Denniff, Philip; Spooner, Neil
2010-11-01
Before shipping and storage, dried blood spot (DBS) samples must be dried in order to protect the integrity of the spots. In this article, we examine the time required to dry blood spot samples and the effects of different environmental conditions on their integrity. Under ambient laboratory conditions, DBS samples on Whatman 903(®), FTA(®) and FTA(®) Elute substrates are dry within 90 min of spotting. An additional 5% of moisture is lost during subsequent storage with desiccant. When exposed to elevated conditions of temperature and relative humidity, the DBS samples absorb moisture. DBS samples on FTA lose this moisture on being returned to ambient conditions. DBS samples on 903 show no visible signs of deterioration when stored at elevated conditions. However, these conditions cause the DBS to diffuse through the FTA Elute substrate. Blood spots are dry within 90 min of spotting. However, the substrates examined behave differently when exposed to conditions of high relative humidity and temperature, in some cases resulting in the integrity of the substrate and DBS sample being compromised. It is recommended that these factors be investigated as part of method development and validation.
Effect of ambient humidity on the rate at which blood spots dry and the size of the spot produced.
Denniff, Philip; Woodford, Lynsey; Spooner, Neil
2013-08-01
For shipping and storage, dried blood spot (DBS) samples must be sufficiently dry to protect the integrity of the sample. When the blood is spotted the humidity has the potential to affect the size of the spot created and the speed at which it dries. The area of DBS produced on three types of substrates were not affected by the humidity under which they were generated. DBS samples reached a steady moisture content 150 min after spotting and 90 min for humidities less than 60% relative humidity. All packaging materials examined provided some degree of protection from external extreme conditions. However, none of the packaging examined provided a total moisture barrier to extreme environmental conditions. Humidity was shown not to affect the spot area and DBS samples were ready for shipping and storage 2 h after spotting. The packing solutions examined all provided good protection from external high humidity conditions.
Barcenas, Mariana; Suhr, Teryn R; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H
2014-06-10
Treatments are being developed for metachromatic leukodystrophy (MLD), suggesting the need for eventual newborn screening. Previous studies have shown that sulfatide molecular species are increased in the urine of MLD patients compared to samples from non-MLD individuals, but there is no data using dried blood spots (DBS), the most common sample available for newborn screening laboratories. We used ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) to quantify sulfatides in DBS and dried urine spots from 14 MLD patients and 50 non-MLD individuals. Several sulfatide molecular species were increased in dried urine samples from all MLD samples compared to non-MLD samples. Sulfatides, especially low molecular species, were increased in DBS from MLD patients, but the sulfatide levels were relatively low. There was good separation in sulfatide levels between MLD and non-MLD samples when dried urine spots were used, but not with DBS, because DBS from non-MLD individuals have measurable levels of sulfatides. Sulfatide accumulation studies in urine, but not in DBS, emerges as the method of choice if newborn screening is to be proposed for MLD. Copyright © 2013 Elsevier B.V. All rights reserved.
Mahajan, Supriya; Choudhary, Manish Chandra; Kumar, Guresh; Gupta, Ekta
2018-06-01
Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log 10 IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log 10 IU/ml was comparable to DBS (3.93; range 0-7.24) log 10 IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r 2 = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.
Fan, Leimin; Lee, Jacob; Hall, Jeffrey; Tolentino, Edward J; Wu, Huaiqin; El-Shourbagy, Tawakol
2011-06-01
This article describes validation work for analysis of an Abbott investigational drug (Compound A) in monkey whole blood with dried blood spots (DBS). The impact of DBS spotting volume on analyte concentration was investigated. The quantitation range was between 30.5 and 10,200 ng/ml. Accuracy and precision of quality controls, linearity of calibration curves, matrix effect, selectivity, dilution, recovery and multiple stabilities were evaluated in the validation, and all demonstrated acceptable results. Incurred sample reanalysis was performed with 57 out of 58 samples having a percentage difference (versus the mean value) less than 20%. A linear relationship between the spotting volume and the spot area was drawn. The influence of spotting volume on concentration was discussed. All validation results met good laboratory practice acceptance requirements. Radial spreading of blood on DBS cards can be a factor in DBS concentrations at smaller spotting volumes.
Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS
NASA Astrophysics Data System (ADS)
Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.
2013-09-01
Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.
Stability of Phosphatidylethanol in Dry Blood Spot Cards.
Bakhireva, Ludmila N; Shrestha, Shikhar; Gutierrez, Hilda L; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee
2016-05-01
The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, -80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at -80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature-time interaction on PEth degradation over the first 9 months. The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. © The Author 2015. Medical Council on Alcohol and Oxford University Press. All rights reserved.
Stability of Phosphatidylethanol in Dry Blood Spot Cards
Bakhireva, Ludmila N.; Shrestha, Shikhar; Gutierrez, Hilda L.; Berry, Mike; Schmitt, Cheryl; Sarangarm, Dusadee
2016-01-01
Background The analysis of phosphatidylethanol, a promising direct ethanol metabolite, in dry blood spots (PEth-DBS) is advantageous due to ease of storage, transportation and minimal invasiveness of capillary blood collection. One potential application of PEth-DBS is to confirm prenatal alcohol exposure in newborns suspected of FASD; however, stability of PEth-DBS is largely unknown. Methods Phlebotomized samples from 31 adults with a history of alcoholism, admitted to the University of New Mexico Emergency Department, were analyzed for blood alcohol content and pipetted onto DBS cards (13 spots per patient). The first spot was analyzed within 2 weeks of collection for a baseline PEth; the remaining 12 spots were allocated into three temperature conditions (room temperature, 4°C, −80°C) for the repeated measures analysis. In addition, 5 newborn DBS samples with a baseline PEth>LOD were obtained from a prospective cohort at UNM and re-analyzed at 4 months after storage at −80°C. A mixed linear model was fitted to examine the effects of temperature, time and temperature–time interaction on PEth degradation over the first 9 months. Results The baseline PEth levels were 592.8 ± 86.7 ng/ml and 18.3 ± 4.8 ng/ml in adult and newborn samples, respectively. All DBS samples remained positive in successive samples in all temperature conditions. Results of mixed linear model demonstrated a significant effect of temperature (P < 0.001) on PEth degradation over 9 months. Conclusions PEth-DBS appears to be relatively stable, especially when stored at lower temperatures. These initial results are encouraging and highlight the PEth-DBS potential in retrospective assessment of alcohol exposure. PMID:26519350
van der Elst, Kim C. M.; Span, Lambert F. R.; van Hateren, Kai; Vermeulen, Karin M.; van der Werf, Tjip S.; Greijdanus, Ben; Kosterink, Jos G. W.; Uges, Donald R. A.
2013-01-01
Invasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P = 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling. PMID:23896473
Smit, Pieter W.; Sollis, Kimberly A.; Fiscus, Susan; Ford, Nathan; Vitoria, Marco; Essajee, Shaffiq; Barnett, David; Cheng, Ben; Crowe, Suzanne M.; Denny, Thomas; Landay, Alan; Stevens, Wendy; Habiyambere, Vincent; Perriens, Joseph H.; Peeling, Rosanna W.
2014-01-01
Background Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID. Methods and Findings Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52–100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78–100% compared to plasma at VL below 1000 copies/ml, but this increased to 100% at a threshold of 5000 copies/ml. Unlike a plasma VL test which measures only cell free HIV RNA, a DBS VL also measures proviral DNA as well as cell-associated RNA, potentially leading to false positive results when using DBS. The systematic review showed that specificity was close to 100% at DBS VL above 5000 copies/ml, and this threshold would be the most reliable for predicting true virologic failure using DBS. For early infant diagnosis, DBS has a sensitivity of 100% compared to fresh whole blood or plasma in all studies. Conclusions Although limited data are available for EID, DBS offer a highly sensitive and specific sampling strategy to make viral load monitoring and early infant diagnosis more accessible in remote settings. A standardized approach for sampling, storing, and processing DBS samples would be essential to allow successful implementation. Trial Registration PROSPERO Registration #: CRD42013003621. PMID:24603442
Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V
2013-04-01
Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) use costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet detection appropriate for resource-limited settings. One hundred microliters of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase high-performance liquid chromatography column. EFV is separated isocratically using a potassium phosphate and acetonitrile mobile phase. Ultraviolet detection is at 245 nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Mean recovery of drug from DBS is 91.5%. The method is linear over the validated concentration range of 0.3125-20.0 μg/mL. A good correlation (Spearman r = 0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed C DBS/C plasma ratio was 0.68. A good correlation (Spearman r = 0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource-limited settings, particularly when high sensitivity is not essential.
Quantification of multiple elements in dried blood spot samples.
Pedersen, Lise; Andersen-Ranberg, Karen; Hollergaard, Mads; Nybo, Mads
2017-08-01
Dried blood spots (DBS) is a unique matrix that offers advantages compared to conventional blood collection making it increasingly popular in large population studies. We here describe development and validation of a method to determine multiple elements in DBS. Elements were extracted from punches and analyzed using inductively coupled plasma-mass spectrometry (ICP-MS). The method was evaluated with quality controls with defined element concentration and blood spiked with elements to assess accuracy and imprecision. DBS element concentrations were compared with concentrations in venous blood. Samples with different hematocrit were spotted onto filter paper to assess hematocrit effect. The established method was precise and accurate for measurement of most elements in DBS. There was a significant but relatively weak correlation between measurement of the elements Mg, K, Fe, Cu, Zn, As and Se in DBS and venous whole blood. Hematocrit influenced the DBS element measurement, especially for K, Fe and Zn. Trace elements can be measured with high accuracy and low imprecision in DBS, but contribution of signal from the filter paper influences measurement of some elements present at low concentrations. Simultaneous measurement of K and Fe in DBS extracts may be used to estimate sample hematocrit. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien
2015-02-17
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Zheng, Naiyu; Yuan, Long; Ji, Qin C; Mangus, Heidi; Song, Yan; Frost, Charles; Zeng, Jianing; Aubry, Anne-Françoise; Arnold, Mark E
2015-04-15
Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards. Copyright © 2015 Elsevier B.V. All rights reserved.
Sadones, Nele; Archer, John R H; Ingels, Ann-Sofie M E; Dargan, Paul I; Wood, David M; Wood, Michelle; Neels, Hugo; Lambert, Willy E; Stove, Christophe P
2015-04-01
Gamma-hydroxybutyric acid (GHB) is a well-known illicit club and date-rape drug. Dried blood spot (DBS) sampling is a promising alternative for classical venous sampling in cases of (suspected) GHB intoxication since it allows rapid sampling, which is of interest for the extensively metabolized GHB. However, there is limited data if -and how- capillary DBS concentrations correlate with venous concentrations. We conducted a comparative study in 50 patients with suspected GHB intoxication, to determine and to correlate GHB concentrations in venous DBS (vDBS) and capillary DBS (cDBS). This is the first study that evaluates in a large cohort the correlation between capillary and venous concentrations of an illicit drug in real-life samples. Of the 50 paired samples, 7 were excluded: the vDBS concentration was below the LLOQ of 2 µg/mL in 3 cases and 4 samples were excluded after visual inspection of the DBS. Bland-Altman analysis revealed a mean % difference of -2.8% between cDBS and vDBS concentrations, with the zero value included in the 95% confidence interval of the mean difference in GHB concentration. A paired sample t-test confirmed this observation (p = 0.17). Also the requirement for incurred sample reproducibility was fulfilled: for more than two-thirds of the samples the concentrations obtained in cDBS and those in vDBS were within 20% of their mean. Since equivalent concentrations were observed in cDBS and vDBS, blood obtained by fingerprick can be considered a valid alternative for venous blood for GHB determination. Copyright © 2015 John Wiley & Sons, Ltd.
Sadones, Nele; Van Bever, Elien; Archer, John R H; Wood, David M; Dargan, Paul I; Van Bortel, Luc; Lambert, Willy E; Stove, Christophe P
2016-09-23
Dried blood spot (DBS) sampling and analysis is increasingly being applied in bioanalysis. Although the use of DBS has many advantages, it is also associated with some challenges. E.g. given the limited amount of available material, highly sensitive detection techniques are often required to attain sufficient sensitivity. In gas chromatography coupled to mass spectrometry (GC-MS), derivatization can be helpful to achieve adequate sensitivity. Because this additional sample preparation step is considered as time-consuming, we introduce a new derivatization procedure, i.e. "microwave-assisted on-spot derivatization", to minimize sample preparation of DBS. In this approach the derivatization reagents are directly applied onto the DBS and derivatization takes place in a microwave instead of via conventional heating. In this manuscript we evaluated the applicability of this new concept of derivatization for the determination of two polar low molecular weight molecules, gamma-hydroxybutyric acid (GHB) and gabapentin, in DBS using a standard GC-MS configuration. The method was successfully validated for both compounds, with imprecision and bias values within acceptance criteria (<20% at LLOQ, <15% at 3 other QC levels). Calibration lines were linear over the 10-100μg/mL and 1-30μg/mL range for GHB and gabapentin, respectively. Stability studies revealed no significant decrease of gabapentin and GHB in DBS upon storage at room temperature for at least 84 days. Furthermore, DBS-specific parameters, including hematocrit and volume spotted, were evaluated. As demonstrated by the analysis of GHB and gabapentin positive samples, "microwave-assisted on-spot derivatization" proved to be reliable, fast and applicable in routine toxicology. Moreover, other polar low molecular weight compounds of interest in clinical and/or forensic toxicology, including vigabatrin, beta-hydroxybutyric acid, propylene glycol, diethylene glycol, 1,4-butanediol and 1,2-butanediol, can also be detected using this method. Copyright © 2016 Elsevier B.V. All rights reserved.
Jones, Trevor G.; Warber, Kimbrough D.; Roberts, Billy D.
2010-01-01
Background Hemoglobin A1c (HbA1c) has been endorsed as a tool for the diagnosis of diabetes. This test requires instrumentation that may not be available in underdeveloped areas. Dried blood spot (DBS) samples collected by finger stick procedures offer a mechanism to transport samples to laboratories that do measure HbA1c. Methods Whole blood (ethylenediaminetetraacetic acid) was applied to Ahlstrom 226 filter paper. These DBS samples were compared to whole blood samples using the Roche Tina-quant® II immunoturbidometric assay. Hemoglobin A1c stability on DBS was assessed at three temperatures—4, 25, and 40°C—for up to 9 days. A 44-day study was also done for DBS at 20–25°C. Results The Tina-quant® II DBS method showed excellent agreement with whole blood HbA1c results (r2 = 0.99) with a slight positive mean bias of 0.08 ± 0.04% HbA1c (95% confidence interval). The variation in HbA1c on DBS samples subjected to different temperatures and times did not exceed 5.6%. Conclusions Dried blood spot samples represent an alternative to whole blood for HbA1c by measurement when transporting whole blood is not feasible. PMID:20307383
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
Lin, Yong-Qing; Zhang, Yilu; Li, Connie; Li, Louis; Zhang, Kelley; Li, Shawn
2012-01-01
To evaluate the dried blood spot (DBS) technique in ELISA quantification of larger biomolecular drugs, an anti-CD20 monoclonal antibody drug was used as an example. A method for the quantification of the anti-CD20 drug in human DBS was developed and validated. The drug standard and quality control samples prepared in fresh human blood were spotted on DBS cards and then extracted. A luminescent ELISA was used for quantification of the drug from DBS samples. The assay range of the anti-CD20 drug standards in DBS was 100-2500ng/mL. The intra-assay precision (%CV) ranged from 0.4% to 10.1%, and the accuracy (%Recovery) ranged from 77.9% to 113.9%. The inter assay precision (%CV) ranged from 5.9% to 17.4%, and the accuracy ranged from 81.5% to 110.5%. The DBS samples diluted 500 and 50-fold yielded recovery of 88.7% and 90.7%, respectively. The preparation of DBS in higher and lower hematocrit (53% and 35%) conditions did not affect the recovery of the drug. Furthermore, the storage stability of the anti-CD20 drug on DBS cards was tested at various conditions. It was found that the anti-CD20 drug was stable for one week in DBS stored at room temperature. However, it was determined that the stability was compro]mised in DBS stored at high humidity, high temperature (55°C), and exposed to direct daylight for a week, as well as for samples stored at room temperature and high humidity conditions for a month. Stability did not change significantly in samples that underwent 3 freeze/thaw cycles. Our results demonstrated a successful use of DBS technique in ELISA quantification of an anti-CD20 monoclonal antibody drug in human blood. The stability data provides information regarding sample storage and shipping for future clinical studies. It is, therefore, concluded that the DBS technique is applicable in the quantification of other large biomolecule drugs or biomarkers. Copyright © 2011 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kyle, Jennifer E.; Casey, Cameron P.; Stratton, Kelly G.
The use of dried blood spots (DBS) has many advantages over traditional plasma and serum samples such as smaller blood volume required, storage at room temperature, and ability for sampling in remote locations. However, understanding the robustness of different analytes in DBS samples is essential, especially in older samples collected for longitudinal studies. Here we analyzed DBS samples collected in 2000-2001 and stored at room temperature and compared them to matched serum samples stored at -80°C to determine if they could be effectively used as specific time points in a longitudinal study following metabolic disease. Four hundred small molecules weremore » identified in both the serum and DBS samples using gas chromatograph-mass spectrometry (GC-MS), liquid chromatography-MS (LC-MS) and LC-ion mobility spectrometry-MS (LC-IMS-MS). The identified polar metabolites overlapped well between the sample types, though only one statistically significant polar metabolite in a case-control study was conserved, indicating degradation occurs in the DBS samples affecting quantitation. Differences in the lipid identifications indicated that some oxidation occurs in the DBS samples. However, thirty-six statistically significant lipids correlated in both sample types indicating that lipid quantitation was more stable across the sample types.« less
Rosypal, Alexa C; Pick, Leanne D; Hernandez, Jaime O Esquivel; Lindsay, David S
2014-09-15
Collection of blood samples from veterinary and wildlife patients is often challenging because the samples have to be collected on farm or in the wild under various environmental conditions. This poses many technical problems associated with venipuncture materials, their safe use and disposal, transportation and processing of collected samples. Dried blood spot (DBS) sample collection techniques offer a simple and practical alternative to traditional blood collection methods to obtain blood samples from animals for parasite antibody evaluation. The DBS collection devices are compact, simple to use, and are particularly useful for large number of samples. Additionally, DBS samples take up less space and they are easier to transport than traditional venipuncture-collected blood samples. Visceral leishmaniasis (VL) is a potentially fatal parasitic disease of dogs and humans and it is frequently diagnosed by antibody tests. Immunochromatographic tests (ICT) for antibodies to Leishmania infantum are commercially available for dogs and they produce qualitative results in minutes. Measurement of canine antibodies to L. infantum with the ICT using traditional venipuncture has been validated previously, but the use of DBS samples has not been evaluated using this method. The purpose of the present study was to determine the ability of DBS samples to detect antibodies to L. infantum in dogs using a commercial ICT assay. One hundred plasma samples from dogs experimentally infected with the LIVT-1 strain of L. infantum were collected by venipuncture and frozen. Individual samples were thawed, and then 80 μl plasma (2 drops) was aliquotted onto the 8-spoked disk pad on individual DBS sample collection devices (HemaSpot™, Spot-On Sciences, Austin, TX), dried, and stored in the dark at room temperature. After one month and six months, respectively, 2 spokes of the 8 spokes of the disk pad of each DBS sample were removed and eluted in 200 μl PBS. The eluate was used to test for antibodies in the ICT and compared to ICT results using thawed plasma (same initial source). Sensitivity and specificity of the ICT using DBS were determined by using ICT results from traditional blood collection samples for comparison. After 1 month, DBS samples showed 100% sensitivity and specificity when compared to ICT results on thawed plasma samples collected by traditional venipuncture. After six months storage at room temperature, DBS samples demonstrated 79% sensitivity and 100% specificity compared to traditional blood collection. Results from this study indicate that dried blood spot collection may be a useful tool for screening dogs for antibodies to L. infantum with the ICT assay. Copyright © 2014 Elsevier B.V. All rights reserved.
Jensen, Berit P; Saraf, Rajneeta; Ma, Jing; Berry, Sarah; Grant, Cameron C; Camargo, Carlos A; Sies, Christiaan W
2018-06-01
Demand for measurement of 25-hydroxyvitamin D (25OHD) is growing and dried blood spot (DBS) sampling is attractive as samples are easier to collect, transport and store. A 2D LC-MS/MS assay without derivatization was developed. DBS punches (3.2 mm) were ultrasonicated with d 6 -25OHD 3 in 70% methanol followed by hexane extraction, dry-down and reconstitution. The assay was validated and applied to two studies comparing whole blood adult DBS with serum samples (n = 40) and neonatal whole blood DBS with cord serum samples (n = 80). The assay was validated in whole blood DBS over the range 13-106 nmol/L 25OHD 3 and 11-91 nmol/L 25OHD 2 with a limit of detection of 3 nmol/L. Intra- and inter-day imprecision was <13% CV and bias <12%. The assay had high recovery and minimal matrix effects. Triplicate DBS study samples had a mean CV of ≤13% for 25OHD 3. No 25OHD 2 was detected. DBS calculated serum 25OHD 3 concentrations correlated strongly with serum concentrations in the adult DBS/serum study (r = 0.94) and moderately in the neonatal DBS/cord serum study (r = 0.69). Direct quantitation of 25OHD in DBS by 2D LC-MS/MS without derivatization was found to be an alternative to serum quantitation applicable to clinical research studies on adult DBS samples. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Raju, Kanumuri Siva Rama; Taneja, Isha; Rashid, Mamunur; Sonkar, Ashish Kumar; Wahajuddin, Muhammad; Singh, Sheelendra Pratap
2016-03-01
A simple, sensitive and high throughput LC-MS/MS method was developed and validated for quantification of fipronil, fipronil sulfone and fipronil desulfinyl in rat and human dried blood spots (DBS). DBS samples were prepared by spiking 10 μl blood on DMPK-C cards followed by drying at room temperature. The whole blood spots were then punched from the card and extracted using acetonitrile. The total chromatographic run time of the method was only 2 min. The lower limit of quantification of the method was 0.1 ng/ml for all the analytes. The method was successfully applied to determine fipronil desulfinyl in DBS samples obtained from its toxicokinetic study in rats following intravenous dose (1 mg/kg). In conclusion, the proposed DBS methodology has significant potential in toxicokinetics and biomonitoring studies of environmental toxicants. This microvolume DBS technique will be an ideal tool for biomonitoring studies, particularly in paediatric population. Small volume requirements, minimally invasive blood sampling method, easier storage and shipping procedure make DBS a suitable technique for such studies. Further, DBS technique contributes towards the principles of 3Rs resulting in significant reduction in the number of rodents used and refinement in sample collection for toxicokinetic studies.
Dried Blood Spot RNA Transcriptomes Correlate with Transcriptomes Derived from Whole Blood RNA.
Reust, Mary J; Lee, Myung Hee; Xiang, Jenny; Zhang, Wei; Xu, Dong; Batson, Tatiana; Zhang, Tuo; Downs, Jennifer A; Dupnik, Kathryn M
2018-05-01
Obtaining RNA from clinical samples collected in resource-limited settings can be costly and challenging. The goals of this study were to 1) optimize messenger RNA extraction from dried blood spots (DBS) and 2) determine how transcriptomes generated from DBS RNA compared with RNA isolated from blood collected in Tempus tubes. We studied paired samples collected from eight adults in rural Tanzania. Venous blood was collected on Whatman 903 Protein Saver cards and in tubes with RNA preservation solution. Our optimal DBS RNA extraction used 8 × 3-mm DBS punches as the starting material, bead beater disruption at maximum speed for 60 seconds, extraction with Illustra RNAspin Mini RNA Isolation kit, and purification with Zymo RNA Concentrator kit. Spearman correlations of normalized gene counts in DBS versus whole blood ranged from 0.887 to 0.941. Bland-Altman plots did not show a trend toward over- or under-counting at any gene size. We report a method to obtain sufficient RNA from DBS to generate a transcriptome. The DBS transcriptome gene counts correlated well with whole blood transcriptome gene counts. Dried blood spots for transcriptome studies could be an option when field conditions preclude appropriate collection, storage, or transport of whole blood for RNA studies.
Rapid DNA extraction from dried blood spots on filter paper: potential applications in biobanking.
Choi, Eun-Hye; Lee, Sang Kwang; Ihm, Chunhwa; Sohn, Young-Hak
2014-12-01
Dried blood spot (DBS) technology is a microsampling alternative to traditional plasma or serum sampling for pharmaco- or toxicokinetic evaluation. DBS technology has been applied to diagnostic screening in drug discovery, nonclinical, and clinical settings. We have developed an improved elution protocol involving boiling of blood spots dried on Whatman filter paper. The purpose of this study was to compare the quality, purity, and quantity of DNA isolated from frozen blood samples and DBSs. We optimized a method for extraction and estimation of DNA from blood spots dried on filter paper (3-mm FTA card). A single DBS containing 40 μL blood was used. DNA was efficiently extracted in phosphate-buffered saline (PBS) or Tris-EDTA (TE) buffer by incubation at 37°C overnight. DNA was stable in DBSs that were stored at room temperature or frozen. The housekeeping genes GAPDH and beta-actin were used as positive standards for polymerase chain reaction (PCR) validation of general diagnostic screening. Our simple and convenient DBS storage and extraction methods are suitable for diagnostic screening by using very small volumes of blood collected on filter paper, and can be used in biobanks for blood sample storage.
Dried blood spot analysis for therapeutic drug monitoring of pazopanib.
de Wit, Djoeke; den Hartigh, Jan; Gelderblom, Hans; Qian, Yanwen; den Hollander, Margret; Verheul, Henk; Guchelaar, Henk-Jan; van Erp, Nielka P
2015-12-01
Dried blood spot (DBS) sampling is potentially a more patient-friendly and flexible alternative to venous sampling of pazopanib. This study determined the agreement between pazopanib DBS and plasma concentrations to facilitate implementation of pazopanib DBS sampling into clinical practice. Paired DBS and plasma samples were collected in 12 patients. Pazopanib plasma concentrations were calculated from DBS concentrations using the formula: plasma concentration = DBSconcentration /(1 - hematocrit). Passing-Bablok and Bland-Altman analyses were used to determine the agreement between calculated and measured plasma concentrations. We predefined a clinical acceptance limit of 25% for the Bland-Altman analysis. Passing-Bablok analysis showed a small constant (intercept estimate, -8.53 [95%CI, -12.22 to -4.41]) and slightly proportional (slope estimate, 1.15 [95%CI, 1.04-1.24]) bias between calculated and measured concentrations. This bias was clinically nonrelevant, as shown by Bland-Altman analysis; the mean ratio of calculated to measured concentrations was 0.94 (95%CI, 0.65-1.23). The clinical acceptance limits were well within these 95% limits of agreement. More specifically, 92.6% of the data points were within the predefined acceptance limits. Pazopanib plasma concentrations can be accurately calculated from DBS concentrations. Although validation of DBS cards prepared by patients themselves is required, these results show that DBS sampling can be used to monitor pazopanib therapy in clinical practice. © 2015, The American College of Clinical Pharmacology.
Struniawski, R; Szpechcinski, A; Poplawska, B; Skronski, M; Chorostowska-Wynimko, J
2013-01-01
The dried blood spot (DBS) specimens have been successfully employed for the large-scale diagnostics of α1-antitrypsin (AAT) deficiency as an easy to collect and transport alternative to plasma/serum. In the present study we propose a fast, efficient, and cost effective protocol of DNA extraction from dried blood spot (DBS) samples that provides sufficient quantity and quality of DNA and effectively eliminates any natural PCR inhibitors, allowing for successful AAT genotyping by real-time PCR and direct sequencing. DNA extracted from 84 DBS samples from chronic obstructive pulmonary disease patients was genotyped for AAT deficiency variants by real-time PCR. The results of DBS AAT genotyping were validated by serum IEF phenotyping and AAT concentration measurement. The proposed protocol allowed successful DNA extraction from all analyzed DBS samples. Both quantity and quality of DNA were sufficient for further real-time PCR and, if necessary, for genetic sequence analysis. A 100% concordance between AAT DBS genotypes and serum phenotypes in positive detection of two major deficiency S- and Z- alleles was achieved. Both assays, DBS AAT genotyping by real-time PCR and serum AAT phenotyping by IEF, positively identified PI*S and PI*Z allele in 8 out of the 84 (9.5%) and 16 out of 84 (19.0%) patients, respectively. In conclusion, the proposed protocol noticeably reduces the costs and the hand-on-time of DBS samples preparation providing genomic DNA of sufficient quantity and quality for further real-time PCR or genetic sequence analysis. Consequently, it is ideally suited for large-scale AAT deficiency screening programs and should be method of choice.
Hoffman, Justin T; Rossi, Steven S; Espina-Quinto, Rowena; Letendre, Scott; Capparelli, Edmund V
2013-01-01
Background Previously published methods for determination of efavirenz (EFV) in human dried blood spots (DBS) employ costly and complex liquid chromatography/mass spectrometry. We describe the validation and evaluation of a simple and inexpensive high-performance liquid chromatography (HPLC) method for EFV quantification in human DBS and dried plasma spots (DPS), using ultraviolet (UV) detection appropriate for resource-limited settings. Methods 100μl of heparinized whole blood or plasma were spotted onto blood collection cards, dried, punched, and eluted. Eluates are injected onto a C-18 reversed phase HPLC column. EFV is separated isocratically using a potassium phosphate and ACN mobile phase. UV detection is at 245nm. Quantitation is by use of external calibration standards. Following validation, the method was evaluated using whole blood and plasma from HIV-positive patients undergoing EFV therapy. Results Mean recovery of drug from dried blood spots is 91.5%. The method is linear over the validated concentration range of 0.3125 – 20.0μg/mL. A good correlation (Spearman r=0.96) between paired plasma and DBS EFV concentrations from the clinical samples was observed, and hematocrit level was not found to be a significant determinant of the EFV DBS level. The mean observed CDBS/Cplasma ratio was 0.68. A good correlation (Spearman r=0.96) between paired plasma and DPS EFV concentrations from the clinical samples was observed. The mean percent deviation of DPS samples from plasma samples is 1.68%. Conclusions Dried whole blood spot or dried plasma spot sampling is well suited for monitoring EFV therapy in resource limited settings, particularly when high sensitivity is not essential. PMID:23503446
Performance and Storage Integrity of Dried Blood Spots for PCB, BFR and Pesticide Measurements
Batterman, Stuart; Chernyak, Sergei
2014-01-01
Dried blood spots (DBS) can provide accurate and valuable estimates of exposure to environmental toxicants, and the use of information derived from archived newborn DBS information has enormous potential to open up new research on the impacts of early chemical exposure on disease. Broad application of DBS for the purpose of quantitative exposure estimation requires robust and validated methods. This study investigates the suitability of DBS analyses for population studies of exposure to three chemical groups: polychlorinated biphenyls (PCBs), brominated flame retardants (BFRs), and chlorinated pesticides. It examines background (matrix) contamination, recovery and extraction variability, sensitivity, and storage stability. DBS samples prepared using 50 μL of adult blood were analyzed by GC/MS, and method performance was confirmed by using certified materials and paired DBS-blood samples from six volunteers. Several of the target compounds and their degradation products have not been previously measured in DBS. All target compounds were detected in DBS samples collected from the volunteers. Sample DBS cards showed background contamination of several compounds. When stored at room temperature, target compounds, excluding PBDEs, were stable for up to one month. When refrigerated or frozen, stability was acceptable for all compounds up to one year, and multiyear storage appears acceptable at colder (e.g., −80 °C) temperatures. Multicompartment models may be used to estimate or correct for storage losses. Considering concentrations of contaminants for adults and children reported in the literature, and experimental values of detection limits and background contamination, DBS samples are suitable for quantifying exposures to many PCBs, BFRs and persistent pesticides. PMID:25058892
Evaluation of HBsAg and anti-HBc assays in saliva and dried blood spot samples according HIV status.
Flores, Geane Lopes; Cruz, Helena Medina; Potsch, Denise Vigo; May, Silvia Beatriz; Brandão-Mello, Carlos Eduardo; Pires, Marcia Maria Amendola; Pilotto, Jose Henrique; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo
2017-09-01
Influence of HIV status in HBV markers detection in saliva and dried blood spots (DBS) was not well established. This study aims to evaluate the performance of optimized commercial immunoassay for identifying HBsAg and anti-HBc in saliva and DBS according HIV status. A sum of 535 individuals grouped as HIV + , HBV + , HIV/HBV + and HIV/HBV- were recruited where 347 and 188 were included for HBsAg and anti-HBc evaluation, respectively. Serum, DBS collected in Whatman 903 paper and saliva obtained using salivette device were analyzed using EIA. Increased sample volume and ROC curve analysis for cut off determination were used for DBS and saliva testing. HBsAg detection in saliva and DBS exhibited sensitivities of 80.9% and 85.6% and specificities of 86.8% and 96.3%. Sensitivity of anti-HBc in saliva and DBS were 82.4% and 76.9% and specificities in saliva and DBS were 96.9% and 91.7%. Low sensitivities were observed for HBsAg (62%) and anti-HBc (47%) detection in saliva of HIV/HBV+ individuals. OD values were also lower for HBsAg detection in DBS and saliva of HIV/HBV+ individuals compared to their serum samples. Statistical significance was found for sensitivities in HBsAg detection between saliva and DBS demonstrating high sensitivity for DBS specimens. In conclusion, HIV status or antiretroviral treatment appears to interfere in the performance of HBsAg and anti-HBc detection in DBS and saliva samples using the adapted commercial EIA. Copyright © 2017 Elsevier B.V. All rights reserved.
Use of dried blood spots for the determination of serum concentrations of tamoxifen and endoxifen.
Jager, N G L; Rosing, H; Schellens, J H M; Beijnen, J H; Linn, S C
2014-07-01
The anti-estrogenic effect of tamoxifen is suggested to be mainly attributable to its metabolite (Z)-endoxifen, and a minimum therapeutic threshold for (Z)-endoxifen in serum has been proposed. The objective of this research was to establish the relationship between dried blood spot (DBS) and serum concentrations of tamoxifen and (Z)-endoxifen to allow the use of DBS sampling, a simple and patient-friendly alternative to venous sampling, in clinical practice. Paired DBS and serum samples were obtained from 50 patients using tamoxifen and analyzed using HPLC-MS/MS. Serum concentrations were calculated from DBS concentrations using the formula calculated serum concentration = DBS concentration/([1-haematocrit (Hct)] + blood cell-to-serum ratio × Hct). The blood cell-to-serum ratio was determined ex vivo by incubating a batch of whole blood spiked with both analytes. The average Hct for female adults was imputed as a fixed value. Calculated and analyzed serum concentrations were compared using weighted Deming regression. Weighted Deming regression analysis comparing 44 matching pairs of DBS and serum samples showed a proportional bias for both analytes. Serum concentrations were calculated using [Tamoxifen] serum, calculated = [Tamoxifen] DBS /0.779 and [(Z)-Endoxifen] serum, calculated = [(Z)-Endoxifen] DBS /0.663. Calculated serum concentrations were within 20 % of analyzed serum concentrations in 84 and 100 % of patient samples for tamoxifen and (Z)-endoxifen, respectively. In conclusion, DBS concentrations of tamoxifen and (Z)-endoxifen were equal to serum concentrations after correction for Hct and blood cell-to-serum ratio. DBS sampling can be used in clinical practice.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-03-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 μL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal-often to a single collection per mouse-thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 μL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study.
Wickremsinhe, Enaksha R; Perkins, Everett J
2015-01-01
Traditional pharmacokinetic analysis in nonclinical studies is based on the concentration of a test compound in plasma and requires approximately 100 to 200 µL blood collected per time point. However, the total blood volume of mice limits the number of samples that can be collected from an individual animal—often to a single collection per mouse—thus necessitating dosing multiple mice to generate a pharmacokinetic profile in a sparse-sampling design. Compared with traditional methods, dried blood spot (DBS) analysis requires smaller volumes of blood (15 to 20 µL), thus supporting serial blood sampling and the generation of a complete pharmacokinetic profile from a single mouse. Here we compare plasma-derived data with DBS-derived data, explain how to adopt DBS sampling to support discovery mouse studies, and describe how to generate pharmacokinetic and pharmacodynamic data from a single mouse. Executing novel study designs that use DBS enhances the ability to identify and streamline better drug candidates during drug discovery. Implementing DBS sampling can reduce the number of mice needed in a drug discovery program. In addition, the simplicity of DBS sampling and the smaller numbers of mice needed translate to decreased study costs. Overall, DBS sampling is consistent with 3Rs principles by achieving reductions in the number of animals used, decreased restraint-associated stress, improved data quality, direct comparison of interanimal variability, and the generation of multiple endpoints from a single study. PMID:25836959
Comparison of cross-sectional HIV incidence assay results from dried blood spots and plasma.
Schlusser, Katherine E; Pilcher, Christopher; Kallas, Esper G; Santos, Breno R; Deeks, Steven G; Facente, Shelley; Keating, Sheila M; Busch, Michael P; Murphy, Gary; Welte, Alex; Quinn, Thomas; Eshleman, Susan H; Laeyendecker, Oliver
2017-01-01
Assays have been developed for cross-sectional HIV incidence estimation using plasma samples. Large scale surveillance programs are planned using dried blood spot (DBS) specimens for incidence assessment. However, limited information exists on the performance of HIV cross-sectional incidence assays using DBS. The assays evaluated were: Maxim HIV-1 Limiting Antigen Avidity EIA (LAg-Avidity), Sedia HIV-1 BED-Capture EIA (BED-CEIA), and CDC modified BioRad HIV-1/2 Plus O Avidity-based Assay (CDC-BioRad Avidity) using pre-determined cutoff values. 100 matched HIV-1 positive plasma and DBS samples, with known duration of infection, from the Consortium for the Evaluation and Performance of HIV Incidence Assays repository were tested. All assays were run in duplicate. To examine the degree of variability within and between results for each sample type, both categorical and continuous results were analyzed. Associations were assessed with Bland Altman, R2 values and Cohen's kappa coefficient (ĸ). Intra-assay variability using the same sample type was similar for all assays (R2 0.96 to 1.00). The R2 values comparing DBS and plasma results for LAg-Avidity, BED-CEIA, and CDC-BioRad Avidity were 0.96, 0.94, and 0.84, respectively. The concordance and ĸ values between DBS and plasma for all three assays were >87% and >0.64, respectively. The Bland-Altman analysis showed significant differences between plasma and DBS samples. For all three assays, a higher number of samples were classified as recent infections using DBS samples. DBS and plasma sample results were highly correlated. However, when compared to plasma, each assay performed somewhat differently in DBS at the lower and higher ends of the dynamic range. DBS samples were more likely to be classified as recently infected by all three assays, which may lead to overestimation of incidence in surveys using performance criteria derived for plasma samples.
Parsons, Teresa L.; Marzinke, Mark A.; Hoang, Thuy; Bliven-Sizemore, Erin; Weiner, Marc; Mac Kenzie, William R.; Dorman, Susan E.
2014-01-01
The quantification of antituberculosis drug concentrations in multinational trials currently requires the collection of modest blood volumes, centrifugation, aliquoting of plasma, freezing, and keeping samples frozen during shipping. We prospectively enrolled healthy individuals into the Tuberculosis Trials Consortium Study 29B, a phase I dose escalation study of rifapentine, a rifamycin under evaluation in tuberculosis treatment trials. We developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantifying rifapentine in whole blood on dried blood spots (DBS) to facilitate pharmacokinetic/pharmacodynamic analyses in clinical trials. Paired plasma and whole-blood samples were collected by venipuncture, and whole blood was spotted on Whatman protein saver 903 cards. The methods were optimized for plasma and then validated for DBS. The analytical measuring range for quantification of rifapentine and its metabolite was 50 to 80,000 ng/ml in whole-blood DBS. The analyte was stable on the cards for 11 weeks with a desiccant at room temperature and protected from light. The method concordance for paired plasma and whole-blood DBS samples was determined after correcting for participant hematocrit or population-based estimates of bias from Bland-Altman plots. The application of either correction factor resulted in acceptable correlation between plasma and whole-blood DBS (Passing-Bablok regression corrected for hematocrit; y = 0.98x + 356). Concentrations of rifapentine may be determined from whole-blood DBS collected via venipuncture after normalization in order to account for the dilutional effects of red blood cells. Additional studies are focused on the application of this methodology to capillary blood collected by finger stick. The simplicity of processing, storage, shipping, and low blood volume makes whole-blood DBS attractive for rifapentine pharmacokinetic evaluations, especially in international and pediatric trials. PMID:25182637
Nijenhuis, Cynthia M; Huitema, Alwin D R; Marchetti, Serena; Blank, Christian; Haanen, John B A G; van Thienen, Johannes V; Rosing, Hilde; Schellens, Jan H M; Beijnen, Jos H
2016-10-01
Pharmacokinetic monitoring is increasingly becoming an important part of clinical care of tyrosine kinase inhibitor treatment. Vemurafenib is an oral tyrosine kinase inhibitor that inhibits mutated serine/threonine protein kinase B-Raf (BRAF) and is approved for the treatment of adult patients with BRAF V600 mutation-positive unresectable or metastatic melanoma. The aim of this study was to establish the relationship between dried blood spot (DBS) and plasma concentrations of vemurafenib to enable the use of DBS sampling, which is a minimally invasive form of sample collection. In total, 43 paired plasma and DBS samples (in duplicate) were obtained from 8 melanoma patients on vemurafenib therapy and were analyzed using high-performance liquid chromatography-tandem mass spectrometry. Plasma concentrations were predicted from the DBS concentrations using 2 methods: (1) individual hematocrit correction and blood cell-to-plasma partitioning and (2) the calculated slope explaining the relationship between DBS and plasma concentrations (without individual hematocrit correction). Vemurafenib DBS concentrations and plasma concentrations showed a strong correlation (r = 0.964), and the relationship could be described by ([vemurafenib]plasma = [vemurafenib]DBS /0.64). The predicted plasma concentrations were within ±20% of the analyzed plasma concentrations in 97% and 100% of the samples for the methods with and without hematocrit correction, respectively. In conclusion, DBS concentrations and plasma concentrations of vemurafenib are highly correlated. Plasma concentrations can be predicted from DBS concentration using the blood cell-to-plasma partition and the average hematocrit value of this cohort (0.40 L/L). DBS sampling for pharmacokinetic monitoring of vemurafenib treatment can be used in clinical practice. © 2016, The American College of Clinical Pharmacology.
Use of Dried Blood Spots to Elucidate Full-Length Transmitted/Founder HIV-1 Genomes
Salazar-Gonzalez, Jesus F.; Salazar, Maria G.; Tully, Damien C.; Ogilvie, Colin B.; Learn, Gerald H.; Allen, Todd M.; Heath, Sonya L.; Goepfert, Paul; Bar, Katharine J.
2016-01-01
Background Identification of HIV-1 genomes responsible for establishing clinical infection in newly infected individuals is fundamental to prevention and pathogenesis research. Processing, storage, and transportation of the clinical samples required to perform these virologic assays in resource-limited settings requires challenging venipuncture and cold chain logistics. Here, we validate the use of dried-blood spots (DBS) as a simple and convenient alternative to collecting and storing frozen plasma. Methods We performed parallel nucleic acid extraction, single genome amplification (SGA), next generation sequencing (NGS), and phylogenetic analyses on plasma and DBS. Results We demonstrated the capacity to extract viral RNA from DBS and perform SGA to infer the complete nucleotide sequence of the transmitted/founder (TF) HIV-1 envelope gene and full-length genome in two acutely infected individuals. Using both SGA and NGS methodologies, we showed that sequences generated from DBS and plasma display comparable phylogenetic patterns in both acute and chronic infection. SGA was successful on samples with a range of plasma viremia, including samples as low as 1,700 copies/ml and an estimated ∼50 viral copies per blood spot. Further, we demonstrated reproducible efficiency in gp160 env sequencing in DBS stored at ambient temperature for up to three weeks or at -20°C for up to five months. Conclusions These findings support the use of DBS as a practical and cost-effective alternative to frozen plasma for clinical trials and translational research conducted in resource-limited settings. PMID:27819061
McDade, Thomas W; Williams, Sharon; Snodgrass, J Josh
2007-11-01
Logistical constraints associated with the collection and analysis of biological samples in community-based settings have been a significant impediment to integrative, multilevel bio-demographic and biobehavioral research. However recent methodological developments have overcome many of these constraints and have also expanded the options for incorporating biomarkers into population-based health research in international as well as domestic contexts. In particular using dried blood spot (DBS) samples-drops of whole blood collected on filter paper from a simple finger prick-provides a minimally invasive method for collecting blood samples in nonclinical settings. After a brief discussion of biomarkers more generally, we review procedures for collecting, handling, and analyzing DBS samples. Advantages of using DBS samples-compared with venipuncture include the relative ease and low cost of sample collection, transport, and storage. Disadvantages include requirements for assay development and validation as well as the relatively small volumes of sample. We present the results of a comprehensive literature review of published protocols for analysis of DBS samples, and we provide more detailed analysis of protocols for 45 analytes likely to be of particular relevance to population-level health research. Our objective is to provide investigators with the information they need to make informed decisions regarding the appropriateness of blood spot methods for their research interests.
Lawson, Graham; Cocks, Elizabeth; Tanna, Sangeeta
2012-05-15
The use of blood spot collection cards was investigated as a means of obtaining small volume samples for the quantification of therapeutic drugs for assessing medication adherence. A liquid chromatography-high resolution TOF mass spectrometry (LC-HRMS) method, based on the measurement at the accurate mass to charge ratio of the target analyte, was used to ensure specificity for atenolol in the dried blood spot (DBS) samples. A working method was developed and validated. For the preparation of DBS samples whole blood spiked with analyte was used to produce 30 μl blood spots on specimen collection cards. A 5mm disc was cut from the dried blood spot and extracted using methanol:water (60:40, v/v) containing the internal standard, atenolol-d(7). Extracts were vortexed, sonicated and then centrifuged. Gradient chromatographic elution was achieved using an Ascentis Express C18 100mm×2.1mm column and a mobile phase flow rate of 0.2 ml/min and the column oven temperature at 30 °C. MS detection was carried out in electrospray positive ion mode for target ions at accurate mass m/z 267.1703 for atenolol and 274.2143 for the IS. Drug extraction efficiency from spiked blood spots was demonstrated to be 96±5% and the drug was stable in DBS for at least 10 weeks. The developed LC-HRMS method was linear within the tested calibration range of 25-1500 ng/ml and validation showed the accuracy (relative error) and precision (coefficient of variation) values were within the pre-defined limits of ≤ 5% at all concentrations with a limit of quantification of 25 ng/ml. Factors with potential to affect drug quantification measurements such as the matrix effects, volume of blood applied onto the collection card and effect of different sampling cards were investigated. The developed LC-HRMS method was applied to blood spots on sampling card taken from adult healthy volunteers previously administered a 50mg atenolol tablet and a DBS concentration-time profile was obtained for atenolol. Requiring only a micro volume (30 μl) blood sample for analysis, the developed DBS based assay has the potential to assess patient adherence to atenolol. Copyright © 2012 Elsevier B.V. All rights reserved.
Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status
Fallah, Elham; Peighambardoust, Seyed Hadi
2012-01-01
Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01). Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be¬tween these two methods was not statistically significant on a group level. Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932
Selva, Laura; Benmessaoud, Rachid; Lanaspa, Miguel; Jroundi, Imane; Moraleda, Cinta; Acacio, Sozinho; Iñigo, Melania; Bastiani, Alien; Monsonis, Manuel; Pallares, Roman; Bassat, Quique; Muñoz-Almagro, Carmen
2013-01-01
Background Dried blood spot (DBS) is a reliable blood collection method for storing samples at room temperature and easily transporting them. We have previously validated a Real-Time PCR for detection of Streptococcus pneumoniae in DBS. The objective of this study was to apply this methodology for the diagnosis of S. pneumoniae and Haemophilus influenzae b (Hib) in DBS samples of children with pneumonia admitted to two hospitals in Mozambique and Morocco. Methods Ply and wzg genes of S. pneumoniae and bexA gene of Hib, were used as targets of Real-Time PCR. 329 DBS samples of children hospitalized with clinical diagnosis of pneumonia were tested. Results Real-Time PCR in DBS allowed for a significant increase in microbiological diagnosis of S. pneumoniae and Hib. When performing blood bacterial culture, only ten isolates of S. pneumoniae and none of Hib were detected (3·0% positivity rate, IC95% 1·4-5·5%). Real-Time PCR from DBS samples increased the detection yield by 4x fold, as 30 S. pneumoniae and 11 Hib cases were detected (12·4% positivity rate, IC95% 9·0-16·5%; P<0·001). Conclusion Real-Time PCR applied in DBS may be a valuable tool for improving diagnosis and surveillance of pneumonia caused by S. pneumoniae or Hib in developing countries. PMID:24116190
Fragile X protein in newborn dried blood spots.
Adayev, Tatyana; LaFauci, Giuseppe; Dobkin, Carl; Caggana, Michele; Wiley, Veronica; Field, Michael; Wotton, Tiffany; Kascsak, Richard; Nolin, Sarah L; Glicksman, Anne; Hosmer, Nicole; Brown, W Ted
2014-10-28
The fragile X syndrome (FXS) results from mutation of the FMR1 gene that prevents expression of its gene product, FMRP. We previously characterized 215 dried blood spots (DBS) representing different FMR1 genotypes and ages with a Luminex-based immunoassay (qFMRP). We found variable FMRP levels in the normal samples and identified affected males by the drastic reduction of FMRP. Here, to establish the variability of expression of FMRP in a larger random population we quantified FMRP in 2,000 anonymous fresh newborn DBS. We also evaluated the effect of long term storage on qFMRP by retrospectively assaying 74 aged newborn DBS that had been stored for 7-84 months that included normal and full mutation individuals. These analyses were performed on 3 mm DBS disks. To identify the alleles associated with the lowest FMRP levels in the fresh DBS, we analyzed the DNA in the samples that were more than two standard deviations below the mean. Analysis of the fresh newborn DBS revealed a broad distribution of FMRP with a mean approximately 7-fold higher than that we previously reported for fresh DBS in normal adults and no samples whose FMRP level indicated FXS. DNA analysis of the lowest FMRP DBS showed that this was the low extreme of the normal range and included a female carrying a 165 CGG repeat premutation. In the retrospective study of aged newborn DBS, the FMRP mean of the normal samples was less than 30% of the mean of the fresh DBS. Despite the degraded signal from these aged DBS, qFMRP identified the FXS individuals. The assay showed that newborn DBS contain high levels of FMRP that will allow identification of males and potentially females, affected by FXS. The assay is also an effective screening tool for aged DBS stored for up to four years.
Downs, Jennifer A.; Corstjens, Paul L.A.M.; Mngara, Julius; Lutonja, Peter; Isingo, Raphael; Urassa, Mark; Kornelis, Dieuwke; van Dam, Govert J.
2015-01-01
Circulating Anodic Antigen (CAA) testing is a powerful, increasingly-used tool for diagnosis of active schistosome infection. We sought to determine the feasibility and reliability of measuring CAA in blood spots collected on Whatman 903 Protein Saver cards, which are the predominant filter papers used worldwide for dried blood spot (DBS) research and clinical care. CAA was eluted from blood spots collected from 19 individuals onto Whatman 903 cards in Mwanza, Tanzania, and the assay was optimized to achieve CAA ratios comparable to those obtained from the spots’ corresponding serum samples. The optimized assay was then used to determine the correlation of serum samples (n=16) with DBS from cards that had been stored for 8 years at ambient temperature.Using a DBS volume equivalent to approximately four times the quantity of serum, CAA testing in DBS had a sensitivity of 76% and a specificity of 79% compared to CAA testing in serum. CAA testing was reliable in samples eluted from Whatman 903 cards that had been stored for 8 years at ambient temperature. The overall kappa coefficient was 0.53 (standard error 0.17, p<0.001). We conclude that CAA can be reliably and accurately measured in DBS collected onto the filter paper that is most commonly used for clinical care and research, and that can be stored for prolonged periods of time. This finding opens new avenues for future work among more than 700 million individuals living in areas worldwide in which schistosomes are endemic. PMID:26149541
Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.
2016-01-01
To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691
Hemoglobin Adducts of Benzene Oxide in Neonatal and Adult Dried Blood Spots
Funk, William E.; Waidyanatha, Suramya; Chaing, Shu H.; Rappaport, Stephen M.
2010-01-01
Adducts of reactive chemicals with hemoglobin (Hb) or human serum albumin can be used as biomarkers of internal doses of carcinogens. Since dried blood spots (DBS) are easier to collect and store than conventional venous blood samples, they encourage applications of biomarkers of exposure in large epidemiology studies. Also, neonatal DBS can be used to investigate chemical exposures in utero. Here, we report a simple method to isolate Hb from DBS with high recovery and purity using the addition of ethanol to aqueous DBS extracts. To prove the concept that DBS-derived proteins can be used to assay for adducts, we measured Hb adducts of benzene oxide, a reactive metabolite of the ubiquitous air pollutant, benzene, in 9 neonatal and 9 adult DBS (from volunteer subjects), using a gas chromatography-mass spectrometry method that we had previously developed. For comparison, benzene oxide-Hb adducts (BO-Hb) were measured in the same 9 adult subjects, using Hb that had been isolated and purified using our conventional method for venous blood. The geometric mean BO-Hb levels in all DBS samples ranged from 27.7 to 33.1 pmol/g globin. Neither of the comparisons of mean (logged) BO-Hb levels between sources (adult conventional vs. adult DBS and adult DBS vs. newborn DBS) showed a significant difference. Based upon the estimated variance of the BO-Hb levels, we had 80% power to detect a 1.7-fold difference in geometric mean levels of BO-Hb in our samples of 9 subjects. PMID:18708378
Tron, Camille; Kloosterboer, Sanne M; van der Nagel, Bart C H; Wijma, Rixt A; Dierckx, Bram; Dieleman, Gwen C; van Gelder, Teun; Koch, Birgit C P
2017-08-01
Risperidone, aripiprazole, and pipamperone are antipsychotic drugs frequently prescribed for the treatment of comorbid behavioral problems in children with autism spectrum disorders. Therapeutic drug monitoring (TDM) could be useful to decrease side effects and to improve patient outcome. Dried blood spot (DBS) sample collection seems to be an attractive technique to develop TDM of these drugs in a pediatric population. The aim of this work was to develop and validate a DBS assay suitable for TDM and home sampling. Risperidone, 9-OH risperidone, aripiprazole, dehydroaripiprazole, and pipamperone were extracted from DBS and analyzed by ultra-high-performance liquid chromatography-tandem mass spectrometry using a C18 reversed-phase column with a mobile phase consisting of ammonium acetate/formic acid in water or methanol. The suitability of DBS for TDM was assessed by studying the influence of specific parameters: extraction solution, EDTA carryover, hematocrit, punching location, spot volume, and hemolysis. The assay was validated with respect to conventional guidelines for bioanalytical methods. The method was linear, specific without any critical matrix effect, and with a mean recovery around 90%. Accuracy and imprecision were within the acceptance criteria in samples with hematocrit values from 30% to 45%. EDTA or hemolysis did not skew the results, and no punching carryover was observed. No significant influence of the spot volume or the punch location was observed. The antipsychotics were all stable in DBS stored 10 days at room temperature and 1 month at 4 or -80°C. The method was successfully applied to quantify the 3 antipsychotics and their metabolites in patient samples. A UHPLC-MS/MS method has been successfully validated for the simultaneous quantification of risperidone, 9-OH risperidone, aripiprazole, dehydroaripiprazole, and pipamperone in DBS. The assay provided good analytical performances for TDM and clinical research applications.
Verplaetse, Ruth; Henion, Jack
2016-07-05
A workflow overcoming microsample collection issues and hematocrit (HCT)-related bias would facilitate more widespread use of dried blood spots (DBS). This report describes comparative results between the use of a pipet and a microfluidic-based sampling device for the creation of volumetric DBS. Both approaches were successfully coupled to HCT-independent, fully automated sample preparation and online liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis allowing detection of five stimulants in finger prick blood. Reproducible, selective, accurate, and precise responses meeting generally accepted regulated bioanalysis guidelines were observed over the range of 5-1000 ng/mL whole blood. The applied heated flow-through solvent desorption of the entire spot and online solid phase extraction (SPE) procedure were unaffected by the blood's HCT value within the tested range of 28.0-61.5% HCT. Enhanced stability for mephedrone on DBS compared to liquid whole blood was observed. Finger prick blood samples were collected using both volumetric sampling approaches over a time course of 25 h after intake of a single oral dose of phentermine. A pharmacokinetic curve for the incurred phentermine was successfully produced using the described validated method. These results suggest that either volumetric sample collection method may be amenable to field-use followed by fully automated, HCT-independent DBS-SPE-LC-MS/MS bioanalysis for the quantitation of these representative controlled substances. Analytical data from DBS prepared with a pipet and microfluidic-based sampling devices were comparable, but the latter is easier to operate, making this approach more suitable for sample collection by unskilled persons.
Lunven, Catherine; Turpault, Sandrine; Beyer, Yann-Joel; O'Brien, Amy; Delfolie, Astrid; Boyanova, Neli; Sanderink, Ger-Jan; Baldinetti, Francesca
2016-01-01
Background: Teriflunomide, a once-daily oral immunomodulator approved for treatment of relapsing-remitting multiple sclerosis, is eliminated slowly from plasma. If necessary to rapidly lower plasma concentrations of teriflunomide, an accelerated elimination procedure using cholestyramine or activated charcoal may be used. The current bioanalytical assay for determination of plasma teriflunomide concentration requires laboratory facilities for blood centrifugation and plasma storage. An alternative method, with potential for greater convenience, is dried blood spot (DBS) methodology. Analytical and clinical validations are required to switch from plasma to DBS (finger-prick sampling) methodology. Methods: Using blood samples from healthy subjects, an LC-MS/MS assay method for quantification of teriflunomide in DBS over a range of 0.01–10 mcg/mL was developed and validated for specificity, selectivity, accuracy, precision, reproducibility, and stability. Results were compared with those from the current plasma assay for determination of plasma teriflunomide concentration. Results: Method was specific and selective relative to endogenous compounds, with process efficiency ∼88%, and no matrix effect. Inaccuracy and imprecision for intraday and interday analyses were <15% at all concentrations tested. Quantification of teriflunomide in DBS assay was not affected by blood deposit volume and punch position within spot, and hematocrit level had a limited but acceptable effect on measurement accuracy. Teriflunomide was stable for at least 4 months at room temperature, and for at least 24 hours at 37°C with and without 95% relative humidity, to cover sampling, drying, and shipment conditions in the field. The correlation between DBS and plasma concentrations (R2 = 0.97), with an average blood to plasma ratio of 0.59, was concentration independent and constant over time. Conclusions: DBS sampling is a simple and practical method for monitoring teriflunomide concentrations. PMID:27015245
Bingley, Polly J; Rafkin, Lisa E; Matheson, Della; Steck, Andrea K; Yu, Liping; Henderson, Courtney; Beam, Craig A; Boulware, David C
2015-12-01
Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot-based screening to identify islet autoantibody-positive relatives potentially eligible for inclusion in prevention trials. Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies.
Taylor, Rachel R.; Hoffman, Keith L.; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L.; Christians, Uwe
2013-01-01
Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r2 > 0.99) and 27.4-20,000 ng/ml (r2 > 0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. PMID:23670126
Martial, Lisa C.; Aarnoutse, Rob E.; Schreuder, Michiel F.; Henriet, Stefanie S.; Brüggemann, Roger J. M.; Joore, Manuela A.
2016-01-01
Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling. PMID:27941974
Martial, Lisa C; Aarnoutse, Rob E; Schreuder, Michiel F; Henriet, Stefanie S; Brüggemann, Roger J M; Joore, Manuela A
2016-01-01
Dried blood spot (DBS) sampling for the purpose of therapeutic drug monitoring can be an attractive alternative for conventional blood sampling, especially in children. This study aimed to compare all costs involved in conventional sampling versus DBS home sampling in two pediatric populations: renal transplant patients and hemato-oncology patients. Total costs were computed from a societal perspective by adding up healthcare cost, patient related costs and costs related to loss of productivity of the caregiver. Switching to DBS home sampling was associated with a cost reduction of 43% for hemato-oncology patients (€277 to €158) and 61% for nephrology patients (€259 to €102) from a societal perspective (total costs) per blood draw. From a healthcare perspective, costs reduced with 7% for hemato-oncology patients and with 21% for nephrology patients. Total savings depend on the number of hospital visits that can be avoided by using home sampling instead of conventional sampling.
Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Camenzind, Alexander G.; Borchers, Christoph H.
2013-01-01
Dried blood spot (DBS) sampling, coupled with multiple reaction monitoring mass spectrometry (MRM-MS), is a well-established approach for quantifying a wide range of small molecule biomarkers and drugs. This sampling procedure is simpler and less-invasive than those required for traditional plasma or serum samples enabling collection by minimally trained personnel. Many analytes are stable in the DBS format without refrigeration, which reduces the cost and logistical challenges of sample collection in remote locations. These advantages make DBS sample collection desirable for advancing personalized medicine through population-wide biomarker screening. Here we expand this technology by demonstrating the first multiplexed method for the quantitation of endogenous proteins in DBS samples. A panel of 60 abundant proteins in human blood was targeted by monitoring proteotypic tryptic peptides and their stable isotope-labeled analogs by MRM. Linear calibration curves were obtained for 40 of the 65 peptide targets demonstrating multiple proteins can be quantitatively extracted from DBS collection cards. The method was also highly reproducible with a coefficient of variation of <15% for all 40 peptides. Overall, this assay quantified 37 proteins spanning a range of more than four orders of magnitude in concentration within a single 25 min LC/MRM-MS analysis. The protein abundances of the 33 proteins quantified in matching DBS and whole blood samples showed an excellent correlation, with a slope of 0.96 and an R2 value of 0.97. Furthermore, the measured concentrations for 80% of the proteins were stable for at least 10 days when stored at −20 °C, 4 °C and 37 °C. This work represents an important first step in evaluating the integration of DBS sampling with highly-multiplexed MRM for quantitation of endogenous proteins. PMID:23221968
Bertaso, Anna; Sorio, Daniela; Vandoros, Anthula; De Palo, Elio F; Bortolotti, Federica; Tagliaro, Franco
2016-10-01
Continued progress in chronic alcohol abuse investigation requires the development of less invasive procedures for screening purposes. The application of finger-prick and related dried blood spots (fpDBS) for carbohydrate deficient transferrin (CDT) detection appears suitable for this aim. Therefore, the goal of this project was to develop a screening method for CDT using fpDBS with CZE analysis. Blood samples prepared by finger-prick were placed on DBS cards and left to air dry; each dried fpDBS disc was shredded into small pieces and suspended in acid solution (60 μL of HCl 120 mmol/L). After centrifugation (10 min at 1500 × g), the collected sample was adjusted to pH 3.5. After an overnight incubation, the pH was neutralised and an iron rich solution was added. After 1 h, CZE analysis was carried out. A group of 47 individuals was studied. Parallel serum samples were collected from each investigated subject and the %CDT for each sample was measured using HPLC and CZE techniques. The fpDBS transferrin sialo isoform electropherograms were similar to those obtained with serum. Moreover, fpDBS CZE CDT percentage levels demonstrated significant statistical correlation with those obtained from serum for both HPLC and CZE %CDT (p < 0.01; r 2 = 0.8913 and 0.8976, respectively), with %CDT from 0.8 to 13.7% for fpDBS and from 0.7 to 12.7% for serum. The newly developed fpDBS procedure for CDT analysis provides a simple and inexpensive tool for use in population screening. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Kahraman, Mustafa; Laufer, Thomas; Backes, Christina; Schrörs, Hannah; Fehlmann, Tobias; Ludwig, Nicole; Kohlhaas, Jochen; Meese, Eckart; Wehler, Thomas; Bals, Robert; Keller, Andreas
2017-09-01
Different work flows have been proposed to use miRNAs as blood-borne biomarkers. In particular, the method used for collecting blood from patients can considerably influence the diagnostic results. We explored whether dried blood spots (DBSs) facilitate stable miRNA measurements and compared its technical stability with biological variability. First, we tested the stability of DBS samples by generating from 1 person 18 whole-genome-wide miRNA profiles of DBS samples that were exposed to different temperature and humidity conditions. Second, we investigated technical reproducibility by performing 7 replicates of DBS again from 1 person. Third, we investigated DBS samples from 53 patients with lung cancer undergoing different therapies. Across these 3 stages, 108 genome-wide miRNA profiles from DBS were generated and evaluated biostatistically. In the stability analysis, we observed that temperature and humidity had an overall limited influence on the miRNomes (average correlation between the different conditions of 0.993). Usage of a silica gel slightly diminished DBS' technical reproducibility. The 7 technical replicates had an average correlation of 0.996. The correlation with whole-blood PAXGene miRNomes of the same individual was remarkable (correlation of 0.88). Finally, evaluation of the samples from the 53 patients with lung cancer exposed to different therapies showed that the biological variations exceeded the technical variability significantly ( P < 0.0001), yielding 51 dysregulated miRNAs. We present a stable work flow for profiling of whole miRNomes on the basis of samples collected from DBS. Biological variations exceeded technical variations significantly. DBS-based miRNA profiles will potentially further the translational character of miRNA biomarker studies. © 2017 American Association for Clinical Chemistry.
