Sample records for spinous process system

  1. Morphological parameters for implantation of the screwless spring loop dynamic posterior spinous process stabilizing system.

    PubMed

    Song, Geun Soo; Lee, Yeon Soo

    2015-07-01

    This study aimed to quantify morphological characteristics of the posterior lumbar spinous process, which may affect stable implantation of screwless wire spring loops. Virtual implantations of a screwless wire spring loop onto pairs of lumbar spinous processes were performed for computed tomography (CT)-derived three-dimensional vertebral models of 40 Korean subjects. Morphological parameters of lumbar vertebrae 1 through 5 (L1-L5) were measured with regard to bone-implant interference. In males, the transspinous process fixation lengths decreased from 57.8±3.0mm to 48.8±3.2mm as the lumbar joints descend from L1-L2 to L4-L5, with those in females about 4.1±0.4mm shorter (p<0.05) than in males through all lumbar joints. The fixation angle on the sagittal plane varied from 105.0° to 101.3° relative to the transverse plane as the vertebrae descend. The clenched thickness in females was the least (6.7±1.2mm) for the L2 lower spinous process and the greatest (8.1±2.2mm) for the L4 upper spinous process; this was 1.0±10.3mm less than that for males at corresponding levels (p>0.05). The ratio of the spinous process clenched thickness to the transspinous fixation length increased from 0.133±0.016 to 0.196±0.076 for the upper spinous processes as the lumbar joints descend. The ratio of the spinous process clenched thickness to the transspinous fixation length varies, depending on gender and whether the clenched level is the upper or lower spinous process. These parameters related to the clenching fixation stability should be considered in development and implantations of the screwless wire spring loop. Copyright © 2015 Elsevier GmbH. All rights reserved.

  2. Segmentation of the spinous process and its acoustic shadow in vertebral ultrasound images.

    PubMed

    Berton, Florian; Cheriet, Farida; Miron, Marie-Claude; Laporte, Catherine

    2016-05-01

    Spinal ultrasound imaging is emerging as a low-cost, radiation-free alternative to conventional X-ray imaging for the clinical follow-up of patients with scoliosis. Currently, deformity measurement relies almost entirely on manual identification of key vertebral landmarks. However, the interpretation of vertebral ultrasound images is challenging, primarily because acoustic waves are entirely reflected by bone. To alleviate this problem, we propose an algorithm to segment these images into three regions: the spinous process, its acoustic shadow and other tissues. This method consists, first, in the extraction of several image features and the selection of the most relevant ones for the discrimination of the three regions. Then, using this set of features and linear discriminant analysis, each pixel of the image is classified as belonging to one of the three regions. Finally, the image is segmented by regularizing the pixel-wise classification results to account for some geometrical properties of vertebrae. The feature set was first validated by analyzing the classification results across a learning database. The database contained 107 vertebral ultrasound images acquired with convex and linear probes. Classification rates of 84%, 92% and 91% were achieved for the spinous process, the acoustic shadow and other tissues, respectively. Dice similarity coefficients of 0.72 and 0.88 were obtained respectively for the spinous process and acoustic shadow, confirming that the proposed method accurately segments the spinous process and its acoustic shadow in vertebral ultrasound images. Furthermore, the centroid of the automatically segmented spinous process was located at an average distance of 0.38 mm from that of the manually labeled spinous process, which is on the order of image resolution. This suggests that the proposed method is a promising tool for the measurement of the Spinous Process Angle and, more generally, for assisting ultrasound-based assessment of scoliosis progression. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Baastrup's Disease Is Associated with Recurrent of Sciatica after Posterior Lumbar Spinal Decompressions Utilizing Floating Spinous Process Procedures

    PubMed Central

    Mannoji, Chikato; Murakami, Masazumi; Kinoshita, Tomoaki; Hirayama, Jiro; Miyashita, Tomohiro; Eguchi, Yawara; Yamazaki, Masashi; Suzuki, Takane; Aramomi, Masaaki; Ota, Mitsutoshi; Maki, Satoshi; Takahashi, Kazuhisa; Furuya, Takeo

    2016-01-01

    Study Design Retrospective case-control study. Purpose To determine whether kissing spine is a risk factor for recurrence of sciatica after lumbar posterior decompression using a spinous process floating approach. Overview of Literature Kissing spine is defined by apposition and sclerotic change of the facing spinous processes as shown in X-ray images, and is often accompanied by marked disc degeneration and decrement of disc height. If kissing spine significantly contributes to weight bearing and the stability of the lumbar spine, trauma to the spinous process might induce a breakdown of lumbar spine stability after posterior decompression surgery in cases of kissing spine. Methods The present study included 161 patients who had undergone posterior decompression surgery for lumbar canal stenosis using a spinous process floating approaches. We defined recurrence of sciatica as that resolved after initial surgery and then recurred. Kissing spine was defined as sclerotic change and the apposition of the spinous process in a plain radiogram. Preoperative foraminal stenosis was determined by the decrease of perineural fat intensity detected by parasagittal T1-weighted magnetic resonance imaging. Preoperative percentage slip, segmental range of motion, and segmental scoliosis were analyzed in preoperative radiographs. Univariate analysis followed by stepwise logistic regression analysis determined factors independently associated with recurrence of sciatica. Results Stepwise logistic regression revealed kissing spine (p=0.024; odds ratio, 3.80) and foraminal stenosis (p<0.01; odds ratio, 17.89) as independent risk factors for the recurrence of sciatica after posterior lumbar spinal decompression with spinous process floating procedures for lumbar spinal canal stenosis. Conclusions When a patient shows kissing spine and concomitant subclinical foraminal stenosis at the affected level, we should sufficiently discuss the selection of an appropriate surgical procedure. PMID:27994785

  4. Baastrup's Disease Is Associated with Recurrent of Sciatica after Posterior Lumbar Spinal Decompressions Utilizing Floating Spinous Process Procedures.

    PubMed

    Koda, Masao; Mannoji, Chikato; Murakami, Masazumi; Kinoshita, Tomoaki; Hirayama, Jiro; Miyashita, Tomohiro; Eguchi, Yawara; Yamazaki, Masashi; Suzuki, Takane; Aramomi, Masaaki; Ota, Mitsutoshi; Maki, Satoshi; Takahashi, Kazuhisa; Furuya, Takeo

    2016-12-01

    Retrospective case-control study. To determine whether kissing spine is a risk factor for recurrence of sciatica after lumbar posterior decompression using a spinous process floating approach. Kissing spine is defined by apposition and sclerotic change of the facing spinous processes as shown in X-ray images, and is often accompanied by marked disc degeneration and decrement of disc height. If kissing spine significantly contributes to weight bearing and the stability of the lumbar spine, trauma to the spinous process might induce a breakdown of lumbar spine stability after posterior decompression surgery in cases of kissing spine. The present study included 161 patients who had undergone posterior decompression surgery for lumbar canal stenosis using a spinous process floating approaches. We defined recurrence of sciatica as that resolved after initial surgery and then recurred. Kissing spine was defined as sclerotic change and the apposition of the spinous process in a plain radiogram. Preoperative foraminal stenosis was determined by the decrease of perineural fat intensity detected by parasagittal T1-weighted magnetic resonance imaging. Preoperative percentage slip, segmental range of motion, and segmental scoliosis were analyzed in preoperative radiographs. Univariate analysis followed by stepwise logistic regression analysis determined factors independently associated with recurrence of sciatica. Stepwise logistic regression revealed kissing spine ( p =0.024; odds ratio, 3.80) and foraminal stenosis ( p <0.01; odds ratio, 17.89) as independent risk factors for the recurrence of sciatica after posterior lumbar spinal decompression with spinous process floating procedures for lumbar spinal canal stenosis. When a patient shows kissing spine and concomitant subclinical foraminal stenosis at the affected level, we should sufficiently discuss the selection of an appropriate surgical procedure.

  5. Torsional deformity of apical vertebra in adolescent idiopathic scoliosis.

    PubMed

    Kotwicki, Tomasz; Napiontek, Marek

    2002-01-01

    CT scans of structural thoracic idiopathic scoliosis were reviewed in nine patients admitted to our department for scoliosis surgery. The apical vertebra scans were chosen and the following parameters were evaluated: 1) alpha angle formed by the axis of vertebra and the axis of spinous process 2) beta concave and beta convex angle between the spinous process and the left and right transverse process, respectively, 3) gamma concave and gamma convex angle between the axis of vertebra and the left and right transverse process, respectively, 4) the rotation angle to the sagittal plane. The constant deviation of the spinous process towards the convex side of the curve was observed. The vertebral body itself was distorted towards the concavity of the curve. The angle between the spinous process and the transverse process was smaller on the convex side of the curve. The torsional, intravertebral deformity of the apical vertebra was a factor acting in the direction opposite to the rotation, in the sense to reduce the deformity of the spine in idiopathic scoliosis.

  6. Cytokeratin expression in pseudoepitheliomatous hyperplasia of oral paracoccidioidomycosis.

    PubMed

    Kaminagakura, E; Bonan, P R F; Lopes, M A; Almeida, O P; Scully, C

    2006-08-01

    Paracoccidioidomycosis (Pmycosis) is one the most prevalent deep systemic mycoses in Latin America. It is characterized by granulomatous inflammation and pseudoepitheliomatous hyperplasia. Cytokeratins (CKs) are a group of intermediate filaments of epithelial cells and their expression varies according to the epithelium type, differentiation and pathological processes. This study describes cytokeratin expression as examined by immunohistochemistry, in 28 cases of oral Pmycosis involving the buccal mucosa, lip, gingiva and hard palate. Expression of CKs in the basal layer of the epithelium in pseudoepitheliomatous hyperplasia of Pmycosis was similar to that in normal oral mucosa (NOM), but in Pmycosis CK1 and CK10 were not expressed in the spinous and superficial layers of the lip, gingiva or hard palate, and, in the spinous and superficial layers of the lip and buccal mucosa, CK14 was positive in contrast to NOM where it was negative. In Pmycosis, CK6 was more frequently expressed in the spinous layer of the lip, gingiva and hard palate, but nevertheless CK16 expression was decreased in the spinous and superficial layers of the gingiva and hard palate. We conclude that pseudoepitheliomatous hyperplasia in oral Pmycosis shows a different pattern of CK expression, particularly CKs 1, 10 and 14, compared with NOM.

  7. Use of C2 spinous process screw for posterior cervical fixation as substitute for laminar screw in a patient with thin laminae

    PubMed Central

    Nagata, Kosei; Baba, Satoshi; Chikuda, Hirotaka; Takeshita, Katsushi

    2013-01-01

    Rigid screw fixation of C2 including transarticular screw and pedicle screw contain the risk of vertebral artery (VA) injury. On the other hand, translaminar screws are considered to be safer for patients with anomalous VA. But C2 translaminar screw placement was limited in patients who have thin laminas and there is marked variation in C2 laminar thickness. Appropriate C2 fixation method for a patient who has thin laminas and high-riding VA together was controversial. Here, we present a case of an elderly Asian woman who had thin laminas and high-riding VA together with progressive myelopathy to report a first case of C2 spinous process screw insertion. Although the stability and safety of C2 spinous process screw was reported in cadaver series, there was no clinical report to our knowledge. Spinous process screw can be an option of C2 fixation for patients with high-riding VA and severe degenerated cervical spines including thin C2 laminas. PMID:23814004

  8. Morphologic and biomechanical comparison of spinous processes and ligaments from scoliotic and kyphotic patients.

    PubMed

    Beaubien, Brian P; Freeman, Andrew L; Buttermann, Glenn R

    2016-01-25

    The spinous processes and supraspinous and interspinous ligaments (SSL and ISL, respectively) limit flexion and may relate to spinal curvature. Spinous process angles and mechanical properties of explanted human thoracic posterior SSL/ISL complexes were compared for scoliosis (n=14) vs. kyphosis (n=8) patients. The median thoracic coronal Cobb angle for scoliosis patients was 48°, and sagittal angles for kyphosis patients was 78°. Spinous processes were gripped and four strain steps of 4% were applied and held. Percent relaxation was calculated over each step, equilibrium load data were fit to an exponential equation, and a Kelvin model was fit to the load from all four curves. Failure testing was also performed. Median ligament complex dimensions from scoliosis and kyphosis patients were, respectively: ISL width=16.5mm and 16.0mm; SSL width=4.3mm and 3.8mm; ISL+SSL area=17.2mm and 25.7mm; these differences were not significant. Significant differences did exist in terms of spinous process angle vs. spine axis (47° for scoliosis and 32° for kyphosis) and SSL thickness (2.1mm for scoliosis and 3.0mm for kyphosis). Fourth-step median relaxation was 42% for scoliosis and 49% for kyphosis. Median linear region stiffness was 42N/mm for scoliosis and 51N/mm for kyphosis. Median failure load was 191N for scoliotic and 175N for kyphotic ligaments. Differences in loading, relaxation, viscoelastic and failure parameters were not statistically significant, except for a trend for greater initial rate of relaxation (T1) for scoliosis ligaments. However, we found significant morphological differences related to the spinous processes, which suggests a need for future biomechanical studies related to the musculoskeletal aspects of spinal alignment and posture. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Biomechanics of lateral lumbar interbody fusion constructs with lateral and posterior plate fixation: laboratory investigation.

    PubMed

    Fogel, Guy R; Parikh, Rachit D; Ryu, Stephen I; Turner, Alexander W L

    2014-03-01

    Lumbar interbody fusion is indicated in the treatment of degenerative conditions. Laterally inserted interbody cages significantly decrease range of motion (ROM) compared with other cages. Supplemental fixation options such as lateral plates or spinous process plates have been shown to provide stability and to reduce morbidity. The authors of the current study investigate the in vitro stability of the interbody cage with a combination of lateral and spinous process plate fixation and compare this method to the established bilateral pedicle screw fixation technique. Ten L1-5 specimens were evaluated using multidirectional nondestructive moments (± 7.5 N · m), with a custom 6 degrees-of-freedom spine simulator. Intervertebral motions (ROM) were measured optoelectronically. Each spine was evaluated under the following conditions at the L3-4 level: intact; interbody cage alone (stand-alone); cage supplemented with lateral plate; cage supplemented with ipsilateral pedicle screws; cage supplemented with bilateral pedicle screws; cage supplemented with spinous process plate; and cage supplemented with a combination of lateral plate and spinous process plate. Intervertebral rotations were calculated, and ROM data were normalized to the intact ROM data. The stand-alone laterally inserted interbody cage significantly reduced ROM with respect to the intact state in flexion-extension (31.6% intact ROM, p < 0.001), lateral bending (32.5%, p < 0.001), and axial rotation (69.4%, p = 0.002). Compared with the stand-alone condition, addition of a lateral plate to the interbody cage did not significantly alter the ROM in flexion-extension (p = 0.904); however, it was significantly decreased in lateral bending and axial rotation (p < 0.001). The cage supplemented with a lateral plate was not statistically different from bilateral pedicle screws in lateral bending (p = 0.579). Supplemental fixation using a spinous process plate was not significantly different from bilateral pedicle screws in flexion-extension (p = 0.476). The combination of lateral plate and spinous process plate was not statistically different from the cage supplemented with bilateral pedicle screws in all the loading modes (p ≥ 0.365). A combination of lateral and spinous process plate fixation to supplement a laterally inserted interbody cage helps achieve rigidity in all motion planes similar to that achieved with bilateral pedicle screws.

  10. A novel technique of intra-spinous process injection of PMMA to augment the strength of an inter-spinous process device such as the X STOP.

    PubMed

    Idler, Cary; Zucherman, James F; Yerby, Scott; Hsu, Ken Y; Hannibal, Matthew; Kondrashov, Dimitriy

    2008-02-15

    Biomechanical. To determine if cement injection into the spinous process will improve compression strength. The X STOP (St. Francis Medical Technologies) has been shown to be a safe and effective means for decompressing 1- or 2-level lumbar spinal stenosis (LSS). The X STOP is indicated for LSS patients with osteoporosis, but contraindicated for patients with severe osteoporosis. In an attempt to address these LSS patients with demonstrably weaker bone, a technique to strengthen the spinous process with polymethylmethacrylate (PMMA) injection is presented. Nine pairs of adjacent fresh frozen cadaveric lumbar vertebrae were DEXA scanned before testing. They were randomly assigned to the PMMA group and a control group. Nine of the specimens were injected with PMMA. Each spinous process was then compressed between 2 X STOPs. The testing model was designed to simulate the loading of a 2-level X STOP placement. The mean load to failure and stiffness values of the treated and untreated groups were calculated. The specimens were inspected carefully for PMMA infiltration and extrusion. The mean bone mineral density (BMD) values of the control and PMMA treatment groups were 0.99 +/- 0.13 g/cm and 0.98 +/- 0.10 g/cm, respectively; P > 0.616. The mean volume of cement injected was 2.2 +/- 0.3 cc. The mean failure load values of the control and PMMA treatment groups were 1250 +/- 627 N and 2386 +/- 1034 N, respectively; P < 0.001. The mean stiffness values of the control and PMMA treatment groups were 296 +/- 139 N/mm and 381 +/- 131 N/mm, respectively; P > 0.059. Most specimens had flow of the cement into the laminae and some into the facet and pedicle. No PMMA was found within the spinal canal. This first reported technique of posterior element vertebroplasty may increase the indications and success for patients with decreased BMD who seek an interspinous implant such as the X STOP. A possible role may exist in increasing the effectiveness of such devices. However, clinical trials have yet been performed. These results demonstrate that PMMA injection in the spinous processes is effective in increasing resistance to compressive forces in an X STOP model.

  11. Heterogeneity in the development of the vertebra.

    PubMed

    Monsoro-Burq, A H; Bontoux, M; Teillet, M A; Le Douarin, N M

    1994-10-25

    Vertebrae are derived from the sclerotomal moities of the somites. Sclerotomal cells migrate ventrally to surround the notochord, where they form the vertebral body, and dorsolaterally to form the neural arch, which is dorsally closed by the spinous process. Precursor cells of the spinous process as well as superficial ectoderm and roof plate express homeobox genes of the Msh family from embryonic day 2 (E2) to E6. The notochord has been shown to be responsible for the dorsoventral polarization of the somites and for the induction of sclerotomal cells into cartilage. Indeed, supernumerary notochord grafted laterally to the neural tube induces the conversion of the entire somite into cartilage. We report here that a mediodorsal graft of notochord prevents the sclerotomal cells migrating dorsally to the roof plate from differentiating into cartilage. Under these experimental conditions, expression of Msx genes is abolished. We thus demonstrate that cartilaginous, differentiation is differentially controlled in the dorsal part of the vertebra (spinous process) and in the neural arch and vertebral body.

  12. Minimally Invasive Removal of an Intradural Cervical Tumor : Assessment of a Combined Split-Spinous Laminectomy and Quadrant Tube Retractor System Technique

    PubMed Central

    Kwak, Young-Seok; Cho, Dae-Chul; Kim, Young-Baeg

    2012-01-01

    Conventional laminectomy is the most popular technique for the complete removal of intradural spinal tumors. In particular, the central portion intramedullary tumor and large intradural extramedullary tumor often require a total laminectomy for the midline myelotomy, sufficient decompression, and adequate visualization. However, this technique has the disadvantages of a wide incision, extensive periosteal muscle dissection, and bony structural injury. Recently, split-spinous laminectomy and tubular retractor systems were found to decrease postoperative muscle injuries, skin incision size and discomfort. The combined technique of split-spinous laminectomy, using a quadrant tube retractor system allows for an excellent exposure of the tumor with minimal trauma of the surrounding tissue. We propose that this technique offers possible advantages over the traditional open tumor removal of the intradural spinal cord tumors, which covers one or two cervical levels and requires a total laminectomy. PMID:23133739

  13. C6 Spinous Process Fracture in a Young Adult.

    PubMed

    Watson, Daniel J; Dolbeer, Jeffery A

    2017-09-01

    A 21-year-old male military academy cadet developed acute posterior neck pain after performing multiple sets of overhead shoulder presses and resting the bar on his lower neck and shoulders. He presented to a direct-access physical therapy clinic. Due to the acute onset and focal nature of pain in the setting of repetitive weightlifting, the physical therapist ordered radiographs of the cervical spine, which revealed a C6 spinous process fracture. J Orthop Sports Phys Ther 2017;47(8):578. doi:10.2519/jospt.2017.7277.

  14. SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology. Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Spenciner, David; Robinson, James C

    2006-02-01

    The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion-extension ROM was ACS/SPP at 4.14 degrees whereas it was 5.75 degrees for ACS/UPSR fixation, 5.03 degrees for ACS/BPSR fixation, and 10.13 degrees for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.

  15. Transverse plane of apical vertebra of structural thoracic curve: vertebra displacement versus vertebral deformation.

    PubMed

    Kotwicki, Tomasz; Napiontek, Marek; Nowakowski, Andrzej

    2006-01-01

    CT transversal scans of the trunk provided at the level of Th8 or Th9 (apical vertebra) of 23 patients with structural thoracic scoliosis were reviewed. The following parameters were studied: 1) alpha angle formed by the axis of vertebra and the axis of spinous process, 2) beta concave and beta convex angle between the spinous process and the left and right transverse process respectively, 3) gamma concave and gamma convex angle between the axis of vertebra and the left and right transverse process respectively, 4) rotation angle to the sagittal plane according to Aaro and Dahlborn, 5) Cobb angle. Values of measured parameters demonstrated a common pattern of intravertebral deformity: counter clockwise deviation of the spinous process (alpha angle 15,0 +/-8,5 degrees), beta concave (69,8 +/-8,5 degrees) significantly greater than beta convex (38,8 +/-8,5 degrees), gamma concave (54,3 +/-7,8 degrees) not different from gamma convex (56,0 +/-8,0 degrees). Strong linear positive correlation between alpha angle and Aaro-Dahlborn angle was observed (r=0,78, p<0,05). Changes in morphology of apical vertebra due to intravertebral bone remodelling followed the vertebral spatial displacement and there existed a linear correlation in between. The two processes develop in opposite directions.

  16. Intravertebral deformation in idiopathic scoliosis: a transverse plane computer tomographic study.

    PubMed

    Kotwicki, Tomasz; Napiontek, Marek

    2008-03-01

    The scoliotic vertebrae are submitted to (1) the displacement in the 3-dimensional space and (2) the bone remodeling, which results in a 3-dimensional intrinsic vertebral deformation. Both phenomena are most expressed inside the apical zone of the curve and can be measured in a computer tomographic (CT) scan. A comparative study of CT thoracic scans in scoliotic and normal children was performed to provide a better description of the altered anatomy with respect to patomechanism of scoliosis. Twenty-three scoliotic girls, aged 14.3 +/- 2.1 years, a case of a right thoracic curve with a Cobb angle of 60.6 +/- 19.3 degrees, and 24 controls, free of spinal deformity, sex- and age-matched, underwent CT examination of the thorax at the level of Th8 to Th9 vertebra. The rotation angle of the apical vertebra and the sagittal to coronal rib cage diameters ratio were measured. The intravertebral deformation was assessed by measuring the angles between the axis of the whole vertebra and the axes of the spinous or transverse processes. The ratio of sagittal to coronal chest diameter was reduced in scoliosis patients (P < 0.001) and correlated with the Cobb angle. The angle between the axis of vertebra and the spinous process increased (P = 0.008), and its value was positively correlated with the rotation angle of the vertebra (r = 0.78, P < 0.05); however, the rotation was oriented clockwise, whereas the spinous process deviation was counterclockwise. The angle between the spinous and the transverse process revealed greater values on the concave side (P < 0.001), whereas the transverse processes were not deviated from the axis of vertebra (P = 0.469). A constant pattern, previously not described, of the alteration of morphology of the apical vertebra due to the intravertebral bone remodeling was identified. The intravertebral deformation accompanied the displacement of the vertebra with a linear correlation; however, the 2 phenomena were developing in the opposite directions. Level III, cross-sectional study.

  17. Umbilical-spinous line: a morphological term that should be included in the anatomical terminology

    PubMed Central

    Ríos, John

    2013-01-01

    We argue the need to include in the International Anatomical Terminology the term "Umbilical-spinous line" for its importance as a morphological referent in bioscopic and surface anatomy. Also, in order to avoid using eponyms, it is suggested that the traditional term "McBurney point" be replaced by "supra spinous point" as being more descriptive of location. PMID:24892620

  18. Mapping intended spinal site of care from the upright to prone position: an interexaminer reliability study.

    PubMed

    Cooperstein, Robert; Young, Morgan

    2014-01-01

    Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position. Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants. The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83. As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings.

  19. Mapping intended spinal site of care from the upright to prone position: an interexaminer reliability study

    PubMed Central

    2014-01-01

    Background Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position. Methods Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants. Results The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83. Conclusions As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings. PMID:24904747

  20. Dorsal surgical stabilisation using tension bands for treatment of traumatic atlanto-occipital instability in a cat.

    PubMed

    Vedrine, B; Maurin, M P

    2017-12-01

    An atlanto-occipital instability secondary to a dog bite was diagnosed in a 4-year-old Persian cat. Dorsal stabilisation of the instability was made with two OrthoFiber prostheses (Securos), which were used as tension bands between the nuchal crests of the occipital bone and the spinous process of the axis. Total recovery was achieved 4 days after surgery. Normal alignment of the atlanto-occipital joint was observed on survey radiographs taken 6 weeks post-surgery. Although the right loop had failed, the alignment was still normal and no neurological after-effects could be identified. Dorsal divergent tension bands between the nuchal crests of the occipital bone and the spinous process of the axis can be used to stabilise traumatic atlanto-occipital instability. © 2017 Australian Veterinary Association.

  1. Accuracy of a Radiological Evaluation Method for Thoracic and Lumbar Spinal Curvatures Using Spinous Processes.

    PubMed

    Marchetti, Bárbara V; Candotti, Cláudia T; Raupp, Eduardo G; Oliveira, Eduardo B C; Furlanetto, Tássia S; Loss, Jefferson F

    The purpose of this study was to assess a radiographic method for spinal curvature evaluation in children, based on spinous processes, and identify its normality limits. The sample consisted of 90 radiographic examinations of the spines of children in the sagittal plane. Thoracic and lumbar curvatures were evaluated using angular (apex angle [AA]) and linear (sagittal arrow [SA]) measurements based on the spinous processes. The same curvatures were also evaluated using the Cobb angle (CA) method, which is considered the gold standard. For concurrent validity (AA vs CA), Pearson's product-moment correlation coefficient, root-mean-square error, Pitman- Morgan test, and Bland-Altman analysis were used. For reproducibility (AA, SA, and CA), the intraclass correlation coefficient, standard error of measurement, and minimal detectable change measurements were used. A significant correlation was found between CA and AA measurements, as was a low root-mean-square error. The mean difference between the measurements was 0° for thoracic and lumbar curvatures, and the mean standard deviations of the differences were ±5.9° and 6.9°, respectively. The intraclass correlation coefficients of AA and SA were similar to or higher than the gold standard (CA). The standard error of measurement and minimal detectable change of the AA were always lower than the CA. This study determined the concurrent validity, as well as intra- and interrater reproducibility, of the radiographic measurements of kyphosis and lordosis in children. Copyright © 2017. Published by Elsevier Inc.

  2. Differential Structural Plasticity of Corticostriatal and Thalamostriatal Axo-Spinous Synapses in MPTP-Treated Parkinsonian Monkeys

    PubMed Central

    Villalba, Rosa M.; Smith, Yoland

    2011-01-01

    Striatal spine loss is a key pathological feature of Parkinson's disease (PD). Knowing that striatal glutamatergic afferents target dendritic spines, these data appear difficult to reconcile with evidence for an increased expression of the vesicular glutamate transporter 1 (vGluT1) in the striatum of PD patients and 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-treated monkeys, as well as in some electrophysiological studies showing overactivity of the corticostriatal glutamatergic system in models of parkinsonism. To address the possibility that structural changes in glutamatergic afferents may underlie these discrepancies, we undertook an ultrastructural analysis of vGluT1-positive (i.e., corticostriatal) and vGluT2-positive (i.e., mostly thalamostriatal) axo-spinous glutamatergic synapses using a 3D electron microscopic approach in normal and MPTP-treated monkeys. Three main conclusions can be drawn: 1) spines contacted by vGluT1-containing terminals have larger volume and harbor significantly larger postsynaptic densities (PSDs) than those contacted by vGluT2-immunoreactive boutons; 2) a subset of vGluT2-, but not vGluT1-immunoreactive, terminals display a pattern of multisynaptic connectivity in normal and MPTP-treated monkeys; and 3) VGluT1- and vGluT2-positive axo-spinous synapses undergo ultrastructural changes (larger spine volume, larger PSDs, increased PSD perforations, larger presynaptic terminal) indicative of increased synaptic activity in parkinsonian animals. Furthermore, spines contacted by cortical terminals display an increased volume of their spine apparatus in MPTP-treated monkeys, suggesting an increased protein synthesis at corticostriatal synapses. These findings demonstrate that corticostriatal and thalamostriatal glutamatergic axo-spinous synapses display significantly different ultrastructural features, and that both systems undergo complex morphological changes that could underlie the pathophysiology of corticostriatal and thalamostriatal systems in PD. PMID:21280048

  3. Unicameral bone cyst in the spinous process of a thoracic vertebra.

    PubMed

    Tsirikos, Athanasios I; Bowen, J Richard

    2002-10-01

    Unicameral bone cysts affecting the spine are extremely rare and tend to be misdiagnosed. We report on a 17-year-old female patient who presented with a 2-year history of persistent low back pain. The radiographic evaluation and bone scan failed to reveal a pathologic process. Magnetic resonance of the painful area and subsequent computed tomography scan showed a well-circumscribed osteolytic lesion originating from the spinous process and extending into both laminae of T9 vertebra. Aneurysmal bone cyst or osteoblastoma was considered to be the most probable diagnosis. The patient underwent excisional biopsy of the tumor. The intraoperative findings were suggestive of solitary bone cyst, a diagnosis that was confirmed histologically. Because the tumor had not invaded the articular facets, no posterolateral spine fusion was required. The patient had an unremarkable postoperative clinical course. Her symptoms resolved and she returned to her previous level of physical activities. Unicameral bone cysts, although uncommon, should be included in the differential diagnosis of an osteolytic lesion involving the spine.

  4. Spinous TiO₂ and Au@TiO₂ octahedral nanocages: amorphisity-to-crystallinity transition-driven surface structural construction and photocatalytic study.

    PubMed

    Li, Jie; Zu, Lianhai; Li, Ying; Jin, Chao; Qin, Yao; Shi, Donglu; Yang, Jinhu

    2014-07-15

    Novel spinous TiO2 and Au@TiO2 octahedral nanocages have been prepared through a well-designed three-step strategy including templated TiO2 wet coating, subsequent structural ripening and final template removal or transformation. The strategy is built on an amorphisity-to-crystallinity transition-driven surface structural construction, which emphasizes the critical steps of crystallization-controlled TiO2 coating and consequent structural ripening. The influence of some key parameters, such as coating temperature, ripening temperature and ripening time, on the structure and morphology of the spinous TiO2 and Au@TiO2 nanocages have been investigated. In addition, in photocatalytic measurements, the prepared spinous TiO2-based nanocages exhibit enhanced photocatalytic efficiency relative to spinousless TiO2-based nanocages as well as P-25, owing to their structure advantages resulting from spinous surfaces. The photocatalytic activity of these TiO2 based photocatalysts has been systematically studied through the corresponding ·OH radical measurements. The synthetic strategy may work as a general method, through similarly designing, to realize surface structure engineering for various materials such as metals, hydroxide and other oxides besides TiO2. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Accuracy and reliability testing of two methods to measure internal rotation of the glenohumeral joint.

    PubMed

    Hall, Justin M; Azar, Frederick M; Miller, Robert H; Smith, Richard; Throckmorton, Thomas W

    2014-09-01

    We compared accuracy and reliability of a traditional method of measurement (most cephalad vertebral spinous process that can be reached by a patient with the extended thumb) to estimates made with the shoulder in abduction to determine if there were differences between the two methods. Six physicians with fellowship training in sports medicine or shoulder surgery estimated measurements in 48 healthy volunteers. Three were randomly chosen to make estimates of both internal rotation measurements for each volunteer. An independent observer made objective measurements on lateral scoliosis films (spinous process method) or with a goniometer (abduction method). Examiners were blinded to objective measurements as well as to previous estimates. Intraclass coefficients for interobserver reliability for the traditional method averaged 0.75, indicating good agreement among observers. The difference in vertebral level estimated by the examiner and the actual radiographic level averaged 1.8 levels. The intraclass coefficient for interobserver reliability for the abduction method averaged 0.81 for all examiners, indicating near-perfect agreement. Confidence intervals indicated that estimates were an average of 8° different from the objective goniometer measurements. Pearson correlation coefficients of intraobserver reliability for the abduction method averaged 0.94, indicating near-perfect agreement within observers. Confidence intervals demonstrated repeated estimates between 5° and 10° of the original. Internal rotation estimates made with the shoulder abducted demonstrated interobserver reliability superior to that of spinous process estimates, and reproducibility was high. On the basis of this finding, we now take glenohumeral internal rotation measurements with the shoulder in abduction and use a goniometer to maximize accuracy and objectivity. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  6. Development and preclinical testing of a new tension-band device for the spine: the Loop system.

    PubMed

    Garner, Matthew D; Wolfe, Steven J; Kuslich, Stephen D

    2002-10-01

    Wire sutures, cerclage constructs, and tension bands have been used for many years in orthopedic surgery. Spinous process and sublaminar wires and other strands or cables are used in the spine to re-establish stability of the posterior spinal ligament complex. Rigid monofilament wires often fail due to weakening created during twisting or wrapping. Stronger metal cables do not conform well to bony surfaces. Polyethylene cables have higher fatigue strength than metal cables. The Loop cable is a pliable, radiolucent, polyethylene braid. Creep of the Loop/locking clip construct is similar to metal cable constructs using crimps. Both systems have less creep than knotted polyethylene cable constructs.

  7. Labial flap vaginoplasty with sacrospinous fixation.

    PubMed

    Murthy, Chandrashekar; Ashok, Kiran; Kalal, Susheel Kumar

    2010-01-01

    We present a case of congenital absence of Vagina which was treated by reconstruction of the vagina using vascular labial flaps. Furthermore, we anchored the neo-vagina to the Sacro-spinous ligament on either side. The aim of the attachment to the sacro-spinous ligament is to provide a durable apical support and to give an immediate, good vaginal length. Various techniques have been described for the construction of Neo-vagina. Except for sigmoid vaginoplasty, most other procedures are associated with a significant risk of post-operative restenosis, for which prolonged dilatation is necessary. Attaching to the sacro-spinous ligament gives the vagina good depth and, to some extent, decreases the risk of re-stenosis. This technique is simpler, does not require sophisticated instruments or prolonged post operative dilatation and is particularly suitable for under-developed countries.

  8. From fetus to adult--an allometric analysis of the giraffe vertebral column.

    PubMed

    van Sittert, Sybrand J; Skinner, John D; Mitchell, Graham

    2010-09-15

    As mammalian cervical vertebral count is almost always limited to seven, the vertebral column of the giraffe (Giraffa camelopardalis) provides an interesting study on scaling and adaptation to shape in light of these constraints. We have defined and described the growth rates of the lengths, widths, and heights of the vertebrae from fetal through neonatal life to maturity. We found that the disproportionate elongation of the cervical vertebrae is not a fetal process but occurs after birth, and that each cervical (C2-C7) vertebrae elongates at the same rate. C7 is able to specialize toward elongation as its function has been shifted to T1. We concluded that T1 is a transitional vertebra whose scaling exponent and length is between that of the cervical and thoracic series. Despite its transitional nature, T1 is still regarded as thoracic, as it possesses an articulating rib that attaches to the sternum. The other dimensions taken (width, height, and spinous process length) show that giraffe vertebral morphology exhibit adaptations to biomechanical strain, and we have underlined the importance of the thoracic spinous processes in supporting the head and neck. (c) 2010 Wiley-Liss, Inc.

  9. Chemical Blistering: Cellular and Macromolecular Components

    DTIC Science & Technology

    1985-12-15

    minutes of exposure. Warthin and Weller (2) and Sinclslr (3) noted that the process initially involves dostrurtion of the bezel and lower spinous...Clark, W. H., Jr., Risen, A. Z., Van Scott, R. J., and Vaughan, J. H., ads) McGraw-Hill, New York, pp.589-598. 2. Warthin , A. S., and Weller, C. V

  10. Lumbar Spinous Process Fixation and Fusion: A Systematic Review and Critical Analysis of an Emerging Spinal Technology.

    PubMed

    Lopez, Alejandro J; Scheer, Justin K; Dahdaleh, Nader S; Patel, Alpesh A; Smith, Zachary A

    2017-11-01

    A systematic review. The available literature on interspinous rigid fixation/fusion devices (IFD) was systematically reviewed to explore the devices' efficacy and complication profile. The clinical application of new spinal technologies may proceed without well-established evidence, as is the case with IFDs. IFDs are plate-like devices that are attached to the lateral aspects of 2 adjacent spinous processes to promote rigidity at that segment. Despite almost a decade since the devices' introduction, the literature regarding efficacy and safety is sparse. Complications have been reported but no definitive study is known to the authors. A systematic review of the past 10 years of English literature was conducted according to PRISMA guidelines. The timeframe was chosen based on publication of the first study containing a modern IFD, the SPIRE, in 2006. All PubMed publications containing MeSH headings or with title or abstract containing any combination of the words "interspinous," "spinous process," "fusion," "fixation," "plate," or "plating" were included. Exclusion criteria consisted of dynamic stabilization devices (X-Stop, DIAM, etc.), cervical spine, pediatrics, and animal models. The articles were blinded to author and journal, assigned a level of evidence by Oxford Centre of Evidence-Based Medicine (OCEBM) criteria, and summarized in an evidentiary table. A total of 293 articles were found in the initial search, of which 15 remained after examination for exclusion criteria. No class I or class II evidence regarding IFDs was found. IFDs have been shown by methodologically flawed and highly biased class III evidence to reduce instability at 1 year, without statistical comparison of complication rates against other treatment modalities. Although IFDs are heavily marketed and commonly applied in modern practice, data on safety and efficacy are inadequate. The paucity of evidence warrants reexamination of these devices' value and indications by the spine surgery community.

  11. The retrodural space of Okada.

    PubMed

    Murthy, Naveen S; Maus, Timothy P; Aprill, Charles

    2011-06-01

    The retrodural space of Okada is a potential space that can act as a conduit for the spread of inflammatory or infectious processes, connecting ipsilateral adjacent facet joints, contralateral adjacent facet joints, adjacent neural foramen, paraspinal musculature, and spinous process adventitial bursa (i.e., Baastrup disease). Awareness of these potential retrodural communications during diagnostic imaging interpretation and interventional spine injection procedures can play an important role in patient care and management.

  12. Labial flap vaginoplasty with sacrospinous fixation

    PubMed Central

    Murthy, Chandrashekar; Ashok, Kiran; Kalal, Susheel Kumar

    2010-01-01

    We present a case of congenital absence of Vagina which was treated by reconstruction of the vagina using vascular labial flaps. Furthermore, we anchored the neo-vagina to the Sacro-spinous ligament on either side. The aim of the attachment to the sacro-spinous ligament is to provide a durable apical support and to give an immediate, good vaginal length. Various techniques have been described for the construction of Neo-vagina. Except for sigmoid vaginoplasty, most other procedures are associated with a significant risk of post-operative restenosis, for which prolonged dilatation is necessary. Attaching to the sacro-spinous ligament gives the vagina good depth and, to some extent, decreases the risk of re-stenosis. This technique is simpler, does not require sophisticated instruments or prolonged post operative dilatation and is particularly suitable for under-developed countries. PMID:24591942

  13. Reliability of Entry-Level Athletic Trainers' Palpation Skills of Bony Anatomical Landmarks in the Lumbopelvic Region

    ERIC Educational Resources Information Center

    Schultz, Sarah M.; Jacobs, Michelle M.; Gorgos, Kara S.; Wasylyk, Nicole T.; Hanrahan, Sean; Van Lunen, Bonnie L.

    2015-01-01

    Context: Accuracy of locating various lumbopelvic landmarks for novice athletic trainers has not been examined. Objective: To examine reliability of novice athletic trainers for identification of the L4 spinous process and right and left posterior superior iliac spine (PSIS). Design: Cross-sectional reliability. Setting: Laboratory. Patients or…

  14. Biomechanical Evaluation of the CD HORIZON Spire Z Spinal System With Pedicle and Facet Fixation.

    PubMed

    Godzik, Jakub; Kalb, Samuel; Martinez-Del-Campo, Eduardo; Newcomb, Anna G U S; Singh, Vaneet; Walker, Corey T; Chang, Steve W; Kelly, Brian P; Crawford, Neil R

    2016-08-01

    Human cadaveric biomechanical study. The aim of this study was to evaluate the biomechanics of lumbar motion segments instrumented with the CD HORIZON Spire Z plate system (Spire Z), a posterior supplemental fixation spinous process plate, alone and with additional fixation systems. Plates and pedicle screw/rod and facet screw implants are adjuncts to fusion. The plate limits motion, improving segmental stability and the fusion microenvironment. However, the degree to which the plate contributes to overall stability when used alone or in conjunction with additional instrumentation has not been described. Standard nondestructive flexibility tests were performed in 7 L2-L5 human cadaveric spines. Spinal stability was determined as mean range of motion (ROM) in flexion/extension, lateral bending, and axial rotation. Paired comparisons were made between five conditions: (1) intact/control; (2) Spire Z; (3) Spire Z with unilateral pedicle screw/rod system (Spire Z+UPS); (4) Spire Z with unilateral facet screw system (Spire Z+UFS); and (5) Spire Z with bilateral facet screw system (Spire Z+BFS). Stiffness and ROM data were compared using one-way analysis of variance, followed by repeated-measures Holm-Šidák tests. Spire Z was most effective in limiting flexion (20% of normal) and extension (24% of normal), but less effective in reducing lateral bending and axial rotation. In lateral bending, Spire Z+BFS and Spire Z+UPS constructs were not significantly different and demonstrated greater ROM reduction compared with Spire Z+UFS and Spire Z (P < 0.001). Spire Z+BFS demonstrated greatest stiffness in axial rotation compared with Spire Z+UPS (P = 0.025), Spire Z+UFS (P = 0.001), and Spire Z (P < 0.001). Spire Z+UPS was not significantly different from Spire Z+UFS (P = 0.21), and superior to Spire Z (P = 0.013). The Spire Z spinous process plate provides excellent immediate fixation, particularly for flexion and extension. While the hybrid Spire Z+BFS screw construct afforded the greatest stability, Spire Z+UPS demonstrated considerable promise. N/A.

  15. Two new species of the genus Monstrillopsis Sars, 1921 (Copepoda: Monstrilloida: Monstrillidae) from South Korea.

    PubMed

    Lee, Jimin; Kim, Dongsung; Chang, Cheon Young

    2016-10-11

    Monstrilloid copepods of the genus Monstrillopsis Sars, 1921 are recorded from Korea, as well as from the northwestern Pacific, for the first time. Specimens were obtained using a light trap set overnight at piers or seawalls in small harbors. Males of two new species were found and are described herein with remarks on their affinities and detailed drawings and SEM photographs of their morphological features. Monstrillopsis longilobata sp. nov. is allied to M. chathamensis Suárez-Morales & Morales-Ramírez, 2009 and M. sarsi Isaac, 1974 in having the character combination of a long, claw-like apical spinous process on the male antennule and elongate genital lappets. It differs from them in having conspicuous transverse striations on the dorsal surface of the cephalothorax and extremely long male genital lappets, which extend far beyond the anterior margins of the caudal rami. Monstrillopsis coreensis sp. nov. also has a claw-like apical spinous process of the male antennule and conspicuous transverse striations on the dorsal surface of the cephalothorax, but it differs from M. longilobata in having a much longer and stronger apical spine of the antennule and a relatively shorter and undulating genital apparatus.

  16. Two domains in vertebral development: antagonistic regulation by SHH and BMP4 proteins.

    PubMed

    Watanabe, Y; Duprez, D; Monsoro-Burq, A H; Vincent, C; Le Douarin, N M

    1998-07-01

    It has previously been shown that the notochord grafted laterally to the neural tube enhances the differentiation of the vertebral cartilage at the expense of the derivatives of the dermomyotome. In contrast, the dorsomedial graft of a notochord inhibits cartilage differentiation of the dorsal part of the vertebra carrying the spinous process. Cartilage differentiation is preceded by the expression of transcription factors of the Pax family (Pax1/Pax9) in the ventrolateral domain and of the Msx family in the dorsal domain. The proliferation and differentiation of Msx-expressing cells in the dorsal precartilaginous domain of the vertebra are stimulated by BMP4, which acts upstream of Msx genes. It has previously been shown that the SHH protein arising from the notochord (and floor plate) is necessary for the survival and further development of Pax1/Pax9-expressing sclerotomal cells. We show here that SHH acts antagonistically to BMP4. SHH-producing cells grafted dorsally to the neural tube at E2 inhibit expression of Bmp4 and Msx genes and also inhibits the differentiation of the spinous process. We present a model that accounts for cartilage differentiation in the vertebra.

  17. Cooperative transformation and coexpression of bovine papillomavirus type 1 E5 and E7 proteins.

    PubMed

    Bohl, J; Hull, B; Vande Pol, S B

    2001-01-01

    Productively infected bovine fibropapillomas were examined for bovine papillomavirus type 1 (BPV-1) E7 localization. BPV-1 E7 was observed in the cytoplasm of basal and lower spinous epithelial cells, coexpressed in the cytoplasm of basal cells with the E5 oncoprotein. E7 was also observed in nucleoli throughout the basal and spinous layers but not in the granular cell layer. Ectopic expression of E7 in cultured epithelial cells gave rise to localization similar to that seen in productive fibropapillomas, with cytoplasmic and nucleolar expression observed. Consistent with the coexpression of E7 and E5 in basal keratinocytes, BPV-1 E7 cooperated with E5 as well as E6 in an anchorage independence transformation assay. While E5 is expressed in both basal and superficial differentiating keratinocytes, BPV-1 E7 is only observed in basal and lower spinous epithelial cells. Therefore, BPV-1 E7 may serve to modulate the cellular response of basal epithelial cells to E5 expression.

  18. Spinous α-Fe2O3 hierarchical structures anchored on Ni foam for supercapacitor electrodes and visible light driven photocatalysts.

    PubMed

    Zheng, Xin; Han, Zhicheng; Yao, Shunyu; Xiao, Huanhao; Chai, Fang; Qu, Fengyu; Wu, Xiang

    2016-04-28

    Spinous α-Fe2O3 hierarchical structures grown on a Ni foam substrate have been successfully obtained by a facile one-step hydrothermal method. The prepared products are functionalized as supercapacitor electrodes without adding any ancillary materials such as carbon black or binders. Their electrochemical properties show a high discharge areal capacitance (681 mF cm(-2) at 1 mA cm(-2)), good rate performance (495 mF cm(-2) at 5 mA cm(-2)) and long-term cycling stability (23.9% loss after 6000 repetitive cycles at 1 mA cm(-2)). Such excellent supercapacitive characteristics could be mainly attributed to their unique spatial structures which provide many active sites and enhance the combination between the electrode and Ni foam to support fast ion and electron transfer. In addition, the prepared α-Fe2O3 product is also used as a photocatalyst for the photocatalytic degradation of several harmful organic dyes under visible light illumination. By comparing the photocatalytic performance towards Congo red dye with other photocatalysts, it was observed that the prepared spinous α-Fe2O3 hierarchical structure exhibited superior photocatalytic performance. Finally, photocatalytic recycle tests showed the superiority of the prepared α-Fe2O3 product. This demonstrates that spinous α-Fe2O3 structures could be promising candidate materials for high-capacity, low-cost supercapacitor electrodes and environmentally friendly photocatalysts.

  19. Functional anatomy of the caudal thoracolumbar and lumbosacral spine in the horse.

    PubMed

    Stubbs, N C; Hodges, P W; Jeffcott, L B; Cowin, G; Hodgson, D R; McGowan, C M

    2006-08-01

    Research in spinal biomechanics and functional anatomy has advanced back pain research in man. Yet, despite the performance limiting nature of back pain in horses, there are few data for the equine spine. To describe aspects of functional anatomy of the equine thoracolumbar and lumbosacral (LS) spine and potential effects on performance. The first study investigated variations in LS vertebral formula by post mortem examination of 120 horses. Midline vertebral transection was carried out on 65 Thoroughbred (TB), 24 Standardbred (SB) and 31 other breeds. The second study investigated morphology and biomechanics of the deep stabilising epaxial muscles of 13 horses using MRI (n = 3), anatomical dissection (n = 11) and biomechanical analysis (n = 6). The spinous process angular orientation relative to the vertebral body, was analysed at vertebrae T13, T18, L3, L5, L6 and S1. LS variations were found in 33.3% of the total group, 40.0% TB and 45.2% others, but 0% SB. Sacralisation of lumbar vertebra (L) 6 with LS motion between L5 and L6 occurred in 32.3% TB and 29.0% others. Five segmental multifidus fascicles were identified originating from spinous processes and vertebral laminae running craniocaudally onto the mammillary processes and lateral border of the sacrum, crossing between 1-5 intervertebral discs. Sacrocaudalis dorsalis (SCD) lateralis muscle was an extension of multifidus from L4, L5 and L6 depending on the vertebral formula whereas SCD medialis mm originated from S3. Both inserted on caudal vertebrae. Based on the location and direction of fibres, the principal action of the deep epaxial muscles was dorsoventral sagittal rotation. This action was dependent on vertebral spinous process/body orientation. We hypothesise that equine multifidus and SCD lateralis muscles act as caudal sagittal rotators of their vertebra of origin, as is the case in man, allowing dynamic stabilisation during dorsoventral motion. Equine multifidus anatomy and function are comparable to that of man. The high prevalence of anatomical variations in the LS spine may affect maximal dorsoventral motion, the stability of the LS joint and, therefore, have consequences for athletic performance. Further studies of these structures are warranted in appropriately selected poorly performing horses.

  20. The effects of spinal mobilization with arm movements on shoulder muscle strengthening

    PubMed Central

    Seo, Youngjoon; Lee, Jaeseok; Han, Dongwook

    2015-01-01

    [Purpose] This study was performed to examine the immediate effects of spinal mobilization with arm movements (SMWAMs) for strengthening the shoulder muscles. [Subjects] The subjects of this study were 12 healthy male students who were studying at S University, Busan City. They had no musculoskeletal disease, or upper congenital malformation, and had no history of surgery or neurological disease. [Methods] The SMWAMs were performed on the 4th cervical vertebra (C4). For stimulation of the 5th cervical nerve, the spinous process of the C4 was pushed to the left and held in place. Then the arm was abducted to the point where spinous process was felt, and the range of abduction was examined. Subsequently, the abduction movement was repeated 10 times to the same point, and the gliding of C4 was held until the arm returned to the starting position. During the treatment, the head and the trunk were held in the correct posture. [Results] After SMWAMs had been performed, the muscular strength of shoulder flexion, extension and adduction significantly increased. [Conclusion] In our opinion, the SMWAMs are a very useful method for correcting spinal malalignment, and for stimulating the joint mechanoreceptors without the risks of manipulation. SMWAM is a valuable therapy method that can complement the demerits of mobilization. PMID:25642026

  1. Advanced Prosthetic Gait Training Tool

    DTIC Science & Technology

    2011-09-01

    Placed above the medial border of the scapula on the level of T3 T7 T7 spinous process CLAV Placed in the center of the clavicles RCLAV, LCLAV...Right Shoulder  Right Hand B  Right Elbow  Right Toe  Right Wrist  Upper Neck    Lower Neck    Head Right    Right  Clavicle     Left  Clavicle     Head

  2. Morphometric analysis of suprabasal cells in oral white lesions.

    PubMed Central

    Shabana, A H; el-Labban, N G; Lee, K W; Kramer, I R

    1989-01-01

    Surgical specimens from the cheek mucosa of 73 patients with white lesions were studied to determine various morphometric parameters that would help differentiate between the various types of oral mucosal white lesions that carry a risk of malignant change. Four cell types were represented: traumatic keratosis, leucoplakia, candidal leucoplakia and lichen planus, in addition to a control group of normal mucosa. The shape and size of the epithelial cells in two cell compartments, parabasal and spinous, were investigated by an interactive image analysis system (IBAS-1). The results showed an increase in the cell size in the parabasal cell compartment of all the white lesions compared with the normal mucosa. In the spinous cell compartment there was an increase in the cell size in lichen planus and traumatic keratosis; leucoplakia and candidal leucoplakia showed a slight decrease in cell size compared with the normal mucosa. Attempts to discriminate between the four groups of white lesions showed that these parameters can provide a high level of separation between lichen planus and the three other groups, but not between leucoplakia, candidal leucoplakia, and traumatic keratosis. PMID:2703543

  3. Sensitivity for palpating lumbopelvic soft- tissues and bony landmarks and its associated factors: A single-blinded diagnostic accuracy study.

    PubMed

    Ferreira, A P A; Póvoa, L C; Zanier, J F C; Machado, D C; Ferreira, A S

    2017-08-03

    Evidence on the diagnostic performance of palpatory methods and possible confounding factors is scarce. To examine the sensitivity of palpatory methods for location of lumbopelvic landmarks and to assess its association with personal characteristics. Eighty-three participants (41 men, 55.6 (16.5) years, 25.9 (4.8) kg/m2 [mean (SD)]) were enrolled in this single-blinded study. Fourteen body and softy-tissue landmarks were sequentially palpated from the spinous process of L4 to the ischial tuberosity. CT-scan images were used to assess what landmark was located. Sensitivity for location was in range 22-86% for soft-tissues and 26-69% for bony landmarks. Reduction in sensitivity was observed from the quadratus lumborum to the inferior and lateral angle of the sacrum (86-26% and 75-33%, left and right sides, respectively). Palpations of L4 and L5 spinous processes were systematically more cephalic than other landmarks. Gender was weakly correlated to almost all landmarks (rp⁢b= 0.333 or weaker). Body mass index was weakly correlated to the accurate location of ILAS and quadratus lumborum, great trochanter, PSIS, and piriformis (rp⁢b=-0.307 or weaker). Systematic and propagation errors were present using sequential palpatory methods. Palpation in men was more sensitive and higher BMI was associated with lower sensitivity for lumbopelvic landmarks.

  4. A new species of Chiridota (Echinodermata: Holothuroidea: Apodida: Chiridotidae) from Japan, and First record of C. rigida from Japan.

    PubMed

    Yamana, Yusuke; Tanaka, Hayato

    2017-10-31

    A new apodid sea cucumber, Chiridota impatiens sp. nov., is described from the intertidal zone of Okinawa, Japan, and C. rigida Semper, 1867 is also described from the intertidal zone of Wakayama, as new to Japan. C. impatiens sp. nov. is approximately 60-70 mm, with 12 tentacles and 4-7 pairs of digits per tentacle, red or reddish brown in living specimens. The tentacles contain curved rod ossicles, with spinous processes and many branches in C. rigida, however, in C. impatiens sp. nov., the curved rod ossicles are crescent-shaped, sometimes distally, with spinous processes and rarely a few branches on the circumference. In both species, the body wall contains flattened rod ossicles, mostly present along the longitudinal muscle and mesentery, curved rod ossicles primarily in the body wall, and wheel ossicles only in the wheel-papillae. In C. rigida, the contents of the wheel-papillae form a hemispherical sack-shaped structures, in which the teeth-side of the wheel ossicles mostly faces towards the outside of the body. In C. impatiens sp. nov., the contents of the wheel-papillae form a cord-shaped structure (present in both preserved and living specimens), in which the teeth-side of the wheel ossicles faces various directions, and that can be induced to break through the skin of the papillae if stimulated in living specimens.

  5. A Dynamic Model of the Cervical Spine and Head

    DTIC Science & Technology

    1981-11-01

    history for -G impact accel- eration 53 13b Moment at occipital condyles for -G impact acceleration 53 14a C6-C5 axial force time history for -G impact...triangular in shape rather than round, The 1 .minae are relatively long and narrow and meet in the posterior midline to form short bifid spinous processes...concave. It is directed upward and maedially and supports the condyles of the occipital bone. This is where the nodding, or "yes" movement of the head

  6. Strength of the cervical spine in compression and bending.

    PubMed

    Przybyla, Andrzej S; Skrzypiec, Daniel; Pollintine, Phillip; Dolan, Patricia; Adams, Michael A

    2007-07-01

    Cadaveric motion segment experiment. To compare the strength in bending and compression of the human cervical spine and to investigate which structures resist bending the most. The strength of the cervical spine when subjected to physiologically reasonable complex loading is unknown, as is the role of individual structures in resisting bending. A total of 22 human cervical motion segments, 64 to 89 years of age, were subjected to complex loading in bending and compression. Resistance to flexion and to extension was measured in consecutive tests. Sagittal-plane movements were recorded at 50 Hz using an optical two-dimensional "MacReflex" system. Experiments were repeated 1) after surgical removal of the spinous process, 2) after removal of both apophyseal joints, and 3) after the disc-vertebral body unit had been compressed to failure. Results were analyzed using t tests, analysis of variance, and linear regression. Results were compared with published data for the lumbar spine. The elastic limit in flexion was reached at 8.5 degrees (SD, 1.7 degrees ) with a bending moment of 6.7 Nm (SD, 1.7 Nm). In extension, values were 9.5 degrees (SD, 1.6 degrees ) and 8.4 Nm (3.5 Nm), respectively. Spinous processes (and associated ligaments) provided 48% (SD, 17%) of the resistance to flexion. Apophyseal joints provided 47% (SD, 16%) of the resistance to extension. In compression, the disc-vertebral body units reached the elastic limit at 1.23 kN (SD, 0.46 Nm) and their ultimate compressive strength was 2.40 kN (SD, 0.96 kN). Strength was greater in male specimens, depended on spinal level and tended to decrease with age. The cervical spine has approximately 20% of the bending strength of the lumbar spine but 45% of its compressive strength. This suggests that the neck is relatively vulnerable in bending.

  7. Immunohistochemical localization of thrombomodulin in the stratified epithelium of the rat is restricted to the keratinizing epidermis.

    PubMed

    Daimon, T; Nakano, M

    1999-12-01

    The expression and function of thrombomodulin (TM), an endothelial cofactor protein for thrombin-mediated protein C activation, in the epithelium are not fully characterized. This report describes the distribution and localization of TM in the various types of epithelia in the rat by light and electron microscopic immunocytochemistry. TM showed a limited distribution and was expressed by the keratinizing stratified epithelia of the skin, tongue, and esophagus, but was not present on the non-keratinizing epithelia of the vagina, ureter, trachea, stomach, or gut. An identical pattern of TM expression was seen in mucocutaneous junctions, transitional zones from a non-keratinizing stratified epithelium to a keratinizing epithelium at the edge of the eyelid and in the anal canal. As the keratinization of the stratified epithelia proceeded, the staining intensity increased in the transitional zones. Within the keratinizing stratified epithelia, TM staining was limited to the keratinocytes of the spinous layer, the spinous cells. The subcellular localization of TM on the spinous cells was restricted to the plasma membrane facing the intercellular spaces. TM was not detectable on the desmosomes or the two membranes making up the junction, presumably the nexus. The functional significance of TM in keratinizing epithelia is discussed.

  8. Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model.

    PubMed

    Zhang, Zhenjun; Fogel, Guy R; Liao, Zhenhua; Sun, Yitao; Liu, Weiqiang

    2018-06-01

    Lateral lumbar interbody fusion using cage supplemented with fixation has been used widely in the treatment of lumbar disease. A combined fixation (CF) of lateral plate and spinous process plate may provide multiplanar stability similar to that of bilateral pedicle screws (BPS) and may reduce morbidity. The biomechanical influence of the CF on cage subsidence and facet joint stress has not been well described. The aim of this study was to compare biomechanics of various fixation options and to verify biomechanical effects of the CF. The surgical finite element models with various fixation options were constructed based on computed tomography images. The lateral plate and posterior spinous process plate were applied (CF). The 6 motion modes were simulated. Range of motion (ROM), cage stress, endplate stress, and facet joint stress were compared. For the CF model, ROM, cage stress, and endplate stress were the minimum in almost all motion modes. Compared with BPS, the CF reduced ROM, cage stress, and endplate stress in all motion modes. The ROM was reduced by more than 10% in all motion modes except for flexion; cage stress and endplate stress were reduced more than 10% in all motion modes except for rotation-left. After interbody fusion, facet joint stress was reduced substantially compared with the intact conditions in all motion modes except for flexion. The combined plate fixation may offer an alternative to BPS fixation in lateral lumbar interbody fusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. C3–6 Laminoplasty for Cervical Spondylotic Myelopathy Maintains Satisfactory Long-Term Surgical Outcomes

    PubMed Central

    Sakaura, Hironobu; Hosono, Noboru; Mukai, Yoshihiro; Iwasaki, Motoki; Yoshikawa, Hideki

    2014-01-01

    Study Design Prospective cohort study. Objective To clarify long-term surgical outcomes of C3–6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with cervical spondylotic myelopathy (CSM). Methods Twenty patients who underwent C3–6 open-door laminoplasty for CSM and who were followed for 8 to 10 years were included in this study. Myelopathic symptoms were assessed using Japanese Orthopaedic Association (JOA) score. Axial neck pain was graded as severe, moderate, or mild. C2–7 angle was measured using lateral radiographs of the cervical spine before surgery and at final follow-up. Results Mean JOA score before surgery (11.7) was significantly improved to 15.2 at the time of maximum recovery (1 year after surgery), declining slightly to 14.9 by the latest follow-up. Late deterioration of JOA score developed in eight patients, but was unrelated to the cervical spine lesions in each case. No patient suffered from prolonged postoperative axial neck pain at final follow-up. The mean C2–7 angle before surgery (13.8 degrees) significantly increased to 19.2 degrees at final follow-up. Conclusions C3–6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with CSM maintained satisfactory long-term neurologic improvement with significantly reduced frequencies of prolonged postoperative axial neck pain and loss of C2–7 angle after surgery. PMID:25083358

  10. C3-6 laminoplasty for cervical spondylotic myelopathy maintains satisfactory long-term surgical outcomes.

    PubMed

    Sakaura, Hironobu; Hosono, Noboru; Mukai, Yoshihiro; Iwasaki, Motoki; Yoshikawa, Hideki

    2014-08-01

    Study Design Prospective cohort study. Objective To clarify long-term surgical outcomes of C3-6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with cervical spondylotic myelopathy (CSM). Methods Twenty patients who underwent C3-6 open-door laminoplasty for CSM and who were followed for 8 to 10 years were included in this study. Myelopathic symptoms were assessed using Japanese Orthopaedic Association (JOA) score. Axial neck pain was graded as severe, moderate, or mild. C2-7 angle was measured using lateral radiographs of the cervical spine before surgery and at final follow-up. Results Mean JOA score before surgery (11.7) was significantly improved to 15.2 at the time of maximum recovery (1 year after surgery), declining slightly to 14.9 by the latest follow-up. Late deterioration of JOA score developed in eight patients, but was unrelated to the cervical spine lesions in each case. No patient suffered from prolonged postoperative axial neck pain at final follow-up. The mean C2-7 angle before surgery (13.8 degrees) significantly increased to 19.2 degrees at final follow-up. Conclusions C3-6 laminoplasty preserving muscles attached to the C2 and C7 spinous processes in patients with CSM maintained satisfactory long-term neurologic improvement with significantly reduced frequencies of prolonged postoperative axial neck pain and loss of C2-7 angle after surgery.

  11. Needle versus Tube Thoracostomy in a Swine Model of Traumatic Tension Hemopneumothorax

    DTIC Science & Technology

    2009-03-01

    jugular vein, through the right atrium , and into the inferior vena cava . Serial digital C-arm chest x-rays allowed mea- surement of the shift from midline...wire in the inferior vena cava 1.34 cm to the right of the spinous processes. B: Insufflation resulted in a mediastinal shift of 2.15 cm to the left of...Received April 26, 2008, from the U.S. Army Institute of Surgical Re- search (JBH, JGM), Fort Sam Houston, Texas; the Naval Medical Cen- ter (STK), San Diego

  12. Development of a Novel Translational Model of Vibration Injury to the Spine to Study Acute Injury in Vivo

    DTIC Science & Technology

    2012-10-01

    were collected at 500 Hz. In addition, for the ST1 tests only, positional data were collected using the Optotrak at 200 Hz. Acceleration was measured...the accelerometer in order to characterize the skin-accelerometer system. Optotrak position data were measured during ST1 using markers on the spinous...particular, we have analyzed transmissibility at T3 and L4, corresponding to where the accelerometers were placed, and using the Optotrak data at

  13. Posterior spinal osteosynthesis for cervical fracture/dislocation using a flexible multistrand cable system: technical note.

    PubMed

    Huhn, S L; Wolf, A L; Ecklund, J

    1991-12-01

    Cervical instability secondary to fracture/dislocation or traumatic subluxation involving the posterior elements may be treated by a variety of fusion techniques. The rigidity of the stainless steel wires used in posterior cervical fusions often leads to difficulty with insertion, adequate tension, and conformation of the graft construct. This report describes a technique of posterior cervical fusion employing a wire system using flexible stainless steel cables. The wire consists of a flexible, 49-strand, stainless steel cable connected on one end to a short, malleable, blunt leader with the opposite end connected to a small islet. The cable may be used in occipitocervical, atlantoaxial, facet-to-spinous process, and interspinous fusion techniques. The cable loop is secured by using a tension/crimper device that sets the desired tension in the cable. In addition to superior biomechanical strength, the flexibility of the cable allows greater ease of insertion and tension adjustment. In terms of direct operative instrumentation in posterior cervical arthrodesis, involving both the upper and lower cervical spine, the cable system appears to be a safe and efficient alternative to monofilament wires.

  14. Cervical vertebral stenosis associated with a vertebral arch anomaly in the Basset Hound.

    PubMed

    De Decker, S; De Risio, L; Lowrie, M; Mauler, D; Beltran, E; Giedja, A; Kenny, P J; Gielen, I; Garosi, L; Volk, H

    2012-01-01

    To report the clinical presentation, imaging characteristics, treatment results, and histopathological findings of a previously undescribed vertebral malformation in the Basset Hound. Retrospective case series study. Eighteen Basset Hounds presented for evaluation of a suspected cervical spinal cord problem. All dogs underwent computed tomography myelography or magnetic resonance imaging of the cervical region. Thirteen male and 5 female Basset Hounds between 6 months and 10.8 years of age (median: 1.4 years) were studied. Clinical signs varied from cervical hyperesthesia to nonambulatory tetraparesis. Imaging demonstrated a well-defined and smooth hypertrophy of the dorsal lamina and spinous process of ≥ 2 adjacent vertebrae. Although this bony abnormality could decrease the ventrodorsal vertebral canal diameter, dorsal midline spinal cord compression was predominantly caused by ligamentum flavum hypertrophy. The articulation between C4 and C5 was most commonly affected. Three dogs were lost to follow-up, 10 dogs underwent dorsal laminectomy, and medical management was initiated in 5 dogs. Surgery resulted in a good outcome with short hospitalization times (median: 4.5 days) in all dogs, whereas medical management produced more variable results. Histopathology confirmed ligamentum flavum hypertrophy and demonstrated the fibrocartilaginous nature of this anomaly. Dorsal lamina and spinous process hypertrophy leading to ligamentum flavum hypertrophy should be included in the differential diagnosis of Basset Hounds with cervical hyperesthesia or myelopathy. Prognosis after decompressive surgery is favorable. Although a genetic component is suspected, additional studies are needed to determine the specific etiology of this disorder. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  15. Modified fenestration with restorative spinoplasty for lumbar spinal stenosis.

    PubMed

    Matsudaira, Ko; Yamazaki, Takashi; Seichi, Atsushi; Hoshi, Kazuto; Hara, Nobuhiro; Ogiwara, Satoshi; Terayama, Sei; Chikuda, Hirotaka; Takeshita, Katsushi; Nakamura, Kozo

    2009-06-01

    The authors developed an original procedure, modified fenestration with restorative spinoplasty (MFRS) for the treatment of lumbar spinal stenosis. The first step is to cut the spinous process in an L-shape, which is caudally reflected. This procedure allows easy access to the spinal canal, including lateral recesses, and makes it easy to perform a trumpet-style decompression of the nerve roots without violating the facet joints. After the decompression of neural tissues, the spinous process is anatomically restored (spinoplasty). The clinical outcomes at 2 years were evaluated using the Japanese Orthopaedic Association (JOA) scale and patients' satisfaction. Radiological follow-up included radiographs and CT. Between January 2000 and December 2002, 109 patients with neurogenic intermittent claudication with or without mild spondylolisthesis underwent MFRS. Of these, 101 were followed up for at least 2 years (follow-up rate 93%). The average score on the self-administered JOA scale in 89 patients without comorbidity causing gait disturbance improved from 13.3 preoperatively to 22.9 at 2 years' follow-up. Neurogenic intermittent claudication disappeared in all cases. The patients' assessment of treatment satisfaction was "satisfied" in 74 cases, "slightly satisfied" in 12, "slightly dissatisfied" in 2, and "dissatisfied" in 1 case. In 16 cases (18%), a minimum progression of slippage occurred, but no symptomatic instability or recurrent stenosis was observed. Computed tomography showed that the lateral part of the facet joints was well preserved, and the mean residual ratio was 80%. The MFRS technique produces an adequate and safe decompression of the spinal canal, even in patients with narrow and steep facet joints in whom conventional fenestration is technically demanding.

  16. Locating the Seventh Cervical Spinous Process: Accuracy of the Thorax-Rib Static Method and the Effects of Clinical Data on Its Performance.

    PubMed

    Ferreira, Ana Paula A; Póvoa, Luciana C; Zanier, José F C; Ferreira, Arthur S

    2017-02-01

    The aim of this study was to assess the thorax-rib static method (TRSM), a palpation method for locating the seventh cervical spinous process (C7SP), and to report clinical data on the accuracy of this method and that of the neck flexion-extension method (FEM), using radiography as the gold standard. A single-blinded, cross-sectional diagnostic accuracy study was conducted. One hundred and one participants from a primary-to-tertiary health care center (63 men, 56 ± 17 years of age) had their neck palpated using the FEM and the TRSM. A single examiner performed both the FEM and TRSM in a random sequence. Radiopaque markers were placed at each location with the aid of an ultraviolet lamp. Participants underwent chest radiography for assessment of the superimposed inner body structure, which was located by using either the FEM or the TRSM. Accuracy in identifying the C7SP was 18% and 33% (P = .013) with use of the FEM and the TRSM, respectively. The cumulative accuracy considering both caudal and cephalic directions (C7SP ± 1SP) increased to 58% and 81% (P = .001) with use of the FEM and the TRSM, respectively. Age had a significant effect on the accuracy of FEM (P = .027) but not on the accuracy of TRSM (P = .939). Sex, body mass, body height, and body mass index had no significant effects on the accuracy of both the FEM (P = .209 or higher) and the TRSM (P = .265 or higher). The TRMS located the C7SP more accurately compared with the FEM at any given level of anatomic detail, although both still underperformed in terms of acceptable accuracy for a clinical setting. Copyright © 2016. Published by Elsevier Inc.

  17. Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005.

    PubMed

    Wang, Jeremy C; Haid, Regis W; Miller, Jay S; Robinson, James C

    2006-02-01

    The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.

  18. Pediatric cervical spondylolysis and American football.

    PubMed

    Alton, Timothy B; Patel, Amit M; Lee, Michael J; Chapman, Jens R

    2014-06-01

    Cervical spondylolysis (CS) is a rare condition and is even more uncommon in pediatric patients. It is characterized by a disruption of the articular mass at the junction of the superior and inferior facet joints and often is diagnosed incidentally. The C6 level is most commonly involved, and the cause of CS remains unknown. There are no recommendations in the literature regarding activity modification in patients with CS and no discussion as to risks of participation in American football or other contact sports. To report a case of C6 bilateral cervical spondylolysis with bicuspid spinous process and to discuss radiographic/clinical findings and issues related to participation in contact sports and minimizing the risk of spinal cord injury. Case report with 6 months clinical/radiographic follow-up Radiographic description, clinical findings, and current review of the literature. A pediatric patient presented with a bilateral C6 cervical spondylolysis and bicuspid spinous process after an American football-related minor cervical spine trauma. Findings on radiographs indicated that the spondylolysis appeared to be chronic in nature, without evidence of instability. The patient and his family were educated on ways to decrease the risk of spinal cord injury with contact sports, after which the patient was allowed to participate fully in sports without restrictions or adverse events. Pediatric cervical spondylolysis is a rare condition, the cause of which remains debated. Although there is theoretical risk, more than 1.5 million youth participate in American football annually, and there have been no reported cases of significant spinal cord injury in patients with CS from football or other contact sports. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. [Regular pattern of pain reaction by pressing along the Governor Vessel on the back in patients with digestive system disease].

