine patients underwent only one embolisation session, three patients underwent two sessions and only one patient underwent three sessions. The mean volume of NBCA used per session was 5.8 ml, ranging from 1-12 ml. All patients underwent a successful surgical resection to improve cosmetic disfigurement within 10-15 days after the embolisation procedure. Mean follow-up time was 22 months. One patient experienced skin necrosis on her nose after embolisation. No other complications related to the procedure were observed. In conclusion, pre-operative NBCA embolisation with direct puncture is a safe and easy procedure. It can increase the success of the surgical treatment of these lesions.

  8. Feasibility of an endotracheal tube-mounted camera for percutaneous dilatational tracheostomy.

    PubMed

    Grensemann, J; Eichler, L; Hopf, S; Jarczak, D; Simon, M; Kluge, S

    2017-07-01

    Percutaneous dilatational tracheostomy (PDT) in critically ill patients is often led by optical guidance with a bronchoscope. This is not without its disadvantages. Therefore, we aimed to study the feasibility of a recently introduced endotracheal tube-mounted camera (VivaSight™-SL, ET View, Misgav, Israel) in the guidance of PDT. We studied 10 critically ill patients who received PDT with a VivaSight-SL tube that was inserted prior to tracheostomy for optical guidance. Visualization of the tracheal structures (i.e., identification and monitoring of the thyroid, cricoid, and tracheal cartilage and the posterior wall) and the quality of ventilation (before puncture and during the tracheostomy) were rated on four-point Likert scales. Respiratory variables were recorded, and blood gases were sampled before the interventions, before the puncture and before the insertion of the tracheal cannula. Visualization of the tracheal landmarks was rated as 'very good' or 'good' in all but one case. Monitoring during the puncture and dilatation was also rated as 'very good' or 'good' in all but one. In the cases that were rated 'difficult', the visualization and monitoring of the posterior wall of the trachea were the main concerns. No changes in the respiratory variables or blood gases occurred between the puncture and the insertion of the tracheal cannula. Percutaneous dilatational tracheostomy with optical guidance from a tube-mounted camera is feasible. Further studies comparing the camera tube with bronchoscopy as the standard approach should be performed. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  9. Balancing Bacteria-Osteoblast Competition through Selective Physical Puncture and Biofunctionalization of ZnO/Polydopamine/Arginine-Glycine-Aspartic Acid-Cysteine Nanorods.

    PubMed

    Li, Jun; Tan, Lei; Liu, Xiangmei; Cui, Zhenduo; Yang, Xianjin; Yeung, Kelvin Wai Kwok; Chu, Paul K; Wu, Shuilin

    2017-11-28

    Bacterial infection and lack of bone tissue integration are two major concerns of orthopedic implants. In addition, osteoinductivity often decreases and toxicity may arise when antibacterial agents are introduced to increase the antibacterial ability. Here hybrid ZnO/polydopamine (PDA)/arginine-glycine-aspartic acid-cysteine (RGDC) nanorod (NR) arrays are designed and prepared on titanium (Ti) implants to not only enhance the osteoinductivity but also effectively kill bacteria simultaneously, which are ascribed to the selective physical puncture and the biofunctionalization of ZnO/PDA/RGDC nanorods during the competition between bacteria and osteoblasts. That is, owing to the much larger size of osteoblasts than bacteria, the hybrid NRs can puncture bacteria but not damage osteoblasts. Meanwhile, the cytocompatibility can be enhanced through the suppression of both reactive oxygen species and higher Zn 2+ concentration by the covering of PDA and RGDC. The in vitro results confirm the selective puncture of the bacterial membrane and the better osteoinductivity. In vivo tests also show much higher antibacterial efficacy of the hybrid NRs with far less amounts of lobulated neutrophils and adherent bacteria in the surrounding tissues. In addition, the hybrid NRs also accelerate formation of new bone tissues (20.1% higher than pure Ti) and osteointegration between implants and newly formed tissues (32.0% higher than pure Ti) even in the presence of injected bacteria. This work provides a surface strategy for designing implants with desirable ability of osseointegration and infection prevention simultaneously, which will exhibit tremendous clinical potential in orthopedic and dental applications.

  10. Ultrasound-guided injection for MR arthrography of the hip: comparison of two different techniques.

    PubMed

    Kantarci, Fatih; Ozbayrak, Mustafa; Gulsen, Fatih; Gencturk, Mert; Botanlioglu, Huseyin; Mihmanli, Ismail

    2013-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for MR arthrography of the hip. Fifty-nine consecutive patients (21 men, 38 women) referred for MR arthrographies of the hip were prospectively included in the study. Three patients underwent bilateral MR arthrography. The two injection techniques were quantitatively and qualitatively compared. Quantitative analysis was performed by the comparison of injected contrast material volume into the hip joint. Qualitative analysis was performed with regard to extraarticular leakage of contrast material into the soft tissues. Extraarticular leakage of contrast material was graded as none, minimal, moderate, or severe according to the MR images. Each patient rated discomfort after the procedure using a visual analogue scale (VAS). The injected contrast material volume was less in femoral head puncture technique (mean 8.9 ± 3.4 ml) when compared to femoral neck puncture technique (mean 11.2 ± 2.9 ml) (p < 0.05). The chi-squared test showed significantly more contrast leakage by femoral head puncture technique (p < 0.05). Statistical analysis showed no difference between the head and neck puncture groups in terms of feeling of pain (p = 0.744) or in the body mass index (p = 0.658) of the patients. The femoral neck injection technique provides high intraarticular contrast volume and produces less extraarticular contrast leakage than the femoral head injection technique when US guidance is used for MR arthrography of the hip.