Temesi, David; Swales, John; Keene, Warren; Dick, Samuel
2013-03-25
Procedures for drug monitoring based on Dried Blood Spot (DBS) sampling are gaining acceptance for an increasing number of clinical and preclinical applications, where ease of use, small sample requirement, and improved sample stability have been shown to offer advantages over blood tube sampling. However, to-date, the vast majority of this work has described the analysis of well characterized drugs. Using amitriptyline, clozapine, and their potentially labile N-oxide metabolites as model compounds, we consider the merits of using DBS for discovery pharmacokinetic (PK) studies where the metabolic fate of test compounds are often unknown. Both N-oxide metabolites reverted to parent compound under standard drying (2hr) and extraction conditions. Card type significantly affected the outcome, with 14% and 22% degradation occurring for clozapine-N-oxide and amitriptyline-N-oxide on a brand of untreated DBS cards, compared to 59 and 88% on a brand of treated DBS cards. Enrichment of the parent compound ex vivo leads to overestimation of circulating blood concentration and inaccurate determination of the PK profile. Copyright © 2012 Elsevier B.V. All rights reserved.
Chen, Hauh-Jyun Candy; Fan, Chih-Huang; Yang, Ya-Fen
2016-12-19
Dried blood spot (DBS) is an emerging microsampling technique for the bioanalysis of small molecules, including fatty acids, metabolites, drugs, and toxicants. DBS offers many advantages as a sample format including easy sample collection and cheap sample shipment. Hemoglobin adducts have been recognized as a suitable biomarker for monitoring chemical exposure. We previously reported that certain modified peptides in hemoglobin derived from reactive chlorine, nitrogen, and oxygen species are associated with factors including smoking, diabetes mellitus, and aging. However, the stability of these oxidation-induced modifications of hemoglobin remains unknown and whether they can be formed artifactually during storage of DBS. To answer these questions, globin extracted from the DBS cards was analyzed, and the stability of the modifications was evaluated. After storage of the DBS cards at 4 °C or room temperature up to 7 weeks, we isolated globin from a quarter of the spot every week. The extents of 11 sites and types of post-translational modifications (PTMs), including nitration and nitrosylation of tyrosine and oxidation of cysteine and methionine residues, in human hemoglobin were measured in the trypsin digest by nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) using selected reaction monitoring. The extents of all these PTMs are stable within 14 days when stored on DBS at room temperature and at 4 °C, while those from direct extraction of fresh blood are stable for at least 8 weeks when stored as an aqueous solution at -20 °C. Extraction of globin from a DBS card is of particular importance for hemolytic blood samples. To our knowledge, this is the first report on the stability of oxidative modifications of hemoglobin on DBSs, which are stable for 14 days under ambient conditions (room temperature, in air). Therefore, it is feasible and convenient to analyze these hemoglobin modifications from DBSs in studies involving large populations.
Nirogi, Ramakrishna; Ajjala, Devender Reddy; Kandikere, Vishwottam; Aleti, Raghupathi; Srikakolapu, SuryaRao; Vurimindi, Himabindu
2012-10-15
Deferasirox is an iron chelating agent for the treatment of transfusional iron over load in patients with chronic anemia. These anemic patients require close monitoring of the deferasirox exposures for ensuring its therapeutic efficacy. Dried blood spot (DBS) sampling methodology has the advantages of low volume of blood withdrawal and ease of transportation and storage over liquid blood methods. A LC-MS/MS based analytical method was developed using reversed phase column with gradient elution program and quantitated in MRM mode. Linearity range for the liquid blood was 1-1000 ng/mL and for DBS was 5-5000 ng/mL under similar mass spectrometry conditions. The method was validated with respective (M-H)(-) ions, m/z 372→118 for deferasirox and m/z 410→348 for fluvastatin (internal standard). The validated method was applied for the analysis of DBS samples from a rat pharmacokinetic study and results were compared against liquid blood samples from the same animal. The mean C(max) from DBS sample (1121 ng/mL) was comparable to mean C(max) found in blood samples (1015 ng/mL) at 2h after oral dose of deferasirox. All the other calculated pharmacokinetic parameters were quite comparable for both liquid blood and DBS samples. Copyright © 2012. Published by Elsevier B.V.
Déglon, Julien; Versace, François; Lauer, Estelle; Widmer, Christèle; Mangin, Patrice; Thomas, Aurélien; Staub, Christian
2012-06-01
Dried blood spots (DBS) sampling has gained popularity in the bioanalytical community as an alternative to conventional plasma sampling, as it provides numerous benefits in terms of sample collection and logistics. The aim of this work was to show that these advantages can be coupled with a simple and cost-effective sample pretreatment, with subsequent rapid LC-MS/MS analysis for quantitation of 15 benzodiazepines, six metabolites and three Z-drugs. For this purpose, a simplified offline procedure was developed that consisted of letting a 5-µl DBS infuse directly into 100 µl of MeOH, in a conventional LC vial. The parameters related to the DBS pretreatment, such as extraction time or internal standard addition, were investigated and optimized, demonstrating that passive infusion in a regular LC vial was sufficient to quantitatively extract the analytes of interest. The method was validated according to international criteria in the therapeutic concentration ranges of the selected compounds. The presented strategy proved to be efficient for the rapid analysis of the selected drugs. Indeed, the offline sample preparation was reduced to a minimum, using a small amount of organic solvent and consumables, without affecting the accuracy of the method. Thus, this approach enables simple and rapid DBS analysis, even when using a non-DBS-dedicated autosampler, while lowering the costs and environmental impact.
Verplaetse, Ruth; Henion, Jack
2016-01-01
Opioids are well known, widely used painkillers. Increased stability of opioids in the dried blood spot (DBS) matrix compared to blood/plasma has been described. Other benefits provided by DBS techniques include point-of-care collection, less invasive micro sampling, more economical shipment, and convenient storage. Current methodology for analysis of micro whole blood samples for opioids is limited to the classical DBS workflow, including tedious manual punching of the DBS cards followed by extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. The goal of this study was to develop and validate a fully automated on-line sample preparation procedure for the analysis of DBS micro samples relevant to the detection of opioids in finger prick blood. To this end, automated flow-through elution of DBS cards was followed by on-line solid-phase extraction (SPE) and analysis by LC-MS/MS. Selective, sensitive, accurate, and reproducible quantitation of five representative opioids in human blood at sub-therapeutic, therapeutic, and toxic levels was achieved. The range of reliable response (R(2) ≥0.997) was 1 to 500 ng/mL whole blood for morphine, codeine, oxycodone, hydrocodone; and 0.1 to 50 ng/mL for fentanyl. Inter-day, intra-day, and matrix inter-lot accuracy and precision was less than 15% (even at lower limits of quantitation (LLOQ) level). The method was successfully used to measure hydrocodone and its major metabolite norhydrocodone in incurred human samples. Our data support the enormous potential of DBS sampling and automated analysis for monitoring opioids as well as other pharmaceuticals in both anti-doping and pain management regimens. Copyright © 2015 John Wiley & Sons, Ltd.
Tang, Ning; Pahalawatta, Vihanga; Frank, Andrea; Bagley, Zowie; Viana, Raquel; Lampinen, John; Leckie, Gregor; Huang, Shihai; Abravaya, Klara; Wallis, Carole L
2017-07-01
HIV RNA suppression is a key indicator for monitoring success of antiretroviral therapy. From a logistical perspective, viral load (VL) testing using Dried Blood Spots (DBS) is a promising alternative to plasma based VL testing in resource-limited settings. To evaluate the analytical and clinical performance of the Abbott RealTime HIV-1 assay using a fully automated one-spot DBS sample protocol. Limit of detection (LOD), linearity, lower limit of quantitation (LLQ), upper limit of quantitation (ULQ), and precision were determined using serial dilutions of HIV-1 Virology Quality Assurance stock (VQA Rush University), or HIV-1-containing armored RNA, made in venous blood. To evaluate correlation, bias, and agreement, 497 HIV-1 positive adult clinical samples were collected from Ivory Coast, Uganda and South Africa. For each HIV-1 participant, DBS-fingerprick, DBS-venous and plasma sample results were compared. Correlation and bias values were obtained. The sensitivity and specificity were analyzed at a threshold of 1000 HIV-1 copies/mL generated using the standard plasma protocol. The Abbott HIV-1 DBS protocol had an LOD of 839 copies/mL, a linear range from 500 to 1×10 7 copies/mL, an LLQ of 839 copies/mL, a ULQ of 1×10 7 copies/mL, and an inter-assay SD of ≤0.30 log copies/mL for all tested levels within this range. With clinical samples, the correlation coefficient (r value) was 0.896 between DBS-fingerprick and plasma and 0.901 between DBS-venous and plasma, and the bias was -0.07 log copies/mL between DBS-fingerprick and plasma and -0.02 log copies/mL between DBS-venous and plasma. The sensitivity of DBS-fingerprick and DBS-venous was 93%, while the specificity of both DBS methods was 95%. The results demonstrated that the Abbott RealTime HIV-1 assay with DBS sample protocol is highly sensitive, specific and precise across a wide dynamic range and correlates well with plasma values. The Abbott RealTime HIV-1 assay with DBS sample protocol provides an alternative sample collection and transfer option in resource-limited settings and expands the utility of a viral load test to monitor HIV-1 ART treatment for infected patients. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
Taylor, Rachel R; Hoffman, Keith L; Schniedewind, Björn; Clavijo, Claudia; Galinkin, Jeffrey L; Christians, Uwe
2013-09-01
Acetaminophen (paracetamol, N-(4-hydroxyphenyl) acetamide) is one of the most commonly prescribed drugs for the management of pain in children. Quantification of acetaminophen in pre-term and term neonates and small children requires the availability of highly sensitive assays in small volume blood samples. We developed and validated an LC-MS/MS assay for the quantification of acetaminophen in human plasma, cerebro-spinal fluid (CSF) and dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the deuterated internal standard were the only manual steps. Extracted samples were analyzed on a Kinetex 2.6 μm PFP column using an acetonitrile/formic acid gradient. The analytes were detected in the positive multiple reaction mode. Alternatively, DBS were automatically processed using direct desorption in a sample card and preparation (SCAP) robotic autosampler in combination with online extraction. The range of reliable response in plasma and CSF was 3.05-20,000 ng/ml (r(2)>0.99) and 27.4-20,000 ng/ml (r(2)>0.99) for DBS (manual extraction and automated direct desorption). Inter-day accuracy was always within 85-115% and inter-day precision for plasma, CSF and manually extracted DBS were less than 15%. Deming regression analysis comparing 167 matching pairs of plasma and DBS samples showed a correlation coefficient of 0.98. Bland Altman analysis indicated a 26.6% positive bias in DBS, most likely reflecting the blood: plasma distribution ratio of acetaminophen. DBS are a valid matrix for acetaminophen pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Dried blood spots for the enzymatic diagnosis of lysosomal storage diseases in dogs and cats.
Sewell, Adrian C; Haskins, Mark E; Giger, Urs
2012-12-01
In people, lysosomal storage diseases (LSD) can be diagnosed by assaying enzyme activities in dried blood spots (DBS). The aim of this study was to evaluate the feasibility of using DBS samples from dogs and cats to measure lysosomal enzymatic activities and diagnose LSD. Drops of fresh whole blood collected in EDTA from dogs and cats with known or suspected LSD and from clinically healthy dogs and cats were placed on neonatal screening cards, dried, and mailed to the Metabolic Laboratory, University Children's Hospital, Frankfurt, Germany. Activities of selected lysosomal enzymes were measured using fluorescent substrates in a 2-mm diameter disk (~2.6 μL blood) punched from the DBS. Results were expressed as nmol substrate hydrolyzed per mL of blood per minute or hour. Reference values were established for several lysosomal enzyme activities in DBS from dogs and cats; for most enzymes, activities were higher than those published for human samples. Activities of β-glucuronidase, N-acetylglucosamine-4-sulfatase (arylsulfatase B), α-mannosidase, α-galactosidase, α-fucosidase, and hexosaminidase A were measureable in DBS from healthy cats and dogs; α-iduronidase activity was measureable only in cats. In samples from animals with LSD, markedly reduced activity of a specific enzyme was found. In contrast, in samples from cats affected with mucolipidosis II, activities of lysosomal enzymes were markedly increased. Measurement of lysosomal enzyme activities in DBS provides an inexpensive, simple, and convenient method to screen animals for suspected LSD and requires only a small sample volume. For diseases in which the relevant enzyme activity can be measured in DBS, a specific diagnosis can be made. © 2012 American Society for Veterinary Clinical Pathology.
Monleau, Marjorie; Eymard-Duvernay, Sabrina; Dagnra, Anoumou; Kania, Dramane; Ngo-Giang-Huong, Nicole; Touré-Kane, Coumba; Truong, Lien X. T.; Chaix, Marie-Laure; Delaporte, Eric; Ayouba, Ahidjo; Peeters, Martine
2014-01-01
Dried blood spots (DBS) can be used in developing countries to alleviate the logistic constraints of using blood plasma specimens for viral load (VL) and HIV drug resistance (HIVDR) testing, but they should be assessed under field conditions. Between 2009 and 2011, we collected paired plasma-DBS samples from treatment-experienced HIV-1-infected adults in Burkina Faso, Cameroon, Senegal, Togo, Thailand, and Vietnam. The DBS were stored at an ambient temperature for 2 to 4 weeks and subsequently at −20°C before testing. VL testing was performed on the plasma samples and DBS using locally available methods: the Abbott m2000rt HIV-1 test, generic G2 real-time PCR, or the NucliSENS EasyQ version 1.2 test. In the case of virological failure (VF), i.e., a plasma VL of ≥1,000 copies/ml, HIVDR genotyping was performed on paired plasma-DBS samples. Overall, we compared 382 plasma-DBS sample pairs for DBS VL testing accuracy. The sensitivities of the different assays in different laboratories for detecting VF using DBS varied from 75% to 100% for the m2000rt test in labs B, C, and D, 91% to 93% for generic G2 real-time PCR in labs A and F, and 85% for the NucliSENS test in lab E. The specificities varied from 82% to 97% for the m2000rt and NucliSENS tests and reached only 60% for the generic G2 test. The NucliSENS test showed good agreement between plasma and DBS VL but underestimated the DBS VL. The lowest agreement was observed for the generic G2 test. Genotyping was successful for 96/124 (77%) DBS tested, and 75/96 (78%) plasma-DBS pairs had identical HIVDR mutations. Significant discrepancies in resistance interpretations were observed in 9 cases, 6 of which were from the same laboratory. DBS can be successfully used as an alternative to blood plasma samples for routine VL and HIVDR monitoring in African and Asian settings. However, the selection of an adequate VL measurement method and the definition of the VF threshold should be considered, and laboratory performance should be monitored. PMID:24478491
Quantitation of Tenofovir and Emtricitabine in Dried Blood Spots (DBS) with LC-MS/MS
Zheng, Jia-Hua; Guida, Louis A; Rower, Caitlin; Castillo-Mancilla, Jose; Meditz, Amie; Klein, Brandon; Kerr, Becky Jo; Langness, Jacob; Bushman, Lane; Kiser, Jennifer; Anderson, Peter L.
2013-01-01
A reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of tenofovir (TFV) and emtricitabine (FTC) in dried blood spots (DBS) from human whole blood was developed and validated. Whole blood samples were spotted, dried, and a 3mm punch was extracted with methanol for analysis by LC-MS/MS utilizing stable isotope labeled internal standards. The assay was validated over the range of 2.5ng/mL to 1,000ng/mL for TFV and 2.5ng/mL to 5,000ng/mL for FTC. The method was accurate (within ± 15% of control) and precise (coefficient of variation ≤ 15%) for hematocrit concentrations ranging from 25% to 76%; using edge punches versus center punches; and spot volumes of 10µL to 50µL. Analytes were stable for five freeze/thaw cycles and up to 6 days at room temperature, whereas long-term storage required −20°C or −80°C. Comparison of TFV and FTC in DBS versus plasma yielded r2 ≥ 0.96, indicating that DBS can be used as a plasma alternative for pharmacokinetic analyses in vivo. PMID:24055850
Browne, J L; Schielen, P C J I; Belmouden, I; Pennings, J L A; Klipstein-Grobusch, K
2015-06-01
The objectives of the article is to compare pregnancy-associated plasma protein A (PAPP-A) and free β-subunit of human chorionic gonadotropin (β-hCG) concentrations in dried blood spots (DBSs) with serum of samples obtained from a public hospital in a low-resource setting and to evaluate their stability. Serum and DBS samples were obtained by venipuncture and finger prick from 50 pregnant participants in a cohort study in a public hospital in Accra, Ghana. PAPP-A and β-hCG concentrations from serum and DBS were measured with an AutoDELFIA® (PerkinElmer, PerkinElmer, Turku, Finland) automatic immunoassay. Correlation and Passing-Bablok regression analyses were performed to compare marker levels. High correlation (>0.9) was observed for PAPP-A and β-hCG levels between various sampling techniques. The β-hCG concentration was stable between DBS and serum, PAPP-A concentration consistently lower in DBS. Our findings suggest that β-hCG can be reliably collected from DBS in low-resource tropical settings. The exact conditions of the clinical workflow necessary for reliable PAPP-A measurement in these settings need to be further developed in the future. These findings could have implications for prenatal screening programs feasibility in low-income and middle-income countries, as DBS provides an alternative minimally invasive sampling method, with advantages in sampling technique, stability, logistics, and potential application in low-resource settings. © 2015 John Wiley & Sons, Ltd.
Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M
2017-11-01
Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.
Capiau, Sara; Wilk, Leah S; De Kesel, Pieter M M; Aalders, Maurice C G; Stove, Christophe P
2018-02-06
The hematocrit (Hct) effect is one of the most important hurdles currently preventing more widespread implementation of quantitative dried blood spot (DBS) analysis in a routine context. Indeed, the Hct may affect both the accuracy of DBS methods as well as the interpretation of DBS-based results. We previously developed a method to determine the Hct of a DBS based on its hemoglobin content using noncontact diffuse reflectance spectroscopy. Despite the ease with which the analysis can be performed (i.e., mere scanning of the DBS) and the good results that were obtained, the method did require a complicated algorithm to derive the total hemoglobin content from the DBS's reflectance spectrum. As the total hemoglobin was calculated as the sum of oxyhemoglobin, methemoglobin, and hemichrome, the three main hemoglobin derivatives formed in DBS upon aging, the reflectance spectrum needed to be unmixed to determine the quantity of each of these derivatives. We now simplified the method by only using the reflectance at a single wavelength, located at a quasi-isosbestic point in the reflectance curve. At this wavelength, assuming 1-to-1 stoichiometry of the aging reaction, the reflectance is insensitive to the hemoglobin degradation and only scales with the total amount of hemoglobin and, hence, the Hct. This simplified method was successfully validated. At each quality control level as well as at the limits of quantitation (i.e., 0.20 and 0.67) bias, intra- and interday imprecision were within 10%. Method reproducibility was excellent based on incurred sample reanalysis and surpassed the reproducibility of the original method. Furthermore, the influence of the volume spotted, the measurement location within the spot, as well as storage time and temperature were evaluated, showing no relevant impact of these parameters. Application to 233 patient samples revealed a good correlation between the Hct determined on whole blood and the predicted Hct determined on venous DBS. The bias obtained with Bland and Altman analysis was -0.015 and the limits of agreement were -0.061 and 0.031, indicating that the simplified, noncontact Hct prediction method even outperforms the original method. In addition, using caffeine as a model compound, it was demonstrated that this simplified Hct prediction method can effectively be used to implement a Hct-dependent correction factor to DBS-based results to alleviate the Hct bias.
Villanelli, Fabio; Giocaliere, Elisa; Malvagia, Sabrina; Rosati, Anna; Forni, Giulia; Funghini, Silvia; Shokry, Engy; Ombrone, Daniela; Della Bona, Maria Luisa; Guerrini, Renzo; la Marca, Giancarlo
2015-02-02
Phenytoin (PHT) is one of the most commonly used anticonvulsant drugs for the treatment of epilepsy and bipolar disorders. The large amount of plasma required by conventional methods for drug quantification makes mass spectrometry combined with dried blood spot (DBS) sampling crucial for pediatric patients where therapeutic drug monitoring or pharmacokinetic studies may be difficult to realize. DBS represents a new convenient sampling support requiring minimally invasive blood drawing and providing long-term stability of samples and less expensive shipment and storage. The aim of this study was to develop a LC-MS/MS method for the quantification of PHT on DBS. This analytical method was validated and gave good linearity (r(2)=0.999) in the range of 0-100mg/l. LOQ and LOD were 1.0mg/l and 0.3mg/l, respectively. The drug extraction from paper was performed in a few minutes using a mixture composed of organic solvent for 80%. The recovery ranged from 85 to 90%; PHT in DBS showed to be stable at different storage temperatures for one month. A good correlation was also obtained between PHT plasma and DBS concentrations. This method is both precise and accurate and appears to be particularly suitable to monitor treatment with a simple and convenient sample collection procedure. Copyright © 2014 Elsevier B.V. All rights reserved.
Colson, K Ellicott; Potter, Alan; Conde-Glez, Carlos; Hernandez, Bernardo; Ríos-Zertuche, Diego; Zúñiga-Brenes, Paola; Iriarte, Emma; Mokdad, Ali H
2015-09-01
Seroepidemiological monitoring of population immunity to vaccine-preventable diseases is critical to prevent future outbreaks. Dried blood spots (DBS), drops of capillary blood dried on filter paper, are an affordable, minimally invasive alternative to venipuncture for collecting blood in field settings. However, few proven methods exist to analyze DBS for the presence of protective antibodies. This study validates a novel technique for measuring measles-specific immunoglobulin G (IgG) in capillary DBS using a commercial ELISA. The predictive performance of a new method for analyzing DBS was tested by comparing matched serum and DBS samples from 50 children. The accuracy, precision, and reliability of the procedure were evaluated, and the optimal cut points to classify positive and negative samples were determined. The method was then applied to 1,588 DBS collected during a large survey of children in Mexico and Nicaragua. Measles-specific IgG in serum samples were 62% negative, 10% equivocal, and 28% positive. In comparisons with matched serum, DBS results were 100% sensitive and 96 · 8% specific, and agreed in 46 of 50 (92%) cases. The inter-assay and intra-assay coefficients of variation from kit-provided controls were greater than desired (24.8% and 8.4%, respectively). However, in predictive simulations the average misclassification was only 3.9%. Procedures were found to be acceptable to surveyors and participants. Analyzing DBS collected in low-resources settings is a feasible and accurate means of measuring population immunity to measles and should be used to generate objective measures of health status and health system performance. © 2015 Wiley Periodicals, Inc.
Déglon, Julien; Thomas, Aurélien; Daali, Youssef; Lauer, Estelle; Samer, Caroline; Desmeules, Jules; Dayer, Pierre; Mangin, Patrice; Staub, Christian
2011-01-25
This paper illustrates the development of an automated system for the on-line bioanalysis of dried blood spots (on-line DBS). In this way, a prototype was designed for integration into a conventional LC/MS/MS, allowing the successive extraction of 30 DBS toward the analytical system without any sample pretreatment. The developed method was assessed for the DBS analysis of flurbiprofen (FLB) and its metabolite 4-hydroxyflurbiprofen (OH-FLB) in human whole blood (i.e. 5 μL). The automated procedure was fully validated based on international criteria and showed good precision, trueness, and linearity over the expected concentration range (from 10 to 1000 ng/mL and 100 to 10,000 ng/mL for OH-FLB and FLB respectively). Furthermore, the prototype showed good results in terms of recovery and carry-over. Stability of both analytes on filter paper was also investigated and the results suggested that DBS could be stored at ambient temperature for over 1 month. The on-line DBS automated system was then successfully applied to a pharmacokinetic study performed on healthy male volunteers after oral administration of a single 50-mg dose of FLB. Additionally, a comparison between finger capillary DBS and classic venous plasma concentrations was investigated. A good correlation was observed, demonstrating the complementarity of both sampling forms. The automated system described in this article represents an efficient tool for the LC/MS/MS analysis of DBS samples in many bioanalytical applications. Copyright © 2010 Elsevier B.V. All rights reserved.
Schwartz, Alanna; Baidjoe, Amrish; Rosenthal, Philip J; Dorsey, Grant; Bousema, Teun; Greenhouse, Bryan
2015-05-01
Extraction and amplification of DNA from dried blood spots (DBS) collected in field studies is commonly used for detection of Plasmodium falciparum. However, there have been few systematic efforts to determine the effects of storage and extraction methods on the sensitivity of DNA amplification. We investigated the effects of storage conditions, length of storage, and DNA extraction methods on amplification via three PCR-based assays using field samples and laboratory controls. Samples stored as DBS for 2 or more years at ambient temperature showed a significant loss of sensitivity that increased with time; after 10 years only 10% samples with parasite densities > 1,000 parasites/μL were detectable by nested polymerase chain reaction (PCR). Conversely, DBS and extracted DNA stored at -20°C showed no loss of sensitivity with time. Samples with low parasite densities amplified more successfully with saponin/Chelex compared with spin-column-based extraction, though the latter method performed better on samples with higher parasite densities stored for 2 years at ambient temperature. DNA extracted via both methods was stable after 20 freeze-thaw cycles. Our results suggest that DBS should be stored at -20°C or extracted immediately, especially if anticipating 2 or more years of storage. © The American Society of Tropical Medicine and Hygiene.
Schwartz, Alanna; Baidjoe, Amrish; Rosenthal, Philip J.; Dorsey, Grant; Bousema, Teun; Greenhouse, Bryan
2015-01-01
Extraction and amplification of DNA from dried blood spots (DBS) collected in field studies is commonly used for detection of Plasmodium falciparum. However, there have been few systematic efforts to determine the effects of storage and extraction methods on the sensitivity of DNA amplification. We investigated the effects of storage conditions, length of storage, and DNA extraction methods on amplification via three PCR-based assays using field samples and laboratory controls. Samples stored as DBS for 2 or more years at ambient temperature showed a significant loss of sensitivity that increased with time; after 10 years only 10% samples with parasite densities > 1,000 parasites/μL were detectable by nested polymerase chain reaction (PCR). Conversely, DBS and extracted DNA stored at −20°C showed no loss of sensitivity with time. Samples with low parasite densities amplified more successfully with saponin/Chelex compared with spin-column-based extraction, though the latter method performed better on samples with higher parasite densities stored for 2 years at ambient temperature. DNA extracted via both methods was stable after 20 freeze-thaw cycles. Our results suggest that DBS should be stored at −20°C or extracted immediately, especially if anticipating 2 or more years of storage. PMID:25758652
Antunes, Marina Venzon; Charão, Mariele Feiffer; Linden, Rafael
2016-09-01
Therapeutic drug monitoring (TDM) relays in the availability of specialized laboratory assays, usually available in reference centers that are not accessible to all patients. In this context, there is a growing interest in the use of dried blood spot (DBS) sampling, usually obtained from finger pricks, which allows simple and cost-effective logistics in many settings, particularly in Developing Countries. The use of DBS assays to estimate plasma concentrations is highly dependent on the hematocrit of the blood, as well as the particular characteristics of the measured analyte. DBS assays require specific validation assays, most of them are related to hematocrit effects. In the present manuscript, the application of mass spectrometric assays for determination of drugs for TDM purposes in the last ten years is reviewed, as well as the particular validation assays for new DBS methods. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Multiple Reaction Monitoring Enables Precise Quantification of 97 Proteins in Dried Blood Spots*
Chambers, Andrew G.; Percy, Andrew J.; Yang, Juncong; Borchers, Christoph H.
2015-01-01
The dried blood spot (DBS) methodology provides a minimally invasive approach to sample collection and enables room-temperature storage for most analytes. DBS samples have successfully been analyzed by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS) to quantify a large range of small molecule biomarkers and drugs; however, this strategy has only recently been explored for MS-based proteomics applications. Here we report the development of a highly multiplexed MRM assay to quantify endogenous proteins in human DBS samples. This assay uses matching stable isotope-labeled standard peptides for precise, relative quantification, and standard curves to characterize the analytical performance. A total of 169 peptides, corresponding to 97 proteins, were quantified in the final assay with an average linear dynamic range of 207-fold and an average R2 value of 0.987. The total range of this assay spanned almost 5 orders of magnitude from serum albumin (P02768) at 18.0 mg/ml down to cholinesterase (P06276) at 190 ng/ml. The average intra-assay and inter-assay precision for 6 biological samples ranged from 6.1–7.5% CV and 9.5–11.0% CV, respectively. The majority of peptide targets were stable after 154 days at storage temperatures from −20 °C to 37 °C. Furthermore, protein concentration ratios between matching DBS and whole blood samples were largely constant (<20% CV) across six biological samples. This assay represents the highest multiplexing yet achieved for targeted protein quantification in DBS samples and is suitable for biomedical research applications. PMID:26342038
Impact of various factors on radioactivity distribution in different DBS papers.
Ren, Xiao; Paehler, Tobias; Zimmer, Manfred; Guo, Zuyu; Zane, Patricia; Emmons, Gary T
2010-08-01
Dried blood spot (DBS) sampling could potentially become the preferred blood collection technique in toxicological and clinical studies. Autoradiography was performed to study compound distribution within a dbs under different conditions using five papers, 31ETF, Grade 226, 903(®), FTA(®) and FTA(®) Elute. The results showed an uneven distribution in all papers with common distribution patterns regardless of compounds: decreased concentrations along the edge, the volcano effect in the middle and the speckle pattern in the center. Treated papers were more readily influenced by environmental factors. Autoradiography enables visualization of a compound's distribution and can guide bioanalytical assay development by allowing convenient evaluation of factors, such as choice of paper, spotting volume, punch size, punch location, temperature and humidity.
Li, Wenkui; Doherty, John P; Kulmatycki, Kenneth; Smith, Harold T; Tse, Francis Ls
2012-06-01
In support of a pilot clinical trial using acetaminophen as the model compound to assess dried blood spot (DBS) sampling as the method for clinical pharmacokinetic sample collection, a novel sensitive LC-MS/MS method was developed and validated for the simultaneous determination of acetaminophen and its major metabolites, acetaminophen glucuronide and sulfate, in human DBS samples collected by subjects via fingerprick. The validated assay dynamic range was from 50.0 to 5000 ng/ml for each compound using a 1/8´´ (3-mm) disc punched from a DBS sample. Baseline separation of the three analytes was achieved to eliminate the possible impact of insource fragmentation of the conjugated metabolites on the analysis of the parent. The overall extraction efficiency was from 61.3 to 78.8% for the three analytes by direct extraction using methanol. The validated method was successfully implemented in the pilot clinical study with the obtained pharmacokinetic parameters in agreement with the values reported in literature.
Neogi, Ujjwal; Gupta, Soham; Rodridges, Rashmi; Sahoo, Pravat Nalini; Rao, Shwetha D.; Rewari, Bharat B.; Shastri, Suresh; De Costa, Ayesha; Shet, Anita
2012-01-01
Background & objectives: Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. Methods: Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. Results: The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (−0.21 to +0.8 log10 copies/ml). The mean difference was 0.29 log10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting Interpretation & conclusions: The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally. PMID:23391790
Mbida, André Dieudonné; Sosso, Samuel; Flori, Pierre; Saoudin, Henia; Lawrence, Philip; Monny-Lobé, Marcel; Oyono, Yves; Ndzi, Edward; Cappelli, Giulia; Lucht, Frédéric; Pozzetto, Bruno; Oukem-Boyer, Odile Ouwe Missi; Bourlet, Thomas
2009-09-01
This study aimed to evaluate the use of dried blood spots (DBSs) and dried plasma spots (DPSs) locally collected in 2 rural dispensaries in Cameroon for the quantification of HIV-1 RNA. Forty-one subjects were sampled and spots of whole blood and plasma were deposited onto Whatman 903 cards and dried at ambient temperature under local conditions. Two sets of DBS and DPS cards were done per patient. The rest of the liquid plasma (LP) was frozen until use. LPs were tested at the "Chantal Biya" International Reference Centre (Yaoundé, Cameroon) by the Abbott Real-Time HIV-1 assay (Abbott Molecular Diagnostics, Wiesbaden, Germany). One series of DBS and DPS was transported and tested between 2 and 6 weeks later at the Virology Laboratory of Saint-Etienne (France). The second series was routed by mail and tested after up to 3 months of storage at ambient temperature. From the first series, the correlation rate between viral loads obtained from LP and DBS, and from LP and DPS, was 0.98 and 0.99, respectively; specificity of DBS and DPS results was 100%. The results obtained from the second series indicate a great stability of DBS after long-term storage. This study demonstrates that DBSs collected under local conditions in resource-limited settings are suitable for the differed quantification of HIV-1 RNA.
Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R; Salman, Sam; Marshall, Lewis; Davis, Timothy M E; Batty, Kevin T; Manning, Laurens
2017-08-01
Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at -20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. Copyright © 2017 American Society for Microbiology.
Page-Sharp, Madhu; Coward, Jonathan; Moore, Brioni R.; Marshall, Lewis; Batty, Kevin T.
2017-01-01
ABSTRACT Rheumatic heart disease (RHD) remains an important global health challenge. Administration of benzathine penicillin (BPG) every 3 to 4 weeks is recommended as a secondary prophylaxis to prevent recurrent episodes of acute rheumatic fever and subsequent RHD. Following intramuscular injection, BPG is hydrolyzed to penicillin G (benzylpenicillin). However, little is known of the pharmacokinetics (PK) of BPG in pediatric populations at high risk of RHD or of the pharmacokinetic-pharmacodynamic relationship between penicillin exposure and clinically relevant outcomes. Dried blood spot (DBS) assays can facilitate PK studies in situations where frequent venous blood sampling is logistically difficult. A liquid chromatography-mass spectroscopy assay for penicillin G in plasma and DBS was developed and validated. Application of the DBS assay for PK studies was confirmed using samples from adult patients receiving penicillin as part of an infection management plan. The limit of quantification for penicillin G in DBS was 0.005 mg/liter. Penicillin G is stable in DBS for approximately 12 h at room temperature (22°C), 6 days at 4°C, and >1 month at −20°C. Plasma and DBS penicillin G concentrations for patients receiving BPG and penicillin G given via bolus doses correlated well and had comparable time-concentration profiles. There was poor correlation for patients receiving penicillin via continuous infusions, perhaps as a result of the presence of residual penicillin in the peripherally inserted central catheter, from which the plasma samples were collected. The present DBS penicillin G assay can be used as a surrogate for plasma concentrations to provide valid PK data for studies of BPG and other penicillin preparations developed to prevent rheumatic fever and RHD. PMID:28559267
Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina
2014-10-01
The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
De Kesel, Pieter M M; Capiau, Sara; Stove, Veronique V; Lambert, Willy E; Stove, Christophe P
2014-10-01
Although dried blood spot (DBS) sampling is increasingly receiving interest as a potential alternative to traditional blood sampling, the impact of hematocrit (Hct) on DBS results is limiting its final breakthrough in routine bioanalysis. To predict the Hct of a given DBS, potassium (K(+)) proved to be a reliable marker. The aim of this study was to evaluate whether application of an algorithm, based upon predicted Hct or K(+) concentrations as such, allowed correction for the Hct bias. Using validated LC-MS/MS methods, caffeine, chosen as a model compound, was determined in whole blood and corresponding DBS samples with a broad Hct range (0.18-0.47). A reference subset (n = 50) was used to generate an algorithm based on K(+) concentrations in DBS. Application of the developed algorithm on an independent test set (n = 50) alleviated the assay bias, especially at lower Hct values. Before correction, differences between DBS and whole blood concentrations ranged from -29.1 to 21.1%. The mean difference, as obtained by Bland-Altman comparison, was -6.6% (95% confidence interval (CI), -9.7 to -3.4%). After application of the algorithm, differences between corrected and whole blood concentrations lay between -19.9 and 13.9% with a mean difference of -2.1% (95% CI, -4.5 to 0.3%). The same algorithm was applied to a separate compound, paraxanthine, which was determined in 103 samples (Hct range, 0.17-0.47), yielding similar results. In conclusion, a K(+)-based algorithm allows correction for the Hct bias in the quantitative analysis of caffeine and its metabolite paraxanthine.
Stability of benzodiazepines and cocaine in blood spots stored on filter paper.
Alfazil, Abdulkareem A; Anderson, Robert A
2008-09-01
Previous studies have shown that drug concentrations in blood can change during storage, especially at room temperature, but even labile drugs such as cocaine may be stable in dried blood spots (DBS). A new method has been developed for the analysis of hydrolytically labile drugs in blood spots on filter paper in order to assess their degradation during a storage period of one month. The drugs selected included flunitrazepam, temazepam, oxazepam, lorazepam, nitrazepam, diazepam, and cocaine. A Guthrie card 903 was spotted with 100 microL of blood containing the drugs at concentrations of 1000 ng/mL and left overnight to dry at room temperature. The filter paper was suspended in extraction buffer for 1 h with ultrasonication. Drugs were then extracted from the buffer by solid-phase extraction using Clean Screen((R)) columns and analyzed by liquid chromatography-tandem mass spectrometry. Method validation showed that all calibration curves were linear over the concentration range 5-200 ng/spot with correlation coefficients of 0.994-0.999. Interday and intraday precisions at three concentrations (10, 50, and 100 ng/spot) were 1.6-18.3% and 2.8-14.7%, respectively. Limits of detection were 0.29-0.74 ng/spot, and lower limits of quantitation were 0.99-2.46 ng/spot. Recoveries of all analytes were in the range 81-106%. DBS were stored in duplicate at room temperature, 4 degrees C, and -20 degrees C for up to one month. Degradation of the drugs in DBS at all storage conditions was less than for the corresponding liquid blood samples stored under similar conditions and more than 80% of each analyte could be recovered from the samples.
Xu, Guifen; Chen, Jiyun S; Phadnis, Ruta; Huang, Tom; Uyeda, Craig; Soto, Marcus; Stouch, Brian; Wells, Mary C; James, Christopher A; Carlson, Timothy J
2012-08-01
Dried blood spot (DBS) sampling in combination with LC-MS/MS has been used increasingly in drug discovery for quantitative analysis to support pharmacokinetic (PK) studies. In this study, we assessed the effect of blood-to-plasma (B:P) partitioning on the bioanalytical performance and PK data acquired by DBS for a compound AMG-1 with species and concentration-dependent B:P ratio. B:P partitioning did not adversely affect bioanalytical performance of DBS for AMG-1. For rat, (B:P ratio of 0.63), PK profiles from DBS and plasma methods were comparable. For dog, concentration-dependence of B:P ratio was observed both in vivo and in vitro. Additional studies demonstrated concentration-dependence of the compound's unbound fraction in plasma, which may contribute to the concentration-dependence of the B:P ratio. DBS is a promising sampling technique for preclinical pharmacokinetic studies. For compounds with high B:P ratio, caution needs to be applied for data comparison and interpretation between matrices.
Veenhof, Herman; Koster, Remco A; Alffenaar, Jan-Willem C; Berger, Stefan P; Bakker, Stephan J L; Touw, Daan J
2017-07-01
Monitoring of creatinine and immunosuppressive drug concentrations, such as tacrolimus (TaC) and cyclosporin A (CsA), is important in the outpatient follow-up of kidney transplant recipients. Monitoring by dried blood spot (DBS) provides patients the opportunity to sample a drop of blood from a fingerprick at home, which can be sent to the laboratory by mail. We performed a clinical validation in which we compared measurements from whole-blood samples obtained by venapuncture with measurements from DBS samples simultaneously obtained by fingerprick. After exclusion of 10 DBS for poor quality, and 2 for other reasons, 199, 104, and 58 samples from a total of 172 patients were available for validation of creatinine, TaC and CsA, respectively. Validation was performed by means of Passing & Bablok regression, and bias was assessed by Bland-Altman analysis. For creatinine, we found y = 0.73x - 1.55 (95% confidence interval [95% CI] slope, 0.71-0.76), giving the conversion formula: (creatinine plasma concentration in μmol/L) = (creatinine concentration in DBS in μmol/L)/0.73, with a nonclinically relevant bias of -2.1 μmol/L (95% CI, -3.7 to -0.5 μmol/L). For TaC, we found y = 1.00x - 0.23 (95% CI slope, 0.91-1.08), with a nonclinically relevant bias of -0.28 μg/L (95% CI, -0.45 to -0.12 μg/L). For CsA, we found y = 0.99x - 1.86 (95% CI slope, 0.91-1.08) and no significant bias. Therefore, for neither TaC nor CsA, a conversion formula is required. DBS sampling for the simultaneous analysis of immunosuppressants and creatinine can replace conventional venous sampling in daily routine.
Dried Blood Spots - Preparing and Processing for Use in Immunoassays and in Molecular Techniques
Grüner, Nico; Stambouli, Oumaima; Ross, R. Stefan
2015-01-01
The idea of collecting blood on a paper card and subsequently using the dried blood spots (DBS) for diagnostic purposes originated a century ago. Since then, DBS testing for decades has remained predominantly focused on the diagnosis of infectious diseases especially in resource-limited settings or the systematic screening of newborns for inherited metabolic disorders and only recently have a variety of new and innovative DBS applications begun to emerge. For many years, pre-analytical variables were only inappropriately considered in the field of DBS testing and even today, with the exception of newborn screening, the entire pre-analytical phase, which comprises the preparation and processing of DBS for their final analysis has not been standardized. Given this background, a comprehensive step-by-step protocol, which covers al the essential phases, is proposed, i.e., collection of blood; preparation of blood spots; drying of blood spots; storage and transportation of DBS; elution of DBS, and finally analyses of DBS eluates. The effectiveness of this protocol was first evaluated with 1,762 coupled serum/DBS pairs for detecting markers of hepatitis B virus, hepatitis C virus, and human immunodeficiency virus infections on an automated analytical platform. In a second step, the protocol was utilized during a pilot study, which was conducted on active drug users in the German cities of Berlin and Essen. PMID:25867233
Geneva cocktail for cytochrome p450 and P-glycoprotein activity assessment using dried blood spots.
Bosilkovska, M; Samer, C F; Déglon, J; Rebsamen, M; Staub, C; Dayer, P; Walder, B; Desmeules, J A; Daali, Y
2014-09-01
The suitability of the capillary dried blood spot (DBS) sampling method was assessed for simultaneous phenotyping of cytochrome P450 (CYP) enzymes and P-glycoprotein (P-gp) using a cocktail approach. Ten volunteers received an oral cocktail capsule containing low doses of the probes bupropion (CYP2B6), flurbiprofen (CYP2C9), omeprazole (CYP2C19), dextromethorphan (CYP2D6), midazolam (CYP3A), and fexofenadine (P-gp) with coffee/Coke (CYP1A2) on four occasions. They received the cocktail alone (session 1), and with the CYP inhibitors fluvoxamine and voriconazole (session 2) and quinidine (session 3). In session 4, subjects received the cocktail after a 7-day pretreatment with the inducer rifampicin. The concentrations of probes/metabolites were determined in DBS and plasma using a single liquid chromatography-tandem mass spectrometry method. The pharmacokinetic profiles of the drugs were comparable in DBS and plasma. Important modulation of CYP and P-gp activities was observed in the presence of inhibitors and the inducer. Minimally invasive one- and three-point (at 2, 3, and 6 h) DBS-sampling methods were found to reliably reflect CYP and P-gp activities at each session.
Geneva Cocktail for Cytochrome P450 and P-Glycoprotein Activity Assessment Using Dried Blood Spots
Bosilkovska, M; Samer, C F; Déglon, J; Rebsamen, M; Staub, C; Dayer, P; Walder, B; Desmeules, J A; Daali, Y
2014-01-01
The suitability of the capillary dried blood spot (DBS) sampling method was assessed for simultaneous phenotyping of cytochrome P450 (CYP) enzymes and P-glycoprotein (P-gp) using a cocktail approach. Ten volunteers received an oral cocktail capsule containing low doses of the probes bupropion (CYP2B6), flurbiprofen (CYP2C9), omeprazole (CYP2C19), dextromethorphan (CYP2D6), midazolam (CYP3A), and fexofenadine (P-gp) with coffee/Coke (CYP1A2) on four occasions. They received the cocktail alone (session 1), and with the CYP inhibitors fluvoxamine and voriconazole (session 2) and quinidine (session 3). In session 4, subjects received the cocktail after a 7-day pretreatment with the inducer rifampicin. The concentrations of probes/metabolites were determined in DBS and plasma using a single liquid chromatography–tandem mass spectrometry method. The pharmacokinetic profiles of the drugs were comparable in DBS and plasma. Important modulation of CYP and P-gp activities was observed in the presence of inhibitors and the inducer. Minimally invasive one- and three-point (at 2, 3, and 6 h) DBS-sampling methods were found to reliably reflect CYP and P-gp activities at each session. PMID:24722393
Suyagh, Maysa Faisal; Iheagwaram, Godwill; Kole, Prashant Laxman; Millership, Jeff; Collier, Paul; Halliday, Henry; McElnay, James C
2010-05-01
A selective and sensitive high-performance liquid chromatography method with UV detection for the determination of metronidazole in dried blood spots (DBS) has been developed and validated. DBS samples [spiked or patient samples] were prepared by applying blood (30 microL) to Guthrie cards. Discs (6 mm diameter) were punched from the cards and extracted using water containing the internal standard, tinidazole. The extracted sample was chromatographed without further treatment using a reversed phase system involving a Symmetry(R) C18 (5 microm, 3.9 x 150 mm) preceded by a Symmetry(R) guard column of matching chemistry and a detection wavelength of 317 nm. The mobile phase comprised acetonitrile/0.01 M phosphate solution (KH(2)PO(4)), pH 4.7, 15:85, v/v, with a flow rate of 1 mL/min. The calibration was linear over the range 2.5-50 mg/mL. The limits of detection and quantification were 0.6 and 1.8 microg/mL, respectively. The method has been applied to the determination of 203 DBS samples from neonatal patients for a phamacokinetic/pharmacodynamic study.
Dried Blood Spots for qPCR Diagnosis of Acute Bartonella bacilliformis Infection
Smit, Pieter W.; Peeling, Rosanna W.; Garcia, Patricia J.; Torres, Lorena L.; Pérez-Lu, José E.; Moore, David; Mabey, David
2013-01-01
Bartonella bacilliformis is the etiological agent of a life-threatening illness. Thin blood smear is the most common diagnostic method for acute infection in endemic areas of Peru but remains of limited value because of low sensitivity. The aim of this study was to adapt a B. bacilliformis-specific real-time polymerase chain reaction (PCR) assay for use with dried blood spots (DBS) as a sampling method and assess its performance and use for the diagnosis and surveillance of acute Bartonella infection. Only two of 65 children (3%) that participated in this study had positive blood smears for B. bacilliformis, whereas 16 (including these two) were positive by PCR performed on DBS samples (24.6%). The use of DBS in combination with B. bacilliformis-specific PCR could be a useful tool for public health in identifying and monitoring outbreaks of infection and designing control programs to reduce the burden of this life-threatening illness. PMID:24043691
Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana
2015-05-10
In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.
Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing.
Murphy, Sean C; Daza, Glenda; Chang, Ming; Coombs, Robert
2012-12-01
Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.
Serrano, Laetitia; Muwonga, Jeremie; Kabuayi, Jean Pierre; Kambale, Alain; Mutaka, Fidèle; Fujiwara, Paula I.; Decosas, Josef; Peeters, Martine; Delaporte, Eric
2016-01-01
Background: As part of its policy to shift monitoring of antiretroviral therapy (ART) to primary health care (PHC) workers, the Ministry of Health of the Democratic Republic of Congo (DRC) tested the feasibility of using dried blood spots (DBS) for viral load (VL) quantification and genotypic drug resistance testing in off-site high-throughput laboratories. Methods: DBS samples from adults on ART were collected in 13 decentralized PHC facilities in the Nord-Kivu province and shipped during program quarterly supervision to a reference laboratory 2000 km away, where VL was quantified with a commercial assay (m2000rt, Abbott). A second DBS was sent to a World Health Organization (WHO)-accredited laboratory for repeat VL quantification on a subset of samples with a generic assay (Biocentric) and genotypic drug resistance testing when VL >1000 copies per milliliter. Findings: Constraints arose because of an interruption in national laboratory funding rather than to technical or logistic problems. All samples were assessed by both VL assays to allow ART adjustment. Median DBS turnaround time was 37 days (interquartile range: 9–59). Assays performed unequally with DBS, impacting clinical decisions, quality assurance, and overall cost-effectiveness. Based on m2000rt or generic assay, 31.3% of patients were on virological failure (VF) and 14.8% presented resistance mutations versus 50.3% and 15.4%, respectively. Conclusion: This study confirms that current technologies involving DBS make virological monitoring of ART possible at PHC level, including in challenging environments, provided organizational issues are addressed. Adequate core funding of HIV laboratories and adapted choice of VL assays require urgent attention to control resistance to ART as coverage expands. PMID:26413848
Mess, Jean-Nicholas; Taillon, Marie-Pierre; Côté, Cynthia; Garofolo, Fabio
2012-12-01
Thiorphan, the active metabolite of racecadotril, can undergo oxidation in biological matrices such as blood and plasma. In bioanalysis, a general approach for the stabilization of such a molecule is to derivatize the thiol group to a more stable thioether, often requiring complex handling procedures at the clinical site. In this research, the concept of dried blood spot (DBS) on-card derivatization was evaluated to stabilize thiorphan. DBS cards were in-house pre-treated with 2-bromo-3'-methoxyacetophenone and left to dry prior to blood spotting. Thiorphan was shown to be effectively derivatized to thiorphan-methoxyacetophenone once applied on the in-house pre-treated cards. Thiorphan-methoxyacetophenone was extracted by soaking a 6 mm DBS punch in methanol containing the internal standard (thiorphan-methoxyacetophenone-D₅). Chromatographic separation was achieved on a Waters XBridge C₁₈ column with a gradient elution of 5 mM NH₄HCO₃ and methanol in 2.5 min and detection by ESI(+)/MS/MS. A linear (weighted 1/x²) relationship was obtained over a concentration range of 5.00-600.00 ng/mL. The assay met regulatory guidelines acceptance criteria for sensitivity, selectivity, precision and accuracy, matrix effect, recovery, dilution integrity and multiple stability evaluations. The DBS on-card derivatization has shown to be an easy and reliable alternative form of sample collection for the quantification of thiorphan. Copyright © 2012 John Wiley & Sons, Ltd.
Cheung, Chi Yuen; van der Heijden, Jaques; Hoogtanders, Karin; Christiaans, Maarten; Liu, Yan Lun; Chan, Yiu Han; Choi, Koon Shing; van de Plas, Afke; Shek, Chi Chung; Chau, Ka Foon; Li, Chun Sang; van Hooff, Johannes; Stolk, Leo
2008-02-01
Dried blood spot (DBS) sampling and high-performance liquid chromatography tandem-mass spectrometry have been developed in monitoring tacrolimus levels. Our center favors the use of limited sampling strategy and abbreviated formula to estimate the area under concentration-time curve (AUC(0-12)). However, it is inconvenient for patients because they have to wait in the center for blood sampling. We investigated the application of DBS method in tacrolimus level monitoring using limited sampling strategy and abbreviated AUC estimation approach. Duplicate venous samples were obtained at each time point (C(0), C(2), and C(4)). To determine the stability of blood samples, one venous sample was sent to our laboratory immediately. The other duplicate venous samples, together with simultaneous fingerprick blood samples, were sent to the University of Maastricht in the Netherlands. Thirty six patients were recruited and 108 sets of blood samples were collected. There was a highly significant relationship between AUC(0-12), estimated from venous blood samples, and fingerprick blood samples (r(2) = 0.96, P < 0.0001). Moreover, there was an excellent correlation between whole blood venous tacrolimus levels in the two centers (r(2) = 0.97; P < 0.0001). The blood samples were stable after long-distance transport. DBS sampling can be used in centers using limited sampling and abbreviated AUC(0-12) strategy as drug monitoring.
Hoeller, Ulrich; Baur, Manuela; Roos, Franz F; Brennan, Lorraine; Daniel, Hannelore; Fallaize, Rosalind; Forster, Hannah; Gibney, Eileen R; Gibney, Mike; Godlewska, Magdalena; Hartwig, Kai; Kolossa, Silvia; Lambrinou, Christina P; Livingstone, Katherine M; Lovegrove, Julie A; Macready, Anna L; Manios, Yannis; Marsaux, Cyril F M; Martinez, J Alfredo; Celis-Morales, Carlos; Moschonis, George; Navas-Carretero, Santiago; O'Donovan, Clare B; San-Cristobal, Rodrigo; Saris, Wim H M; Surwiłło, Agnieszka; Traczyk, Iwona; Tsirigoti, Lydia; Walsh, Marianne C; Woolhead, Clara; Mathers, John C; Weber, Peter
2016-01-28
An efficient and robust method to measure vitamin D (25-hydroxy vitamin D3 (25(OH)D3) and 25-hydroxy vitamin D2 in dried blood spots (DBS) has been developed and applied in the pan-European multi-centre, internet-based, personalised nutrition intervention study Food4Me. The method includes calibration with blood containing endogenous 25(OH)D3, spotted as DBS and corrected for haematocrit content. The methodology was validated following international standards. The performance characteristics did not reach those of the current gold standard liquid chromatography-MS/MS in plasma for all parameters, but were found to be very suitable for status-level determination under field conditions. DBS sample quality was very high, and 3778 measurements of 25(OH)D3 were obtained from 1465 participants. The study centre and the season within the study centre were very good predictors of 25(OH)D3 levels (P<0·001 for each case). Seasonal effects were modelled by fitting a sine function with a minimum 25(OH)D3 level on 20 January and a maximum on 21 July. The seasonal amplitude varied from centre to centre. The largest difference between winter and summer levels was found in Germany and the smallest in Poland. The model was cross-validated to determine the consistency of the predictions and the performance of the DBS method. The Pearson's correlation between the measured values and the predicted values was r 0·65, and the sd of their differences was 21·2 nmol/l. This includes the analytical variation and the biological variation within subjects. Overall, DBS obtained by unsupervised sampling of the participants at home was a viable methodology for obtaining vitamin D status information in a large nutritional study.
Ma, Wanli; Kannan, Kurunthachalam; Wu, Qian; Bell, Erin M; Druschel, Charlotte M; Caggana, Michele; Aldous, Kenneth M
2013-05-01
Dried blood spots (DBS), collected as part of the newborn screening program (NSP) in the USA, is a valuable resource for studies on environmental chemical exposures and associated health outcomes in newborns. Nevertheless, determination of concentrations of environmental chemicals in DBS requires assays with great sensitivity, as the typical volume of blood available on a DBS with 16-mm diameter disc is approximately 50 μL. In this study, we developed a liquid-liquid extraction and high-performance liquid chromatography/tandem mass spectrometry method for the detection of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and bisphenol A (BPA) in DBS. The method was validated for accuracy, precision, and sensitivity, by spiking of target chemicals at different levels on Whatman 903 filter cards, which is used in the collection of DBS by the NSP. Contamination arising from collection, storage, and handling of DBS is an important issue to be considered in the analysis of trace levels of environmental chemicals in DBS. For the evaluation of the magnitude of background contamination, field blanks were prepared from unspotted portions of DBS filter cards collected by the NSP. The method was applied for the measurement of PFOS, PFOA, and BPA in 192 DBS specimens provided by NSP of New York State. PFOS and PFOA were detected in 100 % of the specimens analyzed. The concentrations of PFOS and PFOA measured in DBS were similar to those reported earlier in the whole blood samples of newborns. BPA was also found in 86 % of the specimens at concentrations ranging from 0.2 to 36 ng/mL (excluding two outliers). Further studies are needed to evaluate the sources of BPA exposures and health outcomes in newborns.
Validation and Application of a Dried Blood Spot Ceftriaxone Assay
Page-Sharp, Madhu; Nunn, Troy; Salman, Sam; Moore, Brioni R.; Batty, Kevin T.; Davis, Timothy M. E.
2015-01-01
Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic/pharmacodynamic (PK/PD) studies in situations where venous blood sampling is logistically and/or ethically problematic. In this study, we aimed to develop, validate, and apply a DBS ceftriaxone assay. A liquid chromatography-tandem mass spectroscopy (LC-MS/MS) DBS ceftriaxone assay was assessed for matrix effects, process efficiency, recovery, variability, and limits of quantification (LOQ) and detection (LOD). The effects of hematocrit, protein binding, red cell partitioning, and chad positioning were evaluated, and thermal stability was assessed. Plasma, DBS, and cell pellet ceftriaxone concentrations in 10 healthy adults were compared, and plasma concentration-time profiles of DBS and plasma ceftriaxone were incorporated into population PK models. The LOQ and LOD for ceftriaxone in DBS were 0.14 mg/liter and 0.05 mg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations (r > 0.95, P < 0.0001), and Bland-Altman plots showed no significant bias. The final population PK estimates of clearance, volume of distribution, and time above threshold MICs for measured and DBS-predicted plasma concentrations were similar. At 35°C, 21°C, 4°C, −20°C, and −80°C, ceftriaxone retained >95% initial concentrations in DBS for 14 h, 35 h, 30 days, 21 weeks, and >11 months, respectively. The present DBS ceftriaxone assay is robust and can be used as a surrogate for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including in studies of young children and of those in remote or resource-poor settings. PMID:26438505
Laser Cutting Eliminates Nucleic Acid Cross-Contamination in Dried-Blood-Spot Processing
Daza, Glenda; Chang, Ming; Coombs, Robert
2012-01-01
Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing. PMID:23052309
Dried blood spot analysis of creatinine with LC-MS/MS in addition to immunosuppressants analysis.
Koster, Remco A; Greijdanus, Ben; Alffenaar, Jan-Willem C; Touw, Daan J
2015-02-01
In order to monitor creatinine levels or to adjust the dosage of renally excreted or nephrotoxic drugs, the analysis of creatinine in dried blood spots (DBS) could be a useful addition to DBS analysis. We developed a LC-MS/MS method for the analysis of creatinine in the same DBS extract that was used for the analysis of tacrolimus, sirolimus, everolimus, and cyclosporine A in transplant patients with the use of Whatman FTA DMPK-C cards. The method was validated using three different strategies: a seven-point calibration curve using the intercept of the calibration to correct for the natural presence of creatinine in reference samples, a one-point calibration curve at an extremely high concentration in order to diminish the contribution of the natural presence of creatinine, and the use of creatinine-[(2)H3] with an eight-point calibration curve. The validated range for creatinine was 120 to 480 μmol/L (seven-point calibration curve), 116 to 7000 μmol/L (1-point calibration curve), and 1.00 to 400.0 μmol/L for creatinine-[(2)H3] (eight-point calibration curve). The precision and accuracy results for all three validations showed a maximum CV of 14.0% and a maximum bias of -5.9%. Creatinine in DBS was found stable at ambient temperature and 32 °C for 1 week and at -20 °C for 29 weeks. Good correlations were observed between patient DBS samples and routine enzymatic plasma analysis and showed the capability of the DBS method to be used as an alternative for creatinine plasma measurement.
2014-01-01
Background Levels of haemoglobin A1c (HbA1c) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource-poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods We conducted a systematic review and meta-analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases. PMID:25045323
Luckwell, Jacquelynn; Denniff, Philip; Capper, Stephen; Michael, Paul; Spooner, Neil; Mallender, Philip; Johnson, Barry; Clegg, Sarah; Green, Mark; Ahmad, Sheelan; Woodford, Lynsey
2013-11-01
To ensure that PK data generated from DBS samples are of the highest quality, it is important that the paper substrate is uniform and does not unduly contribute to variability. This study investigated any within and between lot variations for four cellulose paper types: Whatman™ FTA(®) DMPK-A, -B and -C, and 903(®) (GE Healthcare, Buckinghamshire, UK). The substrates were tested to demonstrate manufacturing reproducibility (thickness, weight, chemical coating concentration) and its effect on the size of the DBS produced, and the quantitative data derived from the bioanalysis of human DBS samples containing six compounds of varying physicochemical properties. Within and between lot variations in paper thickness, mass and chemical coating concentration were within acceptable manufacturing limits. No variation in the spot size or bioanalytical data was observed. Bioanalytical results obtained for DBS samples containing a number of analytes spanning a range of chemical space are not affected by the lot used or by the location within a lot.
The use of mass spectrometry to analyze dried blood spots.
Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard
2016-01-01
Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to sample preparation and will consider off-line and on-line extractions; in particular, instrumental designs that have been developed so far for DBS extraction will be detailed. Flow injection analysis and applications will be discussed in section IV. The application of surface analysis mass spectrometry (DESI, paper spray, DART, APTDCI, MALDI, LDTD-APCI, and ICP) to DBS is described in section V, while applications based on separation techniques (e.g., liquid or gas chromatography) are presented in section VI. To conclude this review, the current status of DBS analysis is summarized, and future perspectives are provided. © 2014 Wiley Periodicals, Inc.
Zainabadi, Kayvan; Adams, Matthew; Han, Zay Yar; Lwin, Hnin Wai; Han, Kay Thwe; Ouattara, Amed; Thura, Si; Plowe, Christopher V; Nyunt, Myaing M
2017-09-18
Greater Mekong Subregion countries are committed to eliminating Plasmodium falciparum malaria by 2025. Current elimination interventions target infections at parasite densities that can be detected by standard microscopy or rapid diagnostic tests (RDTs). More sensitive detection methods have been developed to detect lower density "asymptomatic" infections that may represent an important transmission reservoir. These ultrasensitive polymerase chain reaction (usPCR) tests have been used to identify target populations for mass drug administration (MDA). To date, malaria usPCR tests have used either venous or capillary blood sampling, which entails complex sample collection, processing and shipping requirements. An ultrasensitive method performed on standard dried blood spots (DBS) would greatly facilitate the molecular surveillance studies needed for targeting elimination interventions. A highly sensitive method for detecting Plasmodium falciparum and P. vivax 18S ribosomal RNA from DBS was developed by empirically optimizing nucleic acid extraction conditions. The limit of detection (LoD) was determined using spiked DBS samples that were dried and stored under simulated field conditions. Further, to assess its utility for routine molecular surveillance, two cross-sectional surveys were performed in Myanmar during the wet and dry seasons. The lower LoD of the DBS-based ultrasensitive assay was 20 parasites/mL for DBS collected on Whatman 3MM filter paper and 23 parasites/mL for Whatman 903 Protein Saver cards-equivalent to 1 parasite per 50 µL DBS. This is about 5000-fold more sensitive than standard RDTs and similar to the LoD of ≤16-22 parasites/mL reported for other ultrasensitive methods based on whole blood. In two cross-sectional surveys in Myanmar, nearly identical prevalence estimates were obtained from contemporaneous DBS samples and capillary blood samples collected during the wet and dry season. The DBS-based ultrasensitive method described in this study shows equal sensitivity as previously described methods based on whole blood, both in its limit of detection and prevalence estimates in two field surveys. The reduced cost and complexity of this method will allow for the scale-up of surveillance studies to target MDA and other malaria elimination interventions, and help lead to a better understanding of the epidemiology of low-density malaria infections.