    PubMed

    Yang, Guang-Yin; Xu, Jin-Sen; Wu, Zu-Xing

    2012-02-01

    To find out the regular pattern of pain reaction by pressing along the Governor Vessel at the levels of T3 to L4 on the back in patients with digestive system disease, so as to provide references for diagnosis of the disease. Thirty patients diagnosed with digestive system disease by gastroscopy and colonoscopy as well as 16 patients with digestive symptoms without accurate diagnosis by endoscopy checks were observed. Pressing was applied from Zhiyang (GV 9) to Yaoyangguan (GV 3), including non-acupoints along the Governor Vessel. Positive reaction was recognized since pain, soreness or distension sensation appeared in the space between the spinous process. The positive ratios of 30 patients with endoscopy checks and 16 without the check accounted for 100.0%. The tender spots, usually 5 to 9 in number, were mainly focused on the relative acupoints and non-acupoints along the Governor Vessel from T6 to T10. The pain reaction from Lingtai (GV 10) to Zhongshu (GV 7), which are at the level of T6 to T10, along the Governor Vessel is closely related with digestive system disease. And it can be regarded as function criterion of the digestive system and important reference of auxiliary diagnosis.

  20. C/EBPα and C/EBPβ Are Required for Sebocyte Differentiation and Stratified Squamous Differentiation in Adult Mouse Skin

    PubMed Central

    House, John S.; Zhu, Songyun; Ranjan, Rakesh; Linder, Keith; Smart, Robert C.

    2010-01-01

    C/EBPα and C/EBPβ are bZIP transcription factors that are highly expressed in the interfollicular epidermis and sebaceous glands of skin and yet germ line deletion of either family member alone has only mild or no effect on keratinocyte biology and their role in sebocyte biology has never been examined. To address possible functional redundancies and reveal functional roles of C/EBPα and C/EBPβ in postnatal skin, mouse models were developed in which either family member could be acutely ablated alone or together in the epidermis and sebaceous glands of adult mice. Acute removal of either C/EBPα or C/EBPβ alone in adult mouse skin revealed modest to no discernable changes in epidermis or sebaceous glands. In contrast, co-ablation of C/EBPα and C/EBPβ in postnatal epidermis resulted in disruption of stratified squamous differentiation characterized by hyperproliferation of basal and suprabasal keratinocytes and a defective basal to spinous keratinocyte transition involving an expanded basal compartment and a diminished and delayed spinous compartment. Acute co-ablation of C/EBPα and C/EBPβ in sebaceous glands resulted in severe morphological defects, and sebocyte differentiation was blocked as determined by lack of sebum production and reduced expression of stearoyl-CoA desaturase (SCD3) and melanocortin 5 receptor (MC5R), two markers of terminal sebocyte differentiation. Specialized sebocytes of Meibomian glands and preputial glands were also affected. Our results indicate that in adult mouse skin, C/EBPα and C/EBPβ are critically involved in regulating sebocyte differentiation and epidermal homeostasis involving the basal to spinous keratinocyte transition and basal cell cycle withdrawal. PMID:20352127

  1. C/EBPalpha and C/EBPbeta are required for Sebocyte differentiation and stratified squamous differentiation in adult mouse skin.

    PubMed

    House, John S; Zhu, Songyun; Ranjan, Rakesh; Linder, Keith; Smart, Robert C

    2010-03-23

    C/EBPalpha and C/EBPbeta are bZIP transcription factors that are highly expressed in the interfollicular epidermis and sebaceous glands of skin and yet germ line deletion of either family member alone has only mild or no effect on keratinocyte biology and their role in sebocyte biology has never been examined. To address possible functional redundancies and reveal functional roles of C/EBPalpha and C/EBPbeta in postnatal skin, mouse models were developed in which either family member could be acutely ablated alone or together in the epidermis and sebaceous glands of adult mice. Acute removal of either C/EBPalpha or C/EBPbeta alone in adult mouse skin revealed modest to no discernable changes in epidermis or sebaceous glands. In contrast, co-ablation of C/EBPalpha and C/EBPbeta in postnatal epidermis resulted in disruption of stratified squamous differentiation characterized by hyperproliferation of basal and suprabasal keratinocytes and a defective basal to spinous keratinocyte transition involving an expanded basal compartment and a diminished and delayed spinous compartment. Acute co-ablation of C/EBPalpha and C/EBPbeta in sebaceous glands resulted in severe morphological defects, and sebocyte differentiation was blocked as determined by lack of sebum production and reduced expression of stearoyl-CoA desaturase (SCD3) and melanocortin 5 receptor (MC5R), two markers of terminal sebocyte differentiation. Specialized sebocytes of Meibomian glands and preputial glands were also affected. Our results indicate that in adult mouse skin, C/EBPalpha and C/EBPbeta are critically involved in regulating sebocyte differentiation and epidermal homeostasis involving the basal to spinous keratinocyte transition and basal cell cycle withdrawal.

  2. Determination of the human spine curve based on laser triangulation.

    PubMed

    Poredoš, Primož; Čelan, Dušan; Možina, Janez; Jezeršek, Matija

    2015-02-05

    The main objective of the present method was to automatically obtain a spatial curve of the thoracic and lumbar spine based on a 3D shape measurement of a human torso with developed scoliosis. Manual determination of the spine curve, which was based on palpation of the thoracic and lumbar spinous processes, was found to be an appropriate way to validate the method. Therefore a new, noninvasive, optical 3D method for human torso evaluation in medical practice is introduced. Twenty-four patients with confirmed clinical diagnosis of scoliosis were scanned using a specially developed 3D laser profilometer. The measuring principle of the system is based on laser triangulation with one-laser-plane illumination. The measurement took approximately 10 seconds at 700 mm of the longitudinal translation along the back. The single point measurement accuracy was 0.1 mm. Computer analysis of the measured surface returned two 3D curves. The first curve was determined by manual marking (manual curve), and the second was determined by detecting surface curvature extremes (automatic curve). The manual and automatic curve comparison was given as the root mean square deviation (RMSD) for each patient. The intra-operator study involved assessing 20 successive measurements of the same person, and the inter-operator study involved assessing measurements from 8 operators. The results obtained for the 24 patients showed that the typical RMSD between the manual and automatic curve was 5.0 mm in the frontal plane and 1.0 mm in the sagittal plane, which is a good result compared with palpatory accuracy (9.8 mm). The intra-operator repeatability of the presented method in the frontal and sagittal planes was 0.45 mm and 0.06 mm, respectively. The inter-operator repeatability assessment shows that that the presented method is invariant to the operator of the computer program with the presented method. The main novelty of the presented paper is the development of a new, non-contact method that provides a quick, precise and non-invasive way to determine the spatial spine curve for patients with developed scoliosis and the validation of the presented method using the palpation of the spinous processes, where no harmful ionizing radiation is present.

  3. Structural health monitoring to detect the presence, location and magnitude of structural damage in cadaveric porcine spines.

    PubMed

    Kawchuk, Gregory Neil; Decker, Colleen; Dolan, Ryan; Carey, Jason

    2009-01-19

    Structural health monitoring has been used successfully to identify defects in civil infrastructure and aerospace applications. Given that the majority of low back pain is thought to be mechanical in nature, our objective was to determine if structural health monitoring techniques could be employed successfully to identify the presence, location and magnitude of structural alterations within the spine. In six eviscerated cadaveric pigs, bone screws were drilled into the anterior bodies of L1-L5 and tri-axial accelerometers fixed to each spinous process. Vibration was then applied to the L3 spinous and frequency response functions obtained from each sensor axis before and after specific alterations of spinal structure. These alterations were produced at four unique locations and included (1) use of a cable tie to link anterior bone pins together and (2) progressive disc sectioning. Eighty percent of all data were used to train a neural network while the remaining data were used to test the network's ability to distinguish between structural states. The presence, location and magnitude of structural change within the spine was identified correctly in 5030/5040 possible neural network decisions. The diagnostic sensitivity and specificity of this technique ranged from 0.994 to 1.000. These results indicate that there is sufficient information embedded in frequency response data to identify the presence, location and magnitude of specific structural changes in the spine. If these techniques can be evolved for human use, structural health monitoring may provide a new approach toward understanding the underlying relations between spinal structure and function.

  4. Differential synaptic plasticity of the corticostriatal and thalamostriatal systems in an MPTP-treated monkey model of parkinsonism.

    PubMed

    Raju, Dinesh V; Ahern, Todd H; Shah, Deep J; Wright, Terrence M; Standaert, David G; Hall, Randy A; Smith, Yoland

    2008-04-01

    Two cardinal features of Parkinson's disease (PD) pathophysiology are a loss of glutamatergic synapses paradoxically accompanied by an increased glutamatergic transmission to the striatum. The exact substrate of this increased glutamatergic drive remains unclear. The striatum receives glutamatergic inputs from the thalamus and the cerebral cortex. Using vesicular glutamate transporters (vGluTs) 1 and 2 as markers of the corticostriatal and thalamostriatal afferents, respectively, we examined changes in the synaptology and relative prevalence of striatal glutamatergic inputs in methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP)-treated monkeys using electron microscopic immunoperoxidase and confocal immunofluorescence methods. Our findings demonstrate that the prevalence of vGluT1-containing terminals is significantly increased in the striatum of MPTP-treated monkeys (51.9 +/- 3.5% to 66.5 +/- 3.4% total glutamatergic boutons), without any significant change in the pattern of synaptic connectivity; more than 95% of vGluT1-immunolabeled terminals formed axo-spinous synapses in both conditions. In contrast, the prevalence of vGluT2-immunoreactive terminals did not change after MPTP treatment (21.7 +/- 1.3% vs. 21.6 +/- 1.2% total glutamatergic boutons). However, a substantial increase in the ratio of axo-spinous to axo-dendritic synapses formed by vGluT2-immunoreactive terminals was found in the pre-caudate and post-putamen striatal regions of MPTP-treated monkeys, suggesting a certain degree of synaptic reorganization of the thalamostriatal system in parkinsonism. About 20% of putative glutamatergic terminals did not show immunoreactivity in striatal tissue immunostained for both vGluT1 and vGluT2, suggesting the expression of another vGluT in these boutons. These findings provide striking evidence that suggests a differential degree of plasticity of the corticostriatal and thalamostriatal system in PD.

  5. Immediate effects on electromyographic activity and pressure pain thresholds after a cervical manipulation in mechanical neck pain: a randomized controlled trial.

    PubMed

    de Camargo, Viviane Maduro; Alburquerque-Sendín, Francisco; Bérzin, Fausto; Stefanelli, Vinicius Cobos; de Souza, Daiana P Rodrigues; Fernández-de-las-Peñas, César

    2011-05-01

    The purpose of this study was to identify the immediate effects of a manipulation of C5/C6 level on electromyography (EMG) of the deltoid muscle and in pressure pain thresholds (PPTs) in patients with mechanical neck pain. Thirty-seven subjects with mechanical neck pain were randomly divided into 2 groups: manipulative group, which received a cervical spine manipulation targeted to C5/C6 segment, and a control group, which did not receive any procedure. Outcomes were EMG data of the deltoid muscle (rest, isometric contraction for 5 or 30 seconds, and isotonic contraction) and PPT over upper trapezius and deltoid muscles and C5 spinous process. They were assessed before and 5 minutes after treatment by a blinded assessor. A 3-way repeated-measures analysis of variance was used to examine the effects of the manipulation. A significant group time interaction for MF at the beginning of isometric contraction for 30 seconds (F = 7.957, P = .006) was also found: the manipulative group experienced a greater increase in MF at the beginning of the isometric contraction than did the control group. A significant group time interaction was also found for root mean square during isometric contraction for 30 seconds (P = .003); however, changes were small. Patients within the manipulative group experienced an increase on PPT over the deltoid (P = .010) and C5 spinous process (P = .025), but not over upper trapezius (P = .776). Manipulation at C5/C6 level in the study participants seemed to increase EMG amplitude signal and fatigue resistance in a nonspinal (deltoid) muscle innervated by the same segment in patients with mechanical neck pain. However, these changes were relative small. An increase on PPT over those tissues innervated by the manipulated segment was also found after the manipulative procedure. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  6. Locating the Seventh Cervical Spinous Process: Development and Validation of a Multivariate Model Using Palpation and Personal Information.

    PubMed

    Ferreira, Ana Paula A; Póvoa, Luciana C; Zanier, José F C; Ferreira, Arthur S

    2017-02-01

    The aim of this study was to develop and validate a multivariate prediction model, guided by palpation and personal information, for locating the seventh cervical spinous process (C7SP). A single-blinded, cross-sectional study at a primary to tertiary health care center was conducted for model development and temporal validation. One-hundred sixty participants were prospectively included for model development (n = 80) and time-split validation stages (n = 80). The C7SP was located using the thorax-rib static method (TRSM). Participants underwent chest radiography for assessment of the inner body structure located with TRSM and using radio-opaque markers placed over the skin. Age, sex, height, body mass, body mass index, and vertex-marker distance (D V-M ) were used to predict the distance from the C7SP to the vertex (D V-C7 ). Multivariate linear regression modeling, limits of agreement plot, histogram of residues, receiver operating characteristic curves, and confusion tables were analyzed. The multivariate linear prediction model for D V-C7 (in centimeters) was D V-C7 = 0.986D V-M + 0.018(mass) + 0.014(age) - 1.008. Receiver operating characteristic curves had better discrimination of D V-C7 (area under the curve = 0.661; 95% confidence interval = 0.541-0.782; P = .015) than D V-M (area under the curve = 0.480; 95% confidence interval = 0.345-0.614; P = .761), with respective cutoff points at 23.40 cm (sensitivity = 41%, specificity = 63%) and 24.75 cm (sensitivity = 69%, specificity = 52%). The C7SP was correctly located more often when using predicted D V-C7 in the validation sample than when using the TRSM in the development sample: n = 53 (66%) vs n = 32 (40%), P < .001. Better accuracy was obtained when locating the C7SP by use of a multivariate model that incorporates palpation and personal information. Copyright © 2016. Published by Elsevier Inc.

  7. Cell proliferation and p53 expression in pseudoepitheliomatous hyperplasia of oral paracoccidioidomycosis.

    PubMed

    Kaminagakura, E; Bonan, P R F; Lopes, M A; Almeida, O P

    2006-09-01

    Paracoccidioidomycosis (PCMycosis) is a systemic mycosis frequently found in many regions of Latin America. Microscopically, it is characterised by granulomatous inflammation and pseudoepitheliomatous hyperplasia (PEH). This work describes the proliferation index and p53 expression by immunohistochemistry in PEH of PCMycosis, normal oral mucosa (NOM) and mild oral epithelial dysplasia (ED). Ki67 positive cells were present in the basal and parabasal layers in NOM and PEH, while in ED it was also observed in the spinous layer. Percentage of ki67 positive cells was 7.7, 28.2 and 46.0 in NOM, PEH and ED respectively. p53 was negative in NOM and in PEH it was expressed by few cells in the basal layer of only three cases. However, it was expressed in all cases of ED, in basal and parabasal layers. Although histologically PEH mimics well-differentiated squamous cell carcinoma, its proliferative pattern and p53 expression are more similar to NOM than to dysplasia. These findings, confirm PEH as a reactive process probably associated with the underlying chronic inflammation.

  8. A new species of Echinolaophonte and record of E. armiger (Gurney, 1927) (Crustacea, Copepoda, Harpacticoida, Laophontidae) from the Caribbean with a key to species

    PubMed Central

    Fuentes-Reinés, Juan Manuel; Suárez-Morales, Eduardo

    2017-01-01

    Abstract A new species of the harpacticoid copepod genus Echinolaophonte is described here from specimens obtained during a biological survey of Rodadero Bay, a coastal system in the Colombian Caribbean. This species has been previously recorded as E. armiger Gurney, 1927 in different geographic areas (Indian and Pacific Oceans). The Colombian specimens recognized as E. villabonae sp. n. and true E. armiger are deemed as distinct species based on differences in several features of which the shape of the rostrum and the dorsal spinous process on the prosome are among the most distinctive. These and other characters are shared by specimens recorded as E. armiger from Caroline Islands and Australia that are now incorporated to the new species. The finding of the true E. armiger, previously known only from Egypt, the Texan coast, Brazil, and possibly Bermuda, constitutes the first record of this species in the western Caribbean and a regional range extension. A key to the identification of the 13 known species of the genus is also provided. PMID:29308028

  9. A new species of Echinolaophonte and record of E. armiger (Gurney, 1927) (Crustacea, Copepoda, Harpacticoida, Laophontidae) from the Caribbean with a key to species.

    PubMed

    Fuentes-Reinés, Juan Manuel; Suárez-Morales, Eduardo

    2017-01-01

    A new species of the harpacticoid copepod genus Echinolaophonte is described here from specimens obtained during a biological survey of Rodadero Bay, a coastal system in the Colombian Caribbean. This species has been previously recorded as E. armiger Gurney, 1927 in different geographic areas (Indian and Pacific Oceans). The Colombian specimens recognized as E. villabonae sp. n. and true E. armiger are deemed as distinct species based on differences in several features of which the shape of the rostrum and the dorsal spinous process on the prosome are among the most distinctive. These and other characters are shared by specimens recorded as E. armiger from Caroline Islands and Australia that are now incorporated to the new species. The finding of the true E. armiger , previously known only from Egypt, the Texan coast, Brazil, and possibly Bermuda, constitutes the first record of this species in the western Caribbean and a regional range extension. A key to the identification of the 13 known species of the genus is also provided.

  10. C7 vertebra homeotic transformation in domestic dogs - are Pug dogs breaking mammalian evolutionary constraints?

    PubMed

    Brocal, J; De Decker, S; José-López, R; Manzanilla, E G; Penderis, J; Stalin, C; Bertram, S; Schoenebeck, J J; Rusbridge, C; Fitzpatrick, N; Gutierrez-Quintana, R

    2018-05-14

    The number of cervical vertebrae in mammals is almost constant at seven, regardless of their neck length, implying that there is selection against variation in this number. Homebox (Hox) genes are involved in this evolutionary mammalian conservation, and homeotic transformation of cervical into thoracic vertebrae (cervical ribs) is a common phenotypic abnormality when Hox gene expression is altered. This relatively benign phenotypic change can be associated with fatal traits in humans. Mutations in genes upstream of Hox, inbreeding and stressors during organogenesis can also cause cervical ribs. The aim of this study was to describe the prevalence of cervical ribs in a large group of domestic dogs of different breeds, and explore a possible relation with other congenital vertebral malformations (CVMs) in the breed with the highest prevalence of cervical ribs. By phenotyping we hoped to give clues as to the underlying genetic causes. Twenty computed tomography studies from at least two breeds belonging to each of the nine groups recognized by the Federation Cynologique Internationale, including all the brachycephalic 'screw-tailed' breeds that are known to be overrepresented for CVMs, were reviewed. The Pug dog was more affected by cervical ribs than any other breed (46%; P < 0.001), and was selected for further analysis. No association was found between the presence of cervical ribs and vertebral body formation defect, bifid spinous process, caudal articular process hypoplasia/aplasia and an abnormal sacrum, which may infer they have a different aetiopathogenesis. However, Pug dogs with cervical ribs were more likely to have a transitional thoraco-lumbar vertebra (P = 0.041) and a pre-sacral vertebral count of 26 (P < 0.001). Higher C7/T1 dorsal spinous processes ratios were associated with the presence of cervical ribs (P < 0.001), supporting this is a true homeotic transformation. Relaxation of the stabilizing selection has likely occurred, and the Pug dog appears to be a good naturally occurring model to further investigate the aetiology of cervical ribs, other congenital vertebral anomalies and numerical alterations. © 2018 Anatomical Society.

  11. Analysis Of Scoliosis By Back Shape Topography

    NASA Astrophysics Data System (ADS)

    Turner-Smith, Alan R.; Harris, John D.

    1983-07-01

    The use of surface topography for the assessment of scoliotic deformity in the clinic depends firstly on the quality of measures which reliably characterise deformity of the back, and secondly on the ease and speed with which these measures can be applied. A method of analysis of back shape measurements is presented which can be applied to any topographic measurement system. Measures presented are substantially independent of minor changes in the patient's posture in rotation and flexion from one clinic to the next, and yet sensitive enough to indicate significant improvement or degeneration of the disease. The presentation shows (1) horizontal cross-sections at ten levels up the back from sacrum to vertebra prominens, (2) angles of rotation of the surface over a small region about the spine, (3) three vertical profiles following the line of the spine, and (4) measures of maximum kyphosis and lordosis. Dependence on the operator has been reduced to a minimum. Extreme care in positioning the patient is unnecessary and those spinous processes which are easily palpable, the vertebra prominens and the two dimples over the posterior superior iliac spines are marked. Analysis proceeds entirely automatically once the basic shape data have been supplied. Applications of the technique to indirect moire topography and a television topographic measurement system are described.

  12. A new species of the genus Amyrsidea (Phthiraptera: Amblycera: Menoponidae) parasitizing domestic chickens in Saudi Arabia.

    PubMed

    Alahmed, Azzam; Aldryhim, Yousif; Shobrak, Mohammed; Nasser, Mohamed

    2017-03-02

    Amyrsidea Ewing, 1927 is a genus of chewing lice comprising 52 species, divided into five subgenera: Amyrsidea sensu stricto, Argimenopon Eichler, 1947, Cracimenopon Carriker, 1954, Desumenopon Carriker, 1954 and Numidimenopon Scharf & Price, 1977 (see Price et al. 2003: 86), which parasitise a wide range of hosts belonging to the avian order Galliformes (see Price et al. 2003: 321). Species of Amyrsidea can be distinguished from species of Menacanthus Neumann, 1912-the other menoponid genus with species parasitic on the same hosts-by lacking ventral spinous processes in the head (Scharf & Price 1977: 815). Revisions of all subgenera and species of Amyrsidea, including keys for their identification, were published by Scharf & Price (1977, 1983) and Scharf & Emerson (1983, 1984).

  13. Thoracolumbar Junction Syndrome Causing Pain around Posterior Iliac Crest: A Case Report.

    PubMed

    Kim, Soo-Ryu; Lee, Min-Ji; Lee, Seung-Jun; Suh, Young-Sung; Kim, Dae-Hyun; Hong, Ji-Hee

    2013-03-01

    Thoracolumbar junction syndrome is characterized by referred pain which may originate at the thoracolumbar junction, which extends from 12th thoracic vertebra to 2nd lumbar vertebra, due to functional abnormalities. Clinical manifestations include back pain, pseudo-visceral pain and pseudo-pain on the posterior iliac crest, as well as irritable bowel symptoms. During clinical examination, pain can be demonstrated by applying pressure on the facet joints or to the sides of the spinous processes. Radiological studies show only mild and insignificant degenerative changes in most cases. We report a 42-year-old female patient with osteogenesis imperfecta who suffered from chronic low back pain. Under the diagnosis of thoracolumbar junction syndrome, she was treated with an epidural block and a sympathetic nerve block, which improved her symptoms.

  14. Structural health monitoring (vibration) as a tool for identifying structural alterations of the lumbar spine: a twin control study.

    PubMed

    Kawchuk, Gregory N; Hartvigsen, Jan; Edgecombe, Tiffany; Prasad, Narasimha; van Dieen, Jaap H

    2016-03-11

    Structural health monitoring (SHM) is an engineering technique used to identify mechanical abnormalities not readily apparent through other means. Recently, SHM has been adapted for use in biological systems, but its invasive nature limits its clinical application. As such, the purpose of this project was to determine if a non-invasive form of SHM could identify structural alterations in the spines of living human subjects. Lumbar spines of 10 twin pairs were visualized by magnetic resonance imaging then assessed by a blinded radiologist to determine whether twin pairs were structurally concordant or discordant. Vibration was then applied to each subject's spine and the resulting response recorded from sensors overlying lumbar spinous processes. The peak frequency, area under the curve and the root mean square were computed from the frequency response function of each sensor. Statistical analysis demonstrated that in twins whose structural appearance was discordant, peak frequency was significantly different between twin pairs while in concordant twins, no outcomes were significantly different. From these results, we conclude that structural changes within the spine can alter its vibration response. As such, further investigation of SHM to identify spinal abnormalities in larger human populations is warranted.

  15. Lumbar spinous process splitting decompression provides equivalent outcomes to conventional midline decompression in degenerative lumbar canal stenosis: a prospective, randomized controlled study of 51 patients.

    PubMed

    Rajasekaran, S; Thomas, Ashok; Kanna, Rishi M; Prasad Shetty, Ajoy

    2013-09-15

    Prospective, randomized controlled study. To compare the functional outcomes and extent of paraspinal muscle damage between 2 decompressive techniques for lumbar canal stenosis. Lumbar spinous process splitting decompression (LSPSD) preserves the muscular and liga-mentous attachments of the posterior elements of the spine. It can potentially avoid problems such as paraspinal muscle atrophy and trunk extensor weakness that can occur after conventional midline decompression. However, large series prospective randomized controlled studies are lacking. Patients with lumbar canal stenosis were randomly allocated into 2 groups: LSPSD (28 patients) and conventional midline decompression (23 patients). The differences in operative time, blood loss, time to comfortable mobilization, and hospital stay were studied. Paraspinal muscle damage was assessed by postoperative rise in creatine phosphokinase and C-reactive protein levels. Functional outcome was evaluated at 1 year by Japanese Orthopaedic Association score, neurogenic claudication outcome score, and visual analogue scale for back pain and neurogenic claudication. Fifty-one patients of mean age 56 years were followed-up for a mean 14.2 ± 2.9 months. There were no significant differences in the operative time, blood loss, and hospital stay. Both the groups showed significant improvement in the functional outcome scores at 1 year. Between the 2 groups, the Japanese Orthopaedic Association score, neurogenic claudication outcome score improvement, visual analogue scale for back pain, neurogenic claudication visual analogue scale, and the postoperative changes in serum C-reactive protein and creatine phosphokinase levels did not show any statistically significant difference. On the basis of the Japanese Orthopaedic Association recovery rate, it was found that 73.9% of conventional midline decompression group had good outcomes compared with only 60.7% after LSPSD. The functional outcome scores, back pain, and claudication pain in the immediate period and at the end of 1 year are similar in both the techniques. More patients had better functional outcomes after conventional decompression than the LSPSD technique. On the basis of this study, the superiority of one technique compared with the other is not established, mandating the need for further long-term studies. 2.

  16. Quantification of Bone Marrow Edema by Magnetic Resonance Imaging Only Marginally Reflects Clinical Neck Pain Evaluation in Rheumatoid Arthritis and Ankylosing Spondylitis.

    PubMed

    Baraliakos, Xenofon; Heldmann, Frank; Callhoff, Johanna; Suppiah, Ravi; McQueen, Fiona Marion; Krause, Dietmar; Klink, Claudia; Schmitz-Bortz, Elmar; Igelmann, Manfred; Kalthoff, Ludwig; Kiltz, Uta; Schmuedderich, Anna; Braun, Juergen

    2016-12-01

    Neck pain is common in rheumatoid arthritis (RA) and ankylosing spondylitis (AS). We investigated the correlation of bone marrow edema (BME) on magnetic resonance imaging (MRI) in RA and AS and its association with clinical complaints of neck pain. Cervical spine short-tau inversion recovery-MRI and T1w-MRI of 34 patients with RA and 6 patients with AS complaining about neck pain were obtained. Clinical and laboratory data were available. BME was scored by 2 blinded readers using a modification of a published score, including various cervical sites. Degenerative changes were also quantified. Patients were predominantly women (82.5%), and mean ± SD age was 57.5 ± 11.8 years, C-reactive protein (CRP) was 0.8 ± 1.3 mg/dl, and pain score was 46.0 ± 17.5. BME was detected in 24/40 patients (60%) involving the atlantoaxial region (21%), vertebral bodies (75%), facet joints (29%), and spinous processes (46%). Degenerative changes were identified in 21/40 patients (52.5%), 13 (62%) of whom also had BME in vertebral bodies. No differences were found between patients with versus without cervical BME for clinical assessments: numeric rating scale pain (median ± interquartile range) 5.5 ± 3.0 vs 6.0 ± 4.0 (p = 0.69), Funktionsfragebogen Hannover 68.2 ± 41.0 vs 42.0 ± 55.5 (p = 0.19), Northwick pain score 44.4 ± 21.8 vs 47.2 ± 27.0 (p = 0.83), or CRP 0.40 ± 0.80 vs 0.60 ± 0.66 (p = 0.94). For patients with degenerative changes, symptom duration was longer than for patients without (10 ± 12.5 vs 5.0 ± 18.0 yrs, p = 0.73). In this small study of patients with RA and AS complaining about neck pain, BME was found in many different cervical sites, including the facet joints and the spinous processes. However, the occurrence and severity of BME did not correlate with the severity of neck pain.

  17. Migrating lumbar facet joint cysts.

    PubMed

    Palmieri, Francesco; Cassar-Pullicino, Victor N; Lalam, Radhesh K; Tins, Bernhard J; Tyrrell, Prudencia N M; McCall, Iain W

    2006-04-01

    The majority of lumbar facet joint cysts (LFJCs) are located in the spinal canal, on the medial aspect of the facet joint with characteristic diagnostic features. When they migrate away from the joint of origin, they cause diagnostic problems. In a 7-year period we examined by computed tomography (CT) and magnetic resonance (MR) imaging five unusual cases of facet joint cysts which migrated from the facet joint of origin. Three LFJCs were identified in the right S1 foramen, one in the right L5-S1 neural foramen and one in the left erector spinae and multifidus muscles between the levels of L2-L4 spinous process. Awareness that spinal lesions identified at MRI and CT could be due to migrating facet joint cyst requires a high level of suspicion. The identification of the appositional contact of the cyst and the facet joint needs to be actively sought in the presence of degenerative facet joints.

  18. The Neandertal vertebral column 1: the cervical spine.

    PubMed

    Gómez-Olivencia, Asier; Been, Ella; Arsuaga, Juan Luis; Stock, Jay T

    2013-06-01

    This paper provides a metric analysis of the Neandertal cervical spine in relation to modern human variation. All seven cervical vertebrae have been analysed. Metric data from eight Neandertal individuals are compared with a large sample of modern humans. The significance of morphometric differences is tested using both z-scores and two-tailed Wilcoxon signed rank tests. The results identify significant metric and morphological differences between Neandertals and modern humans in all seven cervical vertebrae. Neandertal vertebrae are mediolaterally wider and dorsoventrally longer than modern humans, due in part to longer and more horizontally oriented spinous processes. This suggests that Neandertal cervical morphology was more stable in both mid-sagittal and coronal planes. It is hypothesized that the differences in cranial size and shape in the Neandertal and modern human lineages from their Middle Pleistocene ancestors could account for some of the differences in the neck anatomy between these species. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Learning from eponyms: George F. Odland and Odland bodies

    PubMed Central

    Joshi, Rajiv

    2014-01-01

    Odland bodies (lamellar) bodies are small sub-cellular structures of size 200-300 nm that are present in the upper spinous and granular cell layers of the epidermis. These act as processing and repository areas for lipids that contribute to the epidermal permeability barrier. They also contain proteases, cathepsin D, kallikrein and other proteins including corneo-desmosins. Recent information also credits them with a role in the local innate immune response as they contain beta 2 defensins, which are anti-microbial peptides with potent activity against Gram-negative bacteria and candida. Odland bodies are important for maintaining homeostasis of the epidermis and are involved in epidermal permeability barrier function, desquamation of keratinocytes, formation of the cornified envelope and in local anti-microbial immunity. This article reviews the structure and functions of these bodies with a brief biography of George F. Odland who first described these bodies in 1960 and whose name is eponymically associated with them. PMID:25165659

  20. Temporal variation of dielectric properties of preserved blood.

    PubMed

    Hayashi, Yoshihito; Oshige, Ikuya; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji

    2008-01-07

    Rabbit blood was preserved at 277 K in Alsever's solution for 37 days, and its dielectric permittivity was monitored in a frequency range from 0.05 to 110 MHz throughout the period. The relaxation time and Cole-Cole parameter of the interfacial polarization process for erythrocytes remained nearly constant during the first 20 days and then started to increase and decrease, respectively. On the other hand, the relaxation strength and the cell volume fraction continued to decrease for 37 days, but the decrease rates of both changed discontinuously on about the 20th day. Microscope observation showed that approximately 90% of the erythrocytes were spinous echinocytes at the beginning of preservation and started to be transformed into microspherocytes around the 20th day. Therefore, dielectric spectroscopy is a sensitive tool to monitor the deterioration of preserved blood accompanied by morphological transition of erythrocytes through the temporal variation of their dielectric properties.

  1. Experimental oral lead toxicity in young dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stowe, H.D.; Goyer, R.A.; Krigman, M.M.

    1973-02-01

    Litter-mate male pups were fed a calcium-and-phosphorus-low purified diet with and without 100 ppm of lead as lead acetate from age 6 to 18 weeks. Lead-toxic dogs exhibited cyclic but terminally severe anorexia and cachexia, significant anemia, normoblastocytosis and leukopenia within six weeks, hypoproteinemia, decreased serum albumin, ..cap alpha../sub 1/-globulin, ..beta../sub 2/-globulin, alkaline phosphatase and lactic dehydrogenase 1, elevated serum glutamic oxaloacetic and pyruvic transaminases, delayed closure of the thoracic vertebral epiphyses, lead lines in the distal radii and thoracic spinous processes, enlargement of liver, kidney, and brain, hepatic fatty metamorphosis, focal proximal renal tubular necrosis, hydropic degeneration of spermatognia,more » and lead inclusion body formation. Approximately 97% of the tissue lead was estimated to be skeletal; the greatest concentration of lead in the brain was found in the occipital gray matter.« less

  2. Increased matriptase zymogen activation in inflammatory skin disorders

    PubMed Central

    Chen, Cheng-Jueng; Wu, Bai-Yao; Tsao, Pai-In; Chen, Chi-Yung; Wu, Mei-Hsuan; Chan, Yee Lam E.; Lee, Herng-Sheng; Johnson, Michael D.; Eckert, Richard L.; Chen, Ya-Wen; Chou, Fengpai; Lin, Chen-Yong

    2011-01-01

    Matriptase, a type 2 transmembrane serine protease, and its inhibitor hepatocyte growth factor activator inhibitor (HAI)-1 are required for normal epidermal barrier function, and matriptase activity is tightly regulated during this process. We therefore hypothesized that this protease system might be deregulated in skin disease. To test this, we examined the level and activation state of matriptase in examples of 23 human skin disorders. We first examined matriptase and HAI-1 protein distribution in normal epidermis. Matriptase was detected at high levels at cell-cell junctions in the basal layer and spinous layers but was present at minimal levels in the granular layer. HAI-1 was distributed in a similar pattern, except that high-level expression was retained in the granular layer. This pattern of expression was retained in most skin disorders. We next examined the distribution of activated matriptase. Although activated matriptase is not detected in normal epidermis, a dramatic increase is seen in keratinocytes at the site of inflammation in 16 different skin diseases. To gain further evidence that activation is associated with inflammatory stimuli, we challenged HaCaT cells with acidic pH or H2O2 and observed matriptase activation. These findings suggest that inflammation-associated reactive oxygen species and tissue acidity may enhance matriptase activation in some skin diseases. PMID:21123732

  3. Inhomogeneous Monte Carlo simulations of dermoscopic spectroscopy

    NASA Astrophysics Data System (ADS)

    Gareau, Daniel S.; Li, Ting; Jacques, Steven; Krueger, James

    2012-03-01

    Clinical skin-lesion diagnosis uses dermoscopy: 10X epiluminescence microscopy. Skin appearance ranges from black to white with shades of blue, red, gray and orange. Color is an important diagnostic criteria for diseases including melanoma. Melanin and blood content and distribution impact the diffuse spectral remittance (300-1000nm). Skin layers: immersion medium, stratum corneum, spinous epidermis, basal epidermis and dermis as well as laterally asymmetric features (eg. melanocytic invasion) were modeled in an inhomogeneous Monte Carlo model.

  4. [A lymphoepithelioma-like type of spinous-cell carcinoma of the cervix uteri].

    PubMed

    Pires, M A; Andrade, M J; Guerra, C; Silva, T S; de Oliveira, C; Beja, M

    1999-01-01

    Lymphoepithelioma-like carcinomas of the cervix uteri are very rare. They are poorly differentiated squamous cell carcinomas with intense stromal lymphocytic infiltration. These histologic features are similar to nasopharyngeal lymphoepithelioma and may have a better prognosis than other tumors of the cervix. A lymphoepithelioma-like lesion of the cervix uteri is described in a 33-year-old Caucasian woman who had an episode of vaginal bleeding. A review of the literature about these types of tumor is also presented.

  5. Flexible superior electrode architectures based on three-dimensional porous spinous α-Fe2O3 with a high performance as a supercapacitor.

    PubMed

    Nan, Honghong; Yu, Liutao; Ma, Wenqin; Geng, Baoyou; Zhang, Xiaojun

    2015-05-28

    Flexible supercapacitors have recently attracted increasing attention as they show unique promising advantages, such as flexibility and shape diversity, and they are light-weight and so on. Herein, we designed a series of 3D porous spinous iron oxide materials synthesized on a thin iron plate through a facile method under mild conditions. The unique nanostructural features endow them with excellent electrochemical performance. The electrochemical properties of the integrated electrodes as active electrode materials for supercapacitors have been investigated using different electrochemical techniques including cyclic voltammetry, and galvanostatic charge-discharge in Na2SO4 and LiPF6/EC : DEC electrolyte solutions. These integrated electrodes showed high specific capacitance (as high as 524.6 F g(-1) at the current density of 1 A g(-1)) in 1.0 M Na2SO4 (see Table S1). Moreover, the integrated electrodes also show high power densities and high energy densities in a LiPF6/EC : DEC electrolyte solution; for example, the energy densities were 319.3, 252.5, 152.1, 74.13 and 38.6 W h kg(-1) at different power densities of 8.81, 21.59, 56.65, 92.09 and 152.64 kW kg(-1), respectively. Additionally, the flexible superior electrode exhibited excellent stability with capacitance retention of 92.9% after 5000 cycles. Therefore, such flexible integrated devices might be used in smart and portable electronics.

  6. Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion.

    PubMed

    Bedekar, Nilima; Suryawanshi, Mayuri; Rairikar, Savita; Sancheti, Parag; Shyam, Ashok

    2014-01-01

    Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.

  7. Imaging of human vertebral surface using ultrasound RF data received at each element of probe for thoracic anesthesia

    NASA Astrophysics Data System (ADS)

    Takahashi, Kazuki; Taki, Hirofumi; Onishi, Eiko; Yamauchi, Masanori; Kanai, Hiroshi

    2017-07-01

    Epidural anesthesia is a common technique for perioperative analgesia and chronic pain treatment. Since ultrasonography is insufficient for depicting the human vertebral surface, most examiners apply epidural puncture by body surface landmarks on the back such as the spinous process and scapulae without any imaging, including ultrasonography. The puncture route to the epidural space at thoracic vertebrae is much narrower than that at lumber vertebrae, and therefore, epidural anesthesia at thoracic vertebrae is difficult, especially for a beginner. Herein, a novel imaging method is proposed based on a bi-static imaging technique by making use of the transmit beam width and direction. In an in vivo experimental study on human thoracic vertebrae, the proposed method succeeded in depicting the vertebral surface clearly as compared with conventional B-mode imaging and the conventional envelope method. This indicates the potential of the proposed method in visualizing the vertebral surface for the proper and safe execution of epidural anesthesia.

  8. Preferred view and transducer in lumbar ultrasound in overweight and obese patients.

    PubMed

    Farahmand, Shervin; Safavi, Somayeh; Shahriarian, Shahriar; Arbab, Mona; Basirghafoori, Hamed; Bagheri-Hariri, Shahram

    2017-02-01

    Ultrasound can be used to facilitate lumbar puncture, especially in obese patients. In this study, midline and paramedian approaches with curved and linear transducers were compared in patients with Body Mass Index (BMI) above 25 kg/m 2 for the identification of spinal landmarks. In each view, six major landmarks, including spinous process, ligamentum flavum, laminae, epidural space, subarachnoid space and posterior longitudinal ligament, were detected by emergency medicine residents and were then reviewed by radiologists. Sixty patients with a mean BMI of 29.18 enrolled in the study. This study showed that a curved transducer detected major landmarks more accurately compared to a linear transducer. There was also a poor kappa correlation between these transducers in the midline and paramedian approaches. This study showed that ultrasound can detect lumbar landmarks in overweight and obese patients, with the paramedian approach and a curved transducer being superior to the midline approach and a linear transducer in detecting these landmarks.

  9. The Clay Shoveler's Fracture: A Case Report and Review of the Literature.

    PubMed

    Posthuma de Boer, Jantine; van Wulfften Palthe, Alexander F Y; Stadhouder, Agnita; Bloemers, Frank W

    2016-09-01

    A clay-shoveler's fracture is a very rarely occurring stress-type avulsion fracture of the lower cervical or upper thoracic spinous processes owing its name to the clay shovelers of past times. Currently, this type of injury is mainly encountered in individuals practicing sports involving rotational movements of the upper spine. We present a case of a man sustaining a clay-shoveler's injury during his work in a horse-riding school. Treatment consisted of a period of rest and analgesics, followed by mobilization as was tolerated. We give a brief historical account of clay shoveler's fractures. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Clay-shoveler's fractures are frequently overlooked due to their rareness; however, they have specific clinical features that should alert an attending physician to set the correct diagnosis. This report describes a typical case of a clay-shoveler's fracture, relates to the historical entity of clay-shoveler's fractures, and summarizes existing literature on this topic. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Effects of Epidermal Growth Factor-Loaded Mucoadhesive Films on Wounded Oral Tissue Rafts

    PubMed Central

    Ramineni, Sandeep K.; Fowler, Craig B.; Fisher, Paul D.; Cunningham, Larry L.; Puleo, David A.

    2015-01-01

    Current treatments for traumatic oral mucosal wounds include the gold standard of autologous tissue and alternative tissue engineered grafts. While use of autografts has disadvantages of minimal availability of oral keratinized tissue, second surgery, and donor site discomfort, tissue engineered grafts are limited by their unavailability as off-the-shelf products owing to their fabrication time of 4–8 weeks. Hence, the current work aimed to develop a potentially cost-effective, readily available device capable of enhancing native mucosal regeneration. Considering the key role of epidermal growth factor (EGF) in promoting mucosal wound regeneration and the advantages of mucoadhesive delivery systems, mucoadhesive films composed of polyvinylpyrrolidone and carboxymethylcellulose were developed to provide sustained release of EGF for minimum of 6 hours. Bioactivity of released EGF supernatants was then confirmed by its ability to promote proliferation of BALB/3T3 fibroblasts. Efficacy of the developed system was then investigated in vitro using buccal tissues (ORL 300-FT) as a potential replacement for small animal studies. Although the mucoadhesive films achieved their desired role of delivering bioactive EGF in a sustained manner, treatment with EGF, irrespective of its release from the films or solubilized in medium, caused a hyperparakeratotic response from in vitro tissues with distinguishable histological features including thickening of the spinous layer, intra- and intercellular edema, and pyknotic nuclei. These significant morphological changes were associated with no improvements in wound closure. These observations raise questions about the potential of using in vitro tissues as a wound healing model and substitute for small animal studies. The mucoadhesive delivery system developed, however, with its potential for sustained release of bioactive growth factors and small molecules, may be loaded with other desired compounds, with or without EGF, to accelerate the process of wound healing. PMID:25729882

  11. Evaluation of lumbar segmental instability in degenerative diseases by using a new intraoperative measurement system.

    PubMed

    Hasegawa, Kazuhiro; Kitahara, Ko; Hara, Toshiaki; Takano, Ko; Shimoda, Haruka; Homma, Takao

    2008-03-01

    In vivo quantitative measurement of lumbar segmental stability has not been established. The authors developed a new measurement system to determine intraoperative lumbar stability. The objective of this study was to clarify the biomechanical properties of degenerative lumbar segments by using the new method. Twenty-two patients with a degenerative symptomatic segment were studied and their measurements compared with those obtained in normal or asymptomatic degenerative segments (Normal group). The measurement system produces cyclic flexion-extension through spinous process holders by using a computer-controlled motion generator with all ligamentous structures intact. The following biomechanical parameters were determined: stiffness, absorption energy (AE), and neutral zone (NZ). Discs with degeneration were divided into 2 groups based on magnetic resonance imaging grading: degeneration without collapse (Collapse[-]) and degeneration with collapse (Collapse[+]). Biomechanical parameters were compared among the groups. Relationships among the biomechanical parameters and age, diagnosis, or radiographic parameters were analyzed. The mean stiffness value in the Normal group was significantly greater than that in Collapse(-) or Collapse(+) group. There was no significant difference in the average AE value among the Normal, Collapse(-), and Collapse(+) groups. The NZ in the Collapse(-) was significantly higher than in the Normal or Collapse(+) groups. Stiffness was negatively and NZ was positively correlated with age. Stiffness demonstrated a significant negative and NZ a significant positive relationship with disc height, however. There were no significant differences in stiffness between spines in the Collapse(-) and Collapse(+) groups. The values of a more sensitive parameter, NZ, were higher in Collapse(-) than in Collapse(+) groups, demonstrating that degenerative segments with preserved disc height have a latent instability compared to segments with collapsed discs.

  12. Parapercis nigrodorsalis (Perciformes: Pinguipedidae), a new species of sandperch from northern New Zealand and the Norfolk Ridge, Tasman Sea and remarks on P. binivirgata (Waite, 1904).

    PubMed

    Johnson, Jeffrey W; Struthers, Carl D; Wilmer, Jessica Worthington

    2014-08-26

    A new species of pinguipedid fish, Parapercis nigrodorsalis, is described from 17 specimens collected off the North Island of New Zealand and Wanganella Bank, Norfolk Ridge, Tasman Sea, in depths of 56-280 m. The species has also been photographed underwater off the Poor Knights Islands Reserve and Burgess Island, Mokohinau Group, in New Zealand. It is most similar to Parapercis binivirgata (Waite, 1904) in morphology, coloration and meristic values, but is unique among the genus in having a combination of dorsal-fin rays V, 23, anal-fin rays I, 19, lateral-line scales 57-63, vomer with 1-2 irregular rows of robust conical teeth, palatines with 1-2 rows of small teeth, angle of subopercle smooth, 10 abdominal and 22 caudal vertebrae, and coloration, including seven broad reddish-brown bands on the upper body between the spinous dorsal-fin and the caudal peduncle, most bands bifurcated into close-set double bars with black smudge-like blotches below, and membrane of the spinous dorsal fin black. Comparison of the mitochondrial cytochrome c oxidase subunit 1 (CO 1) genetic marker utilised in DNA barcoding produced a genetic divergence of 5.38% and 7.63% between the new species and its two closest sampled congeners. The holotype of P. binivirgata is identified from two specimens previously regarded as syntypes, some revisions are made to meristic data in the original description of the latter, and a detailed description of the revised geographic range of P. binivirgata is provided.  

  13. Maternal pelvic dimensions and neonatal size: Implications for growth plasticity in early life as adaptation.

    PubMed

    Wells, Jonathan C K; Figueiroa, José N; Alves, Joao G

    2017-01-01

    Patterns of fetal growth predict non-communicable disease risk in adult life, but fetal growth variability appears to have a relatively weak association with maternal nutritional dynamics during pregnancy. This challenges the interpretation of fetal growth variability as 'adaptation'. We hypothesized that associations of maternal size and nutritional status with neonatal size are mediated by the dimensions of the maternal pelvis. We analysed data on maternal height, body mass index (BMI) and pelvic dimensions (conjugate, inter-spinous and inter-cristal diameters) and neonatal gestational age, weight, length, thorax girth and head girth ( n = 224). Multiple regression analysis was used to identify independent maternal predictors of neonatal size, and the mediating role of neonatal head girth in these associations. Pelvic dimensions displaced maternal BMI as a predictor of birth weight, explaining 11.6% of the variance. Maternal conjugate and inter-spinous diameters predicted neonatal length, thorax girth and head girth, whereas inter-cristal diameter only predicted neonatal length. Associations of pelvic dimensions with birth length, but not birth weight, were mediated by neonatal head girth. Pelvic dimensions predicted neonatal size better than maternal BMI, and these associations were mostly independent of maternal height. Sensitivity of fetal growth to pelvic dimensions reduces the risk of cephalo-pelvic disproportion, potentially a strong selective pressure during secular trends in height. Selection on fetal adaptation to relatively inflexible components of maternal phenotype, rather than directly to external ecological conditions, may help explain high levels of growth plasticity during late fetal life and early infancy.

  14. Effects of Ascorbyl-2-phosphate Magnesium on Human Keratinocyte Toxicity and Pathological Changes by Sorafenib.

    PubMed

    Yamamoto, Kazuhiro; Shichiri, Hiroaki; Ishida, Takahiro; Kaku, Kenta; Nishioka, Tatsuya; Kume, Manabu; Makimoto, Hiroo; Nakagawa, Tsutomu; Hirano, Takeshi; Bito, Toshinori; Nishigori, Chikako; Yano, Ikuko; Hirai, Midori

    2017-01-01

    Hand-foot skin reaction is recognized as one of the most common adverse events related to multiple tyrosine kinase inhibitors, but an effective prevention method has not been identified. The chief aim of this study was to find a mechanism-based preventive method for the skin toxicity induced by sorafenib using vitamin C derivatives. The effects of ascorbyl-2-phosphate magnesium (P-VC-Mg) on the molecular and pathological changes induced by sorafenib were investigated in human keratinocyte HaCaT cells. The cell growth inhibition and apoptotic effects of sorafenib were attenuated by P-VC-Mg. Moreover, P-VC-Mg inhibited the decrease of signal transducer and activator of transcription 3 (STAT3) phosphorylation and the expression of apoptosis suppressors treated by sorafenib. HaCaT cells transfected with the STAT3 dominant-negative form (STAT3DN) and STAT3 small interfering RNA (siRNA) combined with P-VC-Mg did not exhibit the attenuation of cell growth inhibition. Interestingly, after exposure to sorafenib in a three dimensional (3D) skin model assay, the basal layer was significantly thickened and the granular and spinous layers became thinner. In contrast, after exposure to sorafenib with P-VC-Mg, the thickness of the basal, granular, and spinous layers was similar to that of the control image. These findings suggest that P-VC-Mg attenuates sorafenib-induced apoptosis and pathological changes in human keratinocyte cells and in the 3D skin model mediated by the maintenance of STAT3 activity.

  15. Long-term actuarial survivorship analysis of an interspinous stabilization system

    PubMed Central

    Sénégas, Jacques; Pointillart, Vincent; Mangione, Paolo

    2007-01-01

    In 1986, an interspinous dynamic stabilization system (the prototype of the current Wallis implant) was designed to stiffen unstable operated degenerate lumbar segments with a hard interspinous blocker to limit extension and a tension band around the spinous processes to secure the implant and limit flexion. Restoring physiological mechanical conditions to the treated level(s) while preserving some intervertebral mobility was intended to treat low-back pain related to degenerative instability without increasing stress forces in the adjacent segments. The procedure was easily reversible. If low back pain persisted or recurred, the device was removed and stability was achieved using fusion. The intermediate-term results were promising, but the long-term safety and efficacy of this dynamic interspinous stabilization device has not been previously documented. We retrospectively reviewed the hospital files of all the patients (n = 241) who had this dynamic stabilization system implanted between 1987 and 1995, contacting as many as possible to determine the actuarial survivorship of the system. In this manner, 142 of the 241 patients (58.9%) were contacted by telephone. The endpoints used for the survivorship analysis were ‘any subsequent lumbar operation’ and ‘implant removal’. At 14 years follow-up, values of actuarial survivorship with 95% confidence interval were 75.9 ± 8.3 and 81.3 ± 6.8% for the endpoints ‘any subsequent lumbar operation’ and ‘implant removal’, respectively. There was no difference in survivorship of multiple-level implants with respect to single-level devices. Although the conclusions of the present study must be tempered by the 41% attrition rate, these findings support the long-term safety of this system, and possibly long-term protective action against adjacent-level degeneration by motion preservation. Outcomes at least equivalent to those of fusion were observed without the primary drawbacks of fusion. PMID:17426988

  16. Agreement between Fiber Optic and Optoelectronic Systems for Quantifying Sagittal Plane Spinal Curvature in Sitting

    PubMed Central

    Cloud, Beth A.; Zhao, Kristin D.; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-01-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n=26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R2=0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95%LOA: −3.43-12.04°), 3.64° (95%LOA: −1.07-8.36°), and 4.02° (95%LOA: −2.80-10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures is 2.86° (95%LOA: −1.18-6.90°) and 2.55° (95%LOA: −3.38-8.48°), respectively. In natural sitting, the mean±SD of kyphosis values was 35.07± 6.75°. Lordosis was detected in 8/26 participants: 11.72±7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. PMID:24909579

  17. Percutaneous computer-assisted translaminar facet screw: an initial human cadaveric study.

    PubMed

    Sasso, Rick C; Best, Natalie M; Potts, Eric A

    2005-01-01

    Translaminar facet screws are a minimally invasive technique for posterior lumbar fixation with good success rates. Computer-assisted image navigation using virtual fluoroscopy allows multiple simultaneous screens in various planes to plan and drive spinal instrumentation. This study evaluates the percutaneous placement of translaminar facet screws with the use of virtual fluoroscopy as an image guidance technique. A human cadaveric study was performed with a percutaneous reference frame applied to the iliac crest. Ten translaminar facet screws were placed bilaterally at five levels. Anteroposterior and lateral images were used to navigate 4.0-mm screws through a percutaneous portal under virtual fluoroscopy. An axial computed tomographic scan through the instrumented levels was obtained after the screws were placed. Screws were graded on entry, course through the lamina, and terminus. A grading system was devised to grade the course through the lamina. All 10 screw-entry points were judged optimal at the spinous process laminar junction. There were five Grade I breeches with less than 1/2 the screw through the lamina, and five Grade 0 screw placements with the screw contained completely within the lamina. The termination point was acceptable in five screws. The screws that began on the right and terminated on the left were all found to have grade II breakouts. No screws placed the spinal canal or exiting nerve root at risk. Virtual fluoroscopy provides significant assistance in percutaneous placement of translaminar facet screws and results in safe position of entry, lamina course, and terminus.

  18. Error analysis on spinal motion measurement using skin mounted sensors.

    PubMed

    Yang, Zhengyi; Ma, Heather Ting; Wang, Deming; Lee, Raymond

    2008-01-01

    Measurement errors of skin-mounted sensors in measuring forward bending movement of the lumbar spines are investigated. In this investigation, radiographic images capturing the entire lumbar spines' positions were acquired and used as a 'gold' standard. Seventeen young male volunteers (21 (SD 1) years old) agreed to participate in the study. Light-weight miniature sensors of the electromagnetic tracking systems-Fastrak were attached to the skin overlying the spinous processes of the lumbar spine. With the sensors attached, the subjects were requested to take lateral radiographs in two postures: neutral upright and full flexion. The ranges of motions of lumbar spine were calculated from two sets of digitized data: the bony markers of vertebral bodies and the sensors and compared. The differences between the two sets of results were then analyzed. The relative movement between sensor and vertebrae was decomposed into sensor sliding and titling, from which sliding error and titling error were introduced. Gross motion range of forward bending of lumbar spine measured from bony markers of vertebrae is 67.8 degrees (SD 10.6 degrees ) and that from sensors is 62.8 degrees (SD 12.8 degrees ). The error and absolute error for gross motion range were 5.0 degrees (SD 7.2 degrees ) and 7.7 degrees (SD 3.9 degrees ). The contributions of sensors placed on S1 and L1 to the absolute error were 3.9 degrees (SD 2.9 degrees ) and 4.4 degrees (SD 2.8 degrees ), respectively.

  19. Mechanisms and factors involved in hip injuries during frontal crashes.

    PubMed

    Yoganandan, N; Pintar, F A; Gennarelli, T A; Maltese, M R; Eppinger, R H

    2001-11-01

    This study was conducted to collect data and gain insights relative to the mechanisms and factors involved in hip injuries during frontal crashes and to study the tolerance of hip injuries from this type of loading. Unembalmed human cadavers were seated on a standard automotive seat (reinforced) and subjected to knee impact test to each lower extremity. Varying combinations of flexion and adduction/abduction were used for initial alignment conditions and pre-positioning. Accelerometers were fixed to the iliac wings and twelfth thoracic vertebral spinous process. A 23.4-kg padded pendulum impacted the knee at velocities ranging from 4.3 to 7.6 m/s. The impacting direction was along the anteroposterior axis, i.e., the global X-axis, in the body-fixed coordinate system. A load cell on the front of the pendulum recorded the impact force. Peak impact forces ranged from 2,450 to 10,950 N. The rate of loading ranged from 123 to 7,664 N/msec. The impulse values ranged from 12.4 to 31.9 Nsec. Injuries were not apparent in three tests. Eight tests resulted in trauma. Fractures involving the pelvis including the acetabulum and proximal femur occurred in five out of the eight tests, and distal femoral bone fracture occurred in one test. These results underscore the importance of leg pre-positioning and the orientation of the impacting axis to produce specific types of trauma to the pelvic region of the lower extremity.

  20. Effect of spinal manipulation on the development of history-dependent responsiveness of lumbar paraspinal muscle spindles in the cat

    PubMed Central

    Cao, Dong-Yuan; Pickar, Joel G.

    2014-01-01

    We determined whether spinal manipulation could prevent and/or reverse the decrease and increase in paraspinal muscle spindle responsiveness caused respectively by lengthening and shortening histories of the lumbar muscles. Single unit spindle activity from multifidus and longissimus muscles was recorded in the L6 dorsal root in anesthetized cats. Muscle history was created and spinal manipulation delivered (thrust amplitude: 1.0mm, duration: 100ms) using a feedback-controlled motor attached to the L6 spinous process. Muscle spindle discharge to a fixed vertebral position (static test) and to vertebral movement (dynamic test) was evaluated following the lengthening and shortening histories. For the static test, changes in muscle spindle responsiveness were significantly less when spinal manipulation followed muscle history (p<0.01), but not when spinal manipulation preceded it (p>0.05). For the dynamic test, spinal manipulation did not significantly affect the history-induced change in muscle spindle responsiveness. Spinal manipulation may partially reverse the effects of muscle history on muscle spindle signaling of vertebral position. PMID:24932019

  1. The relationship between forward head posture and temporomandibular disorders.

    PubMed

    Lee, W Y; Okeson, J P; Lindroth, J

    1995-01-01

    This study investigated the relationship between forward head posture and temporomandibular disorder symptoms. Thirty-three temporomandibular disorder patients with predominant complaints of masticatory muscle pain were compared with an age- and gender-matched control group. Head position was measured from photographs taken with a plumb line drawn from the ceiling to the lateral malleolus of the ankle and with a horizontal plane that was perpendicular to the plumb line and that passed through the spinous process of the seventh cervical vertebra. The distances from the plumb line to the ear, to the seventh vertebra, and to the shoulder were measured. Two angles were also measured: (1) ear-seventh cervical vertebra-horizontal plane and (2) eye-ear-seventh cervical vertebra. The only measurement that revealed a statistically significant difference was angle ear-seventh cervical vertebra-horizontal plane. This angle was smaller in the patients with temporomandibular disorders than in the control subjects. In other words, when evaluating the ear position with respect to the seventh cervical vertebra, the head was positioned more forward in the group with temporomandibular disorders than in the control group (P < .05).

  2. Sensitivity studies of pediatric material properties on juvenile lumbar spine responses using finite element analysis.

    PubMed

    Jebaseelan, D Davidson; Jebaraj, C; Yoganandan, Narayan; Rajasekaran, S; Kanna, Rishi M

    2012-05-01

    The objective of the study was to determine the sensitivity of material properties of the juvenile spine to its external and internal responses using a finite element model under compression, and flexion-extension bending moments. The methodology included exercising the 8-year-old juvenile lumbar spine using parametric procedures. The model included the vertebral centrum, growth plates, laminae, pedicles, transverse processes and spinous processes; disc annulus and nucleus; and various ligaments. The sensitivity analysis was conducted by varying the modulus of elasticity for various components. The first simulation was done using mean material properties. Additional simulations were done for each component corresponding to low and high material property variations. External displacement/rotation and internal stress-strain responses were determined under compression and flexion-extension bending. Results indicated that, under compression, disc properties were more sensitive than bone properties, implying an elevated role of the disc under this mode. Under flexion-extension moments, ligament properties were more dominant than the other components, suggesting that various ligaments of the juvenile spine play a key role in modulating bending behaviors. Changes in the growth plate stress associated with ligament properties explained the importance of the growth plate in the pediatric spine with potential implications in progressive deformities.

  3. Procedure Selection and Patient Positioning Influence Spine Kinematics During High-Velocity, Low-Amplitude Spinal Manipulation Applied to the Low Back.

    PubMed

    Bell, Spencer; D'Angelo, Kevin; Kawchuk, Gregory N; Triano, John J; Howarth, Samuel J

    This investigation compared indirect 3-dimensional angular kinematics (position, velocity, and acceleration) of the lumbar spine for 2 different high-velocity, low-amplitude (HVLA) spinal manipulation procedures (lumbar spinous pull or push), and altered initial patient lower limb posture. Twenty-four participants underwent 6 HVLA procedures directed toward the presumed L4 vertebra, reflecting each combination of 2 variants of a spinal manipulation application technique (spinous pull and push) and 3 initial hip flexion angles (0°, 45°, and 90°) applied using a right lateral recumbent patient position. All contact forces and moments between the patient and the external environment, as well as 3-dimensional kinematics of the patient's pelvis and thorax, were recorded. Lumbar spine angular positions, velocities, and accelerations were analyzed within the preload and impulse stages of each HVLA trial. Lumbar spine left axial rotation was greater for the pull HVLA. The pull HVLA also generated a greater maximum (leftward) and lower minimum (rightward) axial rotation velocity and deceleration and greater leftward and rightward lateral bend velocities, acceleration, and deceleration components. Not flexing the hip produced the greatest amount of extension, as well as the lowest axial rotation and maximum axial rotation acceleration during the impulse. This investigation provides basic kinematic information for clinicians to understand the similarities and differences between 2 HVLA side-lying manipulations in the lumbar spine. Use of these findings and novel technology can drive future research initiatives that can both affect clinical decision making and influence teaching environments surrounding spinal manipulative therapy skill acquisition. Copyright © 2017. Published by Elsevier Inc.

  4. Differential transmission of the molecular signature of RBSP3, LIMD1 and CDC25A in basal/ parabasal versus spinous of normal epithelium during head and neck tumorigenesis: A mechanistic study.

    PubMed

    Sarkar, Shreya; Alam, Neyaz; Mandal, Syam Sundar; Chatterjee, Kabita; Ghosh, Supratim; Roychoudhury, Susanta; Panda, Chinmay Kumar

    2018-01-01

    Head and neck squamous cell carcinoma (HNSCC) is a global disease and mortality burden, necessitating the elucidation of its molecular progression for effective disease management. The study aims to understand the molecular profile of three candidate cell cycle regulatory genes, RBSP3, LIMD1 and CDC25A in the basal/ parabasal versus spinous layer of normal oral epithelium and during head and neck tumorigenesis. Immunohistochemical expression and promoter methylation was used to determine the molecular signature in normal oral epithelium. The mechanism of alteration transmission of this profile during tumorigenesis was then explored through additional deletion and mutation in HPV/ tobacco etiological groups, followed byclinico-pathological correlation. In basal/parabasal layer, the molecular signature of the genes was low protein expression/ high promoter methylation of RBSP3, high expression/ low methylation of LIMD1 and high expression of CDC25A. Dysplastic epithelium maintained the signature of RBSP3 through high methylation/ additional deletion with loss of the signatures of LIMD1 and CDC25A via deletion/ additional methylation. Similarly, maintenance and / or loss of signature in invasive tumors was by recurrent deletion/ methylation. Thus, differential patterns of alteration of the genes might be pre-requisite for the development of dysplastic and invasive lesions. Etiological factors played a key role in promoting genetic alterations and determining prognosis. Tobacco negative HNSCC patients had significantly lower alterations of LIMD1 and CDC25A, along with better survival among tobacco negative/ HPV positive patients. Our data suggests the necessity for perturbation of normal molecular profile of RBSP3, LIMD1 and CDC25A in conjunction with etiological factors for head and neck tumorigenesis, implying their diagnostic and prognostic significance.

  5. Structural and ultrastructural features of the agouti tongue (Dasyprocta aguti Linnaeus, 1766)

    PubMed Central

    Ciena, Adriano Polican; Bolina, Cristina de Sousa; de Almeida, Sonia Regina Yokomizo; Rici, Rose Eli Grassi; de Oliveira, Moacir Franco; da da Silva, Marcelo Cavenaghi Pereira; Miglino, Maria Angélica; Watanabe, Ii-sei

    2013-01-01

    The agouti (Dasyprocta aguti Linnaeus, 1766) is a wild rodent belonging to the family Dasyproctidae that is found throughout Brazil and feeds on fruits and seeds. The aim of the present study was to describe the following features of the tongue of agouti: its morphological structures, the three-dimensional characteristics of the lingual papillae surface, the connective tissue cores (CTCs) and the epithelial cell ultrastructure. Four types of papillae were observed on the dorsal surface of the tongue with a triangular shape: filiform, fungiform, foliate and vallate. Filiform papillae were distributed throughout the tongue surface, and removal of the epithelial surface revealed conical CTCs and multifilaments. Fungiform papillae were observed in the rostral and middle regions, whereas foliate papillae developed in pairs on the lateral margin of the caudal region. Removal of the epithelium in these regions revealed CTCs with parallel laminar conformation. Vallate papillae were arranged in a V-shape in the caudal region, and their CTCs ranged in shape from elongate to ovoid. The ultrastructural components of the dorsal epithelium were the basal, spinous, granular and keratinised layers. A broad area with cytoplasmic projections was identified in the interface region between the lamina propria and the basal layer. Flattened cells with intermediate filaments were observed in the transitional region between spinous and granular layers. The keratinised layer was composed of superimposed epithelial cells where desmosomes and cell-surface microridges were observed. These structural features, including the three-dimensional aspects of the lingual papillae, the CTCs and the epithelial ultrastructure, indicate that when compared with other animals, particularly other rodent species, the morphological features of the tongue of agouti are relatively well developed, especially regarding foliate and vallate papillae. PMID:23701183

  6. Expression pattern of adhesion molecules in junctional epithelium differs from that in other gingival epithelia.

    PubMed

    Hatakeyama, S; Yaegashi, T; Oikawa, Y; Fujiwara, H; Mikami, T; Takeda, Y; Satoh, M

    2006-08-01

    The gingival epithelium is the physiologically important interface between the bacterially colonized gingival sulcus and periodontal soft and mineralized connective tissues, requiring protection from exposure to bacteria and their products. However, of the three epithelia comprising the gingival epithelium, the junctional epithelium has much wider intercellular spaces than the sulcular epithelium and oral gingival epithelium. Hence, the aim of the present study was to characterize the cell adhesion structure in the junctional epithelium compared with the other two epithelia. Gingival epithelia excised at therapeutic flap surgery from patients with periodontitis were examined for expression of adhesion molecules by immunofluorescence. In the oral gingival epithelium and sulcular epithelium, but not in the junctional epithelium, desmoglein 1 and 2 in cell-cell contact sites were more abundant in the upper than the suprabasal layers. E-cadherin, the main transmembranous molecule of adherens junctions, was present in spinous layers of the oral gingival epithelium and sulcular epithelium, but was scarce in the junctional epithelium. In contrast, desmoglein 3 and P-cadherin were present in all layers of the junctional epithelium as well as the oral gingival epithelium and sulcular epithelium. Connexin 43 was clearly localized to spinous layers of the oral gingival epithelium, sulcular epithelium and parts of the junctional epithelium. Claudin-1 and occludin were expressed in the cell membranes of a few superficial layers of the oral gingival epithelium. These findings indicated that the junctional epithelium contains only a few desmosomes, composed of only desmoglein 3; adherens junctions are probably absent because of defective E-cadherin. Thus, the anchoring junctions connecting junctional epithelium cells are lax, causing widened intercellular spaces. In contrast, the oral gingival epithelium, which has a few tight junctions, functions as a barrier.

  7. The use of a latissimus dorsi muscle flap for scapular reconstruction in a cat following fibrosarcoma excision.

    PubMed

    Canapp, S O; Mann, F A; Henry, C J; Lattimer, J C

    2001-01-01

    A latissimus dorsi muscle flap was used to reconstruct a proximal scapular defect in a cat after excision of a fibrosarcoma that had recurred after eight surgeries, radiation therapy, and chemotherapy. To obtain appropriate surgical margins, infraspinatus and supraspinatus myectomy and scapular spinous ostectomy were performed. The latissimus dorsi muscle flap was rotated into the defect and anchored to four holes placed in the cranial border of the scapula. The cat showed no lameness at 6, 21, 42, and 147 days after surgery. The latissimus dorsi muscle flap was successful for proximal scapular reconstruction in this cat.

  8. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting.

    PubMed

    Cloud, Beth A; Zhao, Kristin D; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-07-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n = 26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R(2) = 0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95% LOA: -3.43 to 12.04°), 3.64° (95% LOA: -1.07 to 8.36°), and 4.02° (95% LOA: -2.80 to 10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures was 2.86° (95% LOA: -1.18 to 6.90°) and 2.55° (95% LOA: -3.38 to 8.48°), respectively. In natural sitting, the mean ± SD of kyphosis values was 35.07 ± 6.75°. Lordosis was detected in 8/26 participants: 11.72 ± 7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The birth canal: correlation between the pubic arch angle, the interspinous diameter, and the obstetrical conjugate: a computed tomography biometric study in reproductive age women.

    PubMed

    Perlman, Sharon; Raviv-Zilka, Lisa; Levinsky, Denis; Gidron, Ayelet; Achiron, Reuven; Gilboa, Yinon; Kivilevitch, Zvi

    2018-04-22

    Assessment of pelvic configuration is an important factor in the prediction of a successful vaginal birth. However, manual evaluation of the pelvis is practically a vanishing art, and imaging techniques are not available as a real-time bed-side tool. Unlike the obstetrical conjugate diameter (OC) and inter spinous diameter (ISD), the pubic arch angle (PAA) can be easily measured by transperineal ultrasound. Three-dimensional computed tomography bone reconstructions were used to measure the three main birth canal diameters, evaluate the correlation between them, and establish the normal reference range for the inlet, mid-, and pelvic outlet. Measurements of the PAA, obstetric conjugate (OC), and ISD were performed offline using three-dimensional post processing reconstruction in bone algorithm application of the pelvis on examinations performed for suspected renal colic in nonpregnant reproductive age woman. The mean of two measurements was used for statistical analysis which included reproducibility of measurements, regression curve estimation between PAA, OC, and ISD, and calculation of the respective reference range centiles for each PAA degree. Two hundred ninety-eight women comprised the study group. The mean ± SD of the PAA, ISD, and OC were 104.9° (±7.4), 103.8 mm (±7.3), and 129.9 mm (±8.3), respectively. The intra- and interobserver agreement defined by the intraclass correlation coefficient (ICC) was excellent for all parameters (range 0.905-0.993). A significant positive correlation was found between PAA and ISD and between PAA and OCD (Pearson's correlation = 0.373 (p < .001), and 0.163 (p = .022), respectively). The best regression formula was found with quadratic regression for inter spinous diameter (ISD): 34.122778 + (0.962182*PAA - 0.002830*PAA 2 ), and linear regression for obstetric conjugate (OC): 110.638397 + 0.183156*PAA. Modeled mean, SD, and reference centiles of the ISD and OCD were calculated using the above regression models as function of the PAA. We report significant correlation between the three pelvic landmarks with greatest impact on the prediction of a successful vaginal delivery: the PAA which is easily measured sonographically and the ISD and OC which are not measurable by ultrasound. This correlation may serve as a basis for future studies to assess its utility and prognostic value for a safe vaginal delivery.