  11. A 2-microm continuous-wave laser system for safe and high-precision dissection during NOTES procedures.

    PubMed

    Dray, Xavier; Donatelli, Gianfranco; Krishnamurty, Devi Mukkai; Dubcenco, Elena; Wroblewski, Ronald J; Assumpcao, Lia; Giday, Samuel A; Buscaglia, Jonathan M; Shin, Eun J; Magno, Priscilla; Pipitone, Laurie J; Marohn, Michael R; Kantsevoy, Sergey V; Kalloo, Anthony N

    2010-09-01

    Lasers 2-microm in wavelength offer efficient tissue cutting with limited thermal damage in biological tissue. To evaluate the dissection capabilities of a 2-microm continuous-wave laser for NOTES procedures. We conducted 18 acute animal experiments. Group 1 (three animals): transcolonic access to the peritoneal cavity (15-W transcolonic laser puncture, balloon dilation over the laser probe). Group 2 (six animals): transcolonic access with needle-knife puncture and balloon dilation. Group 3 (three animals): transgastric access to the peritoneal cavity (similar technique as group 1) followed by laser-assisted dissection of the kidney. In one animal of group 3, a therapeutic target (hematoma) was created by percutaneous puncture of the kidney. Group 4 (six animals): transgastric access (similar to the technique of group 2). Translumenal access to the peritoneal cavity was achieved in 2-3 min in group 1 (significantly shorter than with the needle-knife-assisted technique, 4-5 min, p=0.02) and in 7-10 min in group 3 (compared to 6-17 min in group 4, p=0.88). In group 3, laser dissection of the parietal peritoneum and of perinephric connective tissue allowed access to the retroperitoneum with complete removal of a blood collection in the animal with puncture trauma. Laser dissection demonstrated good maneuverability, clean and rapid cutting, and excellent hemostasis. Peritoneoscopy and necropsy showed no damage of targeted tissue and surrounding organs. The 2-microm continuous-wave laser system showed promising capabilities for highly precise and safe dissection during NOTES procedures.

  12. Evaluation of Standard Loose Plastic Packaging for the Management of Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and Tribolium castaneum (Herbst) (Coleoptera: Tenebriondiae)

    PubMed Central

    Hassan, Muhammad Waqar; Gulraize; Ali, Usman; Ur Rehman, Fazal; Najeeb, Hafsa; Sohail, Maryam; Irsa, Bakhtawar; Muzaffar, Zubaria; Chaudhry, Muhammad Shafiq

    2016-01-01

    Three standard foodstuff plastic packaging namely polyethylene (PE), polypropylene (PP), and polyvinylchloride (PVC) were evaluated for management of lesser grain borer Rhyzopertha dominica (F.) (Coleoptera: Bostrichidae) and red flour beetle Tribolium castaneum (Herbst) (Coleoptera: Tenebrionidae). Resistance parameters in packaging were recorded as punctures, holes, penetrations, sealing defects, and invasions with two thicknesses and tested for two lengths of time. Damages like punctures, holes and penetrations by both insects were more in PE packaging however R. dominica made more penetrations in PP than in PE. For both insects sealing defects and invasions were predominant in PVC than in others. Thickness did not affect significantly damage types but significantly more holes and penetrations by R. dominica were in less thickness. Punctures and holes by R. dominica were more after less time period but other damages in packaging were more after more time period. However for T. castaneum all sorts of damages were seen more after more time period. Overall categorization between two insects showed R. dominica made more penetrations and T. castaneum made more invasions compared with their counterparts. Pictures were taken under camera fitted microscope to magnify punctures and holes in different packaging and thicknesses. Insect mortality due to phosphine was more in PP and PE packaging and least in PVC packaging and thickness effect was marginal. T. castaneum mortality was significantly more after 48 h than after 24 h. Damages extent in packaging and fumigation results showed PP to be the best of three packaging materials to manage these insects. PMID:27638958

  13. [Anatomic observation of the prostate for clinical application of local drug injection through the rectum for chronic prostatitis].

    PubMed

    Cheng, Jun-ping; Dai, Jing-xing; Liu, Yong-qian; Hong, Hui-wen; Zhang, Xiu-lian; Zhang, Mei-rong; Ye, Qiu-yue

    2003-06-01

    To provide anatomic evidences for local drug injection through the rectum for treating chronic prostatitis and observe the therapeutic effect of this treatment. Anatomic observation of the median sagittal plane of 16 male pelvic specimens was conducted, with special attention to the structures between the prostate and the rectum. The distance from the posterior wall of the prostate to the anterior wall of the rectum, the scope that allowed the entry of the puncture needle, the appropriate puncture depth, and the distance from the anus to the safe were carefully measured. Analysis of the clinical record was performed in 51 chronic prostatitis cases treated with local injection of prednisolone, antibiotic and lidocaine through the rectum. Only some fat tissues and venous plexus were found between the prostate and the anterior wall of the rectum, and the distance from posterior wall of the prostate to the anterior wall of the rectum averaged 5.773+/-0.710 mm. The scope for possible puncture was 15.408 8+/-1.438 2 mm with a depth of 15.703 1+/-0.944 1 mm. The maximum and minimum distances from the anus to the puncture were 47.594+/-2.432 mm and 35.781+/-1.850 mm, respectively. Among the 51 cases investigated, the total cure rate was 84.31%, and improvement was achieved in 13.73% of the case, with only one case (2%) failed to respond to the treatment. Local drug injection through the rectum can be ideal for the treatment of prostatitis for its safety and effectiveness.