An Overview of the Clinical Use of Filter Paper in the Diagnosis of Tropical Diseases
Smit, Pieter W.; Elliott, Ivo; Peeling, Rosanna W.; Mabey, David; Newton, Paul N.
2014-01-01
Tropical infectious diseases diagnosis and surveillance are often hampered by difficulties of sample collection and transportation. Filter paper potentially provides a useful medium to help overcome such problems. We reviewed the literature on the use of filter paper, focusing on the evaluation of nucleic acid and serological assays for diagnosis of infectious diseases using dried blood spots (DBS) compared with recognized gold standards. We reviewed 296 eligible studies and included 101 studies evaluating DBS and 192 studies on other aspects of filter paper use. We also discuss the use of filter paper with other body fluids and for tropical veterinary medicine. In general, DBS perform with sensitivities and specificities similar or only slightly inferior to gold standard sample types. However, important problems were revealed with the uncritical use of DBS, inappropriate statistical analysis, and lack of standardized methodology. DBS have great potential to empower healthcare workers by making laboratory-based diagnostic tests more readily accessible, but additional and more rigorous research is needed. PMID:24366501
A Simple Method to Quantitate IP-10 in Dried Blood and Plasma Spots
Aabye, Martine G.; Eugen-Olsen, Jesper; Werlinrud, Anne Marie; Holm, Line Lindebo; Tuuminen, Tamara; Ravn, Pernille; Ruhwald, Morten
2012-01-01
Background Antigen specific release of IP-10 is an established marker for infection with M.tuberculosis. Compared to IFN-γ, IP-10 is released in 100-fold higher concentrations enabling the development of novel assays for detection. Dried blood spots are a convenient sample for high throughput newborn screening. Aim To develop a robust and sensitive ELISA-based assay for IP-10 detection in plasma, dried blood spots (DBS) and dried plasma spots (DPS); to validate the ELISA in clinically relevant samples; and to assess the performance of the assay for detection of Cytomegalovirus (CMV) and M.tuberculosis specific immune responses. Method We raised mice and rat monoclonal antibodies against human IP-10 and developed an ELISA. The assay was validated and applied to the detection of CMV and M.tuberculosis specific responses in 18 patients with immune reactivity towards M.tuberculosis and 32 healthy controls of which 22 had immune reactivity towards CMV and none towards M.tuberculosis. We compared the performance of this new assay to IFN-γ. Results The ELISA was reliable for IP-10 detection in both plasma and filter paper samples. The linear range of the ELISA was 2.5–600 pg/ml. IFN-γ was not readily detectable in DPS samples. IP-10 was stabile in filter paper samples for at least 4 weeks at 37°C. The correlation between IP-10 detected in plasma, DPS and DBS samples was excellent (r2>0.97). Conclusions This newly developed assay is reliable for IP-10 quantification in plasma, DBS and DPS samples from antigen stimulated and non-stimulated whole blood. The filter paper assays enable easy sample acquisition and transport at ambient temperature e.g. via the postal system. The system can potentially simplify diagnostic assays for M.tuberculosis and CMV infection. PMID:22761744
de Las Hazas, María Carmen López; Motilva, Maria José; Piñol, Carme; Macià, Alba
2016-10-01
In this study, a fast and simple blood sampling and sample pre-treatment method based on the use of the dried blood spot (DBS) cards and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for the quantification of olive oil phenolic metabolites in human blood was developed and validated. After validation, the method was applied to determine hydroxytyrosol metabolites in human blood samples after the acute intake of an olive oil phenolic extract. Using the FTA DMPK-A DBS card under optimum conditions, with 20µL as the blood solution volume, 100µL of methanol/Milli-Q water (50/50, v/v) as the extraction solvent and 7 disks punched out from the card, the main hydroxytyrosol metabolites (hydroxytyrosol-3-O-sulphate and hydroxytyrosol acetate sulphate) were identified and quantified. The developed methodology allowed detecting and quantifying the generated metabolites at low μM levels. The proposed method is a significant improvement over existing methods to determine phenolic metabolites circulating in blood and plasma samples, thus making blood sampling possible with the volunteer pricking their own finger, and the subsequent storage of the blood in the DBS cards prior to chromatographic analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Markwalter, Christine F.; Gibson, Lauren E.; Mudenda, Lwiindi; Kimmel, Danielle W.; Mbambara, Saidon; Thuma, Philip E.; Wright, David W.
2018-01-01
Abstract. A rapid, on-bead enzyme-linked immunosorbent assay for Plasmodium lactate dehydrogenase (pLDH) and Plasmodium falciparum histidine-rich protein 2 (HRP2) was adapted for use with dried blood spot (DBS) samples. This assay detected both biomarkers from a single DBS sample with only 45 minutes of total incubation time and detection limits of 600 ± 500 pM (pLDH) and 69 ± 30 pM (HRP2), corresponding to 150 and 24 parasites/μL, respectively. This sensitive and reproducible on-bead detection method was used to quantify pLDH and HRP2 in patient DBS samples from rural Zambia collected at multiple time points after treatment. Biomarker clearance patterns relative to parasite clearance were determined; pLDH clearance followed closely with parasite clearance, whereas most patients maintained detectable levels of HRP2 for 35–52 days after treatment. Furthermore, weak-to-moderate correlations between biomarker concentration and parasite densities were found for both biomarkers. This work demonstrates the utility of the developed assay for epidemiological study and surveillance of malaria. PMID:29557342
Kummer, Natalie; Ingels, Ann-Sofie; Wille, Sarah M R; Hanak, Catherine; Verbanck, Paul; Lambert, Willy E E; Samyn, Nele; Stove, Christophe P
2016-01-01
Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55% (RSD < 18%) and matrix effects compensated for by IS were between 77 and 125% (RSD < 10%). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13%). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86%). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption.
Cohen-Wolkowiez, Michael; Sampson, Mario; Bloom, Barry T.; Arrieta, Antonio; Wynn, James L.; Martz, Karen; Harper, Barrie; Kearns, Gregory L.; Capparelli, Edmund V.; Siegel, David; Benjamin, Daniel K.; Smith, P. Brian
2013-01-01
Background Limited pharmacokinetic (PK) data of metronidazole in premature infants has led to various dosing recommendations. Surrogate efficacy targets for metronidazole are ill-defined and therefore aimed to exceed minimum inhibitory concentration of organisms responsible for intra-abdominal infections. Methods We evaluated the PK of metronidazole using plasma and dried blood spot (DBS) samples from infants ≤32 weeks gestational age in an open-label, PK, multicenter (N=3) study using population PK modeling (NONMEM). Monte Carlo simulations (N=1000 virtual subjects) were used to evaluate the surrogate efficacy target. Metabolic ratios of parent and metabolite were calculated. Results Twenty-four premature infants (111 plasma and 51 DBS samples) were enrolled: median (range) gestational age at birth 25 (23–31) weeks, postnatal age 27 (1–82) days, postmenstrual age (PMA) 31 (24–39) weeks, and weight 740 (431–1466) g. Population clearance (CL, L/h/kg) was 0.038 × (PMA/30)2.45 and volume of distribution (L/kg) of 0.93. PK parameter estimates and precision were similar between plasma and DBS samples. Metabolic ratios correlated with CL. Conclusion Simulations suggested the majority of infants in the neonatal intensive care unit (>80%) would meet the surrogate efficacy target using PMA-based dosing. PMID:23587979
Singh, Gurmeet K S; Turner, Leo; Desai, Reena; Jimenez, Mark; Handelsman, David J
2014-07-01
Testosterone (T) and nandrolone (N) esters require deep im injections by medical personnel but these often deposit injectate into sc fat so that more convenient sc self-administration may be feasible. To investigate the feasibility and pharmacology of sc injection of N decanoate in healthy men using dried blood spot (DBS) for frequent blood sampling without clinic visits. Healthy male volunteers received 100 mg N decanoate by a single sc injection. Finger-prick capillary blood was spotted onto filter paper before injection daily at home for 21 d and stored at room temperature. Venous whole blood was also spotted onto filter paper before and weekly for 3 wk after injection. DBS were extracted for assay of N and T by liquid chromatography tandem mass spectrometry in a single batch with serum concentrations estimated with adjustment for capillary blood sample volume and hematocrit to define peak (N) or nadir (T) time and concentration from individual daily measurements. Daily serum N peaked 2.50 ± 0.25 (SEM) ng/mL at a median (range) of 6 (4-13) days causing a reduction in serum T from 3.50 ± 0.57 ng/mL at baseline to a nadir of 0.38 ± 0.13 (SEM) ng/mL (89 ± 3% suppression) at a median (range) of 8 (5-16) days. Simultaneously sampled capillary, venous whole blood, and serum gave almost identical results for serum T and N. Finger-pricks and sc injections were well tolerated. This study demonstrates that A) DBS sampling with liquid chromatography mass spectrometry steroid analysis achieves frequent time sampling in the community without requiring clinic visits, venesection, or frozen serum storage, and B) androgen esters in an oil vehicle can be delivered effectively by sc injection, thus avoiding the need for medically supervised deep-im injections.
Inzaule, Seth; Yang, Chunfu; Kasembeli, Alex; Nafisa, Lillian; Okonji, Jully; Oyaro, Boaz; Lando, Richard; Mills, Lisa A.; Laserson, Kayla; Thomas, Timothy; Nkengasong, John
2013-01-01
HIV-1 drug resistance (HIVDR) assays are important tools in clinical management of HIV-infected patients on antiretroviral therapy (ART) and surveillance of drug-resistant variants at population levels. The high cost associated with commercial assays hinders their use in resource-limited settings. We adopted and validated a low-cost in-house assay using 68 matched plasma and dried blood spot (DBS) samples with a median viral load (VL) of 58,187 copies/ml, ranging from 253 to 3,264,850 against the commercial assay ViroSeq. Results indicated that the in-house assay not only had a higher plasma genotyping rate than did ViroSeq (94% versus 78%) but also was able to genotype 89.5% (51/57) of the matched DBS samples with VLs of ≥1,000 copies/ml. The sensitivity in detecting DR mutations by the in-house assay was 98.29% (95% confidence interval [CI], 97.86 to 98.72) on plasma and 96.54 (95% CI, 95.93 to 97.15) on DBS, and the specificity was 99.97% (95% CI, 99.91 to 100.00) for both sample types compared to ViroSeq. The minor DR mutation differences detected by the in-house assay against ViroSeq did not result in clinical significance. In addition, cost analysis showed that the in-house assay could reduce the genotyping cost by about 60% for both plasma and DBS compared to ViroSeq. This field condition evaluation highlights the potential utility of a cost-effective, subtype-independent, in-house genotyping assay using both plasma and DBS specimens for HIVDR clinical monitoring and population-based surveillance in resource-limited settings. PMID:23224100
Nelson, Julie A E; Hawkins, J Tyler; Schanz, Maria; Mollan, Katie; Miller, Melissa B; Schmitz, John L; Fiscus, Susan A
2014-08-01
The current gold standard for infant diagnosis of HIV-1 is the Roche Amplicor Qualitative DNA assay, but it is being phased out. Compare the Abbott qualitative assay and the Gen-Probe Aptima assay to the gold standard Roche DNA assay using dried blood spots (DBS). The Gen-Probe Aptima and Abbott qualitative HIV-1 assays were compared to the Roche DNA assay for early infant diagnosis. Specificity and sensitivity were determined for the three assays using DBS from 50 HIV-exposed uninfected infants and 269 HIV-1 infected adults from North Carolina, respectively. All of the negative and 151 of the positive DBS had valid results on the 3 different assays, and an additional 118 positive DBS had valid results on the Roche DNA and Aptima assays. All three assays were very specific. The Roche DNA assay was the most sensitive (96.7%) over a wide range of HIV PVL, including samples with PVL<400 copies/ml. Restricted to samples with PVL>400 copies/ml, the Gen-Probe Aptima assay had sensitivity (96.5%) comparable to the Roche DNA assay (98.8%). The Abbott Qualitative assay was the least sensitive and only had sensitivity above 95% among samples with PVL over 1000 copies/ml. The Abbott HIV-1 Qualitative assay was not as sensitive as the comparator assays, so it would not be a useful replacement assay, especially for infants taking antiretroviral prophylaxis. The Gen-Probe Aptima assay is an adequate replacement option for infant diagnosis using DBS. Copyright © 2014 Elsevier B.V. All rights reserved.
Baldo, Matías N; Angeli, Emmanuel; Gareis, Natalia C; Hunzicker, Gabriel A; Murguía, Marcelo C; Ortega, Hugo H; Hein, Gustavo J
2018-04-01
A relative bioavailability study (RBA) of two phenytoin (PHT) formulations was conducted in rabbits, in order to compare the results obtained from different matrices (plasma and blood from dried blood spot (DBS) sampling) and different experimental designs (classic and block). The method was developed by liquid chromatography tandem-mass spectrometry (LC-MS/MS) in plasma and blood samples. The different sample preparation techniques, plasma protein precipitation and DBS, were validated according to international requirements. The analytical method was validated with ranges 0.20-50.80 and 0.12-20.32 µg ml -1 , r > 0.999 for plasma and blood, respectively. Accuracy and precision were within acceptance criteria for bioanalytical assay validation (< 15 for bias and CV% and < 20 for limit of quantification (LOQ)). PHT showed long-term stability, both for plasma and blood, and under refrigerated and room temperature conditions. Haematocrit values were measured during the validation process and RBA study. Finally, the pharmacokinetic parameters (C max , T max and AUC 0-t ) obtained from the RBA study were tested. Results were highly comparable for matrices and experimental designs. A matrix correlation higher than 0.975 and a ratio of (PHT blood) = 1.158 (PHT plasma) were obtained. The results obtained herein show that the use of classic experimental design and DBS sampling for animal pharmacokinetic studies should be encouraged as they could help to prevent the use of a large number of animals and also animal euthanasia. Finally, the combination of DBS sampling with LC-MS/MS technology showed to be an excellent tool not only for therapeutic drug monitoring but also for RBA studies.
Iroh Tam, Pui-Ying; Hernandez-Alvarado, Nelmary; Schleiss, Mark R; Hassan-Hanga, Fatimah; Onuchukwu, Chuma; Umoru, Dominic; Obaro, Stephen K
2016-01-01
Nigeria has one of the highest burdens of pneumococcal disease in the world, but accurate surveillance is lacking. Molecular detection of infectious pathogens in dried blood spots (DBS) is an ideal method for surveillance of infections in resource-limited settings because of its low cost, minimal blood volumes involved, and ease of storage at ambient temperature. Our study aim was to evaluate a Streptococcus pneumoniae real-time polymerase chain reaction (rt-PCR) assay on DBS from febrile Nigerian children on Whatman 903 and FTA filter papers, compared to the gold standard of culture. Between September 2011 to May 2015, blood was collected from children 5 years of age or under who presented to six hospital study sites throughout northern and central Nigeria with febrile illness, and inoculated into blood culture bottles or spotted onto Whatman 903 or FTA filter paper. Culture and rt-PCR were performed on all samples. A total of 537 DBS specimens from 535 children were included in the study, of which 15 were culture-positive for S. pneumoniae. The rt-PCR assay detected S. pneumoniae in 12 DBS specimens (2.2%). One positive rt-PCR result was identified in a culture-negative specimen from a high-risk subject, and two positive rt-PCR results were negative on repeat testing. Six culture-confirmed cases of S. pneumoniae bacteremia were missed. Compared to culture, the overall sensitivities of Whatman 903 and FTA DBS for detection of S. pneumoniae were 57.1% (95% CI 18.4-90.1%) and 62.5% (95% CI 24.5-91.5%), respectively. Nonspecific amplification was noted in an additional 22 DBS (4.1%). Among these, six were positive for a non-S. pneumoniae pathogen on culture. Rt-PCR was able to detect S. pneumoniae from clinical DBS specimens, including from a culture-negative specimen. Our findings show promise of this approach as a surveillance diagnostic, but also raise important cautionary questions. Several DBS specimens were detected as S. pneumoniae by rt-PCR despite growth of a non-S. pneumoniae pathogen on culture. A precise definition of what constitutes a positive result is required to avoid falsely over-identifying specimens.
Knippenberg, Ben; Page-Sharp, Madhu; Clark, Ben; Dyer, John; Batty, Kevin T.; Davis, Timothy M. E.
2016-01-01
Dried blood spot (DBS) antibiotic assays can facilitate pharmacokinetic (PK)/pharmacodynamic (PD) studies in situations where venous blood sampling is logistically difficult. We sought to develop, validate, and apply a DBS assay for rifampin (RIF), fusidic acid (FUS), and ciprofloxacin (CIP). These antibiotics are considered active against organisms in biofilms and are therefore commonly used for the treatment of infections associated with prosthetic implants. A liquid chromatography-mass spectroscopy DBS assay was developed and validated, including red cell partitioning and thermal stability for each drug and the rifampin metabolite desacetyl rifampin (Des-RIF). Plasma and DBS concentrations in 10 healthy adults were compared, and the concentration-time profiles were incorporated into population PK models. The limits of quantification for RIF, Des-RIF, CIP, and FUS in DBS were 15 μg/liter, 14 μg/liter, 25 μg/liter, and 153 μg/liter, respectively. Adjusting for hematocrit, red cell partitioning, and relative recovery, DBS-predicted plasma concentrations were comparable to measured plasma concentrations for each antibiotic (r > 0.95; P < 0.0001), and Bland-Altman plots showed no significant bias. The final population PK estimates of clearance, volume of distribution, and time above threshold MICs for measured and DBS-predicted plasma concentrations were comparable. These drugs were stable in DBSs for at least 10 days at room temperature and 1 month at 4°C. The present DBS antibiotic assays are robust and can be used as surrogates for plasma concentrations to provide valid PK and PK/PD data in a variety of clinical situations, including therapeutic drug monitoring or studies of implant infections. PMID:27270283
Jordan, Jeanne A; Ibe, Christine O; Moore, Miranda S; Host, Christel; Simon, Gary L
2012-05-01
In resource-limited settings (RLS) dried blood spots (DBS) are collected on infants and transported through provincial laboratories to a central facility where HIV-1 DNA PCR testing is performed using specialized equipment. Implementing a simpler approach not requiring such equipment or skilled personnel could allow the more numerous provincial laboratories to offer testing, improving turn-around-time to identify and treat infected infants sooner. Assess performances of a manual DNA extraction method and helicase-dependent amplification (HDA) assay for detecting HIV-1 DNA from DBS. 60 HIV-1 infected adults were enrolled, blood samples taken and DBS made. DBS extracts were assessed for DNA concentration and beta globin amplification using PCR and melt-curve analysis. These same extracts were then tested for HIV-1 DNA using HDA and compared to results generated by PCR and pyrosequencing. Finally, HDA limit of detection (LOD) studies were performed using DBS extracts prepared with known numbers of 8E5 cells. The manual extraction protocol consistently yielded high concentrations of amplifiable DNA from DBS. LOD assessment demonstrated HDA detected ∼470 copies/ml of HIV-1 DNA extracts in 4/4 replicates. No statistical difference was found using the McNemar's test when comparing HDA to PCR for detecting HIV-1 DNA from DBS. Using just a magnet, heat block and pipettes, the manual extraction protocol and HDA assay detected HIV-1 DNA from DBS at levels that would be useful for early infant diagnosis. Next steps will include assessing HDA for non-B HIV-1 subtypes recognition and comparison to Roche HIV-1 DNA v1.5 PCR assay. Copyright © 2012 Elsevier B.V. All rights reserved.
Chang, Joy; de Sousa, Amina; Sabatier, Jennifer; Assane, Mariamo; Zhang, Guoqing; Bila, Dulce; Vaz, Paula; Alfredo, Charity; Cossa, Loide; Bhatt, Nilesh; Koumans, Emilia H.; Yang, Chunfu; Rivadeneira, Emilia; Jani, Ilesh; Houston, James C.
2017-01-01
Quantitative plasma viral load (VL) at 1000 copies /mL was recommended as the threshold to confirm antiretroviral therapy (ART) failure by the World Health Organization (WHO). Because of ongoing challenges of using plasma for VL testing in resource-limited settings (RLS), especially for children, this study collected 717 DBS and paired plasma samples from children receiving ART ≥1 year in Mozambique and compared the performance of DBS using Abbott’s VL test with a paired plasma sample using Roche’s VL test. At a cut-off of 1000 copies/mL, sensitivity of DBS using Abbott DBS VL test was 79.9%, better than 71.0% and 63.9% at 3000 and 5000 copies/mL, respectively. Specificities were 97.6%, 98.8%, 99.3% at 1000, 3000, and 5000 copies/mL, respectively. The Kappa value at 1000 copies/mL, 0.80 (95% CI: 0.73, 0.87), was higher than 0.73 (95% CI: 0.66, 0.80) and 0.66 (95% CI: 0.59, 0.73) at 3000, 5000 copies/mL, respectively, also indicating better agreement. The mean difference between the DBS and plasma VL tests with 95% limits of agreement by Bland-Altman was 0.311 (-0.908, 1.530). Among 73 children with plasma VL between 1000 to 5000 copies/mL, the DBS results were undetectable in 53 at the 1000 copies/mL threshold. While one DBS sample in the Abbott DBS VL test may be an alternative method to confirm ART failure at 1000 copies/mL threshold when a plasma sample is not an option for treatment monitoring, because of sensitivity concerns between 1,000 and 5,000 copies/ml, two DBS samples may be preferred accompanied by careful patient monitoring and repeat testing. PMID:28704560
Homocysteine measurement in dried blood spot for neonatal detection of homocystinurias.
Alodaib, Ahmad N; Carpenter, Kevin; Wiley, Veronica; Wotton, Tiffany; Christodoulou, John; Wilcken, Bridget
2012-01-01
Expanded newborn screening (NBS) leads to an increased number of false positive results, causing parental anxiety, greater follow-up costs, and the need for further metabolic investigations. We developed and validated a second-tier approach for NBS of homocystinurias by measuring the total homocysteine (tHcy) on the initial dried blood spot (DBS) samples to reduce the need for further investigation, and investigated newborn DBS homocysteine values in patients with homocystinuria. Total DBS homocysteine was measured in normal newborns, and retrospectively in newborns with established disorders, using liquid chromatography tandem mass spectrometry (LC-MS/MS) with stable isotope-labelled internal standards for homocysteine. Analytes were separated using reverse phase chromatography with a total run time of 3 min. The method was linear over the range of 10-100 μmol/L of tHcy and showed excellent precision; intra-batch CV was 4% and inter-batch precision 6.5%. Comparison of 59 plasma values with DBS for tHcy taken at the same time showed excellent correlation, (r (2)>0.97). The reference range for current neonatal samples was 5.4-10.7 μmol/L (n=99), and for the stored neonatal samples (stored dry, sealed in plastic at room temperature for 10 years) was 1.7-5.5 μmol/L, (n=50), both being normally distributed. The clinical utility of this method was checked by retrospective analysis of stored NBS samples from patients with different forms of homocystinuria, including four different remethylating disorders. All had clear elevations of tHcy.
Wang, Chunyan; Zhu, Hongbin; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-02-01
The quantitative analysis of amino acids (AAs) in single dry blood spot (DBS) samples is an important issue for metabolic diseases as a second-tier test in newborn screening. An analytical method for quantifying underivatized AAs in DBS was developed by using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The sample preparation in this method is simple and ion-pairing agent is not used in the mobile phase that could avoid ion suppression, which happens in mass spectrometry and avoids damage to the column. Through chromatographic separation, some isomeric compounds could be identified and quantified, which cannot be solved through only appropriate multiple reactions monitoring transitions by MS/MS. The concentrations of the different AAs were determined using non-deuterated internal standard. All calibration curves showed excellent linearity within test ranges. For most of the amino acids the accuracy of extraction recovery was between 85.3 and 115 %, and the precision of relative standard deviation was <7.0 %. The 35 AAs could be identified in DBS specimens by the developed LC-MS/MS method in 17-19 min, and eventually 24 AAs in DBS were quantified. The results of the present study prove that this method as a second-tier test in newborn screening for metabolic diseases could be performed by the quantification of free AAs in DBS using the LC-MS/MS method. The assay has advantages of high sensitive, specific, and inexpensive merits because non-deuterated internal standard and acetic acid instead of ion-pairing agent in mobile phase are used in this protocol.
Canier, Lydie; Khim, Nimol; Kim, Saorin; Eam, Rotha; Khean, Chanra; Loch, Kaknika; Ken, Malen; Pannus, Pieter; Bosman, Philippe; Stassijns, Jorgen; Nackers, Fabienne; Alipon, SweetC; Char, Meng Chuor; Chea, Nguon; Etienne, William; De Smet, Martin; Kindermans, Jean-Marie; Ménard, Didier
2015-01-01
In the context of malaria elimination, novel strategies for detecting very low malaria parasite densities in asymptomatic individuals are needed. One of the major limitations of the malaria parasite detection methods is the volume of blood samples being analyzed. The objective of the study was to compare the diagnostic accuracy of a malaria polymerase chain reaction assay, from dried blood spots (DBS, 5 μL) and different volumes of venous blood (50 μL, 200 μL, and 1 mL). The limit of detection of the polymerase chain reaction assay, using calibrated Plasmodium falciparum blood dilutions, showed that venous blood samples (50 μL, 200 μL, 1 mL) combined with Qiagen extraction methods gave a similar threshold of 100 parasites/mL, ∼100-fold lower than 5 μL DBS/Instagene method. On a set of 521 field samples, collected in two different transmission areas in northern Cambodia, no significant difference in the proportion of parasite carriers, regardless of the methods used was found. The 5 μL DBS method missed 27% of the samples detected by the 1 mL venous blood method, but most of the missed parasites carriers were infected by Plasmodium vivax (84%). The remaining missed P. falciparum parasite carriers (N = 3) were only detected in high-transmission areas. PMID:25561570
Storage and use of residual dried blood spots from state newborn screening programs.
Olney, Richard S; Moore, Cynthia A; Ojodu, Jelili A; Lindegren, Mary Lou; Hannon, W Harry
2006-05-01
To provide current data for policy discussions and to assess future needs among newborn screening programs regarding the storage and use of residual dried blood spots (DBS) in the United States. An electronic questionnaire was administered to U.S. state health department laboratory directors in 2003. Responses were received from 49 of the 50 states. Approximately half of them stored residual DBS for more than 6 months, 57% did not have a written policy that determines how residual DBS can or cannot be used, and 16% informed parents that DBS might be retained. Residual DBS were used by 74% of respondents for evaluation of newborn screening tests, by 52% for clinical or forensic testing, and by 28% for epidemiologic studies. Use of DBS was reported more frequently by states with extended storage. When asked if they might participate in an anonymous multistate epidemiologic study by contributing unlinked DBS, 41% responded affirmatively. More states have used residual DBS for evaluating newborn screening tests than for epidemiologic studies. There is potential interest among states in using unlinked DBS for multistate studies and a need for written policies addressing all uses of residual DBS.
Sensitivity and specificity of dried blood spots for HIV-1 viral load quantification
Pannus, Pieter; Claus, Maarten; Gonzalez, Maria Mercedes Perez; Ford, Nathan; Fransen, Katrien
2016-01-01
Abstract The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS. Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined. A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL. All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1). The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens. PMID:27902602
Pannus, Pieter; Claus, Maarten; Gonzalez, Maria Mercedes Perez; Ford, Nathan; Fransen, Katrien
2016-11-01
The use of dried blood spots (DBS) instead of plasma as a specimen type for HIV-1 viral load (VL) testing facilitates the decentralization of specimen collection and can increase access to VL testing in resource-limited settings. The performance of DBS for VL testing is lower, however, when compared to the gold standard sample type plasma. In this diagnostic accuracy study, we evaluated 3 VL assays with DBS.Participants were recruited between August 2012 and April 2015. Both plasma and DBS specimens were prepared and tested for HIV-1 VL with the Roche CAP/CTM HIV-1 test v2.0, the Abbott RealTime HIV-1, and the bioMérieux NucliSENS EasyQ HIV-1 v2.0. Sensitivity and specificity to detect treatment failure at a threshold of 1000 cps/mL with DBS were determined.A total of 272 HIV-positive patients and 51 HIV-negative people were recruited in the study. The mean difference or bias between plasma and DBS VL was <0.5 log cps/mL with all 3 assays but >25% of the specimens differed by >0.5 log cps/mL.All 3 assays had comparable sensitivities around 80% and specificities around 90%. Upward misclassification rates were around 10%, but downward misclassification rates ranged from 20.3% to 23.6%. Differences in between assays were not statistically significant (P > 0.1).The 3 VL assays evaluated had suboptimal performance with DBS but still performed better than immunological or clinical monitoring. Even after the introduction of the much-anticipated point-of-care VL devices, it is expected that DBS will remain important as a complementary option for supporting access to VL monitoring, particularly in rural, resource-limited settings. Manufacturers should accelerate efforts to develop more reliable, sensitive and specific methods to test VL on DBS specimens.
Rafkin, Lisa E.; Matheson, Della; Steck, Andrea K.; Yu, Liping; Henderson, Courtney; Beam, Craig A.; Boulware, David C.
2015-01-01
Abstract Background: Islet autoantibody testing provides the basis for assessment of risk of progression to type 1 diabetes. We set out to determine the feasibility and acceptability of dried capillary blood spot–based screening to identify islet autoantibody–positive relatives potentially eligible for inclusion in prevention trials. Materials and Methods: Dried blood spot (DBS) and venous samples were collected from 229 relatives participating in the TrialNet Pathway to Prevention Study. Both samples were tested for glutamic acid decarboxylase, islet antigen 2, and zinc transporter 8 autoantibodies, and venous samples were additionally tested for insulin autoantibodies and islet cell antibodies. We defined multiple autoantibody positive as two or more autoantibodies in venous serum and DBS screen positive if one or more autoantibodies were detected. Participant questionnaires compared the sample collection methods. Results: Of 44 relatives who were multiple autoantibody positive in venous samples, 42 (95.5%) were DBS screen positive, and DBS accurately detected 145 of 147 autoantibody-negative relatives (98.6%). Capillary blood sampling was perceived as more painful than venous blood draw, but 60% of participants would prefer initial screening using home fingerstick with clinic visits only required if autoantibodies were found. Conclusions: Capillary blood sampling could facilitate screening for type 1 diabetes prevention studies. PMID:26375197
Quantitative assessment of anthrax vaccine immunogenicity using the dried blood spot matrix.
Schiffer, Jarad M; Maniatis, Panagiotis; Garza, Ilana; Steward-Clark, Evelene; Korman, Lawrence T; Pittman, Phillip R; Mei, Joanne V; Quinn, Conrad P
2013-03-01
The collection, processing and transportation to a testing laboratory of large numbers of clinical samples during an emergency response situation present significant cost and logistical issues. Blood and serum are common clinical samples for diagnosis of disease. Serum preparation requires significant on-site equipment and facilities for immediate processing and cold storage, and significant costs for cold-chain transport to testing facilities. The dried blood spot (DBS) matrix offers an alternative to serum for rapid and efficient sample collection with fewer on-site equipment requirements and considerably lower storage and transport costs. We have developed and validated assay methods for using DBS in the quantitative anti-protective antigen IgG enzyme-linked immunosorbent assay (ELISA), one of the primary assays for assessing immunogenicity of anthrax vaccine and for confirmatory diagnosis of Bacillus anthracis infection in humans. We have also developed and validated high-throughput data analysis software to facilitate data handling for large clinical trials and emergency response. Published by Elsevier Ltd.
Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen
2016-01-01
Background Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. Objectives This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Methods Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Results Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. Conclusions The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care. PMID:28879108
Govender, Kerusha; Parboosing, Raveen; Siyaca, Ntombizandile; Moodley, Pravikrishnen
2016-01-01
Poor quality dried blood spot (DBS) specimens are usually rejected by virology laboratories, affecting early infant diagnosis of HIV. The practice of combining two incompletely-filled DBS in one specimen preparation tube during pre-analytical specimen processing (i.e., the two-spot method) has been implemented to reduce the number of specimens being rejected for insufficient volume. This study analysed laboratory data to describe the quality of DBS specimens and the use of the two-spot method over a one-year period, then validated the two-spot method against the standard (one-spot) method. Data on HIV-1 PCR test requests submitted in 2014 to the Department of Virology at Inkosi Albert Luthuli Central Hospital in KwaZulu-Natal province, South Africa were analysed to describe reasons for specimen rejection, as well as results of the two-spot method. The accuracy, lower limit of detection and precision of the two-spot method were assessed. Of the 88 481 specimens received, 3.7% were rejected for pre-analytical problems. Of those, 48.9% were rejected as a result of insufficient specimen volume. Two health facilities had significantly more specimen rejections than other facilities. The two-spot method prevented 10 504 specimen rejections. The Pearson correlation coefficient comparing the standard to the two-spot method was 0.997. The two-spot method was comparable with the standard method of pre-analytical specimen processing. Two health facilities were identified for targeted retraining on specimen quality. The two-spot method of DBS specimen processing can be used as an adjunct to retraining, to reduce the number of specimens rejected and improve linkage to care.
Cox, Holly D; Eichner, Daniel
2017-09-19
The dried blood spot (DBS) matrix has significant utility for applications in the field where venous blood collection and timely shipment of labile blood samples is difficult. Unfortunately, protein measurement in DBS is hindered by high abundance proteins and matrix interference that increases with hematocrit. We developed a DBS method to enrich for membrane proteins and remove soluble proteins and matrix interference. Following a wash in a series of buffers, the membrane proteins are digested with trypsin and quantitated by parallel reaction monitoring mass spectrometry methods. The DBS method was applied to the quantification of four cell-specific cluster of differentiation (CD) proteins used to count cells by flow cytometry, band 3 (CD233), CD71, CD45, and CD41. We demonstrate that the DBS method counts low abundance cell types such as immature reticulocytes as well as high abundance cell types such as red blood cells, white blood cells, and platelets. When tested in 82 individuals, counts obtained by the DBS method demonstrated good agreement with flow cytometry and automated hematology analyzers. Importantly, the method allows longitudinal monitoring of CD protein concentration and calculation of interindividual variation which is difficult by other methods. Interindividual variation of band 3 and CD45 was low, 6 and 8%, respectively, while variation of CD41 and CD71 was higher, 18 and 78%, respectively. Longitudinal measurement of CD71 concentration in DBS over an 8-week period demonstrated intraindividual variation 17.1-38.7%. Thus, the method may allow stable longitudinal measurement of blood parameters currently monitored to detect blood doping practices.
Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.
Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil
2015-10-01
Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Siebenhaar, Markus; Küllmer, Kai; Fernandes, Nuno Miguel de Barros; Hüllen, Volker; Hopf, Carsten
2015-09-01
Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.
Waitt, Catriona; Diliiy Penchala, Sujan; Olagunju, Adeniyi; Amara, Alieu; Else, Laura; Lamorde, Mohammed; Khoo, Saye
2017-08-15
To present the validation and clinical application of a LC-MS/MS method for the quantification of lamivudine (3TC), emtricitabine (FTC) and tenofovir (TFV) in dried blood spots (DBS) and dried breast milk spots (DBMS). DBS and DBMS were prepared from 50 and 30μL of drug-spiked whole blood and human breast milk, respectively. Following extraction with acetonitrile and water, chromatographic separation utilised a Synergi polar column with a gradient mobile phase program consisting of 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Detection and quantification was performed using a TSQ Quantum Ultra triple quadrupole mass spectrometer. The analytical method was used to evaluate NRTI drug levels in HIV-positive nursing mothers-infant pairs. The assay was validated over the concentration range of 16.6-5000ng/mL for 3TC, FTC and TFV in DBS and DBMS except for TFV in DBMS where linearity was established from 4.2-1250ng/mL. Intra and inter-day precision (%CV) ranged from 3.5-8.7 and accuracy was within 15% for all analytes in both matrices. The mean recovery in DBS was >61% and in DBMS >43% for all three analytes. Matrix effect was insignificant. Median AUC 0-8 values in maternal DBS and DBMS, respectively, were 4683 (4165-6057) and 6050 (5217-6417)ngh/mL for 3TC, 3312 (2259-4312) and 4853 (4124-6691)ngh/mL for FTC and 1559 (930-1915) and 56 (45-80)ngh/mL for TFV. 3TC and FTC were quantifiable (>16.6ng/mL) in DBS from 2/6 and 1/6 infants respectively whereas TFV was undetectable in all infants. DBS and DBMS sampling for bioanalysis of 3TC, FTC and TFV is straightforward, robust, accurate and precise, and ideal for use in low-resource settings. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Shokry, Engy; Villanelli, Fabio; Malvagia, Sabrina; Rosati, Anna; Forni, Giulia; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria; Guerrini, Renzo; la Marca, Giancarlo
2015-05-10
Carbamazepine (CBZ) is a first-line drug for the treatment of different forms of epilepsy and the first choice drug for trigeminal neuralgia. CBZ is metabolized in the liver by oxidation into carbamazepine-10,11-epoxide (CBZE), its major metabolite which is equipotent and known to contribute to the pharmacological activity of CBZ. The aim of the present study was to develop and validate a reliable, selective and sensitive liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of CBZ and its active metabolite in dried blood spots (DBS). The extraction process was carried out from DBS using methanol-water-formic acid (80:20:0.1, v/v/v). Chromatographic elution was achieved by using a linear gradient with a mobile phase consisting of acetonitrile-water-0.1% formic acid at a flow rate of 0.50mL/min. The method was linear over the range 1-40mg/L and 0.25-20mg/L for CBZ and CBZE, respectively. The limit of quantification was 0.75mg/L and 0.25mg/L for CBZ and CBZE. Intra-day and inter-day assay precisions were found to be lower than 5.13%, 6.46% and 11.76%, 4.72% with mean percentage accuracies of 102.1%, 97.5% and 99.2%, 97.8% for CBZ and CBZE. We successfully applied the method for determining DBS finger-prick samples in paediatric patients and confirmed the results with concentrations measured in matched plasma samples. This novel approach allows quantification of CBZ and its metabolite from only one 3.2mm DBS disc by LC-MS/MS thus combining advantages of DBS technique and LC-MS/MS in clinical practice. Copyright © 2015 Elsevier B.V. All rights reserved.
Iroh Tam, Pui-Ying; Hernandez-Alvarado, Nelmary; Schleiss, Mark R.; Hassan-Hanga, Fatimah; Onuchukwu, Chuma; Umoru, Dominic; Obaro, Stephen K.
2016-01-01
Background Nigeria has one of the highest burdens of pneumococcal disease in the world, but accurate surveillance is lacking. Molecular detection of infectious pathogens in dried blood spots (DBS) is an ideal method for surveillance of infections in resource-limited settings because of its low cost, minimal blood volumes involved, and ease of storage at ambient temperature. Our study aim was to evaluate a Streptococcus pneumoniae real-time polymerase chain reaction (rt-PCR) assay on DBS from febrile Nigerian children on Whatman 903 and FTA filter papers, compared to the gold standard of culture. Methods Between September 2011 to May 2015, blood was collected from children 5 years of age or under who presented to six hospital study sites throughout northern and central Nigeria with febrile illness, and inoculated into blood culture bottles or spotted onto Whatman 903 or FTA filter paper. Culture and rt-PCR were performed on all samples. Results A total of 537 DBS specimens from 535 children were included in the study, of which 15 were culture-positive for S. pneumoniae. The rt-PCR assay detected S. pneumoniae in 12 DBS specimens (2.2%). One positive rt-PCR result was identified in a culture-negative specimen from a high-risk subject, and two positive rt-PCR results were negative on repeat testing. Six culture-confirmed cases of S. pneumoniae bacteremia were missed. Compared to culture, the overall sensitivities of Whatman 903 and FTA DBS for detection of S. pneumoniae were 57.1% (95% CI 18.4–90.1%) and 62.5% (95% CI 24.5–91.5%), respectively. Nonspecific amplification was noted in an additional 22 DBS (4.1%). Among these, six were positive for a non-S. pneumoniae pathogen on culture. Conclusions Rt-PCR was able to detect S. pneumoniae from clinical DBS specimens, including from a culture-negative specimen. Our findings show promise of this approach as a surveillance diagnostic, but also raise important cautionary questions. Several DBS specimens were detected as S. pneumoniae by rt-PCR despite growth of a non-S. pneumoniae pathogen on culture. A precise definition of what constitutes a positive result is required to avoid falsely over-identifying specimens. PMID:27007889
Low-Cost HIV-1 Diagnosis and Quantification in Dried Blood Spots by Real Time PCR
Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A. S.; Eliot, Melissa N.; Lin, Rongheng; Foulkes, Andrea S.; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L.; Luzuriaga, Katherine; Somasundaran, Mohan
2009-01-01
Background Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. Methods and Findings We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log10, and %CV <8% up to 4 log10 dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. Conclusions The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings. PMID:19503790
Low-cost HIV-1 diagnosis and quantification in dried blood spots by real time PCR.
Mehta, Nishaki; Trzmielina, Sonia; Nonyane, Bareng A S; Eliot, Melissa N; Lin, Rongheng; Foulkes, Andrea S; McNeal, Kristina; Ammann, Arthur; Eulalievyolo, Vindu; Sullivan, John L; Luzuriaga, Katherine; Somasundaran, Mohan
2009-06-05
Rapid and cost-effective methods for HIV-1 diagnosis and viral load monitoring would greatly enhance the clinical management of HIV-1 infected adults and children in limited-resource settings. Recent recommendations to treat perinatally infected infants within the first year of life are feasible only if early diagnosis is routinely available. Dried blood spots (DBS) on filter paper are an easy and convenient way to collect and transport blood samples. A rapid and cost effective method to diagnose and quantify HIV-1 from DBS is urgently needed to facilitate early diagnosis of HIV-1 infection and monitoring of antiretroviral therapy. We have developed a real-time LightCycler (rtLC) PCR assay to detect and quantify HIV-1 from DBS. HIV-1 RNA extracted from DBS was amplified in a one-step, single-tube system using primers specific for long-terminal repeat sequences that are conserved across all HIV-1 clades. SYBR Green dye was used to quantify PCR amplicons and HIV-1 RNA copy numbers were determined from a standard curve generated using serially diluted known copies of HIV-1 RNA. This assay detected samples across clades, has a dynamic range of 5 log(10), and %CV <8% up to 4 log(10) dilution. Plasma HIV-1 RNA copy numbers obtained using this method correlated well with the Roche Ultrasensitive (r = 0.91) and branched DNA (r = 0.89) assays. The lower limit of detection (95%) was estimated to be 136 copies. The rtLC DBS assay was 2.5 fold rapid as well as 40-fold cheaper when compared to commercial assays. Adaptation of the assay into other real-time systems demonstrated similar performance. The accuracy, reliability, genotype inclusivity and affordability, along with the small volumes of blood required for the assay suggest that the rtLC DBS assay will be useful for early diagnosis and monitoring of pediatric HIV-1 infection in resource-limited settings.
Zeh, Clement; Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John
2017-01-01
Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2-99.2] and 98.1% [95%CI: 89.7-100]) and those for DBS (93.9% [95%CI: 88.8-97.2] and 88.0% [95%CI: 82.2-92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4-97.7) and 73.6 (95%CI: 51.6-86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6-100.0] vs. 94.7% [95%CI: 89.8-97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4-13.7] compared to DPS: 94.0%, [95% CI: 83.5-98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8-98.7] and 90.4% [95% CI 78.2-96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3-97.5] and 98.1% [95%CI 88.4-99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0-98.3] and specificity of 82.7% [95%CI 69.2-91.3]). There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings.
Ndiege, Kenneth; Inzaule, Seth; Achieng, Rebecca; Williamson, John; Chih-Wei Chang, Joy; Ellenberger, Dennis; Nkengasong, John
2017-01-01
Background Routine HIV viral load testing is not widely accessible in most resource-limited settings, including Kenya. To increase access to viral load testing, alternative sample types like dried blood spots (DBS), which overcome the logistic barriers associated with plasma separation and cold chain shipment need to be considered and evaluated. The current study evaluated matched dried blood spots (DBS) and dried plasma spots (DPS) against plasma using the Abbott M 2000 (Abbott) and Roche Cobas Ampliprep/Cobas TaqMan (CAP/CTM) quantitative viral load assays in western Kenya. Methods Matched plasma DBS and DPS were obtained from 200 HIV-1 infected antiretroviral treatment (ART)-experienced patients attending patient support centers in Western Kenya. Standard quantitative assay performance parameters with accompanying 95% confidence intervals (CI) were assessed at the assays lower detection limit (400cps/ml for CAP/CTM and 550cps/ml for Abbott) using SAS version 9.2. Receiver operating curves (ROC) were further used to assess viral-load thresholds with best assay performance (reference assay CAP/CTM plasma). Results Using the Abbott test, the sensitivity and specificity, respectively, for DPS were (97.3%, [95%CI: 93.2–99.2] and 98.1% [95%CI: 89.7–100]) and those for DBS (93.9% [95%CI: 88.8–97.2] and 88.0% [95%CI: 82.2–92.4]). The correlation and agreement using paired plasma and DPS/DBS were strong, with r2 = 90.5 and rc = 68.1. The Bland-Altman relative percent change was 95.3 for DPS, (95%CI: 90.4–97.7) and 73.6 (95%CI: 51.6–86.5) for DBS. Using the CAP/CTM assay, the sensitivity for DBS was significantly higher compared to DPS (100.0% [95% CI: 97.6–100.0] vs. 94.7% [95%CI: 89.8–97.7]), while the specificity for DBS was lower: 4%, [95% CI: 0.4–13.7] compared to DPS: 94.0%, [95% CI: 83.5–98.7]. When compared under different clinical relevant thresholds, the accuracy for the Abbott assay was 95% at the 1000cps/ml cut-off with a sensitivity and specificity of 96.6% [95% CI 91.8–98.7] and 90.4% [95% CI 78.2–96.4] respectively. The optimum threshold was at 3000 cps/ml with an accuracy of 95.5%, sensitivity and specificity of 94.6% [95%CI 89.3–97.5] and 98.1% [95%CI 88.4–99.9]) respectively. The best threshold for CAP/CTM was at 4000 copies /mL, with 92.5% accuracy (sensitivity of 96.0% [95%CI 91.0–98.3] and specificity of 82.7% [95%CI 69.2–91.3]). Conclusions There was similar performance between matched DBS, DPS and plasma using the Abbott test, and good correlation for matched DPS and plasma using the CAPCTM test. The findings suggest that DBS and DPS may be reliably used as alternative specimens to plasma to measure HIV-1 VL using Abbott, and DPS may be reliably used with CAP/CTM in resource-limited settings. PMID:28622370
Atkinson, C; Emery, V C; Griffiths, P D
2014-02-01
Newborn screening for congenital cytomegalovirus (CCMV) using dried blood spots (DBS) has been proposed because many developed countries have DBS screening programmes in place for other diseases. The aim of this study was to develop a rapid, single tube nested polymerase chain reaction (PCR) method for enhanced detection of CMV from DBS compared to existing (single target) real time PCRs. The new method was compared with existing real time PCRs for sensitivity and specificity. Overall sensitivity of the single target PCR assays in both asymptomatic and symptomatic infants with laboratory confirmed congenital CMV was 69% (CMV PCR or culture positive before day 21 of life). In contrast, the single tube nested assay had an increased sensitivity of 81% with100% specificity. Overall the assay detected CMV from a DBS equivalent to an original blood sample which contained 500IU/ml. In conclusion this single tube nested methodology allows simultaneous amplification and detection of CMV DNA in 1.5h removing the associated contamination risk of a two step nested PCR. Owing to its increased sensitivity, it has the potential to be used as a screening assay and ultimately allow early identification and intervention for children with congenital CMV. Copyright © 2013 Elsevier B.V. All rights reserved.
Vázquez-Morón, Sonia; Ryan, Pablo; Ardizone-Jiménez, Beatriz; Martín, Dolores; Troya, Jesus; Cuevas, Guillermo; Valencia, Jorge; Jimenez-Sousa, María A; Avellón, Ana; Resino, Salvador
2018-01-30
Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.
Modification of CMV DNA detection from dried blood spots for diagnosing congenital CMV infection.
Binda, Sandro; Caroppo, Simona; Didò, Patrizia; Primache, Valeria; Veronesi, Licia; Calvario, Agata; Piana, Andrea; Barbi, Maria
2004-07-01
Detection of viral DNA in dried blood spots using the Guthrie card (DBS test) is a reliable and practical method of diagnosing congenital cytomegalovirus (CMV) infection. The test lends itself to epidemiological studies to establish the prevalence of the infection, but also to neonatal screening for secondary prevention of sequelae. These applications would be facilitated if it were possible to use smaller samples and do the test on pools of individual cases. To ascertain whether doing the test on smaller, pooled samples still accurately identifies neonates with congenital CMV infection. We tested DBS from: (A) 39 laboratory reference cases; (B) 156 neonates suspected of having congenital CMV infection; (C) 119 children examined for the retrospective diagnosis of congenital CMV; (D) mock specimens prepared with known amounts of viral DNA. The test using only one third of the usual amount of dried blood was 100% sensitive and specific compared to the standard DBS test (A) and to viral isolation (A and B). Pools of three single cases gave the same results as viral isolation (B) and the small-sample test (B and C). All the versions of the test gave a detection limit of 400 copies/ml. The modified procedure can accurately diagnose congenital CMV infection. It achieves savings in both the patient material and the costs of testing.
Sista, Ramakrishna S; Wang, Tong; Wu, Ning; Graham, Carrie; Eckhardt, Allen; Winger, Theodore; Srinivasan, Vijay; Bali, Deeksha; Millington, David S; Pamula, Vamsee K
2013-09-23
New therapies for lysosomal storage diseases (LSDs) have generated interest in screening newborns for these conditions. We present performance validation data on a digital microfluidic platform that performs multiplex enzymatic assays for Pompe, Fabry, Hunter, Gaucher, and Hurler diseases. We developed an investigational disposable digital microfluidic cartridge that uses a single dried blood spot (DBS) punch for performing a 5-plex fluorometric enzymatic assay on up to 44 DBS samples. Precision and linearity of the assays were determined by analyzing quality control DBS samples; clinical performance was determined by analyzing 600 presumed normal and known affected samples (12 for Pompe, 7 for Fabry and 10 each for Hunter, Gaucher and Hurler). Overall coefficient of variation (CV) values between cartridges, days, instruments, and operators ranged from 2 to 21%; linearity correlation coefficients were ≥0.98 for all assays. The multiplex enzymatic assay performed from a single DBS punch was able to discriminate presumed normal from known affected samples for 5 LSDs. Digital microfluidic technology shows potential for rapid, high-throughput screening for 5 LSDs in a newborn screening laboratory environment. Sample preparation to enzymatic activity on each cartridge is less than 3h. Copyright © 2013 Elsevier B.V. All rights reserved.
Elbin, Carole S; Olivova, Petra; Marashio, Carla A; Cooper, Samantha K; Cullen, Emmaline; Keutzer, Joan M; Zhang, X Kate
2011-06-11
Fluorometric and tandem mass spectrometry assays can be used to measure lysosomal enzyme activities in dried blood spots (DBS). The effect of DBS preparation, storage and shipping was evaluated on the activities of acid α-glucosidase, acid α-galactosidase, acid β-glucocerebrosidase, acid sphingomyelinase, and galactocerebrosidase. Whole blood from normal donors was used to prepare DBS following Clinical and Laboratory Standards Institute guidelines and by several deviations. Some DBS were subjected to various treatments, storage and shipping conditions. The activity of 5 lysosomal enzymes (GAA, GLA, GBA, ASM, and GALC) was measured using tandem mass spectrometric and fluorometric (GAA only) assays with 2 distinct and commonly used synthetic substrates. Enzyme activities were strongly affected by the way DBS were prepared and stored. Exposure of DBS to elevated heat and humidity can destroy enzyme functions rapidly. DBS prepared from poorly mixed blood caused significant variation on enzyme activities. EDTA, but not heparin, as an anti-coagulant gave more precise results. The study confirmed the importance of proper and consistent DBS preparation and storage when screening for deficiencies of lysosomal enzymes. Copyright © 2011 Elsevier B.V. All rights reserved.
High density FTA plates serve as efficient long-term sample storage for HLA genotyping.
Lange, V; Arndt, K; Schwarzelt, C; Boehme, I; Giani, A S; Schmidt, A H; Ehninger, G; Wassmuth, R
2014-02-01
Storage of dried blood spots (DBS) on high-density FTA(®) plates could constitute an appealing alternative to frozen storage. However, it remains controversial whether DBS are suitable for high-resolution sequencing of human leukocyte antigen (HLA) alleles. Therefore, we extracted DNA from DBS that had been stored for up to 4 years, using six different methods. We identified those extraction methods that recovered sufficient high-quality DNA for reliable high-resolution HLA sequencing. Further, we confirmed that frozen whole blood samples that had been stored for several years can be transferred to filter paper without compromising HLA genotyping upon extraction. Concluding, DNA derived from high-density FTA(®) plates is suitable for high-resolution HLA sequencing, provided that appropriate extraction protocols are employed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Hyperspectral imaging and multivariate analysis in the dried blood spots investigations
NASA Astrophysics Data System (ADS)
Majda, Alicja; Wietecha-Posłuszny, Renata; Mendys, Agata; Wójtowicz, Anna; Łydżba-Kopczyńska, Barbara
2018-04-01
The aim of this study was to apply a new methodology using the combination of the hyperspectral imaging and the dry blood spot (DBS) collecting. Application of the hyperspectral imaging is fast and non-destructive. DBS method offers the advantage also on the micro-invasive blood collecting and low volume of required sample. During experimental step, the reflected light was recorded by two hyperspectral systems. The collection of 776 spectral bands in the VIS-NIR range (400-1000 nm) and 256 spectral bands in the SWIR range (970-2500 nm) was applied. Pixel has the size of 8 × 8 and 30 × 30 µm for VIS-NIR and SWIR camera, respectively. The obtained data in the form of hyperspectral cubes were treated with chemometric methods, i.e., minimum noise fraction and principal component analysis. It has been shown that the application of these methods on this type of data, by analyzing the scatter plots, allows a rapid analysis of the homogeneity of DBS, and the selection of representative areas for further analysis. It also gives the possibility of tracking the dynamics of changes occurring in biological traces applied on the surface. For the analyzed 28 blood samples, described method allowed to distinguish those blood stains because of time of apply.
Sozmen, Eser Yıldırım; Sezer, Ebru Demirel
2017-01-01
The lysosomal storage diseases (LDSs) are a heterogeneous group of inherited genetic disorders caused by defects of lysosomal proteins. The accumulation of undigested substrates from different catabolic pathways leads to cellular dysfunction. LSDs generally presents during early childhood and have a devastating impact on the families and on public health. Over the years, approaches for treatment of some LSDs have been developed with different strategies. Increasing availability of treatments of these diseases has accelerated the development of new methods and techniques for rapid diagnosis in patients with clinical indication.The use of dried blood spot (DBS) test has been proposed as a first tier test to identify patients with Gaucher, Pompe, and Fabry diseases. DBS usage is advantageous for the purpose of screening as it is non-invasive, sensitive, has low-cost and fast turnaround time compared to measurements in leucocyte and/or fibroblast culture. This chapter focuses on the activity measurement of three lysosomal enzymes (α-glucosidase, β-glucosidase, and α galactosidase) in DBS samples by using fluorescent substrates and by the LC-MS/MS (liquid chromatography-mass spectrometry) method. All steps of the methods, from preparation of the solutions to calculation of the enzyme activity, will be explained in detail.
Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana
2017-10-25
In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.
Metal nanoparticles in DBS card materials modification
NASA Astrophysics Data System (ADS)
Metelkin, A.; Frolov, G.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.
2015-11-01
In the recent years the method of collecting and storing Dried Blood Spots (DBS) on special cellulose membrane (paper) has gained wide popularity. But possible damage of biosamples caused by microorganisms in case of their incomplete drying is a disadvantage of the method. It can be overcome by treating sample-collection membranes with colloidal solutions of metal nanoparticles, having antibacterial effect. The team studied antibacterial properties of nonwoven material samples with various coatings (alcohol sols of copper, aluminium, iron, titanium, silver and vanadium nanoparticles). Colloidal solutions of nanoparticles were obtained by means of electroerosion method with further low-temperature plasma condensation. Antibacterial activity of fiberglass and cellulose membrane samples with nanoparticle coatings was studied using B. cereus and plaque bacteria cultures. It was revealed that nanostructured coatings can suppress bacterial activity; in addition they can diffuse from the membrane surface into medium which leads to widening the areas of inhibiting testing cultures’ growth. Thus, membrane materials treatment with alcohol-sols of metal nanoparticles can be seen as promising for conferring antibacterial properties to DBS carriers.
Waitt, Catriona; Olagunju, Adeniyi; Nakalema, Shadia; Kyohaire, Isabella; Owen, Andrew; Lamorde, Mohammed; Khoo, Saye
2018-01-01
Abstract Background Breast milk transfer of first-line ART from mother to infant is not fully understood. Objectives To determine the concentrations of lamivudine, emtricitabine and tenofovir in maternal blood, breast milk and infant blood from breastfeeding mother–infant pairs. Methods Intensive pharmacokinetic sampling of maternal dried blood spots (DBS), dried breast milk spots (DBMS) and infant DBS from 30 Ugandan and 29 Nigerian mothers receiving first-line ART and their infants was conducted. DBS and DBMS were collected pre-dose and at 5–6 timepoints up to 12 h following observed dosing. Infant DBS were sampled twice during this period. Lamivudine, emtricitabine and tenofovir were quantified using LC-MS/MS, with non-compartmental analysis to calculate key pharmacokinetic parameters. Results Peak concentrations in breast milk from women taking lamivudine and emtricitabine occurred later than in plasma (4–8 h compared with 2 h for lamivudine and 2–4 h for emtricitabine). Consequently, the milk-to-plasma (M:P) ratio of lamivudine taken once daily was 0.95 (0.82–1.15) for AUC0–12, whereas for AUC12–20 this was 3.04 (2.87–4.16). Lamivudine was detectable in 36% (14/39) of infants [median 17.7 (16.3–22.7) ng/mL]. For 200 mg of emtricitabine once daily, the median M:P ratio was 3.01 (2.06–3.38). Three infants (19%) had measurable emtricitabine [median 18.5 (17.6–20.8) ng/mL]. For 300 mg of tenofovir once daily, the median M:P ratio was 0.015 (0–0.03) and no infant had measurable tenofovir concentrations. Conclusions Emtricitabine and lamivudine accumulate in breast milk and were detected in breastfeeding infants. In contrast, tenofovir penetrates the breast milk to a small degree, but is undetectable in breastfeeding infants. PMID:29309634
Waitt, Catriona; Olagunju, Adeniyi; Nakalema, Shadia; Kyohaire, Isabella; Owen, Andrew; Lamorde, Mohammed; Khoo, Saye
2018-04-01
Breast milk transfer of first-line ART from mother to infant is not fully understood. To determine the concentrations of lamivudine, emtricitabine and tenofovir in maternal blood, breast milk and infant blood from breastfeeding mother-infant pairs. Intensive pharmacokinetic sampling of maternal dried blood spots (DBS), dried breast milk spots (DBMS) and infant DBS from 30 Ugandan and 29 Nigerian mothers receiving first-line ART and their infants was conducted. DBS and DBMS were collected pre-dose and at 5-6 timepoints up to 12 h following observed dosing. Infant DBS were sampled twice during this period. Lamivudine, emtricitabine and tenofovir were quantified using LC-MS/MS, with non-compartmental analysis to calculate key pharmacokinetic parameters. Peak concentrations in breast milk from women taking lamivudine and emtricitabine occurred later than in plasma (4-8 h compared with 2 h for lamivudine and 2-4 h for emtricitabine). Consequently, the milk-to-plasma (M:P) ratio of lamivudine taken once daily was 0.95 (0.82-1.15) for AUC0-12, whereas for AUC12-20 this was 3.04 (2.87-4.16). Lamivudine was detectable in 36% (14/39) of infants [median 17.7 (16.3-22.7) ng/mL]. For 200 mg of emtricitabine once daily, the median M:P ratio was 3.01 (2.06-3.38). Three infants (19%) had measurable emtricitabine [median 18.5 (17.6-20.8) ng/mL]. For 300 mg of tenofovir once daily, the median M:P ratio was 0.015 (0-0.03) and no infant had measurable tenofovir concentrations. Emtricitabine and lamivudine accumulate in breast milk and were detected in breastfeeding infants. In contrast, tenofovir penetrates the breast milk to a small degree, but is undetectable in breastfeeding infants.
Tran, Tuan M; Aghili, Amirali; Li, Shanping; Ongoiba, Aissata; Kayentao, Kassoum; Doumbo, Safiatou; Traore, Boubacar; Crompton, Peter D
2014-10-04
As public health efforts seek to eradicate malaria, there has been an emphasis on eliminating low-density parasite reservoirs in asymptomatic carriers. As such, diagnosing submicroscopic Plasmodium infections using PCR-based techniques has become important not only in clinical trials of malaria vaccines and therapeutics, but also in active malaria surveillance campaigns. However, PCR-based quantitative assays that rely on nucleic acid extracted from dried blood spots (DBS) have demonstrated lower sensitivity than assays that use cryopreserved whole blood as source material. The density of Plasmodium falciparum asexual parasites was quantified using genomic DNA extracted from dried blood spots (DBS) and the sensitivity of two approaches was compared: quantitative real-time PCR (qPCR) targeting the P. falciparum 18S ribosomal RNA gene, either with an initial conventional PCR amplification prior to qPCR (nested qPCR), or without an initial amplification (qPCR only). Parasite densities determined by nested qPCR, qPCR only, and light microscopy were compared. Nested qPCR results in 10-fold higher sensitivity (0.5 parasites/μl) when compared to qPCR only (five parasites/ul). Among microscopy-positive samples, parasite densities calculated by nested qPCR correlated strongly with microscopy for both asymptomatic (Pearson's r=0.58, P<0.001) and symptomatic (Pearson's r=0.70, P<0.0001) P. falciparum infections. Nested qPCR improves the sensitivity for the detection of P. falciparum blood-stage infection from clinical DBS samples. This approach may be useful for active malaria surveillance in areas where submicroscopic asymptomatic infections are prevalent.
Balduyck, Malika; Chapuis Cellier, Colette; Roche, Denis; Odou, Marie-Françoise; Joly, Philippe; Madelain, Vincent; Vergne, Anita; Nouadje, Georges; Lafitte, Jean-Jacques; Porchet, Nicole; Beaune, Philippe; Zerimech, Farid
2014-01-01
Alpha- 1-antitrypsin (A1AT) deficiency is a hereditary autosomal codominant genetic disorder resulting in low circulating levels of A1AT and leading to lung and/or liver disease. It remains underdiagnosed and only 5 to 10% of PIZZ patients, the most common form of severe A1AT deficiency, would be actually identified in France. Facilitating early diagnosis of A1AT deficiency would allow a better management of this disease; therefore we have developed and standardized in three laboratories involved in this study, a diagnostic test on dried blood spots (DBS) including quantitative A1AT measurement, phenotyping by IEF electrophoresis and, if necessary, genotyping by SERPINA1 gene sequencing. We performed a quantitative assay on 90 DBS samples by immunoturbidimetric or immunonephelometric methods. We demonstrated that both methods were suitable for this type of sampling and the results obtained were highly correlated (R(2)>0.9) between the three laboratories: for a target value of 1.00 g/L, the results obtained from the three laboratories were between 1.00 and 1.02 g/L. Phenotyping and genotyping were performed under redefined operating conditions and adapted to the analysis of DBS samples. The results were comparable with those obtained for venous blood samples. Following this work, it becomes possible to provide pulmonologists with a reliable kit to perform a capillary blood sampling on filter paper which would allow a large-scale screening of A1AT deficiency in the population particularly affected by this genetic condition.
