Sample records for sponsored interlaboratory testing

  1. Bayesian Local Contamination Models for Multivariate Outliers

    PubMed Central

    Page, Garritt L.; Dunson, David B.

    2013-01-01

    In studies where data are generated from multiple locations or sources it is common for there to exist observations that are quite unlike the majority. Motivated by the application of establishing a reference value in an inter-laboratory setting when outlying labs are present, we propose a local contamination model that is able to accommodate unusual multivariate realizations in a flexible way. The proposed method models the process level of a hierarchical model using a mixture with a parametric component and a possibly nonparametric contamination. Much of the flexibility in the methodology is achieved by allowing varying random subsets of the elements in the lab-specific mean vectors to be allocated to the contamination component. Computational methods are developed and the methodology is compared to three other possible approaches using a simulation study. We apply the proposed method to a NIST/NOAA sponsored inter-laboratory study which motivated the methodological development. PMID:24363465

  2. Department of Homeland Security (DHS) Proficiency Testing on Small-Scale Safety and Thermal Testing of Improvised Explosives

    NASA Astrophysics Data System (ADS)

    Reynolds, John; Sandstrom, Mary; Brown, Geoffrey; Warner, Kirstin; Phillips, Jason; Shelley, Timothy; Reyes, Jose; Hsu, Peter

    2013-06-01

    One of the first steps in establishing safe handling procedures for explosives is small-scale safety and thermal (SSST) testing. To better understand the response of improvised materials or HMEs to SSST testing, 18 HME materials were compared to 3 standard military explosives in a proficiency-type round robin study among five laboratories--2 DoD and 3 DOE--sponsored by DHS. The testing matrix has been designed to address problems encountered with improvised materials--powder mixtures, liquid suspensions, partially wetted solids, immiscible liquids, and reactive materials. Over 30 issues have been identified that indicate standard test methods may require modification when applied to HMEs to derive accurate sensitivity assessments needed for development safe handling and storage practices. This presentation will discuss experimental difficulties encountered when testing these problematic samples, show inter-laboratory testing results, show some statistical interpretation of the results, and highlight some of the testing issues. Some of the work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. LLNL-ABS-617519 (721812).

  3. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    NASA Technical Reports Server (NTRS)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  4. INTERLABORATORY COMPARISON OF A REDUCED VOLUME MARINE SEDIMENT TOXICITY TEST METHOD USING AMPHIPOD AMPELISCA ABDITA

    EPA Science Inventory

    The U.S. Environmental Protection Agency has standardized methods for performing acute marine amphipod sediment toxicity tests. A test design reducing sediment volume from 200 to 50 ml and overlying water from 600 to 150 ml was recently proposed. An interlaboratory comparison wa...

  5. An interlaboratory comparison of sediment elutriate preparation and toxicity test methods

    EPA Science Inventory

    Elutriate bioassays are among numerous methods that exist for assessing the potential toxicity of sediments in aquatic systems. In this study, interlaboratory results were compared from 96-hour Ceriodaphnia dubia and Pimephales promelas static-renewal acute toxicity tests conduct...

  6. Manganese recycling in the United States in 1998

    USGS Publications Warehouse

    Jones, Thomas S.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  7. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species

    EPA Science Inventory

    The authors developed a toxicity database for unionid mussels to examine the extent of intra- and interlaboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the 2 life stages; and the variation in se...

  8. Inter-laboratory validation of bioaccessibility testing for metals.

    PubMed

    Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R

    2014-10-01

    Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species - SETAC Abstract

    EPA Science Inventory

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitiv...

  10. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in April 2001

    USGS Publications Warehouse

    Woodworth, M.T.; Connor, B.F.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-165 (trace constituents), M-158 (major constituents), N-69 (nutrient constituents), N-70 (nutrient constituents), P-36 (low ionic-strength constituents), and Hg-32 (mercury) -- that were distributed in April 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 73 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  11. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2002

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-171 (trace constituents), M-164 (major constituents), N-75 (nutrient constituents), N-76 (nutrient constituents), P-39 (low ionic-strength constituents), and Hg-35 (mercury) -- that were distributed in September 2002 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 102 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  12. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in September 2001

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2002-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-167 (trace constituents), M-160 (major constituents), N-71 (nutrient constituents), N-72 (nutrient constituents), P-37 (low ionic-strength constituents), and Hg-33 (mercury) -- that were distributed in September 2001 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 98 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  13. Results of the U.S. Geological Survey's Analytical Evaluation Program for Standard Reference Samples Distributed in March 2000

    USGS Publications Warehouse

    Farrar, Jerry W.; Copen, Ashley M.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-161 (trace constituents), M-154 (major constituents), N-65 (nutrient constituents), N-66 nutrient constituents), P-34 (low ionic strength constituents), and Hg-30 (mercury) -- that were distributed in March 2000 to 144 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 132 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  14. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 1999

    USGS Publications Warehouse

    Farrar, T.W.

    2000-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-159 (trace constituents), M-152 (major constituents), N-63 (nutrient constituents), N-64 (nutrient constituents), P-33 (low ionic strength constituents), and Hg-29 (mercury) -- that were distributed in October 1999 to 149 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 131 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  15. Results of the U.S. Geological Survey's analytical evaluation program for standard reference samples distributed in March 2003

    USGS Publications Warehouse

    Woodworth, Mark T.; Connor, Brooke F.

    2003-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-173 (trace constituents), M-166 (major constituents), N-77 (nutrient constituents), N-78 (nutrient constituents), P-40 (low ionic-strength constituents), and Hg-36 (mercury) -- that were distributed in March 2003 to laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 110 laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  16. Results of the U. S. Geological Survey's analytical evaluation program for standard reference samples distributed in October 2000

    USGS Publications Warehouse

    Connor, B.F.; Currier, J.P.; Woodworth, M.T.

    2001-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for six standard reference samples -- T-163 (trace constituents), M-156 (major constituents), N-67 (nutrient constituents), N-68 (nutrient constituents), P-35 (low ionic strength constituents), and Hg-31 (mercury) -- that were distributed in October 2000 to 126 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 122 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  17. Intra- and interlaboratory variability in acute toxicity tests with glochidia and juveniles of freshwater mussels (Unionidae)

    USGS Publications Warehouse

    Wang, N.; Augspurger, T.; Barnhart, M.C.; Bidwell, Joseph R.; Cope, W.G.; Dwyer, F.J.; Geis, S.; Greer, I.E.; Ingersoll, C.G.; Kane, C.M.; May, T.W.; Neves, R.J.; Newton, T.J.; Roberts, A.D.; Whites, D.W.

    2007-01-01

    The present study evaluated the performance and variability in acute toxicity tests with glochidia and newly transformed juvenile mussels using the standard methods outlined in American Society for Testing and Materials (ASTM). Multiple 48-h toxicity tests with glochidia and 96-h tests with juvenile mussels were conducted within a single laboratory and among five laboratories. All tests met the test acceptability requirements (e.g., ???90% control survival). Intralaboratory tests were conducted over two consecutive mussel-spawning seasons with mucket (Actinonaias ligamentina) or fatmucket (Lampsilis siliquoidea) using copper, ammonia, or chlorine as a toxicant. For the glochidia of both species, the variability of intralaboratory median effective concentrations (EC50s) for the three toxicants, expressed as the coefficient of variation (CV), ranged from 14 to 27% in 24-h exposures and from 13 to 36% in 48-h exposures. The intralaboratory CV of copper EC50s for juvenile fatmucket was 24% in 48-h exposures and 13% in 96-h exposures. Interlaboratory tests were conducted with fatmucket glochidia and juveniles by five laboratories using copper as a toxicant. The interlaboratory CV of copper EC50s for glochidia was 13% in 24-h exposures and 24% in 48-h exposures, and the interlaboratory CV for juveniles was 22% in 48-h exposures and 42% in 96-h exposures. The high completion success and the overall low variability in test results indicate that the test methods have acceptable precision and can be performed routinely. ?? 2007 SETAC.

  18. Interlaboratory tests for low-level radioactivity measurements in France

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Despres, M.

    In the framework of French national metrological coordination, the Laboratoire de Metrologie des Rayonnements Ionisants (LMRI) organizes every year an interlaboratory test program. The participation in these programs is on a voluntary basis and the results are presented in a nameless way. These tests concern radioactivity, neutron and dosimetry measurements. In this paper, a review of interlaboratory tests for low-level radioactivity measurements proposed by LMRI is given from 1975 to 1986. Every year, three types of tests are proposed: activity tests, multigamma tests, radioanalysis tests. For the last ten years, the number of results has been respectively 90 for activitymore » tests, 570 for multigamma tests and 400 for radioanalysis tests. The user's interest has increased, while the quality of results has improved. The deviations from LMRI's reference values are less than 3% for a restricted number of laboratories, and range between 3 and 10% for the majority of the others. The most urgent tests are for mixtures of {sup 90}Sr and activation and fission products in various matrices such as milk, grass, cereals, and sediments. 16 refs., 3 figs., 3 tabs.« less

  19. Interlaboratory and between-specimen comparisons of diagnostic tests for leptospirosis in sheep and cattle.

    PubMed

    Fang, Fang; Collins-Emerson, Julie M; Heuer, Cord; Hill, Fraser I; Tisdall, David J; Wilson, Peter R; Benschop, Jackie

    2014-11-01

    A study was performed to investigate interlaboratory test agreement between a research and a commercial veterinary diagnostic laboratory on blood and urine samples, and to investigate test agreement between blood, urine, and kidney samples (research laboratory) for leptospirosis diagnosis. Samples were sourced from 399 sheep and 146 beef cattle from a local abattoir. Interlaboratory agreement for real-time quantitative polymerase chain reaction (qPCR) results on urine samples was almost perfect (kappa = 0.90), despite the use of different amplification targets (DNA gyrase subunit B gene vs. 16s ribosomal RNA gene), chemistries (SYTO9 vs. TaqMan probe), and pre-PCR processing. Interlaboratory agreement for microscopic agglutination test (MAT) positivity was almost perfect (kappa = 0.93) for Leptospira borgpetersenii serovar Hardjo subtype Hardjobovis (Hardjobovis) but moderate (kappa = 0.53) for Leptospira interrogans serovar Pomona (Pomona). Among animals that had different titers recorded, higher Hardjobovis and lower Pomona titers were reported by the commercial laboratory than by the research laboratory (P < 0.005). These interlaboratory comparisons can assist researchers and diagnosticians in interpreting the sometimes discrepant test results. Within the research laboratory, the comparison of qPCR results on urine and kidney showed almost perfect agreement (kappa = 0.84), suggesting that the qPCR on these 2 specimens can be used interchangeably. The agreement between MAT positivity and urine and kidney qPCR results was fair (kappa = 0.32 and kappa = 0.33, respectively). However, the prevalence ratio of urine and kidney qPCR positivity in Hardjobovis-seropositive versus Hardjobovis-seronegative sheep indicated that Hardjobovis seropositivity found in sheep may be able to predict shedding or renal carriage. © 2014 The Author(s).

  20. Argon Intercalibration Pipette System (APIS): Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Deino, A. L.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.

    2014-12-01

    40Ar/39Ar age inter-calibration experiments, conducted as part of the US NSF sponsored EARTHTIME initiative, (http://www.earth-time.org), using two of the most commonly used 40Ar/39Ar mineral standards, Fish Canyon (FC, ~28.2 Ma) and Alder Creek (AC, ~1.2 Ma) sanidines, have revealed significant inter-laboratory inconsistencies. The reported ages for the AC sanidines range from 1.173 to 1.200 Ma (FC 28.02) (±~2%), ~4 times greater than the reported precision. These experiments have caused the 40Ar/39Ar community to scrutinize procedures and several informal lab intercalibrations have been conducted among different labs. This exercise is leading to better agreement, but discrepancies remain that need to be addressed. In an effort to isolate the cause(s) of these inconsistencies, two Argon Inter-calibration Pipette System (APIS) were designed and constructed. Each consists of three gas canisters; one contains atmospheric Ar, while the other two contain artificial gas mixtures with 40Ar/39Ar ratios similar to those of FC and AC. Each canister has 4x10-10 moles of 40Ar, is equipped with 0.1, 0.2 and 0.4 cc pipettes, and can deliver gas volumes from 0.1-0.7 cc. All volumes were determined manometrically to 0.4% or better and then filled to uniform pressure with Ar standard gases. This experimental design eliminates sample heterogeneity, leaving only interlaboratory variations in gas purification, data reduction, and isotopic measurement as potential sources of interlaboratory calibration discrepancies. APIS-1 was designated as a traveling unit that is brought to participating labs. APIS-2 is the reserve/master standard. Currently, APIS-1 is in its early stages in the voyage and has been to three labs (Rutgers, LDEO, and New Mexico Tech) as of this writing. The interlaboratory comparisons are ongoing, and will include ASU, BGC, Univ. of Wisconsin, and Oregon State University, plus additional laboratories of opportunity. A progress report will be presented at AGU.

  1. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  2. Interlaboratory round robin study on axial tensile properties of SiC-SiC CMC tubular test specimens [Interlaboratory round robin study on axial tensile properties of SiC/SiC tubes

    DOE PAGES

    Singh, Gyanender P.; Gonczy, Steve T.; Deck, Christian P.; ...

    2018-04-19

    An interlaboratory round robin study was conducted on the tensile strength of SiC–SiC ceramic matrix composite (CMC) tubular test specimens at room temperature with the objective of expanding the database of mechanical properties of nuclear grade SiC–SiC and establishing the precision and bias statement for standard test method ASTM C1773. The mechanical properties statistics from the round robin study and the precision statistics and precision statement are presented herein. The data show reasonable consistency across the laboratories, indicating that the current C1773–13 ASTM standard is adequate for testing ceramic fiber reinforced ceramic matrix composite tubular test specimen. Furthermore, it wasmore » found that the distribution of ultimate tensile strength data was best described with a two–parameter Weibull distribution, while a lognormal distribution provided a good description of the distribution of proportional limit stress data.« less

  3. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--part 2: forensic inter-laboratory trial: bulk carbon and nitrogen stable isotopes in a range of chemical compounds (Australia and New Zealand).

    PubMed

    Benson, Sarah J; Lennard, Christopher J; Maynard, Philip; Hill, David M; Andrew, Anita S; Neal, Ken; Stuart-Williams, Hilary; Hope, Janet; Walker, G Stewart; Roux, Claude

    2010-01-01

    Comparability of data over time and between laboratories is a key issue for consideration in the development of global databases, and more broadly for quality assurance in general. One mechanism that can be utilized for evaluating traceability is an inter-laboratory trial. This paper addresses an inter-laboratory trial conducted across a number of Australian and New Zealand isotope ratio mass spectrometry (IRMS) laboratories. The main objective of this trial was to determine whether IRMS laboratories in these countries would record comparable values for the distributed samples. Four carbon containing and four nitrogen containing compounds were distributed to seven laboratories in Australia and one in New Zealand. The laboratories were requested to analyze the samples using their standard procedures. The data from each laboratory was evaluated collectively using International Standard ISO 13528 (Statistical methods for use in proficiency testing by inter-laboratory comparisons). "Warning signals" were raised against one participant in this trial. "Action signals" requiring corrective action were raised against four participants. These participants reviewed the data and possible sources for the discrepancies. This inter-laboratory trial was successful in providing an initial snapshot of the potential for traceability between the participating laboratories. The statistical methods described in this article could be used as a model for others needing to evaluate stable isotope results derived from multiple laboratories, e.g., inter-laboratory trials/proficiency testing. Ongoing trials will be conducted to improve traceability across the Australian and New Zealand IRMS community.

  4. Report on the U.S. Geological Survey's Evaluation Program Standard Reference Samples Distributed in October 1995: T-137 (Trace Constituents), M-136 (Major Constituents), N-47 (Nutrient Constituents), N-48 (Nutrient Constituents), P-25 (Low Ionic Strength Constituents), and Hg-21 (Mercury)

    USGS Publications Warehouse

    Farrar, Jerry W.; Long, H. Keith

    1996-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 6 standard reference samples--T-137 (trace constituents), M-136 (major constituents), N-47 (nutrient constituents), N-48 (nutrient constituents), P-25 (low ionic strength constituents), and Hg-21 (mercury)--that were distributed in October 1995 to 149 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the six reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the six standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  5. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1994; T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), and Hg-18 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for five standard reference samples--T-129 (trace constituents), M-130 (major constituents), N-42 (nutrients), P-22 (low ionic strength), Hg-18(mercury),--that were distributed in April 1994 to 157 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 133 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the five reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the five standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  6. Report of the U.S. Geological Survey's evaluation program for standard reference samples distributed in April 1993; T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents, N-38 (nutrients), N-39 (nutrients), P-20 (low ionic strength, and Hg-16 (mercury)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1993-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples--T-123 (trace constituents), T-125 (trace constituents), M-126 (major constituents), N-38 (nutrients), N-39 (Nutrients), P-20 (precipitation-low ionic strength), and Hg-16 (mercury)--that were distributed in April 1993 to 175 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data received from 131 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the 7 reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  7. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples distributed in March 1999

    USGS Publications Warehouse

    Farrar, Jerry W.; Chleboun, Kimberly M.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 8 standard reference samples -- T-157 (trace constituents), M-150 (major constituents), N-61 (nutrient constituents), N-62 (nutrient constituents), P-32 (low ionic strength constituents), GWT-5 (ground-water trace constituents), GWM- 4 (ground-water major constituents),and Hg-28 (mercury) -- that were distributed in March 1999 to 120 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 111 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the 8 standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  8. Toward the Standardization of Biochar Analysis: The COST Action TD1107 Interlaboratory Comparison.

    PubMed

    Bachmann, Hans Jörg; Bucheli, Thomas D; Dieguez-Alonso, Alba; Fabbri, Daniele; Knicker, Heike; Schmidt, Hans-Peter; Ulbricht, Axel; Becker, Roland; Buscaroli, Alessandro; Buerge, Diane; Cross, Andrew; Dickinson, Dane; Enders, Akio; Esteves, Valdemar I; Evangelou, Michael W H; Fellet, Guido; Friedrich, Kevin; Gasco Guerrero, Gabriel; Glaser, Bruno; Hanke, Ulrich M; Hanley, Kelly; Hilber, Isabel; Kalderis, Dimitrios; Leifeld, Jens; Masek, Ondrej; Mumme, Jan; Carmona, Marina Paneque; Calvelo Pereira, Roberto; Rees, Frederic; Rombolà, Alessandro G; de la Rosa, José Maria; Sakrabani, Ruben; Sohi, Saran; Soja, Gerhard; Valagussa, Massimo; Verheijen, Frank; Zehetner, Franz

    2016-01-20

    Biochar produced by pyrolysis of organic residues is increasingly used for soil amendment and many other applications. However, analytical methods for its physical and chemical characterization are yet far from being specifically adapted, optimized, and standardized. Therefore, COST Action TD1107 conducted an interlaboratory comparison in which 22 laboratories from 12 countries analyzed three different types of biochar for 38 physical-chemical parameters (macro- and microelements, heavy metals, polycyclic aromatic hydrocarbons, pH, electrical conductivity, and specific surface area) with their preferential methods. The data were evaluated in detail using professional interlaboratory testing software. Whereas intralaboratory repeatability was generally good or at least acceptable, interlaboratory reproducibility was mostly not (20% < mean reproducibility standard deviation < 460%). This paper contributes to better comparability of biochar data published already and provides recommendations to improve and harmonize specific methods for biochar analysis in the future.

  9. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    PubMed

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  10. Using an interlaboratory study to revise methods for conducting 10-d to 42-d water or sediment toxicity tests with Hyalella azteca

    USGS Publications Warehouse

    Ivey, Chris D.; Ingersoll, Christopher G.; Brumbaugh, William G.; Hammer, Edward J.; Mount, David R.; Hockett, J. Russell; Norberg-King, Teresa J.; Soucek, Dave; Taylor, Lisa

    2016-01-01

    Studies have been conducted to refine US Environmental Protection Agency, ASTM International, and Environment Canada standard methods for conducting 42-d reproduction tests with Hyalella azteca in water or in sediment. Modifications to the H. azteca method include better-defined ionic composition requirements for exposure water (i.e., >15 mg/L of chloride and >0.02 mg/L of bromide) and improved survival, growth, and reproduction with alternate diets provided as increased rations over time in water-only or whole-sediment toxicity tests. A total of 24 laboratories volunteered to participate in the present interlaboratory study evaluating the performance of H. azteca in 42-d studies in control sand or control sediment using the refined methods. Improved growth and reproduction of H. azteca was observed with 2 alternate diets of 1) ramped diatoms (Thalassiosira weissflogii) + ramped Tetramin or 2) yeast–cerophyll–trout chow (YCT) + ramped Tetramin, especially when compared with results from the traditional diet of 1.8 mg YCT/d. Laboratories were able to meet proposed test acceptability criteria and in most cases had lower variation in growth or reproduction compared with previous interlaboratory studies using the traditional YCT diet. Laboratory success in conducting 42-d H. azteca exposures benefited from adherence to several key requirements of the detailed testing, culturing, and handling methods. Results from the present interlaboratory study are being used to help revise standard methods for conducting 10-d to 42-d water or sediment toxicity exposures with H. azteca.

  11. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    NASA Astrophysics Data System (ADS)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  12. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 2)].

    PubMed

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Yamada, Kyohei; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.

  13. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  14. Interlaboratory evaluation of trace element determination in workplace air filter samples by inductively coupled plasma mass spectrometry†‡

    PubMed Central

    Shulman, Stanley A.; Brisson, Michael J.; Howe, Alan M.

    2015-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is becoming more widely used for trace elemental analysis in the occupational hygiene field, and consequently new ICP-MS international standard procedures have been promulgated by ASTM International and ISO. However, there is a dearth of interlaboratory performance data for this analytical methodology. In an effort to fill this data void, an interlaboratory evaluation of ICP-MS for determining trace elements in workplace air samples was conducted, towards fulfillment of method validation requirements for international voluntary consensus standard test methods. The study was performed in accordance with applicable statistical procedures for investigating interlaboratory precision. The evaluation was carried out using certified 37-mm diameter mixed-cellulose ester (MCE) filters that were fortified with 21 elements of concern in occupational hygiene. Elements were spiked at levels ranging from 0.025 to 10 μg filter−1, with three different filter loadings denoted “Low”, “Medium” and “High”. Participating laboratories were recruited from a pool of over fifty invitees; ultimately twenty laboratories from Europe, North America and Asia submitted results. Triplicates of each certified filter with elemental contents at three different levels, plus media blanks spiked with reagent, were conveyed to each volunteer laboratory. Each participant was also provided a copy of the test method which each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the filters by one of three sample preparation procedures, i.e., hotplate digestion, microwave digestion or hot block extraction, which were described in the test method. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS, and to report their data in units of μg filter−1. Most interlaboratory precision estimates were acceptable for medium- and high-level spikes (RSD <25%), but generally yielded greater uncertainties than were anticipated at the outset of the study. PMID:22038017

  15. Interlaboratory ring trial to evaluate CFT proficiency of European laboratories for diagnosis of glanders in equids.

    PubMed

    Laroucau, K; Colaneri, C; Jaÿ, M; Corde, Y; Drapeau, A; Durand, B; Zientara, S; Beck, C

    2016-06-18

    To evaluate the routine complement fixation test (CFT) used to detect Burkholderia mallei antibodies in equine sera, an interlaboratory proficiency test was held with 24 European laboratories, including 22 National Reference Laboratories for glanders. The panels sent to participants were composed of sera with or without B mallei antibodies. This study confirmed the reliability of CFT and highlighted its intralaboratory reproducibility. However, the sensitivity of glanders serodiagnosis and laboratory proficiency may be improved by standardising critical reagents, including antigens, and by developing a standard B mallei serum. British Veterinary Association.

  16. Results of the U.S. Geological Survey's Analytical Evaluation Program for standard reference samples: T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents) and Hg-27 (Mercury) distributed in September 1998

    USGS Publications Warehouse

    Farrar, Jerry W.

    1999-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for seven standard reference samples -- T-155 (trace constituents), M-148 (major constituents), N-59 (nutrient constituents), N-60 (nutrient constituents), P-31 (low ionic strength constituents), GWT-4 (ground-water trace constituents), and Hg- 27 (mercury) -- which were distributed in September 1998 to 162 laboratories enrolled in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 136 of the laboratories were evaluated with respect to overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  17. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1993 : T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)

    USGS Publications Warehouse

    Long, H.K.; Farrar, J.W.

    1994-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for eight standard reference samples--T-127 (trace constituents), M-128 (major constituents), N-40 (nutrients), N-41 (nutrients), P-21 (low ionic strength), Hg-17 (mercury), AMW-3 (acid mine water), and WW-1 (whole water)--that were distributed in October 1993 to 158 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 145 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the eight reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the eight standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  18. Report on the U.S. Geological Survey's evaluation program for standard reference samples distributed in October 1994 : T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength) and Hg-19 (mercury)

    USGS Publications Warehouse

    Long, H. Keith; Farrar, Jerry W.

    1995-01-01

    This report presents the results of the U.S. Geological Survey's analytical evaluation program for 7 standard reference samples--T-131 (trace constituents), T-133 (trace constituents), M-132 (major constituents), N-43 (nutrients), N-44 (nutrients), P-23 (low ionic strength), and Hg-19 (mercury). The samples were distributed in October 1994 to 131 laboratories registered in the U.S. Geological Survey sponsored interlaboratory testing program. Analytical data that were received from 121 of the laboratories were evaluated with respect to: overall laboratory performance and relative laboratory performance for each analyte in the seven reference samples. Results of these evaluations are presented in tabular form. Also presented are tables and graphs summarizing the analytical data provided by each laboratory for each analyte in the seven standard reference samples. The most probable value for each analyte was determined using nonparametric statistics.

  19. Interlaboratory evaluation of a standardized inductively coupled plasma mass spectrometry method for the determination of trace beryllium in air filter samples.

    PubMed

    Ashley, Kevin; Brisson, Michael J; Howe, Alan M; Bartley, David L

    2009-12-01

    A collaborative interlaboratory evaluation of a newly standardized inductively coupled plasma mass spectrometry (ICP-MS) method for determining trace beryllium in workplace air samples was carried out toward fulfillment of method validation requirements for ASTM International voluntary consensus standard test methods. The interlaboratory study (ILS) was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Uncertainty was also estimated in accordance with ASTM D7440, which applies the International Organization for Standardization Guide to the Expression of Uncertainty in Measurement to air quality measurements. Performance evaluation materials (PEMs) used consisted of 37 mm diameter mixed cellulose ester filters that were spiked with beryllium at levels of 0.025 (low loading), 0.5 (medium loading), and 10 (high loading) microg Be/filter; these spiked filters were prepared by a contract laboratory. Participating laboratories were recruited from a pool of over 50 invitees; ultimately, 20 laboratories from Europe, North America, and Asia submitted ILS results. Triplicates of each PEM (blanks plus the three different loading levels) were conveyed to each volunteer laboratory, along with a copy of the draft standard test method that each participant was asked to follow; spiking levels were unknown to the participants. The laboratories were requested to prepare the PEMs by one of three sample preparation procedures (hotplate or microwave digestion or hotblock extraction) that were described in the draft standard. Participants were then asked to analyze aliquots of the prepared samples by ICP-MS and to report their data in units of mu g Be/filter sample. Interlaboratory precision estimates from participating laboratories, computed in accordance with ASTM E691, were 0.165, 0.108, and 0.151 (relative standard deviation) for the PEMs spiked at 0.025, 0.5, and 10 microg Be/filter, respectively. Overall recoveries were 93.2%, 102%, and 80.6% for the low, medium, and high beryllium loadings, respectively. Expanded uncertainty estimates for interlaboratory analysis of low, medium, and high beryllium loadings, calculated in accordance with ASTM D7440, were 18.8%, 19.8%, and 24.4%, respectively. These figures of merit support promulgation of the analytical procedure as an ASTM International standard test method, ASTM D7439.

  20. Predictive performance and inter-laboratory reproducibility in assessing eye irritation potential of water- and oil-soluble mixtures using the Short Time Exposure test method.

    PubMed

    Abo, Takayuki; Hilberer, Allison; Behle-Wagner, Christine; Watanabe, Mika; Cameron, David; Kirst, Annette; Nukada, Yuko; Yuki, Takuo; Araki, Daisuke; Sakaguchi, Hitoshi; Itagaki, Hiroshi

    2018-04-01

    The Short Time Exposure (STE) test method is an alternative method for assessing eye irritation potential using Statens Seruminstitut Rabbit Cornea cells and has been adopted as test guideline 491 by the Organisation for Economic Co-operation and Development. Its good predictive performance in identifying the Globally Harmonized System (GHS) No Category (NC) or Irritant Category has been demonstrated in evaluations of water-soluble substances, oil-soluble substances, and water-soluble mixtures. However, the predictive performance for oil-soluble mixtures was not evaluated. Twenty-four oil-soluble mixtures were evaluated using the STE test method. The GHS NC or Irritant Category of 22 oil-soluble mixtures were consistent with that of a Reconstructed human Cornea-like Epithelium (RhCE) test method. Inter-laboratory reproducibility was then confirmed using 20 water- and oil-soluble mixtures blind-coded. The concordance in GHS NC or Irritant Category among four laboratories was 90%-100%. In conclusion, the concordance in comparison with the results of RhCE test method using 24 oil-soluble mixtures and inter-laboratory reproducibility using 20 water- and oil-soluble mixtures blind-coded were good, indicating that the STE test method is a suitable alternative for predicting the eye irritation potential of both substances and mixtures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Interlaboratory comparability, bias, and precision for four laboratories measuring analytes in wet deposition, October 1983-December 1984

    USGS Publications Warehouse

    Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1987-01-01

    Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.

  2. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    PubMed

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  3. Interlaboratory Reproducibility and Proficiency Testing within the Human Papillomavirus Cervical Cancer Screening Program in Catalonia, Spain

    PubMed Central

    Ibáñez, R.; Félez-Sánchez, M.; Godínez, J. M.; Guardià, C.; Caballero, E.; Juve, R.; Combalia, N.; Bellosillo, B.; Cuevas, D.; Moreno-Crespi, J.; Pons, L.; Autonell, J.; Gutierrez, C.; Ordi, J.; de Sanjosé, S.

    2014-01-01

    In Catalonia, a screening protocol for cervical cancer, including human papillomavirus (HPV) DNA testing using the Digene Hybrid Capture 2 (HC2) assay, was implemented in 2006. In order to monitor interlaboratory reproducibility, a proficiency testing (PT) survey of the HPV samples was launched in 2008. The aim of this study was to explore the repeatability of the HC2 assay's performance. Participating laboratories provided 20 samples annually, 5 randomly chosen samples from each of the following relative light unit (RLU) intervals: <0.5, 0.5 to 0.99, 1 to 9.99, and ≥10. Kappa statistics were used to determine the agreement levels between the original and the PT readings. The nature and origin of the discrepant results were calculated by bootstrapping. A total of 946 specimens were retested. The kappa values were 0.91 for positive/negative categorical classification and 0.79 for the four RLU intervals studied. Sample retesting yielded systematically lower RLU values than the original test (P < 0.005), independently of the time elapsed between the two determinations (median, 53 days), possibly due to freeze-thaw cycles. The probability for a sample to show clinically discrepant results upon retesting was a function of the RLU value; samples with RLU values in the 0.5 to 5 interval showed 10.80% probability to yield discrepant results (95% confidence interval [CI], 7.86 to 14.33) compared to 0.85% probability for samples outside this interval (95% CI, 0.17 to 1.69). Globally, the HC2 assay shows high interlaboratory concordance. We have identified differential confidence thresholds and suggested the guidelines for interlaboratory PT in the future, as analytical quality assessment of HPV DNA detection remains a central component of the screening program for cervical cancer prevention. PMID:24574284

  4. A 7-d toxicity test for marine pollutants using the Pacific mysid Mysidopsis intii. 2: Protocol evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmon, V.L.; Langdon, C.J.

    1996-10-01

    The sensitivity of the Pacific coast mysid Mysidopsis intii to pollutants was compared in 7-d toxicity tests with that of the Gulf coast mysid M. bahia and the Pacific coast mysid Holmesimysis costata. Survival and growth responses of M. intii to zinc (maximum acceptable toxicant concentration [MATC] survival and growth, 152 {micro}g/L) were as sensitive as survival of both M. bahia (MATC survival, 152 {micro}g/L) and H. costata (MATC survival, 152 {micro}g/L). In contrast, the 7-d test for M. intii was less sensitive (MATC growth and survival, 4.99 mg/L) than the test for H. costata (MATC survival, 1.99 mg/L) whenmore » sodium dodecyl sulfate (SDS) was used as the toxicant. Interlaboratory evaluation of the 7-d test for M. intii exposed to SDS indicated that the test was reliable. The mean test results for the group of participating laboratories were not significantly different from those of a group of three in-house tests, indicating that shipping and handling did not affect mysid sensitivity to SDS. Mysid growth was not as sensitive to SDS as survival in the interlaboratory tests. Although there were significant differences in median lethal concentration (LC50) values among participating laboratories, coefficients of variation of LC50 and MATC survival values among laboratories were 10.3 and 37%, respectively. These coefficients were comparable to those reported for interlaboratory tests with H. costata.« less

  5. Interlaboratory comparison of measurements of acid-volatile sulfide and simultaneously extracted nickel in spiked sediments

    USGS Publications Warehouse

    Brumbaugh, William G.; Hammerschmidt, Chad R.; Zanella, Luciana; Rogevich, Emily; Salata, Gregory; Bolek, Radoslaw

    2011-01-01

    An interlaboratory comparison of acid-volatile sulfide (AVS) and simultaneously extracted nickel (SEM_Ni) measurements of sediments was conducted among five independent laboratories. Relative standard deviations for the seven test samples ranged from 5.6 to 71% (mean = 25%) for AVS and from 5.5 to 15% (mean = 10%) for SEM_Ni. These results are in stark contrast to a recently published study that indicated AVS and SEM analyses were highly variable among laboratories.

  6. [Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 1)].

    PubMed

    Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Tonooka, Hiroyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Watanabe, Kazunari; Sato, Kyoko

    2018-01-01

    An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using three food-simulating solvents (water, 4% acetic acid and 20% ethanol), based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. For evaporation, a water bath was used in the official method, and a hot plate in the modified method. In most laboratories, the test solutions were heated until just prior to evaporation to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods, regardless of the heating equipment used. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method.

  7. A scoring metric for multivariate data for reproducibility analysis using chemometric methods

    PubMed Central

    Sheen, David A.; de Carvalho Rocha, Werickson Fortunato; Lippa, Katrice A.; Bearden, Daniel W.

    2017-01-01

    Process quality control and reproducibility in emerging measurement fields such as metabolomics is normally assured by interlaboratory comparison testing. As a part of this testing process, spectral features from a spectroscopic method such as nuclear magnetic resonance (NMR) spectroscopy are attributed to particular analytes within a mixture, and it is the metabolite concentrations that are returned for comparison between laboratories. However, data quality may also be assessed directly by using binned spectral data before the time-consuming identification and quantification. Use of the binned spectra has some advantages, including preserving information about trace constituents and enabling identification of process difficulties. In this paper, we demonstrate the use of binned NMR spectra to conduct a detailed interlaboratory comparison and composition analysis. Spectra of synthetic and biologically-obtained metabolite mixtures, taken from a previous interlaboratory study, are compared with cluster analysis using a variety of distance and entropy metrics. The individual measurements are then evaluated based on where they fall within their clusters, and a laboratory-level scoring metric is developed, which provides an assessment of each laboratory’s individual performance. PMID:28694553

  8. Report on the CCT Supplementary Comparison S1 of Infrared Spectral Normal Emittance/Emissivity

    PubMed Central

    Hanssen, Leonard; Wilthan, B.; Monte, Christian; Hollandt, Jörg; Hameury, Jacques; Filtz, Jean-Remy; Girard, Ferruccio; Battuello, Mauro; Ishii, Juntaro

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes’ infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. PMID:28239193

  9. Practical methodological guide for hydrometric inter-laboratory organisation

    NASA Astrophysics Data System (ADS)

    Besson, David; Bertrand, Xavier

    2015-04-01

    Discharge measurements performed by the French governmental hydrometer team feed a national database. This data is available for general river flows knowkedge, flood forecasting, low water survey, statistical calculations flow, control flow regulatory and many other uses. Regularly checking the measurements quality and better quantifying its accuracy is therefore an absolute need. The practice of inter-laboratory comparison in hydrometry particularly developed during the last decade. Indeed, discharge measurement can not easily be linked to a standard. Therefore, on-site measurement accuracy control is very difficult. Inter-laboratory comparison is thus a practical solution to this issue. However, it needs some regulations in order to ease its practice and legitimize its results. To do so, the French government hydrometrics teams produced a practical methodological guide for hydrometric inter-laboratory organisation in destination of hydrometers community in view of ensure the harmonization of inter-laboratory comparison practices for different materials (ADCP, current meter on wadind rod or gauging van, tracer dilution, surface speed) and flow range (flood, low water). Ensure the results formalization and banking. The realisation of this practice guide is grounded on the experience of the governmental teams & their partners (or fellows), following existing approaches (Doppler group especially). The guide is designated to validate compliance measures and identify outliers : Hardware, methodological, environmental, or human. Inter-laboratory comparison provides the means to verify the compliance of the instruments (devices + methods + operators) and provides methods to determine an experimental uncertainty of the tested measurement method which is valid only for the site and the measurement conditions but does not address the calibration or periodic monitoring of the few materials. After some conceptual definitions, the guide describes the different stages of an inter-comparison campaign: the campaing creation: targets, participants ( instruments type and number) and site preparation of test protocols and schedule; the campaign set-up (organization): invitation and pre-information of the participants, logistics, field preparation; the campaign conduct: participants reception and information, sequences of tests, results analysis and communication, balance sheet; post-campaign work: further analysis, dissemination and periodic verification of the instruments. This guide is associated with measurement instruments forms, reminding their limits and conditions for use, land forms, used to record all the necessary information during the inter-comparison campaign (site description and measurement conditions, equipment and its settings, and the set of measurements or intermediate calculations to the final results) as well as a calculation tool and banking measures and results.

  10. Validation of Dissolution Testing with Biorelevant Media: An OrBiTo Study.

    PubMed

    Mann, James; Dressman, Jennifer; Rosenblatt, Karin; Ashworth, Lee; Muenster, Uwe; Frank, Kerstin; Hutchins, Paul; Williams, James; Klumpp, Lukas; Wielockx, Kristina; Berben, Philippe; Augustijns, Patrick; Holm, Rene; Hofmann, Michael; Patel, Sanjaykumar; Beato, Stefania; Ojala, Krista; Tomaszewska, Irena; Bruel, Jean-Luc; Butler, James

    2017-12-04

    Dissolution testing with biorelevant media has become widespread in the pharmaceutical industry as a means of better understanding how drugs and formulations behave in the gastrointestinal tract. Until now, however, there have been few attempts to gauge the reproducibility of results obtained with these methods. The aim of this study was to determine the interlaboratory reproducibility of biorelevant dissolution testing, using the paddle apparatus (USP 2). Thirteen industrial and three academic laboratories participated in this study. All laboratories were provided with standard protocols for running the tests: dissolution in FaSSGF to simulate release in the stomach, dissolution in a single intestinal medium, FaSSIF, to simulate release in the small intestine, and a "transfer" (two-stage) protocol to simulate the concentration profile when conditions are changed from the gastric to the intestinal environment. The test products chosen were commercially available ibuprofen tablets and zafirlukast tablets. The biorelevant dissolution tests showed a high degree of reproducibility among the participating laboratories, even though several different batches of the commercially available medium preparation powder were used. Likewise, results were almost identicalbetween the commercial biorelevant media and those produced in-house. Comparing results to previous ring studies, including those performed with USP calibrator tablets or commercially available pharmaceutical products in a single medium, the results for the biorelevant studies were highly reproducible on an interlaboratory basis. Interlaboratory reproducibility with the two-stage test was also acceptable, although the variability was somewhat greater than with the single medium tests. Biorelevant dissolution testing is highly reproducible among laboratories and can be relied upon for cross-laboratory comparisons.

  11. Interlaboratory evaluation of Hyalella azteca and Chironomus tentans short-term and long-term sediment toxicity tests

    USGS Publications Warehouse

    Norberg-King, T. J.; Sibley, P.K.; Burton, G.A.; Ingersoll, C.G.; Kemble, N.E.; Ireland, S.; Mount, D.R.; Rowland, C.D.

    2006-01-01

    Methods for assessing the long-term toxicity of sediments to Hyalella azteca and Chironomus tentans can significantly enhance the capacity to assess sublethal effects of contaminated sediments through multiple endpoints. Sublethal tests allow us to begin to understand the relationship between short-term and long-term effects for toxic sediments. We present an interlaboratory evaluation with long-term and 10-d tests using control and contaminated sediments in which we assess whether proposed and existing performance criteria (test acceptability criteria [TAC]) could be achieved. Laboratories became familiar with newly developed, long-term protocols by testing two control sediments in phase 1. In phase 2, the 10-d and long-term tests were examined with several sediments. Laboratories met the TACs, but results varied depending on the test organism, test duration, and endpoints. For the long-term tests in phase 1, 66 to 100% of the laboratories consistently met the TACs for survival, growth, or reproduction using H. azteca, and 70 to 100% of the laboratories met the TACs for survival and growth, emergence, reproduction, and hatchability using C. tentans. In phase 2, fewer laboratories participated in long-term tests: 71 to 88% of the laboratories met the TAC for H. azteca, whereas 50 to 67% met the TAC for C. tentans. In the 10-d tests with H. azteca, and C. tentans, 82 and 88% of the laboratories met the TAC for survival, respectively, and 80% met the TAC for C. tentans growth. For the 10-d and long-term tests, laboratories predicted similar toxicity. Overall, the interlaboratory evaluation showed good precision of the methods, appropriate endpoints were incorporated into the test protocols, and tests effectively predicted the toxicity of sediments.

  12. Assessing variability in chemical acute toxicity of unionid mussels: Influence of intra- and inter-laboratory testing, life stage, and species

    USGS Publications Warehouse

    Raimondo, Sandy; Lilavois, Crystal R.; Lee, Larisa; Augspurger, Tom; Wang, Ning; Ingersoll, Christopher G.; Bauer, Candice R.; Hammer, Edward J.; Barron, Mace G.

    2016-01-01

    We developed a toxicity database for unionid mussels to examine the extent of intra- and inter-laboratory variability in acute toxicity tests with mussel larvae (glochidia) and juveniles; the extent of differential sensitivity of the two life stages; and the variation in sensitivity among commonly tested mussels (Lampsilis siliquoidea, Utterbackia imbecillis, Villosa iris), commonly tested cladocerans (Daphnia magna, Ceriodaphnia dubia) and fish (Oncorhynchus mykiss, Pimephales promelas, Lepomis macrochirus). The results of these analyses indicate intra-laboratory variability for median effect concentrations (EC50) averaged about 2 fold for both life stages, while inter-laboratory variability averaged 3.6 fold for juvenile mussels and 6.3 fold for glochidia. The EC50s for juveniles and glochidia were within a factor of 2 of each other for 50% of paired records across chemicals, with juveniles more sensitive than glochidia by more than 2 fold for 33% of the comparisons made between life stages. There was a high concurrence of the sensitivity of commonly tested L. siliquoidea, U. imbecillis, and V. iris to that of other mussels. However, this concurrence decreases as the taxonomic distance of the commonly tested cladocerans and fish to mussels increases. The compiled mussel database and determination of data variability will advance risk assessments by including more robust species sensitivity distributions, interspecies correlation estimates, and availability of taxon-specific empirically derived application factors for risk assessment.

  13. Quality assurance in RT-PCR-based BCR/ABL diagnostics--results of an interlaboratory test and a standardization approach.

    PubMed

    Burmeister, T; Maurer, J; Aivado, M; Elmaagacli, A H; Grünebach, F; Held, K R; Hess, G; Hochhaus, A; Höppner, W; Lentes, K U; Lübbert, M; Schäfer, K L; Schafhausen, P; Schmidt, C A; Schüler, F; Seeger, K; Seelig, R; Thiede, C; Viehmann, S; Weber, C; Wilhelm, S; Christmann, A; Clement, J H; Ebener, U; Enczmann, J; Leo, R; Schleuning, M; Schoch, R; Thiel, E

    2000-10-01

    Here we describe the results of an interlaboratory test for RT-PCR-based BCR/ABL analysis. The test was organized in two parts. The number of participating laboratories in the first and second part was 27 and 20, respectively. In the first part samples containing various concentrations of plasmids with the ela2, b2a2 or b3a2 BCR/ABL transcripts were analyzed by PCR. In the second part of the test, cell samples containing various concentrations of BCR/ABL-positive cells were analyzed by RT-PCR. Overall PCR sensitivity was sufficient in approximately 90% of the tests, but a significant number of false positive results were obtained. There were significant differences in sensitivity in the cell-based analysis between the various participants. The results are discussed, and proposals are made regarding the choice of primers, controls, conditions for RNA extraction and reverse transcription.

  14. Inter-laboratory analysis of selected genetically modified plant reference materials with digital PCR.

    PubMed

    Dobnik, David; Demšar, Tina; Huber, Ingrid; Gerdes, Lars; Broeders, Sylvia; Roosens, Nancy; Debode, Frederic; Berben, Gilbert; Žel, Jana

    2018-01-01

    Digital PCR (dPCR), as a new technology in the field of genetically modified (GM) organism (GMO) testing, enables determination of absolute target copy numbers. The purpose of our study was to test the transferability of methods designed for quantitative PCR (qPCR) to dPCR and to carry out an inter-laboratory comparison of the performance of two different dPCR platforms when determining the absolute GM copy numbers and GM copy number ratio in reference materials certified for GM content in mass fraction. Overall results in terms of measured GM% were within acceptable variation limits for both tested dPCR systems. However, the determined absolute copy numbers for individual genes or events showed higher variability between laboratories in one third of the cases, most possibly due to variability in the technical work, droplet size variability, and analysis of the raw data. GMO quantification with dPCR and qPCR was comparable. As methods originally designed for qPCR performed well in dPCR systems, already validated qPCR assays can most generally be used for dPCR technology with the purpose of GMO detection. Graphical abstract The output of three different PCR-based platforms was assessed in an inter-laboratory comparison.

  15. Transferability and inter-laboratory variability assessment of the in vitro bovine oocyte fertilization test.

    PubMed

    Tessaro, Irene; Modina, Silvia C; Crotti, Gabriella; Franciosi, Federica; Colleoni, Silvia; Lodde, Valentina; Galli, Cesare; Lazzari, Giovanna; Luciano, Alberto M

    2015-01-01

    The dramatic increase in the number of animals required for reproductive toxicity testing imposes the validation of alternative methods to reduce the use of laboratory animals. As we previously demonstrated for in vitro maturation test of bovine oocytes, the present study describes the transferability assessment and the inter-laboratory variability of an in vitro test able to identify chemical effects during the process of bovine oocyte fertilization. Eight chemicals with well-known toxic properties (benzo[a]pyrene, busulfan, cadmium chloride, cycloheximide, diethylstilbestrol, ketoconazole, methylacetoacetate, mifepristone/RU-486) were tested in two well-trained laboratories. The statistical analysis demonstrated no differences in the EC50 values for each chemical in within (inter-runs) and in between-laboratory variability of the proposed test. We therefore conclude that the bovine in vitro fertilization test could advance toward the validation process as alternative in vitro method and become part of an integrated testing strategy in order to predict chemical hazards on mammalian fertility. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Analytical Round Robin for Elastic-Plastic Analysis of Surface Cracked Plates, Phase II Results

    NASA Technical Reports Server (NTRS)

    Allen, P. A.; Wells, D. N.

    2017-01-01

    The second phase of an analytical round robin for the elastic-plastic analysis of surface cracks in flat plates was conducted under the auspices of ASTM Interlaboratory Study 732. The interlaboratory study (ILS) had 10 participants with a broad range of expertise and experience, and experimental results from a surface crack tension test in 4142 steel plate loaded well into the elastic-plastic regime provided the basis for the study. The participants were asked to evaluate a surface crack tension test according to the version of the surface crack initiation toughness testing standard published at the time of the ILS, E2899-13. Data were provided to each participant that represent the fundamental information that would be provided by a mechanical test laboratory prior to evaluating the test result. Overall, the participant’s test analysis results were in good agreement and constructive feedback was received that has resulted in an improved published version of the standard E2899-15.

  17. An inter-laboratory comparison study of the ANSI/BIFMA standard test method M7.1 for furniture

    EPA Science Inventory

    Five laboratories using five different test chambers participated in the study to quantify within- and between-laboratory variability in the measurement of emissions of volatile organic compounds (VOCs) from new commercial furniture test items following ANSI/BIFMA M7.1. Test item...

  18. Toward Improvements in Inter-laboratory Calibration of Argon Isotope Measurements

    NASA Astrophysics Data System (ADS)

    Hemming, S. R.; Deino, A. L.; Heizler, M. T.; Hodges, K. V.; McIntosh, W. C.; Renne, P. R.; Swisher, C. C., III; Turrin, B. D.; Van Soest, M. C.

    2015-12-01

    It is important to continue to develop strategies to improve our ability to compare results between laboratories chronometers. The U-Pb community has significantly reduced inter-laboratory biases with the application of a community tracer solution and the distribution of synthetic zircon solutions. Inevitably sample selection and processing and even biases in interpretations will still lead to some disagreements in the assignment of ages. Accordingly natural samples that are shared will be important for achievement of the highest levels of agreement. Analogous improvements in quality and inter-laboratory agreement of analytical aspects of Ar-Ar can be achieved through development of synthetic age standards in gas canisters with multiple pipettes to deliver various controlled amounts of argon to the mass spectrometer. A preliminary proof-of concept comes from the inter-laboratory calibration experiment for the 40Ar/39Ar community. This portable Argon Pipette Intercalibration System (APIS) consists of three 2.7 L canisters each equipped with three pipettes of 0.1, 0.2 and 0.4 cc volumes. The currently traveling APIS has the three canisters filled with air and 40Ar*/39Ar of 1.73 and canister 2 has a 40Ar*/39Ar of 40.98 (~ Alder Creek and Fish Canyon in the same irradiation). With these pipettes it is possible to combine them to provide 0.1, 0.2, 0.3 (0.1+0.2), 0.4, 0.5 (0.1+0.4), 0.6 (0.2+0.4), and 0.7 (0.1+0.2+0.4) cc. The configuration allows a simple test for inter-laboratory biases and for volume/pressure dependent mass fractionation on the measured ratios for a gas with a single argon isotope composition. Although not yet tested, it is also possible to mix gas from any one of the three canisters in proportions of these increments, allowing even more tightly controlled calibration of measurements. We suggest that ultimately each EARTHTIME lab should be equipped with such a system permanently, with a community plan for a traveling system to periodically repeat the inter-calibration tests. The composition(s) of such systems may not be the same for each lab, depending on the requirements of equipment and main age ranges targeted. But with a relatively small number of end member compositions it should be possible to greatly improve the calibration capability of the community.

  19. The determination of ethyl glucuronide in hair: Experiences from nine consecutive interlaboratory comparison rounds.

    PubMed

    Becker, R; Lô, I; Sporkert, F; Baumgartner, M

    2018-07-01

    The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80pg/mg were provided for 27-35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Lupus anticoagulants: first French interlaboratory Etalonorme survey.

    PubMed

    Roussi, J; Roisin, J P; Goguel, A

    1996-06-01

    In 1994, the, French National Quality Control Group for Hematology, Etalonorme, conducted a large-scale interlaboratory survey concerning the detection of lupus anticoagulants (LA) involving all the 4,500 French laboratories. Each laboratory received the same batch of a lyophilized citrated plasma (94B3) prepared from a patient with LA that had been confirmed by all the techniques used in the intralaboratory study. In the interlaboratory survey, the screening test was activated partial thromboplastin time (APTT); mean APTT calculated from the results reported by 4,029 labs was prolonged (clotting ratio = 1.44) with a large dispersion (coefficients of variation = 18.8%). APTT of the mixture 94B3 + normal plasma were performed by 2,698 laboratories. No correction of APTT was obtained (R = 1.36, Rosner index = 24) with a wide variation between reagents (17 < Rosner index < 39). Only 15% of the participants performed confirmatory tests; dilute tissue thromboplastin inhibition test (TTI) performed by 509 laboratories gave 75% positive results. Tests with an increased amount of phospholipids (Staclot LA and Staclot PNP from Diagnostica Stago), used by 116 and 72 laboratories, gave 88% and 61% positive results, respectively. A total of 1,862 laboratories made the diagnosis of LA. The majority of those who failed in diagnosing LA used an APTT reagent largely used in France, containing kaolin. This survey allowed Etalonorme to inform French biologists and draft an educational program for the biologic detection of LA and the identification of its mechanism of action.

  1. Determination of the moisture content of instant noodles: interlaboratory study.

    PubMed

    Hakoda, Akiko; Kasama, Hirotaka; Sakaida, Kenichi; Suzuki, Tadanao; Yasui, Akemi

    2006-01-01

    Determination of the moisture content of instant noodles, currently under discussion by the Codex Alimentarius Commission (CAC) requires 2 methods: one for fried noodles and the other for nonfried noodles. The method to determine the moisture content of fried noodles by drying at 105 degrees C for 2 h used in the Japanese Agricultural Standard (JAS) system of Japan can be applied to this purpose. In the present study, the JAS method for fried noodles was modified to be suitable for nonfried noodles by extending the drying time to 4 h. An interlaboratory study was conducted to evaluate interlaboratory performance statistics for these 2 methods. Ten participating laboratories each analyzed 5 test materials of fried and nonfried noodles as blind duplicates. After removal of outliers statistically, the repeatability (RSDr) and the reproducibility (RSD(R)) of these methods were 1.6-2.6 and 3.9-4.8% for fried noodles, and 0.3-1.5 and 1.3-2.9% for nonfried noodles, respectively.

  2. Comparison of bulk sediment and sediment elutriate toxicity testing methods

    EPA Science Inventory

    Elutriate bioassays are among numerous methods that exist for assessing the potential toxicity of sediments in aquatic systems. In this study, interlaboratory results were compared from 96-hour Ceriodaphnia dubia and Pimephales promelas static-renewal acute toxicity tests conduct...

  3. Use of allogeneic apheresis stem cell products as an interlaboratory proficiency challenge.

    PubMed

    Cooling, Laura; Roxbury, Kelly; Hoffmann, Sandra; DeBusscher, Joan; Kota, Usha; Goldstein, Steven; Davenport, Robertson

    2017-06-01

    AABB Standards requires that laboratories participate in a proficiency test (PT) program for critical analytes. Institutions can purchase commercial PT materials; however, PT can also be performed through interlaboratory exchange. We investigated the utility of allogeneic hematopoietic progenitor cell apheresis (HPC-A) products as an interlaboratory PT challenge for total nucleated cell count (TNC) and CD34 assessment. Three-year retrospective and comparative review of unrelated allogeneic HPC-A products received by the University of Michigan between January 2011 and December 2013. Internal TNC and CD34 count were compared to the external collecting facility by paired t test and linear regression. The absolute and percent difference between external and internal counts and 95% limits of agreeability (95% LA) were determined. Results were analyzed relative to donor center location (international, domestic), time zone (domestic), and calendar year. There was a strong correlation between internal and external TNC, regardless of donor center location or year. For CD34, there was a good correlation between centers (R = 0.88-0.91; slope = 0.95-0.98x) with a median difference of -1% (95% LA, -50%, +47%). This was considerably better than commercial PT challenges, which showed a persistent negative bias for absolute CD34 and CD3 counts. Allogeneic HPC-A products represent an interlaboratory PT exchange for all critical analytes, including TNC and CD34 count, cell viability, and sterility. Allogeneic HPC-A products, which are fresh and transported under validated conditions, are less subject to preanalytical variables that may impact commercial PT samples such as aliquoting and sample homogeneity, commercial additives, and sample stability during manufacturing and transport. © 2017 AABB.

  4. Interlaboratory comparison of three microbial source tracking quantitative polymerase chain reaction (qPCR) assays from fecal-source and environmental samples

    USGS Publications Warehouse

    Stelzer, Erin A.; Strickler, Kriston M.; Schill, William B.

    2012-01-01

    During summer and early fall 2010, 15 river samples and 6 fecal-source samples were collected in West Virginia. These samples were analyzed by three laboratories for three microbial source tracking (MST) markers: AllBac, a general fecal indicator; BacHum, a human-associated fecal indicator; and BoBac, a ruminant-associated fecal indicator. MST markers were analyzed by means of the quantitative polymerase chain reaction (qPCR) method. The aim was to assess interlaboratory precision when the three laboratories used the same MST marker and shared deoxyribonucleic acid (DNA) extracts of the samples, but different equipment, reagents, and analyst experience levels. The term assay refers to both the markers and the procedure differences listed above. Interlaboratory precision was best for all three MST assays when using the geometric mean absolute relative percent difference (ARPD) and Friedman's statistical test as a measure of interlaboratory precision. Adjustment factors (one for each MST assay) were calculated using results from fecal-source samples analyzed by all three laboratories and applied retrospectively to sample concentrations to account for differences in qPCR results among labs using different standards and procedures. Following the application of adjustment factors to qPCR results, ARPDs were lower; however, statistically significant differences between labs were still observed for the BacHum and BoBac assays. This was a small study and two of the MST assays had 52 percent of samples with concentrations at or below the limit of accurate quantification; hence, more testing could be done to determine if the adjustment factors would work better if the majority of sample concentrations were above the quantification limit.

  5. Validation of a two-generational reproduction test in Daphnia magna: An interlaboratory exercise.

    PubMed

    Barata, Carlos; Campos, Bruno; Rivetti, Claudia; LeBlanc, Gerald A; Eytcheson, Stephanie; McKnight, Stephanie; Tobor-Kaplon, Marysia; de Vries Buitenweg, Selinda; Choi, Suhyon; Choi, Jinhee; Sarapultseva, Elena I; Coutellec, Marie-Agnès; Coke, Maïra; Pandard, Pascal; Chaumot, Arnaud; Quéau, Hervé; Delorme, Nicolas; Geffard, Olivier; Martínez-Jerónimo, Fernando; Watanabe, Haruna; Tatarazako, Norihisa; Lopes, Isabel; Pestana, João L T; Soares, Amadeu M V M; Pereira, Cecilia Manuela; De Schamphelaere, Karel

    2017-02-01

    Effects observed within one generation disregard potential detrimental effects that may appear across generations. Previously we have developed a two generation Daphnia magna reproduction test using the OECD TG 211 protocol with a few amendments, including initiating the second generation with third brood neonates produced from first generation individuals. Here we showed the results of an inter-laboratory calibration exercise among 12 partners that aimed to test the robustness and consistency of a two generation Daphnia magna reproduction test. Pyperonyl butoxide (PBO) was used as a test compound. Following experiments, PBO residues were determined by TQD-LC/MS/MS. Chemical analysis denoted minor deviations of measured PBO concentrations in freshly prepared and old test solutions and between real and nominal concentrations in all labs. Other test conditions (water, food, D. magna clone, type of test vessel) varied across partners as allowed in the OECD test guidelines. Cumulative fecundity and intrinsic population growth rates (r) were used to estimate "No observed effect concentrations "NOEC using the solvent control as the control treatment. EC 10 and EC- 50 values were obtained regression analyses. Eleven of the twelve labs succeeded in meeting the OECD criteria of producing >60 offspring per female in control treatments during 21days in each of the two consecutive generations. Analysis of variance partitioning of cumulative fecundity indicated a relatively good performance of most labs with most of the variance accounted for by PBO (56.4%) and PBO by interlaboratory interactions (20.2%), with multigenerational effects within and across PBO concentrations explaining about 6% of the variance. EC 50 values for reproduction and population growth rates were on average 16.6 and 20.8% lower among second generation individuals, respectively. In summary these results suggest that the proposed assay is reproducible but cumulative toxicity in the second generation cannot reliably be detected with this assay. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Interlaboratory comparison of chemical analysis of uranium mononitride

    NASA Technical Reports Server (NTRS)

    Merkle, E. J.; Davis, W. F.; Halloran, J. T.; Graab, J. W.