  10. Establishment of a Method to Measure Length of the Ulnar Nerve and Standardize F-wave Values in Clinically Normal Beagles

    PubMed Central

    HIRASAWA, Shun; SHIMIZU, Miki; MARUI, Yuumi; KISHIMOTO, Miori; OKUNO, Seiichi

    2014-01-01

    We designed a new method of measuring the length of the ulnar nerve and determining standard values for F-wave parameters of the ulnar nerve in clinically normal beagles. Nerve length must be precisely measured to determine F-wave latency and conduction velocity. The length of the forelimb has served as the length of the ulnar nerve for F-wave assessments, but report indicates that F-wave latency is proportional to the length of the pathway traveled by nerve impulses. Therefore, we measured the surface distance from a stimulus point to the spinous process of the first thoracic vertebra (nerve length 1) and the anterior horn of the scapula (nerve length 2) as landmarks through the olecranon and the shoulder blade acromion. The correlation coefficients between the shortest F-wave latency and the length of nerves 1, 2 or the forelimb were 0.61, 0.7 and 0.58. Nerve length 2 generated the highest value. Furthermore, the anterior horn of the scapula was easily palpated in any dog regardless of well-fed body. We concluded that nerve length 2 was optimal for measuring the length of the ulnar nerve. PMID:25649942

  11. Halovest treatment in traumatic cervical spine injury.

    PubMed

    Razak, M; Basir, T; Hyzan, Y; Johari, Z

    1998-09-01

    This is a cross-sectional study on the use of halovest appliance in the Orthopaedic and Traumatology Department, Kuala Lumpur Hospital from June 1993 to September 1996. Fifty-three patients with cervical spine injuries were treated by halovest stabilization. Majority of cases was caused by motor-vehicle accident; others were fall from height at construction sites, fall at home, hit by falling object and assault. The injuries were Jefferson fracture of C1, odontoid fractures, hangman fractures, open spinous process fracture and fracture body of C2, and fracture, and fracture-dislocation of the lower cervical spines. Majority of patients had hospital stay less than 30 days. The use of the halovest ranges from 4 to 16 weeks and the healing rate was 96%. Two patients of lower cervical spine injury had redislocation and one of them was operated. There was one case of non-union of type II odontoid fracture and treated by posterior fusion. Other complications encountered during halovest treatment were minor. They were pin-site infection, pin-loosening, clamp loosening and neck pain or neck stiffness. This method of treatment enables patient to ambulate early and reduces hospital stay. We found that halovest is easy to apply, safe and tolerable to most of the patients.

  12. Smartphone confocal microscopy for imaging cellular structures in human skin in vivo.

    PubMed

    Freeman, Esther E; Semeere, Aggrey; Osman, Hany; Peterson, Gary; Rajadhyaksha, Milind; González, Salvador; Martin, Jeffery N; Anderson, R Rox; Tearney, Guillermo J; Kang, Dongkyun

    2018-04-01

    We report development of a low-cost smartphone confocal microscope and its first demonstration of in vivo human skin imaging. The smartphone confocal microscope uses a slit aperture and diffraction grating to conduct two-dimensional confocal imaging without using any beam scanning devices. Lateral and axial resolutions of the smartphone confocal microscope were measured as 2 and 5 µm, respectively. In vivo confocal images of human skin revealed characteristic cellular structures, including spinous and basal keratinocytes and papillary dermis. Results suggest that the smartphone confocal microscope has a potential to examine cellular details in vivo and may help disease diagnosis in resource-poor settings, where conducting standard histopathologic analysis is challenging.

  13. Smartphone confocal microscopy for imaging cellular structures in human skin in vivo

    PubMed Central

    Freeman, Esther E.; Semeere, Aggrey; Osman, Hany; Peterson, Gary; Rajadhyaksha, Milind; González, Salvador; Martin, Jeffery N.; Anderson, R. Rox; Tearney, Guillermo J.; Kang, Dongkyun

    2018-01-01

    We report development of a low-cost smartphone confocal microscope and its first demonstration of in vivo human skin imaging. The smartphone confocal microscope uses a slit aperture and diffraction grating to conduct two-dimensional confocal imaging without using any beam scanning devices. Lateral and axial resolutions of the smartphone confocal microscope were measured as 2 and 5 µm, respectively. In vivo confocal images of human skin revealed characteristic cellular structures, including spinous and basal keratinocytes and papillary dermis. Results suggest that the smartphone confocal microscope has a potential to examine cellular details in vivo and may help disease diagnosis in resource-poor settings, where conducting standard histopathologic analysis is challenging. PMID:29675328

  14. Three-dimensional morphometrics of thoracic vertebrae in Neandertals and the fossil evidence from El Sidrón (Asturias, Northern Spain).

    PubMed

    Bastir, Markus; García Martínez, Daniel; Rios, Luis; Higuero, Antonio; Barash, Alon; Martelli, Sandra; García Tabernero, Antonio; Estalrrich, Almudena; Huguet, Rosa; de la Rasilla, Marco; Rosas, Antonio

    2017-07-01

    Well preserved thoracic vertebrae of Neandertals are rare. However, such fossils are important as their three-dimensional (3D) spatial configuration can contribute to the understanding of the size and shape of the thoracic spine and the entire thorax. This is because the vertebral body and transverse processes provide the articulation and attachment sites for the ribs. Dorsal orientation of the transverse processes relative to the vertebral body also rotates the attached ribs in a way that could affect thorax width. Previous research indicates possible evidence for greater dorsal orientation of the transverse processes and small vertebral body heights in Neandertals, but their 3D vertebral structure has not yet been addressed. Here we present 15 new vertebral remains from the El Sidrón Neandertals (Asturias, Northern Spain) and used 3D geometric morphometrics to address the above issues by comparing two particularly well preserved El Sidrón remains (SD-1619, SD-1641) with thoracic vertebrae from other Neandertals and a sample of anatomically modern humans. Centroid sizes of El Sidrón vertebrae are within the human range. Neandertals have larger T1 and probably also T2. The El Sidrón vertebrae are similar in 3D shape to those of other Neandertals, which differ from Homo sapiens particularly in central-lower regions (T6-T10) of the thoracic spine. Differences include more dorsally and cranially oriented transverse processes, less caudally oriented spinous processes, and vertebral bodies that are anteroposteriorly and craniocaudally short. The results fit with current reconstructions of Neandertal thorax morphology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Identification of greater occipital nerve landmarks for the treatment of occipital neuralgia.

    PubMed

    Loukas, M; El-Sedfy, A; Tubbs, R S; Louis, R G; Wartmann, C H T; Curry, B; Jordan, R

    2006-11-01

    Important structures involved in the pathogenesis of occipital headache include the aponeurotic attachments of the trapezius and semispinalis capitis muscles to the occipital bone. The greater occipital nerve (GON) can become entrapped as it passes through these aponeuroses, causing symptoms of occipital neuralgia. The aim of this study was to identify topographic landmarks for accurate identification of GON, which might facilitate its anaesthetic blockade. The course and distribution of GON and its relation to the aponeuroses of the trapezius and semispinalis capitis were examined in 100 formalin-fixed adult cadavers. In addition, the relative position of the nerve on a horizontal line between the external occipital protuberance and the mastoid process, as well as between the mastoid processes was measured. The greater occipital nerve was found bilaterally in all specimens. It was located at a mean distance of 3.8 cm (range 1.5-7.5 cm) lateral to a vertical line through the external occipital protuberance and the spinous processes of the cervical vertebrae 2-7. It was also located approximately 41% of the distance along the intermastoid line (medial to a mastoid process) and 22% of the distance between the external occipital protuberance and the mastoid process. The location of GON for anaesthesia or any other neurosurgical procedure has been established as one thumb's breadth lateral to the external occipital protuberance (2 cm laterally) and approximately at the base of the thumb nail (2 cm inferior). This is the first study proposing the use of landmarks in relation to anthropometric measurements. On the basis of these observations we propose a target zone for local anaesthetic injection that is based on easily identifiable landmarks and suggest that injection at this target point could be of benefit in the relief of occipital neuralgia.

  16. Response of lumbar paraspinal muscles spindles is greater to spinal manipulative loading compared with slower loading under length control.

    PubMed

    Pickar, Joel G; Sung, Paul S; Kang, Yu-Ming; Ge, Weiqing

    2007-01-01

    Spinal manipulation (SM) is a form of manual therapy used clinically to treat patients with low back and neck pain. The most common form of this maneuver is characterized as a high-velocity (duration <150 ms), low-amplitude (segmental translation <2 mm, rotation <4 degrees , and applied force 220-889 N) impulse thrust (high-velocity, low-amplitude spinal manipulation [HVLA-SM]). Clinical skill in applying an HVLA-SM lies in the practitioner's ability to control the duration and magnitude of the load (ie, the rate of loading), the direction in which the load is applied, and the contact point at which the load is applied. Control over its mechanical delivery is presumably related to its clinical effects. Biomechanical changes evoked by an HVLA-SM are thought to have physiological consequences caused, at least in part, by changes in sensory signaling from paraspinal tissues. If activation of afferent pathways does contribute to the effects of an HVLA-SM, it seems reasonable to anticipate that neural discharge might increase or decrease in a nonlinear fashion as the thrust duration approaches a threshold value. We hypothesized that the relationship between the duration of an impulsive thrust to a vertebra and paraspinal muscle spindle discharge would be nonlinear with an inflection near the duration of an HVLA-SM delivered clinically (<150 ms). In addition, we anticipated that muscle spindle discharge would be more sensitive to larger amplitude thrusts. A neurophysiological study of spinal manipulation using the lumbar spine of a feline model. Impulse thrusts (duration: 12.5, 25, 50, 100, 200, and 400 ms; amplitude 1 or 2 mm posterior to anterior) were applied to the spinous process of the L6 vertebra of deeply anesthetized cats while recording single unit activity from dorsal root filaments of muscle spindle afferents innervating the lumbar paraspinal muscles. A feedback motor was used in displacement control mode to deliver the impulse thrusts. The motor's drive arm was securely attached to the L6 spinous process via a forceps. As thrust duration became shorter, the discharge of the lumbar paraspinal muscle spindles increased in a curvilinear fashion. A concave-up inflection occurred near the 100-ms duration eliciting both a higher frequency discharge compared with the longer durations and a substantially faster rate of change as thrust duration was shortened. This pattern was evident in paraspinal afferents with receptive fields both close and far from the midline. Paradoxically, spindle afferents were almost twice as sensitive to the 1-mm compared with the 2-mm amplitude thrust (6.2 vs. 3.3 spikes/s/mm/s). This latter finding may be related to the small versus large signal range properties of muscle spindles. The results indicate that the duration and amplitude of a spinal manipulation elicit a pattern of discharge from paraspinal muscle spindles different from slower mechanical inputs. Clinically, these parameters may be important determinants of an HVLA-SM's therapeutic benefit.

  17. Plane of vertebral movement eliciting muscle lengthening history in the low back influences the decrease in muscle spindle responsiveness of the cat

    PubMed Central

    Ge, Weiqing; Cao, Dong-Yuan; Long, Cynthia R.

    2011-01-01

    Proprioceptive feedback is thought to play a significant role in controlling both lumbopelvic and intervertebral orientations. In the lumbar spine, a vertebra's positional history along the dorsal-ventral axis has been shown to alter the position, movement, and velocity sensitivity of muscle spindles in the multifidus and longissimus muscles. These effects appear due to muscle history. Because spinal motion segments have up to 6 degrees of freedom for movement, we were interested in whether the axis along which the history is applied differentially affects paraspinal muscle spindles. We tested the null hypothesis that the loading axis, which creates a vertebra's positional history, has no effect on a lumbar muscle spindle's subsequent response to vertebral position or movement. Identical displacements were applied along three orthogonal axes directly at the L6 spinous process using a feedback motor system under displacement control. Single-unit nerve activity was recorded from 60 muscle spindle afferents in teased filaments from L6 dorsal rootlets innervating intact longissimus or multifidus muscles of deeply anesthetized cats. Muscle lengthening histories along the caudal-cranial and dorsal-ventral axis, compared with the left-right axis, produced significantly greater reductions in spindle responses to vertebral position and movement. The spinal anatomy suggested that the effect of a lengthening history is greatest when that history had occurred along an axis lying within the anatomical plane of the facet joint. Speculation is made that the interaction between normal spinal mechanics and the inherent thixotropic property of muscle spindles poses a challenge for feedback and feedforward motor control of the lumbar spine. PMID:21960662

  18. The effects of transducer geometry on artifacts common to diagnostic bone imaging with conventional medical ultrasound.

    PubMed

    Mauldin, F William; Owen, Kevin; Tiouririne, Mohamed; Hossack, John A

    2012-06-01

    The portability, low cost, and non-ionizing radiation associated with medical ultrasound suggest that it has potential as a superior alternative to X-ray for bone imaging. However, when conventional ultrasound imaging systems are used for bone imaging, clinical acceptance is frequently limited by artifacts derived from reflections occurring away from the main axis of the acoustic beam. In this paper, the physical source of off-axis artifacts and the effect of transducer geometry on these artifacts are investigated in simulation and experimental studies. In agreement with diffraction theory, the sampled linear-array geometry possessed increased off-axis energy compared with single-element piston geometry, and therefore, exhibited greater levels of artifact signal. Simulation and experimental results demonstrated that the linear-array geometry exhibited increased artifact signal when the center frequency increased, when energy off-axis to the main acoustic beam (i.e., grating lobes) was perpendicularly incident upon off-axis surfaces, and when off-axis surfaces were specular rather than diffusive. The simulation model used to simulate specular reflections was validated experimentally and a correlation coefficient of 0.97 between experimental and simulated peak reflection contrast was observed. In ex vivo experiments, the piston geometry yielded 4 and 6.2 dB average contrast improvement compared with the linear array when imaging the spinous process and interlaminar space of an animal spine, respectively. This work indicates that off-axis reflections are a major source of ultrasound image artifacts, particularly in environments comprising specular reflecting (i.e., bone or bone-like) objects. Transducer geometries with reduced sensitivity to off-axis surface reflections, such as a piston transducer geometry, yield significant reductions in image artifact.

  19. Nicotinic Acetylcholine Receptors Mediate the Suppressive Effect of an Injection of Diluted Bee Venom into the GV3 Acupoint on Oxaliplatin-Induced Neuropathic Cold Allodynia in Rats.

    PubMed

    Yoon, Heera; Kim, Min Joon; Yoon, Insoo; Li, Dong Xing; Bae, Hyunsu; Kim, Sun Kwang

    2015-01-01

    Oxaliplatin, a platinum-based chemotherapy drug, often induces acute neuropathic pain, especially cold allodynia, even after a single administration. Subcutaneous injection of diluted bee venom (BV) into acupoints has been used to treat various pain symptoms in traditional oriental medicine. Although we previously demonstrated the suppressive effect of BV injection on oxaliplatin-induced cold allodynia in rats, its neurochemical mechanism remained unclear. This study investigates whether and how the cholinergic system mediates the relieving effect of BV injection on cold allodynia in oxaliplatin-administered rats. The behavioral signs of cold allodynia induced by an oxaliplatin administration (6 mg/kg, intraperitoneally (i.p.)) were evaluated by a tail immersion test in cold water (4°C). BV (0.25 mg/kg, subcutaneously (s.c.)) injection into the Yaoyangguan acupoint, located between the spinous processes of the fourth and fifth lumbar vertebrae, significantly alleviated the cold allodynia. This relieving effect of BV injection on oxaliplatin-induced cold allodynia was blocked by a pretreatment with mecamylamine (a non-selective nicotinic receptor antagonist, 2 mg/kg, i.p.), but not by atropine (a non-selective muscarinic receptor antagonist, 1 mg/kg, i.p.). Further, dihydro-β-erythroidinehydrobromide (DHβE, an α4β2 nicotinic antagonist, 5 mg/kg, i.p.) prevented the anti-allodynic effect of BV, whereas methyllycaconitine (an α7 nicotinic antagonist, 6 mg/kg, i.p.) did not. Finally, intrathecal administration of DHβE (10 nM) blocked the BV-induced anti-allodynic effect. These results suggest that nicotinic acetylcholine receptors, especially spinal α4β2 receptors, but not muscarinic receptors, mediate the suppressive effect of BV injection on oxaliplatin-induced acute cold allodynia in rats.

  20. Oxygen venous embolism after the use of hydrogen peroxide during lumbar discectomy.

    PubMed

    Despond, O; Fiset, P

    1997-04-01

    The knee-prone position is commonly used for patients undergoing spinal surgery. Venous air embolism in such a position may be produced by the negative venous pressure gradient between the ambient air and the venous plexuses of the spinous process. When hydrogen peroxide is used to cleanse the wound, oxygen is produced. We report a case of suspected oxygen venous embolism during lumbar discectomy in the knee-prone position after use of H2O2. Immediately after irrigation of a discectomy wound with H2O2, a dramatic decrease of the PETCO2, blood pressure and oxygen saturation coincident with ST segment elevation occurred suggesting a coronary gas embolism. Symptomatic treatment was initiated immediately and the patient recovered without any sequelae. Although hydrogen peroxide has an innocuous reputation, cases of accidental ingestion or massive gas embolism after wound irrigation leading to death have been reported. A review of the literature suggests that many of the clinical and physiopathological features of air and oxygen emboli are similar. For both, measures of prevention and treatment of complications are similar. We argue that the use of hydrogen peroxide should be avoided during procedures where the position of the patient (sitting, knee-prone) increases the risk of gas embolism and that hydrogen peroxide is a potentially dangerous solution.

  1. Bilateral arcuate foramen associated with partial defect of the posterior arch of the atlas in a medieval skeleton: case report and review of the literature. Looking backward to go forward.

    PubMed

    Travan, Luciana; Saccheri, Paola; Sabbadini, Gastone; Crivellato, Enrico

    2011-08-01

    We observed a complex atlas (C1) dysmorphism in a human medieval skeleton dug up from the sixth to the seventh century necropolis located in the north-eastern Italy. We analyzed such a dysmorphism in the light of pertinent literature and discussed the functional and clinical implications related to this type of C1 structural malformation. Macroscopical and CT-SCAN examinations of the atlas were carried out. Bone findings consisted of partial aplasia of the posterior arch of the C1 accompanied by a bilateral arcuate foramen. In addition, the spinous processes of C7 and T1 were found to be bifid. Although such abnormalities are supposed to be clinically inconspicuous, yet they may become challenging or even dangerous in the context of trauma. They may even complicate specific diagnostic or surgical procedures. In addition, they may cause a great number of symptoms, ranging from headache and neck pain to loss of postural muscle tone and consciousness, due to the close and complex relationship of bone structures with nerves, blood vessels, muscles, and ligaments. As a result, radiologists, clinicians, surgeons, and chiropractors should consider in their clinical reasoning the possibility that atlas dysmorphisms may occur.

  2. Oral melanoacanthoma and oral melanotic macule: a report of 8 cases, review of the literature, and immunohistochemical analysis.

    PubMed

    Carlos-Bregni, Román; Contreras, Elisa; Netto, Ana Carolina; Mosqueda-Taylor, Adalberto; Vargas, Pablo Agustin; Jorge, Jacks; León, Jorge Esquiche; de Almeida, Oslei Paes

    2007-09-01

    Oral melanoacanthoma (MA) is a rare, benign pigmented lesion, similar to cutaneous MA, characterized by hyperplasia of spinous keratinocytes and dendritic melanocytes. The pathogenesis of oral MA remains uncertain, although its clinical behavior is suggestive of a reactive origin. The most common intraoral sites are the buccal mucosa, lip, palate and gingiva. The average age of presentation is 28 years, mainly in blacks, with a strong female predilection. The oral melanotic macule (MM) is a small, well-circumscribed brown-to-black macule that occurs on the lips and mucous membranes. The etiology is not clear and it may represent a physiologic or reactive process. The average age of presentation is 43 years, with a female predilection. A biopsy is recommended to distinguish these lesions from each other and from other oral melanocytic lesions. We depict four cases each of oral MA and MM, affecting Caucasian and Latin American mestizo patients. The clinicopathological features of these cases reflect its ample spectrum, and to the best of our knowledge, it is the first example of oral MA affecting a Caucasian boy reported in the English literature. Therefore oral MA and MM should be considered in the differential diagnosis of pigmented lesions in the oral mucosa in these populations.

  3. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique

    PubMed Central

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-01-01

    Context: Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. Aim: This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. Settings and Design: NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Materials and Methods: Hangman II and IIA patient are treated with NSA technique. Result: Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. Conclusions: In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated. PMID:24744563

  4. A new technique in the surgical treatment of Hangman's fractures: Neurospinal Academy (NSA) technique.

    PubMed

    Dalbayrak, Sedat; Yaman, Onur; Yılmaz, Mesut

    2013-07-01

    Treatment of Hangman's fractures is still controversial. Hangman's fractures Type II and IIA are usually treated with surgical procedures. This study aims at describing the Neurospinal Academy (NSA) technique as an attempt to achieve an approximation of the fracture line to the axis body, which may be used for Type II and IIA patients with severe displacement and angulation. NSA technique both pars or pedicle screws are placed bicortically to ensure that anterior surface of C2 vertebral body will be crossed 1-2 mm. A rod is prepared in suitable length and curve to connect the two screws. For placing the rod, sufficient amount of bone is resected from the C2 spinous process. C2 vertebral body is pulled back by means of the screws that crossed the anterior surface of C2 vertebral body. Hangman II and IIA patient are treated with NSA technique. Angulated and tilted C2 vertebral body was pulled back and approximated to posterior elements. In Hangman's fractures Type II and IIA with severe vertebral body and pedicle displacement, NSA technique is an effective and reliable treatment alternative for the approximation of posterior elements to the C2 vertebral body, which is tilted, angulated, and dislocated.

  5. Radiologic Assessment of Forward Head Posture and Its Relation to Myofascial Pain Syndrome

    PubMed Central

    Sun, An; Yeo, Han Gyeol; Kim, Tae Uk; Hyun, Jung Keun

    2014-01-01

    Objective To assess head posture using cervical spine X-rays to find out whether forward head posture is related to myofascial pain syndrome (MPS) in neck and shoulder. Methods Eighty-eight participants who were diagnosed with MPS in neck and shoulder were evaluated in this study. Four parameters (distance among head, cervical spines, and shoulder, and cervical angle) were measured from lateral view of cervical spine X-ray. The location and number of trigger points in the neck and shoulder and symptom duration were evaluated for each patient. Results Both horizontal distances between C1 vertebral body and C7 spinous process and between the earhole and C7 vertebral body were negatively correlated with cervical angle reflecting cervical lordosis (p<0.05). Younger patients had significantly (p<0.05) less cervical angle with more forward head posture. There was no relationship between MPS (presence, location, and number of trigger points) and radiologic assessments (distance parameters and the cervical angle). Conclusion Forward head posture and reduced cervical lordosis were seen more in younger patients with spontaneous neck pain. However, these abnormalities did not correlate with the location or the number of MPS. Further studies are needed to delineate the mechanism of neck pain in patients with forward head posture. PMID:25566482

  6. Neuromuscular response amplitude to mechanical stimulation using large-array surface electromyography in participants with and without chronic low back pain.

    PubMed

    Pagé, Isabelle; Nougarou, François; Descarreaux, Martin

    2016-04-01

    The present study aimed to compare the neuromuscular response under various mechanical stimulations of the lumbar spine in participants with and without chronic low back pain (cLBP). Four mechanical stimulations, characterized by forces ranging from 75 to 225N, were delivered using a servo-controlled linear actuator motor to the L3 spinous process of 25 healthy participants and 26 participants with cLBP. Lumbar neuromuscular responses were recorded using 64-electrodes large surface electromyography arrays. Between-group differences in the dose-response relationship (neuromuscular response amplitude according to each force level) were assessed using mixed model ANOVAs. No differences between groups were shown (all p values>.05). A significant linear relationship was observed between forces and neuromuscular response amplitudes (p<.001) indicating an increase in response amplitudes with increasing stimulation force. Responses were observed throughout the lumbar region with highest response amplitudes in the vicinity of the contacted vertebra. The neuromuscular response amplitude triggered by localized lumbar mechanical stimulations does not differ between participants with and without cLBP. Moreover, even though stimulations were delivered at specific spinal segment, a neuromuscular response, although rapidly decreasing, was observed in areas distant from the contact site. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Cervical digit in a child

    PubMed Central

    Tong, Min-Ji; Xiang, Guang-Heng; He, Zi-Li; Xu, Hua-Zi; Tian, Nai-Feng

    2017-01-01

    Abstract Background: A “digit-like” bone is a rare developmental anomaly that is usually seen in the pelvic or thoracic regions. Such an anomaly in the cervical spine is extremely rare and few cases have been reported. We present a patient with an anomalous bone posterior to a cervical vertebra. The patient was admitted to our hospital with a gradually growing hard neck mass and esthetic complaints. Physical examination, radiographs, reconstructed computed tomography, and magnetic resonance imaging revealed a digit-like bone posterior to the cervical spine. The patient was diagnosed with a “cervical digit.” Through a posterior midline approach, the anomalous bone was excised because of its gradually increasing size and esthetic complaints. Results: Intraoperatively, the bony mass was found to have a pseudoarticulation with the spinous process of C5 (the fifth cervical vertebra). The specimen consisted of normal bone and cartilage. The child returned to a normal life postoperatively with no symptoms. There was no recurrence at the 2-year follow-up. Conclusion: A congenital cervical digit is a rare deformity. A detailed clinical workup and advanced imaging examinations are useful for diagnosing such conditions. Esthetic complaints contribute to surgical indications. This is the first cervical digit managed with surgical excision of the anomalous bone and had a favorable outcome. PMID:29390517

  8. The sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm that minimizes computerized tomography.

    PubMed

    Arbuthnot, Mary; Mooney, David P

    2017-01-01

    It is crucial to identify cervical spine injuries while minimizing ionizing radiation. This study analyzes the sensitivity and negative predictive value of a pediatric cervical spine clearance algorithm. We performed a retrospective review of all children <21years old who were admitted following blunt trauma and underwent cervical spine clearance utilizing our institution's cervical spine clearance algorithm over a 10-year period. Age, gender, International Classification of Diseases 9th Edition diagnosis codes, presence or absence of cervical collar on arrival, Injury Severity Score, and type of cervical spine imaging obtained were extracted from the trauma registry and electronic medical record. Descriptive statistics were used and the sensitivity and negative predictive value of the algorithm were calculated. Approximately 125,000 children were evaluated in the Emergency Department and 11,331 were admitted. Of the admitted children, 1023 patients arrived in a cervical collar without advanced cervical spine imaging and were evaluated using the cervical spine clearance algorithm. Algorithm sensitivity was 94.4% and the negative predictive value was 99.9%. There was one missed injury, a spinous process tip fracture in a teenager maintained in a collar. Our algorithm was associated with a low missed injury rate and low CT utilization rate, even in children <3years old. IV. Published by Elsevier Inc.

  9. Boomerang deformity of cervical spinal cord migrating between split laminae after laminoplasty.

    PubMed

    Kimura, S; Gomibuchi, F; Shimoda, H; Ikezawa, Y; Segawa, H; Kaneko, F; Uchiyama, S; Homma, T

    2000-04-01

    Patients with cervical compression myelopathy were studied to elucidate the mechanism underlying boomerang deformity, which results from the migration of the cervical spinal cord between split laminae after laminoplasty with median splitting of the spinous processes (boomerang sign). Thirty-nine cases, comprising 25 patients with cervical spondylotic myelopathy, 8 patients with ossification of the posterior longitudinal ligament, and 6 patients with cervical disc herniation with developmental canal stenosis, were examined. The clinical and radiological findings were retrospectively compared between patients with (B group, 8 cases) and without (C group, 31 cases) boomerang sign. Moderate increase of the grade of this deformity resulted in no clinical recovery, although there was no difference in clinical recovery between the two groups. Most boomerang signs developed at the C4/5 and/or C5/6 level, where maximal posterior movement of the spinal cord was achieved. Widths between lateral hinges and between split laminae in the B group were smaller than in the C group. Flatness of the spinal cord in the B group was more severe than in the C group. In conclusion, the boomerang sign was caused by posterior movement of the spinal cord, narrower enlargement of the spinal canal and flatness of the spinal cord.

  10. Magnetic stimulation of the cauda equina in the spinal canal with a flat, large round coil.

    PubMed

    Matsumoto, Hideyuki; Octaviana, Fitri; Terao, Yasuo; Hanajima, Ritsuko; Yugeta, Akihiro; Hamada, Masashi; Inomata-Terada, Satomi; Nakatani-Enomoto, Setsu; Tsuji, Shoji; Ugawa, Yoshikazu

    2009-09-15

    Magnetic round coil stimulation over the spinal enlargement activates the spinal nerves at the neuro-foramina level. However, activation of the cauda equina in the spinal canal has never been described in the literature. This study, for which 40 healthy subjects were recruited, activated the cauda equina using a round 20-cm-diameter coil designated as a Magnetic Augmented Translumbosacral Stimulation (MATS) coil. Magnetic stimulation placing the edge of the coil over the L1 and L3 spinous processes elicited compound muscle action potentials (CMAPs) from the abductor hallucis muscle. The CMAPs were compared with those elicited through high-voltage electrical stimulation. The CMAP latencies to L1 level MATS coil stimulation were not significantly different from those evoked by electrical stimulation at the same level. The CMAP latencies to L3 level MATS coil stimulation were varied in each subject. In fact, the L1 level MATS coil stimulation is considered to activate the cauda equina at the root exit site from the conus medullaris; the L3 level MATS coil stimulation activates some mid-part of the cauda equina or the distal cauda equina by spreading current. The MATS coil facilitates evaluation of spinal nerve conduction in the cauda equina.

  11. Effect of Different Dosages of ST36 Indirect Moxibustion on the Skin Temperature of the Lower Legs and Feet.

    PubMed

    Kuge, Hiroshi; Mori, Hidetoshi; Morisawa, Tateyuki; Hanyu, Kazuyo; Miyazaki, Junji; Watanabe, Mayumi; Tanaka, Tim Hideaki

    2018-06-15

    Background: Indirect moxibustion (IM) has been previously performed between the spinous process while recording skin temperature of the trunk. However, moxibustion is often applied not only to acupuncture points on the back, but also to points located on the limbs. Thus, there is a need to investigate skin temperature (ST) responses following IM applied to the limbs. Methods: In Experiment 1 (Exp 1), subjects were randomly assigned to three groups: the left IM stimulation, right IM stimulation and control groups. In Experiment 2 (Exp 2), the subjects underwent two experimental sessions consisting of a single stimulation of IM or triple stimulations of IM. The IM stimulation was administered to the ST36 acupuncture point. A thermograph was used to obtain the ST on the lower limbs. Results: In Exp 1, the ST of the lower limbs increased in the stimulation groups whereas there was no increase in the non-stimulation group. In Exp 2, no significant response occurred between the single and triple stimulation of IM groups for all observed sites except for the left ankle ST. Conclusions: Lower limb ST increased following IM application to the ST36 point. No difference was observed between the dosage of the stimulation and ST responses.

  12. Morphology of the lumbar transversospinal muscles examined in a mouse bearing a muscle fiber-specific nuclear marker.

    PubMed

    Cornwall, Jon; Deries, Marianne; Duxson, Marilyn

    2010-12-01

    Although the morphology of human lumbar transversospinal (TSP) muscles has been studied, little is known about the structure of these muscles in the mouse (Mus musculus). Such information is relevant given mice are often used as a "normal" phenotype for studies modeling human development. This study describes the gross morphology, muscle fiber arrangement, and innervation pattern of the mouse lumbar TSP muscles. A unique feature of the study is the use of a transgenic mouse line bearing a muscle-specific nuclear marker that allows clear delineation of muscle fiber and connective tissue boundaries. The lumbar TSP muscles of five mice were examined bilaterally; at each spinal level muscles attached to the caudal edge of the spinous process and passed caudally as a single complex unit. Fibers progressively terminated over the four vertebral segments caudad, with multiple points of muscle fiber attachment on each vertebra. Motor endplates, defined with acetylcholinesterase histochemistry, were consistently located half way along each muscle fiber, regardless of length, with all muscle fibers arranged in-parallel rather than in-series. These results provide information relevant to interpretation of developmental and functional studies involving this muscle group in the mouse and show mouse lumbar TSP muscles are different in form to descriptions of equivalent muscles in humans and horses.

  13. Reliability and validity of gait analysis by android-based smartphone.

    PubMed

    Nishiguchi, Shu; Yamada, Minoru; Nagai, Koutatsu; Mori, Shuhei; Kajiwara, Yuu; Sonoda, Takuya; Yoshimura, Kazuya; Yoshitomi, Hiroyuki; Ito, Hiromu; Okamoto, Kazuya; Ito, Tatsuaki; Muto, Shinyo; Ishihara, Tatsuya; Aoyama, Tomoki

    2012-05-01

    Smartphones are very common devices in daily life that have a built-in tri-axial accelerometer. Similar to previously developed accelerometers, smartphones can be used to assess gait patterns. However, few gait analyses have been performed using smartphones, and their reliability and validity have not been evaluated yet. The purpose of this study was to evaluate the reliability and validity of a smartphone accelerometer. Thirty healthy young adults participated in this study. They walked 20 m at their preferred speeds, and their trunk accelerations were measured using a smartphone and a tri-axial accelerometer that was secured over the L3 spinous process. We developed a gait analysis application and installed it in the smartphone to measure the acceleration. After signal processing, we calculated the gait parameters of each measurement terminal: peak frequency (PF), root mean square (RMS), autocorrelation peak (AC), and coefficient of variance (CV) of the acceleration peak intervals. Remarkable consistency was observed in the test-retest reliability of all the gait parameter results obtained by the smartphone (p<0.001). All the gait parameter results obtained by the smartphone showed statistically significant and considerable correlations with the same parameter results obtained by the tri-axial accelerometer (PF r=0.99, RMS r=0.89, AC r=0.85, CV r=0.82; p<0.01). Our study indicates that the smartphone with gait analysis application used in this study has the capacity to quantify gait parameters with a degree of accuracy that is comparable to that of the tri-axial accelerometer.

  14. Additive-manufactured patient-specific titanium templates for thoracic pedicle screw placement: novel design with reduced contact area.

    PubMed

    Takemoto, Mitsuru; Fujibayashi, Shunsuke; Ota, Eigo; Otsuki, Bungo; Kimura, Hiroaki; Sakamoto, Takeshi; Kawai, Toshiyuki; Futami, Tohru; Sasaki, Kiyoyuki; Matsushita, Tomiharu; Nakamura, Takashi; Neo, Masashi; Matsuda, Shuich

    2016-06-01

    Image-based navigational patient-specific templates (PSTs) for pedicle screw (PS) placement have been described. With recent advances in three-dimensional computer-aided designs and additive manufacturing technology, various PST designs have been reported, although the template designs were not optimized. We have developed a novel PST design that reduces the contact area without sacrificing stability. It avoids susceptibility to intervening soft tissue, template geometric inaccuracy, and difficulty during template fitting. Fourteen candidate locations on the posterior aspect of the vertebra were evaluated. Among them, locations that had high reproducibility on computed tomography (CT) images and facilitated accurate PS placement were selected for the final PST design. An additive manufacturing machine (EOSINT M270) fabricated the PSTs using commercially pure titanium powder. For the clinical study, 36 scoliosis patients and 4 patients with ossification of the posterior longitudinal ligament (OPLL) were treated with thoracic PSs using our newly developed PSTs. We intraoperatively and postoperatively evaluated the accuracy of the PS hole created by the PST. Based on the segmentation reproducibility and stability analyses, we selected seven small, round contact points for our PST: bilateral superior and inferior points on the transverse process base, bilateral inferior points on the laminar, and a superior point on the spinous process. Clinically, the success rates of PS placement using this PST design were 98.6 % (414/420) for scoliosis patients and 100 % (46/46) for OPLL patients. This study provides a useful design concept for the development and introduction of patient-specific navigational templates for placing PSs.

  15. [Skin changes in albinism in persons of the Negroid race (light- and electron-microscopy studies].

    PubMed

    Semkin, V I; Mikhaĭlov, I N

    1984-01-01

    The skin of the negroid race albinos is studied light- and electron-microscopically. Morphological alterations, as compared to control, consist of the horny layer thickening, increase of the cellularity in the epidermis, appearance of numerous pronounced tonofibrillar-keratohyaline complexes in the granular cells and a well developed network of dense bundles of tonofibrils in the spinous layer. Melanocytes and Langerhans cells are similar by their structure and number to those in the control. The protein skeletons of melanosomes in keratinocytes and melanocytes are practically unchanged but they are completely deprived of melanine biopolymer. The dermal macrophages do not contain a melanin pigment. The morphological features of the albinos epidermis, particularly the horny layer thickening, increase of the cellularity and the presence of pronounced tonofibrillar-keratohyaline complexes represent most likely a compensatory protective mechanism against ultraviolet radiation.

  16. Bilateral symptomatic synovial cysts of the lumbar spine caused by calcium pyrophosphate deposition disease: a case report.

    PubMed

    Gadgil, Anirudh A; Eisenstein, Stephan M; Darby, Alan; Cassar Pullicino, Victor

    2002-10-01

    A case of bilateral symptomatic facet joint synovial cysts arising in association with calcium pyrophosphate deposition disease is reported. To present a previously unreported cause for symptomatic synovial cysts of the lumbar spine. Synovial cysts of the facet joints occur most commonly in association with degenerative disease of the spine in older individuals. The association of these cysts with trauma, rheumatoid arthritis, spondylolysis, and kissing spinous processes also has been reported. These cysts can cause symptoms and signs from direct compression of the dura. Chondrocalcinosis has not been previously reported to cause symptomatic synovial cysts. A 67-year-old woman presented with right lower limb sciatica caused by a right L4-L5 facet joint cyst, which resolved after surgical decompression. A year later, she presented with left lower limb sciatica caused by development of a new L4-L5 facet joint cyst, which also resolved after surgical decompression. Histopathologic examination of each cyst showed a cyst wall of fibrous tissue with synovial lining, inflammation, and granulation tissue. Examination of the tissue under polarized light showed positively birefringent, short blunt crystals of calcium pyrophosphate dihydrate. In patients with a history of gout or pseudogout, a rare possibility of a synovial cyst should be considered in the differential diagnosis during investigation for the cause of neural compression resulting in sciatic syndrome.

  17. Changes in Vertebral Column Height (VCH) at Different Distance Intervals During a 3-Mile Walk.

    PubMed

    Roush, J R; Kee, M; Toeppe, J

    2008-08-01

    The purpose of this study was to determine the changes in vertebral column height (VCH) of males and females, at every one-half mile, for a total walking distance of 3 miles. Twenty males and twenty females between the ages of 21 and 40 years walked 3 miles on a treadmill maintaining a walking speed that the subject rated between 12 and 14 on Borg's rate of perceived exertion scale. Blood pressure, heart rate, and VCH measurements were taken initially and at each half-mile interval throughout the three-mile walk. Vertebral column height (VCH) was measured from the spinous process of C7 to S2 using a standard tape measure. Significant differences existed in vertebral column height according to sex (F = 16.18; p < .05) and significant differences in vertebral column height at the different distances (F = 65.02: p < .0001). Significant changes occurred in the VCH between half-mile intervals only between 0.5 miles and 1.0 mile and between 1.0 mile and 1.5 miles during the walk. As found with a regression analysis, curvilinear relationship exists between the distance walked and VCH; with VCH decreasing throughout the distance of the walk. Vertebral column height decreased in a curvilinear relationship throughout the distance of walking 3 miles in both males and females.

  18. Changes in Vertebral Column Height (VCH) at Different Distance Intervals During a 3-Mile Walk

    PubMed Central

    Kee, M; Toeppe, J

    2008-01-01

    Background The purpose of this study was to determine the changes in vertebral column height (VCH) of males and females, at every one-half mile, for a total walking distance of 3 miles. Methods Twenty males and twenty females between the ages of 21 and 40 years walked 3 miles on a treadmill maintaining a walking speed that the subject rated between 12 and 14 on Borg's rate of perceived exertion scale. Blood pressure, heart rate, and VCH measurements were taken initially and at each half-mile interval throughout the three-mile walk. Vertebral column height (VCH) was measured from the spinous process of C7 to S2 using a standard tape measure. Results Significant differences existed in vertebral column height according to sex (F = 16.18; p < .05) and significant differences in vertebral column height at the different distances (F = 65.02: p < .0001). Significant changes occurred in the VCH between half-mile intervals only between 0.5 miles and 1.0 mile and between 1.0 mile and 1.5 miles during the walk. As found with a regression analysis, curvilinear relationship exists between the distance walked and VCH; with VCH decreasing throughout the distance of the walk. Conclusions Vertebral column height decreased in a curvilinear relationship throughout the distance of walking 3 miles in both males and females. PMID:21509126

  19. Factors Associated with Blunt Cerebrovascular Injury in Patients with Cervical Spine Injury

    PubMed Central

    NAKAJIMA, Hiroyuki; NEMOTO, Manabu; TORIO, Tetsuya; TAKEDA, Ririko; OOIGAWA, Hidetoshi; ARAKI, Ryuichiro; KURITA, Hiroki

    2014-01-01

    Blunt cerebrovascular injury (BCVI) is known to be a potentially fatal complication of cervical spine injury (CSI). Methods for screening the appropriate population remain to be elucidated, especially in Japan. This retrospective study was conducted to predict the risk factors relevant to BCVIs. Among 92 patients with CSI transferred to our institution from April 2007 to March 2012, 40 patients (35 men, 5 women) with neurological deficits and/or significant cervical spine fracture including fracture of transversarium, facet, body, lamina, and spinous process, underwent multi-detector computed tomography angiography (MDCTA) and magnetic resonance angiography (MRA), which identified 10 patients with BCVI [2 carotid artery injuries (BCAIs) and 9 vertebral artery injuries (BVAIs); 1 patient suffered both]. Univariate analyses exploring associations between individual risk factors and BCVI and BVAI were performed using Fisher's exact test and Chi-square test for dichotomous variables and the unpaired t-test for continuous variables. Multiple logistic regression analyses for BCVI and BVAI were carried out using stepwise methods. On univariate and multivariate analysis, hyperextension injury was significantly associated with BVAI (p = 0.01 and p = 0.02), and subluxation (dislocation of vertebral body > 5 mm) was a significant predictor of BCVI (p = 0.04 and p = 0.03) and BVAI (p = 0.01 and p = 0.01). Prompt evaluation for BCVIs is recommended in CSI patients with hyperextension injury and dislocation of the vertebral body. PMID:24390186

  20. Management of irreducible unilateral facet joint dislocations in subaxial cervical spine: two case reports and a review of the literature.

    PubMed

    Zhou, Yu; Zhou, Zhenyu; Liu, Lifeng; Cao, Xuecheng

    2018-03-21

    Skeletal and soft tissue damage are often associated with unilateral facet dislocations, which undoubtedly lead to instability of the spine and further increase difficulties in cervical reduction. This type of irreducible facet dislocation is usually accompanied with potential catastrophic consequences including neurological deficit and severe disability. Therefore, a consistent and evidence-based treatment plan is imperative. The literature regarding the management of traumatic unilateral locked cervical facet dislocations was reviewed. Two patient cases (a 30-year-old Asian man and a 25-year-old Asian woman) who suffered irreducible cervical facet dislocations were presented. These two patients received surgical treatments including posterior reduction by poking facet joints, adjacent spinous process fixation by wire rope banding, anterior plate fixation, and intervertebral fusion after the failure of skull traction and closed reduction. At the postoperative 24-month follow-up, intervertebral fusion was achieved and our patients' neurological status improved based on the American Spinal Injury Association scale, compared with their preoperative status. Unilateral facet joint dislocations of subaxial cervical spine are difficult to reduce when complicated with posterior facet fractures or ligamentous injury. Magnetic resonance imaging can be beneficial for identifying ventral and dorsal compressive lesions, as well as ligamentous or capsule rupture. The combination of posterior reduction and anterior fixation with fusion has advantages in terms of clinical safety, ease of operation, and less iatrogenic damage.

  1. Cervical Fracture With Transient Tetraplegia in a Youth Football Player: Case Report and Review of the Literature

    PubMed Central

    Molinari, Robert; Molinari, William J

    2010-01-01

    Background/Objective: Serious cervical spinal injuries in organized youth football are rare. Cervical fracture with neurologic injury is rarely reported in organized youth football players with no pre-existing risk fractures for transient tetraplegia. Methods: Case report and literature review. Results: After being improperly tackled by an opponent of significantly larger body size, a player sustained a C7 posterior cervical fracture with transient tetraplegia. He was immobilized in a cervical collar and sent to a level 1 trauma center for evaluation. Initial examination showed bilateral paresthesia of the limbs with normal motor function (ASIA D). Initial radiographs of the cervical spine showed a displaced extension-compression fracture of the C7 spinous process. Magnetic resonance imaging of the cervical spine showed edema in the spinal cord in the region of the injury along with significant posterior injury. Imaging studies showed normal volumetric measurements of the spinal canal and no pre-existing risk factors for spinal stenosis or spinal cord injury. Radiographs showed that cervical fracture was healed at 9-month follow-up examination. At 1-year follow-up, the patient was asymptomatic. Radiographs showed healed fracture with no residual instability and full range of cervical spine motion on flexion–extension views. Conclusions: This case underscores the potential for serious cervical spinal injuries in organized youth sports when players are physically overmatched, and improper tackling technique is used. PMID:20486536

  2. Electromyographic analyses of the erector spinae muscles during golf swings using four different clubs.

    PubMed

    Sorbie, Graeme G; Grace, Fergal M; Gu, Yaodong; Baker, Julien S; Ugbolue, Ukadike C

    2018-04-01

    The purpose of this study was to compare the electromyography (EMG) patterns of the thoracic and lumbar regions of the erector spinae (ES) muscle during the golf swing whilst using four different golf clubs. Fifteen right-handed male golfers performed a total of twenty swings in random order using the driver, 4-iron, 7-iron and pitching-wedge. Surface EMG was recorded from the lead and trail sides of the thoracic and lumbar regions of the ES muscle (T8, L1 and L5 lateral to the spinous-process). Three-dimensional high-speed video analysis was used to identify the backswing, forward swing, acceleration, early and late follow-through phases of the golf swing. No significant differences in muscle-activation levels from the lead and trail sides of the thoracic and lumbar regions of the ES muscle were displayed between the driver, 4-iron, 7-iron and pitching-wedge (P > 0.05). The highest mean thoracic and lumbar ES muscle-activation levels were displayed in the forward swing (67-99% MVC) and acceleration (83-106% MVC) phases of the swing for all clubs tested. The findings from this study show that there were no significant statistical differences between the driver, 4-iron, 7-iron and pitching-wedge when examining muscle activity from the thoracic and lumbar regions of the ES muscle.

  3. Cadaveric and Ultrasonographic Validation of Needling Placement in the Cervical Multifidus Muscle.

    PubMed

    Fernández-de-Las-Peñas, César; Mesa-Jiménez, Juan A; Paredes-Mancilla, Jose A; Koppenhaver, Shane L; Fernández-Carnero, Samuel

    2017-06-01

    The aim of this study was to determine if a needle is able to reach the cervical multifidus during the application of dry needling or acupuncture. Dry needling and ultrasound imaging of cervical multifidi was conducted on 5 patients (age: 32 ± 5 years) with mechanical neck pain and on 2 fresh cadavers (age: 64 ± 1 years). Dry needling was done using a needle of 40 mm in length inserted perpendicular to the skin about 1 cm lateral to the spinous process at C3-C4. The needle was advanced from a posterior to anterior direction into the cervical multifidus with a slight inferior-medial angle (approximately 10°) to reach the vertebra lamina. For the cadaveric study, the multifidus was isolated by carefully resecting the superficial posterior cervical muscles: trapezius, splenius, and semispinalis. For the ultrasonographic study, a convex transducer was placed transversely over C3-C4 after the insertion of the needle into the muscle. The results of both the cadaveric and ultrasonic studies found that the needle does pierce the cervical multifidus muscle during insertion and that the tip of the needle rests properly against the vertebral laminae, thereby guarding the sensitive underlying spinal structures from damage. This anatomical and ultrasound imaging study supports that dry needling of the cervical multifidus could be conducted clinically. Copyright © 2017. Published by Elsevier Inc.

  4. Feed Additives Production Out of Dairy Industry Waste

    NASA Astrophysics Data System (ADS)

    Ulrikh, EV

    2017-05-01

    Application of macro- and microelements in animal feed is the most effective in the case of their industrial brining in mixed feeds, feed mixes, and protein-vitamin supplements in the form of various complex salts. Application of the product contributes to the body’s needs of broiler chickens in vitamins and minerals, normalization of metabolism, and ensures a high rate of growth and development. The composition of the premix can be adjusted depending on the actual proportion of biologically active substances in the feed used by a consumer. It is possible to include in the premix other biologically active substances. Assessing the slaughter qualities of experimental pigs, it was found (Table. 2) that the pigs of group II has a tendency toward greater weight of hot carcass (4.5 kg), of slaughter yelts (by 3.83%) and toward a smaller thickness of fat over the spinous processes of the 6-7th thoracic vertebrae (1.67 mm). The performed investigations have established that there is no significant difference between groups I and II in the content of certain amino acids, however, group I shows poorer results in the content of valine, isoleucine, leucine and lysine by 0.16 g / 100 g of protein (P> 0.999) 0.2 (P> 0.90), 0.46 (P> 0.999) and 0.39 (P> 0.999) g / 100 g protein respectively.

  5. Surface EMG of shoulder and back muscles and posture analysis in secretaries typing at visual display units.

    PubMed

    Kleine, B U; Schumann, N P; Bradl, I; Grieshaber, R; Scholle, H C

    1999-09-01

    A study was carried out to investigate temporal changes of activation of shoulder and back muscles in workers at visual display units by means of surface EMG. Moreover, postural parameters were recorded to distinguish fatigue-related from posture-related changes of the myoelectrical activity. Nine healthy female office workers typed texts spoken from tape during three 1-h-long sessions. After the first and again after the second hour there was a break of 15 min. Sixteen-channel surface EMG was bipolarly recorded from the erector spinae, trapezius, deltoid and sternocleidomastoid muscles. Root mean square (RMS) and power spectrum median frequency of the EMG were calculated. Sitting posture was assessed using an eight-channel movement analysis system with ultrasound markers. The position of the seventh cervical spinous process and the left and the right acromion were analysed synchronously with the EMG characteristics using regression analysis. The normalised RMS of the left and right trapezius muscle increased, while the median frequency did not change. The increase of the normalised RMS was significantly lower when the linear influence of posture was excluded. On average, the distance between C7 and the left and right acromion decreased within each working an hour. C7 became lower on average by 5.5 mm within an hour, whereas the acromions became lower by only 1.7 mm (left) and 3.3 mm (right). The increase in trapezius muscle activity was partly related to a lifting of the shoulders to compensate a slight slumping of the back. Another part of the EMG activity increase has to be attributed to fatigue, to attention-related activity or to the combination of both. Therefore, training of the back muscles and a varied organisation of work might have a preventive effect with respect to musculoskeletal complaints in VDU workers.

  6. Body Position Influences Which Neural Structures Are Recruited by Lumbar Transcutaneous Spinal Cord Stimulation

    PubMed Central

    Danner, Simon M.; Krenn, Matthias; Hofstoetter, Ursula S.; Toth, Andrea; Mayr, Winfried; Minassian, Karen

    2016-01-01

    Transcutaneous stimulation of the human lumbosacral spinal cord is used to evoke spinal reflexes and to neuromodulate altered sensorimotor function following spinal cord injury. Both applications require the reliable stimulation of afferent posterior root fibers. Yet under certain circumstances, efferent anterior root fibers can be co-activated. We hypothesized that body position influences the preferential stimulation of sensory or motor fibers. Stimulus-triggered responses to transcutaneous spinal cord stimulation were recorded using surface-electromyography from quadriceps, hamstrings, tibialis anterior, and triceps surae muscles in 10 individuals with intact nervous systems in the supine, standing and prone positions. Single and paired (30-ms inter-stimulus intervals) biphasic stimulation pulses were applied through surface electrodes placed on the skin between the T11 and T12 inter-spinous processes referenced to electrodes on the abdomen. The paired stimulation was applied to evaluate the origin of the evoked electromyographic response; trans-synaptic responses would be suppressed whereas direct efferent responses would almost retain their amplitude. We found that responses to the second stimulus were decreased to 14%±5% of the amplitude of the response to the initial pulse in the supine position across muscles, to 30%±5% in the standing, and to only 80%±5% in the prone position. Response thresholds were lowest during standing and highest in the prone position and response amplitudes were largest in the supine and smallest in the prone position. The responses obtained in the supine and standing positions likely resulted from selective stimulation of sensory fibers while concomitant motor-fiber stimulation occurred in the prone position. We assume that changes of root-fiber paths within the generated electric field when in the prone position increase the stimulation thresholds of posterior above those of anterior root fibers. Thus, we recommend conducting spinal reflex or neuromodulation studies with subjects lying supine or in an upright position, as in standing or stepping. PMID:26797502

  7. Comparative sacral morphology and the reconstructed tail lengths of five extinct primates: Proconsul heseloni, Epipliopithecus vindobonensis, Archaeolemur edwardsi, Megaladapis grandidieri, and Palaeopropithecus kelyus.

    PubMed

    Russo, Gabrielle A

    2016-01-01

    This study evaluated the relationship between the morphology of the sacrum-the sole bony link between the tail or coccyx and the rest of the body-and tail length (including presence/absence) and function using a comparative sample of extant mammals spanning six orders (Primates, Carnivora, Rodentia, Diprotodontia, Pilosa, Scandentia; N = 472). Phylogenetically-informed regression methods were used to assess how tail length varied with respect to 11 external and internal (i.e., trabecular) bony sacral variables with known or suspected biomechanical significance across all mammals, only primates, and only non-primates. Sacral variables were also evaluated for primates assigned to tail categories ('tailless,' 'nonprehensile short-tailed,' 'nonprehensile long-tailed,' and 'prehensile-tailed'). Compared to primates with reduced tail lengths, primates with longer tails generally exhibited sacra having larger caudal neural openings than cranial neural openings, and last sacral vertebrae with more mediolaterally-expanded caudal articular surfaces than cranial articular surfaces, more laterally-expanded transverse processes, more dorsally-projecting spinous processes, and larger caudal articular surface areas. Observations were corroborated by the comparative sample, which showed that shorter-tailed (e.g., Lynx rufus [bobcat]) and longer-tailed (e.g., Acinonyx jubatus [cheetah]) non-primate mammals morphologically converge with shorter-tailed (e.g., Macaca nemestrina) and longer-tailed (e.g., Macaca fascicularis) primates, respectively. 'Prehensile-tailed' primates exhibited last sacral vertebrae with more laterally-expanded transverse processes and greater caudal articular surface areas than 'nonprehensile long-tailed' primates. Internal sacral variables performed poorly compared to external sacral variables in analyses of extant primates, and were thus deemed less useful for making inferences concerning tail length and function in extinct primates. The tails lengths of five extinct primates were reconstructed from the external sacral variables: Archaeolemur edwardsi had a 'nonprehensile long tail,' Megaladapis grandidieri, Palaeopropithecus kelyus, and Epipliopithecus vindobonensis probably had 'nonprehensile short tails,' and Proconsul heseloni was 'tailless.' Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Interexaminer reliability of the electromagnetic radiation receiver for determining lumbar spinal joint dysfunction in subjects with low back pain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gemmell, H.A.; Jacobson, B.H.; Edwards, S.W.

    Twenty subjects (6 male, 14 female) with low back pain were examined by two experienced and licensed chiropractic doctors (E1 and E2). Both examiners examined the patients using a Toftness Electromagnetic Radiation Receiver (EMRR) and by manual palpation (MP) of the spinous processes. Interexaminer reliability was calculated at three sites (L3, L4, L5) for the following combinations: (a) E1,MP--E2,MP; (b) E1,EMRR--E2,EMRR; (c) E1,MP--E2,EMRR; and (d) E2,MP--E1,EMRR, and intraexaminer reliability was calculated for the following variables: (e) E1,MP--E1,EMRR; and (f) E2,MP--E2,EMRR. Results of a Kappa coefficient analysis for interexaminer reliability of the stated combinations and at the specific sites were: (a)more » -0.071, 0.400, 0.200; (b) -0.013, 0.100, -0.120; (c) 0.286, 0.300, 0.200; (d) -0.081, 0.000, 0.048. These results predominantly indicate a poor to fair interexaminer reliability. The results of a Kappa coefficient analysis for intraexaminer reliability of the stated combinations were: (e) 0.111, 0.400, 0.737; (f) 0.000, 0.100, 0.368. These results indicate a poor to fair reliability. It was concluded that in subjects with low back pain the EMRR may not be a reliable indicator of spinal joint dysfunction.« less

  9. Functional morphology of the primate head and neck.

    PubMed

    Nalley, Thierra K; Grider-Potter, Neysa

    2015-04-01

    The vertebral column plays a key role in maintaining posture, locomotion, and transmitting loads between body components. Cervical vertebrae act as a bridge between the torso and head and play a crucial role in the maintenance of head position and the visual field. Despite its importance in positional behaviors, the functional morphology of the cervical region remains poorly understood, particularly in comparison to the thoracic and lumbar sections of the spinal column. This study tests whether morphological variation in the primate cervical vertebrae correlates with differences in postural behavior. Phylogenetic generalized least-squares analyses were performed on a taxonomically broad sample of 26 extant primate taxa to test the link between vertebral morphology and posture. Kinematic data on primate head and neck postures were used instead of behavioral categories in an effort to provide a more direct analysis of our functional hypothesis. Results provide evidence for a function-form link between cervical vertebral shape and postural behaviors. Specifically, taxa with more pronograde heads and necks and less kyphotic orbits exhibit cervical vertebrae with longer spinous processes, indicating increased mechanical advantage for deep nuchal musculature, and craniocaudally longer vertebral bodies and more coronally oriented zygapophyseal articular facets, suggesting an emphasis on curve formation and maintenance within the cervical lordosis, coupled with a greater resistance to translation and ventral displacement. These results not only document support for functional relationships in cervical vertebrae features across a wide range of primate taxa, but highlight the utility of quantitative behavioral data in functional investigations. © 2015 Wiley Periodicals, Inc.

  10. Design of mulitlevel OLF approach ("V"-shaped decompressive laminoplasty) based on 3D printing technology.

    PubMed

    Ling, Qinjie; He, Erxing; Ouyang, Hanbin; Guo, Jing; Yin, Zhixun; Huang, Wenhua

    2017-07-27

    To introduce a new surgical approach to the multilevel ossification of the ligamentum flavum (OLF) aided by three-dimensional (3D) printing technology. A multilevel OLF patient (male, 66 years) was scanned using computed tomography (CT). His saved DICOM format data were inputted to the Mimics14.0 3D reconstruction software (Materialise, Belgium). The resulting 3D model was used to observe the anatomical features of the multilevel OLF area and to design the surgical approach. At the base of the spinous process, two channels were created using an osteotomy bilaterally to create a "V" shape to remove the bone ligamentous complex (BLC). The decompressive laminoplasty using mini-plate fixation was simulated with the computer. The physical model was manufactured using 3D printing technology. The patient was subsequently treated using the designed surgery. The operation was completed successfully without any complications. The operative time was 90 min, and blood loss was 200 ml. One month after the operation, neurologic function was recovered well, and the JOA score was improved from 6 preoperatively to 10. Postoperative CT scanning showed that the OLF was totally removed, and the replanted BLC had not subsided. 3D printing technology is an effective, reliable, and minimally invasive method to design operations. The technique can be an option for multilevel OLF surgical treatment. This can provide sufficient decompression with minimum damage to the spine and other intact anatomical structures.

  11. Eradication of damaged keratinocytes in cutaneous lichen planus forms demonstrated by evaluation of epidermal and follicular expression of CK15, indices of apoptosis and regulatory protein S100.

    PubMed

    Upeniece, Ilze; Groma, Valerie; Skuja, Sandra; Cauce, Vinita

    The study of cytoskeleton arrangement and its contribution to survival of cell-to-cell contacts appears to be essential for understanding of numerous cellular and tissue processes. Applying CK15, S100 labeling and TUNEL reaction to cutaneous lichen planus subtypes, we found CK15 expression in the outer and inner root sheath of hair follicles, the basal epidermal layer, and eccrine glands. Its follicular expression was decreased in nearby inflammatory infiltrates. The CK15 immunopositivity was mostly described as weak (92.3%) for lichen planus but equally subdivided into weak, moderate and strong in lichen planopilaris (2 = 32.514; df = 4; p < 0.001). The greatly varying apoptotic index was the highest in the lichen planopilaris involving the scalp: 81.2 ±10.7; 87.8 ±10.7 and 88.0 ±10.5 for the basal, spinous and upper epidermal layers, respectively. S100 positive epidermal and follicular cells did not differ in the lesions demonstrated in the study groups; still immunoreactivity was more pronounced in the scalp region of lichen planopilaris. Damage of cell-to-cell contacts was confirmed by electron microscopy. Apart from immunocyte-mediated keratinocyte death, cytoskeleton-based injury and loss of cell-to-cell and matrix contacts may be of great importance, leading to eradication of degrading cells and thus contributing to the pathogenesis of lichen planus.

  12. Occipitocervical fusions in children. Retrospective analysis and technical considerations.

    PubMed

    Rodgers, W B; Coran, D L; Emans, J B; Hresko, M T; Hall, J E

    1999-07-01

    This report presents a retrospective analysis of the authors' experience with occipitocervical fusions in children and adolescents during the last 2 decades. A description of an operative technique devised by the senior author (JEH), and a comparison of the results using this and other methods of fusion are given. Twenty-three patients underwent occipitocervical fusion. Fifteen of the patients were operated on using the authors' technique. To achieve stable fixation of the distal cervical vertebra a threaded Kirschner wire was passed transversely through the spinous process; occipital fixation was achieved by the traditional method of wiring corticocancellous bone graft to the skull through burr holes. The occipital wires then were wrapped around the Kirschner wire and the graft was cradled in the resulting nest. Halo immobilization was used in 10 patients for an average of 12.5 weeks (range, 6-24 weeks). Twenty-two patients achieved successful fusion at an average followup of 5.8 years (range, 1-14.33 years). Several complications, including transient quadriplegia in one patient, pseudarthrosis in two (one of which persists), hardware fixation failure in one, unintended distal extension of the fusion, pneumonia, wound infection, halo pin infection, skin breakdown under the halo vest, hydrocephalus, cerebrospinal fluid leak, and traumatic fusion fracture were encountered. Results using the technique described herein are comparable with or better than the results reported in the previous literature, and the results of the patients in this series in whom the technique was not used.

  13. P14.06 Central nervous system symptoms as the first manifestation of malignant neoplasm

    PubMed Central

    Espírito Santo, V.; Almendra, R.; Mendes, M.; Veiga, A.; Velon, A.; Guimarães, P.

    2017-01-01

    Abstract Introduction: Neurological involvement is a frequent complication of systemic neoplasm, but not all secondary lesions have clinical manifestations, and there are fewer cases in which first symptom is neurological. Materials and Methods: Retrospective study between January 2006 through November 2016 of patients in whom neurological manifestations due to metastases were the inaugural manifestation of systemic neoplasm. Results: Twenty-six patients (19 male, 7 female) between the ages of 48 and 85 were identified. The main complaints were motor deficit (n = 10), headache (n = 7), behaviour change (n = 3), sensory deficit (n = 2), language disorder (n=1), visual disorder (n=1), syncope (n = 1) and dizziness (n = 1), with 11 patients presenting with symptoms other than the main complaint. Twenty-four patients had brain metastases, in 9 patients, it was solitary, in 5 patients, 2 lesions were found and in the remaining 9, 3 or more lesions were found. Two patients had multiple spinal metastases and 1 patient presented meningeal carcinomatosis. The primary neoplasm were of pulmonary origin (n = 17), gastric (n = 1), prostatic (n = 1), rectal (n = 1) and skin (n=1). In 5 patients the primary lesion remained hidden. Histology results were available in 19 patients: adenocarcinoma (n = 13), small cell carcinoma (n = 3), spinous cell carcinoma (n = 1), melanoma (n = 1) and linitis plastica (n=1). The treatment consisted in corticosteroid treatment (n = 23), chemotherapy (n = 11), radiotherapy (n = 11), surgery (n = 2) and hormonal treatment (n = 1). The mean survival was 225 days, ranging from 9 to 801 days. Conclusions: With this work we verified a broad spectrum of central nervous system symptoms as clinical presentation of malignant neoplasm. In these cases, a detailed investigation is essential for the treatment and prognosis of these patients.

  14. Microscopic investigation to determine the effect of Beauveria bassiana (Bals.) Vuill. and Cymbopogon citratus (DC.) Stapf. treatment on different life stages of Musca domestica (L.).

    PubMed

    Mishra, Sapna; Kumar, Peeyush; Malik, Anushree

    2017-06-01

    Microscopic investigation was done to determine the effect of entomopathogenic fungi, Beauveria bassiana and essential oil of Cymbopogon citratus on different life stages of Musca domestica . Scanning electron microscopy investigation of fungal infected larvae showed sluggish movement, rigor, and failure of body to balance in water. Treated larvae also revealed varied level of cuticle shrinkage and extreme dehydration. Surface of B. bassiana infected pupae showed varied stage of mycelial growth, while the cadaver of adult fly was observed to have extensive fungal growth covering their entire body surface. The application of C. citratus oils on M. domestica larvae resulted in skin shrinkage, spinous cells proliferation and bleb formation, while the treated pupae showed high incidence of incomplete emergence and malformation in emerged adult flies. The current study establishes effect of C. citratus essential oil and B. bassiana infection on different life stages of M. domestica .

  15. Clinical Value of FDG-PET/CT for the Evaluation of Rheumatic Diseases: Rheumatoid Arthritis, Polymyalgia Rheumatica, and Relapsing Polychondritis.

    PubMed

    Kubota, Kazuo; Yamashita, Hiroyuki; Mimori, Akio

    2017-07-01

    FDG is a tracer for visualizing glucose metabolism. PET/CT using FDG is widely used for the diagnosis of cancer, because glycolysis is elevated in cancer cells. Similarly, active inflammatory tissue also exhibits elevated glucose metabolism because of glycolysis in activated macrophages and proliferating fibroblasts. Elevated FDG uptake by active inflammatory tissues, such as those affected by arthritis, vasculitis, lymphadenitis, and chondritis, has enabled the diagnosis of inflammatory diseases using FDG-PET/CT. Rheumatoid arthritis (RA) is a systemic, chronic inflammation of the joints resulting in synovitis. Several clinical studies of RA have demonstrated that FDG uptake in affected joints reflects the disease activity of RA, with strong correlations between FDG uptake and various clinical parameters having been noted. Furthermore, the use of FDG-PET for the sensitive detection and early monitoring of the response to RA therapy has been reported. RA is sometimes associated with subclinical vasculitis, which is related to systemic inflammation. FDG-PET/CT can be used to evaluate subclinical vasculitis in the aorta or carotid artery. Polymyalgia rheumatica (PMR) is an autoimmune musculoskeletal disease of unknown etiology characterized by pain and stiffness in the shoulder, neck, and pelvic girdle, but not in the small finger joints in the hands, together with fever, fatigue, and weight loss. There is no specific test for PMR, and its diagnosis is based on clinical diagnostic criteria and the exclusion of other diseases with similar symptoms. However, FDG-PET/CT reveals a characteristic FDG uptake by the bursitis in ischial tuberosity, greater trochanter, lumbar or cervical spinous process, and scapulohumeral joint. A combination of FDG-PET/CT findings showed a high diagnostic value for PMR in a differential diagnosis from RA. FDG-PET/CT is also very useful for evaluating large vessel vasculitis, which is often associated with PMR. Relapsing polychondritis is a rare multisystem disease of unknown etiology involving cartilaginous and proteoglycan-rich structures. Its rarity and diversity of symptoms often result in a delayed diagnosis. FDG-PET/CT reveals unique FDG uptake findings for chondritis in the auricular, nasal, trachea, bronchial tree, and costal cartilage and in the cartilage of joints. Thus, the spread of knowledge regarding these very specific FDG-PET/CT findings could promote the early diagnosis and improved disease control of relapsing polychondritis. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. α-Synuclein inclusions in the skin of Parkinson's disease and parkinsonism.

    PubMed

    Rodríguez-Leyva, Ildefonso; Calderón-Garcidueñas, Ana Laura; Jiménez-Capdeville, María E; Rentería-Palomo, Ana Arely; Hernandez-Rodriguez, Héctor Gerardo; Valdés-Rodríguez, Rodrigo; Fuentes-Ahumada, Cornelia; Torres-Álvarez, Bertha; Sepúlveda-Saavedra, Julio; Soto-Domínguez, Adolfo; Santoyo, Martha E; Rodriguez-Moreno, José Ildefonso; Castanedo-Cázares, Juan Pablo

    2014-07-01

    The presence in the brain of α-synuclein containing Lewy neurites, or bodies, is the histological hallmark of Parkinson's disease (PD). The discovery of α-synuclein aggregates in nerve endings of the heart, digestive tract, and skin has lent support to the concept of PD as a systemic disease. Our goals were, first, to demonstrate the presence of α-synuclein inclusions in the skin and, second, to detect quantitative differences between patients with PD and atypical parkinsonism (AP). Skin biopsies were taken from 67 patients and 20 controls. The biopsies underwent immunohistochemistry (IHC) and immunofluorescence (IF) testing for α-synuclein, whereupon its presence was quantified as the percentage of positive cells. Patients were divided into those with PD and those with AP. AP patients included AP with neurodegenerative disease (proteinopathies) and secondary AP. Sixty-seven patients (34 with PD) and 20 controls were recruited. In the PD group, α-synuclein was detected in 58% of the cells in the spinous cell layer (SCL), 62% in the pilosebaceous unit (PSU), and 58% in the eccrine glands (EG). The AP-proteinopathies group showed 7%, 7%, and 0% expression of α-synuclein, respectively. No expression was found in the skin of the control group. The expression of α-synuclein in the skin was relatively high in the PD group, scarce in AP, and null for the individuals in the control group. While these findings require further confirmation, this minimally invasive technique may aid in the improvement of the accuracy of PD diagnoses.

  17. Comparative short-term effects of two thoracic spinal manipulation techniques in subjects with chronic mechanical neck pain: a randomized controlled trial.

    PubMed

    Casanova-Méndez, Amaloha; Oliva-Pascual-Vaca, Angel; Rodriguez-Blanco, Cleofás; Heredia-Rizo, Alberto Marcos; Gogorza-Arroitaonandia, Kristobal; Almazán-Campos, Ginés

    2014-08-01

    Spinal Manipulation (SM) has been purported to decrease pain and improve function in subjects with non-specific neck pain. Previous research has investigated which individuals with non-specific neck pain will be more likely to benefit from SM. It has not yet been proven whether or not the effectiveness of thoracic SM depends on the specific technique being used. This double-blind randomized trial has compared the short-term effects of two thoracic SM maneuvers in subjects with chronic non-specific neck pain. Sixty participants were distributed randomly into two groups. One group received the Dog technique (n = 30), with the subject in supine position, and the other group underwent the Toggle-Recoil technique (n = 30), with the participant lying prone, T4 being the targeted area in both cases. Evaluations were made of self-reported neck pain (Visual Analogue Scale); neck mobility (Cervical Range of Motion); and pressure pain threshold at the cervical and thoracic levels (C4 and T4 spinous process) and over the site described for location of tense bands of the upper trapezius muscle. Measurements were taken before intervention, immediately afterward, and 20 min later. Both maneuvers improved neck mobility and mechanosensitivity and reduced pain in the short term. No major or clinical differences were found between the groups. In the between-groups comparison slightly better results were observed in the Toggle-Recoil group only for cervical extension (p = 0.009), right lateral flexion (p = 0.004) and left rotation (p < 0.05). Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Postsacral vertebral morphology in relation to tail length among primates and other mammals.

    PubMed

    Russo, Gabrielle A

    2015-02-01

    Tail reduction/loss independently evolved in a number of mammalian lineages, including hominoid primates. One prerequisite to appropriately contextualizing its occurrence and understanding its significance is the ability to track evolutionary changes in tail length throughout the fossil record. However, to date, the bony correlates of tail length variation among living taxa have not been comprehensively examined. This study quantifies postsacral vertebral morphology among living primates and other mammals known to differ in relative tail length (RTL). Linear and angular measurements with known biomechanical significance were collected on the first, mid-, and transition proximal postsacral vertebrae, and their relationship with RTL was assessed using phylogenetic generalized least-squares regression methods. Compared to shorter-tailed primates, longer-tailed primates possess a greater number of postsacral vertebral features associated with increased proximal tail flexibility (e.g., craniocaudally longer vertebral bodies), increased intervertebral body joint range of motion (e.g., more circularly shaped cranial articular surfaces), and increased leverage of tail musculature (e.g., longer spinous processes). These observations are corroborated by the comparative mammalian sample, which shows that distantly related short-tailed (e.g., Phascolarctos, Lynx) and long-tailed (e.g., Dendrolagus, Acinonyx) nonprimate mammals morphologically converge with short-tailed (e.g., Macaca tonkeana) and long-tailed (e.g., Macaca fascicularis) primates, respectively. Multivariate models demonstrate that the variables examined account for 70% (all mammals) to 94% (only primates) of the variance in RTL. Results of this study may be used to infer the tail lengths of extinct primates and other mammals, thereby improving our understanding about the evolution of tail reduction/loss. © 2014 Wiley Periodicals, Inc.

  19. [Interest of ultrasonographic guidance in paediatric regional anaesthesia].