  14. The optical "Veress-needle"--initial puncture with a minioptic.

    PubMed

    Schaller, G; Kuenkel, M; Manegold, B C

    1995-02-01

    Laparoscopic access is a necessary part of minimally invasive surgery. The double blind puncture with Veress-needle and trocar can cause lethal complications such as bowel injury, bleeding and gas-embolisation. Some authors have reported alternative techniques for laparoscopic abdominal access. Because no blind procedure can absolutely prevent injury, permanent visual control of perforated tissue layers as in open surgery should be achieved to prevent possible injury at an early stage. Previously described procedures could not fulfil all requirements to comply with this ideal, i.e. permanent visual control of abdominal wall penetration prior to establishment of pneumoperitoneum and trocar insertion without further possible damage. We designed a 2 mm fibreglass optic 250 mm in length that is inserted into a suitable cannula. Special construction allows rinsing through the cannula to clear the vision and to open spaces in the puncture track by water dissection. After incision of the skin, all layers of the abdominal wall can be visualised, including blood vessels and internal surfaces. Once the abdominal cavity is reached, the needle tip is retracted and a two-step dilation allows the trocar to be introduced via the puncture track. Only then does insufflation begin. The fibreglass optic-equipped safety needle was used for visually controlled access in 184 laparoscopic surgical procedures. After a period of training, all layers of the abdominal wall could be recognised exactly. In two patients with dense adhesions, perforation of the small bowel was diagnosed immediately by endoscopic viewing. The small injury needed no treatment, and the intended procedure was completed laparoscopically.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Dual therapeutic action of antibiotic-loaded nanosheets for the treatment of gastrointestinal tissue defects.

    PubMed

    Fujie, Toshinori; Saito, Akihiro; Kinoshita, Manabu; Miyazaki, Hiromi; Ohtsubo, Shinya; Saitoh, Daizoh; Takeoka, Shinji

    2010-08-01

    An ultra-thin polymer film (nanosheet) composed of polysaccharides (i.e., polysaccharide nanosheet) provides sufficient adhesiveness, flexibility and robustness to act as an effective wound dressing. We have recently demonstrated the sealing effect of a nanosheet on a murine cecal puncture. Nevertheless, a small percentage of bacteria penetrated the nanosheet because of its ultra-thin structure. Here, we have developed an antibiotic-loaded nanosheet to inhibit bacterial penetration and investigated its therapeutic efficacy using a model of a murine cecal puncture. Tetracycline (TC) was sandwiched between a poly(vinylacetate) (PVAc) layer and the polysaccharide nanosheet (named PVAc-TC-nanosheet). Under physiological conditions, TC was released from the nanosheet for 6 h. Microscopic observation between the interface of the PVAc-TC-nanosheet and bacteria demonstrated how its potent anti-microbial effect was achieved. In vivo studies show that overlapping therapy with the PVAc-TC-nanosheet (thickness: 177 nm) significantly increases mouse survival rate after cecal puncture as well as suppressing an increase in the intraperitoneal bacterial count and leukocyte count. 2010 Elsevier Ltd. All rights reserved.

  16. Preoperative Direct Puncture Embolization of Advanced Juvenile Nasopharyngeal Angiofibroma in Combination with Transarterial Embolization: An Analysis of 22 Consecutive Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lv Mingming, E-mail: lvmingming001@163.com; Fan, Xin-dong, E-mail: fanxindong@yahoo.com.cn; Su Lixin, E-mail: sulixin1975@126.com

    2013-02-15

    ObjectiveThis study was designed to evaluate the clinical application of preoperative auxiliary embolization for juvenile nasopharyngeal angiofibroma (JNA) by direct puncture embolization (DPE) of the tumor in combination with transarterial embolization (TAE). The study included 22 patients. An 18-gauge needle was used to puncture directly into the tumor, and 20-25 % N-butyl cyanoacrylate was injected under the guidance of fluoroscopy after confirming the placement of the needle into the JNA and no leaking into the surrounding tissue. Tumors were obstructed later via TAE. The supplying arteries of JNA were from branches of the internal carotid and external carotid arteries. Controlmore » angiography showed the obliteration of contrast stain in the entire tumor mass and the distal supplying arteries disappeared after DPE in combination with TAE. Surgical resection was performed within 4 days after embolization and none of the patients required blood transfusion. The use of DPE in combination with TAE was a safe, feasible, and efficacious method. It can devascularize effectively the JNAs and reduce intraoperative bleeding when JNAs are extirpated.« less

  17. Epidural space identification: a meta-analysis of complications after air versus liquid as the medium for loss of resistance.

    PubMed

    Schier, Robert; Guerra, Diana; Aguilar, Jorge; Pratt, Gregory F; Hernandez, Mike; Boddu, Krishna; Riedel, Bernhard

    2009-12-01

    The best method for identifying the epidural space for neuraxial blocks is controversial. We conducted this meta-analysis to test the hypothesis that loss of resistance with liquid reduces complications with epidural placement. The MEDLINE, EMBASE, and Cochrane databases were searched for prospective, randomized studies comparing air versus liquid as the medium for loss of resistance during epidural space identification in adults. Data were abstracted from 5 studies (4 obstetric and 1 nonobstetric) (n = 4422 patients) that met inclusion criteria and analyzed for the following 6 outcomes: difficult catheter insertion, paresthesia, intravascular catheter insertion, accidental dural puncture, postdural puncture headache, and partial block. The overall risk differences for adverse outcome between the different mediums were not statistically different for the obstetric population. A small, but statistically significant, risk difference for postdural puncture headache was observed when fluid was used during epidural placement for chronic pain management. Larger studies that overcome limitations of heterogeneity across studies and a relatively infrequent occurrence of complications are required to determine the optimal medium for loss of resistance during epidural block.