Tretzel, Laura; Thomas, Andreas; Piper, Thomas; Hedeland, Mikael; Geyer, Hans; Schänzer, Wilhelm; Thevis, Mario
2016-05-10
Dried blood spots (DBS) represent a sample matrix collected under minimal-invasive, straightforward and robust conditions. DBS specimens have been shown to provide appropriate test material for different analytical disciplines, e.g., preclinical drug development, therapeutic drug monitoring, forensic toxicology and diagnostic analysis of metabolic disorders in newborns. However, the sample preparation has occasionally been reported as laborious and time consuming. In order to minimize the manual workload and to substantiate the suitability of DBS for high sample-throughput, the automation of sample preparation processes is of paramount interest. In the current study, the development and validation of a fully automated DBS extraction method coupled to online solid-phase extraction using the example of nicotine, its major metabolites nornicotine, cotinine and trans-3'-hydroxycotinine and the tobacco alkaloids anabasine and anatabine is presented, based on the rationale that the use of nicotine-containing products for performance-enhancing purposes has been monitored by the World Anti-Doping Agency (WADA) for several years. Automation-derived DBS sample extracts were directed online to liquid chromatography high resolution/high mass accuracy tandem mass spectrometry, and target analytes were determined with support of four deuterated internal standards. Validation of the method yielded precise (CV <7.5% for intraday and <12.3% for interday measurements) and linear (r(2)>0.998) results. The limit of detection was established at 5 ng mL(-1) for all studied compounds, the extraction recovery ranged from 25 to 44%, and no matrix effects were observed. To exemplify the applicability of the DBS online-SPE LC-MS/MS approach for sports drug testing purposes, the method was applied to authentic DBS samples obtained from smokers, snus users, and e-cigarette users. Statistical evaluation of the obtained results indicated differences in metabolic behavior depending on the route of administration (inhalative versus buccal absorption) in terms of the ratio of nicotine and nornicotine. Copyright © 2016 Elsevier B.V. All rights reserved.
Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung
2017-10-25
Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were < 2min. The relative standard deviations of within-run and between-run precisions for peak area ratios were all < 17.3%. Accuracies were 91.5-111.2% for lower limit of quantification, low, medium, and high QC samples. The stability of the easily hydrolyzed prodrug, colistin methanesulfonate, was investigated in DBSs. Less than 4% of the prodrug was found to be hydrolyzed in DBSs at room temperature after 48h. The developed method applied an on-spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.
Page-Sharp, Madhu; Strunk, Tobias; Salman, Sam; Hibbert, Julie; Patole, Sanjay K; Manning, Laurens; Batty, Kevin T
2017-11-30
Advances in bioanalytical methods are facilitating micro-volume and dried blood spot (DBS) analysis of drugs in biological matrices for pharmacokinetic studies in children and neonates. We sought to develop a UPLC-MS/MS assay for simultaneous measurement of caffeine, pentoxifylline (PTX) and three metabolites of PTX in both plasma and DBS. Caffeine, PTX, the metabolites M1 (lisofylline), M4 and M5, and the internal standards (caffeine-d 9 and PTX-d 6 ) were separated using a Waters Aquity T3 UPLC C 18 column and gradient mobile phase (water-methanol-formic acid). Retention times for caffeine, M5, M4, PTX and M1 were 1.6, 1.7, 1.9, 2.0 and 2.1min, respectively, with a run time of 5min. The precision (≤10%) and accuracy (≤15%) across the concentration range 0.1-50mg/L for caffeine, PTX and the three metabolites in plasma and DBS were within accepted limits, as were the limits of quantification (100μg/L for caffeine and 10μg/L for PTX, M1, M4 and M5). Caffeine, PTX and the metabolites were stable in DBS for >34days at room and refrigerated temperatures. Plasma and DBS samples were obtained from 24 preterm infants recruited into a clinical pharmacokinetic study of PTX. Paired analysis indicated that DBS concentrations were 9% lower than concurrent plasma concentrations for caffeine, 7% lower for PTX (consistent with the blood:plasma ratio) and 13% lower for M1 (lisofylline). The validated UPLC-MS/MS method is suitable for micro-volume plasma and DBS analysis of caffeine, PTX and its metabolites for pharmacokinetic studies in paediatric patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Novel application of digital microfluidics for the detection of biotinidase deficiency in newborns.
Graham, Carrie; Sista, Ramakrishna S; Kleinert, Jairus; Wu, Ning; Eckhardt, Allen; Bali, Deeksha; Millington, David S; Pamula, Vamsee K
2013-12-01
Newborn screening for biotinidase deficiency can be performed using a fluorometric enzyme assay on dried blood spot specimens. As a pre-requisite to the consolidation of different enzymatic assays onto a single platform, we describe here a novel analytical method for detecting biotinidase deficiency using the same digital microfluidic cartridge that has already been demonstrated to screen for five lysosomal storage diseases (Pompe, Fabry, Gaucher, Hurler and Hunter) in a multiplex format. A novel assay to quantify biotinidase concentration in dried blood spots (DBS) was developed and optimized on the digital microfluidic platform using proficiency testing samples from the Centers for Disease Control and Prevention. The enzymatic assay uses 4-methylumbelliferyl biotin as the fluorogenic substrate. Biotinidase deficiency assays were performed on normal (n=200) and deficient (n=7) newborn DBS specimens. Enzymatic activity analysis of biotinidase deficiency revealed distinct separation between normal and affected DBS specimens using digital microfluidics and these results matched the expected activity. This study has demonstrated performance of biotinidase deficiency assays by measurement of 4-methylumbelliferyl product on a digital microfluidic platform. Due to the inherent ease in multiplexing on such a platform, consolidation of other fluorometric assays onto a single cartridge may be realized. © 2013.
Field study of dried blood spot specimens for HIV-1 drug resistance genotyping.
Parry, C M; Parkin, N; Diallo, K; Mwebaza, S; Batamwita, R; DeVos, J; Bbosa, N; Lyagoba, F; Magambo, B; Jordan, M R; Downing, R; Zhang, G; Kaleebu, P; Yang, C; Bertagnolio, S
2014-08-01
Dried blood spots (DBS) are an alternative specimen type for HIV drug resistance genotyping in resource-limited settings. Data relating to the impact of DBS storage and shipment conditions on genotyping efficiency under field conditions are limited. We compared the genotyping efficiencies and resistance profiles of DBS stored and shipped at different temperatures to those of plasma specimens collected in parallel from patients receiving antiretroviral therapy in Uganda. Plasma and four DBS cards from anti-coagulated venous blood and a fifth card from finger-prick blood were prepared from 103 HIV patients with a median viral load (VL) of 57,062 copies/ml (range, 1,081 to 2,964,191). DBS were stored at ambient temperature for 2 or 4 weeks or frozen at -80 °C and shipped from Uganda to the United States at ambient temperature or frozen on dry ice for genotyping using a broadly sensitive in-house method. Plasma (97.1%) and DBS (98.1%) stored and shipped frozen had similar genotyping efficiencies. DBS stored frozen (97.1%) or at ambient temperature for 2 weeks (93.2%) and shipped at ambient temperature also had similar genotyping efficiencies. Genotyping efficiency was reduced for DBS stored at ambient temperature for 4 weeks (89.3%, P = 0.03) or prepared from finger-prick blood and stored at ambient temperature for 2 weeks (77.7%, P < 0.001) compared to DBS prepared from venous blood and handled similarly. Resistance profiles were similar between plasma and DBS specimens. This report delineates the optimal DBS collection, storage, and shipping conditions and opens a new avenue for cost-saving ambient-temperature DBS specimen shipments for HIV drug resistance (HIVDR) surveillances in resource-limited settings. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
Alcaide, Maria L; Ramlagan, Shandir; Rodriguez, Violeta J; Cook, Ryan; Peltzer, Karl; Weiss, Stephen M; Sifunda, Sibusiso; Jones, Deborah L
2017-07-01
Antiretroviral (ARV) adherence is essential to prevent mother-to-child transmission of HIV. This study compared self-reported adherence versus ARV detection in dried blood spots (DBS) among N = 392 HIV-infected pregnant women in South Africa (SA). Women completed two self-reported adherence measures [visual analog scale (VAS), AIDS Clinical Trials Group Adherence (ACTG)]. Adherence was 89% (VAS), 80% (ACTG), and 74% (DBS). Self-report measures marginally agreed with DBS (VAS: Kappa = 0.101, Area under the ROC curve (AUROC) = 0.543; ACTG: Kappa = 0.081, AUROC = 0.538). Self-reported adherence was overestimated and agreement with DBS was poor. Validation of self-reported ARV adherence among pregnant HIV+ women in SA is needed.
2012-01-01
Background Real-time quantitative nucleic acid sequence-based amplification (QT-NASBA) is a sensitive method for detection of sub-microscopic gametocytaemia by measuring gametocyte-specific mRNA. Performing analysis on fresh whole blood samples is often not feasible in remote and resource-poor areas. Convenient methods for sample storage and transport are urgently needed. Methods Real-time QT-NASBA was performed on whole blood spiked with a dilution series of purified in-vitro cultivated gametocytes. The blood was either freshly processed or spotted on filter papers. Gametocyte detection sensitivity for QT-NASBA was determined and controlled by microscopy. Dried blood spot (DBS) samples were subjected to five different storage conditions and the loss of sensitivity over time was investigated. A formula to approximate the loss of Pfs25-mRNA due to different storage conditions and time was developed. Results Pfs25-mRNA was measured in time to positivity (TTP) and correlated well with the microscopic counts and the theoretical concentrations of the dilution series. TTP results constantly indicated higher amounts of RNA in filter paper samples extracted after 24 hours than in immediately extracted fresh blood. Among investigated storage conditions freezing at −20°C performed best with 98.7% of the Pfs25-mRNA still detectable at day 28 compared to fresh blood samples. After 92 days, the RNA detection rate was only slightly decreased to 92.9%. Samples stored at 37°C showed most decay with only 64.5% of Pfs25-mRNA detectable after one month. The calculated theoretical detection limit for 24 h-old DBS filter paper samples was 0.0095 (95% CI: 0.0025 to 0.0380) per μl. Conclusions The results suggest that the application of DBS filter papers for quantification of Plasmodium falciparum gametocytes with real-time QT-NASBA is practical and recommendable. This method proved sensitive enough for detection of sub-microscopic densities even after prolonged storage. Decay rates can be predicted for different storage conditions as well as durations. PMID:22545954
Luo, Wei; Davis, Geoff; Li, LiXia; Shriver, M Kathleen; Mei, Joanne; Styer, Linda M; Parker, Monica M; Smith, Amanda; Paz-Bailey, Gabriela; Ethridge, Steve; Wesolowski, Laura; Owen, S Michele; Masciotra, Silvina
2017-06-01
FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture. Published by Elsevier B.V.
Antunes, Marina Venzon; Raymundo, Suziane; de Oliveira, Vanessa; Staudt, Dilana Elisabeth; Gössling, Gustavo; Peteffi, Giovana Piva; Biazús, Jorge Villanova; Cavalheiro, José Antônio; Tre-Hardy, Marie; Capron, Arnaud; Haufroid, Vincent; Wallemacq, Pierre; Schwartsmann, Gilberto; Linden, Rafael
2015-01-01
A LC-MSMS method for the simultaneous determination of tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen in dried blood spots samples was developed and validated. The method employs an ultrasound-assisted liquid extraction and a reversed phase separation in an Acquity(®) C18 column (150×2.1 mm, 1.7 µm). Mobile phase was a mixture of formic acid 0.1% (v/v) pH 2.7 and acetonitrile (gradient from 60:40 to 50:50, v/v). Total analytical run time was 8 min. Precision assays showed CV % lower than 10.75% and accuracy in the range 94.5 to 110.3%. Mean analytes recoveries from DBS ranged from 40% to 92%. The method was successfully applied to 91 paired clinical DBS and plasma samples. Dried blood spots concentrations were highly correlated to plasma, with rs>0.83 (P<0.01). Median estimated plasma concentrations after hematocrit and partition factor adjustment were: TAM 123.3 ng mL(-1); NDT 267.9 ng mL(-1), EDF 10.0 ng mL(-1) and HTF 1.3 ng mL(-1,) representing in average 98 to 104% of the actually measured concentrations. The DBS method was able to identify 96% of patients with plasma EDF concentrations below the clinical threshold related to better prognosis (5.9 ng mL(-1)). The procedure has adequate analytical performance and can be an efficient tool to optimize adjuvant breast cancer treatment, especially in resource limited settings. Copyright © 2014 Elsevier B.V. All rights reserved.
Jager, Nynke Gl; Rosing, Hilde; Schellens, Jan Hm; Beijnen, Jos H
2014-01-01
We developed an HPLC-MS/MS method to quantify tamoxifen (2.5-250 ng/ml) and its metabolite (Z)-endoxifen (0.5-50 ng/ml) in dried blood spots. Extraction recovery of both analytes from Whatman DMPK-A cards was 100% and consistent over time, however, recovery of (Z)-endoxifen from Whatman 903 cards was incomplete and increased upon storage. When SDS, a constituent of the DMPK-A coating, was present during the extraction, recovery improved. The method using DMPK-A cards was validated using bioanalytical guidelines. Additionally, influence of haematocrit (0.29-0.48 L/L), spot volume (20-50 µl) and homogeneity was within limits and both analytes were stable in DBS for at least 4 months. The method for the quantification of tamoxifen and (Z)-endoxifen in DBS collected on DMPK-A cards was successfully validated.
Viljoen, Johannes; Gampini, Sandrine; Danaviah, Sivapragashini; Valéa, Diane; Pillay, Sureshnee; Kania, Dramane; Méda, Nicolas; Newell, Marie-Louise; Van de Perre, Philippe; Rouet, François
2010-11-01
There is an urgent need to assess the accuracy/feasibility of using dried blood spots (DBS) for monitoring of HIV-1 viral load in resource-limited settings. A total of 892 DBS from HIV-1-positive pregnant women and their neonates enrolled in the Kesho Bora prevention of mother-to-child transmission trial conducted in Durban (South Africa) and Bobo-Dioulasso (Burkina Faso) between May 2005 and July 2008 were tested for HIV-1 RNA. The combination Nuclisens extraction method (BioMérieux)/Generic HIV Viral Load assay (Biocentric) was performed using one DBS (in Durban) versus 2 DBS (in Bobo-Dioulasso) on 2 distinct open real-time polymerase chain reaction instruments. DBS HIV-1 RNA results were compared with plasma HIV-1 RNA and HIV serology results used as the gold standards. The limits of detection of assays on DBS were 3100 and 1550 copies per milliliter in Durban and Bobo-Dioulasso, respectively. DBS HIV-1 RNA values correlated significantly with plasma levels (n = 327; R = 0.7351) and were uniformly distributed according to duration of DBS storage at -20°C (median duration, 280 days). For early infant diagnosis, the sensitivity and specificity were 100% (95% confidence interval: 97.2 to 100.0 and 96.5 to 100.0, respectively). HIV-1 viral load kinetics in DNase-pretreated DBS were similar to those obtained in plasma specimens among 13 patients receiving antiretroviral treatment. HIV-1 RNA findings from serial infant DBS collected prospectively (n = 164) showed 100% concordance with HIV serology at 18 months of life. Our findings strongly advocate the implementation of DBS HIV-1 RNA testing in remote areas from low-income and middle-income countries.
2013-01-01
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095
Zakaria, Rosita; Allen, Katrina J; Koplin, Jennifer J; Roche, Peter; Greaves, Ronda F
2016-12-01
Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; "blood spot" and "mass spectrometry"; while excluding "newborn"; and "neonate". In addition, databases were restricted to English language and human specific. There was no time period limit applied. As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required.
Kong, Sing Teang; Lim, Shih-Hui; Lee, Wee Beng; Kumar, Pasikanthi Kishore; Wang, Hwee Yi Stella; Ng, Yan Lam Shannon; Wong, Pei Shieen; Ho, Paul C.
2014-01-01
To facilitate therapeutic monitoring of antiepileptic drugs (AEDs) by healthcare professionals for patients with epilepsy (PWE), we applied a GC-MS assay to measure three AEDs: carbamazepine (CBZ), phenytoin (PHT) and valproic acid (VPA) levels concurrently in one dried blood spot (DBS), and validated the DBS-measured levels to their plasma levels. 169 PWE on either mono- or polytherapy of CBZ, PHT or/and VPA were included. One DBS, containing ∼15 µL of blood, was acquired for the simultaneous measurement of the drug levels using GC-MS. Simple Deming regressions were performed to correlate the DBS levels with the plasma levels determined by the conventional immunoturbimetric assay in clinical practice. Statistical analyses of the results were done using MedCalc Version 12.6.1.0 and SPSS 21. DBS concentrations (Cdbs) were well-correlated to the plasma concentrations (Cplasma): r = 0.8381, 0.9305 and 0.8531 for CBZ, PHT and VPA respectively, The conversion formulas from Cdbs to plasma concentrations were [0.89×CdbsCBZ+1.00]µg/mL, [1.11×CdbsPHT−1.00]µg/mL and [0.92×CdbsVPA+12.48]µg/mL respectively. Inclusion of the red blood cells (RBC)/plasma partition ratio (K) and the individual hematocrit levels in the estimation of the theoretical Cplasma from Cdbs of PHT and VPA further improved the identity between the observed and the estimated theoretical Cplasma. Bland-Altman plots indicated that the theoretical and observed Cplasma of PHT and VPA agreed well, and >93.0% of concentrations was within 95% CI (±2SD); and similar agreement (1∶1) was also found between the observed Cdbs and Cplasma of CBZ. As the Cplasma of CBZ, PHT and VPA can be accurately estimated from their Cdbs, DBS can therefore be used for drug monitoring in PWE on any of these AEDs. PMID:25255292
Jimmerson, Leah C.; Zheng, Jia-Hua; Bushman, Lane R.; MacBrayne, Christine E.; Anderson, Peter L.; Kiser, Jennifer J.
2014-01-01
Efficient, inexpensive and sensitive assays for the measurement of drugs are of interest for pharmacokinetic and pharmacodynamics (PK-PD) analysis. Dried blood spots (DBS) are a unique bioanaltyical matrix with the potential to fulfill this interest for the measurement of numerous analytes. Here we describe the development and validation of a reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of ribavirin (RBV) in DBS. A 3mm punch from spotted and dried whole blood was extracted in methanol utilizing isotopically labeled internal standard for LC-MS/MS analysis. Validation was performed over a range of 0.05 μg/mL to 10.0 μg/mL and the method was shown to be precise (coefficient of variation ≤ 15%) and accurate (within ±15% of control). These acceptance criteria were met for hematocrit ranges of 20-54%, for center versus edge punches and for spot volumes from 10-60 μL. RBV was stable for up to 140 days at room temperature and −20°C as well as for three freeze/thaw cycles. Correlation of RBV in DBS versus in plasma yielded r2 ≥ 0.98 demonstrating that DBS can be used as an alternative to plasma for PK-PD studies in human subjects. PMID:24291608
Sadler Simões, Susana; Castañera Ajenjo, Antonio; Dias, Mário João
2018-01-05
A method for the simultaneous determination of 11 illicit drugs, using the dried blood spot (DBS) sampling technique combined with the UPLC-MS/MS technology was developed to study its applicability within the forensic toxicology. The DBS samples, prepared from a blood volume of 50μL and using the Whatman® BFC 180 bloodstain cards, were extracted with a methanol/acetonitrile mixture. The chromatographic separation was performed using an Acquity UPLC ® HSS T3 column (100mm×2.1mm, 1.8μm) and an acetonitrile/2mM ammonium formate (0.1% formic acid) gradient. The detection was accomplished with a TQ Detector, operating in the ESI+ and MRM modes. The method was validated in terms of selectivity, matrix effect, extraction recovery (42%-91%), carryover, LOD and LOQ (0.5-1ng/mL and 1-5ng/mL, respectively), linearity (LOQ to 500ng/mL), intraday and interday precision (3.8-14% and 5.3-13%, respectively), accuracy (-9.3% to 7.9%) and dilution integrity. An eight months stability study at room temperature, 2-8°C and -10°C, was also performed, with the best results obtained at -10°C. The procedure was applied to 64 real samples (92 positive results for substances included in this study). The results were compared with the methodologies routinely applied in the laboratory and the statistical analysis allowed to establish an acceptable correlation. This study permitted to determine that the DBS can represent an alternative or a complement to conventional analytical and sampling techniques, responding to some of the present issues concerning the different forensic toxicology applications. Copyright © 2017 Elsevier B.V. All rights reserved.
Botkin, Jeffrey R; Rothwell, Erin; Anderson, Rebecca A; Rose, Nancy C; Dolan, Siobhan M; Kuppermann, Miriam; Stark, Louisa A; Goldenberg, Aaron; Wong, Bob
2016-06-01
Research clearly indicates that current approaches to newborn blood spot screening (NBS) education are ineffective. Incorporating NBS education into prenatal care is broadly supported by lay and professional opinion. To determine the efficacy and effect of prenatal education about newborn screening and use of residual dried blood spots (DBS) in research on parental knowledge, attitudes, and behaviors. A randomized clinical trial of prenatal educational interventions, with outcomes measured by survey at 2 to 4 weeks postpartum. Participants were recruited from obstetric clinics in Salt Lake City, Utah; San Francisco, California; and the Bronx, New York. Eligible women were English- or Spanish-speaking adults and did not have a high-risk pregnancy. A total of 901 women were enrolled. Participants who completed the follow-up survey included 212 women in the usual care group (70% retention), 231 in the NBS group (77% retention), and 221 women in the NBS + DBS group (75% retention). Those who completed the survey were similar across the 3 groups with respect to age, ethnicity, race, education, marital status, income, obstetric history, and language. Participants were randomized into 1 of 3 groups: usual care (n = 305), those viewing an NBS movie and brochure (n = 300), and those viewing both the NBS and DBS movies and brochures (n = 296). Two to four weeks postpartum, women completed a 91-item survey by telephone, addressing knowledge, attitudes, and behavior with respect to opting out of NBS or DBS for their child. A total of 901 women (mean age, 31 years) were randomized and 664 completed the follow-up survey. The total correct responses on the knowledge instrument in regard to NBS were 69% in the usual care group, 79% in the NBS group, and 75% in the NBS + DBS group, a significant between-group difference (P < .05). Although all groups showed strong support for NBS, the percentage of women who were "very supportive" was highest in the NBS group (94%), followed by the NBS + DBS group (86%) and was lowest in the usual care group (73%) (P < .001). The interventions were not associated with decisions to decline newborn screening or withdraw residual DBS. Nine women stated that they had declined NBS (all the usual care group; P < .001). With respect to DBS, 5 participants indicated that they contacted the health department to have their child's sample withdrawn after testing: 3 in the NBS + DBS group and 2 in the usual care group (P = .25). Educational interventions can be implemented in the prenatal clinic, using multimedia tools and electronic platforms. Prenatal education is effective in increasing postnatal knowledge and support for these programs. These results are relevant to other contexts in which residual clinical specimens and data are used for research purposes. clinicaltrials.gov Identifier: NCT02676245.
Koontz, Deborah; Baecher, Kirsten; Kobrynski, Lisa; Nikolova, Stanimila; Gallagher, Margaret
2015-01-01
The 22q11.2 deletion syndrome is one of the most common deletion syndromes in newborns. Some affected newborns may be diagnosed shortly after birth because of the presence of heart defects, palatal defects, or severe immune deficiencies. However, diagnosis is often delayed in patients presenting with other associated conditions that would benefit from early recognition and treatment, such as speech delays, learning difficulties, and schizophrenia. Fluorescence in situ hybridization (FISH) is the gold standard for deletion detection, but it is costly and time consuming and requires a whole blood specimen. Our goal was to develop a suitable assay for population-based screening of easily collectible specimens, such as buccal swabs and dried blood spots (DBS). We designed a pyrosequencing assay and validated it using DNA from FISH–confirmed 22q11 deletion syndrome patients and normal controls. We tested DBS from nine patients and paired buccal cell and venous blood specimens from 20 patients. Results were 100% concordant with FISH assay results. DNA samples from normal controls (n = 180 cell lines, n = 15 DBS, and n = 88 buccal specimens) were negative for the deletion. Limiting dilution experiments demonstrated that accurate results could be obtained from as little as 1 ng of DNA. This method represents a reliable and low-cost alternative for detection of the common 22q11.2 microdeletions and can be adapted to high-throughput population screening. PMID:24973633
Reevaluating Muscle Biopsies in the Diagnosis of Pompe Disease: A Corroborative Report.
Genge, Angela; Campbell, Natasha
2016-07-01
Previous reports suggest that although a diagnostic muscle biopsy can confirm the presence of Pompe disease, the absence of a definitive biopsy result does not rule out the diagnosis. In this study, we reviewed patients with a limb-girdle syndrome who demonstrated nonspecific abnormalities of muscle, without evidence of the classical changes of acid maltase deficiency. These patients were rescreened for Pompe disease using dried blood spot (DBS) testing. Twenty-seven patients provided blood samples for the DBS test. Four patients underwent subsequent genetic testing. Genetic analysis demonstrated that one patient tested positive for Pompe disease and one patient had one copy of a pathogenic variant. In conclusion, the ability of a diagnostic muscle biopsy to definitively rule out the presence of Pompe disease is limited. There is a role for a screening DBS in all patients presenting with a limb-girdle syndrome without a clear diagnosis.
The performance of five different dried blood spot cards for the analysis of six immunosuppressants.
Koster, Remco A; Botma, Rixt; Greijdanus, Ben; Uges, Donald R A; Kosterink, Jos G W; Touw, Daan J; Alffenaar, Jan-Willem C
2015-01-01
The relation between hematocrit, substance concentration, extraction recovery and spot formation of tacrolimus, sirolimus, everolimus, ascomycin, temsirolimus and cyclosporin A was investigated for Whatman 31 ET CHR, Whatman FTA DMPK-C, Whatman 903, Perkin Elmer 226 and Agilent Bond Elut DMS DBS cards. We found that all DBS cards showed the same hematocrit and concentration-dependent recovery patterns for sirolimus, everolimus and temsirolimus. At high concentrations, the total hematocrit effects were much more pronounced than at low concentrations for tacrolimus, sirolimus, everolimus, ascomycin and temsirolimus. The tested card types showed differences in performance, especially at extreme concentrations and hematocrit values. It may be useful to investigate the performance of different types of DBS cards prior to analytical method validation.
A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.
Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal
2015-01-01
Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.
Schauer, Amanda P; Sykes, Craig; Cottrell, Mackenzie L; Prince, Heather; Kashuba, Angela D M
2018-02-05
The ability to monitor adherence to antiretroviral therapy is critical for the interpretation of outcomes from clinical studies of HIV, and for optimizing patient care. The antiretrovirals tenofovir (TFV), emtricitabine (FTC), and lamivudine (3TC) are commonly included in drug regimens for HIV prevention and treatment. The active form of the drugs tenofovir diphosphate (TFVdp), emtricitabine triphosphate (FTCtp), and lamivudine triphosphate (3TCtp) are found intracellularly in erythrocytes and peripheral blood mononuclear cells (PBMCs). The ability to collect and analyze dried blood spot (DBS) samples is an attractive alternative to PBMC sampling in many resource limited settings. We developed and validated an assay to quantify all three intracellular metabolites over the range of 100-25000 fmol/sample. This assay utilizes a simple protein precipitation/liquid-liquid extraction of a single 3-mm DBS punch (from a Whatman 903 Protein Saver card) with isotopically labeled 13 C 5 -TFVdp included as the internal standard. Following extraction, samples are analyzed by anion exchange chromatography on a Thermo Biobasic AX 5μm column with detection by electrospray ionization in the positive mode on a AB Sciex API-5000 triple quadrupole mass spectrometer with a total run time of 8min. The assay was linear over the entire range (R 2 >0.996). The assay was accurate (inter-assay%bias within ±3.0%) and precise (inter-assay % CV≤9.8%). The assay was also reproducible from multiple punches within a spot as well as punches from separate blood spots. Stability was established at room temperature for 3days, and at -80°C for up to 63days. Clinical samples were analyzed from subjects on Truvada ® , Stribild ® , Descovy ® , and Triumeq ® regimens and intracellular metabolites were detected in all samples as expected, indicating the assay performs well for all current formulations of TFV, FTC, and 3TC. Copyright © 2017 Elsevier B.V. All rights reserved.
Hahn, Roberta Z; Arnhold, Priscila C; Andriguetti, Natália B; Schneider, Anelise; Klück, Helena M; Dos Reis, Simone L; Bastiani, Marcos Frank; Kael, Igor; da Silva, Anne Caroline Cezimbra; Schwartsmann, Gilberto; Antunes, Marina V; Linden, Rafael
2018-02-20
Irinotecan (IRI) is an antineoplastic drug widely used for the treatment of colorectal and advanced pancreatic cancer. Despite its clinical utility, the clinical use of IRI is associated with potentially severe hematopoietic and gastrointestinal toxicities. The quantification of IRI and its active metabolite SN-38 in dried blood spots (DBS) may be an alternative to individualize the drug dose through a minimally invasive and easy collection method. The aim of this study was to develop and validate a simple and fast HPLC-FL assay for simultaneous IRI and SN-38 measurement in DBS, with adequate analytical performance for clinical use. The method employs liquid extraction of one 8mm disk of whole blood, followed by separation in a reversed phase Eclipse Plus C8 column (150×4.6mm, 5μm). Detection was performed with a fluorescence detector, with excitation wavelength of 370 and emission of 420 for IRI and 540nm for SN-38 and internal standard (camptothecin). Total analytical run time was 17min. Mobile phase was a mixture of 0.1M phosphate buffer pH 4.0 and acetonitrile (80:20, v/v), at 1mLmin -1 . The assay was linear in the range 10-3,000ngmL -1 and from 0.5 to 300ngmL -1 for IRI and SN-38, respectively. Precision assays presented CV% of 2.71-5.65 and 2.15-10.07 for IRI and SN-38, respectively, and accuracy in the range of 94.26-100.93 and 94.24-99.33%. IRI and SN-38 were stable at 25 and 42°C for 14days in DBS samples. The method was applied to DBS samples obtained from fingerpicks from 19 volunteers receiving IRI in single or combined chemotherapy regimens, collected 1 and 24h after beginning of the infusion. The estimated plasma concentration of IRI and SN-38 in sample collected 1h after star of infusion had 16 of 19 values within the ±20% range of the measured plasma concentrations. On the other hand, predictions of IRI and SN-38 plasma concentrations from DBS measurements obtained 24h after the beginning of the infusion were poor. AUC of IRI that was calculated using plasma and DBS-estimated concentrations, with a high correlation (r=0.918). The method presented suitable characteristics for the clinical use. However, translation of IRI and SN-38 DBS to plasma concentrations is challenging due to the compound's variable plasma/blood partition. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Chunyan; Zhang, Wenyan; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2012-05-01
The analysis by electrospray-ionization tandem mass spectrometry of amino acids with butyl esterification and isotopically labeled internal standard is routine in newborn screening laboratories worldwide. In the present study, we established a direct analysis method of higher accuracy that uses a non-deuterated internal standard. The automatic sampler and the pump of an LC apparatus were used to inject sample and mobile phase to MS, but no LC column was needed. The dry blood spot (DBS) material was prepared at levels of low, medium and high concentration; the running time was 1 min. In parallel to the new procedure, we applied the established method to analyze nine amino acids on DBS of healthy newborns and phenylketonuria newborns. The newly proposed method of product ion confirmation scan along with multiple reaction monitoring resulted in a very accurate identification of each amino acid. Our innovative protocol had high sensitivity and specificity in the analysis of cases of suspected metabolic diseases.
Saussereau, E; Lacroix, C; Gaulier, J M; Goulle, J P
2012-02-15
A novel approach has been developed for the illicit drugs quantitative determination using dried blood spots (DBS) on filter paper. The illicit drugs tested were opiates (morphine and its 3- and 6-glucuronide metabolites, codeine, 6-monoacetylmorphine), cocainics (ecgonine methylester, benzoylecgonine, cocaine, cocaethylene) and amphetamines (amphetamine, methamphetamine, MDA, MDMA, MDEA). The described method, requiring a small blood volume, is based on high performance liquid chromatography coupled to tandem mass spectrometry using on-line extraction. A Whatman card 903 was spotted with 30μL of whole blood and left overnight to dry at room temperature. A 3-mm diameter disk was removed using a manual punch, suspended in 150μL of water for 10min with ultrasonication, and then 100μL was injected in the on-line LC-MS/MS system. An Oasis HLB was used as an extraction column and a C18 Atlantis as an analytical column. The chromatographic cycle was performed with 20mM ammonium formate buffer (pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 16min. Detection was performed in positive electrospray ionization mode (ESI+) with a Quattro Micro (Waters). Recoveries of all analytes were up to 80%. DBS were stored in duplicate at 4°C and -20°C for up to 6 months. Illicit drugs seemed to be much more stabled at -20°C. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating authentic samples; significant correlations were obtained. This DBS assay has potential as rapid, sensitive and inexpensive option for the illicit drugs determination in small blood volumes, which seems of great interest in suspected cases of driving under the influence of drugs. Copyright © 2011 Elsevier B.V. All rights reserved.
Cvan Trobec, Katja; Trontelj, Jurij; Springer, Jochen; Lainscak, Mitja; Kerec Kos, Mojca
2014-05-01
Dried blood spot (DBS) sampling represents a suitable method for pharmacokinetic studies in rats, particularly if serial sampling is needed. To study the pharmacokinetics of drugs in a rat heart failure (HF) model, we developed and validated a method for the simultaneous determination of bisoprolol, ramiprilat, propranolol and midazolam in DBS samples. Bisoprolol and ramipril are widely used in the treatment of HF, and midazolam and propranolol are markers of hepatic metabolism, which can be altered in HF. A 20μL sample of rat blood was pipetted onto Whatman 903 Protein Saver Card and allowed to dry. The whole spot was excised and 300μL of solvent (methanol with 10% ultrapure water and 0.1% formic acid) was added. After mixing and incubating the sample in an ultrasonic bath, a mixture of isotopically labeled internal standards was added. After centrifugation, the extracts were cleaned on an Ostro™ plate and analyzed using liquid chromatography-tandem mass spectroscopy. The method was successfully validated. No significant interference was observed in the retention times of analytes or internal standards. The intraday and interday accuracy and precision were within a ±15% interval. The method was linear in the range 5-250μg/L and the lower limit of quantification was 5μg/L for all four analytes. The absolute matrix effect ranged from 98.7% for midazolam to 121% for ramiprilat. The recovery was lowest for ramiprilat and highest for propranolol. Samples were stable at all tested temperatures. The method has been used successfully in a real-time pharmacokinetic study in rats. Copyright © 2014 Elsevier B.V. All rights reserved.
Perera, Rushini S.; Ding, Xavier C.; Tully, Frank; Oliver, James; Bright, Nigel; Bell, David; Chiodini, Peter L.; Gonzalez, Iveth J.; Polley, Spencer D.
2017-01-01
Background Accurate and efficient detection of sub-microscopic malaria infections is crucial for enabling rapid treatment and interruption of transmission. Commercially available malaria LAMP kits have excellent diagnostic performance, though throughput is limited by the need to prepare samples individually. Here, we evaluate the clinical performance of a newly developed high throughput (HTP) sample processing system for use in conjunction with the Eiken malaria LAMP kit. Methods The HTP system utilised dried blood spots (DBS) and liquid whole blood (WB), with parallel sample processing of 94 samples per run. The system was evaluated using 699 samples of known infection status pre-determined by gold standard nested PCR. Results The sensitivity and specificity of WB-HTP-LAMP was 98.6% (95% CI, 95.7–100), and 99.7% (95% CI, 99.2–100); sensitivity of DBS-HTP-LAMP was 97.1% (95% CI, 93.1–100), and specificity 100% against PCR. At parasite densities greater or equal to 2 parasites/μL, WB and DBS HTP-LAMP showed 100% sensitivity and specificity against PCR. At densities less than 2 p/μL, WB-HTP-LAMP sensitivity was 88.9% (95% CI, 77.1–100) and specificity was 99.7% (95% CI, 99.2–100); sensitivity and specificity of DBS-HTP-LAMP was 77.8% (95% CI, 54.3–99.5) and 100% respectively. Conclusions The HTP-LAMP system is a highly sensitive diagnostic test, with the potential to allow large scale population screening in malaria elimination campaigns. PMID:28166235
Pilot proficiency testing study for second tier congenital adrenal hyperplasia newborn screening.
De Jesús, Víctor R; Simms, David A; Schiffer, Jarad; Kennedy, Meredith; Mei, Joanne V; Hannon, W Harry
2010-11-11
Congenital adrenal hyperplasia (CAH) is caused by inherited defects in steroid biosynthesis. The Newborn Screening Quality Assurance Program (NSQAP) initiated a pilot, dried-blood spot (DBS)-based proficiency testing program designed to investigate materials and laboratory performance for second tier CAH screening by tandem mass spectrometry (MS/MS). The ratio of 17-α-hydroxyprogesterone (17-OHP), androstenedione (4-AD) and cortisol is used as an indicator of CAH in laboratory protocols for second tier analysis of DBS specimens. DBS prepared by NSQAP contained a range of steroid concentrations resulting in different clinical ratios. Laboratories received blind-coded DBS specimens and reported results to NSQAP for evaluation. Quantitative values reported by participants for 17-OHP, 4-AD, and cortisol, reflected small differences in their analytical methods. Average quantitative values for 17-OHP increased from 81% to 107% recovery over the 3.5-year period; cortisol recoveries increased from 61.9% to 89.5%; and 4-AD recoveries decreased from 184% to 68%. Laboratory participation in the CAH second tier proficiency testing program has resulted in improved analyte recoveries and enhanced sample preparation methodologies. NSQAP services for the second tier CAH analysis in DBS demonstrate the need for surveillance to ensure harmonization and continuous improvements, and to achieve sustained high-performance of newborn screening laboratories worldwide. Published by Elsevier B.V.
Presymptomatic Diagnosis of Spinal Muscular Atrophy Through Newborn Screening.
Chien, Yin-Hsiu; Chiang, Shu-Chuan; Weng, Wen-Chin; Lee, Ni-Chung; Lin, Ching-Jie; Hsieh, Wu-Shiun; Lee, Wang-Tso; Jong, Yuh-Jyh; Ko, Tsang-Ming; Hwu, Wuh-Liang
2017-11-01
To demonstrate the feasibility of presymptomatic diagnosis of spinal muscular atrophy (SMA) through newborn screening (NBS). We performed a screening trial to assess all newborns who underwent routine newborn metabolic screening at the National Taiwan University Hospital newborn screening center between November 2014 and September 2016. A real-time polymerase chain reaction (RT-PCR) genotyping assay for the SMN1/SMN2 intron 7 c.888+100A/G polymorphism was performed to detect homozygous SMN1 deletion using dried blood spot (DBS) samples. Then the exon 7 c.840C>T mutation and SMN2 copy number were determined by both droplet digital PCR (ddPCR) using the original screening DBS and multiplex ligation-dependent probe amplification (MLPA) using a whole blood sample. Of the 120 267 newborns, 15 tested positive according to the RT-PCR assay. The DBS ddPCR assay excluded 8 false-positives, and the other 7 patients were confirmed by the MLPA assay. Inclusion of the second-tier DBS ddPCR screening assay resulted in a positive prediction value of 100%. The incidence of SMA was 1 in 17 181 (95% CI, 1 in 8323 to 1 in 35 468). Two of the 3 patients with 2 copies of SMN2 and all 4 patients with 3 or 4 copies of SMN2 were asymptomatic at the time of diagnosis. Five of the 8 false-positives were caused by intragenic recombination between SMN1 and SMN2. Newborn screening can detect patients affected by SMA before symptom onset and enable early therapeutic intervention. A combination of a RT-PCR and a second-tier ddPCR can accurately diagnose SMA from DBS samples with no false-positives. ClinicalTrials.gov NCT02123186. Copyright © 2017 Elsevier Inc. All rights reserved.
Ar Rochmah, Mawaddah; Harahap, Nur Imma Fatimah; Niba, Emma Tabe Eko; Nakanishi, Kenta; Awano, Hiroyuki; Morioka, Ichiro; Iijima, Kazumoto; Saito, Toshio; Saito, Kayoko; Lai, Poh San; Takeshima, Yasuhiro; Takeuchi, Atsuko; Bouike, Yoshihiro; Okamoto, Maya; Nishio, Hisahide; Shinohara, Masakazu
2017-10-01
Spinal muscular atrophy (SMA) is a common neuromuscular disorder caused by mutations in SMN1. More than 95% of SMA patients carry homozygous SMN1 deletion. SMA is the leading genetic cause of infant death, and has been considered an incurable disease. However, a recent clinical trial with an antisense oligonucleotide drug has shown encouraging clinical efficacy. Thus, early and accurate detection of SMN1 deletion may improve prognosis of many infantile SMA patients. A total of 88 DNA samples (37 SMA patients, 12 carriers and 39 controls) from dried blood spots (DBS) on filter paper were analyzed. All participants had previously been screened for SMN genes by PCR restriction fragment length polymorphism (PCR-RFLP) using DNA extracted from freshly collected blood. DNA was extracted from DBS that had been stored at room temperature (20-25°C) for 1week to 5years. To ensure sufficient quality and quantity of DNA samples, target sequences were pre-amplified by conventional PCR. Real-time modified competitive oligonucleotide priming-PCR (mCOP-PCR) with the pre-amplified PCR products was performed for the gene-specific amplification of SMN1 and SMN2 exon 7. Compared with PCR-RFLP using DNA from freshly collected blood, results from real-time mCOP-PCR using DBS-DNA for detection of SMN1 exon 7 deletion showed a sensitivity of 1.00 (CI [0.87, 1.00])] and specificity of 1.00 (CI [0.90, 1.00]), respectively. We combined DNA extraction from DBS on filter paper, pre-amplification of target DNA, and real-time mCOP-PCR to specifically detect SMN1 and SMN2 genes, thereby establishing a rapid, accurate, and high-throughput system for detecting SMN1-deletion with practical applications for newborn screening. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
Koontz, Deborah; Baecher, Kirsten; Kobrynski, Lisa; Nikolova, Stanimila; Gallagher, Margaret
2014-09-01
The 22q11.2 deletion syndrome is one of the most common deletion syndromes in newborns. Some affected newborns may be diagnosed shortly after birth because of the presence of heart defects, palatal defects, or severe immune deficiencies. However, diagnosis is often delayed in patients presenting with other associated conditions that would benefit from early recognition and treatment, such as speech delays, learning difficulties, and schizophrenia. Fluorescence in situ hybridization (FISH) is the gold standard for deletion detection, but it is costly and time consuming and requires a whole blood specimen. Our goal was to develop a suitable assay for population-based screening of easily collectible specimens, such as buccal swabs and dried blood spots (DBS). We designed a pyrosequencing assay and validated it using DNA from FISH-confirmed 22q11 deletion syndrome patients and normal controls. We tested DBS from nine patients and paired buccal cell and venous blood specimens from 20 patients. Results were 100% concordant with FISH assay results. DNA samples from normal controls (n = 180 cell lines, n = 15 DBS, and n = 88 buccal specimens) were negative for the deletion. Limiting dilution experiments demonstrated that accurate results could be obtained from as little as 1 ng of DNA. This method represents a reliable and low-cost alternative for detection of the common 22q11.2 microdeletions and can be adapted to high-throughput population screening. Copyright © 2014 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
A microsphere-based assay for mutation analysis of the biotinidase gene using dried blood spots
Lindau-Shepard, Barbara; Janik, David K.; Pass, Kenneth A.
2012-01-01
Biotinidase deficiency is an autosomal recessive syndrome caused by defects in the biotinidase gene, the product of which affects biotin metabolism. Newborn screening (NBS) for biotinidase deficiency can identify affected infants prior to onset of symptoms; biotin supplementation can resolve or prevent the clinical features. In NBS, dry blood spots (DBS) are usually tested for biotinidase enzyme activity by colorimetric analysis. By taking advantage of the multiplexing capabilities of the Luminex platform, we have developed a microsphere-based array genotyping method for the simultaneous detection of six disease causing mutations in the biotinidase gene, thereby permitting a second tier of molecular analysis. Genomic DNA was extracted from 3.2 mm DBS. Biotinidase gene sequences, containing the mutations of interest, were amplified by multiplexed polymerase chain reaction, followed by multiplexed allele-specific primer extension using universally tagged genotyping primers. The products were then hybridized to anti-tag carrying xTAG microspheres and detected on the Luminex platform. Genotypes were verified by sequencing. Genotyping results of 22 known biotinidase deficient samples by our xTAG biotinidase assay was in concordance with the results obtained from DNA sequencing, for all 6 mutations used in our panel. These results indicate that genotyping by an xTAG microsphere-based array is accurate, flexible, and can be adapted for high-throughput. Since NBS for biotinidase deficiency is by enzymatic assay, less than optimal quality of the DBS itself can compromise enzyme activity, while the DNA from these samples mostly remains unaffected. This assay warrants evaluation as a viable complement to the biotinidase semi-quantitative colorimetric assay. PMID:27625817
Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter
2016-01-01
Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263
da Silva, Anne Caroline Cezimbra; Raasch, Juliana Raquel; Vargas, Tainara Gomes; Peteffi, Giovana Piva; Hahn, Roberta Zilles; Antunes, Marina Venzon; Perassolo, Magda Susana; Linden, Rafael
2018-02-01
Therapeutic drug monitoring (TDM) of the widely prescribed antidepressant fluoxetine (FLU) is recommended in certain situations, such as occurrence of toxicity, inadequate response or suspect of poor adherence. Dried blood spot (DBS) sampling is an increasingly studied alternative for TDM, particularly for outpatients, due to its ease of collection and inherent stability. The aim of this study was to develop and validate an LC-MS/MS assay for the simultaneous quantification of FLU and norfluoxetine (NFLU) in DBS. The assay is based on a liquid extraction of single DBS with 8mm of diameter, using FLU-D6 as the internal standard, followed by reversed phase separation in an Accucore® C18 column (100×2.1mm, 2.6μm). Mobile phase was composed of water and acetonitrile (gradient from 80:20 to 50:50, v/v), both containing formic acid 0.1%. The assay was validated and applied to 30 patients under FLU pharmacotherapy. The assay was linear in the range 10-750ngmL -1 . Precision assays presented CV% of 3.13-9.61 and 3.54-7.99 for FLU and NFLU, respectively, and accuracy in the range of 97.98-110.44% and 100.25-105.8%. FLU and NFLU were stable at 25 and 45°C for 7days. The assay was evaluated in 30 patients under FLU treatment. Concentrations of both compounds were higher in DBS than in plasma, and the use of the multiplying factors 0.71 and 0.68 for FLU and NFLU, respectively, allowed acceptable estimation of plasma concentrations, with median prediction bias of -0.55 to 0.55% and mean differences of 0.4 to 2.2ngmL -1 . The presented data support the clinical use of DBS for therapeutic drug monitoring of FLU. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Tran, C; Yazdanpanah, M; Kyriakopoulou, L; Levandovskiy, V; Zahid, H; Naufer, A; Isbrandt, D; Schulze, A
2014-09-25
To develop an accurate stable isotope dilution assay for simultaneous quantification of creatine metabolites ornithine, arginine, creatine, creatinine, and guanidinoacetate in very small blood sample volumes to study creatine metabolism in mice. Liquid-chromatography (C18) tandem mass spectrometry with butylation was performed in positive ionization mode. Stable isotope dilution assay with external calibration was applied to three different specimen types, plasma, whole blood and dried blood spot (DBS). Analytical separation, sensitivity, accuracy, and linearity of the assay were adequate. The stable isotope dilution assay in plasma revealed no significant bias to gold standard methods for the respective analytes. Compared to plasma, we observed an overestimate of creatine and creatinine (2- to 5-fold and 1.2- to 2-fold, respectively) in whole-blood and DBS, and an underestimate of arginine (2.5-fold) in DBS. Validation of the assay in mouse models of creatine deficiency revealed plasma creatine metabolite pattern in good accordance with those observed in human GAMT and AGAT deficiency. Single dose intraperitoneal application of ornithine in wild-type mice lead to fast ornithine uptake (Tmax ≤ 10 min) and elimination (T1/2=24 min), and a decline of guanidinoacetate. The assay is fast and reliable to study creatine metabolism and pharmacokinetics in mouse models of creatine deficiency. Copyright © 2014 Elsevier B.V. All rights reserved.
Membrane materials for storing biological samples intended for comparative nanotoxicological testing
NASA Astrophysics Data System (ADS)
Metelkin, A.; Kuznetsov, D.; Kolesnikov, E.; Chuprunov, K.; Kondakov, S.; Osipov, A.; Samsonova, J.
2015-11-01
The study is aimed at identifying the samples of most promising membrane materials for storing dry specimens of biological fluids (Dried Blood Spots, DBS technology). Existing sampling systems using cellulose fiber filter paper have a number of drawbacks such as uneven distribution of the sample spot, dependence of the spot spreading area on the individual biosample properties, incomplete washing-off of the sample due to partially inconvertible sorption of blood components on cellulose fibers, etc. Samples of membrane materials based on cellulose, polymers and glass fiber with applied biosamples were studied using methods of scanning electron microscopy, FT-IR spectroscopy and surface-wetting measurement. It was discovered that cellulose-based membrane materials sorb components of biological fluids inside their structure, while membranes based on glass fiber display almost no interaction with the samples and biological fluid components dry to films in the membrane pores between the structural fibers. This characteristic, together with the fact that membrane materials based on glass fiber possess sufficient strength, high wetting properties and good storage capacity, attests them as promising material for dry samples of biological fluids storage systems.
Lin, Na; Ye, Jun; Qiu, Wenjuan; Han, Lianshu; Zhang, Huiwen; Gu, Xuefan
2013-01-01
Maple syrup urine disease (MSUD) is an inherited disorder caused by a deficiency of the mitochondrial branched-chain keto acid dehydrogenase complex. We investigated whether liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a more reliable and accurate method than MS/MS in the diagnosis and management of patients with MSUD in a Chinese population. A total of 370 dried blood spots (DBS) from healthy neonates, 44 DBS specimens from phenylketonuria neonates, and 38 DBS samples from 10 MSUD patients were retrospectively tested using the LC-MS/MS method. The results were compared with those obtained by the MS/MS method. The reference intervals of branched-chain amino acids (BCAAs) and alloiosleucine (Allo-Ile) were estimated for both sexes. In classic MSUD patients, Allo-Ile was markedly elevated (average of 136 μmol/L, which was significantly higher than the normal value, <5 μmol/L). The averages of BCAAs were also markedly elevated continually during the treatment. The application of the LC-MS/MS method in the measurement of Allo-Ile and BCAAs in DBS is more useful for diagnosing and managing classic MSUD than the MS/MS method.
Shanmugam, Vedapuri; Azarskova, Marianna; Nguyen, Shon; Hurlston, Mackenzie; Sabatier, Jennifer; Zhang, Guoqing; Osmanov, Saladin; Ellenberger, Dennis; Yang, Chunfu; Vitek, Charles; Liulchuk, Maria; Nizova, Natalya
2015-01-01
An accurate accessible test for early infant diagnosis (EID) is crucial for identifying HIV-infected infants and linking them to treatment. To improve EID services in Ukraine, dried blood spot (DBS) samples obtained from 237 HIV-exposed children (≤18 months of age) in six regions in Ukraine in 2012 to 2013 were tested with the AmpliSens DNA-HIV-FRT assay, the Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) HIV-1 Qual test, and the Abbott RealTime HIV-1 Qualitative assay. In comparison with the paired whole-blood results generated from AmpliSens testing at the oblast HIV reference laboratories in Ukraine, the sensitivity was 0.99 (95% confidence interval [CI], 0.95 to 1.00) for the AmpliSens and Roche CAP/CTM Qual assays and 0.96 (95% CI, 0.90 to 0.98) for the Abbott Qualitative assay. The specificity was 1.00 (95% CI, 0.97 to 1.00) for the AmpliSens and Abbott Qualitative assays and 0.99 (95% CI, 0.96 to 1.00) for the Roche CAP/CTM Qual assay. McNemar analysis indicated that the proportions of positive results for the tests were not significantly different (P > 0.05). Cohen's kappa (0.97 to 0.99) indicated almost perfect agreement among the three tests. These results indicated that the AmpliSens DBS and whole-blood tests performed equally well and were comparable to the two commercially available EID tests. More importantly, the performance characteristics of the AmpliSens DBS test meets the World Health Organization EID test requirements; implementing AmpliSens DBS testing might improve EID services in resource-limited settings. PMID:26447114
Bronze, Michelle; Wallis, Carole L.; Stuyver, Lieven; Steegen, Kim; Balinda, Sheila; Kityo, Cissy; Stevens, Wendy; Rinke de Wit, Tobias F.; Schuurman, Rob
2013-01-01
In resource-limited settings (RLS), reverse transcriptase (RT) inhibitors form the backbone of first-line treatment regimens. We have developed a simplified HIV-1 drug resistance genotyping assay targeting the region of RT harboring all major RT inhibitor resistance mutation positions, thus providing all relevant susceptibility data for first-line failures, coupled with minimal cost and labor. The assay comprises a one-step RT-PCR amplification reaction, followed by sequencing using one forward and one reverse primer, generating double-stranded coverage of RT amino acids (aa) 41 to 238. The assay was optimized for all major HIV-1 group M subtypes in plasma and dried blood spot (DBS) samples using a panel of reference viruses for HIV-1 subtypes A to D, F to H, and circulating recombinant form 01_AE (CRF01_AE) and applied to 212 clinical plasma samples and 25 DBS samples from HIV-1-infected individuals from Africa and Europe. The assay was subsequently transferred to Uganda and applied locally on clinical plasma samples. All major HIV-1 subtypes could be detected with an analytical sensitivity of 5.00E+3 RNA copies/ml for plasma and DBS. Application of the assay on 212 clinical samples from African subjects comprising subtypes A to D, F to H (rare), CRF01_AE, and CRF02_AG at a viral load (VL) range of 6.71E+2 to 1.00E+7 (median, 1.48E+5) RNA copies/ml was 94.8% (n = 201) successful. Application on clinical samples in Uganda demonstrated a comparable success rate. Genotyping of clinical DBS samples, all subtype C with a VL range of 1.02E+3 to 4.49E+5 (median, 1.42E+4) RNA copies/ml, was 84.0% successful. The described assay greatly reduces hands-on time and the costs required for genotyping and is ideal for use in RLS, as demonstrated in a reference laboratory in Uganda and its successful application on DBS samples. PMID:23536405
Martin, Paul; Cheung, S Y Amy; Yen, Mark; Han, David; Gillen, Michael
2016-01-01
The aims of the present study were to characterize the pharmacokinetics of fostamatinib in two phase I studies in healthy Japanese subjects after single- and multiple-dose administration, and to evaluate the utility of dried blood spot (DBS) sampling. In study A, 40 Japanese and 16 white subjects were randomized in a double-blind parallel group study consisting of seven cohorts, which received either placebo or a fostamatinib dose between 50 and 200 mg after single and multiple dosing. Pharmacokinetics of R406 (active metabolite of fostamatinib) in plasma and urine was assessed, and safety was intensively monitored. Study B was an open-label study that assessed fostamatinib 100 and 200 mg in 24 Japanese subjects. In addition to plasma and urine sampling (as for study A), pharmacokinetics was also assessed in blood. Mean maximum plasma concentration (C max) and area under total plasma concentration–time curve (AUC) increased with increasing dose in Japanese subjects. Steady state was achieved in 5–7 days for all doses. C max and AUC were both higher in Japanese subjects administered a 150-mg single dose than in white subjects. This difference was maintained for steady state exposure by day 10. Overall, R406 blood concentrations were consistent and ∼2.5-fold higher than in plasma. Minimal (<0.1 %) R406 was excreted in urine. Fostamatinib was well tolerated at all doses. Fostamatinib pharmacokinetics following single- and multiple-dose administration was approximately dose proportional at all doses ≤150 mg and greater than dose proportional at 200 mg in Japanese subjects. Japanese subjects administered fostamatinib 150 mg had higher exposure than white subjects. R406 could be measured in DBS samples and distributed into red blood cells, and DBS sampling was a useful method for assessing R406 pharmacokinetics.
Maritz, Jean; Preiser, Wolfgang; van Zyl, Gert U
2012-02-01
As antibody testing cannot confirm HIV-1 infection in children less than 18 months of age, diagnosis in these children depends on nucleic acid testing. The COBAS(®) AmpliPrep/COBAS(®) TaqMan(®) (CAP/CTM, Roche(®) Molecular Systems, Inc., Branchburg, NJ) HIV-1 Qualitative test is a total nucleic acid real-time PCR assay utilising whole EDTA blood or dried blood spots (DBS), which recently replaced the Roche(®) AMPLICOR(®) DNA test v1.5 (Amplicor) as the diagnostic HIV PCR assay in many South African laboratories. For the Amplicor assay, stringent diagnostic criteria were previously formulated for the local population, and a comparison reported the CAP/CTM's sensitivity at 99.7% and specificity at 100% for both sample types compared to these Amplicor criteria. To validate the assay prior to introduction in our laboratory and to define stringent diagnostic cut-off criteria. Whole EDTA blood samples from patients younger than 18 months sent for routine HIV-1 diagnosis were tested by Amplicor, and positive results were confirmed from DBS. CAP/CTM assays were subsequently performed from DBS. The CAP/CTM had a sensitivity of 98.8% and a specificity of 97.1%, but a positive predictive value (PPV) of only 78.7% compared to the Amplicor assay. Samples positive by CAP/CTM but negative by Amplicor displayed poor amplification curves compared to concordant positive samples. Upon re-testing those with sufficient material available by CAP/CTM, all showed negative results. The decreased PPV may either be due to false positive CAP/CTM results, or increased sensitivity compared to the Amplicor assay. Criteria were formulated for defining presumed false-positive results. Copyright © 2011 Elsevier B.V. All rights reserved.
Optimized DNA extraction from neonatal dried blood spots: application in methylome profiling
2014-01-01
Background Neonatal dried blood spots (DBS) represent an inexpensive method for long-term biobanking worldwide and are considered gold mines for research for several human diseases, including those of metabolic, infectious, genetic and epigenetic origin. However, the utility of DBS is restricted by the limited amount and quality of extractable biomolecules (including DNA), especially for genome wide profiling. Degradation of DNA in DBS often occurs during storage and extraction. Moreover, amplifying small quantities of DNA often leads to a bias in subsequent data, particularly in methylome profiles. Thus it is important to develop methodologies that maximize both the yield and quality of DNA from DBS for downstream analyses. Results Using combinations of in-house-derived and modified commercial extraction kits, we developed a robust and efficient protocol, compatible with methylome studies, many of which require stringent bisulfite conversion steps. Several parameters were tested in a step-wise manner, including blood extraction, cell lysis, protein digestion, and DNA precipitation, purification and elution. DNA quality was assessed based on spectrophotometric measurements, DNA detectability by PCR, and DNA integrity by gel electrophoresis and bioanalyzer analyses. Genome scale Infinium HumanMethylation450 and locus-specific pyrosequencing data generated using the refined DBS extraction protocol were of high quality, reproducible and consistent. Conclusions This study may prove useful to meet the increased demand for research on prenatal, particularly epigenetic, origins of human diseases and for newborn screening programs, all of which are often based on DNA extracted from DBS. PMID:24980254
Water-Soluble Dried Blood Spot in Protein Analysis: A Proof-of-Concept Study.
Rosting, Cecilie; Gjelstad, Astrid; Halvorsen, Trine Grønhaug
2015-08-04
In the present work human chorionic gonadotropin (hCG) was used as a model protein in a proof-of-concept study combining water-soluble dried blood spot (DBS) material in liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based protein analysis. A water-soluble material consisting of commercially available carboxymethyl cellulose (CMC) was evaluated as sampling material for this purpose. The material dissolved readily at physiological pH. Different sample preparation methods were evaluated, and in the final method, 15 μL of whole blood was deposited and dried on CMC before the whole spot was dissolved prior to cleanup by immunoaffinity extraction, tryptic digest, and preconcentration by solid-phase extraction (SPE). The results indicated complete dissolution of hCG from the spots, acceptable limit of detection (LOD) (0.1 IU/mL), linearity (R(2) = 0.959), accuracy (16%), and precision (≤22%). Long-term stability (45 days) of hCG in dried spots at reduced temperatures (≤8 °C) was also demonstrated. The analyte recovery was comparable to the commercially available nonsolvable cellulose material (FTA DMPK-C card).
Donzelli, Massimiliano; Derungs, Adrian; Serratore, Maria-Giovanna; Noppen, Christoph; Nezic, Lana; Krähenbühl, Stephan; Haschke, Manuel
2014-03-01
Phenotyping cocktails use a combination of cytochrome P450 (CYP)-specific probe drugs to simultaneously assess the activity of different CYP isoforms. To improve the clinical applicability of CYP phenotyping, the main objectives of this study were to develop a new cocktail based on probe drugs that are widely used in clinical practice and to test whether alternative sampling methods such as collection of dried blood spots (DBS) or saliva could be used to simplify the sampling process. In a randomized crossover study, a new combination of commercially available probe drugs (the Basel cocktail) was tested for simultaneous phenotyping of CYP1A2, CYP2B6, CYP2C9, CYP2C19, CYP2D6 and CYP3A4. Sixteen subjects received low doses of caffeine, efavirenz, losartan, omeprazole, metoprolol and midazolam in different combinations. All subjects were genotyped, and full pharmacokinetic profiles of the probe drugs and their main metabolites were determined in plasma, dried blood spots and saliva samples. The Basel cocktail was well tolerated, and bioequivalence tests showed no evidence of mutual interactions between the probe drugs. In plasma, single timepoint metabolic ratios at 2 h (for CYP2C19 and CYP3A4) or at 8 h (for the other isoforms) after dosing showed high correlations with corresponding area under the concentration-time curve (AUC) ratios (AUC0-24h parent/AUC0-24h metabolite) and are proposed as simple phenotyping metrics. Metabolic ratios in dried blood spots (for CYP1A2 and CYP2C19) or in saliva samples (for CYP1A2) were comparable to plasma ratios and offer the option of minimally invasive or non-invasive phenotyping of these isoforms. This new combination of phenotyping probe drugs can be used without mutual interactions. The proposed sampling timepoints have the potential to facilitate clinical application of phenotyping but require further validation in conditions of altered CYP activity. The use of DBS or saliva samples seems feasible for phenotyping of the selected CYP isoforms.