    PubMed

    Dadure, C; Raux, O; Rochette, A; Capdevila, X

    2009-10-01

    The use of ultrasonographic guidance for regional anaesthesia has known recently a big interest in children in recent years. The linear ultrasound probes with a 25 mm active surface area (or probes with 38 mm active surface area in older children), with high sound frequencies in the range 8-14 MHz, allow a good compromise between excellent resolution for superficial structure and good penetration depths. In children, the easiest ultrasound guided blocks are axillar blocks, femoral blocks, fascia iliaca compartment blocks, ilio-inguinal blocks and para-umbilical blocks, caudal blocks. They permit a safe and easy learning curve of these techniques. The main advantage of ultrasound guided regional anaesthesia is the visualization of different anatomical structures and the approximate localization of the tip of needle. The other advantages for ultrasound guided peripheral nerve blocks in children are: faster onset time of sensory and motor block, longer duration of sensory blockade, increase of blockade quality and reduction of local anesthetic injection. The use of ultrasonographic guidance for central block allows to visualize different structures as well as spine and his content. Spinous process, ligament flavum, dura mater, conus medullaris and cerebrospinal fluid are identifiable, and give some information on spine, epidural space and the depth between epidural space and skin. At last, in caudal block, ultrasounds permit to evaluate the anatomy of caudal epidural space, especially the relation of the sacral hiatus to the dural sac and the search of occult spinal dysraphism. Benefit of this technique is the visualization of targeted nerves or spaces and the spread of injected local anaesthetic.

  20. Posterior Rigid Instrumentation of C7: Surgical Considerations and Biomechanics at the Cervicothoracic Junction. A Review of the Literature.

    PubMed

    Bayoumi, Ahmed B; Efe, Ibrahim E; Berk, Selim; Kasper, Ekkehard M; Toktas, Zafer Orkun; Konya, Deniz

    2018-03-01

    The cervicothoracic junction is a challenging anatomic transition in spine surgery. It is commonly affected by different types of diseases that may significantly impair stability in this region. The seventh cervical vertebra (C7) is an atypical cervical vertebra with unique anatomic features compared to subaxial cervical spine (C3 to C6). C7 has relatively broader laminae, larger pedicles, smaller lateral masses, and a long nonbifid spinous process. These features allow a variety of surgical methods for performing posterior rigid instrumentation in the form of different types of screws, such as lateral mass screws, pedicle screws, transfacet screws, and intralaminar screws. Many biomechanical studies on cadavers have evaluated and compared different types of implants at C7. We reviewed PubMed/Medline by using specific combinations of keywords to summarize previously published articles that examined C7 posterior rigid instrumentation thoroughly in an experimental fashion on patients or cadavers with additional descriptive radiologic parameters for evaluation of the optimum surgical technique for each type. A total of 44 articles were reported, including 22 articles that discussed anatomic considerations (entry points, sagittal and axial trajectories, and features of screws) and another 22 articles that discussed the relevant biomechanical testing at this transitional region if C7 was directly involved in terms of receiving posterior rigid implants. C7 can accommodate different types of screws, which can provide additional benefits and risks based on availability of bony purchase, awareness of surgical technique, biomechanics, and anatomic considerations. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Long constructs in the thoracic and lumbar spine with a minimally invasive technique.

    PubMed

    Roldan, H; Perez-Orribo, L; Spreafico, M; Ginoves-Sierra, M

    2011-04-01

    Literature about long implants used together with a minimally invasive spine surgery (MISS) technique is scarce. Our objective is to contribute our surgical experience in this field and to specifically focus on several technical details. A digitally-dissected canal along the paravertebral muscles was created linking the stab wounds on each side in relation with the pedicles to be cannulated. Screws were inserted following the percutaneous technique. Long rods were modelled, threaded through the extender sleeves along the paravertebral canal and pushed into the screw heads with the reduction forceps. When fusion was needed, the facet complex was decorticated with a drill. To insert a cross-link, a canal between the 2 rods was digitally created and the spinous process was drilled. 8 patients underwent surgery (age range: 25-77 years). Indications were postosteomyelitis kyphosis in 3 patients, bone tumor in 3, and spine fracture in 2. No blood transfusions were necessary during or after surgery. A cross-link was inserted in 2 patients. Posterolateral bone fusion was attempted in 4, but radiologically identifiable in none. In one patient a cantilever manoeuvre was done to correct kyphosis. Mean duration of surgery was 4 h. There were no clinical complications related to the operation or the hardware (mean follow-up of 7.14 months, range: 1-15 months). The application of MISS techniques can be broadened to long spinal constructs to assess fractures, tumors or deformity, especially in elderly or debilitated patients. Nevertheless, posterolateral fusion is still a challenge through these limited exposures. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Are spinal or paraspinal anatomic markers helpful for vertebral numbering and diagnosing lumbosacral transitional vertebrae?

    PubMed

    Tokgoz, Nil; Ucar, Murat; Erdogan, Aylin Billur; Kilic, Koray; Ozcan, Cahide

    2014-01-01

    To evaluate the value of spinal and paraspinal anatomic markers in both the diagnosis of lumbosacral transitional vertebrae (LSTVs) and identification of vertebral levels on lumbar MRI. Lumbar MRI from 1049 adult patients were studied. By comparing with the whole-spine localizer, the diagnostic errors in numbering vertebral segments on lumbar MRI were evaluated. The morphology of S1-2 disc, L5 and S1 body, and lumbar spinous processes (SPs) were evaluated by using sagittal MRI. The positions of right renal artery (RRA), superior mesenteric artery, aortic bifurcation (AB) and conus medullaris (CM) were described. The diagnostic error for evaluation of vertebral segmentation on lumbar MRI alone was 14.1%. In lumbarization, all patients revealed a well-formed S1-2 disc with squared S1 body. A rhombus-shaped L5 body in sacralization and a rectangular-shaped S1 body in lumbarization were found. The L3 had the longest SP. The most common sites of spinal and paraspinal structures were: RRA at L1 body (53.6%) and L1-2 disc (34.1%), superior mesenteric artery at L1 body (55.1%) and T12-L1 disc (31.6%), and AB at L4 body (71.1%). CM had variable locations, changing from the T12-L1 disc to L2 body. They were located at higher sacralization and lower lumbarization. The spinal morphologic features and locations of the spinal and paraspinal structures on lumbar MRI are not completely reliable for the diagnosis of LSTVs and identification on the vertebral levels.

  3. Spinal manipulation force and duration affect vertebral movement and neuromuscular responses.

    PubMed

    Colloca, Christopher J; Keller, Tony S; Harrison, Deed E; Moore, Robert J; Gunzburg, Robert; Harrison, Donald D

    2006-03-01

    Previous study in human subjects has documented biomechanical and neurophysiological responses to impulsive spinal manipulative thrusts, but very little is known about the neuromechanical effects of varying thrust force-time profiles. Ten adolescent Merino sheep were anesthetized and posteroanterior mechanical thrusts were applied to the L3 spinous process using a computer-controlled, mechanical testing apparatus. Three variable pulse durations (10, 100, 200 ms, force = 80 N) and three variable force amplitudes (20, 40, 60 N, pulse duration = 100 ms) were examined for their effect on lumbar motion response (L3 displacement, L1, L2 acceleration) and normalized multifidus electromyographic response (L3, L4) using a repeated measures analysis of variance. Increasing L3 posteroanterior force amplitude resulted in a fourfold linear increase in L3 posteroanterior vertebral displacement (p < 0.001) and adjacent segment (L1, L2) posteroanterior acceleration response (p < 0.001). L3 displacement was linearly correlated (p < 0.001) to the acceleration response over the 20-80 N force range (100 ms). At constant force, 10 ms thrusts resulted in nearly fivefold lower L3 displacements and significantly increased segmental (L2) acceleration responses compared to the 100 ms (19%, p = 0.005) and 200 ms (16%, p = 0.023) thrusts. Normalized electromyographic responses increased linearly with increasing force amplitude at higher amplitudes and were appreciably affected by mechanical excitation pulse duration. Changes in the biomechanical and neuromuscular response of the ovine lumbar spine were observed in response to changes in the force-time characteristics of the spinal manipulative thrusts and may be an underlying mechanism in related clinical outcomes.

  4. Head-first impact with head protrusion causes noncontiguous injuries of the cadaveric cervical spine.

    PubMed

    Ivancic, Paul C

    2012-09-01

    To simulate horizontally aligned head-first impacts with initial head protrusion using a human cadaveric neck model and to determine biomechanical responses, injuries, and injury severity. Head-first impacts with initial head protrusion were simulated at 2.4 m/s using a human cadaver neck model (n = 10) mounted horizontally to a torso-equivalent mass on a sled and carrying a surrogate head. Macroscopic neck injuries were determined, and ligamentous injuries were quantified using fluoroscopy and visual inspection after the impacts. Representative time-history responses for injured specimens were determined during impact using load cell data and analyses of high-speed video. Biomechanics research laboratory. Cervical spines of 10 human cadavers. Injury severity at the middle and lower cervical spine was statistically compared using a 2-sample t test (P < 0.05). Neck buckling consisted of hyperflexion at C6/7 and C7/T1 and hyperextension at superior spinal levels. Noncontiguous neck injuries included forward dislocation at C7/T1, spinous process fracture and compression-extension injuries at the middle cervical spine, and atlas and odontoid fractures. Ligamentous injury severity at C7/T1 was significantly greater than at the middle cervical spine. Distinct injury mechanisms were observed throughout the neck, consisting of extension-compression and posterior shear at the upper and middle cervical spine and flexion-compression and anterior shear at C6/7 and C7/T1. Our experimental results highlight the importance of clinical awareness of potential noncontiguous cervical spine injuries due to head-first sports impacts.

  5. Msx genes are expressed in the carapacial ridge of turtle shell: a study of the European pond turtle, Emys orbicularis.

    PubMed

    Vincent, Christine; Bontoux, Martine; Le Douarin, Nicole M; Pieau, Claude; Monsoro-Burq, Anne-Hélène

    2003-09-01

    The turtle shell forms by extensive ossification of dermis ventrally and dorsally. The carapacial ridge (CR) controls early dorsal shell formation and is thought to play a similar role in shell growth as the apical ectodermal ridge during limb development. However, the molecular mechanisms underlying carapace development are still unknown. Msx genes are involved in the development of limb mesenchyme and of various skeletal structures. In particular, precocious Msx expression is recorded in skeletal precursors that develop close to the ectoderm, such as vertebral spinous processes or skull. Here, we have studied the embryonic expression of Msx genes in the European pond turtle, Emys orbicularis. The overall Msx expression in head, limb, and trunk is similar to what is observed in other vertebrates. We have focused on the CR area and pre-skeletal shell condensations. The CR expresses Msx genes transiently, in a pattern similar to that of fgf10. In the future carapace domain, the dermis located dorsal to the spinal cord expresses Msx genes, as in other vertebrates, but we did not see expansion of this expression in the dermis located more laterally, on top of the dermomyotomes. In the ventral plastron, although the dermal osseous condensations form in the embryonic Msx-positive somatopleura, we did not observe enhanced Msx expression around these elements. These observations may indicate that common mechanisms participate in limb bud and CR early development, but that pre-differentiation steps differ between shell and other skeletal structures and involve other gene activities than that of Msx genes.

  6. Caudal lumbar vertebral fractures in California Quarter Horse and Thoroughbred racehorses.

    PubMed

    Collar, E M; Zavodovskaya, R; Spriet, M; Hitchens, P L; Wisner, T; Uzal, F A; Stover, S M

    2015-09-01

    To gain insight into the pathophysiology of equine lumbar vertebral fractures in racehorses. To characterise equine lumbar vertebral fractures in California racehorses. Retrospective case series and prospective case-control study. Racehorse post mortem reports and jockey injury reports were retrospectively reviewed. Vertebral specimens from 6 racehorses affected with lumbar vertebral fractures and 4 control racehorses subjected to euthanasia for nonspinal fracture were assessed using visual, radiographic, computed tomography and histological examinations. Lumbar vertebral fractures occurred in 38 Quarter Horse and 29 Thoroughbred racehorses over a 22 year period, primarily involving the 5th and/or 6th lumbar vertebrae (L5-L6; 87% of Quarter Horses and 48% of Thoroughbreds). Lumbar vertebral fractures were the third most common musculoskeletal cause of death in Quarter Horses and frequently involved a jockey injury. Lumbar vertebral specimens contained anatomical variations in the number of vertebrae, dorsal spinous processes and intertransverse articulations. Lumbar vertebral fractures examined in 6 racehorse specimens (5 Quarter Horses and one Thoroughbred) coursed obliquely in a cranioventral to caudodorsal direction across the adjacent L5-L6 vertebral endplates and intervertebral disc, although one case involved only one endplate. All cases had evidence of abnormalities on the ventral aspect of the vertebral bodies consistent with pre-existing, maladaptive pathology. Lumbar vertebral fractures occur in racehorses with pre-existing pathology at the L5-L6 vertebral junction that is likely predisposes horses to catastrophic fracture. Knowledge of these findings should encourage assessment of the lumbar vertebrae, therefore increasing detection of mild vertebral injuries and preventing catastrophic racehorse and associated jockey injuries. © 2014 EVJ Ltd.

  7. Variation in the insertion of the latissimus dorsi & its clinical importance.

    PubMed

    Bhatt, C R; Prajapati, B; Patil, D S; Patel, V D; Singh, Binodkumar G P; Mehta, C D

    2013-01-01

    The latissimus dorsi is the larger, flat, dorso-lateral muscle on the trunk, posterior to the arm, and partly covered by the trapezius on its median dorsal region. Origin of the latissimus dorsi is from spinous processes of thoracic T7-T12, thoracolumbar fascia, iliac crest and inferior 3 or 4 ribs, inferior angle of scapula and insertion on floor of intertubercular groove of the humerus. We have studied 50 cadavers in the different medical colleges in which we found 2% case of anterior and posterior slip of the muscle fibers with their extension up to the pectoralis major and teres major respectively. Usually, latissimus dorsi involve in extension, adduction, transverse extension also known as horizontal abduction, flexion from an extended position, and internal rotation of the shoulder joint. It also has a synergistic role in extension and lateral flexion of the lumbar spine. The latissimus dorsi may be used for the tendon graft surgeries. Tight latissimus dorsi has been shown to be one cause of chronic shoulder pain and chronic back pain. Because the latissimus dorsi connects the spine to the humerus, tightness in this muscle can manifest as either sub-optimal glenohumeral joint function (which leads to chronic shoulder pain) or tendinitis in the tendinous fasciae connecting the latissimus dorsi to the thoracic and lumbar spine. Latissimus dorsi used for pedicle transplant rotator cuff repair reconstruction of breast, face, scalp and cranium defect. The extra slip of the latissimus dorsi may puzzle any transplant operations. We as anatomist discuss the clinical implication of the extra slip of latissimus dorsi.

  8. Variation in the insertion of the latissimus dorsi & its clinical importance

    PubMed Central

    Bhatt, C.R.; Prajapati, B.; Patil, D.S.; Patel, V.D.; Singh, Binodkumar G.P.; Mehta, C.D.

    2013-01-01

    The latissimus dorsi is the larger, flat, dorso-lateral muscle on the trunk, posterior to the arm, and partly covered by the trapezius on its median dorsal region. Origin of the latissimus dorsi is from spinous processes of thoracic T7–T12, thoracolumbar fascia, iliac crest and inferior 3 or 4 ribs, inferior angle of scapula and insertion on floor of intertubercular groove of the humerus. We have studied 50 cadavers in the different medical colleges in which we found 2% case of anterior and posterior slip of the muscle fibers with their extension up to the pectoralis major and teres major respectively. Usually, latissimus dorsi involve in extension, adduction, transverse extension also known as horizontal abduction, flexion from an extended position, and internal rotation of the shoulder joint. It also has a synergistic role in extension and lateral flexion of the lumbar spine. The latissimus dorsi may be used for the tendon graft surgeries. Tight latissimus dorsi has been shown to be one cause of chronic shoulder pain and chronic back pain. Because the latissimus dorsi connects the spine to the humerus, tightness in this muscle can manifest as either sub-optimal glenohumeral joint function (which leads to chronic shoulder pain) or tendinitis in the tendinous fasciae connecting the latissimus dorsi to the thoracic and lumbar spine. Latissimus dorsi used for pedicle transplant rotator cuff repair reconstruction of breast, face, scalp and cranium defect. The extra slip of the latissimus dorsi may puzzle any transplant operations. We as anatomist discuss the clinical implication of the extra slip of latissimus dorsi. PMID:24403744

  9. Alternative radiation-free registration technique for image-guided pedicle screw placement in deformed cervico-thoracic segments.

    PubMed

    Kantelhardt, Sven R; Neulen, Axel; Keric, Naureen; Gutenberg, Angelika; Conrad, Jens; Giese, Alf

    2017-10-01

    Image-guided pedicle screw placement in the cervico-thoracic region is a commonly applied technique. In some patients with deformed cervico-thoracic segments, conventional or 3D fluoroscopy based registration of image-guidance might be difficult or impossible because of the anatomic/pathological conditions. Landmark based registration has been used as an alternative, mostly using separate registration of each vertebra. We here investigated a routine for landmark based registration of rigid spinal segments as single objects, using cranial image-guidance software. Landmark based registration of image-guidance was performed using cranial navigation software. After surgical exposure of the spinous processes, lamina and facet joints and fixation of a reference marker array, up to 26 predefined landmarks were acquired using a pointer. All pedicle screws were implanted using image guidance alone. Following image-guided screw placement all patients underwent postoperative CT scanning. Screw positions as well as intraoperative and clinical parameters were retrospectively analyzed. Thirteen patients received 73 pedicle screws at levels C6 to Th8. Registration of spinal segments, using the cranial image-guidance succeeded in all cases. Pedicle perforations were observed in 11.0%, severe perforations of >2 mm occurred in 5.4%. One patient developed a transient C8 syndrome and had to be revised for deviation of the C7 pedicle screw. No other pedicle screw-related complications were observed. In selected patients suffering from pathologies of the cervico-thoracic region, which impair intraoperative fluoroscopy or 3D C-arm imaging, landmark based registration of image-guidance using cranial software is a feasible, radiation-saving and a safe alternative.

  10. Finite element analysis of lordosis restoration with anterior longitudinal ligament release and lateral hyperlordotic cage placement.

    PubMed

    Uribe, Juan S; Harris, Jeffrey E; Beckman, J M; Turner, Alexander W L; Mundis, Gregory M; Akbarnia, Behrooz A

    2015-04-01

    Restoring sagittal alignment is an important factor in the treatment of spinal deformities. Recent investigations have determined that releasing the anterior longitudinal ligament (ALL) and placing hyperlordotic cages can increase lordosis, while minimizing need for 3 column osteotomies. The influences of parameters such as cage height and angle have not been determined. Finite element analysis was employed to assess the extent of lordosis achievable after placement of different sized lordotic cages. A 3-dimensional model of a L3-4 segment was used. Disc distraction was simulated by inserting interbody cages mid-body in the disc space. Analyses were performed in the following conditions: (1) intact, (2) ALL release, (3) ALL release + facetectomy, and (4) ALL release + posterior column osteotomy. Changes in segmental lordosis, disc height, foraminal height, and foraminal area were measured. After ALL resection and insertion of hyperlordotic cages, lordosis was increased in all cases. The lordosis achieved by the shorter cages was less due to posterior disc height maintained by the facet joints. A facetectomy increased segmental lordosis, but led to contact between the spinous processes. For some configurations, a posterior column osteotomy was required if the end goal was to match cage angle to intradiscal angle. Increased segmental lumbar lordosis is achievable with hyperlordotic cages after ALL resection. Increased cage height tended to increase the amount of lordosis achieved, although in some cases additional posterior bone resection was required to maximize lordosis. Further studies are needed to evaluate the impact on regional lumbar lordosis.

  11. Anterioposterior spinal curvatures and magnitude of asymmetry in the trunk in musicians playing the violin compared with nonmusicians.

    PubMed

    Barczyk-Pawelec, Katarzyna; Sipko, Tomasz; Demczuk-Włodarczyk, Ewa; Boczar, Agata

    2012-05-01

    Playing an instrument often requires a certain posture and asymmetric position that may affect the anteroposterior spinal curvatures and may lead to postural asymmetry. The aim of the study was to evaluate the spinal curvatures in the sagittal plane and the magnitude of asymmetries in the trunk in the frontal plane in a group of music students in comparison with a control group. The group of 67 students aged 20 to 26 years was made up of 2 subgroups: the musicians (violin playing students of the Academy of Music in Wroclaw) and the control group (physical therapy students who played no instruments). The examination included an interview, measuring of somatic characteristics, and evaluation of body posture by means of the photogrammetric method. The spinal curvatures of the instrumentalists in the sagittal plane differ from the control group mainly in terms of length and depth parameters. Compared with the control group, the musicians were characterized by statistically more significantly longer and deeper thoracic kyphosis (P < .01) and more shallow lumbar lordosis (P < .05), a greater angle of thoracic kyphosis (P < .005), and a smaller inclination angle of the thoracolumbar and lumbosacral section of the spine (P < .01). In the group of musicians, the asymmetries in the area of shoulders and waist triangles as well as the distance of the spinous processes from the C7 to S1 line were more frequent. Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.

  12. Validation, repeatability and reproducibility of a noninvasive instrument for measuring thoracic and lumbar curvature of the spine in the sagittal plane.

    PubMed

    Chaise, Fabiana O; Candotti, Cláudia T; Torre, Marcelo L; Furlanetto, Tássia S; Pelinson, Patricia P T; Loss, Jefferson F

    2011-01-01

    The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures. To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays. 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA. There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA. It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.

  13. Radiological Determination of Postoperative Cervical Fusion: A Systematic Review.

    PubMed

    Rhee, John M; Chapman, Jens R; Norvell, Daniel C; Smith, Justin; Sherry, Ned A; Riew, K Daniel

    2015-07-01

    Systematic review. To determine best criteria for radiological determination of postoperative subaxial cervical fusion to be applied to current clinical practice and ongoing future research assessing fusion to standardize assessment and improve comparability. Despite availability of multiple imaging modalities and criteria, there remains no method of determining cervical fusion with absolute certainty, nor clear consensus on specific criteria to be applied. A systematic search in MEDLINE/Cochrane Collaboration Library (through March 2014). Included studies assessed C2 to C7 via anterior or posterior approach, at 12 weeks or more postoperative, with any graft or implant. Overall body of evidence with respect to 6 posited key questions was determined using Grading of Recommendations Assessment, Development and Evaluation and Agency for Healthcare Research and Quality precepts. Of plain radiographical modalities, there is moderate evidence that the interspinous process motion method (<1 mm) is more accurate than the Cobb angle method for assessing anterior cervical fusion. Of the advanced imaging modalities, there is moderate evidence that computed tomography (CT) is more accurate and reliable than magnetic resonance imaging in assessing anterior cervical fusion. There is insufficient evidence regarding the optimal modality and criteria for assessing posterior cervical fusions and insufficient evidence to support a single time point after surgery as being optimal for determining fusion, although some evidence suggest that reliability of radiography and CT improves with increasing time postoperatively. We recommend using less than 1-mm motion as the initial modality for determining anterior cervical arthrodesis for both clinical and research applications. If further imaging is needed because of indeterminate radiographical evaluation, we recommend CT, which has relatively high accuracy and reliability, but due to greater radiation exposure and cost, it is not routinely suggested. We recommend that plain radiographs also be the initial method of determining posterior cervical fusion but suggest a lower threshold for obtaining CT scans because dynamic radiographs may not be as useful if spinous processes have been removed by laminectomy. 1.

  14. [Selective cervical dorsal root cutting off part of the vertebral lateral mass fixation combined with exercise therapy for treating spastic cerebral paralysis of the upper limbs caused by cerebral palsy].

    PubMed

    Zhang, Peng; Hu, Wei; Cao, Xu; Xu, Shi-gang; Li, De-kui; Xu, Lin

    2009-10-01

    To explore the feasibility and the result for the surgical treatment of spastic cerebral paralysis of the upper limbs in patients who underwent the selective cervical dorsal root cutting off part of the vertebral lateral mass fixation combined with exercise therapy. From March 2004 to April 2008, 27 patients included 19 boys and 8 girls, aging 13-21 years with an average of 15 years underwent selective cervical dorsal root cutting off part of the vertebral lateral mass fixation with exercise therapy. The AXIS 8 holes titanium plate was inserted into the lateral mass of spinous process through guidance of the nerve stimulator, choosed fasciculus of low-threshold nerve dorsal root and cut off its 1.5 cm. After two weeks, training exercise therapy was done in patients. Training will include lying position, turning body, sitting position, crawling, kneeling and standing position, walking and so on. Spastic Bobath inhibiting abnormal pattern was done in the whole process of training. The muscular tension, motor function (GMFM), functional independence (WeeFIM) were observed after treatment. All patients were followed up from 4 to 16 months with an average of 6 months. Muscular tension score were respectively 3.30 +/- 0.47 and 1.25 +/- 0.44 before and after treatment;GMFM score were respectively 107.82 +/- 55.17 and 131.28 +/- 46.45; WeeFIM score were respectively 57.61 +/- 25.51 and 87.91 +/- 22.39. There was significant improvement before and after treatment (P < 0.01). Selective cervical dorsal root cutting off part of the vertebral lateral mass fixation combined with exercise therapy was used to treat spastic cerebral paralysis of the upper limbs is safe and effective method, which can decrease muscular tension and improve motor function, which deserves more wide use.

  15. The vertebral remains of the late Miocene great ape Hispanopithecus laietanus from Can Llobateres 2 (Vallès-Penedès Basin, NE Iberian Peninsula).

    PubMed

    Susanna, Ivette; Alba, David M; Almécija, Sergio; Moyà-Solà, Salvador

    2014-08-01

    Here we describe the vertebral fragments from the partial skeleton IPS18800 of the fossil great ape Hispanopithecus laietanus (Hominidae: Dryopithecinae) from the late Miocene (9.6 Ma) of Can Llobateres 2 (Vallès-Penedès Basin, Catalonia, Spain). The eight specimens (IPS18800.5-IPS18800.12) include a fragment of thoracic vertebral body, three partial bodies and four neural arch fragments of lumbar vertebrae. Despite the retention of primitive features (moderately long lumbar vertebral bodies with slightly concave ventrolateral sides), these specimens display a suite of derived, modern hominoid-like features: thoracic vertebrae with dorsally-situated costal foveae; lumbar vertebrae with non-ventrally-oriented transverse processes originating from a robust pedicle, caudally-long laminae with caudally-oriented spinous process, elliptical end-plates, and moderately stout bodies reduced in length and with no ventral keel. These features, functionally related to orthograde behaviors, are indicative of a broad and shallow thorax with a moderately short and stiff lumbar region in Hispanopithecus. Despite its large body mass (ca. 39-40 kg), its vertebral morphology is more comparable to that of hylobatids and Ateles than to extant great apes. This is confirmed by our morphometric analyses, also indicating that Hispanopithecus most closely resembles Pierolapithecus and Morotopithecus among Miocene apes, whereas Proconsul and Nacholapithecus resemble pronograde monkeys. Only in a few features (craniocaudally short and transversely wide pedicles, transverse processes situated on the pedicle, and slight ventral wedging), Hispanopithecus is more derived towards the extant great ape condition than other Miocene apes. Overall, the vertebral morphology of Hispanopithecus supports previous inferences of an orthograde body plan with suspensory and climbing adaptations. However, given similarities with Ateles and the retention of a longer and more flexible spine than in extant great apes, the Hispanopithecus morphology is also consistent with some degree of above-branch quadrupedalism, as previously inferred from other anatomical regions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Tissue distribution and subcellular localizations determine in vivo functional relationship among prostasin, matriptase, HAI-1, and HAI-2 in human skin.

    PubMed

    Lee, Shiao-Pieng; Kao, Chen-Yu; Chang, Shun-Cheng; Chiu, Yi-Lin; Chen, Yen-Ju; Chen, Ming-Hsing G; Chang, Chun-Chia; Lin, Yu-Wen; Chiang, Chien-Ping; Wang, Jehng-Kang; Lin, Chen-Yong; Johnson, Michael D

    2018-01-01

    The membrane-bound serine proteases prostasin and matriptase and the Kunitz-type protease inhibitors HAI-1 and HAI-2 are all expressed in human skin and may form a tightly regulated proteolysis network, contributing to skin pathophysiology. Evidence from other systems, however, suggests that the relationship between matriptase and prostasin and between the proteases and the inhibitors can be context-dependent. In this study the in vivo zymogen activation and protease inhibition status of matriptase and prostasin were investigated in the human skin. Immunohistochemistry detected high levels of activated prostasin in the granular layer, but only low levels of activated matriptase restricted to the basal layer. Immunoblot analysis of foreskin lysates confirmed this in vivo zymogen activation status and further revealed that HAI-1 but not HAI-2 is the prominent inhibitor for prostasin and matriptase in skin. The zymogen activation status and location of the proteases does not support a close functional relation between matriptase and prostasin in the human skin. The limited role for HAI-2 in the inhibition of matriptase and prostasin is the result of its primarily intracellular localization in basal and spinous layer keratinocytes, which probably prevents the Kunitz inhibitor from interacting with active prostasin or matriptase. In contrast, the cell surface expression of HAI-1 in all viable epidermal layers renders it an effective regulator for matriptase and prostasin. Collectively, our study suggests the importance of tissue distribution and subcellular localization in the functional relationship between proteases and protease inhibitors.

  17. In vitro Neurons in Mammalian Cortical Layer 4 Exhibit Intrinsic Oscillatory Activity in the 10- to 50-Hz Frequency Range

    NASA Astrophysics Data System (ADS)

    Llinas, Rodolfo R.; Grace, Anthony A.; Yarom, Yosef

    1991-02-01

    We report here the presence of fast subthreshold oscillatory potentials recorded in vitro from neurons within layer 4 of the guinea pig frontal cortex. Two types of oscillatory neurons were recorded: (i) One type exhibited subthreshold oscillations whose frequency increased with membrane depolarization and encompassed a range of 10-45 Hz. Action potentials in this type of neuron demonstrated clear after-hyperpolarizations. (ii) The second type of neuron was characterized by narrow-frequency oscillations near 35-50 Hz. These oscillations often outlasted the initiating depolarizing stimulus. No calcium component could be identified in their action potential. In both types of cell the subthreshold oscillations were tetrodotoxin-sensitive, indicating that the depolarizing phase of the oscillation was generated by a voltage-dependent sodium conductance. The initial depolarizing phase was followed by a potassium conductance responsible for the falling phase of the oscillatory wave. In both types of cell, the subthreshold oscillation could trigger spikes at the oscillatory frequency, if the membrane was sufficiently depolarized. Combining intracellular recordings with Lucifer yellow staining showed that the narrow-frequency oscillatory activity was produced by a sparsely spinous interneuron located in layer 4 of the cortex. This neuron has extensive local axonal collaterals that ramify in layers 3 and 4 such that they may contribute to the columnar synchronization of activity in the 40- to 50-Hz range. Cortical activity in this frequency range has been proposed as the basis for the "conjunctive properties" of central nervous system networks.

  18. Terraranans of the Lost World: a new species of Pristimantis (Amphibia, Craugastoridae) from Abakapá-tepui in the Chimantá massif, Venezuelan Guayana, and additions to the knowledge of P. muchimuk.

    PubMed

    Rojas-Runjaic, Fernando J M; Salerno, Patricia E; Señaris, J Celsa; Pauly, Gregory B

    2013-01-01

    A new frog of the genus Pristimantis is named and described from the summit of Abakapá-tepui in the Chimantd massif, south-eastern Venezuela. The new species is known from two adult specimens and is the second craugastorid species described from this massif. It can be readily distinguished from all congeners inhabiting the highlands of the Guiana Shield by the unique combination of the following characters: dorsal skin shagreen and ventral skin coarsely areolate, tympanum small and ill-defined, vocal slits absent in males, finger I shorter than II, thumbs with two whitish and non-spinous nuptial pads in adult males, fingers and toes with broad lateral fringes, basal webbing between all toes, throat and chest nacreous white in life. Also, based on five specimens of Pristimantis muchimuk recently collected from Churi-tepui, we provide new information on this little known species, including an amended diagnosis, notes on morphology, color variation, advertisement calls, and natural history.

  19. A morphometric study on the cross-sections of the scapular spine in dogs.

    PubMed

    Ocal, M K; Toros, G

    2007-01-01

    In cases of unstable scapular body fractures, the base of the scapular spine is one of the sites where there is adequate bone for the application of plate fixation in dogs. In this type of fixation, the amount of bone is an important factor with regard to the holding power of the screw from the biomechanical viewpoint. Therefore, the aim of this paper is to present the detailed quantitative features of the sectional area of the scapular spine in dogs. A total of 28 scapulas from 14 dogs were used, and each was divided into 10 equal slices The height of the scapular spine, depths of the supra-spinous and infraspinus fossae were measured from the scanned images with the aid of a computer program. The results showed that the depth of the supraspinous fossa was greater in the ventral half of the spine, while the depth of the infraspinous was greater in the dorsal half. The differences between the depths of the two fossae were noticeable in the ventral half of the scapular spine.

  20. Middle and lower trapezius strengthening for the management of lateral epicondylalgia: a case report.

    PubMed

    Bhatt, Jiten B; Glaser, Randal; Chavez, Andre; Yung, Emmanuel

    2013-11-01

    Case report. Addressing weakness of the shoulder region, especially the rotator cuff and scapular musculature, is often suggested clinically for the treatment of individuals with lateral epicondylalgia. However, to our knowledge, the clinical effectiveness of this approach has not been established. The patient was a 54-year-old woman with a 5-month history of right lateral elbow pain, whose symptoms were reproduced with clinical tests typically used to diagnose lateral elbow tendinopathy. The patient also demonstrated weakness in her middle and lower trapezius muscles, and the medial border of her scapula, measured with a tape measure, was 11 cm lateral from the spinous processes of the thoracic spine with the patient standing in relaxed stance. Based on improved grip strength and reduced associated elbow pain when tested with the scapula manually corrected in a more adducted position, treatment focused solely on strengthening of the middle and lower trapezius muscles over a 10-week period. Following the intervention, the patient presented with improved scapular position, with the medial border of the scapula being 9 cm lateral to the midthoracic spine. The patient's middle and lower trapezius strength improved from 3+/5 and 4-/5, respectively, to 5/5, and her grip strength from 26.1 to 42.2 kg. The patient's scores on the Disabilities of the Arm, Shoulder and Hand questionnaire also improved from 44.2 at the initial evaluation to 0 at the completion of therapy, with the patient being able to perform all of her daily activities in a pain-free manner. The results of this case report suggest that assessment and treatment of scapular musculature warrant consideration in the management of individuals with lateral epicondylalgia. Therapy, level 4.

  1. Dropped head syndrome after cervical laminoplasty: A case control study.

    PubMed

    Koda, Masao; Furuya, Takeo; Kinoshita, Tomoaki; Miyashita, Tomohiro; Ota, Mitsutoshi; Maki, Satoshi; Ijima, Yasushi; Saito, Junya; Takahashi, Kazuhisa; Yamazaki, Masashi; Aramomi, Masaaki; Mannoji, Chikato

    2016-10-01

    Dropped head syndrome (DHS) is characterized by apparent neck extensor muscle weakness and difficulty extending the neck to raise the head against gravity. The aim of the present study was to elucidate possible risk factors for DHS after cervical laminoplasty. Five patients who developed DHS after cervical laminoplasty (DHS group) and twenty age-matched patients who underwent laminoplasty without DHS after surgery (control group) were compared. The surgical procedure was single-door laminoplasty with strut grafting using resected spinous processes or hydroxyapatite spacers from C3 to C6 or C7. Analyses of preoperative images including the C2-C7 angle, C7-T1 kyphosis, T1 tilt, center of gravity line from the head-C7 sagittal vertical axis (CGH-C7 SVA) were performed on lateral plain cervical spine radiographs. Preoperative T2-weighted MRI at the C5 vertebral level was used to measure the cross-sectional area of the deep extensor muscles. Widths of the lateral gutters were assessed postoperatively using CT scans of the C5 vertebral body. The average preoperative C2-C7 angle was significantly smaller in the DHS group compared with the control group. The average preoperative C7-T1 angle was significantly larger in the DHS group compared with the control group. The average preoperative CGH-C7 SVA was significantly larger in the DHS group compared with the control group. In conclusion, patients with more pronounced preoperative C2-C7 kyphosis, C7-T1 kyphosis, and CGH-C7 SVA are more likely to develop DHS following laminoplasty. Copyright © 2016. Published by Elsevier Ltd.

  2. Fetal development of deep back muscles in the human thoracic region with a focus on transversospinalis muscles and the medial branch of the spinal nerve posterior ramus

    PubMed Central

    Sato, Tatsuo; Koizumi, Masahiro; Kim, Ji Hyun; Kim, Jeong Hyun; Wang, Bao Jian; Murakami, Gen; Cho, Baik Hwan

    2011-01-01

    Fetal development of human deep back muscles has not yet been fully described, possibly because of the difficulty in identifying muscle bundle directions in horizontal sections. Here, we prepared near-frontal sections along the thoracic back skin (eight fetuses) as well as horizontal sections (six fetuses) from 14 mid-term fetuses at 9–15 weeks of gestation. In the deep side of the trapezius and rhomboideus muscles, the CD34-positive thoracolumbar fascia was evident even at 9 weeks. Desmin-reactivity was strong and homogeneous in the superficial muscle fibers in contrast to the spotty expression in the deep fibers. Thus, in back muscles, formation of the myotendinous junction may start from the superficial muscles and advance to the deep muscles. The fact that developing intramuscular tendons were desmin-negative suggested little possibility of a secondary change from the muscle fibers to tendons. We found no prospective spinalis muscle or its tendinous connections with other muscles. Instead, abundant CD68-positive macrophages along the spinous process at 15 weeks suggested a change in muscle attachment, an event that may result in a later formation of the spinalis muscle. S100-positive intramuscular nerves exhibited downward courses from the multifidus longus muscle in the original segment to the rotatores brevis muscles in the inferiorly adjacent level. The medial cutaneous nerve had already reached the thoracolumbar fascia at 9 weeks, but by 15 weeks the nerve could not penetrate the trapezius muscle. Finally, we propose a folded myotomal model of the primitive transversospinalis muscle that seems to explain a fact that the roofing tile-like configuration of nerve twigs in the semispinalis muscle is reversed in the multifidus and rotatores muscles. PMID:21954879

  3. Sensor positioning and experimental constraints influence estimates of local dynamic stability during repetitive spine movements.

    PubMed

    Howarth, Samuel J; Graham, Ryan B

    2015-04-13

    Application of non-linear dynamics analyses to study human movement has increased recently, which necessitates an understanding of how dependent measures may be influenced by experimental design and setup. Quantifying local dynamic stability for a multi-articulated structure such as the spine presents the possibility for estimates to be influenced by positioning of kinematic sensors used to measure spine angular kinematics. Oftentimes researchers will also choose to constrain the spine's movement by physically restraining the pelvis and/or using targets to control movement endpoints. Ten healthy participants were recruited, and asked to perform separate trials of 35 consecutive cycles of spine flexion under both constrained and unconstrained conditions. Electromagnetic sensors that measure three-dimensional angular orientations were positioned over the pelvis and the spinous processes of L3, L1, and T11. Using the pelvic sensor as a reference, each sensor location on the spine was used to obtain a different representation of the three-dimensional spine angular kinematics. Local dynamic stability of each kinematic time-series was determined by calculating the maximum finite-time Lyapunov exponent (λmax). Estimates for λmax were significantly lower (i.e. dynamically more stable) for spine kinematic data obtained from the L3 sensor than those obtained from kinematic data using either the L1 or T11 sensors. Likewise, λmax was lower when the movement was constrained. These results emphasize the importance of proper placement of instrumentation for quantifying local dynamic stability of spine kinematics and are especially relevant for repeated measures designs where data are obtained from the same individual on multiple days. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Dynamic anterior cervical plates for multilevel anterior corpectomy and fusion with simultaneous posterior wiring and fusion: efficacy and outcomes.

    PubMed

    Epstein, N E

    2006-07-01

    To prospectively evaluate major complications associated with the application of dynamic ABC plates (Aesculap, Tuttlingen, Germany) to multilevel Anterior Corpectomy/Fusion (ACF) followed by posterior fusion (C2-C7 PF). To determine whether dynamic ABC (Aesculap, Tuttlingen, Germany) plates would minimize major complications (plate/graft extrusion, pseudarthrosis) while maximizing neurological outcomes in 40 consecutive patients undergoing simultaneous multilevel ACF/PF with halo application. USA. Patients averaged 53 years of age and preoperatively exhibited severe myeloradiculopathy (Nurick Grade 3.9). MR/CT studies documented marked ossification of the posterior longitudinal ligament/spondylostenosis. Surgery included two to four level ACF utilizing fibula strut allograft and ABC plates. Posterior spinous process wiring/fusions utilized braided titanium cables. The average operative time was 8.9 h. Fusion was confirmed on dynamic X-rays/CTs (3-12 months postoperatively). The average follow-up interval was 2.7 years. Outcomes (3 months-2 years postoperatively) were assessed utilizing Odom's Criteria, Nurick Grades, and SF-36 questionnaires. Major complications included one pseudarthrosis requiring secondary PWF. Minor complications in six patients included two pulmonary emboli (PE), two tracheostomies, and five superficial wound infections. At 1 year postoperatively, marked improvement was observed in all patients utilizing Odom's criteria (38 excellent/good), Nurick Grades (mild radiculopathy 0.4), and the SF-36 (3 Health Scales; Role Physical (12.5-38.6), Bodily Pain (39.9-65.5), and Role Emotional (53.8-75.8)]. The 2-year postoperative data showed minimal additional improvement. The average time to fusion was 6.3 months. Patients undergoing multilevel ACF/PF demonstrated marked neurological improvement (SF-36), and only one of 40 developed a delayed pseudarthrosis.

  5. Does age of fracture affect the outcome of vertebroplasty? Results from data from a prospective multicenter FDA IDE study.

    PubMed

    Syed, Mubin I; Shaikh, Azim

    2012-11-01

    To evaluate whether the age of a fracture is a variable that can identify patients for whom vertebroplasty would be most beneficial. Data from 256 patients with painful osteoporotic vertebral compression fractures (VCFs) who underwent vertebroplasty were examined to assess the effect of fracture age on outcomes. Patients ranged in age from 34-76 years, and the age of fractures ranged from 6 weeks or less (n = 117) to more than 52 weeks (n = 3). Most patients had a fracture age of 12 weeks or less (n = 207), with only 17% having a fracture age greater than 12 weeks. The duration of back pain was used as a surrogate for fracture age and was confirmed by edema on magnetic resonance (MR) imaging, abnormal bone scans, and the presence of central pain over the spinous process The primary outcome was pain reduction as determined by the change in the visual analog scale (VAS) pain score from baseline and at 1, 3, 6, and 24 months after vertebroplasty. A fracture age of 12 weeks or less versus greater than 12 weeks did not affect outcomes, with patients in both groups achieving equivalent benefit after vertebroplasty. Patients with a fracture age of 6 weeks or less had a slightly improved benefit at 3 months after vertebroplasty compared with those having a fracture age of greater than 6 weeks, but the benefit beyond 3 months was the same. Results of the study showed that the age of a fracture does not independently affect the outcomes of vertebroplasty. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.

  6. A preliminary study into injuries due to non-perforating ballistic impacts into soft body armour over the spine.

    PubMed

    Jennings, Rosalind M; Malbon, Chris; Brock, Fiona; Harrisson, Stuart; Carr, Debra J

    2018-05-22

    The UK Home Office test method for ballistic protective police body armours considers anterior torso impacts to be the worst-case scenario and tests rear armour panels to the same standards as front panels. The aim of this paper was to examine the injuries from spinal behind armour blunt trauma (BABT) impacts. This study used a cadaveric 65 kg, female pig barrel and 9 mm Luger ammunition (9 × 19 mm, FMJ Nammo Lapur Oy) into HG1/A + KR1 soft armour panels over the spine. Injuries were inspected and sections removed for x-radiography and micro-CT assessment. All shots over the spine resulted in deep soft tissue injuries from pencilling of the armour and the shirt worn under the armour. The wounds had embedded fabric debris which would require surgery to remove resulting in increased recovery time over injuries usually seen in anterior torso BABT impacts, which are typically haematoma and fractured ribs. The shot with the deepest soft tissue wound (41 mm) also resulted in a fractured spinous process. Shots were also fired at the posterior and anterior rib area of the pig barrel, for comparison to the spine. Similar wounds were seen on the shots to the posterior rib area while shallower, smaller wounds were seen on the anterior and one anterior rib shot resulted in a single, un-displaced rib fracture. The anatomical differences between pigs and humans would most likely mean that injury to a human from these impacts would be more serious. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  7. Effect of lumbar fasciae on the stability of the lower lumbar spine.

    PubMed

    Choi, Hae Won; Kim, Young Eun

    2017-10-01

    The biomechanical effect of tensioning the lumbar fasciae (LF) on the stability of the spine during sagittal plane motion was analysed using a validated finite element model of the normal lumbosacral spine (L4-S1). To apply the tension in the LF along the direction of the fibres, a local coordinate was allocated using dummy rigid beam elements that originated from the spinous process. Up to 10 Nm of flexion and 7.5 Nm of extension moment was applied with and without 20 N of lateral tension in the LF. A follower load of 400 N was additionally applied along the curvature of the spine. To identify how the magnitude of LF tension related to the stability of the spine, the tensioning on the fasciae was increased up to 40 N with an interval of 10 N under 7.5 Nm of flexion/extension moment. A fascial tension of 20 N produced a 59% decrease in angular motion at 2.5 Nm of flexion moment while there was a 12.3% decrease at 10 Nm in the L5-S1 segment. Its decrement was 53 and 9.6% at 2.5 Nm and 10 Nm, respectively, in the L4-L5 segment. Anterior translation was reduced by 12.1 and 39.0% at the L4-L5 and L5-S1 segments under 10 Nm of flexion moment, respectively. The flexion stiffness shows an almost linear increment with the increase in fascial tension. The results of this study showed that the effect of the LF on the stability of the spine is significant.

  8. Comparison of cervical spine stiffness in individuals with chronic nonspecific neck pain and asymptomatic individuals.

    PubMed

    Ingram, Lewis A; Snodgrass, Suzanne J; Rivett, Darren A

    2015-03-01

    Clinical measurement, cross-sectional. To determine if spinal joint stiffness is different in individuals with nonspecific neck pain, and whether stiffness magnitude is associated with pain intensity and disability. Manual therapists commonly evaluate spinal joint stiffness in patients presenting with nonspecific neck pain. However, a relationship between stiffness and neck pain has not yet been demonstrated. Spinal stiffness at C7 was objectively measured in participants with chronic nonspecific neck pain whose symptomatic spinal level was identified as C7 (n = 12) and in age- and sex-matched asymptomatic controls (n = 12). Stiffness (slope of the linear region of the force-displacement curve) was quantified using a device that applied 5 standardized mechanical force cycles to the C7 spinous process, while concurrently measuring displacement and resistance to movement. Stiffness was compared between groups using an independent t test. Spearman rho and Pearson r were used to determine the extent to which stiffness magnitude was associated with pain intensity (visual analog scale) and level of disability (Neck Disability Index), respectively, in the group with neck pain. Participants with nonspecific neck pain had greater spinal joint stiffness at C7 compared with asymptomatic individuals (mean difference, 1.78 N/mm; 95% confidence interval: 0.28, 3.27; P = .022). However, stiffness magnitude in the group with neck pain was not associated (P>.05) with pain intensity or level of disability. These preliminary results suggest that cervical spine stiffness may be greater in the presence of nonspecific neck pain. However, judgments regarding pain intensity and level of disability should not be inferred from examinations of spinal joint stiffness.

  9. Are Spinal or Paraspinal Anatomic Markers Helpful for Vertebral Numbering and Diagnosing Lumbosacral Transitional Vertebrae?

    PubMed Central

    Ucar, Murat; Erdogan, Aylin Billur; Kilic, Koray; Ozcan, Cahide

    2014-01-01

    Objective To evaluate the value of spinal and paraspinal anatomic markers in both the diagnosis of lumbosacral transitional vertebrae (LSTVs) and identification of vertebral levels on lumbar MRI. Materials and Methods Lumbar MRI from 1049 adult patients were studied. By comparing with the whole-spine localizer, the diagnostic errors in numbering vertebral segments on lumbar MRI were evaluated. The morphology of S1-2 disc, L5 and S1 body, and lumbar spinous processes (SPs) were evaluated by using sagittal MRI. The positions of right renal artery (RRA), superior mesenteric artery, aortic bifurcation (AB) and conus medullaris (CM) were described. Results The diagnostic error for evaluation of vertebral segmentation on lumbar MRI alone was 14.1%. In lumbarization, all patients revealed a well-formed S1-2 disc with squared S1 body. A rhombus-shaped L5 body in sacralization and a rectangular-shaped S1 body in lumbarization were found. The L3 had the longest SP. The most common sites of spinal and paraspinal structures were: RRA at L1 body (53.6%) and L1-2 disc (34.1%), superior mesenteric artery at L1 body (55.1%) and T12-L1 disc (31.6%), and AB at L4 body (71.1%). CM had variable locations, changing from the T12-L1 disc to L2 body. They were located at higher sacralization and lower lumbarization. Conclusion The spinal morphologic features and locations of the spinal and paraspinal structures on lumbar MRI are not completely reliable for the diagnosis of LSTVs and identification on the vertebral levels. PMID:24644411

  10. A Novel Minimally Invasive Wireless Technology for Neuromodulation via Percutaneous Intercostal Nerve Stimulation for Post-Herpetic Neuralgia: A Case Report with Short-Term Follow-up.

    PubMed

    Billet, Bart; Wynendaele, Roel; Vanquathem, Niek E

    2018-03-01

    Peripheral nerve stimulation of primary afferent neurons provides control of localized chronic pain. This technique applies permanent electrical stimulation at the target area via a minimally invasive, subcutaneous placement of an electrode. To assess the analgesic effects of minimally invasive wireless neuromodulation in the treatment of chronic intractable pain secondary to post-herpetic neuralgia. A 78-year-old man presented with severe intractable post-herpetic neuralgic pain. He was known to have non-Hodgkin's lymphoma under remission following treatment with chemotherapy and stem cell transplantation, twice. He also developed steroid-induced diabetes mellitus during this treatment. In view of his compromised immune status, he was deemed a suitable candidate for our minimally invasive neuromodulation technology. Two subcutaneous electrodes were placed on the right-hand side of the trunk, 10 cm medial and parallel to the spinous process at the level of T7-T8 under fluoroscopic guidance along the T7 intercostal nerve. The external transmitter was worn with a belt over a single layer of clothing and used to transmit power to the stimulator. The entire procedure required only a small incision for the introduction of the electrode placement. After an uneventful procedure, the pain score decreased from 8 to 3, with a reduction in pain medication. The EuroQol Five Dimensions Questionnaire scores were 0.102 before the trial, 0.630 at 1 month, and 0.576 at 3 months. Subcutaneous placement of electrodes with our minimally invasive technique and wireless neuromodulation technology was safe and effective. Significant improvements in pain relief ensued, and no further adverse events had been reported at the end of 3 months' follow-up. © 2017 World Institute of Pain.

  11. Asymmetric C7 pedicle subtraction osteotomy for correction of rigid cervical coronal imbalance secondary to post-traumatic heterotopic ossification: a case report, description of a novel surgical technique, and literature review.

    PubMed

    Theologis, Alexander A; Bellevue, Kate D; Qamirani, Erion; Ames, Christopher P; Deviren, Vedat

    2017-05-01

    Deformities of the cervical spine are uncommon in the coronal plane. In this report, a unique case of a 31-year-old male with a fixed, 30° left coronal deformity due to heterotopic ossification 3 years status post poly-trauma was treated with an asymmetric C7 pedicle subtraction osteotomy (PSO). Case report. Pre-operatively, the patient had a fixed 45-degree left tilt of his neck and radiographs demonstrated a rigid 30° scoliosis, 7 cm coronal imbalance, and 4 cm negative sagittal balance, diffuse bridging bone between the spinous processes and the facet joints of C5 to T1 bilaterally. An asymmetric C7 PSO with C2-T3 posterior spinal fusion was completed without complication. There was residual 9° coronal deformity, 2.9 cm left coronal imbalance, and 2.3 cm sagittal imbalance. He had a marked improvement in his function, as assessed by the SF-36 physical component score (pre-op 31.1; post-op 44.7) and mental component score (pre-op 46.0; post-op 66.8). Post-operatively, neck disability index scores also improved (pre-op 38; post-op 16). Although the patient passed away from a drug overdose 14 months post-operatively, he did not report neck pain, he had not sought evaluation from another physician for his neck, and he had not undergone a subsequent neck operation before his passing. In this one patient, an asymmetric C7 PSO was performed safely. While it was effective in addressing a fixed cervical coronal imbalance, its efficacy and safety profile should be confirmed in larger cohorts.

  12. New method of scoliosis assessment: preliminary results using computerized photogrammetry.

    PubMed

    Aroeira, Rozilene Maria Cota; Leal, Jefferson Soares; de Melo Pertence, Antônio Eustáquio

    2011-09-01

    A new method for nonradiographic evaluation of scoliosis was independently compared with the Cobb radiographic method, for the quantification of scoliotic curvature. To develop a protocol for computerized photogrammetry, as a nonradiographic method, for the quantification of scoliosis, and to mathematically relate this proposed method with the Cobb radiographic method. Repeated exposure to radiation of children can be harmful to their health. Nevertheless, no nonradiographic method until now proposed has gained popularity as a routine method for evaluation, mainly due to a low correspondence to the Cobb radiographic method. Patients undergoing standing posteroanterior full-length spine radiographs, who were willing to participate in this study, were submitted to dorsal digital photography in the orthostatic position with special surface markers over the spinous process, specifically the vertebrae C7 to L5. The radiographic and photographic images were sent separately for independent analysis to two examiners, trained in quantification of scoliosis for the types of images received. The scoliosis curvature angles obtained through computerized photogrammetry (the new method) were compared to those obtained through the Cobb radiographic method. Sixteen individuals were evaluated (14 female and 2 male). All presented idiopathic scoliosis, and were between 21.4 ± 6.1 years of age; 52.9 ± 5.8 kg in weight; 1.63 ± 0.05 m in height, with a body mass index of 19.8 ± 0.2. There was no statistically significant difference between the scoliosis angle measurements obtained in the comparative analysis of both methods, and a mathematical relationship was formulated between both methods. The preliminary results presented demonstrate equivalence between the two methods. More studies are needed to firmly assess the potential of this new method as a coadjuvant tool in the routine following of scoliosis treatment.

  13. Comparative anatomy and osteohistology of hyperelongate neural spines in the sphenacodontids Sphenacodon and Dimetrodon (Amniota: Synapsida).

    PubMed

    Huttenlocker, Adam K; Rega, Elizabeth; Sumida, Stuart S

    2010-12-01

    Osteohistological investigations of hyperelongate vertebral spinous processes (neural spines) are presented to elucidate previously unknown aspects of dorsal sail form and function in two, closely related genera of "sail-backed" synapsids: Sphenacodon and Dimetrodon. Although recent and classic surveys of bone histology in extinct vertebrates have sampled the genus Dimetrodon, new sectioning of Sphenacodon material allows a comparative analysis of these structures among Sphenacodontidae for the first time. Variability within the histological organization of the neural spine is assessed by examining multiple regions along its length, and implications for soft tissue correlates, growth and mechanics are considered here. Both genera exhibit extensive parallel-fibered and fibrolamellar bone, in addition to lamellar bone. Several features vary along the length of the spine in each species. Muscle scars and extensive Sharpey's fibers are present at the base of the spine; no scars and fewer fibers are manifested ∼55-60 mm above the zygapophyses in mature individuals. The distal cortex of the spine does not exhibit greater vascularity than the proximal region in either genus. However, both genera manifest distinct vascular grooves of variable size along the distal periosteal surface, some of which become incorporated into the distal cortex. The observed histovariability appears to record the transition from the proximal (epaxial muscle embedded) to the distally protruding portion of the spine. These observations and independent pathological evidence support the existence of a short dorsal crest in Sphenacodon and possibly other basal sphenacodontids. Although the thermoregulatory capacity of such a crest remains uncertain, developmental and mechanical features are readily interpretable and are discussed with respect to the origins and early evolution of the dorsal sail in sphenacodontid synapsids. © 2010 Wiley-Liss, Inc.

  14. Conservative treatment of idiopathic scoliosis according to FITS concept: presentation of the method and preliminary, short term radiological and clinical results based on SOSORT and SRS criteria

    PubMed Central

    2011-01-01

    Background Conservative scoliosis therapy according to the FITS Concept is applied as a unique treatment or in combination with corrective bracing. The aim of the study was to present author's method of diagnosis and therapy for idiopathic scoliosis FITS-Functional Individual Therapy of Scoliosis and to analyze the early results of FITS therapy in a series of consecutive patients. Methods The analysis comprised separately: (1) single structural thoracic, thoracolumbar or lumbar curves and (2) double structural scoliosis-thoracic and thoracolumbar or lumbar curves. The Cobb angle and Risser sign were analyzed at the initial stage and at the 2.8-year follow-up. The percentage of patients improved (defined as decrease of Cobb angle of more than 5 degrees), stable (+/- 5 degrees), and progressed (increase of Cobb angle of more than 5 degrees) was calculated. The clinical assessment comprised: the Angle of Trunk Rotation (ATR) initial and follow-up value, the plumb line imbalance, the scapulae level and the distance from the apical spinous process of the primary curve to the plumb line. Results In the Group A: (1) in single structural scoliosis 50,0% of patients improved, 46,2% were stable and 3,8% progressed, while (2) in double scoliosis 50,0% of patients improved, 30,8% were stable and 19,2% progressed. In the Group B: (1) in single scoliosis 20,0% of patients improved, 80,0% were stable, no patient progressed, while (2) in double scoliosis 28,1% of patients improved, 46,9% were stable and 25,0% progressed. Conclusion Best results were obtained in 10-25 degrees scoliosis which is a good indication to start therapy before more structural changes within the spine establish. PMID:22122964

  15. Defining Optimal Head-Tilt Position of Resuscitation in Neonates and Young Infants Using Magnetic Resonance Imaging Data

    PubMed Central

    Bhalala, Utpal S.; Hemani, Malvi; Shah, Meehir; Kim, Barbara; Gu, Brian; Cruz, Angelo; Arunachalam, Priya; Tian, Elli; Yu, Christine; Punnoose, Joshua; Chen, Steven; Petrillo, Christopher; Brown, Alisa; Munoz, Karina; Kitchen, Grant; Lam, Taylor; Bosemani, Thangamadhan; Huisman, Thierry A. G. M.; Allen, Robert H.; Acharya, Soumyadipta

    2016-01-01

    Head-tilt maneuver assists with achieving airway patency during resuscitation. However, the relationship between angle of head-tilt and airway patency has not been defined. Our objective was to define an optimal head-tilt position for airway patency in neonates (age: 0–28 days) and young infants (age: 29 days–4 months). We performed a retrospective study of head and neck magnetic resonance imaging (MRI) of neonates and infants to define the angle of head-tilt for airway patency. We excluded those with an artificial airway or an airway malformation. We defined head-tilt angle a priori as the angle between occipito-ophisthion line and ophisthion-C7 spinous process line on the sagittal MR images. We evaluated medical records for Hypoxic Ischemic Encephalopathy (HIE) and exposure to sedation during MRI. We analyzed MRI of head and neck regions of 63 children (53 neonates and 10 young infants). Of these 63 children, 17 had evidence of airway obstruction and 46 had a patent airway on MRI. Also, 16/63 had underlying HIE and 47/63 newborn infants had exposure to sedative medications during MRI. In spontaneously breathing and neurologically depressed newborn infants, the head-tilt angle (median ± SD) associated with patent airway (125.3° ± 11.9°) was significantly different from that of blocked airway (108.2° ± 17.1°) (Mann Whitney U-test, p = 0.0045). The logistic regression analysis showed that the proportion of patent airways progressively increased with an increasing head-tilt angle, with > 95% probability of a patent airway at head-tilt angle 144–150°. PMID:27003759

  16. Defining Optimal Head-Tilt Position of Resuscitation in Neonates and Young Infants Using Magnetic Resonance Imaging Data.

    PubMed

    Bhalala, Utpal S; Hemani, Malvi; Shah, Meehir; Kim, Barbara; Gu, Brian; Cruz, Angelo; Arunachalam, Priya; Tian, Elli; Yu, Christine; Punnoose, Joshua; Chen, Steven; Petrillo, Christopher; Brown, Alisa; Munoz, Karina; Kitchen, Grant; Lam, Taylor; Bosemani, Thangamadhan; Huisman, Thierry A G M; Allen, Robert H; Acharya, Soumyadipta

    2016-01-01

    Head-tilt maneuver assists with achieving airway patency during resuscitation. However, the relationship between angle of head-tilt and airway patency has not been defined. Our objective was to define an optimal head-tilt position for airway patency in neonates (age: 0-28 days) and young infants (age: 29 days-4 months). We performed a retrospective study of head and neck magnetic resonance imaging (MRI) of neonates and infants to define the angle of head-tilt for airway patency. We excluded those with an artificial airway or an airway malformation. We defined head-tilt angle a priori as the angle between occipito-ophisthion line and ophisthion-C7 spinous process line on the sagittal MR images. We evaluated medical records for Hypoxic Ischemic Encephalopathy (HIE) and exposure to sedation during MRI. We analyzed MRI of head and neck regions of 63 children (53 neonates and 10 young infants). Of these 63 children, 17 had evidence of airway obstruction and 46 had a patent airway on MRI. Also, 16/63 had underlying HIE and 47/63 newborn infants had exposure to sedative medications during MRI. In spontaneously breathing and neurologically depressed newborn infants, the head-tilt angle (median ± SD) associated with patent airway (125.3° ± 11.9°) was significantly different from that of blocked airway (108.2° ± 17.1°) (Mann Whitney U-test, p = 0.0045). The logistic regression analysis showed that the proportion of patent airways progressively increased with an increasing head-tilt angle, with > 95% probability of a patent airway at head-tilt angle 144-150°.

  17. Leptin promotes wound healing in the oral mucosa.

    PubMed

    Umeki, Hirochika; Tokuyama, Reiko; Ide, Shinji; Okubo, Mitsuru; Tadokoro, Susumu; Tezuka, Mitsuki; Tatehara, Seiko; Satomura, Kazuhito

    2014-01-01

    Leptin, a 16 kDa circulating anti-obesity hormone, exhibits many physiological properties. Recently, leptin was isolated from saliva; however, its function in the oral cavity is still unclear. In this study, we investigated the physiological role of leptin in the oral cavity by focusing on its effect on wound healing in the oral mucosa. Immunohistochemical analysis was used to examine the expression of the leptin receptor (Ob-R) in human/rabbit oral mucosa. To investigate the effect of leptin on wound healing in the oral mucosa, chemical wounds were created in rabbit oral mucosa, and leptin was topically administered to the wound. The process of wound repair was histologically observed and quantitatively analyzed by measuring the area of ulceration and the duration required for complete healing. The effect of leptin on the proliferation, differentiation and migration of human oral mucosal epithelial cells (RT7 cells) was investigated using crystal violet staining, reverse transcription polymerase chain reaction (RT-PCR) and a wound healing assay, respectively. Ob-R was expressed in spinous/granular cells in the epithelial tissue and vascular endothelial cells in the subepithelial connective tissue of the oral mucosa. Topical administration of leptin significantly promoted wound healing and shortened the duration required for complete healing. Histological analysis of gingival tissue beneath the ulceration showed a denser distribution of blood vessels in the leptin-treated group. Although the proliferation and differentiation of RT7 cells were not affected by leptin, the migration of these cells was accelerated in the presence of leptin. Topically administered leptin was shown to promote wound healing in the oral mucosa by accelerating epithelial cell migration and enhancing angiogenesis around the wounded area. These results strongly suggest that topical administration of leptin may be useful as a treatment to promote wound healing in the oral mucosa.

  18. Serotonergic mechanism of the relieving effect of bee venom acupuncture on oxaliplatin-induced neuropathic cold allodynia in rats.

    PubMed

    Lee, Ji-Hye; Li, Dong Xing; Yoon, Heera; Go, Donghyun; Quan, Fu Shi; Min, Byung-Il; Kim, Sun Kwang

    2014-12-06

    Oxaliplatin, an important chemotherapy drug for advanced colorectal cancer, often induces peripheral neuropathy, especially cold allodynia. Our previous study showed that bee venom acupuncture (BVA), which has been traditionally used in Korea to treat various pain symptoms, potently relieves oxaliplatin-induced cold allodynia in rats. However, the mechanism for this anti-allodynic effect of BVA remains poorly understood. We investigated whether and how the central serotonergic system, a well-known pathway for acupuncture analgesia, mediates the relieving effect of BVA on cold allodynia in oxaliplatin-injected rats. The behavioral signs of cold allodynia in Sprague-Dawley (SD) rats were induced by a single injection of oxaliplatin (6 mg/kg, i.p.). Before and after BVA treatment, the cold allodynia signs were evaluated by immersing the rat's tail into cold water (4°C) and measuring the withdrawal latency. For BVA treatment, a diluted BV (0.25 mg/kg) was subcutaneously administered into Yaoyangguan (GV3) acupoint, which is located between the spinous processes of the fourth and the fifth lumbar vertebra. Serotonin was depleted by a daily injection of DL-p-chlorophenylalanine (PCPA, 150 mg/kg, i.p.) for 3 days. The amount of serotonin in the spinal cord was measured by ELISA. Serotonergic receptor antagonists were administered intraperitoneally or intrathecally before BVA treatment. The serotonin levels in the spinal cord were significantly increased by BVA treatment and such increase was significantly reduced by PCPA. This PCPA pretreatment abolished the relieving effect of BVA on oxaliplatin-induced cold allodynia. Either of methysergide (mixed 5-HT1/5-HT2 receptor antagonist, 1 mg/kg, i.p.) or MDL-72222 (5-HT3 receptor antagonist, 1 mg/kg, i.p) blocked the anti-allodynic effect of BVA. Further, an intrathecal injection of MDL-72222 (12 μg) completely blocked the BVA-induced anti-allodynic action, whereas NAN-190 (5-HT1A receptor antagonist, 15 μg, i.t.) or ketanserin (5-HT2A receptor antagonist, 30 μg, i.t.) did not. These results suggest that BVA treatment alleviates oxaliplatin-induced acute cold allodynia in rats via activation of the serotonergic system, especially spinal 5-HT3 receptors. Thus, our findings may provide a clinically useful evidence for the application of BVA as an alternative therapeutic option for the management of peripheral neuropathy, a dose-limiting side effect that occurs after an administration of oxaliplatin.

  19. Construction and characterization of human oral mucosa equivalent using hyper-dry amniotic membrane as a matrix.

    PubMed

    Qi, Fangfang; Yoshida, Toshiko; Koike, Takeshi; Aizawa, Hitoshi; Shimane, Tetsu; Li, Yinghui; Yamada, Shinichi; Okabe, Motonori; Nikaido, Toshio; Kurita, Hiroshi

    2016-05-01

    Human amniotic membrane(HAM) as a graft material has been used in various fields. Hyper-dry amniotic membrane (HD-AM) is a novel dried amniotic membrane that is easy to handle and can be preserved at room temperature without time limitation. The purpose of this study was to investigate the useful properties of HD-AM in reconstruction of the oral mucosa. Human oral keratinocytes were isolated and seeded on HD-AM in serum-free culture system. Oral mucosa equivalent (OME) was developed and transplanted onto full-thickness wound on athymic mice. The wound healing was analyzed and the OME both before and after transplantation was analyzed with hematoxylin-eosin staining and immunohistochemical staining for Cytokines 10 (CK10), Cytokines 16 (CK16), and Ivolucrin (IVL). Oral keratinocytes spread and proliferated well on HD-AM. Two weeks after air-lifting, OME had formed with good differentiation and morphology. We confirmed immunohistochemically that the expression of CK10 was positive in all suprabasal layers, as was CK16 in the upper layers, while IVL was present in all cell layers. Three weeks after transplantation to athymic mice, the newly generated tissue had survived well with the smallest contraction. The epithelial cells of newly generated tissue expressed CK10 throughout in all suprabasal layers, IVL was mainly in the granular layer, and CK16 positive cells were observed in all spinous layer and granular layer but were not expressed in the mouse skin, all of which were similar to native gingival mucosa. The OME with HD-AM as a matrix revealed a good morphology and stable wound healing. This study demonstrates that HD-AM is a useful and feasible biomaterial for oral mucosa reconstruction. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Finite element investigation of the effect of a bifid arch on loading of the vertebral isthmus.

    PubMed

    Quah, Conal; Yeoman, Mark S; Cizinauskas, Andrius; Cooper, Kevin C; Peirce, Nick S; McNally, Donal S; Boszczyk, Bronek M

    2014-04-01

    The biomechanical effect of a bifid arch as seen in spina bifida occulta and following a midline laminectomy is poorly understood. To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Finite element analysis. Finite element model of an intact L4-S1 human lumbar motion segment including ligaments was used. A section of the L5 vertebral arch and spinous process was removed to create the model with a midline defect. The models were loaded axially to 1 kN and then combined with axial rotation of 3°. Bilateral stresses, alternating stresses, and shear fatigue failure on both models were assessed and compared. Under 1 kN axial load, the von Mises stresses observed in midline defect case and in the intact case were very similar (differences <5 MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1 kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the midline defect case (31 MPa) was much higher than the intact case (24.2 MPa), indicating a lack of load sharing across the vertebral arch in the midline defect case. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the midline defect case and 13.6 MPa for the intact case. From this, it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load and rotation conditions in the midline defect case, whereas for the intact case, fatigue failure will occur only after more than 10 million cycles. A bifid arch predisposes the isthmus to early fatigue fracture by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. New Optimal Needle Entry Angle for Cervical Transforaminal Epidural Steroid Injections: A Retrospective Study

    PubMed Central

    Karm, Myong-Hwan; Park, Jun Young; Kim, Doo Hwan; Cho, Hyun-Seok; Lee, Jae-Young; Kwon, Koo; Suh, Jeong Hun

    2017-01-01

    Objective: A cervical epidural steroid injection is one of the most commonly performed interventions to manage chronic neck pain and cervical radiculopathy. Despite its many severe complications, cervical transforaminal epidural steroid injection (CTFESI) is a clinically necessary modality for managing neck pain and cervical radiculopathy. We aimed in this study to find a safer optimal needle entry angle to decrease the chance of an accidental vertebral artery (VA) puncture even with a proper needle entry angle and to visualize the target of the needle tip. Methods: This retrospective study included 312 patients with neck pain or cervical radiculopathy who had undergone magnetic resonance imaging scans for diagnosis and treatment. The first line was drawn from the midpoint of the two articular pillars and passed through the exact midline of the spinous process. The second line was drawn parallel to the ventral lamina line (conventional transforaminal approach line, CTAL). The third line was drawn parallel to the ventral margin at the midpoint of the superior articular process's ventral border (new transforaminal approach line, NTAL). The angle of intersection between the midline and CTAL versus with NTAL were measured from both sides (right and left) at C5-6, C6-7, and C7-T1 levels. Also, the distance of CTAL and NTAL from VA were measured from both sides at each level. We examined whether the CTAL and NTAL would penetrate the ipsilateral VA, internal carotid artery (ICA), and internal jugular vein (IJV). Results: There were significant differences between CTAL and NTAL angles at all levels (P < 0.001). There were significant differences between the distance of CTAL and NTAL from VA at all levels (P < 0.001). There were also significant differences between the observed frequency of CTAL and NTAL that would penetrate the major ipsilateral vessel (VA, ICA, and IJV) on all levels and sides (P < 0.001~0.030). Conclusion: The angle of NTAL (approximately 70°) is safer than the angle of CTAL (approximately 50°) when considering vascular injuries to vessels, such as the VA, ICA, and IJV. PMID:28553170

  2. Measurement of segmental lumbar spine flexion and extension using ultrasound imaging.

    PubMed

    Chleboun, Gary S; Amway, Matthew J; Hill, Jesse G; Root, Kara J; Murray, Hugh C; Sergeev, Alexander V

    2012-10-01

    Clinical measurement, technical note. To describe a technique to measure interspinous process distance using ultrasound (US) imaging, to assess the reliability of the technique, and to compare the US imaging measurements to magnetic resonance imaging (MRI) measurements in 3 different positions of the lumbar spine. Segmental spinal motion has been assessed using various imaging techniques, as well as surgically inserted pins. However, some imaging techniques are costly (MRI) and some require ionizing radiation (radiographs and fluoroscopy), and surgical procedures have limited use because of the invasive nature of the technique. Therefore, it is important to have an easily accessible and inexpensive technique for measuring lumbar segmental motion to more fully understand spine motion in vivo, to evaluate the changes that occur with various interventions, and to be able to accurately relate the changes in symptoms to changes in motion of individual vertebral segments. Six asymptomatic subjects participated. The distance between spinous processes at each lumbar segment (L1-2, L2-3, L3-4, L4-5) was measured digitally using MRI and US imaging. The interspinous distance was measured with subjects supine and the lumbar spine in 3 different positions (resting, lumbar flexion, and lumbar extension) for both MRI and US imaging. The differences in distance from neutral to extension, neutral to flexion, and extension to flexion were calculated. The measurement methods had excellent reliability for US imaging (intraclass correlation coefficient [ICC3,3] = 0.94; 95% confidence interval: 0.85, 0.97) and MRI (ICC3,3 = 0.98; 95% confidence interval: 0.95, 0.99). The distance measured was similar between US imaging and MRI (P>.05), except at L3-4 flexion-extension (P = .003). On average, the MRI measurements were 1.3 mm greater than the US imaging measurements. This study describes a new method for the measurement of lumbar spine segmental flexion and extension motion using US imaging. The US method may offer an alternative to other imaging techniques to monitor clinical outcomes because of its ease of use and the consistency of measurements compared to MRI.