  18. Regenerative responses after mild heart injuries for cardiomyocyte proliferation in zebrafish

    PubMed Central

    Itou, Junji; Akiyama, Ryutaro; Pehoski, Steve; Yu, Xiaodan; Kawakami, Hiroko; Kawakami, Yasuhiko

    2014-01-01

    Background The zebrafish heart regenerates after various severe injuries. Common processes of heart regeneration are cardiomyocyte proliferation, activation of epicardial tissue and neovascularization. In order to further characterize heart regeneration processes, we introduced milder injuries and compared responses to those induced by ventricular apex resection, a widely used injury method. We used scratching of the ventricular surface and puncturing of the ventricle with a fine tungsten needle as injury inducing techniques. Results Scratching the ventricular surface induced subtle cardiomyocyte proliferation and responses of the epicardium. Endothelial cell accumulation was limited to the surface of the heart. Ventricular puncture induced cardiomyocyte proliferation, endocardial and epicardial activation and neo-vascularization, similar to the resection method. However, the degree of the responses was milder, correlating with milder injury. Sham operation induced epicardial aldh1a2 expression but not tbx18 and WT1. Conclusions Puncturing the ventricle induces responses equivalent to resection at milder degrees in a shorter time frame and would be used as simple injury model. Scratching the ventricle did not induce heart regeneration and would be used for studying wound responses to epicardium. PMID:25074230

  19. [Disposable nursing applicator-pocket of indwelling central venous catheter].

    PubMed

    Wei, Congli; Ma, Chunyuan

    2017-11-01

    Catheter related infection is the most common complication of central venous catheter, which pathogen mainly originate from the pipe joint and the skin around puncture site. How to prevent catheter infection is an important issue in clinical nursing. The utility model disclosed a "disposable nursing applicator-pocket of indwelling central venous catheter", which is mainly used for the fixation and the protection. The main structure consists of two parts, one is medical applicator to protect the skin around puncture site, and the other is gauze pocket to protect the catheter external connector. When in use, the catheter connector is fitted into the pocket, and then the applicator is applied to cover the puncture point of the skin. Integrated design of medical applicator and gauze pocket was designed to realize double functions of fixation and protection. The disposable nursing applicator-pocket is made of medical absorbent gauze (outer layer) and non-woven fabric (inner layer), which has the characteristics of comfortable, breathable, dust filtered, bacteria filtered, waterproof, antiperspirant and anti-pollution. The utility model has the advantages of simple structure, low cost, simple operation, effective protection, easy realization and popularization.

  20. Vaccine vial stopper performance for fractional dose delivery of vaccines

    PubMed Central

    Jarrahian, Courtney; Myers, Daniel; Creelman, Ben; Saxon, Eugene; Zehrung, Darin

    2017-01-01

    ABSTRACT Shortages of vaccines such as inactivated poliovirus and yellow fever vaccines have been addressed by administering reduced—or fractional—doses, as recommended by the World Health Organization Strategic Advisory Group of Experts on Immunization, to expand population coverage in countries at risk. We evaluated 3 kinds of vaccine vial stoppers to assess their performance after increased piercing from repeated withdrawal of doses needed when using fractional doses (0.1 mL) from presentations intended for full-dose (0.5 mL) delivery. Self-sealing capacity and fragmentation of the stopper were assessed via modified versions of international standard protocols. All stoppers maintained self-sealing capacity after 100 punctures. The damage to stoppers measured as the fragmentation rate was within the target of ≤ 10% of punctures resulting in a fragment after as many as 50 punctures. We concluded that stopper failure is not likely to be a concern if existing vaccine vials containing up to 10 regular doses are used up to 50 times for fractional dose delivery. PMID:28463054

  1. Music and 25% glucose pain relief for the premature infant: a randomized clinical trial.

    PubMed

    Cardoso, Maria Vera Lúcia Moreira Leitão; Farias, Leiliane Martins; de Melo, Gleicia Martins

    2014-10-01

    To analyze the total Premature Infant Pain Profile scores of premature infants undergoing arterial puncture during music and 25% glucose interventions, and to assess their association with neonatal and therapeutic variables. A randomized clinical trial with 80 premature infants; 24 in the Experimental Group 1 (music), 33 in the Experimental Group 2 (music and 25% glucose), 23 in the Positive Control Group (25% glucose). All premature infants were videotaped and a lullaby was played for ten minutes before puncture in Experimental Groups 1 and 2; 25% glucose administered in Experimental Group 2 and the Positive Control Group two minutes before puncture. 60.0% of premature infants had moderate or maximum pain; pain scores and intervention groups were not statistically significant. Statistically significant variables: Experimental Group 1: head and chest circumference, Apgar scores, corrected gestational age; Experimental Group 2: chest circumference, Apgar scores, oxygen therapy; Positive Control group: birth weight, head circumference. Neonatal variables are associated with pain in premature infants. Brazilian Registry of Clinical Trials: UTN: U1111-1123-4821.