Medeiros, Jansen Fernandes; Almeida, Tatiana Amaral Pires; Silva, Lucyane Bastos Tavares; Rubio, Jose Miguel; Crainey, James Lee; Pessoa, Felipe Arley Costa; Luz, Sergio Luiz Bessa
2015-05-20
Mansonella ozzardi is a poorly understood human filarial parasite with a broad distribution throughout Latin America. Most of what is known about its parasitism has come from epidemiological studies that have estimated parasite incidence using light microscopy. Light microscopy can, however, miss lighter, submicroscopic, infections. In this study we have compared M. ozzardi incidence estimates made using light microscopy, with estimates made using PCR. 214 DNA extracts made from Large Volume Venous Blood Samples (LVVBS) were taken from volunteers from two study sites in the Rio Solimões region: Codajás [n = 109] and Tefé [n = 105] and were subsequently assayed for M. ozzardi parasitism using a diagnostic PCR (Mo-dPCR). Peripheral finger-prick blood samples were taken from the same individuals and used for microscopic examination. Finger-prick blood, taken from individuals from Tefé, was also used for the creation of FTAcard dried blood spots (DBS) that were subsequently subjected to Mo-dPCR. Overall M. ozzardi incidence estimates made with LVVBS PCRs were 1.8 times higher than those made using microscopy (44.9% [96/214] compared with 24.3% [52/214]) and 1.5 times higher than the PCR estimates made from FTAcard DBS (48/105 versus 31/105). PCR-based detection of FTAcard DBS proved 1.3 times more sensitive at diagnosing infections from peripheral blood samples than light microscopy did: detecting 24/105 compared with 31/105. PCR of LVVBS reported the fewest number of false negatives, detecting: 44 of 52 (84.6%) individuals diagnosed by microscopy; 27 of 31 (87.1%) of those diagnosed positive from DBSs and 17 out of 18 (94.4%) of those diagnosed as positive by both alternative methodologies. In this study, Mo-dPCR of LVVBS was by far the most sensitive method of detecting M. ozzardi infections and detected submicroscopic infections. Mo-dPCR FTAcard DBS also provided a more sensitive test for M. ozzardi diagnosis than light microscopy based diagnosis did and thus in settings where only finger-prick assays can be carried-out, it may be a more reliable method of detection. Most existing M. ozzardi incidence estimates, which are often based on light microscope diagnosis, are likely to dramatically underestimate true M. ozzardi parasitism incidence levels.
Kim, Borahm; Lee, Mi Na; Park, Hyung Doo; Kim, Jong Won; Chang, Yun Sil; Park, Won Soon; Lee, Soo Youn
2015-11-01
Conventional screening for congenital adrenal hyperplasia (CAH) using immunoassays generates a large number of false-positive results. A more specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been introduced to minimize unnecessary follow-ups. However, because of limited data on its use in the Korean population, LC-MS/MS has not yet been incorporated into newborn screening programs in this region. The present study aims to develop and validate an LC-MS/MS method for the simultaneous determination of seven steroids in dried blood spots (DBS) for CAH screening, and to define age-specific reference intervals in the Korean population. We developed and validated an LC-MS/MS method to determine the reference intervals of cortisol, 17-hydroxyprogesterone, 11-deoxycortisol, 21-deoxycortisol, androstenedione, corticosterone, and 11-deoxycorticosterone simultaneously in 453 DBS samples. The samples were from Korean subjects stratified by age group (78 full-term neonates, 76 premature neonates, 89 children, and 100 adults). The accuracy, precision, matrix effects, and extraction recovery were satisfactory for all the steroids at three concentrations; values of intra- and inter-day precision coefficients of variance, bias, and recovery were 0.7-7.7%, -1.5-9.8%, and 49.3-97.5%, respectively. The linearity range was 1-100 ng/mL for cortisol and 0.5-50 ng/mL for other steroids (R²>0.99). The reference intervals were in agreement with the previous reports. This LC-MS/MS method and the reference intervals validated in the Korean population can be successfully applied to analyze seven steroids in DBS for the diagnosis of CAH.
Dried Blood Spot Collection of Health Biomarkers to Maximize Participation in Population Studies
Ostler, Michael W.; Porter, James H.; Buxton, Orfeu M.
2014-01-01
Biomarkers are directly-measured biological indicators of disease, health, exposures, or other biological information. In population and social sciences, biomarkers need to be easy to obtain, transport, and analyze. Dried Blood Spots meet this need, and can be collected in the field with high response rates. These elements are particularly important in longitudinal study designs including interventions where attrition is critical to avoid, and high response rates improve the interpretation of results. Dried Blood Spot sample collection is simple, quick, relatively painless, less invasive then venipuncture, and requires minimal field storage requirements (i.e. samples do not need to be immediately frozen and can be stored for a long period of time in a stable freezer environment before assay). The samples can be analyzed for a variety of different analytes, including cholesterol, C-reactive protein, glycosylated hemoglobin, numerous cytokines, and other analytes, as well as provide genetic material. DBS collection is depicted as employed in several recent studies. PMID:24513728
Innovative approaches to vitamin A assessment.
Craft, N E
2001-05-01
The health and sight of millions of children are compromised each year as a consequence of vitamin A (VA) deficiency. Serum retinol is the most commonly used indicator of VA status. Unfortunately, its use is impractical for national surveys because it involves collection of venous blood, centrifugation and frozen storage before analysis. To make VA assessment more practical, we have developed approaches incorporating dried blood spots (DBS) or portable instrumentation. DBS have been used as a sample matrix to screen neonates for many biochemical compounds. Until recently, it was not thought that VA was stable in DBS. However, we demonstrated that the measure of DBS retinol correlates well with serum retinol in both healthy adults (r(2) = 0.88-0.90) and compromised populations (r(2) = 0.73-0.84). Compared with serum retinol, the sensitivity and specificity of detecting VA deficiency by DBS retinol range from 73 to 93% and from 90 to 100%, respectively. Although few data are available, retinol binding protein (RBP) can also be measured in DBS. RBP has been used as a surrogate marker for serum retinol. Correlations coefficients (r(2)) between serum RBP and serum retinol range from 0.4 to 0.8. In addition, work has been done to develop portable instrumentation to measure VA status in the field. A fluorometer has been optimized for VA fluorescence and is linear into the deficient range for the direct fluorimetric measurement of serum holo-RBP. Progress is being made to use the instrument to directly measure holo-RBP in a drop of whole blood.
Moretti, Matteo; Visonà, Silvia Damiana; Freni, Francesca; Tomaciello, Ilaria; Vignali, Claudia; Groppi, Angelo; Tajana, Luca; Osculati, Antonio Marco Maria; Morini, Luca
2018-05-04
The aims of this study were (1) to identify and quantify cocaine (COC), benzoylecgonine (BE), ecgonine methyl ester (EME), and cocaethylene (CE) in DBS; (2) to compare dried blood spots (DBSs) analytical results with the routine blood analyses; (3) to monitor analytes stability on DBS within a 3-month period. Eighty-five μL of blood from postmortem cases were put on a card for DBS analysis and kept in the dark, at room temperature. Samples were extracted through solid-phase extraction (SPE) cartridges and injected in the liquid chromatography-tandem mass spectrometry (LC-MS/MS) system. The analytical procedure is simple, sensitive, and specific. Limits of detection (LODs) and quantification (LOQs) were calculated at 1.0 and 5.0 ng/mL(g) for COC and CE, and at 0.5 and 2 ng/mL for EME and BE, respectively. Validation parameters fulfilled all the acceptance criteria. Fifty-five postmortem cases were evaluated. Eighteen cases were positive for COC (44-2456 ng/mL) and BE (228-4700 ng/mL), 12 for EME (92-1500 ng/mL), and 11 cases for CE (11-273 ng/mL). Stability was evaluated on 8 cases collected in the period January 2017-January 2018. For each case, 5 DBSs were collected at T0. Four DBSs were analyzed within the 4 following weeks and 1 sample was analyzed after 3 months. The concentrations on DBSs, stored at room temperature, always matched the ones obtained on blood samples kept at -20°C (<20% variation, both at T0 and after 3 months). BE and COC concentrations remained stable after a 3-month storage, EME concentrations slightly increased after 3 weeks in the 2 analyzed samples, while CE provided a less homogeneous stability depending on the sample. Copyright © 2018 John Wiley & Sons, Ltd.
Lenk, Gabriel; Sandkvist, Sören; Pohanka, Anton; Stemme, Göran; Beck, Olof; Roxhed, Niclas
2015-01-01
DBS samples collected from a fingerprick typically vary in volume and homogeneity and hence make an accurate quantitative analysis of DBS samples difficult. We report a prototype which first defines a precise liquid volume and subsequently stores it to a conventional DBS matrix. Liquid volumes of 2.2 µl ± 7.1% (n = 21) for deionized water and 6.1 µl ± 8.8% (n = 15) for whole blood have been successfully metered and stored in DBS paper. The new method of collecting a defined volume of blood by DBS sampling has the potential to reduce assay bias for the quantitative evaluation of DBS samples while maintaining the simplicity of conventional DBS sampling.
Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.
Protti, Michele; Rudge, James; Sberna, Angelo Eliseo; Gerra, Gilberto; Mercolini, Laura
2017-02-15
Synthetic cannabinoids are new psychoactive substances (NPS) with similar effects when compared to natural ones found in Cannabis derivatives. They have rapidly integrated into the illicit market, often sold as alternatives under international control. The need to identify and quantify an unprecedented and growing number of new compounds represents a unique challenge for toxicological, forensic and anti-doping analysis. Dried blood spots have been used within the bioanalytical framework in place of plasma or serum, in order to reduce invasiveness, lower sample size, simplify handling, storage and shipping of samples and to facilitate home-based and on-field applications. However, DBS implementation has been limited mainly by concerns related to haematocrit effect on method accuracy. Volumetric absorptive microsampling (VAMS™), a second generation dried miniaturized sampling technology, has been developed just in order to eliminate haematocrit effect, thus providing accurate sampling but still granting feasible sample processing. An original LC-MS/MS method was herein developed and validated for the analysis of THC and its 2 main metabolites, together with 10 representative synthetic cannabinoids in both DBS and VAMS dried microsamples. The ultimate goal of this work is to provide highly innovative DBS and VAMS analytical protocols, whose performances were extensively optimized and compared, in order to provide effective and alternative tools that can be applied for natural and synthetic cannabinoid determination, in place of classical analytical strategies. Copyright © 2016 Elsevier B.V. All rights reserved.
Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.
Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno
2016-06-01
A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.
Dockendorf, Marissa F; Murthy, Gowri; Bateman, Kevin P; Kothare, Prajakti A; Anderson, Melanie; Xie, Iris; Sachs, Jeff R; Burlage, Rubi; Goldman, Andra; Moyer, Matthew; Shah, Jyoti; Ruba, Rachel; Shipley, Lisa; Harrelson, Jane
2018-06-09
Merck & Co., Inc. (Kenilworth, New Jersey) is investing in approaches to enrich clinical trial data and augment decision-making through utilization of digital health technologies, outpatient sampling, and real-time data access. As part of this strategy, a Phase 1 study was conducted to explore a few technologies of interest. In this fixed-sequence, two-period trial, 16 healthy subjects were administered 50-mg once-daily sitagliptin packaged in a bottle that electronically captured the date and time study medication was dispensed (Period 1) and in a traditional pharmacy bottle (Period 2). Dried blood spot (DBS) samples were collected for sitagliptin concentration analysis on select study days, both in-clinic and at-home, with collection time recorded using an electronic diary in Period 1 and by clinic staff in Period 2. Study results demonstrated the feasibility and subject acceptance of collecting digital adherence data and outpatient DBS samples in clinical trials and highlighted areas for future improvements. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Herrera, D; Monaga, M; Campos, D; Pampín, Y; González, E C; Lavaut, K
2013-01-01
Gaucher disease (GD) is a lysosomal storage disorder characterized by a deficiency of the lysosomal acid β-D-glucosidase (GBA). The aim of this study was to develop an ultramicro-fluorometric assay based on the method of Chamoles et al. for determining GBA activity in dried blood spots on filter paper (DBS). The assay used 3-mm diameter blood spot and 8 mmol/l of 4-methylumbelliferyl-β-D-glucoside as enzymatic substrate. The reaction occurred in plates incubated at 37°C for 20 hours and the enzyme activity was expressed in μmol hydrolysed substrate/l blood/h. The fluorescence of the enzyme product was automatically measured in a fluorometer-photometer reader (SUMA Technology). The intra and inter-assay coefficients of variation were lower than 9 and 12%, respectively, and the recovery range was 97-109%.Three patients with GD were correctly diagnosed using the ultramicroassay. Healthy newborn DBS samples (n = 3003) from the National Neonatal Screening Program were analyzed, and the mean GBA activity was 5.7 μmol/l blood/h. Our assay showed high Pearson (n = 26; r = 0.99) and concordance correlations (ρc = 0.99) with the traditional method described by Chamoles et al. The analytical performance characteristics of our ultramicro-fluorometric assay suggest that it can be used in the diagnosis of GD in newborns and adults.
NASA Astrophysics Data System (ADS)
Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.
2018-01-01
Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.
la Marca, Giancarlo; Giocaliere, Elisa; Malvagia, Sabrina; Villanelli, Fabio; Funghini, Silvia; Ombrone, Daniela; Della Bona, Maria; Forni, Giulia; Canessa, Clementina; Ricci, Silvia; Romano, Francesca; Guerrini, Renzo; Resti, Massimo; Azzari, Chiara
2016-04-01
Purine nucleoside phosphorylase (PNP) deficiency has been recently introduced in the newborn screening program in Tuscany. In order to improve the PNP screening efficiency, we developed a 2nd tier test to quantify PNP primary markers deoxyguanosine (dGuo) and deoxyinosine (dIno). Dried blood spots (DBS) samples were extracted with 200 μL of methanol and 100 μL of water (by two steps). Internal standards were added at a final concentration of 10 μmol/L. After extraction, samples were analysed by LC-MS/MS. The chromatographic run was performed in gradient mode by using a Synergi Fusion column. The assay was linear over a concentration range of 0.05-50 μmol/L (R2>0.999) for dGuo and 0.5-50 μmol/L (R2>0.998) for dIno. Intra- and interassay imprecision (mean CVs) for dIno and dGuo ranged from 2.9% to 12%. Limit of quantitaion (LOQ) were found to be 0.05 μmol/L and 0.5 μmol/L for dGuo and dIno, respectively. The reference ranges, obtained by measuring dGuo and dIno concentrations on DBS, were close to zero for both biomarkers. Moreover, DBS samples from seven patients with confirmed PNP were retrospectively evaluated and correctly identified. The LC-MS/MS method can reliably measure dIno and dGuo in DBS for the diagnosis of PNP. Validation data confirm the present method is characterised by good reproducibility, accuracy and imprecision for the quantitation of dIno and dGuo. The assay also appears suitable for use in monitoring treatment of PNP patients.
Fernández McPhee, Carolina; Álvarez, Patricia; Prieto, Luis; Obiang, Jacinta; Avedillo, Pedro; Vargas, Antonio; Rojo, Pablo; Abad, Carlota; Ramos, José Tomás; Holguín, Africa
2015-02-01
Confirmatory assays for HIV diagnosis are not well implemented in low-income countries with limited infrastructures. Geenius™ HIV 1/2 Confirmatory Assay is a single-use immunochromatographic test for the confirmation and differentiation of individual HIV-1/2 antibodies validated in venous whole blood, serum and plasma. However, dried blood specimens (DBS) are easier to collect, store and transport than plasma/serum in remote settings from limited resource countries and mobile populations. To evaluate the confirmatory assay Geenius™ HIV 1/2 for HIV diagnosis using DBS specimens. We collected DBS from 70 Guinean women previously diagnosed as HIV-1 infected by rapid tests using whole blood samples in Equatorial Guinea and from 25 HIV-negative Guinean women and HIV-exposed infants diagnosed by molecular testing in Madrid. Geenius HIV 1/2 was performed by eluting two drops of dried blood from each patient and following the manufacturer instructions for the assay but using 40μl of the eluted blood as specimen. The results obtained were confirmed by western blot. Geenius™ HIV 1/2 successfully confirmed the HIV-1 positive and negative infection in all tested DBS specimens, providing 100% specificity [95% Confidence Interval (CI): 86.2%-100%]. No HIV 1/2 coinfections were found in the study cohort. This is the first report that proves a good performance of Geenius™ HIV 1/2 for the HIV-1 infection confirmation using only two drops of dried blood. Our results approve the utility of this confirmatory assay using DBS when a lack of adequate infrastructure to collect, store or transport plasma/serum is found. DBS are a practical alternative to plasma/serum for HIV serological diagnosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Quantitation of brinzolamide in dried blood spots by a novel LC-QTOF-MS/MS method.
Foivas, Anargyros; Malenović, Anđelija; Kostić, Nađa; Božić, Marija; Knežević, Miroslav; Loukas, Yannis L; Dotsikas, Yannis
2016-02-05
In the current study, a rapid and sensitive LC-QTOF-MS/MS method for the determination of brinzolamide in dried blood spots (DBS) was developed and validated. This novel sample collection, storage and transfer technique was suitable for analyzing a drug with high distribution into red blood cells and negligible plasma levels. The method included an isocratic mobile phase consisting of methanol and 10mM ammonium formate (90:10, v/v) and detection in positive electrospray mode (ESI+). The flow rate was adjusted to 0.350mL/min yielding retention times of 1.7min for both brinzolamide and internal standard (IS) rabeprazole on a Cyano analytical column, respectively. The validation of the proposed method over the concentration range 0.500-20.0μg/mL was performed in compliance with EMEA and FDA guidelines, assessing all major performance characteristics. Inter- and intra- assay precisions were less than 14%, while inter- and intra- assay accuracies varied from 92.2 to 111%. No matrix effect was observed and the mean brinzolamide extraction recovery was 93.5%. The method was successfully applied to real DBS samples from patients in steady state condition, receiving brinzolamide ophthalmic suspension 1% (w/v) for several months. Initial concentrations were corrected due to hematocrit effect, using image processing algorithm written in Matlab. Copyright © 2015 Elsevier B.V. All rights reserved.
Chepyala, Divyabharathi; Tsai, I-Lin; Liao, Hsiao-Wei; Chen, Guan-Yuan; Chao, Hsi-Chun; Kuo, Ching-Hua
2017-03-31
An increased rate of drug abuse is a major social problem worldwide. The dried blood spot (DBS) sampling technique offers many advantages over using urine or whole blood sampling techniques. This study developed a simple and efficient ultra-high-performance liquid chromatography-ion booster-quadrupole time-of-flight mass spectrometry (UHPLC-IB-QTOF-MS) method for the analysis of abused drugs and their metabolites using DBS. Fifty-seven compounds covering the most commonly abused drugs, including amphetamines, opioids, cocaine, benzodiazepines, barbiturates, and many other new and emerging abused drugs, were selected as the target analytes of this study. An 80% acetonitrile solvent with a 5-min extraction by Geno grinder was used for sample extraction. A Poroshell column was used to provide efficient separation, and under optimal conditions, the analytical times were 15 and 5min in positive and negative ionization modes, respectively. Ionization parameters of both electrospray ionization source and ion booster (IB) source containing an extra heated zone were optimized to achieve the best ionization efficiency of the investigated abused drugs. In spite of their structural diversity, most of the abused drugs showed an enhanced mass response with the high temperature ionization from an extra heated zone of IB source. Compared to electrospray ionization, the ion booster (IB) greatly improved the detection sensitivity for 86% of the analytes by 1.5-14-fold and allowed the developed method to detect trace amounts of compounds on the DBS cards. The validation results showed that the coefficients of variation of intra-day and inter-day precision in terms of the signal intensity were lower than 19.65%. The extraction recovery of all analytes was between 67.21 and 115.14%. The limits of detection of all analytes were between 0.2 and 35.7ngmL -1 . The stability study indicated that 7% of compounds showed poor stability (below 50%) on the DBS cards after 6 months of storage at room temperature and -80°C. The reported method provides a new direction for abused drug screening using DBS. Copyright © 2017 Elsevier B.V. All rights reserved.
Chang, Joy; Tarasova, Tetyana; Shanmugam, Vedapuri; Azarskova, Marianna; Nguyen, Shon; Hurlston, Mackenzie; Sabatier, Jennifer; Zhang, Guoqing; Osmanov, Saladin; Ellenberger, Dennis; Yang, Chunfu; Vitek, Charles; Liulchuk, Maria; Nizova, Natalya
2015-12-01
An accurate accessible test for early infant diagnosis (EID) is crucial for identifying HIV-infected infants and linking them to treatment. To improve EID services in Ukraine, dried blood spot (DBS) samples obtained from 237 HIV-exposed children (≤18 months of age) in six regions in Ukraine in 2012 to 2013 were tested with the AmpliSens DNA-HIV-FRT assay, the Roche COBAS AmpliPrep/COBAS TaqMan (CAP/CTM) HIV-1 Qual test, and the Abbott RealTime HIV-1 Qualitative assay. In comparison with the paired whole-blood results generated from AmpliSens testing at the oblast HIV reference laboratories in Ukraine, the sensitivity was 0.99 (95% confidence interval [CI], 0.95 to 1.00) for the AmpliSens and Roche CAP/CTM Qual assays and 0.96 (95% CI, 0.90 to 0.98) for the Abbott Qualitative assay. The specificity was 1.00 (95% CI, 0.97 to 1.00) for the AmpliSens and Abbott Qualitative assays and 0.99 (95% CI, 0.96 to 1.00) for the Roche CAP/CTM Qual assay. McNemar analysis indicated that the proportions of positive results for the tests were not significantly different (P > 0.05). Cohen's kappa (0.97 to 0.99) indicated almost perfect agreement among the three tests. These results indicated that the AmpliSens DBS and whole-blood tests performed equally well and were comparable to the two commercially available EID tests. More importantly, the performance characteristics of the AmpliSens DBS test meets the World Health Organization EID test requirements; implementing AmpliSens DBS testing might improve EID services in resource-limited settings. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Koop, Dennis R; Bleyle, Lisa A; Munar, Myrna; Cherala, Ganesh; Al-Uzri, Amira
2013-05-01
Long term therapeutic drug monitoring and assessment of renal function are required in renal transplant recipients on immunosuppressant therapy such as tacrolimus. Dry blood spots (DBS) have been used successfully in the clinic for many years and offers a convenient, simple and non-invasive method for repeated blood tests. We developed and performed a preliminary validation of a method for the analysis of tacrolimus and creatinine from a single DBS using liquid chromatography-tandem mass spectrometric (LC-MS/MS). Tacrolimus and creatinine were extracted from a 6mm punch with a mixture of methanol/acetonitrile containing ascomycin and deuterated creatinine as internal standards. A 10 μl aliquot of the extract was analyzed directly after dilution for creatinine with normal phase high performance liquid chromatography and multiple reaction monitoring. The remainder of the extract was processed and analyzed for tacrolimus. The lower limit of quantification for tacrolimus was 1 ng/ml with accuracy of 0.34% bias and precision (CV) of 11.1%. The precision ranged from 1.33% to 7.68% and accuracy from -4.44% to 11.6% bias for the intra- and inter-day analysis. The lower limit of quantification of creatinine was 0.01 mg/dL with precision of 7.94%. Accuracy was based on recovery of additional creatinine spiked into whole blood samples and ranged from -2.45% bias at 5 mg/dL to 3.75% bias at 0.5 mg/dL. Intra- and inter-day precision was from 3.48 to 4.11%. The assay was further validated with DBS prepared from pediatric renal transplant recipients. There was excellent correlation between the levels of tacrolimus and creatinine obtained from the clinical laboratory and the DBS method developed. After additional validation, this assay may have a significant impact on compliance with medication intake as well as potentially lowering the cost associated with intravenous blood draws in clinical laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.
Irie, Kei; Shobu, Saori; Hiratsuji, Seika; Yamasaki, Yuta; Nanjo, Shigeki; Kokan, Chiyuki; Hata, Akito; Kaji, Reiko; Masago, Katsuhiro; Fujita, Shiro; Okada, Yutaka; Katakami, Nobuyuki; Fukushima, Shoji
2018-06-15
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of gefitinib in dried blood spots (DBSs). Gefitinib was extracted with methanol from DBS of 3 mm in diameter and detected using a triple quadrupole mass spectrometer. The method was validated by evaluating its precision, accuracy, selectivity, carryover, matrix effect, recovery, and stability. For clinical validation, paired finger-prick DBS and plasma concentrations were compared for 10 patients with non-small cell lung cancer (NSCLC) taking gefitinib. The calibration linear range was 37.5-2400 ng/mL (coefficient of determination [R 2 ] = 0.99), encompassing the therapeutic concentrations of gefitinib. The accuracy and precision were within 15% of the quality control (QC) concentrations of 80, 200, and 2000 ng/mL. The lower limit of quantification was determined to be 40 ng/mL. Gefitinib was stable in DBSs for up to 5 months at room temperature and -20 °C, and at 40 °C for 24 h. A good correlation was observed between the gefitinib levels measured by the DBS method and plasma concentrations (R 2 = 0.99). This method provides a simple, fast, and accurate approach to the quantitative analysis of gefitinib in finger-prick DBSs. The method would be useful for minimally invasive evaluation of the clinical gefitinib blood concentration. Copyright © 2018 Elsevier B.V. All rights reserved.
Castro, Andréa Cauduro de; Borges, Luiz Gustavo dos Anjos; Souza, Ricardo da Silva de; Grudzinski, Melina; D'Azevedo, Pedro Alves
2008-01-01
Human Immunodeficiency Virus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and immunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS-Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 degrees C, -20 degrees C and -70 degrees C, while the second was composed of two negative and three positive samples stored at 37 degrees C (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.
Moreira, Vanessa; Brasili, Elisa; Fiamoncini, Jarlei; Marini, Federico; Miccheli, Alfredo; Daniel, Hannelore; Lee, Jennifer Ji Hye; Hassimotto, Neuza Mariko Aymoto; Lajolo, Franco Maria
2018-05-01
Citrus juices, especially orange juice, constitute rich sources of bioactive compounds with a wide range of health-promoting activities. Data from epidemiological and in vitro studies suggest that orange juice (OJ) may have a positive impact on lipid metabolism. However, the effect of orange juice intake on blood lipid profile is still poorly understood. We have used two different blood samples, Dried Blood Spots (DBS) and plasma, to assess the effect of two-week orange juice consumption in healthy volunteers by a mass-spectrometry based metabolomics approach. DBS were analysed by liquid chromatography mass spectrometry (LC-MS) and plasma samples were analysed by the gas chromatography mass spectrometry (GC-MS). One hundred sixty-nine lipids including acylcarnitines (AC), lysophosphatidylcholines (LysoPC), (diacyl- and acyl-alkyl-) phosphatidylcholines (PC aa and PC ae) and sphingomyelins (SM) were identified and quantified in DBS. Eighteen fatty acids were identified and quantified in plasma. Multivariate analysis allowed to identify an increase in C3:1, C5-DC(C6-OH), C5-M-DC, C5:1-DC, C8, C12-DC, lysoPC18:3, myristic acid, pentadecanoic acid, palmitoleic and palmitic acid and a decrease in nervonic acid, C0, C2, C10, C10:1, C16:1, C16-OH, C16:1-OH, C18-OH, PC aa C40:4, PC ae C38:4, PC ae C42:3, PC ae C42:4 and cholesterol levels after orange juice intake. A two-week period of orange juice intake could affect fatty acids β-oxidation through mitochondrial and peroxisomal pathways, leading to an increase of short-chain acylcarnitines and a decrease of medium and long-chain acylcarnitines. This is the first report analyzing the effect of orange juice intake in healthy volunteers using a dried blood spot-based metabolomics approach. Copyright © 2018 Elsevier Ltd. All rights reserved.
LOPED study: looking for an early diagnosis in a late-onset Pompe disease high-risk population.
Musumeci, O; la Marca, G; Spada, M; Mondello, S; Danesino, C; Comi, G P; Pegoraro, E; Antonini, G; Marrosu, G; Liguori, R; Morandi, L; Moggio, M; Massa, R; Ravaglia, S; Di Muzio, A; Filosto, M; Tonin, P; Di Iorio, G; Servidei, S; Siciliano, G; Angelini, C; Mongini, T; Toscano, A
2016-01-01
A multicentre observational study was aimed to assess the prevalence of late-onset Pompe disease (LOPD) in a large high-risk population, using the dried blood spot (DBS) as a main screening tool. 17 Italian neuromuscular centres were involved in the late-onset Pompe early diagnosis (LOPED) study. Inclusion criteria were: (1) age ≥5 years, (2) persistent hyperCKaemia and (3) muscle weakness at upper and/or lower limbs (limb-girdle muscle weakness, LGMW). Acid α-glucosidase (GAA) activity was measured separately on DBS by fluorometric as well as tandem mass spectrometry methods. A DBS retest was performed in patients resulted positive at first assay. For the final diagnosis, GAA deficiency was confirmed by a biochemical assay in skeletal muscle, whereas genotype was assessed by GAA molecular analysis. In a 14-month period, we studied 1051 cases: 30 positive samples (2.9%) were detected by first DBS screening, whereas, after retesting, 21 samples were still positive. Biochemical and molecular genetic studies finally confirmed LOPD diagnosis in 17 cases (1.6%). The median time from the onset of symptoms/signs to diagnosis was 5 years. Among those patients, 35% showed presymptomatic hyperCKaemia and 59% showed hyperCKaemia+LGMW, whereas 6% manifested with LGMW. LOPED study suggests that GAA activity should be accurately screened by DBS in all patients referring for isolated hyperCKaemia and/or LGMW. A timely diagnosis was performed in five patients with presymptomatic hyperCKaemia, but two had already manifested with relevant changes on muscle morphology and MRI. Consequently, enzyme replacement therapy was started in 14/17 patients, including the 2 patients still clinically presymptomatic but with a laboratory evidence of disease progression. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Keel, P; Edwards, G; Flood, J; Nixon, G; Beebeejaun, K; Shute, J; Poh, J; Millar, A; Ijaz, S; Parry, J; Mandal, S; Ramsay, M; Amirthalingam, G
2016-07-01
Despite national guidance recommending testing and vaccination of household contacts of hepatitis B-infected pregnant women, provision and uptake of this is sub-optimal. The aim of this study was to evaluate the use of in-home dried blood spot (DBS) testing to increase testing and vaccination of household contacts of hepatitis B-infected pregnant women as an alternative approach to conventional primary-care follow-up. The study was conducted across two London maternity trusts (North Middlesex and Newham). All hepatitis B surface antigen-positive pregnant women identified through these trusts were eligible for inclusion. The intervention of in-home DBS testing for household contacts was introduced at North Middlesex Trust from November 2010 to December 2011. Data on testing and vaccination uptake from GP records across the two trusts were compared between baseline (2009) and intervention (2010-2011) periods. In-home DBS service increased testing uptake for all ages (P < 0·001) with the biggest impact seen in partners, where testing increased from 30·3% during the baseline period to 96·6% during the intervention period in North Middlesex Trust. Although impact on vaccine uptake was less marked, improvements were observed for adults. The provision of nurse-led home-based DBS may be useful in areas of high prevalence.
Konishi, Shoko; Brindle, Eleanor; Guyton, Amanda; O’Connor, Kathleen A.
2014-01-01
Between-individual variation of salivary progesterone (P4) and cortisol levels does not always closely reflect blood hormone concentrations. This may be partly a function of individual differences in salivary hormone excretion. We tested whether time of day at sampling and ethnicity contributed to individual variation in salivary hormones after adjusting for blood hormone levels. Forty-three Caucasian and 15 Japanese women (18–34 years) collected four sets of matched dried blood spot (DBS) and saliva specimens across a menstrual cycle (N = 232 specimen sets). Linear fixed-effects (LFE) models were used to estimate the effects of diurnal variation and ethnicity on salivary P4 and cortisol while adjusting for DBS levels. For each hormone, women with exclusively positive or negative residuals (unexplained variance) from the LFE models were categorized as high- or low-saliva-to-DBS hormone ratio (SDR; high or low salivary secretors), respectively. We found that salivary P4 (P < 0.05) was significantly higher in early morning compared to the afternoon, after controlling for DBS levels, ethnicity, and BMI. After further adjusting for this diurnal effect, significant individual variation in salivary P4 and cortisol remained: sixteen and nine women, respectively were categorized as low or high salivary secretors for both hormones (P < 0.001), suggesting systematic individual-specific variation of salivary hormonal concentration. We conclude that when saliva is used to quantify P4 or cortisol levels, time of day at sampling should be controlled. Even with this adjustment, salivary P4 and cortisol do not closely mirror between-individual variation of serum P4 and cortisol in a substantial proportion of individuals. PMID:22826025
Newborn screening for lysosomal storage disorders by tandem mass spectrometry in North East Italy.
Burlina, Alberto B; Polo, Giulia; Salviati, Leonardo; Duro, Giovanni; Zizzo, Carmela; Dardis, Andrea; Bembi, Bruno; Cazzorla, Chiara; Rubert, Laura; Zordan, Roberta; Desnick, Robert J; Burlina, Alessandro P
2018-03-01
Lysosomal storage diseases (LSDs) are inborn errors of metabolism resulting from 50 different inherited disorders. The increasing availability of treatments and the importance of early intervention have stimulated newborn screening (NBS) to diagnose LSDs and permit early intervention to prevent irreversible impairment or severe disability. We present our experience screening newborns in North East Italy to identify neonates with Mucopolysaccharidosis type I (MPS I) and Pompe, Fabry, and Gaucher diseases. Activities of acid β-glucocerebrosidase (ABG; Gaucher), acid α-glucosidase (GAA; Pompe), acid α-galactosidase (GLA; Fabry), and acid α-L-iduronidase (IDUA; MPS-I) in dried blood spots (DBS) from all newborns during a 17-month period were determined by multiplexed tandem mass spectrometry (MS/MS) using the NeoLSD ® assay system. Enzymatic activity cutoff values were determined from 3500 anonymous newborn DBS. In the screening study, samples were retested if the value was below cutoff and a second spot was requested, with referral for confirmatory testing and medical evaluation if a low value was obtained. From September 2015 to January 2017, 44,411 newborns were screened for the four LSDs. We recalled 40 neonates (0.09%) for collection of a second DBS. Low activity was confirmed in 20, who had confirmatory testing. Ten of 20 had pathogenic mutations: two Pompe, two Gaucher, five Fabry, and one MPS-I. The incidences of Pompe and Gaucher diseases were similar (1/22,205), with Fabry disease the most frequent (1/8882) and MPS-I the rarest (1/44411). The combined incidence of the four disorders was 1/4411 births. Simultaneously determining multiple enzyme activities by MS/MS, with a focus on specific biochemical markers, successfully detected newborns with LSDs. The high incidence of these disorders supports this screening program.
Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples
Duarte, Ana Joana; Vieira, Luis
2013-01-01
Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677
Olagunju, Adeniyi; Amara, Alieu; Waitt, Catriona; Else, Laura; Penchala, Sujan D; Bolaji, Oluseye; Soyinka, Julius; Siccardi, Marco; Back, David; Owen, Andrew; Khoo, Saye
2015-10-01
The validation and clinical application of an LC-MS/MS method for the quantification of nevirapine in dried blood spots (DBS) and dried breast-milk spots (DBMS) are presented. DBS and DBMS were prepared from 50 and 30 μL of nevirapine-spiked whole blood and human breast milk, respectively. Chromatographic separation was achieved on a reverse-phase C18 column with 0.1% formic acid in water/acetonitrile using a solvent gradient programme at a flow rate of 400 μL/min, and detection was by a TSQ Quantum Access triple quadrupole mass spectrometer. The clinical application was evaluated in HIV-positive nursing mothers and their breastfed infants. The assay was validated over the concentration range 50-10,000 ng/mL. Accuracy ranged from 93.3% to 113.4% and precision ranged from 1.9% to 12.0%. The mean (percentage coefficient of variation) recovery of nevirapine from DBS and DBMS was ≥ 70.7% (≤ 8.2) and the matrix effect was ≤ 1.04 (≤ 6.1). Nevirapine was stable in DBS and DBMS for ≥ 15 months at room temperature and -80°C. Mean (SD) AUC0-12, Cmax and Cmin in maternal plasma versus breast milk were 57,808 ng · h/mL (24,315) versus 55,817 ng · h/mL (22,368), 6140 ng/mL (2605) versus 5231 ng/mL (2215) and 4334 ng/mL (1880) versus 4342 ng/mL (2245), respectively. The milk-to-plasma concentration ratio over the dosing interval was 0.94 (0.15). Infant plasma concentrations 2 and 8 h after maternal dosing were 580.6 ng/mL (464.7-1607) and 584.1 ng/mL (381.5-1570), respectively. These methods further extend opportunities for conducting clinical pharmacokinetic studies in nursing mother-infant pairs, especially in resource-limited settings. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Cé, Jaqueline; Rodrigues, Melissa Tôrres; Käfer, Eduarda Tassoni; da Costa Moraes, Vitória; Coelho, Janice Carneiro
2017-12-01
Mucopolysaccharidoses (MPS) occur due to deficiency in the activity of enzymes that catalyze the breakdown of glycosaminoglycans. MPS VII is caused by deficiency of the beta-glucuronidase enzyme (GUSB). This study aimed to enhance the technique to measure GUSB activity by reducing the amount of reagents and the size of the DBS, as well as to determine some biochemical parameters of enzyme of healthy individuals. The measurement of GUSB in 3 and 1.2mm DBS (with reagents reduced 2.5- and fourfold) was correlated and the precision of the technique was tested. Optimal pH, Km and Vmax, and thermostability parameters were determined and time and temperature of sample storage were established. The correlations among the techniques were significant. Although the correlation coefficient was similar, fourfold reduction was selected. pH4.4 had the highest enzyme activity. GUSB's Km was 1.25mM, while Vmax was 594.48nmol/h/mL. After pre-incubation of the sample at 60°C, its activity dropped from 100% to 15.8% at 120min. GUSB activity significantly decreased after 45days of storage at 4, 25, and 37°C. This research allowed a previously described technique for MPS VII diagnosis to be adapted for smaller amounts of sample and reagents. That will facilitate the use of smaller amounts of samples, which may be used for other techniques and to save material. Given the importance of early MPS VII diagnosis due to the severity of the disease, using reliable diagnostic techniques in DBS is essential. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Hu, Huiying; Jiang, Yulin; Zhang, Minghui; Liu, Shanying; Hao, Na; Zhou, Jing; Liu, Juntao; Zhang, Xiaojin; Ma, Liangkun
2017-03-01
To evaluate, side by side, the efficiency of dried blood spots (DBSs) against serum screening for Down's syndrome, and then, to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. One thousand eight hundred and thirty-seven low-risk Chinese women, with singleton pregnancy, were enrolled for the study. Alpha-fetoprotein and free beta human chorionic gonadotropin were measured for the serum as well as for the parallel DBS samples. Partial high-risk pregnant women identified by primary blood testing (n = 38) were also subject to the secondary cfDNA screening. Diagnostic amniocentesis was utilized to confirm the screening results. The true positive rate for Down's syndrome detection was 100% for both blood screening methods; however, the false-positive rate was 3.0% for DBS and 4.0% for serum screening, respectively. DBS correlated well with serum screening on Down's syndrome detection. Three out of 38 primary high-risk women displayed chromosomal abnormalities by cfDNA analysis, which were confirmed by amniocentesis. Either the true detection rate or the false-positive rate for Down's syndrome between DBS and the serum test is comparable. In addition, blood primary screening aligned with secondary cfDNA analysis, a "before and after" two-tier screening strategy, can massively decrease the false-positive rate, which, then, dramatically reduces the demand for invasive diagnostic operation. Impact statement Children born with Down's syndrome display a wide range of mental and physical disability. Currently, there is no effective treatment to ease the burden and anxiety of the Down's syndrome family and the surrounding society. This study is to evaluate the efficiency of dried blood spots against serum screening for Down's syndrome and to construct a two-tier strategy by topping up the fetal cell-free DNA (cfDNA) secondary screening over the high-risk women marked by the primary blood testing to build a practical screening tactic to identify fetal Down's syndrome. Results demonstrate that fetal cfDNA can significantly reduce false-positive rate close to none while distinguishing all true positives. Thus, we recommend that fetal cfDNA analysis to be utilized as a secondary screening tool atop of the primary blood protein screening to further minimize the capacity of undesirable invasive diagnostic operations.
Antelo-Domínguez, Ángel; Cocho, José Ángel; Tabernero, María Jesús; Bermejo, Ana María; Bermejo-Barrera, Pilar; Moreda-Piñeiro, Antonio
2013-12-15
A sample pre-treatment method based on blood spot collection filter cards was optimized as a means of using small volume samples for the screening and confirmation of cocaine and opiates abuse. Dried blood spots (DBSs) were prepared by dispersing 20 µL of whole blood specimens previously mixed with the internal standards (deuterated analogs of each target), and subjecting the whole DBS to extraction with 5 mL of methanol under orbital-horizontal shaking (180 rpm) for 10 min. Determinations were based on direct electrospray ionization tandem mass spectrometry (ESI-MS/MS) by injecting the re-dissolved methanol extract with the delivery solution (acetonitrile-water-formic acid, 80:19.875:0.125) at a flow rate of 60 µL min(-1), and using multiple reaction monitoring (MRM) mode with the m/z (precursor ion)→m/z (product ion) transitions for acquisition. Matrix effect has been found to be statistically significant (Multiple Range Test) when assessing cocaine, BZE, codeine and morphine, and the use of the standard addition method (dispersion of whole blood previously mixed with standards onto the filter papers) was needed for accurate determinations. The developed DBS-ESI-MS/MS procedure offered good intra-day and inter-day precisions (lower than 10% and 12%, respectively), as well as good intra-day and inter-day accuracies (inter-day absolute recoveries, expressed as the mean analytical recovery over three target concentration levels, of 103%, 100%, 101%, 98% and 100% for cocaine, BZE, codeine, morphine and 6-MAM, respectively). The high sensitivity inherent to MS/MS determinations combined with the minimal dilution of sample allowed low limits of quantification for all targets, and the developed method results therefore adequate for cocaine and opiates screening and confirmation purposes. The procedure was finally applied to DBSs prepared from whole blood from polydrug abusers, and results were compared with those obtained after a conventional sample pretreatment method based on solid phase extraction for plasma specimens and gas chromatography-mass spectrometry. © 2013 Elsevier B.V. All rights reserved.
Cramer, Benedikt; Osteresch, Bernd; Muñoz, Katherine A; Hillmann, Hartmut; Sibrowski, Walter; Humpf, Hans-Ulrich
2015-09-01
In this study, human exposure to the mycotoxin ochratoxin A (OTA) and its thermal degradation product 2'R-ochratoxin A (2'R-OTA, previously named as 14R-Ochratoxin A [22]) through coffee consumption was assessed. LC-MS/MS and the dried blood spot (DBS) technique were used for the analysis of blood samples from coffee and noncoffee drinkers (n = 50), and food frequency questionnaires were used to document coffee consumption. For the detection of OTA and 2'R-OTA in blood, a new sensitive and efficient sample preparation method based on DBS was established and validated. Using this technique 2'R-OTA was for the first time detected in biological samples. Comparison between coffee drinkers and noncoffee drinkers showed for the first time that 2'R-OTA was only present in blood from the first group while OTA could be found in both groups in a mean concentration of 0.21 μg/L. 2'R-OTA mean concentration was 0.11 μg/L with a maximum concentration of 0.414 μg/L. Thus, in average 2'R-OTA was approx. half the concentration of OTA but in some cases even exceeded OTA levels. No correlation between the amounts of coffee consumption and OTA or 2'R-OTA levels was observed. The results of this study revealed for the first time a high exposure of coffee consumers to 2'R-OTA, a compound formed from OTA during coffee roasting. Since little information is available regarding toxicity and possible carcinogenicity of this compound, further OTA monitoring in blood including 2'R-OTA is advisable. © 2015 The Authors. Molecular Nutrition & Food Research published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Cramer, Benedikt; Osteresch, Bernd; Muñoz, Katherine A.; Hillmann, Hartmut; Sibrowski, Walter
2015-01-01
Scope In this study, human exposure to the mycotoxin ochratoxin A (OTA) and its thermal degradation product 2’R‐ochratoxin A (2’R‐OTA, previously named as 14R‐Ochratoxin A [22]) through coffee consumption was assessed. LC‐MS/MS and the dried blood spot (DBS) technique were used for the analysis of blood samples from coffee and noncoffee drinkers (n = 50), and food frequency questionnaires were used to document coffee consumption. Methods and results For the detection of OTA and 2’R‐OTA in blood, a new sensitive and efficient sample preparation method based on DBS was established and validated. Using this technique 2’R‐OTA was for the first time detected in biological samples. Comparison between coffee drinkers and noncoffee drinkers showed for the first time that 2’R‐OTA was only present in blood from the first group while OTA could be found in both groups in a mean concentration of 0.21 μg/L. 2’R‐OTA mean concentration was 0.11 μg/L with a maximum concentration of 0.414 μg/L. Thus, in average 2’R‐OTA was approx. half the concentration of OTA but in some cases even exceeded OTA levels. No correlation between the amounts of coffee consumption and OTA or 2’R‐OTA levels was observed. Conclusion The results of this study revealed for the first time a high exposure of coffee consumers to 2’R‐OTA, a compound formed from OTA during coffee roasting. Since little information is available regarding toxicity and possible carcinogenicity of this compound, further OTA monitoring in blood including 2’R‐OTA is advisable. PMID:26012425
Powell, Douglas W; Blackmore, Sarah E; Puppa, Melissa; Lester, Deranda; Murray, Nicholas G; Reed-Jones, Rebecca J; Xia, Rui-Ping
2018-05-08
Deep brain stimulation (DBS) is associated with substantial improvements in motor symptoms of PD. Emerging evidence has suggested that nonlinear measures of complexity may provide greater insight into the efficacy of anti-PD treatments. This study investigated sample entropy and complexity index values in individuals with PD when DBS was OFF compared to ON. Five individuals with PD using DBS performed a four-minute treadmill walking task while 3D kinematics were collected over two periods of 30 s. Participants were tested in the DBS-ON and DBS-OFF conditions. Sample entropy (SE) and complexity index (CI) values were calculated for ankle, knee and hip joint angles. Paired samples t-tests were used to compare mean SE and CI values between the DBS-OFF and DBS-ON conditions, respectively. No differences in SE or CI were observed between the DBS-ON and DBS-OFF conditions at the ankle. At the knee, the DBS-ON was associated with greater SE and CI values than the DBS-OFF condition. At the hip, DBS-ON was associated with greater SE and CI values than the DBS-OFF condition. DBS enhances complexity of movement at the hip and knee joints while complexity at the ankle joint is not significantly altered. Greater complexity of knee and hip joint motion may represent increased adaptability and a greater number of available strategies to complete the gait task. Copyright © 2018 Elsevier B.V. All rights reserved.
Evaluation of the Aptima HIV-1 Quant Dx Assay Using Plasma and Dried Blood Spots
Sahoo, Malaya K.; Varghese, Vici; White, Elizabeth; Winslow, Meg; Katzenstein, David A.; Shafer, Robert W.
2016-01-01
HIV-1 RNA quantitation in plasma, or virus load testing, is the primary method by which the response to antiretroviral therapy is monitored. Here we describe evaluation of the Aptima HIV-1 Quant Dx assay (Aptima) performed on the automated Panther system. The clinical performance of Aptima was compared to that of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test v2.0 (CAP/CTM) using 162 EDTA plasma samples collected from patients undergoing HIV-1 monitoring. Overall agreement was 84.0% (136/162), with a kappa statistic of 0.723 (standard error, 0.047; 95% confidence interval [CI], 0.630 to 0.815), indicating substantial agreement. Using the 86 clinical samples quantifiable by both methods, Passing-Bablok regression revealed a regression line of Y = (1.069 × X) − 0.346 (95% CI of the slope [1.003 to 1.139] and intercept [−0.666 to −0.074]), and Bland-Altman analysis demonstrated a mean difference (Aptima-CAP/CTM) of −0.075 log10 copies/ml (95% limits of agreement of −0.624 to 0.475), consistent with negative bias. Comparison of Aptima results for paired dried blood spot (DBS) and plasma specimens archived from participants in the Peninsula AIDS Research Cohort Study (PARC) demonstrated an overall agreement of 94.7% (90/95) when 1,000 copies/ml was used as the threshold. In conclusion, the Aptima HIV-1 Quant Dx assay provides a suitable alternative for HIV-1 monitoring in plasma and DBS. PMID:27535684
Evaluation of the Aptima HIV-1 Quant Dx Assay Using Plasma and Dried Blood Spots.
Sahoo, Malaya K; Varghese, Vici; White, Elizabeth; Winslow, Meg; Katzenstein, David A; Shafer, Robert W; Pinsky, Benjamin A
2016-10-01
HIV-1 RNA quantitation in plasma, or virus load testing, is the primary method by which the response to antiretroviral therapy is monitored. Here we describe evaluation of the Aptima HIV-1 Quant Dx assay (Aptima) performed on the automated Panther system. The clinical performance of Aptima was compared to that of the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test v2.0 (CAP/CTM) using 162 EDTA plasma samples collected from patients undergoing HIV-1 monitoring. Overall agreement was 84.0% (136/162), with a kappa statistic of 0.723 (standard error, 0.047; 95% confidence interval [CI], 0.630 to 0.815), indicating substantial agreement. Using the 86 clinical samples quantifiable by both methods, Passing-Bablok regression revealed a regression line of Y = (1.069 × X) - 0.346 (95% CI of the slope [1.003 to 1.139] and intercept [-0.666 to -0.074]), and Bland-Altman analysis demonstrated a mean difference (Aptima-CAP/CTM) of -0.075 log10 copies/ml (95% limits of agreement of -0.624 to 0.475), consistent with negative bias. Comparison of Aptima results for paired dried blood spot (DBS) and plasma specimens archived from participants in the Peninsula AIDS Research Cohort Study (PARC) demonstrated an overall agreement of 94.7% (90/95) when 1,000 copies/ml was used as the threshold. In conclusion, the Aptima HIV-1 Quant Dx assay provides a suitable alternative for HIV-1 monitoring in plasma and DBS. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Sustainable HIV Treatment in Africa through Viral Load-Informed Differentiated Care
Phillips, Andrew; Shroufi, Amir; Vojnov, Lara; Cohn, Jennifer; Roberts, Teri; Ellman, Tom; Bonner, Kimberly; Rousseau, Christine; Garnett, Geoff; Cambiano, Valentina; Nakagawa, Fumiyo; Ford, Deborah; Bansi-Matharu, Loveleen; Miners, Alec; Lundgren, Jens; Eaton, Jeff; Parkes-Ratanshi, Rosalind; Katz, Zachary; Maman, David; Ford, Nathan; Vitoria, Marco; Doherty, Meg; Dowdy, David; Nichols, Brooke; Murtagh, Maurine; Wareham, Meghan; Palamountain, Kara; Musanhu, Christine Chiedza; Stevens, Wendy; Katzenstein, David; Ciaranello, Andrea; Barnabas, Ruanne; Braithwaite, Scott; Bendavid, Eran; Nathoo, Kusum J; van de Vijver, David; Wilson, David; Holmes, Charles; Bershteyn, Anna; Walker, Simon; Raizes, Elliot; Jani, Ilesh; Nelson, Lisa; Peeling, Rosanna; Terris-Prestholt, Fern; Murungu, Joseph; Mutasa-Apollo, Tsitsi; Hallett, Timothy; Revill, Paul
2016-01-01
There are inefficiencies in current approaches to monitoring patients on antiretroviral therapy (ART) in sub-Saharan Africa. Patients typically attend clinics every 1–3 months for clinical assessment, with clinic costs being comparable with costs of drugs themselves, CD4 counts are measured every 6 months, yet patients are rarely switched to second-line therapies. To ensure sustainability of treatment programmes a transition to more cost-effective ART deliver is needed. In contrast to the CD4 count, measurement of the level of HIV RNA in plasma (“viral load”) provides a direct measure of current treatment effect. Viral load informed differentiated care is a means of tailoring care whereby those with suppressed viral load have less frequent clinical visits and attention is paid to those with unsuppressed viral load to promote adherence and timely switching to a second-line regimen. The most feasible approach in many countries to measure viral load is by collecting dried blood spot (DBS) samples for testing in regional laboratories, although there have been concerns over the sensitivity/specificity of DBS to define treatment failure and the delay in receiving results. We use modelling to synthesize available evidence and evaluate the cost-effectiveness of viral load-informed differentiated care, account for limitations of DBS. We find that viral load-informed differentiated care using DBS is expected to be cost-effective and is recommended as the strategy for patient monitoring, although further empirical evidence as the approach is rolled out would be of value. We also explore the potential benefits of future availability of point-of-care (POC) viral load tests. PMID:26633768
Knapen, Lotte M; Beer, Yvo de; Brüggemann, Roger J M; Stolk, Leo M; Vries, Frank de; Tjan-Heijnen, Vivianne C G; Erp, Nielka P van; Croes, Sander
2018-02-05
While the therapeutic drug monitoring (TDM) of everolimus has been routinely performed for over 10 years in solid organ transplantation medicine, in order to optimize the balance between effectiveness and toxicity, it is yet uncommon in the treatment of malignancies. The aim of this study was to develop and validate a bioanalytical method to quantify everolimus in dried blood spots (DBS) to facilitate TDM for the oncology outpatient setting. The hematocrit effect of everolimus was investigated. An 7.5mm disk from the central part of the DBS was punched, followed by the extraction of everolimus from the DBS by methanol/acetonitrile (80/20%) spiked with deuterium-labelled everolimus as internal standard. Subsequently, everolimus was separated and analyzed using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The UPLC-MS/MS method was validated according to the European Medicine Agency (EMA) guideline. Everolimus concentrations could be quantified over the range of 3-75μg/L. The intra- and inter-assay precision and accuracy of the method were shown to be acceptable (coefficient of variation ≤10.7% and relative error ≤4.4%, respectively). The matrix effects appeared to be influenced by the hematocrit effect. The hematocrit effect was tested in a range of 0.20-0.50L/L, at which hematocrit accuracy and precision were satisfactory at values ≥0.25L/L. However, at 0.20L/L hematocrit in combination with high everolimus concentrations of 20 and 40μg/L, the precision was adequate (≤7.4%), but the accuracy was >15% of the nominal concentration. Everolimus was stable in DBS for at least 80days at 2-8°C. Given these results, the everolimus DBS method has been successfully developed and validated. Special attention is necessary for cancer patients with both a 0.20L/L hematocrit in combination with everolimus concentrations ≥20μg/L. A clinical validation for the use of everolimus DBS in cancer patients is currently being undertaken. Copyright © 2017 Elsevier B.V. All rights reserved.
DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana
2016-09-01
DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.
Parra-Guillen, Zinnia P; Berger, Peter B; Haschke, Manuel; Donzelli, Massimiliano; Winogradova, Daria; Pfister, Bogumila; Früh, Martin; Gillessen, Silke; Krähenbühl, Stephan; Kloft, Charlotte; Joerger, Markus
2017-10-01
Erlotinib is metabolized by cytochrome p450 (CYP) 3A and CYP1A. This study assessed CYP3A4 (midazolam) and CYP1A2 (caffeine) phenotyping in plasma and dried blood spots (DBS) for predicting the pharmacokinetics and toxicity of erlotinib in 36 patients with advanced NSCLC. On day 1, erlotinib 150 mg OD was initiated, and the two oral probe drugs midazolam (2 mg) and caffeine (100 mg) were added on day 1. Plasma and DBS were collected for erlotinib, OSI-420 and probe drugs for up to 6 hr on day 1 and 2-weekly up to week 10. Probe drugs, erlotinib and OSI-420 were analysed using LC-MS-MS, and PK data were processed using population modelling. A high correlation was found between plasma and DBS concentrations for erlotinib (R 2 = 0.960, p < 0.0001), OSI-420 (R 2 = 0.971, p < 0.0001), midazolam (R 2 = 0.995, p < 0.0001) and caffeine (R 2 = 0.968, p < 0.0001). Apparent oral caffeine clearance was significantly correlated with erlotinib clearance (R 2 = 0.33, p = 0.048), while midazolam clearance was not (R 2 = -0.09, p = 0.596). Erlotinib clearance was lower in patients experiencing grade 2 or 3 rash as compared to patients experiencing grade 0 or 1 rash (3.15 versus 3.93 L/hr, p = 0.086 for Student's t-test). The results suggest that probe drug phenotyping is unlikely to substitute therapeutic drug monitoring of erlotinib in patients with advanced NSCLC, but erlotinib PK sampling from DBS may replace more invasive venous sampling and facilitate TDM in patients with cancer. © 2017 Nordic Association for the Publication of BCPT (former Nordic Pharmacological Society).
Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.
Bio-repository of post-clinical test samples at the national cancer center hospital (NCCH) in Tokyo.
Furuta, Koh; Yokozawa, Karin; Takada, Takako; Kato, Hoichi
2009-08-01
We established the Bio-repository at the National Cancer Center Hospital in October 2002. The main purpose of this article is to show the importance and usefulness of a bio-repository of post-clinical test samples not only for translational cancer research but also for routine clinical oncology by introducing the experience of setting up such a facility. Our basic concept of a post-clinical test sample is not as left-over waste, but rather as frozen evidence of a patient's pathological condition at a particular point. We can decode, if not all, most of the laboratory data from a post-clinical test sample. As a result, the bio-repository is able to provide not only the samples, but potentially all related laboratory data upon request. The areas of sample coverage are the following: sera after routine blood tests; sera after cross-match tests for transfusion; serum or plasma submitted at a patient's clinically important time period by the physician; and samples collected by the individual investigator. The formats of stored samples are plasma or serum, dried blood spot (DBS) and buffy coat. So far, 150 218 plasmas or sera, 35 253 DBS and 536 buffy coats have been registered for our bio-repository system. We arranged to provide samples to various concerned parties under strict legal and ethical agreements. Although the number of the utilized samples was initially limited, the inquiries for sample utilization are now increasing steadily from both research and clinical sources. Further efforts to increase the benefits of the repository are intended.
Evaluation of Amount of Blood in Dry Blood Spots: Ring-Disk Electrode Conductometry.
Kadjo, Akinde F; Stamos, Brian N; Shelor, C Phillip; Berg, Jordan M; Blount, Benjamin C; Dasgupta, Purnendu K
2016-06-21
A fixed area punch in dried blood spot (DBS) analysis is assumed to contain a fixed amount of blood, but the amount actually depends on a number of factors. The presently preferred approach is to normalize the measurement with respect to the sodium level, measured by atomic spectrometry. Instead of sodium levels, we propose electrical conductivity of the extract as an equivalent nondestructive measure. A dip-type small diameter ring-disk electrode (RDE) is ideal for very small volumes. However, the conductance (G) measured by an RDE depends on the depth (D) of the liquid below the probe. There is no established way of computing the specific conductance (σ) of the solution from G. Using a COMSOL Multiphysics model, we were able to obtain excellent agreement between the measured and the model predicted conductance as a function of D. Using simulations over a large range of dimensions, we provide a spreadsheet-based calculator where the RDE dimensions are the input parameters and the procedure determines the 99% of the infinite depth conductance (G99) and the depth D99 at which this is reached. For typical small diameter probes (outer electrode diameter ∼ <2 mm), D99 is small enough for dip-type measurements in extract volumes of ∼100 μL. We demonstrate the use of such probes with DBS extracts. In a small group of 12 volunteers (age 20-66), the specific conductance of 100 μL aqueous extracts of 2 μL of spotted blood showed a variance of 17.9%. For a given subject, methanol extracts of DBS spots nominally containing 8 and 4 μL of blood differed by a factor of 1.8-1.9 in the chromatographically determined values of sulfate and chloride (a minor and major constituent, respectively). The values normalized with respect to the conductance of the extracts differed by ∼1%. For serum associated analytes, normalization of the analyte value by the extract conductance can thus greatly reduce errors from variations in the spotted blood volume/unit area.
la Marca, Giancarlo; Canessa, Clementina; Giocaliere, Elisa; Romano, Francesca; Malvagia, Sabrina; Funghini, Silvia; Moriondo, Maria; Valleriani, Claudia; Lippi, Francesca; Ombrone, Daniela; Della Bona, Maria Luisa; Speckmann, Carsten; Borte, Stephan; Brodszki, Nicholas; Gennery, Andrew R; Weinacht, Katja; Celmeli, Fatih; Pagel, Julia; de Martino, Maurizio; Guerrini, Renzo; Wittkowski, Helmut; Santisteban, Ines; Bali, Pawan; Ikinciogullari, Aydan; Hershfield, Michael; Notarangelo, Luigi D; Resti, Massimo; Azzari, Chiara
2014-07-01
Purine nucleoside phosphorylase (PNP) deficiency is a rare form of autosomal recessive combined primary immunodeficiency caused by a enzyme defect leading to the accumulation of inosine, 2'-deoxy-inosine (dIno), guanosine, and 2'-deoxy-guanosine (dGuo) in all cells, especially lymphocytes. Treatments are available and curative for PNP deficiency, but their efficacy depends on the early approach. PNP-combined immunodeficiency complies with the criteria for inclusion in a newborn screening program. This study evaluate whether mass spectrometry can identify metabolite abnormalities in dried blood spots (DBSs) from affected patients, with the final goal of individuating the disease at birth during routine newborn screening. DBS samples from 9 patients with genetically confirmed PNP-combined immunodeficiency, 10,000 DBS samples from healthy newborns, and 240 DBSs from healthy donors of different age ranges were examined. Inosine, dIno, guanosine, and dGuo were tested by using tandem mass spectrometry (TMS). T-cell receptor excision circle (TREC) and kappa-deleting recombination excision circle (KREC) levels were evaluated by using quantitative RT-PCR only for the 2 patients (patients 8 and 9) whose neonatal DBSs were available. Mean levels of guanosine, inosine, dGuo, and dIno were 4.4, 133.3, 3.6, and 3.8 μmol/L, respectively, in affected patients. No indeterminate or false-positive results were found. In patient 8 TREC levels were borderline and KREC levels were abnormal; in patient 9 TRECs were undetectable, whereas KREC levels were normal. TMS is a valid method for diagnosis of PNP deficiency on DBSs of affected patients at a negligible cost. TMS identifies newborns with PNP deficiency, whereas TREC or KREC measurement alone can fail. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
The national DBS brain tissue network pilot study: need for more tissue and more standardization.
Vedam-Mai, V; Krock, N; Ullman, M; Foote, K D; Shain, W; Smith, K; Yachnis, A T; Steindler, D; Reynolds, B; Merritt, S; Pagan, F; Marjama-Lyons, J; Hogarth, P; Resnick, A S; Zeilman, P; Okun, M S
2011-08-01
Over 70,000 DBS devices have been implanted worldwide; however, there remains a paucity of well-characterized post-mortem DBS brains available to researchers. We propose that the overall understanding of DBS can be improved through the establishment of a Deep Brain Stimulation-Brain Tissue Network (DBS-BTN), which will further our understanding of DBS and brain function. The objectives of the tissue bank are twofold: (a) to provide a complete (clinical, imaging and pathological) database for DBS brain tissue samples, and (b) to make available DBS tissue samples to researchers, which will help our understanding of disease and underlying brain circuitry. Standard operating procedures for processing DBS brains were developed as part of the pilot project. Complete data files were created for individual patients and included demographic information, clinical information, imaging data, pathology, and DBS lead locations/settings. 19 DBS brains were collected from 11 geographically dispersed centers from across the U.S. The average age at the time of death was 69.3 years (51-92, with a standard deviation or SD of 10.13). The male:female ratio was almost 3:1. Average post-mortem interval from death to brain collection was 10.6 h (SD of 7.17). The DBS targets included: subthalamic nucleus, globus pallidus interna, and ventralis intermedius nucleus of the thalamus. In 16.7% of cases the clinical diagnosis failed to match the pathological diagnosis. We provide neuropathological findings from the cohort, and perilead responses to DBS. One of the most important observations made in this pilot study was the missing data, which was approximately 25% of all available data fields. Preliminary results demonstrated the feasibility and utility of creating a National DBS-BTN resource for the scientific community. We plan to improve our techniques to remedy omitted clinical/research data, and expand the Network to include a larger donor pool. We will enhance sample preparation to facilitate advanced molecular studies and progenitor cell retrieval.