  3. Correlation between pollen morphology and pollination mechanisms in the Hydrocharitaceae.

    PubMed

    Tanaka, Norio; Uehara, Koichi; Murata, Jin

    2004-08-01

    The pollen morphology of 11 genera and 11 species of the Hydrocharitaceae and one species of the Najadaceae was studied using scanning and transmission electron microscopies, and the exine structures and sculptures are discussed in relation to pollination mechanisms and the molecular phylogeny. The pollen grains of the Hydrocharitaceae are spherical, inaperturate, and form monads or tetrads, while those of the Najadaceae are elliptical, inaperturate, and form monads. The entomophilous genera Egeria, Blyxa, Ottelia, Stratiotes, and Hydrocharis share pollen grains that have projections like spines or bacula. The anemophilous genus Limnobium has reticulate pollen grains. The hypohydrophilous genera Thalassia and Najas are characterized by pollen grains with reduced exine structures. The pollen-epihydrophilous genera Elodea and Hydrilla have tightly arranged small spinous pollen grains, and the male flower-epihydrophilous genera Enhalus and Vallisneria have reduced reticulate or gemmate exines. Character state reconstruction of the exine structures and sculptures using a molecular phylogenetic tree suggests that variation in the exine is generally correlated with the pollination mechanism; the selective pressures acting on the pollination mechanisms have reduced the exine structure in hypohydrophilous plants and resulted in various exine sculptures that are adapted to the different pollination mechanisms in entomophilous, anemophilous, and pollen-epihydrophilous plants.

  4. Alternative classification and screening protocol for transitional lumbosacral vertebra in German shepherd dogs

    PubMed Central

    2012-01-01

    Background Lumbosacral transitional vertebra (LTV) is a common congenital and hereditary anomaly in many dog breeds. It predisposes to premature degeneration of the lumbosacral junction, and is a frequent cause of cauda equina syndrome, especially in German shepherd dogs. Ventrodorsal hip radiographs are most often used in diagnosis of LTV in screening programs. In this study, value of laterolateral lumbar spine radiographs as additions to ventrodorsal radiographs in diagnosis of LTV, and characteristics of LTV and the eighth lumbar vertebra (L8) in laterolateral radiographs were studied. Additionally, computed tomography (CT) features of different types of LTV were elucidated. Methods The ventrodorsal pelvic and laterolateral lumbar spine radiographs of 228 German shepherd dogs were evaluated for existence and type of LTV. Morphology of transverse processes was used in classification of LTV in ventrodorsal radiographs. The relative length of sixth (L6) and seventh (L7) vertebrae (L6/L7) was used in characterization of these vertebrae in laterolateral radiographs. CT studies were available for 16 dogs, and they were used for more detailed characterization of different types of LTV. Non-parametric χ2 statistics, generalized logit model for multinomial data, and one-way analysis of variance was used for statistical analyses. Results In all, 92 (40%) dogs had a LTV, the most common type being separation of first spinous process from the median crest of the sacrum in 62 dogs (67% of LTV). Eight dogs had eight lumbar vertebrae. Those dogs with LTV had longer L7 in relation to L6 than dogs with normal lumbosacral junctions. When L6/L7 decreased by 0.1 units, the proportion of dogs belonging to the group with L8 was 14-fold higher than in the group with normal lumbosacral junctions. L8 resembled first sacral vertebra (S1) in length and position and was therefore classified as one type of LTV. With CT it was shown that categorizing LTV, based on shape and visibility of transverse processes seen in ventrodorsal radiographs, could be misleading. Conclusions We suggest that L8 be included as a part of the LTV complex, and the laterolateral radiographs of the lumbar spine be considered as an addition to ventrodorsal projections in the screening protocols for LTV. PMID:22549019

  5. Epidural application of spinal instrumentation particulate wear debris: a comprehensive evaluation of neurotoxicity using an in vivo animal model.

    PubMed

    Cunningham, Bryan W; Hallab, Nadim J; Hu, Nianbin; McAfee, Paul C

    2013-09-01

    The introduction and utilization of motion-preserving implant systems for spinal reconstruction served as the impetus for this basic scientific investigation. The effect of unintended wear particulate debris resulting from micromotion at spinal implant interconnections and bearing surfaces remains a clinical concern. Using an in vivo rabbit model, the current study quantified the neural and systemic histopathological responses following epidural application of 11 different types of medical-grade particulate wear debris produced from spinal instrumentation. A total of 120 New Zealand White rabbits were equally randomized into 12 groups based on implant treatment: 1) sham (control), 2) stainless steel, 3) titanium alloy, 4) cobalt chromium alloy, 5) ultra-high molecular weight polyethylene (UHMWPe), 6) ceramic, 7) polytetrafluoroethylene, 8) polycarbonate urethane, 9) silicone, 10) polyethylene terephthalate, 11) polyester, and 12) polyetheretherketone. The surgical procedure consisted of a midline posterior approach followed by resection of the L-6 spinous process and L5-6 ligamentum flavum, permitting interlaminar exposure of the dural sac. Four milligrams of the appropriate treatment material (Groups 2-12) was then implanted onto the dura in a dry, sterile format. All particles (average size range 0.1-50 μm in diameter) were verified to be endotoxin free prior to implantation. Five animals from each treatment group were sacrificed at 3 months and 5 were sacrificed at 6 months postoperatively. Postmortem analysis included epidural cultures and histopathological assessment of local and systemic tissue samples. Immunocytochemical analysis of the spinal cord and overlying epidural fibrosis quantified the extent of proinflammatory cytokines (tumor necrosis factor-α, tumor necrosis factor-β, interleukin [IL]-1α, IL-1β, and IL-6) and activated macrophages. Epidural cultures were negative for nearly all cases, and there was no evidence of particulate debris or significant histopathological changes in the systemic tissues. Gross histopathological examination demonstrated increased levels of epidural fibrosis in the experimental treatment groups compared with the control group. Histopathological evaluation of the epidural fibrous tissues showed evidence of a histiocytic reaction containing phagocytized inert particles and foci of local inflammatory reactions. At 3 months, immunohistochemical examination of the spinal cord and epidural tissues demonstrated upregulation of IL-6 in the groups in which metallic and UHMWPe debris were implanted (p < 0.05), while macrophage activity levels were greatest in the stainless-steel and UHMWPe groups (p < 0.05). By 6 months, the levels of activated cytokines and macrophages in nearly all experimental cases were downregulated and not significantly different from those of the operative controls (p > 0.05). The spinal cord had no evidence of lesions or neuropathology. However, multiple treatments in the metallic groups exhibited a mild, chronic macrophage response to particulate debris, which had diffused intrathecally. Epidural application of spinal instrumentation particulate wear debris elicits a chronic histiocytic reaction localized primarily within the epidural fibrosis. Particles have the capacity to diffuse intrathecally, eliciting a transient upregulation in macrophage/cytokine activity response within the epidural fibrosis. Overall, based on the time periods evaluated, there was no evidence of an acute neural or systemic histopathological response to the materials included in the current project.

  6. Evaluation of Galvanic Vestibular Stimulation System

    NASA Technical Reports Server (NTRS)

    Kofman, I. S.; Warren, E.; DeSoto, R.; Moroney, G.; Chastain, J.; De Dios, Y. E.; Gadd, N.; Taylor, L.; Peters, B. T.; Allen, E.; hide

    2017-01-01

    Microgravity exposure results in an adaptive central reinterpretation of information from multiple sensory sources to produce a sensorimotor state appropriate for motor actions in this unique environment, but this new adaptive state is no longer appropriate for the 1-g gravitational environment on Earth. During these gravitational transitions, astronauts experience deficits in both perceptual and motor functions including impaired postural control, disruption in spatial orientation, impaired control of locomotion that include alterations in muscle activation variability, modified lower limb kinematics, alterations in head-trunk coordination as well as reduced dynamic visual acuity. Post-flight changes in postural and locomotor control might have adverse consequences if a rapid egress was required following a long-duration mission, where support personnel may not be available to aid crewmembers. The act of emergency egress includes, but is not limited to standing, walking, climbing a ladder, jumping down, monitoring displays, actuating discrete controls, operating auxiliary equipment, and communicating with Mission Control and recovery teams while maintaining spatial orientation, mobility and postural stability in order to escape safely. The average time to recover impaired postural control and functional mobility to preflight levels of performance has been shown to be approximately two weeks after long-duration spaceflight. The postflight alterations are due in part to central reinterpretation of vestibular information caused by exposure to microgravity. In this study we will use a commonly used technique of transcutaneous electrical stimulation applied across the vestibular end organs (galvanic vestibular stimulation, GVS) to disrupt vestibular function as a simulation of post-flight disturbances. The goal of this project is an engineering human-in-the-loop evaluation of a device that can degrade performance of functional tasks (e.g. to maintain upright balance) similar to what astronauts experience during transitions to new gravitational environments. Stochastic electrical stimulation can be applied to the vestibular system through electrodes placed over the mastoid process behind the ears in the binaural configuration resulting in stimulation in the mediolateral (side-to-side) plane. An additional electrode can be placed over the bony landmark of the tip of the c7 spinous process for the double monaural configuration, which will cause stimulation in the anteroposterior (forward-backward) plane. A portable constant current bipolar stimulator with subject isolation was designed and built to deliver the stimulus. The unit is powered using a 3.7 V battery pack and designed to produce currents up to 5 mA. The stimulator, controlled by a Raspberry Pi 3 computer, offers several stimulus signal generation options including a standalone mode, which uses onboard signal files stored on the flash memory card. Stochastic stimulation signals will be generated in 0-30 Hz frequency bandwidth. Stimulation amplitude can be increased incrementally to a maximum amplitude of 5.0 mA (e.g., 0, 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 mA). In control trials, subjects will be experiencing vestibular stimulation with 0-mA current applied through the electrodes. The system will be evaluated at various levels of stimulation and in both the binaural and double monaural electrode configurations. One of the objectives is to identify stimulation levels producing effects most comparable to the post-flight disturbances. This is a pilot study that will set the stage for a larger, more comprehensive study that will investigate wider aspects of post-flight sensorimotor dysfunction and set sensorimotor standards for crew health.

  7. Endobiliary Stent Position Changes during External-beam Radiotherapy

    PubMed Central

    Chu, Kwun-Ye; Eccles, Cynthia L.; Brunner, Thomas B.

    2015-01-01

    Purpose Endobiliary stents can be used as surrogates for pancreatic localization when using cone-beam computed tomography (CBCT) during external-beam radiotherapy (EBRT). This work reports on interfraction stent position changes during EBRT for locally advanced pancreatic cancer (LAPC). Materials and Methods Six patients with endobiliary stents who underwent EBRT for LAPC were assessed. Measurements from the most superior aspect of the stent (sup stent) and the most inferior aspect of the stent (inf stent) to the most inferior, posterior aspect of the L1 vertebra central spinous process were determined from daily treatment CBCTs and compared with those determined from the planning computed tomography (CT) scan. Changes in stent-L1 measurements were interpreted as changes in relative stent position. Results Three patients showed mean interfraction stent position changes of ≥1 cm when treatment measurements were compared with planning measurements. The sup stent for patient A moved to the right (2.66 ± 2.77 cm) and inferiorly (3.0 ± 3.12 cm), and the inf stent moved to the right (1.92 ± 2.02 cm) inferiorly (3.23 ± 3.34 cm) and posteriorly (1.41 ± 1.43 cm). The inf stent for patient B moved superiorly (2.23 ± 0.49 cm) and posteriorly (1.72 ± 0.59 cm). The sup and inf stent for patient F moved inferiorly (0.98 ± 0.35 cm and 1.21 ± 0.38 cm, respectively). The remaining three patients C, D, and E showed interfraction position changes of <1 cm. Conclusion Endobiliary stent migration and deformation were observed in a small subset of patients. Further investigation is required before confirming their use as surrogates for LAPC target localization during image-guided EBRT. PMID:26090069

  8. Scapular Resting Position and Gleno-Humeral Movement Dysfunction in Asymptomatic Racquet Players: A Case-Control Study

    PubMed Central

    Shimpi, Apurv P.; Bhakti, Shah; Roshni, Karnik; Rairikar, Savita A.; Shyam, Ashok; Sancheti, Parag K.

    2015-01-01

    Background: Racquet sports, especially lawn tennis and badminton have been gaining popularity in Asian countries like India. With this increase in popularity, the injury rate in the sport has also increased. Objectives: The study will help detect the presence of gleno-humeral movement dysfunction and scapular resting position abnormality in asymptomatic racquet players, thus providing basis for screening the players and allow the clinician to determine if the asymmetry is a normal adaptation in the player or an abnormal change associated with injury. Materials and Methods: 46 asymptomatic professional players were divided into a study group of 23 players (16 tennis and 7 badminton) and control group of 23 football players. Assessment of passive gleno-humeral range of motion and distance of spine and inferior angle of scapula from corresponding spinous process were measured bilaterally and between groups. Results: There was statistically significant reduction in range of internal rotation (62.17 ± 8.09), extension (39.78 ± 4.12) and an increase in the external rotation (106.95 ± 7.49) of dominant compared to non-dominant arm of racquet players and a statistically significant decrease in internal rotation (78.69 ± 10.24), extension (44.78 ± 3.19), adduction (37.39 ± 6.54) and an increase in external rotation (102.6 ± 5.19) of dominant arm of racquet players compared to football players. Study also showed statistically significant increase in the spino-scapular distance at the level of inferior angle of scapula (10.23 ± 1.43) on dominant side compared to non-dominant. Conclusions: The dominant side scapula of asymptomatic racquet players showed increased external rotation and elevation as compared to the non-dominant side. Also, reduced shoulder internal rotation, extension and adduction and gain in shoulder external rotation was observed on the dominant side of racquet players when compared to the control group. PMID:26715968

  9. Scapular Resting Position and Gleno-Humeral Movement Dysfunction in Asymptomatic Racquet Players: A Case-Control Study.

    PubMed

    Shimpi, Apurv P; Bhakti, Shah; Roshni, Karnik; Rairikar, Savita A; Shyam, Ashok; Sancheti, Parag K

    2015-12-01

    Racquet sports, especially lawn tennis and badminton have been gaining popularity in Asian countries like India. With this increase in popularity, the injury rate in the sport has also increased. The study will help detect the presence of gleno-humeral movement dysfunction and scapular resting position abnormality in asymptomatic racquet players, thus providing basis for screening the players and allow the clinician to determine if the asymmetry is a normal adaptation in the player or an abnormal change associated with injury. 46 asymptomatic professional players were divided into a study group of 23 players (16 tennis and 7 badminton) and control group of 23 football players. Assessment of passive gleno-humeral range of motion and distance of spine and inferior angle of scapula from corresponding spinous process were measured bilaterally and between groups. There was statistically significant reduction in range of internal rotation (62.17 ± 8.09), extension (39.78 ± 4.12) and an increase in the external rotation (106.95 ± 7.49) of dominant compared to non-dominant arm of racquet players and a statistically significant decrease in internal rotation (78.69 ± 10.24), extension (44.78 ± 3.19), adduction (37.39 ± 6.54) and an increase in external rotation (102.6 ± 5.19) of dominant arm of racquet players compared to football players. Study also showed statistically significant increase in the spino-scapular distance at the level of inferior angle of scapula (10.23 ± 1.43) on dominant side compared to non-dominant. The dominant side scapula of asymptomatic racquet players showed increased external rotation and elevation as compared to the non-dominant side. Also, reduced shoulder internal rotation, extension and adduction and gain in shoulder external rotation was observed on the dominant side of racquet players when compared to the control group.

  10. The influence of body mass and thoracic dimensions on arterial oxygenation in anaesthetized horses and ponies.

    PubMed

    Mansel, Juliet C; Clutton, R Eddie

    2008-09-01

    To examine the relationship between body mass and thoracic dimensions on arterial oxygen tensions (PaO(2)) in anaesthetized horses and ponies positioned in dorsal recumbency. Prospective clinical study. Thirty six client-owned horses and ponies, mean [+/-SD (range)] age 8.1 +/- 4.8 (1.5-20) years and mean body mass 467 +/- 115 (203-656) kg. Before general anaesthesia, food and water were withheld for 12 and 1 hours respectively. Body mass (kg), height at the withers (H), thoracic circumference (C), thoracic depth (length between dorsal spinous process and sternum; D), thoracic width (between point of shoulders; W), and thoracic diagonal length (point of shoulder to last rib; L) were measured. Pre-anaesthetic medication was with intravenous (IV) romifidine (0.1 mg kg(-1)). Anaesthesia was induced with an IV ketamine (2.2 mg kg(-1)) and diazepam (0.05 mg kg(-1)) combination and maintained with halothane in 1:1 oxygen:nitrous oxide (N(2)O) mixture. Animals were positioned in dorsal recumbency and allowed to breathe spontaneously. Nitrous oxide was discontinued after 10 minutes, and arterial blood samples obtained and analysed for gas tensions at 15, 30 and 60 minutes after connection to the anaesthetic breathing circuit. Data were analysed using anova and Pearson's correlation co-efficient. The height per unit body mass (H kg(-1)) and thoracic circumference per unit body mass (C kg(-1)) correlated strongly (r = 0.85, p < 0.001 and r = 0.82, p < 0.001 respectively) with arterial oxygen tensions (PaO(2)) at 15 minutes. There is a strong positive correlation between H kg(-1) and C kg(-1) and PaO(2) after 15 minutes of anaesthesia in halothane-anaesthetized horses positioned in dorsal recumbency. Readily obtained linear measurements (height and thoracic circumference) and body mass may be used to predict the ability of horses to oxygenate during anaesthesia.

  11. Variability amongst radiographers in the categorization of clinical acceptability for digital trauma radiography

    NASA Astrophysics Data System (ADS)

    Decoster, Robin; Toomey, Rachel; Smits, Dirk; Mol, Harrie; Verhelle, Filip; Butler, Marie-Louise

    2016-03-01

    Introduction: Radiographers evaluate anatomical structures to judge clinical acceptability of a radiograph. Whether a radiograph is deemed acceptable for diagnosis or not depends on the individual decision of the radiographer. Individual decisions cause variation in the accepted image quality. To minimise these variations definitions of acceptability, such as in RadLex, were developed. On which criteria radiographers attribute a RadLex categories to radiographs is unknown. Insight into these criteria helps to further optimise definitions and reduce variability in acceptance between radiographers. Therefore, this work aims the evaluation of the correlation between the RadLex classification and the evaluation of anatomical structures, using a Visual Grading Analysis (VGA) Methods: Four radiographers evaluated the visibility of five anatomical structures of 25 lateral cervical spine radiographs on a secondary class display with a VGA. They judged clinical acceptability of each radiograph using RadLex. Relations between VGAS and RadLex category were analysed with Kendall's Tau correlation and Nagelkerke pseudo-R². Results: The overall VGA score (VGAS) and the RadLex score correlate (rτ= 0.62, p<0.01, R2=0.72) strongly. The observers' evaluation of contrast between bone, air (trachea) and soft tissue has low value in predicting (rτ=0.55, p<0.01, R2=0.03) the RadLex score. The reproduction of spinous processes (rτ=0.67, p<0.01, R2=0.31) and the evaluation of the exposure (rτ=0.65, p<0.01, R2=0.56) have a strong correlation with high predictive value for the RadLex score. Conclusion: RadLex scores and VGAS correlate positively, strongly and significantly. The predictive value of bony structures may support the use of these in the judgement of clinical acceptability. Considerable inter-observer variations in the VGAS within a certain RadLex category, suggest that observers use of observer specific cut-off values.

  12. [Treatment of Occipital Neuralgia by Electroacupuncture Combined with Neural Mobilization].

    PubMed

    Wang, Yan; Guo, Zi-Nan; Yang, Zhen; Wang, Shun

    2018-03-25

    To observe the effect of electroacupuncture (EA) combined with neural mobilization (NM) in the treatment of occipital neuralgia. A total of 62 occipital neuralgia patients were randomized into EA group (19 cases), NM group (22 cases) and EA+NM group (21 cases). EA was applied at acupoint-pairs as Yuzhen (BL 9)- Tianzhu (BL 10), Fengchi (GB 20)- Wangu (GB 12), etc. NM intervention consisted of occipital muscle group mobilization, C 2 spinous process mobilization, cervical joint passive movement management mobilization, etc., was performed at the impaired cervical spine segment. The two methods were used in combination for patients in the EA+NM group. All the treatment was given once a day for 2 weeks. Before and after treatment, the visual analogue scale (VAS) and the 6-point (1-6 points) behavioral rating scale (BRS-6) of headache were used to assess the severity of pain. The therapeutic effect was evaluated according to the "Criteria for Diagnosis and Cure-Improvement of Clinical Conditions" formulated by State Administration of Traditional Chinese Medicine of the People's Republic of China in 1994. After treatment, both VAS and BRS-6 scores were significantly lower than those before treatment in each of the three groups ( P <0.05), and were significantly lower in the EA+NM group than in the simple EA and simple NM groups ( P <0.01, P <0.05). The total effective rates were 78.95% (15/19) in the EA group, 68.18% (15/22) in the NM group, and 90.48% (19/21) in the EA+NM group, with an obviously better therapeutic effect being in the EA+NM group relevant to each of the other two treatment groups ( P <0.05). EA, NM and EA combined with NM can improve symptoms of patients with occipital neuralgia, and EA+NM has a synergic analgesic effect for occipital neuralgia.

  13. Anatomy and biomechanics of the vertebral aponeurosis part of the posterior layer of the thoracolumbar fascia.

    PubMed

    Loukas, Marios; Shoja, Mohammadali M; Thurston, Todd; Jones, Virginia L; Linganna, Sanjay; Tubbs, R Shane

    2008-03-01

    There is significant paucity in the literature regarding vertebral aponeurosis. We were able to find only a few descriptions of this specific fascia in the extant medical literature. To elucidate further the anatomy of this structure, forty adult human cadavers were dissected. Both quantitation and anatomical observations were made of the vertebral aponeurosis. The vertebral aponeurosis was identified in 100% of specimens. This fascia was identified as a thin fibrous layer consisting of longitudinal and transverse connective tissue fibers blended together deep to the latissimus dorsi muscle. It attached medially to the spinous processes of the of the thoracic vertebrae; laterally to the angles of ribs; inferiorly to the fascia covering the serratus posterior inferior muscle (superficial lamina of the posterior layer of thoracolumbar fascia); superiorly it ran deep to the serratus posterior superior and splenius capitis muscles to blend with the deep fascia of the neck. At the level of the serratus posterior inferior muscle, the vertebral aponeurosis fused to form a continuous layer descending toward the sacrotuberous ligament covering the erector spinae muscle. Morphometrically, the mean length of the vertebral aponeurosis was 38 cm and the mean width was 24 cm. The mean thickness was three mm. There was no significant difference between left and right sides, gender or age with regard to vertebral aponeurosis length, width, or thickness (P > 0.05). During manual tension of the vertebral aponeurosis, the tensile force necessary for failure had a mean of 38.7 N. In all specimens, the vertebral aponeurosis was capable of holding sutures placed through its substance. We hope that these data will be of use for descriptive purposes and may potentially add to our understanding of the biomechanics involved in movements of the back. As back pain is perhaps the most common reason patients visit their physicians, additional knowledge of this anatomical region is important.

  14. Sagittal Plane Correction Using the Lateral Transpsoas Approach: A Biomechanical Study on the Effect of Cage Angle and Surgical Technique on Segmental Lordosis.

    PubMed

    Melikian, Rojeh; Yoon, Sangwook Tim; Kim, Jin Young; Park, Kun Young; Yoon, Caroline; Hutton, William

    2016-09-01

    Cadaveric biomechanical study. To determine the degree of segmental correction that can be achieved through lateral transpsoas approach by varying cage angle and adding anterior longitudinal ligament (ALL) release and posterior element resection. Lordotic cage insertion through the lateral transpsoas approach is being used increasingly for restoration of sagittal alignment. However, the degree of correction achieved by varying cage angle and ALL release and posterior element resection is not well defined. Thirteen lumbar motion segments between L1 and L5 were dissected into single motion segments. Segmental angles and disk heights were measured under both 50 N and 500 N compressive loads under the following conditions: intact specimen, discectomy (collapsed disk simulation), insertion of parallel cage, 10° cage, 30° cage with ALL release, 30° cage with ALL release and spinous process (SP) resection, 30° cage with ALL release, SP resection, facetectomy, and compression with pedicle screws. Segmental lordosis was not increased by either parallel or 10° cages as compared with intact disks, and contributed small amounts of lordosis when compared with the collapsed disk condition. Placement of 30° cages with ALL release increased segmental lordosis by 10.5°. Adding SP resection increased lordosis to 12.4°. Facetectomy and compression with pedicle screws further increased lordosis to approximately 26°. No interventions resulted in a decrease in either anterior or posterior disk height. Insertion of a parallel or 10° cage has little effect on lordosis. A 30° cage insertion with ALL release resulted in a modest increase in lordosis (10.5°). The addition of SP resection and facetectomy was needed to obtain a larger amount of correction (26°). None of the cages, including the 30° lordotic cage, caused a decrease in posterior disk height suggesting hyperlordotic cages do not cause foraminal stenosis. N/A.

  15. Dorsal laminectomy for treatment of cervical vertebral stenotic myelopathy in an alpaca.

    PubMed

    Barker, W H J; Witte, T H; Driver, C J; Jull, P; Whitehead, C E; Volk, H A

    2015-05-15

    An 11-year-old male breeding alpaca was evaluated for a 2-day history of lowered head carriage and lethargy. On initial examination, the alpaca had signs of lethargy and lowered carriage of the head and neck, but no specific neurologic deficits. Medical management improved the clinical signs, but 8 months later, the alpaca developed acute, progressive general proprioceptive ataxia affecting all 4 limbs and was referred for further evaluation and treatment. Magnetic resonance imaging and CT identified disruption of the normal osseous architecture of C7 and T1. Medical management was attempted, but because of a lack of improvement, the patient underwent surgery 14 months after initial examination. A dorsal laminectomy of C7 and T1 via a dorsal midline approach was performed, and the spinous processes of both vertebrae were removed prior to removal of the overlying lamina. Free dorsal expansion of the spinal cord was ensured by resection of the ligamentum flavum. Six months after surgery, the alpaca had returned to successful breeding with 7 hembra bred in the first year after surgery, producing 6 crias, and 4 crias in the second year. The patient was eventually euthanized 28 months after surgery because of neurologic deterioration but was still ambulatory at that time. A good outcome with adequate alleviation of clinical signs and breeding soundness for > 2 years following dorsal laminectomy was achieved in this camelid patient. The surgical approach was similar to that in other species and was associated with mild postoperative morbidity. Veterinarians treating camelids should be aware of the initial clinical signs and treatment options for cervical vertebral stenotic myelopathy. In acute cases, the signs of reduced cervical mobility and pain on manipulation should prompt investigation including appropriate diagnostic imaging. Timely surgical intervention should be considered in patients that respond poorly to medical treatment to avoid irreversible spinal cord injury and optimize outcome.

  16. International Spine Radiosurgery Consortium Consensus Guidelines for Target Volume Definition in Spinal Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Brett W., E-mail: coxb@mskcc.org; Spratt, Daniel E.; Lovelock, Michael

    2012-08-01

    Purpose: Spinal stereotactic radiosurgery (SRS) is increasingly used to manage spinal metastases. However, target volume definition varies considerably and no consensus target volume guidelines exist. This study proposes consensus target volume definitions using common scenarios in metastatic spine radiosurgery. Methods and Materials: Seven radiation oncologists and 3 neurological surgeons with spinal radiosurgery expertise independently contoured target and critical normal structures for 10 cases representing common scenarios in metastatic spine radiosurgery. Each set of volumes was imported into the Computational Environment for Radiotherapy Research. Quantitative analysis was performed using an expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE)more » with kappa statistics calculating agreement between physicians. Optimized confidence level consensus contours were identified using histogram agreement analysis and characterized to create target volume definition guidelines. Results: Mean STAPLE agreement sensitivity and specificity was 0.76 (range, 0.67-0.84) and 0.97 (range, 0.94-0.99), respectively, for gross tumor volume (GTV) and 0.79 (range, 0.66-0.91) and 0.96 (range, 0.92-0.98), respectively, for clinical target volume (CTV). Mean kappa agreement was 0.65 (range, 0.54-0.79) for GTV and 0.64 (range, 0.54-0.82) for CTV (P<.01 for GTV and CTV in all cases). STAPLE histogram agreement analysis identified optimal consensus contours (80% confidence limit). Consensus recommendations include that the CTV should include abnormal marrow signal suspicious for microscopic invasion and an adjacent normal bony expansion to account for subclinical tumor spread in the marrow space. No epidural CTV expansion is recommended without epidural disease, and circumferential CTVs encircling the cord should be used only when the vertebral body, bilateral pedicles/lamina, and spinous process are all involved or there is extensive metastatic disease along the circumference of the epidural space. Conclusions: This report provides consensus guidelines for target volume definition for spinal metastases receiving upfront SRS in common clinical situations.« less

  17. Remodelling of three-dimensional organization of the nucleus during terminal keratinocyte differentiation in the epidermis

    PubMed Central

    Gdula, Michal R.; Poterlowicz, Krzysztof; Mardaryev, Andrei N.; Sharov, Andrey A.; Peng, Y.; Fessing, Michael Y.; Botchkarev, Vladimir A.

    2014-01-01

    The nucleus of epidermal keratinocytes is a complex and highly compartmentalized organelle, whose structure is markedly changed during terminal differentiation and transition of the genome from a transcriptionally active state seen in the basal and spinous epidermal cells to a fully inactive state in the keratinized cells of the cornified layer. Here, using multi-color confocal microscopy, followed by computational image analysis and mathematical modelling, we demonstrate that in normal mouse foot-pad epidermis transition of keratinocytes from basal epidermal layer to the granular layer is accompanied by marked differences in nuclear architecture and micro-environment including: i) decrease of the nuclear volume, ii) decrease in expression of the markers of transcriptionally-active chromatin; iii) internalization and decrease in the number of nucleoli; iv) increase in the number of pericentromeric heterochromatic clusters; v) increase in the frequency of associations between pericentromeric clusters, chromosomal territory 3, and nucleoli. These data suggest a role for nucleoli and pericentromeric heterochromatin clusters as organizers of nuclear micro-environment required for proper execution of gene expression programs in differentiating keratinocytes and provide important background information for further analyses of alterations in the topological genome organization seen in pathological skin conditions including disorders of epidermal differentiation and epidermal tumors. PMID:23407401

  18. A new genus and species of Macroderoididae, and other digeneans from fishes of Lake Malawi, Africa.

    PubMed

    Bray, Rodney A; Hendrix, Sherman S

    2007-08-01

    Malawitrema staufferi n. gen., n. sp., an unusual digenean, is described from Clarias mossambicus (type host) and Bagrus meridionalis from Lake Malawi. It has a small, pyriform body, with a spinous tegument. The ceca are relative short, not reaching to the testes. The 2 testes are symmetrical in the middle hind body. The cirrus sac is long and narrow, reaching into hind body. The genital pore is median, immediately anterior to the ventral sucker. The ovary is pretesticular, and a canalicular seminal vesicle and Laurer's canal are present. The uterus usually reaches distinctly posteriorly to testes. The eggs are small. The follicular vitellarium is in 2 small fields just anterior to testes. The ventrally subterminal excretory pore leads to a claviform vesicle. This species does not fit clearly into any known family of digeneans and is placed in the Macroderoididae as a temporary measure. Other digeneans reported from Lake Malawi include Haplorchoides cahirinus (Looss, 1896) in C. mossambicus and B. meridionalis; Astiotrema turneri Bray, van Oosterhout, Blais & Cable, 2006 in Protomelas annectens, P. cf. taeniolatus, Labeotropheus fuelleborni, Ctenopharynx (Otopharynx) pictus, and Pseudotropheus zebra; Glossidium pedatum Looss, 1899 in C. mossambicus and B. meridionalis; and an unidentifiable sanguinicolid from Bathyclarias nyasensis.

  19. Unusual presentation of cactus spines in the flank of an elderly man: a case report

    PubMed Central

    2010-01-01

    Introduction Splinters and spines of plant matter are common foreign bodies in skin wounds of the extremities, and often present embedded in the dermis or subcutaneous tissue. Vegetative foreign bodies are highly inflammatory and, if not completely removed, can cause infection, toxic reactions, or granuloma formation. Older patients are at increased risk for infection from untreated plant foreign bodies. The most common error in plant splinter and spine management is failure to detect their presence. Case presentation Here we report a case of cactus spines in an 84-year-old Caucasian man presenting on the right flank as multiple, red papules with spiny extensions. This presentation was unusual both in location and the spinous character of the lesions, and only after punch biopsy analysis was a diagnosis of cactus matter spines made. Conclusions Our patient presented with an unusual case of cactus spines that required histopathology for identification. Skin lesions with neglected foreign bodies are a common cause of malpractice claims. If not removed, foreign bodies of the skin, particularly in elderly individuals, can result in inflammatory and infectious sequela. This report underscores the importance of thoroughly evaluating penetrating skin lesions for the presence of foreign bodies, such as splinters and spines. PMID:20500838

  20. Human Keratinocyte Growth and Differentiation on Acellular Porcine Dermal Matrix in relation to Wound Healing Potential

    PubMed Central

    Zajicek, Robert; Mandys, Vaclav; Mestak, Ondrej; Sevcik, Jan; Königova, Radana; Matouskova, Eva

    2012-01-01

    A number of implantable biomaterials derived from animal tissues are now used in modern surgery. Xe-Derma is a dry, sterile, acellular porcine dermis. It has a remarkable healing effect on burns and other wounds. Our hypothesis was that the natural biological structure of Xe-Derma plays an important role in keratinocyte proliferation and formation of epidermal architecture in vitro as well as in vivo. The bioactivity of Xe-Derma was studied by a cell culture assay. We analyzed growth and differentiation of human keratinocytes cultured in vitro on Xe-Derma, and we compared the results with formation of neoepidermis in the deep dermal wounds treated with Xe-Derma. Keratinocytes cultured on Xe-Derma submerged in the culture medium achieved confluence in 7–10 days. After lifting the cultures to the air-liquid interface, the keratinocytes were stratified and differentiated within one week, forming an epidermis with basal, spinous, granular, and stratum corneum layers. Immunohistochemical detection of high-molecular weight cytokeratins (HMW CKs), CD29, p63, and involucrin confirmed the similarity of organization and differentiation of the cultured epidermal cells to the normal epidermis. The results suggest that the firm natural structure of Xe-Derma stimulates proliferation and differentiation of human primary keratinocytes and by this way improves wound healing. PMID:22629190

  1. Human keratinocyte growth and differentiation on acellular porcine dermal matrix in relation to wound healing potential.

    PubMed

    Zajicek, Robert; Mandys, Vaclav; Mestak, Ondrej; Sevcik, Jan; Königova, Radana; Matouskova, Eva

    2012-01-01

    A number of implantable biomaterials derived from animal tissues are now used in modern surgery. Xe-Derma is a dry, sterile, acellular porcine dermis. It has a remarkable healing effect on burns and other wounds. Our hypothesis was that the natural biological structure of Xe-Derma plays an important role in keratinocyte proliferation and formation of epidermal architecture in vitro as well as in vivo. The bioactivity of Xe-Derma was studied by a cell culture assay. We analyzed growth and differentiation of human keratinocytes cultured in vitro on Xe-Derma, and we compared the results with formation of neoepidermis in the deep dermal wounds treated with Xe-Derma. Keratinocytes cultured on Xe-Derma submerged in the culture medium achieved confluence in 7-10 days. After lifting the cultures to the air-liquid interface, the keratinocytes were stratified and differentiated within one week, forming an epidermis with basal, spinous, granular, and stratum corneum layers. Immunohistochemical detection of high-molecular weight cytokeratins (HMW CKs), CD29, p63, and involucrin confirmed the similarity of organization and differentiation of the cultured epidermal cells to the normal epidermis. The results suggest that the firm natural structure of Xe-Derma stimulates proliferation and differentiation of human primary keratinocytes and by this way improves wound healing.

  2. The dosimetric impact of implants on the spinal cord dose during stereotactic body radiotherapy.

    PubMed

    Yazici, Gozde; Sari, Sezin Yuce; Yedekci, Fazli Yagiz; Yucekul, Altug; Birgi, Sumerya Duru; Demirkiran, Gokhan; Gultekin, Melis; Hurmuz, Pervin; Yazici, Muharrem; Ozyigit, Gokhan; Cengiz, Mustafa

    2016-05-25

    The effects of spinal implants on dose distribution have been studied for conformal treatment plans. However, the dosimetric impact of spinal implants in stereotactic body radiotherapy (SBRT) treatments has not been studied in spatial orientation. In this study we evaluated the effect of spinal implants placed in sawbone vertebra models implanted as in vivo instrumentations. Four different spinal implant reconstruction techniques were performed using the standard sawbone lumbar vertebrae model; 1. L2-L4 posterior instrumentation without anterior column reconstruction (PI); 2. L2-L4 anterior instrumentation, L3 corpectomy, and anterior column reconstruction with a titanium cage (AIAC); 3. L2-L4 posterior instrumentation, L3 corpectomy, and anterior column reconstruction with a titanium cage (PIAC); 4. L2-L4 anterior instrumentation, L3 corpectomy, and anterior column reconstruction with chest tubes filled with bone cement (AIABc). The target was defined as the spinous process and lamina of the lumbar (L) 3 vertebra. A thermoluminescent dosimeter (TLD, LiF:Mg,Ti) was located on the measurement point anterior to the spinal cord. The prescription dose was 8 Gy and the treatment was administered in a single fraction using a CyberKnife® (Accuray Inc., Sunnyvale, CA, USA). We performed two different treatment plans. In Plan A beam interaction with the rod was not limited. In plan B the rod was considered a structure of avoidance, and interaction between the rod and beam was prevented. TLD measurements were compared with the point dose calculated by the treatment planning system (TPS). In plan A, the difference between TLD measurement and the dose calculated by the TPS was 1.7 %, 2.8 %, and 2.7 % for the sawbone with no implant, PI, and PIAC models, respectively. For the AIAC model the TLD dose was 13.8 % higher than the TPS dose; the difference was 18.6 % for the AIABc model. In plan B for the AIAC and AIABc models, TLD measurement was 2.5 % and 0.9 % higher than the dose calculated by the TPS, respectively. Spinal implants may be present in the treatment field in patients scheduled to undergo SBRT. For the types of implants studied herein anterior rod instrumentation resulted in an increase in the spinal cord dose, whereas use of a titanium cage had a minimal effect on dose distribution. While planning SBRT in patients with spinal reconstructions, avoidance of the rod and preventing interaction between the rod and beam might be the optimal solution for preventing unexpectedly high spinal cord doses.

  3. Management characteristics, lameness, and body injuries of dairy cattle housed in high-performance dairy herds in Wisconsin.

    PubMed

    Cook, N B; Hess, J P; Foy, M R; Bennett, T B; Brotzman, R L

    2016-07-01

    The objective of this study was to benchmark the prevalence of lameness, hock and knee injuries, and neck and back injuries among high-performance, freestall-housed dairy herds in Wisconsin. A random selection of 66 herds with 200 or more cows was derived from herds that clustered with high performance in year 2011 Dairy Herd Improvement records for milk production, udder health, reproduction, and other health parameters. Herds were surveyed to collect information about management, facilities, and well-being. Well-being measures were obtained through direct observation of the high-producing mature cow group, surveying 9,690 cows in total. Total herd size averaged (mean ± standard deviation) 851±717 cows, ranging 203 to 2,966 cows, with an energy-corrected milk production of 40.1±4.4kg/cow per day. Prevalence of clinical lameness (5-point scale, locomotion score ≥3) and severe lameness (locomotion score ≥4) averaged 13.2±7.3 and 2.5±2.7%, respectively. The prevalence of all hock and knee injuries, including hair loss, swelling, and ulceration, was similar at 50.3±28.3 and 53.0±24.0%, respectively. Severe (swelling and ulceration) hock and knee injury prevalence were 12.2±15.3 and 6.2±5.5%, respectively. The prevalence of all neck injuries (including hair loss, swelling and ulceration) was 8.6±16.3%; whereas the prevalence of swollen or abraded necks was low, averaging 2.0±4.1%. Back injuries (proportion of cows with missing or abraded spinous processes, hooks, or pins) followed a similar trend with a low mean prevalence of 3.6±3.4%. Overall, physical well-being characteristics of this selection of high-producing, freestall-housed dairy herds provide evidence that lameness and injury are not inevitable consequences of the confinement housing of large numbers of dairy cattle. In particular, lameness prevalence rivals that of lower-production grazing systems. However, hock and other injury risk remains a concern that can be addressed through a choice in stall surface type. Use of deep, loose bedding yielded significant advantages over a mat or mattress type surface in terms of lameness, hock and knee injury, and proportion of cows with dirty udders (distinct demarcated to confluent plaques of manure). The performance benchmarks achieved by these herds may be used to set standards by which similarly managed herds may be judged using welfare audit tools. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Transforaminal Lumbar Interbody Fusion with Rigid Interspinous Process Fixation: A Learning Curve Analysis of a Surgeon Team's First 74 Cases.

    PubMed

    Doherty, Patrick; Welch, Arthur; Tharpe, Jason; Moore, Camille; Ferry, Chris

    2017-05-30

    Studies have shown that a significant learning curve may be associated with adopting minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) with bilateral pedicle screw fixation (BPSF). Accordingly, several hybrid TLIF techniques have been proposed as surrogates to the accepted BPSF technique, asserting that less/fewer fixation(s) or less disruptive fixation may decrease the learning curve while still maintaining the minimally disruptive benefits. TLIF with interspinous process fixation (ISPF) is one such surrogate procedure. However, despite perceived ease of adaptability given the favorable proximity of the spinous processes, no evidence exists demonstrating whether or not the technique may possess its own inherent learning curve. The purpose of this study was to determine whether an intraoperative learning curve for one- and two-level TLIF + ISPF may exist for a single lead surgeon. Seventy-four consecutive patients who received one- or two-Level TLIF with rigid ISPF by a single lead surgeon were retrospectively reviewed. It was the first TLIF + ISPF case series for the lead surgeon. Intraoperative blood loss (EBL), hospitalization length-of-stay (LOS), fluoroscopy time, and postoperative complications were collected. EBL, LOS, and fluoroscopy time were modeled as a function of case number using multiple linear regression methods. A change point was included in each model to allow the trajectory of the outcomes to change during the duration of the case series. These change points were determined using profile likelihood methods. Models were fit using the maximum likelihood estimates for the change points. Age, sex, body mass index (BMI), and the number of treated levels were included as covariates. EBL, LOS, and fluoroscopy time did not significantly differ by age, sex, or BMI (p ≥ 0.12). Only EBL differed significantly by the number of levels (p = 0.026). The case number was not a significant predictor of EBL, LOS, or fluoroscopy time (p ≥ 0.21). At the time of data collection (mean time from surgery: 13.3 months), six patients had undergone revision due to interbody migration. No ISPF device complications were observed. Study outcomes support the ideal that TLIF + ISPF can be a readily adopted procedure without a significant intraoperative learning curve. However, the authors emphasize that further assessment of long-term healing outcomes is essential in fully characterizing both the efficacy and the indication learning curve for the TLIF + ISPF technique.

  5. Turning the backbone into an ankylosed concrete-like structure: Case report.

    PubMed

    Kaissi, Ali Al; Chehida, Farid Ben; Grill, Franz; Ganger, Rudolf; Kircher, Susanne Gerit

    2018-04-01

    Progressive restriction of the spinal bio-mechanics is not-uncommon deformity encountered in spine clinics. Congenital spinal fusion as seen in Klippel-Feil-anomaly, progressive non-infectious anterior vertebral fusion, and progressive spinal hyperostosis secondary to ossification of the anterior longitudinal spinal ligament are well delineated and recognized. A 24-year-old girl has history of osteoporosis since her early childhood, associated with multiple axial and appendicular fractures and scoliosis. Recently she presented with episodes of severe back pain, spinal rigidity/stiffness with total loss of spine biomechanics. She was provisionally diagnosed as having osteogenesis imperfecta and was investigated for COL1A1/A2 mutations which have been proven to be negative. Autosomal recessive type of osteogenesis imperfecta was proposed as well, no mutations have been encountered. A homozygous for CTSA gene mutation, the gene associated with Galactosialidosis was identified via whole exome sequencing (Next-Generation Sequencing projects) has been identified. Early in her life she had a history of frequent fractures of the long bones since she was 4 years which was followed by vertebral fractures at the age of 12 years. She manifested lower serum 25OH-D levels and were associated with lower LS-aBMD Z-scores with higher urinary bone turnover indexes (urinary NTX/Cr). Lysosomal storage diseases (LSD) have a strong correlation with the development of osteoporosis. LSD causes skeletal abnormalities results from a lack of skeletal remodeling and ossification abnormalities owing to abnormal deposition of GAGs (impaired degradation of glycosaminoglycans ) in bone and cartilage. 3D reconstruction CT scan of the spine showed diffuse hyperostosis of almost the entire spine (begins at the level of T4- extending downwards to involve the whole thoraco-lumbar and upper part of the sacrum) with total diffuse fusion of the pedicles, the transverse and articular processes, the laminae and the spinous processes. This is the first clinical report of adult patient with a history of osteoporosis and fractures with the late diagnosis of Galactosialidosis. Osteogenesis imperfecta (autosomal dominant and recessive) were the first given diagnoses which proven negative. The pathophysiology of the spine ankylosis in our current patient and its correlation with LSD, antiresorptive medications, vitamin D3 and supplemental calcium is not fully understood. Therefore, further studies are needed to elucidate this sort of correlation.

  6. A description of the lumbar interfascial triangle and its relation with the lateral raphe: anatomical constituents of load transfer through the lateral margin of the thoracolumbar fascia

    PubMed Central

    Schuenke, M D; Vleeming, A; Van Hoof, T; Willard, F H

    2012-01-01

    Movement and stability of the lumbosacral region is contingent on the balance of forces distributed through the myofascial planes associated with the thoracolumbar fascia (TLF). This structure is located at the common intersection of several extremity muscles (e.g. latissimus dorsi and gluteus maximus), as well as hypaxial (e.g. ventral trunk muscles) and epaxial (paraspinal) muscles. The mechanical properties of the fascial constituents establish the parameters guiding the dynamic interaction of muscle groups that stabilize the lumbosacral spine. Understanding the construction of this complex myofascial junction is fundamental to biomechanical analysis and implementation of effective rehabilitation in individuals with low back and pelvic girdle pain. Therefore, the main objectives of this study were to describe the anatomy of the lateral margin of the TLF, and specifically the interface between the fascial sheath surrounding the paraspinal muscles and the aponeurosis of the transversus abdominis (TA) and internal oblique (IO) muscles. The lateral margin of the TLF was exposed via serial reduction dissections from anterior and posterior approaches. Axial sections (cadaveric and magnetic resonance imaging) were examined to characterize the region between the TA and IO aponeurosis and the paraspinal muscles. It is confirmed that the paraspinal muscles are enveloped by a continuous paraspinal retinacular sheath (PRS), formed by the deep lamina of the posterior layer of the TLF. The PRS extends from the spinous process to transverse process, and is distinct from both the superficial lamina of the posterior layer and middle layer of the TLF. As the aponeurosis approaches the lateral border of the PRS, it appears to separate into two distinct laminae, which join the anterior and posterior walls of the PRS. This configuration creates a previously undescribed fat-filled lumbar interfascial triangle situated along the lateral border of the paraspinal muscles from the 12th rib to the iliac crest. This triangle results in the unification of different fascial sheaths along the lateral border of the TLF, creating a ridged-union of dense connective tissue that has been termed the lateral raphe (Spine, 9,1984, 163). This triangle may function in the distribution of laterally mediated tension to balance different viscoelastic moduli, along either the middle or posterior layers of the TLF. PMID:22582887

  7. DISCUSSION ON SPINAL INJURIES

    PubMed Central

    1928-01-01

    (1).—Varieties of spinal injuries, the three groups of common usage: fractures, dislocations, fracture-dislocations. Shall not refer in detail to fractures of the spinous or transverse processes. (2) Mechanics of injury to vertebræ. Two variables: (1) the nature of the bones; (2) the qualities of the force. Spinal injury usually caused by indirect violence. (3) The different results of injuries applied to the head; may break skull, failing that, the neck. Atlas fracture. Difference in qualities of the force causing atlas fracture and low cervical dislocation. (4) The compound nature of the vertebral body. The two columns, anterior, spongy; posterior, compact. The nature of wedge-compression of the vertebral body. Variations in the shape of the wedge. Reasons. Occur at all levels, including cervical spine. (5) Frequency of injury at different levels of vertebral column. “Localization” of injury. The two places of the graph of injury. The cervical at C. 5. Reason. The thoracic-lumbar peak at T. 12, L. 1 industrial. Is there a third peak at C. 2? (6) The effects of violent flexion of the spine: cervical flexion causes luxation at C. 5 or so. Extension causes fracture of odontoid. Violent flexion and extension therefore cause injury at very different levels. Thoracic region, why is there no “peak” of injury at T.6, 7? Lumbar region. (7) Displacement of fragments. Continuation of violence after the essential injury has been effected. Kümmell's disease, no inflammatory process involved. (8) Injury to the intervertebral discs, essential for displacement. Imperfect rupture a cause for difficulty in reducing luxations. The worst cases those in which it is most easily done, but most of these have cord damage. (9) Spinal injury from minimal violence. Examples of trivial cases, diving, brushing hair and so forth. Vertebral displacement in disease a much more serious thing. (10) Curious stability of many cervical luxations. Reasons. Locking of the inferior zygaphophyses. (11) Injury to nervous elements left principally to other speakers. Cord compression very rare. Immediate and irremediable damage. Root injuries. Falling mortality of modern statistics due to better diagnosis. (12) Primary operation for fractures of spine relegated to oblivion. Rarity of indications for open operation. Reduction the best treatment. ImagesFig. 5Fig. 6 PMID:19986314

  8. Interleukin 22 early affects keratinocyte differentiation, but not proliferation, in a three-dimensional model of normal human skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Donetti, Elena, E-mail: elena.donetti@unimi.it; Cornaghi, Laura; Arnaboldi, Francesca

    Interleukin (IL)-22 is a pro-inflammatory cytokine driving the progression of the psoriatic lesion with other cytokines, as Tumor Necrosis Factor (TNF)-alpha and IL-17. Our study was aimed at evaluating the early effect of IL-22 alone or in combination with TNF-alpha and IL-17 by immunofluorescence on i) keratinocyte (KC) proliferation, ii) terminal differentiation biomarkers as keratin (K) 10 and 17 expression, iii) intercellular junctions. Transmission electron microscopy (TEM) analysis was performed. A model of human skin culture reproducing a psoriatic microenvironment was used. Plastic surgery explants were obtained from healthy young women (n=7) after informed consent. Fragments were divided before addingmore » IL-22 or a combination of the three cytokines, and harvested 24 (T24), 48 (T48), and 72 (T72) h later. From T24, in IL-22 samples we detected a progressive decrease in K10 immunostaining in the spinous layer paralleled by K17 induction. By TEM, after IL-22 incubation, keratin aggregates were evident in the perinuclear area. Occludin immunostaining was not homogeneously distributed. Conversely, KC proliferation was not inhibited by IL-22 alone, but only by the combination of cytokines. Our results suggest that IL-22 affects keratinocyte terminal differentiation, whereas, in order to induce a proliferation impairment, a more complex psoriatic-like microenvironment is needed.« less

  9. Spinal Motion and Muscle Activity during Active Trunk Movements – Comparing Sheep and Humans Adopting Upright and Quadrupedal Postures

    PubMed Central

    Valentin, Stephanie; Licka, Theresia F.

    2016-01-01

    Sheep are used as models for the human spine, yet comparative in vivo data necessary for validation is limited. The purpose of this study was therefore to compare spinal motion and trunk muscle activity during active trunk movements in sheep and humans. Three-dimensional kinematic data as well as surface electromyography (sEMG) of spinal flexion and extension was compared in twenty-four humans in upright (UR) and 4-point kneeling (KN) postures and in 17 Austrian mountain sheep. Kinematic markers were attached over the sacrum, posterior iliac spines, and spinous and transverse processes of T5, T8, T11, L2 and L5 in humans and over the sacrum, tuber sacrale, T5, T8, T12, L3 and L7 in sheep. The activity of erector spinae (ES), rectus abdominis (RA), obliquus externus (OE), and obliquus internus (OI) were collected. Maximum sEMG (MOE) was identified for each muscle and trial, and reported as a percentage (MOE%) of the overall maximally observed sEMG from all trials. Spinal range of motion was significantly smaller in sheep compared to humans (UR / KN) during flexion (sheep: 6–11°; humans 12–34°) and extension (sheep: 4°; humans: 11–17°). During extension, MOE% of ES was greater in sheep (median: 77.37%) than UR humans (24.89%), and MOE% of OE and OI was greater in sheep (OE 76.20%; OI 67.31%) than KN humans (OE 21.45%; OI 19.34%), while MOE% of RA was lower in sheep (21.71%) than UR humans (82.69%). During flexion, MOE% of RA was greater in sheep (83.09%) than humans (KN 47.42%; UR 41.38%), and MOE% of ES in sheep (45.73%) was greater than KN humans (14.45%), but smaller than UR humans (72.36%). The differences in human and sheep spinal motion and muscle activity suggest that caution is warranted when ovine data are used to infer human spine biomechanics. PMID:26741136

  10. Transcutaneous spinal direct current stimulation of the lumbar and sacral spinal cord: a modelling study

    NASA Astrophysics Data System (ADS)

    Fernandes, Sofia R.; Salvador, Ricardo; Wenger, Cornelia; de Carvalho, Mamede; Miranda, Pedro C.

    2018-06-01

    Objective. Our aim was to perform a computational study of the electric field (E-field) generated by transcutaneous spinal direct current stimulation (tsDCS) applied over the thoracic, lumbar and sacral spinal cord, in order to assess possible neuromodulatory effects on spinal cord circuitry related with lower limb functions. Approach. A realistic volume conductor model of the human body consisting of 14 tissues was obtained from available databases. Rubber pad electrodes with a metallic connector and a conductive gel layer were modelled. The finite element (FE) method was used to calculate the E-field when a current of 2.5 mA was passed between two electrodes. The main characteristics of the E-field distributions in the spinal grey matter (spinal-GM) and spinal white matter (spinal-WM) were compared for seven montages, with the anode placed either over T10, T8 or L2 spinous processes (s.p.), and the cathode placed over right deltoid (rD), umbilicus (U) and right iliac crest (rIC) areas or T8 s.p. Anisotropic conductivity of spinal-WM and of a group of dorsal muscles near the vertebral column was considered. Main results. The average E-field magnitude was predicted to be above 0.15 V m-1 in spinal cord regions located between the electrodes. L2-T8 and T8-rIC montages resulted in the highest E-field magnitudes in lumbar and sacral spinal segments (>0.30 V m-1). E-field longitudinal component is 3 to 6 times higher than the ventral-dorsal and right-left components in both the spinal-GM and WM. Anatomical features such as CSF narrowing due to vertebrae bony edges or disks intrusions in the spinal canal correlate with local maxima positions. Significance. Computational modelling studies can provide detailed information regarding the electric field in the spinal cord during tsDCS. They are important to guide the design of clinical tsDCS protocols that optimize stimulation of application-specific spinal targets.

  11. Efficacy of the use of two simultaneously TENS devices for fibromyalgia pain.

    PubMed

    Lauretti, Gabriela Rocha; Chubaci, Eliana Fazuoli; Mattos, Anita Leocadia

    2013-08-01

    Fibromyalgia is characterized by a range of symptoms that include muscle pain, fatigue and sleep disorders. Transcutaneous electrical nerve stimulation (TENS) is an established method for pain relief. The purpose of the study was to evaluate the effectiveness and safety of the use of two simultaneously new TENS devices for fibromyalgia pain. After Ethics approval and informed consent, 39 patients were prospectively divided into three groups to evaluate TENS device, applied simultaneously in each patient: (1) at the lower back (perpendicular to the vertebrae canal, at the level of the 5th lumbar vertebrae) and (2) centrally above and below the space between the C7 and T1 spinous processes. The devices were applied for 20 min at 12-h interval during 7 consecutive days. For the placebo group (PG), the devices did not transmitted electrical stimulus. The single-TENS group (STG) (n = 13) had one active and one placebo TENS. The DTG applied both active TENS devices at the low back and cervical areas. Diclofenac was used as rescue analgesic. The efficacy measures were pain relief, reduction in use of daily analgesic tablets, quality of sleep and fatigue. The evaluation within groups revealed that patients from DPG refereed no pain relief when compared to their previous VAS pain score (8 cm, p > 0.05), while patients from the STG refereed improvement of 2.5 cm in the pain VAS (previous 8.5 cm compared to 6 cm after treatment) (p < 0.05), and the DPG refereed daily maintained reduction of 4 cm in the VAS pain (previous 8.5-4.3 cm) (p < 0.02). Concurrent daily consumption of analgesic tablets was reduced in both STG (p < 0.05) and DTG (p < 0.02). Comparison among groups revealed that analgesia, as well as quality of sleep and disposition, was DTG > STG > PG (p < 0.05). Participants subjectively found the active device useful. While the application of a single active TENS improved pain relief in fibromyalgia pain, pain and fatigue were further improved when two active devices were simultaneously applied at the low back and cervical area, with no side effects.

  12. Functional Magnetic Stimulation of Inspiratory and Expiratory Muscles in Subjects With Tetraplegia.

    PubMed

    Zhang, Xiaoming; Plow, Ela; Ranganthan, Vinoth; Huang, Honglian; Schmitt, Melissa; Nemunaitis, Gregory; Kelly, Clay; Frost, Frederick; Lin, Vernon

    2016-07-01

    Respiratory complications are major causes of morbidity and mortality in persons with a spinal cord injury, partly because of respiratory muscle paralysis. Earlier investigation has demonstrated that functional magnetic stimulation (FMS) can be used as a noninvasive technology for activating expiratory muscles, thus producing useful expiratory functions (simulated cough) in subjects with spinal cord injury. To evaluate the effectiveness of FMS for conditioning inspiratory and expiratory muscles in persons with tetraplegia. A prospective before and after trial. FMS Laboratory, Louis Stokes Cleveland VA Medical Center, Cleveland, OH. Six persons with tetraplegia. Each subject participated in a 6-week FMS protocol for conditioning the inspiratory and expiratory muscles. A magnetic stimulator was used with the center of a magnetic coil placed at the C7-T1 and T9-T10 spinous processes, respectively. Pulmonary function tests were performed before, during, and after the protocol. Respiratory variables included maximal inspiratory pressure (MIP), inspiratory reserve volume (IRV), peak inspiratory flow (PIF), maximal expiratory pressure (MEP), expiratory reserve volume (ERV), and peak expiratory flow (PEF). After 6 weeks of conditioning, the main outcome measurements (mean ± standard error) were as follows: MIP, 89.6 ± 7.3 cm H2O; IRV, 1.90 ± 0.34 L; PIF, 302.4 ± 36.3 L/min; MEP, 67.4 ± 11.1 cm H2O; ERV, 0.40 ± 0.06 L; and PEF, 372.4 ± 31.9 L/min. These values corresponded to 117%, 107%, 136%, 109%, 130%, and 124% of pre-FMS conditioning values, respectively. Significant improvements were observed in MIP (P = .022), PIF (P = .0001), and PEF (P = .0006), respectively. When FMS was discontinued for 4 weeks, these values showed decreases from their values at the end of the conditioning protocol, which suggests that continual FMS may be necessary to maintain improved respiratory functions. FMS conditioning of the inspiratory and expiratory muscles improved voluntary inspiratory and expiratory functions. FMS may be a noninvasive technology for respiratory muscle training in persons with tetraplegia. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. [A feasibility research of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using hybrid internal fixation for recurrent lumbar disc herniation].

    PubMed

    Mao, Ke-ya; Wang, Yan; Xiao, Song-hua; Zhang, Yong-gang; Liu, Bao-wei; Wang, Zheng; Zhang, Xi-Feng; Cui, Geng; Zhang, Xue-song; Li, Peng; Mao, Ke-zheng

    2013-08-01

    To investigate the feasibility of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using hybrid internal fixation of pedicle screws and a translaminar facet screw for recurrent lumbar disc herniation. From January 2010 to December 2011, 16 recurrent lumbar disc herniation patients, 10 male and 6 female patients with an average age of 45 years (35-68 years) were treated with unilateral incision MIS-TLIF through working channel. After decompression, interbody fusion and fixation using unilateral pedicle screws, a translaminar facet screw was inserted from the same incision through spinous process and laminar to the other side facet joint. The results of perioperative parameters, radiographic images and clinical outcomes were assessed. The repeated measure analysis of variance was applied in the scores of visual analogue scale (VAS) and Oswestry disablity index (ODI). All patients MIS-TLIF were accomplished under working channel including decompression, interbody fusion and hybrid fixation without any neural complication. The average operative time was (148 ± 75) minutes, the average operative blood loss was (186 ± 226) ml, the average postoperative ambulation time was (32 ± 15) hours, and the average hospitalization time was (6 ± 4) days. The average length of incision was (29 ± 4) mm, and the average length of translaminar facets screw was (52 ± 6) mm. The mean follow-up was 16.5 months with a range of 12-24 months. The postoperative X-ray and CT images showed good position of the hybrid internal fixation, and all facets screws penetrate through facets joint. The significant improvement could be found in back pain VAS, leg pain VAS and ODI scores between preoperative 1 day and postoperative follow-up at all time-points (back pain VAS:F = 52.845, P = 0.000;leg pain VAS:F = 113.480, P = 0.000;ODI:F = 36.665, P = 0.000). Recurrent lumbar disc herniation could be treated with MIS-TLIF using hybrid fixation through unilateral incision, and the advantage including less invasion and quickly recovery.

  14. Limitation of activities of daily living accompanying reduced neck mobility after laminoplasty preserving or reattaching the semispinalis cervicis into axis.

    PubMed

    Takeuchi, Kazunari; Yokoyama, Toru; Ono, Atsushi; Numasawa, Takuya; Wada, Kanichiro; Itabashi, Taito; Toh, Satoshi

    2008-03-01

    Although difficulties with neck mobility often interfere with patients' activities of daily living (ADL) after cervical laminoplasty, there was no detailed study on the relation between the limitations of ADL accompanying postoperative reduced neck mobility and the cervical posterior approach. The aim of this study was to compare retrospectively the frequency of limitations of ADL accompanying neck mobility after laminoplasty preserving the semispinalis cervicis inserted into the C2 spinous process with that after laminoplasty reattaching the muscle to C2. Forty-nine patients after C4-C7 laminoplasty with C3 laminectomy preserving the semispinalis cervicis inserted into C2 (Group A) and 24 patients after C3-C7 laminoplasty reattaching the muscle (Group B) were evaluated. The frequency of postoperative limitations of ADL accompanying each of three neck movements of extension, flexion and rotation were investigated. The postoperative O-C7 angles at extension and flexion was measured on lateral extension and flexion radiographs of the cervical spine, respectively. The postoperative cervical range of motion in rotation was measured in the cranial view using a digital camera. Frequency of limitations of ADL accompanying extension was lower (P = 0.037) in Group A (2%) than in Group B (17%). Frequency of limitations of ADL accompanying flexion was similar in Group A (8%) and Group B (4%). Frequency of limitations of ADL accompanying rotation was lower (P = 0.031) in Group A (12%) than in Group B (33%). Average O-C7 angle at extension was significantly larger (P = 0.002) in Group A (147 degrees ) than in Group B (136 degrees ). Average O-C7 angle at flexion was similar in Group A (93 degrees ) and Group B (91 degrees ). Average range of motion in rotation was significantly larger (P = 0.004) in Group A (110 degrees ) than in Group B (91 degrees ). This retrospective study suggested that the frequency of limitations of ADL accompanying neck extension or rotation was lower after laminoplasty preserving the semispinalis cervicis inserted into C2 than after laminoplasty reattaching the muscle.

  15. Spinal Motion and Muscle Activity during Active Trunk Movements - Comparing Sheep and Humans Adopting Upright and Quadrupedal Postures.

    PubMed

    Valentin, Stephanie; Licka, Theresia F

    2016-01-01

    Sheep are used as models for the human spine, yet comparative in vivo data necessary for validation is limited. The purpose of this study was therefore to compare spinal motion and trunk muscle activity during active trunk movements in sheep and humans. Three-dimensional kinematic data as well as surface electromyography (sEMG) of spinal flexion and extension was compared in twenty-four humans in upright (UR) and 4-point kneeling (KN) postures and in 17 Austrian mountain sheep. Kinematic markers were attached over the sacrum, posterior iliac spines, and spinous and transverse processes of T5, T8, T11, L2 and L5 in humans and over the sacrum, tuber sacrale, T5, T8, T12, L3 and L7 in sheep. The activity of erector spinae (ES), rectus abdominis (RA), obliquus externus (OE), and obliquus internus (OI) were collected. Maximum sEMG (MOE) was identified for each muscle and trial, and reported as a percentage (MOE%) of the overall maximally observed sEMG from all trials. Spinal range of motion was significantly smaller in sheep compared to humans (UR / KN) during flexion (sheep: 6-11°; humans 12-34°) and extension (sheep: 4°; humans: 11-17°). During extension, MOE% of ES was greater in sheep (median: 77.37%) than UR humans (24.89%), and MOE% of OE and OI was greater in sheep (OE 76.20%; OI 67.31%) than KN humans (OE 21.45%; OI 19.34%), while MOE% of RA was lower in sheep (21.71%) than UR humans (82.69%). During flexion, MOE% of RA was greater in sheep (83.09%) than humans (KN 47.42%; UR 41.38%), and MOE% of ES in sheep (45.73%) was greater than KN humans (14.45%), but smaller than UR humans (72.36%). The differences in human and sheep spinal motion and muscle activity suggest that caution is warranted when ovine data are used to infer human spine biomechanics.

  16. TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bredfeldt, JS; Liu, L; Feng, M

    2016-06-15

    Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone,more » or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.« less

  17. The cat vertebral column: stance configuration and range of motion

    NASA Technical Reports Server (NTRS)

    Macpherson, J. M.; Ye, Y.; Peterson, B. W. (Principal Investigator)

    1998-01-01

    This study examined the configuration of the vertebral column of the cat during independent stance and in various flexed positions. The range of motion in the sagittal plane is similar across most thoracic and lumbar joints, with the exception of a lesser range at the transition region from thoracic-type to lumbar-type vertebrae. The upper thoracic column exhibits most of its range in dorsiflexion and the lower thoracic and lumbar in ventroflexion. Lateral flexion is limited to less than 5 degrees at all segments. The range in torsion is almost 180 degrees and occurs primarily in the midthoracic region, T4-T11. Contrary to the depiction in most atlases, the standing cat exhibits several curvatures, including a mild dorsiflexion in the lower lumbar segments, a marked ventroflexion in the lower thoracic and upper lumbar segments, and a profound dorsiflexion in the upper thoracic (above T9) and cervical segments. The curvatures are not significantly changed by altering stance distance but are affected by head posture. During stance, the top of the scapula lies well above the spines of the thoracic vertebrae, and the glenohumeral joint is just below the bodies of vertebrae T3-T5. Using a simple static model of the vertebral column in the sagittal plane, it was estimated that the bending moment due to gravity is bimodal with a dorsiflexion moment in the lower thoracic and lumbar region and a ventroflexion moment in the upper thoracic and cervical region. Given the bending moments and the position of the scapula during stance, it is proposed that two groups of scapular muscles provide the major antigravity support for the head and anterior trunk. Levator scapulae and serratus ventralis form the lateral group, inserting on the lateral processes of cervical vertebrae and on the ribs. The major and minor rhomboids form the medial group, inserting on the spinous tips of vertebrae from C4 to T4. It is also proposed that the hypaxial muscles, psoas major, minor, and quadratus lumborum could support the lumbar trunk during stance.

  18. Effects of thrust amplitude and duration of high velocity low amplitude spinal manipulation on lumbar muscle spindle responses to vertebral position and movement

    PubMed Central

    Cao, Dong-Yuan; Reed, William R.; Long, Cynthia R.; Kawchuk, Gregory N.; Pickar, Joel G.

    2013-01-01

    OBJECTIVE Mechanical characteristics of high velocity low amplitude spinal manipulations (HVLA-SM) can be variable. Sustained changes in peripheral neuronal signaling due to altered load transmission to a sensory receptor’s local mechanical environment are often considered a mechanism contributing to the therapeutic effects of spinal manipulation. The purpose of this study was to determine whether an HVLA-SM’s thrust amplitude or duration altered neural responsiveness of lumbar muscle spindles to either vertebral movement or position. METHODS Anesthetized cats (n=112) received L6 HVLA-SMs delivered to the spinous process. Cats were divided into 6 cohorts depending upon the peak thrust force (25%, 55%, 85% body weight) or thrust displacement (1, 2, 3mm) they received. Cats in each cohort received 8 thrust durations (0–250ms). Afferent discharge from 112 spindles was recorded in response to ramp and hold vertebral movement before and after the manipulation. Changes in mean instantaneous frequency (MIF) during the baseline period preceding the ramps (ΔMIFresting), during ramp movements (ΔMIFmovement), and with the vertebra held in the new position (ΔMIFposition) were compared. RESULTS Thrust duration had a small but statistically significant effect on ΔMIFresting at all six thrust amplitudes compared to control (0ms thrust duration). The lowest amplitude thrust displacement (1mm) increased ΔMIFresting at all thrust durations. For all the other thrust displacements and forces, the direction of change in ΔMIFresting was not consistent and the pattern of change was not systematically related to thrust duration. Regardless of thrust force, displacement, or duration, ΔMIFmovement and ΔMIFposition were not significantly different from control. Conclusion Relatively low amplitude thrust displacements applied during an HVLA-SM produced sustained increases in the resting discharge of paraspinal muscle spindles regardless of the duration over which the thrust was applied. However, regardless of the HVLA-SM’s thrust amplitude or duration, the responsiveness of paraspinal muscle spindles to vertebral movement and to a new vertebral position was not affected. PMID:23499141

  19. Aporocotyle michaudi n. sp. (Digenea: Aporocotylidae) from the emerald rock cod, Trematomus bernacchii (Teleostei: Perciformes) in Antarctica.

    PubMed

    Santoro, Mario; Cipriani, Paolo; Pankov, Plamen; Lawton, Scott P

    2015-10-01

    Aporocotyle michaudi n. sp. is described from the gill blood vessels of the emerald rock cod Trematomus bernacchii in the Ross Sea, Antarctica. It is distinguished from all other species of Aporocotyle by its body tegument showing single conical spines, spinous buccal capsule, and genital atrium positioned medially; all congeners described to date are characterized by clusters of tegumental spines, unspined buccal capsule and genital atrium located in the lateral part of the body. Aporocotyle michaudi n. sp. clearly differs from A. notothenia (the only other species of Aporocotyle found in a perciform fish) in its shape and arrangement of tegumental spines, buccal capsule features, location of genital atrium, body size, ratio of esophagus/body length, anterior caeca/posterior caeca ratio, number of testes, cirrus sac and ovary size and shape, and host. The new species is easily distinguished from A. argentinensis (the species that most closely resembles A. michaudi) by the shape and arrangement of tegumental spines, buccal capsule features, genital atrium location, left anterior caecum longer than right, esophagus/body length ratio, number of testes, cirrus sac size and shape, host and molecular analyses. Phylogenetic analyses of partial 28S rDNA genetic data showed that sequences representing the new species form a distinct clade with all other sequences for species of Aporocotyle and appear basal within the genus. Aporocotyle michaudi n. sp. represents the only species of genus described in Antarctica. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Dorsal motor nucleus of the vagus neurons: a multivariate taxonomy.