  2. Consensus statement on abusive head trauma in infants and young children.

    PubMed

    Choudhary, Arabinda Kumar; Servaes, Sabah; Slovis, Thomas L; Palusci, Vincent J; Hedlund, Gary L; Narang, Sandeep K; Moreno, Joëlle Anne; Dias, Mark S; Christian, Cindy W; Nelson, Marvin D; Silvera, V Michelle; Palasis, Susan; Raissaki, Maria; Rossi, Andrea; Offiah, Amaka C

    2018-05-23

    Abusive head trauma (AHT) is the leading cause of fatal head injuries in children younger than 2 years. A multidisciplinary team bases this diagnosis on history, physical examination, imaging and laboratory findings. Because the etiology of the injury is multifactorial (shaking, shaking and impact, impact, etc.) the current best and inclusive term is AHT. There is no controversy concerning the medical validity of the existence of AHT, with multiple components including subdural hematoma, intracranial and spinal changes, complex retinal hemorrhages, and rib and other fractures that are inconsistent with the provided mechanism of trauma. The workup must exclude medical diseases that can mimic AHT. However, the courtroom has become a forum for speculative theories that cannot be reconciled with generally accepted medical literature. There is no reliable medical evidence that the following processes are causative in the constellation of injuries of AHT: cerebral sinovenous thrombosis, hypoxic-ischemic injury, lumbar puncture or dysphagic choking/vomiting. There is no substantiation, at a time remote from birth, that an asymptomatic birth-related subdural hemorrhage can result in rebleeding and sudden collapse. Further, a diagnosis of AHT is a medical conclusion, not a legal determination of the intent of the perpetrator or a diagnosis of murder. We hope that this consensus document reduces confusion by recommending to judges and jurors the tools necessary to distinguish genuine evidence-based opinions of the relevant medical community from legal arguments or etiological speculations that are unwarranted by the clinical findings, medical evidence and evidence-based literature.

  3. Complications after LP related to needle type: pencil-point versus Quincke.

    PubMed

    Aamodt, A; Vedeler, C

    2001-06-01

    We studied the incidence of complications after diagnostic lumbar puncture (LP) related to needle type. A 5 months' observational study of routine diagnostic LP in 83 patients was conducted. Significantly more headache was observed after LP using thicker cutting needles (20G Quincke) compared with thinner cutting or non-cutting needles (22G Quincke or pencil-point). No significant difference in complications after LP was found between the 22G Quincke and pencil-point needles. The size of the needle and not the needle shape seems to be the main determinant for post-dural puncture headache (PDPH).

  4. Design of ACM system based on non-greedy punctured LDPC codes

    NASA Astrophysics Data System (ADS)

    Lu, Zijun; Jiang, Zihong; Zhou, Lin; He, Yucheng

    2017-08-01

    In this paper, an adaptive coded modulation (ACM) scheme based on rate-compatible LDPC (RC-LDPC) codes was designed. The RC-LDPC codes were constructed by a non-greedy puncturing method which showed good performance in high code rate region. Moreover, the incremental redundancy scheme of LDPC-based ACM system over AWGN channel was proposed. By this scheme, code rates vary from 2/3 to 5/6 and the complication of the ACM system is lowered. Simulations show that more and more obvious coding gain can be obtained by the proposed ACM system with higher throughput.

  5. Crossed-swords, capsule-pinch technique for capsulotomy in pediatric and/or loose lens cataract extraction.

    PubMed

    Snyder, Michael E; Lindsell, Luke B

    2010-02-01

    Puncturing the anterior capsule in a patient with a very soft lens, an elastic capsule, and/or deficient zonular countertraction can be challenging even with a sharp needle or blade. The crossed-swords, capsule-pinch technique capitalizes on opposing forces from 2 needles directed toward each other with a "pinch" of the capsule between their tips. This affords a controlled and facile puncture of the capsule without creating stress on the zonules or anteroposterior displacement of the lens. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Between-cycle laser system for depressurization and resealing of modified design nuclear fuel assemblies

    DOEpatents

    Bradley, John G.

    1982-01-01

    A laser beam is used to puncture fuel cladding for release of contained pressurized fission gas from plenum sections or irradiated fuel pins. Exhausted fission gases are collected and trapped for safe disposal. The laser beam, adjusted to welding mode, is subsequently used to reseal the puncture holes. The fuel assembly is returned to additional irradiation or, if at end of reactivity lifetime, is routed to reprocess. The fuel assembly design provides graded cladding lengths, by rows or arrays, such that the cladding of each component fuel element of the assembly is accessible to laser beam reception.

  7. N=2 gauge theories and degenerate fields of Toda theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanno, Shoichi; Matsuo, Yutaka; Shiba, Shotaro

    We discuss the correspondence between degenerate fields of the W{sub N} algebra and punctures of Gaiotto's description of the Seiberg-Witten curve of N=2 superconformal gauge theories. Namely, we find that the type of degenerate fields of the W{sub N} algebra, with null states at level one, is classified by Young diagrams with N boxes, and that the singular behavior of the Seiberg-Witten curve near the puncture agrees with that of W{sub N} generators. We also find how to translate mass parameters of the gauge theory to the momenta of the Toda theory.

  8. A navigation system for percutaneous needle interventions based on PET/CT images: design, workflow and error analysis of soft tissue and bone punctures.

    PubMed

    Oliveira-Santos, Thiago; Klaeser, Bernd; Weitzel, Thilo; Krause, Thomas; Nolte, Lutz-Peter; Peterhans, Matthias; Weber, Stefan

    2011-01-01

    Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.