Dinh, Thu-Ha; Delaney, Kevin P.; Goga, Ameena; Jackson, Debra; Lombard, Carl; Woldesenbet, Selamawit; Mogashoa, Mary; Pillay, Yogan; Shaffer, Nathan
2015-01-01
Background Mother-to-child transmission of HIV (MTCT) depends on the timing of HIV infection. We estimated HIV-seroconversion during pregnancy (HSP) after having a HIV-negative result antenatally, and its contribution to early MTCT in South Africa (SA). Methods and Findings Between August 2011 and March 2012, we recruited a nationally representative sample of mother-infant pairs with infants aged 4-to-8 weeks from 578 health facilities. Data collection included mother interviews, child health-card reviews, and infant dried-blood-spots sample (iDBS). iDBS were tested for HIV antibodies and HIV-deoxyribonucleic-acid (HIV-DNA). HSP was defined as maternal self-report of an HIV-negative test during this pregnancy, no documented use of antiretroviral drugs and a matched HIV sero-positive iDBS. We used 20 imputations from a uniform distribution for time from reported antenatal HIV-negative result to delivery to estimate time of HSP. Early MTCT was defined based on detection of HIV-DNA in iDBS. Estimates were adjusted for clustering, nonresponse, and weighted by SA’s 2011 live-births. Results Of 9802 mother-infant pairs, 2738 iDBS were HIV sero-positive, including 212 HSP, resulting in a nationally weighted estimate of 3.3% HSP (95% Confidence Interval: 2.8%-3.8%). Median time of HIV-seroconversion was 32.8weeks gestation;28.3% (19.7%- 36.9%) estimated to be >36 weeks. Early MTCT was 10.7% for HSP (6.2%-16.8%) vs. 2.2% (1.7%-2.8%) for mothers with known HIV-positive status. Although they represent 2.2% of all mothers and 6.7% of HIV-infected mothers, HSP accounted for 26% of early MTCT. Multivariable analysis indicated the highest risk for HSP was among women who knew the baby’s father was HIV-infected (adjusted-hazard ratio (aHR) 4.71; 1.49-14.99), or who had been screened for tuberculosis (aHR 1.82; 1.43-2.32). Conclusions HSP risk is high and contributes significantly to early MTCT. Identification of HSP by repeat-testing at 32 weeks gestation, during labor, 6 weeks postpartum, in tuberculosis-exposed women, and in discordant couples might reduce MTCT. PMID:25942423
Bartelink, Imke H.; Savic, Rada M.; Mwesigwa, Julia; Achan, Jane; Clark, Tamara; Plenty, Albert; Charlebois, Edwin; Kamya, Moses; Young, Sera L.; Gandhi, Monica; Havlir, Diane; Cohan, Deborah; Aweeka, Francesca
2013-01-01
Pregnancy and food insecurity may impact antiretroviral (ART) pharmacokinetics (PK), adherence and response. We sought to quantify and characterize the PK of lopinavir/ritonavir (LPV/r) and efavirenz (EFV) by pregnancy and nutritional status among HIV-infected women in Tororo, Uganda. In 2011, 62/225 ante-partum/post-partum single dried blood spot samples DBS and 43 post-partum hair samples for LPV/r were derived from 116 women, 51/194 ante-/post-partum DBS and 53 post-partum hair samples for EFV from 105 women. 80% of Ugandan participants were severely food insecure, 26% lost weight ante-partum, and median BMI post-partum was only 20.2 kg/m2. Rich PK-data of normally nourished (pregnant) women and healthy Ugandans established prior information. Overall, drug exposure was reduced (LPV −33%, EFV −15%, ritonavir −17%) compared to well-nourished controls [p < 0.001], attributable to decreased bioavailability. Pregnancy increased LPV/r clearance 68% [p < 0.001], whereas EFV clearance remained unchanged. Hair concentrations correlated with plasma-exposure [p < 0.001], explaining 29% PK-variability. In conclusion, pregnancy and food insecurity were associated with lower ART exposures in this cohort of predominantly underweight women, compared to well-nourished women. Much variability in plasma-exposure was quantified using hair concentrations. Addressing malnutrition as well as ART-PK in this setting should be a priority. PMID:24038035
Gong, Zhen-Hua; Tian, Guo-Li; Huang, Qi-Wei; Wang, Yan-Min; Xu, Hong-Ping
2017-07-20
Glucose-6-phosphate dehydrogenase (G6PD) deficiency is commonly detected during mass screening for neonatal disease. We developed a method to measure reduced glutathione (GSH) and glutathione disulfide (GSSG) using tandem mass spectrometry (MS/MS) for detecting G6PD deficiency. The concentration of GSH and the GSH/GSSG ratio in newborn dry-blood-spot (DBS) screening and in blood plus sodium citrate for test confirmation were examined by MS/MS using labeled glycine as an internal standard. G6PD-deficient newborns had a lower GSH content (242.9 ± 15.9 μmol/L)and GSH/GSSG ratio (14.9 ± 7.2) than neonatal controls (370.0 ± 53.2 μmol/L and 46.7 ± 19.6, respectively). Although the results showed a significance of P < 0.001 for DBS samples plus sodium citrate that were examined the first day after preparation, there were no significant differences in the mean GSH concentration and GSH/GSSG ratio between the G6PD deficiency-positive and negative groups when examined three days after sample preparation. The concentration of GSH and the ratio of GSH/GSSG in blood measured using MS/MS on the first day of sample preparation are consistent with G6PD activity and are helpful for diagnosing G6PD deficiency.
Danese, Andrea; Shalev, Idan; Williams, Benjamin S.; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for four, 24 or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-Reactive Protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried Blood Spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data-collection conditions that involve processing delays. PMID:26652682
Kubaski, Francyne; Suzuki, Yasuyuki; Orii, Kenji; Giugliani, Roberto; Church, Heather J.; Mason, Robert W.; Dũng, Vũ Chí; Ngoc, Can Thi Bich; Yamaguchi, Seiji; Kobayashi, Hironori; Girisha, Katta M.; Fukao, Toshiyuki; Orii, Tadao; Tomatsu, Shunji
2017-01-01
Mucopolysaccharidoses (MPSs) and mucolipidoses (ML) are groups of lysosomal storage disorders in which lysosomal hydrolases are deficient leading to accumulation of undegraded glycosaminoglycans (GAGs), throughout the body, subsequently resulting in progressive damage to multiple tissues and organs. Assays using tandem mass spectrometry (MS/MS) have been established to measure GAGs in serum or plasma from MPS and ML patients, but few studies were performed to determine whether these assays are sufficiently robust to measure GAG levels in dried blood spots (DBS) of patients with MPS and ML. Material and methods In this study, we evaluated GAG levels in DBS samples from 124 MPS and ML patients (MPS I = 16; MPS II = 21; MPS III = 40; MPS IV = 32; MPS VI =10; MPS VII = 1; ML= 4), and compared them with 115 age-matched controls. Disaccharides were produced from polymer GAGs by digestion with chondroitinase B, heparitinase, and keratanase II. Subsequently, dermatan sulfate (DS), heparan sulfate (HS-0S, HS-NS), and keratan sulfate (mono-sulfated KS, di-sulfated KS, and ratio of di-sulfated KS in total KS) were measured by MS/MS. Results Untreated patients with MPS I, II, VI, and ML had higher levels of DS compared to control samples. Untreated patients with MPS I, II, III, VI, and ML had higher levels of HS-0S; and untreated patients with MPS II, III and VI and ML had higher levels of HS-NS. Levels of KS were age dependent, so although levels of both mono-sulfated KS and di-sulfated KS were generally higher in patients, particularly for MPS II and MPS IV, age group numbers were not sufficient to determine significance of such changes. However, the ratio of di-sulfated KS in total KS was significantly higher in all MPS patients younger than 5 years old, compared to age-matched controls. MPS I and VI patients treated with HSCT had normal levels of DS, and MPS I, VI, and VII treated with ERT or HSCT had normal levels of HS-0S and HS-NS, indicating that both treatments are effective in decreasing blood GAG levels. Conclusion Measurement of GAG levels in DBS is useful for diagnosis and potentially for monitoring the therapeutic efficacy in MPS. PMID:28065440
Rottinghaus, Erin; Bile, Ebi; Modukanele, Mosetsanagape; Maruping, Maruping; Mine, Madisa; Nkengasong, John; Yang, Chunfu
2013-01-01
Dried blood spots (DBS) collected onto filter paper have eased the difficulty of blood collection in resource-limited settings. Currently, Whatman 903 (W-903) filter paper is the only filter paper that has been used for HIV load and HIV drug resistance (HIVDR) testing. We therefore evaluated two additional commercially available filter papers, Ahlstrom grade 226 (A-226) and Munktell TFN (M-TFN), for viral load (VL) testing and HIVDR genotyping using W-903 filter paper as a comparison group. DBS specimens were generated from 344 adult patients on antiretroviral therapy (ART) in Botswana. The VL was measured with NucliSENS EasyQ HIV-1 v2.0, and genotyping was performed for those specimens with a detectable VL (≥ 2.90 log(10) copies/ml) using an in-house method. Bland-Altman analysis revealed a strong concordance in quantitative VL analysis between W-903 and A-226 (bias = -0.034 ± 0.246 log(10) copies/ml [mean difference ± standard deviation]) and W-903 and M-TFN (bias = -0.028 ± 0.186 log(10) copies/ml) filter papers, while qualitative VL analysis for virological failure determination, defined as a VL of ≥ 3.00 log(10) copies/ml, showed low sensitivities for A-266 (71.54%) and M-TFN (65.71%) filter papers compared to W-903 filter paper. DBS collected on M-TFN filter paper had the highest genotyping efficiency (100%) compared to W-903 and A-226 filter papers (91.7%) and appeared more sensitive in detecting major HIVDR mutations. DBS collected on A-226 and M-TFN filter papers performed similarly to DBS collected on W-903 filter paper for quantitative VL analysis and HIVDR detection. Together, the encouraging genotyping results and the variability observed in determining virological failure from this small pilot study warrant further investigation of A-226 and M-TFN filter papers as specimen collection devices for HIVDR monitoring surveys.
Microsample analyses via DBS: challenges and opportunities.
Henion, Jack; Oliveira, Regina V; Chace, Donald H
2013-10-01
The use of DBS is an appealing approach to employing microsampling techniques for the bioanalysis of samples, as has been demonstrated for the past 50 years in the metabolic screening of metabolites and diseases. In addition to its minimally invasive sample collection procedures and its economical merits, DBS microsampling benefits from the very high sensitivity, selectivity and multianalyte capabilities of LC-MS, which has been especially well demonstrated in newborn screening applications. Only a few microliters of a biological fluid are required for analysis, which also translates to significantly reduced demands on clinical samples from patients or from animals. Recently, the pharmaceutical industry and other arenas have begun to explore the utility and practicality of DBS microsampling. This review discusses the basis for why DBS techniques are likely to be part of the future, as well as offering insights into where these benefits may be realized.
Evaluation of blood collection filter papers for HIV-1 DNA PCR.
Masciotra, Silvina; Khamadi, Samoel; Bilé, Ebi; Puren, Adrian; Fonjungo, Peter; Nguyen, Shon; Girma, Mulu; Downing, Robert; Ramos, Artur; Subbarao, Shambavi; Ellenberger, Dennis
2012-10-01
The collection of dried blood spots (DBS) on Whatman 903 cards has facilitated for years the detection of HIV-1 in infants by DNA PCR as early as 4-6 weeks after birth in resource-limited settings (RLS), but alternate blood collection devices are proving to be necessary. The qualitative detection of HIV-1 DNA by PCR from DBS prepared on three commercially available blood collection cards was evaluated at the Centers for Disease Control and Prevention (CDC) and in four laboratories in Africa. DBS were prepared on Ahlstrom grade 226, Munktell TFN and Whatman 903, and stored under a variety of conditions. DBS were stored at ambient temperature (RT), 37°C with high humidity, and -20°C for varying lengths of time. The presence of HIV-1 DNA was tested using Roche Amplicor HIV-1 DNA (v 1.5) weekly for 4 weeks and at weeks 8 and 12 (RT and 37°C), at weeks 4, 8, and 18 (-20°C) of storage. DBS specimens were also tested after international shipment at RT. In addition, after nearly 3 years storage at -20°C, DBS were also evaluated independently using the COBAS Ampliprep/TaqMan HIV-1 Qual and Abbott RealTime HIV-1 Qualitative tests. HIV-1 DNA was detected equally well on the three blood collection cards regardless of storage conditions and PCR assay. Ahlstrom 226 and Munktell TFN papers were comparable to Whatman 903 for HIV-1 DNA detection and may be considered as optional blood collection devices in resource-limited countries. Published by Elsevier B.V.
Diagnosis of Morquio Syndrome in Dried Blood Spots Based on a New MRM-MS Assay.
Cozma, Claudia; Eichler, Sabrina; Wittmann, Gyula; Flores Bonet, Alba; Kramp, Guido Johannes; Giese, Anne-Katrin; Rolfs, Arndt
2015-01-01
Mucopolysaccharidosis IVA (MPS IVA; Morquio A disease) is an autosomal recessive disease caused and characterized by a decreased activity of N-acetylgalactosamine-6-sulfate sulfatase (GALNS), resulting in accumulation of keratan sulfate and chondroitin-6-sulfate in tissues and secondary organ damage. Recently approved enzyme replacement therapy renders the easy and early identification of MPS IVA of out-most importance. We propose a completely new assay for the stable and reproducible detection of GALNS deficiency in dry blood spots (DBS). For the validation blood samples were taken from 59 healthy individuals and 24 randomly selected genetically confirmed MPS IVA patients. The material extracted from DBS was incubated with a 4-methylumbelliferyl-β-D-galactopyranoside-6-sulfate as a specific substrate. Final enzymatic product, 4-methylumbelliferone, obtained after adding exogenous beta-galactosidase, was quantified by LC/MRM-MS (liquid-chromatography/multiple-reaction-monitoring mass-spectrometry). 4-propyl-5-hydroxy-7-methyl-2h-chromen-2-one was used as internal standard, a compound with a similar molecular structure and fragmentation pattern in negative ion mode as 4-methylumbelliferone. The enzymatic assay yielded a positive and negative predictive value of 1.0 for genetically confirmed MPS IVA patients (GALNS activity of 0.35 ± 0.21 μmol/L/h) and for controls with normal GALNS activity (23.1 ± 5.3 μmol/L /h). With present enzymatic conditions, the reaction yield in dried blood spots is at least 20 fold higher than any previously reported data with other assays. The present LC/MRM-MS based assay for MPS IVA diagnosis provides an easy, highly-standardized, accurate and innovative quantification of the enzymatic product in vitro and distinguishes perfectly between MPS IVA affected patients and normal controls. This technique will significantly simplify the early detection of MPS IVA patients.
Bobillo Lobato, Joaquin; Sánchez Peral, Blas A; Durán Parejo, Pilar; Jiménez Jiménez, Luis M
2013-03-15
Pompe disease, or acid maltase deficiency, is a genetic muscle disorder caused by mutations in the gene encoding the acid alpha-glucosidase (GAA) enzyme, which is essential for the degradation of glycogen to glucose in lysosomes. The wide clinical variability is resulted from genetic heterogeneity, and many different mutations of the GAA gene have been reported. Some of these mutations are associated with specific phenotypes, such as the c. -32T>G (IVS1-13T>G) mutation seen in late-onset Pompe disease. We used a real-time PCR, after genomic DNA extraction isolated from DBS (dried blood spots) and PCR amplification. Our results successfully detected in controls and patients have been 100% concordant with sequencing results. This assay combines simple sample processing and rapid analysis and it allows to detect the patients with a milder form and slower progression of this disease with a high reliability. Copyright © 2013 Elsevier B.V. All rights reserved.
Kantor, Rami; DeLong, Allison; Balamane, Maya; Schreier, Leeann; Lloyd, Robert M; Injera, Wilfred; Kamle, Lydia; Mambo, Fidelis; Muyonga, Sarah; Katzenstein, David; Hogan, Joseph; Buziba, Nathan; Diero, Lameck
2014-01-01
Antiretroviral resistance leads to treatment failure and resistance transmission. Resistance data in western Kenya are limited. Collection of non-plasma analytes may provide additional resistance information. We assessed HIV diversity using the REGA tool, transmitted resistance by the WHO mutation list and acquired resistance upon first-line failure by the IAS-USA mutation list, at the Academic Model Providing Access to Healthcare (AMPATH), a major treatment programme in western Kenya. Plasma and four non-plasma analytes, dried blood-spots (DBS), dried plasma-spots (DPS), ViveST(TM)-plasma (STP) and ViveST-blood (STB), were compared to identify diversity and evaluate sequence concordance. Among 122 patients, 62 were treatment-naïve and 60 treatment-experienced; 61% were female, median age 35 years, median CD4 182 cells/µL, median viral-load 4.6 log10 copies/mL. One hundred and ninety-six sequences were available for 107/122 (88%) patients, 58/62 (94%) treatment-naïve and 49/60 (82%) treated; 100/122 (82%) plasma, 37/78 (47%) attempted DBS, 16/45 (36%) attempted DPS, 14/44 (32%) attempted STP from fresh plasma and 23/34 (68%) from frozen plasma, and 5/42 (12%) attempted STB. Plasma and DBS genotyping success increased at higher VL and shorter shipment-to-genotyping time. Main subtypes were A (62%), D (15%) and C (6%). Transmitted resistance was found in 1.8% of plasma sequences, and 7% combining analytes. Plasma resistance mutations were identified in 91% of treated patients, 76% NRTI, 91% NNRTI; 76% dual-class; 60% with intermediate-high predicted resistance to future treatment options; with novel mutation co-occurrence patterns. Nearly 88% of plasma mutations were identified in DBS, 89% in DPS and 94% in STP. Of 23 discordant mutations, 92% in plasma and 60% in non-plasma analytes were mixtures. Mean whole-sequence discordance from frozen plasma reference was 1.1% for plasma-DBS, 1.2% plasma-DPS, 2.0% plasma-STP and 2.3% plasma-STB. Of 23 plasma-STP discordances, one mutation was identified in plasma and 22 in STP (p<0.05). Discordance was inversely significantly related to VL for DBS. In a large treatment programme in western Kenya, we report high HIV-1 subtype diversity; low plasma transmitted resistance, increasing when multiple analytes were combined; and high-acquired resistance with unique mutation patterns. Resistance surveillance may be augmented by using non-plasma analytes for lower-cost genotyping in resource-limited settings.
Höppner, Sebastian; Delahaut, Philippe; Schänzer, Wilhelm; Thevis, Mario
2014-01-01
The NAD(+) depending enzyme SIRT1 regulates the mitochondrial biogenesis, fat and glucose metabolism through catalyzing the deacetylation of several metabolism-related protein-substrates. Recently, synthetic activators of SIRT1 referred to as STACs (Sirtuin activating compounds, e.g. SRT2104) were identified and tested in clinical studies for the treatment of aging-related diseases such as type 2 diabetes, Alzheimer's and obesity. Although the mechanism of SIRT1 activation by small molecules has caused considerable controversy, STACs demonstrated a significant performance enhancement in mice experiments including an improvement of endurance, muscle strength, and locomotor behavior. Due to their potential to increase exercise tolerance in healthy individuals, SIRT1 activators are currently being monitored by anti-doping authorities. In the present study, the in vivo metabolic clearance of three SIRT1 activators was investigated in rats by the collection of urine, DBS (dried blood spots) and plasma samples following a single oral administration. The resulting metabolic products were studied by positive electrospray ionization - (tandem) mass spectrometry and confirmed by the comparison with in vitro generated metabolites using human and rat liver microsomal preparations. Subsequently, a screening procedure for five SIRT1 activators and the metabolite M1-SRT1720 in DBS specimens was developed. Liquid-liquid-extraction and liquid chromatography/tandem mass spectrometry was employed based on diagnostic ion transitions recorded in multiple reaction monitoring mode and two deuterated internal standards namely d8-SRT1720 and d8-M1-SRT1720 were utilized. The doping control assay was characterized with regard to specificity, limit of detection (10-50ng/ml), recovery (65-83%) and imprecision (7-20%) and ion suppression/enhancement effects (<10%), demonstrating its fitness-for-purpose for sports drug testing applications. Copyright © 2013 Elsevier B.V. All rights reserved.
Bakhireva, Ludmila N; Sharkis, Janet; Shrestha, Shikhar; Miranda-Sohrabji, Tristan J; Williams, Sonnie; Miranda, Rajesh C
2017-05-01
While 2 to 5% of school-aged children in the United States are estimated to be affected by fetal alcohol spectrum disorders (FASD), the prevalence of prenatal alcohol exposure (PAE) might be substantially underreported. Our objective was to systematically estimate the prevalence of PAE in Texas by measuring a direct ethanol metabolite, phosphatidylethanol (PEth), in 1,000 infant residual dried blood spots (irDBSs) in the Texas Newborn Screening Repository. All public health regions (PHRs) were represented proportional to their 2014 birth rate (~0.25% of total births). A cross-sectional study design (unit of observation: individual irDBS cards/infants) with additional ecologic subanalysis (unit of observation: aggregate measures for each Texas PHR) was utilized. The study used PEth-irDBS to estimate the prevalence of PAE within 1 month before delivery for the state of Texas and each Texas PHR. The ecologic subanalysis compared different geographical regions' aggregate prevalence of PAE with (i) retail liquor licenses, (ii) median household income by PHR, and (iii) prevalence of birth outcomes commonly associated with FASD. The sample included an equal number of males and females; 47.8% non-Hispanic White, 40.8% Hispanic, 6.6% African American, and 4.8% Asian infants. In the entire sample, 8.4% of irDBSs were positive for PEth (>20 ng/ml) indicative of PAE within approximately 1 month before delivery. Large regional differences were observed with mostly urban, high median-income regions demonstrating the highest prevalence. Results of this first systematic statewide PAE prevalence study demonstrate that PAE might be more prevalent than previously thought. Active case ascertainment efforts for FASD coupled with systematic objective assessment of PAE should expand to the national level to better estimate public health needs required to provide adequate services for children affected by PAE. Copyright © 2017 by the Research Society on Alcoholism.
Automated DBS microsampling, microscale automation and microflow LC-MS for therapeutic protein PK.
Zhang, Qian; Tomazela, Daniela; Vasicek, Lisa A; Spellman, Daniel S; Beaumont, Maribel; Shyong, BaoJen; Kenny, Jacqueline; Fauty, Scott; Fillgrove, Kerry; Harrelson, Jane; Bateman, Kevin P
2016-04-01
Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.
Glucose-6-phosphate dehydrogenase enzyme stability in filter paper dried blood spots.
Flores, Sharon R; Hall, Elizabeth M; De Jesús, Víctor R
2017-10-01
Prior to initial distribution of Glucose-6-phosphate dehydrogenase (G6PD) proficiency testing (PT) materials, we evaluated G6PD enzyme stability in dried blood spots (DBS) under various temperature and humidity environments to develop storage and usage guidelines for our new materials. We prepared fresh G6PD-normal DBS materials and conducted stability evaluations of daily use and short and long-term storage under various temperature and humidity environments. G6PD DBS PT materials retained 92% of initial activity after 30days of use at 4°C. Materials stored at -20°C and 4°C with desiccant for 30days retained 95% and 90% of initial activity, respectively. When stored for one year at -20°C or six months at 4°C specimens retained >90% of initial activity. Specimens stored at 37°C with desiccant lost 10% activity in three days. At the end of 30days, specimens stored under 'Extreme'-humidity >50% without desiccant- conditions at 37°C assayed below the NSQAP cut off for G6PD. Humidity exacerbated loss of enzyme activity with increasing temperature and time duration. Data suggest that G6PD PT materials can be stored at 4°C and used for up to one month and can be stored at -20°C for one year and yield >90% enzyme activity. Exposure to warm temperatures, especially with elevated humidity, should be avoided. Desiccant should always be used to mitigate humidity effects. Published by Elsevier Inc.
Steve, Ahuka-Mundeke; Ahidjo, Ayouba; Placide, Mbala-Kingebeni; Caroline, Foncelle; Mukulumanya, Mubonga; Simon-Pierre, Ndimbo-Kumugo; Octavie, Lunguya-Metila; Valentin, Mbenzo-Abokome; Jean-Jacques, Muyembe-Tamfum; Eric, Delaporte; Martine, Peeters
2017-01-01
Like the majority of emerging infectious diseases, HIV and HTLV are of zoonotic origin. Here we assess the risk of cross-species transmissions of their simian counterparts, SIV and STLV, from nonhuman primates (NHP) to humans in the Democratic Republic of Congo (DRC). A total of 331 samples, derived from NHP bushmeat, were collected as dried blood spots (DBS, n=283) or as tissue samples (n=36) at remote forest sites in northern and eastern DRC. SIV antibody prevalences in DBS were estimated with a novel high throughput immune assay with antigens representing the actual known diversity of HIV/SIV lineages. Antibody positive samples were confirmed by PCR and sequence analysis. Screening for STLV infection was done with universal primers in tax and new strains were further characterized in LTR. SIV and STLV infection in tissue samples was done by PCR only. Overall, 5% and 15.4% of NHP bushmeat was infected with SIV and STLV respectively. A new SIV lineage was identified in Allen's swamp monkeys (Allenopithecus nigroviridis). Three new STLV-1 subtypes were identified in Allen's swamp monkeys (Allenopithecus nigroviridis), blue monkeys (Cercopithecus mitis), red tailed guenons (Cercopithecus ascanius schmidti) and agile mangabeys (Cercocebus agilis). SIV and STLV prevalences varied according to species and geographic region. Our study illustrates clearly, even on a small sample size from a limited number of geograhic areas, that our knowledge on the genetic diversity and geographic distribution of simian retroviruses is still limited and that humans continue to be exposed to relative high proportions on infected NHP bushmeat. PMID:28050688
Hess, Sonja Y; Ouédraogo, Césaire T; Young, Rebecca R; Bamba, Ibrahim F; Stinca, Sara; Zimmermann, Michael B; Wessells, K Ryan
2017-05-01
To assess iodine status among pregnant women in rural Zinder, Niger and to compare their status with the iodine status of school-aged children from the same households. Seventy-three villages in the catchment area of sixteen health centres were randomly selected to participate in the cross-sectional survey. Salt iodization is mandatory in Niger, requiring 20-60 ppm iodine at the retail level. A spot urine sample was collected from randomly selected pregnant women (n 662) and one school-aged child from the same household (n 373). Urinary iodine concentration (UIC) was assessed as an indicator of iodine status in both groups. Dried blood spots (DBS) were collected from venous blood samples of pregnant women and thyroglobulin (Tg), thyroid-stimulating hormone and total thyroxine were measured. Iodine content of household salt samples (n 108) was assessed by titration. Median iodine content of salt samples was 5·5 ppm (range 0-41 ppm), 98 % had an iodine content 40 µg/l. In this region of Niger, most salt is inadequately iodized. UIC in pregnant women indicated iodine deficiency, whereas UIC of school-aged children indicated marginally adequate iodine status. Thus, estimating population iodine status based solely on monitoring of UIC among school-aged children may underestimate the risk of iodine deficiency in pregnant women.
Wang, Xiao-Hong; Zhang, Lin; Sperry, Laura; Olichney, John; Farias, Sarah Tomaszewski; Shahlaie, Kiarash; Chang, Norika Malhado; Liu, Ying; Wang, Su-Ping; Wang, Cui
2015-12-20
This review examines the evidence that deep brain stimulation (DBS) has extensive impact on nonmotor symptoms (NMSs) of patients with Parkinson's disease (PD). We retrieved information from the PubMed database up to September, 2015, using various search terms and their combinations including PD, NMSs, DBS, globus pallidus internus (GPi), subthalamic nucleus (STN), and ventral intermediate thalamic nucleus. We included data from peer-reviewed journals on impacts of DBS on neuropsychological profiles, sensory function, autonomic symptoms, weight changes, and sleep disturbances. For psychological symptoms and cognitive impairment, we tried to use more reliable proofs: Random, control, multicenter, large sample sizes, and long period follow-up clinical studies. We categorized the NMSs into four groups: those that would improve definitively following DBS; those that are not significantly affected by DBS; those that remain controversial on their surgical benefit; and those that can be worsened by DBS. In general, it seems to be an overall beneficial effect of DBS on NMSs, such as sensory, sleep, gastrointestinal, sweating, cardiovascular, odor, urological symptoms, and sexual dysfunction, GPi-DBS may produce similar results; Both STN and Gpi-DBS are safe with regard to cognition and psychology over long-term follow-up, though verbal fluency decline is related to DBS; The impact of DBS on behavioral addictions and dysphagia is still uncertain. As the motor effects of STN-DBS and GPi-DBS are similar, NMSs may determine the target choice in surgery of future patients.
NASA Astrophysics Data System (ADS)
Martin, Nicholas J.; Griffiths, Rian L.; Edwards, Rebecca L.; Cooper, Helen J.
2015-08-01
Liquid extraction surface analysis (LESA) mass spectrometry is a promising tool for the analysis of intact proteins from biological substrates. Here, we demonstrate native LESA mass spectrometry of noncovalent protein complexes of myoglobin and hemoglobin from a range of surfaces. Holomyoglobin, in which apomyoglobin is noncovalently bound to the prosthetic heme group, was observed following LESA mass spectrometry of myoglobin dried onto glass and polyvinylidene fluoride surfaces. Tetrameric hemoglobin [(αβ)2 4H] was observed following LESA mass spectrometry of hemoglobin dried onto glass and polyvinylidene fluoride (PVDF) surfaces, and from dried blood spots (DBS) on filter paper. Heme-bound dimers and monomers were also observed. The `contact' LESA approach was particularly suitable for the analysis of hemoglobin tetramers from DBS.
Silica Coated Paper Substrate for Paper-Spray Analysis of Therapeutic Drugs in Dried Blood Spots
Zhang, Zhiping; Xu, Wei; Manicke, Nicholas E.; Cooks, R. Graham; Ouyang, Zheng
2011-01-01
Paper spray is a newly developed ambient ionization method that has been applied for direct qualitative and quantitative analysis of biological samples. The properties of the paper substrate and spray solution have a significant impact on the release of chemical compounds from complex sample matrices, the diffusion of the analytes through the substrate, and the formation of ions for mass spectrometry analysis. In this study, a commercially available silica-coated paper was explored in an attempt to improve the analysis of therapeutic drugs in dried blood spots (DBS). The dichloromethane/isopropanol solvent has been identified as an optimal spray solvent for the analysis. The comparison was made with paper spray using chromatography paper as substrate with methanol/water as solvent for the analysis of verapamil, citalopram, amitriptyline, lidocaine and sunitinib in dried blood spots. It has been demonstrated the efficiency of recovery of the analytes was notably improved with the silica coated paper and the limit of quantitation (LOQ) for the drug analysis was 0.1 ng mL−1 using a commercial triple quadrupole mass spectrometer. The use of silica paper substrate also resulted in a sensitivity improvement of 5-50 fold in comparison with chromatography papers, including the Whatmann ET31 paper used for blood card. Analysis using a handheld miniature mass spectrometer Mini 11 gave LOQs of 10~20 ng mL−1 for the tested drugs, which is sufficient to cover the therapeutic ranges of these drugs. PMID:22145627
Liu, Jia-Ming; Gao, Fei; Huang, Hong-Hua; Zeng, Li-Qing; Huang, Xiao-Mei; Zhu, Guo-Hui; Li, Zhi-Ming
2008-04-01
Fullerenol (F) shows a strong and stable room-temperature phosphorescence (RTP) signal on the surface of nitrocellulose membrane (NCM) at lambda ex max/ lambda em max =542.0/709.4 nm. When modified by dodecylbenzenesulfonic acid sodium salt (DBS), fullerenol emits a stronger signal. It was also found that quantitative specific affinity-adsorption reaction can be carried out between Triticum vulgare lectin (WGA) labeled with DBS-F and alkaline phosphatase (ALP) on the surface of NCM, and the product obtained (WGA-ALP-WGA-F-DBS) emits a strong and stable RTP signal. Furthermore, the content of ALP was proportional to the DeltaI(p) value. Based on the facts above, a new method for the determination of trace amounts of ALP by affinity-adsorption solid-substrate room-temperature phosphorimetry (AA-SS-RTP) was established, using fullerenol modified with DBS to label WGA. The detection limit was 0.011 fg spot(-1) (corresponding concentration: 2.8x10(-14) g ml(-1), namely 2.8x10(-16) mol l(-1)). This method with high sensitivity, accuracy, and precision has been successfully applied to the determination of the content of ALP in human serum survey and forecast human disease, and the results are tallied with those using alkaline phosphatase kits. The mechanism for the determination of ALP using AA-SS-RTP was also discussed.
Moore, David M; Kanters, Steve; Michelow, Warren; Gustafson, Reka; Hogg, Robert S; Kwag, Michael; Trussler, Terry; McGuire, Marissa; Robert, Wayne; Gilbert, Mark
2012-01-01
We examined HIV prevalence, awareness of HIV serostatus and HIV risk behaviour among a sample of men who have sex with men (MSM) in Vancouver. MSM > or = 18 years were recruited from August 2008 to February 2009 through community venues. Participants completed a questionnaire and provided a dried blood spot (DBS) for HIV and other STI testing. We performed descriptive statistics and bivariate analyses of key explanatory variables. A total of 1,169 participants completed questionnaires; of these, 1,138 (97.3%) provided DBS specimens suitable for testing. The median age was 33 years (IQR 26-44). A total of 206 (18%) were HIV-positive by DBS, of whom 86% were aware they were positive. HIV seropositivity increased from 7.1% in those < 30 years of age to 19% in those 30-44 years and 34% among those > or = 45 years (p < 0.001 for test of trend). Of the 933 who self-reported as HIV-negative or unknown, 28 (3.0%) tested HIV-positive. Among those not tested for HIV in the previous 2 years, the reasons for not testing differed between participants with undiagnosed HIV infection and those who were HIV-negative. A total of 62% of study participants who self-reported as HIV-negative reported using a condom the last time they had anal sex. The use of risk-reduction measures was reported by 91.1% of all study participants (72% if excluding consistent condom use). The majority of MSM in Vancouver have adopted behaviours that reduce their HIV-related risk. However, prevention programs must continue to promote condom use, increase HIV testing, and better inform MSM of the value and limitations of other risk-reduction strategies.
Sgaier, S K; Mony, P; Jayakumar, S; McLaughlin, C; Arora, P; Kumar, R; Bhatia, P; Jha, P
2011-03-01
To determine the prevalence and correlates of Herpes Simplex Virus-2 (HSV-2) and syphilis infections in the general population in India. 2456 adults were surveyed in Hyderabad, Bangalore and Chandigarh in India. Socio-demographic and lifestyle characteristics were obtained through a questionnaire, and a dried blood spot (DBS) was collected from all individuals aged 18 years and over; sexual behaviour was collected from those aged 18-49 years. DBS samples were tested for HSV-2 and syphilis serology. The association between HSV-2 and syphilis infections with socio-demographic and behavioural variables was analysed using multivariable logistic regression. The prevalence of HSV-2 and syphilis was 10.1% and 1.7%, respectively. Geographic differences in HSV-2 prevalence were significant, while for syphilis it was comparable. Urban-rural differences in prevalence were only seen for syphilis. For both infections, the prevalence between males and females was not significantly different. In males and females, HSV-2 prevalence increased significantly with increasing age; for syphilis, a slight trend was seen only in females. In a multivariable analysis, HSV-2 infection in males and females was associated with site, religion and testing positive for syphilis, in addition to reporting ≥ 2 lifetime partners in the previous year among males and being ever married or having had sex with a non-regular partner in the last year among females. The burden and geographic heterogeneity of HSV-2 and syphilis infections in India are significant. A national household and DBS-based sexually transmitted infection (STI) surveillance system would enable monitoring, especially in relation to the HIV epidemic, and planning of evidence-based prevention and treatment programmes.
Wang, Xiao-Hong; Zhang, Lin; Sperry, Laura; Olichney, John; Farias, Sarah Tomaszewski; Shahlaie, Kiarash; Chang, Norika Malhado; Liu, Ying; Wang, Su-Ping; Wang, Cui
2015-01-01
Objective: This review examines the evidence that deep brain stimulation (DBS) has extensive impact on nonmotor symptoms (NMSs) of patients with Parkinson's disease (PD). Data Sources: We retrieved information from the PubMed database up to September, 2015, using various search terms and their combinations including PD, NMSs, DBS, globus pallidus internus (GPi), subthalamic nucleus (STN), and ventral intermediate thalamic nucleus. Study Selection: We included data from peer-reviewed journals on impacts of DBS on neuropsychological profiles, sensory function, autonomic symptoms, weight changes, and sleep disturbances. For psychological symptoms and cognitive impairment, we tried to use more reliable proofs: Random, control, multicenter, large sample sizes, and long period follow-up clinical studies. We categorized the NMSs into four groups: those that would improve definitively following DBS; those that are not significantly affected by DBS; those that remain controversial on their surgical benefit; and those that can be worsened by DBS. Results: In general, it seems to be an overall beneficial effect of DBS on NMSs, such as sensory, sleep, gastrointestinal, sweating, cardiovascular, odor, urological symptoms, and sexual dysfunction, GPi-DBS may produce similar results; Both STN and Gpi-DBS are safe with regard to cognition and psychology over long-term follow-up, though verbal fluency decline is related to DBS; The impact of DBS on behavioral addictions and dysphagia is still uncertain. Conclusions: As the motor effects of STN-DBS and GPi-DBS are similar, NMSs may determine the target choice in surgery of future patients. PMID:26668154
Dwivedi, Jaya; Namdev, Kuldeep K; Chilkoti, Deepak C; Verma, Surajpal; Sharma, Swapnil
2018-06-06
Therapeutic drug monitoring (TDM) of anti-epileptic drugs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) is a suitable alternative to overcome these issues. An improved, simple, rapid, and stability indicating method for quantification of pregabalin in human plasma and DPS has been developed and validated. Analyses were performed on liquid chromatography tandem mass spectrometer under positive ionization mode of electrospray interface. Pregabain-d4 was used as internal standard, and the chromatographic separations were performed on Poroshell 120 EC-C18 column using an isocratic mobile phase flow rate of 1 mL/min. Stability of pregabalin in DPS was evaluated under simulated real-time conditions. Extraction procedures from plasma and DPS samples were compared using statistical tests. The method was validated considering the FDA method validation guideline. The method was linear over the concentration range of 20-16000 ng/mL and 100-10000 ng/mL in plasma and DPS, respectively. DPS samples were found stable for only one week upon storage at room temperature and for at least four weeks at freezing temperature (-20 ± 5 °C). Method was applied for quantification of pregabalin in over 600 samples of a clinical study. Statistical analyses revealed that two extraction procedures in plasma and DPS samples showed statistically insignificant difference and can be used interchangeably without any bias. Proposed method involves simple and rapid steps of sample processing that do not require a pre- or post-column derivatization procedure. The method is suitable for routine pharmacokinetic analysis and therapeutic monitoring of pregabalin.
D'Apolito, Oceania; Garofalo, Daniela; la Marca, Giancarlo; Dello Russo, Antonio; Corso, Gaetano
2012-02-01
Orotic acid (OA), a marker of hereditary orotic aciduria, is usually used for the differential diagnosis of some hyperammonemic inherited defects of urea cycle and of basic amino acid transporters. This study was aimed to establish age related reference intervals of OA in urine, and for the first time in plasma, and dried blood spot (DBS) from 229 apparently healthy subjects aged from three days to 40 years. The quantification of OA was performed by a previously implemented method, using a stable isotope dilution with 1,3-[(15)N(2)]-orotic acid and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS). The method has proved to be sensitive and accurate for a quantitative analysis of OA also in DBS and plasma. According to previous studies, urinary OA levels (mmol/mol of creatinine) decrease significantly with age. The upper limits (as 99th %ile) were of 3.44 and 1.30 in groups aged from three days to 1 year (group 1) and from 1 year to 12 years (group 2), respectively; in teenagers (from 13 to 19 years; group 3) and adults (from 20 to 40 years; group 4) urinary levels became more stable and the upper limits were of 0.64 and 1.21, respectively. Furthermore, OA levels in DBS (μM) also resulted significantly higher in subjects of group 1 (upper limit of 0.89) than in subjects of groups 2, 3 and 4 (upper limits of 0.24, 0.21, and 0.29, respectively). OA levels in plasma (μM) were significantly lower in subjects of group 3 (upper limit of 0.30) than in subjects of groups 1, 2, and 4 (upper limits of 0.59, 0.48, and 0.77, respectively). This method was also employed for OA quantification in plasma and DBS of 17 newborns affected by urea cycle defects, resulting sensitive and specific enough to screen these disorders. Copyright © 2011 Elsevier B.V. All rights reserved.
Yu, Chaowen; Huang, Shuodan; Wang, Ming; Zhang, Juan; Liu, Hao; Yuan, Zhaojian; Wang, Xingbin; He, Xiaoyan; Wang, Jie; Zou, Lin
2017-02-10
Traditional methods for thalassemia screening are time-consuming and easily affected by cell hemolysis or hemoglobin degradation in stored blood samples. Tandem mass spectrometry (MS/MS) proved to be an effective technology for sickle cell disorders (SCD) screening. Here, we developed a novel MS/MS method for β-thalassemia screening from dried blood spots (DBS). Stable isotopic-labeled peptides were used as internal standards for quantification and calculation of the α:β-globin ratios. We used the α:β-globin ratio cutoffs to differentiate between normal individuals and patients with thalassemia. About 781 patients and 300 normal individuals were analyzed. The α:β-globin ratios showed significant difference between normal and β-thalassemia patients (P<0.01), particularly when the disease was homozygous or double heterozygous with another α- or β-thalassemia mutation. In the parallel study, all cases screened for suspected thalassemia from six hundred DBS samples by using this MS/MS method were successfully confirmed by genotyping. The intra-assay and inter-assay CVs of the ratios ranged from 2.4% to 3.9% and 4.7% to 7.1%, and there was no significant sample carryover or matrix effect for this MS/MS method. Combined with SCD screening, this MS/MS method could be used as a first-line screening assay for both structural and expression abnormalities of human hemoglobin. Traditional methods for thalassemia screening were depending on the structural integrity of tetramers and could be affected by hemolysis and degradation of whole blood samples, especially when stored. We used proteospecific peptides produced by the tryptic digestion of each globin to evaluate the production ratio between α- and β-globin chains, which turned out to be quite stable even when stored for more than two months. Though most of the peptides were specific to α-globin or β-globin, we only chose four most informative peptides and its stable isotopic-labeled peptides as internal standards for analysis, which could obtain a high accuracy. Currently, we are the first to address the application of MS/MS for thalassemia screening, when combined with SCD screening, this MS/MS method could be used as a first-line screening assay for both structural and expression abnormalities of human hemoglobin. Copyright © 2016. Published by Elsevier B.V.
Namdev, Kuldeep Kumar; Dwivedi, Jaya; Chilkoti, Deepak Chandra; Sharma, Swapnil
2018-01-01
Lamotrigine (LTZ) is a phenyltriazine derivative which belongs to anti-epileptic drugs (AEDs) class and prescribed as mono- or adjunctive-therapy in treatment of epilepsy. Therapeutic drug monitoring (TDM) of AEDs provides a valid clinical tool in optimization of overall therapy. However, TDM is challenging due to the high biological samples (plasma/blood) storage/shipment costs and the limited availability of laboratories providing TDM services. Sampling in the form of dry plasma spot (DPS) or dry blood spot (DBS) are suitable alternative to overcome these issues. We developed and validated a new method for quantification of LTZ in human plasma and DPS. The extraction of LTZ from plasma and DPS was performed using liquid-liquid extraction with diethyl ether and an extraction solution composed of diethyl ether- methyl tert-butyl ether- acetone (50:30:20, v/v/v), respectively. Lamotrigine- 13C3, d3 was used as internal standard (ISTD) and the chromatographic separation was achieved on Hypurity Advance C18 column (150×4.6mm, 5μm). Quantitative estimation of LTZ and ISTD was performed on a liquid chromatography tandem mass spectrometer coupled with electrospray ionization interface operated under positive mode of ionization. Calibration curves were linear (r 2 >0.99) over the concentration range of 10-3020ng/mL for both plasma and DPS. Statistical analysis provides insignificant difference between LTZ concentration extracted from plasma and DPS samples. The method is found suitable for application in clinical study and in therapeutic monitoring of LTZ. To the best of our knowledge this is the first report which describing a validated stability indicating assay for quantification of LTZ in dry plasma spot. Copyright © 2017 Elsevier B.V. All rights reserved.
Mumps transmission in social networks: a cohort study.
Hahné, Susan; Schurink, Tessa; Wallinga, Jacco; Kerkhof, Jeroen; van der Sande, Marianne; van Binnendijk, Rob; de Melker, Hester
2017-01-10
Mumps emerged among highly vaccinated populations in the Netherlands. This offered a unique opportunity to study mumps virus transmission. In particular the extent to which asymptomatic infections in vaccinated people contribute to ongoing mumps virus transmission is uncertain. Insight into this could help project the future burden of mumps in vaccinated populations. We therefore studied the relative infectiousness of symptomatic and asymptomatic cases. In a cohort study we followed contacts of notified mumps cases (ring 1) and contacts' contacts (ring 2) for 40 days to ascertain symptoms of mumps and social contacts by weekly diaries and questionnaires, and mumps virus infections by taking finger stick dried blood spot specimens (DBS) that were tested for mumps-specific IgG antibodies. Mumps IgG concentrations >1500 RU/ml in a single sample, a four-fold increase in IgG antibody concentration in paired samples, or a positive oral fluid PCR were defined as recent infection. We recruited 99 contacts (40 in ring 1 and 59 in ring 2) of 10 mumps index cases. The median age of participants was 23 years (range 18-57 years), 31 (31%) were male. At study entry, DBS of 4 out of 78 (5%) participants with samples showed serological evidence of recent mumps virus infection. Three of these reported mumps symptoms. Among the 59 participants who provided DBS at the beginning and end of the follow-up period, none had serological evidence of infection during this period. Of 72 participants who provided at least one oral fluid sample, one participant (1%) who also reported mumps symptoms, was found PCR positive. Of all 99 participants, the attack rate of self-reported mumps was 4% (95% CI 1.1-10.0%). Of the 5 laboratory confirmed mumps cases, 1 reported no mumps symptoms (percentage asymptomatic 20% (95% CI 0-71%)). Compared to non-students, students had larger households and more household members who were born after 1980 (p < 0.01 and <0.01, respectively). We demonstrated that this prospective cohort study design allows for inference of the proportion of asymptomatic mumps infections. Because we only detected one asymptomatic mumps virus infection, we could not assess the relative infectiousness of asymptomatic mumps. Household characteristics of students differed from non-students. This may partly explain recent mumps epidemiology in the Netherlands.
Rello, Luis; Aramendía, Maite; Belarra, Miguel A; Resano, Martín
2015-01-01
DBS have become a clinical specimen especially adequate for establishing home-based collection protocols. In this work, high-resolution continuum source graphite furnace atomic absorption spectrometry is evaluated for the direct monitoring of Pb in DBS, both as a quantitative tool and a screening method. The development of the screening model is based on the establishment of the unreliability region around the threshold limits, 100 or 50 μg l(-1). More than 500 samples were analyzed to validate the model. The screening method demonstrated high sensitivity (the rate of true positives detected was always higher than 95%), an excellent LOD (1 µg l(-1)) and high throughput (10 min per sample).
Olchik, Maira Rozenfel; Ghisi, Marciéle; Ayres, Annelise; Schuh, Arthur Francisco Shumacher; Oppitz, Paulo Petry; Rieder, Carlos Roberto de Mello
2018-01-01
Introduction Deep brain stimulation (DBS) is an established treatment for Parkinson's disease (PD). However, there is little evidence regarding the effect of DBS on dysphagia. Objective To assess the swallowing and quality of life of individuals with PD before and after DBS surgery. Methods Our sample consisted of people who had undergone DBS surgery in a referral hospital in the state of Rio Grande do Sul, Brazil. The inclusion criteria were a diagnosis of PD and having undergone DBS surgery. A cognitive screening, through a questionnaire about depression and quality of life, was conducted. Evaluations of each patient's swallowing were performed before and after surgery. The assessment consisted of anamnesis, clinical assessment, the Functional Oral Intake Scale, clinical evaluation of swallowing, and the Hoehn and Yahr scale. Results The sample included 10 individuals, all male, with a mean age of 57.3 years (±4.7), a mean disease duration of 13.0 years (±2.4), and mean level education of 8.1 years (±4.0). In the clinical evaluation of the swallowing, a significant improvement after DBS was not observed. However, little changes in the signs and symptoms of dysphagia that had a positive impact on the quality of life were observed. Furthermore, there was no relation between the patients' motor subtype and swallowing pre- and post-DBS. Conclusion There was an improvement in the quality of life of the patients after DBS. However, the improvement in the clinical signs and symptoms of dysphagia did not cause an overall improvement in the swallowing function. PMID:29619099
Huang, Chuyi; Chu, Heling; Zhang, Yan; Wang, Xiaoping
2018-01-01
Freezing of gait (FOG) is a gait disorder featured by recurrent episodes of temporary gait halting and mainly found in advanced Parkinson's disease (PD). FOG has a severe impact on the quality of life of patients with PD. The pathogenesis of FOG is unclear and considered to be related to several brain areas and neural circuits. Its close connection with cognitive disorder has been proposed and some researchers explain the pathogenesis using the cognitive model theory. FOG occurs concurrently with cognitive disorder in some PD patients, who are poorly responsive to medication therapy. Deep brain stimulation (DBS) proves effective for FOG in PD patients. Cognitive impairment plays a role in the formation of FOG. Therefore, if DBS works by improving the cognitive function, both two challenging conditions can be ameliorated by DBS. We reviewed the clinical studies related to DBS for FOG in PD patients over the past decade. In spite of the varying stimulation parameters used in different studies, DBS of either subthalamic nucleus (STN) or pedunculopontine nucleus (PPN) alone or in combination can improve the symptoms of FOG. Moreover, the treatment efficacy can last for 1-2 years and DBS is generally safe. Although few studies have been conducted concerning the use of DBS for cognitive disorder in FOG patients, the existing studies seem to indicate that PPN is a potential therapeutic target to both FOG and cognitive disorder. However, most of the studies have a small sample size and involve sporadic cases, so it remains uncertain which nucleus is the optimal target of stimulation. Prospective clinical trials with a larger sample size are needed to systematically assess the efficacy of DBS for FOG and cognitive disorder.
Quantification of total hexose on dry blood spot by tandem mass spectrometry.
Gong, Zhenhua; Tian, Guoli; Huang, Qiwei; Wang, Yanmin; Ge, Qingwei
2012-12-01
Because hypoglycemia and hyperglycemia are harmful and not always associated with overt clinical signs, it is necessary to have methods available to screen for glucose levels to detect hypoglycemia and diabetes as early as possible. A new method for such screening and the clinical determination of blood total hexose on a dry blood spot (DBS) using tandem mass spectrometry (MS/MS) was developed. The serum glucose controls and blood were prepared as DBS and then extracted into a methanol solution containing isotope-labeled internal standards. The methanolic extraction was subjected to HPLC, followed by MS/MS in positive ion mode. Multiple-reaction monitoring of m/z 203.1→23 was used to detect hexose, and m/z 209.0→23 was used for 13C6-D-glucose. The recoveries of blood glucose by MS/MS were 90%-102% with an R(2) value of 0.999 after linear regression (p<0.001). The controls were within an acceptable range, and the coefficients of variation were less than 10%. The blood total hexose in neonates aged 3-7 days (6.41±1.46 mmol/L) was lower than that in neonates aged 8-30 days (6.66±1.38 mmol/L), and it was lower in neonates than in children aged 1-72 months (7.19±1.87 mmol/L). Quantification of total hexose on a dry blood spot by MS/MS is accurate, reliable and feasible for screening and clinical tests. Copyright © 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.
Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B
2017-04-01
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
De Silva, Veronica; Oldham, Charlie D; May, Sheldon W
2010-09-01
Phenylketonuria (PKU) is an autosomal recessive disorder caused by an impaired conversion of L-phenylalanine (Phe) to L-tyrosine, typically resulting from a deficiency in activity of a hepatic and renal enzyme L-phenylalanine hydroxylase. The disease is characterized by an increased concentration of Phe and its metabolites in body fluids. A modified assay based on an enzymatic-colorimetric methodology was developed for measuring blood Phe levels in PKU patients; this method is designed for use with undeproteinized samples and avoids the use of solvents or amphiphilic agents. Thus, the method could be suitable for incorporation into a simple home-monitoring device. We report here on a comparison of blood Phe concentrations in PKU patients measured in undeproteinized plasma using this enzyme colorimetric assay (ECA), with values determined by amino acid analysis (AAA) of deproteinized samples, and HPLC and tandem mass spectrometry (MS/MS) analyses of dried blood spot (DBS) eluates. Pearson correlation coefficients of 0.951, 0.976 and 0.988 were obtained when AAA-measured Phe concentrations were compared with the ECA-, HPLC- or MS/MS-measured values, respectively. A Bland-Altman analysis revealed that mean Phe concentrations determined using AAA were on average 65 μmol/L lower than values measured by our ECA. These results may be the result of minimizing the manipulations performed on the patient sample compared with AAA, HPLC, and MS/MS methods, which involve plasma deproteinization or DBS elution and derivatization. The results reported here confirm that Phe concentrations determined by our ECA method are comparable to those determined by other widely used methods for a broad range of plasma Phe concentrations.
Händel, Mina Nicole; Frederiksen, Peder; Cohen, Arieh; Cooper, Cyrus; Heitmann, Berit Lilienthal; Abrahamsen, Bo
2017-07-01
Background: Whether antenatal and neonatal vitamin D status have clinical relevance in fracture prevention has not been examined extensively, although observational studies indicate that fetal life may be a sensitive period in relation to bone growth and mineralization during childhood. Objective: We examined whether 25-hydroxyvitamin D 3 [25(OH)D 3 ] concentrations in stored neonatal dried blood spot (DBS) samples are associated with pediatric fracture risk. We hypothesized that in particular, low neonatal vitamin D status may be a risk factor for fracture incidence among children. Design: In a register-based case-cohort study design, the case group was composed of 1039 individuals who were randomly selected from a total of 82,154 individuals who were born during 1989-1999 and admitted to a Danish hospital with a fracture of the forearm, wrist, scaphoid bone, clavicle, or ankle at age 6-13 y. The subcohort was composed of 1600 individuals randomly selected from all Danish children born during 1989-1999. The neonatal 25(OH)D 3 concentrations in DBS samples were assessed by using highly sensitive chromatography-tandem mass spectrometry. Results: The mean ± SD 25(OH)D 3 concentration for all subjects was 27.7 ± 18.9 nmol/L [median (IQR): 23.5 nmol/L (13.3, 37.3 nmol/L)] and showed significant monthly variation ( P < 0.0001) with the highest values in July and August. Individuals in the middle quintile of neonatal 25(OH)D 3 had lower odds of sustaining a fracture than did those in the lowest quintile (adjusted OR: 0.75; 95% CI: 0.58, 0.96), but a global test did not show any significant overall association (adjusted P = 0.13). Conclusions: This study suggested that neonatal vitamin D status does not influence subsequent fracture risk in childhood. This is in accordance with studies that report no association between antenatal maternal vitamin D status and childhood fractures. Further studies are needed to examine fracture risk in relation to prenatal vitamin D status in a randomized controlled setting. © 2017 American Society for Nutrition.
Prevalence of vitamin A deficiency in pregnant and lactating women in the Republic of Congo.
Samba, Claude; Tchibindat, Félicité; Gourmel, Bernard; Houzé, Patrick; Malvy, Denis
2013-03-01
Vitamin A status in a sample of pregnant and lactating women living in several representative regions of Congo was assessed and compared between August and September 2004. This survey was conducted using a randomized two-stage cluster-sampling method with stratification on 90 clusters, each consisting of at least 15 women. Vitamin A status was determined in a total of 1,054 individuals, using the impression cytology with transfer (ICT) test, the modified relative dose response test (MRDR test) on dried blood spots (DBS), and clinical examination to detect signs of xerophthalmia. The clinical criterion defining vitamin A deficiency was the presence of active xerophthalmia (Bitot's spots [X1B]), active corneal disease), and/or night blindness (XN stage). The prevalence of clinical signs of stage XN and X1B xerophthalmia in the Republic of Congo was found to be 16% and 19% respectively. The prevalence of clinical signs (X1B) was greater in the rural north than in urban areas, with a gradient running from urban (5%) to rural area (33%); 27% of all the ICT tests showed that the subjects were suffering from vitamin A deficiency. The deficiency rates were significantly higher (p < 0.001) in urban surroundings (Brazzaville) than in the rural northern regions. The biochemical MRDR test showed the presence of vitamin A deficiency (> or = 0.06) in 26% of the mothers in Brazzaville compared to 6% in the town of Kouilou; 44% of the women had retinol levels of < 10 microg/dL in the rural north whereas these percentages were significantly lower in the urban areas surveyed (chi-square = 62.30, p < 0.001). A significant correlation was found to exist (p < 0.001) between the ICT test and the MRDR test on DBS. In the population as a whole, 30% of the mothers suffering from malarial attack had abnormally low MRDR levels (> or = 0.06) compared to no malaria. The results of the present study confirm that vitamin A deficiency is a serious public-health issue in pregnant and lactating mothers in the Republic of Congo.
Prevalence of Vitamin A Deficiency in Pregnant and Lactating Women in the Republic of Congo
Tchibindat, Félicité; Gourmel, Bernard; Houzé, Patrick; Malvy, Denis
2013-01-01
Vitamin A status in a sample of pregnant and lactating women living in several representative regions of Congo was assessed and compared between August and September 2004. This survey was conducted using a randomized two-stage cluster-sampling method with stratification on 90 clusters, each consisting of at least 15 women. Vitamin A status was determined in a total of 1,054 individuals, using the impression cytology with transfer (ICT) test, the modified relative dose response test (MRDR test) on dried blood spots (DBS), and clinical examination to detect signs of xerophthalmia. The clinical criterion defining vitamin A deficiency was the presence of active xerophthalmia (Bitot's spots [X1B]), active corneal disease), and/or night blindness (XN stage). The prevalence of clinical signs of stage XN and X1B xerophthalmia in the Republic of Congo was found to be 16% and 19% respectively. The prevalence of clinical signs (X1B) was greater in the rural north than in urban areas, with a gradient running from urban (5%) to rural area (33%); 27% of all the ICT tests showed that the subjects were suffering from vitamin A deficiency. The deficiency rates were significantly higher (p<0.001) in urban surroundings (Brazzaville) than in the rural northern regions. The biochemical MRDR test showed the presence of vitamin A deficiency (≥0.06) in 26% of the mothers in Brazzaville compared to 6% in the town of Kouilou; 44% of the women had retinol levels of <10 μg/dL in the rural north whereas these percentages were significantly lower in the urban areas surveyed (chi-square=62.30, p<0.001). A significant correlation was found to exist (p<0.001) between the ICT test and the MRDR test on DBS. In the population as a whole, 30% of the mothers suffering from malarial attack had abnormally low MRDR levels (≥0.06) compared to no malaria. The results of the present study confirm that vitamin A deficiency is a serious public-health issue in pregnant and lactating mothers in the Republic of Congo. PMID:23617202
Chen, Ying-Chuan; Zhu, Guan-Yu; Wang, Xiu; Shi, Lin; Du, Ting-Ting; Liu, De-Feng; Liu, Yu-Ye; Jiang, Yin; Zhang, Xin; Zhang, Jian-Guo
2017-12-01
Objective The therapeutic efficacy of anterior thalamic nuclei deep brain stimulation (ATN-DBS) against seizures has been largely accepted; however, the effects of ATN-DBS on disruption of the blood-brain barrier (BBB), albumin extravasation, inflammation and apoptosis still remain unclear. Methods Rats were distributed into four treatment groups: physiological saline (PS, N = 12), kainic acid (KA, N = 12), KA-sham-DBS (N = 12) and KA-DBS (N = 12). Seizures were monitored using video-electroencephalogram (EEG). One day after surgery, all rats were sacrificed. Then, samples were prepared for quantitative real-time PCR (qPCR), western blot, immunofluorescence (IF) staining, and transmission electron microscopy to evaluate the disruption of the BBB, albumin extravasation, inflammation, and apoptosis. Result Because of the KA injection, the disruption of the BBB, albumin extravasation, inflammation and apoptosis were more severe in the KA and the KA-sham-DBS groups compared to the PS group (all Ps < 0.05 or < 0.01). The ideal outcomes were observed in the KA-DBS group. ATN-DBS produced a 46.3% reduction in seizure frequency and alleviated the disruption of the BBB, albumin extravasation, inflammatory reaction and apoptosis in comparison to the KA-sham-DBS group (all Ps < 0.05 or < 0.01). Conclusion (1) Seizures can be reduced using ATN-DBS in the epileptogenic stage. (2) ATN-DBS can reduce the disruption of the BBB and albumin extravasation. (3) ATN-DBS has an anti-inflammatory effect in epileptic models.
Outbreak of hepatitis A in an extended family after importation by non-immune travellers.
Kumbang, J; Ejide, S; Tedder, R S; Ngui, S L
2012-10-01
The incidence of hepatitis A in England has declined in recent years, but travel-related cases and imported infections remain a challenge. We report an outbreak of hepatitis A in an extended family where two primary cases were infected while in Pakistan and two secondary cases were infected in England. All four were infected by the same genotype IIIA virus. Testing of the children in the extended family by dried blood spots (DBS) determined that three had evidence of recent past infections (anti-HAV IgM positive), one had a current asymptomatic infection (anti-HAV IgM and HAV RNA positive) and one was incubating the virus (anti-HAV IgM negative, HAV RNA positive). HAV RNA from the DBS was identical to the adult cases. This outbreak demonstrates secondary spread of hepatitis A by asymptomatic children after importation from abroad and highlights the importance of preventing travel-associated hepatitis A infection.