    1974-01-01

    Analytical methods were established in which the critical variables were controlled, with the result that acceptable interlaboratory agreement was demonstrated for the chemical analysis of uranium mononitride. This was accomplished by using equipment readily available to laboratories performing metallurgical analyses. Agreement among three laboratories was shown to be very good for uranium and nitrogen. Interlaboratory precision of + or - 0.04 percent was achieved for both of these elements. Oxygen was determined to + or - 15 parts per million (ppm) at the 170-ppm level. The carbon determination gave an interlaboratory precision of + or - 46 ppm at the 320-ppm level.

  7. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PVmore » installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  8. Degradation in PV Encapsulation Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from the outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PVmore » installations was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  9. Degradation in PV Encapsulant Strength of Attachment: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    Reduced strength of attachment of the encapsulant resulting from outdoor environment, including ultraviolet (UV) radiation, may decrease photovoltaic (PV) module lifetime by enabling widespread corrosion of internal components. To date, few studies exist showing how the adhesion of PV components varies with environmental stress. We have conducted an interlaboratory experiment to provide an understanding that will be used to develop climatic specific module tests. Factors examined in the study included the UV light source (lamp type), temperature, and humidity to be proposed for use in accelerated aging tests. A poly (ethylene-co-vinyl acetate) (EVA) formulation often used in veteran PV installationsmore » was studied using a compressive shear test - to quantify the strength of attachment at the EVA/glass interface. Replicate laminated glass/polymer/glass coupon specimens were weathered at 12 institutions using a variety of indoor chambers or field aging. Shear strength, shear strain, and toughness were measured using a mechanical load-frame for the compressive shear test, with subsequent optical imaging and electron microscopy of the separated surfaces.« less

  10. Within-Subject Interlaboratory Variability of QuantiFERON-TB Gold In-Tube Tests

    DTIC Science & Technology

    2012-09-06

    QuantiFERONH-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection...viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test...release assays (IGRAs) are designed to detect both latent Mycobacterium tuberculosis infection (LTBI) and infections manifesting as active

  11. Development and Interlaboratory Study of a Liquid Chromatography Tandem Mass Spectrometric Methodfor the Determination of Multiple Mycotoxins inCereals Using Stable Isotope Dilution.

    PubMed

    Ye, Jin; Wu, Yu; Guo, Qilei; Lu, Meiling; Wang, Songshan; Xin, Yuanyuan; Xie, Gang; Zhang, Yan; Mariappan, Meena; Wang, Songxue

    2018-05-01

    An efficient, rapid, accurate, and cost-effective method based on stable isotope dilution and LC tandem MS was developed for the determination of multimycotoxins in cereals. The samples were extracted using acetonitrile-water-acetic acid (70 + 29 + 1, v/v/v), followed by dilution and centrifugation without any further cleanup. The mycotoxins were separated on a C18 column. Interference due to matrix effects was efficiently compensated for with [13C]-labeled stable isotope internal standards. The method demonstrated excellent linear relations, with regression coefficients above 0.999. Spiked recoveries at three different concentrations ranged from 80.9 to 115.9%, and RSDs were below 14% for all mycotoxins. The trueness of the method was also verified by participating in two proficiency tests, and satisfactory z-scores (|z| < 1.1) were obtained. In addition, an international interlaboratory study was organized to evaluate the methods. Eight laboratories characterized recovery, repeatability, and reproducibility studies in wheat, maize, and barley. The interlaboratory results were analyzed according to ISO 5725-2. Cochran and Grubbs tests were used to remove outliers. The mean recoveries of all 16 mycotoxins ranged from 87 to 111%. Repeatability, reproducibility, and Horwitz ratio values were 3.5-16.2, 5.4-33.6, and 0.16-1.65%, respectively. The results demonstrate that the method is reliable to determine multimycotoxins in cereals.

  12. Increased frequencies of aberrant sperm as indicators of mutagenic damage in mice.

    PubMed

    Soares, E R; Sheridan, W; Haseman, J K; Segall, M

    1979-02-01

    We have tested the effects of TEM in 3 strains of mice using the sperm morphology assay. In addition, we have made an attempt to evaluate this test system with respect to experimental design, statistical problems and possible interlaboratory differences. Treatment with TEM results in significant increases in the percent of abnormally shaped sperm. These increases are readily detectable in sperm treated as spermatocytes and spermatogonial stages. Our data indicate possible problems associated with inter-laboratory variation in slide analysis. We have found that despite the introduction of such sources of variation, our data were consistent with respect to the effects of TEM. Another area of concern in the sperm morphology test is the presence of "outlier" animals. In our study, such animals comprised 4% of the total number of animals considered. Statistical analysis of the slides from these animals have shown that this problem can be dealt with and that when recognized as such, "outliers" do not effect the outcome of the sperm morphology assay.

  13. 77 FR 29757 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-18

    ... Discharge Elimination System (NPDES) program, issue permits with conditions designed to ensure compliance... completion of a full inter-laboratory validation study designed to fully characterize the performance of...

  14. Interlaboratory Comparison Test as an Evaluation of Applicability of an Alternative Edible Oil Analysis by 1H NMR Spectroscopy.

    PubMed

    Zailer, Elina; Holzgrabe, Ulrike; Diehl, Bernd W K

    2017-11-01

    A proton (1H) NMR spectroscopic method was established for the quality assessment of vegetable oils. To date, several research studies have been published demonstrating the high potential of the NMR technique in lipid analysis. An interlaboratory comparison was organized with the following main objectives: (1) to evaluate an alternative analysis of edible oils by using 1H NMR spectroscopy; and (2) to determine the robustness and reproducibility of the method. Five different edible oil samples were analyzed by evaluating 15 signals (free fatty acids, peroxides, aldehydes, double bonds, and linoleic and linolenic acids) in each spectrum. A total of 21 NMR data sets were obtained from 17 international participant laboratories. The performance of each laboratory was assessed by their z-scores. The test was successfully passed by 90.5% of the participants. Results showed that NMR spectroscopy is a robust alternative method for edible oil analysis.

  15. Determination of the acid value of instant noodles: interlaboratory study.

    PubMed

    Hakoda, Akiko; Sakaida, Kenichi; Suzuki, Tadanao; Yasui, Akemi

    2006-01-01

    An interlaboratory study was performed to evaluate the method for determining the acid value of instant noodles, based on the Japanese Agricultural Standard (JAS), with extraction of lipid using petroleum ether at a volume of 100 mL to the test portion of 25 g. Thirteen laboratories participated and analyzed 5 test samples as blind duplicates. Statistical treatment revealed that the repeatability (RSDr) of acid value was <6.5%, and the reproducibility (RSDR) of acid value was <9.6%. The HorRat values (RSDR/predicted RSDR) were 1.2-1.8, where the RSDR and the predicted RSDR were obtained in terms of free fatty acids in the noodles per unit weight, using the equation [acid value = percent free fatty acids (as oleic) x 1.99] and the extracted lipid contents. This method was shown to have acceptable precision by the present study.

  16. Measuring the uncertainties of discharge measurements: interlaboratory experiments in hydrometry

    NASA Astrophysics Data System (ADS)

    Le Coz, Jérôme; Blanquart, Bertrand; Pobanz, Karine; Dramais, Guillaume; Pierrefeu, Gilles; Hauet, Alexandre; Despax, Aurélien

    2015-04-01

    Quantifying the uncertainty of streamflow data is key for hydrological sciences. The conventional uncertainty analysis based on error propagation techniques is restricted by the absence of traceable discharge standards and by the weight of difficult-to-predict errors related to the operator, procedure and measurement environment. Field interlaboratory experiments recently emerged as an efficient, standardized method to 'measure' the uncertainties of a given streamgauging technique in given measurement conditions. Both uncertainty approaches are compatible and should be developed jointly in the field of hydrometry. In the recent years, several interlaboratory experiments have been reported by different hydrological services. They involved different streamgauging techniques, including acoustic profilers (ADCP), current-meters and handheld radars (SVR). Uncertainty analysis was not always their primary goal: most often, testing the proficiency and homogeneity of instruments, makes and models, procedures and operators was the original motivation. When interlaboratory experiments are processed for uncertainty analysis, once outliers have been discarded all participants are assumed to be equally skilled and to apply the same streamgauging technique in equivalent conditions. A universal requirement is that all participants simultaneously measure the same discharge, which shall be kept constant within negligible variations. To our best knowledge, we were the first to apply the interlaboratory method for computing the uncertainties of streamgauging techniques, according to the authoritative international documents (ISO standards). Several specific issues arise due to the measurements conditions in outdoor canals and rivers. The main limitation is that the best available river discharge references are usually too uncertain to quantify the bias of the streamgauging technique, i.e. the systematic errors that are common to all participants in the experiment. A reference or a sensitivity analysis to the fixed parameters of the streamgauging technique remain very useful for estimating the uncertainty related to the (non quantified) bias correction. In the absence of a reference, the uncertainty estimate is referenced to the average of all discharge measurements in the interlaboratory experiment, ignoring the technique bias. Simple equations can be used to assess the uncertainty of the uncertainty results, as a function of the number of participants and of repeated measurements. The interlaboratory method was applied to several interlaboratory experiments on ADCPs and currentmeters mounted on wading rods, in streams of different sizes and aspects, with 10 to 30 instruments, typically. The uncertainty results were consistent with the usual expert judgment and highly depended on the measurement environment. Approximately, the expanded uncertainties (within the 95% probability interval) were ±5% to ±10% for ADCPs in good or poor conditions, and ±10% to ±15% for currentmeters in shallow creeks. Due to the specific limitations related to a slow measurement process and to small, natural streams, uncertainty results for currentmeters were more uncertain than for ADCPs, for which the site-specific errors were significantly evidenced. The proposed method can be applied to a wide range of interlaboratory experiments conducted in contrasted environments for different streamgauging techniques, in a standardized way. Ideally, an international open database would enhance the investigation of hydrological data uncertainties, according to the characteristics of the measurement conditions and procedures. Such a dataset could be used for implementing and validating uncertainty propagation methods in hydrometry.

  17. Interlaboratory trial for the measurement of total cobalt in equine urine and plasma by ICP-MS.

    PubMed

    Popot, Marie-Agnes; Ho, Emmie N M; Stojiljkovic, Natali; Bagilet, Florian; Remy, Pierre; Maciejewski, Pascal; Loup, Benoit; Chan, George H M; Hargrave, Sabine; Arthur, Rick M; Russo, Charlie; White, James; Hincks, Pamela; Pearce, Clive; Ganio, George; Zahra, Paul; Batty, David; Jarrett, Mark; Brooks, Lydia; Prescott, Lise-Anne; Bailly-Chouriberry, Ludovic; Bonnaire, Yves; Wan, Terence S M

    2017-09-01

    Cobalt is an essential mineral micronutrient and is regularly present in equine nutritional and feed supplements. Therefore, cobalt is naturally present at low concentrations in biological samples. The administration of cobalt chloride is considered to be blood doping and is thus prohibited. To control the misuse of cobalt, it was mandatory to establish an international threshold for cobalt in plasma and/or in urine. To achieve this goal, an international collaboration, consisting of an interlaboratory comparison between 5 laboratories for the urine study and 8 laboratories for the plasma study, has been undertaken. Quantification of cobalt in the biological samples was performed by inductively coupled plasma-mass spectrometry (ICP-MS). Ring tests were based on the analysis of 5 urine samples supplemented at concentrations ranging from 5 up to 500 ng/mL and 5 plasma samples spiked at concentrations ranging from 0.5 up to 25 ng/mL. The results obtained from the different laboratories were collected, compiled, and compared to assess the reproducibility and robustness of cobalt quantification measurements. The statistical approach for the ring test for total cobalt in urine was based on the determination of percentage deviations from the calculated means, while robust statistics based on the calculated median were applied to the ring test for total cobalt in plasma. The inter-laboratory comparisons in urine and in plasma were successful so that 97.6% of the urine samples and 97.5% of the plasma samples gave satisfactory results. Threshold values for cobalt in plasma and urine were established from data only obtained by laboratories involved in the ring test. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Comparison of Different Matrices as Potential Quality Control Samples for Neurochemical Dementia Diagnostics.

    PubMed

    Lelental, Natalia; Brandner, Sebastian; Kofanova, Olga; Blennow, Kaj; Zetterberg, Henrik; Andreasson, Ulf; Engelborghs, Sebastiaan; Mroczko, Barbara; Gabryelewicz, Tomasz; Teunissen, Charlotte; Mollenhauer, Brit; Parnetti, Lucilla; Chiasserini, Davide; Molinuevo, Jose Luis; Perret-Liaudet, Armand; Verbeek, Marcel M; Andreasen, Niels; Brosseron, Frederic; Bahl, Justyna M C; Herukka, Sanna-Kaisa; Hausner, Lucrezia; Frölich, Lutz; Labonte, Anne; Poirier, Judes; Miller, Anne-Marie; Zilka, Norbert; Kovacech, Branislav; Urbani, Andrea; Suardi, Silvia; Oliveira, Catarina; Baldeiras, Ines; Dubois, Bruno; Rot, Uros; Lehmann, Sylvain; Skinningsrud, Anders; Betsou, Fay; Wiltfang, Jens; Gkatzima, Olymbia; Winblad, Bengt; Buchfelder, Michael; Kornhuber, Johannes; Lewczuk, Piotr

    2016-03-01

    Assay-vendor independent quality control (QC) samples for neurochemical dementia diagnostics (NDD) biomarkers are so far commercially unavailable. This requires that NDD laboratories prepare their own QC samples, for example by pooling leftover cerebrospinal fluid (CSF) samples. To prepare and test alternative matrices for QC samples that could facilitate intra- and inter-laboratory QC of the NDD biomarkers. Three matrices were validated in this study: (A) human pooled CSF, (B) Aβ peptides spiked into human prediluted plasma, and (C) Aβ peptides spiked into solution of bovine serum albumin in phosphate-buffered saline. All matrices were tested also after supplementation with an antibacterial agent (sodium azide). We analyzed short- and long-term stability of the biomarkers with ELISA and chemiluminescence (Fujirebio Europe, MSD, IBL International), and performed an inter-laboratory variability study. NDD biomarkers turned out to be stable in almost all samples stored at the tested conditions for up to 14 days as well as in samples stored deep-frozen (at - 80°C) for up to one year. Sodium azide did not influence biomarker stability. Inter-center variability of the samples sent at room temperature (pooled CSF, freeze-dried CSF, and four artificial matrices) was comparable to the results obtained on deep-frozen samples in other large-scale projects. Our results suggest that it is possible to replace self-made, CSF-based QC samples with large-scale volumes of QC materials prepared with artificial peptides and matrices. This would greatly facilitate intra- and inter-laboratory QC schedules for NDD measurements.

  19. Standardization of reflectance measurements in dispersed organic matter: results of an exercise to improve interlaboratory agreement

    USGS Publications Warehouse

    Hackley, Paul C.; Araujo, Carla Viviane; Borrego, Angeles G.; Bouzinos, Antonis; Cardott, Brian; Cook, Alan C.; Eble, Cortland; Flores, Deolinda; Gentzis, Thomas; Gonçalves, Paula Alexandra; Filho, João Graciano Mendonça; Hámor-Vidó, Mária; Jelonek, Iwona; Kommeren, Kees; Knowles, Wayne; Kus, Jolanta; Mastalerz, Maria; Menezes, Taíssa Rêgo; Newman, Jane; Pawlewicz, Mark; Pickel, Walter; Potter, Judith; Ranasinghe, Paddy; Read, Harold; Reyes, Julito; Rodriguez, Genaro De La Rosa; de Souza, Igor Viegas Alves Fernandes; Suarez-Ruiz, Isabel; Sýkorová, Ivana; Valentine, Brett J.

    2015-01-01

    Vitrinite reflectance generally is considered the most robust thermal maturity parameter available for application to hydrocarbon exploration and petroleum system evaluation. However, until 2011 there was no standardized methodology available to provide guidelines for vitrinite reflectance measurements in shale. Efforts to correct this deficiency resulted in publication of ASTM D7708: Standard test method for microscopical determination of the reflectance of vitrinite dispersed in sedimentary rocks. In 2012-2013, an interlaboratory exercise was conducted to establish precision limits for the D7708 measurement technique. Six samples, representing a wide variety of shale, were tested in duplicate by 28 analysts in 22 laboratories from 14 countries. Samples ranged from immature to overmature (0.31-1.53% Ro), from organic-lean to organic-rich (1-22 wt.% total organic carbon), and contained Type I (lacustrine), Type II (marine), and Type III (terrestrial) kerogens. Repeatability limits (maximum difference between valid repetitive results from same operator, same conditions) ranged from 0.03-0.11% absolute reflectance, whereas reproducibility limits (maximum difference between valid results obtained on same test material by different operators, different laboratories) ranged from 0.12-0.54% absolute reflectance. Repeatability and reproducibility limits degraded consistently with increasing maturity and decreasing organic content. However, samples with terrestrial kerogens (Type III) fell off this trend, showing improved levels of reproducibility due to higher vitrinite content and improved ease of identification. Operators did not consistently meet the reporting requirements of the test method, indicating that a common reporting template is required to improve data quality. The most difficult problem encountered was the petrographic distinction of solid bitumens and low-reflecting inert macerals from vitrinite when vitrinite occurred with reflectance ranges overlapping the other components. Discussion among participants suggested this problem could not be easily corrected via kerogen concentration or solvent extraction and is related to operator training and background. No statistical difference in mean reflectance was identified between participants reporting bitumen reflectance vs. vitrinite reflectance vs. a mixture of bitumen and vitrinite reflectance values, suggesting empirical conversion schemes should be treated with caution. Analysis of reproducibility limits obtained during this exercise in comparison to reproducibility limits from historical interlaboratory exercises suggests use of a common methodology (D7708) improves interlaboratory precision. Future work will investigate opportunities to improve reproducibility in high maturity, organic-lean shale varieties.

  20. Comparisons of interlaboratory swellometer testing of two water-repellent preservative formulations for millwork

    Treesearch

    Elmer L. Schmidt; Timothy P. Murphy; Charles N. Cheeks; Alan S. Ross; T. S. (Eugene) Chiu; R. Sam Williams

    2002-01-01

    Water-repellency of preservative formulations used in the millwork industry has long been evaluated by measurement of the dimensional changes in wood treated and then submerged in water according to guidelines published by the millwork industry. Perceptions that this swellometer test was highly variable led to a round-robin test of one solvent-borne and one waterborne...

  1. INTER LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON

    DTIC Science & Technology

    2018-03-26

    HELMET BLUNT IMPACT TEST METHOD COMPARISON by Tony J. Kayhart Charles A. Hewitt and Jonathan Cyganik March 2018 Final...Report March 2016 – August 2017 Approved for public release; distribution is unlimited U.S. Army Natick Soldier Research ...INTER-LABORATORY COMBAT HELMET BLUNT IMPACT TEST METHOD COMPARISON 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  2. Examination of a size-change test for photovoltaic encapsulation materials

    NASA Astrophysics Data System (ADS)

    Miller, David C.; Gu, Xiaohong; Ji, Liang; Kelly, George; Nickel, Nichole; Norum, Paul; Shioda, Tsuyoshi; Tamizhmani, Govindasamy; Wohlgemuth, John H.

    2012-10-01

    We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International Electrotechnical Commission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sand substrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/-5°C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). The test procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/-5% between laboratories.

  3. Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples.

    PubMed

    Berlinger, Balazs; Harper, Martin

    2018-02-01

    There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.

  4. Multielement trace determination in SiC powders: assessment of interlaboratory comparisons aimed at the validation and standardization of analytical procedures with direct solid sampling based on ETV ICP OES and DC arc OES.

    PubMed

    Matschat, Ralf; Hassler, Jürgen; Traub, Heike; Dette, Angelika

    2005-12-01

    The members of the committee NMP 264 "Chemical analysis of non-oxidic raw and basic materials" of the German Standards Institute (DIN) have organized two interlaboratory comparisons for multielement determination of trace elements in silicon carbide (SiC) powders via direct solid sampling methods. One of the interlaboratory comparisons was based on the application of inductively coupled plasma optical emission spectrometry with electrothermal vaporization (ETV ICP OES), and the other on the application of optical emission spectrometry with direct current arc (DC arc OES). The interlaboratory comparisons were organized and performed in the framework of the development of two standards related to "the determination of mass fractions of metallic impurities in powders and grain sizes of ceramic raw and basic materials" by both methods. SiC powders were used as typical examples of this category of material. The aim of the interlaboratory comparisons was to determine the repeatability and reproducibility of both analytical methods to be standardized. This was an important contribution to the practical applicability of both draft standards. Eight laboratories participated in the interlaboratory comparison with ETV ICP OES and nine in the interlaboratory comparison with DC arc OES. Ten analytes were investigated by ETV ICP OES and eleven by DC arc OES. Six different SiC powders were used for the calibration. The mass fractions of their relevant trace elements were determined after wet chemical digestion. All participants followed the analytical requirements described in the draft standards. In the calculation process, three of the calibration materials were used successively as analytical samples. This was managed in the following manner: the material that had just been used as the analytical sample was excluded from the calibration, so the five other materials were used to establish the calibration plot. The results from the interlaboratory comparisons were summarized and used to determine the repeatability and the reproducibility (expressed as standard deviations) of both methods. The calculation was carried out according to the related standard. The results are specified and discussed in this paper, as are the optimized analytical conditions determined and used by the authors of this paper. For both methods, the repeatability relative standard deviations were <25%, usually ~10%, and the reproducibility relative standard deviations were <35%, usually ~15%. These results were regarded as satifactory for both methods intended for rapid analysis of materials for which decomposition is difficult and time-consuming. Also described are some results from an interlaboratory comparison used to certify one of the materials that had been previously used for validation in both interlaboratory comparisons. Thirty laboratories (from eight countries) participated in this interlaboratory comparison for certification. As examples, accepted results are shown from laboratories that used ETV ICP OES or DC arc OES and had performed calibrations by using solutions or oxides, respectively. The certified mass fractions of the certified reference materials were also compared with the mass fractions determined in the interlaboratory comparisons performed within the framework of method standardization. Good agreement was found for most of the analytes.

  5. A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY

    EPA Science Inventory

    Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...

  6. Progress in Quantitative Viral Load Testing: Variability and Impact of the WHO Quantitative International Standards

    PubMed Central

    Sun, Y.; Tang, L.; Procop, G. W.; Hillyard, D. R.; Young, S. A.; Caliendo, A. M.

    2016-01-01

    ABSTRACT It has been hoped that the recent availability of WHO quantitative standards would improve interlaboratory agreement for viral load testing; however, insufficient data are available to evaluate whether this has been the case. Results from 554 laboratories participating in proficiency testing surveys for quantitative PCR assays of cytomegalovirus (CMV), Epstein-Barr virus (EBV), BK virus (BKV), adenovirus (ADV), and human herpesvirus 6 (HHV6) were evaluated to determine overall result variability and then were stratified by assay manufacturer. The impact of calibration to international units/ml (CMV and EBV) on variability was also determined. Viral loads showed a high degree of interlaboratory variability for all tested viruses, with interquartile ranges as high as 1.46 log10 copies/ml and the overall range for a given sample up to 5.66 log10 copies/ml. Some improvement in result variability was seen when international units were adopted. This was particularly the case for EBV viral load results. Variability in viral load results remains a challenge across all viruses tested here; introduction of international quantitative standards may help reduce variability and does so more or less markedly for certain viruses. PMID:27852673

  7. Infrared spectral normal emittance/emissivity comparison

    NASA Astrophysics Data System (ADS)

    Hanssen, L.; Wilthan, B.; Filtz, J.-R.; Hameury, J.; Girard, F.; Battuello, M.; Ishii, J.; Hollandt, J.; Monte, C.

    2016-01-01

    The National Measurement Institutes (NMIs) of the United States, Germany, France, Italy and Japan, have joined in an inter-laboratory comparison of their infrared spectral emittance scales. This action is part of a series of supplementary inter-laboratory comparisons (including thermal conductivity and thermal diffusivity) sponsored by the Consultative Committee on Thermometry (CCT) Task Group on Thermophysical Quantities (TG-ThQ). The objective of this collaborative work is to strengthen the major operative National Measurement Institutes' infrared spectral emittance scales and consequently the consistency of radiative properties measurements carried out worldwide. The comparison has been performed over a spectral range of 2 μm to 14 μm, and a temperature range from 23 °C to 800 °C. Artefacts included in the comparison are potential standards: oxidized Inconel, boron nitride, and silicon carbide. The measurement instrumentation and techniques used for emittance scales are unique for each NMI, including the temperature ranges covered as well as the artefact sizes required. For example, all three common types of spectral instruments are represented: dispersive grating monochromator, Fourier transform and filter-based spectrometers. More than 2000 data points (combinations of material, wavelength and temperature) were compared. Ninety-eight percent (98%) of the data points were in agreement, with differences to weighted mean values less than the expanded uncertainties calculated from the individual NMI uncertainties and uncertainties related to the comparison process. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  8. Interlaboratory discrepancy of antigenuria results in 2 patients with AIDS and histoplasmosis.

    PubMed

    McKinsey, David S; McKinsey, Joel P; Northcutt, Noelle; Sarria, Juan C

    2009-01-01

    Histoplasma polysaccharide antigen testing is used routinely to diagnose histoplasmosis. At least 3 antigen tests are commercially available. Controversy exists about the relative accuracy of these tests. We report 2 patients with AIDS and culture-confirmed Histoplasma capsulatum meningitis from whom discrepant Histoplasma polysaccharide antigen results were obtained from different laboratories and discuss the potential clinical implications of these results.

  9. Interlaboratory Comparison of Quantitative PCR Test Results for Dehalococcoides

    EPA Science Inventory

    Quantitative PCR (qPCR) techniques have been widely used to measure Dehalococcoides (Dhc) DNA in the groundwater at field sites for several years. Interpretation of these data may be complicated when different laboratories using alternate methods conduct the analysis. An...

  10. Interlaboratory Variability of Slip Coefficient Testing for Bridge Coatings

    DOT National Transportation Integrated Search

    2014-12-01

    All steel bridge systems need some type of a corrosion protection scheme to ensure a serviceable life. The most common approach is to use a multilayered paint system with a zinc-rich primer. In addition to corrosion performance, other factors need to...

  11. Inter-laboratory comparison study on measuring semi-volatile organic chemicals in standards and air samples.

    PubMed

    Su, Yushan; Hung, Hayley

    2010-11-01

    Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences. 2010. Published by Elsevier Ltd. All rights reserved.

  12. An interlaboratory study to test instrument performance of hydrogen dual-inlet isotope-ratio mass spectrometers

    USGS Publications Warehouse

    Brand, Willi A.; Coplen, T.B.

    2001-01-01

    An interlaboratory comparison of forty isotope-ratio mass spectrometers of different ages from several vendors has been performed to test 2H/1H performance with hydrogen gases of three different isotopic compositions. The isotope-ratio results (unsufficiently corrected for H3+ contribution to the m/z = 3 collector, uncorrected for valve leakage in the change-over valves, etc.) expressed relative to one of these three gases covered a wide range of values: -630??? to -790??? for the second gas and -368??? to -462??? for the third gas. After normalizing the isotopic abundances of these test gases (linearly adjusting the ?? values so that the gases with the lowest and highest 2H content were identical for all laboratories), the standard deviation of the 40 measurements of the intermediate gas was a remarkably low 0.85???. It is concluded that the use of scaling factors is mandatory for providing accurate internationally comparable isotope-abundance values. Linear scaling for the isotope-ratio scales of gaseous hydrogen mass spectrometers is completely adequate. ?? Springer-Verlag 2001.

  13. Development and initial evaluation of a reconstituted water formulation that better represents natural waters(poster)

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  14. Development and Initial Evaluation of a Reconstituted Water Formulation that Better Represents Natural Waters

    EPA Science Inventory

    The use of reconstituted waters is deeply entrenched in many standardized aquatic toxicity testing protocols. The primary appeal of reconstituted waters is inter-laboratory comparability, such that experiments performed in different laboratories can be conducted in (nominally) id...

  15. Use of the rapid immersion test to evaluate the efficacy of admixtures to mitigate alkali-silica reactivity.

    DOT National Transportation Integrated Search

    1996-01-01

    The Federal Highway Administration (FHWA) is conducting an interlaboratory study to validate certain findings in the Strategic Highway Research Program (SHRP) C-343 report on alkali-silica reactivity. This paper reports the Virginia Transportation Re...

  16. Collaborative analysis of wheat endosperm compressive material properties

    USDA-ARS?s Scientific Manuscript database

    The objective measurement of cereal endosperm texture, for wheat (Triticum L.) in particular, is relevant to the milling, processing and utilization of grain. The objective of this study was to evaluate the inter-laboratory results of compression failure testing of wheat endosperm specimens of defi...

  17. Determination of Minor and Trace Metals in Aluminum and Aluminum Alloys by ICP-AES; Evaluation of the Uncertainty and Limit of Quantitation from Interlaboratory Testing.

    PubMed

    Uemoto, Michihisa; Makino, Masanori; Ota, Yuji; Sakaguchi, Hiromi; Shimizu, Yukari; Sato, Kazuhiro

    2018-01-01

    Minor and trace metals in aluminum and aluminum alloys have been determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) as an interlaboratory testing toward standardization. The trueness of the measured data was successfully investigated to improve the analytical protocols, using certified reference materials of aluminum. Their precision could also be evaluated, feasible to estimate the uncertainties separately. The accuracy (trueness and precision) of the data were finally in good agreement with the certified values and assigned uncertainties. Repeated measurements of aluminum solutions with different concentrations of the analytes revealed the relative standard deviations of the measurements with concentrations, thus enabling their limits of quantitation. They differed separately and also showed slightly higher values with an aluminum matrix than those without one. In addition, the upper limit of the detectable concentration of silicon with simple acid digestion was estimated to be 0.03 % in the mass fraction.

  18. Evaluation of platelet adhesion and activation on polymers: Round-robin study to assess inter-center variability.

    PubMed

    Braune, S; Sperling, C; Maitz, M F; Steinseifer, U; Clauser, J; Hiebl, B; Krajewski, S; Wendel, H P; Jung, F

    2017-10-01

    The regulatory agencies provide recommendations rather than protocols or standard operation procedures for the hemocompatibility evaluation of novel materials e.g. for cardiovascular applications. Thus, there is a lack of specifications with regard to test setups and procedures. As a consequence, laboratories worldwide perform in vitro assays under substantially different test conditions, so that inter-laboratory and inter-study comparisons are impossible. Here, we report about a prospective, randomized and double-blind multicenter trial which demonstrates that standardization of in vitro test protocols allows a reproducible assessment of platelet adhesion and activation from fresh human platelet rich plasma as possible indicators of the thrombogenicity of cardiovascular implants. Standardization of the reported static in vitro setup resulted in a laboratory independent scoring of the following materials: poly(dimethyl siloxane) (PDMS), poly(ethylene terephthalate) (PET) and poly(tetrafluoro ethylene) (PTFE). The results of this in vitro study provide evidence that inter-laboratory and inter-study comparisons can be achieved for the evaluation of the adhesion and activation of platelets on blood-contacting biomaterials by stringent standardization of test protocols. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Development of micro-electrode array based tests for neurotoxicity: assessment of interlaboratory reproducibility with neuroactive chemicals

    EPA Science Inventory

    Neuronal assemblies within the Central Nervous System (CNS) produce spontaneous or stimulus-evoked electrophysiological activity that can be monitored and quantified in terms of action potential patterns. Such patterns provide a sensitive endpoint to detect effects of chemicals, ...

  20. Development and inter-laboratory assessment of droplet digital PCR assays for multiplex quantification of 15 genetically modified soybean lines.

    PubMed

    Košir, Alexandra Bogožalec; Spilsberg, Bjørn; Holst-Jensen, Arne; Žel, Jana; Dobnik, David

    2017-08-17

    Quantification of genetically modified organisms (GMOs) in food and feed products is often required for their labelling or for tolerance thresholds. Standard-curve-based simplex quantitative polymerase chain reaction (qPCR) is the prevailing technology, which is often combined with screening analysis. With the rapidly growing number of GMOs on the world market, qPCR analysis becomes laborious and expensive. Innovative cost-effective approaches are therefore urgently needed. Here, we report the development and inter-laboratory assessment of multiplex assays to quantify GMO soybean using droplet digital PCR (ddPCR). The assays were developed to facilitate testing of foods and feed for compliance with current GMO regulations in the European Union (EU). Within the EU, the threshold for labelling is 0.9% for authorised GMOs per ingredient. Furthermore, the EU has set a technical zero tolerance limit of 0.1% for certain unauthorised GMOs. The novel multiplex ddPCR assays developed target 11 GMO soybean lines that are currently authorised, and four that are tolerated, pending authorisation in the EU. Potential significant improvements in cost efficiency are demonstrated. Performance was assessed for the critical parameters, including limits of detection and quantification, and trueness, repeatability, and robustness. Inter-laboratory performance was also determined on a number of proficiency programme and real-life samples.

  1. Harmonizing lipidomics: NIST interlaboratory comparison exercise for lipidomics using SRM 1950-Metabolites in Frozen Human Plasma.

    PubMed

    Bowden, John A; Heckert, Alan; Ulmer, Candice Z; Jones, Christina M; Koelmel, Jeremy P; Abdullah, Laila; Ahonen, Linda; Alnouti, Yazen; Armando, Aaron M; Asara, John M; Bamba, Takeshi; Barr, John R; Bergquist, Jonas; Borchers, Christoph H; Brandsma, Joost; Breitkopf, Susanne B; Cajka, Tomas; Cazenave-Gassiot, Amaury; Checa, Antonio; Cinel, Michelle A; Colas, Romain A; Cremers, Serge; Dennis, Edward A; Evans, James E; Fauland, Alexander; Fiehn, Oliver; Gardner, Michael S; Garrett, Timothy J; Gotlinger, Katherine H; Han, Jun; Huang, Yingying; Neo, Aveline Huipeng; Hyötyläinen, Tuulia; Izumi, Yoshihiro; Jiang, Hongfeng; Jiang, Houli; Jiang, Jiang; Kachman, Maureen; Kiyonami, Reiko; Klavins, Kristaps; Klose, Christian; Köfeler, Harald C; Kolmert, Johan; Koal, Therese; Koster, Grielof; Kuklenyik, Zsuzsanna; Kurland, Irwin J; Leadley, Michael; Lin, Karen; Maddipati, Krishna Rao; McDougall, Danielle; Meikle, Peter J; Mellett, Natalie A; Monnin, Cian; Moseley, M Arthur; Nandakumar, Renu; Oresic, Matej; Patterson, Rainey; Peake, David; Pierce, Jason S; Post, Martin; Postle, Anthony D; Pugh, Rebecca; Qiu, Yunping; Quehenberger, Oswald; Ramrup, Parsram; Rees, Jon; Rembiesa, Barbara; Reynaud, Denis; Roth, Mary R; Sales, Susanne; Schuhmann, Kai; Schwartzman, Michal Laniado; Serhan, Charles N; Shevchenko, Andrej; Somerville, Stephen E; St John-Williams, Lisa; Surma, Michal A; Takeda, Hiroaki; Thakare, Rhishikesh; Thompson, J Will; Torta, Federico; Triebl, Alexander; Trötzmüller, Martin; Ubhayasekera, S J Kumari; Vuckovic, Dajana; Weir, Jacquelyn M; Welti, Ruth; Wenk, Markus R; Wheelock, Craig E; Yao, Libin; Yuan, Min; Zhao, Xueqing Heather; Zhou, Senlin

    2017-12-01

    As the lipidomics field continues to advance, self-evaluation within the community is critical. Here, we performed an interlaboratory comparison exercise for lipidomics using Standard Reference Material (SRM) 1950-Metabolites in Frozen Human Plasma, a commercially available reference material. The interlaboratory study comprised 31 diverse laboratories, with each laboratory using a different lipidomics workflow. A total of 1,527 unique lipids were measured across all laboratories and consensus location estimates and associated uncertainties were determined for 339 of these lipids measured at the sum composition level by five or more participating laboratories. These evaluated lipids detected in SRM 1950 serve as community-wide benchmarks for intra- and interlaboratory quality control and method validation. These analyses were performed using nonstandardized laboratory-independent workflows. The consensus locations were also compared with a previous examination of SRM 1950 by the LIPID MAPS consortium. While the central theme of the interlaboratory study was to provide values to help harmonize lipids, lipid mediators, and precursor measurements across the community, it was also initiated to stimulate a discussion regarding areas in need of improvement. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.

  2. Comet assay in reconstructed 3D human epidermal skin models--investigation of intra- and inter-laboratory reproducibility with coded chemicals.

    PubMed

    Reus, Astrid A; Reisinger, Kerstin; Downs, Thomas R; Carr, Gregory J; Zeller, Andreas; Corvi, Raffaella; Krul, Cyrille A M; Pfuhler, Stefan

    2013-11-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure.

  3. Inter-laboratory exercise on antibiotic drugs analysis in aqueous samples.

    PubMed

    Roig, B; Brogat, M; Mompelat, S; Leveque, J; Cadiere, A; Thomas, O

    2012-08-30

    An inter-laboratory exercise was organized under the PHARMAS EU project, by the Advanced School of Public Health (EHESP), in order to evaluate the performances of analytical methods for the measurement of antibiotics in waters (surface and tap). This is the first time such an exercise on antibiotics has been organized in Europe, using different kinds of analytical methods and devices. In this exercise thirteen laboratories from five countries (Canada, France, Italy, the Netherlands and Portugal) participated, and a total number of 78 samples were distributed. During the exercise, 2 testing samples (3 bottles of each) prepared from tap water and river water, respectively, spiked with antibiotics, were sent to participants and analyzed over a period of one month. A final number of 77 (98.7%) testing samples were considered. Depending on substances studied by each participant, 305 values in duplicate were collected, with the results for each sample being expressed as the target concentration. A statistical study was initiated using 611 results. The mean value, standard deviation, coefficient of variation, standard uncertainty of the mean, median, the minimum and maximum values of each series as well as the 95% confidence interval were obtained from each participant laboratory. In this exercise, 36 results (6% of accounted values) were outliers according to the distribution over the median (box plot). The outlier results were excluded. In order to establish the stability of testing samples in the course of the exercise, differences between variances obtained for every type of sample at different intervals were evaluated. The results showed no representative variations and it can be considered that all samples were stable during the exercise. The goals of this inter-laboratory study were to assess results variability when analysis is conducted by different laboratories, to evaluate the influence of different matrix samples, and to determine the rate at which participating laboratories successfully completed the tests initiated. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Comet assay in reconstructed 3D human epidermal skin models—investigation of intra- and inter-laboratory reproducibility with coded chemicals

    PubMed Central

    Pfuhler, Stefan

    2013-01-01

    Reconstructed 3D human epidermal skin models are being used increasingly for safety testing of chemicals. Based on EpiDerm™ tissues, an assay was developed in which the tissues were topically exposed to test chemicals for 3h followed by cell isolation and assessment of DNA damage using the comet assay. Inter-laboratory reproducibility of the 3D skin comet assay was initially demonstrated using two model genotoxic carcinogens, methyl methane sulfonate (MMS) and 4-nitroquinoline-n-oxide, and the results showed good concordance among three different laboratories and with in vivo data. In Phase 2 of the project, intra- and inter-laboratory reproducibility was investigated with five coded compounds with different genotoxicity liability tested at three different laboratories. For the genotoxic carcinogens MMS and N-ethyl-N-nitrosourea, all laboratories reported a dose-related and statistically significant increase (P < 0.05) in DNA damage in every experiment. For the genotoxic carcinogen, 2,4-diaminotoluene, the overall result from all laboratories showed a smaller, but significant genotoxic response (P < 0.05). For cyclohexanone (CHN) (non-genotoxic in vitro and in vivo, and non-carcinogenic), an increase compared to the solvent control acetone was observed only in one laboratory. However, the response was not dose related and CHN was judged negative overall, as was p-nitrophenol (p-NP) (genotoxic in vitro but not in vivo and non-carcinogenic), which was the only compound showing clear cytotoxic effects. For p-NP, significant DNA damage generally occurred only at doses that were substantially cytotoxic (>30% cell loss), and the overall response was comparable in all laboratories despite some differences in doses tested. The results of the collaborative study for the coded compounds were generally reproducible among the laboratories involved and intra-laboratory reproducibility was also good. These data indicate that the comet assay in EpiDerm™ skin models is a promising model for the safety assessment of compounds with a dermal route of exposure. PMID:24150594

  5. Interlaboratory Collaborations in the Undergraduate Setting

    ERIC Educational Resources Information Center

    Megehee, Elise G.; Hyslop, Alison G.; Rosso, Richard J.

    2005-01-01

    A novel approach to cross-disciplinary and group learning, known as interlaboratory collaborations, was developed. The method mimics an industrial or research setting, fosters teamwork, and emphasizes the importance of good communication skills in the sciences.

  6. Inter-laboratory trial of a standardized sediment contact test with the aquatic plant Myriophyllum aquaticum (ISO 16191).

    PubMed

    Feiler, Ute; Ratte, Monika; Arts, Gertie; Bazin, Christine; Brauer, Frank; Casado, Carmen; Dören, Laszlo; Eklund, Britta; Gilberg, Daniel; Grote, Matthias; Gonsior, Guido; Hafner, Christoph; Kopf, Willi; Lemnitzer, Bernd; Liedtke, Anja; Matthias, Uwe; Okos, Ewa; Pandard, Pascal; Scheerbaum, Dirk; Schmitt-Jansen, Mechthild; Stewart, Kathleen; Teodorovic, Ivana; Wenzel, Andrea; Pluta, Hans-Jürgen

    2014-03-01

    A whole-sediment toxicity test with Myriophyllum aquaticum has been developed by the German Federal Institute of Hydrology and standardized within the International Organization for Standardization (ISO; ISO 16191). An international ring-test was performed to evaluate the precision of the test method. Four sediments (artificial, natural) were tested. Test duration was 10 d, and test endpoint was inhibition of growth rate (r) based on fresh weight data. Eighteen of 21 laboratories met the validity criterion of r ≥ 0.09 d(-1) in the control. Results from 4 tests that did not conform to test-performance criteria were excluded from statistical evaluation. The inter-laboratory variability of growth rates (20.6%-25.0%) and inhibition (26.6%-39.9%) was comparable with the variability of other standardized bioassays. The mean test-internal variability of the controls was low (7% [control], 9.7% [solvent control]), yielding a high discriminatory power of the given test design (median minimum detectable differences [MDD] 13% to 15%). To ensure these MDDs, an additional validity criterion of CV ≤ 15% of the growth rate in the controls was recommended. As a positive control, 90 mg 3,5-dichlorophenol/kg sediment dry mass was tested. The range of the expected growth inhibition was proposed to be 35 ± 15%. The ring test results demonstrated the reliability of the ISO 16191 toxicity test and its suitability as a tool to assess the toxicity of sediment and dredged material. © 2013 SETAC.

  7. OECD validation study to assess intra- and inter-laboratory reproducibility of the zebrafish embryo toxicity test for acute aquatic toxicity testing.

    PubMed

    Busquet, François; Strecker, Ruben; Rawlings, Jane M; Belanger, Scott E; Braunbeck, Thomas; Carr, Gregory J; Cenijn, Peter; Fochtman, Przemyslaw; Gourmelon, Anne; Hübler, Nicole; Kleensang, André; Knöbel, Melanie; Kussatz, Carola; Legler, Juliette; Lillicrap, Adam; Martínez-Jerónimo, Fernando; Polleichtner, Christian; Rzodeczko, Helena; Salinas, Edward; Schneider, Katharina E; Scholz, Stefan; van den Brandhof, Evert-Jan; van der Ven, Leo T M; Walter-Rohde, Susanne; Weigt, Stefan; Witters, Hilda; Halder, Marlies

    2014-08-01

    The OECD validation study of the zebrafish embryo acute toxicity test (ZFET) for acute aquatic toxicity testing evaluated the ZFET reproducibility by testing 20 chemicals at 5 different concentrations in 3 independent runs in at least 3 laboratories. Stock solutions and test concentrations were analytically confirmed for 11 chemicals. Newly fertilised zebrafish eggs (20/concentration and control) were exposed for 96h to chemicals. Four apical endpoints were recorded daily as indicators of acute lethality: coagulation of the embryo, lack of somite formation, non-detachment of the tail bud from the yolk sac and lack of heartbeat. Results (LC50 values for 48/96h exposure) show that the ZFET is a robust method with a good intra- and inter-laboratory reproducibility (CV<30%) for most chemicals and laboratories. The reproducibility was lower (CV>30%) for some very toxic or volatile chemicals, and chemicals tested close to their limit of solubility. The ZFET is now available as OECD Test Guideline 236. Considering the high predictive capacity of the ZFET demonstrated by Belanger et al. (2013) in their retrospective analysis of acute fish toxicity and fish embryo acute toxicity data, the ZFET is ready to be considered for acute fish toxicity for regulatory purposes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  8. THE DETERMINATION OF TOTAL ORGANIC HALIDE IN WATER: AN INTERLABORATORY COMPARATIVE STUDY OF TWO METHODS

    EPA Science Inventory

    Total organic halide (TOX) analyzers are commonly used to measure the amount of dissolved halogenated organic byproducts in disinfected waters. Because of the lack of information on the identity of disinfection byproducts, rigorous testing of the dissolved organic halide (DOX) pr...

  9. INTERLABORATORY STUDY OF THE COLD VAPOR TECHNIQUE FOR TOTAL MERCURY IN WATER

    EPA Science Inventory

    The American Society for Testing and Materials (ASTM) and the U.S. Environmental Protection Agency (EPA) conducted a joint study of the cold vapor technique for total mercury in water, before formal acceptance of the method by each organization. The method employs an acid-permang...

  10. Workgroup for Hydraulic laboratory Testing and Verification of Hydroacoustic Instrumentation

    USGS Publications Warehouse

    Fulford, Janice M.; Armstrong, Brandy N.; Thibodeaux, Kirk G.

    2015-01-01

    An international workgroup was recently formed for hydraulic laboratory testing and verification of hydroacoustic instrumentation used for water velocity measurements. The activities of the workgroup have included one face to face meeting, conference calls and an inter-laboratory exchange of two acoustic meters among participating laboratories. Good agreement was found among four laboratories at higher tow speeds and poorer agreement at the lowest tow speed.

  11. A multilaboratory peer assessment quality assurance program-based evaluation of anticardiolipin antibody, and beta2-glycoprotein I antibody testing.

    PubMed

    Favaloro, Emmanuel J; Wong, Richard C W; Silvestrini, Roger; McEvoy, Robert; Jovanovich, Susan; Roberts-Thomson, Peter

    2005-02-01

    We evaluated the performance of anticardiolipin (aCL) and beta2-glycoprotein I (beta2-GPI) antibody assays through a large external quality assurance program. Data from the 2002 cycle of the Royal College of Pathologists of Australasia Quality Assurance Program (RCPA QAP) were analyzed for variation in reported numerical values and semiquantitative results or interpretations according to method type or group and in conjunction with available clinical data. High interlaboratory variation in numerical results and notable method-based variation, combined with a general lack of consensus in semiquantitative reporting, continues to be observed. Numerical results from cross-laboratory testing of 12 serum samples (for immunoglobulin G [IgG]-aCL, IgM-aCL, and IgG-beta2-GPI) yielded interlaboratory coefficients of variation (CVs) that were higher than 50% in six of 12 (50%) specimens for IgG-aCL, and 12 of 12 (100%) specimens for IgM-aCL and IgG-beta2-GPI. Semiquantitative reporting also varied considerably, with total (100%) consensus occurring in only four of 36 (11%) occasions. General consensus (where > 90% of participating laboratories agreed that a given serum sample gave a result of either negative or positive) was only obtained on 13 of 36 (36%) occasions. Variation in results between different method types or groups were also present, resulting in potential biasing of the RCPA QAP-defined target results by the large number of laboratories using the dominant aCL assays. Finally, laboratory findings frequently did not agree with the available clinical information. In conclusion, in a large proportion of specimens from the 2002 RCPA QAP cycle, laboratories could not agree on whether a serum sample tested was aCL-positive or aCL-negative, or beta2-GPI-positive or beta2-GPI-negative. Despite prior attempts to improve the standardization of testing and reporting practices, laboratory testing for aCL and anti-beta2-GPI still demonstrates significant interlaboratory and intermethod variation, which needs to be taken into account for the clinical interpretation of test results, especially those from different laboratories.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindahl, P.C.

    A proposed American Society for Testing and Materials (ASTM) method for the determination of arsenic and selenium content in coal has been used and evaluated in the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) as part of an interlaboratory study. Coal is conducted with Eschka's mixture (MgO + Na/sub 2/CO/sub 3/), followed by determination of the aresnic and selenium content by hydride generation/atomic absorption spectrophotometry. The method was evaluated on a series of coals, including two National Bureau of Standards-Standards Reference Material (NBS-SRM) coals and twelve ASTM coal samples. Comparison of ACL/ANL arsenic and selenium data for themore » suite of coal analyzed showed excellent agreement with certified values for the NBS-SRM coals and with interlaboratory data from five other laboratories for the ASTM coals. 11 refs., 3 figs., 6 tabs.« less

  13. Interlaboratory studies with the Chinese hamster V79 cell metabolic cooperation assay to detect tumor-promoting agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bohrman, J.S.; Burg, J.R.; Elmore, E.

    1988-01-01

    Three laboratories participated in an interlaboratory study to evaluate the usefulness of the Chinese hamster V79 cell metabolic cooperation assay to predict the tumor-promoting activity of selected chemical. Twenty-three chemicals of different chemical structures (phorbol esters, barbiturates, phenols, artificial sweeteners, alkanes, and peroxides) were chosen for testing based on in vivo promotion activities, as reported in the literature. Assay protocols and materials were standardized, and the chemicals were coded to facilitate unbiased evaluation. A chemical was tested only once in each laboratory, with one of the three laboratories testing only 15 out of 23 chemicals. Dunnett's test was used formore » statistical analysis. Chemicals were scored as positive (at least two concentration levels statistically different than control), equivocal (only one concentration statistically different), or negative. For 15 chemicals tested in all three laboratories, there was complete agreement among the laboratories for nine chemicals. For the 23 chemicals tested in only two laboratories, there was agreement on 16 chemicals. With the exception of the peroxides and alkanes, the metabolic cooperation data were in general agreement with in vivo data. However, an overall evaluation of the V79 cell system for predicting in vivo promotion activity was difficult because of the organ specificity of certain chemicals and/or the limited number of adequately tested nonpromoting chemicals.« less

  14. Validation of the OECD reproduction test guideline with the New Zealand mudsnail Potamopyrgus antipodarum using trenbolone and prochloraz.

    PubMed

    Geiß, Cornelia; Ruppert, Katharina; Askem, Clare; Barroso, Carlos; Faber, Daniel; Ducrot, Virginie; Holbech, Henrik; Hutchinson, Thomas H; Kajankari, Paula; Kinnberg, Karin Lund; Lagadic, Laurent; Matthiessen, Peter; Morris, Steve; Neiman, Maurine; Penttinen, Olli-Pekka; Sanchez-Marin, Paula; Teigeler, Matthias; Weltje, Lennart; Oehlmann, Jörg

    2017-04-01

    The Organisation for Economic Cooperation and Development (OECD) provides several standard test methods for the environmental hazard assessment of chemicals, mainly based on primary producers, arthropods, and fish. In April 2016, two new test guidelines with two mollusc species representing different reproductive strategies were approved by OECD member countries. One test guideline describes a 28-day reproduction test with the parthenogenetic New Zealand mudsnail Potamopyrgus antipodarum. The main endpoint of the test is reproduction, reflected by the embryo number in the brood pouch per female. The development of a new OECD test guideline involves several phases including inter-laboratory validation studies to demonstrate the robustness of the proposed test design and the reproducibility of the test results. Therefore, a ring test of the reproduction test with P. antipodarum was conducted including eight laboratories with the test substances trenbolone and prochloraz and results are presented here. Most laboratories could meet test validity criteria, thus demonstrating the robustness of the proposed test protocol. Trenbolone did not have an effect on the reproduction of the snails at the tested concentration range (nominal: 10-1000 ng/L). For prochloraz, laboratories produced similar EC 10 and NOEC values, showing the inter-laboratory reproducibility of results. The average EC 10 and NOEC values for reproduction (with coefficient of variation) were 26.2 µg/L (61.7%) and 29.7 µg/L (32.9%), respectively. This ring test shows that the mudsnail reproduction test is a well-suited tool for use in the chronic aquatic hazard and risk assessment of chemicals.

  15. Interlaboratory Study of Quality Control Isolates for a Broth Microdilution Method (Modified CLSI M38-A) for Testing Susceptibilities of Dermatophytes to Antifungals▿

    PubMed Central

    Ghannoum, M. A.; Arthington-Skaggs, B.; Chaturvedi, V.; Espinel-Ingroff, A.; Pfaller, M. A.; Rennie, R.; Rinaldi, M. G.; Walsh, T. J.

    2006-01-01

    The Clinical and Laboratory Standards Institute (CLSI; formerly National Committee for Clinical Laboratory Standards, or NCCLS) M38-A standard for the susceptibility testing of filamentous fungi does not specifically address the testing of dermatophytes. In 2003, a multicenter study investigated the reproducibility of the microdilution method developed at the Center for Medical Mycology, Cleveland, Ohio, for testing the susceptibility of dermatophytes. Data from that study supported the introduction of this method for testing dermatophytes in the future version of the CLSI M38-A standard. In order for the method to be accepted by CLSI, appropriate quality control isolates needed to be identified. To that end, an interlaboratory study, involving the original six laboratories plus two additional sites, was conducted to evaluate potential candidates for quality control isolates. These candidate strains included five Trichophyton rubrum strains known to have elevated MICs to terbinafine and five Trichophyton mentagrophytes strains. Antifungal agents tested included ciclopirox, fluconazole, griseofulvin, itraconazole, posaconazole, terbinafine, and voriconazole. Based on the data generated, two quality control isolates, one T. rubrum isolate and one T. mentagrophytes isolate, were identified and submitted to the American Type Culture Collection (ATCC) for inclusion as reference strains. Ranges encompassing 95.2 to 97.9% of all data points for all seven drugs were established. PMID:17050812

  16. Inter-laboratory Comparison of Three Earplug Fit-test Systems

    PubMed Central

    Byrne, David C.; Murphy, William J.; Krieg, Edward F.; Ghent, Robert M.; Michael, Kevin L.; Stefanson, Earl W.; Ahroon, William A.

    2017-01-01

    The National Institute for Occupational Safety and Health (NIOSH) sponsored tests of three earplug fit-test systems (NIOSH HPD Well-Fit™, Michael & Associates FitCheck, and Honeywell Safety Products VeriPRO®). Each system was compared to laboratory-based real-ear attenuation at threshold (REAT) measurements in a sound field according to ANSI/ASA S12.6-2008 at the NIOSH, Honeywell Safety Products, and Michael & Associates testing laboratories. An identical study was conducted independently at the U.S. Army Aeromedical Research Laboratory (USAARL), which provided their data for inclusion in this report. The Howard Leight Airsoft premolded earplug was tested with twenty subjects at each of the four participating laboratories. The occluded fit of the earplug was maintained during testing with a soundfield-based laboratory REAT system as well as all three headphone-based fit-test systems. The Michael & Associates lab had highest average A-weighted attenuations and smallest standard deviations. The NIOSH lab had the lowest average attenuations and the largest standard deviations. Differences in octave-band attenuations between each fit-test system and the American National Standards Institute (ANSI) sound field method were calculated (Attenfit-test - AttenANSI). A-weighted attenuations measured with FitCheck and HPD Well-Fit systems demonstrated approximately ±2 dB agreement with the ANSI sound field method, but A-weighted attenuations measured with the VeriPRO system underestimated the ANSI laboratory attenuations. For each of the fit-test systems, the average A-weighted attenuation across the four laboratories was not significantly greater than the average of the ANSI sound field method. Standard deviations for residual attenuation differences were about ±2 dB for FitCheck and HPD Well-Fit compared to ±4 dB for VeriPRO. Individual labs exhibited a range of agreement from less than a dB to as much as 9.4 dB difference with ANSI and REAT estimates. Factors such as the experience of study participants and test administrators, and the fit-test psychometric tasks are suggested as possible contributors to the observed results. PMID:27786602

  17. A Reference Method for Measuring Emissions of SVOCs in ...

    EPA Pesticide Factsheets

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor

  18. An Interlaboratory Comparison of Dosimetry for a Multi-institutional Radiobiological

    PubMed Central

    Seed, TM; Xiao, S; Manley, N; Nikolich-Zugich, J; Pugh, J; van den Brink, M; Hirabayashi, Y; Yasutomo, K; Iwama, A; Koyasu, S; Shterev, I; Sempowski, G; Macchiarini, F; Nakachi, K; Kunugi, KC; Hammer, CG; DeWerd, LA

    2016-01-01

    Purpose An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Methods Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. Results The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤ 5%. Comparable rates of ‘dosimetric compliance’ were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between ‘measured’ and ‘target’ doses, with errors falling largely between 0–20%. Outliers were most notable for OSL-based tests, while multiple tests by ‘non-compliant’ laboratories using orthovoltage x-rays contributed heavily to the wide variation in dosing errors. Conclusions For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized. PMID:26857121

  19. An interlaboratory comparison of dosimetry for a multi-institutional radiobiological research project: Observations, problems, solutions and lessons learned.