  9. Involvement of peripheral and spinal tumor necrosis factor α in spinal cord hyperexcitability during knee joint inflammation in rats.

    PubMed

    König, Christian; Zharsky, Maxim; Möller, Christian; Schaible, Hans-Georg; Ebersberger, Andrea

    2014-03-01

    Tumor necrosis factor α (TNFα) is produced not only in peripheral tissues, but also in the spinal cord. The purpose of this study was to address the potential of peripheral and spinal TNFα to induce and maintain spinal hyperexcitability, which is a hallmark of pain states in the joints during rheumatoid arthritis and osteoarthritis. In vivo recordings of the responses of spinal cord neurons to nociceptive knee input under normal conditions and in the presence of experimental knee joint inflammation were obtained in anesthetized rats. TNFα, etanercept, or antibodies to TNF receptors were applied to either the knee joint or the spinal cord surface. Injection of TNFα into the knee joint cavity increased the responses of spinal cord neurons to mechanical joint stimulation, and injection of etanercept into the knee joint reduced the inflammation-evoked spinal activity. These spinal effects closely mirrored the induction and reduction of peripheral sensitization. Responses to joint stimulation were also enhanced by spinal application of TNFα, and spinal application of either etanercept or anti-TNF receptor type I significantly attenuated the generation of inflammation-evoked spinal hyperexcitability, which is characterized by widespread pain sensitization beyond the inflamed joint. Spinally applied etanercept did not reduce established hyperexcitability in the acute kaolin/carrageenan model. In antigen-induced arthritis, etanercept decreased spinal responses on day 1, but not on day 3. While peripheral TNFα increases spinal responses to joint stimulation, spinal TNFα supports the generation of the full pattern of spinal hyperexcitability. However, established spinal hyperexcitability may be maintained by downstream mechanisms that are independent of spinal TNFα. Copyright © 2014 by the American College of Rheumatology.

  10. Subdural Thoracolumbar Spine Hematoma after Spinal Anesthesia: A Rare Occurrence and Literature Review of Spinal Hematomas after Spinal Anesthesia.

    PubMed

    Maddali, Prasanthi; Walker, Blake; Fisahn, Christian; Page, Jeni; Diaz, Vicki; Zwillman, Michael E; Oskouian, Rod J; Tubbs, R Shane; Moisi, Marc

    2017-02-16

    Spinal hematomas are a rare but serious complication of spinal epidural anesthesia and are typically seen in the epidural space; however, they have been documented in the subdural space. Spinal subdural hematomas likely exist within a traumatically induced space within the dural border cell layer, rather than an anatomical subdural space. Spinal subdural hematomas present a dangerous clinical situation as they have the potential to cause significant compression of neural elements and can be easily mistaken for spinal epidural hematomas. Ultrasound can be an effective modality to diagnose subdural hematoma when no epidural blood is visualized. We have reviewed the literature and present a full literature review and a case presentation of an 82-year-old male who developed a thoracolumbar spinal subdural hematoma after spinal epidural anesthesia. Anticoagulant therapy is an important predisposing risk factor for spinal epidural hematomas and likely also predispose to spinal subdural hematomas. It is important to consider spinal subdural hematomas in addition to spinal epidural hematomas in patients who develop weakness after spinal epidural anesthesia, especially in patients who have received anticoagulation.

  11. Percutaneous nephrolithotomy of bilateral staghorn renal calculi in pediatric patients: 12 years experience in a tertiary care centre.

    PubMed

    Purkait, Bimalesh; Kumar, Manoj; Sokhal, Ashok Kumar; Bansal, Ankur; Sankhwar, Satya Narayan; Gupta, Ashok Kumar

    2017-08-01

    To assess the outcomes of percutaneous nephrolithotomy (PCNL) in bilateral staghorn calculi in pediatric patients, we have performed a retrospective analysis. Staghorn calculus is defined as stone that fills a greater part of the pelvic-caliceal system. Still, in developing countries, patients may present with staghorn calculus. PCNL is the preferred treatment modality for staghorn calculus both in adult and children. Our study included fifty-one pediatric patients (<15 years) of bilateral staghorn calculi from 2004 to 2015. Staged PCNL was done after 2-3 days if needed and opposite side PCNL was performed after 10-14 days. Fifty-one patients with bilateral staghorn renal calculi underwent PCNL. The mean age of the study group was 10.25 ± 2.13 (range 3-15). Mean stone burden was 778.3 + 613.4 (range 231-3850 mm 2 ). Forty-five patients underwent single puncture, twenty-two patients underwent double punctures whereas six patients underwent triple punctures during first session PCNL procedure. Most common puncture location was through the superior calyx (58.82 %). The mean operating time was 77.25 + 30.21 (range 58-145). After the first session PCNL, the success rate was 76.47 %. Thirteen patients (17 renal units) underwent relook PCNL and seven patients underwent ESWL. Overall complication noted in twenty-four (47.05 %) cases. Most of the complications were minor grade. Percutaneous nephrolithotomy for staghorn calculus in children needs expertise. PCNL in B/L staghorn renal calculus in children is safe and effective. B/L staghorn renal calculi with compromised renal function have higher chance of complications including bleeding.