Caggiano, Serena; Ullmann, Nicola; De Vitis, Elisa; Trivelli, Marzia; Mariani, Chiara; Podagrosi, Maria; Ursitti, Fabiana; Bertolaso, Chiara; Putotto, Carolina; Unolt, Marta; Pietravalle, Andrea; Pansa, Paola; Mphayokulela, Kajoro; Lemmo, Maria Incoronata; Mkwambe, Michael; Kazaura, Joseph; Duse, Marzia; Nieddu, Francesco; Azzari, Chiara; Cutrera, Renato
2017-01-01
Community-acquired pneumonia (CAP) is still the most important cause of death in countries with scarce resources. All children (33 months ± 35 DS) discharged from the Pediatric Unit of Itigi Hospital, Tanzania, with a diagnosis of CAP from August 2014 to April 2015 were enrolled. Clinical data were gathered. Dried blood spot (DBS) samples for quantitative real-time polymerase chain reaction (PCR) for bacterial detection were collected in all 100 children included. Twenty-four percent of patients were identified with severe CAP and 11% died. Surprisingly, 54% of patients were admitted with a wrong diagnosis, which increased complications, the need for antibiotics and chest X-rays, and the length of hospitalization. Comorbidity, found in 32% of children, significantly increased severity, complications, deaths, need for chest X-rays, and oxygen therapy. Malnourished children (29%) required more antibiotics. Microbiologically, Streptococcus pneumonia (S. p.), Haemophilus influenza type b (Hib) and Staphylococcus aureus (S. a.) were the bacteria more frequently isolated. Seventy-five percent of patients had mono-infection. Etiology was not correlated with severity, complications, deaths, oxygen demand, or duration of hospitalization. Our study highlights that difficult diagnoses and comorbidities negatively affect clinical evolution. S. p. and Hib still play a large role; thus, implementation of current vaccine strategies is needed. DBS is a simple and efficient diagnostic method for bacterial identification in countries with scarce resources. PMID:28335406
de Mulder, M; York, V A; Wiznia, A A; Michaud, H A; Nixon, D F; Holguin, A; Rosenberg, M G
2014-03-01
With the advent of combined antiretroviral therapy (cART), perinatally HIV-infected children are surviving into adolescence and beyond. However, drug resistance mutations (DRMs) compromise viral control, affecting the long-term effectiveness of ART. The aims of this study were to detect and identify DRMs in a HIV-1 infected paediatric cohort. Paired plasma and dried blood spots (DBSs) specimens were obtained from HIV-1 perinatally infected patients attending the Jacobi Medical Center, New York, USA. Clinical, virological and immunological data for these patients were analysed. HIV-1 pol sequences were generated from samples to identify DRMs according to the International AIDS Society (IAS) 2011 list. Forty-seven perinatally infected patients were selected, with a median age of 17.7 years, of whom 97.4% were carrying subtype B. They had a mean viral load of 3143 HIV-1 RNA copies/mL and a mean CD4 count of 486 cells/μL at the time of sampling. Nineteen patients (40.4%) had achieved undetectable viraemia (< 50 copies/mL) and 40.5% had a CD4 count of > 500 cells/μL. Most of the patients (97.9%) had received cART, including protease inhibitor (PI)-based regimens in 59.6% of cases. The DRM prevalence was 54.1, 27.6 and 27.0% for nucleoside reverse transcriptase inhibitors (NRTIs), PIs and nonnucleoside reverse transcriptase inhibitors (NNRTIs), respectively. Almost two-thirds (64.9%) of the patients harboured DRMs to at least one drug class and 5.4% were triple resistant. The mean nucleotide similarity between plasma and DBS sequences was 97.9%. Identical DRM profiles were present in 60% of plasma-DBS paired sequences. A total of 30 DRMs were detected in plasma and 26 in DBSs, with 23 present in both. Although more perinatally HIV-1-infected children are reaching adulthood as a result of advances in cART, our study cohort presented a high prevalence of resistant viruses, especially viruses resistant to NRTIs. DBS specimens can be used for DRM detection. © 2013 British HIV Association.
Mock, Stephen; Osborn, David J.; Brown, Elizabeth T.; Reynolds, W. Stuart; Turchan, Maxim; Pallavaram, Srivatsan; Rodriguez, William; Dmochowski, Roger; Tolleson, Christopher M.
2016-01-01
Objective Deep Brain Stimulation (DBS) is an established adjunctive surgical intervention for treating Parkinson’s disease (PD) motor symptoms. Both surgical targets, the globus pallidus interna (GPi) and subthalamic nucleus (STN), appear equally beneficial when treating motor symptoms but effects on nonmotor symptoms are not clear. Lower urinary tract symptoms (LUTS) are a common PD complaint. Given prior data in STN-DBS, we aimed to further explore potential benefits in LUTS in both targets. Methods We performed a prospective, non-blinded clinical trial evaluating LUTS in PD patients in both targets pre and post DBS using validated urologic surveys. Participants were already slated for DBS and target selection predetermined before study entry. LUTS was evaluated using: the American Urological Association (AUA-SI), Quality of Life score (QOL), Overactive bladder 8 questionnaire (OAB-q), and sexual health inventory for men (SHIM). Results Of 33 participants, 20 underwent STN DBS and 13 had GPi DBS. Patients demonstrated moderate baseline LUTS. The urologic QOL score significantly improved post DBS (3.24±1.77vs 2.52±1.30; p=0.03). Analyzed by target, only the STN showed significant change in QOL (vs. 2.25±1.33; p=0.04). There were no other significant differences in urologic scores post DBS noted in either target. Conclusion In PD patients with moderate LUTS, there were notable improvements in QOL for LUTS post DBS in the total sample and STN target. There may be differences in DBS effects on LUTS between targets but this will require further larger, blinded studies. PMID:27172446
Poppe, Lisa K; Chunda-Liyoka, Catherine; Kwon, Eun H; Gondwe, Clement; West, John T; Kankasa, Chipepo; Ndongmo, Clement B; Wood, Charles
2017-08-24
The objectives of this study were to determine HIV drug resistance (HIVDR) prevalence in Zambian infants upon diagnosis, and to determine how changing prevention of mother-to-child transmission (PMTCT) drug regimens affect drug resistance. Dried blood spot (DBS) samples from infants in the Lusaka District of Zambia, obtained during routine diagnostic screening, were collected during four different years representing three different PMTCT drug treatment regimens. DNA extracted from dried blood spot samples was used to sequence a 1493 bp region of the reverse transcriptase gene. Sequences were analyzed via the Stanford HIVDRdatabase (http://hivdb.standford.edu) to screen for resistance mutations. HIVDR in infants increased from 21.5 in 2007/2009 to 40.2% in 2014. Nonnucleoside reverse transcriptase inhibitor resistance increased steadily over the sampling period, whereas nucleoside reverse transcriptase inhibitor resistance and dual class resistance both increased more than threefold in 2014. Analysis of drug resistance scores in each group revealed increasing strength of resistance over time. In 2014, children with reported PMTCT exposure, defined as infant prophylaxis and/or maternal treatment, showed a higher prevalence and strength of resistance compared to those with no reported exposure. HIVDR is on the rise in Zambia and presents a serious problem for the successful lifelong treatment of HIV-infected children. PMTCT affects both the prevalence and strength of resistance and further research is needed to determine how to mitigate its role leading to resistance.
Oriero, Eniyou C; Okebe, Joseph; Jacobs, Jan; Van Geertruyden, Jean-Pierre; Nwakanma, Davis; D'Alessandro, Umberto
2015-10-09
New diagnostic tools to detect reliably and rapidly asymptomatic and low-density malaria infections are needed as their treatment could interrupt transmission. Isothermal amplification techniques are being explored for field diagnosis of malaria. In this study, a novel molecular tool (loop-mediated isothermal amplification-LAMP) targeting the apicoplast genome of Plasmodium falciparum was evaluated for the detection of asymptomatic malaria-infected individuals in a rural setting in The Gambia. A blood was collected from 341 subjects (median age 9 years, range 1-68 years) screened for malaria. On site, a rapid diagnostic test (RDT, SD Bioline Malaria Antigen P.f) was performed, thick blood films (TBF) slides for microscopy were prepared and dry blood spots (DBS) were collected on Whatman(®) 903 Specimen collection paper. The TBF and DBS were transported to the field laboratory where microscopy and LAMP testing were performed. The latter was done on DNA extracted from the DBS using a crude (methanol/heating) extraction method. A laboratory-based PCR amplification was done on all the samples using DNA extracted with the Qiagen kit and its results were taken as reference for all the other tests. Plasmodium falciparum malaria prevalence was 37 % (127/341) as detected by LAMP, 30 % (104/341) by microscopy and 37 % (126/341) by RDT. Compared to the reference PCR method, sensitivity was 92 % for LAMP, 78 % for microscopy, and 76 % for RDT; specificity was 97 % for LAMP, 99 % for microscopy, and 88 % for RDT. Area under the receiver operating characteristic (ROC) curve in comparison with the reference standard was 0.94 for LAMP, 0.88 for microscopy and 0.81 for RDT. Turn-around time for the entire LAMP assay was approximately 3 h and 30 min for an average of 27 ± 9.5 samples collected per day, compared to a minimum of 10 samples an hour per operator by RDT and over 8 h by microscopy. The LAMP assay could produce reliable results the same day of the screening. It could detect a higher proportion of low density malaria infections than the other methods tested and may be used for large campaigns of systematic screening and treatment.
Diouara, Abou Abdallah Malick; Ndiaye, Halimatou Diop; Guindo, Ibrehima; Bangoura, Nestor; Cissé, Mohamed; Edmond, Tchiakpe; Bougoudogo, Flabou; Mboup, Souleymame; Peeters, Martine; Ayouba, Ahidjo; Kane, Ndèye Coumba Touré
2014-01-01
Access to antiretroviral treatment (ART) becomes more and more effective in resource-limited settings (RLS). However, this global effort would be even more profitable if the access to laboratory services especially in decentralized settings was strengthened. We report the virological outcome and HIV-1 drug resistance in three West African countries using dried blood spots (DBS) samples. We included HIV-1-infected adults on ART ≥6 months and followed up in capital cities and decentralized sites in Senegal, Mali and Guinea-Conakry. Patients were consecutively enrolled and DBS were collected in field conditions and kept at ambient temperature before transfer to the reference laboratory. Viral load (VL) was quantified using the NucliSENS EasyQ HIV-1 v1.2. Genotyping of HIV-1 pol gene was performed using in-house protocol. Of the 407 participants, 119, 152 and 136 were from Senegal, Mali and Guinea-Conakry, respectively. The median treatment duration was 36 months [IQR: 6-136]. Virological failure (VF) (VL≥3log10 copies/mL) was observed in 26% (95% confidence interval (CI), 18-35; n=31), 11% (95% CI, 6-17; n=16) and 24% (95% CI, 17-32; n=33) of patients in Senegal, Mali and Guinea-Conakry, respectively (p=0.001). Of samples presenting VL≥3log10 copies/mL (n=80), 70 were successfully genotyped. At least one drug resistance mutation (DRM) was detected in the following proportions: 70% (95% CI, 50-86; n=19), 93% (95% CI, 68-100; n=14) and 68% (95% CI, 48-84; n=19) in Senegal, Mali and Guinea-Conakry, respectively (p=0.22). Twenty-six per cent (26%; 95% CI, 16-38; n=18) of patients in VF harboured wild-type viruses, which is likely indicative of weak adherence. Phylogenetic analysis showed the predominance of CRF02_AG subtype (73%; 95% CI, 61-83; n=51). We describe the ART outcome in capital and rural settings of Senegal, Mali and Guinea-Conakry. Our results in all of the three countries highlight the need to reinforce the ART adherence in order to minimize the occurrence of drug resistance. In addition, these findings provide additional evidence that the use of DBS as a sampling support could assist virological monitoring of patients on ART in remote areas.
Effects of thalamic deep brain stimulation on spontaneous language production.
Ehlen, Felicitas; Vonberg, Isabelle; Kühn, Andrea A; Klostermann, Fabian
2016-08-01
The thalamus is thought to contribute to language-related processing, but specifications of this notion remain vague. An assessment of potential effects of thalamic deep brain stimulation (DBS) on spontaneous language may help to delineate respective functions. For this purpose, we analyzed spontaneous language samples from thirteen (six female / seven male) patients with essential tremor treated with DBS of the thalamic ventral intermediate nucleus (VIM) in their respective ON vs. OFF conditions. Samples were obtained from semi-structured interviews and examined on multidimensional linguistic levels. In the VIM-DBS ON condition, participants used a significantly higher proportion of paratactic as opposed to hypotactic sentence structures. This increase correlated negatively with the change in the more global cognitive score, which in itself did not change significantly. In conclusion, VIM-DBS appears to induce the use of a simplified syntactic structure. The findings are discussed in relation to concepts of thalamic roles in language-related cognitive behavior. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis
2016-01-01
Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0–100.0) and 100.0% (95% CI: 96.0–100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0–100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9 copies/mL at 95% CIs (p = 0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. PMID:24726703
Chang, Joy; Omuomo, Kenneth; Anyango, Emily; Kingwara, Leonard; Basiye, Frank; Morwabe, Alex; Shanmugam, Vedapuri; Nguyen, Shon; Sabatier, Jennifer; Zeh, Clement; Ellenberger, Dennis
2014-08-01
Timely diagnosis and treatment of infants infected with HIV are critical for reducing infant mortality. High-throughput automated diagnostic tests like Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 Qual Test (Roche CAPCTM Qual) and the Abbott Real Time HIV-1 Qualitative (Abbott Qualitative) can be used to rapidly expand early infant diagnosis testing services. In this study, the performance characteristics of the Abbott Qualitative were evaluated using two hundred dried blood spots (DBS) samples (100 HIV-1 positive and 100 HIV-1 negative) collected from infants attending the antenatal facilities in Kisumu, Kenya. The Abbott Qualitative results were compared to the diagnostic testing completed using the Roche CAPCTM Qual in Kenya. The sensitivity and specificity of the Abbott Qualitative were 99.0% (95% CI: 95.0-100.0) and 100.0% (95% CI: 96.0-100.0), respectively, and the overall reproducibility was 98.0% (95% CI: 86.0-100.0). The limits of detection for the Abbott Qualitative and Roche CAPCTM Qual were 56.5 and 6.9copies/mL at 95% CIs (p=0.005), respectively. The study findings demonstrate that the Abbott Qualitative test is a practical option for timely diagnosis of HIV in infants. Published by Elsevier B.V.
Balinda, Sheila N; Ondoa, Pascale; Obuku, Ekwaro A; Kliphuis, Aletta; Egau, Isaac; Bronze, Michelle; Kasambula, Lordwin; Schuurman, Rob; Spieker, Nicole; Rinke de Wit, Tobias F; Kityo, Cissy
2016-01-01
WHO recommends regular viral load (VL) monitoring of patients on antiretroviral therapy (ART) for timely detection of virological failure, prevention of acquired HIV drug resistance (HIVDR) and avoiding unnecessary switching to second-line ART. However, the cost and complexity of routine VL testing remains prohibitive in most resource limited settings (RLS). We evaluated a simple, low-cost, qualitative viral-failure assay (VFA) on dried blood spots (DBS) in three clinical settings in Uganda. We conducted a cross-sectional diagnostic accuracy study in three HIV/AIDS treatment centres at the Joint Clinical Research Centre in Uganda. The VFA employs semi-quantitative detection of HIV-1 RNA amplified from the LTR gene. We used paired dry blood spot (DBS) and plasma with the COBASAmpliPrep/COBASTaqMan, Roche version 2 (VLref) as the reference assay. We used the VFA at two thresholds of viral load, (>5,000 or >1,000 copies/ml). 496 paired VFA and VLref results were available for comparative analysis. Overall, VFA demonstrated 78.4% sensitivity, (95% CI: 69.7%-87.1%), 93% specificity (95% CI: 89.7%-96.4%), 89.3% accuracy (95% CI: 85%-92%) and an agreement kappa = 0.72 as compared to the VLref. The predictive values of positivity and negativity among patients on ART for >12 months were 72.7% and 99.3%, respectively. VFA allowed 89% of correct classification of VF. Only 11% of the patients were misclassified with the potential of unnecessary or late switch to second-line ART. Our findings present an opportunity to roll out simple and affordable VL monitoring for HIV-1 treatment in RLS.
Johnson, Sheri L.; Leedom, Liane J.; Muhtadie, Luma
2012-01-01
The dominance behavioral system (DBS) can be conceptualized as a biologically-based system which guides dominance motivation, dominant and subordinate behavior, and responsivity to perceptions of power and subordination. A growing body of research suggests that problems with the DBS are evident across a broad range of psychopathologies. We begin by describing psychological, social, and biological correlates of the dominance behavioral system (DBS). Extensive research suggests that externalizing disorders, mania-proneness, and narcissistic traits are related to heightened dominance motivation and behaviors. Mania and narcissistic traits also appear related to inflated self-perceptions of power. Anxiety and depression are related to subordination and submissiveness, as well as a desire to avoid subordination. Models of the DBS have received support from research with humans and animals; from self-report, observational, and biological methods; and using naturalistic and experimental paradigms. Limitations of available research include the relative lack of longitudinal studies using multiple measures of the DBS and the absence of relevant studies using diagnosed samples to study narcissistic personality disorder and bipolar disorder. We provide suggestions for future research on the DBS and psychopathology, including investigations of whether the DBS can be used to differentiate specific disorder outcomes; the need for more sophisticated biological research; and the value of longitudinal dynamical research. Implications of using the DBS as a tool in clinical assessment and treatment are discussed. PMID:22506751
Sports drug testing using complementary matrices: Advantages and limitations.
Thevis, Mario; Geyer, Hans; Tretzel, Laura; Schänzer, Wilhelm
2016-10-25
Today, routine doping controls largely rely on testing whole blood, serum, and urine samples. These matrices allow comprehensively covering inorganic as well as low and high molecular mass organic analytes relevant to doping controls and are collecting and transferring from sampling sites to accredited anti-doping laboratories under standardized conditions. Various aspects including time and cost-effectiveness as well as intrusiveness and invasiveness of the sampling procedure but also analyte stability and breadth of the contained information have been motivation to consider and assess values potentially provided and added to modern sports drug testing programs by alternative matrices. Such alternatives could be dried blood spots (DBS), dried plasma spots (DPS), oral fluid (OF), exhaled breath (EB), and hair. In this review, recent developments and test methods concerning these alternative matrices and expected or proven contributions as well as limitations of these specimens in the context of the international anti-doping fight are presented and discussed, guided by current regulations for prohibited substances and methods of doping as established by the World Anti-Doping Agency (WADA). Focusing on literature published between 2011 and 2015, examples for doping control analytical assays concerning non-approved substances, anabolic agents, peptide hormones/growth factors/related substances and mimetics, β 2 -agonists, hormone and metabolic modulators, diuretics and masking agents, stimulants, narcotics, cannabinoids, glucocorticoids, and beta-blockers were selected to outline the advantages and limitations of the aforementioned alternative matrices as compared to conventional doping control samples (i.e. urine and blood/serum). Copyright © 2016 Elsevier B.V. All rights reserved.
Mathkour, Mansour; Garces, Juanita; Scullen, Tyler; Hanna, Joshua; Valle-Giler, Edison; Kahn, Lora; Arrington, Teresa; Houghton, David; Lea, Georgia; Biro, Erin; Bui, Cuong J; Sulaiman, Olawale A R; Smith, Roger D
2017-01-01
Parkinson disease (PD) is a common neurodegenerative disease in elderly patients that may be treated with deep brain stimulation (DBS). DBS is an accepted surgical treatment in PD patients <70 years that demonstrates marked improvement in disease symptomology. Patients ≥70 years historically have been excluded from DBS therapy. Our objective is to evaluate the short- and long-term outcomes in patients with PD ≥70 years who underwent DBS at our center. In our single-center study, we retrospectively assessed a prospective registry of patients with PD treated with DBS who were ≥70 years old at the time of their procedure. Univariate analyses and 1-sample paired t test were used to evaluate data. Motor scores were evaluated with the Unified Parkinson's Disease Rating Scale III, and the effects on medication requirements were evaluated with levodopa equivalence daily doses (LEDD). Thirty-seven patients were followed for an average of 42.2 months post-DBS. The average ages at diagnosis and at the time of DBS surgery were 63.05 years and 72.45 years, respectively. Significant reductions in the average Unified Parkinson's Disease Rating Scale III score were observed (preoperative 31.8; postoperative 15.6; P < 0.0001). Significant reductions in the average LEDD (preoperative 891.94 mg; postoperative 559.6 mg; P = 0.0008) and medication doses per day (preoperative 11.54; postoperative 7.97; P = 0.0112) also were present. DBS is effective in treating elderly patients with PD. Patients experienced improvement in motor function, LEDD, and medication doses per day after DBS. Our results suggest that DBS is an effective treatment modality in elderly patients with PD. Copyright © 2016 Elsevier Inc. All rights reserved.
Combs, Hannah L; Folley, Bradley S; Berry, David T R; Segerstrom, Suzanne C; Han, Dong Y; Anderson-Mooney, Amelia J; Walls, Brittany D; van Horne, Craig
2015-12-01
Parkinson's disease (PD) is a common, degenerative disorder of the central nervous system. Individuals experience predominantly extrapyramidal symptoms including resting tremor, rigidity, bradykinesia, gait abnormalities, cognitive impairment, depression, and neurobehavioral concerns. Cognitive impairments associated with PD are diverse, including difficulty with attention, processing speed, executive functioning, memory recall, visuospatial functions, word-retrieval, and naming. Deep brain stimulation (DBS) of the subthalamic nucleus (STN) or globus pallidus internus (GPi) is FDA approved and has been shown to be effective in reducing motor symptoms of PD. Studies have found that stimulating STN and GPi are equally effective at improving motor symptoms and dyskinesias; however, there has been discrepancy as to whether the cognitive, behavioral, and mood symptoms are affected differently between the two targets. The present study used random-effects meta-analytic models along with a novel p-curve analytic procedure to compare the potential cognitive and emotional impairments associated with STN-DBS in the current literature to those associated with GPi-DBS. Forty-one articles were reviewed with an aggregated sample size of 1622 patients. Following STN-DBS, small declines were found in psychomotor speed, memory, attention, executive functions, and overall cognition; and moderate declines were found in both semantic and phonemic fluency. However, GPi-DBS resulted in fewer neurocognitive declines than STN-DBS (small declines in attention and small-moderate declines in verbal fluency). With regards to its effect on depression symptomatology, both GPi-DBS and STN-DBS resulted in lower levels of depressive symptoms post-surgery. From a neurocognitive standpoint, both GPi-DBS and STN-DBS produce subtle cognitive declines but appears to be relatively well tolerated.
Therrell, Bradford L
2003-01-01
At birth, patient demographic and health information begin to accumulate in varied databases. There are often multiple sources of the same or similar data. New public health programs are often created without considering data linkages. Recently, newborn hearing screening (NHS) programs and immunization programs have virtually ignored the existence of newborn dried blood spot (DBS) newborn screening databases containing similar demographic data, creating data duplication in their 'new' systems. Some progressive public health departments are developing data warehouses of basic, recurrent patient information, and linking these databases to other health program databases where programs and services can benefit from such linkages. Demographic data warehousing saves time (and money) by eliminating duplicative data entry and reducing the chances of data errors. While newborn screening data are usually the first data available, they should not be the only data source considered for early data linkage or for populating a data warehouse. Birth certificate information should also be considered along with other data sources for infants that may not have received newborn screening or who may have been born outside of the jurisdiction and not have birth certificate information locally available. This newborn screening serial number provides a convenient identification number for use in the DBS program and for linking with other systems. As a minimum, data linkages should exist between newborn dried blood spot screening, newborn hearing screening, immunizations, birth certificates and birth defect registries.
Coolidge, Trilby; Hillstead, M Blake; Farjo, Nadia; Weinstein, Philip; Coldwell, Susan E
2010-05-13
Hispanics comprise the largest ethnic minority group in the United States. Previous work with the Spanish Modified Dental Anxiety Scale (MDAS) yielded good validity, but lower test-retest reliability. We report the performance of the Spanish MDAS in a new sample, as well as the performance of the Spanish Revised Dental Beliefs Survey (R-DBS). One hundred sixty two Spanish-speaking adults attending Spanish-language church services or an Hispanic cultural festival completed questionnaires containing the Spanish MDAS, Spanish R-DBS, and dental attendance questions, and underwent a brief oral examination. Church attendees completed the questionnaire a second time, for test-retest purposes. The Spanish MDAS and R-DBS were completed by 156 and 136 adults, respectively. The test-retest reliability of the Spanish MDAS was 0.83 (95% CI = 0.60-0.92). The internal reliability of the Spanish R-DBS was 0.96 (95% CI = 0.94-0.97), and the test-retest reliability was 0.86 (95% CI = 0.64-0.94). The two measures were significantly correlated (Spearman's rho = 0.38, p < 0.001). Participants who do not currently go to a dentist had significantly higher MDAS scores (t = 3.40, df = 106, p = 0.003) as well as significantly higher R-DBS scores (t = 2.21, df = 131, p = 0.029). Participants whose most recent dental visit was for pain or a problem, rather than for a check-up, scored significantly higher on both the MDAS (t = 3.00, df = 106, p = 0.003) and the R-DBS (t = 2.85, df = 92, p = 0.005). Those with high dental fear (MDAS score 19 or greater) were significantly more likely to have severe caries (Chi square = 6.644, df = 2, p = 0.036). Higher scores on the R-DBS were significantly related to having more missing teeth (Spearman's rho = 0.23, p = 0.009). In this sample, the test-retest reliability of the Spanish MDAS was higher. The significant relationships between dental attendance and questionnaire scores, as well as the difference in caries severity seen in those with high fear, add to the evidence of this scale's construct validity in Hispanic samples. Our results also provide evidence for the internal and test-retest reliabilities, as well as the construct validity, of the Spanish R-DBS.
Kubaski, Francyne; Mason, Robert W.; Nakatomi, Akiko; Shintaku, Haruo; Xie, Li; van Vlies, Naomi N.; Church, Heather; Giugliani, Roberto; Kobayashi, Hironori; Yamaguchi, Seiji; Suzuki, Yasuyuki; Orii, Tadao; Fukao, Toshiyuki; Montaño, Adriana M.; Tomatsu, Shunji
2016-01-01
BACKGROUND Mucopolysaccharidoses (MPS) are a group of inborn errors of metabolism that are progressive and usually result in irreversible in skeletal, visceral and/or brain damage, highlighting a need for early diagnosis. METHODS This pilot study analyzed 2,862 dried blood spots (DBS) from newborns and 14 DBS from newborn patients with MPS (MPS I, n = 7; MPS II, n = 2; MPS III, n = 5). Disaccharides were produced from polymer GAGs by digestion with chondroitinase B, heparitinase, and keratanase II. Heparan sulfate (0S, NS), dermatan sulfate (DS) and mono- and di-sulfated KS were measured by liquid chromatography tandem mass spectrometry (LC-MS/MS). Median absolute deviation (MAD) was used to determine cutoffs to distinguish patients from controls. Cutoffs were defined as median + 7× MAD from general newborns. RESULTS The cutoffs were as follows: HS-0S> 90ng/mL; HS-NS> 23 ng/mL, DS> 88 ng/mL; mono-sulfated KS> 445 ng/mL; di-sulfated KS> 89 ng/mL and ratio di-KS in total KS> 32%. All MPS I and II samples were above the cutoffs for HS-0S, HS-NS and DS, and all MPS III samples were above cutoffs for HS-0S and HS-NS. The rate of false positives for MPS I and II was 0.03% based on a combination of HS-0S, HS-NS, and DS, and for MPS III was 0.9% based upon a combination of HS-0S and HS-NS. CONCLUSIONS Combination of levels of two or more different GAGs improves separation of MPS patients from unaffected controls, indicating that GAG measurements are potentially valuable biomarkers for newborn screening for MPS. PMID:27718145
Kubaski, Francyne; Mason, Robert W; Nakatomi, Akiko; Shintaku, Haruo; Xie, Li; van Vlies, Naomi N; Church, Heather; Giugliani, Roberto; Kobayashi, Hironori; Yamaguchi, Seiji; Suzuki, Yasuyuki; Orii, Tadao; Fukao, Toshiyuki; Montaño, Adriana M; Tomatsu, Shunji
2017-01-01
Mucopolysaccharidoses (MPS) are a group of inborn errors of metabolism that are progressive and usually result in irreversible skeletal, visceral, and/or brain damage, highlighting a need for early diagnosis. This pilot study analyzed 2862 dried blood spots (DBS) from newborns and 14 DBS from newborn patients with MPS (MPS I, n = 7; MPS II, n = 2; MPS III, n = 5). Disaccharides were produced from polymer GAGs by digestion with chondroitinase B, heparitinase, and keratanase II. Heparan sulfate (0S, NS), dermatan sulfate (DS) and mono- and di-sulfated KS were measured by liquid chromatography tandem mass spectrometry (LC-MS/MS). Median absolute deviation (MAD) was used to determine cutoffs to distinguish patients from controls. Cutoffs were defined as median + 7× MAD from general newborns. The cutoffs were as follows: HS-0S > 90 ng/mL; HS-NS > 23 ng/mL, DS > 88 ng/mL; mono-sulfated KS > 445 ng/mL; di-sulfated KS > 89 ng/mL and ratio di-KS in total KS > 32 %. All MPS I and II samples were above the cutoffs for HS-0S, HS-NS, and DS, and all MPS III samples were above cutoffs for HS-0S and HS-NS. The rate of false positives for MPS I and II was 0.03 % based on a combination of HS-0S, HS-NS, and DS, and for MPS III was 0.9 % based upon a combination of HS-0S and HS-NS. Combination of levels of two or more different GAGs improves separation of MPS patients from unaffected controls, indicating that GAG measurements are potentially valuable biomarkers for newborn screening for MPS.
Obeso, Ignacio; Wilkinson, Leonora; Rodríguez-Oroz, Maria-Cruz; Obeso, Jose A; Jahanshahi, Marjan
2013-05-01
It has been proposed that the subthalamic nucleus (STN) mediates response inhibition and conflict resolution through the fronto-basal ganglia pathways. Our aim was to compare the effects of deep brain stimulation (DBS) of the STN on reactive and proactive inhibition and conflict resolution in Parkinson's disease using a single task. We used the conditional Stop signal reaction time task that provides the Stop signal reaction time (SSRT) as a measure of reactive inhibition, the response delay effect (RDE) as a measure of proactive inhibition and conflict-induced slowing (CIS) as a measure of conflict resolution. DBS of the STN significantly prolonged SSRT relative to stimulation off. However, while the RDE measure of proactive inhibition was not significantly altered by DBS of the STN, relative to healthy controls, RDE was significantly lower with DBS off but not DBS on. DBS of the STN did not alter the mean CIS but produced a significant differential effect on the slowest and fastest RTs on conflict trials, further prolonging the slowest RTs on the conflict trials relative to DBS off and to controls. These results are the first demonstration, using a single task in the same patient sample, that DBS of the STN produces differential effects on reactive and proactive inhibition and on conflict resolution, suggesting that these effects are likely to be mediated through the impact of STN stimulation on different fronto-basal ganglia pathways: hyperdirect, direct and indirect.
Cognitive function in children with primary dystonia before and after deep brain stimulation.
Owen, Tamsin; Gimeno, Hortensia; Selway, Richard; Lin, Jean-Pierre
2015-01-01
Dystonia is characterised by involuntary movements (twisting, writhing and jerking) and postures. The effects of deep brain stimulation (DBS) surgery on the motor aspect of primary dystonias have been well reported, however, there is a paucity of research investigating its impact on cognitive function, particularly in childhood dystonia. We performed a follow-up of cognitive function in children with primary dystonia following DBS pallidal surgery. Cognitive function was measured in a cohort of 13 children with primary or primary plus dystonia who had undergone DBS surgery using a retrospective case series design. Baseline pre-DBS neuropsychological measures were compared to scores obtained at least one year following DBS. Cognitive function was assessed using standardised measures of intellectual ability and memory. All children demonstrated improvements with regard to dystonia reduction, as measured by the Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS). Overall, cognition remained stable following DBS in the majority of the cohort. Individual case analysis revealed improvements in some domains of cognitive function in eight members of the cohort and a deterioration of certain domains in four. Cognition largely remained stable in children with primary/primary plus dystonia following DBS surgery, although further research with a larger sample is necessary to explore this statistically. Notwithstanding the limitations of a small size, this preliminary data has potentially positive implications for the impact of DBS on cognitive functioning within a paediatric population. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
A prototypic small molecule database for bronchoalveolar lavage-based metabolomics
NASA Astrophysics Data System (ADS)
Walmsley, Scott; Cruickshank-Quinn, Charmion; Quinn, Kevin; Zhang, Xing; Petrache, Irina; Bowler, Russell P.; Reisdorph, Richard; Reisdorph, Nichole
2018-04-01
The analysis of bronchoalveolar lavage fluid (BALF) using mass spectrometry-based metabolomics can provide insight into lung diseases, such as asthma. However, the important step of compound identification is hindered by the lack of a small molecule database that is specific for BALF. Here we describe prototypic, small molecule databases derived from human BALF samples (n=117). Human BALF was extracted into lipid and aqueous fractions and analyzed using liquid chromatography mass spectrometry. Following filtering to reduce contaminants and artifacts, the resulting BALF databases (BALF-DBs) contain 11,736 lipid and 658 aqueous compounds. Over 10% of these were found in 100% of samples. Testing the BALF-DBs using nested test sets produced a 99% match rate for lipids and 47% match rate for aqueous molecules. Searching an independent dataset resulted in 45% matching to the lipid BALF-DB compared to<25% when general databases are searched. The BALF-DBs are available for download from MetaboLights. Overall, the BALF-DBs can reduce false positives and improve confidence in compound identification compared to when general databases are used.
Van Gompel, Jamie J.; Chang, Su-Youne; Goerss, Stephan J.; Kim, In Yong; Kimble, Christopher; Bennet, Kevin E.; Lee, Kendall H.
2010-01-01
Deep brain stimulation (DBS) is effective when there appears to be a distortion in the complex neurochemical circuitry of the brain. Currently, the mechanism of DBS is incompletely understood; however, it has been hypothesized that DBS evokes release of neurochemicals. Well-established chemical detection systems such as microdialysis and mass spectrometry are impractical if one is assessing changes that are happening on a second-to-second time scale or for chronically used implanted recordings, as would be required for DBS feedback. Electrochemical detection techniques such as fast-scan cyclic voltammetry (FSCV) and amperometry have until recently remained in the realm of basic science; however, it is enticing to apply these powerful recording technologies to clinical and translational applications. The Wireless Instantaneous Neurochemical Concentration Sensor (WINCS) currently is a research device designed for human use capable of in vivo FSCV and amperometry, sampling at subsecond time resolution. In this paper, the authors review recent advances in this electrochemical application to DBS technologies. The WINCS can detect dopamine, adenosine, and serotonin by FSCV. For example, FSCV is capable of detecting dopamine in the caudate evoked by stimulation of the subthalamic nucleus/substantia nigra in pig and rat models of DBS. It is further capable of detecting dopamine by amperometry and, when used with enzyme linked sensors, both glutamate and adenosine. In conclusion, WINCS is a highly versatile instrument that allows near real-time (millisecond) detection of neurochemicals important to DBS research. In the future, the neurochemical changes detected using WINCS may be important as surrogate markers for proper DBS placement as well as the sensor component for a “smart” DBS system with electrochemical feedback that allows automatic modulation of stimulation parameters. Current work is under way to establish WINCS use in humans. PMID:20672923
NASA Astrophysics Data System (ADS)
Quarles, C. A.; Sheffield, Thomas; Stacy, Scott; Yang, Chun
2009-03-01
The uniformity of rubber-carbon black composite materials has been investigated with positron Doppler Broadening Spectroscopy (DBS). The number of grams of carbon black (CB) mixed into one hundred grams of rubber, phr, is used to characterize a sample. A typical concentration for rubber in tires is 50 phr. The S parameter measured by DBS has been found to depend on the phr of the sample as well as the type of rubber and carbon black. The variation in carbon black concentration within a surface area of about 5 mm diameter can be measured by moving a standard Na-22 or Ge-68 positron source over an extended sample. The precision of the concentration measurement depends on the dwell time at a point on the sample. The time required to determine uniformity over an extended sample can be reduced by running with much higher counting rate than is typical in DBS and correcting for the systematic variation of S parameter with counting rate. Variation in CB concentration with mixing time at the level of about 0.5% has been observed.
Golsari, Amir; Nasimzadah, Arzoo; Thomalla, Götz; Keller, Sarah; Gerloff, Christian; Magnus, Tim
2018-03-01
We examined patients with limb-girdle muscle weakness and/or hyper-CKaemia and undiagnosed muscle biopsy for late onset Pompe disease (LOPD). Patients with an inconclusive limb-girdle muscle weakness who presented at our neuromuscular centre between 2005 and 2015 with undiagnosed muscle biopsies were examined by dry blood spot testing (DBS) including determination of the enzyme activity of acid alpha-glucosidase (GAA). In the case of depressed enzyme activity, additional gene testing of the GAA gene was carried out. Of the 340 evaluated muscle biopsies, 69 patients fulfilled the inclusion criteria and were examined with DBS. Among those patients, 76% showed a limb-girdle muscle weakness and 14% showed a hyper-CKaemia. A diagnosis of LOPD could be established in the case of two patients (2.9%) with reduced GAA enzyme activity and proof of mutations in the GAA gene. One of the two patients presents in the muscle biopsy suggestive features of Pompe disease including vacuoles with positive acid phosphatase reaction. In summary, our results show that a muscle biopsy can be helpful in identifying LOPD patients, but vacuolation with glycogen storage can also be absent. An inconspicuous muscle biopsy does not rule out Pompe disease. Consequently, all patients with limb-girdle muscle weakness should be examined by DBS before conducting a muscle biopsy. Copyright © 2017 Elsevier B.V. All rights reserved.
Karlsson, Fredrik; Malinova, Elin; Olofsson, Katarina; Blomstedt, Patric; Linder, Jan; Nordh, Erik
2018-01-17
We aimed to study the effect of deep brain stimulation (DBS) in the subthalamic nucleus (STN) and caudal zona incerta (cZi) on level of perceived voice tremor in patients with Parkinson disease (PD). This is a prospective nonrandomized design with consecutive patients. Perceived voice tremor was assessed in patients with PD having received either STN-DBS (8 patients, 5 bilateral and 3 unilateral, aged 43.1-73.6 years; median = 61.2 years) or cZi-DBS (14 bilateral patients, aged 39.0-71.9 years; median = 56.6 years) 12 months before the assessment. Sustained vowels that were produced OFF and ON stimulation (with simultaneous l-DOPA medication) were assessed perceptually in terms of voice tremor by two raters on a four-point rating scale. The assessments were repeated five times per sample and rated in a blinded and randomized procedure. Three out of the 22 patients (13%) were concluded to have voice tremor OFF stimulation. Patients with PD with STN-DBS showed mild levels of perceived voice tremor OFF stimulation and a group level improvement. Patients with moderate/severe perceived voice tremor and cZi-DBS showed marked improvements, but there was no overall group effect. Six patients with cZi-DBS showed small increases in perceived voice tremor severity. STN-DBS decreased perceived voice tremor on a group level. cZi-DBS decreased perceived voice tremor in patients with PD with moderate to severe preoperative levels of the symptom. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
2010-01-01
Background Hispanics comprise the largest ethnic minority group in the United States. Previous work with the Spanish Modified Dental Anxiety Scale (MDAS) yielded good validity, but lower test-retest reliability. We report the performance of the Spanish MDAS in a new sample, as well as the performance of the Spanish Revised Dental Beliefs Survey (R-DBS). Methods One hundred sixty two Spanish-speaking adults attending Spanish-language church services or an Hispanic cultural festival completed questionnaires containing the Spanish MDAS, Spanish R-DBS, and dental attendance questions, and underwent a brief oral examination. Church attendees completed the questionnaire a second time, for test-retest purposes. Results The Spanish MDAS and R-DBS were completed by 156 and 136 adults, respectively. The test-retest reliability of the Spanish MDAS was 0.83 (95% CI = 0.60-0.92). The internal reliability of the Spanish R-DBS was 0.96 (95% CI = 0.94-0.97), and the test-retest reliability was 0.86 (95% CI = 0.64-0.94). The two measures were significantly correlated (Spearman's rho = 0.38, p < 0.001). Participants who do not currently go to a dentist had significantly higher MDAS scores (t = 3.40, df = 106, p = 0.003) as well as significantly higher R-DBS scores (t = 2.21, df = 131, p = 0.029). Participants whose most recent dental visit was for pain or a problem, rather than for a check-up, scored significantly higher on both the MDAS (t = 3.00, df = 106, p = 0.003) and the R-DBS (t = 2.85, df = 92, p = 0.005). Those with high dental fear (MDAS score 19 or greater) were significantly more likely to have severe caries (Chi square = 6.644, df = 2, p = 0.036). Higher scores on the R-DBS were significantly related to having more missing teeth (Spearman's rho = 0.23, p = 0.009). Conclusion In this sample, the test-retest reliability of the Spanish MDAS was higher. The significant relationships between dental attendance and questionnaire scores, as well as the difference in caries severity seen in those with high fear, add to the evidence of this scale's construct validity in Hispanic samples. Our results also provide evidence for the internal and test-retest reliabilities, as well as the construct validity, of the Spanish R-DBS. PMID:20465835
Dhillon, Kuldeep S; Bhandal, Ajit S; Aznar, Constantino P; Lorey, Fred W; Neogi, Partha
2011-05-12
Succinylacetone (SUAC), a specific marker for tyrosinemia type I (Tyr I) cannot be detected by the routine LC-MS/MS screening of amino acids (AA) and acylcarnitines (AC) in newborns. The current derivatized methods require double extraction of newborn dried blood spots (DBS); one for AA and AC and the second for SUAC from the blood spot left after the first extraction. We have developed a method in which AA, AC and SUAC are extracted in a single extraction resulting in significant reduction in labor and assay time. The 3.2 mm DBS were extracted by incubating at 45 °C for 45 min with 100 μl of acetonitrile (ACN)-water-formic acid mixture containing hydrazine and stable-isotope labeled internal standards of AA, AC and SUAC. The extract was derivatized with n-butanolic-HCl and analyzed by LC-MS/MS. The average inter-assay CVs for, AA, AC and SUAC were 10.1, 10.8 and 7.1% respectively. The extraction of analytes with ACN-water mixture showed no significant difference in their recovery compared to commonly used solvent MeOH. The concentration of hydrazine had considerable impact on SUAC extraction. We developed a new MS/MS derivatized method to detect AA/AC/SUAC in a single extraction process for screening Tyr I along with disorders of AA and AC. Published by Elsevier B.V.
Jukić, Tomislav; Zimmermann, Michael Bruce; Granić, Roko; Prpić, Marin; Krilić, Drazena; Juresa, Vesna; Katalenić, Marijan; Kusić, Zvonko
2015-12-01
Current methods for assessment of iodine intake in a population comprise measurements of urinary iodine concentration (UIC), thyroid volume by ultrasound (US-Tvol), and newborn TSH. Serum or dried blood spot thyroglobulin (DBS-Tg) is a new promising functional iodine status biomarker in children. In 1996, a new act on universal salt iodination was introduced in Croatia with 25 mg of potassium iodideper kg of salt. In 2002, Croatia finally reached iodine sufficiency. However, in 2009, median UIC in 101 schoolchildren from Zagreb, the capital of Croatia, was 288 µg/L, posing to be excessive. The aim of the study was to assess iodine intake in schoolchildren from the Zagreb area and to evaluate the value of DBS-Tg in schoolchildren as a new functional biomarker of iodine deficiency (and iodine excess). The study was part of a large international study in 6- to 12-year-old children supported by UNICEF, the Swiss Federal Institute of Technology (ETH Zurich) and the International Council for the Control of Iodine Deficiency Disorders (ICCIDD). According to international study results, the median cut-off Tg < 13 µg/L and/or < 3% Tg values > 40 µg/L indicate iodine sufficiency. The study included 159 schoolchildren (median age 9.1 ± 1.4 years) from Zagreb and a nearby small town of Jastrebarsko with measurements of UIC, US-Tvol, DBS-Tg, T4, TSH and iodine content in salt from households of schoolchildren (KI/kg of salt). Overall median UIC was 205 µg/L (range 1-505 µg/L). Thyroid volumes in schoolchildren measured by US were within the normal range according to reference values. Median DBS-Tg in schoolchildren was 12.1 µg/L with 3% of Tg values > 40 µg/L. High Tg values were in the UIC range < 50 µg/L and > 300 µg/L (U-shaped curve of Tg plotted against UIC). All children were euthyroid with geometric mean TSH 0.7 ± 0.3 mU/L and arithmetic mean T4 62 ± 12.5 nmol/L. The mean KI content per kg of salt was 24.9 ± 3.1 mg/kg (range 19-36 mg/kg). Study results indicated iodine sufficiency in schoolchildren from the Zagreb area. Thyroglobulin proved to be a sensitive indicator of both iodine deficiency and iodine excess in children. Iodine content in salt from households of schoolchildren was in good compliance with the Croatian act (20-30 mg KI/kg of salt).
Lafrenière, Nelson M; Mudrik, Jared M; Ng, Alphonsus H C; Seale, Brendon; Spooner, Neil; Wheeler, Aaron R
2015-04-07
There is great interest in the development of integrated tools allowing for miniaturized sample processing, including solid phase extraction (SPE). We introduce a new format for microfluidic SPE relying on C18-functionalized magnetic beads that can be manipulated in droplets in a digital microfluidic platform. This format provides the opportunity to tune the amount (and potentially the type) of stationary phase on-the-fly, and allows the removal of beads after the extraction (to enable other operations in same device-space), maintaining device reconfigurability. Using the new method, we employed a design of experiments (DOE) operation to enable automated on-chip optimization of elution solvent composition for reversed phase SPE of a model system. Further, conditions were selected to enable on-chip fractionation of multiple analytes. Finally, the method was demonstrated to be useful for online cleanup of extracts from dried blood spot (DBS) samples. We anticipate this combination of features will prove useful for separating a wide range of analytes, from small molecules to peptides, from complex matrices.
Shimada, Tsutomu; Kelly, Joan; LaMarr, William A; van Vlies, Naomi; Yasuda, Eriko; Mason, Robert W.; Mackenzie, William; Kubaski, Francyne; Giugliani, Roberto; Chinen, Yasutsugu; Yamaguchi, Seiji; Suzuki, Yasuyuki; Orii, Kenji E.; Fukao, Toshiyuki; Orii, Tadao; Tomatsu, Shunji
2014-01-01
Mucopolysaccharidoses (MPS) are caused by deficiency of one of a group of specific lysosomal enzymes, resulting in excessive accumulation of glycosaminoglycans (GAGs). We previously developed GAG assay methods using liquid chromatography tandem mass spectrometry (LC-MS/MS); however, it takes 4–5 min per sample for analysis. For the large numbers of samples in a screening program, a more rapid process is desirable. The automated high-throughput mass spectrometry (HT-MS/MS) system (RapidFire) integrates a solid phase extraction robot to concentrate and desalt samples prior to direction into the MS/MS without chromatographic separation; thereby allowing each sample to be processed within ten seconds (enabling screening of more than one million samples per year). The aim of this study was to develop a higher throughput system to assay heparan sulfate (HS) using HT-MS/MS, and to compare its reproducibility, sensitivity and specificity with conventional LC-MS/MS. HS levels were measured in blood (plasma and serum) from control subjects and patients with MPS II, III, or IV and in dried blood spots (DBS) from newborn controls and patients with MPS I, II, or III. Results obtained from HT-MS/MS showed 1) that there was a strong correlation of levels of disaccharides derived from HS in blood, between those calculated using conventional LC-MS/MS and HT-MS/MS, 2) that levels of HS in blood were significantly elevated in patients with MPS II and III, but not in MPS IVA, 3) that the level of HS in patients with a severe form of MPS II was higher than that in an attenuated form, 4) that reduction of blood HS level was observed in MPS II patients treated with enzyme replacement therapy or hematopoietic stem cell transplantation, and 5) that levels of HS in newborn DBS were elevated in patients with MPS I, II or III, compared to control newborns. In conclusion, HT-MS/MS provides much higher throughput than LC-MS/MS-based methods with similar sensitivity and specificity in an HS assay, indicating that HT-MS/MS may be feasible for diagnosis, monitoring, and newborn screening of MPS. PMID:25092413
SMA Diagnosis: Detection of SMN1 Deletion with Real-Time mCOP-PCR System Using Fresh Blood DNA.
Niba, Emma Tabe Eko; Ar Rochmah, Mawaddah; Harahap, Nur Imma Fatimah; Awano, Hiroyuki; Morioka, Ichiro; Iijima, Kazumoto; Saito, Toshio; Saito, Kayoko; Takeuchi, Atsuko; Lai, Poh San; Bouike, Yoshihiro; Nishio, Hisahide; Shinohara, Masakazu
2017-12-18
Spinal muscular atrophy (SMA) is one of the most common autosomal recessive disorders. The symptoms are caused by defects of lower motor neurons in the spinal cord. More than 95% of SMA patients are homozygous for survival motor neuron 1 (SMN1) deletion. We previously developed a screening system for SMN1 deletion based on a modified competitive oligonucleotide priming-PCR (mCOP-PCR) technique using dried blood spot (DBS) on filter paper. This system is convenient for mass screening in the large population and/or first-tier diagnostic method of the patients in the remote areas. However, this system was still time-consuming and effort-taking, because it required pre-amplification procedure to avoid non-specific amplification and gel-electrophoresis to detect the presence or absence of SMN1 deletion. When the fresh blood samples are used instead of DBS, or when the gel-electrophoresis is replaced by real-time PCR, we may have a simpler and more rapid diagnostic method for SMA. To establish a simpler and more rapid diagnostic method of SMN1 deletion using fresh blood DNA. DNA samples extracted from fresh blood and stored at 4 ℃ for 1 month. The samples were assayed using a real-time mCOP-PCR system without pre-amplification procedures. DNA samples had already been genotyped by PCR-restriction fragment length polymorphism (PCR-RFLP), showing the presence or absence of SMN1 exon 7. The DNA samples were directly subjected to the mCOP-PCR step. The amplification of mCOP-PCR was monitored in a real-time PCR apparatus. The genotyping results of the real-time mCOP-PCR system using fresh blood DNA were completely matched with those of PCR-RFLP. In this real-time mCOP-PCR system using fresh blood-DNA, it took only four hours from extraction of DNA to detection of the presence or absence of SMN1 deletion, while it took more than 12 hours in PCR-RFLP. Our real-time mCOP-PCR system using fresh blood DNA was rapid and accurate, suggesting it may be useful for the first-tier diagnostic method of SMA.
Diouara, Abou Abdallah Malick; Ndiaye, Halimatou Diop; Guindo, Ibrehima; Bangoura, Nestor; Cissé, Mohamed; Edmond, Tchiakpe; Bougoudogo, Flabou; Mboup, Souleymame; Peeters, Martine; Ayouba, Ahidjo; Kane, Ndèye Coumba Touré
2014-01-01
Introduction Access to antiretroviral treatment (ART) becomes more and more effective in resource-limited settings (RLS). However, this global effort would be even more profitable if the access to laboratory services especially in decentralized settings was strengthened. We report the virological outcome and HIV-1 drug resistance in three West African countries using dried blood spots (DBS) samples. Methods We included HIV-1-infected adults on ART ≥6 months and followed up in capital cities and decentralized sites in Senegal, Mali and Guinea-Conakry. Patients were consecutively enrolled and DBS were collected in field conditions and kept at ambient temperature before transfer to the reference laboratory. Viral load (VL) was quantified using the NucliSENS EasyQ HIV-1 v1.2. Genotyping of HIV-1 pol gene was performed using in-house protocol. Results Of the 407 participants, 119, 152 and 136 were from Senegal, Mali and Guinea-Conakry, respectively. The median treatment duration was 36 months [IQR: 6–136]. Virological failure (VF) (VL≥3log10 copies/mL) was observed in 26% (95% confidence interval (CI), 18–35; n=31), 11% (95% CI, 6–17; n=16) and 24% (95% CI, 17–32; n=33) of patients in Senegal, Mali and Guinea-Conakry, respectively (p=0.001). Of samples presenting VL≥3log10 copies/mL (n=80), 70 were successfully genotyped. At least one drug resistance mutation (DRM) was detected in the following proportions: 70% (95% CI, 50–86; n=19), 93% (95% CI, 68–100; n=14) and 68% (95% CI, 48–84; n=19) in Senegal, Mali and Guinea-Conakry, respectively (p=0.22). Twenty-six per cent (26%; 95% CI, 16–38; n=18) of patients in VF harboured wild-type viruses, which is likely indicative of weak adherence. Phylogenetic analysis showed the predominance of CRF02_AG subtype (73%; 95% CI, 61–83; n=51). Conclusions We describe the ART outcome in capital and rural settings of Senegal, Mali and Guinea-Conakry. Our results in all of the three countries highlight the need to reinforce the ART adherence in order to minimize the occurrence of drug resistance. In addition, these findings provide additional evidence that the use of DBS as a sampling support could assist virological monitoring of patients on ART in remote areas. PMID:25527333
Performance evaluation for screening laboratories of the Asia-Pacific region.
Hannon, W Harry
2003-01-01
The Centers for Disease Control and Prevention (CDC) has a long history of involvement in quality assurance (QA) activities for support of newborn screening laboratories. Since 1978, CDC's Newborn Screening Quality Assurance Program (NSQAP), has distributed dried-blood spot (DBS) materials for external QA and has maintained related projects to serve newborn screening laboratories. The first DBS materials were distributed for congenital hypothyroidism screening in 1978 and by 2001, NSQAP had expanded to over 30 disorders and performance monitoring for all filter paper production lots from approved commercial sources. In 2001, there were 250 active NSQAP participants, 167 laboratories from 45 countries and 83 laboratories in the United States. Of these laboratories, 31 are from the Asia Pacific Region representing nine countries primarily for two disorders. In 1999, US laboratories had more errors for Performance Evaluation (PE) specimens than other laboratories; but in 2000, US laboratories had fewer errors. International laboratories reported 0.3% false-negative PE clinical assessments for congenital hypothyroidism and 0.5% for phenylketonuria (0.5%) in 2000. Paperless PE data-reporting operation using an Internet website has recently been implemented.
Yek, Christina; Massanella, Marta; Peling, Tashi; Lednovich, Kristen; Nair, Sangeetha V; Worlock, Andrew; Vargas, Milenka; Gianella, Sara; Ellis, Ronald J; Strain, Matthew C; Busch, Michael P; Nugent, C Thomas; Richman, Douglas D
2017-08-01
The search for a cure for HIV infection has highlighted the need for increasingly sensitive and precise assays to measure viral burden in various tissues and body fluids. We describe the application of a standardized assay for HIV-1 RNA in multiple specimen types. The fully automated Aptima HIV-1 Quant Dx assay (Aptima assay) is FDA cleared for blood plasma HIV-1 RNA quantitation. In this study, the Aptima assay was applied for the quantitation of HIV RNA in peripheral blood mononuclear cells (PBMCs; n = 72), seminal plasma ( n = 20), cerebrospinal fluid (CSF; n = 36), dried blood spots (DBS; n = 104), and dried plasma spots (DPS; n = 104). The Aptima assay was equivalent to or better than commercial assays or validated in-house assays for the quantitation of HIV RNA in CSF and seminal plasma. For PBMC specimens, the sensitivity of the Aptima assay in the detection of HIV RNA decayed as background uninfected PBMC counts increased; proteinase K treatment demonstrated some benefit in restoring signal at higher levels of background PBMCs. Finally, the Aptima assay yielded 100% detection rates of DBS in participants with plasma HIV RNA levels of ≥35 copies/ml and 100% detection rates of DPS in participants with plasma HIV RNA levels of ≥394 copies/ml. The Aptima assay can be applied to a variety of specimens from HIV-infected subjects to measure HIV RNA for studies of viral persistence and cure strategies. It can also detect HIV in dried blood and plasma specimens, which may be of benefit in resource-limited settings.
Gous, Natasha; Scott, Lesley; Berrie, Leigh; Stevens, Wendy
2016-01-01
Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert's random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32-0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services.
Sen, Arko; Heredia, Nicole; Senut, Marie-Claude; Hess, Matthew; Land, Susan; Qu, Wen; Hollacher, Kurt; Dereski, Mary O; Ruden, Douglas M
2015-01-01
Aims In this paper, we tested the hypothesis that early life lead (Pb) exposure associated DNA methylation (5mC) changes are dependent on the sex of the child and can serve as biomarkers for Pb exposure. Methods In this pilot study, we measured the 5mC profiles of DNA extracted from dried blood spots (DBS) in a cohort of 43 children (25 males and 18 females; ages from 3 months to 5 years) from Detroit. Result & Discussion We found that the effect of Pb-exposure on the 5-mC profiles can be separated into three subtypes: affected methylation loci which are conserved irrespective of the sex of the child (conserved); affected methylation loci unique to males (male-specific); and affected methylation loci unique to females (female-specific). PMID:26077427
Xie, Cheng-Long; Shao, Bei; Chen, Jie; Zhou, Yi; Lin, Shi-Yi; Wang, Wen-Wen
2016-01-01
Deep brain stimulation (DBS) is the surgical procedure of choice for patients with advanced Parkinson disease (PD). We aim to evaluate the efficacy of GPi (globus pallidus internus), STN (subthalamic nucleus)-DBS and medical therapy for PD. We conducted a systematic review and multiple-treatments meta-analysis to investigate the efficacy of neurostimulation and medical therapy for PD patients. Sixteen eligible studies were included in this analysis. We pooled the whole data and found obvious difference between GPi-DBS versus medical therapy and STN-DBS versus medical therapy in terms of UPDRS scores (Unified Parkinson’s Disease Rating Scale). Meanwhile, we found GPi-DBS had the similar efficacy on the UPDRS scores when compared with STN-DBS. What is more, quality of life, measured by PDQ-39 (Parkinson’s disease Questionnaire) showed greater improvement after GPi-DBS than STN-DBS. Five studies showed STN-DBS was more effective for reduction in medication than GPi-DBS. Overall, either GPi-DBS or STN-DBS was an effective technique to control PD patients’ symptoms and improved their functionality and quality of life. Meanwhile, the UPDRS scores measuring parkinsonian symptoms revealed no significant difference between GPi-DBS and STN-DBS. STN-DBS was more effective for reduction in medication than GPi-DBS. Alternatively, GPi-DBS was more effective for improving the PDQ-39 score than STN-DBS. PMID:27142183
Motor behaviors in the sheep evoked by electrical stimulation of the subthalamic nucleus.
Lentz, Linnea; Zhao, Yan; Kelly, Matthew T; Schindeldecker, William; Goetz, Steven; Nelson, Dwight E; Raike, Robert S
2015-11-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is used to treat movement disorders, including advanced Parkinson's disease (PD). The pathogenesis of PD and the therapeutic mechanisms of DBS are not well understood. Large animal models are essential for investigating the mechanisms of PD and DBS. The purpose of this study was to develop a novel sheep model of STN DBS and quantify the stimulation-evoked motor behaviors. To do so, a large sample of animals was chronically-implanted with commercial DBS systems. Neuroimaging and histology revealed that the DBS leads were implanted accurately relative to the neurosurgical plan and also precisely relative to the STN. It was also possible to repeatedly conduct controlled evaluations of stimulation-evoked motor behavior in the awake-state. The evoked motor responses depended on the neuroanatomical location of the electrode contact selected for stimulation, as contacts proximal to the STN evoked movements at significantly lower voltages. Tissue stimulation modeling demonstrated that selecting any of the contacts stimulated the STN, whereas selecting the relatively distal contacts often also stimulated thalamus but only the distal-most contact stimulated internal capsule. The types of evoked motor behaviors were specific to the stimulation frequency, as low but not high frequencies consistently evoked movements resembling human tremor or dyskinesia. Electromyography confirmed that the muscle activity underlying the tremor-like movements in the sheep was consistent with human tremor. Overall, this work establishes that the sheep is a viable a large-animal platform for controlled testing of STN DBS with objective motor outcomes. Moreover, the results support the hypothesis that exaggerated low-frequency activity within individual nodes of the motor network can drive symptoms of human movement disorders, including tremor and dyskinesia. Copyright © 2015 Elsevier Inc. All rights reserved.
Determination of a steroid profile in heel prick blood using LC-MS/MS.
Boelen, Anita; Ruiter, An F C; Claahsen-van der Grinten, Hedi L; Endert, Erik; Ackermans, Mariette T
2016-01-01
The aim of this study was to improve the sensitivity of the congenital adrenal hyperplasia (CAH) neonatal screening by including second-tier steroid profiling on a DBS using LC-MS. We developed a method to measure the steroid profile in DBS and established gestational age-specific reference ranges of cortisol, cortisone, 11-deoxycortisol, 21-deoxycortisol, 17-hydroxyprogesterone, testosterone, Δ4-androstenedione, corticosterone and 11-deoxycorticosterone using 450 heel prick samples of neonates, participating in the Dutch Screening Program. Analyzing 92 cards with a positive CAH screening showed that only 21-deoxycortisol was 100% specific for diagnosed CAH patients. Steroid precursors can be measured in DBS and we suggest to implement the method as a second tier testing for CAH in The Netherlands.
Thiel, Daniel B; Platt, Tevah; Platt, Jodyn; King, Susan B; Kardia, Sharon L R
2014-04-01
Biobanks raise challenges for developing ethically sound and practicable consent policies. Biobanks comprised of dried bloodspots (DBS) left over from newborn screening, maintained for long-term storage, and potential secondary research applications are no exception. Michigan has been a leader in transforming its DBS collection, marketing its biobank of de-identified samples for health research use. The Michigan BioTrust for Health includes approximately 4 million unconsented retrospective samples collected as early as 1984 and prospective samples added since the fall of 2010 with blanket parental consent. We engaged Michigan citizens to ascertain public attitudes, knowledge, and beliefs about the BioTrust and informed consent. A convenience sampling of 393 participants from communities around the state of Michigan (oversampling for minority populations) participated in meetings addressing newborn screening, the BioTrust and informed consent, yielding quantitative and qualitative survey and discussion data. Participants affirmed the principle of voluntary informed participation in research and advocated for greater public awareness of the existence of the BioTrust. Most expressed support for the use of DBS for research and a desire for greater involvement in granting permission for research use. Opinions varied as to which specific research uses were acceptable. Participants indicated a desire for greater engagement, public awareness, and more active decision making on the part of biobank participants and parents. Diversity of opinion over which research areas were deemed acceptable problematizes the blanket consent model that currently applies to the BioTrust's prospective DBS collection and that could become the new norm for research using de-identified data under proposed changes to the Common Rule.
Keller, Marla J; Mesquita, Pedro M; Marzinke, Mark A; Teller, Ryan; Espinoza, Lilia; Atrio, Jessica M; Lo, Yungtai; Frank, Bruce; Srinivasan, Sujatha; Fredricks, David N; Rabe, Lorna; Anderson, Peter L; Hendrix, Craig W; Kiser, Patrick F; Herold, Betsy C
2016-03-13
Tenofovir disoproxil fumarate (TDF), a prodrug of tenofovir (TFV), may be ideal for topical HIV preexposure prophylaxis because it has higher tissue and cell permeability than TFV; is not adversely impacted by seminal proteins; and its active metabolite, TFV-diphosphate (TFV-DP), has a long intracellular half-life. We engineered a TDF eluting polyurethane reservoir intravaginal ring (IVR) to provide near constant mucosal antiretroviral concentrations. A first-in-human randomized placebo-controlled trial was conducted to assess the safety and pharmacokinetics of the TDF IVR in healthy, sexually abstinent women (15 TDF and 15 placebo). Drug concentrations were measured in cervicovaginal fluid (CVF) obtained by swab, cervical tissue, plasma, and dried blood spots (DBS) over 14 days of continuous ring use. There were 43 total, 23 reproductive tract, and eight product-related grade 1 adverse events. Steady-state CVF TFV concentrations were achieved proximal (vagina, ectocervix) and distal (introitus) to the TDF IVR 1 day after ring insertion. Median tissue TFV-DP concentrations 14 days after TDF IVR placement were 120 fmol/mg (interquartile range 90, 550). CVF collected from the cervix 1 week and 2 weeks after TDF IVR insertion provided significant protection against ex-vivo HIV challenge. Eleven of 14 (78%) participants had detectable TFV-DP DBS concentrations 14 days after TDF IVR placement, suggesting that DBS may provide a surrogate marker of adherence in future clinical trials. A TDF IVR is safe, well tolerated, and results in mucosal TFV concentrations that exceed those associated with HIV protection. The findings support further clinical evaluation of this TDF IVR.
New multiplex real-time PCR approach to detect gene mutations for spinal muscular atrophy.