    PubMed

    Seed, Thomas M; Xiao, Shiyun; Manley, Nancy; Nikolich-Zugich, Janko; Pugh, Jason; Van den Brink, Marcel; Hirabayashi, Yoko; Yasutomo, Koji; Iwama, Atsushi; Koyasu, Shigeo; Shterev, Ivo; Sempowski, Gregory; Macchiarini, Francesca; Nakachi, Kei; Kunugi, Keith C; Hammer, Clifford G; Dewerd, Lawrence A

    2016-01-01

    An interlaboratory comparison of radiation dosimetry was conducted to determine the accuracy of doses being used experimentally for animal exposures within a large multi-institutional research project. The background and approach to this effort are described and discussed in terms of basic findings, problems and solutions. Dosimetry tests were carried out utilizing optically stimulated luminescence (OSL) dosimeters embedded midline into mouse carcasses and thermal luminescence dosimeters (TLD) embedded midline into acrylic phantoms. The effort demonstrated that the majority (4/7) of the laboratories was able to deliver sufficiently accurate exposures having maximum dosing errors of ≤5%. Comparable rates of 'dosimetric compliance' were noted between OSL- and TLD-based tests. Data analysis showed a highly linear relationship between 'measured' and 'target' doses, with errors falling largely between 0 and 20%. Outliers were most notable for OSL-based tests, while multiple tests by 'non-compliant' laboratories using orthovoltage X-rays contributed heavily to the wide variation in dosing errors. For the dosimetrically non-compliant laboratories, the relatively high rates of dosing errors were problematic, potentially compromising the quality of ongoing radiobiological research. This dosimetry effort proved to be instructive in establishing rigorous reviews of basic dosimetry protocols ensuring that dosing errors were minimized.

  20. AN INTERLABORATORY STUDY OF PERFLUORINATED ALKYL COMPOUND LEVELS IN HUMAN PLASMA

    EPA Science Inventory

    The present study was designed to investigate intra- and interlaboratory variability in results from six laboratories experienced in the analysis of perfluorinated alkyl compounds in blood matrices and that use stringent procedures to control and assure accuracy and precision. Ea...

  1. More rapid edgewise crush test methods

    Treesearch

    Thomas J. Urbanik; Arthur H. Catlin; Davide R. Friedman; Richard C. Lund

    1993-01-01

    The use of paraffin wax to reinforce the loading edges of corrugated fiberboard edge-crush specimens requires that the specimens be reconditioned after waxing. The traditional practice employing a 24-h reconditioning period is a conservative approach based on the moisture response rate of corrugated containers. An interlaboratory study was conducted to determine the...

  2. Interlaboratory testing of 42-d Hyalella azteca survival, growth and reproduction method with sediment and water-only exposures

    EPA Science Inventory

    Over the past four years, USEPA-Duluth, USGS-Columbia, the Illinois Natural History Survey, and Environment Canada have conducted studies to refine the USEPA/ASTM International methods for conducting 10- to 42-d water or sediment toxicity exposures with Hyalella azteca. In advanc...

  3. Interlaboratory validation of quantitative duplex real-time PCR method for screening analysis of genetically modified maize.

    PubMed

    Takabatake, Reona; Koiwa, Tomohiro; Kasahara, Masaki; Takashima, Kaori; Futo, Satoshi; Minegishi, Yasutaka; Akiyama, Hiroshi; Teshima, Reiko; Oguchi, Taichi; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi

    2011-01-01

    To reduce the cost and time required to routinely perform the genetically modified organism (GMO) test, we developed a duplex quantitative real-time PCR method for a screening analysis simultaneously targeting an event-specific segment for GA21 and Cauliflower Mosaic Virus 35S promoter (P35S) segment [Oguchi et al., J. Food Hyg. Soc. Japan, 50, 117-125 (2009)]. To confirm the validity of the method, an interlaboratory collaborative study was conducted. In the collaborative study, conversion factors (Cfs), which are required to calculate the GMO amount (%), were first determined for two real-time PCR instruments, the ABI PRISM 7900HT and the ABI PRISM 7500. A blind test was then conducted. The limit of quantitation for both GA21 and P35S was estimated to be 0.5% or less. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSD(R)). The determined bias and RSD(R) were each less than 25%. We believe the developed method would be useful for the practical screening analysis of GM maize.

  4. Technical aspects and inter-laboratory variability in native peptide profiling: the CE-MS experience.

    PubMed

    Mischak, Harald; Vlahou, Antonia; Ioannidis, John P A

    2013-04-01

    Mass spectrometry platforms have attracted a lot of interest in the last 2 decades as profiling tools for native peptides and proteins with clinical potential. However, limitations associated with reproducibility and analytical robustness, especially pronounced with the initial SELDI systems, hindered the application of such platforms in biomarker qualification and clinical implementation. The scope of this article is to give a short overview on data available on performance and on analytical robustness of the different platforms for peptide profiling. Using the CE-MS platform as a paradigm, data on analytical performance are described including reproducibility (short-term and intermediate repeatability), stability, interference, quantification capabilities (limits of detection), and inter-laboratory variability. We discuss these issues by using as an example our experience with the development of a 273-peptide marker for chronic kidney disease. Finally, we discuss pros and cons and means for improvement and emphasize the need to test in terms of comparative clinical performance and impact, different platforms that pass reasonably well analytical validation tests. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Interlaboratory study for nickel alloy 625 made by laser powder bed fusion to quantify mechanical property variability.

    PubMed

    Brown, Christopher U; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2016-08-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.

  6. Interlaboratory study for nickel alloy 625 made by laser powder bed fusion to quantify mechanical property variability

    PubMed Central

    Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2017-01-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser-powder-bed-fusion additive manufacturing machines. The tensile specimens were heat treated and tensile tests conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to 4 times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure. PMID:28243032

  7. Interlaboratory Study for Nickel Alloy 625 Made by Laser Powder Bed Fusion to Quantify Mechanical Property Variability

    NASA Astrophysics Data System (ADS)

    Brown, Christopher U.; Jacob, Gregor; Stoudt, Mark; Moylan, Shawn; Slotwinski, John; Donmez, Alkan

    2016-08-01

    Six different organizations participated in this interlaboratory study to quantify the variability in the tensile properties of Inconel 625 specimens manufactured using laser powder bed fusion-additive manufacturing machines. The tensile specimens were heat treated and tensile tests were conducted until failure. The properties measured were yield strength, ultimate tensile strength, elastic modulus, and elongation. Statistical analysis revealed that between-participant variability for yield strength, ultimate tensile strength, and elastic modulus values were significantly higher (up to four times) than typical within-participant variations. Only between-participant and within-participant variability were both similar for elongation. A scanning electron microscope was used to examine one tensile specimen for fractography. The fracture surface does not have many secondary cracks or other features that would reduce the mechanical properties. In fact, the features largely consist of microvoid coalescence and are entirely consistent with ductile failure.

  8. Interlaboratory Validation of the Leaching Environmental Assessment Framework (LEAF) Method 1313 and Method 1316

    EPA Science Inventory

    This document summarizes the results of an interlaboratory study conducted to generate precision estimates for two parallel batch leaching methods which are part of the Leaching Environmental Assessment Framework (LEAF). These methods are: (1) Method 1313: Liquid-Solid Partition...

  9. Interlaboratory comparison for the measurement of particle size and zeta potential of silica nanoparticles in an aqueous suspension

    NASA Astrophysics Data System (ADS)

    Lamberty, Andrée; Franks, Katrin; Braun, Adelina; Kestens, Vikram; Roebben, Gert; Linsinger, Thomas P. J.

    2011-12-01

    The Institute for Reference Materials and Measurements has organised an interlaboratory comparison (ILC) to allow the participating laboratories to demonstrate their proficiency in particle size and zeta potential measurements on monomodal aqueous suspensions of silica nanoparticles in the 10-100 nm size range. The main goal of this ILC was to identify competent collaborators for the production of certified nanoparticle reference materials. 38 laboratories from four different continents participated in the ILC with different methods for particle sizing and determination of zeta potential. Most of the laboratories submitted particle size results obtained with centrifugal liquid sedimentation (CLS), dynamic light scattering (DLS) or electron microscopy (EM), or zeta potential values obtained via electrophoretic light scattering (ELS). The results of the laboratories were evaluated using method-specific z scores, calculated on the basis of consensus values from the ILC. For CLS (13 results) and EM (13 results), all reported values were within the ±2 | z| interval. For DLS, 25 of the 27 results reported were within the ±2 | z| interval, the two other results were within the ±3 | z| interval. The standard deviations of the corresponding laboratory mean values varied between 3.7 and 6.5%, which demonstrates satisfactory interlaboratory comparability of CLS, DLS and EM particle size values. From the received test reports, a large discrepancy was observed in terms of the laboratory's quality assurance systems, which are equally important for the selection of collaborators in reference material certification projects. Only a minority of the participating laboratories is aware of all the items that are mandatory in test reports compliant to ISO/IEC 17025 (ISO General requirements for the competence of testing and calibration laboratories. International Organisation for Standardization, Geneva, 2005b). The absence of measurement uncertainty values in the reports, for example, hindered the calculation of zeta scores.

  10. Interlaboratory study of a method for determining nonvolatile organic carbon in aquifer materials

    USGS Publications Warehouse

    Caughey, M.E.; Barcelona, M.J.; Powell, R.M.; Cahill, R.A.; Gron, C.; Lawrenz, D.; Meschi, P.L.

    1995-01-01

    The organic carbon fraction in aquifer materials exerts a major influence on the subsurface mobilities of organic and organic-associated contaminants. The spatial distribution of total organic carbon (TOC) in aquifer materials must be determined before the transport of hydrophobic organic pollutants in aquifers can be modeled accurately. Previous interlaboratory studies showed that it is difficult to measure TOC concentrations 1%. We have tested a new analytical method designed to improve the accuracy and precision of nonvolatile TOC quantitation in geologic materials that also contain carbonate minerals. Four authentic aquifer materials and one NIST standard reference material were selected as test materials for a blind collaborative study. Nonvolatile TOC in these materials ranged from 0.05 to 1.4%, while TIC ranged from 0.46 to 12.6%. Sample replicates were digested with sulfurous acid, dried at 40??C, and then combusted at 950??C using LECO or UIC instruments. For the three test materials that contained >2% TIC, incomplete acidification resulted in a systematic positive bias of TOC values reported by five of the six laboratories that used the test method. Participants did not have enough time to become proficient with the new method before they analyzed the test materials. A seventh laboratory successfully used an alternative method that analyzed separate liquid and solid fractions of the acidified sample residues. ?? 1995 Springer-Verlag.

  11. THE DEVELOPMENT AND INTER-LABORATORY VERIFICATION OF LC-MS LIBRARIES FOR ORGANIC CHEMICALS OF ENVIRONMENTAL CONCERN

    EPA Science Inventory

    The development, verification, and comparison study between LC-MS libraries for two manufacturers’ instruments and a verified protocol are discussed. The LC-MS library protocol was verified through an inter-laboratory study that involved Federal, State, and private laboratories. ...

  12. Particle size distributions by transmission electron microscopy: an interlaboratory comparison case study

    PubMed Central

    Rice, Stephen B; Chan, Christopher; Brown, Scott C; Eschbach, Peter; Han, Li; Ensor, David S; Stefaniak, Aleksandr B; Bonevich, John; Vladár, András E; Hight Walker, Angela R; Zheng, Jiwen; Starnes, Catherine; Stromberg, Arnold; Ye, Jia; Grulke, Eric A

    2015-01-01

    This paper reports an interlaboratory comparison that evaluated a protocol for measuring and analysing the particle size distribution of discrete, metallic, spheroidal nanoparticles using transmission electron microscopy (TEM). The study was focused on automated image capture and automated particle analysis. NIST RM8012 gold nanoparticles (30 nm nominal diameter) were measured for area-equivalent diameter distributions by eight laboratories. Statistical analysis was used to (1) assess the data quality without using size distribution reference models, (2) determine reference model parameters for different size distribution reference models and non-linear regression fitting methods and (3) assess the measurement uncertainty of a size distribution parameter by using its coefficient of variation. The interlaboratory area-equivalent diameter mean, 27.6 nm ± 2.4 nm (computed based on a normal distribution), was quite similar to the area-equivalent diameter, 27.6 nm, assigned to NIST RM8012. The lognormal reference model was the preferred choice for these particle size distributions as, for all laboratories, its parameters had lower relative standard errors (RSEs) than the other size distribution reference models tested (normal, Weibull and Rosin–Rammler–Bennett). The RSEs for the fitted standard deviations were two orders of magnitude higher than those for the fitted means, suggesting that most of the parameter estimate errors were associated with estimating the breadth of the distributions. The coefficients of variation for the interlaboratory statistics also confirmed the lognormal reference model as the preferred choice. From quasi-linear plots, the typical range for good fits between the model and cumulative number-based distributions was 1.9 fitted standard deviations less than the mean to 2.3 fitted standard deviations above the mean. Automated image capture, automated particle analysis and statistical evaluation of the data and fitting coefficients provide a framework for assessing nanoparticle size distributions using TEM for image acquisition. PMID:26361398

  13. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse.

    PubMed

    Martínez-Granados, Luis; Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost-perfect inter-laboratory agreement among conventional morphological assessment (CMA), EmbryoScope™ and Primo Vision™, except for false divisions, vacuoles and asymmetry (users of all methods) and multinucleation (users of Primo Vision™), where the degree of agreement was lower. The inter-laboratory agreement on embryo classification according to the ASEBIR criteria was moderate-substantial (Gwet 0.41-0.80) for the laboratories using CMA and EmbryoScope™, and fair-moderate (Gwet 0.21-0.60) for those using Primo Vision™. The inter-laboratory agreement for clinical decision was moderate (Gwet 0.41-0.60) on day 5 for CMA users and almost perfect (Gwet 0.81-1) for time-lapse users. In conclusion, time-lapse technology does not improve inter-laboratory agreement on embryo classification or the analysis of each morphological variable. Moreover, depending on the time-lapse platform used, inter-laboratory agreement may be lower than that obtained by CMA. However, inter-laboratory agreement on clinical decisions is improved with the use of time lapse, regardless of the platform used.

  14. Inter-laboratory agreement on embryo classification and clinical decision: Conventional morphological assessment vs. time lapse

    PubMed Central

    Serrano, María; González-Utor, Antonio; Ortíz, Nereyda; Badajoz, Vicente; Olaya, Enrique; Prados, Nicolás; Boada, Montse; Castilla, Jose A.

    2017-01-01

    The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost-perfect inter-laboratory agreement among conventional morphological assessment (CMA), EmbryoScope™ and Primo Vision™, except for false divisions, vacuoles and asymmetry (users of all methods) and multinucleation (users of Primo Vision™), where the degree of agreement was lower. The inter-laboratory agreement on embryo classification according to the ASEBIR criteria was moderate-substantial (Gwet 0.41–0.80) for the laboratories using CMA and EmbryoScope™, and fair-moderate (Gwet 0.21–0.60) for those using Primo Vision™. The inter-laboratory agreement for clinical decision was moderate (Gwet 0.41–0.60) on day 5 for CMA users and almost perfect (Gwet 0.81–1) for time-lapse users. In conclusion, time-lapse technology does not improve inter-laboratory agreement on embryo classification or the analysis of each morphological variable. Moreover, depending on the time-lapse platform used, inter-laboratory agreement may be lower than that obtained by CMA. However, inter-laboratory agreement on clinical decisions is improved with the use of time lapse, regardless of the platform used. PMID:28841654

  15. Pilot Inter-Laboratory Studies for Evaluating Weathering-Induced Release of Carbon Nanotubes from Solid Matrices

    EPA Science Inventory

    Nanomaterials are increasingly being used in polymer composites to enhance the properties of these materials. Here we present results of a pilot inter-laboratory study to simulate the effects of weathering on the potential release of multiwalled carbon nanotubes (MWCNT) from thei...

  16. Interlaboratory Validation of the Leaching Environmental Assessment Framework (LEAF) Method 1314 and Method 1315

    EPA Science Inventory

    This report summarizes the results of an interlaboratory study conducted to generate precision estimates for two leaching methods under review by the U.S. EPA’s OSWER for inclusion into the EPA’s SW-846: Method 1314: Liquid-Solid Partitioning as a Function of Liquid...

  17. Making the Case for Objective Performance Metrics in Newborn Screening by Tandem Mass Spectrometry

    ERIC Educational Resources Information Center

    Rinaldo, Piero; Zafari, Saba; Tortorelli, Silvia; Matern, Dietrich

    2006-01-01

    The expansion of newborn screening programs to include multiplex testing by tandem mass spectrometry requires understanding and close monitoring of performance metrics. This is not done consistently because of lack of defined targets, and interlaboratory comparison is almost nonexistent. Between July 2004 and April 2006 (N = 176,185 cases), the…

  18. Statistical analysis of an inter-laboratory comparison of small-scale safety and thermal testing of RDX

    DOE PAGES

    Brown, Geoffrey W.; Sandstrom, Mary M.; Preston, Daniel N.; ...

    2014-11-17

    In this study, the Integrated Data Collection Analysis (IDCA) program has conducted a proficiency test for small-scale safety and thermal (SSST) testing of homemade explosives (HMEs). Described here are statistical analyses of the results from this test for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Class 5 Type II standard. The material was tested as a well-characterized standard several times during the proficiency test to assess differences among participants and the range of results that may arise for well-behaved explosive materials.

  19. Inter-Laboratory Comparison for Calibration of Relative Humidity Devices Among Accredited Laboratories in Malaysia

    NASA Astrophysics Data System (ADS)

    Hussain, F.; Khairuddin, S.; Othman, H.

    2017-01-01

    An inter-laboratory comparison in relative humidity measurements among accredited laboratories has been coordinated by the National Metrology Institute of Malaysia. It was carried out to determine the performance of the participating laboratories. The objective of the comparison was to acknowledge the participating laboratories competencies and to verify the level of accuracies declared in their scope of accreditation, in accordance with the MS ISO/IEC 17025 accreditation. The measurement parameter involved was relative humidity for the range of 30-90 %rh at a nominal temperature of 50°C. Eight accredited laboratories participated in the inter-laboratory comparison. Two units of artifacts have been circulated among the participants as the transfer standards.

  20. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Toward a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Hacke, Peter L.; Kempe, Michael D.

    2015-06-14

    Reduced optical transmittance of encapsulation resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of installations in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xe, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests. Index Terms -- reliability, durability, thermal activation.« less

  1. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    2015-08-12

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.« less

  2. Degradation in PV Encapsulation Transmittance: An Interlaboratory Study Towards a Climate-Specific Test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, David C.; Annigoni, Eleonora; Ballion, Amal

    2015-06-14

    Reduced optical transmittance of encapsulants resulting from ultraviolet (UV) degradation has frequently been identified as a cause of decreased PV module performance through the life of service in the field. The present module safety and qualification standards, however, apply short UV doses only capable of examining design robustness or 'infant mortality' failures. Essential information that might be used to screen encapsulation through product lifetime remains unknown. For example, the relative efficacy of xenon-arc and UVA-340 fluorescent sources or the typical range of activation energy for degradation is not quantified. We have conducted an interlaboratory experiment to provide the understanding thatmore » will be used towards developing a climate- and configuration-specific (UV) weathering test. Five representative, known formulations of EVA were studied in addition to one TPU material. Replicate laminated silica/polymer/silica specimens are being examined at 14 institutions using a variety of indoor chambers (including Xenon, UVA-340, and metal-halide light sources) or field aging. The solar-weighted transmittance, yellowness index, and the UV cut-off wavelength, determined from the measured hemispherical transmittance, are examined to provide understanding and guidance for the UV light source (lamp type) and temperature used in accelerated UV aging tests.« less

  3. INTERLABORATORY COMPARISON OF MASS SPECTROMETRIC METHODS FOR LEAD ISOTOPES AND TRACE ELEMENTS IN NIST SRM 1400 BONE ASH

    EPA Science Inventory

    The results of an interlaboratory comparison are reported for he lead isotope composition and for trace element concentrations in NIST SRM 1400 Bone Ash obtained using quadrupole and magnetic-sector inductively coupled plasma mass spectrometry (ICP-MS) and (for the Pb isotopes on...

  4. INTERLABORATORY STUDY OF A THERMOSPRAY-LIQUID CHROMATOGRAPHIC/MASS SPECTROMETRIC METHOD FOR SELECTED N-METHYL CARBAMATES, N-METHYL CARBAMOYLOXIMES, AND SUBSTITUTED UREA PESTICIDES

    EPA Science Inventory

    A thermospray-liquid chromatographic/mass spectrometric (TS-LC/MS) method was evaluated in an interlaboratory study for determining 3 N-methyl carbamates (bendiocarb, carbaryl, and carbofuran), 3-N-methyl carbamoyloximes (aldicarb, methomyl, and oxamyl), 2 substituted urea pestic...

  5. Precision of the upgraded cottonscan instrument for measuring the average fiber linear density (fineness) of cotton lint samples

    USDA-ARS?s Scientific Manuscript database

    An inter-laboratory trial was conducted to validate the operation of the CottonscanTM technology as useful technique for determining the average fiber linear density of cotton. A significant inter-laboratory trial was completed and confirmed that the technology is quite acceptable. For fibers fin...

  6. Sample Integrity Evaluation and EPA Method 325b Interlaboratory Comparison for Select Volatile Organic Compounds Collected Diffusively on Carbopack X Sorbent Tubes

    EPA Science Inventory

    Sample integrity evaluations and inter-laboratory comparisons were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A/B for monitoring benzene and additional selected volatile organic compounds (VOCs) usingpassive-diffusive Carbopack X tube sample...

  7. ORGANIC CHARACTERIZATION OF AIRBORNE PARTICLES: INTERLABORATORY COMPARISON STUDIES AND THE DEVELOPMENT OF STANDARDS AND REFERENCE MATERIALS

    EPA Science Inventory

    Investigators characterizing and quantifying the organic compounds in particulate matter (PM) have completed the second interlaboratory comparison study. The first study used a subset of SRM1649a sieved to <63um(API) as an unknown sample, an extract of API, and SRM1649a for u...

  8. Interlaboratory comparison of real-time pcr protocols for quantification of general fecal indicator bacteria

    USGS Publications Warehouse

    Shanks, O.C.; Sivaganesan, M.; Peed, L.; Kelty, C.A.; Blackwood, A.D.; Greene, M.R.; Noble, R.T.; Bushon, R.N.; Stelzer, E.A.; Kinzelman, J.; Anan'Eva, T.; Sinigalliano, C.; Wanless, D.; Griffith, J.; Cao, Y.; Weisberg, S.; Harwood, V.J.; Staley, C.; Oshima, K.H.; Varma, M.; Haugland, R.A.

    2012-01-01

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol. ?? 2011 American Chemical Society.

  9. Determination of total dietary fiber in selected foods containing resistant maltodextrin by a simplified enzymatic-gravimetric method and liquid chromatography: interlaboratory study in China.

    PubMed

    Fu, Boqiang; Wang, Jing; Roturier, Jean Michel; Tang, Zhiyu; Li, Huan; Wei, Guangyan

    2008-01-01

    An interlaboratory study was conducted in China to validate the modified AOAC Official Method 2001.03 for the determination of total dietary fiber (TDF) in foods containing resistant maltodextrin (RMD), which will be adopted as the National Standard Method of China. The kind of buffer solution, the volume of filtrate evaporation, the volume of eluent for desalting and residual solution after evaporation, etc. were modified, which had been proved to have acceptable accuracy and precision in the routine assay. TDF contents in 3 representative foods and 2 kinds of RMD ingredient (i.e., NUTRIOSE 06 and NUTRIOSE 10) were measured using the modified method in 6 eligible laboratories representing commercial, industrial, and governmental laboratories in China. The results of the interlaboratory study indicated that the intralaboratory repeatability, interlaboratory reproducibility, and precision of the modified method are adequate for reliable analysis of TDF in food containing RMD, as well as resistant dextrin. Compared to AOAC Official Method 2001.03, the modified method is time- and cost-saving.

  10. PSU/WES Interlaboratory Comparative Methodology Study of an Experimental Cementitious Repository Seal Material. Report 2. Final Results.

    DTIC Science & Technology

    1982-03-01

    meter 25 11.0 Microstructure by SEM 11.1 Introduction In order to correlate observed physical and mechanical properties in cured grout samples, a...studied at the two laboratories has proper physical properties , phase composi- tions, and microstructures for the materials used and ages covered...Scanning Electron Microscope Resolution Test Specimen ( Al -W) D. B. Ballard Research Material 100 SEM Resolution Test Specimen (AI-W)., is an alloy of

  11. Interlaboratory comparability, bias, and precision for four laboratories measuring constituents in precipitation, November 1982-August 1983

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Malo, B.A.

    1985-01-01

    Four laboratories were evaluated in their analysis of identical natural and simulated precipitation water samples. Interlaboratory comparability was evaluated using analysis of variance coupled with Duncan 's multiple range test, and linear-regression models describing the relations between individual laboratory analytical results for natural precipitation samples. Results of the statistical analyses indicate that certain pairs of laboratories produce different results when analyzing identical samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple range test on data produced by the laboratories from the analysis of identical simulated precipitation samples. Bias for a given analyte produced by a single laboratory has been indicated when the laboratory mean for that analyte is shown to be significantly different from the mean for the most-probable analyte concentrations in the simulated precipitation samples. Ion-chromatographic methods for the determination of chloride, nitrate, and sulfate have been compared with the colorimetric methods that were also in use during the study period. Comparisons were made using analysis of variance coupled with Duncan 's multiple range test for means produced by the two methods. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Analyte estimated precisions have been compared using F-tests and differences in analyte precisions for laboratory pairs have been reported. (USGS)

  12. An Ibero-American inter-laboratory trial to evaluate serological tests for the detection of anti-Neospora caninum antibodies in cattle.

    PubMed

    Campero, Lucía M; Moreno-Gonzalo, Javier; Venturini, María C; Moré, Gastón; Dellarupe, Andrea; Rambeaud, Magdalena; Echaide, Ignacio E; Valentini, Beatriz; Campero, Carlos M; Moore, Dadín P; Cano, Dora B; Fort, Marcelo; Mota, Rinaldo A; Serrano-Martínez, Marcos E; Cruz-Vázquez, Carlos; Ortega-Mora, Luis M; Álvarez-García, Gema

    2018-01-01

    We carried out an inter-laboratory trial to compare the serological tests commonly used for the detection of specific Neospora caninum antibodies in cattle in Ibero-American countries. A total of eight laboratories participated from the following countries: Argentina (n = 4), Brazil (n = 1), Peru (n = 1), Mexico (n = 1), and Spain (n = 1). A blind panel of well-characterized cattle sera (n = 143) and sera representative of the target population (n = 351) was tested by seven in-house indirect fluorescent antibody tests (IFATs 1-7) and three enzyme-linked immunosorbent assays (ELISAs 1-3; two in-house and one commercial). Diagnostic performance of the serological tests was calculated and compared according to the following criteria: (1) the "Pre-test information," which uses previous epidemiological and serological data; (2) the "Majority of tests," which classifies a serum as positive or negative according to the results obtained by most tests evaluated. Unexpectedly, six tests showed either sensitivity (Se) or specificity (Sp) values lower than 90%. In contrast, the best tests in terms of Se, Sp, and area under the ROC curve (AUC) values were IFAT 1 and optimized ELISA 1 and ELISA 2. We evaluated a high number of IFATs, which are the most widely used tests in Ibero-America. The significant discordances observed among the tests regardless of the criteria employed hinder control programs and urge the use of a common test or with similar performances to either the optimized IFAT 1 and ELISAs 1 and 2.

  13. White Sands Missile Range Overview & Introduction: Test Capabilities Briefing

    DTIC Science & Technology

    2011-11-07

    PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Army Test and Evaluation Command (ATEC),White Sands Missile Range,White Sands Missile Range,NM,88002...5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR...solar radiation, icing, salt fog, etc. • Instrumented for system performance / diagnostics  Climatics testing capabilities • Fixed and mobile test

  14. The Development of a Novel, Validated, Rapid and Simple Method for the Detection of Sarcocystis fayeri in Horse Meat in the Sanitary Control Setting.

    PubMed

    Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro

    2016-01-01

    Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.

  15. Role and Evaluation of Interlaboratory Comparison Results in Laboratory Accreditation

    NASA Astrophysics Data System (ADS)

    Bode, P.

    2008-08-01

    Participation in interlaboratory comparisons provides laboratories an opportunity for independent assessment of their analytical performance, both in absolute way and in comparison with those by other techniques. However, such comparisons are hindered by differences in the way laboratories participate, e.g. at best measurement capability or under routine conditions. Neutron activation analysis laboratories, determining total mass fractions, often see themselves classified as `outliers' since the majority of other participants employ techniques with incomplete digestion methods. These considerations are discussed in relation to the way results from interlaboratory comparisons are evaluated by accreditation bodies following the requirements of Clause 5.9.1 of the ISO/IEC 17025:2005. The discussion and conclusions come largely forth from experiences in the author's own laboratory.

  16. [Statistical approach to evaluate the occurrence of out-of acceptable ranges and accuracy for antimicrobial susceptibility tests in inter-laboratory quality control program].

    PubMed

    Ueno, Tamio; Matuda, Junichi; Yamane, Nobuhisa

    2013-03-01

    To evaluate the occurrence of out-of acceptable ranges and accuracy of antimicrobial susceptibility tests, we applied a new statistical tool to the Inter-Laboratory Quality Control Program established by the Kyushu Quality Control Research Group. First, we defined acceptable ranges of minimum inhibitory concentration (MIC) for broth microdilution tests and inhibitory zone diameter for disk diffusion tests on the basis of Clinical and Laboratory Standards Institute (CLSI) M100-S21. In the analysis, more than two out-of acceptable range results in the 20 tests were considered as not allowable according to the CLSI document. Of the 90 participating laboratories, 46 (51%) experienced one or more occurrences of out-of acceptable range results. Then, a binomial test was applied to each participating laboratory. The results indicated that the occurrences of out-of acceptable range results in the 11 laboratories were significantly higher when compared to the CLSI recommendation (allowable rate < or = 0.05). The standard deviation indices(SDI) were calculated by using reported results, mean and standard deviation values for the respective antimicrobial agents tested. In the evaluation of accuracy, mean value from each laboratory was statistically compared with zero using a Student's t-test. The results revealed that 5 of the 11 above laboratories reported erroneous test results that systematically drifted to the side of resistance. In conclusion, our statistical approach has enabled us to detect significantly higher occurrences and source of interpretive errors in antimicrobial susceptibility tests; therefore, this approach can provide us with additional information that can improve the accuracy of the test results in clinical microbiology laboratories.

  17. Forensic interlaboratory evaluation of the ForFLUID kit for vaginal fluids identification.

    PubMed

    Giampaoli, Saverio; Alessandrini, Federica; Berti, Andrea; Ripani, Luigi; Choi, Ajin; Crab, Roselien; De Vittori, Elisabetta; Egyed, Balazs; Haas, Cordula; Lee, Hwan Young; Korabecná, Marie; Noel, Fabrice; Podini, Daniele; Tagliabracci, Adriano; Valentini, Alessio; Romano Spica, Vincenzo

    2014-01-01

    Identification of vaginal fluids is an important step in the process of sexual assaults confirmation. Advances in both microbiology and molecular biology defined technical approaches allowing the discrimination of body fluids. These protocols are based on the identification of specific bacterial communities by microfloraDNA (mfDNA) amplification. A multiplex real time-PCR assay (ForFLUID kit) has been developed for identifying biological fluids and for discrimination among vaginal, oral and fecal samples. In order to test its efficacy and reliability of the assay in the identification of vaginal fluids, an interlaboratory evaluation has been performed on homogeneous vaginal swabs. All the involved laboratories were able to correctly recognize all the vaginal swabs, and no false positives were identified when the assay was applied on non-vaginal samples. The assay represents an useful molecular tool that can be easily adopted by forensic geneticists involved in vaginal fluid identification. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    EPA Science Inventory

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practica...

  19. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    EPA Science Inventory

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical...

  20. Empirical insights and considerations for the OBT inter-laboratory comparison of environmental samples.

    PubMed

    Kim, Sang-Bog; Roche, Jennifer

    2013-08-01

    Organically bound tritium (OBT) is an important tritium species that can be measured in most environmental samples, but has only recently been recognized as a species of tritium in these samples. Currently, OBT is not routinely measured by environmental monitoring laboratories around the world. There are no certified reference materials (CRMs) for environmental samples. Thus, quality assurance (QA), or verification of the accuracy of the OBT measurement, is not possible. Alternatively, quality control (QC), or verification of the precision of the OBT measurement, can be achieved. In the past, there have been differences in OBT analysis results between environmental laboratories. A possible reason for the discrepancies may be differences in analytical methods. Therefore, inter-laboratory OBT comparisons among the environmental laboratories are important and would provide a good opportunity for adopting a reference OBT analytical procedure. Due to the analytical issues, only limited information is available on OBT measurement. Previously conducted OBT inter-laboratory practices are reviewed and the findings are described. Based on our experiences, a few considerations were suggested for the international OBT inter-laboratory comparison exercise to be completed in the near future. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  1. Use of the Cultex® Radial Flow System as an in vitro exposure method to assess acute pulmonary toxicity of fine dusts and nanoparticles with special focus on the intra- and inter-laboratory reproducibility.

    PubMed

    Steinritz, Dirk; Möhle, Niklas; Pohl, Christine; Papritz, Mirko; Stenger, Bernhard; Schmidt, Annette; Kirkpatrick, Charles James; Thiermann, Horst; Vogel, Richard; Hoffmann, Sebastian; Aufderheide, Michaela

    2013-12-05

    Exposure of the respiratory tract to airborne particles (including metal-dusts and nano-particles) is considered as a serious health hazard. For a wide range of substances basic knowledge about the toxic properties and the underlying pathomechanisms is lacking or even completely missing. Legislation demands the toxicological characterization of all chemicals placed on the market until 2018 (REACH). As toxicological in vivo data are rare with regard to acute lung toxicity or exhibit distinct limitations (e.g. inter-species differences) and legislation claims the reduction of animal experiments in general ("3R" principle), profound in vitro models have to be established and characterized to meet these requirements. In this paper we characterize a recently introduced advanced in vitro exposure system (Cultex® RFS) showing a great similarity to the physiological in vivo exposure situation for the assessment of acute pulmonary toxicity of airborne materials. Using the Cultex® RFS, human lung epithelial cells (A549 cells) were exposed to different concentrations of airborne metal dusts (nano- and microscale particles) at the air-liquid-interface (ALI). Cell viability (WST-1 assay) as a parameter of toxicity was assessed 24h after exposure with special focus on the intra- and inter-laboratory (three independent laboratories) reproducibility. Our results show the general applicability of the Cultex® RFS with regard to the requirements of the ECVAM (European Centre for the Validation of Alternative Methods) principles on test validity underlining its robustness and stability. Intra- and inter-laboratory reproducibility can be considered as sufficient if predefined quality criteria are respected. Special attention must be paid to the pure air controls that turned out to be a critical parameter for a rational interpretation of the results. Our results are encouraging and future work is planned to improve the inter-laboratory reproducibility, to consolidate the results so far and to develop a valid prediction model. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Interlaboratory validation of the modified murine local lymph node assay based on adenosine triphosphate measurement.

    PubMed

    Omori, Takashi; Idehara, Kenji; Kojima, Hajime; Sozu, Takashi; Arima, Kazunori; Goto, Hirohiko; Hanada, Tomohiko; Ikarashi, Yoshiaki; Inoda, Taketo; Kanazawa, Yukiko; Kosaka, Tadashi; Maki, Eiji; Morimoto, Takashi; Shinoda, Shinsuke; Shinoda, Naoki; Takeyoshi, Masahiro; Tanaka, Masashi; Uratani, Mamoru; Usami, Masahito; Yamanaka, Atsushi; Yoneda, Tomofumi; Yoshimura, Isao; Yuasa, Atsuko

    2008-01-01

    The murine local lymph node assay (LLNA) is a well-established alternative to the guinea pig maximization test (GPMT) or Buehler test (BT) for the assessment of the skin sensitizing ability of drugs and chemicals. Daicel Chemical Industries Ltd. has developed a modified LLNA based on the adenosine triphosphate (ATP) content (LLNA-DA). We conducted 2 interlaboratory validation studies to evaluate the reliability and relevance of LLNA-DA. The experiment involved 17 laboratories, wherein 14 chemicals were examined under blinded conditions. In the first study, 3 chemicals were examined in 10 laboratories and the remaining 9 were examined in 3 laboratories. In the second study, 1 chemical was examined in 7 laboratories and the remaining 4 chemicals were examined in 4 laboratories. The data were expressed as the ATP content for each chemical-treated group, and the stimulation index (SI) for each chemical-treated group was determined as the increase in the ATP content relative to the concurrent vehicle control group. An SI of 3 was set as the cut-off value for exhibiting skin sensitization activity. The results of the first study obtained in the experiments conducted for the 3 chemicals that were examined in all the 10 laboratories and for 5 of the remaining 9 chemicals were sufficiently consistent with small variations in their SI values. The sensitivity, specificity, and accuracy of LLNA-DA against those of GPMT/BT were 7/8 (87.5%), 3/3 (100%), and 10/11 (90.9%), respectively. In the second study, all the 5 chemicals studied demonstrated acceptably small interlaboratory variations. In the first study, a large variation was observed for 2 chemicals; in the second study, this variation was small. It was attributed to the application of dimethylsulfoxide as the solvent for the metallic salts. In conclusion, these 2 studies provide good evidence for the reliability of the LLNA-DA.

  3. Interlaboratory comparison of immunohistochemical testing for HER2: results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey.

    PubMed

    Fitzgibbons, Patrick L; Murphy, Douglas A; Dorfman, David M; Roche, Patrick C; Tubbs, Raymond R

    2006-10-01

    Correct assessment of human epidermal growth factor receptor 2 (HER2) status is essential in managing patients with invasive breast carcinoma, but few data are available on the accuracy of laboratories performing HER2 testing by immunohistochemistry (IHC). To review the results of the 2004 and 2005 College of American Pathologists HER2 Immunohistochemistry Tissue Microarray Survey. The HER2 survey is designed for laboratories performing immunohistochemical staining and interpretation for HER2. The survey uses tissue microarrays, each consisting of ten 3-mm tissue cores obtained from different invasive breast carcinomas. All cases are also analyzed by fluorescence in situ hybridization. Participants receive 8 tissue microarrays (80 cases) with instructions to perform immunostaining for HER2 using the laboratory's standard procedures. The laboratory interprets the stained slides and returns results to the College of American Pathologists for analysis. In 2004 and 2005, a core was considered "graded" when at least 90% of laboratories agreed on the result--negative (0, 1+) versus positive (2+, 3+). This interlaboratory comparison survey included 102 laboratories in 2004 and 141 laboratories in 2005. Of the 160 cases in both surveys, 111 (69%) achieved 90% consensus (graded). All 43 graded cores scored as IHC-positive were fluorescence in situ hybridization-positive, whereas all but 3 of the 68 IHC-negative graded cores were fluorescence in situ hybridization-negative. Ninety-seven (95%) of 102 laboratories in 2004 and 129 (91%) of 141 laboratories in 2005 correctly scored at least 90% of the graded cores. Performance among laboratories performing HER2 IHC in this tissue microarray-based survey was excellent. Cores found to be IHC-positive or IHC-negative by participant consensus can be used as validated benchmarks for interlaboratory comparison, allowing laboratories to assess their performance and determine if improvements are needed.

  4. Current activities in standardization of high-temperature, low-cycle-fatigue testing techniques in the United States

    NASA Technical Reports Server (NTRS)

    Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.

    1990-01-01

    The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.

  5. Reliability on intra-laboratory and inter-laboratory data of hair mineral analysis comparing with blood analysis.

    PubMed

    Namkoong, Sun; Hong, Seung Phil; Kim, Myung Hwa; Park, Byung Cheol

    2013-02-01

    Nowadays, although its clinical value remains controversial institutions utilize hair mineral analysis. Arguments about the reliability of hair mineral analysis persist, and there have been evaluations of commercial laboratories performing hair mineral analysis. The objective of this study was to assess the reliability of intra-laboratory and inter-laboratory data at three commercial laboratories conducting hair mineral analysis, compared to serum mineral analysis. Two divided hair samples taken from near the scalp were submitted for analysis at the same time, to all laboratories, from one healthy volunteer. Each laboratory sent a report consisting of quantitative results and their interpretation of health implications. Differences among intra-laboratory and interlaboratory data were analyzed using SPSS version 12.0 (SPSS Inc., USA). All the laboratories used identical methods for quantitative analysis, and they generated consistent numerical results according to Friedman analysis of variance. However, the normal reference ranges of each laboratory varied. As such, each laboratory interpreted the patient's health differently. On intra-laboratory data, Wilcoxon analysis suggested they generated relatively coherent data, but laboratory B could not in one element, so its reliability was doubtful. In comparison with the blood test, laboratory C generated identical results, but not laboratory A and B. Hair mineral analysis has its limitations, considering the reliability of inter and intra laboratory analysis comparing with blood analysis. As such, clinicians should be cautious when applying hair mineral analysis as an ancillary tool. Each laboratory included in this study requires continuous refinement from now on for inducing standardized normal reference levels.

  6. Interlaboratory study for the validation of an ecotoxicological procedure to monitor the quality of septic sludge received at a wastewater treatment plant.

    PubMed

    Robidoux, P Y; Choucri, A; Bastien, C; Sunahara, G I; López-Gastey, J

    2001-01-01

    Septic tank sludge is regularly hauled to the Montreal Urban Community (MUC) wastewater treatment plant. It is then discharged and mixed with the wastewater inflow before entering the primary chemical treatment process. An ecotoxicological procedure integrating chemical and toxicological analyses has been recently developed and applied to screen for the illicit discharge of toxic substances in septic sludge. The toxicity tests used were the Microtox, the bacterial-respiration, and the lettuce (Lactuca sativa) root elongation tests. In order to validate the applicability of the proposed procedure, a two-year interlaboratory study was carried out. In general, the results obtained by two independent laboratories (MUC and the Centre d'expertise en analyse environnementale du Quebec) were comparable and reproducible. Some differences were found using the Microtox test. Organic (e.g., phenol and formaldehyde) and inorganic (e.g., nickel and cyanide) spiked septic sludge were detected with good reliability and high efficiency. The relative efficiency to detect spiked substances was > 70% and confirms the results of previous studies. In addition, the respiration test was the most efficient toxicological tool to detect spiked substances, whereas the Microtox was the least efficient (< 15%). Efficiencies to detect spiked contaminants were also similar for both laboratories. These results support previous data presented earlier and contribute to the validation of the ecotoxicological procedure used by the MUC to screen toxicity in septic sludge.

  7. Collaborative investigation of broth microdilution and semisolid agar dilution for in vitro susceptibility testing of Candida albicans.

    PubMed Central

    Shawar, R; Paetznick, V; Witte, Z; Ensign, L G; Anaissie, E; LaRocco, M

    1992-01-01

    A study was performed in two laboratories to evaluate the effect of growth medium and test methodology on inter- and intralaboratory variations in the MICs of amphotericin B (AMB), flucytosine (5FC), fluconazole (FLU), itraconazole (ITRA), and the triazole Sch 39304 (SCH) against 14 isolates of Candida albicans. Testing was performed by broth microdilution and semisolid agar dilution with the following media, buffered to pH 7.0 with morpholinepropanesulfonic acid (MOPS): buffered yeast nitrogen base (BYNB), Eagle's minimal essential medium (EMEM), RPMI 1640 medium (RPMI), and synthetic amino acid medium for fungi (SAAMF). Inocula were standardized spectrophotometrically, and endpoints were defined by the complete absence of growth for AMB and by no more than 25% of the growth in the drug-free control for all other agents. Comparative analyses of median MICs, as determined by each test method, were made for all drug-medium combinations. Both methods yielded similar (+/- 1 twofold dilution) median MICs for AMB in EMEM and RPMI, 5FC in all media, and FLU in EMEM, RPMI, and SAAMF. In contrast, substantial between-method variations in median MICs were seen for AMB in BYNB and SAAMF, FLU In BYNB, and ITRA and SCH in all media. Interlaboratory concordance of median MICs was good for AMB, 5FC, and FLU but poor for ITRA and SCH in all media. Endpoint determinations were analyzed by use of kappa statistical analyses for evaluating the strength of observer agreement. Moderate to almost perfect interlaboratory agreement occurred with AMB and 5FC in all media and with FLU in EMEM, RPMI, and SAAMF, irrespective of the test method. Slight to almost perfect interlaboratory agreement occurred with ITRA and SCH in EMEM, RPMI, and SAAMF when tested by semisolid agar dilution but not broth microdilution. Kappa values assessing intralaboratory agreement between methods were high for 5FC in all media, for AMB in BYNB, ENEM, and RPMI, and for FLU in EMEM, RPMI, and SAAMF. One laboratory, but not the other, reported substantial to almost perfect agreement between methods for ITRA, and SCH in EMEM, RPMI, and SAAMF. Both laboratories reported poor agreement between methods for the azoles in BYNB. Discrepancies noted in azole-BYNB combinations were largely due to the greater inhibitory effect of these agents in BYNB than in other media. These results indicate that the semisolid agar dilution and broth microdilution methods with EMEM or RPMI yield equivalent and reproducible MICs for AMB, 5FC, and FLU but not ITRA and SCH. PMID:1500502

  8. Collaborative investigation of broth microdilution and semisolid agar dilution for in vitro susceptibility testing of Candida albicans.

    PubMed

    Shawar, R; Paetznick, V; Witte, Z; Ensign, L G; Anaissie, E; LaRocco, M

    1992-08-01

    A study was performed in two laboratories to evaluate the effect of growth medium and test methodology on inter- and intralaboratory variations in the MICs of amphotericin B (AMB), flucytosine (5FC), fluconazole (FLU), itraconazole (ITRA), and the triazole Sch 39304 (SCH) against 14 isolates of Candida albicans. Testing was performed by broth microdilution and semisolid agar dilution with the following media, buffered to pH 7.0 with morpholinepropanesulfonic acid (MOPS): buffered yeast nitrogen base (BYNB), Eagle's minimal essential medium (EMEM), RPMI 1640 medium (RPMI), and synthetic amino acid medium for fungi (SAAMF). Inocula were standardized spectrophotometrically, and endpoints were defined by the complete absence of growth for AMB and by no more than 25% of the growth in the drug-free control for all other agents. Comparative analyses of median MICs, as determined by each test method, were made for all drug-medium combinations. Both methods yielded similar (+/- 1 twofold dilution) median MICs for AMB in EMEM and RPMI, 5FC in all media, and FLU in EMEM, RPMI, and SAAMF. In contrast, substantial between-method variations in median MICs were seen for AMB in BYNB and SAAMF, FLU In BYNB, and ITRA and SCH in all media. Interlaboratory concordance of median MICs was good for AMB, 5FC, and FLU but poor for ITRA and SCH in all media. Endpoint determinations were analyzed by use of kappa statistical analyses for evaluating the strength of observer agreement. Moderate to almost perfect interlaboratory agreement occurred with AMB and 5FC in all media and with FLU in EMEM, RPMI, and SAAMF, irrespective of the test method. Slight to almost perfect interlaboratory agreement occurred with ITRA and SCH in EMEM, RPMI, and SAAMF when tested by semisolid agar dilution but not broth microdilution. Kappa values assessing intralaboratory agreement between methods were high for 5FC in all media, for AMB in BYNB, ENEM, and RPMI, and for FLU in EMEM, RPMI, and SAAMF. One laboratory, but not the other, reported substantial to almost perfect agreement between methods for ITRA, and SCH in EMEM, RPMI, and SAAMF. Both laboratories reported poor agreement between methods for the azoles in BYNB. Discrepancies noted in azole-BYNB combinations were largely due to the greater inhibitory effect of these agents in BYNB than in other media. These results indicate that the semisolid agar dilution and broth microdilution methods with EMEM or RPMI yield equivalent and reproducible MICs for AMB, 5FC, and FLU but not ITRA and SCH.

  9. Results of interlaboratory comparison of fission track ages for 1992 fission track workshop

    USGS Publications Warehouse

    Miller, D.S.; Crowley, K.D.; Dokka, R.K.; Galbraith, R.F.; Kowallis, B.J.; Naeser, C.W.

    1993-01-01

    Two apatites and one sphene were made available to the fission track research community for analysis prior to the 1992 Fission Track Workshop held in Philadelphia, U.S.A., 13-17 July. Eighteen laboratories throughout the world received aliquots of apatite and sphene. To date, analyses by 33 different scientists have been representing 15 different laboratories. With respect to the previous two interlaboratory comparisons, there is a noticeable improvement in the accuracy of the age results (Naeser and Cebula, 1978; Naeser et al., 1981; Miller et al., 1985;Miller et al.1990). Ninety-four percent of the analysis used the external detector method (EDM) combined with the zeta technique while the remaining individuals used the population method (POP). Track length measurements (requested for the first time in the interlaboratory comparison studies) were in relatively good agreement. ?? 1993.

  10. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  11. Inter-laboratory evaluation of the performance parameters of a Lateral Flow Test device for the detection of Bluetongue virus-specific antibodies.

    PubMed

    Hanon, Jean-Baptiste; Vandenberge, Valerie; Deruelle, Matthias; De Leeuw, Ilse; De Clercq, Kris; Van Borm, Steven; Koenen, Frank; Liu, Lihong; Hoffmann, Bernd; Batten, Carrie Anne; Zientara, Stéphan; Breard, Emmanuel; Van der Stede, Yves

    2016-02-01

    Bluetongue (BT) is a viral vector-borne disease affecting domestic and wild ruminants worldwide. In this study, a commercial rapid immuno-chromatographic method or Lateral Flow Test (LFT) device, for the detection of BT virus-specific antibodies in animal serum, was evaluated in an international inter-laboratory proficiency test. The evaluation was done with sera samples of variable background (ruminant species, serotype, field samples, experimental infections, vaccinated animals). The diagnostic sensitivity was 100% (95% C.I. [90.5-100]) and the diagnostic specificity was 95.2% (95% C.I. [76.2-99.9]). The repeatability (accordance) and reproducibility (concordance) were 100% for seropositive samples but were lower for two of the seronegative samples (45% and 89% respectively). The analytical sensitivity, evaluated by testing positive sera at increasing dilutions was better for the BT LFT compared to some commercial ELISAs. Seroconversion of an infected sheep was detected at 4 days post infection. Analytical specificity was impaired by cross-reactions observed with some of the samples seropositive for Epizootic Haemorrhagic Disease Virus (EHDV). The agreement (Cohen's kappa) between the LFT and a commercial BT competitive ELISA was 0.79 (95% CI [0.62-0.95]). Based on these results, it can be concluded that the BT LFT device is a rapid and sensitive first-line serological test that can be used in the field, especially in areas endemic for the disease where there is a lack of diagnostic facilities. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Determination of perfluorinated alkyl acid concentrations in human serum and milk standard reference materials.

    PubMed

    Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M

    2010-05-01

    Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.

  13. Results of a European interlaboratory comparison on CO2 sorption on activated carbon and coals

    NASA Astrophysics Data System (ADS)

    Gensterblum, Yves; Busch, Andreas; Krooss, Bernhard; de Weireld, Guy; Billemont, Pierre; van Hemert, Patrick; Wolf, Karl-Heinz

    2013-04-01

    For the assessment of CO2 storage in coal seams or enhanced coalbed methane production (ECBM), the sorption properties of natural coals are important parameters. Since more and more laboratories worldwide are concerned with measurements of gas sorption on coal it is indispensable to establish quality standards for such experiments. The first two interlaboratory studies on CO2 sorption on coal (Goodman et al. 2004, 2007) revealed a poor agreement of sorption isotherms among the participating laboratories, particularly in the high-pressure range. During the MOVECBM (http://www.movecbm.eu/) project funded by the European Commission (6th framework), an interlaboratory comparison of CO2 sorption on selected coals and activated carbon was initiated. Measurements were performed on dry samples at 45° C using the manometric and the gravimetric method. up to a final pressure of 15 MPa. The first set of high-pressure sorption measurements was performed on a Filtrasorb 400 activated carbon sample in order to minimise heterogeneity effects and to optimize the experimental procedures for the individual (manometric or gravimetric) methods (Gensterblum et al. 2009). Since comparability for the activated carbon was excellent, the measurements were continued using natural coals of various rank (anthracite, bituminous coal and lignite) to study the influence of heterogeneities and varying starting conditions on the CO2 sorption properties (Gensterblum et al. 2010). Compared to the poor reproducibility observed in previous interlaboratory studies (Goodman et al., 2004, 2007) this European study showed excellent agreement (<5 % deviation) among the participating laboratories with good repeatability. The sorption data and technical information on the different experimental setups have been used to investigate errors and potential pitfalls in the assessment of high-pressure CO2 sorption isotherms. References Gensterblum Y., P. van Hemert, P. Billemont, A. Busch, B.M. Krooss, G. de Weireld, D. Prinz , K.-H.A.A. Wolf, "European inter-laboratory comparison of high pressure CO2 sorption isotherms. II: natural coals" IJCG, 2010, 84, 115-124 Gensterblum Y., P. van Hemert, P. Billemont, A. Busch, D. Charriére, D. Li, B.M. Krooss, G. de Weireld, D. Prinz , K.-H.A.A. Wolf, "European inter-laboratory comparison of high pressure CO2 sorption isotherms. I: Activated carbon" Carbon 47 ( 2009 ) 2958 -2969 Goodman, A.L., Busch, A., Duffy, G., Fitzgerald, J.E., Gasem, K.A.M., Gensterblum, Y., Krooss, B.M., Levy, J., Ozdemir, E., Pan, Z., Robinson, Jr., R.L., Schroeder, K., Sudibandriyo, M., White, C. (2004). An Inter-laboratory Comparison of CO2 Isotherms Measured on Argonne Premium Coal Samples. Energy and Fuels 18, 1175-1182. Goodman, A.L., Busch, A., Day, S., Duffy, G.J., Fitzgerald, J.E., Gasem, K.A.M., Gensterblum, Y., Hartman, C., Krooss, B.M., Pan, Z., Pratt, T., Robinson, Jr., R.L., Romanov, V., Sakurovs, R., Schroeder, K., Sudibandriyo, M., White, C.M. (2007) "Inter-laboratory Comparison II: CO2 Isotherms Measured on Moisture-Equilibrated Argonne Premium Coals at 55oC and 15 MPa", International Journal of Coal Geology 72, 153-164.

  14. Inter-laboratory comparisons of hexenuronic acid measurements in kraft eucalyptus pulps using a UV-Vis spectroscopic method

    Treesearch

    J.Y. Zhu; H.F Zhou; Chai X.S.; Donna Johannes; Richard Pope; Cristina Valls; M. Blanca Roncero

    2014-01-01

    An inter-laboratory comparison of a UV-Vis spectroscopic method (TAPPI T 282 om-13 “Hexeneuronic acid content of chemical pulp”) for hexeneuronic acid measurements was conducted using three eucalyptus kraft pulps. The pulp samples were produced in a laboratory at kappa numbers of approximately 14, 20, and 35. The hexeneuronic acid contents of the three pulps were...

  15. Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.

    PubMed

    Plappert-Helbig, Ulla; Guérard, Melanie

    2015-12-01

    To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.

  16. The breaking load method - Results and statistical modification from the ASTM interlaboratory test program

    NASA Technical Reports Server (NTRS)

    Colvin, E. L.; Emptage, M. R.

    1992-01-01

    The breaking load test provides quantitative stress corrosion cracking data by determining the residual strength of tension specimens that have been exposed to corrosive environments. Eight laboratories have participated in a cooperative test program under the auspices of ASTM Committee G-1 to evaluate the new test method. All eight laboratories were able to distinguish between three tempers of aluminum alloy 7075. The statistical analysis procedures that were used in the test program do not work well in all situations. An alternative procedure using Box-Cox transformations shows a great deal of promise. An ASTM standard method has been drafted which incorporates the Box-Cox procedure.

  17. An interlaboratory comparison programme on radio frequency electromagnetic field measurements: the second round of the scheme.

    PubMed

    Nicolopoulou, E P; Ztoupis, I N; Karabetsos, E; Gonos, I F; Stathopulos, I A

    2015-04-01

    The second round of an interlaboratory comparison scheme on radio frequency electromagnetic field measurements has been conducted in order to evaluate the overall performance of laboratories that perform measurements in the vicinity of mobile phone base stations and broadcast antenna facilities. The participants recorded the electric field strength produced by two high frequency signal generators inside an anechoic chamber in three measurement scenarios with the antennas transmitting each time different signals at the FM, VHF, UHF and GSM frequency bands. In each measurement scenario, the participants also used their measurements in order to calculate the relative exposure ratios. The results were evaluated in each test level calculating performance statistics (z-scores and En numbers). Subsequently, possible sources of errors for each participating laboratory were discussed, and the overall evaluation of their performances was determined by using an aggregated performance statistic. A comparison between the two rounds proves the necessity of the scheme. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Final report of EURAMET 1197: Supplementary bilateral comparison of hydraulic gauge pressure standards up to 50 MPa

    NASA Astrophysics Data System (ADS)

    Durgut, Yasin; Petrovski, Nenad; Kacarski, Vanco

    2012-01-01

    Interlaboratory comparisons are important for the laboratories to assess their own measurement capability. It is equally important for the accreditation bodies and assessors during the audit process of a laboratory to judge whether the laboratory is doing well. As per accreditation rules, it is mandatory for the testing and calibration laboratories to participate in such comparisons from time to time. In this report, results of the bilateral interlaboratory comparison in pressure area in hydraulic media up to 50 MPa gauge between UME (Turkey) and BOM (The FYR of Macedonia) are presented. The artefact used for the comparison was a digital pressure calibrator and its drift was taken into account in the calculation. Results show that all En values lie in acceptable limits. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by EURAMET, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  19. Tools to minimize interlaboratory variability in vitellogenin gene expression monitoring programs

    USGS Publications Warehouse

    Jastrow, Aaron; Gordon, Denise A.; Auger, Kasie M.; Punska, Elizabeth C.; Arcaro, Kathleen F.; Keteles, Kristen; Winkelman, Dana L.; Lattier, David; Biales, Adam; Lazorchak, James M.

    2017-01-01

    The egg yolk precursor protein vitellogenin is widely used as a biomarker of estrogen exposure in male fish. However, standardized methodology is lacking and little is known regarding the reproducibility of results among laboratories using different equipment, reagents, protocols, and data analysis programs. To address this data gap we tested the reproducibility across laboratories to evaluate vitellogenin gene (vtg) expression and assessed the value of using a freely available software data analysis program. Samples collected from studies of male fathead minnows (Pimephales promelas) exposed to 17α-ethinylestradiol (EE2) and minnows exposed to processed wastewater effluent were evaluated for vtg expression in 4 laboratories. Our results indicate reasonable consistency among laboratories if the free software for expression analysis LinRegPCR is used, with 3 of 4 laboratories detecting vtg in fish exposed to 5 ng/L EE2 (n = 5). All 4 laboratories detected significantly increased vtg levels in 15 male fish exposed to wastewater effluent compared with 15 male fish held in a control stream. Finally, we were able to determine that the source of high interlaboratory variability from complementary deoxyribonucleic acid (cDNA) to quantitative polymerase chain reaction (qPCR) analyses was the expression analysis software unique to each real-time qPCR machine. We successfully eliminated the interlaboratory variability by reanalyzing raw fluorescence data with independent freeware, which yielded cycle thresholds and polymerase chain reaction (PCR) efficiencies that calculated results independently of proprietary software. Our results suggest that laboratories engaged in monitoring programs should validate their PCR protocols and analyze their gene expression data following the guidelines established in the present study for all gene expression biomarkers. 