  12. Mobile Interventional Stroke Teams Lead to Faster Treatment Times for Thrombectomy in Large Vessel Occlusion.

    PubMed

    Wei, Daniel; Oxley, Thomas J; Nistal, Dominic A; Mascitelli, Justin R; Wilson, Natalie; Stein, Laura; Liang, John; Turkheimer, Lena M; Morey, Jacob R; Schwegel, Claire; Awad, Ahmed J; Shoirah, Hazem; Kellner, Christopher P; De Leacy, Reade A; Mayer, Stephan A; Tuhrim, Stanley; Paramasivam, Srinivasan; Mocco, J; Fifi, Johanna T

    2017-12-01

    Endovascular recanalization treatment for acute ischemic stroke is a complex, time-sensitive intervention. Trip-and-treat is an interhospital service delivery model that has not previously been evaluated in the literature and consists of a shared mobile interventional stroke team that travels to primary stroke centers to provide on-site interventional capability. We compared treatment times between the trip-and-treat model and the traditional drip-and-ship model. We performed a retrospective analysis on 86 consecutive eligible patients with acute ischemic stroke secondary to large vessel occlusion who received endovascular treatment at 4 hospitals in Manhattan. Patients were divided into 2 cohorts: trip-and-treat (n=39) and drip-and-ship (n=47). The primary outcome was initial door-to-puncture time, defined as the time between arrival at any hospital and arterial puncture. We also recorded and analyzed the times of last known well, IV-tPA (intravenous tissue-type plasminogen activator) administration, transfer, and reperfusion. Mean initial door-to-puncture time was 143 minutes for trip-and-treat and 222 minutes for drip-and-ship ( P <0.0001). Although there was a trend in longer puncture-to-recanalization times for trip-and-treat ( P =0.0887), initial door-to-recanalization was nonetheless 79 minutes faster for trip-and-treat ( P <0.0001). There was a trend in improved admission-to-discharge change in National Institutes of Health Stroke Scale for trip-and-treat compared with drip-and-ship ( P =0.0704). Compared with drip-and-ship, the trip-and-treat model demonstrated shorter treatment times for endovascular therapy in our series. The trip-and-treat model offers a valid alternative to current interhospital stroke transfers in urban environments. © 2017 American Heart Association, Inc.

  13. Puncture point-traction method: A novel method applied for right internal jugular vein catheterization

    PubMed Central

    WU, TIANLIANG; ZANG, HONGCHENG

    2016-01-01

    The ultrasound probe and advancement of the needle during real-time ultrasound-assisted guidance of catheterization of the right internal jugular vein (RIJV) tend to collapse the vein, which reduces the success rate of the procedure. We have developed a novel puncture point-traction method (PPTM) to facilitate RIJV cannulation. The present study examined whether this method facilitated the performance of RIJV catheterization in anesthetized patients. In this study, 120 patients were randomly assigned to a group in which PPTM was performed (PPTM group, n=60) or a group in which it was not performed (non-PPTM group, n=60). One patient was excluded because of internal carotid artery puncture and 119 patients remained for analysis. The cross-sectional area (CSA), anteroposterior diameter (AD) and transverse diameter (TD) of the RIJV at the cricoid cartilage level following the induction of anesthesia and during catheterization were measured, and the number with obvious loss of resistance (NOLR), the number with easy aspiration of blood into syringe (NEABS) during advancement of the needle, and the number of first-pass punctures (NFPP) during catheterization were determined. In the non-PPTM group, the CSA was smaller during catheterization compared with that following the induction of anesthesia (P<0.01). In the PPTM group compared with the non-PPTM group during catheterization, the CSA was larger (P<0.01) and the AD (P<0.01) and TD (P<0.05) were wider; NOLR (P<0.01), NEABS (P<0.01) and NFPP (P<0.01) increased significantly. The findings from this study confirmed that the PPTM facilitated catheterization of the RIJV and improved the success rate of RIJV catheterization in anesthetized patients in the supine position. PMID:27347054

  14. Chest Seal Placement for Penetrating Chest Wounds by Prehospital Ground Forces in Afghanistan.

    PubMed

    Schauer, Steven G; April, Michael D; Naylor, Jason F; Simon, Erica M; Fisher, Andrew D; Cunningham, Cord W; Morissette, Daniel M; Fernandez, Jessie Renee D; Ryan, Kathy L

    Thoracic trauma represents 5% of all battlefield injuries. Communicating pneumothoraces resulting in tension physiology remain an important etiology of prehospital mortality. In addressing penetrating chest trauma, current Tactical Combat Casualty Care (TCCC) guidelines advocate the immediate placement of a vented chest seal device. Although the Committee on TCCC (CoTCCC) has approved numerous chest seal devices for battlefield use, few data exist regarding their use in a combat zone setting. To evaluate adherence to TCCC guidelines for chest seal placement among personnel deployed to Afghanistan. We obtained data from the Prehospital Trauma Registry (PHTR). Joint Trauma System personnel linked patients to the Department of Defense Trauma Registry, when available, for outcome data upon reaching a fixed facility. In the PHTR, we identified 62 patients with documented gunshot wound (GSW) or puncture wound trauma to the chest. The majority (74.2%; n = 46) of these were due to GSW, with the remainder either explosive-based puncture wounds (22.6%; n = 14) or a combination of GSW and explosive (3.2%; n = 2). Of the 62 casualties with documented GSW or puncture wounds, 46 (74.2%) underwent chest seal placement. Higher proportions of patients with medical officers in their chain of care underwent chest seal placement than those that did not (63.0% versus 37.0%). The majority of chest seals placed were not vented. Of patients with a GSW or puncture wound to the chest, 74.2% underwent chest seal placement. Most of the chest seals placed were not vented in accordance with guidelines, despite the guideline update midway through the study period. These data suggest the need to improve predeployment training on TCCC guidelines and matching of the Army logistical supply chain to the devices recommended by the CoTCCC. 2017.