    PubMed

    Jarvinen, M K; Powley, T L

    1999-01-18

    The dorsal motor nucleus of the vagus (DMNX) contains neurons with different projections and discrete functions, but little success has been achieved in distinguishing the cells cytoarchitectonically. The present experiment employed multivariate analytical techniques to evaluate DMNX neuronal morphology. Male Sprague-Dawley rats (n = 77) were perfused, and the brainstems were stained en bloc with a Golgi-Cox protocol. DMNX neurons in each of three planes (coronal, sagittal, and horizontal; total sample = 607) were digitized. Three-dimensional features quantified included dendritic length, number of segments, spine density, number of primary dendrites, dendritic orientation, and soma form factor. Cluster analyses of six independent samples of 100+ neurons and of three composite replicate pools of 200+ neurons consistently identified similar sets of four distinct neuronal profiles. One profile (spinous, limited dendrites, small somata) appears to correspond to the interneuron population of the DMNX. In contrast, the other three distinctive profiles (e.g., one is multipolar, with large dendritic fields and large somata) are different types of preganglionic neurons. Each of the four types of neurons is found throughout the DMNX, suggesting that the individual columnar subnuclei and other postulated vagal motorneuron pools are composed of all types of neurons. Within individual motor pools, ensembles of the different neuronal types must cooperatively organize different functions and project to different effectors within a target organ. By extension, specializations of the preganglionic motor pools are more likely to result from their afferent inputs, peripheral target tissues, neurochemistry, or physiological features rather than from any unique morphological profiles.

  1. [Three-dimensional gait analysis of patients with osteonecrosis of femoral head before and after treatments with vascularized greater trochanter bone flap].

    PubMed

    Cui, Daping; Zhao, Dewei

    2011-03-01

    To provide the objective basis for the evaluation of the operative results of vascularized greater trochanter bone flap in treating osteonecrosis of the femoral head (ONFH) by three-dimensional gait analysis. Between March 2006 and March 2007, 35 patients with ONFH were treated with vascularized greater trochanter bone flap, and gait analysis was made by using three-dimensional gait analysis system before operation and at 1, 2 years after operation. There were 23 males and 12 females, aged 21-52 years (mean, 35.2 years), including 8 cases of steroid-induced, 7 cases of traumatic, 6 cases of alcoholic, and 14 cases of idiopathic ONFH. The left side was involved in 15 cases, and right side in 20 cases. According to Association Research Circulation Osseous (ARCO) classification, all patients were diagnosed as having femoral-head necrosis at stage III. Preoperative Harris hip functional score (HHS) was 56.2 +/- 5.6. The disease duration was 1.5-18.6 years (mean, 5.2 years). All incisions healed at stage I without early postoperative complications of deep vein thrombosis and infections of incision. Thirty-five patients were followed up 2-3 years with an average of 2.5 years. At 2 years after operation, the HHS score was 85.8 +/- 4.1, showing significant difference when compared with the preoperative score (t = 23.200, P = 0.000). Before operation, patients showed a hip muscles gait, short gait, reduce pain gait, and the pathological gaits significantly improved at 1 year after operation. At 1 year and 2 years after operation, step frequency, pace, step length and hip flexion, hip extension, knee flexion, ankle flexion were significantly improved (P < 0.01). Acceleration-time curves showed that negative wave and spinous wave at acceleration-stance phase of front feet and hind feet in affected limb were obviously reduced at 1 year and 2 years after operation. Postoperative petronas wave appeared at swing phase; the preoperative situation was three normal phase waves. These results suggest that three-dimensional gait analysis before and after vascularized greater trochanter for ONFH can evaluate precisely hip vitodynamics variation.

  2. Reduced Synapse and Axon Numbers in the Prefrontal Cortex of Rats Subjected to a Chronic Stress Model for Depression

    PubMed Central

    Csabai, Dávid; Wiborg, Ove; Czéh, Boldizsár

    2018-01-01

    Stressful experiences can induce structural changes in neurons of the limbic system. These cellular changes contribute to the development of stress-induced psychopathologies like depressive disorders. In the prefrontal cortex of chronically stressed animals, reduced dendritic length and spine loss have been reported. This loss of dendritic material should consequently result in synapse loss as well, because of the reduced dendritic surface. But so far, no one studied synapse numbers in the prefrontal cortex of chronically stressed animals. Here, we examined synaptic contacts in rats subjected to an animal model for depression, where animals are exposed to a chronic stress protocol. Our hypothesis was that long term stress should reduce the number of axo-spinous synapses in the medial prefrontal cortex. Adult male rats were exposed to daily stress for 9 weeks and afterward we did a post mortem quantitative electron microscopic analysis to quantify the number and morphology of synapses in the infralimbic cortex. We analyzed asymmetric (Type I) and symmetric (Type II) synapses in all cortical layers in control and stressed rats. We also quantified axon numbers and measured the volume of the infralimbic cortex. In our systematic unbiased analysis, we examined 21,000 axon terminals in total. We found the following numbers in the infralimbic cortex of control rats: 1.15 × 109 asymmetric synapses, 1.06 × 108 symmetric synapses and 1.00 × 108 myelinated axons. The density of asymmetric synapses was 5.5/μm3 and the density of symmetric synapses was 0.5/μm3. Average synapse membrane length was 207 nm and the average axon terminal membrane length was 489 nm. Stress reduced the number of synapses and myelinated axons in the deeper cortical layers, while synapse membrane lengths were increased. These stress-induced ultrastructural changes indicate that neurons of the infralimbic cortex have reduced cortical network connectivity. Such reduced network connectivity is likely to form the anatomical basis for the impaired functioning of this brain area. Indeed, impaired functioning of the prefrontal cortex, such as cognitive deficits are common in stressed individuals as well as in depressed patients. PMID:29440995

  3. Hypolipidemic Activity of Chloroform Extract of Mimosa pudica Leaves

    PubMed Central

    Rajendran, Rekha; Krishnakumar, Ekambaram

    2010-01-01

    Mimosa pudica Lin., known as chue Mue, is a stout straggling prostrate shrubby plant, with spinous stipules and globose pinkish flower heads, and grows as weed in almost all parts of the country. It is traditionally used for its various properties and hence in the present study, chloroform extract of Mimosa pudica leaves has been screened for its hypolipidemic activity. Hypolipidemic activity is screened by inducing hyperlipidemia with the help of atherogenic diet in wistar albino rats and serum levels of various biochemical parameters such as total cholesterol, triglycerides, LDL, VLDL and HDL cholesterol were determined. Atherogenic index shows the measure of the athero-genic potential of the drugs. Chloroform extract showed significant (p < 0.05) hypolipidemic effect by lowering the serum levels of biochemical parameters such as significant reduction in the level of serum cholesterol, triglyceride, LDL, VLDL and increase in HDL level which was similar to the standard drug Atorvastatin. Chloroform extract exhibited significant atherogenic index and percentage protection against hyperlipidemia. These biochemical observations were in turn confirmed by histopathological examinations of aorta, liver and kidney sections and are comparable with the standard hypolipidemic drug Atorvastatin. Preliminary phytochemical analysis revealed the presence of phytoconstituents such as steroids, flavonoids, glycosides, alkaloids, phenolic compounds which is further confirmed by the thin layer chromatography, High Performance Thin Layer Chromatography (HPTLC). The overall experimental results suggests that the biologically active phytoconstituents such as flavonoids, glycosides alkaloids present in the chloroform extract of Mimosa pudica, may be responsible for the significant hypolipidemic activity and the results justify the use of Mimosa pudica as a significant hypolipidemic agent. PMID:23408779

  4. Coenzyme A contained in mothers' milk is associated with the potential to induce atopic dermatitis.

    PubMed

    Higashi, Takehiro; Shimojo, Naoki; Suzuki, Shuichi; Nakaya, Mayuko; Takagi, Rie; Hashimoto, Kumiko; Nakagome, Kazuyuki; Nakamura, Koichiro; Kohno, Yoichi; Matsushita, Sho

    2011-12-01

    T(h)2 adjuvant activity can be qualitatively and quantitatively evaluated using a mixed lymphocyte reaction and by changes in the intracellular cyclic adenosine 3',5'-monophosphate concentration, using human dendritic cells in vitro. The current study shows that mothers, whose children (n = 55) developed atopic dermatitis (AD) within 6 months after birth, often demonstrate a higher T(h)2 adjuvant activity in their milk, in comparison to those whose children did not develop such symptoms. Such an activity was recovered in a liquid phase of mothers' milk and was eluted as a single fraction by reversed-phase HPLC. Further analysis of this fraction by mass spectrometry showed that signals originating from a factor with a molecular weight of 767.53 are observed, exclusively in milk with a high T(h)2 adjuvant activity. The mass is exactly that of Coenzyme A (CoA), and indeed, a low concentration of CoA exhibited T(h)2 adjuvant activity both in vitro and in vivo. Moreover, mesenteric lymph node non-T cells obtained from mice that were orally treated with CoA led allogeneic naive CD4(+) T cells to differentiate into T(h)2. Furthermore, the oral administration of CoA induced rough skin, hyperplasia of the epidermis, hypergranulosis in the spinous layer and the thickening of the stratum in mice. These data collectively indicate that some of the patients with AD were exposed to mothers' milk carrying high T(h)2 adjuvant activity right after birth, which may be attributable to presence of CoA contained in the milk.

  5. Abnormalities of the axial and proximal appendicular skeleton in adults with Laron syndrome (growth hormone insensitivity).

    PubMed

    Kornreich, L; Konen, O; Schwarz, M; Siegel, Y; Horev, G; Hershkovitz, I; Laron, Z

    2008-02-01

    To investigate abnormalities in the skeleton (with the exclusion of the skull, cervical spine, hands and feet) in patients with Laron syndrome, who have an inborn growth hormone resistance and congenital insulin-like growth factor-1 (IGF-1) deficiency. The study group was composed of 15 untreated patients with Laron syndrome (seven male and eight female) aged 21-68 years. Plain films of the axial and appendicular skeleton were evaluated retrospectively for abnormalities in structure and shape. The cortical width of the long bones was evaluated qualitatively and quantitatively (in the upper humerus and mid-femur), and the cortical index was calculated and compared with published references. Measurements were taken of the mid-anteroposterior and cranio-caudal diameters of the vertebral body and spinous process at L3, the interpedicular distance at L1 and L5, and the sacral slope. Thoracic and lumbar osteophytes were graded on a 5-point scale. Values were compared with a control group of 20 healthy persons matched for age. The skeleton appeared small in all patients. No signs of osteopenia were visible. The cortex of the long bones appeared thick in the upper limbs in 11 patients and in the lower limbs in four. Compared with the reference values, the cortical width was thicker than average in the humerus and thinner in the femur. The vertebral diameters at L3 and the interpedicular distances at L1 and L5 were significantly smaller in the patients than in the control subjects (P<0.001); however, at L5 the canal was wider, relative to the vertebral body. The study group had a higher rate of anterior osteophytes in the lumbar spine than the controls had, and their osteophytes were also significantly larger. In the six patients for whom radiographs of the upper extremity in its entirety were available on one film, the ulna appeared to be rotated. In one 22-year-old man, multiple epiphyses were still open. Congenital IGF-1 deficiency leads to skeletal abnormalities characterized by small bones, narrow spinal canal, and delayed bone age. The limitation in elbow distensibility common to patients with Laron syndrome may be related to a marked retroversion of the humeral head.

  6. Cyclosporin A-induced gingival overgrowth in the rat: a histological, ultrastructural and histomorphometric evaluation.

    PubMed

    Ayanoglou, C M; Lesty, C

    1999-01-01

    This investigation was undertaken to further study cyclosporin A (CsA)-induced gingival overgrowth. Thirty mg/kg/d of vehicle or CsA solutions were given orally to 6-wk-old male Sprague-Dawley rats. After 4, 9, 14 and 19 wk 2 control and 2 experimental rats were anaesthetized, tissues fixed by intracardiac perfusion of fixative solution and jaws processed for Epon inclusion. Histological and ultrastructural studies conducted in a gingival portion (free gingiva) revealed the presence of hyalinization areas and of multinucleated cells (MCs) containing collagen fibrils (connective tissue), of amorphous areas and disorders of keratinization (epithelia). Histomorphometric evaluation indicated that in the CsA rats the mean cross-sectional area of the free gingiva was 2.52-fold increased compared to the controls. The connective tissue comprised 41.43% of this area (instead of 31.49% in controls). Additional histomorphometric evaluation was performed in 3 groups of free gingival portions: control (C group), CsA-non-respondent (CsA-nR) and CsA-respondent (CsA-R). The cross-sectional gingival areas studied were slightly lower than the mean area of all the control sites previously defined (groups C and CsA-nR) or showed the higher degrees of enlargement (CsA-R). In the CsA-R group the mean cross-sectioned area of the vessel profiles was increased and the number of fibroblast profiles decreased. In the CsA-nR group the number of vessel profiles and that of MCs profiles were increased. In the epithelia of the CsA-R group were increased (a) keratinized epithelia: thickness; thickness of the inner and of the outer compartments; surface area of spinous cell profiles; (b) oral gingival epithelium: number of cell layers (inner compartment); (c) oral sulcular epithelium: surface area of granular cell profiles; (d) junctional epithelium: thickness; number of cell layers. These results indicate that (a) the CsA induced modifications are not limited to enlarged gingiva (b) the overgrowth of the GCT is the result of a vasodilatation and of an increase in the volume of the extracellular matrix and (c) the increase of the epithelial thickness is mainly the result of a cell hypertrophy in the keratinized epithelia and of a cell hyperplasia in the junctional epithelium.

  7. The immediate effect of traditional Malay massage on substance P, inflammatory mediators, pain scale and functional outcome among patients with low back pain: study protocol of a randomised controlled trial.

    PubMed

    Sejari, Nurhanisah; Kamaruddin, Kamaria; Ramasamy, Kalavathy; Lim, Siong Meng; Neoh, Chin Fen; Ming, Long Chiau

    2016-01-15

    The treatment of low back pain is very challenging due to the recurrent nature of the problem. It is believed that traditional Malay massage helps to relieve such back pain but there is a lack of scientific evidence to support both the practice of traditional Malay massage and the mechanism by which it exerts its effect. The aim of this study is to investigate the immediate effect of traditional Malay massage on the pain scale, substance P, inflammatory mediators, and functional outcomes among low back pain patients. A non-blinded, randomised controlled trial will be conducted. A total of sixty-six patients who fulfil the inclusion criteria will be recruited. The participants will be randomly allocated into intervention (traditional Malay massage) and control (relaxation position) groups. Blood and saliva samples will be collected before and immediately after intervention. All collected samples will be analysed. The primary outcomes are the changes in the level of substance P in both saliva and blood samples between both groups. The secondary outcomes include the levels of inflammatory mediators [i.e. TNF-α, IL-1β, IL-8, monocyte chemotactic protein-1, IL-6 and IL-10, and the soluble form of the intercellular adhesion molecule], the pain intensity as measured by a visual analogous scale and functional outcomes using the Roland-Morris Disability Questionnaire. Massage is a type of physical therapy that has been proven to be potentially capable of reducing unpleasant pain sensations by a complex sensory response and chemical mediators such as substance P and various inflammatory mediators. Previous studies conducted using Thai, Swedish, or other forms of massage therapies, have showed inconsistent findings on substance P levels pre and post the interventions. Each massage genre varies in terms of massage and joint mobilization points, as well as the lumbar spinous process. Traditional Malay massage, known locally as "Urut Melayu", involves soft-tissue manipulation of the whole body applied using the hands and fingers. This massage technique combines both deep muscular tissue massage and spiritual rituals. This trial is expected to give rise to new knowledge underlying the mechanisms for pain and inflammation relief that are activated by traditional Malay massage. Australian New Zealand Clinical Trials ACTRN12615000537550 .

  8. Prediction of posterior ligamentous complex injury in thoracolumbar fractures using non-MRI imaging techniques.

    PubMed

    Rajasekaran, Shanmuganathan; Maheswaran, Anupama; Aiyer, Siddharth N; Kanna, Rishi; Dumpa, Srikanth Reddy; Shetty, Ajoy Prasad

    2016-06-01

    We aimed to formulate a radiological index based on plain radiographs and computer tomography (CT) to reliably detect posterior ligamentous complex (PLC) injury without need for MRI. Sixty out of 148 consecutive thoracolumbar fractures with doubtful PLC were assessed with MRI, CT and radiographs. PLC injury was assessed with the following radiological parameters: superior-inferior end plate angle (SIEA), vertebral body height (BH), local kyphosis (LK), inter-spinous distance (ISD) and inter-pedicular distance (IPD) and correlated with MRI findings of PLC injury. Statistical analysis was performed to identify the predictive values for the parameters to identify PLC damage. MRI identified PLC injury in 25/60 cases. The ISD and LK were found to be significant predictors of PLC injury. On radiographs the mean LK with PLC damage was 25.86° compared to 21.02° with an intact PLC (p = 0.006). The ISD difference was 6.70 mm in cases with PLC damage compared to 2.86 mm with an intact PLC (p = 0.011). In CT images, the mean LK with PLC damage was 22.96° compared to 18.44° with an intact PLC ( p = 0.019). The ISD difference was 3.10 mm with PLC damage compared to 1.62 mm without PLC damage (p = 0.005). On plain radiographs the presence of LK greater than 20 °(CI 64-95) and ISD difference greater than 2 mm (CI 70-97) can predict PLC injury. These guidelines may be utilised in the emergency room especially when the associated cost, availability and time delay in performing MRI are a concern.

  9. NR2A- and NR2B-NMDA receptors and drebrin within postsynaptic spines of the hippocampus correlate with hunger-evoked exercise.

    PubMed

    Chen, Yi-Wen; Actor-Engel, Hannah; Sherpa, Ang Doma; Klingensmith, Lauren; Chowdhury, Tara G; Aoki, Chiye

    2017-07-01

    Hunger evokes foraging. This innate response can be quantified as voluntary wheel running following food restriction (FR). Paradoxically, imposing severe FR evokes voluntary FR, as some animals choose to run rather than eat, even during limited periods of food availability. This phenomenon, called activity-based anorexia (ABA), has been used to identify brain changes associated with FR and excessive exercise (EX), two core symptoms of anorexia nervosa (AN), and to explore neurobiological bases of AN vulnerability. Previously, we showed a strong positive correlation between suppression of FR-evoked hyperactivity, i.e., ABA resilience, and levels of extra-synaptic GABA receptors in stratum radiatum (SR) of hippocampal CA1. Here, we tested for the converse: whether animals with enhanced expression of NMDA receptors (NMDARs) exhibit greater levels of FR-evoked hyperactivity, i.e., ABA vulnerability. Four groups of animals were assessed for NMDAR levels at CA1 spines: (1) ABA, in which 4 days of FR was combined with wheel access to allow voluntary EX; (2) FR only; (3) EX only; and (4) control (CON) that experienced neither EX nor FR. Electron microscopy revealed that synaptic NR2A-NMDARs and NR2B-NMDARs levels are significantly elevated, relative to CONs'. Individuals' ABA severity, based on weight loss, correlated with synaptic NR2B-NMDAR levels. ABA resilience, quantified as suppression of hyperactivity, correlated strongly with reserve pools of NR2A-NMDARs in spine cytoplasm. NR2A- and NR2B-NMDAR measurements correlated with spinous prevalence of an F-actin binding protein, drebrin, suggesting that drebrin enables insertion of NR2B-NMDAR to and retention of NR2A-NMDARs away from synaptic membranes, together influencing ABA vulnerability.

  10. Neocortical layers I and II of the hedgehog (Erinaceus europaeus). I. Intrinsic organization.

    PubMed

    Valverde, F; Facal-Valverde, M V

    1986-01-01

    The intrinsic organization and interlaminar connections in neocortical layers I and II have been studied in adult hedgehogs (Erinaceus europaeus) using the Golgi method. Layer I contains a dense plexus of horizontal fibers, the terminal dendritic bouquets of pyramidal cells of layer II and of underlying layers, and varieties of intrinsic neurons. Four main types of cells were found in layer I. Small horizontal cells represent most probably persisting foetal horizontal cells described for other mammals. Large horizontal cells, tufted cells, and spinous horizontal cells were also found in this layer. Layer II contains primitive pyramidal cells representing the most outstanding feature of the neocortex of the hedgehog. Most pyramidal cells in layer II have two, three or more apical dendrites, richly covered by spines predominating over the basal dendrites. These cells resemble pyramidal cells found in the piriform cortex, hippocampus and other olfactory areas. It is suggested that the presence of these neurons reflects the retention of a primitive character in neocortical evolution. Cells with intrinsic axons were found among pyramidal cells in layer II. These have smooth dendrites penetrating layer I and local axons forming extremely complex terminal arborizations around the bodies and proximal dendritic portions of pyramidal cells. They most probably effect numerous axo-somatic contacts resembling basket cells. The similarity of some axonal terminals with the chandelier type of axonal arborization is discussed. Other varieties of cells located in deep cortical layers and having ascending axons for layers I and II were also studied. It is concluded that the two first neocortical layers represent a level of important integration in this primitive mammal.

  11. Acquisition and expression of conditioned taste aversion differentially affects extracellular signal regulated kinase and glutamate receptor phosphorylation in rat prefrontal cortex and nucleus accumbens

    PubMed Central

    Marotta, Roberto; Fenu, Sandro; Scheggi, Simona; Vinci, Stefania; Rosas, Michela; Falqui, Andrea; Gambarana, Carla; De Montis, M. Graziella; Acquas, Elio

    2014-01-01

    Conditioned taste aversion (CTA) can be applied to study associative learning and its relevant underpinning molecular mechanisms in discrete brain regions. The present study examined, by immunohistochemistry and immunocytochemistry, the effects of acquisition and expression of lithium-induced CTA on activated Extracellular signal Regulated Kinase (p-ERK) in the prefrontal cortex (PFCx) and nucleus accumbens (Acb) of male Sprague-Dawley rats. The study also examined, by immunoblotting, whether acquisition and expression of lithium-induced CTA resulted in modified levels of phosphorylation of glutamate receptor subunits (NR1 and GluR1) and Thr34- and Thr75-Dopamine-and-cAMP-Regulated PhosphoProtein (DARPP-32). CTA acquisition was associated with an increase of p-ERK-positive neurons and phosphorylated NR1 receptor subunit (p-NR1) in the PFCx, whereas p-GluR1, p-Thr34- and p-Thr75-DARPP-32 levels were not changed in this brain region. CTA expression increased the number of p-ERK-positive neurons in the shell (AcbSh) and core (AcbC) but left unmodified p-NR1, p-GluR1, p-Thr34- and p-Thr75-DARPP-32 levels. Furthermore, post-embedding immunogold quantitative analysis in AcbSh revealed that CTA expression significantly increased nuclear p-ERK immunostaining as well as p-ERK-labeled axo-spinous contacts. Overall, these results indicate that ERK and NR1, but not GluR1 and DARPP-32, are differentially phosphorylated as a consequence of acquisition and expression of aversive associative learning. Moreover, these results confirm that CTA represents an useful approach to study the molecular basis of associative learning in rats and suggest the involvement of ERK cascade in learning-associated synaptic plasticity. PMID:24847227

  12. Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection.

    PubMed

    Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon

    2015-01-01

    Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success rate of sacroiliac intraarticular injections with the upper one-third joint technique was 90% (18/20). This was an observational study and lacked a control group. Sacroiliac intraarticular injections with the upper one-third joint technique are advisable when it is hard to perform them with the lower one-third joint technique.

  13. The effect of vehicle protection on spine injuries in military conflict.

    PubMed

    Possley, Daniel R; Blair, James A; Freedman, Brett A; Schoenfeld, Andrew J; Lehman, Ronald A; Hsu, Joseph R

    2012-09-01

    To evaluate the effect of critical time periods in vehicle protection on spine injuries in the Global War on Terror. To characterize the effect of method of movement on and around the battlefield during Operation Enduring Freedom and Operation Iraqi Freedom from 2001 to 2009 in terms of its impact on the incidence and severity of spinal fractures sustained in combat. Retrospective study. Mounted and dismounted American servicemembers who were injured during combat. Extracted medical records of servicemembers identified in the Joint Theater Trauma Registry from October 2001 to December 2009. Methods of movement were defined as mounted or dismounted. Two time periods were compared. Cohorts were created for 2×2 analysis based on method of movement and the time period in which the injury occurred. Time period 1 and 2 were separated by April 1, 2007, which correlates with the initial fielding of the modern class of uparmored fighting vehicles with thickened underbelly armor and a V-shaped hull. Our four comparison groups were Dismounted in Time Period 1 (D1), Dismounted in Time Period 2 (D2), Mounted in Time Period 1 (M1), and Mounted in Time Period 2 (M2). In total, 1,819 spine fractures occurred over the entire study period. Four hundred seventy-two fractures (26%) were sustained in 145 servicemembers who were mounted at the time of injury, and 1,347 (74%) were sustained by 404 servicemembers who were dismounted (p<.0005). The incidence of fractures in the dismounted cohort (D1+D2) was significantly higher than in the mounted cohort (M1+M2) in both time periods (D1 vs. M1, 13.75 vs. 3.95/10,000 warrior-years [p<.001] and D2 vs. M2, 11.15 vs. 4.89/10,000 warrior-years [p<.0001]). In both the mounted and dismounted groups, the thoracolumbar (TL) junction was the most common site of injury (36.1%). Fractures to the TL junction (T10-L3) increased significantly from Time Period 1 to 2 (34% vs. 40% of all fractures, respectively, p=.03). Thoracolumbar fractures were significantly more severe in that there were more Arbeitsgemeinschaft fur Osteosynthesefragen/Magerl Type A injuries versus all TL fractures, 1.75 versus 2.68/10,000 or 27% of all spine fractures in Time Period 1 versus 40% in Time Period 2 (p=.007). Furthermore, there were significantly fewer minor fractures (spinous process and transverse process fractures) (p<.0001). In Time Period 2, significantly more TL spine fractures were classified as major fractures, according to the Denis classification system, in both the mounted and dismounted groups; M1 group, 61 of 226 (27%) versus the M2 group, 86 of 246 (34%) (p<.0005) and 173 of 786 (22%) in the D1 group versus 193 of 561 (34%) in the D2 group. The spinal cord injury (SCI) incidence did not change in the mounted groups in Time Period 1 (7 of 71, 9.9%) versus Time Period 2 (7 of 74, 9.5%) (p=.935). In the dismounted groups, SCI actually decreased from D1 (55 of 228, 24%) to D2 (28 of 176, 16%) (p=.0428). The incidence of spine fractures and SCI is significantly higher in dismounted operations. The data suggest that current uparmored vehicles convey greater protection against spinal fracture compared with dismounted operations in which servicemembers are engaged on foot, outside their vehicles. The TL junction is at greatest risk for spine fractures sustained in mounted and dismounted combat operations. Recently, the incidence of TL fractures, especially severe fractures, has significantly increased in mounted operations. Although there has been an increased incidence of TL spine fractures, in context of the number of servicemembers deployed in support of Operation Enduring Freedom/Operation Iraqi Freedom, these severe fractures still represent a relatively rare event. Published by Elsevier Inc.

  14. Rejuvenation of aged pig facial skin by transplanting allogeneic granulocyte colony-stimulating factor-induced peripheral blood stem cells from a young pig.

    PubMed

    Harn, Horng-Jyh; Huang, Mao-Hsuan; Huang, Chi-Ting; Lin, Po-Cheng; Yen, Ssu-Yin; Chou, Yi-Wen; Ho, Tsung-Jung; Chu, Hen-Yi; Chiou, Tzyy-Wen; Lin, Shinn-Zong

    2013-01-01

    Following a stroke, the administration of stem cells that have been treated with granulocyte colony-stimulating factor (GCSF) can ameliorate functional deficits in both rats and humans. It is not known, however, whether the application of GCSF-mobilized peripheral blood stem cells (PBSCs) to human skin can function as an antiaging treatment. We used a Lanyu pig (Sus scrofa) model, since compared with rodents, the structure of a pig's skin is very similar to human skin, to provide preliminary data on whether these cells can exert antiaging effects over a short time frame. GCSF-mobilized PBSCs from a young male Lanyu pig (5 months) were injected intradermally into the cheek skin of aged female Lanyu pigs, and tissues before and after the cell injections were compared to determine whether this treatment caused skin rejuvenation. Increased levels of collagen, elastin, hyaluronic acid, and the hyaluronic acid receptor CD44 were observed in both dermal and subcutaneous layers following the injection of PBSCs. In addition, the treated skin tissue was tighter and more elastic than adjacent control regions of aged skin tissue. In the epidermal layer, PBSC injection altered the levels of both involucrin and integrin, indicating an increased rate of epidermal cell renewal as evidenced by reductions in both cornified cells and cells of the spinous layers and increases in the number of dividing cells within the basal layer. We found that the exogenous PBSCs, visualized using fluorescence in situ hybridization, were located primarily in hair follicles and adjacent tissues. In summary, PBSC injection restored young skin properties in the skin of aged (90 months) pigs. On the basis of our preliminary data, we conclude that intradermal injection of GCSF-mobilized PBSCs from a young pig can rejuvenate the skin in aged pigs.

  15. Confocal Laser Scanning Microscopy and Ultrastructural Study of VGLUT2 Thalamic Input to Striatal Projection Neurons in Rats

    PubMed Central

    Lei, Wanlong; Deng, Yunping; Liu, Bingbing; Mu, Shuhua; Guley, Natalie M.; Wong, Ting; Reiner, Anton

    2014-01-01

    We examined thalamic input to striatum in rats using immunolabeling for the vesicular glutamate transporter (VGLUT2). Double immunofluorescence viewed with confocal laser scanning microscopy (CLSM) revealed that VGLUT2+ terminals are distinct from VGLUT1+ terminals. CLSM of Phaseolus vulgaris-leucoagglutinin (PHAL)-labeled cortical or thalamic terminals revealed that VGLUT2 is rare in corticostriatal terminals but nearly always present in thalamostriatal terminals. Electron microscopy revealed that VGLUT2+ terminals made up 39.4% of excitatory terminals in striatum (with VGLUT1+ corticostriatal terminals constituting the rest), and 66.8% of VGLUT2+ terminals synapsed on spines and the remainder on dendrites. VGLUT2+ axo-spinous terminals had a mean diameter of 0.624 lm, while VGLUT2+ axodendritic terminals a mean diameter of 0.698 µm. In tissue in which we simultaneously immunolabeled thalamostriatal terminals for VGLUT2 and striatal neurons for D1 (with about half of spines immunolabeled for D1), 54.6% of VGLUT2+ terminals targeted D1+ spines (i.e., direct pathway striatal neurons), and 37.3% of D1+ spines received VGLUT2+ synaptic contacts. By contrast, 45.4% of VGLUT2+ terminals targeted D1-negative spines (i.e., indirect pathway striatal neurons), and only 25.8% of D1-negative spines received VGLUT2+ synaptic contacts. Similarly, among VGLUT2+ axodendritic synaptic terminals, 59.1% contacted D1+ dendrites, and 40.9% contacted D1-negative dendrites. VGLUT2+ terminals on D1+ spines and dendrites tended to be slightly smaller than those on D1-negative spines and dendrites. Thus, thala-mostriatal terminals contact both direct and indirect pathway striatal neurons, with a slight preference for direct. These results are consistent with physiological studies indicating slightly different effects of thalamic input on the two types of striatal projection neurons. PMID:23047588

  16. Normative 3D opto-electronic stereo-photogrammetric posture and spine morphology data in young healthy adult population

    PubMed Central

    2017-01-01

    Design: Observational cross-sectional study. The current study aims to yield normative data: i.e., the physiological standard for 30 selected quantitative 3D parameters that accurately capture and describe a full-skeleton, upright-standing attitude. Specific and exclusive consideration was given to three distinct categories: postural, spine morphology and pelvic parameters. To capture such 3D parameters, the authors selected a non-ionising 3D opto-electronic stereo-photogrammetric approach. This required the identification and measurement of 27 body landmarks, each specifically tagged with a skin marker. As subjects for the measurement of these parameters, a cohort of 124 asymptomatic young adult volunteers was recruited. All parameters were identified and measured within this group. Postural and spine morphology data have been compared between genders. In this regard, only five statistically significant differences were found: pelvis width, pelvis torsion, the “lumbar” lordosis angle value, the lumbar curve length, and the T12-L5 anatomically-bound lumbar angle value. The “thoracic” kyphosis mean angle value was the same in both sexes and, even if, derived from skin markers placed on spinous processes it resulted in perfect agreement with the X-ray based literature. As regards lordosis, a direct comparison was more difficult because methods proposed in the literature differ as to the number and position of vertebrae under consideration, and their related angle values. However, when the L1 superior–L5 inferior end plate Cobb angle was considered, these results aligned strongly with the existing literature. Asymmetry was a standard postural-spinal feature for both sexes. Each subject presented some degree of leg length discrepancy (LLD) with μ = 9.37mm. This was associated with four factors: unbalanced posture and/or underfoot loads, spinal curvature in the frontal plane, and pelvis torsion. This led to the additional study of the effect of LLD equalisation influence on upright posture, relying on a sub-sample of 100 subjects (51 males, 49 females). As a result of the equalisation, about 82% of this sub-sample showed improvement in standing posture, mainly in the frontal plane; while in the sagittal plane less than 1/3 of the sub-sample showed evidence of change in spinal angles. A significant variation was found in relation to pelvis torsion: 46% of subjects showed improvement, 49% worsening. The method described in study presents several advantages: non-invasive aspect; relatively short time for a complete postural evaluation with many clinically useful 3D and 2D anatomical/biomechanical/clinical parameters; analysis of real neutral unconstrained upright standing posture. PMID:28640899

  17. Structural and functional characteristics of the thoracolumbar multifidus muscle in horses.

    PubMed

    García Liñeiro, J A; Graziotti, G H; Rodríguez Menéndez, J M; Ríos, C M; Affricano, N O; Victorica, C L

    2017-03-01

    The multifidus muscle fascicles of horses attach to vertebral spinous processes after crossing between one to six metameres. The fascicles within one or two metameres are difficult to distinguish in horses. A vertebral motion segment is anatomically formed by two adjacent vertebrae and the interposed soft tissue structures, and excessive mobility of a vertebral motion segment frequently causes osteoarthropathies in sport horses. The importance of the equine multifidus muscle as a vertebral motion segment stabilizer has been demonstrated; however, there is scant documentation of the structure and function of this muscle. By studying six sport horses postmortem, the normalized muscle fibre lengths of the the multifidus muscle attached to the thoracic (T)4, T9, T12, T17 and lumbar (L)3 vertebral motion segments were determined and the relative areas occupied by fibre types I, IIA and IIX were measured in the same muscles after immunohistochemical typying. The values for the normalized muscle fibre lengths and the relative areas were analysed as completely randomized blocks using an anova (P ≤ 0.05). The vertebral motion segments of the T4 vertebra include multifidus bundles extending between two and eight metameres; the vertebral motion segments of the T9, T12, T17 and L3 vertebrae contain fascicles extending between two and four metameres The muscle fibres with high normalized lengths that insert into the T4 (three and eight metameres) vertebral motion segment tend to have smaller physiological cross-sectional areas, indicating their diminished capacity to generate isometric force. In contrast, the significantly decreased normalized muscle fibre lengths and the increased physiological cross-sectional areas of the fascicles of three metameres with insertions on T9, T17, T12, L3 and the fascicles of four metameres with insertions on L3 increase their capacities to generate isometric muscle force and neutralize excessive movements of the vertebral segments with great mobility. There were no significant differences in the values of relative areas occupied by fibre types I, IIA and IIX. In considering the relative areas occupied by the fibre types in the multifidus muscle fascicles attached to each vertebral motion segment examined, the relative area occupied by the type I fibres was found to be significantly higher in the T4 vertebral motion segment than in the other segments. It can be concluded that the equine multifidus muscle in horses is an immunohistochemically homogeneous muscle with various architectural designs that have functional significance according to the vertebral motion segments considered. The results obtained in this study can serve as a basis for future research aimed at understanding the posture and dynamics of the equine spine. © 2016 Anatomical Society.

  18. [Novel artificial lamina for prevention of epidural adhesions after posterior cervical laminectomy].

    PubMed

    Lü, Chaoliang; Song, Yueming; Liu, Hao; Liu, Limin; Gong, Quan; Li, Tao; Zeng, Jiancheng; Kong, Qingquan; Pei, Fuxing; Tu, Chongqi; Duan, Hong

    2013-07-01

    To evaluate the application of artificial lamina of multi-amino-acid copolymer (MAACP)/nano-hydroxyapatite (n-HA) in prevention of epidural adhesion and compression of scar tissue after posterior cervical laminectomy. Fifteen 2-year-old male goats [weighing, (30 +/- 2) kg] were randomly divided into experimental group (n=9) and control group (n=6). In the experimental group, C4 laminectomy was performed, followed by MAACP/n-HA artificial lamina implantations; in the control group, only C4 laminectomy was performed. At 4, 12, and 24 weeks after operation, 2, 2, and 5 goats in the experimental group and 2, 2, and 2 goats in the control group were selected for observation of wound infection, artificial laminar fragmentation and displacement, and its shape; Rydell's degree of adhesion criteria was used to evaluate the adhesion degree between 2 groups. X-ray and CT images were observed; at 24 weeks after operation, CT scan was used to measure the spinal canal area and the sagittal diameter of C3, C4, and C5 vertebrea, 2 normal goats served as normal group; and MRI was used to assess adhesion and compression of scar tissue on the dura and the nerve root. Then goats were sacrificed and histological observation was carried out. After operation, the wound healed well; no toxicity or elimination reaction was observed. According to Rydell's degree of adhesion criteria, adhesion in the experimental group was significantly slighter than that in the control group (Z= -2.52, P=0.00). X-ray and CT scan showed that no dislocation of artificial lamina occurred, new cervical bone formed in the defect, and bony spinal canal was rebuilt in the experimental group. Defects of C4 vertebral plate and spinous process were observed in the control group. At 24 weeks, the spinal canal area and sagittal diameter of C4 in the experimental group and normal group were significantly larger than those in the control group (P < 0.05), but no significant difference was found between experimental group and normal group (P > 0.05). MRI showed cerebrospinal fluid signal was unobstructed and no soft tissue projected into the spinal canal in the experimental group; scar tissue projected into the spinal canal and the dura were compressed by scar tissue in the control group. HE staining and Masson trichrome staining showed that artificial lamina had no obvious degradation with high integrity, some new bone formed at interface between the artificial material and bone in the experimental group; fibrous tissue grew into defect in the control group. The MAACP/n-HA artificial lamina could maintaine good biomechanical properties for a long time in vivo and could effectively prevent the epidural scar from growing in the lamina defect area.

  19. Distraction of facets with intraarticular spacers as treatment for lumbar canal stenosis: report on a preliminary experience with 21 cases.

    PubMed

    Goel, Atul; Shah, Abhidha; Jadhav, Madan; Nama, Santhosh

    2013-12-01

    The authors report their experience in treating 21 patients by using a novel form of treatment of lumbar degenerative disease that leads to canal stenosis. The surgery involved distraction of the facets using specially designed Goel intraarticular spacers and was aimed at arthrodesis of the spinal segment in a distracted position. The operation is based on the premise that subtle and longstanding facet instability, joint space reduction, and subsequent facet override had a profound and primary influence in the pathogenesis of degenerative lumbar canal stenosis. The surgical technique and the rationale for treatment are discussed. Between April 2006 and January 2011, 21 cases of lumbar degenerative disease resulting in characteristic lumbar canal stenosis were treated in the authors' department with the proposed technique. The patients were prospectively analyzed. There were 15 men and 6 women who ranged in age from 48 to 71 years (mean 58 years). Nine patients underwent 1-level and 12 patients underwent 2-level treatment. Surgery involved wide opening of the articular joint, denuding of the articular capsule/endplate cartilage, distraction of the facets, and forced impaction of Goel intraarticular spacers. Bone graft pieces obtained by sectioning the spinous processes were placed within and over the joint and in the midline over the adequately prepared host area of laminae. The Oswestry Disability Index and visual analog scale were used to clinically assess the patients before and after surgery and at follow-up. The alterations in the physical architecture of spinal canal and intervertebral foramen dimensions were evaluated before and after placement of the intrafacet implant and after at least 6 months of follow-up. All patients had varying degrees of relief from symptoms of local back pain and radiculopathy. Impaction of spacers within the facet joints resulted in an increase in the spinal canal and intervertebral root canal dimensions (mean 2.33 mm), reduction of buckling of the ligamentum flavum, and reduction of the extent of bulge of the disc into the spinal canal. The procedure resulted in firm stabilization and fixation of the spinal segment and provided a ground for arthrodesis. No patient worsened neurologically after treatment. During the follow-up period, all patients had evidence of segmental bone fusion. No patient underwent reexploration or further surgery of the lumbar spine. Impaction of the spacers within the articular cavity after facet distraction resulted in reversal of several effects of spine degeneration that had caused spinal and root canal stenosis. The safe, firm, and secure stabilization at the fulcrum of lumbar spinal movements provided a ground for segmental spinal arthrodesis. The immediate postoperative and lasting recovery from symptoms suggests the validity of the procedure.

  20. Impact of Radio Frequency Identification (RFID) on the Marine Corps’ Supply Process

    DTIC Science & Technology

    2006-09-01

    Hypothetical Improvement Using a Real-Time Order Processing System Vice a Batch Order Processing System ................56 3. As-Is: The Current... Processing System Vice a Batch Order Processing System ................58 V. RESULTS ................................................69 A. SIMULATION...Time: Hypothetical Improvement Using a Real-Time Order Processing System Vice a Batch Order Processing System ................71 3. As-Is: The

  1. Development of a Full-Thickness Human Skin Equivalent In Vitro Model Derived from TERT-Immortalized Keratinocytes and Fibroblasts

    PubMed Central

    Reijnders, Christianne M.A.; van Lier, Amanda; Roffel, Sanne; Kramer, Duco; Scheper, Rik J.

    2015-01-01

    Currently, human skin equivalents (HSEs) used for in vitro assays (e.g., for wound healing) make use of primary human skin cells. Limitations of primary keratinocytes and fibroblasts include availability of donor skin and donor variation. The use of physiologically relevant cell lines could solve these limitations. The aim was to develop a fully differentiated HSE constructed entirely from human skin cell lines, which could be applied for in vitro wound-healing assays. Skin equivalents were constructed from human TERT-immortalized keratinocytes and fibroblasts (TERT-HSE) and compared with native skin and primary HSEs. HSEs were characterized by hematoxylin–eosin and immunohistochemical stainings with markers for epidermal proliferation and differentiation, basement membrane (BM), fibroblasts, and the extracellular matrix (ECM). Ultrastructure was determined with electron microscopy. To test the functionality of the TERT-HSE, burn and cold injuries were applied, followed by immunohistochemical stainings, measurement of reepithelialization, and determination of secreted wound-healing mediators. The TERT-HSE was composed of a fully differentiated epidermis and a fibroblast-populated dermis comparable to native skin and primary HSE. The epidermis consisted of proliferating keratinocytes within the basal layer, followed by multiple spinous layers, a granular layer, and cornified layers. Within the TERT-HSE, the membrane junctions such as corneosomes, desmosomes, and hemidesmosomes were well developed as shown by ultrastructure pictures. Furthermore, the BM consisted of a lamina lucida and lamina densa comparable to native skin. The dermal matrix of the TERT-HSE was more similar to native skin than the primary construct, since collagen III, an ECM marker, was present in TERT-HSEs and absent in primary HSEs. After wounding, the TERT-HSE was able to reepithelialize and secrete inflammatory wound-healing mediators. In conclusion, the novel TERT-HSE, constructed entirely from human cell lines, provides an excellent opportunity to study in vitro skin biology and can also be used for drug targeting and testing new therapeutics, and ultimately, for incorporating into skin-on-a chip in the future. PMID:26135533

  2. Development of a Full-Thickness Human Skin Equivalent In Vitro Model Derived from TERT-Immortalized Keratinocytes and Fibroblasts.

    PubMed

    Reijnders, Christianne M A; van Lier, Amanda; Roffel, Sanne; Kramer, Duco; Scheper, Rik J; Gibbs, Susan

    2015-09-01

    Currently, human skin equivalents (HSEs) used for in vitro assays (e.g., for wound healing) make use of primary human skin cells. Limitations of primary keratinocytes and fibroblasts include availability of donor skin and donor variation. The use of physiologically relevant cell lines could solve these limitations. The aim was to develop a fully differentiated HSE constructed entirely from human skin cell lines, which could be applied for in vitro wound-healing assays. Skin equivalents were constructed from human TERT-immortalized keratinocytes and fibroblasts (TERT-HSE) and compared with native skin and primary HSEs. HSEs were characterized by hematoxylin-eosin and immunohistochemical stainings with markers for epidermal proliferation and differentiation, basement membrane (BM), fibroblasts, and the extracellular matrix (ECM). Ultrastructure was determined with electron microscopy. To test the functionality of the TERT-HSE, burn and cold injuries were applied, followed by immunohistochemical stainings, measurement of reepithelialization, and determination of secreted wound-healing mediators. The TERT-HSE was composed of a fully differentiated epidermis and a fibroblast-populated dermis comparable to native skin and primary HSE. The epidermis consisted of proliferating keratinocytes within the basal layer, followed by multiple spinous layers, a granular layer, and cornified layers. Within the TERT-HSE, the membrane junctions such as corneosomes, desmosomes, and hemidesmosomes were well developed as shown by ultrastructure pictures. Furthermore, the BM consisted of a lamina lucida and lamina densa comparable to native skin. The dermal matrix of the TERT-HSE was more similar to native skin than the primary construct, since collagen III, an ECM marker, was present in TERT-HSEs and absent in primary HSEs. After wounding, the TERT-HSE was able to reepithelialize and secrete inflammatory wound-healing mediators. In conclusion, the novel TERT-HSE, constructed entirely from human cell lines, provides an excellent opportunity to study in vitro skin biology and can also be used for drug targeting and testing new therapeutics, and ultimately, for incorporating into skin-on-a chip in the future.

  3. [Dual process in large number estimation under uncertainty].

    PubMed

    Matsumuro, Miki; Miwa, Kazuhisa; Terai, Hitoshi; Yamada, Kento

    2016-08-01

    According to dual process theory, there are two systems in the mind: an intuitive and automatic System 1 and a logical and effortful System 2. While many previous studies about number estimation have focused on simple heuristics and automatic processes, the deliberative System 2 process has not been sufficiently studied. This study focused on the System 2 process for large number estimation. First, we described an estimation process based on participants’ verbal reports. The task, corresponding to the problem-solving process, consisted of creating subgoals, retrieving values, and applying operations. Second, we investigated the influence of such deliberative process by System 2 on intuitive estimation by System 1, using anchoring effects. The results of the experiment showed that the System 2 process could mitigate anchoring effects.

  4. System and method for deriving a process-based specification

    NASA Technical Reports Server (NTRS)

    Hinchey, Michael Gerard (Inventor); Rouff, Christopher A. (Inventor); Rash, James Larry (Inventor)

    2009-01-01

    A system and method for deriving a process-based specification for a system is disclosed. The process-based specification is mathematically inferred from a trace-based specification. The trace-based specification is derived from a non-empty set of traces or natural language scenarios. The process-based specification is mathematically equivalent to the trace-based specification. Code is generated, if applicable, from the process-based specification. A process, or phases of a process, using the features disclosed can be reversed and repeated to allow for an interactive development and modification of legacy systems. The process is applicable to any class of system, including, but not limited to, biological and physical systems, electrical and electro-mechanical systems in addition to software, hardware and hybrid hardware-software systems.

  5. 45 CFR 205.35 - Mechanized claims processing and information retrieval systems; definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... claims processing and information retrieval systems; definitions. Section 205.35 through 205.38 contain...: (a) A mechanized claims processing and information retrieval system, hereafter referred to as an automated application processing and information retrieval system (APIRS), or the system, means a system of...

  6. 45 CFR 205.35 - Mechanized claims processing and information retrieval systems; definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... claims processing and information retrieval systems; definitions. Section 205.35 through 205.38 contain...: (a) A mechanized claims processing and information retrieval system, hereafter referred to as an automated application processing and information retrieval system (APIRS), or the system, means a system of...

  7. 45 CFR 205.35 - Mechanized claims processing and information retrieval systems; definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... claims processing and information retrieval systems; definitions. Section 205.35 through 205.38 contain...: (a) A mechanized claims processing and information retrieval system, hereafter referred to as an automated application processing and information retrieval system (APIRS), or the system, means a system of...

  8. 21 CFR 111.55 - What are the requirements to implement a production and process control system?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... production and process control system? 111.55 Section 111.55 Food and Drugs FOOD AND DRUG ADMINISTRATION... to Establish a Production and Process Control System § 111.55 What are the requirements to implement a production and process control system? You must implement a system of production and process...

  9. Intelligent process development of foam molding for the Thermal Protection System (TPS) of the space shuttle external tank

    NASA Technical Reports Server (NTRS)

    Bharwani, S. S.; Walls, J. T.; Jackson, M. E.

    1987-01-01

    A knowledge based system to assist process engineers in evaluating the processability and moldability of poly-isocyanurate (PIR) formulations for the thermal protection system of the Space Shuttle external tank (ET) is discussed. The Reaction Injection Molding- Process Development Advisor (RIM-PDA) is a coupled system which takes advantage of both symbolic and numeric processing techniques. This system will aid the process engineer in identifying a startup set of mold schedules and in refining the mold schedules to remedy specific process problems diagnosed by the system.

  10. A Model of the Base Civil Engineering Work Request/Work Order Processing System.

    DTIC Science & Technology

    1979-09-01

    changes to the work order processing system. This research identifies the variables that significantly affect the accomplishment time and proposes a... order processing system and its behavior with respect to work order processing time. A conceptual model was developed to describe the work request...work order processing system as a stochastic queueing system in which the processing times and the various distributions are treated as random variables

  11. Defining and reconstructing clinical processes based on IHE and BPMN 2.0.

    PubMed

    Strasser, Melanie; Pfeifer, Franz; Helm, Emmanuel; Schuler, Andreas; Altmann, Josef

    2011-01-01

    This paper describes the current status and the results of our process management system for defining and reconstructing clinical care processes, which contributes to compare, analyze and evaluate clinical processes and further to identify high cost tasks or stays. The system is founded on IHE, which guarantees standardized interfaces and interoperability between clinical information systems. At the heart of the system there is BPMN, a modeling notation and specification language, which allows the definition and execution of clinical processes. The system provides functionality to define healthcare information system independent clinical core processes and to execute the processes in a workflow engine. Furthermore, the reconstruction of clinical processes is done by evaluating an IHE audit log database, which records patient movements within a health care facility. The main goal of the system is to assist hospital operators and clinical process managers to detect discrepancies between defined and actual clinical processes and as well to identify main causes of high medical costs. Beyond that, the system can potentially contribute to reconstruct and improve clinical processes and enhance cost control and patient care quality.

  12. Working on the Boundaries: Philosophies and Practices of the Design Process

    NASA Technical Reports Server (NTRS)

    Ryan, R.; Blair, J.; Townsend, J.; Verderaime, V.

    1996-01-01

    While systems engineering process is a program formal management technique and contractually binding, the design process is the informal practice of achieving the design project requirements throughout all design phases of the systems engineering process. The design process and organization are systems and component dependent. Informal reviews include technical information meetings and concurrent engineering sessions, and formal technical discipline reviews are conducted through the systems engineering process. This paper discusses and references major philosophical principles in the design process, identifies its role in interacting systems and disciplines analyses and integrations, and illustrates the process application in experienced aerostructural designs.

  13. Spacelab Data Processing Facility (SLDPF) quality assurance expert systems development

    NASA Technical Reports Server (NTRS)

    Basile, Lisa R.; Kelly, Angelita C.

    1987-01-01

    The Spacelab Data Processing Facility (SLDPF) is an integral part of the Space Shuttle data network for missions that involve attached scientific payloads. Expert system prototypes were developed to aid in the performance of the quality assurance function of the Spacelab and/or Attached Shuttle Payloads processed telemetry data. The Spacelab Input Processing System (SIPS) and the Spacelab Output Processing System (SOPS), two expert systems, were developed to determine their feasibility and potential in the quality assurance of processed telemetry data. The capabilities and performance of these systems are discussed.

  14. 75 FR 71376 - Simplified Network Application Processing System, On-Line Registration and Account Maintenance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-23

    ...-02] RIN 0694-AE98 Simplified Network Application Processing System, On-Line Registration and Account...'') electronically via BIS's Simplified Network Application Processing (SNAP-R) system. Currently, parties must... Network Applications Processing System (SNAP-R) in October 2006. The SNAP-R system provides a Web based...

  15. Modeling and analysis of power processing systems: Feasibility investigation and formulation of a methodology

    NASA Technical Reports Server (NTRS)

    Biess, J. J.; Yu, Y.; Middlebrook, R. D.; Schoenfeld, A. D.

    1974-01-01

    A review is given of future power processing systems planned for the next 20 years, and the state-of-the-art of power processing design modeling and analysis techniques used to optimize power processing systems. A methodology of modeling and analysis of power processing equipment and systems has been formulated to fulfill future tradeoff studies and optimization requirements. Computer techniques were applied to simulate power processor performance and to optimize the design of power processing equipment. A program plan to systematically develop and apply the tools for power processing systems modeling and analysis is presented so that meaningful results can be obtained each year to aid the power processing system engineer and power processing equipment circuit designers in their conceptual and detail design and analysis tasks.

  16. Integrating system safety into the basic systems engineering process

    NASA Technical Reports Server (NTRS)

    Griswold, J. W.

    1971-01-01

    The basic elements of a systems engineering process are given along with a detailed description of what the safety system requires from the systems engineering process. Also discussed is the safety that the system provides to other subfunctions of systems engineering.

  17. AIRSAR Automated Web-based Data Processing and Distribution System

    NASA Technical Reports Server (NTRS)

    Chu, Anhua; vanZyl, Jakob; Kim, Yunjin; Lou, Yunling; Imel, David; Tung, Wayne; Chapman, Bruce; Durden, Stephen

    2005-01-01

    In this paper, we present an integrated, end-to-end synthetic aperture radar (SAR) processing system that accepts data processing requests, submits processing jobs, performs quality analysis, delivers and archives processed data. This fully automated SAR processing system utilizes database and internet/intranet web technologies to allow external users to browse and submit data processing requests and receive processed data. It is a cost-effective way to manage a robust SAR processing and archival system. The integration of these functions has reduced operator errors and increased processor throughput dramatically.

  18. Systemic safety project selection tool.

    DOT National Transportation Integrated Search

    2013-07-01

    "The Systemic Safety Project Selection Tool presents a process for incorporating systemic safety planning into traditional safety management processes. The Systemic Tool provides a step-by-step process for conducting systemic safety analysis; conside...

  19. Design of distributed systems of hydrolithosphere processes management. A synthesis of distributed management systems

    NASA Astrophysics Data System (ADS)

    Pershin, I. M.; Pervukhin, D. A.; Ilyushin, Y. V.; Afanaseva, O. V.

    2017-10-01

    The paper considers an important problem of designing distributed systems of hydrolithosphere processes management. The control actions on the hydrolithosphere processes under consideration are implemented by a set of extractive wells. The article shows the method of defining the approximation links for description of the dynamic characteristics of hydrolithosphere processes. The structure of distributed regulators, used in the management systems by the considered processes, is presented. The paper analyses the results of the synthesis of the distributed management system and the results of modelling the closed-loop control system by the parameters of the hydrolithosphere process.

  20. On-Line Real-Time Management Information Systems and Their Impact Upon User Personnel and Organizational Structure in Aviation Maintenance Activities.

    DTIC Science & Technology

    1979-12-01

    the functional management level, a real-time production con- trol system and an order processing system at the operational level. SIDMS was designed...at any one time. 26 An overview of the major software systems in operation is listed below: a. Major Software Systems: Order processing system e Order ... processing for the supply support center/AWP locker. e Order processing for the airwing squadron material controls. e Order processing for the IMA

  1. Low level image processing techniques using the pipeline image processing engine in the flight telerobotic servicer

    NASA Technical Reports Server (NTRS)

    Nashman, Marilyn; Chaconas, Karen J.

    1988-01-01

    The sensory processing system for the NASA/NBS Standard Reference Model (NASREM) for telerobotic control is described. This control system architecture was adopted by NASA of the Flight Telerobotic Servicer. The control system is hierarchically designed and consists of three parallel systems: task decomposition, world modeling, and sensory processing. The Sensory Processing System is examined, and in particular the image processing hardware and software used to extract features at low levels of sensory processing for tasks representative of those envisioned for the Space Station such as assembly and maintenance are described.

  2. An Internationally Consented Standard for Nursing Process-Clinical Decision Support Systems in Electronic Health Records.

    PubMed

    Müller-Staub, Maria; de Graaf-Waar, Helen; Paans, Wolter

    2016-11-01

    Nurses are accountable to apply the nursing process, which is key for patient care: It is a problem-solving process providing the structure for care plans and documentation. The state-of-the art nursing process is based on classifications that contain standardized concepts, and therefore, it is named Advanced Nursing Process. It contains valid assessments, nursing diagnoses, interventions, and nursing-sensitive patient outcomes. Electronic decision support systems can assist nurses to apply the Advanced Nursing Process. However, nursing decision support systems are missing, and no "gold standard" is available. The study aim is to develop a valid Nursing Process-Clinical Decision Support System Standard to guide future developments of clinical decision support systems. In a multistep approach, a Nursing Process-Clinical Decision Support System Standard with 28 criteria was developed. After pilot testing (N = 29 nurses), the criteria were reduced to 25. The Nursing Process-Clinical Decision Support System Standard was then presented to eight internationally known experts, who performed qualitative interviews according to Mayring. Fourteen categories demonstrate expert consensus on the Nursing Process-Clinical Decision Support System Standard and its content validity. All experts agreed the Advanced Nursing Process should be the centerpiece for the Nursing Process-Clinical Decision Support System and should suggest research-based, predefined nursing diagnoses and correct linkages between diagnoses, evidence-based interventions, and patient outcomes.

  3. [Modality specific systems of representation and processing of information. Superfluous images, useful representations, necessary evil or inevitable consequences of optimal stimulus processing].

    PubMed

    Zimmer, H D

    1993-01-01

    It is discussed what is underlying the assumption of modality-specific processing systems and representations. Starting from the information processing approach relevant aspects of mental representations and their physiological realizations are discussed. Then three different forms of modality-specific systems are distinguished: as stimulus specific processing, as specific informational formats, and as modular part systems. Parallel to that three kinds of analogue systems are differentiated: as holding an analogue-relation, as having a specific informational format and as a set of specific processing constraints. These different aspects of the assumption of modality-specific systems are demonstrated in the example of visual and spatial information processing. It is concluded that postulating information-specific systems is not a superfluous assumption, but it is necessary, and even more likely it is an inevitable consequence of an optimization of stimulus processing.

  4. On the Risk Management and Auditing of SOA Based Business Processes

    NASA Astrophysics Data System (ADS)

    Orriens, Bart; Heuvel, Willem-Jan V./D.; Papazoglou, Mike

    SOA-enabled business processes stretch across many cooperating and coordinated systems, possibly crossing organizational boundaries, and technologies like XML and Web services are used for making system-to-system interactions commonplace. Business processes form the foundation for all organizations, and as such, are impacted by industry regulations. This requires organizations to review their business processes and ensure that they meet the compliance standards set forth in legislation. In this paper we sketch a SOA-based service risk management and auditing methodology including a compliance enforcement and verification system that assures verifiable business process compliance. This is done on the basis of a knowledge-based system that allows integration of internal control systems into business processes conform pre-defined compliance rules, monitor both the normal process behavior and those of the control systems during process execution, and log these behaviors to facilitate retrospective auditing.

  5. Containerless automated processing of intermetallic compounds and composites

    NASA Technical Reports Server (NTRS)

    Johnson, D. R.; Joslin, S. M.; Reviere, R. D.; Oliver, B. F.; Noebe, R. D.

    1993-01-01

    An automated containerless processing system has been developed to directionally solidify high temperature materials, intermetallic compounds, and intermetallic/metallic composites. The system incorporates a wide range of ultra-high purity chemical processing conditions. The utilization of image processing for automated control negates the need for temperature measurements for process control. The list of recent systems that have been processed includes Cr, Mo, Mn, Nb, Ni, Ti, V, and Zr containing aluminides. Possible uses of the system, process control approaches, and properties and structures of recently processed intermetallics are reviewed.

  6. Apparatus and Method for Assessing Vestibulo-Ocular Function

    NASA Technical Reports Server (NTRS)

    Shelhamer, Mark J. (Inventor)

    2015-01-01

    A system for assessing vestibulo-ocular function includes a motion sensor system adapted to be coupled to a user's head; a data processing system configured to communicate with the motion sensor system to receive the head-motion signals; a visual display system configured to communicate with the data processing system to receive image signals from the data processing system; and a gain control device arranged to be operated by the user and to communicate gain adjustment signals to the data processing system.

  7. Using ERP and WfM Systems for Implementing Business Processes: An Empirical Study

    NASA Astrophysics Data System (ADS)

    Aversano, Lerina; Tortorella, Maria

    Software systems mainly considered from enterprises for dealing with a business process automation belong to the following two categories: Workflow Management Systems (WfMS) and Enterprise Resource Planning (ERP) systems. The wider diffusion of ERP systems tends to favourite this solution, but there are several limitations of most ERP systems for automating business processes. This paper reports an empirical study aiming at comparing the ability of implementing business processes of ERP systems and WfMSs. Two different case studies have been considered in the empirical study. It evaluates and analyses the correctness and completeness of the process models implemented by using ERP and WfM systems.

  8. Image data processing system requirements study. Volume 1: Analysis. [for Earth Resources Survey Program

    NASA Technical Reports Server (NTRS)

    Honikman, T.; Mcmahon, E.; Miller, E.; Pietrzak, L.; Yorsz, W.

    1973-01-01

    Digital image processing, image recorders, high-density digital data recorders, and data system element processing for use in an Earth Resources Survey image data processing system are studied. Loading to various ERS systems is also estimated by simulation.

  9. Thermal Storage Process and Components Laboratory | Energy Systems

    Science.gov Websites

    Integration Facility | NREL Process and Components Laboratory Thermal Storage Process and Components Laboratory The Energy Systems Integration Facility's Thermal Systems Process and Components Laboratory supports research and development, testing, and evaluation of new thermal energy storage systems

  10. On Cognition, Structured Sequence Processing, and Adaptive Dynamical Systems

    NASA Astrophysics Data System (ADS)

    Petersson, Karl Magnus

    2008-11-01

    Cognitive neuroscience approaches the brain as a cognitive system: a system that functionally is conceptualized in terms of information processing. We outline some aspects of this concept and consider a physical system to be an information processing device when a subclass of its physical states can be viewed as representational/cognitive and transitions between these can be conceptualized as a process operating on these states by implementing operations on the corresponding representational structures. We identify a generic and fundamental problem in cognition: sequentially organized structured processing. Structured sequence processing provides the brain, in an essential sense, with its processing logic. In an approach addressing this problem, we illustrate how to integrate levels of analysis within a framework of adaptive dynamical systems. We note that the dynamical system framework lends itself to a description of asynchronous event-driven devices, which is likely to be important in cognition because the brain appears to be an asynchronous processing system. We use the human language faculty and natural language processing as a concrete example through out.

  11. Automated method for the systematic interpretation of resonance peaks in spectrum data

    DOEpatents

    Damiano, B.; Wood, R.T.

    1997-04-22

    A method is described for spectral signature interpretation. The method includes the creation of a mathematical model of a system or process. A neural network training set is then developed based upon the mathematical model. The neural network training set is developed by using the mathematical model to generate measurable phenomena of the system or process based upon model input parameter that correspond to the physical condition of the system or process. The neural network training set is then used to adjust internal parameters of a neural network. The physical condition of an actual system or process represented by the mathematical model is then monitored by extracting spectral features from measured spectra of the actual process or system. The spectral features are then input into said neural network to determine the physical condition of the system or process represented by the mathematical model. More specifically, the neural network correlates the spectral features (i.e. measurable phenomena) of the actual process or system with the corresponding model input parameters. The model input parameters relate to specific components of the system or process, and, consequently, correspond to the physical condition of the process or system. 1 fig.

  12. Automated method for the systematic interpretation of resonance peaks in spectrum data

    DOEpatents

    Damiano, Brian; Wood, Richard T.

    1997-01-01

    A method for spectral signature interpretation. The method includes the creation of a mathematical model of a system or process. A neural network training set is then developed based upon the mathematical model. The neural network training set is developed by using the mathematical model to generate measurable phenomena of the system or process based upon model input parameter that correspond to the physical condition of the system or process. The neural network training set is then used to adjust internal parameters of a neural network. The physical condition of an actual system or process represented by the mathematical model is then monitored by extracting spectral features from measured spectra of the actual process or system. The spectral features are then input into said neural network to determine the physical condition of the system or process represented by the mathematical. More specifically, the neural network correlates the spectral features (i.e. measurable phenomena) of the actual process or system with the corresponding model input parameters. The model input parameters relate to specific components of the system or process, and, consequently, correspond to the physical condition of the process or system.

  13. IDAPS (Image Data Automated Processing System) System Description

    DTIC Science & Technology

    1988-06-24

    This document describes the physical configuration and components used in the image processing system referred to as IDAPS (Image Data Automated ... Processing System). This system was developed by the Environmental Research Institute of Michigan (ERIM) for Eglin Air Force Base. The system is designed

  14. 42 CFR 431.834 - Access to records: Claims processing assessment systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ADMINISTRATION Quality Control Medicaid Quality Control (mqc) Claims Processing Assessment System § 431.834 Access to records: Claims processing assessment systems. The agency, upon written request, must provide HHS staff with access to all records pertaining to its MQC claims processing assessment system reviews...

  15. Development of Spreadsheet-Based Integrated Transaction Processing Systems and Financial Reporting Systems

    NASA Astrophysics Data System (ADS)

    Ariana, I. M.; Bagiada, I. M.

    2018-01-01

    Development of spreadsheet-based integrated transaction processing systems and financial reporting systems is intended to optimize the capabilities of spreadsheet in accounting data processing. The purpose of this study are: 1) to describe the spreadsheet-based integrated transaction processing systems and financial reporting systems; 2) to test its technical and operational feasibility. This study type is research and development. The main steps of study are: 1) needs analysis (need assessment); 2) developing spreadsheet-based integrated transaction processing systems and financial reporting systems; and 3) testing the feasibility of spreadsheet-based integrated transaction processing systems and financial reporting systems. The technical feasibility include the ability of hardware and operating systems to respond the application of accounting, simplicity and ease of use. Operational feasibility include the ability of users using accounting applications, the ability of accounting applications to produce information, and control applications of the accounting applications. The instrument used to assess the technical and operational feasibility of the systems is the expert perception questionnaire. The instrument uses 4 Likert scale, from 1 (strongly disagree) to 4 (strongly agree). Data were analyzed using percentage analysis by comparing the number of answers within one (1) item by the number of ideal answer within one (1) item. Spreadsheet-based integrated transaction processing systems and financial reporting systems integrate sales, purchases, and cash transaction processing systems to produce financial reports (statement of profit or loss and other comprehensive income, statement of changes in equity, statement of financial position, and statement of cash flows) and other reports. Spreadsheet-based integrated transaction processing systems and financial reporting systems is feasible from the technical aspects (87.50%) and operational aspects (84.17%).

  16. User's manual for the National Water Information System of the U.S. Geological Survey: Automated Data Processing System (ADAPS)

    USGS Publications Warehouse

    ,

    2003-01-01

    The Automated Data Processing System (ADAPS) was developed for the processing, storage, and retrieval of water data, and is part of the National Water Information System (NWIS) developed by the U.S. Geological Survey. NWIS is a distributed water database in which data can be processed over a network of computers at U.S. Geological Survey offices throughout the United States. NWIS comprises four subsystems: ADAPS, the Ground-Water Site Inventory System (GWSI), the Water-Quality System (QWDATA), and the Site-Specific Water-Use Data System (SWUDS). This section of the NWIS User's Manual describes the automated data processing of continuously recorded water data, which primarily are surface-water data; however, the system also allows for the processing of water-quality and ground-water data. This manual describes various components and features of the ADAPS, and provides an overview of the data processing system and a description of the system framework. The components and features included are: (1) data collection and processing, (2) ADAPS menus and programs, (3) command line functions, (4) steps for processing station records, (5) postprocessor programs control files, (6) the standard format for transferring and entering unit and daily values, and (7) relational database (RDB) formats.

  17. Overcoming Intuition: Metacognitive Difficulty Activates Analytic Reasoning

    ERIC Educational Resources Information Center

    Alter, Adam L.; Oppenheimer, Daniel M.; Epley, Nicholas; Eyre, Rebecca N.

    2007-01-01

    Humans appear to reason using two processing styles: System 1 processes that are quick, intuitive, and effortless and System 2 processes that are slow, analytical, and deliberate that occasionally correct the output of System 1. Four experiments suggest that System 2 processes are activated by metacognitive experiences of difficulty or disfluency…

  18. Application of the informational reference system OZhUR to the automated processing of data from satellites of the Kosmos series

    NASA Technical Reports Server (NTRS)

    Pokras, V. M.; Yevdokimov, V. P.; Maslov, V. D.

    1978-01-01

    The structure and potential of the information reference system OZhUR designed for the automated data processing systems of scientific space vehicles (SV) is considered. The system OZhUR ensures control of the extraction phase of processing with respect to a concrete SV and the exchange of data between phases.The practical application of the system OZhUR is exemplified in the construction of a data processing system for satellites of the Cosmos series. As a result of automating the operations of exchange and control, the volume of manual preparation of data is significantly reduced, and there is no longer any need for individual logs which fix the status of data processing. The system Ozhur is included in the automated data processing system Nauka which is realized in language PL-1 in a binary one-address system one-state (BOS OS) electronic computer.

  19. Design of penicillin fermentation process simulation system

    NASA Astrophysics Data System (ADS)

    Qi, Xiaoyu; Yuan, Zhonghu; Qi, Xiaoxuan; Zhang, Wenqi

    2011-10-01

    Real-time monitoring for batch process attracts increasing attention. It can ensure safety and provide products with consistent quality. The design of simulation system of batch process fault diagnosis is of great significance. In this paper, penicillin fermentation, a typical non-linear, dynamic, multi-stage batch production process, is taken as the research object. A visual human-machine interactive simulation software system based on Windows operation system is developed. The simulation system can provide an effective platform for the research of batch process fault diagnosis.

  20. Programmable partitioning for high-performance coherence domains in a multiprocessor system

    DOEpatents

    Blumrich, Matthias A [Ridgefield, CT; Salapura, Valentina [Chappaqua, NY

    2011-01-25

    A multiprocessor computing system and a method of logically partitioning a multiprocessor computing system are disclosed. The multiprocessor computing system comprises a multitude of processing units, and a multitude of snoop units. Each of the processing units includes a local cache, and the snoop units are provided for supporting cache coherency in the multiprocessor system. Each of the snoop units is connected to a respective one of the processing units and to all of the other snoop units. The multiprocessor computing system further includes a partitioning system for using the snoop units to partition the multitude of processing units into a plurality of independent, memory-consistent, adjustable-size processing groups. Preferably, when the processor units are partitioned into these processing groups, the partitioning system also configures the snoop units to maintain cache coherency within each of said groups.

  1. An Ibm PC/AT-Based Image Acquisition And Processing System For Quantitative Image Analysis

    NASA Astrophysics Data System (ADS)

    Kim, Yongmin; Alexander, Thomas

    1986-06-01

    In recent years, a large number of applications have been developed for image processing systems in the area of biological imaging. We have already finished the development of a dedicated microcomputer-based image processing and analysis system for quantitative microscopy. The system's primary function has been to facilitate and ultimately automate quantitative image analysis tasks such as the measurement of cellular DNA contents. We have recognized from this development experience, and interaction with system users, biologists and technicians, that the increasingly widespread use of image processing systems, and the development and application of new techniques for utilizing the capabilities of such systems, would generate a need for some kind of inexpensive general purpose image acquisition and processing system specially tailored for the needs of the medical community. We are currently engaged in the development and testing of hardware and software for a fairly high-performance image processing computer system based on a popular personal computer. In this paper, we describe the design and development of this system. Biological image processing computer systems have now reached a level of hardware and software refinement where they could become convenient image analysis tools for biologists. The development of a general purpose image processing system for quantitative image analysis that is inexpensive, flexible, and easy-to-use represents a significant step towards making the microscopic digital image processing techniques more widely applicable not only in a research environment as a biologist's workstation, but also in clinical environments as a diagnostic tool.