  20. First European interlaboratory comparison of tetracycline and age determination with red fox teeth following oral rabies vaccination programs.

    PubMed

    Robardet, Emmanuelle; Demerson, Jean-Michel; Andrieu, Sabrina; Cliquet, Florence

    2012-10-01

    The first European interlaboratory comparison of tetracycline and age determination with red fox (Vulpes vulpes) tooth samples was organized by the European Union Reference Laboratory for rabies. Performance and procedures implemented by member states were compared. These techniques are widely used to monitor bait uptake in European oral rabies vaccination campaigns. A panel of five red fox half-mandibles comprising one weak positive juvenile sample, two positive adult samples, one negative juvenile sample, and one negative adult sample were sent, along with a technical questionnaire, to 12 laboratories participating on a voluntary basis. The results of only three laboratories (25%) were 100% correct. False-negative results were more frequently seen in weak positive juvenile samples (58%) but were infrequent in positive adult samples (4%), probably due to differences in the ease of reading the two groups of teeth. Four laboratories (44%) had correct results for age determination on all samples. Ages were incorrectly identified in both adult and juvenile samples, with 11 and 17% of discordant results, respectively. Analysis of the technical questionnaires in parallel with test results suggested that all laboratories cutting mandible sections between the canine and first premolar obtained false results. All the laboratories using longitudinal rather than transverse sections and those not using a mounting medium also produced false results. Section thickness appeared to affect the results; no mistakes were found in laboratories using sections <150 μm thick. Factors having a potential impact on the success of laboratories were discussed, and recommendations proposed. Such interlaboratory trials underline the importance of using standardized procedures for biomarker detection in oral rabies vaccination campaigns. Several changes can be made to improve analysis quality and increase the comparability of bait uptake frequencies among member states.

  1. Extra-analytical quality indicators and laboratory performances.

    PubMed

    Sciacovelli, Laura; Aita, Ada; Plebani, Mario

    2017-07-01

    In the last few years much progress has been made in raising the awareness of laboratory medicine professionals about the effectiveness of quality indicators (QIs) in monitoring, and improving upon, performances in the extra-analytical phases of the Total Testing Process (TTP). An effective system for management of QIs includes the implementation of an internal assessment system and participation in inter-laboratory comparison. A well-designed internal assessment system allows the identification of critical activities and their systematic monitoring. Active participation in inter-laboratory comparison provides information on the performance level of one laboratory with respect to that of other participating laboratories. In order to guarantee the use of appropriate QIs and facilitate their implementation, many laboratories have adopted the Model of Quality Indicators (MQI) proposed by Working Group "Laboratory Errors and Patient Safety" (WG-LEPS) of IFCC, since 2008, which is the result of international consensus and continuous experimentation, and updating to meet new, constantly emerging needs. Data from participating laboratories are collected monthly and reports describing the statistical results and evaluating laboratory data, utilizing the Six Sigma metric, issued regularly. Although the results demonstrate that the processes need to be improved upon, overall the comparison with data collected in 2014 shows a general stability of quality levels and that an improvement has been achieved over time for some activities. The continuous monitoring of QI data allows identification all possible improvements, thus highlighting the value of participation in the inter-laboratory program proposed by WG-LEPS. The active participation of numerous laboratories will guarantee an ever more significant State-of-the-Art, promote the reduction of errors and improve quality of the TTP, thus guaranteeing patient safety. Copyright © 2017. Published by Elsevier Inc.

  2. Development of an in vitro skin sensitization test using human cell lines; human Cell Line Activation Test (h-CLAT). II. An inter-laboratory study of the h-CLAT.

    PubMed

    Sakaguchi, H; Ashikaga, T; Miyazawa, M; Yoshida, Y; Ito, Y; Yoneyama, K; Hirota, M; Itagaki, H; Toyoda, H; Suzuki, H

    2006-08-01

    Recent regulatory changes have placed a major emphasis on in vitro safety testing and alternative models. In regard to skin sensitization tests, dendritic cells (DCs) derived from human peripheral blood have been considered in the development of new in vitro alternatives. Human cell lines have been also reported recently. In our previous study, we suggested that measuring CD86 and/or CD54 expression on THP-1 cells (human monocytic leukemia cell line) could be used as an in vitro skin sensitization method. An inter-laboratory study among two laboratories was undertaken in Japan in order to further develop an in vitro skin sensitization model. In the present study, we used two human cell lines: THP-1 and U-937 (human histiocytic lymphoma cell line). First we optimized our test protocol (refer to the related paper entitled "optimization of the h-CLAT protocol" within this journal) and then we did an inter-laboratory validation with nine chemicals using the optimized protocol. We measured the expression of CD86 and CD54 on the above cells using flow cytometry after a 24h and 48h exposure to six known allergens (e.g., DNCB, pPD, NiSO(4)) and three non-allergens (e.g., SLS, tween 80). For the sample test concentration, four doses (0.1x, 0.5x, 1x, and 2x of the 50% inhibitory concentration (IC(50))) were evaluated. IC(50) was calculated using MTT assay. We found that allergens/non-allergens were better predicted using THP-1 cells compared to U-937 cells following a 24 h and a 48 h exposure. We also found that the 24h treatment time tended to have a better accuracy than the 48 h treatment time for THP-1 cells. Expression of CD86 and CD54 were good predictive markers for THP-1 cells, but for U-937 cells, expression of CD86 was a better predictor than CD54, at the 24h and the 48 h treatment time. The accuracy also improved when both markers (CD86 and CD54) were used as compared with a single marker for THP-1 cells. Both laboratories gave a good prediction of allergen/non-allergen, especially using THP-1 cells. These results suggest that our method, human Cell Line Activation Test (h-CLAT), using human cell lines THP-1 and U-937, but especially THP-1 cells at 24h treatment, may be a useful in vitro skin sensitization model to predict various contact allergens.

  3. Correlation to FVIII:C in Two Thrombin Generation Tests: TGA-CAT and INNOVANCE ETP.

    PubMed

    Ljungkvist, Marcus; Berndtsson, Maria; Holmström, Margareta; Mikovic, Danijela; Elezovic, Ivo; Antovic, Jovan P; Zetterberg, Eva; Berntorp, Erik

    2017-01-01

    Several thrombin-generation tests are available, but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A. The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method. Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman's rank correlation test. For determination of the TGA-CAT inter-laboratory variability, Bland-Altman plots were used. The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0.701 and r=0.734 respectively.The correlation between the two methods was r=0.546.When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them.The variability of the TGA-CAT results performed at the two centers was reduced after normalization; before normalization, 29% of values showed less than ±10% difference while after normalization the number increased to 41%. Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation with each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.

  4. Effect of incubation temperature and time on the precision of data generated by antibiotic disc diffusion assays.

    PubMed

    Smith, P; Kronvall, G

    2015-07-01

    The influence on the precision of disc diffusion data of the conditions under which the tests were performed was examined by analysing multilaboratory data sets generated after incubation at 35 °C for 18 h, at 28 °C for 24 h and 22 °C for 24 h and 48 h. Analyses of these data sets demonstrated that precision was significantly and progressively decreased as the test temperature was reduced from 35 to 22 °C. Analysis of the data obtained at 22 °C also showed the precision was inversely related to the time of incubation. Temperature and time related decreases in precision were not related to differences in the mean zone sizes of the data sets obtained under these test conditions. Analysis of the zone data obtained at 28 and 22 °C as single laboratory sets demonstrated that reductions of incubation temperature resulted in significant increases in both intralaboratory and interlaboratory variation. Increases in incubation time at 22 °C were, however, associated with statistically significant increases in interlaboratory variation but not with any significant increase in intralaboratory variation. The significance of these observations for the establishment of the acceptable limits of precision of data sets that can be used for the setting of valid epidemiological cut-off values is discussed. © 2014 John Wiley & Sons Ltd.

  5. Innovative Alternatives to Lifting Overturned Military Vehicles

    DTIC Science & Technology

    2014-04-25

    NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) United States Air Force Academy,Washington,DC,20301 8...PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR...Initial testing of the prototype involved using a SATEC load frame to apply a load. As previously stated, during the first test the design failed

  6. Amino acid racemization dating of fossil bones, I. inter-laboratory comparison of racemization measurements

    USGS Publications Warehouse

    Bada, J.L.; Hoopes, E.; Darling, D.; Dungworth, G.; Kessels, H.J.; Kvenvolden, K.A.; Blunt, D.J.

    1979-01-01

    Enantiomeric measurements for aspartic acid, glutamic acid, and alanine in twenty-one different fossil bone samples have been carried out by three different laboratories using different analytical methods. These inter-laboratory comparisons demonstrate that D/L aspartic acid measurements are highly reproducible, whereas the enantiomeric measurements for the other amino acids show a wide variation between the three laboratories. At present, aspartic acid measurements are the most suitable for racemization dating of bone because of their superior analytical precision. ?? 1979.

  7. Accuracy of trace element determinations in alternate fuels

    NASA Technical Reports Server (NTRS)

    Greenbauer-Seng, L. A.

    1980-01-01

    A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

  8. Oxidative induction time -- A review of DSC experimental effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaine, R.L.; Lundgren, C.J.; Harris, M.B.

    1997-12-31

    Over the past several years, a number of ASTM committees have explored a wide variety of experimental parameters affecting the oxidative induction time (OIT) test method in an attempt to improve its intra- and inter-laboratory precision. These studies have identified test temperature precision as a key parameter affecting OIT precision. Other parameters of importance are oxygen flow rate, specimen size, specimen pan type, oxygen pressure and catalyst effects. The work of Kuck, Bowmer, Riga, Tikuisis and Thomas are reviewed as well as the collective work of ASTM Committees E37, D2, D9 and D35.

  9. Test Operations Procedure (TOP) 08-2-188 Chemical Point Detector Vapor Testing

    DTIC Science & Technology

    2018-04-27

    Evaluation Command 6617 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S...AND EVALUATION COMMAND TEST OPERATIONS PROCEDURE *Test Operations Procedure 08-2-188 27 April 2018 DTIC AD No. CHEMICAL POINT DETECTOR VAPOR...188 27 April 2018 2 1. SCOPE. This Test Operations Procedure (TOP), which has been endorsed by the Test and Evaluation Capabilities and

  10. Centrally Determined Standardization of Flow Cytometry Methods Reduces Interlaboratory Variation in a Prospective Multicenter Study.

    PubMed

    Westera, Liset; van Viegen, Tanja; Jeyarajah, Jenny; Azad, Azar; Bilsborough, Janine; van den Brink, Gijs R; Cremer, Jonathan; Danese, Silvio; D'Haens, Geert; Eckmann, Lars; Faubion, William; Filice, Melissa; Korf, Hannelie; McGovern, Dermot; Panes, Julian; Salas, Azucena; Sandborn, William J; Silverberg, Mark S; Smith, Michelle I; Vermeire, Severine; Vetrano, Stefania; Shackelton, Lisa M; Stitt, Larry; Jairath, Vipul; Levesque, Barrett G; Spencer, David M; Feagan, Brian G; Vande Casteele, Niels

    2017-11-02

    Flow cytometry (FC) aids in characterization of cellular and molecular factors involved in pathologic immune responses. Although FC has potential to facilitate early drug development in inflammatory bowel disease, interlaboratory variability limits its use in multicenter trials. Standardization of methods may address this limitation. We compared variability in FC-aided quantitation of T-cell responses across international laboratories using three analytical strategies. Peripheral blood mononuclear cells (PBMCs) were isolated from three healthy donors, stimulated with phorbol 12-myristate 13-acetate and ionomycin at a central laboratory, fixed, frozen, and shipped to seven international laboratories. Permeabilization and staining was performed in triplicate at each laboratory using a common protocol and centrally provided reagents. Gating was performed using local gating with a local strategy (LGLS), local gating with a central strategy (LGCS), and central gating (CG). Median cell percentages were calculated across triplicates and donors, and reported for each condition and strategy. The coefficient of variation (CV) was calculated across laboratories. Between-strategy comparisons were made using a two-way analysis of variance adjusting for donor. Mean interlaboratory CV ranged from 1.8 to 102.1% depending on cell population and gating strategy (LGLS, 4.4-102.1%; LGCS, 10.9-65.6%; CG, 1.8-20.9%). Mean interlaboratory CV differed significantly across strategies and was consistently lower with CG. Central gating was the only strategy with mean CVs consistently lower than 25%, which is a proposed standard for pharmacodynamic and exploratory biomarker assays.

  11. Sample integrity evaluation and EPA method 325B interlaboratory comparison for select volatile organic compounds collected diffusively on Carbopack X sorbent tubes

    NASA Astrophysics Data System (ADS)

    Oliver, Karen D.; Cousett, Tamira A.; Whitaker, Donald A.; Smith, Luther A.; Mukerjee, Shaibal; Stallings, Casson; Thoma, Eben D.; Alston, Lillian; Colon, Maribel; Wu, Tai; Henkle, Stacy

    2017-08-01

    A sample integrity evaluation and an interlaboratory comparison were conducted in application of U.S. Environmental Protection Agency (EPA) Methods 325A and 325B for diffusively monitoring benzene and other selected volatile organic compounds (VOCs) using Carbopack X sorbent tubes. To evaluate sample integrity, VOC samples were refrigerated for up to 240 days and analyzed using thermal desorption/gas chromatography-mass spectrometry at the EPA Office of Research and Development laboratory in Research Triangle Park, NC, USA. For the interlaboratory comparison, three commercial analytical laboratories were asked to follow Method 325B when analyzing samples of VOCs that were collected in field and laboratory settings for EPA studies. Overall results indicate that the selected VOCs collected diffusively on sorbent tubes generally were stable for 6 months or longer when samples were refrigerated. This suggests the specified maximum 30-day storage time of VOCs collected diffusively on Carbopack X passive samplers and analyzed using Method 325B might be able to be relaxed. Interlaboratory comparison results were in agreement for the challenge samples collected diffusively in an exposure chamber in the laboratory, with most measurements within ±25% of the theoretical concentration. Statistically significant differences among laboratories for ambient challenge samples were small, less than 1 part per billion by volume (ppbv). Results from all laboratories exhibited good precision and generally agreed well with each other.

  12. Evaluating diagnostic tests for bovine tuberculosis in the southern part of Germany: A latent class analysis

    PubMed Central

    Knubben-Schweizer, Gabriela; Döpfer, Dörte; Groll, Andreas; Hafner-Marx, Angela; Hörmansdorfer, Stefan; Sauter-Louis, Carola; Straubinger, Reinhard K.; Zimmermann, Pia; Hartnack, Sonja

    2017-01-01

    Germany has been officially free of bovine tuberculosis since 1996. However, in the last years there has been an increase of bovine tuberculosis cases, particularly in the southern part of Germany, in the Allgäu region. As a consequence a one-time tuberculosis surveillance program was revisited with different premortal and postmortal tests. The aim of this paper was to estimate diagnostic sensitivities and specificities of the different tests used within this surveillance program. In the absence of a perfect test with 100% sensitivity and 100% specificity, thus in the absence of a gold standard, a Bayesian latent class approach with two different datasets was performed. The first dataset included 389 animals, tested with single intra-dermal comparative cervical tuberculin (SICCT) test, PCR and pathology; the second dataset contained 175 animals, tested with single intra-dermal cervical tuberculin (SICT) test, Bovigam® assay, pathology and culture. Two-way conditional dependencies were considered within the models. Additionally, inter-laboratory agreement (five officially approved laboratories) of the Bovigam® assay was assessed with Cohen's kappa test (21 blood samples). The results are given in posterior means and 95% credibility intervals. The specificities of the SICT test, SICCT test, PCR and pathology ranged between 75.8% [68.8–82.2%] and 99.0% [96.8–100%]. The Bovigam® assay stood out with a very low specificity (6.9% [3.6–11.1%]), though it had the highest sensitivity (95.7% [91.3–99.2%]). The sensitivities of the SICCT test, PCR, SICT test, pathology and culture varied from 57.8% [48.0–67.6%] to 88.9% [65.5–99.7%]. The prevalences were 19.8% [14.6–26.5%] (three-test dataset) and 7.7% [4.2–12.3%] (four-test dataset). Among all pairwise comparisons the highest agreement was 0.62 [0.15–1]). In conclusion, the specificity of the Bovigam® assay and the inter-laboratory agreement were lower than expected. PMID:28640908

  13. Clinical Validation of Anyplex II HPV HR Detection Test for Cervical Cancer Screening in Korea.

    PubMed

    Jung, Sunkyung; Lee, Byungdoo; Lee, Kap No; Kim, Yonggoo; Oh, Eun-Jee

    2016-03-01

    The Anyplex II HPV HR detection kit (Seegene Inc, Seoul, Korea) is a new, multiplex, real-time polymerase chain reaction assay to detect individual 14 high-risk (HR) human papillomavirus (HPV) types in a single tube. To evaluate the clinical performance of the HPV HR kit in predicting high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse in cervical cancer screening. We analyzed 1137 cervical samples in Huro Path medium (CelltraZone, Seoul, Korea) from Korean women. The clinical performance of the HPV HR kit was compared with Hybrid Capture 2 (Qiagen, Valencia, California) using the noninferiority score test in a routine cervical cancer screening setting. The intralaboratory and interlaboratory agreements of HPV HR were also evaluated. Overall agreement between the 2 assays was 92.4% (1051 of 1137) with a κ value of 0.787. Clinical sensitivity of HPV HR for high-grade squamous intraepithelial lesions and cervical intraepithelial lesions grade 2 or worse was 94.4% (95% confidence interval [CI], 89.2-99.7) and 92.5% (95% CI, 84.3-100.0), respectively. The respective values for Hybrid Capture 2 were 93.1% (95% CI, 87.2-98.9) and 87.5% (95% CI, 77.3-99.7). Clinical sensitivity and specificity of HPV HR were not inferior to those of Hybrid Capture 2 (P = .005 and P = .04, respectively). The HPV HR showed good intralaboratory and interlaboratory reproducibility at 98.0% (κ = 0.953) and 97.4% (κ = 0.940), respectively. The HPV HR demonstrates comparable performance to the Hybrid Capture 2 test and can be useful for HPV-based cervical cancer screening testing.

  14. Application of a Novel DCPD Adjustment Method for the J-R Curve Characterization: A study based on ORNL and ASTM Interlaboratory Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Xiang; Sokolov, Mikhail A; Nanstad, Randy K

    Material fracture toughness in the fully ductile region can be described by a J-integral vs. crack growth resistance curve (J-R curve). As a conventional J-R curve measurement method, the elastic unloading compliance (EUC) method becomes impractical for elevated temperature testing due to relaxation of the material and friction induced back-up shape of the J-R curve. One alternative solution of J-R curve testing applies the Direct Current Potential Drop (DCPD) technique for measuring crack extension. However, besides crack growth, potential drop can also be influenced by plastic deformation, crack tip blunting, etc., and uncertainties exist in the current DCPD methodology especiallymore » in differentiating potential drop due to stable crack growth and due to material deformation. Thus, using DCPD for J-R curve determination remains a challenging task. In this study, a new adjustment procedure for applying DCPD to derive the J-R curve has been developed for conventional fracture toughness specimens, including compact tension, three-point bend, and disk-shaped compact specimens. Data analysis has been performed on Oak Ridge National Laboratory (ORNL) and American Society for Testing and Materials (ASTM) interlaboratory results covering different specimen thicknesses, test temperatures, and materials, to evaluate the applicability of the new DCPD adjustment procedure for J-R curve characterization. After applying the newly-developed procedure, direct comparison between the DCPD method and the normalization method on the same specimens indicated close agreement for the overall J-R curves, as well as the provisional values of fracture toughness near the onset of ductile crack extension, Jq, and of tearing modulus.« less

  15. Statistical evaluation of an inductively coupled plasma atomic emission spectrometric method for routine water quality testing

    USGS Publications Warehouse

    Garbarino, J.R.; Jones, B.E.; Stein, G.P.

    1985-01-01

    In an interlaboratory test, inductively coupled plasma atomic emission spectrometry (ICP-AES) was compared with flame atomic absorption spectrometry and molecular absorption spectrophotometry for the determination of 17 major and trace elements in 100 filtered natural water samples. No unacceptable biases were detected. The analysis precision of ICP-AES was found to be equal to or better than alternative methods. Known-addition recovery experiments demonstrated that the ICP-AES determinations are accurate to between plus or minus 2 and plus or minus 10 percent; four-fifths of the tests yielded average recoveries of 95-105 percent, with an average relative standard deviation of about 5 percent.

  16. Participation on official proficiency test of the OPCW: case study of Brazilian Army – IDQBRN

    NASA Astrophysics Data System (ADS)

    Silva, T. C.; Ferreira, C. N.; Cardozo, M.; de Paula, R. L.

    2018-03-01

    In recent years, Brazil has been the scene of international events, gaining worldwide repercussion. However, this increases the risk of terrorist attacks using chemical warfare agents. It brings the need to achieve proficiency to do a quick and unequivocal identification of these dangerous compounds. Thinking about it, the Laboratory of Chemical Analyzes (LAQ) of Brazilian Army has participated since the end of 2010 in the interlaboratory tests promoted by the Organisation for the Prohibition of Chemical Weapons (OPCW). In this article, we discuss about the participation of LAQ in the 40th OPCW Proficiency Test, one more step in the way to become a laboratory designated by OPCW and an international reference.

  17. Toward Reliable Lipoprotein Particle Predictions from NMR Spectra of Human Blood: An Interlaboratory Ring Test.

    PubMed

    Monsonis Centelles, Sandra; Hoefsloot, Huub C J; Khakimov, Bekzod; Ebrahimi, Parvaneh; Lind, Mads V; Kristensen, Mette; de Roo, Niels; Jacobs, Doris M; van Duynhoven, John; Cannet, Claire; Fang, Fang; Humpfer, Eberhard; Schäfer, Hartmut; Spraul, Manfred; Engelsen, Søren B; Smilde, Age K

    2017-08-01

    Lipoprotein profiling of human blood by 1 H nuclear magnetic resonance (NMR) spectroscopy is a rapid and promising approach to monitor health and disease states in medicine and nutrition. However, lack of standardization of measurement protocols has prevented the use of NMR-based lipoprotein profiling in metastudies. In this study, a standardized NMR measurement protocol was applied in a ring test performed across three different laboratories in Europe on plasma and serum samples from 28 individuals. Data was evaluated in terms of (i) spectral differences, (ii) differences in LPD predictions obtained using an existing prediction model, and (iii) agreement of predictions with cholesterol concentrations in high- and low-density lipoproteins (HDL and LDL) particles measured by standardized clinical assays. ANOVA-simultaneous component analysis (ASCA) of the ring test spectral ensemble that contains methylene and methyl peaks (1.4-0.6 ppm) showed that 97.99% of the variance in the data is related to subject, 1.62% to sample type (serum or plasma), and 0.39% to laboratory. This interlaboratory variation is in fact smaller than the maximum acceptable intralaboratory variation on quality control samples. It is also shown that the reproducibility between laboratories is good enough for the LPD predictions to be exchangeable when the standardized NMR measurement protocol is followed. With the successful implementation of this protocol, which results in reproducible prediction of lipoprotein distributions across laboratories, a step is taken toward bringing NMR more into scope of prognostic and diagnostic biomarkers, reducing the need for less efficient methods such as ultracentrifugation or high-performance liquid chromatography (HPLC).

  18. Interlaboratory studies and initiatives developing standards for proteomics

    PubMed Central

    Ivanov, Alexander R.; Colangelo, Christopher M.; Dufresne, Craig P.; Friedman, David B.; Lilley, Kathryn S.; Mechtler, Karl; Phinney, Brett S.; Rose, Kristie L.; Rudnick, Paul A.; Searle, Brian C.; Shaffer, Scott A.; Weintraub, Susan T.

    2013-01-01

    Proteomics is a rapidly transforming interdisciplinary field of research that embraces a diverse set of analytical approaches to tackle problems in fundamental and applied biology. This view-point article highlights the benefits of interlaboratory studies and standardization initiatives to enable investigators to address many of the challenges found in proteomics research. Among these initiatives, we discuss our efforts on a comprehensive performance standard for characterizing PTMs by MS that was recently developed by the Association of Biomolecular Resource Facilities (ABRF) Proteomics Standards Research Group (sPRG). PMID:23319436

  19. Scaled Composites' Doug Shane examines the screen of his ground control station during tests in New Mexico. Shane used this configuration as the ground control station to remotely pilot the Proteus aircraft during a NASA sponsored series of tests.

    NASA Image and Video Library

    2002-03-13

    Scaled Composites' Doug Shane examines the screen of his ground control station during tests in New Mexico. Shane used this configuration as the ground control station to remotely pilot the Proteus aircraft during a NASA sponsored series of tests.

  20. ORANGES evaluation final report appendices : for the US DOT sponsored evaluation of the ORANGES electronic payment systems field operational test

    DOT National Transportation Integrated Search

    2004-12-06

    These are the appendices for the report describing the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evalua...

  1. ORANGES evaluation final report : for the US DOT sponsored evaluation of the ORANGES electronic payment systems field operational test

    DOT National Transportation Integrated Search

    2004-12-06

    This report describes the findings of the US DOT-sponsored evaluation of the Orlando (Florida) ORANGES multi-modal Field Operational Test (FOT); the report includes: a background description of the ORANGES FOT; the Evaluation Strategy and Plan, which...

  2. Development of a new test cell to measure cumulative permeation of water-insoluble pesticides with low vapor pressure through protective clothing and glove materials

    PubMed Central

    SHAW, Anugrah; COLEONE-CARVALHO, Ana Carla; HOLLINGSHURST, Julien; DRAPER, Michael; MACHADO NETO, Joaquim Gonçalves

    2017-01-01

    A collaborative approach, involving resources and expertise from several countries, was used to develop a test cell to measure cumulative permeation by a solid-state collection technique. The new technique was developed to measure the permeation of pesticide active ingredients and other chemicals with low vapor pressure that would otherwise be difficult to test via standard techniques. The development process is described and the results from the final chosen test method are reported. Inter-laboratory studies were conducted to further refine the new method and determine repeatability and reliability. The revised test method has been approved as a new ISO/EN standard to measure permeation of chemicals with low vapor pressure and/or solubility in water. PMID:29033403

  3. Centrally Determined Standardization of Flow Cytometry Methods Reduces Interlaboratory Variation in a Prospective Multicenter Study

    PubMed Central

    Westera, Liset; van Viegen, Tanja; Jeyarajah, Jenny; Azad, Azar; Bilsborough, Janine; van den Brink, Gijs R; Cremer, Jonathan; Danese, Silvio; D'Haens, Geert; Eckmann, Lars; Faubion, William; Filice, Melissa; Korf, Hannelie; McGovern, Dermot; Panes, Julian; Salas, Azucena; Sandborn, William J; Silverberg, Mark S; Smith, Michelle I; Vermeire, Severine; Vetrano, Stefania; Shackelton, Lisa M; Stitt, Larry; Jairath, Vipul; Levesque, Barrett G; Spencer, David M; Feagan, Brian G; Vande Casteele, Niels

    2017-01-01

    Objectives: Flow cytometry (FC) aids in characterization of cellular and molecular factors involved in pathologic immune responses. Although FC has potential to facilitate early drug development in inflammatory bowel disease, interlaboratory variability limits its use in multicenter trials. Standardization of methods may address this limitation. We compared variability in FC-aided quantitation of T-cell responses across international laboratories using three analytical strategies. Methods: Peripheral blood mononuclear cells (PBMCs) were isolated from three healthy donors, stimulated with phorbol 12-myristate 13-acetate and ionomycin at a central laboratory, fixed, frozen, and shipped to seven international laboratories. Permeabilization and staining was performed in triplicate at each laboratory using a common protocol and centrally provided reagents. Gating was performed using local gating with a local strategy (LGLS), local gating with a central strategy (LGCS), and central gating (CG). Median cell percentages were calculated across triplicates and donors, and reported for each condition and strategy. The coefficient of variation (CV) was calculated across laboratories. Between-strategy comparisons were made using a two-way analysis of variance adjusting for donor. Results: Mean interlaboratory CV ranged from 1.8 to 102.1% depending on cell population and gating strategy (LGLS, 4.4–102.1% LGCS, 10.9–65.6% CG, 1.8–20.9%). Mean interlaboratory CV differed significantly across strategies and was consistently lower with CG. Conclusions: Central gating was the only strategy with mean CVs consistently lower than 25%, which is a proposed standard for pharmacodynamic and exploratory biomarker assays. PMID:29095427

  4. Interlaboratory comparison of mineral constituents in a sample from the Herrin (No. 6) coal bed from Illinois

    USGS Publications Warehouse

    Finkelman, Robert B.; Fiene, F.L.; Miller, R.N.; Simon, F.O.

    1984-01-01

    Approximately 20 kg of the Herrin (No. 6) coal was collected from a strip mine in St. Clair County, Ill. A 10-kg portion was ground to -60 mesh, homogenized, and riffled into 128 splits of 70-80 g each. Homogeneity of these splits was confirmed by moisture, ash, and sulfur analyses of six randomly selected splits. Results of these analyses were within the ASTM (American Society for Testing and Materials) guidelines for interlaboratory precision. Splits of the Herrin (No. 6) coal were then transmitted to more than 30 laboratories for analysis. Low-temperature plasma oxidation was used to isolate inorganic matter for quantitative chemical and mineralogical analysis. Despite a wide variation in ashing conditions, only minor variations in ash yields were obtained; these variations were attributed to differences in operating temperature and moisture content. Mineralogical analyses of low-temperature ash (LTA) concentrates prepared by five different laboratories indicated variations within the limits of analytical error. The mean values, in weight percent, for the major minerals are as follows: calcite, 9; quartz, 20; pyrite, 23; kaolinite, 14; and illite+mixed-layer clays, 31. Normative mineralogical calculations and Fourier transform infrared analysis (FTIR) yielded results similar to those obtained from X-ray diffraction (XRD). Choosing appropriate mineral standards was found to be critical for the proper use of analytical techniques such as XRD and FTIR. Good interlaboratory agreement was obtained for most major, minor, and trace elements despite differences in analytical procedures and in the type of sample analyzed (coal, high-temperature ash, or LTA). Discrepancies between analyses for zinc, strontium, manganese, and iron may be attributed to sampling inhomogeneity problems. Mossbauer spectroscopy showed that approximately 44 percent of the pyritic sulfur was lost through weathering in the first year after preparation of the interlaboratory sample. Szomolnokite and possibly coquimbite and jarosite were also identified. Scanning electron microscopy studies indicated ubiquitous pyrite framboids and, less commonly, euhedral crystals, skeletal grains, irregularly shaped particles, and vein fillings. Minor accessory minerals such as rare-earth phosphates and possibly silicates, zircon, barium sulfate, titanium oxide, and sphalerite were also found. The textural evidence indicates that the minerals in the banded material are detrital whereas the minerals occurring as vein and pore fillings are authigenic. Magnetic measurements indicate that coal crushed in a steel pulverizer is contaminated by small quantities of abrasion fragments from the crusher, which seriously affect the measured magnetic properties of the coal.

  5. Inter-laboratory consistency and variability in the buccal micronucleus cytome assay depends on biomarker scored and laboratory experience: results from the HUMNxl international inter-laboratory scoring exercise.

    PubMed

    Bolognesi, Claudia; Knasmueller, Siegfried; Nersesyan, Armen; Roggieri, Paola; Ceppi, Marcello; Bruzzone, Marco; Blaszczyk, Ewa; Mielzynska-Svach, Danuta; Milic, Mirta; Bonassi, Stefano; Benedetti, Danieli; Da Silva, Juliana; Toledo, Raphael; Salvadori, Daisy Maria Fávero; Groot de Restrepo, Helena; Filipic, Metka; Hercog, Klara; Aktas, Ayça; Burgaz, Sema; Kundi, Michael; Grummt, Tamara; Thomas, Philip; Hor, Maryam; Escudero-Fung, Maria; Holland, Nina; Fenech, Michael

    2017-03-01

    The buccal micronucleus cytome (BMNcyt) assay in uncultured exfoliated epithelial cells from oral mucosa is widely applied in biomonitoring human exposures to genotoxic agents and is also proposed as a suitable test for prescreening and follow-up of precancerous oral lesions. The main limitation of the assay is the large variability observed in the baseline values of micronuclei (MNi) and other nuclear anomalies mainly related to different scoring criteria. The aim of this international collaborative study, involving laboratories with different level of experience, was to evaluate the inter- and intra-laboratory variations in the BMNcyt parameters, using recently implemented guidelines, in scoring cells from the same pooled samples obtained from healthy subjects (control group) and from cancer patients undergoing radiotherapy (treated group). The results indicate that all laboratories correctly discriminated samples from the two groups by a significant increase of micronucleus (MN) and nuclear bud (NBUD) frequencies and differentiated binucleated (BN) cells, associated with the exposure to ionizing radiation. The experience of the laboratories was shown to play an important role in the identification of the different cell types and nuclear anomalies. MN frequency in differentiated mononucleated (MONO) and BN cells showed the greatest consistency among the laboratories and low variability was also detected in the frequencies of MONO and BN cells. A larger variability was observed in classifying the different cell types, indicating the subjectivity in the interpretation of some of the scoring criteria while reproducibility of the results between scoring sessions was very good. An inter-laboratory calibration exercise is strongly recommended before starting studies with BMNcyt assay involving multiple research centers. © The Author 2016. Published by Oxford University Press on behalf of the UK Environmental Mutagen Society. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Interlaboratory comparison of reference materials for nitrogen-isotope-ratio measurements

    USGS Publications Warehouse

    Böhlke, John Karl; Coplen, Tyler B.

    1995-01-01

    Aliquots of seven different reference materials were distributed for an interlaboratory comparison of stable nitrogen-isotope-ratio measurements. Results from 15 laboratories were compiled and evaluated selectively to yield provisional values of 515N for each material, i, with respect to atmospheric N2 (o1SN,7air). The 515N values reported by the different laboratories are correlated in such a way that some of the major discrepancies may be removed by normalization (/. e., by altering the length of the ô N scale for each laboratory by an amount defined by local measurements of reference materials with extreme values).

  7. Results of ASTM round robin testing for mode 1 interlaminar fracture toughness of composite materials

    NASA Technical Reports Server (NTRS)

    Obrien, T. Kevin; Martin, Roderick H.

    1992-01-01

    The results are summarized of several interlaboratory 'round robin' test programs for measuring the mode 1 interlaminar fracture toughness of advanced fiber reinforced composite materials. Double Cantilever Beam (DCB) tests were conducted by participants in ASTM committee D30 on High Modulus Fibers and their Composites and by representatives of the European Group on Fracture (EGF) and the Japanese Industrial Standards Group (JIS). DCB tests were performed on three AS4 carbon fiber reinforced composite materials: AS4/3501-6 with a brittle epoxy matrix; AS4/BP907 with a tough epoxy matrix; and AS4/PEEK with a tough thermoplastic matrix. Difficulties encountered in manufacturing panels, as well as conducting the tests are discussed. Critical issues that developed during the course of the testing are highlighted. Results of the round robin testing used to determine the precision of the ASTM DCB test standard are summarized.

  8. Development and validation of an OECD reproductive toxicity test guideline with the pond snail Lymnaea stagnalis (Mollusca, Gastropoda).

    PubMed

    Ducrot, Virginie; Askem, Clare; Azam, Didier; Brettschneider, Denise; Brown, Rebecca; Charles, Sandrine; Coke, Maïra; Collinet, Marc; Delignette-Muller, Marie-Laure; Forfait-Dubuc, Carole; Holbech, Henrik; Hutchinson, Thomas; Jach, Arne; Kinnberg, Karin L; Lacoste, Cédric; Le Page, Gareth; Matthiessen, Peter; Oehlmann, Jörg; Rice, Lynsey; Roberts, Edward; Ruppert, Katharina; Davis, Jessica Elphinstone; Veauvy, Clemence; Weltje, Lennart; Wortham, Ruth; Lagadic, Laurent

    2014-12-01

    The OECD test guideline development program has been extended in 2011 to establish a partial life-cycle protocol for assessing the reproductive toxicity of chemicals to several mollusk species, including the great pond snail Lymnaea stagnalis. In this paper, we summarize the standard draft protocol for a reproduction test with this species, and present inter-comparison results obtained in a 56-day prevalidation ring-test using this protocol. Seven European laboratories performed semi-static tests with cultured snails of the strain Renilys® exposed to nominal concentrations of cadmium chloride (from 53 to 608μgCdL(-1)). Cd concentrations in test solutions were analytically determined to confirm accuracy in the metal exposure concentrations in all laboratories. Physico-chemical and biological validity criteria (namely dissolved oxygen content >60% ASV, water temperature 20±1°C, control snail survival >80% and control snail fecundity >8 egg-masses per snail over the test period) were met in all laboratories which consistently demonstrated the reproductive toxicity of Cd in snails using the proposed draft protocol. Effect concentrations for fecundity after 56days were reproducible between laboratories (68

  9. An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: first round.

    PubMed

    Ehling, G; Hecht, M; Heusener, A; Huesler, J; Gamer, A O; van Loveren, H; Maurer, Th; Riecke, K; Ullmann, L; Ulrich, P; Vandebriel, R; Vohr, H-W

    2005-08-15

    The new OECD guideline 429 (skin sensitization: local lymph node assay) is based upon a protocol, which utilises the incorporation of radioactivity into DNA as a measure for cell proliferation in vivo. The guideline also enables the use of alternative endpoints in order to assess draining lymph node (LN) cell proliferation. Here we describe the first round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in seven laboratories. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products, Swissmedic. Statistical analyses of all data were performed by an independent centre at the University of Bern, Department of Statistics. Ear-draining, LN weight and cell count were used to assess proliferation instead of radioactive labeling of lymph node cells. In addition, the acute inflammatory skin reaction was measured by ear swelling and weight of circular biopsies of the ears to identify skin irritating properties of the test items. Hexylcinnamaldehyde (HCA) and three blinded test items were applied to female, 8--10 weeks old NMRI and BALB/c mice. Results were sent via the independent study coordinator to the statistician. The results of this first round showed that the alternative endpoints of the LLNA are sensitive and robust parameters. The use of ear weights added an important parameter assessing the skin irritation potential, which supports the differentiation of pure irritative from contact allergenic potential. There were absolute no discrepancies between the categorisation of the three test substances A--C determined by each single participating laboratories. The results highlighted also that many parameters do have an impact on the strength of the responses. Therefore, such parameters have to be taken into consideration for the categorisation of compounds due to their relative sensitizing potencies.

  10. Detection of EGFR Variants in Plasma: A Multilaboratory Comparison of the cobas EGFR Mutation Test v2 in Europe.

    PubMed

    Keppens, Cleo; Palma, John F; Das, Partha M; Scudder, Sidney; Wen, Wei; Normanno, Nicola; Van Krieken, J Han; Sacco, Alessandra; Fenizia, Francesca; de Castro, David Gonzalez; Hönigschnabl, Selma; Kern, Izidor; Lopez-Rios, Fernando; Lozano, Maria D; Marchetti, Antonio; Halfon, Philippe; Schuuring, Ed; Setinek, Ulrike; Sorensen, Boe; Taniere, Phillipe; Tiemann, Markus; Vosmikova, Hana; Dequeker, Elisabeth M C

    2018-04-25

    Molecular testing of EGFR is required to predict the response likelihood to targeted therapy in non-small-cell lung cancer. Analysis of circulating tumor DNA in plasma may complement limitations of tumor tissue. This study evaluated the interlaboratory performance and reproducibility of the cobas EGFR Mutation Test v2 to detect EGFR variants in plasma. Fourteen laboratories received two identical panels of 27 single-blinded plasma samples. Samples were wild-type or spiked with plasmid DNA to contain seven common EGFR variants at six predefined concentrations from 50 to 5000 copies per mL. The circulating tumor DNA was extracted by the cobas cfDNA Sample Preparation kit, followed by duplicate analysis with the EGFRv2 kit (Roche Molecular Systems, Pleasanton, CA). Lowest sensitivities were obtained for the c.2156G>C p.(Gly719Ala) and c.2573T>G p.(Leu858Arg) variants for the lowest target copies. For all other variants, sensitivities varied between 96.3% and 100.0%. Specificities were all 98.8% to 100.0%. Coefficients of variation indicated good intra and interlaboratory repeatability and reproducibility, but increased for decreasing concentrations. Prediction models revealed a significant correlation for all variants between the pre-defined copy number and the observed semiquantitative index values which reflects the samples' plasma mutation load. This study demonstrates an overall robust performance of the EGFRv2 kit in plasma. Prediction models may be applied to estimate the plasma mutation load for diagnostic or research purposes. Copyright © 2018 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  11. The Italian external quality assessment for RAS testing in colorectal carcinoma identifies methods-related inter-laboratory differences.

    PubMed

    Normanno, Nicola; Pinto, Carmine; Castiglione, Francesca; Fenizia, Francesca; Barberis, Massimo; Marchetti, Antonio; Fontanini, Gabriella; De Rosa, Gaetano; Taddei, Gian Luigi

    2015-09-03

    In 2014 the European Medicines Agency included exon 2, 3 and 4 KRAS and NRAS testing for the selection of metastatic colorectal cancer (mCRC) patients eligible for the therapy with anti-EGFR monoclonal antibodies. The Italian Association of Medical Oncology (AIOM) and the Italian Society of Pathology and Cytology (SIAPEC) organized an external quality assessment (EQA) scheme for CRC to evaluate inter-laboratory consistency and to ensure standardization of the results in the transition from KRAS to all-RAS testing. Ten formalin fixed paraffin embedded specimens including KRAS/NRAS (exons 2, 3, 4) and BRAF (codon 600) mutations were validated by three referral laboratories and sent to 88 participant centers. Molecular pathology sample reports were also requested to each laboratory. A board of assessors from AIOM and SIAPEC evaluated the results according to a predefined scoring system. The scheme was composed of two rounds. In the first round 36% of the 88 participants failed, with 23 centers having at least one false positive or false negative while 9 centers did not meet the deadline. The genotyping error rate was higher when Sanger sequencing was employed for testing as compared with pyrosequencing (3 vs 1.3%; p = 0.01; Pearson Chi Square test). In the second round, the laboratories improved their performance, with 23/32 laboratories passing the round. Overall, 79/88 participants passed the RAS EQA scheme. Standardized Human Genome Variation Society nomenclature was incorrectly used to describe the mutations identified and relevant variations were noticed in the genotype specification. The results of the Italian RAS EQA scheme indicate that the mutational analyses are performed with good quality in many Italian centers, although significant differences in the methods used were highlighted. The relatively high number of centers failing the first round underlines the fundamental role in continued education covered by EQA schemes.

  12. Multicenter Comparative Evaluation of Six Commercial Systems and the National Committee for Clinical Laboratory Standards M27-A Broth Microdilution Method for Fluconazole Susceptibility Testing of Candida Species

    PubMed Central

    Morace, G.; Amato, G.; Bistoni, F.; Fadda, G.; Marone, P.; Montagna, M. T.; Oliveri, S.; Polonelli, L.; Rigoli, R.; Mancuso, I.; La Face, S.; Masucci, L.; Romano, L.; Napoli, C.; Tatò, D.; Buscema, M. G.; Belli, C. M. C.; Piccirillo, M. M.; Conti, S.; Covan, S.; Fanti, F.; Cavanna, C.; D'Alò, F.; Pitzurra, L.

    2002-01-01

    Fluconazole susceptibility among 800 clinical Candida isolates (60% C. albicans) and two control strains (C. krusei ATCC 6258 and C. parapsilosis ATCC 22019) was tested with the NCCLS M27-A method (gold standard) and six commercial products (Candifast, disk, Etest, Fungitest, Integral System Yeasts, and Sensititre YeastOne). Results were classified as susceptible, susceptible-dose dependent, or resistant using M27-A breakpoints or, for Fungitest, Integral System Yeasts, and Candifast, as susceptible, intermediate, or resistant, according to the manufacturers' instructions. Concordance with NCCLS M27-A results was analyzed with the χ2 test. Intra- and interlaboratory reproducibility was also evaluated. NCCLS M27-A (90.1%), Etest (93.1%), Sensititre YeastOne (93.1%), disk (96.7%), Fungitest (92.6%), Integral System Yeasts (40.6%), and Candifast (6.0%) classified the indicated percentages of C. albicans isolates as susceptible. Among non-C. albicans strains, the percentages of susceptible isolates were as follows: NCCLS M27-A, 74.0%; Etest, 83.8%; Sensititre YeastOne, 64.1%; disk, 60.6%; Fungitest, 76.6%; Integral System Yeasts, 28.3%; and Candifast, 27.4%. All methods except Candifast and Integral System Yeasts showed good agreement with NCCLS M27-A results for both C albicans and non-C. albicans isolates. Intralaboratory reproducibility was excellent for NCCLS M27-A, Etest, Sensititre YeastOne, disk, and Fungitest (88 to 91%). Similar results emerged from the interlaboratory reproducibility evaluation. Our findings indicate that some commercial methods can be useful for fluconazole susceptibility testing of clinical Candida isolates. Those characterized by a lack of medium standardization and/or objective interpretative criteria should be avoided. Particular caution is necessary when testing is being done for clinical and epidemiological purposes. PMID:12149358

  13. A Follow-Up of the Multicenter Collaborative Study on HIV-1 Drug Resistance and Tropism Testing Using 454 Ultra Deep Pyrosequencing

    PubMed Central

    St. John, Elizabeth P.; Simen, Birgitte B.; Turenchalk, Gregory S.; Braverman, Michael S.; Abbate, Isabella; Aerssens, Jeroen; Bouchez, Olivier; Gabriel, Christian; Izopet, Jacques; Meixenberger, Karolin; Di Giallonardo, Francesca; Schlapbach, Ralph; Paredes, Roger; Sakwa, James; Schmitz-Agheguian, Gudrun G.; Thielen, Alexander; Victor, Martin

    2016-01-01

    Background Ultra deep sequencing is of increasing use not only in research but also in diagnostics. For implementation of ultra deep sequencing assays in clinical laboratories for routine diagnostics, intra- and inter-laboratory testing are of the utmost importance. Methods A multicenter study was conducted to validate an updated assay design for 454 Life Sciences’ GS FLX Titanium system targeting protease/reverse transcriptase (RTP) and env (V3) regions to identify HIV-1 drug-resistance mutations and determine co-receptor use with high sensitivity. The study included 30 HIV-1 subtype B and 6 subtype non-B samples with viral titers (VT) of 3,940–447,400 copies/mL, two dilution series (52,129–1,340 and 25,130–734 copies/mL), and triplicate samples. Amplicons spanning PR codons 10–99, RT codons 1–251 and the entire V3 region were generated using barcoded primers. Analysis was performed using the GS Amplicon Variant Analyzer and geno2pheno for tropism. For comparison, population sequencing was performed using the ViroSeq HIV-1 genotyping system. Results The median sequencing depth across the 11 sites was 1,829 reads per position for RTP (IQR 592–3,488) and 2,410 for V3 (IQR 786–3,695). 10 preselected drug resistant variants were measured across sites and showed high inter-laboratory correlation across all sites with data (P<0.001). The triplicate samples of a plasmid mixture confirmed the high inter-laboratory consistency (mean% ± stdev: 4.6 ±0.5, 4.8 ±0.4, 4.9 ±0.3) and revealed good intra-laboratory consistency (mean% range ± stdev range: 4.2–5.2 ± 0.04–0.65). In the two dilutions series, no variants >20% were missed, variants 2–10% were detected at most sites (even at low VT), and variants 1–2% were detected by some sites. All mutations detected by population sequencing were also detected by UDS. Conclusions This assay design results in an accurate and reproducible approach to analyze HIV-1 mutant spectra, even at variant frequencies well below those routinely detectable by population sequencing. PMID:26756901

  14. United Nations Environment Programme Capacity Building Pilot Project--training and interlaboratory study on persistent organic pollutant analysis under the Stockholm Convention.

    PubMed

    de Boer, J; Leslie, H; van Leeuwen, S P J; Wegener, J-W; van Bavel, B; Lindström, G; Lahoutifard, N; Fiedler, H

    2008-06-09

    Within the framework of a United Nations Environment Programme (UNEP) Capacity Building Project for training of laboratory staff in developing countries on persistent organic pollutant (POP) analysis, an interlaboratory study was organised following an initial evaluation of the performance of laboratories (reality check) and a series of training sessions. The target compounds were polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP). Seven laboratories from five countries (Ecuador, Uruguay, Kenya, Moldova, and Fiji) participated. Most of the laboratories had no experience in determining PCBs. Although chromatograms improved considerably after the training and installation of new gas chromatographic (GC) columns at participating laboratories, the level of performance in the interlaboratory study was essentially on par with the moderate performance level achieved by European POP laboratories in the 1980s. Only some individual results were within +/-20% of the target values. The relative standard deviations (R.S.D.s) in POP concentrations determined by laboratories in a sediment sample were >200% in a number of cases. The results for a certified herring sample were better with at least some R.S.D. values below 50% and most below 100%. Clean up was as one of the main sources of error. After inspection it was ascertained that training of laboratory staff and investments in simple consumables such as glassware and GC columns would help to improve the quality of the analysis more than major investments in expensive instrumentation. Creating an effective network of POP laboratories at different continents together with a series of interlaboratory studies and workshops is suggested to improve the measurements of POPs in these countries.

  15. Top down arsenic uncertainty measurement in water and sediments from Guarapiranga dam (Brazil)

    NASA Astrophysics Data System (ADS)

    Faustino, M. G.; Lange, C. N.; Monteiro, L. R.; Furusawa, H. A.; Marques, J. R.; Stellato, T. B.; Soares, S. M. V.; da Silva, T. B. S. C.; da Silva, D. B.; Cotrim, M. E. B.; Pires, M. A. F.

    2018-03-01

    Total arsenic measurements assessment regarding legal threshold demands more than average and standard deviation approach. In this way, analytical measurement uncertainty evaluation was conducted in order to comply with legal requirements and to allow the balance of arsenic in both water and sediment compartments. A top-down approach for measurement uncertainties was applied to evaluate arsenic concentrations in water and sediments from Guarapiranga dam (São Paulo, Brazil). Laboratory quality control and arsenic interlaboratory tests data were used in this approach to estimate the uncertainties associated with the methodology.

  16. National and international veterinary reference laboratories for infectious diseases.

    PubMed

    Edwards, S; Alexander, D

    1998-08-01

    Reference laboratories play an increasingly important role in the harmonisation of laboratory diagnostic tests and the standardisation of veterinary vaccines. This is particularly important in building confidence between international trading partners. The authors review aspects of the organisation, designation and support of reference laboratories for infectious diseases of animals and discuss the principal activities which such laboratories would normally perform. These activities include advice and consultancy, publications and communication, training, research, disease surveillance, maintenance of culture collections, evaluation of reference methods, preparation of reference materials and organisation of inter-laboratory comparisons.

  17. Receptor binding assay for paralytic shellfish poisoning toxins: optimization and interlaboratory comparison.

    PubMed

    Ruberu, Shryamalie R; Liu, Yun-Gang; Wong, Carolyn T; Perera, S Kusum; Langlois, Gregg W; Doucette, Gregory J; Powell, Christine L

    2003-01-01

    A receptor binding assay (RBA) for detection of paralytic shellfish poisoning (PSP) toxins was formatted for use in a high throughput detection system using microplate scintillation counting. The RBA technology was transferred from the National Ocean Service, which uses a Wallac TriLux 1450 MicroBeta microplate scintillation counter, to the California Department of Health Services, which uses a Packard TopCount scintillation counter. Due to differences in the detector arrangement between these 2 counters, markedly different counting efficiencies were exhibited, requiring optimization of the RBA protocol for the TopCount instrument. Precision, accuracy, and sensitivity [limit of detection = 0.2 microg saxitoxin (STX) equiv/100 g shellfish tissue] of the modified protocol were equivalent to those of the original protocol. The RBA robustness and adaptability were demonstrated by an interlaboratory study, in which STX concentrations in shellfish generated by the TopCount were consistent with MicroBeta-derived values. Comparison of STX reference standards obtained from the U.S. Food and Drug Administration and the National Research Council, Canada, showed no observable differences. This study confirms the RBA's value as a rapid, high throughput screen prior to testing by the conventional mouse bioassay (MBA) and its suitability for providing an early warning of increasing PSP toxicity when toxin levels are below the MBA limit of detection.

  18. Validation of a quantitative cerebrospinal fluid alpha-synuclein assay in a European-wide interlaboratory study.

    PubMed

    Kruse, Niels; Persson, Staffan; Alcolea, Daniel; Bahl, Justyna M C; Baldeiras, Ines; Capello, Elisabetta; Chiasserini, Davide; Bocchio Chiavetto, Luisella; Emersic, Andreja; Engelborghs, Sebastiaan; Eren, Erden; Fladby, Tormod; Frisoni, Giovanni; García-Ayllón, María-Salud; Genc, Sermin; Gkatzima, Olymbia; Heegaard, Niels H H; Janeiro, André M; Kováčech, Branislav; Kuiperij, H Bea; Leitão, Maria J; Lleó, Alberto; Martins, Madalena; Matos, Mafalda; Mollergard, Hanne M; Nobili, Flavio; Öhrfelt, Annika; Parnetti, Lucilla; de Oliveira, Catarina Resende; Rot, Uros; Sáez-Valero, Javier; Struyfs, Hanne; Tanassi, Julia T; Taylor, Peggy; Tsolaki, Magda; Vanmechelen, Eugeen; Verbeek, Marcel M; Zilka, Norbert; Blennow, Kaj; Zetterberg, Henrik; Mollenhauer, Brit

    2015-09-01

    Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program - Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Inter-laboratory study to characterize the detection of serum antibodies against porcine epidemic diarrhoea virus.

    PubMed

    Strandbygaard, Bertel; Lavazza, Antonio; Lelli, Davide; Blanchard, Yannick; Grasland, Béatrice; Poder, Sophie Le; Rose, Nicolas; Steinbach, Falko; van der Poel, Wim H M; Widén, Frederik; Belsham, Graham J; Bøtner, Anette

    2016-12-25

    Porcine epidemic diarrhea virus (PEDV) has caused extensive economic losses to pig producers in many countries. It was recently introduced, for the first time, into North America and outbreaks have occurred again in multiple countries within Europe as well. To assess the properties of various diagnostic assays for the detection of PEDV infection, multiple panels of porcine sera have been shared and tested for the presence of antibodies against PEDV in an inter-laboratory ring trial. Different laboratories have used a variety of "in house" ELISAs and also one commercial assay. The sensitivity and specificity of each assay has been estimated using a Bayesian analysis applied to the ring trial results obtained with the different assays in the absence of a gold standard. Although different characteristics were found, it can be concluded that each of the assays used can detect infection of pigs at a herd level by either the early European strains of PEDV or the recently circulating strains (INDEL and non-INDEL). However, not all the assays seem suitable for demonstrating freedom from disease in a country. The results from individual animals, especially when the infection has occurred within an experimental situation, show more variation. Copyright © 2016. Published by Elsevier B.V.

  20. Moments of Inertia

    DTIC Science & Technology

    2017-08-03

    Army Test and Evaluation Command 2202 Aberdeen Boulevard Aberdeen Proving Ground, MD 21005-5001 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR...properties that provide information on a vehicle’s mass distribution. The properties impact vehicle design and safety and are primary inputs to vehicle...also useful in the design and construction of vehicle safety outriggers needed during the conduct of dynamic handling tests. This document

  1. Ultra-trace analysis of 41Ca in urine by accelerator mass spectrometry: an inter-laboratory comparison

    PubMed Central

    Jackson, George S.; Hillegonds, Darren J.; Muzikar, Paul; Goehring, Brent

    2013-01-01

    A 41Ca interlaboratory comparison between Lawrence Livermore National Laboratory (LLNL) and the Purdue Rare Isotope Laboratory (PRIME Lab) has been completed. Analysis of the ratios assayed by accelerator mass spectrometry (AMS) shows that there is no statistically significant difference in the ratios. Further, Bayesian analysis shows that the uncertainties reported by both facilities are correct with the possibility of a slight under-estimation by one laboratory. Finally, the chemistry procedures used by the two facilities to produce CaF2 for the cesium sputter ion source are robust and don't yield any significant differences in the final result. PMID:24179312

  2. Results of an interlaboratory method performance study for the size determination and quantification of silver nanoparticles in chicken meat by single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS).

    PubMed

    Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J

    2017-08-01

    Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.

  3. Rapid Analysis of Carbohydrates in Bioprocess Samples: An Evaluation of the CarboPac SA10 for HPAE-PAD Analysis by Interlaboratory Comparison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sevcik, R. S.; Hyman, D. A.; Basumallich, L.

    2013-01-01

    A technique for carbohydrate analysis for bioprocess samples has been developed, providing reduced analysis time compared to current practice in the biofuels R&D community. The Thermofisher CarboPac SA10 anion-exchange column enables isocratic separation of monosaccharides, sucrose and cellobiose in approximately 7 minutes. Additionally, use of a low-volume (0.2 mL) injection valve in combination with a high-volume detection cell minimizes the extent of sample dilution required to bring sugar concentrations into the linear range of the pulsed amperometric detector (PAD). Three laboratories, representing academia, industry, and government, participated in an interlaboratory study which analyzed twenty-one opportunistic samples representing biomass pretreatment, enzymaticmore » saccharification, and fermentation samples. The technique's robustness, linearity, and interlaboratory reproducibility were evaluated and showed excellent-to-acceptable characteristics. Additionally, quantitation by the CarboPac SA10/PAD was compared with the current practice method utilizing a HPX-87P/RID. While these two methods showed good agreement a statistical comparison found significant quantitation difference between them, highlighting the difference between selective and universal detection modes.« less

  4. Qualitative PCR method for Roundup Ready soybean: interlaboratory study.

    PubMed

    Kodama, Takashi; Kasahara, Masaki; Minegishi, Yasutaka; Futo, Satoshi; Sawada, Chihiro; Watai, Masatoshi; Akiyama, Hiroshi; Teshima, Reiko; Kurosawa, Yasunori; Furui, Satoshi; Hino, Akihiro; Kitta, Kazumi

    2011-01-01

    Quantitative and qualitative methods based on PCR have been developed for genetically modified organisms (GMO). Interlaboratory studies were previously conducted for GMO quantitative methods; in this study, an interlaboratory study was conducted for a qualitative method for a GM soybean, Roundup Ready soy (RR soy), with primer pairs designed for the quantitative method of RR soy studied previously. Fourteen laboratories in Japan participated. Each participant extracted DNA from 1.0 g each of the soy samples containing 0, 0.05, and 0.10% of RR soy, and performed PCR with primer pairs for an internal control gene (Le1) and RR soy followed by agarose gel electrophoresis. The PCR product amplified in this PCR system for Le1 was detected from all samples. The sensitivity, specificity, and false-negative and false-positive rates of the method were obtained from the results of RR soy detection. False-negative rates at the level of 0.05 and 0.10% of the RR soy samples were 6.0 and 2.3%, respectively, revealing that the LOD of the method was somewhat below 0.10%. The current study demonstrated that the qualitative method would be practical for monitoring the labeling system of GM soy in kernel lots.