  15. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  16. Effects of anesthesia with halothane and methoxyflurane on plasma corticosterone concentration in rats at rest and after exercise.

    PubMed

    Carlberg, K A; Gwosdow, A R; Alvin, B L

    1995-10-01

    To determine whether halothane and methoxyflurane are suitable anesthetics for cardiac puncture in studies of plasma corticosterone concentration in rats, four experiments were done. Blood samples were taken immediately after rats became anesthetized with halothane or methoxyflurane. Decapitation without anesthesia was used to determine baseline corticosterone concentration. Another group of rats was anesthetized with ether as a positive control (known to stimulate corticosterone secretion). Corticosterone values in halothane- and methoxyflurane-treated rats were not significantly different from those measured after decapitation. Corticosterone concentration in halothane-treated rats was significantly lower than that in either methoxyflurane- or ether-treated rats. Cardiac puncture was done after 3 min of exposure to each of the three anesthetics. The results indicated that there were no differences in corticosterone values among the three anesthetics, suggesting that corticosterone concentration was lower immediately after halothane was used as the anesthetic, because halothane induced anesthesia in less time than that required for activation of adrenocortical secretion. To determine whether there was a difference among anesthetics in stimulating corticosterone secretion when anesthesia was maintained for a period before blood sample collection, cardiac puncture was done after 15 min of exposure to each of the three anesthetics. Corticosterone values were similar, suggesting that any of the three anesthetics was acceptable in this situation. To determine whether halothane or methoxyflurane affected exercise-induced increases in corticosterone values, exercise-trained rats were run for 30 min; then blood samples were collected by cardiac puncture immediately after induction of anesthesia with halothane, methoxyflurane, or ether, or after decapitation without anesthesia. Corticosterone values were not different among the three anesthetics or decapitation.

  17. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

    PubMed

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong; Zhu, Du-Ming

    2017-04-01

    The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture.

  18. The effect of self-selected soothing music on fistula puncture-related pain in hemodialysis patients.

    PubMed

    Shabandokht-Zarmi, Hosniyeh; Bagheri-Nesami, Masoumeh; Shorofi, Seyed Afshin; Mousavinasab, Seyed Nouraddin

    2017-11-01

    This study was intended to examine the effect of selective soothing music on fistula puncture-related pain in hemodialysis patients. This is a randomized clinical trial in which 114 participants were selected from two hemodialysis units by means of a non-random, convenience sampling method. The participants were then allocated in three groups of music (N = 38), headphone (N = 38), and control (N = 38). The fistula puncture-related pain was measured 1 min after venipuncture procedure in all three groups. The music group listened to their self-selected and preferred music 6 min before needle insertion into a fistula until the end of procedure. The headphone group wore a headphone alone without listening to music 6 min before needle insertion into a fistula until the end of procedure. The control group did not receive any intervention from the research team during needle insertion into a fistula. The pain intensity was measured immediately after the intervention in all three groups. This study showed a significant difference between the music and control groups, and the music and headphone groups in terms of the mean pain score after the intervention. However, the analysis did not indicate any significant difference between the headphone and control groups with regard to the mean pain score after the intervention. It is concluded that music can be used effectively for pain related to needle insertion into a fistula in hemodialysis patients. Future research should investigate the comparative effects of pharmacological and non-pharmacological interventions on fistula puncture-related pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Biocompatible Injectable Hydrogel with Potent Wound Healing and Antibacterial Properties.

    PubMed

    Hoque, Jiaul; Prakash, Relekar G; Paramanandham, Krishnamoorthy; Shome, Bibek R; Haldar, Jayanta

    2017-04-03

    Two component injectable hydrogels that cross-link in situ have been used as noninvasive wound-filling devices, i.e., sealants. These materials carry a variety of functions at the wound sites, such as sealing leaks, ceasing unwanted bleeding, binding tissues together, and assisting in wound healing processes. However, commonly used sealants typically lack antibacterial properties. Since bacterial infection at the wound site is very common, bioadhesive materials with intrinsic antibacterial properties are urgently required. Herein, we report a biocompatible injectable hydrogel with inherent bioadhesive, antibacterial, and hemostatic capabilities suitable for wound sealing applications. The hydrogels were developed in situ from an antibacterial polymer, N-(2-hydroxypropyl)-3-trimethylammonium chitosan chloride (HTCC), and a bioadhesive polymer, polydextran aldehyde. The gels were shown to be active against both Gram-positive and Gram-negative bacteria, including drug-resistant ones such as methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus faecium (VRE), and β-lactam-resistant Klebsiela pneumoniae. Mechanistic studies revealed that the gels killed bacteria upon contact by disrupting the membrane integrity of the pathogen. Importantly, the gels were shown to be efficacious in preventing sepsis in a cecum ligation and puncture (CLP) model in mice. While only 12.5% of animals survived in the case of mice with punctured cecam but with no gel on the punctured area (control), 62.5% mice survived when the adhesive gel was applied to the punctured area. Furthermore, the gels were also shown to be effective in facilitating wound healing in rats and ceasing bleeding from a damaged liver in mice. Notably, the gel showed negligible toxicity toward human red blood cells (only 2-3% hemolysis) and no inflammation to the surrounding tissue upon subcutaneous implantation in mice, thus proving it as a safe and effective antibacterial sealant.

  20. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

Top