  2. An intelligent factory-wide optimal operation system for continuous production process

    NASA Astrophysics Data System (ADS)

    Ding, Jinliang; Chai, Tianyou; Wang, Hongfeng; Wang, Junwei; Zheng, Xiuping

    2016-03-01

    In this study, a novel intelligent factory-wide operation system for a continuous production process is designed to optimise the entire production process, which consists of multiple units; furthermore, this system is developed using process operational data to avoid the complexity of mathematical modelling of the continuous production process. The data-driven approach aims to specify the structure of the optimal operation system; in particular, the operational data of the process are used to formulate each part of the system. In this context, the domain knowledge of process engineers is utilised, and a closed-loop dynamic optimisation strategy, which combines feedback, performance prediction, feed-forward, and dynamic tuning schemes into a framework, is employed. The effectiveness of the proposed system has been verified using industrial experimental results.

  3. Using a Radiofrequency Identification System for Improving the Patient Discharge Process: A Simulation Study.

    PubMed

    Shim, Sung J; Kumar, Arun; Jiao, Roger

    2016-01-01

    A hospital is considering deploying a radiofrequency identification (RFID) system and setting up a new "discharge lounge" to improve the patient discharge process. This study uses computer simulation to model and compare the current process and the new process, and it assesses the impact of the RFID system and the discharge lounge on the process in terms of resource utilization and time taken in the process. The simulation results regarding resource utilization suggest that the RFID system can slightly relieve the burden on all resources, whereas the RFID system and the discharge lounge together can significantly mitigate the nurses' tasks. The simulation results in terms of the time taken demonstrate that the RFID system can shorten patient wait times, staff busy times, and bed occupation times. The results of the study could prove helpful to others who are considering the use of an RFID system in the patient discharge process in hospitals or similar processes.

  4. Application of high-throughput mini-bioreactor system for systematic scale-down modeling, process characterization, and control strategy development.

    PubMed

    Janakiraman, Vijay; Kwiatkowski, Chris; Kshirsagar, Rashmi; Ryll, Thomas; Huang, Yao-Ming

    2015-01-01

    High-throughput systems and processes have typically been targeted for process development and optimization in the bioprocessing industry. For process characterization, bench scale bioreactors have been the system of choice. Due to the need for performing different process conditions for multiple process parameters, the process characterization studies typically span several months and are considered time and resource intensive. In this study, we have shown the application of a high-throughput mini-bioreactor system viz. the Advanced Microscale Bioreactor (ambr15(TM) ), to perform process characterization in less than a month and develop an input control strategy. As a pre-requisite to process characterization, a scale-down model was first developed in the ambr system (15 mL) using statistical multivariate analysis techniques that showed comparability with both manufacturing scale (15,000 L) and bench scale (5 L). Volumetric sparge rates were matched between ambr and manufacturing scale, and the ambr process matched the pCO2 profiles as well as several other process and product quality parameters. The scale-down model was used to perform the process characterization DoE study and product quality results were generated. Upon comparison with DoE data from the bench scale bioreactors, similar effects of process parameters on process yield and product quality were identified between the two systems. We used the ambr data for setting action limits for the critical controlled parameters (CCPs), which were comparable to those from bench scale bioreactor data. In other words, the current work shows that the ambr15(TM) system is capable of replacing the bench scale bioreactor system for routine process development and process characterization. © 2015 American Institute of Chemical Engineers.

  5. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...

  6. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...

  7. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...

  8. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...

  9. 21 CFR 864.9900 - Cord blood processing system and storage container.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...

  10. Development of integrated control system for smart factory in the injection molding process

    NASA Astrophysics Data System (ADS)

    Chung, M. J.; Kim, C. Y.

    2018-03-01

    In this study, we proposed integrated control system for automation of injection molding process required for construction of smart factory. The injection molding process consists of heating, tool close, injection, cooling, tool open, and take-out. Take-out robot controller, image processing module, and process data acquisition interface module are developed and assembled to integrated control system. By adoption of integrated control system, the injection molding process can be simplified and the cost for construction of smart factory can be inexpensive.

  11. Cloud object store for checkpoints of high performance computing applications using decoupling middleware

    DOEpatents

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2016-04-19

    Cloud object storage is enabled for checkpoints of high performance computing applications using a middleware process. A plurality of files, such as checkpoint files, generated by a plurality of processes in a parallel computing system are stored by obtaining said plurality of files from said parallel computing system; converting said plurality of files to objects using a log structured file system middleware process; and providing said objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  12. Enhancement of the Acquisition Process for a Combat System-A Case Study to Model the Workflow Processes for an Air Defense System Acquisition

    DTIC Science & Technology

    2009-12-01

    Business Process Modeling BPMN Business Process Modeling Notation SoA Service-oriented Architecture UML Unified Modeling Language CSP...system developers. Supporting technologies include Business Process Modeling Notation ( BPMN ), Unified Modeling Language (UML), model-driven architecture

  13. Problems of Automation and Management Principles Information Flow in Manufacturing

    NASA Astrophysics Data System (ADS)

    Grigoryuk, E. N.; Bulkin, V. V.

    2017-07-01

    Automated control systems of technological processes are complex systems that are characterized by the presence of elements of the overall focus, the systemic nature of the implemented algorithms for the exchange and processing of information, as well as a large number of functional subsystems. The article gives examples of automatic control systems and automated control systems of technological processes held parallel between them by identifying strengths and weaknesses. Other proposed non-standard control system of technological process.

  14. A Recommended Framework for the Network-Centric Acquisition Process

    DTIC Science & Technology

    2009-09-01

    ISO /IEC 12207 , Systems and Software Engineering-Software Life-Cycle Processes  ANSI/EIA 632, Processes for Engineering a System. There are...engineering [46]. Some of the process models presented in the DAG are:  ISO /IEC 15288, Systems and Software Engineering-System Life-Cycle Processes...e.g., ISO , IA, Security, etc.). Vetting developers helps ensure that they are using industry best industry practices and maximize the IA compliance

  15. Data Acquisition and Processing System for Airborne Wind Profiling with a Pulsed, 2-Micron, Coherent-Detection, Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, J. Y.; Koch, G. J.; Kavaya, M. J.

    2010-01-01

    A data acquisition and signal processing system is being developed for a 2-micron airborne wind profiling coherent Doppler lidar system. This lidar, called the Doppler Aerosol Wind Lidar (DAWN), is based on a Ho:Tm:LuLiF laser transmitter and 15-cm diameter telescope. It is being packaged for flights onboard the NASA DC-8, with the first flights in the summer of 2010 in support of the NASA Genesis and Rapid Intensification Processes (GRIP) campaign for the study of hurricanes. The data acquisition and processing system is housed in a compact PCI chassis and consists of four components such as a digitizer, a digital signal processing (DSP) module, a video controller, and a serial port controller. The data acquisition and processing software (DAPS) is also being developed to control the system including real-time data analysis and display. The system detects an external 10 Hz trigger pulse and initiates the data acquisition and processing process, and displays selected wind profile parameters such as Doppler shift, power distribution, wind directions and velocities. Doppler shift created by aircraft motion is measured by an inertial navigation/GPS sensor and fed to the signal processing system for real-time removal of aircraft effects from wind measurements. A general overview of the system and the DAPS as well as the coherent Doppler lidar system is presented in this paper.

  16. JPRS Report, Science & Technology, Japan, High Temperature Materials

    DTIC Science & Technology

    1990-11-09

    3 This restriction is heavy. The inconvenience that the material powder of the imido thermal composition method, for example, which shows the best...procedures, system composition , features of formability, and forming characteristic of forming samples using alumina material will be made. 2...Osmotic V Process Forming System 2.1 System Composition of Process A system block diagram of the process is shown in Figure 1. The V process forming system

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zitney, S.E.

    This presentation will examine process systems engineering R&D needs for application to advanced fossil energy (FE) systems and highlight ongoing research activities at the National Energy Technology Laboratory (NETL) under the auspices of a recently launched Collaboratory for Process & Dynamic Systems Research. The three current technology focus areas include: 1) High-fidelity systems with NETL's award-winning Advanced Process Engineering Co-Simulator (APECS) technology for integrating process simulation with computational fluid dynamics (CFD) and virtual engineering concepts, 2) Dynamic systems with R&D on plant-wide IGCC dynamic simulation, control, and real-time training applications, and 3) Systems optimization including large-scale process optimization, stochastic simulationmore » for risk/uncertainty analysis, and cost estimation. Continued R&D aimed at these and other key process systems engineering models, methods, and tools will accelerate the development of advanced gasification-based FE systems and produce increasingly valuable outcomes for DOE and the Nation.« less

  18. Instrumentation for optimizing an underground coal-gasification process

    NASA Astrophysics Data System (ADS)

    Seabaugh, W.; Zielinski, R. E.

    1982-06-01

    While the United States has a coal resource base of 6.4 trillion tons, only seven percent is presently recoverable by mining. The process of in-situ gasification can recover another twenty-eight percent of the vast resource, however, viable technology must be developed for effective in-situ recovery. The key to this technology is system that can optimize and control the process in real-time. An instrumentation system is described that optimizes the composition of the injection gas, controls the in-situ process and conditions the product gas for maximum utilization. The key elements of this system are Monsanto PRISM Systems, a real-time analytical system, and a real-time data acquisition and control system. This system provides from complete automation of the process but can easily be overridden by manual control. The use of this cost effective system can provide process optimization and is an effective element in developing a viable in-situ technology.

  19. On the use of multi-agent systems for the monitoring of industrial systems

    NASA Astrophysics Data System (ADS)

    Rezki, Nafissa; Kazar, Okba; Mouss, Leila Hayet; Kahloul, Laid; Rezki, Djamil

    2016-03-01

    The objective of the current paper is to present an intelligent system for complex process monitoring, based on artificial intelligence technologies. This system aims to realize with success all the complex process monitoring tasks that are: detection, diagnosis, identification and reconfiguration. For this purpose, the development of a multi-agent system that combines multiple intelligences such as: multivariate control charts, neural networks, Bayesian networks and expert systems has became a necessity. The proposed system is evaluated in the monitoring of the complex process Tennessee Eastman process.

  20. Symptoms and signs possibly indicating segmental, discogenic pain. A fusion study with 18 years of follow-up.

    PubMed

    Nyström, Bo; Weber, Henrik; Schillberg, Birgitta; Taube, Adam

    2017-07-01

    Only two out of the five existing randomized studies have reported better results from fusion surgery for chronic low back pain (CLBP) compared to conservative treatment. In these studies the back symptoms of the patients were described simply as "chronic low back pain". One possible reason for the modest results of surgery is the lack of a description of specified symptoms that might be related to a painful segment/disc, and patient selection may therefore be more or less a matter of chance. Previous prospective studies including facet joint injections and discography and eventually MRI have failed to identify patients with a painful segment/disc that will benefit from fusion surgery. Our purpose was to analyse in detail the pre-operative symptoms and signs presented by patients who showed substantial relief from their back pain following spinal fusion surgery with the aim of possibly finding a pain pattern indicating segmental, discogenic pain. We analysed 40 consecutive patients, mean age 41 years, with a history of disabling low back pain for a mean of 7.7 years. Before surgery the patients completed a detailed questionnaire concerning various aspects of their back pain, and findings at clinical examination were thoroughly noted. Monosegmental posterior lumbar interbody fusion without internal fixation was performed using microsurgical technique. Outcome was assessed at 1, 2 and 4 years after surgery and finally at 18 years, using self-reporting measures and assessment by an independent examiner. Assessment at 18 years applied the Balanced Inventory for Spinal Disorders Questionnaire and the Roland-Morris Disability Questionnaire. According to the independent observer's assessment at two years 27 of the 40 patients were much improved. Analysis of the pre-operative depiction of the back symptoms of this group revealed a rather uniform pattern, the most important being: dominating back pain originating in the midline of the spine, with a dull, aching character and stabbing pain in the same area provoked by sudden movements. Most patients in this group also had diffuse pain radiation of various extension down one or both legs and often bladder dysfunction with frequency. At clinical examination, localized interspinal tenderness was observed within the spinal area in question and the patient's back pain was provoked by pressure in that area and by tapping a neighbouring spinous process. At 18 years after surgery 19 patients assessed themselves as much improved. At that time 5 of them had pension due to age, 7 early pension, one worked full time and six patients part time. Eleven patients were re-operated due to defect bony healing. The results may suggest that the use of a detailed symptom analysis and clinical examination may make it possible to select a subgroup of patients within the CLBP group likely to have better outcome following fusion surgery. The next step would be to execute prospective studies and if our findings concerning back pain details and signs among CLPB patients can be confirmed this can provide for more accurate selection of patients suitable for fusion surgery. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  1. Parameters and functional analysis of the deep epaxial muscles in the thoracic, lumbar and sacral regions of the equine spine.

    PubMed

    García Liñeiro, J A; Graziotti, G H; Rodríguez Menéndez, J M; Ríos, C M; Affricano, N O; Victorica, C L

    2018-07-01

    The epaxial muscles produce intervertebral rotation in the transverse, vertical and axial axes. These muscles also counteract the movements induced by gravitational and inertial forces and movements produced by antagonistic muscles and the intrinsic muscles of the pelvic limb. Their fascicles are innervated by the dorsal branch of the spinal nerve, which corresponds to the metamere of its cranial insertion in the spinous process. The structure allows the function of the muscles to be predicted: those with long and parallel fibres have a shortening function, whereas the muscles with short and oblique fibres have an antigravity action. In the horse, the multifidus muscle of the thoracolumbar region extends in multiple segments of two to eight vertebral motion segments (VMS). Functionally, the multifidus muscle is considered a spine stabiliser, maintaining VMS neutrality during spine rotations. However, there is evidence of the structural and functional heterogeneity of the equine thoracolumbar multifidus muscle, depending on the VMS considered, related to the complex control of the required neuromuscular activity. Osteoarticular lesions of the spine have been directly related to asymmetries of the multifidus muscle. The lateral (LDSM) and medial (MDSM) dorsal sacrocaudal muscles may be included in the multifidus complex, the function of which is also unclear in the lumbosacral region. The functional parameters of maximum force (F max ), maximum velocity of contraction (V max ) and joint moment (M) of the multifidus muscles inserted in the 4th, 9th, 12th and 17th thoracic and 3rd and 4th lumbar vertebrae of six horses were studied postmortem (for example: 4MT4 indicates the multifidus muscle that crosses four metameres with cranial insertion in the T4 vertebra). Furthermore, the structural and functional characteristics of LDSM and MDSM were determined. Data were analysed by analysis of variance (anova) in a randomised complete block design (P ≤ 0.05). For some muscles, the ordering of V max values was almost opposite to that of F max values, generally indicating antigravity or dynamic functions, depending on the muscle and VMS. The muscles 3MT12, 3ML3 and 4ML4 exhibited high F max and low V max values, indicating a stabilising action. The very long 7MT4 and 8MT4 multifidus had low F max and high V max values, suggesting a shortening action. However, some functional characteristics of interest did not fall within these general observations, also indicating a dual action. In summary, the results of the analysis of various structural and functional parameters confirm the structural and functional heterogeneity of the equine thoracolumbar multifidus complex, depending on the VMS, regardless of the number of metameres crossing each fascicle. To clarify the functions of the equine multifidus muscle complex, this study aimed to assess its functional parameters in thoracolumbar VMSs with different movement characteristics and in the MDSM and LDSM muscles, hypothesising that the functional parameters vary significantly when the VMS is considered. © 2018 Anatomical Society.

  2. Systems and Methods for Radar Data Communication

    NASA Technical Reports Server (NTRS)

    Bunch, Brian (Inventor); Szeto, Roland (Inventor); Miller, Brad (Inventor)

    2013-01-01

    A radar information processing system is operable to process high bandwidth radar information received from a radar system into low bandwidth radar information that may be communicated to a low bandwidth connection coupled to an electronic flight bag (EFB). An exemplary embodiment receives radar information from a radar system, the radar information communicated from the radar system at a first bandwidth; processes the received radar information into processed radar information, the processed radar information configured for communication over a connection operable at a second bandwidth, the second bandwidth lower than the first bandwidth; and communicates the radar information from a radar system, the radar information communicated from the radar system at a first bandwidth.

  3. Development of the Diagnostic Expert System for Tea Processing

    NASA Astrophysics Data System (ADS)

    Yoshitomi, Hitoshi; Yamaguchi, Yuichi

    A diagnostic expert system for tea processing which can presume the cause of the defect of the processed tea was developed to contribute to the improvement of tea processing. This system that consists of some programs can be used through the Internet. The inference engine, the core of the system adopts production system which is well used on artificial intelligence, and is coded by Prolog as the artificial intelligence oriented language. At present, 176 rules for inference have been registered on this system. The system will be able to presume better if more rules are added to the system.

  4. Process Based on SysML for New Launchers System and Software Developments

    NASA Astrophysics Data System (ADS)

    Hiron, Emmanuel; Miramont, Philippe

    2010-08-01

    The purpose of this paper is to present the Astrium-ST engineering process based on SysML. This process is currently set-up in the frame of common CNES /Astrium-ST R&T studies related to the Ariane 5 electrical system and flight software modelling. The tool used to set up this process is Rhapsody release 7.3 from IBM-Software firm [1]. This process focuses on the system engineering phase dedicated to Software with the objective to generate both System documents (sequential system design and flight control) and Software specifications.

  5. Process control integration requirements for advanced life support systems applicable to manned space missions

    NASA Technical Reports Server (NTRS)

    Spurlock, Paul; Spurlock, Jack M.; Evanich, Peggy L.

    1991-01-01

    An overview of recent developments in process-control technology which might have applications in future advanced life support systems for long-duration space operations is presented. Consideration is given to design criteria related to control system selection and optimization, and process-control interfacing methodology. Attention is also given to current life support system process control strategies, innovative sensors, instrumentation and control, and innovations in process supervision.

  6. Aircraft Alerting Systems Standardization Study. Phase IV. Accident Implications on Systems Design.

    DTIC Science & Technology

    1982-06-01

    computing and processing to assimilate and process status informa- 5 tion using...provided with capabilities in computing and processing , sensing, interfacing, and controlling and displaying. 17 o Computing and Processing - Algorithms...alerting system to perform a flight status monitor function would require additional sensinq, computing and processing , interfacing, and controlling

  7. Passive serialization in a multitasking environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennessey, J.P.; Osisek, D.L.; Seigh, J.W. II

    1989-02-28

    In a multiprocessing system having a control program in which data objects are shared among processes, this patent describes a method for serializing references to a data object by the processes so as to prevent invalid references to the data object by any process when an operation requiring exclusive access is performed by another process, comprising the steps of: permitting the processes to reference data objects on a shared access basis without obtaining a shared lock; monitoring a point of execution of the control program which is common to all processes in the system, which occurs regularly in the process'more » execution and across which no references to any data object can be maintained by any process, except references using locks; establishing a system reference point which occurs after each process in the system has passed the point of execution at least once since the last such system reference point; requesting an operation requiring exclusive access on a selected data object; preventing subsequent references by other processes to the selected data object; waiting until two of the system references points have occurred; and then performing the requested operation.« less

  8. 45 CFR 205.38 - Federal financial participation (FFP) for establishing a statewide mechanized system.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...

  9. 45 CFR 205.38 - Federal financial participation (FFP) for establishing a statewide mechanized system.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...

  10. 45 CFR 205.38 - Federal financial participation (FFP) for establishing a statewide mechanized system.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...

  11. 45 CFR 205.38 - Federal financial participation (FFP) for establishing a statewide mechanized system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...

  12. 45 CFR 205.38 - Federal financial participation (FFP) for establishing a statewide mechanized system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., development or installation of a statewide automated application processing and information retrieval system.... (2) The system is compatible with the claims processing and information retrieval systems used in the... in the title IV-A (AFDC) Automated Application Processing and Information Retrieval System Guide...

  13. Cloud object store for archive storage of high performance computing data using decoupling middleware

    DOEpatents

    Bent, John M.; Faibish, Sorin; Grider, Gary

    2015-06-30

    Cloud object storage is enabled for archived data, such as checkpoints and results, of high performance computing applications using a middleware process. A plurality of archived files, such as checkpoint files and results, generated by a plurality of processes in a parallel computing system are stored by obtaining the plurality of archived files from the parallel computing system; converting the plurality of archived files to objects using a log structured file system middleware process; and providing the objects for storage in a cloud object storage system. The plurality of processes may run, for example, on a plurality of compute nodes. The log structured file system middleware process may be embodied, for example, as a Parallel Log-Structured File System (PLFS). The log structured file system middleware process optionally executes on a burst buffer node.

  14. Polymer Waveguide Fabrication Techniques

    NASA Astrophysics Data System (ADS)

    Ramey, Delvan A.

    1985-01-01

    The ability of integrated optic systems to compete in signal processing aplications with more traditional analog and digital electronic systems is discussed. The Acousto-Optic Spectrum Analyzer is an example which motivated the particular work discussed herein. Provided real time processing is more critical than absolute accuracy, such integrated optic systems fulfill a design need. Fan-out waveguide arrays allow crosstalk in system detector arrays to be controlled without directly limiting system resolution. A polyurethane pattern definition process was developed in order to demonstrate fan-out arrays. This novel process is discussed, along with further research needs. Integrated optic system market penetration would be enhanced by development of commercial processes of this type.

  15. Analysis of Hospital Processes with Process Mining Techniques.

    PubMed

    Orellana García, Arturo; Pérez Alfonso, Damián; Larrea Armenteros, Osvaldo Ulises

    2015-01-01

    Process mining allows for discovery, monitoring, and improving processes identified in information systems from their event logs. In hospital environments, process analysis has been a crucial factor for cost reduction, control and proper use of resources, better patient care, and achieving service excellence. This paper presents a new component for event logs generation in the Hospital Information System or HIS, developed at University of Informatics Sciences. The event logs obtained are used for analysis of hospital processes with process mining techniques. The proposed solution intends to achieve the generation of event logs in the system with high quality. The performed analyses allowed for redefining functions in the system and proposed proper flow of information. The study exposed the need to incorporate process mining techniques in hospital systems to analyze the processes execution. Moreover, we illustrate its application for making clinical and administrative decisions for the management of hospital activities.

  16. Logistics Control Facility: A Normative Model for Total Asset Visibility in the Air Force Logistics System

    DTIC Science & Technology

    1994-09-01

    IIssue Computers, information systems, and communication systems are being increasingly used in transportation, warehousing, order processing , materials...inventory levels, reduced order processing times, reduced order processing costs, and increased customer satisfaction. While purchasing and transportation...process, the speed in which crders are processed would increase significantly. Lowering the order processing time in turn lowers the lead time, which in

  17. Advanced Information Processing System (AIPS) proof-of-concept system functional design I/O network system services

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The function design of the Input/Output (I/O) services for the Advanced Information Processing System (AIPS) proof of concept system is described. The data flow diagrams, which show the functional processes in I/O services and the data that flows among them, are contained. A complete list of the data identified on the data flow diagrams and in the process descriptions are provided.

  18. Reprocessing system with nuclide separation based on chromatography in hydrochloric acid solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Tatsuya; Tachibana, Yu; Koyama, Shi-ichi

    2013-07-01

    We have proposed the reprocessing system with nuclide separation processes based on the chromatographic technique in the hydrochloric acid solution system. Our proposed system consists of the dissolution process, the reprocessing process, the minor actinide separation process, and nuclide separation processes. In the reprocessing and separation processes, the pyridine resin is used as a main separation media. It was confirmed that the dissolution in the hydrochloric acid solution is easily achieved by the plasma voloxidation and by the addition of oxygen peroxide into the hydrochloric acid solution.

  19. A methodology for evaluation of an interactive multispectral image processing system

    NASA Technical Reports Server (NTRS)

    Kovalick, William M.; Newcomer, Jeffrey A.; Wharton, Stephen W.

    1987-01-01

    Because of the considerable cost of an interactive multispectral image processing system, an evaluation of a prospective system should be performed to ascertain if it will be acceptable to the anticipated users. Evaluation of a developmental system indicated that the important system elements include documentation, user friendliness, image processing capabilities, and system services. The criteria and evaluation procedures for these elements are described herein. The following factors contributed to the success of the evaluation of the developmental system: (1) careful review of documentation prior to program development, (2) construction and testing of macromodules representing typical processing scenarios, (3) availability of other image processing systems for referral and verification, and (4) use of testing personnel with an applications perspective and experience with other systems. This evaluation was done in addition to and independently of program testing by the software developers of the system.

  20. Prototype architecture for a VLSI level zero processing system. [Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Shi, Jianfei; Grebowsky, Gerald J.; Horner, Ward P.; Chesney, James R.

    1989-01-01

    The prototype architecture and implementation of a high-speed level zero processing (LZP) system are discussed. Due to the new processing algorithm and VLSI technology, the prototype LZP system features compact size, low cost, high processing throughput, and easy maintainability and increased reliability. Though extensive control functions have been done by hardware, the programmability of processing tasks makes it possible to adapt the system to different data formats and processing requirements. It is noted that the LZP system can handle up to 8 virtual channels and 24 sources with combined data volume of 15 Gbytes per orbit. For greater demands, multiple LZP systems can be configured in parallel, each called a processing channel and assigned a subset of virtual channels. The telemetry data stream will be steered into different processing channels in accordance with their virtual channel IDs. This super system can cope with a virtually unlimited number of virtual channels and sources. In the near future, it is expected that new disk farms with data rate exceeding 150 Mbps will be available from commercial vendors due to the advance in disk drive technology.

  1. Systems Thinking for the Enterprise: A Thought Piece

    NASA Astrophysics Data System (ADS)

    Rebovich, George

    This paper suggests a way of managing the acquisition of capabilities for large-scale government enterprises that is different from traditional "specify and build" approaches commonly employed by U.S. government agencies in acquiring individual systems or systems of systems (SoS). Enterprise capabilities evolve through the emergence and convergence of information and other technologies and their integration into social, institutional and operational organizations and processes. Enterprise capabilities evolve whether or not the enterprise has processes in place to actively manage them. Thus the critical role of enterprise system engineering (ESE) processes should be to shape, enhance and accelerate the "natural" evolution of enterprise capabilities. ESE processes do not replace or add a layer to traditional system engineering (TSE) processes used in developing individual systems or SoS. ESE processes should complement TSE processes by shaping outcome spaces and stimulating interactions among enterprise participants through marketlike mechanisms to reward those that create innovation which moves and accelerates the evolution of the enterprise.

  2. Allostasis and Addiction: Role of the Dopamine and Corticotropin-Releasing Factor Systems

    PubMed Central

    George, Olivier; Le Moal, Michel; Koob, George F.

    2011-01-01

    Allostasis, originally conceptualized to explain persistent morbidity of arousal and autonomic function, is defined as the process of achieving stability through physiological or behavioral change. Two types of biological processes have been proposed to describe the mechanisms underlying allostasis in drug addiction, a within-system adaptation and a between-system adaptation. In the within-system process, the drug elicits an opposing, neutralizing reaction within the same system in which the drug elicits its primary and unconditioned reinforcing actions, while in the between-system process, different neurobiological systems that the one initially activated by the drug are recruited. In this review, we will focus our interest on alterations in the dopaminergic and corticotropin releasing factor systems as within-system and between-system neuroadaptations respectively, that underlie the opponent process to drugs of abuse. We hypothesize that repeated compromised activity in the dopaminergic system and sustained activation of the CRF-CRF1R system with withdrawal episodes may lead to an allostatic load contributing significantly to the transition to drug addiction. PMID:22108506

  3. Recent developments in processing systems for cell and tissue cultures toward therapeutic application.

    PubMed

    Kino-oka, Masahiro; Taya, Masahito

    2009-10-01

    Innovative techniques of cell and tissue processing, based on tissue engineering, have been developed for therapeutic applications. Cell expansion and tissue reconstruction through ex vivo cultures are core processes used to produce engineered tissues with sufficient structural integrity and functionality. In manufacturing, strict management against contamination and human error is compelled due to direct use of un-sterilable products and the laboriousness of culture operations, respectively. Therefore, the development of processing systems for cell and tissue cultures is one of the critical issues for ensuring a stable process and quality of therapeutic products. However, the siting criterion of culture systems to date has not been made clear. This review article classifies some of the known processing systems into 'sealed-chamber' and 'sealed-vessel' culture systems based on the difference in their aseptic spaces, and describes the potential advantages of these systems and current states of culture systems, especially those established by Japanese companies. Moreover, on the basis of the guidelines for isolator systems used in aseptic processing for healthcare products, which are issued by the International Organization for Standardization, the siting criterion of the processing systems for cells and tissue cultures is discussed in perspective of manufacturing therapeutic products in consideration of the regulations according to the Good Manufacturing Practice.

  4. Information processing systems, reasoning modules, and reasoning system design methods

    DOEpatents

    Hohimer, Ryan E.; Greitzer, Frank L.; Hampton, Shawn D.

    2016-08-23

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  5. Information processing systems, reasoning modules, and reasoning system design methods

    DOEpatents

    Hohimer, Ryan E.; Greitzer, Frank L.; Hampton, Shawn D.

    2015-08-18

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  6. Information processing systems, reasoning modules, and reasoning system design methods

    DOEpatents

    Hohimer, Ryan E; Greitzer, Frank L; Hampton, Shawn D

    2014-03-04

    Information processing systems, reasoning modules, and reasoning system design methods are described. According to one aspect, an information processing system includes working memory comprising a semantic graph which comprises a plurality of abstractions, wherein the abstractions individually include an individual which is defined according to an ontology and a reasoning system comprising a plurality of reasoning modules which are configured to process different abstractions of the semantic graph, wherein a first of the reasoning modules is configured to process a plurality of abstractions which include individuals of a first classification type of the ontology and a second of the reasoning modules is configured to process a plurality of abstractions which include individuals of a second classification type of the ontology, wherein the first and second classification types are different.

  7. Social network supported process recommender system.

    PubMed

    Ye, Yanming; Yin, Jianwei; Xu, Yueshen

    2014-01-01

    Process recommendation technologies have gained more and more attention in the field of intelligent business process modeling to assist the process modeling. However, most of the existing technologies only use the process structure analysis and do not take the social features of processes into account, while the process modeling is complex and comprehensive in most situations. This paper studies the feasibility of social network research technologies on process recommendation and builds a social network system of processes based on the features similarities. Then, three process matching degree measurements are presented and the system implementation is discussed subsequently. Finally, experimental evaluations and future works are introduced.

  8. Tailoring Systems Engineering Processes in a Conceptual Design Environment: A Case Study at NASA Marshall Spaceflight Center's ACO

    NASA Technical Reports Server (NTRS)

    Mulqueen, John; Maples, C. Dauphne; Fabisinski, Leo, III

    2012-01-01

    This paper provides an overview of Systems Engineering as it is applied in a conceptual design space systems department at the National Aeronautics and Space Administration (NASA) Marshall Spaceflight Center (MSFC) Advanced Concepts Office (ACO). Engineering work performed in the NASA MFSC's ACO is targeted toward the Exploratory Research and Concepts Development life cycle stages, as defined in the International Council on Systems Engineering (INCOSE) System Engineering Handbook. This paper addresses three ACO Systems Engineering tools that correspond to three INCOSE Technical Processes: Stakeholder Requirements Definition, Requirements Analysis, and Integration, as well as one Project Process Risk Management. These processes are used to facilitate, streamline, and manage systems engineering processes tailored for the earliest two life cycle stages, which is the environment in which ACO engineers work. The role of systems engineers and systems engineering as performed in ACO is explored in this paper. The need for tailoring Systems Engineering processes, tools, and products in the ever-changing engineering services ACO provides to its customers is addressed.

  9. Microphone Array Phased Processing System (MAPPS): Version 4.0 Manual

    NASA Technical Reports Server (NTRS)

    Watts, Michael E.; Mosher, Marianne; Barnes, Michael; Bardina, Jorge

    1999-01-01

    A processing system has been developed to meet increasing demands for detailed noise measurement of individual model components. The Microphone Array Phased Processing System (MAPPS) uses graphical user interfaces to control all aspects of data processing and visualization. The system uses networked parallel computers to provide noise maps at selected frequencies in a near real-time testing environment. The system has been successfully used in the NASA Ames 7- by 10-Foot Wind Tunnel.

  10. A conceptual persistent healthcare quality improvement process for software development management.

    PubMed

    Lin, Jen-Chiun; Su, Mei-Ju; Cheng, Po-Hsun; Weng, Yung-Chien; Chen, Sao-Jie; Lai, Jin-Shin; Lai, Feipei

    2007-01-01

    This paper illustrates a sustained conceptual service quality improvement process for the management of software development within a healthcare enterprise. Our proposed process is revised from Niland's healthcare quality information system (HQIS). This process includes functions to survey the satisfaction of system functions, describe the operation bylaws on-line, and provide on-demand training. To achieve these goals, we integrate five information systems in National Taiwan University Hospital, including healthcare information systems, health quality information system, requirement management system, executive information system, and digital learning system, to form a full Deming cycle. A preliminary user satisfaction survey showed that our outpatient information system scored an average of 71.31 in 2006.

  11. AVIRIS ground data-processing system

    NASA Technical Reports Server (NTRS)

    Reimer, John H.; Heyada, Jan R.; Carpenter, Steve C.; Deich, William T. S.; Lee, Meemong

    1987-01-01

    The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) has been under development at JPL for the past four years. During this time, a dedicated ground data-processing system has been designed and implemented to store and process the large amounts of data expected. This paper reviews the objectives of this ground data-processing system and describes the hardware. An outline of the data flow through the system is given, and the software and incorporated algorithms developed specifically for the systematic processing of AVIRIS data are described.

  12. Long-term care information systems: an overview of the selection process.

    PubMed

    Nahm, Eun-Shim; Mills, Mary Etta; Feege, Barbara

    2006-06-01

    Under the current Medicare Prospective Payment System method and the ever-changing managed care environment, the long-term care information system is vital to providing quality care and to surviving in business. system selection process should be an interdisciplinary effort involving all necessary stakeholders for the proposed system. The system selection process can be modeled following the Systems Developmental Life Cycle: identifying problems, opportunities, and objectives; determining information requirements; analyzing system needs; designing the recommended system; and developing and documenting software.

  13. Industrial process system assessment: bridging process engineering and life cycle assessment through multiscale modeling.

    EPA Science Inventory

    The Industrial Process System Assessment (IPSA) methodology is a multiple step allocation approach for connecting information from the production line level up to the facility level and vice versa using a multiscale model of process systems. The allocation procedure assigns inpu...

  14. APPLEPIPS /Apple Personal Image Processing System/ - An interactive digital image processing system for the Apple II microcomputer

    NASA Technical Reports Server (NTRS)

    Masuoka, E.; Rose, J.; Quattromani, M.

    1981-01-01

    Recent developments related to microprocessor-based personal computers have made low-cost digital image processing systems a reality. Image analysis systems built around these microcomputers provide color image displays for images as large as 256 by 240 pixels in sixteen colors. Descriptive statistics can be computed for portions of an image, and supervised image classification can be obtained. The systems support Basic, Fortran, Pascal, and assembler language. A description is provided of a system which is representative of the new microprocessor-based image processing systems currently on the market. While small systems may never be truly independent of larger mainframes, because they lack 9-track tape drives, the independent processing power of the microcomputers will help alleviate some of the turn-around time problems associated with image analysis and display on the larger multiuser systems.

  15. System-Level Shared Governance Structures and Processes in Healthcare Systems With Magnet®-Designated Hospitals: A Descriptive Study.

    PubMed

    Underwood, Carlisa M; Hayne, Arlene N

    The purpose was to identify and describe structures and processes of best practices for system-level shared governance in healthcare systems. Currently, more than 64.6% of US community hospitals are part of a system. System chief nurse executives (SCNEs) are challenged to establish leadership structures and processes that effectively and efficiently disseminate best practices for patients and staff across complex organizations, geographically dispersed locations, and populations. Eleven US healthcare SCNEs from the American Nurses Credentialing Center's repository of Magnet®-designated facilities participated in a 35-multiquestion interview based on Kanter's Theory of Organizational Empowerment. Most SCNEs reported the presence of more than 50% of the empowerment structures and processes in system-level shared governance. Despite the difficulties and complexities of growing health systems, SCNEs have replicated empowerment characteristics of hospital shared governance structures and processes at the system level.

  16. Engineering Supply Management System: The Next Generation

    DTIC Science & Technology

    1991-09-01

    010 Partia! receipts 0018 Automatic inventory update 0 048 Discrepant material 0 004 Order processing requirements Transaction reversal capability 0 012...August 1991. 2-5 sys.em’s modules that support the DEH’s needs are the Sales Order Processing , Register Sales, Purchase Order Processing , Inventory...modular system developed by PIC Business Systems, Incorporated. This system possesses Order Processing , Inventory Management, Purchase Orders, and

  17. Event Processing and Variable Part of Sample Period Determining in Combined Systems Using GA

    NASA Astrophysics Data System (ADS)

    Strémy, Maximilián; Závacký, Pavol; Jedlička, Martin

    2011-01-01

    This article deals with combined dynamic systems and usage of modern techniques in dealing with these systems, focusing particularly on sampling period design, cyclic processing tasks and related processing algorithms in the combined event management systems using genetic algorithms.

  18. 42 CFR 431.832 - Reporting requirements for claims processing assessment systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... assessment systems. 431.832 Section 431.832 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES... GENERAL ADMINISTRATION Quality Control Medicaid Quality Control (mqc) Claims Processing Assessment System § 431.832 Reporting requirements for claims processing assessment systems. (a) The agency must submit...

  19. System safety management lessons learned from the US Army acquisition process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piatt, J.A.

    1989-05-01

    The Assistant Secretary of the Army for Research, Development and Acquisition directed the Army Safety Center to provide an audit of the causes of accidents and safety of use restrictions on recently fielded systems by tracking residual hazards back through the acquisition process. The objective was to develop lessons learned'' that could be applied to the acquisition process to minimize mishaps in fielded systems. System safety management lessons learned are defined as Army practices or policies, derived from past successes and failures, that are expected to be effective in eliminating or reducing specific systemic causes of residual hazards. They aremore » broadly applicable and supportive of the Army structure and acquisition objectives. Pacific Northwest Laboratory (PNL) was given the task of conducting an independent, objective appraisal of the Army's system safety program in the context of the Army materiel acquisition process by focusing on four fielded systems which are products of that process. These systems included the Apache helicopter, the Bradley Fighting Vehicle (BFV), the Tube Launched, Optically Tracked, Wire Guided (TOW) Missile and the High Mobility Multipurpose Wheeled Vehicle (HMMWV). The objective of this study was to develop system safety management lessons learned associated with the acquisition process. The first step was to identify residual hazards associated with the selected systems. Since it was impossible to track all residual hazards through the acquisition process, certain well-known, high visibility hazards were selected for detailed tracking. These residual hazards illustrate a variety of systemic problems. Systemic or process causes were identified for each residual hazard and analyzed to determine why they exist. System safety management lessons learned were developed to address related systemic causal factors. 29 refs., 5 figs.« less

  20. Hadoop-based implementation of processing medical diagnostic records for visual patient system

    NASA Astrophysics Data System (ADS)

    Yang, Yuanyuan; Shi, Liehang; Xie, Zhe; Zhang, Jianguo

    2018-03-01

    We have innovatively introduced Visual Patient (VP) concept and method visually to represent and index patient imaging diagnostic records (IDR) in last year SPIE Medical Imaging (SPIE MI 2017), which can enable a doctor to review a large amount of IDR of a patient in a limited appointed time slot. In this presentation, we presented a new approach to design data processing architecture of VP system (VPS) to acquire, process and store various kinds of IDR to build VP instance for each patient in hospital environment based on Hadoop distributed processing structure. We designed this system architecture called Medical Information Processing System (MIPS) with a combination of Hadoop batch processing architecture and Storm stream processing architecture. The MIPS implemented parallel processing of various kinds of clinical data with high efficiency, which come from disparate hospital information system such as PACS, RIS LIS and HIS.

  1. Modeling Business Processes in Public Administration

    NASA Astrophysics Data System (ADS)

    Repa, Vaclav

    During more than 10 years of its existence business process modeling became a regular part of organization management practice. It is mostly regarded. as a part of information system development or even as a way to implement some supporting technology (for instance workflow system). Although I do not agree with such reduction of the real meaning of a business process, it is necessary to admit that information technologies play an essential role in business processes (see [1] for more information), Consequently, an information system is inseparable from a business process itself because it is a cornerstone of the general basic infrastructure of a business. This fact impacts on all dimensions of business process management. One of these dimensions is the methodology that postulates that the information systems development provide the business process management with exact methods and tools for modeling business processes. Also the methodology underlying the approach presented in this paper has its roots in the information systems development methodology.

  2. An open system approach to process reengineering in a healthcare operational environment.

    PubMed

    Czuchry, A J; Yasin, M M; Norris, J

    2000-01-01

    The objective of this study is to examine the applicability of process reengineering in a healthcare operational environment. The intake process of a mental healthcare service delivery system is analyzed systematically to identify process-related problems. A methodology which utilizes an open system orientation coupled with process reengineering is utilized to overcome operational and patient related problems associated with the pre-reengineered intake process. The systematic redesign of the intake process resulted in performance improvements in terms of cost, quality, service and timing.

  3. Managing Analysis Models in the Design Process

    NASA Technical Reports Server (NTRS)

    Briggs, Clark

    2006-01-01

    Design of large, complex space systems depends on significant model-based support for exploration of the design space. Integrated models predict system performance in mission-relevant terms given design descriptions and multiple physics-based numerical models. Both the design activities and the modeling activities warrant explicit process definitions and active process management to protect the project from excessive risk. Software and systems engineering processes have been formalized and similar formal process activities are under development for design engineering and integrated modeling. JPL is establishing a modeling process to define development and application of such system-level models.

  4. Evolution of the archaeal and mammalian information processing systems: towards an archaeal model for human disease.

    PubMed

    Lyu, Zhe; Whitman, William B

    2017-01-01

    Current evolutionary models suggest that Eukaryotes originated from within Archaea instead of being a sister lineage. To test this model of ancient evolution, we review recent studies and compare the three major information processing subsystems of replication, transcription and translation in the Archaea and Eukaryotes. Our hypothesis is that if the Eukaryotes arose within the archaeal radiation, their information processing systems will appear to be one of kind and not wholly original. Within the Eukaryotes, the mammalian or human systems are emphasized because of their importance in understanding health. Biochemical as well as genetic studies provide strong evidence for the functional similarity of archaeal homologs to the mammalian information processing system and their dissimilarity to the bacterial systems. In many independent instances, a simple archaeal system is functionally equivalent to more elaborate eukaryotic homologs, suggesting that evolution of complexity is likely an central feature of the eukaryotic information processing system. Because fewer components are often involved, biochemical characterizations of the archaeal systems are often easier to interpret. Similarly, the archaeal cell provides a genetically and metabolically simpler background, enabling convenient studies on the complex information processing system. Therefore, Archaea could serve as a parsimonious and tractable host for studying human diseases that arise in the information processing systems.

  5. The analysis of magnesium oxide hydration in three-phase reaction system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, Xiaojia; Guo, Lin; Chen, Chen

    In order to investigate the magnesium oxide hydration process in gas–liquid–solid (three-phase) reaction system, magnesium hydroxide was prepared by magnesium oxide hydration in liquid–solid (two-phase) and three-phase reaction systems. A semi-empirical model and the classical shrinking core model were used to fit the experimental data. The fitting result shows that both models describe well the hydration process of three-phase system, while only the semi-empirical model right for the hydration process of two-phase system. The characterization of the hydration product using X-Ray diffraction (XRD) and scanning electron microscope (SEM) was performed. The XRD and SEM show hydration process in the two-phasemore » system follows common dissolution/precipitation mechanism. While in the three-phase system, the hydration process undergo MgO dissolution, Mg(OH){sub 2} precipitation, Mg(OH){sub 2} peeling off from MgO particle and leaving behind fresh MgO surface. - Graphical abstract: There was existence of a peeling-off process in the gas–liquid–solid (three-phase) MgO hydration system. - Highlights: • Magnesium oxide hydration in gas–liquid–solid system was investigated. • The experimental data in three-phase system could be fitted well by two models. • The morphology analysis suggested that there was existence of a peel-off process.« less

  6. Proposed Framework for the Evaluation of Standalone Corpora Processing Systems: An Application to Arabic Corpora

    PubMed Central

    Al-Thubaity, Abdulmohsen; Alqifari, Reem

    2014-01-01

    Despite the accessibility of numerous online corpora, students and researchers engaged in the fields of Natural Language Processing (NLP), corpus linguistics, and language learning and teaching may encounter situations in which they need to develop their own corpora. Several commercial and free standalone corpora processing systems are available to process such corpora. In this study, we first propose a framework for the evaluation of standalone corpora processing systems and then use it to evaluate seven freely available systems. The proposed framework considers the usability, functionality, and performance of the evaluated systems while taking into consideration their suitability for Arabic corpora. While the results show that most of the evaluated systems exhibited comparable usability scores, the scores for functionality and performance were substantially different with respect to support for the Arabic language and N-grams profile generation. The results of our evaluation will help potential users of the evaluated systems to choose the system that best meets their needs. More importantly, the results will help the developers of the evaluated systems to enhance their systems and developers of new corpora processing systems by providing them with a reference framework. PMID:25610910

  7. Proposed framework for the evaluation of standalone corpora processing systems: an application to Arabic corpora.

    PubMed

    Al-Thubaity, Abdulmohsen; Al-Khalifa, Hend; Alqifari, Reem; Almazrua, Manal

    2014-01-01

    Despite the accessibility of numerous online corpora, students and researchers engaged in the fields of Natural Language Processing (NLP), corpus linguistics, and language learning and teaching may encounter situations in which they need to develop their own corpora. Several commercial and free standalone corpora processing systems are available to process such corpora. In this study, we first propose a framework for the evaluation of standalone corpora processing systems and then use it to evaluate seven freely available systems. The proposed framework considers the usability, functionality, and performance of the evaluated systems while taking into consideration their suitability for Arabic corpora. While the results show that most of the evaluated systems exhibited comparable usability scores, the scores for functionality and performance were substantially different with respect to support for the Arabic language and N-grams profile generation. The results of our evaluation will help potential users of the evaluated systems to choose the system that best meets their needs. More importantly, the results will help the developers of the evaluated systems to enhance their systems and developers of new corpora processing systems by providing them with a reference framework.

  8. Deployment of ERP Systems at Automotive Industries, Security Inspection (Case Study: IRAN KHODRO Automotive Company)

    NASA Astrophysics Data System (ADS)

    Ali, Hatamirad; Hasan, Mehrjerdi

    Automotive industry and car production process is one of the most complex and large-scale production processes. Today, information technology (IT) and ERP systems incorporates a large portion of production processes. Without any integrated systems such as ERP, the production and supply chain processes will be tangled. The ERP systems, that are last generation of MRP systems, make produce and sale processes of these industries easier and this is the major factor of development of these industries anyhow. Today many of large-scale companies are developing and deploying the ERP systems. The ERP systems facilitate many of organization processes and make organization to increase efficiency. The security is a very important part of the ERP strategy at the organization, Security at the ERP systems, because of integrity and extensive, is more important of local and legacy systems. Disregarding of this point can play a giant role at success or failure of this kind of systems. The IRANKHODRO is the biggest automotive factory in the Middle East with an annual production over 600.000 cars. This paper presents ERP security deployment experience at the "IRANKHODRO Company". Recently, by launching ERP systems, it moved a big step toward more developments.

  9. Power processing systems for ion thrusters.

    NASA Technical Reports Server (NTRS)

    Herron, B. G.; Garth, D. R.; Finke, R. C.; Shumaker, H. A.

    1972-01-01

    The proposed use of ion thrusters to fulfill various communication satellite propulsion functions such as east-west and north-south stationkeeping, attitude control, station relocation and orbit raising, naturally leads to the requirement for lightweight, efficient and reliable thruster power processing systems. Collectively, the propulsion requirements dictate a wide range of thruster power levels and operational lifetimes, which must be matched by the power processing. This paper will discuss the status of such power processing systems, present system design alternatives and project expected near future power system performance.

  10. Selective catalytic reduction system and process using a pre-sulfated zirconia binder

    DOEpatents

    Sobolevskiy, Anatoly; Rossin, Joseph A.

    2010-06-29

    A selective catalytic reduction (SCR) process with a palladium catalyst for reducing NOx in a gas, using hydrogen as a reducing agent is provided. The process comprises contacting the gas stream with a catalyst system, the catalyst system comprising (ZrO.sub.2)SO.sub.4, palladium, and a pre-sulfated zirconia binder. The inclusion of a pre-sulfated zirconia binder substantially increases the durability of a Pd-based SCR catalyst system. A system for implementing the disclosed process is further provided.

  11. The application of intelligent process control to space based systems

    NASA Technical Reports Server (NTRS)

    Wakefield, G. Steve

    1990-01-01

    The application of Artificial Intelligence to electronic and process control can help attain the autonomy and safety requirements of manned space systems. An overview of documented applications within various industries is presented. The development process is discussed along with associated issues for implementing an intelligence process control system.

  12. Potential of Laboratory Execution Systems (LESs) to Simplify the Application of Business Process Management Systems (BPMSs) in Laboratory Automation.

    PubMed

    Neubert, Sebastian; Göde, Bernd; Gu, Xiangyu; Stoll, Norbert; Thurow, Kerstin

    2017-04-01

    Modern business process management (BPM) is increasingly interesting for laboratory automation. End-to-end workflow automation and improved top-level systems integration for information technology (IT) and automation systems are especially prominent objectives. With the ISO Standard Business Process Model and Notation (BPMN) 2.X, a system-independent and interdisciplinary accepted graphical process control notation is provided, allowing process analysis, while also being executable. The transfer of BPM solutions to structured laboratory automation places novel demands, for example, concerning the real-time-critical process and systems integration. The article discusses the potential of laboratory execution systems (LESs) for an easier implementation of the business process management system (BPMS) in hierarchical laboratory automation. In particular, complex application scenarios, including long process chains based on, for example, several distributed automation islands and mobile laboratory robots for a material transport, are difficult to handle in BPMSs. The presented approach deals with the displacement of workflow control tasks into life science specialized LESs, the reduction of numerous different interfaces between BPMSs and subsystems, and the simplification of complex process modelings. Thus, the integration effort for complex laboratory workflows can be significantly reduced for strictly structured automation solutions. An example application, consisting of a mixture of manual and automated subprocesses, is demonstrated by the presented BPMS-LES approach.

  13. Selected Systems Engineering Process Deficiencies and Their Consequences

    NASA Technical Reports Server (NTRS)

    Thomas, Lawrence Dale

    2006-01-01

    The systems engineering process is well established and well understood. While this statement could be argued in the light of the many systems engineering guidelines and that have been developed, comparative review of these respective descriptions reveal that they differ primarily in the number of discrete steps or other nuances, and are at their core essentially common. Likewise, the systems engineering textbooks differ primarily in the context for application of systems engineering or in the utilization of evolved tools and techniques, not in the basic method. Thus, failures in systems engineering cannot credibly be attributed to implementation of the wrong systems engineering process among alternatives. However, numerous systems failures can be attributed to deficient implementation of the systems engineering process. What may clearly be perceived as a system engineering deficiency in retrospect can appear to be a well considered system engineering efficiency in real time - an efficiency taken to reduce cost or meet a schedule, or more often both. Typically these efficiencies are grounded on apparently solid rationale, such as reuse of heritage hardware or software. Over time, unintended consequences of a systems engineering process deficiency may begin to be realized, and unfortunately often the consequence is system failure. This paper describes several actual cases of system failures that resulted from deficiencies in their systems engineering process implementation, including the Ariane 5 and the Hubble Space Telescope.

  14. Selected systems engineering process deficiencies and their consequences

    NASA Astrophysics Data System (ADS)

    Thomas, L. Dale

    2007-06-01

    The systems engineering process is well established and well understood. While this statement could be argued in the light of the many systems engineering guidelines and that have been developed, comparative review of these respective descriptions reveal that they differ primarily in the number of discrete steps or other nuances, and are at their core essentially common. Likewise, the systems engineering textbooks differ primarily in the context for application of systems engineering or in the utilization of evolved tools and techniques, not in the basic method. Thus, failures in systems engineering cannot credibly be attributed to implementation of the wrong systems engineering process among alternatives. However, numerous system failures can be attributed to deficient implementation of the systems engineering process. What may clearly be perceived as a systems engineering deficiency in retrospect can appear to be a well considered system engineering efficiency in real time—an efficiency taken to reduce cost or meet a schedule, or more often both. Typically these efficiencies are grounded on apparently solid rationale, such as reuse of heritage hardware or software. Over time, unintended consequences of a systems engineering process deficiency may begin to be realized, and unfortunately often the consequence is systems failure. This paper describes several actual cases of system failures that resulted from deficiencies in their systems engineering process implementation, including the Ariane 5 and the Hubble Space Telescope.

  15. Water recovery and solid waste processing for aerospace and domestic applications. Volume 1: Final report

    NASA Technical Reports Server (NTRS)

    Murray, R. W.

    1973-01-01

    A comprehensive study of advanced water recovery and solid waste processing techniques employed in both aerospace and domestic or commercial applications is reported. A systems approach was used to synthesize a prototype system design of an advanced water treatment/waste processing system. Household water use characteristics were studied and modified through the use of low water use devices and a limited amount of water reuse. This modified household system was then used as a baseline system for development of several water treatment waste processing systems employing advanced techniques. A hybrid of these systems was next developed and a preliminary design was generated to define system and hardware functions.

  16. Is clinical cognition binary or continuous?

    PubMed

    Norman, Geoffrey; Monteiro, Sandra; Sherbino, Jonathan

    2013-08-01

    A dominant theory of clinical reasoning is the so-called "dual processing theory," in which the diagnostic process may proceed through a rapid, unconscious, intuitive process (System 1) or a slow, conceptual, analytical process (System 2). Diagnostic errors are thought to arise primarily from cognitive biases originating in System 1. In this issue, Custers points out that this model is unnecessarily restrictive and that it is more likely that diagnostic tasks may proceed through a variety of mental strategies ranging from "analytical" to "intuitive."The authors of this commentary agree that the notion that System 1 and System 2 processes are somehow in competition and will necessarily lead to different conclusions is unnecessarily restrictive. On the other hand, they argue that there is substantial evidence in support of a dual processing model, and that most objections to dual processing theory can be easily accommodated by simply presuming that both processes operate in concertand that solving any task may rely to varying degrees on both processes.

  17. Social Network Supported Process Recommender System

    PubMed Central

    Ye, Yanming; Yin, Jianwei; Xu, Yueshen

    2014-01-01

    Process recommendation technologies have gained more and more attention in the field of intelligent business process modeling to assist the process modeling. However, most of the existing technologies only use the process structure analysis and do not take the social features of processes into account, while the process modeling is complex and comprehensive in most situations. This paper studies the feasibility of social network research technologies on process recommendation and builds a social network system of processes based on the features similarities. Then, three process matching degree measurements are presented and the system implementation is discussed subsequently. Finally, experimental evaluations and future works are introduced. PMID:24672309

  18. Analyses of requirements for computer control and data processing experiment subsystems. Volume 2: ATM experiment S-056 image data processing system software development

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The IDAPS (Image Data Processing System) is a user-oriented, computer-based, language and control system, which provides a framework or standard for implementing image data processing applications, simplifies set-up of image processing runs so that the system may be used without a working knowledge of computer programming or operation, streamlines operation of the image processing facility, and allows multiple applications to be run in sequence without operator interaction. The control system loads the operators, interprets the input, constructs the necessary parameters for each application, and cells the application. The overlay feature of the IBSYS loader (IBLDR) provides the means of running multiple operators which would otherwise overflow core storage.

  19. Single-chip microcomputer for image processing in the photonic measuring system

    NASA Astrophysics Data System (ADS)

    Smoleva, Olga S.; Ljul, Natalia Y.

    2002-04-01

    The non-contact measuring system has been designed for rail- track parameters control on the Moscow Metro. It detects some significant parameters: rail-track width, rail-track height, gage, rail-slums, crosslevel, pickets, and car speed. The system consists of three subsystems: non-contact system of rail-track width, height, and gage inspection, non-contact system of rail-slums inspection and subsystem for crosslevel, speed, and pickets detection. Data from subsystems is transferred to pre-processing unit. In order to process data received from subsystems, the single-chip signal processor ADSP-2185 must be used due to providing required processing speed. After data will be processed, it is send to PC, which processes it and outputs it in the readable form.

  20. Applied digital signal processing systems for vortex flowmeter with digital signal processing.

    PubMed

    Xu, Ke-Jun; Zhu, Zhi-Hai; Zhou, Yang; Wang, Xiao-Fen; Liu, San-Shan; Huang, Yun-Zhi; Chen, Zhi-Yuan

    2009-02-01

    The spectral analysis is combined with digital filter to process the vortex sensor signal for reducing the effect of disturbance at low frequency from pipe vibrations and increasing the turndown ratio. Using digital signal processing chip, two kinds of digital signal processing systems are developed to implement these algorithms. One is an integrative system, and the other is a separated system. A limiting amplifier is designed in the input analog condition circuit to adapt large amplitude variation of sensor signal. Some technique measures are taken to improve the accuracy of the output pulse, speed up the response time of the meter, and reduce the fluctuation of the output signal. The experimental results demonstrate the validity of the digital signal processing systems.

  1. Annual Symposium on Machine Processing of Remotely Sensed Data, 4th, Purdue University, West Lafayette, Ind., June 21-23, 1977, Proceedings

    NASA Technical Reports Server (NTRS)

    Morrison, D. B. (Editor); Scherer, D. J.

    1977-01-01

    Papers are presented on a variety of techniques for the machine processing of remotely sensed data. Consideration is given to preprocessing methods such as the correction of Landsat data for the effects of haze, sun angle, and reflectance and to the maximum likelihood estimation of signature transformation algorithm. Several applications of machine processing to agriculture are identified. Various types of processing systems are discussed such as ground-data processing/support systems for sensor systems and the transfer of remotely sensed data to operational systems. The application of machine processing to hydrology, geology, and land-use mapping is outlined. Data analysis is considered with reference to several types of classification methods and systems.

  2. Applying a Qualitative Modeling Shell to Process Diagnosis: The Caster System.

    DTIC Science & Technology

    1986-03-01

    Process Diagnosis: The Caster System by Timothy F. Thompson and William J. Clancey Department of Computer Science Stanford University Stanford, CA 94303...MODELING SHELL TO PROCESS DIAGNOSIS: THE CASTER SYSTEM 12 PERSONAL AUTHOR(S) TIMOTHY F. THOMPSON. WESTINGHOUSE R&D CENTER, WILLIAM CLANCEY, STANFORD...editions are obsolete. Applying a Qualitative Modeling Shell to Process Diagnosis: The Caster System by Timothy F. Thompson, Westinghouse R&D Center

  3. Spitzer Telemetry Processing System

    NASA Technical Reports Server (NTRS)

    Stanboli, Alice; Martinez, Elmain M.; McAuley, James M.

    2013-01-01

    The Spitzer Telemetry Processing System (SirtfTlmProc) was designed to address objectives of JPL's Multi-mission Image Processing Lab (MIPL) in processing spacecraft telemetry and distributing the resulting data to the science community. To minimize costs and maximize operability, the software design focused on automated error recovery, performance, and information management. The system processes telemetry from the Spitzer spacecraft and delivers Level 0 products to the Spitzer Science Center. SirtfTlmProc is a unique system with automated error notification and recovery, with a real-time continuous service that can go quiescent after periods of inactivity. The software can process 2 GB of telemetry and deliver Level 0 science products to the end user in four hours. It provides analysis tools so the operator can manage the system and troubleshoot problems. It automates telemetry processing in order to reduce staffing costs.

  4. Design of signal reception and processing system of embedded ultrasonic endoscope

    NASA Astrophysics Data System (ADS)

    Li, Ming; Yu, Feng; Zhang, Ruiqiang; Li, Yan; Chen, Xiaodong; Yu, Daoyin

    2009-11-01

    Embedded Ultrasonic Endoscope, based on embedded microprocessor and embedded real-time operating system, sends a micro ultrasonic probe into coelom through the biopsy channel of the Electronic Endoscope to get the fault histology features of digestive organs by rotary scanning, and acquires the pictures of the alimentary canal mucosal surface. At the same time, ultrasonic signals are processed by signal reception and processing system, forming images of the full histology of the digestive organs. Signal Reception and Processing System is an important component of Embedded Ultrasonic Endoscope. However, the traditional design, using multi-level amplifiers and special digital processing circuits to implement signal reception and processing, is no longer satisfying the standards of high-performance, miniaturization and low power requirements that embedded system requires, and as a result of the high noise that multi-level amplifier brought, the extraction of small signal becomes hard. Therefore, this paper presents a method of signal reception and processing based on double variable gain amplifier and FPGA, increasing the flexibility and dynamic range of the Signal Reception and Processing System, improving system noise level, and reducing power consumption. Finally, we set up the embedded experiment system, using a transducer with the center frequency of 8MHz to scan membrane samples, and display the image of ultrasonic echo reflected by each layer of membrane, with a frame rate of 5Hz, verifying the correctness of the system.

  5. A Systems Approach to Nitrogen Delivery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goins, Bobby

    A systems based approach will be used to evaluate the nitrogen delivery process. This approach involves principles found in Lean, Reliability, Systems Thinking, and Requirements. This unique combination of principles and thought process yields a very in depth look into the system to which it is applied. By applying a systems based approach to the nitrogen delivery process there should be improvements in cycle time, efficiency, and a reduction in the required number of personnel needed to sustain the delivery process. This will in turn reduce the amount of demurrage charges that the site incurs. In addition there should bemore » less frustration associated with the delivery process.« less

  6. Application of agent-based system for bioprocess description and process improvement.

    PubMed

    Gao, Ying; Kipling, Katie; Glassey, Jarka; Willis, Mark; Montague, Gary; Zhou, Yuhong; Titchener-Hooker, Nigel J

    2010-01-01

    Modeling plays an important role in bioprocess development for design and scale-up. Predictive models can also be used in biopharmaceutical manufacturing to assist decision-making either to maintain process consistency or to identify optimal operating conditions. To predict the whole bioprocess performance, the strong interactions present in a processing sequence must be adequately modeled. Traditionally, bioprocess modeling considers process units separately, which makes it difficult to capture the interactions between units. In this work, a systematic framework is developed to analyze the bioprocesses based on a whole process understanding and considering the interactions between process operations. An agent-based approach is adopted to provide a flexible infrastructure for the necessary integration of process models. This enables the prediction of overall process behavior, which can then be applied during process development or once manufacturing has commenced, in both cases leading to the capacity for fast evaluation of process improvement options. The multi-agent system comprises a process knowledge base, process models, and a group of functional agents. In this system, agent components co-operate with each other in performing their tasks. These include the description of the whole process behavior, evaluating process operating conditions, monitoring of the operating processes, predicting critical process performance, and providing guidance to decision-making when coping with process deviations. During process development, the system can be used to evaluate the design space for process operation. During manufacture, the system can be applied to identify abnormal process operation events and then to provide suggestions as to how best to cope with the deviations. In all cases, the function of the system is to ensure an efficient manufacturing process. The implementation of the agent-based approach is illustrated via selected application scenarios, which demonstrate how such a framework may enable the better integration of process operations by providing a plant-wide process description to facilitate process improvement. Copyright 2009 American Institute of Chemical Engineers

  7. Real-time monitoring of clinical processes using complex event processing and transition systems.

    PubMed

    Meinecke, Sebastian

    2014-01-01

    Dependencies between tasks in clinical processes are often complex and error-prone. Our aim is to describe a new approach for the automatic derivation of clinical events identified via the behaviour of IT systems using Complex Event Processing. Furthermore we map these events on transition systems to monitor crucial clinical processes in real-time for preventing and detecting erroneous situations.

  8. 42 CFR 433.116 - FFP for operation of mechanized claims processing and information retrieval systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... and information retrieval systems. 433.116 Section 433.116 Public Health CENTERS FOR MEDICARE... FISCAL ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.116 FFP for operation of mechanized claims processing and information retrieval systems. (a) Subject to paragraph (j) of...

  9. 42 CFR 433.116 - FFP for operation of mechanized claims processing and information retrieval systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... and information retrieval systems. 433.116 Section 433.116 Public Health CENTERS FOR MEDICARE... FISCAL ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.116 FFP for operation of mechanized claims processing and information retrieval systems. (a) Subject to paragraph (j) of...

  10. 42 CFR 433.116 - FFP for operation of mechanized claims processing and information retrieval systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... and information retrieval systems. 433.116 Section 433.116 Public Health CENTERS FOR MEDICARE... FISCAL ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.116 FFP for operation of mechanized claims processing and information retrieval systems. (a) Subject to paragraph (j) of...

  11. 42 CFR 433.116 - FFP for operation of mechanized claims processing and information retrieval systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... and information retrieval systems. 433.116 Section 433.116 Public Health CENTERS FOR MEDICARE... FISCAL ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.116 FFP for operation of mechanized claims processing and information retrieval systems. (a) Subject to paragraph (j) of...

  12. 42 CFR 431.836 - Corrective action under the MQC claims processing assessment system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... assessment system. 431.836 Section 431.836 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT... ADMINISTRATION Quality Control Medicaid Quality Control (mqc) Claims Processing Assessment System § 431.836 Corrective action under the MQC claims processing assessment system. The agency must— (a) Take action to...

  13. A Low Cost Microcomputer System for Process Dynamics and Control Simulations.

    ERIC Educational Resources Information Center

    Crowl, D. A.; Durisin, M. J.

    1983-01-01

    Discusses a video simulator microcomputer system used to provide real-time demonstrations to strengthen students' understanding of process dynamics and control. Also discusses hardware/software and simulations developed using the system. The four simulations model various configurations of a process liquid level tank system. (JN)

  14. NTP comparison process

    NASA Technical Reports Server (NTRS)

    Corban, Robert

    1993-01-01

    The systems engineering process for the concept definition phase of the program involves requirements definition, system definition, and consistent concept definition. The requirements definition process involves obtaining a complete understanding of the system requirements based on customer needs, mission scenarios, and nuclear thermal propulsion (NTP) operating characteristics. A system functional analysis is performed to provide a comprehensive traceability and verification of top-level requirements down to detailed system specifications and provides significant insight into the measures of system effectiveness to be utilized in system evaluation. The second key element in the process is the definition of system concepts to meet the requirements. This part of the process involves engine system and reactor contractor teams to develop alternative NTP system concepts that can be evaluated against specific attributes, as well as a reference configuration against which to compare system benefits and merits. Quality function deployment (QFD), as an excellent tool within Total Quality Management (TQM) techniques, can provide the required structure and provide a link to the voice of the customer in establishing critical system qualities and their relationships. The third element of the process is the consistent performance comparison. The comparison process involves validating developed concept data and quantifying system merits through analysis, computer modeling, simulation, and rapid prototyping of the proposed high risk NTP subsystems. The maximum amount possible of quantitative data will be developed and/or validated to be utilized in the QFD evaluation matrix. If upon evaluation of a new concept or its associated subsystems determine to have substantial merit, those features will be incorporated into the reference configuration for subsequent system definition and comparison efforts.

  15. THE COOLING REQUIREMENTS AND PROCESS SYSTEMS OF THE SOUTH AFRICAN RESEARCH REACTOR, SAFARI 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colley, J.R.

    1962-12-01

    The SAFARI 1 research reactor is cooled and moderated by light water. There are three process systems, a primary water system which cools the reactor core and surroundings, a pool water system, and a secondary water system which removes the heat from the primary and pool systems. The cooling requirements for the reactor core and experimental facilities are outlined, and the cooling and purification functions of the three process systems are described. (auth)

  16. USE OF INDICATOR ORGANISMS FOR DETERMINING PROCESS EFFECTIVENESS

    EPA Science Inventory

    Wastewaters, process effluents and treatment process residuals contain a variety of microorganisms. Many factors influence their densities as they move through collection systems and process equipment. Biological treatment systems rely on the catabolic processes of such microor...

  17. Modeling of outpatient prescribing process in iran: a gateway toward electronic prescribing system.

    PubMed

    Ahmadi, Maryam; Samadbeik, Mahnaz; Sadoughi, Farahnaz

    2014-01-01

    Implementation of electronic prescribing system can overcome many problems of the paper prescribing system, and provide numerous opportunities of more effective and advantageous prescribing. Successful implementation of such a system requires complete and deep understanding of work content, human force, and workflow of paper prescribing. The current study was designed in order to model the current business process of outpatient prescribing in Iran and clarify different actions during this process. In order to describe the prescribing process and the system features in Iran, the methodology of business process modeling and analysis was used in the present study. The results of the process documentation were analyzed using a conceptual model of workflow elements and the technique of modeling "As-Is" business processes. Analysis of the current (as-is) prescribing process demonstrated that Iran stood at the first levels of sophistication in graduated levels of electronic prescribing, namely electronic prescription reference, and that there were problematic areas including bottlenecks, redundant and duplicated work, concentration of decision nodes, and communicative weaknesses among stakeholders of the process. Using information technology in some activities of medication prescription in Iran has not eliminated the dependence of the stakeholders on paper-based documents and prescriptions. Therefore, it is necessary to implement proper system programming in order to support change management and solve the problems in the existing prescribing process. To this end, a suitable basis should be provided for reorganization and improvement of the prescribing process for the future electronic systems.

  18. Flat-plate solar array project: Experimental process system development unit for producing semiconductor-grade silicon using the silane-to-silicon process

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The engineering design, fabrication, assembly, operation, economic analysis, and process support research and development for an Experimental Process System Development Unit for producing semiconductor-grade silicon using the slane-to-silicon process are reported. The design activity was completed. About 95% of purchased equipment was received. The draft of the operations manual was about 50% complete and the design of the free-space system continued. The system using silicon power transfer, melting, and shotting on a psuedocontinuous basis was demonstrated.

  19. A new intuitionistic fuzzy rule-based decision-making system for an operating system process scheduler.

    PubMed

    Butt, Muhammad Arif; Akram, Muhammad

    2016-01-01

    We present a new intuitionistic fuzzy rule-based decision-making system based on intuitionistic fuzzy sets for a process scheduler of a batch operating system. Our proposed intuitionistic fuzzy scheduling algorithm, inputs the nice value and burst time of all available processes in the ready queue, intuitionistically fuzzify the input values, triggers appropriate rules of our intuitionistic fuzzy inference engine and finally calculates the dynamic priority (dp) of all the processes in the ready queue. Once the dp of every process is calculated the ready queue is sorted in decreasing order of dp of every process. The process with maximum dp value is sent to the central processing unit for execution. Finally, we show complete working of our algorithm on two different data sets and give comparisons with some standard non-preemptive process schedulers.

  20. Liquid and Gaseous Waste Operations Department annual operating report CY 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maddox, J.J.; Scott, C.B.

    1997-03-01

    This annual report summarizes operating activities dealing with the process waste system, the liquid low-level waste system, and the gaseous waste system. It also describes upgrade activities dealing with the process and liquid low-level waste systems, the cathodic protection system, a stack ventilation system, and configuration control. Maintenance activities are described dealing with nonradiological wastewater treatment plant, process waste treatment plant and collection system, liquid low-level waste system, and gaseous waste system. Miscellaneous activities include training, audits/reviews/tours, and environmental restoration support.

  1. 10 CFR 1017.28 - Processing on Automated Information Systems (AIS).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Processing on Automated Information Systems (AIS). 1017.28... UNCLASSIFIED CONTROLLED NUCLEAR INFORMATION Physical Protection Requirements § 1017.28 Processing on Automated Information Systems (AIS). UCNI may be processed or produced on any AIS that complies with the guidance in OMB...

  2. 40 CFR 63.444 - Standards for the pulping system at sulfite processes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Standards for the pulping system at sulfite processes. (a) The owner or operator of each sulfite process... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Standards for the pulping system at sulfite processes. 63.444 Section 63.444 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  3. A Flexible Pilot-Scale Setup for Real-Time Studies in Process Systems Engineering

    ERIC Educational Resources Information Center

    Panjapornpon, Chanin; Fletcher, Nathan; Soroush, Masoud

    2006-01-01

    This manuscript describes a flexible, pilot-scale setup that can be used for training students and carrying out research in process systems engineering. The setup allows one to study a variety of process systems engineering concepts such as design feasibility, design flexibility, control configuration selection, parameter estimation, process and…

  4. An Information System Development Method Connecting Business Process Modeling and its Experimental Evaluation

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Kojima, Yoshiyuki; Hirabayashi, Syuichi; Koizumi, Hisao

    Business process modeling (BPM) is gaining attention as a measure of analysis and improvement of the business process. BPM analyses the current business process as an AS-IS model and solves problems to improve the current business and moreover it aims to create a business process, which produces values, as a TO-BE model. However, researches of techniques that connect the business process improvement acquired by BPM to the implementation of the information system seamlessly are rarely reported. If the business model obtained by BPM is converted into UML, and the implementation can be carried out by the technique of UML, we can expect the improvement in efficiency of information system implementation. In this paper, we describe a method of the system development, which converts the process model obtained by BPM into UML and the method is evaluated by modeling a prototype of a parts procurement system. In the evaluation, comparison with the case where the system is implemented by the conventional UML technique without going via BPM is performed.