  5. The influence of industry sponsorship on the reporting of subgroup analyses within phase III randomised controlled trials in gastrointestinal oncology.

    PubMed

    Barton, Sarah; Peckitt, Clare; Sclafani, Francesco; Cunningham, David; Chau, Ian

    2015-12-01

    Correct interpretation of subgroup analyses (SGA) is important as it influences selection of therapeutic interventions for patient subsets. The primary aim of our study was to compare reporting of SGA between industry and non-industry sponsored trials. We performed a systematic literature review and extracted data from journal articles (JA) and conference abstracts (CA) published over a decade reporting SGA results of phase III randomised controlled gastrointestinal (GI) oncology trials with patient participants of ≥150. In JA, SGA was reported in 100/145 (69%) trials: 41/54 industry sponsored (76%; 95% confidence interval [CI]: 63-86%) and 59/91 non-industry sponsored (65%; 95% CI: 55-74%) trials (p = 0.16). In CA, SGA was reported in 86/204 (42%) trials: 43/83 industry sponsored (52%; 95% CI: 41-62%) and 43/121 non-industry sponsored (36%; 95% CI: 28-44%) trials (p = 0.02). Number of SGA performed per trial was significantly larger for industry compared to non-industry sponsored trials in both JA (median 6 versus 2, p = 0.003) and CA (median 1 versus 0, p = 0.023). Claims of subgroup effect were made in 52% of trials in JA and 50% in CA, with significant test of interaction evident in only 25% of JA and 16% of CA, with no difference between industry and non-industry trials. Industry sponsored trials with a significant primary end-point reported more SGA (p < 0.001 JA; p = 0.046 CA). Industry sponsored trials reported more SGA. Claimed subgroup effects were often not accompanied by significant interaction test; thus circumspection should be adopted when using SGA to deviate from standard therapeutic decision-making in GI oncology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Deterrence in the Human Domain: A COIN Framework to Deterring Unconventional Warfare in Shaping Operations

    DTIC Science & Technology

    2017-05-25

    Wilkinson US Army School of Advanced Military Studies United States Army Command and General Staff College Fort Leavenworth, Kansas 2017 Approved for...SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) Advanced Military Studies Program 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S...adversary’s unconventional threat. To test this framework, this monograph analyzes a case study of how Russia will likely use unconventional forces and

  7. Evaluation of Gentian cystatin C reagent on Abbott Ci8200 and calculation of glomerular filtration rate expressed in mL/min/1.73 m(2) from the cystatin C values in mg/L.

    PubMed

    Flodin, M; Jonsson, A-S; Hansson, L-O; Danielsson, L-A; Larsson, A

    2007-01-01

    Estimation of the glomerular filtration rate (GFR) is essential when evaluating patients with kidney disease and treating patients with drugs eliminated from the circulation by the kidneys. Cystatin C has been shown in several studies to be superior to creatinine in the estimation of GFR. At our hospitals, there is an increasing demand for cystatin C and at present we perform approximately 1500 cystatin C analyses a month. We thus need the assay available 24 h/day and to have it on our routine chemistry instrument to minimize handling time per test and time to reported test results. We have evaluated a new cystatin C immunoassay from Gentian (Gentian, Moss, Norway) on Architect ci8200 (Abbott Laboratories, Abbott Park, Ill., USA). A prerequisite at our hospital is that cystatin C results are reported as a calculated GFR in mL/min/1.73 m(2), so we also made a comparison with iohexol clearance. The Gentian cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, Ill., USA) and good inter-laboratory concordance. The assay has very low total imprecision, good linearity and strong correlation with iohexol clearance (R (2) = 0.956). The equation for the correlation curve is: y = 79.901x(-1.4389). There was low inter-laboratory variation between the three laboratories involved in the cystatin C evaluation, and thus all three laboratories can use the same equation for calculating the estimated GFR.

  8. Determination of Trimethoprim-Sulfamethoxazole Resistance in Streptococcus pneumoniae by Using the E Test with Mueller-Hinton Agar Supplemented with Sheep or Horse Blood May Be Unreliable

    PubMed Central

    Lovgren, M.; Dell’Acqua, L.; Palacio, R.; Echániz-Aviles, G.; Soto-Noguerón, A.; Castañeda, E.; Agudelo, C. I.; Heitmann, I.; Brandileone, M. C.; Zanella, R. C.; Rossi, A.; Pace, J.; Talbot, J. A.

    1999-01-01

    An international, multicenter study compared trimethoprim-sulfamethoxazole MICs for 743 Streptococcus pneumoniae isolates (107 to 244 isolates per country) by E test, using Mueller-Hinton agar supplemented with 5% defibrinated horse blood or 5% defibrinated sheep blood, with MICs determined by the National Committee for Clinical Laboratory Standards broth microdilution reference method. Agreement within 1 log2 dilution and minor error rates were 69.3 and 15.5%, respectively, on sheep blood-supplemented agar and 76.9 and 13.6%, respectively, with horse blood as the supplement. Significant interlaboratory variability was observed. E test may not be a reliable method for determining the resistance of pneumococci to trimethoprim-sulfamethoxazole. PMID:9854095

  9. The Use of Thermal Spraying to Enhance the Bonding Characteristics of a Urethane Coated Propeller

    DTIC Science & Technology

    1999-05-03

    NAME(S) AND ADDRESS( ES ) 8. PERFORMING ORGANIZATION REPORT NUMBER U.S. Naval Academy USNA Trident Scholar project report Annapolis, MD no. 265 (1999...9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSORING/MONITORING AGENCY REPORT NUMBER 11. SUPPLEMENTARY NOTES Accepted by the U.S...TEST: A 90-degree Peel Test was used to examine the bond strength of the specimens. A SATEC tensile test machine was used with a 2000 lb. load cell

  10. Access : Brokering Paratransit Services to the Elderly and Handicapped in Allegheny County, PA

    DOT National Transportation Integrated Search

    1984-12-01

    This report describes and evaluates the elderly and handicapped brokerage project sponsored by UMTA's Service and Methods Demonstration Program. The demonstration, sponsored locally by the Port Authority of Allegheny County, tests the concept of tran...

  11. Method and platform standardization in MRM-based quantitative plasma proteomics.

    PubMed

    Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H

    2013-12-16

    There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.

  12. Enabling reliability assessments of pre-commercial perovskite photovoltaics with lessons learned from industrial standards

    NASA Astrophysics Data System (ADS)

    Snaith, Henry J.; Hacke, Peter

    2018-06-01

    Photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.

  13. Hull Material Evaluation for Navy 44 Sail Training Vessel

    DTIC Science & Technology

    2001-01-01

    NAME(S) AND ADDRESS( ES ) United States Naval Academy,Annapolis,MD,21402 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S...AND ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for...compared in a SATEC UD50. In the flex test, a 1” x16” fiberglass coupon was placed on 1” diameter supports spaced fourteen inches apart with the tensile

  14. Critique of Test Methodologies for Biological Agent Detection and Identification Systems for Military and First Responders

    DTIC Science & Technology

    2002-01-01

    PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND ADDRESS(ES) New...Horizons Diagnostics, Columbia, MD 21045 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR...MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution

  15. Composite Failure Analysis Handbook. Volume 2. Technical Handbook/ Part 2. Atlas of Fractographs

    DTIC Science & Technology

    1992-02-01

    ADDRESS( ES ) 8. PERFORMING ORGANIZATION Northrop Corporation REPORT NUMBER Aircraft Division One Northrop Avenue Hawthorne, California 90250-3277 9...SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSORING/ MONITORING Wright Laboratory (WL/MLSA) AGENCY REPORT NUMBER Materials Directorate...specimens of 0/90 laminates were tested in a Satec 25,000-lb capacity Universal test machine with the crosshead speed set at .001 in/min. Deflection

  16. A comparison of the MeltPro® HPV Test with the Cobas® HPV Test for detecting and genotyping 14 high-risk human papillomavirus types.

    PubMed

    Tang, Zhiteng; Xu, Ye; Song, Najie; Zou, Dongqing; Liao, Yiqun; Li, Qingge; Pan, Chao

    2018-03-01

    The clinical performance of the newly developed MeltPro ® HPV Test, based on multicolor melting curve analysis, was evaluated and compared with the commercially available Cobas ® HPV Test for detection of HPV and genotyping of HPV-16 and HPV-18. A total of 1647 cervical samples were analyzed with both tests. The agreement values were 96.2% for HPV detection, 99.6% for HPV-16 identification, and 99.7% for HPV-18 identification. All genotyping results from MeltPro ® HPV Test showed that HPV-52, HPV-58, and HPV-16 were the most common types in this study. Intra-laboratory reproducibility studies showed 97.8% agreement while inter-laboratory reproducibility studies showed 96.9% agreement for the MeltPro ® HPV Test. The MeltPro ® HPV Test and Cobas ® HPV Test are highly correlative and are useful for monitoring HPV infection.

  17. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less

  18. Experimental design of an interlaboratory study for trace metal analysis of liquid fluids. [for aerospace vehicles

    NASA Technical Reports Server (NTRS)

    Greenbauer-Seng, L. A.

    1983-01-01

    The accurate determination of trace metals and fuels is an important requirement in much of the research into and development of alternative fuels for aerospace applications. Recognizing the detrimental effects of certain metals on fuel performance and fuel systems at the part per million and in some cases part per billion levels requires improved accuracy in determining these low concentration elements. Accurate analyses are also required to ensure interchangeability of analysis results between vendor, researcher, and end use for purposes of quality control. Previous interlaboratory studies have demonstrated the inability of different laboratories to agree on the results of metal analysis, particularly at low concentration levels, yet typically good precisions are reported within a laboratory. An interlaboratory study was designed to gain statistical information about the sources of variation in the reported concentrations. Five participant laboratories were used on a fee basis and were not informed of the purpose of the analyses. The effects of laboratory, analytical technique, concentration level, and ashing additive were studied in four fuel types for 20 elements of interest. The prescribed sample preparation schemes (variations of dry ashing) were used by all of the laboratories. The analytical data were statistically evaluated using a computer program for the analysis of variance technique.

  19. Inter-laboratory comparison of X-ray fluorescence analyses of eruptive products of El Chichón Volcano, Chiapas, Mexico

    USGS Publications Warehouse

    Tilling, Robert I.; Bornhorst, Theodore J.; Taggart, Joseph E.; Rose, William I.; McGee, James J.

    1987-01-01

    An inter-laboratory comparison has been made of X-ray fluorescence analyses of 10 samples of lava and pumices from El Chichón Volcano, Chiapas, Mexico. Some determinations of major-element constituents agree within analytical uncertainty, whereas others exchibit significant bias. Analyses carried out at the Michigan Technological University (MTU) laboratory are systematically lower in MgO (26–48%), Fetotal(5–18%), CaO (4–15%) and higher in K2O (0–15%) than analyses made at the U.S. Geological Survey (USGS) Denver laboratory. These differences are ascribed in part to a complex combination of calibration assumptionsand mineralogical and particle-size effects inherent in the use of pressed rock-powder pellets in the analytical procedure of the MTU laboratory. Other, but as yet unknown, differences in sample preparation and/or analytical technique may also be important; effects related to natural sample inhomogeneityare believed to be insignificant. The inter-laboratory differences in the analytical data complicated accurate assessment of whether El Chichón magmas have changed composition during the past 300 000 a. Knowledge of such change is needed for understanding petrogenetic history and for such related studies as evaluation of volcanic hazards.

  20. Intranasal Rapamycin Rescues Mice from Staphylococcal Enterotoxin B-Induced Shock

    DTIC Science & Technology

    2012-09-18

    PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Medical Research Institute of...Infectious Diseases,Fort Detrick,MD,21702 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR...Student’s t-test. Statistical comparisons of survival data were performed by Fisher’s exact test with Stata software (Stata Corp., College Station, TX

  1. An Update to the EARTHTIME Argon Intercalibration Pipette System (APIS): Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Deino, A. L.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.

    2015-12-01

    Background: An initial 40Ar/39Ar inter-calibration experiment, using two of the most commonly used 40Ar/39Ar mineral standards, Fish Canyon (FC, ~28.2 Ma) and Alder Creek (AC, ~1.2 Ma) sanidines, revealed significant inter-laboratory inconsistencies. The reported ages for the AC sanidines range from 1.173 to 1.200 Ma (FC 28.02) (±~2%), ~4 times greater than the reported precisions. These experiments have motivated the 40Ar/39Ar community to reevaluate procedures and subsequent informal lab intercalibrations experiments are in better agreement, but discrepancies remain that need to be addressed. Experiment: In an effort to isolate the causes of these inconsistencies, an Argon Intercalibration Pipette System (APIS) was designed and constructed. The APIS system consists of three gas canisters; one containing atmospheric Ar and the other two canisters contain 40Ar/39Ar ratios that represent FC and AC. The volumes of the pipettes, bulbs and manifold are determined to within 0.4% and both systems were initially filled to the same pressure with Ar standard gases. Each canister has 4x10-10 moles of 40Ar, is equipped with a 0.1, 0.2 and 0.4 cc pipettes and can deliver increments from 0.1-0.7 cc. APIS-1 was designated as the traveling unit that is brought to participating labs, APIS-2 is the reserve/master standard. Early Results and Impressions: APIS-1 has been to four labs (Rutgers, LDEO, New Mexico Tech, and BGC) and is heading to ASU. Early APIS experimental data indicate that the inter-laboratory 40Ar/39Ar age results can meet or exceed the EARTHTIME goal of ±1‰ precision. The inter-laboratory comparisons are ongoing, and will include additional laboratories of opportunity. Lastly, the development of additional mineral standards that "fill in" the age gaps between the existing mineral standards would significantly improve attempting to achieve interlaboratory agreement at the ±1‰ level

  2. Extension of the validation of AOAC Official Method 2005.06 for dc-GTX2,3: interlaboratory study.

    PubMed

    Ben-Gigirey, Begoña; Rodríguez-Velasco, María L; Gago-Martínez, Ana

    2012-01-01

    AOAC Official Method(SM) 2005.06 for the determination of saxitoxin (STX)-group toxins in shellfish by LC with fluorescence detection with precolumn oxidation was previously validated and adopted First Action following a collaborative study. However, the method was not validated for all key STX-group toxins, and procedures to quantify some of them were not provided. With more STX-group toxin standards commercially available and modifications to procedures, it was possible to overcome some of these difficulties. The European Union Reference Laboratory for Marine Biotoxins conducted an interlaboratory exercise to extend AOAC Official Method 2005.06 validation for dc-GTX2,3 and to compile precision data for several STX-group toxins. This paper reports the study design and the results obtained. The performance characteristics for dc-GTX2,3 (intralaboratory and interlaboratory precision, recovery, and theoretical quantification limit) were evaluated. The mean recoveries obtained for dc-GTX2,3 were, in general, low (53.1-58.6%). The RSD for reproducibility (RSD(r)%) for dc-GTX2,3 in all samples ranged from 28.2 to 45.7%, and HorRat values ranged from 1.5 to 2.8. The article also describes a hydrolysis protocol to convert GTX6 to NEO, which has been proven to be useful for the quantification of GTX6 while the GTX6 standard is not available. The performance of the participant laboratories in the application of this method was compared with that obtained from the original collaborative study of the method. Intralaboratory and interlaboratory precision data for several STX-group toxins, including dc-NEO and GTX6, are reported here. This study can be useful for those laboratories determining STX-group toxins to fully implement AOAC Official Method 2005.06 for official paralytic shellfish poisoning control. However the overall quantitative performance obtained with the method was poor for certain toxins.

  3. Influence of precracked specimen configuration and starting stress intensity on the stress corrosion cracking of 4340 steel

    NASA Technical Reports Server (NTRS)

    Lisagor, W. B.

    1984-01-01

    Since the pioneer work of Brown (1966), precracked specimens and related fracture mechanics analyses have been extensively used to study stress corrosion cracking. Certain questions arose in connection with initial attempts to prepare standardized recommended practices by ASTM Committee G-1 on Corrosion of Metals. These questions were related to adequacy of test control as it pertains to acceptable limits of variability, and to validity of expressions for stress intensity and crack-surface displacements for both specimen configurations. An interlaboratory test program, was, therefore, planned with the objective to examine the validity of KIscc testing for selected specimen configurations, materials,and environmental systems. The results reported in the present paper include details of a single laboratory test program. The program was conducted to determine if the threshold value of stress intensity for onset and arrest of stress corrosion cracking was independent for the two specimen configurations examined.

  4. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  5. Interlaboratory study for the assessment of potential irritative properties of hygiene products on the hamster cheek pouch.

    PubMed

    Bourrinet, P; Conduzorgues, J P; Dutertre, H; Macabies, J; Masson, P; Maurin, J; Mercier, O

    1995-02-01

    An interlaboratory study was carried out to determine the feasibility and reliability of a method using the hamster cheek pouch as a model for assessing the potential irritative properties of substances intended to be applied to the lips or other mucous membranes. The test substances were applied once daily to both pouches for 14 consecutive days. Local and general tolerances were appraised throughout the study. At the end of the study, histologic examination of the pouches and the main organs was performed. Results of the feasibility study, conducted on various types of commercial products, indicated that this model is suitable for preparations of various consistence and composition. Results of the reliability study, carried out on gel-type preparations containing various concentrations of a known irritant, sodium lauryl sulfate, indicated that the method elicits a dose-dependent reaction for this compound. This hamster cheek pouch method was reproducible for the various parameters under consideration: local tolerance, general tolerance, histologic examination. For all products, results were in good agreement among the various laboratories participating in the study. The French regulatory authorities of the Fraud Repression Department have accepted it as an official method for the evaluation of the potential irritative properties of cosmetics and hygiene products intended to be applied to the lips or other mucous membranes.

  6. Interlaboratory study of free cyanide methods compared to total cyanide measurements and the effect of preservation with sodium hydroxide for secondary- and tertiary-treated waste water samples.

    PubMed

    Stanley, Brett J; Antonio, Karen

    2012-11-01

    Several methods exist for the measurement of cyanide levels in treated wastewater,typically requiring preservation of the sample with sodium hydroxide to minimize loss of hydrogen cyanide gas (HCN). Recent reports have shown that cyanide levels may increase with chlorination or preservation. In this study, three flow injection analysis methods involving colorimetric and amperometric detection were compared within one laboratory, as well as across separate laboratories and equipment. Split wastewater samples from eight facilities and three different sampling periods were tested. An interlaboratory confidence interval of 3.5 ppb was calculated compared with the intralaboratory reporting limit of 2 ppb. The results show that free cyanide measurements are not statistically different than total cyanide levels. An artificial increase in cyanide level is observed with all methods for preserved samples relative to nonpreserved samples, with an average increase of 2.3 ppb. The possible loss of cyanide without preservation is shown to be statistically insignificant if properly stored up to 48 hours. The cyanide increase with preservation is further substantiated with the method of standard additions and is not a matrix interference. The increase appears to be correlated with the amount of cyanide observed without preservation, which appears to be greater in those facilities that disinfect their wastewater with chlorine, followed by dechlorination with sodium bisulfite.

  7. Experience in managing a large-scale rescreening of Papanicolaou smears and the pros and cons of measuring proficiency with visual and written examinations.

    PubMed

    Rube, I F

    1989-01-01

    Experiences in a large-scale interlaboratory rescreening of Papanicolaou smears are detailed, and the pros and cons of measuring proficiency in cytology are discussed. Despite the additional work of the rescreening project and some psychological and technical problems, it proved to be a useful measure of the laboratory's performance as a whole. One problem to be avoided in future similar studies is the creation of too many diagnostic categories. Individual testing and certification have been shown to be accurate predictors of proficiency. For cytology, such tests require a strong visual component to test interpretation and judgment skills, such as by the use of glass slides or photomicrographs. The potential of interactive videodisc technology for facilitating cytopathologic teaching and assessment is discussed.

  8. Analysis of the Pull-Up Requirement in the U.S. Marine Corps Physical Fitness Test for Female Marines

    DTIC Science & Technology

    2014-03-01

    TEST FOR FEMALE MARINES 5. FUNDING NUMBERS 6. AUTHOR(S) Sherel L. Ryan 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Naval Postgraduate...School Monterey, CA 93943-5000 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING /MONITORING AGENCY NAME(S) AND ADDRESS(ES) N/A 10. SPONSORING...modifying a fitness workout schedule that they may have performed successfully throughout their career. Further, many females may not have not

  9. Phase II Historic Resources Survey Archaeological Testing of Site 9FU416 Fulton County, Georgia

    DTIC Science & Technology

    2003-06-01

    Archaeological Park, Moundville, Alabama ) for final curation. 6 Phase 11 Testing 9FUJ 416 Chapter 3. Environmental and Cultural Overview Human...Corps of Engineers, Mobile District PO Box 2288 Mobile, Alabama 36628-0001 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING...MONITORING AGENCY REPORT NUMBER US Army Corps of Engineers, Mobile District PO Box 2288 Mobile, Alabama 36628-0001 1I. SUPPLEMENTARY NOTES DISTIR 11IT!O N

  10. An international collaboration to standardize HIV-2 viral load assays: results from the 2009 ACHI(E)V(2E) quality control study.

    PubMed

    Damond, F; Benard, A; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente; Wainberg, Mark; Taieb, Audrey; Matheron, Sophie; Chene, Genevieve; Brun-Vezinet, Francoise

    2011-10-01

    Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHI(E)V(2E) study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log(10) copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log(10) copies/ml and 3.7 log(10) copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed.

  11. An European inter-laboratory validation of alternative endpoints of the murine local lymph node assay: 2nd round.

    PubMed

    Ehling, G; Hecht, M; Heusener, A; Huesler, J; Gamer, A O; van Loveren, H; Maurer, Th; Riecke, K; Ullmann, L; Ulrich, P; Vandebriel, R; Vohr, H-W

    2005-08-15

    The original local lymph node assay (LLNA) is based on the use of radioactive labelling to measure cell proliferation. Other endpoints for the assessment of proliferation are also authorized by the OECD Guideline 429 provided there is appropriate scientific support, including full citations and description of the methodology (OECD, 2002. OECD Guideline for the Testing of Chemicals; Skin Sensitization: Local Lymph Node Assay, Guideline 429. Paris, adopted 24th April 2002.). Here, we describe the outcome of the second round of an inter-laboratory validation of alternative endpoints in the LLNA conducted in nine laboratories in Europe. The validation study was managed and supervised by the Swiss Agency for Therapeutic Products (Swissmedic) in Bern. Ear-draining lymph node (LN) weight and cell counts were used to assess LN cell proliferation instead of [3H]TdR incorporation. In addition, the acute inflammatory skin reaction was measured by ear weight determination of circular biopsies of the ears to identify skin irritation properties of the test items. The statistical analysis was performed in the department of statistics at the university of Bern. Similar to the EC(3) values defined for the radioactive method, threshold values were calculated for the endpoints measured in this modification of the LLNA. It was concluded that all parameters measured have to be taken into consideration for the categorisation of compounds due to their sensitising potencies. Therefore, an assessment scheme has been developed which turned out to be of great importance to consistently assess sensitisation versus irritancy based on the data of the different parameters. In contrast to the radioactive method, irritants have been picked up by all the laboratories applying this assessment scheme.

  12. Underground Test Area Fiscal Year 2014 Annual Quality Assurance Report Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krenzien, Susan

    2015-01-01

    This report is required by the Underground Test Area (UGTA) Quality Assurance Plan (QAP) and identifies the UGTA quality assurance (QA) activities from October 1, 2013, through September 30, 2014 (fiscal year [FY] 2014). All UGTA organizations—U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO); Desert Research Institute (DRI); Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); National Security Technologies, LLC (NSTec); Navarro-Intera, LLC (N-I); and the U.S. Geological Survey (USGS)—conducted QA activities in FY 2014. The activities included conducting oversight assessments for QAP compliance, identifying findings and completing corrective actions, evaluating laboratory performance,more » and publishing documents. UGTA Activity participants conducted 25 assessments on topics including safe operations, QAP compliance, activity planning, and sampling. These assessments are summarized in Section 2.0. Corrective actions tracked in FY 2014 are presented in Appendix A. Laboratory performance was evaluated based on three approaches: (1) established performance evaluation programs (PEPs), (2) interlaboratory comparisons, or (3) data review. The results of the laboratory performance evaluations, and interlaboratory comparison results are summarized in Section 4.0. The UGTA Activity published three public documents and a variety of other publications in FY 2014. The titles, dates, and main authors are identified in Section 5.0. The Contract Managers, Corrective Action Unit (CAU) Leads, Preemptive Review (PER) Committee members, and Topical Committee members are listed by name and organization in Section 6.0. Other activities that affected UGTA quality are discussed in Section 7.0. Section 8.0 provides the FY 2014 UGTA QA program conclusions, and Section 9.0 lists the references not identified in Section 5.0.« less

  13. An International Collaboration To Standardize HIV-2 Viral Load Assays: Results from the 2009 ACHIEV2E Quality Control Study▿

    PubMed Central

    Damond, F.; Benard, A.; Balotta, Claudia; Böni, Jürg; Cotten, Matthew; Duque, Vitor; Ferns, Bridget; Garson, Jeremy; Gomes, Perpetua; Gonçalves, Fátima; Gottlieb, Geoffrey; Kupfer, Bernd; Ruelle, Jean; Rodes, Berta; Soriano, Vicente; Wainberg, Mark; Taieb, Audrey; Matheron, Sophie; Chene, Genevieve; Brun-Vezinet, Francoise

    2011-01-01

    Accurate HIV-2 plasma viral load quantification is crucial for adequate HIV-2 patient management and for the proper conduct of clinical trials and international cohort collaborations. This study compared the homogeneity of HIV-2 RNA quantification when using HIV-2 assays from ACHIEV2E study sites and either in-house PCR calibration standards or common viral load standards supplied to all collaborators. Each of the 12 participating laboratories quantified blinded HIV-2 samples, using its own HIV-2 viral load assay and standard as well as centrally validated and distributed common HIV-2 group A and B standards (http://www.hiv.lanl.gov/content/sequence/HelpDocs/subtypes-more.html). Aliquots of HIV-2 group A and B strains, each at 2 theoretical concentrations (2.7 and 3.7 log10 copies/ml), were tested. Intralaboratory, interlaboratory, and overall variances of quantification results obtained with both standards were compared using F tests. For HIV-2 group A quantifications, overall and interlaboratory and/or intralaboratory variances were significantly lower when using the common standard than when using in-house standards at the concentration levels of 2.7 log10 copies/ml and 3.7 log10 copies/ml, respectively. For HIV-2 group B, a high heterogeneity was observed and the variances did not differ according to the type of standard used. In this international collaboration, the use of a common standard improved the homogeneity of HIV-2 group A RNA quantification only. The diversity of HIV-2 group B, particularly in PCR primer-binding regions, may explain the heterogeneity in quantification of this strain. Development of a validated HIV-2 viral load assay that accurately quantifies distinct circulating strains is needed. PMID:21813718

  14. Interlaboratory comparison of fluorocarbons-11, -12, methylchloroform and nitrous oxide measurements

    NASA Technical Reports Server (NTRS)

    Rasmussen, R. A.; Khalil, M. A. K.

    1981-01-01

    Measurements conducted by 19 participating laboratories were considered in the reported interlaboratory comparison study. The results show that there is considerable disagreement among laboratories regarding the absolute concentrations of all four trace gases (CCl3F, CCl2F2, H3CCl3, N2O). The magnitude of this disagreement is discussed. Laboratories in Group II showed considerable disagreement among themselves. Their results were scattered within large intervals of concentration. Laboratories in Group I (using common standards) were in excellent (+ or - 5%) agreement among themselves. A systematic disagreement was noted between Groups I and II laboratories. Generally, the mean values of concentrations determined from the measurements of Group II laboratories were lower than the mean values reported by Group I laboratories.

  15. An examination of the hexokinase method for serum glucose assay using external quality assessment data.

    PubMed

    Westwood, A; Bullock, D G; Whitehead, T P

    1986-01-01

    Hexokinase methods for serum glucose assay appeared to give slightly but consistently higher inter-laboratory coefficients of variation than all methods combined in the UK External Quality Assessment Scheme; their performance over a two-year period was therefore compared with that for three groups of glucose oxidase methods. This assessment showed no intrinsic inferiority in the hexokinase method. The greater variation may be due to the more heterogeneous group of instruments, particularly discrete analysers, on which the method is used. The Beckman Glucose Analyzer and Astra group (using a glucose oxidase method) showed the least inter-laboratory variability but also the lowest mean value. No comment is offered on the absolute accuracy of any of the methods.

  16. LipidQC: Method Validation Tool for Visual Comparison to SRM 1950 Using NIST Interlaboratory Comparison Exercise Lipid Consensus Mean Estimate Values.

    PubMed

    Ulmer, Candice Z; Ragland, Jared M; Koelmel, Jeremy P; Heckert, Alan; Jones, Christina M; Garrett, Timothy J; Yost, Richard A; Bowden, John A

    2017-12-19

    As advances in analytical separation techniques, mass spectrometry instrumentation, and data processing platforms continue to spur growth in the lipidomics field, more structurally unique lipid species are detected and annotated. The lipidomics community is in need of benchmark reference values to assess the validity of various lipidomics workflows in providing accurate quantitative measurements across the diverse lipidome. LipidQC addresses the harmonization challenge in lipid quantitation by providing a semiautomated process, independent of analytical platform, for visual comparison of experimental results of National Institute of Standards and Technology Standard Reference Material (SRM) 1950, "Metabolites in Frozen Human Plasma", against benchmark consensus mean concentrations derived from the NIST Lipidomics Interlaboratory Comparison Exercise.

  17. A Recombinant Positive Control for Serology Diagnostic Tests Supporting Elimination of Onchocerca volvulus.

    PubMed

    Golden, Allison; Stevens, Eric J; Yokobe, Lindsay; Faulx, Dunia; Kalnoky, Michael; Peck, Roger; Valdez, Melissa; Steel, Cathy; Karabou, Potochoziou; Banla, Méba; Soboslay, Peter T; Adade, Kangi; Tekle, Afework H; Cama, Vitaliano A; Fischer, Peter U; Nutman, Thomas B; Unnasch, Thomas R; de los Santos, Tala; Domingo, Gonzalo J

    2016-01-01

    Serological assays for human IgG4 to the Onchocerca volvulus antigen Ov16 have been used to confirm elimination of onchocerciasis in much of the Americas and parts of Africa. A standardized source of positive control antibody (human anti-Ov16 IgG4) will ensure the quality of surveillance data using these tests. A recombinant human IgG4 antibody to Ov16 was identified by screening against a synthetic human Fab phage display library and converted into human IgG4. This antibody was developed into different positive control formulations for enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT) platforms. Variation in ELISA results and utility as a positive control of the antibody were assessed from multiple laboratories. Temperature and humidity conditions were collected across seven surveillance activities from 2011-2014 to inform stability requirements for RDTs and positive controls. The feasibility of the dried positive control for RDT was evaluated during onchocerciasis surveillance activity in Togo, in 2014. When the anti-Ov16 IgG4 antibody was used as a standard dilution in horseradish peroxidase (HRP) and alkaline phosphatase (AP) ELISAs, the detection limits were approximately 1ng/mL by HRP ELISA and 10ng/mL by AP ELISA. Positive control dilutions and spiked dried blood spots (DBS) produced similar ELISA results. Used as a simple plate normalization control, the positive control antibody may improve ELISA data comparison in the context of inter-laboratory variation. The aggregate temperature and humidity monitor data informed temperature parameters under which the dried positive control was tested and are applicable inputs for testing of diagnostics tools intended for sub-Saharan Africa. As a packaged positive control for Ov16 RDTs, stability of the antibody was demonstrated for over six months at relevant temperatures in the laboratory and for over 15 weeks under field conditions. The recombinant human anti-Ov16 IgG4 antibody-based positive control will benefit inter-laboratory validation of ELISA assays and serve as quality control (QC) reagents for Ov16 RDTs at different points of the supply chain from manufacturer to field use.

  18. Proficiency testing as a basis for estimating uncertainty of measurement: application to forensic alcohol and toxicology quantitations.

    PubMed

    Wallace, Jack

    2010-05-01

    While forensic laboratories will soon be required to estimate uncertainties of measurement for those quantitations reported to the end users of the information, the procedures for estimating this have been little discussed in the forensic literature. This article illustrates how proficiency test results provide the basis for estimating uncertainties in three instances: (i) For breath alcohol analyzers the interlaboratory precision is taken as a direct measure of uncertainty. This approach applies when the number of proficiency tests is small. (ii) For blood alcohol, the uncertainty is calculated from the differences between the laboratory's proficiency testing results and the mean quantitations determined by the participants; this approach applies when the laboratory has participated in a large number of tests. (iii) For toxicology, either of these approaches is useful for estimating comparability between laboratories, but not for estimating absolute accuracy. It is seen that data from proficiency tests enable estimates of uncertainty that are empirical, simple, thorough, and applicable to a wide range of concentrations.

  19. The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma: a global proficiency testing program.

    PubMed

    Burger, David; Teulen, Marga; Eerland, Jaco; Harteveld, Anneke; Aarnoutse, Rob; Touw, Daan

    2011-04-01

    The International Interlaboratory Quality Control Program for Measurement of Antiretroviral Drugs in Plasma was initiated in 1999 by Radboud University Nijmegen Medical Center, The Netherlands, and continued later on in collaboration with the Dutch Association for Quality Assessment in Therapeutic Drug Monitoring and Clinical Toxicology (www.kkgt.nl). The aim of this analysis was to evaluate the first 10 years of the Program and to determine variables associated with reporting of less accurate results. Two rounds are organized annually in which blind samples are shipped to participants containing a low, medium, or high concentration of each antiretroviral drug. Any reported result that deviates more than 20% from the spiked concentration is defined as inaccurate. By the end of 2009, the number of laboratories participating in the Program had increased to 56; 44 (79%) are located in Europe. A total of 12,798 test results was available for analysis, of which 2104 (16.4%) were reported as inaccurate. Performance was best for samples containing nevirapine (mean of inadequate scores per round: 11.1%) and lopinavir (11.9%) and worst for indinavir (18.7%), atazanavir (18.9%), saquinavir (19.6%), and nelfinavir (21.3%). High and medium concentrations were less frequently reported as inaccurate than low concentrations: 13.5%, 13.0%, and 22.4%, respectively. Although the overall performance of the laboratories varied per year, a trend was visible for improvement over time with 19.9% of the results being inaccurate in 2002 (n = 20 laboratories) to 15.7% in 2009 (n = 56 laboratories). The Program provides a proficiency testing program in which laboratories are alerted to potential analytical errors while performing therapeutic drug monitoring in HIV-infected patients. Laboratories should put more effort in adequately analyzing concentrations of antiretroviral drugs with low minimum effective concentrations.

  20. Variability in P-Glycoprotein Inhibitory Potency (IC50) Using Various in Vitro Experimental Systems: Implications for Universal Digoxin Drug-Drug Interaction Risk Assessment Decision Criteria

    PubMed Central

    Bentz, Joe; O’Connor, Michael P.; Bednarczyk, Dallas; Coleman, JoAnn; Lee, Caroline; Palm, Johan; Pak, Y. Anne; Perloff, Elke S.; Reyner, Eric; Balimane, Praveen; Brännström, Marie; Chu, Xiaoyan; Funk, Christoph; Guo, Ailan; Hanna, Imad; Herédi-Szabó, Krisztina; Hillgren, Kate; Li, Libin; Hollnack-Pusch, Evelyn; Jamei, Masoud; Lin, Xuena; Mason, Andrew K.; Neuhoff, Sibylle; Patel, Aarti; Podila, Lalitha; Plise, Emile; Rajaraman, Ganesh; Salphati, Laurent; Sands, Eric; Taub, Mitchell E.; Taur, Jan-Shiang; Weitz, Dietmar; Wortelboer, Heleen M.; Xia, Cindy Q.; Xiao, Guangqing; Yabut, Jocelyn; Yamagata, Tetsuo; Zhang, Lei

    2013-01-01

    A P-glycoprotein (P-gp) IC50 working group was established with 23 participating pharmaceutical and contract research laboratories and one academic institution to assess interlaboratory variability in P-gp IC50 determinations. Each laboratory followed its in-house protocol to determine in vitro IC50 values for 16 inhibitors using four different test systems: human colon adenocarcinoma cells (Caco-2; eleven laboratories), Madin-Darby canine kidney cells transfected with MDR1 cDNA (MDCKII-MDR1; six laboratories), and Lilly Laboratories Cells—Porcine Kidney Nr. 1 cells transfected with MDR1 cDNA (LLC-PK1-MDR1; four laboratories), and membrane vesicles containing human P-glycoprotein (P-gp; five laboratories). For cell models, various equations to calculate remaining transport activity (e.g., efflux ratio, unidirectional flux, net-secretory-flux) were also evaluated. The difference in IC50 values for each of the inhibitors across all test systems and equations ranged from a minimum of 20- and 24-fold between lowest and highest IC50 values for sertraline and isradipine, to a maximum of 407- and 796-fold for telmisartan and verapamil, respectively. For telmisartan and verapamil, variability was greatly influenced by data from one laboratory in each case. Excluding these two data sets brings the range in IC50 values for telmisartan and verapamil down to 69- and 159-fold. The efflux ratio-based equation generally resulted in severalfold lower IC50 values compared with unidirectional or net-secretory-flux equations. Statistical analysis indicated that variability in IC50 values was mainly due to interlaboratory variability, rather than an implicit systematic difference between test systems. Potential reasons for variability are discussed and the simplest, most robust experimental design for P-gp IC50 determination proposed. The impact of these findings on drug-drug interaction risk assessment is discussed in the companion article (Ellens et al., 2013) and recommendations are provided. PMID:23620485

  1. Pathogen Reduction of Fresh Whole Blood for Military and Civilian Use

    DTIC Science & Technology

    2010-04-01

    NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT...treatment with 80 J/mLRBC in the Mirasol System. Strain of bacteria tested # of units positive/ # of units tested Serratia marcescens 0/3 Yersinia

  2. Biomedical Advanced Research and Development Authority - PHE

    Science.gov Websites

    Content BARDA News March 29, 2018: FDA approves Leukine for Acute Radiation Syndrome October 6, 2017: HHS pursues therapeutic for radiation injury affecting blood platelets October 6, 2017: HHS sponsors : HHS sponsors development of two tests for radiation exposure October 3, 2017: HHS, Regeneron partner

  3. Testing New Survey Questions of Sexual Harassment and Sexual Assault

    DTIC Science & Technology

    2011-01-01

    Technical Report No. 100-11 REPORT DOCUMENTATION PAGE Standard Form 298 (Rev. 8 /98) Prescribed by ANSI Std. Z39.18 Form Approved OMB No. 0704...S) AND ADDRESS(ES) 8 . PERFORMING ORGANIZATION REPORT NUMBER 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 9... 8 Conclusion

  4. Upgrade and Operation of the DNA Dust Erosion Test Facility

    DTIC Science & Technology

    1990-11-01

    Robert G. Oeding PDA Engineering 2975 Redhill Avenue Costa Mesa, CA 92626 November 1990 ,)TICI-i -LECTE NOV 2 7,19W Techical ReportD CONTRACT No. DNA...Engineering 2975 Redhill Avenue Costa Mesa, CA 92626 PDA-TR-1385-03-01 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING

  5. Advancing the Use of Passive Sampling in Risk Assessment and Management of Sediments Contaminated with Hydrophobic Organic Chemicals: Results of an International Ex Situ Passive Sampling Interlaboratory Comparison

    PubMed Central

    2018-01-01

    This work presents the results of an international interlaboratory comparison on ex situ passive sampling in sediments. The main objectives were to map the state of the science in passively sampling sediments, identify sources of variability, provide recommendations and practical guidance for standardized passive sampling, and advance the use of passive sampling in regulatory decision making by increasing confidence in the use of the technique. The study was performed by a consortium of 11 laboratories and included experiments with 14 passive sampling formats on 3 sediments for 25 target chemicals (PAHs and PCBs). The resulting overall interlaboratory variability was large (a factor of ∼10), but standardization of methods halved this variability. The remaining variability was primarily due to factors not related to passive sampling itself, i.e., sediment heterogeneity and analytical chemistry. Excluding the latter source of variability, by performing all analyses in one laboratory, showed that passive sampling results can have a high precision and a very low intermethod variability (

  6. First Interlaboratory Comparison on Calibration of Temperature-Controlled Enclosures in Turkey

    NASA Astrophysics Data System (ADS)

    Uytun, A.; Kalemci, M.

    2017-11-01

    The number of accredited laboratories in the field of calibration of temperature-controlled enclosures has been increasing in Turkey. One of the main criteria demonstrating the competence of a calibration laboratory is successful participation in interlaboratory comparisons. Therefore, TUBITAK UME Temperature Laboratory organized the first interlaboratory comparison on "Calibration of Temperature-Controlled Enclosures" in Turkey as a pilot laboratory between January and November, 2013. Forty accredited laboratories which provide routine calibration services to the industry in this field participated in the comparison. The standards used during the comparison was a climatic chamber for the measurements at -40 {°}C, -20 {°}C, 40 {°}C and 100 {°}C and an oven for the measurements at 200 {°}C. The protocol of the comparison was prepared considering guide EURAMET cg-20 and BS EN/IEC standards 600068-3-5 and 600068-3-11. During the comparison measurements, each participant had the liberty to choose the most convenient calibration points in terms of their accreditation scope among the values mentioned above and carried out on-site measurements at UME. The details and the results of this comparison are given in the paper. Determination of the statistical consistency of the results with the uncertainties given by the participants can be assessed by the method of En value assessment for each laboratory. En values for all measurement results based on the results of pilot and participating laboratories were calculated.

  7. Biological dosimetry by the triage dicentric chromosome assay: potential implications for treatment of acute radiation syndrome in radiological mass casualties.

    PubMed

    Romm, Horst; Wilkins, Ruth C; Coleman, C Norman; Lillis-Hearne, Patricia K; Pellmar, Terry C; Livingston, Gordon K; Awa, Akio A; Jenkins, Mark S; Yoshida, Mitsuaki A; Oestreicher, Ursula; Prasanna, Pataje G S

    2011-03-01

    Biological dosimetry is an essential tool for estimating radiation dose. The dicentric chromosome assay (DCA) is currently the tool of choice. Because the assay is labor-intensive and time-consuming, strategies are needed to increase throughput for use in radiation mass casualty incidents. One such strategy is to truncate metaphase spread analysis for triage dose estimates by scoring 50 or fewer metaphases, compared to a routine analysis of 500 to 1000 metaphases, and to increase throughput using a large group of scorers in a biodosimetry network. Previously, the National Institutes for Allergies and Infectious Diseases (NIAID) and the Armed Forces Radiobiology Research Institute (AFRRI) sponsored a double-blinded interlaboratory comparison among five established international cytogenetic biodosimetry laboratories to determine the variability in calibration curves and in dose measurements in unknown, irradiated samples. In the present study, we further analyzed the published data from this previous study to investigate how the number of metaphase spreads influences dose prediction accuracy and how this information could be of value in the triage and management of people at risk for the acute radiation syndrome (ARS). Although, as expected, accuracy decreased with lower numbers of metaphase spreads analyzed, predicted doses by the laboratories were in good agreement and were judged to be adequate to guide diagnosis and treatment of ARS. These results demonstrate that for rapid triage, a network of cytogenetic biodosimetry laboratories can accurately assess doses even with a lower number of scored metaphases.

  8. Does bisphenol A induce superfeminization in Marisa cornuarietis? Part I: intra- and inter-laboratory variability in test endpoints.

    PubMed

    Forbes, Valery E; Selck, Henriette; Palmqvist, Annemette; Aufderheide, John; Warbritton, Ryan; Pounds, Nadine; Thompson, Roy; van der Hoeven, Nelly; Caspers, Norbert

    2007-03-01

    It has been claimed that bisphenol A (BPA) induces superfeminization in the freshwater gastropod, Marisa cornuarietis. To explore the reproducibility of prior work, here we present results from a three-laboratory study, the objectives of which were to determine the mean and variability in test endpoints (i.e., adult fecundity, egg hatchability, and juvenile growth) under baseline conditions and to identify the sources of variability. A major source of variability for all of the measured endpoints was due to differences within and among individuals. With few exceptions, variability among laboratories and among replicate tanks within laboratories contributed little to the observed variability in endpoints. The results highlight the importance of obtaining basic knowledge of husbandry requirements and baseline information on life-history traits of potential test species prior to designing toxicity test protocols. Understanding of the levels and sources of endpoint variability is essential so that statistically robust and ecologically relevant tests of chemicals can be conducted.

  9. Accreditation of medical laboratories in Croatia--experiences of the Institute of Clinical Chemistry, University Hospital "Merkur", Zagreb.

    PubMed

    Flegar-Mestrić, Zlata; Nazor, Aida; Perkov, Sonja; Surina, Branka; Kardum-Paro, Mirjana Mariana; Siftar, Zoran; Sikirica, Mirjana; Sokolić, Ivica; Ozvald, Ivan; Vidas, Zeljko

    2010-03-01

    Since 2003 when the international norm for implementation of quality management in medical laboratories (EN ISO 15189, Medical laboratories--Particular requirements for quality and competence) was established and accepted, accreditation has become practical, generally accepted method of quality management and confirmation of technical competence of medical laboratories in the whole world. This norm has been translated into Croatian and accepted by the Croatian Institute for Norms as Croatian norm. Accreditation is carried out on voluntary basis by the Croatian Accreditation Agency that has up to now accredited two clinical medical biochemical laboratories in the Republic of Croatia. Advantages of accredited laboratory lie in its documented management system, constant improvement and training, reliability of test results, establishing users' trust in laboratory services, test results comparability and interlaboratory (international) test results acceptance by adopting the concept of metrological traceability in laboratory medicine.

  10. Interlaboratory Comparison of Methods Determining the Botanical Composition of Animal Feed.

    PubMed

    Braglia, Luca; Morello, Laura; Gavazzi, Floriana; Gianì, Silvia; Mastromauro, Francesco; Breviario, Diego; Cardoso, Hélia Guerra; Valadas, Vera; Campos, Maria Doroteia

    2018-01-01

    A consortium of European enterprises and research institutions has been engaged in the Feed-Code Project with the aim of addressing the requirements stated in European Union Regulation No. 767/2009, concerning market placement and use of feed of known and ascertained botanical composition. Accordingly, an interlaboratory trial was set up to compare the performance of different assays based either on optical microscope or DNA analysis for the qualitative and quantitative identification of the composition of compound animal feeds. A tubulin-based polymorphism method, on which the Feed-Code platform was developed, provided the most accurate results. The present study highlights the need for the performance of ring trials for the determination of the botanical composition of animal feeds and raises an alarm on the actual status of analytical inaccuracy.

  11. Interlaboratory Comparison of Magnetic Thin Film Measurements.

    PubMed

    da Silva, F C S; Wang, C M; Pappas, D P

    2003-01-01

    A potential low magnetic moment standard reference material (SRM) was studied in an interlaboratory comparison. The mean and the standard deviation of the saturation moment m s, the remanent moment m r, and the intrinsic coercivity H c of nine samples were extracted from hysteresis-loop measurements. Samples were measured by thirteen laboratories using inductive-field loopers, vibrating-sample magnetometers, alternating-gradient force magnetometers, and superconducting quantum-interference-device magnetometers. NiFe films on Si substrates had saturation moment measurements reproduced within 5 % variation among the laboratories. The results show that a good candidate for an SRM must have a highly square hysteresis loop (m r/m s > 90 %), H c ≈ 400 A·m(-1) (5 Oe), and m s ≈ 2 × 10(-7) A·m(2) (2 × 10(-4) emu).

  12. Interlaboratory quality control of total HIV-1 DNA load measurement for multicenter reservoir studies.

    PubMed

    Gantner, Pierre; Mélard, Adeline; Damond, Florence; Delaugerre, Constance; Dina, Julia; Gueudin, Marie; Maillard, Anne; Sauné, Karine; Rodallec, Audrey; Tuaillon, Edouard; Plantier, Jean-Christophe; Rouzioux, Christine; Avettand-Fenoel, Véronique

    2017-11-01

    Viral reservoirs represent an important barrier to HIV cure. Accurate markers of HIV reservoirs are needed to develop multicenter studies. The aim of this multicenter quality control (QC) was to evaluate the inter-laboratory reproducibility of total HIV-1-DNA quantification. Ten laboratories of the ANRS-AC11 working group participated by quantifying HIV-DNA with a real-time qPCR assay (Biocentric) in four samples (QCMD). Good reproducibility was found between laboratories (standard deviation ≤ 0.2 log 10 copies/10 6 PBMC) for the three positive QC that were correctly classified by each laboratory (QC1

  13. The Effects of Participation in School Instrumental Music Programs on Student Academic Achievement and School Attendance

    ERIC Educational Resources Information Center

    Davenport, Kevin O.

    2010-01-01

    This study examined whether or not students that participated in a school sponsored instrumental music program had higher academic achievement and attendance than students that did not participate in a school sponsor instrumental music program. Units of measurement included standardized test scores and attendance, without taking into consideration…

  14. Round-robin test for the cell-of-origin classification of diffuse large B-cell lymphoma-a feasibility study using full slide staining.

    PubMed

    Reinke, Sarah; Richter, Julia; Fend, Falko; Feller, Alfred; Hansmann, Martin-Leo; Hüttl, Katrin; Oschlies, Ilske; Ott, German; Möller, Peter; Rosenwald, Andreas; Stein, Harald; Altenbuchinger, Michael; Spang, Rainer; Klapper, Wolfram

    2018-05-05

    Diffuse large B-cell lymphoma (DLBCL) is subdivided by gene expression analysis (GEP) into two molecular subtypes named germinal center B-cell-like (GCB) and activated B-cell-like (ABC) after their putative cell-of-origin (COO). Determination of the COO is considered mandatory in any new-diagnosed DLBCL, not otherwise specified according to the updated WHO classification. Despite the fact that pathologists are free to choose the method for COO classification, immunohistochemical (IHC) assays are most widely used. However, to the best of our knowledge, no round-robin test to evaluate the interlaboratory variability has been published so far. Eight hematopathology laboratories participated in an interlaboratory test for COO classification of 10 DLBCL tumors using the IHC classifier comprising the expression of CD10, BCL6, and MUM1 (so-called Hans classifier). The results were compared with GEP for COO signature and, in a subset, with results obtained by image analysis. In 7/10 cases (70%), at least seven laboratories assigned a given case to the same COO subtype (one center assessed one sample as not analyzable), which was in agreement with the COO subtype determined by GEP. The results in 3/10 cases (30%) revealed discrepancies between centers and/or between IHC and GEP subtype. Whereas the CD10 staining results were highly reproducible, staining for MUM1 was inconsistent in 50% and for BCL6 in 40% of cases. Image analysis of 16 slides stained for BCL6 (N = 8) and MUM1 (N = 8) of the two cases with the highest disagreement in COO classification were in line with the score of the pathologists in 14/16 stainings analyzed (87.5%). This study describes the first round-robin test for COO subtyping in DLBCL using IHC and demonstrates that COO classification using the Hans classifier yields consistent results among experienced hematopathologists, even when variable staining protocols are used. Data from this small feasibility study need to be validated in larger cohorts.

  15. Estimation and uncertainty analysis of dose response in an inter-laboratory experiment

    NASA Astrophysics Data System (ADS)

    Toman, Blaza; Rösslein, Matthias; Elliott, John T.; Petersen, Elijah J.

    2016-02-01

    An inter-laboratory experiment for the evaluation of toxic effects of NH2-polystyrene nanoparticles on living human cancer cells was performed with five participating laboratories. Previously published results from nanocytoxicity assays are often contradictory, mostly due to challenges related to producing a reliable cytotoxicity assay protocol for use with nanomaterials. Specific challenges include reproducibility preparing nanoparticle dispersions, biological variability from testing living cell lines, and the potential for nano-related interference effects. In this experiment, such challenges were addressed by developing a detailed experimental protocol and using a specially designed 96-well plate layout which incorporated a range of control measurements to assess multiple factors such as nanomaterial interference, pipetting accuracy, cell seeding density, and instrument performance. Detailed data analysis of these control measurements showed that good control of the experiments was attained by all participants in most cases. The main measurement objective of the study was the estimation of a dose response relationship between concentration of the nanoparticles and metabolic activity of the living cells, under several experimental conditions. The dose curve estimation was achieved by imbedding a three parameter logistic curve in a three level Bayesian hierarchical model, accounting for uncertainty due to all known experimental conditions as well as between laboratory variability in a top-down manner. Computation was performed using Markov Chain Monte Carlo methods. The fit of the model was evaluated using Bayesian posterior predictive probabilities and found to be satisfactory.

  16. Estimation of discrimination errors in the technique for determining the geographic origin of onions by mineral composition: interlaboratory study.

    PubMed

    Ariyama, Kaoru; Kadokura, Masashi; Suzuki, Tadanao

    2008-01-01

    Techniques to determine the geographic origin of foods have been developed for various agricultural and fishery products, and they have used various principles. Some of these techniques are already in use for checking the authenticity of the labeling. Many are based on multielement analysis and chemometrics. We have developed such a technique to determine the geographic origin of onions (Allium cepa L.). This technique, which determines whether an onion is from outside Japan, is designed for onions labeled as having a geographic origin of Hokkaido, Hyogo, or Saga, the main onion production areas in Japan. However, estimations of discrimination errors for this technique have not been fully conducted; they have been limited to those for discrimination models and do not include analytical errors. Interlaboratory studies were conducted to estimate the analytical errors of the technique. Four collaborators each determined 11 elements (Na, Mg, P, Mn, Zn, Rb, Sr, Mo, Cd, Cs, and Ba) in 4 test materials of fresh and dried onions. Discrimination errors in this technique were estimated by summing (1) individual differences within lots, (2) variations between lots from the same production area, and (3) analytical errors. The discrimination errors for onions from Hokkaido, Hyogo, and Saga were estimated to be 2.3, 9.5, and 8.0%, respectively. Those for onions from abroad in determinations targeting Hokkaido, Hyogo, and Saga were estimated to be 28.2, 21.6, and 21.9%, respectively.

  17. Effect of Hollow Sphere Size and Distribution on the Quasi-Static and High Strain Rate Compressive Properties of Al-A380-Al2O3 Syntactic Foams

    DTIC Science & Technology

    2012-01-01

    TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) University Of Wisconsin,Milwaukee Materials Department,P.O. Box...784,Milwaukee,WI,53201 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSOR/MONITOR’S...diameter = 14.3 mm length = 12.7 mm). Testing was carried out using a SATEC Model 50Ud Universal Testing Machine at constant crosshead speed with an

  18. Quantifying inter-laboratory variability in stable isotope analysis of ancient skeletal remains.

    PubMed

    Pestle, William J; Crowley, Brooke E; Weirauch, Matthew T

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application.

  19. Quantifying Inter-Laboratory Variability in Stable Isotope Analysis of Ancient Skeletal Remains

    PubMed Central

    Pestle, William J.; Crowley, Brooke E.; Weirauch, Matthew T.

    2014-01-01

    Over the past forty years, stable isotope analysis of bone (and tooth) collagen and hydroxyapatite has become a mainstay of archaeological and paleoanthropological reconstructions of paleodiet and paleoenvironment. Despite this method's frequent use across anthropological subdisciplines (and beyond), the present work represents the first attempt at gauging the effects of inter-laboratory variability engendered by differences in a) sample preparation, and b) analysis (instrumentation, working standards, and data calibration). Replicate analyses of a 14C-dated ancient human bone by twenty-one archaeological and paleoecological stable isotope laboratories revealed significant inter-laboratory isotopic variation for both collagen and carbonate. For bone collagen, we found a sizeable range of 1.8‰ for δ13Ccol and 1.9‰ for δ15Ncol among laboratories, but an interpretatively insignificant average pairwise difference of 0.2‰ and 0.4‰ for δ13Ccol and δ15Ncol respectively. For bone hydroxyapatite the observed range increased to a troublingly large 3.5‰ for δ13Cap and 6.7‰ for δ18Oap, with average pairwise differences of 0.6‰ for δ13Cap and a disquieting 2.0‰ for δ18Oap. In order to assess the effects of preparation versus analysis on isotopic variability among laboratories, a subset of the samples prepared by the participating laboratories were analyzed a second time on the same instrument. Based on this duplicate analysis, it was determined that roughly half of the isotopic variability among laboratories could be attributed to differences in sample preparation, with the other half resulting from differences in analysis (instrumentation, working standards, and data calibration). These findings have serious implications for choices made in the preparation and extraction of target biomolecules, the comparison of results obtained from different laboratories, and the interpretation of small differences in bone collagen and hydroxyapatite isotope values. To address the issues arising from inter-laboratory comparisons, we devise a novel measure we term the Minimum Meaningful Difference (MMD), and demonstrate its application. PMID:25061843

  20. Consensus building for interlaboratory studies, key comparisons, and meta-analysis

    NASA Astrophysics Data System (ADS)

    Koepke, Amanda; Lafarge, Thomas; Possolo, Antonio; Toman, Blaza

    2017-06-01

    Interlaboratory studies in measurement science, including key comparisons, and meta-analyses in several fields, including medicine, serve to intercompare measurement results obtained independently, and typically produce a consensus value for the common measurand that blends the values measured by the participants. Since interlaboratory studies and meta-analyses reveal and quantify differences between measured values, regardless of the underlying causes for such differences, they also provide so-called ‘top-down’ evaluations of measurement uncertainty. Measured values are often substantially over-dispersed by comparison with their individual, stated uncertainties, thus suggesting the existence of yet unrecognized sources of uncertainty (dark uncertainty). We contrast two different approaches to take dark uncertainty into account both in the computation of consensus values and in the evaluation of the associated uncertainty, which have traditionally been preferred by different scientific communities. One inflates the stated uncertainties by a multiplicative factor. The other adds laboratory-specific ‘effects’ to the value of the measurand. After distinguishing what we call recipe-based and model-based approaches to data reductions in interlaboratory studies, we state six guiding principles that should inform such reductions. These principles favor model-based approaches that expose and facilitate the critical assessment of validating assumptions, and give preeminence to substantive criteria to determine which measurement results to include, and which to exclude, as opposed to purely statistical considerations, and also how to weigh them. Following an overview of maximum likelihood methods, three general purpose procedures for data reduction are described in detail, including explanations of how the consensus value and degrees of equivalence are computed, and the associated uncertainty evaluated: the DerSimonian-Laird procedure; a hierarchical Bayesian procedure; and the Linear Pool. These three procedures have been implemented and made widely accessible in a Web-based application (NIST Consensus Builder). We illustrate principles, statistical models, and data reduction procedures in four examples: (i) the measurement of the Newtonian constant of gravitation; (ii) the measurement of the half-lives of radioactive isotopes of caesium and strontium; (iii) the comparison of two alternative treatments for carotid artery stenosis; and (iv) a key comparison where the measurand was the calibration factor of a radio-frequency power sensor.

  1. Evaluation of Brazilian Sugarcane Bagasse Characterization: An Interlaboratory Comparison Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sluiter, Justin B.; Chum, Helena; Gomes, Absai C.

    2016-05-01

    This paper describes a study of the variability of measured composition for a single bulk sugarcane bagasse conducted across eight laboratories using similar analytical methods, with the purpose of determining the expected variation for compositional analysis performed by different laboratories. The results show good agreement of measured composition within a single laboratory, but greater variability when results are compared among laboratories. These interlaboratory variabilities do not seem to be associated with a specific method or technique or any single piece of instrumentation. The summary censored statistics provide mean values and pooled standard deviations as follows: total extractives 6.7% (0.6%), wholemore » ash 1.5% (0.2%), glucan 42.3% (1.2%), xylan 22.3% (0.5%), total lignin 21.3% (0.4%), and total mass closure 99.4% (2.9%).« less

  2. Inter-laboratory comparison measurements of radiochemical laboratories in Slovakia.

    PubMed

    Meresová, J; Belanová, A; Vrsková, M

    2010-01-01

    The first inter-laboratory comparison organized by the radiochemistry laboratory of Water Research Institute (WRI) in Bratislava was carried out in 1993 and since then is it realized on an annual basis and about 10 radiochemical laboratories from all over Slovakia are participating. The gross alpha and gross beta activities, and the activity concentrations of (222)Rn, tritium, and (226)Ra, and U(nat) concentration in synthetic water samples are compared. The distributed samples are covering the concentration range prevailing in potable and surface waters and are prepared by dilution of certified reference materials. Over the course of the years 1993-2008, we observed the improvement in the quality of results for most of the laboratories. However, the success rate of the gross alpha determination activity is not improving as much as the other parameters. Copyright 2009 Elsevier Ltd. All rights reserved.

  3. First Worldwide Proficiency Study on Variable-Number Tandem-Repeat Typing of Mycobacterium tuberculosis Complex Strains

    PubMed Central

    de Beer, Jessica L.; Kremer, Kristin; Ködmön, Csaba; Supply, Philip

    2012-01-01

    Although variable-number tandem-repeat (VNTR) typing has gained recognition as the new standard for the DNA fingerprinting of Mycobacterium tuberculosis complex (MTBC) isolates, external quality control programs have not yet been developed. Therefore, we organized the first multicenter proficiency study on 24-locus VNTR typing. Sets of 30 DNAs of MTBC strains, including 10 duplicate DNA samples, were distributed among 37 participating laboratories in 30 different countries worldwide. Twenty-four laboratories used an in-house-adapted method with fragment sizing by gel electrophoresis or an automated DNA analyzer, nine laboratories used a commercially available kit, and four laboratories used other methods. The intra- and interlaboratory reproducibilities of VNTR typing varied from 0% to 100%, with averages of 72% and 60%, respectively. Twenty of the 37 laboratories failed to amplify particular VNTR loci; if these missing results were ignored, the number of laboratories with 100% interlaboratory reproducibility increased from 1 to 5. The average interlaboratory reproducibility of VNTR typing using a commercial kit was better (88%) than that of in-house-adapted methods using a DNA analyzer (70%) or gel electrophoresis (50%). Eleven laboratories using in-house-adapted manual typing or automated typing scored inter- and intralaboratory reproducibilities of 80% or higher, which suggests that these approaches can be used in a reliable way. In conclusion, this first multicenter study has documented the worldwide quality of VNTR typing of MTBC strains and highlights the importance of international quality control to improve genotyping in the future. PMID:22170917

  4. Interlaboratory comparability of serum cotinine measurements at smoker and nonsmoker concentration levels: A round-robin study

    PubMed Central

    Jacob, Peyton; Holiday, David B.; Benowitz, Neal L.; Sosnoff, Connie S.; Doig, Mira V.; Feyerabend, Colin; Aldous, Kenneth M.; Sharifi, Mehran; Kellogg, Mark D.; Langman, Loralie J.

    2009-01-01

    Introduction: Cotinine, the primary proximate metabolite of nicotine, is commonly measured as an index of exposure to tobacco in both active users of tobacco and nonsmokers with possible exposure to secondhand smoke (SHS). A number of laboratories have implemented analyses for measuring serum cotinine in recent years, but there have been few interlaboratory comparisons of the results. Among nonsmokers exposed to SHS, the concentration of cotinine in blood can be quite low, and extensive variability in these measurements has been reported in the past. Methods: In this study, a group of seven laboratories, all experienced in serum cotinine analysis, measured eight coded serum pools with concentrations ranging from background levels of about 0.05 ng/ml to relatively high concentrations in the active smokers range. All laboratories used either gas–liquid chromatography with nitrogen–phosphorus detection or liquid chromatography with mass spectrometric detection. Results: All seven laboratories reliably measured the cotinine concentrations in samples that were within the range of their methods. In each case, the results for the pools were correctly ranked in order, and no significant interlaboratory bias was observed at the 5% level of significance for results from any of the pools. Discussion: We conclude that present methods of chromatographic analysis of serum cotinine, as used by these experienced laboratories, are capable of providing accurate and precise results in both the smoker and the nonsmoker concentration range. PMID:19933777

  5. Bias from two analytical laboratories involved in a long-term air monitoring program measuring organic pollutants in the Arctic: a quality assurance/quality control assessment.

    PubMed

    Su, Yushan; Hung, Hayley; Stern, Gary; Sverko, Ed; Lao, Randy; Barresi, Enzo; Rosenberg, Bruno; Fellin, Phil; Li, Henrik; Xiao, Hang

    2011-11-01

    Initiated in 1992, air monitoring of organic pollutants in the Canadian Arctic provided spatial and temporal trends in support of Canada's participation in the Stockholm Convention of Persistent Organic Pollutants. The specific analytical laboratory charged with this task was changed in 2002 while field sampling protocols remained unchanged. Three rounds of intensive comparison studies were conducted in 2004, 2005, and 2008 to assess data comparability between the two laboratories. Analysis was compared for organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) in standards, blind samples of mixed standards and extracts of real air samples. Good measurement accuracy was achieved for both laboratories when standards were analyzed. Variation of measurement accuracy over time was found for some OCPs and PCBs in standards on a random and non-systematic manner. Relatively low accuracy in analyzing blind samples was likely related to the process of sample purification. Inter-laboratory measurement differences for standards (<30%) and samples (<70%) were generally less than or comparable to those reported in a previous inter-laboratory study with 21 participating laboratories. Regression analysis showed inconsistent data comparability between the two laboratories during the initial stages of the study. These inter-laboratory differences can complicate abilities to discern long-term trends of pollutants in a given sampling site. It is advisable to maintain long-term measurements with minimal changes in sample analysis.

  6. Development, evaluation and application of performance-based brake testing technologies field test : executive summary

    DOT National Transportation Integrated Search

    1999-09-01

    This report presents the results of the field test portion of the Development, Evaluation, and Application of Performance-Based Brake Testing Technologies sponsored by the Federal Highway Administrations (FHWA) Office of Motor Carriers.

  7. Proficiency Testing for Evaluating Aerospace Materials Test Anomalies

    NASA Technical Reports Server (NTRS)

    Hirsch, D.; Motto, S.; Peyton, S.; Beeson, H.

    2006-01-01

    ASTM G 86 and ASTM G 74 are commonly used to evaluate materials susceptibility to ignition in liquid and gaseous oxygen systems. However, the methods have been known for their lack of repeatability. The inherent problems identified with the test logic would either not allow precise identification or the magnitude of problems related to running the tests, such as lack of consistency of systems performance, lack of adherence to procedures, etc. Excessive variability leads to increasing instances of accepting the null hypothesis erroneously, and so to the false logical deduction that problems are nonexistent when they really do exist. This paper attempts to develop and recommend an approach that could lead to increased accuracy in problem diagnostics by using the 50% reactivity point, which has been shown to be more repeatable. The initial tests conducted indicate that PTFE and Viton A (for pneumatic impact) and Buna S (for mechanical impact) would be good choices for additional testing and consideration for inter-laboratory evaluations. The approach presented could also be used to evaluate variable effects with increased confidence and tolerance optimization.

  8. Self-Shielded Flux Cored Wire Evaluation

    DTIC Science & Technology

    1980-12-01

    5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) Naval Surface Warfare Center CD Code 2230 - Design Integration Tools Building...ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release...tensile and yield strength, percent elongation, and percent reduction of area reported. This testing was performed with a Satec 400 WHVP tensile

  9. PSE Aysis of Crossflow Instability on HifIre-5B Flight Test

    DTIC Science & Technology

    2017-06-05

    AIR FORCE RESEARCH LABORATORY AEROSPACE SYSTEMS DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7542 AIR FORCE MATERIEL COMMAND UNITED...Air Force Research Laboratory, Aerospace Systems Directorate Wright-Patterson Air Force Base, OH 45433-7542 Air Force Materiel Command, United...States Air Force 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING Air Force Research Laboratory Aerospace Systems

  10. A Different Type of Test.

    ERIC Educational Resources Information Center

    Brady, Lisa

    2003-01-01

    Describes a successful random drug-testing program for athletes and students involved in school-sponsored activities at Hunterdon Central Regional High School in Flemington, New Jersey. Urges all high schools to implement a random drug-testing program. (PKP)

  11. POTENTIAL RADIOACTIVE POLLUTANTS RESULTING FROM EXPANDED ENERGY PROGRAMS

    EPA Science Inventory

    An effective environmental monitoring program must have a quality assurance component to assure the production of valid data. Quality assurance has many components: calibration standards, standard reference materials, standard reference methods, interlaboratory comparison studies...

  12. KSC01kodi053

    NASA Image and Video Library

    2001-07-19

    KODIAK ISLAND, Alaska -- A technician performs final testing on Starshine 3 at the Naval Research Laboratory in Washington, D.C., to prepare for the launch of the Kodiak Star at Kodiak Island, Alaska. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  13. KSC01kodi054

    NASA Image and Video Library

    2001-07-19

    KODIAK ISLAND, Alaska -- A technician performs final testing on Starshine 3 at the Naval Research Laboratory in Washington, D.C., to prepare for the launch of the Kodiak Star at Kodiak Island, Alaska. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  14. The ACVD task force on canine atopic dermatitis (XVI): laboratory evaluation of dogs with atopic dermatitis with serum-based "allergy" tests.

    PubMed

    DeBoer, D J; Hillier, A

    2001-09-20

    Serum-based in vitro "allergy tests" are commercially available to veterinarians, and are widely used in diagnostic evaluation of a canine atopic patient. Following initial clinical diagnosis, panels of allergen-specific IgE measurements may be performed in an attempt to identify to which allergens the atopic dog is hypersensitive. Methodology for these tests varies by laboratory; few critical studies have evaluated performance of these tests, and current inter-laboratory standardization and quality control measures are inadequate. Other areas where information is critically limited include the usefulness of these tests in diagnosis of food allergy, the effect of extrinsic factors such as season of the year on results, and the influence of corticosteroid treatment on test results. Allergen-specific IgE serological tests are never completely sensitive, nor completely specific. There is only partial correlation between the serum tests and intradermal testing; however, the significance of discrepant results is unknown and unstudied. Variation in test methodologies along with the absence of universal standardization and reporting procedures have created confusion, varying study results, and an inability to compare between studies performed by different investigators.

  15. Results of 1938 IUFRO Scotch pine provenance test in New York

    Treesearch

    Ernst J. Schreiner; E. W. Littlefield; E. J. Eliason

    1961-01-01

    The International Union of Forest Research Organizations (IUFRO) has sponsored several international provenance tests. This is a report on the practical aspects of an IUFRO provenance test with Scotch pine in New York.

  16. Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses*

    PubMed Central

    Rudnick, Paul A.; Clauser, Karl R.; Kilpatrick, Lisa E.; Tchekhovskoi, Dmitrii V.; Neta, Pedatsur; Blonder, Nikša; Billheimer, Dean D.; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Ham, Amy-Joan L.; Jaffe, Jacob D.; Kinsinger, Christopher R.; Mesri, Mehdi; Neubert, Thomas A.; Schilling, Birgit; Tabb, David L.; Tegeler, Tony J.; Vega-Montoto, Lorenzo; Variyath, Asokan Mulayath; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Paulovich, Amanda G.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Tempst, Paul; Liebler, Daniel C.; Stein, Stephen E.

    2010-01-01

    A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications. PMID:19837981

  17. Evaluation of cross-connected waveguides as transfer standards of transmission at high millimetre-wave frequencies

    NASA Astrophysics Data System (ADS)

    Ridler, Nick; Clarke, Roland; Huang, Hui; Zinal, Sherko

    2016-08-01

    At the present time, transfer and verification standards of transmission coefficient (or, equivalently, transmission loss) are not readily available at high millimetre-wave frequencies (i.e. at frequencies ranging typically from 100 GHz to 300 GHz). In recent years, cross-connected waveguide devices have been proposed to provide calculable standards of transmission loss at these frequencies. This paper investigates the viability of these cross-connected waveguides as transfer standards of transmission for inter-laboratory measurement comparison exercises. This relates to their potential use in activities such as international key comparison exercises and measurement audit programmes. A trial inter-laboratory comparison involving four laboratories using two cross-connected waveguides in the WR-05 waveguide size (covering frequencies from 140 GHz to 220 GHz) is described and includes an analysis of the measurement results obtained during the comparison exercise.

  18. [Inter-laboratory reproducibility of pulsed-field electrophoresis for the study of 12 types of Pseudomonas aeruginosa].

    PubMed

    Foissaud, V; Puyhardy, J M; Chapalain, J C; Salord, H; Depina, J J; Morillon, M; Nicolas, P; Perrier-Gros-Claude, J D

    1999-12-01

    The increasing hospital-to-hospital transmission of multiple drug-resistant bacteria is a major concern for bacteriology laboratories involved in nosocomial infection control. The interlaboratory reproducibility of pulsed-field gel electrophoresis (PFGE) for Pseudomonas aeruginosa typing was evaluated by asking four hospital laboratories (two in Lyon, one in Brest, and one in Marseille) to study 11 P. aeruginosa isolates, some of which were epidemiologically related, and the reference strain ATCC 27853. Two laboratories used the Genepath system, one the Chef DR II, system, and one the Chef Mapper system, Bio-Rad, restriction/Spe I. Profiles were read visually and by computerized comparison of restriction band molecular weights (Taxotron, software, PAD Grimont, Pasteur Institute, Paris, France). These two methods led to similar epidemiological conclusions. However, centralization of the data showed poor center-to-center reproducibility due to inadequate standardization of the procedure.

  19. Inter-laboratory comparisons of short-lived gamma-emitting radionuclides in nuclear reactor water.

    PubMed

    Klemola, S K

    2008-01-01

    Inter-laboratory comparisons of gamma-emitting nuclides in nuclear power plant coolant water have been carried out in Finland since 1994. The reactor water samples are taken and prepared by one of the two nuclear power plants and delivered to the participants. Since all the participants get their sample within just a few hours it has been possible to analyse and compare results of nuclides with half-lives shorter than 1h. The total number of short-lived nuclides is 26. All the main nuclides are regularly identified and the activities have been obtained with reasonable accuracy throughout the years. The overall deviation of the results has decreased in 13 years. The effects of true coincidence summing and discrepancies in nuclear data have been identified as potential sources of remaining discrepancies. All the participants have found this type of comparison very useful.

  20. (60)Co in cast steel matrix: A European interlaboratory comparison for the characterisation of new activity standards for calibration of gamma-ray spectrometers in metallurgy.

    PubMed

    Tzika, Faidra; Burda, Oleksiy; Hult, Mikael; Arnold, Dirk; Marroyo, Belén Caro; Dryák, Pavel; Fazio, Aldo; Ferreux, Laurent; García-Toraño, Eduardo; Javornik, Andrej; Klemola, Seppo; Luca, Aurelian; Moser, Hannah; Nečemer, Marijan; Peyrés, Virginia; Reis, Mario; Silva, Lidia; Šolc, Jaroslav; Svec, Anton; Tyminski, Zbigniew; Vodenik, Branko; Wätjen, Uwe

    2016-08-01

    Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Variances and uncertainties of the sample laboratory-to-laboratory variance (S(L)2) and standard deviation (S(L)) associated with an interlaboratory study.

    PubMed

    McClure, Foster D; Lee, Jung K

    2012-01-01

    The validation process for an analytical method usually employs an interlaboratory study conducted as a balanced completely randomized model involving a specified number of randomly chosen laboratories, each analyzing a specified number of randomly allocated replicates. For such studies, formulas to obtain approximate unbiased estimates of the variance and uncertainty of the sample laboratory-to-laboratory (lab-to-lab) STD (S(L)) have been developed primarily to account for the uncertainty of S(L) when there is a need to develop an uncertainty budget that includes the uncertainty of S(L). For the sake of completeness on this topic, formulas to estimate the variance and uncertainty of the sample lab-to-lab variance (S(L)2) were also developed. In some cases, it was necessary to derive the formulas based on an approximate distribution for S(L)2.

  2. Transfer Standard Uncertainty Can Cause Inconclusive Inter-Laboratory Comparisons

    PubMed Central

    Wright, John; Toman, Blaza; Mickan, Bodo; Wübbeler, Gerd; Bodnar, Olha; Elster, Clemens

    2016-01-01

    Inter-laboratory comparisons use the best available transfer standards to check the participants’ uncertainty analyses, identify underestimated uncertainty claims or unknown measurement biases, and improve the global measurement system. For some measurands, instability of the transfer standard can lead to an inconclusive comparison result. If the transfer standard uncertainty is large relative to a participating laboratory’s uncertainty, the commonly used standardized degree of equivalence ≤ 1 criterion does not always correctly assess whether a participant is working within their uncertainty claims. We show comparison results that demonstrate this issue and propose several criteria for assessing a comparison result as passing, failing, or inconclusive. We investigate the behavior of the standardized degree of equivalence and alternative comparison measures for a range of values of the transfer standard uncertainty relative to the individual laboratory uncertainty values. The proposed alternative criteria successfully discerned between passing, failing, and inconclusive comparison results for the cases we examined. PMID:28090123

  3. Inter-laboratory comparison of multi-locus variable-number tandem repeat analysis (MLVA) for verocytotoxin-producing Escherichia coli O157 to facilitate data sharing.

    PubMed

    Holmes, A; Perry, N; Willshaw, G; Hanson, M; Allison, L

    2015-01-01

    Multi-locus variable number tandem repeat analysis (MLVA) is used in clinical and reference laboratories for subtyping verocytotoxin-producing Escherichia coli O157 (VTEC O157). However, as yet there is no common allelic or profile nomenclature to enable laboratories to easily compare data. In this study, we carried out an inter-laboratory comparison of an eight-loci MLVA scheme using a set of 67 isolates of VTEC O157. We found all but two isolates were identical in profile in the two laboratories, and repeat units were homogeneous in size but some were incomplete. A subset of the isolates (n = 17) were sequenced to determine the actual copy number of representative alleles, thereby enabling alleles to be named according to international consensus guidelines. This work has enabled us to realize the potential of MLVA as a portable, highly discriminatory and convenient subtyping method.

  4. Design and Test of a Transonic Axial Splittered Rotor

    DTIC Science & Technology

    2015-06-15

    AXIAL SPLITTERED ROTOR A new design procedure was developed that uses commercial-off-the-shelf software (MATLAB, SolidWorks, and ANSYS-CFX) for the...geometric rendering and analysis of a transonic axial compressor rotor with splitter blades. Predictive numerical simulations were conducted and...Compressor, Splittered Rotor REPORT DOCUMENTATION PAGE 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 10. SPONSOR/MONITOR’S ACRONYM(S) ARO 8. PERFORMING

  5. Fatigue Prediction Verification of Fiberglass Hulls

    DTIC Science & Technology

    2001-10-01

    UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) United States Naval Academy,Department of Naval Architecture & Ocean Engineering...Annapolis,MD,21402 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11...the relatively low number of cycles-to-failure these speci- mens were more efficiently tested on the Satec 50UD ma- chine. The wet specimens were

  6. Durability and Intelligent Nondestructive Evaluation of Adhesive Composite Joints

    DTIC Science & Technology

    2000-09-22

    PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) 8. PERFORMING ORGANIZATION University of Nebraska-Lincoln, Research Grants REPORTNUMBER & Contracts Office...Lincoln, NE 68588-0430 9. SPONSORING / MONrrORLNG AGENCY NAIME(S) AND ADDRESS( ES ) 10. SPONSORING / MONITORING AGENCY REPORT NUMBER * AFOSR 801 North...An MTS 10 MT load cell was used to measure loads. The tests were performed with a Satec spherical alignment coupling attached to the top grip. Acoustic

  7. Intra- and inter-laboratory validation of a dipstick immunoassay for the detection of tropane alkaloids hyoscyamine and scopolamine in animal feed.

    PubMed

    Mulder, Patrick P J; von Holst, Christoph; Nivarlet, Noan; van Egmond, Hans P

    2014-01-01

    Tropane alkaloids (TAs) are toxic secondary metabolites produced by plants of, inter alia, the genera Datura (thorn apple) and Atropa (deadly nightshade). The most relevant TAs are (-)-L-hyoscyamine and (-)-L-scopolamine, which act as antagonists of acetylcholine muscarinic receptors and can induce a variety of distinct toxic syndromes in mammals (anti-cholinergic poisoning). The European Union has regulated the presence of seeds of Datura sp. in animal feeds, specifying that the content should not exceed 1000 mg kg(-1) (Directive 2002/32/EC). For materials that have not been ground, visual screening methods are often used to comply with these regulations, but these cannot be used for ground materials and compound feeds. Immunological assays, preferably in dipstick format, can be a simple and cost-effective approach to monitor feedstuffs in an HACCP setting in control laboratories. So far no reports have been published on immunoassays that are capable of detecting both hyoscyamine and scopolamine with equal sensitivity and that can be used, preferably in dipstick format, for application as a fast screening tool in feed analysis. This study presents the results obtained for the in-house and inter-laboratory validation of a dipstick immunoassay for the detection of hyoscyamine and scopolamine in animal feed. The target level was set at 800 µg kg(-1) for the sum of both alkaloids. By using a representative set of compound feeds during validation and a robust study design, a reliable impression of the relevant characteristics of the assay could be obtained. The dipstick test displayed similar sensitivity towards the two alkaloids and it could be concluded that the test has a very low probability of producing a false-positive result at blank level or a false-negative result at target level. The assay can be used for monitoring of TAs in feedstuffs, but has also potential as a quick screening tool in food- or feed-related poisonings.

  8. Fishing for teratogens: a consortium effort for a harmonized zebrafish developmental toxicology assay.

    PubMed

    Ball, Jonathan S; Stedman, Donald B; Hillegass, Jedd M; Zhang, Cindy X; Panzica-Kelly, Julie; Coburn, Aleasha; Enright, Brian P; Tornesi, Belen; Amouzadeh, Hamid R; Hetheridge, Malcolm; Gustafson, Anne-Lee; Augustine-Rauch, Karen A

    2014-05-01

    A consortium of biopharmaceutical companies previously developed an optimized Zebrafish developmental toxicity assay (ZEDTA) where chorionated embryos were exposed to non-proprietary test compounds from 5 to 6 h post fertilization and assessed for morphological integrity at 5 days post fertilization. With the original 20 test compounds, this achieved an overall predictive value for teratogenicity of 88% of mammalian in vivo outcome [Gustafson, A. L., Stedman, D. B., Ball, J., Hillegass, J. M., Flood, A., Zhang, C. X., Panzica-Kelly, J., Cao, J., Coburn, A., Enright, B. P., et al. (2012). Interlaboratory assessment of a harmonized Zebrafish developmental toxicology assay-Progress report on phase I. Reprod. Toxicol. 33, 155-164]. In the second phase of this project, 38 proprietary pharmaceutical compounds from four consortium members were evaluated in two laboratories using the optimized method using either pond-derived or cultivated-strain wild-type Zebrafish embryos at concentrations up to 100μM. Embryo uptake of all compounds was assessed using liquid chromatography-tandem mass spectrometry. Twenty eight of 38 compounds had a confirmed embryo uptake of >5%, and with these compounds the ZEDTA achieved an overall predictive value of 82% and 65% at the two respective laboratories. When low-uptake compounds (≤ 5%) were retested with logarithmic concentrations up to 1000μM, the overall predictivity across all 38 compounds was 79% and 62% respectively, with the first laboratory achieving 74% sensitivity (teratogen detection) and 82% specificity (non-teratogen detection) and the second laboratory achieving 63% sensitivity (teratogen detection) and 62% specificity (non-teratogen detection). Subsequent data analyses showed that technical differences rather than strain differences were the primary contributor to interlaboratory differences in predictivity. Based on these results, the ZEDTA harmonized methodology is currently being used for compound assessment at lead optimization stage of development by 4/5 of the consortium companies.

  9. Pre-trial inter-laboratory analytical validation of the FOCUS4 personalised therapy trial.

    PubMed

    Richman, Susan D; Adams, Richard; Quirke, Phil; Butler, Rachel; Hemmings, Gemma; Chambers, Phil; Roberts, Helen; James, Michelle D; Wozniak, Sue; Bathia, Riya; Pugh, Cheryl; Maughan, Timothy; Jasani, Bharat

    2016-01-01

    Molecular characterisation of tumours is increasing personalisation of cancer therapy, tailored to an individual and their cancer. FOCUS4 is a molecularly stratified clinical trial for patients with advanced colorectal cancer. During an initial 16-week period of standard first-line chemotherapy, tumour tissue will undergo several molecular assays, with the results used for cohort allocation, then randomisation. Laboratories in Leeds and Cardiff will perform the molecular testing. The results of a rigorous pre-trial inter-laboratory analytical validation are presented and discussed. Wales Cancer Bank supplied FFPE tumour blocks from 97 mCRC patients with consent for use in further research. Both laboratories processed each sample according to an agreed definitive FOCUS4 laboratory protocol, reporting results directly to the MRC Trial Management Group for independent cross-referencing. Pyrosequencing analysis of mutation status at KRAS codons12/13/61/146, NRAS codons12/13/61, BRAF codon600 and PIK3CA codons542/545/546/1047, generated highly concordant results. Two samples gave discrepant results; in one a PIK3CA mutation was detected only in Leeds, and in the other, a PIK3CA mutation was only detected in Cardiff. pTEN and mismatch repair (MMR) protein expression was assessed by immunohistochemistry (IHC) resulting in 6/97 discordant results for pTEN and 5/388 for MMR, resolved upon joint review. Tumour heterogeneity was likely responsible for pyrosequencing discrepancies. The presence of signet-ring cells, necrosis, mucin, edge-effects and over-counterstaining influenced IHC discrepancies. Pre-trial assay analytical validation is essential to ensure appropriate selection of patients for targeted therapies. This is feasible for both mutation testing and immunohistochemical assays and must be built into the workup of such trials. ISRCTN90061564. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Determination of 238u/235u, 236u/238u and uranium concentration in urine using sf-icp-ms and mc-icp-ms: an interlaboratory comparison.

    PubMed

    Parrish, Randall R; Thirlwall, Matthew F; Pickford, Chris; Horstwood, Matthew; Gerdes, Axel; Anderson, James; Coggon, David

    2006-02-01

    Accidental exposure to depleted or enriched uranium may occur in a variety of circumstances. There is a need to quantify such exposure, with the possibility that the testing may post-date exposure by months or years. Therefore, it is important to develop a very sensitive test to measure precisely the isotopic composition of uranium in urine at low levels of concentration. The results of an interlaboratory comparison using sector field (SF)-inductively coupled plasma-mass spectrometry (ICP-MS) and multiple collector (MC)-ICP-MS for the measurement of uranium concentration and U/U and U/U isotopic ratios of human urine samples are presented. Three urine samples were verified to contain uranium at 1-5 ng L and shown to have natural uranium isotopic composition. Portions of these urine batches were doped with depleted uranium (DU) containing small quantities of U, and the solutions were split into 100 mL and 400 mL aliquots that were subsequently measured blind by three laboratories. All methods investigated were able to measure accurately U/U with precisions of approximately 0.5% to approximately 4%, but only selected MC-ICP-MS methods were capable of consistently analyzing U/U to reasonable precision at the approximately 20 fg L level of U abundance. Isotope dilution using a U tracer demonstrates the ability to measure concentrations to better than +/-4% with the MC-ICP-MS method, though sample heterogeneity in urine samples was shown to be problematic in some cases. MC-ICP-MS outperformed SF-ICP-MS methods, as was expected. The MC-ICP-MS methodology described is capable of measuring to approximately 1% precision the U/U of any sample of human urine over the entire range of uranium abundance down to <1 ng L, and detecting very small amounts of DU contained therein.

  11. Quality assurance and quality control in light stable isotope laboratories: A case study of Rio Grande, Texas, water samples

    USGS Publications Warehouse

    Coplen, T.B.; Qi, H.

    2009-01-01

    New isotope laboratories can achieve the goal of reporting the same isotopic composition within analytical uncertainty for the same material analysed decades apart by (1) writing their own acceptance testing procedures and putting them into their mass spectrometric or laser-based isotope-ratio equipment procurement contract, (2) requiring a manufacturer to demonstrate acceptable performance using all sample ports provided with the instrumentation, (3) for each medium to be analysed, prepare two local reference materials substantially different in isotopic composition to encompass the range in isotopic composition expected in the laboratory and calibrated them with isotopic reference materials available from the International Atomic Energy Agency (IAEA) or the US National Institute of Standards and Technology (NIST), (4) using the optimum storage containers (for water samples, sealing in glass ampoules that are sterilised after sealing is satisfactory), (5) interspersing among sample unknowns local laboratory isotopic reference materials daily (internationally distributed isotopic reference materials can be ordered at three-year intervals, and can be used for elemental analyser analyses and other analyses that consume less than 1 mg of material) - this process applies to H, C, N, O, and S isotope ratios, (6) calculating isotopic compositions of unknowns by normalising isotopic data to that of local reference materials, which have been calibrated to internationally distributed isotopic reference materials, (7) reporting results on scales normalised to internationally distributed isotopic reference materials (where they are available) and providing to sample submitters the isotopic compositions of internationally distributed isotopic reference materials of the same substance had they been analysed with unknowns, (8) providing an audit trail in the laboratory for analytical results - this trail commonly will be in electronic format and might include a laboratory information management system, (9) making at regular intervals a complete backup of laboratory analytical data (both of samples logged into the laboratory and of mass spectrometric analyses), being sure to store one copy of this backup offsite, and (10) participating in interlaboratory comparison exercises sponsored by the IAEA and other agencies at regular intervals. ?? Taylor & Francis.

  12. Producing standard damaged DNA samples by heating: pitfalls and suggestions.

    PubMed

    Fattorini, Paolo; Marrubini, Giorgio; Bonin, Serena; Bertoglio, Barbara; Grignani, Pierangela; Recchia, Elisa; Pitacco, Paola; Procopio, Francesca; Cantoni, Carolina; Pajnič, Irena Zupanič; Sorçaburu-Cigliero, Solange; Previderè, Carlo

    2018-05-15

    Heat-mediated hydrolysis of DNA is a simple and inexpensive method for producing damaged samples in vitro. Despite heat-mediated DNA hydrolysis is being widely used in forensic and clinical validation procedures, the lack of standardized procedures makes it impossible to compare the intra and inter-laboratory outcomes of the damaging treatments. In this work, a systematic approach to heat induced DNA hydrolysis was performed at 70 °C for 0-18 h to test the role both of the hydrolysis buffer and of the experimental conditions. Specifically, a trial DNA sample, resuspended in three different media (ultrapure water, 0.1% DEPC-water and, respectively, TE) was treated both in Eppendorf tubes ("Protocol P") and in Eppendorf tubes provided with screwcaps ("Protocol S"). The results of these comparative tests were assessed by normalization of the qPCR results. DEPC-water increased the degradation of the samples up to about 100 times when compared to the ultrapure water. Conversely, the TE protected the DNA from degradation whose level was about 1700 times lower than in samples treated in ultrapure water. Even the employment of the "Protocol S" affected the level of degradation, by consistently increasing it (up to about 180 times in DEPC-water). Thus, this comparative approach showed that even seemingly apparently trivial and often underestimated parameters modify the degradation level up to 2-3 orders of magnitude. The chemical-physical reasons of these findings are discussed together with the role of potential factors such as enhanced reactivity of CO 2 , ROS, NO x and pressure, which are likely to be involved. Since the intra and inter-laboratory comparison of the outcomes of the hydrolytic procedure is the first step toward its standardization, the normalization of the qPCR data by the UV/qPCR ratio seems to be the simplest and most reliable way to allow this. Finally, the supplying (provided with the commercial qPCR kits) of a DNA sample whose degree of degradation is well documented could be helpful in ISO/IEC 17025 validation procedures and in proficiency testing. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Data processing of qualitative results from an interlaboratory comparison for the detection of “Flavescence dorée” phytoplasma: How the use of statistics can improve the reliability of the method validation process in plant pathology

    PubMed Central

    Renaudin, Isabelle; Poliakoff, Françoise

    2017-01-01

    A working group established in the framework of the EUPHRESCO European collaborative project aimed to compare and validate diagnostic protocols for the detection of “Flavescence dorée” (FD) phytoplasma in grapevines. Seven molecular protocols were compared in an interlaboratory test performance study where each laboratory had to analyze the same panel of samples consisting of DNA extracts prepared by the organizing laboratory. The tested molecular methods consisted of universal and group-specific real-time and end-point nested PCR tests. Different statistical approaches were applied to this collaborative study. Firstly, there was the standard statistical approach consisting in analyzing samples which are known to be positive and samples which are known to be negative and reporting the proportion of false-positive and false-negative results to respectively calculate diagnostic specificity and sensitivity. This approach was supplemented by the calculation of repeatability and reproducibility for qualitative methods based on the notions of accordance and concordance. Other new approaches were also implemented, based, on the one hand, on the probability of detection model, and, on the other hand, on Bayes’ theorem. These various statistical approaches are complementary and give consistent results. Their combination, and in particular, the introduction of new statistical approaches give overall information on the performance and limitations of the different methods, and are particularly useful for selecting the most appropriate detection scheme with regards to the prevalence of the pathogen. Three real-time PCR protocols (methods M4, M5 and M6 respectively developed by Hren (2007), Pelletier (2009) and under patent oligonucleotides) achieved the highest levels of performance for FD phytoplasma detection. This paper also addresses the issue of indeterminate results and the identification of outlier results. The statistical tools presented in this paper and their combination can be applied to many other studies concerning plant pathogens and other disciplines that use qualitative detection methods. PMID:28384335

  14. Data processing of qualitative results from an interlaboratory comparison for the detection of "Flavescence dorée" phytoplasma: How the use of statistics can improve the reliability of the method validation process in plant pathology.

    PubMed

    Chabirand, Aude; Loiseau, Marianne; Renaudin, Isabelle; Poliakoff, Françoise

    2017-01-01

    A working group established in the framework of the EUPHRESCO European collaborative project aimed to compare and validate diagnostic protocols for the detection of "Flavescence dorée" (FD) phytoplasma in grapevines. Seven molecular protocols were compared in an interlaboratory test performance study where each laboratory had to analyze the same panel of samples consisting of DNA extracts prepared by the organizing laboratory. The tested molecular methods consisted of universal and group-specific real-time and end-point nested PCR tests. Different statistical approaches were applied to this collaborative study. Firstly, there was the standard statistical approach consisting in analyzing samples which are known to be positive and samples which are known to be negative and reporting the proportion of false-positive and false-negative results to respectively calculate diagnostic specificity and sensitivity. This approach was supplemented by the calculation of repeatability and reproducibility for qualitative methods based on the notions of accordance and concordance. Other new approaches were also implemented, based, on the one hand, on the probability of detection model, and, on the other hand, on Bayes' theorem. These various statistical approaches are complementary and give consistent results. Their combination, and in particular, the introduction of new statistical approaches give overall information on the performance and limitations of the different methods, and are particularly useful for selecting the most appropriate detection scheme with regards to the prevalence of the pathogen. Three real-time PCR protocols (methods M4, M5 and M6 respectively developed by Hren (2007), Pelletier (2009) and under patent oligonucleotides) achieved the highest levels of performance for FD phytoplasma detection. This paper also addresses the issue of indeterminate results and the identification of outlier results. The statistical tools presented in this paper and their combination can be applied to many other studies concerning plant pathogens and other disciplines that use qualitative detection methods.

  15. Overview of Marshall Space Flight Center Activities for the Combustion Stability Tool Development Program

    NASA Technical Reports Server (NTRS)

    Kenny, R. J.; Greene, W. D.

    2016-01-01

    This presentation covers the overall scope, schedule, and activities associated with the NASA - Marshall Space Flight Center (MSFC) involvement with the Combustion Stability Tool Development (CSTD) program. The CSTD program is funded by the Air Force Space & Missile Systems Center; it is approximately two years in duration and; and it is sponsoring MSFC to: design, fabricate, & execute multi-element hardware testing, support Air Force Research Laboratory (AFRL) single element testing, and execute testing of a small-scale, multi-element combustion chamber. Specific MSFC Engineering Directorate involvement, per CSTD-sponsored task, will be outlined. This presentation serves a primer for the corresponding works that provide details of the technical work performed by individual groups within MSFC.

  16. Interlaboratory comparison of δ13C and δD measurements of atmospheric CH4 for combined use of data sets from different laboratories

    NASA Astrophysics Data System (ADS)

    Umezawa, Taku; Brenninkmeijer, Carl A. M.; Röckmann, Thomas; van der Veen, Carina; Tyler, Stanley C.; Fujita, Ryo; Morimoto, Shinji; Aoki, Shuji; Sowers, Todd; Schmitt, Jochen; Bock, Michael; Beck, Jonas; Fischer, Hubertus; Michel, Sylvia E.; Vaughn, Bruce H.; Miller, John B.; White, James W. C.; Brailsford, Gordon; Schaefer, Hinrich; Sperlich, Peter; Brand, Willi A.; Rothe, Michael; Blunier, Thomas; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.; Rice, Andrew L.; Bergamaschi, Peter; Veidt, Cordelia; Levin, Ingeborg

    2018-03-01

    We report results from a worldwide interlaboratory comparison of samples among laboratories that measure (or measured) stable carbon and hydrogen isotope ratios of atmospheric CH4 (δ13C-CH4 and δD-CH4). The offsets among the laboratories are larger than the measurement reproducibility of individual laboratories. To disentangle plausible measurement offsets, we evaluated and critically assessed a large number of intercomparison results, some of which have been documented previously in the literature. The results indicate significant offsets of δ13C-CH4 and δD-CH4 measurements among data sets reported from different laboratories; the differences among laboratories at modern atmospheric CH4 level spread over ranges of 0.5 ‰ for δ13C-CH4 and 13 ‰ for δD-CH4. The intercomparison results summarized in this study may be of help in future attempts to harmonize δ13C-CH4 and δD-CH4 data sets from different laboratories in order to jointly incorporate them into modelling studies. However, establishing a merged data set, which includes δ13C-CH4 and δD-CH4 data from multiple laboratories with desirable compatibility, is still challenging due to differences among laboratories in instrument settings, correction methods, traceability to reference materials and long-term data management. Further efforts are needed to identify causes of the interlaboratory measurement offsets and to decrease those to move towards the best use of available δ13C-CH4 and δD-CH4 data sets.

  17. Multicenter Evaluation of Epidemiological Typing of Methicillin-Resistant Staphylococcus aureus Strains by Repetitive-Element PCR Analysis

    PubMed Central

    Deplano, Ariane; Schuermans, Annette; Van Eldere, Johan; Witte, Wolfgang; Meugnier, Hèléne; Etienne, Jerome; Grundmann, Hajo; Jonas, Daniel; Noordhoek, Gerda T.; Dijkstra, Jolanda; van Belkum, Alex; van Leeuwen, Willem; Tassios, Panayotis T.; Legakis, Nicholas J.; van der Zee, Anneke; Bergmans, Anneke; Blanc, Dominique S.; Tenover, Fred C.; Cookson, Barry C.; O'Neil, Gael; Struelens, Marc J.

    2000-01-01

    Rapid and efficient epidemiologic typing systems would be useful to monitor transmission of methicillin-resistant Staphylococcus aureus (MRSA) at both local and interregional levels. To evaluate the intralaboratory performance and interlaboratory reproducibility of three recently developed repeat-element PCR (rep-PCR) methods for the typing of MRSA, 50 MRSA strains characterized by pulsed-field gel electrophoresis (PFGE) (SmaI) analysis and epidemiological data were blindly typed by inter-IS256, 16S-23S ribosomal DNA (rDNA), and MP3 PCR in 12 laboratories in eight countries using standard reagents and protocols. Performance of typing was defined by reproducibility (R), discriminatory power (D), and agreement with PFGE analysis. Interlaboratory reproducibility of pattern and type classification was assessed visually and using gel analysis software. Each typing method showed a different performance level in each center. In the center performing best with each method, inter-IS256 PCR typing achieved R = 100% and D = 100%; 16S-23S rDNA PCR, R = 100% and D = 82%; and MP3 PCR, R = 80% and D = 83%. Concordance between rep-PCR type and PFGE type ranged by center: 70 to 90% for inter-IS256 PCR, 44 to 57% for 16S-23S rDNA PCR, and 53 to 54% for MP3 PCR analysis. In conclusion, the performance of inter-IS256 PCR typing was similar to that of PFGE analysis in some but not all centers, whereas other rep-PCR protocols showed lower discrimination and intralaboratory reproducibility. None of these assays, however, was sufficiently reproducible for interlaboratory exchange of data. PMID:11015358

  18. Acute toxicity of diazinon is similar for eight stocks of bobwhite

    USGS Publications Warehouse

    Hill, E.F.; Camardese, M.B.; Heinz, G.H.; Spann, J.W.; DeBevec, A.B.

    1984-01-01

    Nine-week-old bobwhite (Colinus virginianus) from eight different game farms were tested for their sensitivity to an acute oral exposure of technical-grade diazinon (phosphorothioic acid O, O-diethyl-O-[6-methyl- 2-(1 -methylethy 1)-4-pyrimidinyl]ester). Extraneous variables associated with interlaboratory differences in husbandry were eliminated by incubating eggs and rearing chicks to test age for all stocks simultaneously in the same facilities at the Patuxent Wildlife Research Center. Under this single set of conditions, the responses of the eight stocks of bobwhite to diazinon were statistically inseparable, with LD50 values varying from 13 mg/kg (95% confidence interval, 8-21 mg/kg) to 17 mg/kg (95% confidence interval, 11-25 mg/kg). The pooled LD50 for the eight stocks was 14.7 mg/kg (95% confidence interval,13.1-16.5 mg/kg).

  19. An inter- laboratory proficiency testing exercise for rabies diagnosis in Latin America and the Caribbean

    PubMed Central

    Clavijo, Alfonso; Freire de Carvalho, Mary H.; Orciari, Lillian A.; Velasco-Villa, Andres; Ellison, James A.; Greenberg, Lauren; Yager, Pamela A.; Green, Douglas B.; Vigilato, Marco A.; Cosivi, Ottorino; Del Rio-Vilas, Victor J.

    2017-01-01

    The direct fluorescent antibody test (DFA), is performed in all rabies reference laboratories across Latin America and the Caribbean (LAC). Despite DFA being a critical capacity in the control of rabies, there is not a standardized protocol in the region. We describe the results of the first inter-laboratory proficiency exercise of national rabies laboratories in LAC countries as part of the regional efforts towards dog-maintained rabies elimination in the American region. Twenty three laboratories affiliated to the Ministries of Health and Ministries of Agriculture participated in this exercise. In addition, the laboratories completed an online questionnaire to assess laboratory practices. Answers to the online questionnaire indicated large variability in the laboratories throughput, equipment used, protocols availability, quality control standards and biosafety requirements. Our results will inform actions to improve and harmonize laboratory rabies capacities across LAC in support for the regional efforts towards elimination of dog-maintained rabies. PMID:28369139

  20. Second NBL measurement evaluation program meeting: A summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spaletto, M.I.; Clapper, M.; Tolbert, M.E.M.

    New Brunswick Laboratory (NBL), the US government`s nuclear materials measurements and reference materials laboratory, administers interlaboratory measurement evaluation programs to evaluate the quality and adequacy of safeguards measurements. The NBL Measurement Evaluation Program covers several types of safeguards analytical measurements. The Safeguards Measurement Evaluation (SME) program distributes test materials destructive measurements of uranium for both elemental concentration and isotopic abundances, and of plutonium for isotopic abundances. The Calorimetry Exchange (CalEx) Program tests the quality of nondestructive measurements of plutonium isotopic abundances by gamma spectroscopy and plutonium concentration by calorimetry. In May 1997, more than 30 representatives from the Department ofmore » Energy (DOE), its contractor laboratories, and Nuclear Regulatory Commission licensees met at NBL in Argonne, Illinois, for the annual meeting of the Measurement Evaluation Program. The summary which follows details key points that were discussed or presented at the meeting.« less

  1. Towards a standardization of biomethane potential tests.

    PubMed

    Holliger, Christof; Alves, Madalena; Andrade, Diana; Angelidaki, Irini; Astals, Sergi; Baier, Urs; Bougrier, Claire; Buffière, Pierre; Carballa, Marta; de Wilde, Vinnie; Ebertseder, Florian; Fernández, Belén; Ficara, Elena; Fotidis, Ioannis; Frigon, Jean-Claude; de Laclos, Hélène Fruteau; Ghasimi, Dara S M; Hack, Gabrielle; Hartel, Mathias; Heerenklage, Joern; Horvath, Ilona Sarvari; Jenicek, Pavel; Koch, Konrad; Krautwald, Judith; Lizasoain, Javier; Liu, Jing; Mosberger, Lona; Nistor, Mihaela; Oechsner, Hans; Oliveira, João Vítor; Paterson, Mark; Pauss, André; Pommier, Sébastien; Porqueddu, Isabella; Raposo, Francisco; Ribeiro, Thierry; Rüsch Pfund, Florian; Strömberg, Sten; Torrijos, Michel; van Eekert, Miriam; van Lier, Jules; Wedwitschka, Harald; Wierinck, Isabella

    2016-12-01

    Production of biogas from different organic materials is a most interesting source of renewable energy. The biomethane potential (BMP) of these materials has to be determined to get insight in design parameters for anaerobic digesters. Although several norms and guidelines for BMP tests exist, inter-laboratory tests regularly show high variability of BMPs for the same substrate. A workshop was held in June 2015, in Leysin, Switzerland, with over 40 attendees from 30 laboratories around the world, to agree on common solutions to the conundrum of inconsistent BMP test results. This paper presents the consensus of the intense roundtable discussions and cross-comparison of methodologies used in respective laboratories. Compulsory elements for the validation of BMP results were defined. They include the minimal number of replicates, the request to carry out blank and positive control assays, a criterion for the test duration, details on BMP calculation, and last but not least criteria for rejection of the BMP tests. Finally, recommendations on items that strongly influence the outcome of BMP tests such as inoculum characteristics, substrate preparation, test setup, and data analysis are presented to increase the probability of obtaining validated and reproducible results.

  2. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    PubMed Central

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  3. Sample selection, preparation methods, and the apparent tensile properties of silkworm (B. mori) cocoon silk.

    PubMed

    Reed, Emily J; Bianchini, Lindsay L; Viney, Christopher

    2012-06-01

    Reported literature values of the tensile properties of natural silk cover a wide range. While much of this inconsistency is the result of variability that is intrinsic to silk, some is also a consequence of differences in the way that silk is prepared for tensile tests. Here we explore how measured mechanical properties of Bombyx mori cocoon silk are affected by two intrinsic factors (the location from which the silk is collected within the cocoon, and the color of the silk), and two extrinsic factors (the storage conditions prior to testing, and different styles of reeling the fiber). We find that extrinsic and therefore controllable factors can affect the properties more than the intrinsic ones studied. Our results suggest that enhanced inter-laboratory collaborations, that lead to standardized sample collection, handling, and storage protocols prior to mechanical testing, would help to decrease unnecessary (and complicating) variation in reported tensile properties. Copyright © 2011 Wiley Periodicals, Inc.

  4. Inter-laboratory assessment of a harmonized zebrafish developmental toxicology assay - progress report on phase I.

    PubMed

    Gustafson, A-L; Stedman, D B; Ball, J; Hillegass, J M; Flood, A; Zhang, C X; Panzica-Kelly, J; Cao, J; Coburn, A; Enright, B P; Tornesi, M B; Hetheridge, M; Augustine-Rauch, K A

    2012-04-01

    This report provides a progress update of a consortium effort to develop a harmonized zebrafish developmental toxicity assay. Twenty non-proprietary compounds (10 animal teratogens and 10 animal non-teratogens) were evaluated blinded in 4 laboratories. Zebrafish embryos from pond-derived and cultivated strain wild types were exposed to the test compounds for 5 days and subsequently evaluated for lethality and morphological changes. Each of the testing laboratories achieved similar overall concordance to the animal data (60-70%). Subsequent optimization procedures to improve the overall concordance focused on compound formulation and test concentration adjustments, chorion permeation and number of replicates. These optimized procedures were integrated into a revised protocol and all compounds were retested in one lab using embryos from pond-derived zebrafish and achieved 85% total concordance. To further assess assay performance, a study of additional compounds is currently in progress at two laboratories using embryos from pond-derived and cultivated-strain wild type zebrafish. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. The Case for Laboratory Developed Procedures

    PubMed Central

    Sabatini, Linda M.; Tsongalis, Gregory J.; Caliendo, Angela M.; Olsen, Randall J.; Ashwood, Edward R.; Bale, Sherri; Benirschke, Robert; Carlow, Dean; Funke, Birgit H.; Grody, Wayne W.; Hayden, Randall T.; Hegde, Madhuri; Lyon, Elaine; Pessin, Melissa; Press, Richard D.; Thomson, Richard B.

    2017-01-01

    An explosion of knowledge and technology is revolutionizing medicine and patient care. Novel testing must be brought to the clinic with safety and accuracy, but also in a timely and cost-effective manner, so that patients can benefit and laboratories can offer testing consistent with current guidelines. Under the oversight provided by the Clinical Laboratory Improvement Amendments, laboratories have been able to develop and optimize laboratory procedures for use in-house. Quality improvement programs, interlaboratory comparisons, and the ability of laboratories to adjust assays as needed to improve results, utilize new sample types, or incorporate new mutations, information, or technologies are positive aspects of Clinical Laboratory Improvement Amendments oversight of laboratory-developed procedures. Laboratories have a long history of successful service to patients operating under Clinical Laboratory Improvement Amendments. A series of detailed clinical examples illustrating the quality and positive impact of laboratory-developed procedures on patient care is provided. These examples also demonstrate how Clinical Laboratory Improvement Amendments oversight ensures accurate, reliable, and reproducible testing in clinical laboratories. PMID:28815200

  6. Detection of QT prolongation using a novel electrocardiographic analysis algorithm applying intelligent automation: prospective blinded evaluation using the Cardiac Safety Research Consortium electrocardiographic database.

    PubMed

    Green, Cynthia L; Kligfield, Paul; George, Samuel; Gussak, Ihor; Vajdic, Branislav; Sager, Philip; Krucoff, Mitchell W

    2012-03-01

    The Cardiac Safety Research Consortium (CSRC) provides both "learning" and blinded "testing" digital electrocardiographic (ECG) data sets from thorough QT (TQT) studies annotated for submission to the US Food and Drug Administration (FDA) to developers of ECG analysis technologies. This article reports the first results from a blinded testing data set that examines developer reanalysis of original sponsor-reported core laboratory data. A total of 11,925 anonymized ECGs including both moxifloxacin and placebo arms of a parallel-group TQT in 181 subjects were blindly analyzed using a novel ECG analysis algorithm applying intelligent automation. Developer-measured ECG intervals were submitted to CSRC for unblinding, temporal reconstruction of the TQT exposures, and statistical comparison to core laboratory findings previously submitted to FDA by the pharmaceutical sponsor. Primary comparisons included baseline-adjusted interval measurements, baseline- and placebo-adjusted moxifloxacin QTcF changes (ddQTcF), and associated variability measures. Developer and sponsor-reported baseline-adjusted data were similar with average differences <1 ms for all intervals. Both developer- and sponsor-reported data demonstrated assay sensitivity with similar ddQTcF changes. Average within-subject SD for triplicate QTcF measurements was significantly lower for developer- than sponsor-reported data (5.4 and 7.2 ms, respectively; P < .001). The virtually automated ECG algorithm used for this analysis produced similar yet less variable TQT results compared with the sponsor-reported study, without the use of a manual core laboratory. These findings indicate that CSRC ECG data sets can be useful for evaluating novel methods and algorithms for determining drug-induced QT/QTc prolongation. Although the results should not constitute endorsement of specific algorithms by either CSRC or FDA, the value of a public domain digital ECG warehouse to provide prospective, blinded comparisons of ECG technologies applied for QT/QTc measurement is illustrated. Copyright © 2012 Mosby, Inc. All rights reserved.

  7. Extrudable Gel-Forming Bioabsorbable Hemostatic Tissue Adhesives for Traumatic and Burn Wounds

    DTIC Science & Technology

    1996-12-01

    DAMD17-96-1-6241 6. AUTHOR(S) Shalaby W. Shalaby, Ph.D. 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) B. PERFORMING ORGANIZATION Poly-Med...Incorporated REPORT NUMBER Anderson, South Carolina 29625 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSORING/MONITORING Commander AGENCY...the wound breaking strength. This was done using a Satec universal testing machine. Details of the animal protocol are given in Appendix A. The

  8. Structural Performance of Aluminum and Stainless Steel Pyramidal Truss Core Sandwich Panels

    DTIC Science & Technology

    2009-07-01

    PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) U.S. Army Research Laboratory ATTN: RDRL-WMM-D Aberdeen Proving Ground, MD 21005-5069 8. PERFORMING...ORGANIZATION REPORT NUMBER ARL-TR-4867 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSOR/MONITOR’S ACRONYM(S) 11...Instron- Satec 4-post hydraulic test frame, with a capacity of 1 million lb. The samples were sandwiched between hardened end plates to protect the

  9. Whole Exome Analysis of Early Onset Alzheimer’s Disease

    DTIC Science & Technology

    2017-04-01

    manufacturer’s protocol at the HIHG Center for Genome Technology. After capture, the DNA was tested for uniform enrichment of targets via quantitative PCR...CONTRACTING ORGANIZATION: University of Miami Miami, FL 33136 REPORT DATE: April 2017 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research ...U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER

  10. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    PubMed

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  11. The role of corruption and unethical behaviour in precluding the placement of industry sponsored clinical trials in sub-Saharan Africa: Stakeholder views.

    PubMed

    Egharevba, Efe; Atkinson, Jacqueline

    2016-08-15

    Clinical trials still represent the gold standard in testing the safety and efficacy of new and existing treatments. However, developing regions including sub-Saharan Africa remain underrepresented in pharmaceutical industry sponsored trials for a number of reasons including fear of corruption and unethical behaviour. This fear exists both on the part of pharmaceutical companies, and investigators carrying out research in the region. The objective of this research was to understand the ethical considerations associated with the conduct of pharmaceutical industry sponsored clinical trials in sub-Saharan Africa. Corruption was identified as a significant issue by a number of stakeholders who participated in semi-structured interviews and completed questionnaires. Additionally, fear of being perceived as corrupt or unethical even when conducting ethically sound research was raised as a concern. Thus corruption, whether actual or perceived, is one of a number of issues which have precluded the placement of a greater number of pharmaceutical sponsored clinical trials in this region. More discussion around corruption with all relevant stakeholders is required in order for progress to be made and to enable greater involvement of sub-Saharan African countries in the conduct of industry sponsored clinical trials.

  12. A Retrospective Performance Assessment of the Developmental Neurotoxicity Study in Support of OECD Test Guideline 426

    PubMed Central

    Makris, Susan L.; Raffaele, Kathleen; Allen, Sandra; Bowers, Wayne J.; Hass, Ulla; Alleva, Enrico; Calamandrei, Gemma; Sheets, Larry; Amcoff, Patric; Delrue, Nathalie; Crofton, Kevin M.

    2009-01-01

    Objective We conducted a review of the history and performance of developmental neurotoxicity (DNT) testing in support of the finalization and implementation of Organisation of Economic Co-operation and Development (OECD) DNT test guideline 426 (TG 426). Information sources and analysis In this review we summarize extensive scientific efforts that form the foundation for this testing paradigm, including basic neurotoxicology research, interlaboratory collaborative studies, expert workshops, and validation studies, and we address the relevance, applicability, and use of the DNT study in risk assessment. Conclusions The OECD DNT guideline represents the best available science for assessing the potential for DNT in human health risk assessment, and data generated with this protocol are relevant and reliable for the assessment of these end points. The test methods used have been subjected to an extensive history of international validation, peer review, and evaluation, which is contained in the public record. The reproducibility, reliability, and sensitivity of these methods have been demonstrated, using a wide variety of test substances, in accordance with OECD guidance on the validation and international acceptance of new or updated test methods for hazard characterization. Multiple independent, expert scientific peer reviews affirm these conclusions. PMID:19165382

  13. Note: CO₂-mineral dissolution experiments using a rocking autoclave and a novel titanium reaction cell.

    PubMed

    Purser, Gemma; Rochelle, Christopher A; Wallis, Humphrey C; Rosenqvist, Jörgen; Kilpatrick, Andrew D; Yardley, Bruce W D

    2014-08-01

    A novel titanium reaction cell has been constructed for the study of water-rock-CO2 reactions. The reaction cell has been used within a direct-sampling rocking autoclave and offers certain advantages over traditional "flexible gold/titanium cell" approaches. The main advantage is robustness, as flexible cells are prone to rupture on depressurisation during gas-rich experiments. The reaction cell was tested in experiments during an inter-laboratory comparison study, in which mineral kinetic data were determined. The cell performed well during experiments up to 130 °C and 300 bars pressure. The data obtained were similar to those of other laboratories participating in the study, and also to previously published data.

  14. Spectroradiometer Intercomparison and Impact on Characterizing Photovoltaic Device Performance: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Habte, A.; Andreas, A.; Ottoson, L.