  5. Understanding how replication processes can maintain systems away from equilibrium using Algorithmic Information Theory.

    PubMed

    Devine, Sean D

    2016-02-01

    Replication can be envisaged as a computational process that is able to generate and maintain order far-from-equilibrium. Replication processes, can self-regulate, as the drive to replicate can counter degradation processes that impact on a system. The capability of replicated structures to access high quality energy and eject disorder allows Landauer's principle, in conjunction with Algorithmic Information Theory, to quantify the entropy requirements to maintain a system far-from-equilibrium. Using Landauer's principle, where destabilising processes, operating under the second law of thermodynamics, change the information content or the algorithmic entropy of a system by ΔH bits, replication processes can access order, eject disorder, and counter the change without outside interventions. Both diversity in replicated structures, and the coupling of different replicated systems, increase the ability of the system (or systems) to self-regulate in a changing environment as adaptation processes select those structures that use resources more efficiently. At the level of the structure, as selection processes minimise the information loss, the irreversibility is minimised. While each structure that emerges can be said to be more entropically efficient, as such replicating structures proliferate, the dissipation of the system as a whole is higher than would be the case for inert or simpler structures. While a detailed application to most real systems would be difficult, the approach may well be useful in understanding incremental changes to real systems and provide broad descriptions of system behaviour. Copyright © 2016 The Author. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. A global "imaging'' view on systems approaches in immunology.

    PubMed

    Ludewig, Burkhard; Stein, Jens V; Sharpe, James; Cervantes-Barragan, Luisa; Thiel, Volker; Bocharov, Gennady

    2012-12-01

    The immune system exhibits an enormous complexity. High throughput methods such as the "-omic'' technologies generate vast amounts of data that facilitate dissection of immunological processes at ever finer resolution. Using high-resolution data-driven systems analysis, causal relationships between complex molecular processes and particular immunological phenotypes can be constructed. However, processes in tissues, organs, and the organism itself (so-called higher level processes) also control and regulate the molecular (lower level) processes. Reverse systems engineering approaches, which focus on the examination of the structure, dynamics and control of the immune system, can help to understand the construction principles of the immune system. Such integrative mechanistic models can properly describe, explain, and predict the behavior of the immune system in health and disease by combining both higher and lower level processes. Moving from molecular and cellular levels to a multiscale systems understanding requires the development of methodologies that integrate data from different biological levels into multiscale mechanistic models. In particular, 3D imaging techniques and 4D modeling of the spatiotemporal dynamics of immune processes within lymphoid tissues are central for such integrative approaches. Both dynamic and global organ imaging technologies will be instrumental in facilitating comprehensive multiscale systems immunology analyses as discussed in this review. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Applications of massively parallel computers in telemetry processing

    NASA Technical Reports Server (NTRS)

    El-Ghazawi, Tarek A.; Pritchard, Jim; Knoble, Gordon

    1994-01-01

    Telemetry processing refers to the reconstruction of full resolution raw instrumentation data with artifacts, of space and ground recording and transmission, removed. Being the first processing phase of satellite data, this process is also referred to as level-zero processing. This study is aimed at investigating the use of massively parallel computing technology in providing level-zero processing to spaceflights that adhere to the recommendations of the Consultative Committee on Space Data Systems (CCSDS). The workload characteristics, of level-zero processing, are used to identify processing requirements in high-performance computing systems. An example of level-zero functions on a SIMD MPP, such as the MasPar, is discussed. The requirements in this paper are based in part on the Earth Observing System (EOS) Data and Operation System (EDOS).

  8. The Systems Engineering Process for Human Support Technology Development

    NASA Technical Reports Server (NTRS)

    Jones, Harry

    2005-01-01

    Systems engineering is designing and optimizing systems. This paper reviews the systems engineering process and indicates how it can be applied in the development of advanced human support systems. Systems engineering develops the performance requirements, subsystem specifications, and detailed designs needed to construct a desired system. Systems design is difficult, requiring both art and science and balancing human and technical considerations. The essential systems engineering activity is trading off and compromising between competing objectives such as performance and cost, schedule and risk. Systems engineering is not a complete independent process. It usually supports a system development project. This review emphasizes the NASA project management process as described in NASA Procedural Requirement (NPR) 7120.5B. The process is a top down phased approach that includes the most fundamental activities of systems engineering - requirements definition, systems analysis, and design. NPR 7120.5B also requires projects to perform the engineering analyses needed to ensure that the system will operate correctly with regard to reliability, safety, risk, cost, and human factors. We review the system development project process, the standard systems engineering design methodology, and some of the specialized systems analysis techniques. We will discuss how they could apply to advanced human support systems development. The purpose of advanced systems development is not directly to supply human space flight hardware, but rather to provide superior candidate systems that will be selected for implementation by future missions. The most direct application of systems engineering is in guiding the development of prototype and flight experiment hardware. However, anticipatory systems engineering of possible future flight systems would be useful in identifying the most promising development projects.

  9. Test processing system (SEE)

    NASA Technical Reports Server (NTRS)

    Gaulene, P.

    1986-01-01

    The SEE data processing system, developed in 1985, manages and process test results. General information is provided on the SEE system: objectives, characteristics, basic principles, general organization, and operation. Full documentation is accessible by computer using the HELP SEE command.

  10. Coal conversion systems design and process modeling. Volume 1: Application of MPPR and Aspen computer models

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The development of a coal gasification system design and mass and energy balance simulation program for the TVA and other similar facilities is described. The materials-process-product model (MPPM) and the advanced system for process engineering (ASPEN) computer program were selected from available steady state and dynamic models. The MPPM was selected to serve as the basis for development of system level design model structure because it provided the capability for process block material and energy balance and high-level systems sizing and costing. The ASPEN simulation serves as the basis for assessing detailed component models for the system design modeling program. The ASPEN components were analyzed to identify particular process blocks and data packages (physical properties) which could be extracted and used in the system design modeling program. While ASPEN physical properties calculation routines are capable of generating physical properties required for process simulation, not all required physical property data are available, and must be user-entered.

  11. Applications of High-speed motion analysis system on Solid Rocket Motor (SRM)

    NASA Astrophysics Data System (ADS)

    Liu, Yang; He, Guo-qiang; Li, Jiang; Liu, Pei-jin; Chen, Jian

    2007-01-01

    High-speed motion analysis system could record images up to 12,000fps and analyzed with the image processing system. The system stored data and images directly in electronic memory convenient for managing and analyzing. The high-speed motion analysis system and the X-ray radiography system were established the high-speed real-time X-ray radiography system, which could diagnose and measure the dynamic and high-speed process in opaque. The image processing software was developed for improve quality of the original image for acquiring more precise information. The typical applications of high-speed motion analysis system on solid rocket motor (SRM) were introduced in the paper. The research of anomalous combustion of solid propellant grain with defects, real-time measurement experiment of insulator eroding, explosion incision process of motor, structure and wave character of plume during the process of ignition and flameout, measurement of end burning of solid propellant, measurement of flame front and compatibility between airplane and missile during the missile launching were carried out using high-speed motion analysis system. The significative results were achieved through the research. Aim at application of high-speed motion analysis system on solid rocket motor, the key problem, such as motor vibrancy, electrical source instability, geometry aberrance, and yawp disturbance, which damaged the image quality, was solved. The image processing software was developed which improved the capability of measuring the characteristic of image. The experimental results showed that the system was a powerful facility to study instantaneous and high-speed process in solid rocket motor. With the development of the image processing technique, the capability of high-speed motion analysis system was enhanced.

  12. Ku-band signal design study. [space shuttle orbiter data processing network

    NASA Technical Reports Server (NTRS)

    Rubin, I.

    1978-01-01

    Analytical tools, methods and techniques for assessing the design and performance of the space shuttle orbiter data processing system (DPS) are provided. The computer data processing network is evaluated in the key areas of queueing behavior synchronization and network reliability. The structure of the data processing network is described as well as the system operation principles and the network configuration. The characteristics of the computer systems are indicated. System reliability measures are defined and studied. System and network invulnerability measures are computed. Communication path and network failure analysis techniques are included.

  13. MIUS wastewater technology evaluation

    NASA Technical Reports Server (NTRS)

    Poradek, J. C.

    1976-01-01

    A modular integrated utility system wastewater-treatment process is described. Research in the field of wastewater treatment is reviewed, treatment processes are specified and evaluated, and recommendations for system use are made. The treatment processes evaluated are in the broad categories of preparatory, primary, secondary, and tertiary treatment, physical-chemical processing, dissolved-solids removal, disinfection, sludge processing, and separate systems. Capital, operating, and maintenance costs are estimated, and extensive references are given.

  14. Introduction to Radar Signal and Data Processing: The Opportunity

    DTIC Science & Technology

    2006-09-01

    SpA) Director of Analysis of Integrated Systems Group Via Tiburtina Km. 12.400 00131 Rome ITALY e.mail: afarina@selex-si.com Key words: radar...signal processing, data processing, adaptivity, space-time adaptive processing, knowledge based systems , CFAR. 1. SUMMARY This paper introduces to...the lecture series dedicated to the knowledge-based radar signal and data processing. Knowledge-based expert system (KBS) is in the realm of

  15. [Construction of NIRS-based process analytical system for production of salvianolic acid for injection and relative discussion].

    PubMed

    Zhang, Lei; Yue, Hong-Shui; Ju, Ai-Chun; Ye, Zheng-Liang

    2016-10-01

    Currently, near infrared spectroscopy (NIRS) has been considered as an efficient tool for achieving process analytical technology(PAT) in the manufacture of traditional Chinese medicine (TCM) products. In this article, the NIRS based process analytical system for the production of salvianolic acid for injection was introduced. The design of the process analytical system was described in detail, including the selection of monitored processes and testing mode, and potential risks that should be avoided. Moreover, the development of relative technologies was also presented, which contained the establishment of the monitoring methods for the elution of polyamide resin and macroporous resin chromatography processes, as well as the rapid analysis method for finished products. Based on author's experience of research and work, several issues in the application of NIRS to the process monitoring and control in TCM production were then raised, and some potential solutions were also discussed. The issues include building the technical team for process analytical system, the design of the process analytical system in the manufacture of TCM products, standardization of the NIRS-based analytical methods, and improving the management of process analytical system. Finally, the prospect for the application of NIRS in the TCM industry was put forward. Copyright© by the Chinese Pharmaceutical Association.

  16. Reading comprehension and working memory in learning-disabled readers: Is the phonological loop more important than the executive system?

    PubMed

    Swanson, H L

    1999-01-01

    This investigation explores the contribution of two working memory systems (the articulatory loop and the central executive) to the performance differences between learning-disabled (LD) and skilled readers. Performances of LD, chronological age (CA) matched, and reading level-matched children were compared on measures of phonological processing accuracy and speed (articulatory system), long-term memory (LTM) accuracy and speed, and executive processing. The results indicated that (a) LD readers were inferior on measures of articulatory, LTM, and executive processing; (b) LD readers were superior to RL readers on measures of executive processing, but were comparable to RL readers on measures of the articulatory and LTM system; (c) executive processing differences remained significant between LD and CA-matched children when measures of reading comprehension, articulatory processes, and LTM processes were partialed from the analysis; and (d) executive processing contributed significant variance to reading comprehension when measures of the articulatory and LTM systems were entered into a hierarchical regression model. In summary, LD readers experience constraints in the articulatory and LTM system, but constraints mediate only some of the influence of executive processing on reading comprehension. Further, LD readers suffer executive processing problems nonspecific to their reading comprehension problems. Copyright 1999 Academic Press.

  17. Putting the Power of Configuration in the Hands of the Users

    NASA Technical Reports Server (NTRS)

    Al-Shihabi, Mary-Jo; Brown, Mark; Rigolini, Marianne

    2011-01-01

    Goal was to reduce the overall cost of human space flight while maintaining the most demanding standards for safety and mission success. In support of this goal, a project team was chartered to replace 18 legacy Space Shuttle nonconformance processes and systems with one fully integrated system Problem Reporting and Corrective Action (PRACA) processes provide a closed-loop system for the identification, disposition, resolution, closure, and reporting of all Space Shuttle hardware/software problems PRACA processes are integrated throughout the Space Shuttle organizational processes and are critical to assuring a safe and successful program Primary Project Objectives Develop a fully integrated system that provides an automated workflow with electronic signatures Support multiple NASA programs and contracts with a single "system" architecture Define standard processes, implement best practices, and minimize process variations

  18. Providing security for automated process control systems at hydropower engineering facilities

    NASA Astrophysics Data System (ADS)

    Vasiliev, Y. S.; Zegzhda, P. D.; Zegzhda, D. P.

    2016-12-01

    This article suggests the concept of a cyberphysical system to manage computer security of automated process control systems at hydropower engineering facilities. According to the authors, this system consists of a set of information processing tools and computer-controlled physical devices. Examples of cyber attacks on power engineering facilities are provided, and a strategy of improving cybersecurity of hydropower engineering systems is suggested. The architecture of the multilevel protection of the automated process control system (APCS) of power engineering facilities is given, including security systems, control systems, access control, encryption, secure virtual private network of subsystems for monitoring and analysis of security events. The distinctive aspect of the approach is consideration of interrelations and cyber threats, arising when SCADA is integrated with the unified enterprise information system.

  19. The Interaction of Spacecraft Cabin Atmospheric Quality and Water Processing System Performance

    NASA Technical Reports Server (NTRS)

    Perry, Jay L.; Croomes, Scott D. (Technical Monitor)

    2002-01-01

    Although designed to remove organic contaminants from a variety of waste water streams, the planned U.S.- and present Russian-provided water processing systems onboard the International Space Station (ISS) have capacity limits for some of the more common volatile cleaning solvents used for housekeeping purposes. Using large quantities of volatile cleaning solvents during the ground processing and in-flight operational phases of a crewed spacecraft such as the ISS can lead to significant challenges to the water processing systems. To understand the challenges facing the management of water processing capacity, the relationship between cabin atmospheric quality and humidity condensate loading is presented. This relationship is developed as a tool to determine the cabin atmospheric loading that may compromise water processing system performance. A comparison of cabin atmospheric loading with volatile cleaning solvents from ISS, Mir, and Shuttle are presented to predict acceptable limits to maintain optimal water processing system performance.

  20. Woods Hole Image Processing System Software implementation; using NetCDF as a software interface for image processing

    USGS Publications Warehouse

    Paskevich, Valerie F.

    1992-01-01

    The Branch of Atlantic Marine Geology has been involved in the collection, processing and digital mosaicking of high, medium and low-resolution side-scan sonar data during the past 6 years. In the past, processing and digital mosaicking has been accomplished with a dedicated, shore-based computer system. With the need to process sidescan data in the field with increased power and reduced cost of major workstations, a need to have an image processing package on a UNIX based computer system which could be utilized in the field as well as be more generally available to Branch personnel was identified. This report describes the initial development of that package referred to as the Woods Hole Image Processing System (WHIPS). The software was developed using the Unidata NetCDF software interface to allow data to be more readily portable between different computer operating systems.

  1. Methods, media and systems for managing a distributed application running in a plurality of digital processing devices

    DOEpatents

    Laadan, Oren; Nieh, Jason; Phung, Dan

    2012-10-02

    Methods, media and systems for managing a distributed application running in a plurality of digital processing devices are provided. In some embodiments, a method includes running one or more processes associated with the distributed application in virtualized operating system environments on a plurality of digital processing devices, suspending the one or more processes, and saving network state information relating to network connections among the one or more processes. The method further include storing process information relating to the one or more processes, recreating the network connections using the saved network state information, and restarting the one or more processes using the stored process information.

  2. 42 CFR 433.116 - FFP for operation of mechanized claims processing and information retrieval systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and information retrieval systems. 433.116 Section 433.116 Public Health CENTERS FOR MEDICARE... FISCAL ADMINISTRATION Mechanized Claims Processing and Information Retrieval Systems § 433.116 FFP for operation of mechanized claims processing and information retrieval systems. (a) Subject to 42 CFR 433.113(c...

  3. Dual Systems Competence [Image Omitted] Procedural Processing: A Relational Developmental Systems Approach to Reasoning

    ERIC Educational Resources Information Center

    Ricco, Robert B.; Overton, Willis F.

    2011-01-01

    Many current psychological models of reasoning minimize the role of deductive processes in human thought. In the present paper, we argue that deduction is an important part of ordinary cognition and we propose that a dual systems Competence [image omitted] Procedural processing model conceptualized within relational developmental systems theory…

  4. 49 CFR 232.503 - Process to introduce new brake system technology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Process to introduce new brake system technology... Technology § 232.503 Process to introduce new brake system technology. (a) Pursuant to the procedures... brake system technology, prior to implementing the plan. (b) Each railroad shall complete a pre-revenue...

  5. 49 CFR 232.503 - Process to introduce new brake system technology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Process to introduce new brake system technology... Technology § 232.503 Process to introduce new brake system technology. (a) Pursuant to the procedures... brake system technology, prior to implementing the plan. (b) Each railroad shall complete a pre-revenue...

  6. 49 CFR 232.503 - Process to introduce new brake system technology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Process to introduce new brake system technology... Technology § 232.503 Process to introduce new brake system technology. (a) Pursuant to the procedures... brake system technology, prior to implementing the plan. (b) Each railroad shall complete a pre-revenue...

  7. 49 CFR 232.503 - Process to introduce new brake system technology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Process to introduce new brake system technology... Technology § 232.503 Process to introduce new brake system technology. (a) Pursuant to the procedures... brake system technology, prior to implementing the plan. (b) Each railroad shall complete a pre-revenue...

  8. 49 CFR 232.503 - Process to introduce new brake system technology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Process to introduce new brake system technology... Technology § 232.503 Process to introduce new brake system technology. (a) Pursuant to the procedures... brake system technology, prior to implementing the plan. (b) Each railroad shall complete a pre-revenue...

  9. Automated processing of whole blood units: operational value and in vitro quality of final blood components

    PubMed Central

    Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz

    2012-01-01

    Background The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Materials and methods Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. Results The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. Discussion These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement. PMID:22044958

  10. Automated processing of whole blood units: operational value and in vitro quality of final blood components.

    PubMed

    Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz

    2012-01-01

    The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.

  11. Software architecture for intelligent image processing using Prolog

    NASA Astrophysics Data System (ADS)

    Jones, Andrew C.; Batchelor, Bruce G.

    1994-10-01

    We describe a prototype system for interactive image processing using Prolog, implemented by the first author on an Apple Macintosh computer. This system is inspired by Prolog+, but differs from it in two particularly important respects. The first is that whereas Prolog+ assumes the availability of dedicated image processing hardware, with which the Prolog system communicates, our present system implements image processing functions in software using the C programming language. The second difference is that although our present system supports Prolog+ commands, these are implemented in terms of lower-level Prolog predicates which provide a more flexible approach to image manipulation. We discuss the impact of the Apple Macintosh operating system upon the implementation of the image-processing functions, and the interface between these functions and the Prolog system. We also explain how the Prolog+ commands have been implemented. The system described in this paper is a fairly early prototype, and we outline how we intend to develop the system, a task which is expedited by the extensible architecture we have implemented.

  12. VerifEYE: a real-time meat inspection system for the beef processing industry

    NASA Astrophysics Data System (ADS)

    Kocak, Donna M.; Caimi, Frank M.; Flick, Rick L.; Elharti, Abdelmoula

    2003-02-01

    Described is a real-time meat inspection system developed for the beef processing industry by eMerge Interactive. Designed to detect and localize trace amounts of contamination on cattle carcasses in the packing process, the system affords the beef industry an accurate, high speed, passive optical method of inspection. Using a method patented by United States Department of Agriculture and Iowa State University, the system takes advantage of fluorescing chlorophyll found in the animal's diet and therefore the digestive track to allow detection and imaging of contaminated areas that may harbor potentially dangerous microbial pathogens. Featuring real-time image processing and documentation of performance, the system can be easily integrated into a processing facility's Hazard Analysis and Critical Control Point quality assurance program. This paper describes the VerifEYE carcass inspection and removal verification system. Results indicating the feasibility of the method, as well as field data collected using a prototype system during four university trials conducted in 2001 are presented. Two successful demonstrations using the prototype system were held at a major U.S. meat processing facility in early 2002.

  13. Automated process control for plasma etching

    NASA Astrophysics Data System (ADS)

    McGeown, Margaret; Arshak, Khalil I.; Murphy, Eamonn

    1992-06-01

    This paper discusses the development and implementation of a rule-based system which assists in providing automated process control for plasma etching. The heart of the system is to establish a correspondence between a particular data pattern -- sensor or data signals -- and one or more modes of failure, i.e., a data-driven monitoring approach. The objective of this rule based system, PLETCHSY, is to create a program combining statistical process control (SPC) and fault diagnosis to help control a manufacturing process which varies over time. This can be achieved by building a process control system (PCS) with the following characteristics. A facility to monitor the performance of the process by obtaining and analyzing the data relating to the appropriate process variables. Process sensor/status signals are input into an SPC module. If trends are present, the SPC module outputs the last seven control points, a pattern which is represented by either regression or scoring. The pattern is passed to the rule-based module. When the rule-based system recognizes a pattern, it starts the diagnostic process using the pattern. If the process is considered to be going out of control, advice is provided about actions which should be taken to bring the process back into control.

  14. RDD-100 and the systems engineering process

    NASA Technical Reports Server (NTRS)

    Averill, Robert D.

    1994-01-01

    An effective systems engineering approach applied through the project life cycle can help Langley produce a better product. This paper demonstrates how an enhanced systems engineering process for in-house flight projects assures that each system will achieve its goals with quality performance and within planned budgets and schedules. This paper also describes how the systems engineering process can be used in combination with available software tools.

  15. The Defense Systems Acquisition and Review Council

    DTIC Science & Technology

    1976-09-15

    THE DEFENSE SYSTEMS ACQUISITION AND REVIEW COUNCIL.. A Study of Areas of Consideration Affecting the Functions and Process of Defense Major...COUNfIL: 4 Study of Areas of Considerationi Affecting/he Functions and Process of Defense _- 1 Major Systems Acquisition. , ; O,. v AUTHOR(e) I. C...Studies DSARC -- Functions and Process OSDCAIG *, Army Systems . A - =A -- he Defense Systems Acquisition Review Council (DSARC) was created to assume

  16. Overview of the production of sintered SiC optics and optical sub-assemblies

    NASA Astrophysics Data System (ADS)

    Williams, S.; Deny, P.

    2005-08-01

    The following is an overview on sintered silicon carbide (SSiC) material properties and processing requirements for the manufacturing of components for advanced technology optical systems. The overview will compare SSiC material properties to typical materials used for optics and optical structures. In addition, it will review manufacturing processes required to produce optical components in detail by process step. The process overview will illustrate current manufacturing process and concepts to expand the process size capability. The overview will include information on the substantial capital equipment employed in the manufacturing of SSIC. This paper will also review common in-process inspection methodology and design rules. The design rules are used to improve production yield, minimize cost, and maximize the inherent benefits of SSiC for optical systems. Optimizing optical system designs for a SSiC manufacturing process will allow systems designers to utilize SSiC as a low risk, cost competitive, and fast cycle time technology for next generation optical systems.

  17. Field Artillery Ammunition Processing System (FAAPS) concept evaluation study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kring, C.T.; Babcock, S.M.; Watkin, D.C.

    1992-06-01

    The Field Artillery Ammunition Processing System (FAAPS) is an initiative to introduce a palletized load system (PLS) that is transportable with an automated ammunition processing and storage system for use on the battlefield. System proponents have targeted a 20% increase in the ammunition processing rate over the current operation while simultaneously reducing the total number of assigned field artillery battalion personnel by 30. The overall objective of the FAAPS Project is the development and demonstration of an improved process to accomplish these goals. The initial phase of the FAAPS Project and the subject of this study is the FAAPS conceptmore » evaluation. The concept evaluation consists of (1) identifying assumptions and requirements, (2) documenting the process flow, (3) identifying and evaluating technologies available to accomplish the necessary ammunition processing and storage operations, and (4) presenting alternative concepts with associated costs, processing rates, and manpower requirements for accomplishing the operation. This study provides insight into the achievability of the desired objectives.« less

  18. Field Artillery Ammunition Processing System (FAAPS) concept evaluation study. Ammunition Logistics Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kring, C.T.; Babcock, S.M.; Watkin, D.C.

    1992-06-01

    The Field Artillery Ammunition Processing System (FAAPS) is an initiative to introduce a palletized load system (PLS) that is transportable with an automated ammunition processing and storage system for use on the battlefield. System proponents have targeted a 20% increase in the ammunition processing rate over the current operation while simultaneously reducing the total number of assigned field artillery battalion personnel by 30. The overall objective of the FAAPS Project is the development and demonstration of an improved process to accomplish these goals. The initial phase of the FAAPS Project and the subject of this study is the FAAPS conceptmore » evaluation. The concept evaluation consists of (1) identifying assumptions and requirements, (2) documenting the process flow, (3) identifying and evaluating technologies available to accomplish the necessary ammunition processing and storage operations, and (4) presenting alternative concepts with associated costs, processing rates, and manpower requirements for accomplishing the operation. This study provides insight into the achievability of the desired objectives.« less

  19. Graphics Processing Unit (GPU) implementation of image processing algorithms to improve system performance of the Control, Acquisition, Processing, and Image Display System (CAPIDS) of the Micro-Angiographic Fluoroscope (MAF).

    PubMed

    Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S

    2012-02-23

    We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.

  20. Welding process modelling and control

    NASA Technical Reports Server (NTRS)

    Romine, Peter L.; Adenwala, Jinen A.

    1993-01-01

    The research and analysis performed, and software developed, and hardware/software recommendations made during 1992 in development of the PC-based data acquisition system for support of Welding Process Modeling and Control is reported. A need was identified by the Metals Processing Branch of NASA Marshall Space Flight Center, for a mobile data aquisition and analysis system, customized for welding measurement and calibration. Several hardware configurations were evaluated and a PC-based system was chosen. The Welding Measurement System (WMS) is a dedicated instrument, strictly for the use of data aquisition and analysis. Although the WMS supports many of the functions associated with the process control, it is not the intention for this system to be used for welding process control.

  1. 42 CFR 433.112 - FFP for design, development, installation or enhancement of mechanized claims processing and...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... enhancement of mechanized claims processing and information retrieval systems. 433.112 Section 433.112 Public... processing and information retrieval systems. (a) Subject to paragraph (c) of this section, FFP is available... enhancement of a mechanized claims processing and information retrieval system only if the APD is approved by...

  2. 42 CFR 433.112 - FFP for design, development, installation or enhancement of mechanized claims processing and...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... enhancement of mechanized claims processing and information retrieval systems. 433.112 Section 433.112 Public... processing and information retrieval systems. (a) Subject to paragraph (c) of this section, FFP is available... enhancement of a mechanized claims processing and information retrieval system only if the APD is approved by...

  3. 42 CFR 433.112 - FFP for design, development, installation or enhancement of mechanized claims processing and...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... enhancement of mechanized claims processing and information retrieval systems. 433.112 Section 433.112 Public... processing and information retrieval systems. (a) Subject to paragraph (c) of this section, FFP is available... enhancement of a mechanized claims processing and information retrieval system only if the APD is approved by...

  4. 42 CFR 433.112 - FFP for design, development, installation or enhancement of mechanized claims processing and...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... enhancement of mechanized claims processing and information retrieval systems. 433.112 Section 433.112 Public... processing and information retrieval systems. (a) Subject to paragraph (c) of this section, FFP is available... enhancement of a mechanized claims processing and information retrieval system only if the APD is approved by...

  5. Autonomous Agents for Dynamic Process Planning in the Flexible Manufacturing System

    NASA Astrophysics Data System (ADS)

    Nik Nejad, Hossein Tehrani; Sugimura, Nobuhiro; Iwamura, Koji; Tanimizu, Yoshitaka

    Rapid changes of market demands and pressures of competition require manufacturers to maintain highly flexible manufacturing systems to cope with a complex manufacturing environment. This paper deals with development of an agent-based architecture of dynamic systems for incremental process planning in the manufacturing systems. In consideration of alternative manufacturing processes and machine tools, the process plans and the schedules of the manufacturing resources are generated incrementally and dynamically. A negotiation protocol is discussed, in this paper, to generate suitable process plans for the target products real-timely and dynamically, based on the alternative manufacturing processes. The alternative manufacturing processes are presented by the process plan networks discussed in the previous paper, and the suitable process plans are searched and generated to cope with both the dynamic changes of the product specifications and the disturbances of the manufacturing resources. We initiatively combine the heuristic search algorithms of the process plan networks with the negotiation protocols, in order to generate suitable process plans in the dynamic manufacturing environment.

  6. Feasibility study of an Integrated Program for Aerospace vehicle Design (IPAD). Volume 1A: Summary

    NASA Technical Reports Server (NTRS)

    Miller, R. E., Jr.; Redhed, D. D.; Kawaguchi, A. S.; Hansen, S. D.; Southall, J. W.

    1973-01-01

    IPAD was defined as a total system oriented to the product design process. This total system was designed to recognize the product design process, individuals and their design process tasks, and the computer-based IPAD System to aid product design. Principal elements of the IPAD System include the host computer and its interactive system software, new executive and data management software, and an open-ended IPAD library of technical programs to match the intended product design process. The basic goal of the IPAD total system is to increase the productivity of the product design organization. Increases in individual productivity were feasible through automation and computer support of routine information handling. Such proven automation can directly decrease cost and flowtime in the product design process.

  7. Spot restoration for GPR image post-processing

    DOEpatents

    Paglieroni, David W; Beer, N. Reginald

    2014-05-20

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

  8. Thermal performance of a photographic laboratory process: Solar Hot Water System

    NASA Technical Reports Server (NTRS)

    Walker, J. A.; Jensen, R. N.

    1982-01-01

    The thermal performance of a solar process hot water system is described. The system was designed to supply 22,000 liters (5,500 gallons) per day of 66 C (150 F) process water for photographic processing. The 328 sq m (3,528 sq. ft.) solar field has supplied 58% of the thermal energy for the system. Techniques used for analyzing various thermal values are given. Load and performance factors and the resulting solar contribution are discussed.

  9. The process of development of a prioritization tool for a clinical decision support build within a computerized provider order entry system: Experiences from St Luke's Health System.

    PubMed

    Wolf, Matthew; Miller, Suzanne; DeJong, Doug; House, John A; Dirks, Carl; Beasley, Brent

    2016-09-01

    To establish a process for the development of a prioritization tool for a clinical decision support build within a computerized provider order entry system and concurrently to prioritize alerts for Saint Luke's Health System. The process of prioritizing clinical decision support alerts included (a) consensus sessions to establish a prioritization process and identify clinical decision support alerts through a modified Delphi process and (b) a clinical decision support survey to validate the results. All members of our health system's physician quality organization, Saint Luke's Care as well as clinicians, administrators, and pharmacy staff throughout Saint Luke's Health System, were invited to participate in this confidential survey. The consensus sessions yielded a prioritization process through alert contextualization and associated Likert-type scales. Utilizing this process, the clinical decision support survey polled the opinions of 850 clinicians with a 64.7 percent response rate. Three of the top rated alerts were approved for the pre-implementation build at Saint Luke's Health System: Acute Myocardial Infarction Core Measure Sets, Deep Vein Thrombosis Prophylaxis within 4 h, and Criteria for Sepsis. This study establishes a process for developing a prioritization tool for a clinical decision support build within a computerized provider order entry system that may be applicable to similar institutions. © The Author(s) 2015.

  10. The embodied embedded character of system 1 processing.

    PubMed

    Bellini-Leite, Samuel de Castro

    2013-01-01

    In the last thirty years, a relatively large group of cognitive scientists have begun characterising the mind in terms of two distinct, relatively autonomous systems. To account for paradoxes in empirical results of studies mainly on reasoning, Dual Process Theories were developed. Such Dual Process Theories generally agree that System 1 is rapid, automatic, parallel, and heuristic-based and System 2 is slow, capacity-demanding, sequential, and related to consciousness. While System 2 can still be decently understood from a traditional cognitivist approach, I will argue that it is essential for System 1 processing to be comprehended in an Embodied Embedded approach to Cognition.

  11. The Embodied Embedded Character of System 1 Processing

    PubMed Central

    Bellini-Leite, Samuel de Castro

    2013-01-01

    In the last thirty years, a relatively large group of cognitive scientists have begun characterising the mind in terms of two distinct, relatively autonomous systems. To account for paradoxes in empirical results of studies mainly on reasoning, Dual Process Theories were developed. Such Dual Process Theories generally agree that System 1 is rapid, automatic, parallel, and heuristic-based and System 2 is slow, capacity-demanding, sequential, and related to consciousness. While System 2 can still be decently understood from a traditional cognitivist approach, I will argue that it is essential for System 1 processing to be comprehended in an Embodied Embedded approach to Cognition. PMID:23678245

  12. ISO 9000 and/or Systems Engineering Capability Maturity Model?

    NASA Technical Reports Server (NTRS)

    Gholston, Sampson E.

    2002-01-01

    For businesses and organizations to remain competitive today they must have processes and systems in place that will allow them to first identify customer needs and then develop products/processes that will meet or exceed the customers needs and expectations. Customer needs, once identified, are normally stated as requirements. Designers can then develop products/processes that will meet these requirements. Several functions, such as quality management and systems engineering management are used to assist product development teams in the development process. Both functions exist in all organizations and both have a similar objective, which is to ensure that developed processes will meet customer requirements. Are efforts in these organizations being duplicated? Are both functions needed by organizations? What are the similarities and differences between the functions listed above? ISO 9000 is an international standard of goods and services. It sets broad requirements for the assurance of quality and for management's involvement. It requires organizations to document the processes and to follow these documented processes. ISO 9000 gives customers assurance that the suppliers have control of the process for product development. Systems engineering can broadly be defined as a discipline that seeks to ensure that all requirements for a system are satisfied throughout the life of the system by preserving their interrelationship. The key activities of systems engineering include requirements analysis, functional analysis/allocation, design synthesis and verification, and system analysis and control. The systems engineering process, when followed properly, will lead to higher quality products, lower cost products, and shorter development cycles. The System Engineering Capability Maturity Model (SE-CMM) will allow companies to measure their system engineering capability and continuously improve those capabilities. ISO 9000 and SE-CMM seem to have a similar objective, which is to document the organization's processes and certify to potential customers the capability of a supplier to control the processes that determine the quality of the product or services being produced. The remaining sections of this report examine the differences and similarities between ISO 9000 and SE-CMM and make recommendations for implementation.

  13. Event (error and near-miss) reporting and learning system for process improvement in radiation oncology.

    PubMed

    Mutic, Sasa; Brame, R Scott; Oddiraju, Swetha; Parikh, Parag; Westfall, Melisa A; Hopkins, Merilee L; Medina, Angel D; Danieley, Jonathan C; Michalski, Jeff M; El Naqa, Issam M; Low, Daniel A; Wu, Bin

    2010-09-01

    The value of near-miss and error reporting processes in many industries is well appreciated and typically can be supported with data that have been collected over time. While it is generally accepted that such processes are important in the radiation therapy (RT) setting, studies analyzing the effects of organized reporting and process improvement systems on operation and patient safety in individual clinics remain scarce. The purpose of this work is to report on the design and long-term use of an electronic reporting system in a RT department and compare it to the paper-based reporting system it replaced. A specifically designed web-based system was designed for reporting of individual events in RT and clinically implemented in 2007. An event was defined as any occurrence that could have, or had, resulted in a deviation in the delivery of patient care. The aim of the system was to support process improvement in patient care and safety. The reporting tool was designed so individual events could be quickly and easily reported without disrupting clinical work. This was very important because the system use was voluntary. The spectrum of reported deviations extended from minor workflow issues (e.g., scheduling) to errors in treatment delivery. Reports were categorized based on functional area, type, and severity of an event. The events were processed and analyzed by a formal process improvement group that used the data and the statistics collected through the web-based tool for guidance in reengineering clinical processes. The reporting trends for the first 24 months with the electronic system were compared to the events that were reported in the same clinic with a paper-based system over a seven-year period. The reporting system and the process improvement structure resulted in increased event reporting, improved event communication, and improved identification of clinical areas which needed process and safety improvements. The reported data were also useful for the evaluation of corrective measures and recognition of ineffective measures and efforts. The electronic system was relatively well accepted by personnel and resulted in minimal disruption of clinical work. Event reporting in the quarters with the fewest number of reported events, though voluntary, was almost four times greater than the most events reported in any one quarter with the paper-based system and remained consistent from the inception of the process through the date of this report. However, the acceptance was not universal, validating the need for improved education regarding reporting processes and systematic approaches to reporting culture development. Specially designed electronic event reporting systems in a radiotherapy setting can provide valuable data for process and patient safety improvement and are more effective reporting mechanisms than paper-based systems. Additional work is needed to develop methods that can more effectively utilize reported data for process improvement, including the development of standardized event taxonomy and a classification system for RT.

  14. Health-care process improvement decisions: a systems perspective.

    PubMed

    Walley, Paul; Silvester, Kate; Mountford, Shaun

    2006-01-01

    The paper seeks to investigate decision-making processes within hospital improvement activity, to understand how performance measurement systems influence decisions and potentially lead to unsuccessful or unsustainable process changes. A longitudinal study over a 33-month period investigates key events, decisions and outcomes at one medium-sized hospital in the UK. Process improvement events are monitored using process control methods and by direct observation. The authors took a systems perspective of the health-care processes, ensuring that the impacts of decisions across the health-care supply chain were appropriately interpreted. The research uncovers the ways in which measurement systems disguise failed decisions and encourage managers to take a low-risk approach of "symptomatic relief" when trying to improve performance metrics. This prevents many managers from trying higher risk, sustainable process improvement changes. The behaviour of the health-care system is not understood by many managers and this leads to poor analysis of problem situations. Measurement using time-series methodologies, such as statistical process control are vital for a better understanding of the systems impact of changes. Senior managers must also be aware of the behavioural influence of similar performance measurement systems that discourage sustainable improvement. There is a risk that such experiences will tarnish the reputation of performance management as a discipline. Recommends process control measures as a way of creating an organization memory of how decisions affect performance--something that is currently lacking.

  15. Comparison of Centralized-Manual, Centralized-Computerized, and Decentralized-Computerized Order and Management Information Models for the Turkish Air Force Logistics System.

    DTIC Science & Technology

    1986-09-01

    differentiation between the systems. This study will investigate an appropriate Order Processing and Management Information System (OP&MIS) to link base-level...methodology: 1. Reviewed the current order processing and information model of the TUAF Logistics System. (centralized-manual model) 2. Described the...RDS program’s order processing and information system. (centralized-computerized model) 3. Described the order irocessing and information system of

  16. [Discussion on research thinking of traditional Chinese medicine standardization system based on whole process quality control].

    PubMed

    Dong, Ling; Sun, Yu; Pei, Wen-Xuan; Dai, Jun-Dong; Wang, Zi-Yu; Pan, Meng; Chen, Jiang-Peng; Wang, Yun

    2017-12-01

    The concept of "Quality by design" indicates that good design for the whole life cycle of pharmaceutical production enables the drug to meet the expected quality requirements. Aiming at the existing problems of the traditional Chinese medicine (TCM) industry, the TCM standardization system was put forward in this paper from the national strategic level, under the guidance by the idea of quality control in international manufacturing industry and with considerations of TCM industry's own characteristics and development status. The connotation of this strategy was to establish five interrelated systems: multi-indicators system based on tri-indicators system, quality standard and specification system of TCM herbal materials and decoction pieces, quality traceability system, data monitoring system based on whole-process quality control, and whole-process quality management system of TCM, and achieve the whole process systematic and scientific study in TCM industry through "top-level design-implement in steps-system integration" workflow. This article analyzed the correlation between the quality standards of all links, established standard operating procedures of each link and whole process, and constructed a high standard overall quality management system for TCM industry chains, in order to provide a demonstration for the establishment of TCM whole-process quality control system and provide systematic reference and basis for standardization strategy in TCM industry. Copyright© by the Chinese Pharmaceutical Association.

  17. Natural Resource Information System. Volume 1: Overall description

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A prototype computer-based Natural Resource Information System was designed which could store, process, and display data of maximum usefulness to land management decision making. The system includes graphic input and display, the use of remote sensing as a data source, and it is useful at multiple management levels. A survey established current decision making processes and functions, information requirements, and data collection and processing procedures. The applications of remote sensing data and processing requirements were established. Processing software was constructed and a data base established using high-altitude imagery and map coverage of selected areas of SE Arizona. Finally a demonstration of system processing functions was conducted utilizing material from the data base.

  18. EOS MLS Science Data Processing System: A Description of Architecture and Capabilities

    NASA Technical Reports Server (NTRS)

    Cuddy, David T.; Echeverri, Mark D.; Wagner, Paul A.; Hanzel, Audrey T.; Fuller, Ryan A.

    2006-01-01

    This paper describes the architecture and capabilities of the Science Data Processing System (SDPS) for the EOS MLS. The SDPS consists of two major components--the Science Computing Facility and the Science Investigator-led Processing System. The Science Computing Facility provides the facilities for the EOS MLS Science Team to perform the functions of scientific algorithm development, processing software development, quality control of data products, and scientific analyses. The Science Investigator-led Processing System processes and reprocesses the science data for the entire mission and delivers the data products to the Science Computing Facility and to the Goddard Space Flight Center Earth Science Distributed Active Archive Center, which archives and distributes the standard science products.

  19. Efficient volatile metal removal from low rank coal in gasification, combustion, and processing systems and methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bland, Alan E.; Sellakumar, Kumar Muthusami; Newcomer, Jesse D.

    Efficient coal pre-processing systems (69) integrated with gasification, oxy-combustion, and power plant systems include a drying chamber (28), a volatile metal removal chamber (30), recirculated gases, including recycled carbon dioxide (21), nitrogen (6), and gaseous exhaust (60) for increasing the efficiencies and lowering emissions in various coal processing systems.

  20. Process for predicting structural performance of mechanical systems

    DOEpatents

    Gardner, David R.; Hendrickson, Bruce A.; Plimpton, Steven J.; Attaway, Stephen W.; Heinstein, Martin W.; Vaughan, Courtenay T.

    1998-01-01

    A process for predicting the structural performance of a mechanical system represents the mechanical system by a plurality of surface elements. The surface elements are grouped according to their location in the volume occupied by the mechanical system so that contacts between surface elements can be efficiently located. The process is well suited for efficient practice on multiprocessor computers.

  1. Application of advanced on-board processing concepts to future satellite communications systems

    NASA Technical Reports Server (NTRS)

    Katz, J. L.; Hoffman, M.; Kota, S. L.; Ruddy, J. M.; White, B. F.

    1979-01-01

    An initial definition of on-board processing requirements for an advanced satellite communications system to service domestic markets in the 1990's is presented. An exemplar system architecture with both RF on-board switching and demodulation/remodulation baseband processing was used to identify important issues related to system implementation, cost, and technology development.

  2. Information technology - a tool for development of the teaching process at the faculty of medicine, university of sarajevo.

    PubMed

    Masic, Izet; Begic, Edin

    2015-04-01

    Information Technologies, taking slow steps, have found its application in the teaching process of Faculty of Medicine, University of Sarajevo. Online availability of the teaching content is mainly intended for users of the Bologna process. The aim was to present the level of use of information technologies at the Faculty of Medicine, University of Sarajevo, comparing two systems, old system and the Bologna process, and to present new ways of improving the teaching process, using information technology. The study included the period from 2012 to 2014, and included 365 students from the old system and the Bologna Process. Study had prospective character. Students of the old system are older than students of the Bologna process. In both systems higher number of female students is significantly present. All students have their own computers, usually using the Office software package and web browsers. Visits of social networks were the most common reason for which they used computers. On question if they know to work with databases, 14.6% of students of the old system responded positively and 26.2% of students of the Bologna process answered the same. Students feel that working with databases is necessary to work in primary health care. On the question of the degree of computerization at the university, there were significant differences between the two systems (p <0.05). When asked about the possibility of using computers at school, there were no significant differences between the two systems. There has been progress of that opportunity from year to year. Students of Bologna process were more interested in the introduction of information technology, than students of old system. 68.7% of students of the Bologna process of generation 2013-2014, and 71.3% of generation 2014-2015, believed that the subject of Medical Informatics, the same or similar name, should be included in the new reform teaching process of the Faculty of Medicine, University of Sarajevo. Information technologies can help the development of the teaching process, and represent attractive and accessible tool in the process of modernization and progress.

  3. The automated system for technological process of spacecraft's waveguide paths soldering

    NASA Astrophysics Data System (ADS)

    Tynchenko, V. S.; Murygin, A. V.; Emilova, O. A.; Bocharov, A. N.; Laptenok, V. D.

    2016-11-01

    The paper solves the problem of automated process control of space vehicles waveguide paths soldering by means of induction heating. The peculiarities of the induction soldering process are analyzed and necessity of information-control system automation is identified. The developed automated system makes the control of the product heating process, by varying the power supplied to the inductor, on the basis of information about the soldering zone temperature, and stabilizing the temperature in a narrow range above the melting point of the solder but below the melting point of the waveguide. This allows the soldering process automating to improve the quality of the waveguides and eliminate burn-troughs. The article shows a block diagram of a software system consisting of five modules, and describes the main algorithm of its work. Also there is a description of the waveguide paths automated soldering system operation, for explaining the basic functions and limitations of the system. The developed software allows setting of the measurement equipment, setting and changing parameters of the soldering process, as well as view graphs of temperatures recorded by the system. There is shown the results of experimental studies that prove high quality of soldering process control and the system applicability to the tasks of automation.

  4. Paperless Procurement: The Impact of Advanced Automation

    DTIC Science & Technology

    1992-09-01

    System. POPS = Paperless Order Processing System; RADMIS = Research and Development Management Information System; SAACONS=Standard Army Automated... order processing system, which then updates the contractor’s production (or delivery) scheduling and contract accounting applications. In return, the...used by the DLA’s POPS. 3-5 into an EDI delivery order and pass it directly to the distributor’s or manufacturer’s order processing system. That

  5. Partitioning in parallel processing of production systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oflazer, K.

    1987-01-01

    This thesis presents research on certain issues related to parallel processing of production systems. It first presents a parallel production system interpreter that has been implemented on a four-processor multiprocessor. This parallel interpreter is based on Forgy's OPS5 interpreter and exploits production-level parallelism in production systems. Runs on the multiprocessor system indicate that it is possible to obtain speed-up of around 1.7 in the match computation for certain production systems when productions are split into three sets that are processed in parallel. The next issue addressed is that of partitioning a set of rules to processors in a parallel interpretermore » with production-level parallelism, and the extent of additional improvement in performance. The partitioning problem is formulated and an algorithm for approximate solutions is presented. The thesis next presents a parallel processing scheme for OPS5 production systems that allows some redundancy in the match computation. This redundancy enables the processing of a production to be divided into units of medium granularity each of which can be processed in parallel. Subsequently, a parallel processor architecture for implementing the parallel processing algorithm is presented.« less

  6. Transplant Image Processing Technology under Windows into the Platform Based on MiniGUI

    NASA Astrophysics Data System (ADS)

    Gan, Lan; Zhang, Xu; Lv, Wenya; Yu, Jia

    MFC has a large number of digital image processing-related API functions, object-oriented and class mechanisms which provides image processing technology strong support in Windows. But in embedded systems, image processing technology dues to the restrictions of hardware and software do not have the environment of MFC in Windows. Therefore, this paper draws on the experience of image processing technology of Windows and transplants it into MiniGUI embedded systems. The results show that MiniGUI/Embedded graphical user interface applications about image processing which used in embedded image processing system can be good results.

  7. ProcessGene-Connect: SOA Integration between Business Process Models and Enactment Transactions of Enterprise Software Systems

    NASA Astrophysics Data System (ADS)

    Wasser, Avi; Lincoln, Maya

    In recent years, both practitioners and applied researchers have become increasingly interested in methods for integrating business process models and enterprise software systems through the deployment of enabling middleware. Integrative BPM research has been mainly focusing on the conversion of workflow notations into enacted application procedures, and less effort has been invested in enhancing the connectivity between design level, non-workflow business process models and related enactment systems such as: ERP, SCM and CRM. This type of integration is useful at several stages of an IT system lifecycle, from design and implementation through change management, upgrades and rollout. The paper presents an integration method that utilizes SOA for connecting business process models with corresponding enterprise software systems. The method is then demonstrated through an Oracle E-Business Suite procurement process and its ERP transactions.

  8. System and process for production of magnesium metal and magnesium hydride from magnesium-containing salts and brines

    DOEpatents

    McGrail, Peter B.; Nune, Satish K.; Motkuri, Radha K.; Glezakou, Vassiliki-Alexandra; Koech, Phillip K.; Adint, Tyler T.; Fifield, Leonard S.; Fernandez, Carlos A.; Liu, Jian

    2016-11-22

    A system and process are disclosed for production of consolidated magnesium metal products and alloys with selected densities from magnesium-containing salts and feedstocks. The system and process employ a dialkyl magnesium compound that decomposes to produce the Mg metal product. Energy requirements and production costs are lower than for conventional processing.

  9. An interfaces approach to TES ground data system processing design with the Science Investigator-led Processing System (SIPS)

    NASA Technical Reports Server (NTRS)

    Kurian, R.; Grifin, A.

    2002-01-01

    Developing production-quality software to process the large volumes of scientific data is the responsibility of the TES Ground Data System, which is being developed at the Jet Propulsion Laboratory together with support contractor Raytheon/ITSS. The large data volume and processing requirements of the TES pose significant challenges to the design.

  10. Grinding Wheel System

    DOEpatents

    Malkin, Stephen; Gao, Robert; Guo, Changsheng; Varghese, Biju; Pathare, Sumukh

    2003-08-05

    A grinding wheel system includes a grinding wheel with at least one embedded sensor. The system also includes an adapter disk containing electronics that process signals produced by each embedded sensor and that transmits sensor information to a data processing platform for further processing of the transmitted information.

  11. Grinding Wheel System

    DOEpatents

    Malkin, Stephen; Gao, Robert; Guo, Changsheng; Varghese, Biju; Pathare, Sumukh

    2006-01-10

    A grinding wheel system includes a grinding wheel with at least one embedded sensor. The system also includes an adapter disk containing electronics that process signals produced by each embedded sensor and that transmits sensor information to a data processing platform for further processing of the transmitted information.

  12. 76 FR 16277 - System Restoration Reliability Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... system restoration process. The Commission also approves the NERC's proposal to retire four existing EOP... prepare personnel to enable effective coordination of the system restoration process. The Commission also..., through the Reliability Standard development process, a modification to EOP-005-1 that identifies time...

  13. Reconceptualizing Learning as a Dynamical System.

    ERIC Educational Resources Information Center

    Ennis, Catherine D.

    1992-01-01

    Dynamical systems theory can increase our understanding of the constantly evolving learning process. Current research using experimental and interpretive paradigms focuses on describing the attractors and constraints stabilizing the educational process. Dynamical systems theory focuses attention on critical junctures in the learning process as…

  14. Information Processing Capacity of Dynamical Systems

    NASA Astrophysics Data System (ADS)

    Dambre, Joni; Verstraeten, David; Schrauwen, Benjamin; Massar, Serge

    2012-07-01

    Many dynamical systems, both natural and artificial, are stimulated by time dependent external signals, somehow processing the information contained therein. We demonstrate how to quantify the different modes in which information can be processed by such systems and combine them to define the computational capacity of a dynamical system. This is bounded by the number of linearly independent state variables of the dynamical system, equaling it if the system obeys the fading memory condition. It can be interpreted as the total number of linearly independent functions of its stimuli the system can compute. Our theory combines concepts from machine learning (reservoir computing), system modeling, stochastic processes, and functional analysis. We illustrate our theory by numerical simulations for the logistic map, a recurrent neural network, and a two-dimensional reaction diffusion system, uncovering universal trade-offs between the non-linearity of the computation and the system's short-term memory.

  15. Information Processing Capacity of Dynamical Systems

    PubMed Central

    Dambre, Joni; Verstraeten, David; Schrauwen, Benjamin; Massar, Serge

    2012-01-01

    Many dynamical systems, both natural and artificial, are stimulated by time dependent external signals, somehow processing the information contained therein. We demonstrate how to quantify the different modes in which information can be processed by such systems and combine them to define the computational capacity of a dynamical system. This is bounded by the number of linearly independent state variables of the dynamical system, equaling it if the system obeys the fading memory condition. It can be interpreted as the total number of linearly independent functions of its stimuli the system can compute. Our theory combines concepts from machine learning (reservoir computing), system modeling, stochastic processes, and functional analysis. We illustrate our theory by numerical simulations for the logistic map, a recurrent neural network, and a two-dimensional reaction diffusion system, uncovering universal trade-offs between the non-linearity of the computation and the system's short-term memory. PMID:22816038

  16. Advanced Manufacturing Systems in Food Processing and Packaging Industry

    NASA Astrophysics Data System (ADS)

    Shafie Sani, Mohd; Aziz, Faieza Abdul

    2013-06-01

    In this paper, several advanced manufacturing systems in food processing and packaging industry are reviewed, including: biodegradable smart packaging and Nano composites, advanced automation control system consists of fieldbus technology, distributed control system and food safety inspection features. The main purpose of current technology in food processing and packaging industry is discussed due to major concern on efficiency of the plant process, productivity, quality, as well as safety. These application were chosen because they are robust, flexible, reconfigurable, preserve the quality of the food, and efficient.

  17. The application of digital techniques to the analysis of metallurgical experiments

    NASA Technical Reports Server (NTRS)

    Rathz, T. J.

    1977-01-01

    The application of a specific digital computer system (known as the Image Data Processing System) to the analysis of three NASA-sponsored metallurgical experiments is discussed in some detail. The basic hardware and software components of the Image Data Processing System are presented. Many figures are presented in the discussion of each experimental analysis in an attempt to show the accuracy and speed that the Image Data Processing System affords in analyzing photographic images dealing with metallurgy, and in particular with material processing.

  18. Architecture Of High Speed Image Processing System

    NASA Astrophysics Data System (ADS)

    Konishi, Toshio; Hayashi, Hiroshi; Ohki, Tohru

    1988-01-01

    One of architectures for a high speed image processing system which corresponds to a new algorithm for a shape understanding is proposed. And the hardware system which is based on the archtecture was developed. Consideration points of the architecture are mainly that using processors should match with the processing sequence of the target image and that the developed system should be used practically in an industry. As the result, it was possible to perform each processing at a speed of 80 nano-seconds a pixel.

  19. A Process Management System for Networked Manufacturing

    NASA Astrophysics Data System (ADS)

    Liu, Tingting; Wang, Huifen; Liu, Linyan

    With the development of computer, communication and network, networked manufacturing has become one of the main manufacturing paradigms in the 21st century. Under the networked manufacturing environment, there exist a large number of cooperative tasks susceptible to alterations, conflicts caused by resources and problems of cost and quality. This increases the complexity of administration. Process management is a technology used to design, enact, control, and analyze networked manufacturing processes. It supports efficient execution, effective management, conflict resolution, cost containment and quality control. In this paper we propose an integrated process management system for networked manufacturing. Requirements of process management are analyzed and architecture of the system is presented. And a process model considering process cost and quality is developed. Finally a case study is provided to explain how the system runs efficiently.

  20. IMAGES: An interactive image processing system

    NASA Technical Reports Server (NTRS)

    Jensen, J. R.

    1981-01-01

    The IMAGES interactive image processing system was created specifically for undergraduate remote sensing education in geography. The system is interactive, relatively inexpensive to operate, almost hardware independent, and responsive to numerous users at one time in a time-sharing mode. Most important, it provides a medium whereby theoretical remote sensing principles discussed in lecture may be reinforced in laboratory as students perform computer-assisted image processing. In addition to its use in academic and short course environments, the system has also been used extensively to conduct basic image processing research. The flow of information through the system is discussed including an overview of the programs.

  1. Lateral position detection and control for friction stir systems

    DOEpatents

    Fleming, Paul; Lammlein, David; Cook, George E.; Wilkes, Don Mitchell; Strauss, Alvin M.; Delapp, David; Hartman, Daniel A.

    2010-12-14

    A friction stir system for processing at least a first workpiece includes a spindle actuator coupled to a rotary tool comprising a rotating member for contacting and processing the first workpiece. A detection system is provided for obtaining information related to a lateral alignment of the rotating member. The detection system comprises at least one sensor for measuring a force experienced by the rotary tool or a parameter related to the force experienced by the rotary tool during processing, wherein the sensor provides sensor signals. A signal processing system is coupled to receive and analyze the sensor signals and determine a lateral alignment of the rotating member relative to a selected lateral position, a selected path, or a direction to decrease a lateral distance relative to the selected lateral position or selected path. In one embodiment, the friction stir system can be embodied as a closed loop tracking system, such as a robot-based tracked friction stir welding (FSW) or friction stir processing (FSP) system.

  2. SPECIAL ISSUE ON OPTICAL PROCESSING OF INFORMATION: Optical signal-processing systems based on anisotropic media

    NASA Astrophysics Data System (ADS)

    Kiyashko, B. V.

    1995-10-01

    Partially coherent optical systems for signal processing are considered. The transfer functions are formed in these systems by interference of polarised light transmitted by an anisotropic medium. It is shown that such systems can perform various integral transformations of both optical and electric signals, in particular, two-dimensional Fourier and Fresnel transformations, as well as spectral analysis of weak light sources. It is demonstrated that such systems have the highest luminosity and vibration immunity among the systems with interference formation of transfer functions. An experimental investigation is reported of the application of these systems in the processing of signals from a linear hydroacoustic antenna array, and in measurements of the optical spectrum and of the intrinsic noise.

  3. Integrated Main Propulsion System Performance Reconstruction Process/Models

    NASA Technical Reports Server (NTRS)

    Lopez, Eduardo; Elliott, Katie; Snell, Steven; Evans, Michael

    2013-01-01

    The Integrated Main Propulsion System (MPS) Performance Reconstruction process provides the MPS post-flight data files needed for postflight reporting to the project integration management and key customers to verify flight performance. This process/model was used as the baseline for the currently ongoing Space Launch System (SLS) work. The process utilizes several methodologies, including multiple software programs, to model integrated propulsion system performance through space shuttle ascent. It is used to evaluate integrated propulsion systems, including propellant tanks, feed systems, rocket engine, and pressurization systems performance throughout ascent based on flight pressure and temperature data. The latest revision incorporates new methods based on main engine power balance model updates to model higher mixture ratio operation at lower engine power levels.

  4. Development of process control capability through the Browns Ferry Integrated Computer System using Reactor Water Clanup System as an example. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, J.; Mowrey, J.

    1995-12-01

    This report describes the design, development and testing of process controls for selected system operations in the Browns Ferry Nuclear Plant (BFNP) Reactor Water Cleanup System (RWCU) using a Computer Simulation Platform which simulates the RWCU System and the BFNP Integrated Computer System (ICS). This system was designed to demonstrate the feasibility of the soft control (video touch screen) of nuclear plant systems through an operator console. The BFNP Integrated Computer System, which has recently. been installed at BFNP Unit 2, was simulated to allow for operator control functions of the modeled RWCU system. The BFNP Unit 2 RWCU systemmore » was simulated using the RELAP5 Thermal/Hydraulic Simulation Model, which provided the steady-state and transient RWCU process variables and simulated the response of the system to control system inputs. Descriptions of the hardware and software developed are also included in this report. The testing and acceptance program and results are also detailed in this report. A discussion of potential installation of an actual RWCU process control system in BFNP Unit 2 is included. Finally, this report contains a section on industry issues associated with installation of process control systems in nuclear power plants.« less

  5. Workflow management systems in radiology

    NASA Astrophysics Data System (ADS)

    Wendler, Thomas; Meetz, Kirsten; Schmidt, Joachim

    1998-07-01

    In a situation of shrinking health care budgets, increasing cost pressure and growing demands to increase the efficiency and the quality of medical services, health care enterprises are forced to optimize or complete re-design their processes. Although information technology is agreed to potentially contribute to cost reduction and efficiency improvement, the real success factors are the re-definition and automation of processes: Business Process Re-engineering and Workflow Management. In this paper we discuss architectures for the use of workflow management systems in radiology. We propose to move forward from information systems in radiology (RIS, PACS) to Radiology Management Systems, in which workflow functionality (process definitions and process automation) is implemented through autonomous workflow management systems (WfMS). In a workflow oriented architecture, an autonomous workflow enactment service communicates with workflow client applications via standardized interfaces. In this paper, we discuss the need for and the benefits of such an approach. The separation of workflow management system and application systems is emphasized, and the consequences that arise for the architecture of workflow oriented information systems. This includes an appropriate workflow terminology, and the definition of standard interfaces for workflow aware application systems. Workflow studies in various institutions have shown that most of the processes in radiology are well structured and suited for a workflow management approach. Numerous commercially available Workflow Management Systems (WfMS) were investigated, and some of them, which are process- oriented and application independent, appear suitable for use in radiology.

  6. An architecture for heuristic control of real-time processes

    NASA Technical Reports Server (NTRS)

    Raulefs, P.; Thorndyke, P. W.

    1987-01-01

    Abstract Process management combines complementary approaches of heuristic reasoning and analytical process control. Management of a continuous process requires monitoring the environment and the controlled system, assessing the ongoing situation, developing and revising planned actions, and controlling the execution of the actions. For knowledge-intensive domains, process management entails the potentially time-stressed cooperation among a variety of expert systems. By redesigning a blackboard control architecture in an object-oriented framework, researchers obtain an approach to process management that considerably extends blackboard control mechanisms and overcomes limitations of blackboard systems.

  7. Two improved coherent optical feedback systems for optical information processing

    NASA Technical Reports Server (NTRS)

    Lee, S. H.; Bartholomew, B.; Cederquist, J.

    1976-01-01

    Coherent optical feedback systems are Fabry-Perot interferometers modified to perform optical information processing. Two new systems based on plane parallel and confocal Fabry-Perot interferometers are introduced. The plane parallel system can be used for contrast control, intensity level selection, and image thresholding. The confocal system can be used for image restoration and solving partial differential equations. These devices are simpler and less expensive than previous systems. Experimental results are presented to demonstrate their potential for optical information processing.

  8. Low-cost Landsat digital processing system for state and local information systems

    NASA Technical Reports Server (NTRS)

    Hooper, N. J.; Spann, G. W.; Faust, N. L.; Paludan, C. T. N.

    1979-01-01

    The paper details a minicomputer-based system which is well within the budget of many state, regional, and local agencies that previously could not afford digital processing capability. In order to achieve this goal a workable small-scale Landsat system is examined to provide low-cost automated processing. It is anticipated that the alternative systems will be based on a single minicomputer, but that the peripherals will vary depending on the capability emphasized in a particular system.

  9. Graphical Language for Data Processing

    NASA Technical Reports Server (NTRS)

    Alphonso, Keith

    2011-01-01

    A graphical language for processing data allows processing elements to be connected with virtual wires that represent data flows between processing modules. The processing of complex data, such as lidar data, requires many different algorithms to be applied. The purpose of this innovation is to automate the processing of complex data, such as LIDAR, without the need for complex scripting and programming languages. The system consists of a set of user-interface components that allow the user to drag and drop various algorithmic and processing components onto a process graph. By working graphically, the user can completely visualize the process flow and create complex diagrams. This innovation supports the nesting of graphs, such that a graph can be included in another graph as a single step for processing. In addition to the user interface components, the system includes a set of .NET classes that represent the graph internally. These classes provide the internal system representation of the graphical user interface. The system includes a graph execution component that reads the internal representation of the graph (as described above) and executes that graph. The execution of the graph follows the interpreted model of execution in that each node is traversed and executed from the original internal representation. In addition, there are components that allow external code elements, such as algorithms, to be easily integrated into the system, thus making the system infinitely expandable.

  10. Radar signal pre-processing to suppress surface bounce and multipath

    DOEpatents

    Paglieroni, David W; Mast, Jeffrey E; Beer, N. Reginald

    2013-12-31

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes that return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

  11. Analysis of exergy efficiency of a super-critical compressed carbon dioxide energy-storage system based on the orthogonal method.

    PubMed

    He, Qing; Hao, Yinping; Liu, Hui; Liu, Wenyi

    2018-01-01

    Super-critical carbon dioxide energy-storage (SC-CCES) technology is a new type of gas energy-storage technology. This paper used orthogonal method and variance analysis to make significant analysis on the factors which would affect the thermodynamics characteristics of the SC-CCES system and obtained the significant factors and interactions in the energy-storage process, the energy-release process and the whole energy-storage system. Results have shown that the interactions in the components have little influence on the energy-storage process, the energy-release process and the whole energy-storage process of the SC-CCES system, the significant factors are mainly on the characteristics of the system component itself, which will provide reference for the optimization of the thermal properties of the energy-storage system.

  12. Spatially assisted down-track median filter for GPR image post-processing

    DOEpatents

    Paglieroni, David W; Beer, N Reginald

    2014-10-07

    A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

  13. A model system for targeted drug release triggered by biomolecular signals logically processed through enzyme logic networks.

    PubMed

    Mailloux, Shay; Halámek, Jan; Katz, Evgeny

    2014-03-07

    A new Sense-and-Act system was realized by the integration of a biocomputing system, performing analytical processes, with a signal-responsive electrode. A drug-mimicking release process was triggered by biomolecular signals processed by different logic networks, including three concatenated AND logic gates or a 3-input OR logic gate. Biocatalytically produced NADH, controlled by various combinations of input signals, was used to activate the electrochemical system. A biocatalytic electrode associated with signal-processing "biocomputing" systems was electrically connected to another electrode coated with a polymer film, which was dissolved upon the formation of negative potential releasing entrapped drug-mimicking species, an enzyme-antibody conjugate, operating as a model for targeted immune-delivery and consequent "prodrug" activation. The system offers great versatility for future applications in controlled drug release and personalized medicine.

  14. DMD: a digital light processing application to projection displays

    NASA Astrophysics Data System (ADS)

    Feather, Gary A.

    1989-01-01

    Summary Revolutionary technologies achieve rapid product and subsequent business diffusion only when the in- ventors focus on technology application, maturation, and proliferation. A revolutionary technology is emerg- ing with micro-electromechanical systems (MEMS). MEMS are being developed by leveraging mature semi- conductor processing coupled with mechanical systems into complete, integrated, useful systems. The digital micromirror device (DMD), a Texas Instruments invented MEMS, has focused on its application to projec- tion displays. The DMD has demonstrated its application as a digital light processor, processing and produc- ing compelling computer and video projection displays. This tutorial discusses requirements in the projection display market and the potential solutions offered by this digital light processing system. The seminar in- cludes an evaluation of the market, system needs, design, fabrication, application, and performance results of a system using digital light processing solutions.

  15. Analysis of exergy efficiency of a super-critical compressed carbon dioxide energy-storage system based on the orthogonal method

    PubMed Central

    He, Qing; Liu, Hui; Liu, Wenyi

    2018-01-01

    Super-critical carbon dioxide energy-storage (SC-CCES) technology is a new type of gas energy-storage technology. This paper used orthogonal method and variance analysis to make significant analysis on the factors which would affect the thermodynamics characteristics of the SC-CCES system and obtained the significant factors and interactions in the energy-storage process, the energy-release process and the whole energy-storage system. Results have shown that the interactions in the components have little influence on the energy-storage process, the energy-release process and the whole energy-storage process of the SC-CCES system, the significant factors are mainly on the characteristics of the system component itself, which will provide reference for the optimization of the thermal properties of the energy-storage system. PMID:29634742

  16. Fabrication Process for Large Size Mold and Alignment Method for Nanoimprint System

    NASA Astrophysics Data System (ADS)

    Ishibashi, Kentaro; Kokubo, Mitsunori; Goto, Hiroshi; Mizuno, Jun; Shoji, Shuichi

    Nanoimprint technology is considered one of the mass production methods of the display for cellular phone or notebook computer, with Anti-Reflection Structures (ARS) pattern and so on. In this case, the large size mold with nanometer order pattern is very important. Then, we describe the fabrication process for large size mold, and the alignment method for UV nanoimprint system. We developed the original mold fabrication process using nanoimprint method and etching techniques. In 66 × 45 mm2 area, 200nm period seamless patterns were formed using this process. And, we constructed original alignment system that consists of the CCD-camera system, X-Y-θ table, method of moiré fringe, and image processing system, because the accuracy of pattern connection depends on the alignment method. This alignment system accuracy was within 20nm.

  17. Intelligent Work Process Engineering System

    NASA Technical Reports Server (NTRS)

    Williams, Kent E.

    2003-01-01

    Optimizing performance on work activities and processes requires metrics of performance for management to monitor and analyze in order to support further improvements in efficiency, effectiveness, safety, reliability and cost. Information systems are therefore required to assist management in making timely, informed decisions regarding these work processes and activities. Currently information systems regarding Space Shuttle maintenance and servicing do not exist to make such timely decisions. The work to be presented details a system which incorporates various automated and intelligent processes and analysis tools to capture organize and analyze work process related data, to make the necessary decisions to meet KSC organizational goals. The advantages and disadvantages of design alternatives to the development of such a system will be discussed including technologies, which would need to bedesigned, prototyped and evaluated.

  18. WASTE TREATMENT BUILDING SYSTEM DESCRIPTION DOCUMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    F. Habashi

    2000-06-22

    The Waste Treatment Building System provides the space, layout, structures, and embedded subsystems that support the processing of low-level liquid and solid radioactive waste generated within the Monitored Geologic Repository (MGR). The activities conducted in the Waste Treatment Building include sorting, volume reduction, and packaging of dry waste, and collecting, processing, solidification, and packaging of liquid waste. The Waste Treatment Building System is located on the surface within the protected area of the MGR. The Waste Treatment Building System helps maintain a suitable environment for the waste processing and protects the systems within the Waste Treatment Building (WTB) from mostmore » of the natural and induced environments. The WTB also confines contaminants and provides radiological protection to personnel. In addition to the waste processing operations, the Waste Treatment Building System provides space and layout for staging of packaged waste for shipment, industrial and radiological safety systems, control and monitoring of operations, safeguards and security systems, and fire protection, ventilation and utilities systems. The Waste Treatment Building System also provides the required space and layout for maintenance activities, tool storage, and administrative facilities. The Waste Treatment Building System integrates waste processing systems within its protective structure to support the throughput rates established for the MGR. The Waste Treatment Building System also provides shielding, layout, and other design features to help limit personnel radiation exposures to levels which are as low as is reasonably achievable (ALARA). The Waste Treatment Building System interfaces with the Site Generated Radiological Waste Handling System, and with other MGR systems that support the waste processing operations. The Waste Treatment Building System interfaces with the General Site Transportation System, Site Communications System, Site Water System, MGR Site Layout, Safeguards and Security System, Site Radiological Monitoring System, Site Electrical Power System, Site Compressed Air System, and Waste Treatment Building Ventilation System.« less

  19. Dynamic Modeling of Process Technologies for Closed-Loop Water Recovery Systems

    NASA Technical Reports Server (NTRS)

    Allada, Rama Kumar; Lange, Kevin; Anderson, Molly

    2011-01-01

    Detailed chemical process simulations are a useful tool in designing and optimizing complex systems and architectures for human life support. Dynamic and steady-state models of these systems help contrast the interactions of various operating parameters and hardware designs, which become extremely useful in trade-study analyses. NASA s Exploration Life Support technology development project recently made use of such models to compliment a series of tests on different waste water distillation systems. This paper presents dynamic simulations of chemical process for primary processor technologies including: the Cascade Distillation System (CDS), the Vapor Compression Distillation (VCD) system, the Wiped-Film Rotating Disk (WFRD), and post-distillation water polishing processes such as the Volatiles Removal Assembly (VRA) that were developed using the Aspen Custom Modeler and Aspen Plus process simulation tools. The results expand upon previous work for water recovery technology models and emphasize dynamic process modeling and results. The paper discusses system design, modeling details, and model results for each technology and presents some comparisons between the model results and available test data. Following these initial comparisons, some general conclusions and forward work are discussed.

  20. In-situ materials processing systems and bioregenerative life support systems interrelationships

    NASA Technical Reports Server (NTRS)

    Mignon, George V.; Frye, Robert J.

    1992-01-01

    The synergy and linkages between bioregenerative life support systems and the materials produced by in-situ materials processing systems was investigated. Such systems produce a broad spectrum of byproducts such as oxygen, hydrogen, processed soil material, ceramics, refractory, and other materials. Some of these materials may be utilized by bioregenerative systems either directly or with minor modifications. The main focus of this project was to investigate how these materials can be utilized to assist a bioregenerative life support system. Clearly the need to provide a sustainable bioregenerative life support system for long term human habitation of space is significant.

Top