    2014-11-01

    Indoor and outdoor testing of photovoltaic (PV) device performance requires the use of solar simulators and natural solar radiation, respectively. This performance characterization requires accurate knowledge of spectral irradiance distribution that is incident on the devices. Spectroradiometers are used to measure the spectral distribution of solar simulators and solar radiation. On September 17, 2013, a global spectral irradiance intercomparison using spectroradiometers was organized by the Solar Radiation Research Laboratory (SRRL) at the National Renewable Energy Laboratory (NREL). This paper presents highlights of the results of this first intercomparison, which will help to decrease systematic inter-laboratory differences in the measurements ofmore » the outputs or efficiencies of PV devices and harmonize laboratory experimental procedures.« less

  15. Reproducibility experiments on measuring acoustical properties of rigid-frame porous media (round-robin tests).

    PubMed

    Horoshenkov, Kirill V; Khan, Amir; Bécot, François-Xavier; Jaouen, Luc; Sgard, Franck; Renault, Amélie; Amirouche, Nesrine; Pompoli, Francesco; Prodi, Nicola; Bonfiglio, Paolo; Pispola, Giulio; Asdrubali, Francesco; Hübelt, Jörn; Atalla, Noureddine; Amédin, Celse K; Lauriks, Walter; Boeckx, Laurens

    2007-07-01

    This paper reports the results of reproducibility experiments on the interlaboratory characterization of the acoustical properties of three types of consolidated porous media: granulated porous rubber, reticulated foam, and fiberglass. The measurements are conducted in several independent laboratories in Europe and North America. The studied acoustical characteristics are the surface complex acoustic impedance at normal incidence and plane wave absorption coefficient which are determined using the standard impedance tube method. The paper provides detailed procedures related to sample preparation and installation and it discusses the dispersion in the acoustical material property observed between individual material samples and laboratories. The importance of the boundary conditions, homogeneity of the porous material structure, and stability of the adopted signal processing method are highlighted.

  16. An interlaboratory comparison of nanosilver characterisation and hazard identification: Harmonising techniques for high quality data.

    PubMed

    Jemec, Anita; Kahru, Anne; Potthoff, Annegret; Drobne, Damjana; Heinlaan, Margit; Böhme, Steffi; Geppert, Mark; Novak, Sara; Schirmer, Kristin; Rekulapally, Rohit; Singh, Shashi; Aruoja, Villem; Sihtmäe, Mariliis; Juganson, Katre; Käkinen, Aleksandr; Kühnel, Dana

    2016-02-01

    Within the FP7 EU project NanoValid a consortium of six partners jointly investigated the hazard of silver nanoparticles (AgNPs) paying special attention to methodical aspects that are important for providing high-quality ecotoxicity data. Laboratories were supplied with the same original stock dispersion of AgNPs. All partners applied a harmonised procedure for storage and preparation of toxicity test suspensions. Altogether ten different toxicity assays with a range of environmentally relevant test species from different trophic levels were conducted in parallel to AgNP characterisation in the respective test media. The paper presents a comprehensive dataset of toxicity values and AgNP characteristics like hydrodynamic sizes of AgNP agglomerates and the share (%) of Ag(+)-species (the concentration of Ag(+)-species in relation to the total measured concentration of Ag). The studied AgNP preparation (20.4±6.8 nm primary size, mean total Ag concentration 41.14 mg/L, 46-68% of soluble Ag(+)-species in stock, 123.8±12.2 nm mean z-average value in dH2O) showed extreme toxicity to crustaceans Daphnia magna, algae Pseudokirchneriella subcapitata and zebrafish Danio rerio embryos (EC50<0.01 mg total Ag/L), was very toxic in the in vitro assay with rainbow trout Oncorhynchus mykiss gut cells (EC50: 0.01-1 mg total Ag/L); toxic to bacteria Vibrio fischeri, protozoa Tetrahymena thermophila (EC50: 1-10 mg total Ag/L) and harmful to marine crustaceans Artemia franciscana (EC50: 10-100 mg total Ag/L). Along with AgNPs, also the toxicity of AgNO3 was analyzed. The toxicity data revealed the same hazard ranking for AgNPs and AgNO3 (i.e. the EC50 values were in the same order of magnitude) proving the importance of soluble Ag(+)-species analysis for predicting the hazard of AgNPs. The study clearly points to the need for harmonised procedures for the characterisation of NMs. Harmonised procedures should consider: (i) measuring the AgNP properties like hydrodynamic size and metal ions species in each toxicity test medium at a range of concentrations, and (ii) including soluble metal salt control both in toxicity testing as well as in Ag(+)-species measurements. The present study is among the first nanomaterial interlaboratory comparison studies with the aim to improve the hazard identification testing protocols. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Genesis field operational test : final evaluation report

    DOT National Transportation Integrated Search

    1997-09-01

    This document is the Final Evaluation Report for the Genesis Advanced Traveler Information System (ATIS) Field Operational Test (FOT). Genesis was one of the early projects sponsored by the US Department of Transportation (USDOT) Intelligent Transpor...

  18. Redding Responder Field Test - UTC

    DOT National Transportation Integrated Search

    2008-10-30

    This UTC project facilitated field testing and evaluation of the "Responder" system between Phases 1 and 2 of the Redding Responder Project, sponsored by the California Department of Transportation. A pilot system, with hardware purchased by Caltrans...

  19. 40 CFR 792.15 - Inspection of a testing facility.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) EPA will not consider reliable for purposes of showing that a chemical substance or mixture does not... be considered reliable does not, however, relieve the sponsor of a required test of any obligation...

  20. A Profilometry-Based Dentifrice Abrasion Method for V8 Brushing Machines Part III: Multi-Laboratory Validation Testing of RDA-PE.

    PubMed

    Schneiderman, Eva; Colón, Ellen L; White, Donald J; Schemehorn, Bruce; Ganovsky, Tara; Haider, Amir; Garcia-Godoy, Franklin; Morrow, Brian R; Srimaneepong, Viritpon; Chumprasert, Sujin

    2017-09-01

    We have previously reported on progress toward the refinement of profilometry-based abrasivity testing of dentifrices using a V8 brushing machine and tactile or optical measurement of dentin wear. The general application of this technique may be advanced by demonstration of successful inter-laboratory confirmation of the method. The objective of this study was to explore the capability of different laboratories in the assessment of dentifrice abrasivity using a profilometry-based evaluation technique developed in our Mason laboratories. In addition, we wanted to assess the interchangeability of human and bovine specimens. Participating laboratories were instructed in methods associated with Radioactive Dentin Abrasivity-Profilometry Equivalent (RDA-PE) evaluation, including site visits to discuss critical elements of specimen preparation, masking, profilometry scanning, and procedures. Laboratories were likewise instructed on the requirement for demonstration of proportional linearity as a key condition for validation of the technique. Laboratories were provided with four test dentifrices, blinded for testing, with a broad range of abrasivity. In each laboratory, a calibration curve was developed for varying V8 brushing strokes (0, 4,000, and 10,000 strokes) with the ISO abrasive standard. Proportional linearity was determined as the ratio of standard abrasion mean depths created with 4,000 and 10,000 strokes (2.5 fold differences). Criteria for successful calibration within the method (established in our Mason laboratory) was set at proportional linearity = 2.5 ± 0.3. RDA-PE was compared to Radiotracer RDA for the four test dentifrices, with the latter obtained by averages from three independent Radiotracer RDA sites. Individual laboratories and their results were compared by 1) proportional linearity and 2) acquired RDA-PE values for test pastes. Five sites participated in the study. One site did not pass proportional linearity objectives. Data for this site are not reported at the request of the researchers. Three of the remaining four sites reported herein tested human dentin and all three met proportional linearity objectives for human dentin. Three of four sites participated in testing bovine dentin and all three met the proportional linearity objectives for bovine dentin. RDA-PE values for test dentifrices were similar between sites. All four sites that met proportional linearity requirement successfully identified the dentifrice formulated above the industry standard 250 RDA (as RDA-PE). The profilometry method showed at least as good reproducibility and differentiation as Radiotracer assessments. It was demonstrated that human and bovine specimens could be used interchangeably. The standardized RDA-PE method was reproduced in multiple laboratories in this inter-laboratory study. Evidence supports that this method is a suitable technique for ISO method 11609 Annex B.

  1. SERDP AND NRMRL SPONSOR FIELD TEST OF COSOLVENT-ENHANCED DNAPL REMOVAL

    EPA Science Inventory

    A field test of multicomponent cosolvent flooding for in-situ remediation of DNAPL source zones was conducted at the Dover National Test Site (DNTS) at Dover Air Force Base, Delaware, in July, 2001. The test was part of an Enhanced Source Removal (ESR) demonstration project fund...

  2. 40 CFR 792.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test, control, and reference substance... shall be determined by the testing facility or the sponsor before the experimental start date. The stability of the test, control or reference substance shall be determined before the experimental start date...

  3. The Current Often Implemented Fitness Tests in Physical Education Programs: Problems and Future Directions

    ERIC Educational Resources Information Center

    Keating, Xiaofen Deng

    2003-01-01

    This paper aims to examine current nationwide youth fitness test programs, address problems embedded in the programs, and possible solutions. The current Fitnessgram, President's Challenge, and YMCA youth fitness test programs were selected to represent nationwide youth fitness test programs. Sponsors of the nationwide youth fitness test programs…

  4. Extrudable Gel-Forming Bioabsorbable Hemostatic Tissue Adhesives for Traumatic and Burn Wounds

    DTIC Science & Technology

    1997-07-01

    and Bum Wounds DAMD17-96-1-6241 6. AUTHOR(S) Shalaby, Shalaby W., Ph.D. 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) S. PERFORMING ORGANIZATION...REPORT NUMBER Poly-Med, Incorporated Anderson, South Carolina 29625 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS( ES ) 10.SPONSORING I...five test strips as shown in Figure 1, and the dimensions of each sample was measured. The healed incision strength was measured using a Satec T10000

  5. In Vivo Testing of Chemopreventive Agents Using the Dog Model of Spontaneous Prostate Carcinogenesis

    DTIC Science & Technology

    2003-03-01

    Carcinogenesis 6. AUTHOR(S) David J. Waters, Ph.D., DVM 7. PERFORMING ORGANIZATION NAME (S) AND ADDRESS(ES) S. PERFORMING ORGANIZATION Purdue Research...Foundation REPORT NUMBER West Lafayette, IN 47907-1021 E-Mail: waters@vet .purdue .edu 9. SPONSORING / MONITORING 10. SPONSORING I MONITORING AGENCY NAME (S...commercial organizations and trade names in this report do not constitute an official Department of Army endorsement or approval of the products or services

  6. Tools to minimize interlaboratory variability in vitellogenin gene expression monitoring programs

    EPA Science Inventory

    The egg yolk precursor protein vitellogenin is widely used as a biomarker of estrogen exposure in male fish. However, standardized methodology is lacking and little is known regarding the reproducibility of results among laboratories using different equipment, reagents, protocols...

  7. Global Inter-Laboratory Fecal Source Identification Methods Comparison Study

    EPA Science Inventory

    Source tracking is key to identifying sources of fecal contamination for remediation as well as risk assessment. Previous intra- and inter-lab studies have investigated the performance of human and cow-associated source tracking markers, as well as library-dependent fecal source ...

  8. User manual for the NTS ground motion data base retrieval program: ntsgm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    App, F.N.; Tunnell, T.W.

    1994-05-01

    The NTS (Nevada Test Site) Ground Motion Data Base is composed of strong motion data recorded during the normal execution of the US underground test program. It contains surface, subsurface, and structure motion data as digitized waveforms. Currently the data base contains information from 148 underground explosions. This represents about 4,200 measurements and nearly 12,000 individual digitized waveforms. Most of the data was acquired by Los Alamos National Laboratory (LANL) in connection with LANL sponsored underground tests. Some was acquired by Los Alamos on tests conducted by the Defense Nuclear Agency (DNA) and Lawrence Livermore National Laboratory (LLNL), and theremore » are some measurements that were acquired by the other test sponsors on their events and provided for inclusion in this data base. Data acquisition, creation of the data base, and development of the data base retrieval program (ntsgm) are the result of work in support of the Los Alamos Field Test Office and the Office of Nonproliferation and Arms Control.« less

  9. Interlaboratory variability in the quantification of new generation antiepileptic drugs based on external quality assessment data.

    PubMed

    Williams, John; Bialer, Meir; Johannessen, Svein I; Krämer, Günther; Levy, René; Mattson, Richard H; Perucca, Emilio; Patsalos, Philip N; Wilson, John F

    2003-01-01

    To assess interlaboratory variability in the determination of serum levels of new antiepileptic drugs (AEDs). Lyophilised serum samples containing clinically relevant concentrations of felbamate (FBM), gabapentin (GBP), lamotrigine (LTG), the monohydroxy derivative of oxcarbazepine (OCBZ; MHD), tiagabine (TGB), topiramate (TPM), and vigabatrin (VGB) were distributed monthly among 70 laboratories participating in the international Heathcontrol External Quality Assessment Scheme (EQAS). Assay results returned over a 15-month period were evaluated for precision and accuracy. The most frequently measured compound was LTG (65), followed by MHD (39), GBP (19), TPM (18), VGB (15), FBM (16), and TGB (8). High-performance liquid chromatography was the most commonly used assay technique for all drugs except for TPM, for which two thirds of laboratories used a commercial immunoassay. For all assay methods combined, precision was <11% for MHD, FBM, TPM, and LTG, close to 15% for GBP and VGB, and as high as 54% for TGB (p < 0.001). Mean accuracy values were <10% for all drugs other than TGB, for which measured values were on average 13.9% higher than spiked values, with a high variability around the mean (45%). No differences in precision and accuracy were found between methods, except for TPM, for which gas chromatography showed poorer accuracy compared with immunoassay and gas chromatography-mass spectrometry. With the notable exception of TGB, interlaboratory variability in the determination of new AEDs was comparable to that reported with older-generation agents. Poor assay performance is related more to individual operators than to the intrinsic characteristics of the method applied. Participation in an EQAS scheme is recommended to ensure adequate control of assay variability in therapeutic drug monitoring.

  10. Intact cell mass spectrometry (ICMS) used to type methicillin-resistant Staphylococcus aureus: media effects and inter-laboratory reproducibility.

    PubMed

    Walker, J; Fox, A J; Edwards-Jones, V; Gordon, D B

    2002-02-01

    Intact cell mass spectrometry (ICMS) rapidly analyses the surface composition of microorganisms providing rapid, discriminatory fingerprints for identification and subtyping of important nosocomial pathogens such as methicillin resistant Staphylocccus aureus (MRSA). In this study, ICMS using matrix-assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI TOF/MS) was assessed for the identification and subtyping of MRSA. An intra- and inter-laboratory reproducibility study was carried out and the effects of culture media (an important source of variation for ICMS) were also studied. Several media used for the cultural identification of MRSA were examined using a panel of well-characterised staphylococcal isolates (n=26). Six MRSA isolates were analysed over a 1-month period for intra-laboratory reproducibility on the same instrument and three different culture media. Spectra were consistent for each isolate between the four experiments on the same culture medium. Individual isolates produced different spectral profiles on different culture media. Spectra from organisms grown on Columbia blood agar contained more peaks (approximately 120) compared to Columbia agar (approximately 50) and methicillin mannitol salt agar (approximately 25). All 26 staphylococcal isolates were subjected to an inter-laboratory study on two MALDI instruments. For each isolate, the overall spectral profile was the same for each of the two instruments but the baseline threshold values was adjusted due to instrument differences in detector sensitivities. Differences between certain regions of the spectra reproducibly identified isolates belonging to the two major MRSA strains (EMRSA phage group 15 and 16). These results demonstrate ICMS with appropriate media selection is a rapid and reproducible technique for identification and discrimination of MRSA.

  11. Establishment and validation of analytical reference panels for the standardization of quantitative BCR-ABL1 measurements on the international scale.

    PubMed

    White, Helen E; Hedges, John; Bendit, Israel; Branford, Susan; Colomer, Dolors; Hochhaus, Andreas; Hughes, Timothy; Kamel-Reid, Suzanne; Kim, Dong-Wook; Modur, Vijay; Müller, Martin C; Pagnano, Katia B; Pane, Fabrizio; Radich, Jerry; Cross, Nicholas C P; Labourier, Emmanuel

    2013-06-01

    Current guidelines for managing Philadelphia-positive chronic myeloid leukemia include monitoring the expression of the BCR-ABL1 (breakpoint cluster region/c-abl oncogene 1, non-receptor tyrosine kinase) fusion gene by quantitative reverse-transcription PCR (RT-qPCR). Our goal was to establish and validate reference panels to mitigate the interlaboratory imprecision of quantitative BCR-ABL1 measurements and to facilitate global standardization on the international scale (IS). Four-level secondary reference panels were manufactured under controlled and validated processes with synthetic Armored RNA Quant molecules (Asuragen) calibrated to reference standards from the WHO and the NIST. Performance was evaluated in IS reference laboratories and with non-IS-standardized RT-qPCR methods. For most methods, percent ratios for BCR-ABL1 e13a2 and e14a2 relative to ABL1 or BCR were robust at 4 different levels and linear over 3 logarithms, from 10% to 0.01% on the IS. The intraassay and interassay imprecision was <2-fold overall. Performance was stable across 3 consecutive lots, in multiple laboratories, and over a period of 18 months to date. International field trials demonstrated the commutability of the reagents and their accurate alignment to the IS within the intra- and interlaboratory imprecision of IS-standardized methods. The synthetic calibrator panels are robust, reproducibly manufactured, analytically calibrated to the WHO primary standards, and compatible with most BCR-ABL1 RT-qPCR assay designs. The broad availability of secondary reference reagents will further facilitate interlaboratory comparative studies and independent quality assessment programs, which are of paramount importance for worldwide standardization of BCR-ABL1 monitoring results and the optimization of current and new therapeutic approaches for chronic myeloid leukemia. © 2013 American Association for Clinical Chemistry.

  12. Interlaboratory Evaluation of a Multiplexed High Information Content In Vitro Genotoxicity Assay

    PubMed Central

    Bryce, Steven M.; Bernacki, Derek T.; Bemis, Jeffrey C.; Spellman, Richard A.; Engel, Maria E.; Schuler, Maik; Lorge, Elisabeth; Heikkinen, Pekka T.; Hemmann, Ulrike; Thybaud, Véronique; Wilde, Sabrina; Queisser, Nina; Sutter, Andreas; Zeller, Andreas; Guérard, Melanie; Kirkland, David; Dertinger, Stephen D.

    2017-01-01

    We previously described a multiplexed in vitro genotoxicity assay based on flow cytometric analysis of detergent-liberated nuclei that are simultaneously stained with propidium iodide and labeled with fluorescent antibodies against p53, γH2AX, and phospho-histone H3. Inclusion of a known number of microspheres provides absolute nuclei counts. The work described herein was undertaken to evaluate the interlaboratory transferability of this assay, commercially known as MultiFlow™ DNA Damage Kit— p53, γH2AX, Phospho-histone H3. For these experiments seven laboratories studied reference chemicals from a group of 84 representing clastogens, aneugens, and non-genotoxicants. TK6 cells were exposed to chemicals in 96-well plates over a range of concentrations for 24 hrs. At 4 and 24 hrs cell aliquots were added to the MultiFlow reagent mix and following a brief incubation period flow cytometric analysis occurred, in most cases directly from a 96-well plate via a robotic walk-away data acquisition system. Multiplexed response data were evaluated using two analysis approaches, one based on global evaluation factors (i.e., cutoff values derived from all inter-laboratory data), and a second based on multinomial logistic regression that considers multiple biomarkers simultaneously. Both data analysis strategies were devised to categorize chemicals as predominately exhibiting a clastogenic, aneugenic, or non-genotoxic mode of action (MoA). Based on the aggregate 231 experiments that were performed, assay sensitivity, specificity, and concordance in relation to a priori MoA grouping were ≥ 92%. These results are encouraging as they suggest that two distinct data analysis strategies can rapidly and reliably predict new chemicals’ predominant genotoxic MoA based on data from an efficient and transferable multiplexed in vitro assay. PMID:28370322

  13. The CD117 immunohistochemistry tissue microarray survey for quality assurance and interlaboratory comparison: a College of American Pathologists Cell Markers Committee Study.

    PubMed

    Dorfman, David M; Bui, Marilyn M; Tubbs, Raymond R; Hsi, Eric D; Fitzgibbons, Patrick L; Linden, Michael D; Rickert, Robert R; Roche, Patrick C

    2006-06-01

    We have developed tissue microarray-based surveys to allow laboratories to compare their performance in staining predictive immunohistochemical markers, including proto-oncogene CD117 (c-kit), which is characteristically expressed in gastrointestinal stromal tumors (GISTs). GISTs exhibit activating mutations in the c-kit proto-oncogene, which render them amenable to treatment with imatinib mesylate. Consequently, correct identification of c-Kit expression is important for the diagnosis and treatment of GISTs. To analyze CD117 immunohistochemical staining performance by a large number of clinical laboratories. A mechanical device was used to construct tissue microarrays consisting of 3 x 1-mm cores of 10 tumor samples, which can be used to generate hundreds of tissue sections from the arrayed cases, suitable for large-scale interlaboratory comparison of immunohistochemical staining. An initial survey of 63 laboratories and a second survey of 90 laboratories, performed in 2004 and 2005, exhibited >81% concordance for 7 of 10 cores, including all 4 GIST cases, which were immunoreactive for CD117 with >95% staining concordance. Three of the cores achieved less than 81% concordance of results, possibly due to the presence of foci of necrosis in one core and CD117-positive mast cells in 2 cores of CD117-negative neoplasms. There was good performance among a large number of laboratories performing CD117 immunohistochemical staining, with consistently higher concordance of results for CD117-positive GIST cases than for nonimmunoreactive cases. Tissue microarrays for CD117 and other predictive markers should be useful for interlaboratory comparisons, quality assurance, and education of participants regarding staining nuances such as the expression of CKIT by nonneoplastic mast cells.

  14. Quality of pathology reporting is crucial for cancer care and registration: a baseline assessment for breast cancers diagnosed in Belgium in 2008.

    PubMed

    De Schutter, H; Van Damme, N; Colpaert, C; Galant, C; Lambein, K; Cornelis, A; Neven, P; Van Eycken, E

    2015-04-01

    Given the crucial role of pathology reporting in the management of breast cancers, we aimed to investigate the quality and variability of breast cancer pathology reporting in Belgium. Detailed information on non-molecular and molecular parameters was retrieved from the pathology protocols available at the Belgian Cancer Registry for 10,007 breast cancers diagnosed in Belgium in 2008. Substantial underreporting was shown for several clinically relevant non-molecular parameters, such as lymphovascular invasion. High-volume laboratories performed only slightly better than others, and analyses at the individual laboratory level showed clear inter-laboratory variability in reporting for all volume categories. Information on ER/PR and HER2 IHC was mentioned in respectively 91.7% and 90.8% of evaluative cases. HER2 ISH data were available for 78.5% of the cases judged to be 2+ for HER2 IHC. For cases with different specimens analysed, discordance between these specimens was highest for HER2, followed by PR. For HER2, results obtained from different laboratories were even less concordant. In addition, inter-laboratory differences were noted in the used ER/PR scoring systems, the proportion of ER-/PR+ cases, and the relation between histological grade and ER/PR positivity. Data on Ki67 were only available for 43.8% of the investigated cases, and showed inconsistent use of cut-off values. Breast pathology reporting in Belgium in 2008 was suboptimal and showed considerable inter-laboratory variability. Synoptic reporting has been proposed as a facilitator towards increased reporting quality and harmonization, but the lack of aligned informatics remains a major hurdle in its concrete implementation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. C-9 and Other Microgravity Simulations

    NASA Technical Reports Server (NTRS)

    Hecht, Sharon (Editor); Reeves, Jacqueline M. (Editor); Spector, Elisabeth (Editor)

    2009-01-01

    This document represents a summary of medical and scientific evaluations conducted aboard the C-9 and other NASA-sponsored aircraft from June 2008 to June 2009. Included is a general overview of investigations manifested and coordinated by the Human Adaptation and Counter-measures Division. A collection of brief reports that describe tests conducted aboard the NASA-sponsored aircraft follows the overview. Principal investigators and test engineers contributed significantly to the content of the report, describing their particular experiment or hardware evaluation. Although this document follows general guidelines, each report format may vary to accommodate differences in experiment design and procedures. This document concludes with an appendix that provides background information concerning the Reduced Gravity Program. Acknowledgments

  16. C-9 and Other Microgravity Simulations

    NASA Technical Reports Server (NTRS)

    Schlegel, Todd; Skinner, Noel

    2007-01-01

    This document represents a summary of medical and scientific evaluations conducted aboard the C-9 or other NASA-sponsored aircraft from June 30, 2006, to June 30, 2007. Included is a general overview of investigations manifested and coordinated by the Human Adaptation and Countermeasures Office. A collection of brief reports that describe tests conducted aboard the NASA-sponsored aircraft follows the overview. Principal investigators and test engineers contributed significantly to the content of the report, describing their particular experiment or hardware evaluation. Although this document follows general guidelines, each report format may vary to accommodate differences in experiment design and procedures. This document concludes with an appendix that provides background information about the Reduced Gravity Program.

  17. High levels of confusion for cholesterol awareness campaigns.

    PubMed

    Hall, Danika V

    2008-09-15

    Earlier this year, two industry-sponsored advertising campaigns for cholesterol awareness that target the general public were launched in Australia. These campaigns aimed to alert the public to the risks associated with having high cholesterol and encouraged cholesterol testing for wider groups than those specified by the National Heart Foundation. General practitioners should be aware of the potential for the two campaigns to confuse the general public as to who should be tested, and where. The campaign sponsors (Unilever Australasia and Pfizer) each have the potential to benefit by increased market share for their products, and increased profits. These disease awareness campaigns are examples of what is increasingly being termed "condition branding" by pharmaceutical marketing experts.

  18. C-9 and Other Microgravity Simulations Summary Report

    NASA Technical Reports Server (NTRS)

    2010-01-01

    This document represents a summary of medical and scientific evaluations conducted aboard the C-9 and other NASA-sponsored aircraft from June 2009 to June 2010. Included is a general overview of investigations manifested and coordinated by the Human Adaptation and Countermeasures Division. A collection of brief reports that describe tests conducted aboard the NASA-sponsored aircraft follows the overview. Principal investigators and test engineers contributed significantly to the content of the report, describing their particular experiment or hardware evaluation. Although this document follows general guidelines, each report format may vary to accommodate differences in experiment design and procedures. This document concludes with an appendix that provides background information concerning the Reduced Gravity Program.

  19. The relationship between study sponsorship, risks of bias, and research outcomes in atrazine exposure studies conducted in non-human animals: Systematic review and meta-analysis.

    PubMed

    Bero, L; Anglemyer, A; Vesterinen, H; Krauth, D

    2016-01-01

    A critical component of systematic review methodology is the assessment of the risks of bias of studies that are included in the review. There is controversy about whether funding source should be included in a risk of bias assessment of animal toxicology studies. To determine whether industry research sponsorship is associated with methodological biases, the results, or conclusions of animal studies examining the effect of exposure to atrazine on reproductive or developmental outcomes. We searched multiple electronic databases and the reference lists of relevant articles to identify original research studies examining the effect of any dose of atrazine exposure at any life stage on reproduction or development in non-human animals. We compared methodological risks of bias, the conclusions of the studies, the statistical significance of the findings, and the magnitude of effect estimates between industry sponsored and non-industry sponsored studies. Fifty-one studies met the inclusion criteria. There were no differences in methodological risks of bias in industry versus non-industry sponsored studies. 39 studies tested environmentally relevant concentrations of atrazine (11 industry sponsored, 24 non-industry sponsored, 4 with no funding disclosures). Non-industry sponsored studies (12/24, 50.0%) were more likely to conclude that atrazine was harmful compared to industry sponsored studies (2/11, 18.1%) (p value=0.07). A higher proportion of non-industry sponsored studies reported statistically significant harmful effects (8/24, 33.3%) compared to industry-sponsored studies (1/11; 9.1%) (p value=0.13). The association of industry sponsorship with decreased effect sizes for harm outcomes was inconclusive. Our findings support the inclusion of research sponsorship as a risk of bias criterion in tools used to assess risks of bias in animal studies for systematic reviews. The reporting of other empirically based risk of bias criteria for animal studies, such as blinded outcome assessment, randomization, and all animals included in analyses, needs to improve to facilitate the assessment of studies for systematic reviews. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Interlaboratory Evaluation of in Vitro Cytotoxicity and Inflammatory Responses to Engineered Nanomaterials: The NIEHS Nano GO Consortium

    PubMed Central

    Xia, Tian; Hamilton, Raymond F.; Bonner, James C.; Crandall, Edward D.; Elder, Alison; Fazlollahi, Farnoosh; Girtsman, Teri A.; Kim, Kwang; Mitra, Somenath; Ntim, Susana A.; Orr, Galya; Tagmount, Mani; Taylor, Alexia J.; Telesca, Donatello; Tolic, Ana; Vulpe, Christopher D.; Walker, Andrea J.; Wang, Xiang; Witzmann, Frank A.; Wu, Nianqiang; Xie, Yumei; Zink, Jeffery I.; Nel, Andre

    2013-01-01

    Background: Differences in interlaboratory research protocols contribute to the conflicting data in the literature regarding engineered nanomaterial (ENM) bioactivity. Objectives: Grantees of a National Institute of Health Sciences (NIEHS)-funded consortium program performed two phases of in vitro testing with selected ENMs in an effort to identify and minimize sources of variability. Methods: Consortium program participants (CPPs) conducted ENM bioactivity evaluations on zinc oxide (ZnO), three forms of titanium dioxide (TiO2), and three forms of multiwalled carbon nanotubes (MWCNTs). In addition, CPPs performed bioassays using three mammalian cell lines (BEAS-2B, RLE-6TN, and THP-1) selected in order to cover two different species (rat and human), two different lung epithelial cells (alveolar type II and bronchial epithelial cells), and two different cell types (epithelial cells and macrophages). CPPs also measured cytotoxicity in all cell types while measuring inflammasome activation [interleukin-1β (IL-1β) release] using only THP-1 cells. Results: The overall in vitro toxicity profiles of ENM were as follows: ZnO was cytotoxic to all cell types at ≥ 50 μg/mL, but did not induce IL-1β. TiO2 was not cytotoxic except for the nanobelt form, which was cytotoxic and induced significant IL-1β production in THP-1 cells. MWCNTs did not produce cytotoxicity, but stimulated lower levels of IL-1β production in THP-1 cells, with the original MWCNT producing the most IL-1β. Conclusions: The results provide justification for the inclusion of mechanism-linked bioactivity assays along with traditional cytotoxicity assays for in vitro screening. In addition, the results suggest that conducting studies with multiple relevant cell types to avoid false-negative outcomes is critical for accurate evaluation of ENM bioactivity. PMID:23649538

  1. Comparison of Hepatic 2D Sandwich Cultures and 3D Spheroids for Long-term Toxicity Applications: A Multicenter Study

    PubMed Central

    Bell, Catherine C; Dankers, Anita C A; Sison-Young, Rowena; Jenkins, Roz; Rowe, Cliff; Goldring, Chris E; Park, Kevin; Regan, Sophie L; Walker, Tracy; Schofield, Chris; Baze, Audrey; Foster, Alison J; Williams, Dominic P; van de Ven, Amy W M; Jacobs, Frank; van Houdt, Jos; Lähteenmäki, Tuula; Snoeys, Jan; Juhila, Satu; Richert, Lysiane; Ingelman-Sundberg, Magnus

    2018-01-01

    Abstract Primary human hepatocytes (PHHs) are commonly used for in vitro studies of drug-induced liver injury. However, when cultured as 2D monolayers, PHH lose crucial hepatic functions within hours. This dedifferentiation can be ameliorated when PHHs are cultured in sandwich configuration (2Dsw), particularly when cultures are regularly re-overlaid with extracellular matrix, or as 3D spheroids. In this study, the 6 participating laboratories evaluated the robustness of these 2 model systems made from cryopreserved PHH from the same donors considering both inter-donor and inter-laboratory variability and compared their suitability for use in repeated-dose toxicity studies using 5 different hepatotoxins with different toxicity mechanisms. We found that expression levels of proteins involved in drug absorption, distribution, metabolism, and excretion, as well as catalytic activities of 5 different CYPs, were significantly higher in 3D spheroid cultures, potentially affecting the exposure of the cells to drugs and their metabolites. Furthermore, global proteomic analyses revealed that PHH in 3D spheroid configuration were temporally stable whereas proteomes from the same donors in 2Dsw cultures showed substantial alterations in protein expression patterns over the 14 days in culture. Overall, spheroid cultures were more sensitive to the hepatotoxic compounds investigated, particularly upon long-term exposures, across testing sites with little inter-laboratory or inter-donor variability. The data presented here suggest that repeated-dosing regimens improve the predictivity of in vitro toxicity assays, and that PHH spheroids provide a sensitive and robust system for long-term mechanistic studies of drug-induced hepatotoxicity, whereas the 2Dsw system has a more dedifferentiated phenotype and lower sensitivity to detect hepatotoxicity. PMID:29329425

  2. Interlaboratory study of the ion source memory effect in 36Cl accelerator mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pavetich, Stefan; Akhmadaliev, Shavkat; Arnold, Maurice; Aumaître, Georges; Bourlès, Didier; Buchriegler, Josef; Golser, Robin; Keddadouche, Karim; Martschini, Martin; Merchel, Silke; Rugel, Georg; Steier, Peter

    2014-06-01

    Understanding and minimization of contaminations in the ion source due to cross-contamination and long-term memory effect is one of the key issues for accurate accelerator mass spectrometry (AMS) measurements of volatile elements. The focus of this work is on the investigation of the long-term memory effect for the volatile element chlorine, and the minimization of this effect in the ion source of the Dresden accelerator mass spectrometry facility (DREAMS). For this purpose, one of the two original HVE ion sources at the DREAMS facility was modified, allowing the use of larger sample holders having individual target apertures. Additionally, a more open geometry was used to improve the vacuum level. To evaluate this improvement in comparison to other up-to-date ion sources, an interlaboratory comparison had been initiated. The long-term memory effect of the four Cs sputter ion sources at DREAMS (two sources: original and modified), ASTER (Accélérateur pour les Sciences de la Terre, Environnement, Risques) and VERA (Vienna Environmental Research Accelerator) had been investigated by measuring samples of natural 35Cl/37Cl-ratio and samples highly-enriched in 35Cl (35Cl/37Cl ∼ 999). Besides investigating and comparing the individual levels of long-term memory, recovery time constants could be calculated. The tests show that all four sources suffer from long-term memory, but the modified DREAMS ion source showed the lowest level of contamination. The recovery times of the four ion sources were widely spread between 61 and 1390 s, where the modified DREAMS ion source with values between 156 and 262 s showed the fastest recovery in 80% of the measurements.

  3. Agreement in assessment of infliximab and adalimumab levels in rheumatoid arthritis: interlaboratory and interassay comparison.

    PubMed

    Valor, Lara; Hernández-Flórez, Diana; de la Torre, Inmaculada; Llinares, Francisca; Rosas, José; Yagüe, Jordi; Garrido, Jesús; Naredo, Esperanza

    2015-01-01

    Infliximab (IFX) and adalimumab (ADL) drug levels and anti-drug antibodies (ADA) are assessed using a variety of techniques, therefore, results cannot accurately be compared for clinical purposes. The aim of this study was to test two infliximab (IFX) and adalimumab (ADL) ELISA versions, for drug levels and ADA, to see whether they yield similar results. ELISA versions [Promonitor® IFX R1 and R2 (V.1), Promonitor® IFX and Anti-IFX (V.2); Promonitor® ADL R1 and R2 (V.1), Promonitor® ADL and Anti-ADL (V.2) kits (Progenika Biopharma, Spain)] were used to measure drug levels and ADA in IFX (n=24) and ADL (n=24) rheumatoid arthritis-treated patients in three independent laboratories. Quantitative and qualitative agreements were evaluated using intraclass correlation coefficients (ICC), and Cohen's Kappa (κ) respectively. The Bland-Altman plots assessed differences between V.1 and V.2. Interlaboratory agreement (ICC/κ) with V.1 was poor for IFX (0.66/0.62) and ADL (0.69/0.52) drug levels; meanwhile, high agreement was found with V.2 for IFX (0.98/0.95) and ADL (0.094/1.00). Comparison between V.1 and V.2 in each laboratory resulted in systematically higher values in V.2 than in V.1 and poor agreement (ICC/κ ranges) for IFX (0.12-0.7/ 0.19-0.42) and ADL (0.69-0.89 /0.50-0.73). Qualitative measurements result in better agreement, as evidenced in our study. Greater agreement in V.2 compared with V.1 for IFX and ADL levels could be due to a better tune up. Further studies are required to standardise methods to establish therapeutic reference ranges.

  4. [The pilot program in Mexican clinical laboratories. I. The characterization of structure and productivity].

    PubMed

    de Gortari, E; Herrera, M; Loría, A; Terrés, A; González-Salayandia, M A; Hernández, M A

    1994-01-01

    To validate a questionnaire which evaluates the structure of clinical laboratories and to obtain information on its productivity. A group of 18 laboratories belonging to hospitals of second (N = 15) and third (N = 3) levels of health care. Fifteen participants belong to the public sector and three are first rate private institutions. They are located in the metropolitan area of Mexico City comprising the Federal District (N = 12) and the State of Mexico (N = 6). The questionnaire has 12 items which received a 0, 1/2 or 1 score. The maximum possible score for a perfect laboratory as well as for any question is 100. The questionnaire was filled during a visit to the participating hospitals by auditors of the agency of the Ministry of Health in charge of licensing laboratories at a national level. Information covering six months of work was obtained to calculate productivity using number of tests per worker per month. The global score of the 18 participants was 49. The private ones had the highest scores (79 to 96) which was to be expected as they were selected for their high technical and human resources. The five State laboratories had a score above the global mean, but only one of the Federal ones was in this situation. A high interlaboratory variability was observed, i.e. productivity in the highest rated was nine times larger than in the lowest rated. This finding suggests the presence of interlaboratory differences in the criteria used in the collection of productivity information. This short questionnaire can be used as a first approximation to identify structure deficiencies of the Mexican clinical laboratories.

  5. Measurement of the Out-of-Plane Shear Response of Thick Section Composite Materials Using the V-Notched Beam Specimen

    DTIC Science & Technology

    1993-04-01

    to failure at 1.25 mm/min.(.05 in./min.) by a hydraulic, 267 kN (60,000 lb.) capacity, Satec testing machine. Strain output was conditioned through...D.Hoyns 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS( ES ) ’S. PERFORMING ORGANIZATION REPORT NUMBER Naval Surface Warfare Center Carderock Division...Annapolis Detachment CRDKNSWC-SSM-64-92/22 Code 2844/644 9. SPONSORING /MON7ORING AGENCY NAME(S) AND ADDRESS( ES ) 10. SPONSORING /MONITOR INGAGENCY REPORT

  6. Normobaric Hypoxia as a Cognitive Stress Test for Mild Traumatic Brain Injury: Oculometrics, Pulse Oximetry, and the Self Report of Symptom Severity

    DTIC Science & Technology

    2011-06-20

    USAMRMC Reg 70-25 on Use of Volunteers in Research. Standard Form 298 (Rev. 8 /98) REPORT DOCUMENTATION PAGE Prescribed by ANSI Std. Z39.18 Form...ORGANIZATION NAME(S) AND ADDRESS(ES) 8 . PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR...group of control subjects ......................................28  8 . Saccadic velocity as a function of hypoxic condition averaged for the group of mild

  7. The Occupational Health Nurse (OHN) and the Implications for Nursing Education

    DTIC Science & Technology

    1992-01-01

    539-556. Yancey, W. B., Jr ., & Williams , R. C. Jr . (1991). Laboratory tests for rheumatic diseases. Postgraduate Medici., _U(2), 93-6, 99-100, 103. OHN...034 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSORING/MONITORING AGENCY REPORT NUMBER AFIT/CI Wright- Patterson AFB OH 45433-6583 11... ERNEST A. HAYGOOD, Captain, USAF Executive Officer 13. ABSTRACT (Maximum 200 words) OTIC .1111UfMON BTATEBM~ A ELECTE AfwY I"m" pu~ " r ~DTIC v𔃽 92-17995

  8. Discovery of Novel N-Nicotinamide Methyltransferase Inhibitors to Combat Obesity-Linked Osteoarthritis and Metabolic Disease Among Veterans and Beneficiaries

    DTIC Science & Technology

    2016-10-01

    Medical Branch at Galveston Galveston, TX 77555 REPORT DATE: October 2016 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research and...SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland 21702-5012 11. SPONSOR/MONITOR’S REPORT NUMBER(S...testing of in silico hits 1.1. Complete project hiring Research scientists hired February 1, 2016 and February 15, 2016. Research technician hired

  9. Theranostics Targeting Metastatic Breast Cancer

    DTIC Science & Technology

    2017-10-01

    Methodist Hospital Houston, TX 77030 REPORT DATE: October 2017 TYPE OF REPORT: Annual PREPARED FOR: U.S. Army Medical Research and Materiel Command...77030 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S) U.S. Army Medical Research and Materiel Command Fort...near-IR imaging agents and PDT therapeutics in vivo (see below). They will be tested in this upcoming research year. N+ -O3S N SO3- N+Me3Me3+N OO YI

  10. Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL Contamination in the Subsurface

    DTIC Science & Technology

    2008-03-01

    aquifer interrogated during the test using: w NAPL S S K1R +== radon tracer V V (3) where R is the retardation factor (dimensionless), Vtracer is...NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR( S ) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME( S ) AND...MONITORING AGENCY NAME( S ) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM( S ) 11. SPONSOR/MONITOR’S REPORT NUMBER( S ) 12. DISTRIBUTION/AVAILABILITY STATEMENT

  11. Industry sponsored anti-smoking ads and adolescent reactance: test of a boomerang effect.

    PubMed

    Henriksen, L; Dauphinee, A L; Wang, Y; Fortmann, S P

    2006-02-01

    To examine whether adolescents' exposure to youth smoking prevention ads sponsored by tobacco companies promotes intentions to smoke, curiosity about smoking, and positive attitudes toward the tobacco industry. A randomised controlled experiment compared adolescents' responses to five smoking prevention ads sponsored by a tobacco company (Philip Morris or Lorillard), or to five smoking prevention ads sponsored by a non-profit organisation (the American Legacy Foundation), or to five ads about preventing drunk driving. A large public high school in California's central valley. A convenience sample of 9th and 10th graders (n = 832) ages 14-17 years. Perceptions of ad effectiveness, intention to smoke, and attitudes toward tobacco companies measured immediately after exposure. As predicted, adolescents rated Philip Morris and Lorillard ads less favourably than the other youth smoking prevention ads. Adolescents' intention to smoke did not differ as a function of ad exposure. However, exposure to Philip Morris and Lorillard ads engendered more favourable attitudes toward tobacco companies. This study demonstrates that industry sponsored anti-smoking ads do more to promote corporate image than to prevent youth smoking. By cultivating public opinion that is more sympathetic toward tobacco companies, the effect of such advertising is likely to be more harmful than helpful to youth.

  12. Inter-laboratory comparison of xenobiotic clearance rates determined using cryopreserved trout hepatocytes for improving bioaccumulation predictions

    EPA Science Inventory

    Hepatic biotransformation is an important determinant of chemical bioaccumulation in fish. Consequently, bioaccumulation models can be improved using estimates of chemical biotransformation rates. Cryopreserved trout hepatocytes have been used to measure the clearance rates of so...

  13. Inter-laboratory comparison of clearance rates of xenobiotics by cryopreserved trout hepatocytes for the prediction of bioaccumulation potential

    EPA Science Inventory

    Hepatic biotransformation is an important determinant of chemical bioaccumulation in fish. Consequently, improvements to bioaccumulation models can be made using estimates of chemical biotransformation rates. Cryopreserved trout hepatocytes have previously been used to measure ...

  14. INTERLABORATORY METHODS COMPARISON FOR THE TOTAL ORGANIC CARBON ANALYSIS OF AQUIFER MATERIALS

    EPA Science Inventory

    The total organic carbon (TOC) content of aquifer materials has been found to have significant effects on the movement of pollutants in the subsurface environment. Accurate quantification of TOC is therefore of great im- portance to research in groundwater contamination. However,...

  15. 9 CFR 439.51 - Probation of accreditation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... ACCREDITATION OF NON-FEDERAL CHEMISTRY LABORATORIES § 439.51 Probation of accreditation. Upon a determination by the Administrator, a laboratory will be placed on probation for the following reasons: (a) If the laboratory fails to complete more than one interlaboratory accreditation maintenance check sample analysis as...

  16. An Experimental Introduction to Interlaboratory Exercises in Analytical Chemistry

    ERIC Educational Resources Information Center

    Puignou, L.; Llaurado, M.

    2005-01-01

    An experimental exercise on analytical proficiency studies in collaborative trials is proposed. This practical provides students in advanced undergraduate courses in chemistry, pharmacy, and biochemistry, with the opportunity to improve their quality assurance skills. It involves an environmental analysis, determining the concentration of a…

  17. Fish species identification using PCR-RFLP analysis and lab-on-a-chip capillary electrophoresis: application to detect white fish species in food products and an interlaboratory study.

    PubMed

    Dooley, John J; Sage, Helen D; Clarke, Marie-Anne L; Brown, Helen M; Garrett, Stephen D

    2005-05-04

    Identification of 10 white fish species associated with U.K. food products was achieved using PCR-RFLP of the mitochondrial cytochrome b gene. Use of lab-on-a-chip capillary electrophoresis for end-point analysis enabled accurate sizing of DNA fragments and identification of fish species at a level of 5% (w/w) in a fish admixture. One restriction enzyme, DdeI, allowed discrimination of eight species. When combined with NlaIII and HaeIII, specific profiles for all 10 species were generated. The method was applied to a range of products and subjected to an interlaboratory study carried out by five U.K. food control laboratories. One hundred percent correct identification of single species samples and six of nine admixture samples was achieved by all laboratories. The results indicated that fish species identification could be carried out using a database of PCR-RFLP profiles without the need for reference materials.

  18. Liquid chromatographic determination of histamine in fish, sauerkraut, and wine: interlaboratory study.

    PubMed

    Beljaars, P R; Van Dijk, R; Jonker, K M; Schout, L J

    1998-01-01

    An interlaboratory study of the liquid chromatographic (LC) determination of histamine in fish, sauerkraut, and wine was conducted. Diminuted and homogenized samples were suspended in water followed by clarification of extracts with perchloric acid, filtration, and dilution with water. After LC separation on a reversed-phase C18 column with phosphate buffer (pH 3.0)--acetonitrile (875 + 125, v/v) as mobile phase, histamine was measured fluorometrically (excitation, 340 nm; emission, 455 nm) in samples and standards after postcolumn derivatization with o-phthaldialdehyde (OPA). Fourteen samples (including 6 blind duplicates and 1 split level) containing histamine at about 10-400 mg/kg or mg/L were analyzed singly according to the proposed procedure by 11 laboratories. Results from one participant were excluded from statistical analysis. For all samples analyzed, repeatability relative standard deviations varied from 2.1 to 5.6%, and reproducibility relative standard deviations ranged from 2.2 to 7.1%. Averaged recoveries of histamine for this concentration range varied from 94 to 100%.

  19. Certification by the Karl Fischer method of the water content in SRM 2890, Water Saturated 1-Octanol, and the analysis of associated interlaboratory bias in the measurement process.

    PubMed

    Margolis, S A; Levenson, M

    2000-05-01

    The calibration of Karl Fischer instruments and reagents and the compensation for instrumental bias are essential to the accurate measurement of trace levels of water in organic and inorganic chemicals. A stable, nonhygroscopic standard, Water Saturated Octanol, which is compatible with the Karl Fischer reagents, has been prepared. This material, Standard Reference Material (SRM) 2890, is homogeneous and is certified to contain 39.24 +/- 0.85 mg water/mL (expanded uncertainty) of solution (47.3 +/- 1.0 mg water/g solution, expanded uncertainty) at 21.5 degrees C. The solubility of water in -octanol has been shown to be nearly constant between 10 degrees C and 30 degrees C (i.e., within 1% of the value at 21.5 degrees C). The results of an interlaboratory comparison exercise illustrate the utility of SRM 2890 in assessing the accuracy and bias of Karl Fischer instruments and measurements.

  20. GaMin’11 – an international inter-laboratory comparison for geochemical CO₂ - saline fluid - mineral interaction experiments

    DOE PAGES

    Ostertag-Henning, C.; Risse, A.; Thomas, B.; ...

    2014-12-31

    Due to the strong interest in geochemical CO₂-fluid-rock interaction in the context of geological storage of CO₂ a growing number of research groups have used a variety of different experimental ways to identify important geochemical dissolution or precipitation reactions and – if possible – quantify the rates and extent of mineral or rock alteration. In this inter-laboratory comparison the gas-fluid-mineral reactions of three samples of rock-forming minerals have been investigated by 11 experimental labs. The reported results point to robust identification of the major processes in the experiments by most groups. The dissolution rates derived from the changes in compositionmore » of the aqueous phase are consistent overall, but the variation could be reduced by using similar corrections for changing parameters in the reaction cells over time. The comparison of experimental setups and procedures as well as of data corrections identified potential improvements for future gas-fluid-rock studies.« less

  1. Employee Drug Testing Policies in Police Departments. Research in Brief.

    ERIC Educational Resources Information Center

    McEwen, J. Thomas; And Others

    1986-01-01

    The development of drug testing policies and the implementation of drug testing procedures involve legal, ethical, medical, and labor relations issues. To learn how police departments are addressing the problem of drug use and drug testing of police officers, the National Institute of Justice sponsored a telephone survey of 33 major police…

  2. 75 FR 1179 - Passenger Equipment Safety Standards; Front End Strength of Cab Cars and Multiple-Unit Locomotives

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-08

    ... Dynamic and Quasi-Static Testing in 2008 a. Test Article Design b. Dynamic Testing of a Collision Post c... requirements concerning structural deformation and energy absorption by collision posts and corner posts at the... Testing in 2002 a. Test Article Designs b. Dynamic Impact Testing c. Analysis 2. Industry-Sponsored Quasi...

  3. Inoculum selection influences the biochemical methane potential of agro-industrial substrates

    PubMed Central

    De Vrieze, Jo; Raport, Linde; Willems, Bernard; Verbrugge, Silke; Volcke, Eveline; Meers, Erik; Angenent, Largus T; Boon, Nico

    2015-01-01

    Obtaining a reliable estimation of the methane potential of organic waste streams in anaerobic digestion, for which a biochemical methane potential (BMP) test is often used, is of high importance. Standardization of this BMP test is required to ensure inter-laboratory repeatability and accuracy of the BMP results. Therefore, guidelines were set out; yet, these do not provide sufficient information concerning origin of and the microbial community in the test inoculum. Here, the specific contribution of the methanogenic community on the BMP test results was evaluated. The biomethane potential of four different substrates (molasses, bio-refinery waste, liquid manure and high-rate activated sludge) was determined by means of four different inocula from full-scale anaerobic digestion plants. A significant effect of the selected inoculum on the BMP result was observed for two out of four substrates. This inoculum effect could be attributed to the abundance of methanogens and a potential inhibiting effect in the inoculum itself, demonstrating the importance of inoculum selection for BMP testing. We recommend the application of granular sludge as an inoculum, because of its higher methanogenic abundance and activity, and protection from bulk solutions, compared with other inocula. PMID:25756301

  4. Results of an inter-laboratory study of glass formulation for the immobilization of excess plutonium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peeler, D.K.

    1999-12-08

    The primary focus of the current study is to determine allowable loadings of feed streams containing different ratios of plutonium, uranium, and minor components into the LaBS glass and to evaluate thermal stability with respect to the DWPF pour.

  5. In vitro to in vivo extrapolation of hepatic metabolism in fish: An inter-laboratory comparison of in vitro methods - presentation

    EPA Science Inventory

    Chemical biotransformation represents the largest source of uncertainty in chemical bioaccumulation assessments. Model-based estimates of chemical bioconcentration in fish may be greatly improved by including biotransformation rates, as measured in vitro. Substrate depletion assa...

  6. CAPILLARY GAS CHROMATOGRAPHY-ATOMIC EMISSION DETECTION METHOD FOR THE DETERMINATION OF PENTYLATED ORGANOTIN COMPOUNDS: INTERLABORATORY STUDY

    EPA Science Inventory

    A capillary gas chromatography-atomic emission detection (GC-AED) method was developed for the U. S. Environmental Protection Agency's Environmental Monitoring Systems Laboratory in Las Vegas, NV, for determination of selected organotin compounds. Here we report on an interlabora...

  7. DIRECT operational field test evaluation natural use study. Part 1, Subject stated response

    DOT National Transportation Integrated Search

    1998-08-01

    This report presents evaluation results from the Subject Stated Response portion (Part I) of the Natural Use Study of the DIRECT (Driver Information Radio using Experimental Communication : Technologies) operational test sponsored by the Michigan Dep...

  8. Portable traffic management system smart work zone application : operational test evaluation report

    DOT National Transportation Integrated Search

    1997-05-01

    As part of its statewide Intelligent Transportation System (ITS), The Minnesota Department of Transportation (Mn/DOT) sponsored an operational test of the Portable Traffic Management System (PTMS) in a work zone application in cooperation with its pr...

  9. Computer-aided dispatch--traffic management center field operational test : Washington State final report

    DOT National Transportation Integrated Search

    2006-05-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...

  10. Marine Engine-Exhaust Emissions Test Cell

    DOT National Transportation Integrated Search

    1974-11-01

    A marine engine exhaust emissions test cell for boat-size diesel engines (approx. 200 hp) and outboard engines was constructed as part of a project sponsored by the United States Coast Guard for the monitoring and control of emissions from marine sou...

  11. Heavy and overweight vehicle brake testing : combination five-axle tractor-flatbed, final report

    DOT National Transportation Integrated Search

    2017-05-01

    The Federal Motor Carrier Safety Administration (FMCSA), in coordination with the Federal Highway Administration (FHWA), sponsored the Heavy and Overweight Vehicle Brake Testing (HOVBT) program in order to provide information about the effect of gros...

  12. Evaluation of the Anaheim Advanced Traffic Control System Field Operational Test : executive summary

    DOT National Transportation Integrated Search

    1999-07-01

    This Executive Summary provides an overview of the technical and institutional issues associated with the evaluation of the federally-sponsored Anaheim Advanced Traffic Control : System Field Operations Test. The primary FOT objective was the impleme...

  13. KSC-00pp0315

    NASA Image and Video Library

    2000-03-09

    Team 393 from Morristown, Ind., sets up its robot on a table to prepare it for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 at the KSC Visitor Complex. KSC is co-sponsoring the team, The Bee Bots, from Morristown Junior and Senior High Schools. On the floor at right is team 386, known as Voltage: The South Brevard First Team. This team is made up of students from Eau Gallie, Satellite, Palm Bay, Melbourne, Bayside and Melbourne Central Catholic High Schools. They are sponsored by KSC as well as Harris Corp., Intersil Corp., Interface & Control Systems. Inc. and Rockwell Collins. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing at KSC, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  14. Teams begin their preparations for the FIRST competition

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Team 393 from Morristown, Ind., sets up its robot on a table to prepare it for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 at the KSC Visitor Complex. KSC is co-sponsoring the team, The Bee Bots, from Morristown Junior and Senior High Schools. On the floor at right is team 386, known as Voltage: The South Brevard First Team. This team is made up of students from Eau Gallie, Satellite, Palm Bay, Melbourne, Bayside and Melbourne Central Catholic High Schools. They are sponsored by KSC as well as Harris Corp., Intersil Corp., Interface & Control Systems. Inc. and Rockwell Collins. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing at KSC, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville.

  15. KSC00pp0315

    NASA Image and Video Library

    2000-03-09

    Team 393 from Morristown, Ind., sets up its robot on a table to prepare it for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 at the KSC Visitor Complex. KSC is co-sponsoring the team, The Bee Bots, from Morristown Junior and Senior High Schools. On the floor at right is team 386, known as Voltage: The South Brevard First Team. This team is made up of students from Eau Gallie, Satellite, Palm Bay, Melbourne, Bayside and Melbourne Central Catholic High Schools. They are sponsored by KSC as well as Harris Corp., Intersil Corp., Interface & Control Systems. Inc. and Rockwell Collins. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing at KSC, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  16. A cooperative network of trained sites for the conduct of a complex clinical trial: a new concept in multicenter clinical research.

    PubMed

    Davidson, Robert M; McNeer, J Frederick; Logan, Leanne; Higginbotham, Michael B; Anderson, Jerome; Blackshear, Joseph; Chu, Alan; Hettleman, Bruce; McGrew, Frank; Meesse, Roderick; O'Connor, Christopher; Schneider, Ricky; Wagner, Galen S

    2006-02-01

    The purpose of this report is to present a model of physicians in full-time clinical practice participating as investigators in multicenter clinical trials, sponsored by a pharmaceutical or medical device company. This gas-exchange substudy was conducted as a pilot study to establish the feasibility of the 10-member EXERcise testing group of the Duke University Cooperative Cardiovascular Society (EXERDUCCS) consortium to perform a complex multicenter trial using cardiopulmonary exercise testing. An active interchange of information was established involving the principal investigator for the substudy, a dedicated full-time project coordinator, a medical director of the overall EXERDUCCS network site, the project coordinator for the sponsor, and all the participating EXERDUCCS investigators and coordinators. The sponsor set as a goal of enrollment of 6 subjects per site, and 8 of the 10 sites met this goal. As a result of the successful enrollment and completion of the study and substudy by the EXERDUCCS sites, the sponsor subsequently increased the payment stipends to the sites to compensate for the extra work and expense incurred. This cooperative experience accomplished several goals: (1) it allowed a complex clinical trial to be successfully completed in a time frame which would not have been possible using only single unconnected sites; (2) it educated the physician-investigators (and their personnel) in exercise cardiopulmonary; and (3) it prepared the sites for future clinical trials involving this methodology.

  17. Catch-up validation study of an in vitro skin irritation test method based on an open source reconstructed epidermis (phase II).

    PubMed

    Groeber, F; Schober, L; Schmid, F F; Traube, A; Kolbus-Hernandez, S; Daton, K; Hoffmann, S; Petersohn, D; Schäfer-Korting, M; Walles, H; Mewes, K R

    2016-10-01

    To replace the Draize skin irritation assay (OECD guideline 404) several test methods based on reconstructed human epidermis (RHE) have been developed and were adopted in the OECD test guideline 439. However, all validated test methods in the guideline are linked to RHE provided by only three companies. Thus, the availability of these test models is dependent on the commercial interest of the producer. To overcome this limitation and thus to increase the accessibility of in vitro skin irritation testing, an open source reconstructed epidermis (OS-REp) was introduced. To demonstrate the capacity of the OS-REp in regulatory risk assessment, a catch-up validation study was performed. The participating laboratories used in-house generated OS-REp to assess the set of 20 reference substances according to the performance standards amending the OECD test guideline 439. Testing was performed under blinded conditions. The within-laboratory reproducibility of 87% and the inter-laboratory reproducibility of 85% prove a high reliability of irritancy testing using the OS-REp protocol. In addition, the prediction capacity was with an accuracy of 80% comparable to previous published RHE based test protocols. Taken together the results indicate that the OS-REp test method can be used as a standalone alternative skin irritation test replacing the OECD test guideline 404. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. State Test Score Trends through 2008-09, Part 1: Rising Scores on State Tests and NAEP

    ERIC Educational Resources Information Center

    Chudowsky, Naomi; Chudowsky, Victor

    2010-01-01

    In recent years, scores on the annual state reading and mathematics tests used for accountability have gone up in most states. These trends in state test scores do not always coincide, however, with trends on the National Assessment of Educational Progress (NAEP), the federally sponsored assessment that is administered periodically to…

  19. Industry sponsorship and research outcome.

    PubMed

    Lundh, Andreas; Sismondo, Sergio; Lexchin, Joel; Busuioc, Octavian A; Bero, Lisa

    2012-12-12

    Clinical research affecting how doctors practice medicine is increasingly sponsored by companies that make drugs and medical devices. Previous systematic reviews have found that pharmaceutical industry sponsored studies are more often favorable to the sponsor's product compared with studies with other sources of sponsorship. This review is an update using more stringent methodology and also investigating sponsorship of device studies. To investigate whether industry sponsored drug and device studies have more favorable outcomes and differ in risk of bias, compared with studies having other sources of sponsorship. We searched MEDLINE (1948 to September 2010), EMBASE (1980 to September 2010), the Cochrane Methodology Register (Issue 4, 2010) and Web of Science (August 2011). In addition, we searched reference lists of included papers, previous systematic reviews and author files. Cross-sectional studies, cohort studies, systematic reviews and meta-analyses that quantitatively compared primary research studies of drugs or medical devices sponsored by industry with studies with other sources of sponsorship. We had no language restrictions. Two assessors identified potentially relevant papers, and a decision about final inclusion was made by all authors. Two assessors extracted data, and we contacted authors of included papers for additional unpublished data. Outcomes included favorable results, favorable conclusions, effect size, risk of bias and whether the conclusions agreed with the study results. Two assessors assessed risk of bias of included papers. We calculated pooled risk ratios (RR) for dichotomous data (with 95% confidence intervals). Forty-eight papers were included. Industry sponsored studies more often had favorable efficacy results, risk ratio (RR): 1.24 (95% confidence interval (CI): 1.14 to 1.35), harms results RR: 1.87 (95% CI: 1.54 to 2.27) and conclusions RR: 1.31 (95% CI: 1.20 to 1.44) compared with non-industry sponsored studies. Ten papers reported on sponsorship and effect size, but could not be pooled due to differences in their reporting of data. The results were heterogeneous; five papers found larger effect sizes in industry sponsored studies compared with non-industry sponsored studies and five papers did not find a difference in effect size. Only two papers (including 120 device studies) reported separate data for devices and we did not find a difference between drug and device studies on the association between sponsorship and conclusions (test for interaction, P = 0.23). Comparing industry and non-industry sponsored studies, we did not find a difference in risk of bias from sequence generation, allocation concealment and follow-up. However, industry sponsored studies more often had low risk of bias from blinding, RR: 1.32 (95% CI: 1.05 to 1.65), compared with non-industry sponsored studies. In industry sponsored studies, there was less agreement between the results and the conclusions than in non-industry sponsored studies, RR: 0.84 (95% CI: 0.70 to 1.01). Sponsorship of drug and device studies by the manufacturing company leads to more favorable results and conclusions than sponsorship by other sources. Our analyses suggest the existence of an industry bias that cannot be explained by standard 'Risk of bias' assessments.

  20. Unfulfilled translation opportunities in industry sponsored clinical trials.

    PubMed

    Smed, Marie; Getz, Kenneth A

    2013-05-01

    Knowledge generated by site representatives through their participation in clinical trials is valuable for testing new products in use and obtaining final market approval. The leverage of this important knowledge is however challenged as the former direct relationships between in-house staff in the industry and site representatives are changing. The process of clinical trials has increased in complexity over the years, resulting in additional management layers. Besides an increase in internal management layers, sponsors often also outsource various tasks related to clinical trials to a CRO (Contract Research Organization) and thereby adding another link in the relationships between site and sponsor. These changes are intended to optimize the time-consuming and costly trial phases; however, there is a need to study whether valuable knowledge and experience is compromised in the process. Limited research exists on the full range of clinical practice insights obtained by investigators during and after clinical trials and how well these insights are transferred to study sponsors. This study explores the important knowledge-transfer processes between sites and sponsors and to what extent sites' knowledge gained in clinical trials is utilized by the industry. Responses from 451 global investigative site representatives are included in the study. The analysis of the extensive dataset reveals that the current processes of collaboration between sites and the industry restrict the leverage of valuable knowledge gained by physicians in the process of clinical trials. These restrictions to knowledge-transfer between site and sponsor are further challenged if CRO partners are integrated in the trial process. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. KSC00pp0349

    NASA Image and Video Library

    2000-03-10

    The Hero Team (278) robot, named Hero, is repaired in a Kennedy Space Center research and development machine shop. The team of Edgewater High School students was co-sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  2. KSC-00pp0349

    NASA Image and Video Library

    2000-03-10

    The Hero Team (278) robot, named Hero, is repaired in a Kennedy Space Center research and development machine shop. The team of Edgewater High School students was co-sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  3. KSC00pp0335

    NASA Image and Video Library

    2000-03-10

    The Hero Team (278) robot, named Hero, is repaired in a Kennedy Space Center research and development machine shop. The team of Edgewater High School students was co-sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  4. Effects of Disclosing Sponsored Content in Blogs

    PubMed Central

    van Reijmersdal, Eva A.; Fransen, Marieke L.; van Noort, Guda; Opree, Suzanna J.; Vandeberg, Lisa; Reusch, Sanne; van Lieshout, Floor; Boerman, Sophie C.

    2016-01-01

    This article presents two studies examining the effects of disclosing online native advertising (i.e., sponsored content in blogs) on people’s brand attitude and purchase intentions. To investigate the mechanisms underlying these effects, we integrated resistance theories with the persuasion knowledge model. We theorize that disclosures activate people’s persuasion knowledge, which in turn evokes resistance strategies that people use to cope with the persuasion attempt made in the blog. We tested our predications with two experiments (N = 118 and N = 134). We found that participants indeed activated persuasion knowledge in response to disclosures, after which they used both cognitive (counterarguing) and affective (negative affect) resistance strategies to decrease persuasion. The obtained insights do not only advance our theoretical understanding of how disclosures of sponsored blogs affect persuasion but also provide valuable insights for legislators, advertisers, and bloggers. PMID:27721511

  5. Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon.

    PubMed

    Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K

    2011-12-01

    Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.

  6. Development and applicability of a ready-to-use PCR system for GMO screening.

    PubMed

    Rosa, Sabrina F; Gatto, Francesco; Angers-Loustau, Alexandre; Petrillo, Mauro; Kreysa, Joachim; Querci, Maddalena

    2016-06-15

    With the growing number of GMOs introduced to the market, testing laboratories have seen their workload increase significantly. Ready-to-use multi-target PCR-based detection systems, such as pre-spotted plates (PSP), reduce analysis time while increasing capacity. This paper describes the development and applicability to GMO testing of a screening strategy involving a PSP and its associated web-based Decision Support System. The screening PSP was developed to detect all GMOs authorized in the EU in one single PCR experiment, through the combination of 16 validated assays. The screening strategy was successfully challenged in a wide inter-laboratory study on real-life food/feed samples. The positive outcome of this study could result in the adoption of a PSP screening strategy across the EU; a step that would increase harmonization and quality of GMO testing in the EU. Furthermore, this system could represent a model for other official control areas where high-throughput DNA-based detection systems are needed. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Computer-aided dispatch--traffic management center field operational test : state of Utah final report

    DOT National Transportation Integrated Search

    2006-07-01

    This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...

  8. Intra- and inter-laboratory reliability of a cryopreserved trout hepatocyte assay for the prediction of chemical bioaccumulation potential

    EPA Science Inventory

    Cryopreserved trout hepatocytes provide a convenient in vitro system for measuring the intrinsic clearance of xenobiotics. Measured clearance rates can then be extrapolated to the whole animal as a means of improving modeled bioaccumulation predictions. To date, however, the in...

  9. Evaluation of Methods for Analysis of Lead in Air Particulates: An Intra-Laboratory and Inter-Laboratory Comparison

    EPA Science Inventory

    In 2008, the United States Environmental Protection Agency (USEPA) set a new National Ambient Air Quality Standard (NAAQS) for lead (Pb) in total suspended particulate matter (Pb-TSP) which called for significant decreases in the allowable limits. The Federal Reference Method (FR...

  10. Evaluation of the repeatability and reproducibility of a suite of qPCR based microbial source tracking methods

    EPA Science Inventory

    Many PCR-based methods for microbial source tracking (MST) have been developed and validated within individual research laboratories. Inter-laboratory validation of these methods, however, has been minimal, and the effects of protocol standardization regimes have not been thor...

  11. Inter-laboratory Comparison of Real-time PCR Methods for Quantification of General Fecal Indicator Bacteria

    EPA Science Inventory

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized prot...

  12. Interlaboratory Comparison of Real-time PCR Protocols for Quantification of General Fecal Indicator Bacteria

    EPA Science Inventory

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized proto...

  13. An interlaboratory study measuring sex steroids with RIAs and/or ELISAs: Are we comparing apples to oranges?

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs) are exogenous substances released into the environment that can lead to adverse reproductive effects in fish by a number of mechanisms including altering circulating levels of estradiol (E2), testosterone (T) and 11-ketotestosterone (11KT). ...

  14. AN INTERLABORATORY STUDY ON THE USE OF STEROID HORMONES IN EVALUATING ENDOCRINE DISRUPTION

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among a...

  15. INTERLABORATORY STUDY ON THE USE OF STEROID HORMONES IN EXAMINING ENDOCRINE DISRUPTION.

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among ...

  16. AN INTERLABORATORY STUDY ON THE USE OF STERIOD HORMONES IN EXAMINING ENDOCRINE DISRUPTION.

    EPA Science Inventory

    In recent years, there has been an increased use of the measurement of sex steroid hormone levels in the blood of animals exposed to chemicals as an indicator of reproductive impairment or an alteration in endocrine function. Although levels of hormones are often compared among a...

  17. In vitro to In vivo extrapolation of hepatic metabolism in fish: An inter-laboratory comparison of In vitro methods

    EPA Science Inventory

    Chemical biotransformation represents the single largest source of uncertainty in chemical bioaccumulation assessments for fish. In vitro methods employing isolated hepatocytes and liver subcellular fractions (S9) can be used to estimate whole-body rates of chemical metabolism, ...

  18. Touryan Elected Chairman

    Science.gov Websites

    Touryan Elected Chairman of Proliferation Prevention Advisory Board For information contact: e:mail ) National Renewable Energy Laboratory (NREL) was elected chairman of the Inter-Laboratory Advisory Board for opportunities and a means of rapid commercialization of defense technologies. It creates a win-win situation for

  19. INTERLABORATORY VALIDATION OF USEPA METHOD 1680: FECAL COLIFORMS IN BIOSOLIDS BY MULTIPLE-TUBE FERMENTATION PROCEDURES

    EPA Science Inventory

    In the US, the use and disposal of biosolids (including domestic septage) are regulated under 40 CFR Part 503. Subpart D of this regulation protects public health and the environment through requirements designed to reduce the potential for contact with pathogens in biosolids app...

  20. INTERLABORATORY VALIDATION OF USEPA METHOD 1680: FECAL COLIFORMS IN BIOSOLIDS BY MULTIPLE-TUBE FERMENTATION PROCEDURES

    EPA Science Inventory

    In the United States, the use and disposal of biosolids (including domestic septage) are regulated under 40 CFR Part 503. Subpart D of this regulation protects public health and the environment through requirements designed to reduce the potential for contact with pathogens in bi...

  1. How consistent are we? Inter-laboratory comparison for male fathead minnows exposed to 17α-ethinylestradiol

    EPA Science Inventory

    Transcriptomic approaches are widely used to examine effects of aquatic contaminants in both laboratory and field studies. Fundamental questions remain however for defining the limits of the technology and how it may be used in environmental monitoring programs. Uncertainties exi...

  2. INTERLABORATORY COMPARISON STUDIES FOR CHARACTERIZATION OF ORGANIC COMPOUNDS IN PARTICULATE MATTER

    EPA Science Inventory

    A working group of investigators, who are characterizing and quantifying the organic compounds in particulate matter (PM) as part of the US EPA's PM 2.5 research program and related studies, was established three years ago to advance the quality and comparability of data on the...

  3. Measurements of gamma (γ)-emitting radionuclides with a high-purity germanium detector: the methods and reliability of our environmental assessments on the Fukushima 1 Nuclear Power Plant accident.

    PubMed

    Mimura, Tetsuro; Mimura, Mari; Komiyama, Chiyo; Miyamoto, Masaaki; Kitamura, Akira

    2014-01-01

    The severe accident of Fukushima 1 Nuclear Power Plant due to the Tohoku Region Pacific Coast Earthquake in 11 March 2011 caused wide contamination and pollution by radionuclides in Fukushima and surrounding prefectures. In the current JPR symposium, a group of plant scientists attempted to examine the impact of the radioactive contamination on wild and cultivated plants. Measurements of gamma (γ) radiation from radionuclides in "Fukushima samples", which we called and collected from natural and agricultural areas in Fukushima prefecture were mostly done with a high-purity Ge detector in the Graduate School of Maritime Sciences, Kobe University. In this technical note, we describe the methods of sample preparation and measurements of radioactivity of the samples and discuss the reliability of our data in regards to the International Atomic Energy Agency (IAEA) Interlaboratory comparisons and proficiency test (IAEA proficiency test).

  4. Extrapolating Accelerated UV Weathering Data: Perspective From PVQAT Task Group 5 (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Annigoni, E.; Ballion, A.

    2015-02-01

    Taskgroup 5 (TG5) is concerned with a accelerated aging standard incorporating factors including ultraviolet radiation, temperature, and moisture. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for the TG5 interlaboratory study being directed out of the USA. Qualitative preliminary data from the experiment is presented. To date, the encapsulation transmittance experiment has: replicated behaviors of fielded materials (including specimen location- and formulation additive-specific discoloration); demonstrated coupling between UV aging and temperature; demonstrated that degradation in EVA results frommore » UV- aging; and obtained good qualitative comparison between Xe and UVA-340 sources for EVA. To date, the encapsulation adhesion experiment (using the compressive shear test to quantify strength of attachment) has demonstrated that attachment strength can decrease drastically (>50%) with age; however, early results suggest significant factor (UV, T, RH) dependence. Much remains to be learned about adhesion.« less

  5. Differences in results of analyses of concurrent and split stream-water samples collected and analyzed by the US Geological Survey and the Illinois Environmental Protection Agency, 1985-91

    USGS Publications Warehouse

    Melching, C.S.; Coupe, R.H.

    1995-01-01

    During water years 1985-91, the U.S. Geological Survey (USGS) and the Illinois Environmental Protection Agency (IEPA) cooperated in the collection and analysis of concurrent and split stream-water samples from selected sites in Illinois. Concurrent samples were collected independently by field personnel from each agency at the same time and sent to the IEPA laboratory, whereas the split samples were collected by USGS field personnel and divided into aliquots that were sent to each agency's laboratory for analysis. The water-quality data from these programs were examined by means of the Wilcoxon signed ranks test to identify statistically significant differences between results of the USGS and IEPA analyses. The data sets for constituents and properties identified by the Wilcoxon test as having significant differences were further examined by use of the paired t-test, mean relative percentage difference, and scattergrams to determine if the differences were important. Of the 63 constituents and properties in the concurrent-sample analysis, differences in only 2 (pH and ammonia) were statistically significant and large enough to concern water-quality engineers and planners. Of the 27 constituents and properties in the split-sample analysis, differences in 9 (turbidity, dissolved potassium, ammonia, total phosphorus, dissolved aluminum, dissolved barium, dissolved iron, dissolved manganese, and dissolved nickel) were statistically significant and large enough to con- cern water-quality engineers and planners. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between paris of split samples were compared to the precision of the laboratory method used and the interlaboratory precision of measuring a given concentration or property. Consideration of method precision indicated that differences between concurrent samples were insignificant for all concentrations and properties except pH, and that differences between split samples were significant for all concentrations and properties. Consideration of interlaboratory precision indicated that the differences between the split samples were not unusually large. The results for the split samples illustrate the difficulty in obtaining comparable and accurate water-quality data.

  6. Phillips Laboratory small satellite initiatives

    NASA Astrophysics Data System (ADS)

    Lutey, Mark K.; Imler, Thomas A.; Davis, Robert J.

    1993-09-01

    The Phillips Laboratory Space Experiments Directorate in conjunction with the Air Force Space Test Program (AF STP), Defense Advanced Research and Projects Agency (DARPA) and Strategic Defense Initiative Organization (SDIO), are managing five small satellite program initiatives: Lightweight Exo-Atmospheric Projectile (LEAP) sponsored by SDIO, Miniature Sensor Technology Integration (MSTI) sponsored by SDIO, Technology for Autonomous Operational Survivability (TAOS) sponsored by Phillips Laboratory, TechSat sponsored by SDIO, and the Advanced Technology Standard Satellite Bus (ATSSB) sponsored by DARPA. Each of these spacecraft fulfills a unique set of program requirements. These program requirements range from a short-lived `one-of-a-kind' mission to the robust multi- mission role. Because of these diverging requirements, each program is driven to use a different design philosophy. But regardless of their design, there is the underlying fact that small satellites do not always equate to small missions. These spacecraft with their use of or ability to insert new technologies provide more capabilities and services for their respective payloads which allows the expansion of their mission role. These varying program efforts culminate in an ATSSB spacecraft bus approach that will support moderate size payloads, up to 500 pounds, in a large set of orbits while satisfying the `cheaper, faster, better' method of doing business. This technical paper provides an overview of each of the five spacecraft, focusing on the objectives, payoffs, technologies demonstrated, and program status.

  7. Industry sponsored anti‐smoking ads and adolescent reactance: test of a boomerang effect

    PubMed Central

    Henriksen, L; Dauphinee, A L; Wang, Y; Fortmann, S P

    2006-01-01

    Objective To examine whether adolescents' exposure to youth smoking prevention ads sponsored by tobacco companies promotes intentions to smoke, curiosity about smoking, and positive attitudes toward the tobacco industry. Design A randomised controlled experiment compared adolescents' responses to five smoking prevention ads sponsored by a tobacco company (Philip Morris or Lorillard), or to five smoking prevention ads sponsored by a non‐profit organisation (the American Legacy Foundation), or to five ads about preventing drunk driving. Setting A large public high school in California's central valley. Subjects A convenience sample of 9th and 10th graders (n  =  832) ages 14–17 years. Main outcome measures Perceptions of ad effectiveness, intention to smoke, and attitudes toward tobacco companies measured immediately after exposure. Results As predicted, adolescents rated Philip Morris and Lorillard ads less favourably than the other youth smoking prevention ads. Adolescents' intention to smoke did not differ as a function of ad exposure. However, exposure to Philip Morris and Lorillard ads engendered more favourable attitudes toward tobacco companies. Conclusions This study demonstrates that industry sponsored anti‐smoking ads do more to promote corporate image than to prevent youth smoking. By cultivating public opinion that is more sympathetic toward tobacco companies, the effect of such advertising is likely to be more harmful than helpful to youth. PMID:16436398

  8. KSC01kodi071

    NASA Image and Video Library

    2001-08-08

    KODIAK ISLAND, Alaska -- Technicians transport the Sapphire payload at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5 p.m. to 7 p.m. p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  9. KSC01KODI057

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Technicians prepare the Athena I launch vehicle for flight at Kodiak Island, Alaska, as processing for the launch of Kodiak Star proceeds. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  10. Results of external quality-assurance program for the National Atmospheric Deposition Program and National Trends Network during 1985

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.

    1988-01-01

    External quality assurance monitoring of the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN) was performed by the U.S. Geological Survey during 1985. The monitoring consisted of three primary programs: (1) an intersite comparison program designed to assess the precision and accuracy of onsite pH and specific conductance measurements made by NADP and NTN site operators; (2) a blind audit sample program designed to assess the effect of routine field handling on the precision and bias of NADP and NTN wet deposition data; and (3) an interlaboratory comparison program designed to compare analytical data from the laboratory processing NADP and NTN samples with data produced by other laboratories routinely analyzing wet deposition samples and to provide estimates of individual laboratory precision. An average of 94% of the site operators participated in the four voluntary intersite comparisons during 1985. A larger percentage of participating site operators met the accuracy goal for specific conductance measurements (average, 87%) than for pH measurements (average, 67%). Overall precision was dependent on the actual specific conductance of the test solution and independent of the pH of the test solution. Data for the blind audit sample program indicated slight positive biases resulting from routine field handling for all analytes except specific conductance. These biases were not large enough to be significant for most data users. Data for the blind audit sample program also indicated that decreases in hydrogen ion concentration were accompanied by decreases in specific conductance. Precision estimates derived from the blind audit sample program indicate that the major source of uncertainty in wet deposition data is the routine field handling that each wet deposition sample receives. Results of the interlaboratory comparison program were similar to results of previous years ' evaluations, indicating that the participating laboratories produced comparable data when they analyzed identical wet deposition samples, and that the laboratory processing NADP and NTN samples achieved the best analyte precision of the participating laboratories. (Author 's abstract)

  11. Optimisation of an analytical method and results from the inter-laboratory comparison of the migration of regulated substances from food packaging into the new mandatory European Union simulant for dry foodstuffs.

    PubMed

    Jakubowska, Natalia; Beldì, Giorgia; Peychès Bach, Aurélie; Simoneau, Catherine

    2014-01-01

    This paper presents the outcome of the development, optimisation and validation at European Union level of an analytical method for using poly(2,6-diphenyl phenylene oxide--PPPO), which is stipulated in Regulation (EU) No. 10/2011, as food simulant E for testing specific migration from plastics into dry foodstuffs. Two methods for fortifying respectively PPPO and a low-density polyethylene (LDPE) film with surrogate substances that are relevant to food contact were developed. A protocol for cleaning the PPPO and an efficient analytical method were developed for the quantification of butylhydroxytoluene (BHT), benzophenone (BP), diisobutylphthalate (DiBP), bis(2-ethylhexyl) adipate (DEHA) and 1,2-cyclohexanedicarboxylic acid, diisononyl ester (DINCH) from PPPO. A protocol for a migration test from plastics using small migration cells was also developed. The method was validated by an inter-laboratory comparison (ILC) with 16 national reference laboratories for food contact materials in the European Union. This allowed for the first time data to be obtained on the precision and laboratory performance of both migration and quantification. The results showed that the validation ILC was successful even when taking into account the complexity of the exercise. The results showed that the method performance was 7-9% repeatability standard deviation (rSD) for most substances (regardless of concentration), with 12% rSD for the high level of BHT and for DiBP at very low levels. The reproducibility standard deviation results for the 16 European Union laboratories were in the range of 20-30% for the quantification from PPPO (for the three levels of concentrations of the five substances) and 15-40% from migration experiments from the fortified plastic at 60°C for 10 days and subsequent quantification. Considering the lack of data previously available in the literature, this work has demonstrated that the validation of a method is possible both for migration from a film and for quantification into a corresponding simulant for specific migration.

  12. Development of Micro-Electrode Array Based Tests for Neurotoxicity: Assessment of Interlaboratory Reproducibility with Neuroactive Chemicals

    PubMed Central

    Novellino, A.; Scelfo, Bibiana; Palosaari, T.; Price, A.; Sobanski, Tomasz; Shafer, T. J.; Johnstone, A. F. M.; Gross, G. W.; Gramowski, A.; Schroeder, O.; Jügelt, K.; Chiappalone, M.; Benfenati, F.; Martinoia, S.; Tedesco, M. T.; Defranchi, E.; D’Angelo, P.; Whelan, M.

    2011-01-01

    Neuronal assemblies within the nervous system produce electrical activity that can be recorded in terms of action potential patterns. Such patterns provide a sensitive endpoint to detect effects of a variety of chemical and physical perturbations. They are a function of synaptic changes and do not necessarily involve structural alterations. In vitro neuronal networks (NNs) grown on micro-electrode arrays (MEAs) respond to neuroactive substances as well as the in vivo brain. As such, they constitute a valuable tool for investigating changes in the electrophysiological activity of the neurons in response to chemical exposures. However, the reproducibility of NN responses to chemical exposure has not been systematically documented. To this purpose six independent laboratories (in Europe and in USA) evaluated the response to the same pharmacological compounds (Fluoxetine, Muscimol, and Verapamil) in primary neuronal cultures. Common standardization principles and acceptance criteria for the quality of the cultures have been established to compare the obtained results. These studies involved more than 100 experiments before the final conclusions have been drawn that MEA technology has a potential for standard in vitro neurotoxicity/neuropharmacology evaluation. The obtained results show good intra- and inter-laboratory reproducibility of the responses. The consistent inhibitory effects of the compounds were observed in all the laboratories with the 50% Inhibiting Concentrations (IC50s) ranging from: (mean ± SEM, in μM) 1.53 ± 0.17 to 5.4 ± 0.7 (n = 35) for Fluoxetine, 0.16 ± 0.03 to 0.38 ± 0.16 μM (n = 35) for Muscimol, and 2.68 ± 0.32 to 5.23 ± 1.7 (n = 32) for Verapamil. The outcome of this study indicates that the MEA approach is a robust tool leading to reproducible results. The future direction will be to extend the set of testing compounds and to propose the MEA approach as a standard screen for identification and prioritization of chemicals with neurotoxicity potential. PMID:21562604

  13. 10 CFR 950.21 - Notification of covered event.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... event; (2) The duration of the delay in the schedule for construction, testing and full power operation... and full power operation, including the dates of system level construction or testing that had been... information is accurate and complete to the sponsor's knowledge and belief. ...

  14. Evaluation of the Anaheim Advanced Traffic Control System Field Operational Test : Task B : assessment of institutional issues

    DOT National Transportation Integrated Search

    1999-07-01

    This report provides an overview of the technical and institutional issues associated with the : evaluation of the federally-sponsored Anaheim Advanced Traffic Control System Field Operations Test. The primary FOT objective was the implementation and...

  15. European Proficiency testing of national reference laboratories for the confirmation of sulfonamide residues in muscle and milk.

    PubMed

    Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal

    2005-03-01

    Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.

  16. Measurement of the setting expansion of phosphate-bonded investment materials: Part I - Development of the Casting-Ring Test.

    PubMed

    Lloyd, C H; Yearn, J A; Cowper, G A; Blavier, J; Vanderdonckt, M

    2004-07-01

    The setting expansion is an important property for a phosphate-bonded investment material. This research was undertaken to investigate a test that might be suitable for its measurement when used in a Standard. In the 'Casting-Ring Test', the investment sample is contained in a steel ring and expands to displace a precisely positioned pin. Variables with the potential to alter routine reproduction of the value were investigated. The vacuum-mixer model is a production laboratory variable that must not be ignored and for this reason, experiments were repeated using a different vacuum-mixer located at a second test site. Restraint by the rigid ring material increased expansion, while force on the pin reduced it. Expansion was specific to the lining selected. Increased environmental temperature decreased the final value. Expansion was still taking place at a time at which its value might be measured. However, when these factors are set, the reproducibility of values for setting expansion was good at both test sites (coefficient of variation 14%, at most). The results revealed that with the control that is available reliable routine measurement is possible in a Standard test. The inter-laboratory variable, vacuum-mixer model, produced significant differences and it should be the subject of further investigation.

  17. KSC-00pp0330

    NASA Image and Video Library

    2000-03-10

    The Bee Bots team (393) robot, named Dr. Beevil, scores by gathering balls. The team is composed of students from Morristown Jr. and Sr. high schools in Morristown, Ind., and is co-sponsored by NASA Kennedy Space Center and IPT Inc. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  18. Team 393 robot scores in FIRST competition

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Bee Bots team (393) robot, named Dr. Beevil, scores by gathering balls. The team is composed of students from Morristown Jr. and Sr. high schools in Morristown, Ind., and is co-sponsored by NASA Kennedy Space Center and IPT Inc. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville.

  19. KSC00pp0330

    NASA Image and Video Library

    2000-03-10

    The Bee Bots team (393) robot, named Dr. Beevil, scores by gathering balls. The team is composed of students from Morristown Jr. and Sr. high schools in Morristown, Ind., and is co-sponsored by NASA Kennedy Space Center and IPT Inc. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  20. KSC-00pp0334

    NASA Image and Video Library

    2000-03-10

    The Hero Team (278) gets some help from a Kennedy Space Center research and development machine shop in repairing their robot, named Hero. The team of Edgewater High School students was co-sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  1. KSC00pp0326

    NASA Image and Video Library

    2000-03-10

    The Roboticks team (408) carries their robot, which is named R2K, during the FIRST competition. The team of students from Blanche Ely High School in Ft. Lauderdale was co-sponsored by Nortel Networks and NASA Kennedy Space Center. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  2. KSC-00pp0326

    NASA Image and Video Library

    2000-03-10

    The Roboticks team (408) carries their robot, which is named R2K, during the FIRST competition. The team of students from Blanche Ely High School in Ft. Lauderdale was co-sponsored by Nortel Networks and NASA Kennedy Space Center. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville

  3. NASA/DoD Aerospace knowledge diffusion research project. III - The impact of a sponsor letter on mail survey response rates

    NASA Technical Reports Server (NTRS)

    Kennedy, John M.; Pinelli, Thomas E.

    1990-01-01

    The paper describes the impact of two interventions in the design of mail surveys. The interventions were devised to increase response rates and to clarify sample eligibility. To test their effectiveness, interventions occurred at different points in each of three surveys. One intervention was a letter from the research sponsor (NASA) supporting the research. The other intervention was the inclusion of a postcard that could be used by the respondent to indicate that the questionnaire was not appropriate for him/her. The sample was drawn from the membership of the American Institute for Aeronautics and Astronautics research society. The results indicate that the sponsor letter improved response rates under certain conditions described in the paper. The postcards assisted in identifying noneligible persons particularly when they accompanied a pre-survey letter. The implications for survey costs are discussed.

  4. KSC00pp0325

    NASA Image and Video Library

    2000-03-10

    The Orange Crusher team (282) works on their robot, which is named Rust Bot, during the FIRST competition. The team of students from Lake Howell, Winter Springs and Orange Christian Private high schools was co-sponsored by NASA Kennedy Space Center, Matern Professional Engineering The Foundation, Control Technologies, Lucent Technologies and Sandy Engineering. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusvill

  5. KSC-00pp0325

    NASA Image and Video Library

    2000-03-10

    The Orange Crusher team (282) works on their robot, which is named Rust Bot, during the FIRST competition. The team of students from Lake Howell, Winter Springs and Orange Christian Private high schools was co-sponsored by NASA Kennedy Space Center, Matern Professional Engineering The Foundation, Control Technologies, Lucent Technologies and Sandy Engineering. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusvill

  6. Team 278 gets help from KSC machine shop

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Hero Team (278) gets some help from a Kennedy Space Center research and development machine shop in repairing their robot, named Hero. The team of Edgewater High School students was co- sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co- sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville.

  7. Team 278 gets help from KSC machine shop

    NASA Technical Reports Server (NTRS)

    2000-01-01

    The Hero Team (278) robot, named Hero, is repaired in a Kennedy Space Center research and development machine shop. The team of Edgewater High School students was co-sponsored by NASA Kennedy Space Center and Honeywell. Students from all over the country are at the KSC Visitor Complex for the FIRST (For Inspiration and Recognition of Science and Technology) Southeast Regional competition March 9-11 in the Rocket Garden. Teams of high school students are testing the limits of their imagination using robots they have designed, with the support of business and engineering professionals and corporate sponsors, to compete in a technological battle against other schools' robots. Of the 30 high school teams competing, 16 are Florida teams co-sponsored by NASA and KSC contractors. Local high schools participating are Astronaut, Bayside, Cocoa Beach, Eau Gallie, Melbourne, Melbourne Central Catholic, Palm Bay, Rockledge, Satellite, and Titusville.

  8. Occupant Protection Experiments in Support of a Full-scale Train-to-Train Crash Energy Management Equipment Collision Test

    DOT National Transportation Integrated Search

    2009-07-31

    The Federal Railroad Administration sponsored a full-scale train-to-train crash energy management (CEM) technology test that was conducted on March 23, 2006, at the Transportation Technology Center in Pueblo, Colorado. The Volpe National Transportati...

  9. Traffic control device evaluation program: simulator evaluation of sponsored changeable message signs and in-situ evaluation of rumble strip alternatives.

    DOT National Transportation Integrated Search

    2016-07-01

    This report describes two research activities. One research study tested the effects of adding commercial : logos acknowledging sponsorship to Changeable Message Signs. A driving simulator study was conducted : using test signs with travel times and ...

  10. Speaking Out: The Use of Tests in the Policy Arena. Proceedings of the New Jersey Conference.

    ERIC Educational Resources Information Center

    Educational Testing Service, Washington, DC. Education Policy Research Inst.

    In February, 1976, the Education Policy Research Institute sponsored this conference on the use of tests in educational policy formation; these six papers were presented at that conference. In the first paper, Jenne K. Britell discusses four points that have historically characterized debates about testing; psychometric and technical issues;…

  11. Rheology measurements of a biomass slurry : an inter-laboratory study

    Treesearch

    Jonathan J. Stickel; Jeffrey S. Knutsen; Matthew W. Liberatore; Wing Luu; Douglas W. Bousfield; Daniel J. Klingenberg; Tim Scott; Thatcher W. Root; Max R. Ehrhardt; Thomas O. Monz

    2009-01-01

    The conversion of biomass, specifically lignocellulosic biomass, into fuels and chemicals has recently gained national attention as an alternative to the use of fossil fuels. Increasing the concentration of the biomass solids during biochemical conversion has a large potential to reduce production costs. These concentrated biomass slurries have highly viscous, non-...

  12. Performance of the Cottonscan Instrument for Measuring the Average Fiber Linear Density (Fineness) of Cotton Lint Samples

    USDA-ARS?s Scientific Manuscript database

    This paper explores the CottonscanTM instrument, a new technology designed for routine measurement of the average linear density (fineness) of cotton fiber. A major international inter-laboratory trial of the CottonscanTM system is presented. This expands the range of cottons and laboratories fro...

  13. COMPARISON AND EVALUATION OF LABORATORY PERFORMANCE ON A METHOD FOR THE DETERMINATION OF PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    This report details the interlaboratory validation of a method for the determination of perchlorate in fertilizers. In this method (EPA/600/R-01/026), a solid sample of fertilizer is first ground. subsequently, the ground material is either leached with deionized water to dissolv...

  14. OVERVIEW OF AN INTERLABORATORY COLLABORATION ON EVALUATING THE EFFECTS OF MODEL HEPATOTOXICANTS ON HEPATIC GENE EXPRESSION

    EPA Science Inventory

    Evaluating the Effects of Methapyrilene and Clofibrate on Hepatic Gene Expression: A Collaboration Between Laboratories and a Comparison of Platform and Analytical Approaches

    Roger G. Ulrich1, John C. Rockett2, G. Gordon Gibson3 and Syril Pettit4

    1 Rosetta Inpharmat...

  15. POSSIBLE APPROACHES FOR THE ESTABLISHMENT OF INTERLABORATORY COMPARABILITY IN THE DETERMINATION OF POLYCHLORINATED BIPHENYLS IN HUMAN SERUM

    EPA Science Inventory

    The Massachusetts Department of Public Health, with the assistance of the centers for Disease Control, conducted a study to determine the prevalence of elevated levels (>30ppb) of polychlorinated biphenyls (PCBs) in serum taken from residents of the greater New Bedford area in Ma...

  16. CHARACTERIZATION OF FINE PARTICLE ASSOCIATED ORGANIC COMPOUNDS: INTERLABORATORY COMPARISON AND DEVELOPMENT OF STANDARD REFERENCE MATERIALS

    EPA Science Inventory

    Organic chemicals adsorbed to fine particulate matter (PM) in the ambient air account for a major component of the mass and include source tracers as well as toxic compounds that may contribute to adverse human health effects. The US EPA has established a PM 2.5 research progr...

  17. Validation of standard method EN ISO 11290-part 2 for the enumeration of Listeria monocytogenes in food.

    PubMed

    Rollier, Patricia; Lombard, Bertrand; Guillier, Laurent; François, Danièle; Romero, Karol; Pierru, Sylvie; Bouhier, Laurence; Gnanou Besse, Nathalie

    2018-05-01

    The reference method for the detection and enumeration of L. monocytogenes in food (Standards EN ISO 11290-1&2) have been validated by inter-laboratory studies in the frame of the Mandate M381 from European Commission to CEN. In this paper, the inter-laboratory studies led in 2013 on 5 matrices (cold-smoked salmon, milk powdered infant food formula, vegetables, environment, and cheese) to validate Standard EN ISO 11290-2 are reported. According to the results obtained, the method of the revised Standard EN ISO 11290-2 can be considered as a good method for the enumeration of L. monocytogenes in foods and food processing environment, in particular for the matrices included in the study. Values of repeatability and reproducibility standard deviations can be considered satisfactory for this type of method with a confirmation stage, since most of them were below 0.3 log 10 , also at low levels, close to the regulatory limit of 100 CFU/g. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Mutagencity Testing of WR238605 Succinate

    DTIC Science & Technology

    1996-05-03

    control article have not been determined by the testing facility. The stability of the test or control article under the test conditions has not been...determined by the testing facility and is not included in the final report. Analyses to determine the uniformity, concentration, or stability of the...fraction. Aliquots of the dosing solutions have been retained by MA. The Sponsor has assumed responsibility for the determination of the stability

  19. Probability-Based Inference in a Domain of Proportional Reasoning Tasks

    DTIC Science & Technology

    1992-01-01

    Embretson, S.E. (1985). Multicomponent latent trait models for test design. In SE. Embretson (Ed.), Test design: Developments in psychology and...J.C. Conoley, & J. Witt (Eds.), The influence of cognitive psychology on testing and measurement: The Buros-Nebraska Symposium on measurement and...Mislevy Educational Testing Service This research was sponsored in part by the Cognitive Science Program Cognitive and Neural Sciences Division Office of

  20. Highway concrete pavement technology development and testing : volume III, field evaluation of Strategic Highway Research Program (SHRP) C-205 test sites (high-performance concrete).

    DOT National Transportation Integrated Search

    2006-05-01

    This research study, sponsored by the Federal Highway Administration, summarizes the field performance of eight high-early-strength (HES) : concrete patches between 1994 and 1998. The patches were constructed under the Strategic Highway Research Prog...

  1. Minorities and Women in Educational Research: Progress Toward Equality. Final Report.

    ERIC Educational Resources Information Center

    American Educational Research Association, Washington, DC.

    This report evaluates a project to pilot-test workshop materials designed to facilitate increased participation of women and minorities in educational research and development. The pilot test involved three NIE/AERA sponsored workshops organized in conjunction with the 1980 annual meeting of the American Educational Research Association. The…

  2. 21 CFR 58.215 - Alternative or additional actions to disqualification.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing... against a testing facility and/or against the sponsor of a nonclinical laboratory study that has been... nonclinical laboratory study in support of an application for a research or marketing permit, if it finds that...

  3. 21 CFR 58.215 - Alternative or additional actions to disqualification.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Disqualification of Testing... against a testing facility and/or against the sponsor of a nonclinical laboratory study that has been... nonclinical laboratory study in support of an application for a research or marketing permit, if it finds that...

  4. Some Current Problems in Simulator Design, Testing and Use.

    ERIC Educational Resources Information Center

    Caro, Paul W.

    Concerned with the general problem of the effectiveness of simulator training, this report reflects information developed during the conduct of aircraft simulator training research projects sponsored by the Air Force, Army, Navy, and Coast Guard. Problems are identified related to simulator design, testing, and use, all of which impact upon…

  5. Acid-Soluble Internal Capsules for Closed-Face Cassette Elemental Sampling and Analysis of Workplace Air

    PubMed Central

    Harper, Martin; Ashley, Kevin

    2013-01-01

    Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, interlaboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements. PMID:23548078

  6. Trueness and precision of the real-time RT-PCR method for quantifying the chronic bee paralysis virus genome in bee homogenates evaluated by a comparative inter-laboratory study.

    PubMed

    Schurr, Frank; Cougoule, Nicolas; Rivière, Marie-Pierre; Ribière-Chabert, Magali; Achour, Hamid; Ádám, Dán; Castillo, Carlos; de Graaf, Dirk C; Forsgren, Eva; Granato, Anna; Heinikainen, Sirpa; Jurovčíková, Júlia; Kryger, Per; Manson, Christine; Ménard, Marie-Françoise; Perennes, Stéphane; Schäfer, Marc O; Ibañez, Elena San Miguel; Silva, João; Gajger, Ivana Tlak; Tomkies, Victoria; Toplak, Ivan; Viry, Alain; Zdańska, Dagmara; Dubois, Eric

    2017-10-01

    The Chronic bee paralysis virus (CBPV) is the aetiological agent of chronic bee paralysis, a contagious disease associated with nervous disorders in adult honeybees leading to massive mortalities in front of the hives. Some of the clinical signs frequently reported, such as trembling, may be confused with intoxication syndromes. Therefore, laboratory diagnosis using real-time PCR to quantify CBPV loads is used to confirm disease. Clinical signs of chronic paralysis are usually associated with viral loads higher than 10 8 copies of CBPV genome copies per bee (8 log 10 CBPV/bee). This threshold is used by the European Union Reference Laboratory for Bee Health to diagnose the disease. In 2015, the accuracy of measurements of three CBPV loads (5, 8 and 9 log 10 CBPV/bee) was assessed through an inter-laboratory study. Twenty-one participants, including 16 European National Reference Laboratories, received 13 homogenates of CBPV-infected bees adjusted to the three loads. Participants were requested to use the method usually employed for routine diagnosis. The quantitative results (n=270) were analysed according to international standards NF ISO 13528 (2015) and NF ISO 5725-2 (1994). The standard deviations of measurement reproducibility (S R ) were 0.83, 1.06 and 1.16 at viral loads 5, 8 and 9 log 10 CBPV/bee, respectively. The inter-laboratory confidence of viral quantification (+/- 1.96S R ) at the diagnostic threshold (8 log 10 CBPV/bee) was+/- 2.08 log 10 CBPV/bee. These results highlight the need to take into account the confidence of measurements in epidemiological studies using results from different laboratories. Considering this confidence, viral loads over 6 log 10 CBPV/bee may be considered to indicate probable cases of chronic paralysis. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  8. Inter-laboratory quality control for hormone-dependent gene expression in human breast tumors using real-time reverse transcription-polymerase chain reaction.

    PubMed

    de Cremoux, P; Bieche, I; Tran-Perennou, C; Vignaud, S; Boudou, E; Asselain, B; Lidereau, R; Magdelénat, H; Becette, V; Sigal-Zafrani, B; Spyratos, F

    2004-09-01

    Quantitative reverse transcription-polymerase chain reaction (RT-PCR) used to detect minor changes in specific mRNA concentrations may be associated with poor reproducibility. Stringent quality control is therefore essential at each step of the protocol, including the PCR procedure. We performed inter-laboratory quality control of quantitative PCR between two independent laboratories, using in-house RT-PCR assays on a series of hormone-related target genes in a retrospective consecutive series of 79 breast tumors. Total RNA was reverse transcribed in a single center. Calibration curves were performed for five target genes (estrogen receptor (ER)alpha, ERbeta, progesterone receptor (PR), CYP19 (aromatase) and Ki 67) and for two reference genes (human acidic ribosomal phosphoprotein PO (RPLPO) and TATA box-binding protein (TBP)). Amplification efficiencies of the calibrator were determined for each run and used to calculate mRNA expression. Correlation coefficients were evaluated for each target and each reference gene. A good correlation was observed for all target and reference genes in both centers using their own protocols and kits (P < 0.0001). The correlation coefficients ranged from 0.90 to 0.98 for the various target genes in the two centers. A good correlation was observed between the level of expression of the ERalpha and the PR transcripts (P < 0.001). A weak inverse correlation was observed in both centers between ERalpha and ERbeta levels, but only when TBP was the reference gene. No other correlation was observed with other parameters. Real-time PCR assays allow convenient quantification of target mRNA transcripts and quantification of target-derived nucleic acids in clinical specimens. This study addresses the importance of inter-laboratory quality controls for the use of a panel of real-time PCR assays devoted to clinical samples and protocols and to ensure their appropriate accuracy. This can also facilitate exchanges and multicenter comparison of data.

  9. Repeatability and Reproducibility of Compression Strength Measurements Conducted According to ASTM E9

    NASA Technical Reports Server (NTRS)

    Luecke, William E.; Ma, Li; Graham, Stephen M.; Adler, Matthew A.

    2010-01-01

    Ten commercial laboratories participated in an interlaboratory study to establish the repeatability and reproducibility of compression strength tests conducted according to ASTM International Standard Test Method E9. The test employed a cylindrical aluminum AA2024-T351 test specimen. Participants measured elastic modulus and 0.2 % offset yield strength, YS(0.2 % offset), using an extensometer attached to the specimen. The repeatability and reproducibility of the yield strength measurement, expressed as coefficient of variations were cv(sub r)= 0.011 and cv(sub R)= 0.020 The reproducibility of the test across the laboratories was among the best that has been reported for uniaxial tests. The reported data indicated that using diametrically opposed extensometers, instead of a single extensometer doubled the precision of the test method. Laboratories that did not lubricate the ends of the specimen measured yield stresses and elastic moduli that were smaller than those measured in laboratories that lubricated the specimen ends. A finite element analysis of the test specimen deformation for frictionless and perfect friction could not explain the discrepancy, however. The modulus measured from stress-strain data were reanalyzed using a technique that finds the optimal fit range, and applies several quality checks to the data. The error in modulus measurements from stress-strain curves generally increased as the fit range decreased to less than 40 % of the stress range.

  10. KSC01kodi066

    NASA Image and Video Library

    2001-08-09

    KODIAK ISLAND, Alaska -- The PICSat and Starshine 3 (back) payloads wait for their launch aboard the Athena 1 launch vehicle at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5 p.m. to 7 p.m. p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  11. KSC01KODI040

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Castor 120, the first stage of the Athena 1 launch vehicle, is raised off a truck at the launch pad at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  12. KSC01kodi063

    NASA Image and Video Library

    2001-08-09

    KODIAK ISLAND, Alaska -- The PCSat payload waits for its launch aboard the Athena 1 launch vehicle at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5 p.m. to 7 p.m. p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  13. KSC01kodi072

    NASA Image and Video Library

    2001-08-08

    KODIAK ISLAND, Alaska -- The Sapphire payload is moved into position next to the Starshine 3 payload at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5 p.m. to 7 p.m. p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  14. KSC01kodi059

    NASA Image and Video Library

    2001-07-31

    KODIAK ISLAND, Alaska -- Technicians prepare the Starshine 3 payload for its launch aboard the Athena 1 launch vehicle at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  15. KSC01kodi064

    NASA Image and Video Library

    2001-08-09

    KODIAK ISLAND, Alaska -- Technicians prepare the PICSat payload for its launch aboard the Athena 1 launch vehicle at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5 p.m. to 7 p.m. p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  16. KSC01KODI046

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Technicians install Orbis 21D Equipment Section Boost Motor, the second stage of the Athena 1 launch vehicle, at Kodiak Island, Alaska, as processing for the launch of Kodiak Star proceeds. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  17. KSC01kodi062

    NASA Image and Video Library

    2001-07-31

    KODIAK ISLAND, Alaska -- Technicians prepare the Starshine 3 payload, while the payload fairing of the Athena 1 launch vehicle awaits servicing at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program

  18. KSC01KODI043

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Castor 120, the first stage of the Athena 1 launch vehicle, is lowered into place at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  19. KSC01KODI039

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Trucks transporting Orbis 21D Equipment Section Boost Motor, the second stage of the Athena 1 launch vehicle, arrive at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  20. KSC01KODI055

    NASA Image and Video Library

    2001-05-29

    KODIAK ISLAND, Alaska -- A convoy of trucks transports the stages of an Athena launch vehicle and supporting launch equipment to the pad at Kodiak Island, Alaska, as preparations to launch the Kodiak Star continue. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  1. KSC01KODI042

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Castor 120, the first stage of the Athena 1 launch vehicle, is lifted into a vertical position at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  2. KSC01KODI041

    NASA Image and Video Library

    2001-05-31

    KODIAK ISLAND, Alaska -- Technicians inspect Castor 120, the first stage of the Athena 1 launch vehicle, at Kodiak Island, Alaska, as preparations to launch Kodiak Star proceed. The first orbital launch to take place from Alaska's Kodiak Launch Complex, Kodiak Star is scheduled to lift off on a Lockheed Martin Athena I launch vehicle on Sept. 17 during a two-hour window that extends from 5:00 to 7:00 p.m. ADT. The payloads aboard include the Starshine 3, sponsored by NASA, and the PICOSat, PCSat and Sapphire, sponsored by the Department of Defense (DoD) Space Test Program.

  3. ORANGES evaluation test plans : analysis of before data collected for the US DOT sponsored evaluation of the ORANGES electronic payment systems field operational test

    DOT National Transportation Integrated Search

    2003-10-02

    This document is one of a series of working papers that report on progress for the US DOT evaluation for Phase I of the ORANGES field operational test. Each working paper corresponds to a Phase I task. At the conclusion of Phase I, these documents wi...

  4. Standard reference material for Her2 testing: report of a National Institute of Standards and Technology-sponsored Consensus Workshop.

    PubMed

    Hammond, M Elizabeth H; Barker, Peter; Taube, Sheila; Gutman, Steven

    2003-06-01

    A workshop was sponsored by the National Institute of Standards and Technology, the Cancer Diagnosis Program of the National Cancer Institute, the Food and Drug Administration, and the College of American Pathologists to address the need for a reference material for Her2 gene protein testing. It was agreed that such a standard was desirable and necessary to ensure the reliability of Her2 testing to qualify patients for trastuzumab therapy. Two standards consisting of well characterized cell lines will be produced, 1 that will be a National Institute of Standards and Technology-certifiable standard, and 1 that will be a commercially developed standard for use in all Her2 testing. It was also agreed that all Her2 testing must be performed on samples fixed only in 10% buffered formalin, as specified in the Food and Drug Administration-approved testing methods. Participants agreed to plan strategies to educate pathologists, clinicians, and laboratories about the need and use of such a standard. A National Committee for Clinical Laboratory Standards guideline for the use of the standard reference material will be created to facilitate this process.

  5. 7 CFR 654.11 - Sponsor(s)' responsibility.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) shall obtain NRCS approval before modifying a project measure of changing land use to fulfill a... § 654.11 Sponsor(s)' responsibility. (a) On non-Federal land, sponsor(s) are responsible for financing... land involving project measures is responsible either for performing or requiring the performance of O...

  6. Acupuncture (PDQ)

    MedlinePlus

    ... patients who were waiting to receive treatment later. Observational studies have also reported both real acupuncture and ... NCCIH) are sponsoring a number of clinical trials (research studies) at ... and alternative methods. Few CAM therapies have been tested using demanding ...

  7. 18 CFR 806.11 - Preliminary consultations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... proposed project, a map showing its location and, to the extent available, data concerning dimensions of... consultation is optional for the project sponsor (except with respect to aquifer test plans, see § 806.12 but...

  8. 21 CFR 58.217 - Suspension or termination of a testing facility by a sponsor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES... further participation in a nonclinical laboratory study that is being conducted as part of any application...

  9. 21 CFR 58.217 - Suspension or termination of a testing facility by a sponsor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AND HUMAN SERVICES GENERAL GOOD LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES... further participation in a nonclinical laboratory study that is being conducted as part of any application...

  10. 7 CFR 622.10 - Sponsors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS Qualifications § 622.10 Sponsors. (a) Watershed projects are sponsored by one or more local organizations qualifying as sponsors. All watershed plans shall be sponsored...

  11. 7 CFR 622.10 - Sponsors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS Qualifications § 622.10 Sponsors. (a) Watershed projects are sponsored by one or more local organizations qualifying as sponsors. All watershed plans shall be sponsored...

  12. 7 CFR 622.10 - Sponsors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS Qualifications § 622.10 Sponsors. (a) Watershed projects are sponsored by one or more local organizations qualifying as sponsors. All watershed plans shall be sponsored...

  13. 7 CFR 622.10 - Sponsors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... AGRICULTURE WATER RESOURCES WATERSHED PROJECTS Qualifications § 622.10 Sponsors. (a) Watershed projects are sponsored by one or more local organizations qualifying as sponsors. All watershed plans shall be sponsored...

  14. Saccadic Reaction Times in Infants and Adults: Spatiotemporal Factors, Gender, and Interlaboratory Variation

    ERIC Educational Resources Information Center

    Kenward, Ben; Koch, Felix-Sebastian; Forssman, Ida; Brehm, Julia; Tidemann, Linda; Sundqvist, Annette; Marciszkom, Carin; Hermansen, Tone Kristine; Heimann, Mikael; Gredebäck, Gustaf

    2017-01-01

    Saccade latency is widely used across infant psychology to investigate infants' understanding of events. Interpreting particular latency values requires knowledge of standard saccadic RTs, but there is no consensus as to typical values. This study provides standard estimates of infants' (n = 194, ages 9 to 15 months) saccadic RTs under a range of…

  15. An inter-laboratory study on the variability in measured concentrations of 17Beta-estradiol, testosterone and 11-ketotestosterone in white sucker: implications and recommendations

    EPA Science Inventory

    Endocrine-disrupting chemicals (EDCs) are exogenous substances that can lead to impacts on the reproduction of fish sometimes by altering circulating concentrations of 17â-estradiol (E2), testosterone (T) and 11-ketotestosterone (11-KT). Common methods to measure steroids in pla...

  16. 40 CFR Appendix D to Part 136 - Precision and Recovery Statements for Methods for Measuring Metals

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Accuracy Section with the following: Precision and Accuracy An interlaboratory study on metal analyses by... details are found in “USEPA Method Study 7, Analyses for Trace Methods in water by Atomic Absorption... study on metal analyses by this method was conducted by the Quality Assurance Branch (QAB) of the...

  17. College of American Pathologists/American College of Medical Genetics proficiency testing for constitutional cytogenomic microarray analysis.

    PubMed

    Brothman, Arthur R; Dolan, Michelle M; Goodman, Barbara K; Park, Jonathan P; Persons, Diane L; Saxe, Debra F; Tepperberg, James H; Tsuchiya, Karen D; Van Dyke, Daniel L; Wilson, Kathleen S; Wolff, Daynna J; Theil, Karl S

    2011-09-01

    To evaluate the feasibility of administering a newly established proficiency test offered through the College of American Pathologists and the American College of Medical Genetics for genomic copy number assessment by microarray analysis, and to determine the reproducibility and concordance among laboratory results from this test. Surveys were designed through the Cytogenetic Resource Committee of the two colleges to assess the ability of testing laboratories to process DNA samples provided and interpret results. Supplemental questions were asked with each Survey to determine laboratory practice trends. Twelve DNA specimens, representing 2 pilot and 10 Survey challenges, were distributed to as many as 74 different laboratories, yielding 493 individual responses. The mean consensus for matching result interpretations was 95.7%. Responses to supplemental questions indicate that the number of laboratories offering this testing is increasing, methods for analysis and evaluation are becoming standardized, and array platforms used are increasing in probe density. The College of American Pathologists/American College of Medical Genetics proficiency testing program for copy number assessment by cytogenomic microarray is a successful and efficient mechanism for assessing interlaboratory reproducibility. This will provide laboratories the opportunity to evaluate their performance and assure overall accuracy of patient results. The high level of concordance in laboratory responses across all testing platforms by multiple facilities highlights the robustness of this technology.

  18. Does Pharmacogenomic Testing Improve Clinical Outcomes for Major Depressive Disorder? A Systematic Review of Clinical Trials and Cost-Effectiveness Studies.

    PubMed

    Rosenblat, Joshua D; Lee, Yena; McIntyre, Roger S

    2017-06-01

    Pharmacogenomic testing has become scalable and available to the general public. Pharmacogenomics has shown promise for predicting antidepressant response and tolerability in the treatment of major depressive disorder (MDD). In theory, pharmacogenomics can improve clinical outcomes by guiding antidepressant selection and dosing. The current systematic review examines the extant literature to determine the impact of pharmacogenomic testing on clinical outcomes in MDD and assesses its cost-effectiveness. The MEDLINE/PubMed and Google Scholar databases were systematically searched for relevant articles published prior to October 2015. Search terms included various combinations of the following: major depressive disorder (MDD), depression, mental illness, mood disorder, antidepressant, response, remission, outcome, pharmacogenetic, pharmacogenomics, pharmacodynamics, pharmacokinetic, genetic testing, genome wide association study (GWAS), CYP450, personalized medicine, cost-effectiveness, and pharmacoeconomics. Of the 66 records identified from the initial search, relevant clinical studies, written in English, assessing the cost-effectiveness and/or efficacy of pharmacogenomic testing for MDD were included. Each publication was critically examined for relevant data. Two nonrandomized, open-label, 8-week, prospective studies reported overall greater improvement in depressive symptom severity in the group of MDD subjects receiving psychiatric care guided by results of combinatorial pharmacogenomic testing (GeneSight) when compared to the unguided group. One industry-sponsored, randomized, double-blind, 10-week prospective study reported a trend for improved outcomes for the GeneSight-guided group; however, the trend did not reach statistical significance. Another industry-sponsored, randomized, double-blind, 12-week prospective study reported a 2.5-fold increase in remission rates in the CNSDose-guided group (P < .0001). One naturalistic, unblinded, industry-sponsored study showed clinical improvement when pharmacogenomics testing guided prescribing; however, this study lacked a control group. A single cost-effectiveness study concluded that single gene testing was not cost-effective. Conversely, a separate study reported that combinatorial pharmacogenomic testing is cost-effective. A limited number of studies have shown promise for the clinical utility of pharmacogenomic testing; however, cost-effectiveness of pharmacogenomics, as well as demonstration of improved health outcomes, is not yet supported with replicated evidence. © Copyright 2017 Physicians Postgraduate Press, Inc.

  19. 40 CFR 790.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... substance or mixture is able to represent or substitute for another in a test or series of tests, and that... submitted to EPA and ends after an amount of time equal to that which had been required to develop data or after five years, whichever is later. Sponsor means the person or persons who design, direct and finance...

  20. 40 CFR 790.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... represent or substitute for another in a test or series of tests, and that the data from one substance can... and ends after an amount of time equal to that which had been required to develop data or after five years, whichever is later. Sponsor means the person or persons who design, direct and finance the...

Top