Liu, Zhidai; Zhang, Penghui; He, Xiaoyan; Liu, Shan; Tang, Shi; Zhang, Rong; Wang, Xinbin; Tan, Junjie; Peng, Bin; Jiang, Li; Hong, Siqi; Zou, Lin
2016-08-17
Spinal muscular atrophy (SMA) is the most common autosomal recessive disease in children, and the diagnosis is complicated and difficult, especially at early stage. Early diagnosis of SMA is able to improve the outcome of SMA patients. In our study, Real-time PCR was developed to measure the gene mutation or deletion of key genes for SMA and to further analyse genotype-phenotype correlation. The multiple real-time PCR for detecting the mutations of survival of motor neuron (SMN), apoptosis inhibitory protein (NAIP) and general transcription factor IIH, polypeptide 2 gene (GTF2H2) was established and confirmed by DNA sequencing and multiplex ligation-dependent probe amplification (MLPA). The diagnosis and prognosis of 141 hospitalized children, 100 normal children and further 2000 cases of dry blood spot (DBS) samples were analysed by this multiple real-time PCR. The multiple real-time PCR was established and the accuracy of it to detect the mutations of SMN, NAIP and GTF2H2 was at least 98.8 % comparing with DNA sequencing and MLPA. Among 141 limb movement disorders children, 75 cases were SMA. 71 cases of SMA (94.67 %) were with SMN c.840 mutation, 9 cases (12 %) with NAIP deletion and 3 cases (4 %) with GTF2H2 deletion. The multiple real-time PCR was able to diagnose and predict the prognosis of SMA patients. Simultaneously, the real-time PCR was applied to detect trace DNA from DBS and able to make an early diagnosis of SMA. The clinical and molecular characteristics of SMA in Southwest of China were presented. Our work provides a novel way for detecting SMA in children by using real-time PCR and the potential usage in newborn screening for early diagnosis of SMA.
Yek, Christina; Massanella, Marta; Peling, Tashi; Lednovich, Kristen; Nair, Sangeetha V.; Worlock, Andrew; Vargas, Milenka; Gianella, Sara; Ellis, Ronald J.; Strain, Matthew C.; Busch, Michael P.; Nugent, C. Thomas
2017-01-01
ABSTRACT The search for a cure for HIV infection has highlighted the need for increasingly sensitive and precise assays to measure viral burden in various tissues and body fluids. We describe the application of a standardized assay for HIV-1 RNA in multiple specimen types. The fully automated Aptima HIV-1 Quant Dx assay (Aptima assay) is FDA cleared for blood plasma HIV-1 RNA quantitation. In this study, the Aptima assay was applied for the quantitation of HIV RNA in peripheral blood mononuclear cells (PBMCs; n = 72), seminal plasma (n = 20), cerebrospinal fluid (CSF; n = 36), dried blood spots (DBS; n = 104), and dried plasma spots (DPS; n = 104). The Aptima assay was equivalent to or better than commercial assays or validated in-house assays for the quantitation of HIV RNA in CSF and seminal plasma. For PBMC specimens, the sensitivity of the Aptima assay in the detection of HIV RNA decayed as background uninfected PBMC counts increased; proteinase K treatment demonstrated some benefit in restoring signal at higher levels of background PBMCs. Finally, the Aptima assay yielded 100% detection rates of DBS in participants with plasma HIV RNA levels of ≥35 copies/ml and 100% detection rates of DPS in participants with plasma HIV RNA levels of ≥394 copies/ml. The Aptima assay can be applied to a variety of specimens from HIV-infected subjects to measure HIV RNA for studies of viral persistence and cure strategies. It can also detect HIV in dried blood and plasma specimens, which may be of benefit in resource-limited settings. PMID:28592548
Cognitive Activation by Central Thalamic Stimulation: The Yerkes-Dodson Law Revisited.
Mair, Robert G.; Onos, Kristen D.; Hembrook, Jacqueline R.
2011-01-01
Central thalamus regulates forebrain arousal, influencing activity in distributed neural networks that give rise to organized actions during alert, wakeful states. Central thalamus has been implicated in working memory by the effects of lesions and microinjected drugs in this part of the brain. Lesions and drugs that inhibit neural activity have been found to impair working memory. Drugs that increase activity have been found to enhance and impair memory depending on the dose tested. Electrical deep brain stimulation (DBS) similarly enhances working memory at low stimulating currents and impairs it at higher currents. These effects are time dependent. They were observed when DBS was applied during the memory delay (retention) or choice response (retrieval) but not earlier in trials during the sample (acquisition) phase. The effects of microinjected drugs and DBS are consistent with the Yerkes-Dodson law, which describes an inverted-U relationship between arousal and behavioral performance. Alternatively these results may reflect desensitization associated with higher levels of stimulation, spread of drugs or current to adjacent structures, or activation of less sensitive neurons or receptors at higher DBS currents or drug doses. PMID:22013395
NASA Astrophysics Data System (ADS)
Robert, Romain; Robion, Philippe; David, Christian; Souloumiac, Pauline; Saillet, Elodie
2017-04-01
In high porosity sandstone lithologies, deformation bands (DBs) are characterized by changes in micro-structural characteristics inducing a localized change in the petrophysical properties of the rock. These DBs, which are generally tabular structures from millimeters to few centimeters thick, can be used at the field scale to decipher extensional or compactional tectonic regime. However, numerous parameters in addition to the tectonic regime may affect development of DBs, and particularly the evolution of porosity during burial history. The aim of this work is to understand the relationship between the DBs occurrence in tectonic shortening regime and the timing of grain cementation that occurs during burial for an analogue to siliciclastic reservoir. For that purpose, we have focused our analysis on the Aren syn-tectonic sandstone formation, maastrichtian in age, localized on the front of the Boixols thrust, on the southern side of the Sant Corneli anticline, in the south central Pyrenees (Spain). The outcrops are localized in the Tremp-Graus basin, all along a 30 km East-West trend where 10 different sites, in which deformation bands are observable, have been investigated and sampled. The structural geometry of the basin is constrained with 3 serial N-S oriented cross sections showing an increase of the shortening from West to East. Our field work strategy was to, 1) measure the orientation of the DBs in each site, 2) take cores both within the DBs and the host rock to conduct systematic thin section investigations, and 3) take oriented cores in order to study the magnetic fabric giving informations on the internal deformation linked to a set of deformation band and regional N-S shortening. Field data show a minimum of two sets of DBs on each site with variation of orientations and densities. These DBs are perpendicular to the strata which prove their early occurrence, recording the initial stages of local deformation and evolution of the Boixols fold and thrust. At the microstructures scale, DBs are characterized by grain crushing with hertzian fractures associated with pore collapse. All these evidences allow us to define these structures as compaction bands. Further microscopical investigation, grain size distribution and initial porosity are determined by image analysis. These data are confronted to geomechanical models in order to investigate the relationship between the occurrences of DBs in the burial history and the diagenesis of the rock during the compressive event.
NASA Astrophysics Data System (ADS)
Yang, Chun; Quarles, C. A.
2007-10-01
We have used positron Doppler Broadening Spectroscopy (DBS) to investigate the uniformity of rubber-carbon black composite samples. The amount of carbon black added to a rubber sample is characterized by phr, the number of grams of carbon black per hundred grams of rubber. Typical concentrations in rubber tires are 50 phr. It has been shown that the S parameter measured by DBS depends on the phr of the sample, so the variation in carbon black concentration can be easily measured to 0.5 phr. In doing the experiments we observed a dependence of the S parameter on small variation in the counting rate or deadtime. By carefully calibrating this deadtime correction we can significantly reduce the experimental run time and thus make faster determination of the uniformity of extended samples.
Rughani, Anand; Schwalb, Jason M; Sidiropoulos, Christos; Pilitsis, Julie; Ramirez-Zamora, Adolfo; Sweet, Jennifer A; Mittal, Sandeep; Espay, Alberto J; Martinez, Jorge Gonzalez; Abosch, Aviva; Eskandar, Emad; Gross, Robert; Alterman, Ron; Hamani, Clement
2018-06-01
Is bilateral subthalamic nucleus deep brain stimulation (STN DBS) more, less, or as effective as bilateral globus pallidus internus deep brain stimulation (GPi DBS) in treating motor symptoms of Parkinson's disease, as measured by improvements in Unified Parkinson's Disease Rating Scale, part III (UPDRS-III) scores? Given that bilateral STN DBS is at least as effective as bilateral GPi DBS in treating motor symptoms of Parkinson's disease (as measured by improvements in UPDRS-III scores), consideration can be given to the selection of either target in patients undergoing surgery to treat motor symptoms. (Level I). Is bilateral STN DBS more, less, or as effective as bilateral GPi DBS in allowing reduction of dopaminergic medication in Parkinson's disease? When the main goal of surgery is reduction of dopaminergic medications in a patient with Parkinson's disease, then bilateral STN DBS should be performed instead of GPi DBS. (Level I). Is bilateral STN DBS more, less, or as effective as bilateral GPi DBS in treating dyskinesias associated with Parkinson's disease? There is insufficient evidence to make a generalizable recommendation regarding the target selection for reduction of dyskinesias. However, when the reduction of medication is not anticipated and there is a goal to reduce the severity of "on" medication dyskinesias, the GPi should be targeted. (Level I). Is bilateral STN DBS more, less, or as effective as bilateral GPi DBS in improving quality of life measures in Parkinson's disease? When considering improvements in quality of life in a patient undergoing DBS for Parkinson's disease, there is no basis to recommend bilateral DBS in 1 target over the other. (Level I). Is bilateral STN DBS associated with greater, lesser, or a similar impact on neurocognitive function than bilateral GPi DBS in Parkinson disease? If there is significant concern about cognitive decline, particularly in regards to processing speed and working memory in a patient undergoing DBS, then the clinician should consider using GPi DBS rather than STN DBS, while taking into consideration other goals of surgery. (Level I). Is bilateral STN DBS associated with a higher, lower, or similar risk of mood disturbance than GPi DBS in Parkinson's disease? If there is significant concern about the risk of depression in a patient undergoing DBS, then the clinician should consider using pallidal rather than STN stimulation, while taking into consideration other goals of surgery. (Level I). Is bilateral STN DBS associated with a higher, lower, or similar risk of adverse events compared to GPi DBS in Parkinson's disease? There is insufficient evidence to recommend bilateral DBS in 1 target over the other in order to minimize the risk of surgical adverse events. The full guideline can be found at: https://www.cns.org/guidelines/deep-brain-stimulation-parkinsons-disease.
Liu, Qian; Wu, Jing; Shen, Wen; Wei, Ran; Jiang, Jianhui; Liang, Jinqun; Chen, Min; Zhong, Mei; Yin, Aihua
2017-11-01
To analyze the amino acids (AA) and acyl carnitine (AC) profiles in dry blood spot (DBS) specimens of low birth weight (LBW), preterm birth (PTB), and small for gestational age (SGA), and to compare the concentration difference of AA and AC with those without above. This is a retrospectively study. Eight thousand nine hundred and seventy-nine uncomplicated pregnant newborns were enrolled into the study. DBS were collected on the third day of life, and concentrations of 11 types of AA, free carnitine and 30 types of AC were detected by using high-performance liquid chromatography tandem mass spectrometry (HPLC-MS). Shapiro-Wilk test and Kruskal-Wallis rank test were applied in statistical analysis. Concentrations of most AA and AC in infants born in SGA were significantly higher than those in non-SGA group, while lower in LBW and PTB groups than those in non-LBW and non-PTB groups (p < 0.05). The difference of concentration of AA and AC in the subgroups suggested there may be a dysutilization of AA and AC in SGA, but an inborn insufficient of AA and AC in LBW and PTB neonates.
Asleep Deep Brain Stimulation Reduces Incidence of Intracranial Air during Electrode Implantation.
Ko, Andrew L; Magown, Philippe; Ozpinar, Alp; Hamzaoglu, Vural; Burchiel, Kim J
2018-05-30
Asleep deep brain stimulation (aDBS) implantation replaces microelectrode recording for image-guided implantation, shortening the operative time and reducing cerebrospinal fluid egress. This may decrease pneumocephalus, thus decreasing brain shift during implantation. To compare the incidence and volume of pneumocephalus during awake (wkDBS) and aDBS procedures. A retrospective review of bilateral DBS cases performed at Oregon Health & Science University from 2009 to 2017 was undertaken. Postimplantation imaging was reviewed to determine the presence and volume of intracranial air and measure cortical brain shift. Among 371 patients, pneumocephalus was noted in 66% of wkDBS and 15.6% of aDBS. The average volume of air was significantly higher in wkDBS than aDBS (8.0 vs. 1.8 mL). Volumes of air greater than 7 mL, which have previously been linked to brain shift, occurred significantly more frequently in wkDBS than aDBS (34 vs 5.6%). wkDBS resulted in significantly larger cortical brain shifts (5.8 vs. 1.2 mm). We show that aDBS reduces the incidence of intracranial air, larger air volumes, and cortical brain shift. Large volumes of intracranial air have been correlated to shifting of brain structures during DBS procedures, a variable that could impact accuracy of electrode placement. © 2018 S. Karger AG, Basel.
NASA Astrophysics Data System (ADS)
Zhang, Hui; Wen, Xing; Wang, Yingxia
2007-05-01
Inorganic sulfate- and organic dodecylbenzenesulfonate (DBS)-intercalated zinc-iron layered double hydroxides (LDHs) materials were prepared by one-step coprecipitation method from a mixed salt solutions containing Zn(II), Fe(II) and Fe(III) salts. The as-prepared samples have been characterized by X-ray powder diffraction (XRD), Fourier-transform infrared spectroscopy (FT-IR), low-temperature nitrogen adsorption, scanning electron microscopy (SEM), inductively coupled plasma emission spectroscopy (ICP), and Mössbauer spectroscopy (MS). The XRD analyses demonstrate the typical LDH-like layered structural characteristics of both products. The room temperature MS results reveal the characteristics of both the Fe(II) and Fe(III) species for SO 42--containing product, while only the Fe(III) characteristic for DBS-containing one. The combination characterization results and Rietveld analysis illustrate that the SO 42--containing product possesses the Green Rust two (GR2)-like crystal structure with an approximate chemical composition of [Zn 0.435·Fe II0.094·Fe III0.470·(OH) 2]·(SO 42-) 0.235·1.0H 2O, while the DBS-containing one exhibits the common LDH compound-like structure. The contact angle measurement indicates the evident hydrophobic properties of DBS-containing nanocomposite, compared with SO 42--containing product, due to the modification of the internal and external surface of LDHs by the organic hydrophobic chain of DBS.
Facilitating effects of deep brain stimulation on feedback learning in Parkinson's disease.
Meissner, Sarah Nadine; Südmeyer, Martin; Keitel, Ariane; Pollok, Bettina; Bellebaum, Christian
2016-10-15
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) provides an effective treatment for Parkinson's disease (PD) motor symptoms. However, findings of effects on cognitive function such as feedback learning remain controversial and rare. The aim of the present study was to gain a better understanding of cognitive alterations associated with STN-DBS. Therefore, we investigated effects of STN-DBS on active and observational feedback learning in PD. 18 PD patients with STN-DBS and 18 matched healthy controls completed active and observational feedback learning tasks. Patients were investigated ON and OFF STN-DBS. Tasks consisted of learning (with feedback) and test phases (without feedback). STN-DBS improved active learning during feedback trials and PD patients ON (but not OFF) STN-DBS showed comparable performance patterns as healthy controls. No STN-DBS effect was found when assessing performance during active test trials without feedback. In this case, however, STN-DBS effects were found to depend on symptom severity. While more impaired patients benefited from STN-DBS, stimulation had no facilitating effect on patients with less severe symptoms. Along similar lines, the severity of motor symptoms tended to be significantly correlated with differences in active test performance due to STN-DBS. For observational feedback learning, there was a tendency for a positive STN-DBS effect with patients reaching the performance level of healthy controls only ON STN-DBS. The present data suggest that STN-DBS facilitates active feedback learning in PD patients. Furthermore, they provide first evidence that STN-DBS might not only affect learning from own but also from observed actions and outcomes. Copyright © 2016 Elsevier B.V. All rights reserved.
Dinkelbach, Lars; Möller, Bettina; Witt, Karsten; Schnitzler, Alfons; Südmeyer, Martin
2017-02-21
The introduction of deep brain stimulation (DBS) about 25 years ago provided one of the major breakthroughs in the treatment of Parkinson's disease (PD). However, a high percentage of patients are reluctant to undergo DBS. Previous research revealed that the critical step on the patient's path to DBS is the decision whether to undergo further diagnostic assessment for surgery at a specialized DBS-center. The aims of the current study were to evaluate how effective the combination of an outpatient DBS screening tool, STIMULUS, with specially developed educational material was to enhance patient education on DBS and to identify motivational aspects which influenced the patients' willingness to undergo further assessment. In total, 264 patients were identified as appropriate candidates for DBS by general neurologists using the electronic preselection tool STIMULUS. Patient-centered information material was designed and handed out to support education on DBS. Further, several clinical characteristics and details of the patient counseling were documented. Refusal or consent to show up at a DBS center was registered over the following 16 months. 114 (43.2%) patients preselected as eligible for DBS (STIMULUS Score ≥ 6) agreed to show up at a specialized DBS center to undergo further diagnostic assessment. The patients' ages, PD classification as an akinetic-rigid type and the talks' topics side-effects of dopaminergic medication and the optimal time frame had a significant influence on the patients' decisions. The combination of preselection tools as STIMULUS with comprehensive information material is effective to increase DBS-acceptance rate in PD patients. Important topics of the information about DBS cover the optimal time frame for DBS surgery, the side-effects of dopaminergic medication as well as side-effects and complications of DBS surgery.
Chard, Anna N; Trinies, Victoria; Moss, Delynn M; Chang, Howard H; Doumbia, Seydou; Lammie, Patrick J; Freeman, Matthew C
2018-04-01
Evidence from recent studies assessing the impact of school water, sanitation and hygiene (WASH) interventions on child health has been mixed. Self-reports of disease are subject to bias, and few WASH impact evaluations employ objective health measures to assess reductions in disease and exposure to pathogens. We utilized antibody responses from dried blood spots (DBS) to measure the impact of a school WASH intervention on infectious disease among pupils in Mali. We randomly selected 21 beneficiary primary schools and their 21 matched comparison schools participating in a matched-control trial of a comprehensive school-based WASH intervention in Mali. DBS were collected from 20 randomly selected pupils in each school (n = 807). We analyzed eluted IgG from the DBS using a Luminex multiplex bead assay to 28 antigens from 17 different pathogens. Factor analysis identified three distinct latent variables representing vector-transmitted disease (driven primarily by dengue), food/water-transmitted enteric disease (driven primarily by Escherichia coli and Vibrio cholerae), and person-to-person transmitted enteric disease (driven primarily by norovirus). Data were analyzed using a linear latent variable model. Antibody evidence of food/water-transmitted enteric disease (change in latent variable mean (β) = -0.24; 95% CI: -0.53, -0.13) and person-to-person transmitted enteric disease (β = -0.17; 95% CI: -0.42, -0.04) was lower among pupils attending beneficiary schools. There was no difference in antibody evidence of vector-transmitted disease (β = 0.11; 95% CI: -0.05, 0.33). Evidence of enteric disease was lower among pupils attending schools benefitting from school WASH improvements than students attending comparison schools. These findings support results from the parent study, which also found reduced incidence of self-reported diarrhea among pupils of beneficiary schools. DBS collection was feasible in this resource-poor field setting and provided objective evidence of disease at a low cost per antigen analyzed, making it an effective measurement tool for the WASH field. The trial was registered at ClinicalTrials.gov (NCT01787058).
Gous, Natasha; Scott, Lesley; Berrie, Leigh; Stevens, Wendy
2016-01-01
Background Expansion of HIV viral load (VL) testing services are required to meet increased targets for monitoring patients on antiretroviral treatment. South Africa currently tests >4million VLs per annum in 16 highly centralised, automated high-throughput laboratories. The Xpert HIV-1 VL assay (Cepheid) was evaluated against in-country predicates, the Roche Cobas Taqmanv2 and Abbott HIV-1RT, to investigate options for expanding VL testing using GeneXpert’s random access, polyvalent capabilities and already established footprint in South Africa with the Xpert MTB/RIF assay (207 sites). Additionally, the performance of Xpert HIV-1VL on alternative, off-label specimen types, Dried Blood Spots (DBS) and whole blood, was investigated. Method Precision, accuracy (agreement) and clinical misclassification (1000cp/ml) of Xpert HIV-1VL plasma was compared to Taqmanv2 (n = 155) and Abbott HIV-1 RT (n = 145). Misclassification of Xpert HIV-1VL was further tested on DBS (n = 145) and whole blood (n = 147). Results Xpert HIV-1VL demonstrated 100% concordance with predicate platforms on a standardised frozen, plasma panel (n = 42) and low overall percentage similarity CV of 1.5% and 0.9% compared to Taqmanv2 and Abbott HIV-1 RT, respectively. On paired plasma clinical specimens, Xpert HIV-1VL had low bias (SD 0.32–0.37logcp/ml) and 3% misclassification at the 1000cp/ml threshold compared to Taqmanv2 (fresh) and Abbott HIV-1 RT (frozen), respectively. Xpert HIV-1VL on whole blood and DBS increased misclassification (upward) by up to 14% with increased invalid rate. All specimen testing was easy to perform and compatible with concurrent Xpert MTB/RIF Tuberculosis testing on the same instrument. Conclusion The Xpert HIV-1VL on plasma can be used interchangeably with existing predicate platforms in South Africa. Whole blood and DBS testing requires further investigation, but polyvalency of the GeneXpert offers a solution to extending VL testing services. PMID:27992495
Trinies, Victoria; Doumbia, Seydou; Lammie, Patrick J.; Freeman, Matthew C.
2018-01-01
Background Evidence from recent studies assessing the impact of school water, sanitation and hygiene (WASH) interventions on child health has been mixed. Self-reports of disease are subject to bias, and few WASH impact evaluations employ objective health measures to assess reductions in disease and exposure to pathogens. We utilized antibody responses from dried blood spots (DBS) to measure the impact of a school WASH intervention on infectious disease among pupils in Mali. Methodology/Principal findings We randomly selected 21 beneficiary primary schools and their 21 matched comparison schools participating in a matched-control trial of a comprehensive school-based WASH intervention in Mali. DBS were collected from 20 randomly selected pupils in each school (n = 807). We analyzed eluted IgG from the DBS using a Luminex multiplex bead assay to 28 antigens from 17 different pathogens. Factor analysis identified three distinct latent variables representing vector-transmitted disease (driven primarily by dengue), food/water-transmitted enteric disease (driven primarily by Escherichia coli and Vibrio cholerae), and person-to-person transmitted enteric disease (driven primarily by norovirus). Data were analyzed using a linear latent variable model. Antibody evidence of food/water-transmitted enteric disease (change in latent variable mean (β) = -0.24; 95% CI: -0.53, -0.13) and person-to-person transmitted enteric disease (β = -0.17; 95% CI: -0.42, -0.04) was lower among pupils attending beneficiary schools. There was no difference in antibody evidence of vector-transmitted disease (β = 0.11; 95% CI: -0.05, 0.33). Conclusions/Significance Evidence of enteric disease was lower among pupils attending schools benefitting from school WASH improvements than students attending comparison schools. These findings support results from the parent study, which also found reduced incidence of self-reported diarrhea among pupils of beneficiary schools. DBS collection was feasible in this resource-poor field setting and provided objective evidence of disease at a low cost per antigen analyzed, making it an effective measurement tool for the WASH field. Trial registration The trial was registered at ClinicalTrials.gov (NCT01787058) PMID:29659574
Holguín, Africa; Erazo, Karen; Escobar, Gustavo; de Mulder, Miguel; Yebra, Gonzalo; Martín, Leticia; Jovel, Luis Enrique; Castaneda, Luis; Pérez, Elsy
2011-05-01
Emergence of viral resistance is a major obstacle for antiretroviral treatment (ART) effectiveness. Human immunodeficiency virus type-1 (HIV-1) variants and drug-resistance mutations were identified in naive and antiretroviral drug-experienced children with virologic failure, in Honduras and El Salvador. Dried blood spots (DBS) from 80 individuals (54 from Honduras, 26 from El Salvador) infected during their childhood between 1989 and 2009 were collected in 2009. The HIV pol region was amplified and sequenced to identify antiretroviral-resistant mutations according to the 2009 International AIDS Society. The genotypic drug resistance interpretation was performed using the Stanford algorithm. HIV-1 variants were characterized by phylogenetic analysis and subtyping tools. HIV-1 protease and reverse transcription sequences were obtained from DBS specimens in 71 and 66 patients, respectively, of the 80 patients. All children were native Central Americans carrying subtype B, with a mean age of 9 years, most were male (65%), perinatally infected (96%), with moderate/severe AIDS symptoms (70%), and receiving first line ART at the time of sequencing (65%). Diagnostic delay was frequently observed. Infected children from Honduras presented longer ART experience and clinical outcomes, and more frequent severe symptoms. Resistant variants infected 1 of 11 naive children from El Salvador but none of the perinatally infected naive children from Honduras. Resistance was higher among ART-exposed individuals in both countries and similar for protease inhibitors (16%), nucleoside reverse transcription inhibitors (44%-52%), and nonnucleoside reverse-transcription inhibitors (66.7%). One in 10 pretreated children in each country was infected with resistant viruses to the 3 drug families. Our data support the need for continued surveillance of resistance patterns using DBS at national levels among naive and pretreated children to optimize the ART regimens.
Metherel, Adam H; Aristizabal Henao, Juan J; Ciobanu, Flaviu; Taha, Ameer Y; Stark, Ken D
2015-09-01
Dried blood spots (DBS) by fingertip prick collection for fatty acid profiling are becoming increasingly popular due to ease of collection, minimal invasiveness and its amenability to high-throughput analyses. Herein, we assess a microwave-assisted direct transesterification method for the production of fatty acid methyl esters (FAME) from DBS. Technical replicates of human whole blood were collected and 25-μL aliquots were applied to chromatography strips prior to analysis by a standard 3-h transesterification method or microwave-assisted direct transesterification method under various power (variable vs constant), time (1-5 min) and reagent (1-10% H2SO4 in methanol) conditions. In addition, a standard method was compared to a 5-min, 30-W power microwave in 1% H2SO4 method for FAME yield from whole blood sphingomyelin, and sphingomyelin standards alone and spiked in whole blood. Microwave-assisted direct transesterification yielded no significant differences in both quantitative (nmol/100 µL) and qualitative (mol%) fatty acid assessments after as little as 1.5- and 1-min reaction times, respectively, using the variable power method and 5% H2SO4 in methanol. However, 30-W power for 5 min increased total FAME yield of the technical replicates by 14%. This increase appears largely due to higher sphingomyelin-derived FAME yield of up to 109 and 399% compared to the standard method when determined from whole blood or pure standards, respectively. In conclusion, microwave-assisted direct transesterification of DBS achieved in as little as 1-min, and 5-min reaction times increase total fatty acids primarily by significantly improving sphingomyelin-derived fatty acid yield.
Screening of carnitine and biotin deficiencies on tandem mass spectrometry.
Hagiwara, Shin-Ichiro; Kubota, Mitsuru; Nambu, Ryusuke; Kagimoto, Seiichi
2017-04-01
It is important to assess pediatric patients for nutritional deficiency when they are receiving specific interventions, such as enteral feeding. We focused on measurement of C0 and 3-hydroxyisovalerylcarnitine (C5-OH) with tandem mass spectrometry (MS/MS), which is performed as part of the newborn mass screening. The purpose of this study was to investigate the usefulness of MS/MS for screening carnitine and biotin deficiencies. Forty-two children (24 boys, 18 girls) were enrolled between December 2013 and December 2015. Blood tests, including measurement of serum free carnitine via the enzyme cycling method, and acylcarnitine analysis on MS/MS of dried blood spot (DBS), were performed for the evaluation of nutrition status. Median patient age was 2 years (range, 2 months-14 years). Mean serum free carnitine was 41.8 ± 19.2 μmol/L. In six of the 42 patients, serum free carnitine was <20 μmol/L (range, 4.0-18.7 μmol/L). C0 and C5-OH measured on MS/MS of DBS were 33.8 ± 20.2 nmol/mL and 0.48 ± 0.22 nmol/mL, respectively. There was a strong positive correlation (r = 0.89, P < 0.001) between serum free carnitine and C0 measured on the same day. In one patient on hydrolyzed formula, C5-OH was >1.00 nmol/L. Therapy-resistant eczema was improved by treatment with additional biotin and a non-hydrolyzed formula. C0 and C5-OH, measured on MS/MS of DBS, were useful for screening carnitine and biotin deficiencies. © 2016 Japan Pediatric Society.
Huang, Hung-Yu; Hsu, Yi-Ting; Wu, Yu-Chin; Chiou, Shang-Ming; Kao, Chia-Hung; Tsai, Mu-Chieh; Tsai, Chon-Haw
2012-06-01
To illustrate the beneficial effect of zolpidem on the neuropsychiatric and motor symptoms in a patient with Parkinson disease (PD) after bilateral subthalamic nucleus deep brain stimulation. The 61-year-old housewife was diagnosed to have PD for 12 years with initial presentation of clumsiness and rest tremor of right limbs. She was referred to our hospital in March 2009 due to shortening of drug beneficial period since 3 years ago and on-phase dyskinesia in recent 2 years. Bilateral STN DBS was conducted on 18 June, 2009. Fluctuating spells of mental confusion were developed on the next day after surgery. Electric stimuli via DBS electrodes were delivered with parameters of 2 volts, 60 μs, 130 Hz on bilateral STN 32 days after DBS. The incoherent behaviors and motor fluctuation remained to occur. The beneficial effect of zolpidem on her neuropsychiatric and motor symptoms was detected incidentally in early July 2009. She could chat normally with her caregiver and walk with assistance after taking zolpidem. The beneficial period may last for 2 hours. Zolpidem was then given in dosage of 10 mg three times per day. The neuropsychiatric inventory was scored 56 during zolpidem 'off' and 30 during zolpidem 'on'. To understand the intriguing feature, we conducted FDG-PET during 'off' and 'on' zolpidem conditions. The results revealed that the metabolism was decreased in the right frontal, parietal cortex and caudate nucleus during zolpidem 'off'. These cool spots can be partially restored by zolpidem. Zolpidem ameliorated the neuropsychiatric and parkinsonian motor symptom in the PD patient. Since GABAA benzodiazepine receptors are widely distributed throughout the central nervous system, zolpidem probably acts via modulating structures lying within the cortico-subcortical loop or by direct effect on these cortical regions.
Wang, Ching-Fu; Yang, Shih-Hung; Lin, Sheng-Huang; Chen, Po-Chuan; Lo, Yu-Chun; Pan, Han-Chi; Lai, Hsin-Yi; Liao, Lun-De; Lin, Hui-Ching; Chen, Hsu-Yan; Huang, Wei-Chen; Huang, Wun-Jhu; Chen, You-Yin
Deep brain stimulation (DBS) has been applied as an effective therapy for treating Parkinson's disease or essential tremor. Several open-loop DBS control strategies have been developed for clinical experiments, but they are limited by short battery life and inefficient therapy. Therefore, many closed-loop DBS control systems have been designed to tackle these problems by automatically adjusting the stimulation parameters via feedback from neural signals, which has been reported to reduce the power consumption. However, when the association between the biomarkers of the model and stimulation is unclear, it is difficult to develop an optimal control scheme for other DBS applications, i.e., DBS-enhanced instrumental learning. Furthermore, few studies have investigated the effect of closed-loop DBS control for cognition function, such as instrumental skill learning, and have been implemented in simulation environments. In this paper, we proposed a proof-of-principle design for a closed-loop DBS system, cognitive-enhancing DBS (ceDBS), which enhanced skill learning based on in vivo experimental data. The ceDBS acquired local field potential (LFP) signal from the thalamic central lateral (CL) nuclei of animals through a neural signal processing system. A strong coupling of the theta oscillation (4-7 Hz) and the learning period was found in the water reward-related lever-pressing learning task. Therefore, the theta-band power ratio, which was the averaged theta band to averaged total band (1-55 Hz) power ratio, could be used as a physiological marker for enhancement of instrumental skill learning. The on-line extraction of the theta-band power ratio was implemented on a field-programmable gate array (FPGA). An autoregressive with exogenous inputs (ARX)-based predictor was designed to construct a CL-thalamic DBS model and forecast the future physiological marker according to the past physiological marker and applied DBS. The prediction could further assist the design of a closed-loop DBS controller. A DBS controller based on a fuzzy expert system was devised to automatically control DBS according to the predicted physiological marker via a set of rules. The simulated experimental results demonstrate that the ceDBS based on the closed-loop control architecture not only reduced power consumption using the predictive physiological marker, but also achieved a desired level of physiological marker through the DBS controller. Copyright © 2017 Elsevier Inc. All rights reserved.
McConnell, George C; So, Rosa Q; Grill, Warren M
2016-06-01
Subthalamic nucleus (STN) deep brain stimulation (DBS) is an established treatment for the motor symptoms of Parkinson's disease (PD). However, the mechanisms of action of DBS are unknown. Random temporal patterns of DBS are less effective than regular DBS, but the neuronal basis for this dependence on temporal pattern of stimulation is unclear. Using a rat model of PD, we quantified the changes in behavior and single-unit activity in globus pallidus externa and substantia nigra pars reticulata during high-frequency STN DBS with different degrees of irregularity. Although all stimulus trains had the same average rate, 130-Hz regular DBS more effectively reversed motor symptoms, including circling and akinesia, than 130-Hz irregular DBS. A mixture of excitatory and inhibitory neuronal responses was present during all stimulation patterns, and mean firing rate did not change during DBS. Low-frequency (7-10 Hz) oscillations of single-unit firing times present in hemiparkinsonian rats were suppressed by regular DBS, and neuronal firing patterns were entrained to 130 Hz. Irregular patterns of DBS less effectively suppressed 7- to 10-Hz oscillations and did not regularize firing patterns. Random DBS resulted in a larger proportion of neuron pairs with increased coherence at 7-10 Hz compared with regular 130-Hz DBS, which suggested that long pauses (interpulse interval >50 ms) during random DBS facilitated abnormal low-frequency oscillations in the basal ganglia. These results suggest that the efficacy of high-frequency DBS stems from its ability to regularize patterns of neuronal firing and thereby suppress abnormal oscillatory neural activity within the basal ganglia. Copyright © 2016 the American Physiological Society.
Deep brain stimulation for the treatment of Alzheimer disease and dementias.
Laxton, Adrian W; Lozano, Andres M
2013-01-01
To review the use of deep brain stimulation (DBS) for treatment of dementia. A PubMed literature search was conducted to identify all studies that have investigated the use of DBS for treatment of dementia. Three studies examined the use of DBS for dementia. One study involved fornix DBS for Alzheimer disease (AD), and two studies involved DBS of the nucleus basalis of Meynert, one to treat AD and one to treat Parkinson disease dementia. Evidence for the use of DBS to treat dementia is preliminary and limited. Fornix and nucleus basalis of Meynert DBS can influence activity in the pathologic neural circuits that underlie AD and Parkinson disease dementia. Further investigation into the potential clinical effects of DBS for dementia is warranted. Copyright © 2013 Elsevier Inc. All rights reserved.
Deep brain stimulation for Parkinson's disease: recent trends and future direction.
Fukaya, Chikashi; Yamamoto, Takamitsu
2015-01-01
To date, deep brain stimulation (DBS) has already been performed on more than 120,000 patients worldwide and in more than 7,000 patients in Japan. However, fundamental understanding of DBS effects on the pathological neural circuitry remains insufficient. Recent studies have specifically shown the importance of cortico-striato-thalamo-cortical (CSTC) loops, which were identified as functionally and anatomically discrete units. Three main circuits exist in the CSTC loops, namely, the motor, associative, and limbic circuits. From these theoretical backgrounds, it is determined that DBS sometimes influences not only motor functions but also the cognitive and affective functions of Parkinson's disease (PD) patients. The main targets of DBS for PD are subthalamic nucleus (STN) and globus pallidus interna (GPi). Ventralis intermedius (Vim)-DBS was found to be effective in improving tremor. However, Vim-DBS cannot sufficiently improve akinesia and rigidity. Therefore, Vim-DBS is seldom carried out for the treatment of PD. In this article, we review the present state of DBS, mainly STN-DBS and GPi-DBS, for PD. In the first part of the article, appropriate indications and practical effects established in previous studies are discussed. The findings of previous investigations on the complications caused by the surgical procedure and on the adverse events induced by DBS itself are reviewed. In the second part, we discuss target selection (GPi vs. STN) and the effect of DBS on nonmotor symptoms. In the final part, as issues that should be resolved, the suitable timing of surgery, symptoms unresponsive to DBS such as on-period axial symptoms, and the related postoperative programing of stimulation parameters, are discussed.
Jimmerson, Leah C.; Ray, Michelle L.; Bushman, Lane R.; Anderson, Peter L.; Klein, Brandon; Rower, Joseph E.; Zheng, Jia-Hua; Kiser, Jennifer J.
2014-01-01
Ribavirin (RBV) is a nucleoside analog used to treat a variety of DNA and RNA viruses. RBV undergoes intracellular phosphorylation to a mono- (MP), di- (DP), and triphosphate (TP). The phosphorylated forms have been associated with the mechanisms of antiviral effect observed in vitro, but the intracellular pharmacology of the drug has not been well characterized in vivo. A highly sensitive LC-MS/MS method was developed and validated for the determination of intracellular RBV MP, DP, and TP in multiple cell matrix types. For this method, the individual MP, DP, and TP fractions were isolated from lysed intracellular matrix using strong anion exchange solid phase extraction, dephosphorylated to parent RBV, desalted and concentrated and quantified using LC-MS/MS. The method utilized a stable labeled internal standard (RBV-13C5) which facilitated accuracy (% deviation within ±15%) and precision (coefficient of variation of ≤15%). The quantifiable linear range for the assay was 0.50 to 200 pmol/sample. The method was applied to the measurement of RBV MP, DP, and TP in human peripheral blood mononuclear cells (PBMC), red blood cells (RBC), and dried blood spot (DBS) samples obtained from patients taking RBV for the treatment of chronic Hepatitis C virus infection. PMID:25555148
ERIC Educational Resources Information Center
Stewart, Neil; Chater, Nick; Brown, Gordon D. A.
2006-01-01
We present a theory of decision by sampling (DbS) in which, in contrast with traditional models, there are no underlying psychoeconomic scales. Instead, we assume that an attribute's subjective value is constructed from a series of binary, ordinal comparisons to a sample of attribute values drawn from memory and is its rank within the sample. We…
Bilateral adaptive deep brain stimulation is effective in Parkinson's disease.
Little, Simon; Beudel, Martijn; Zrinzo, Ludvic; Foltynie, Thomas; Limousin, Patricia; Hariz, Marwan; Neal, Spencer; Cheeran, Binith; Cagnan, Hayriye; Gratwicke, James; Aziz, Tipu Z; Pogosyan, Alex; Brown, Peter
2016-07-01
Adaptive deep brain stimulation (aDBS) uses feedback from brain signals to guide stimulation. A recent acute trial of unilateral aDBS showed that aDBS can lead to substantial improvements in contralateral hemibody Unified Parkinson's Disease Rating Scale (UPDRS) motor scores and may be superior to conventional continuous DBS in Parkinson's disease (PD). We test whether potential benefits are retained with bilateral aDBS and in the face of concurrent medication. We applied bilateral aDBS in 4 patients with PD undergoing DBS of the subthalamic nucleus. aDBS was delivered bilaterally with independent triggering of stimulation according to the amplitude of β activity at the corresponding electrode. Mean stimulation voltage was 3.0±0.1 volts. Motor assessments consisted of double-blinded video-taped motor UPDRS scores that included both limb and axial features. UPDRS scores were 43% (p=0.04; Cohen's d=1.62) better with aDBS than without stimulation. Motor improvement with aDBS occurred despite an average time on stimulation (ToS) of only 45%. Levodopa was well tolerated during aDBS and led to further reductions in ToS. Bilateral aDBS can improve both axial and limb symptoms and can track the need for stimulation across drug states. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Gill, Emily L; Marks, Megan; Yost, Richard A; Vedam-Mai, Vinata; Garrett, Timothy J
2017-12-19
Liquid-microjunction surface sampling (LMJ-SS) is an ambient ionization technique based on the continuous flow of solvent using an in situ microextraction device in which solvent moves through the probe, drawing in the analytes in preparation for ionization using an electrospray ionization source. However, unlike traditional mass spectrometry (MS) techniques, it operates under ambient pressure and requires no sample preparation, thereby making it ideal for rapid sampling of thicker tissue sections for electrophysiological and other neuroscientific research studies. Studies interrogating neural synapses, or a specific neural circuit, typically employ thick, ex vivo tissue sections maintained under near-physiological conditions to preserve tissue viability and maintain the neural networks. Deep brain stimulation (DBS) is a surgical procedure used to treat the neurological symptoms that are associated with certain neurodegenerative and neuropsychiatric diseases. Parkinson's disease (PD) is a neurological disorder which is commonly treated with DBS therapy. PD is characterized by the degeneration of dopaminergic neurons in the substantia nigra pars compacta portion of the brain. Here, we demonstrate that the LMJ-SS methodology can provide a platform for ex vivo analysis of the brain during electrical stimulation, such as DBS. We employ LMJ-SS in the ex vivo analysis of mouse brain tissue for monitoring dopamine during electrical stimulation of the striatum region. The mouse brain tissue was sectioned fresh post sacrifice and maintained in artificial cerebrospinal fluid to create near-physiological conditions before direct sampling using LMJ-SS. A selection of metabolites, including time-sensitive metabolites involved in energy regulation in the brain, were identified using standards, and the mass spectral database mzCloud was used to assess the feasibility of the methodology. Thereafter, the intensity of m/z 154 corresponding to protonated dopamine was monitored before and after electrical stimulation of the striatum region, showing an increase in signal directly following a stimulation event. Dopamine is the key neurotransmitter implicated in PD, and although electrochemical detectors have shown such increases in dopamine post-DBS, this is the first study to do so using MS methodologies.
Camalier, Corrie R; McHugo, Maureen; Zald, David H; Neimat, Joseph S
2018-01-01
In addition to motor symptoms, Parkinson's disease (PD) involves significant non-motor sequelae, including disruptions in cognitive and emotional processing. Fear recognition appears to be affected both by the course of the disease and by a common interventional therapy, deep brain stimulation of the subthalamic nucleus (STN-DBS). Here, we examined if these effects extend to other aspects of emotional processing, such as attentional capture by negative emotional stimuli. Performance on an emotional attentional blink (EAB) paradigm, a common paradigm used to study emotional capture of attention, was examined in a cohort of individuals with PD, both on and off STN-DBS therapy (n=20). To contrast effects of healthy aging and other movement disorder and DBS targets, we also examined performance in a healthy elderly (n=20) and young (n=18) sample on the same task, and a sample diagnosed with Essential Tremor (ET) undergoing therapeutic deep brain stimulation of the ventral-intermediate nucleus (VIM-DBS, n=18). All four groups showed a robust attentional capture of emotional stimuli, irrespective of aging processes, movement disorder diagnosis, or stimulation. PD patients on average had overall worse performance, but this decrement in performance was not related to the emotional capture of attention. PD patients exhibited a robust EAB, indicating that the ability of emotion to direct attention remains intact in PD. Congruent with other recent data, these findings suggest that fear recognition deficits in PD may instead reflect a highly specific problem in recognition, rather than a general deficit in emotional processing of fearful stimuli.
Subthalamic nucleus stimulation impairs emotional conflict adaptation in Parkinson's disease.
Irmen, Friederike; Huebl, Julius; Schroll, Henning; Brücke, Christof; Schneider, Gerd-Helge; Hamker, Fred H; Kühn, Andrea A
2017-10-01
The subthalamic nucleus (STN) occupies a strategic position in the motor network, slowing down responses in situations with conflicting perceptual input. Recent evidence suggests a role of the STN in emotion processing through strong connections with emotion recognition structures. As deep brain stimulation (DBS) of the STN in patients with Parkinson's disease (PD) inhibits monitoring of perceptual and value-based conflict, STN DBS may also interfere with emotional conflict processing. To assess a possible interference of STN DBS with emotional conflict processing, we used an emotional Stroop paradigm. Subjects categorized face stimuli according to their emotional expression while ignoring emotionally congruent or incongruent superimposed word labels. Eleven PD patients ON and OFF STN DBS and eleven age-matched healthy subjects conducted the task. We found conflict-induced response slowing in healthy controls and PD patients OFF DBS, but not ON DBS, suggesting STN DBS to decrease adaptation to within-trial conflict. OFF DBS, patients showed more conflict-induced slowing for negative conflict stimuli, which was diminished by STN DBS. Computational modelling of STN influence on conflict adaptation disclosed DBS to interfere via increased baseline activity. © The Author (2017). Published by Oxford University Press.
NASA Astrophysics Data System (ADS)
Zhang, Tianhe C.; Grill, Warren M.
2010-12-01
Deep brain stimulation (DBS) has emerged as an effective treatment for movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can provide insights into these fundamental mechanisms and typically require two steps: calculation of the electrical potentials generated by DBS and, subsequently, determination of the effects of the extracellular potentials on neurons. The objective of this study was to assess the validity of using a point source electrode to approximate the DBS electrode when calculating the thresholds and spatial distribution of activation of a surrounding population of model neurons in response to monopolar DBS. Extracellular potentials in a homogenous isotropic volume conductor were calculated using either a point current source or a geometrically accurate finite element model of the Medtronic DBS 3389 lead. These extracellular potentials were coupled to populations of model axons, and thresholds and spatial distributions were determined for different electrode geometries and axon orientations. Median threshold differences between DBS and point source electrodes for individual axons varied between -20.5% and 9.5% across all orientations, monopolar polarities and electrode geometries utilizing the DBS 3389 electrode. Differences in the percentage of axons activated at a given amplitude by the point source electrode and the DBS electrode were between -9.0% and 12.6% across all monopolar configurations tested. The differences in activation between the DBS and point source electrodes occurred primarily in regions close to conductor-insulator interfaces and around the insulating tip of the DBS electrode. The robustness of the point source approximation in modeling several special cases—tissue anisotropy, a long active electrode and bipolar stimulation—was also examined. Under the conditions considered, the point source was shown to be a valid approximation for predicting excitation of populations of neurons in response to DBS.
Functional MRI during Hippocampal Deep Brain Stimulation in the Healthy Rat Brain.
Van Den Berge, Nathalie; Vanhove, Christian; Descamps, Benedicte; Dauwe, Ine; van Mierlo, Pieter; Vonck, Kristl; Keereman, Vincent; Raedt, Robrecht; Boon, Paul; Van Holen, Roel
2015-01-01
Deep Brain Stimulation (DBS) is a promising treatment for neurological and psychiatric disorders. The mechanism of action and the effects of electrical fields administered to the brain by means of an electrode remain to be elucidated. The effects of DBS have been investigated primarily by electrophysiological and neurochemical studies, which lack the ability to investigate DBS-related responses on a whole-brain scale. Visualization of whole-brain effects of DBS requires functional imaging techniques such as functional Magnetic Resonance Imaging (fMRI), which reflects changes in blood oxygen level dependent (BOLD) responses throughout the entire brain volume. In order to visualize BOLD responses induced by DBS, we have developed an MRI-compatible electrode and an acquisition protocol to perform DBS during BOLD fMRI. In this study, we investigate whether DBS during fMRI is valuable to study local and whole-brain effects of hippocampal DBS and to investigate the changes induced by different stimulation intensities. Seven rats were stereotactically implanted with a custom-made MRI-compatible DBS-electrode in the right hippocampus. High frequency Poisson distributed stimulation was applied using a block-design paradigm. Data were processed by means of Independent Component Analysis. Clusters were considered significant when p-values were <0.05 after correction for multiple comparisons. Our data indicate that real-time hippocampal DBS evokes a bilateral BOLD response in hippocampal and other mesolimbic structures, depending on the applied stimulation intensity. We conclude that simultaneous DBS and fMRI can be used to detect local and whole-brain responses to circuit activation with different stimulation intensities, making this technique potentially powerful for exploration of cerebral changes in response to DBS for both preclinical and clinical DBS.
Functional MRI during Hippocampal Deep Brain Stimulation in the Healthy Rat Brain
Van Den Berge, Nathalie; Vanhove, Christian; Descamps, Benedicte; Dauwe, Ine; van Mierlo, Pieter; Vonck, Kristl; Keereman, Vincent; Raedt, Robrecht; Boon, Paul; Van Holen, Roel
2015-01-01
Deep Brain Stimulation (DBS) is a promising treatment for neurological and psychiatric disorders. The mechanism of action and the effects of electrical fields administered to the brain by means of an electrode remain to be elucidated. The effects of DBS have been investigated primarily by electrophysiological and neurochemical studies, which lack the ability to investigate DBS-related responses on a whole-brain scale. Visualization of whole-brain effects of DBS requires functional imaging techniques such as functional Magnetic Resonance Imaging (fMRI), which reflects changes in blood oxygen level dependent (BOLD) responses throughout the entire brain volume. In order to visualize BOLD responses induced by DBS, we have developed an MRI-compatible electrode and an acquisition protocol to perform DBS during BOLD fMRI. In this study, we investigate whether DBS during fMRI is valuable to study local and whole-brain effects of hippocampal DBS and to investigate the changes induced by different stimulation intensities. Seven rats were stereotactically implanted with a custom-made MRI-compatible DBS-electrode in the right hippocampus. High frequency Poisson distributed stimulation was applied using a block-design paradigm. Data were processed by means of Independent Component Analysis. Clusters were considered significant when p-values were <0.05 after correction for multiple comparisons. Our data indicate that real-time hippocampal DBS evokes a bilateral BOLD response in hippocampal and other mesolimbic structures, depending on the applied stimulation intensity. We conclude that simultaneous DBS and fMRI can be used to detect local and whole-brain responses to circuit activation with different stimulation intensities, making this technique potentially powerful for exploration of cerebral changes in response to DBS for both preclinical and clinical DBS. PMID:26193653
Zimnik, Andrew J.; Nora, Gerald J.; Desmurget, Michel
2015-01-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN-DBS) has largely replaced ablative therapies for Parkinson's disease. Because of the similar efficacies of the two treatments, it has been proposed that DBS acts by creating an “informational lesion,” whereby pathologic neuronal firing patterns are replaced by low-entropy, stimulus-entrained firing patterns. The informational lesion hypothesis, in its current form, states that DBS blocks the transmission of all information from the basal ganglia, including both pathologic firing patterns and normal, task-related modulations in activity. We tested this prediction in two healthy rhesus macaques by recording single-unit spiking activity from the globus pallidus (232 neurons) while the animals completed choice reaction time reaching movements with and without STN-DBS. Despite strong effects of DBS on the activity of most pallidal cells, reach-related modulations in firing rate were equally prevalent in the DBS-on and DBS-off states. This remained true even when the analysis was restricted to cells affected significantly by DBS. In addition, the overall form and timing of perimovement modulations in firing rate were preserved between DBS-on and DBS-off states in the majority of neurons (66%). Active movement and DBS had largely additive effects on the firing rate of most neurons, indicating an orthogonal relationship in which both inputs contribute independently to the overall firing rate of pallidal neurons. These findings suggest that STN-DBS does not act as an indiscriminate informational lesion but rather as a filter that permits task-related modulations in activity while, presumably, eliminating the pathological firing associated with parkinsonism. PMID:25740526
Square biphasic pulse deep brain stimulation for essential tremor: The BiP tremor study.
De Jesus, Sol; Almeida, Leonardo; Shahgholi, Leili; Martinez-Ramirez, Daniel; Roper, Jaimie; Hass, Chris J; Akbar, Umer; Wagle Shukla, Aparna; Raike, Robert S; Okun, Michael S
2018-01-01
Conventional deep brain stimulation (DBS) utilizes regular, high frequency pulses to treat medication-refractory symptoms in essential tremor (ET). Modifications of DBS pulse shape to achieve improved effectiveness is a promising approach. The current study assessed the safety, tolerability and effectiveness of square biphasic pulse shaping as an alternative to conventional ET DBS. This pilot study compared biphasic pulses (BiP) versus conventional DBS pulses (ClinDBS). Eleven ET subjects with clinically optimized ventralis intermedius nucleus DBS were enrolled. Objective measures were obtained over 3 h while ON BiP stimulation. There was observed benefit in the Fahn-Tolosa Tremor Rating Scale (TRS) for BiP conditions when compared to the DBS off condition and to ClinDBS setting. Total TRS scores during the DBS OFF condition (28.5 IQR = 24.5-35.25) were significantly higher than the other time points. Following active DBS, TRS improved to (20 IQR = 13.8-24.3) at ClinDBS setting and to (16.5 IQR = 12-20.75) at the 3 h period ON BiP stimulation (p = 0.001). Accelerometer recordings revealed improvement in tremor at rest (χ 2 = 16.1, p = 0.006), posture (χ 2 = 15.9, p = 0.007) and with action (χ 2 = 32.1, p=<0.001) when comparing median total scores at ClinDBS and OFF DBS conditions to 3 h ON BiP stimulation. There were no adverse effects and gait was not impacted. BiP was safe, tolerable and effective on the tremor symptoms when tested up to 3 h. This study demonstrated the feasibility of applying a novel DBS waveform in the clinic setting. Larger prospective studies with longer clinical follow-up will be required. Copyright © 2017. Published by Elsevier Ltd.
Madjd, Ameneh; Taylor, Moira A; Delavari, Alireza; Malekzadeh, Reza; Macdonald, Ian A; Farshchi, Hamid R
2017-01-01
To compare the effect of replacing diet beverages (DBs) with water or continuing to drink DBs in patients with type 2 diabetes during a 24-week weight loss program. The primary endpoint was the effect of intervention on weight over a 24-week period. The main secondary endpoints included anthropometric measurement and glucose and fat metabolism during the 24-week period. A total of 81 overweight and obese women with type 2 diabetes, who usually consumed DBs in their diet, were asked to either substitute water for DBs or continue drinking DBs five times per week after lunch for 24 weeks (DBs group) during a weight loss program. Compared with the DBs group, the water group had a greater decrease in weight (water, -6.40 ± 2.42 kg; DBs, -5.25 ± 1.60 kg; P = .006), in BMI (water, -2.49 ± 0.92 kg/m 2 ; DBs, -2.06 ± 0.62 kg/m 2 ; P = .006), in FPG (water, -1.63 ± 0.54 mmol/L; DBs, -1.29 ± 0.48 mmol/L, P = .005), in fasting insulin (water, -5.71 ± 2.30 m lU/mL; DBs, -4.16 ± 1.74 m lU/mL, P = .011), in HOMA IR (water, -3.20 ± 1.17; DBs, -2.48 ± 0.99, P = 003) and in 2 hour postprandial glucose (water, -1.67 ± 0.62 mmol/L; DBs, -1.35 ± 0.39 mmol/L; P = 0.027) over the 24-week period. However, there was no significant time × group interaction for waist circumference, lipid profiles and HbA1c within both groups over the 24-week period. Replacement of DBs with water after the main meal in obese adult women with type 2 diabetes may lead to more weight reduction during a weight loss program. © 2016 John Wiley & Sons Ltd.
van der Plasse, Geoffrey; Schrama, Regina; van Seters, Sebastiaan P.; Vanderschuren, Louk J. M. J.
2012-01-01
Following the successful application of deep brain stimulation (DBS) in the treatment of Parkinson's disease and promising results in clinical trials for obsessive compulsive disorder and major depression, DBS is currently being tested in small patient-populations with eating disorders and addiction. However, in spite of its potential use in a broad spectrum of disorders, the mechanisms of action of DBS remain largely unclear and optimal neural targets for stimulation in several disorders have yet to be established. Thus, there is a great need to examine site-specific effects of DBS on a behavioural level and to understand how DBS may modulate pathological behaviour. In view of the possible application of DBS in the treatment of disorders characterized by impaired processing of reward and motivation, like addiction and eating disorders, we examined the effect of DBS of the nucleus accumbens (NAcc) on food-directed behavior. Rats were implanted with bilateral stimulation electrodes in one of three anatomically and functionally distinct sub-areas of the NAcc: the core, lateral shell (lShell) and medial shell (mShell). Subsequently, we studied the effects of DBS on food consumption, and the motivational and appetitive properties of food. The data revealed a functional dissociation between the lShell and mShell. DBS of the lShell reduced motivation to respond for sucrose under a progressive ratio schedule of reinforcement, mShell DBS, however, profoundly and selectively increased the intake of chow. DBS of the NAcc core did not alter any form of food-directed behavior studied. DBS of neither structure affected sucrose preference. These data indicate that the intake of chow and the motivation to work for palatable food can independently be modulated by DBS of subregions of the NAcc shell. As such, these findings provide important leads for the possible future application of DBS as a treatment for eating disorders such as anorexia nervosa. PMID:22428054
van der Plasse, Geoffrey; Schrama, Regina; van Seters, Sebastiaan P; Vanderschuren, Louk J M J; Westenberg, Herman G M
2012-01-01
Following the successful application of deep brain stimulation (DBS) in the treatment of Parkinson's disease and promising results in clinical trials for obsessive compulsive disorder and major depression, DBS is currently being tested in small patient-populations with eating disorders and addiction. However, in spite of its potential use in a broad spectrum of disorders, the mechanisms of action of DBS remain largely unclear and optimal neural targets for stimulation in several disorders have yet to be established. Thus, there is a great need to examine site-specific effects of DBS on a behavioural level and to understand how DBS may modulate pathological behaviour. In view of the possible application of DBS in the treatment of disorders characterized by impaired processing of reward and motivation, like addiction and eating disorders, we examined the effect of DBS of the nucleus accumbens (NAcc) on food-directed behavior. Rats were implanted with bilateral stimulation electrodes in one of three anatomically and functionally distinct sub-areas of the NAcc: the core, lateral shell (lShell) and medial shell (mShell). Subsequently, we studied the effects of DBS on food consumption, and the motivational and appetitive properties of food. The data revealed a functional dissociation between the lShell and mShell. DBS of the lShell reduced motivation to respond for sucrose under a progressive ratio schedule of reinforcement, mShell DBS, however, profoundly and selectively increased the intake of chow. DBS of the NAcc core did not alter any form of food-directed behavior studied. DBS of neither structure affected sucrose preference. These data indicate that the intake of chow and the motivation to work for palatable food can independently be modulated by DBS of subregions of the NAcc shell. As such, these findings provide important leads for the possible future application of DBS as a treatment for eating disorders such as anorexia nervosa.
Cognitive functioning in psychiatric disorders following deep brain stimulation.
Bergfeld, Isidoor O; Mantione, Mariska; Hoogendoorn, Mechteld L C; Denys, Damiaan
2013-07-01
Deep brain stimulation (DBS) is routinely used as a treatment for treatment-refractory Parkinson's disease and has recently been proposed for psychiatric disorders such as Tourette syndrome (TS), obsessive-compulsive disorder (OCD) and major depressive disorder (MDD). Although cognitive deterioration has repeatedly been shown in patients with Parkinson's disease following DBS, the impact of DBS on cognitive functioning in psychiatric patients has not yet been reviewed. Reviewing the available literature on cognitive functioning following DBS in psychiatric patients. A systematic literature search in PubMed, EMBASE and Web of Science, last updated in September 2012, found 1470 papers. Abstracts were scrutinized and 26 studies examining cognitive functioning of psychiatric patients following DBS were included on basis of predetermined inclusion criteria. Twenty-six studies reported cognitive functioning of 130 psychiatric patients following DBS (37 TS patients, 56 OCD patients, 28 MDD patients, 6 patients with Alzheimer's disease, and 3 patients with other disorders). None of the studies reported substantial cognitive decline following DBS. On the contrary, 13 studies reported cognitive improvement following DBS. Preliminary results suggest that DBS in psychiatric disorders does not lead to cognitive decline. In selected cases cognitive functioning was improved following DBS. However, cognitive improvement cannot be conclusively attributed to DBS since studies are hampered by serious limitations. We discuss the outcomes in light of these limitations and offer suggestions for future work. Copyright © 2013 Elsevier Inc. All rights reserved.
Holtzheimer, Paul E; Husain, Mustafa M; Lisanby, Sarah H; Taylor, Stephan F; Whitworth, Louis A; McClintock, Shawn; Slavin, Konstantin V; Berman, Joshua; McKhann, Guy M; Patil, Parag G; Rittberg, Barry R; Abosch, Aviva; Pandurangi, Ananda K; Holloway, Kathryn L; Lam, Raymond W; Honey, Christopher R; Neimat, Joseph S; Henderson, Jaimie M; DeBattista, Charles; Rothschild, Anthony J; Pilitsis, Julie G; Espinoza, Randall T; Petrides, Georgios; Mogilner, Alon Y; Matthews, Keith; Peichel, DeLea; Gross, Robert E; Hamani, Clement; Lozano, Andres M; Mayberg, Helen S
2017-11-01
Deep brain stimulation (DBS) of the subcallosal cingulate white matter has shown promise as an intervention for patients with chronic, unremitting depression. To test the safety and efficacy of DBS for treatment-resistant depression, a prospective, randomised, sham-controlled trial was conducted. Participants with treatment-resistant depression were implanted with a DBS system targeting bilateral subcallosal cingulate white matter and randomised to 6 months of active or sham DBS, followed by 6 months of open-label subcallosal cingulate DBS. Randomisation was computer generated with a block size of three at each site before the site started the study. The primary outcome was frequency of response (defined as a 40% or greater reduction in depression severity from baseline) averaged over months 4-6 of the double-blind phase. A futility analysis was performed when approximately half of the proposed sample received DBS implantation and completed the double-blind phase. At the conclusion of the 12-month study, a subset of patients were followed up for up to 24 months. The study is registered at ClinicalTrials.gov, number NCT00617162. Before the futility analysis, 90 participants were randomly assigned to active (n=60) or sham (n=30) stimulation between April 10, 2008, and Nov 21, 2012. Both groups showed improvement, but there was no statistically significant difference in response during the double-blind, sham-controlled phase (12 [20%] patients in the stimulation group vs five [17%] patients in the control group). 28 patients experienced 40 serious adverse events; eight of these (in seven patients) were deemed to be related to the study device or surgery. This study confirmed the safety and feasibility of subcallosal cingulate DBS as a treatment for treatment-resistant depression but did not show statistically significant antidepressant efficacy in a 6-month double-blind, sham-controlled trial. Future studies are needed to investigate factors such as clinical features or electrode placement that might improve efficacy. Abbott (previously St Jude Medical). Copyright © 2017 Elsevier Ltd. All rights reserved.
McConnell, George C; So, Rosa Q; Hilliard, Justin D; Lopomo, Paola; Grill, Warren M
2012-11-07
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for the motor symptoms of Parkinson's disease (PD). The effects of DBS depend strongly on stimulation frequency: high frequencies (>90 Hz) improve motor symptoms, while low frequencies (<50 Hz) are either ineffective or exacerbate symptoms. The neuronal basis for these frequency-dependent effects of DBS is unclear. The effects of different frequencies of STN-DBS on behavior and single-unit neuronal activity in the basal ganglia were studied in the unilateral 6-hydroxydopamine lesioned rat model of PD. Only high-frequency DBS reversed motor symptoms, and the effectiveness of DBS depended strongly on stimulation frequency in a manner reminiscent of its clinical effects in persons with PD. Quantification of single-unit activity in the globus pallidus externa (GPe) and substantia nigra reticulata (SNr) revealed that high-frequency DBS, but not low-frequency DBS, reduced pathological low-frequency oscillations (∼9 Hz) and entrained neurons to fire at the stimulation frequency. Similarly, the coherence between simultaneously recorded pairs of neurons within and across GPe and SNr shifted from the pathological low-frequency band to the stimulation frequency during high-frequency DBS, but not during low-frequency DBS. The changes in firing patterns in basal ganglia neurons were not correlated with changes in firing rate. These results indicate that high-frequency DBS is more effective than low-frequency DBS, not as a result of changes in firing rate, but rather due to its ability to replace pathological low-frequency network oscillations with a regularized pattern of neuronal firing.
McConnell, George C.; So, Rosa Q.; Hilliard, Justin D; Lopomo, Paola; Grill, Warren M.
2012-01-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective treatment for the motor symptoms of Parkinson’s disease (PD). The effects of DBS depend strongly on stimulation frequency: high frequencies (>90Hz) improve motor symptoms, while low frequencies (<50Hz) are either ineffective or exacerbate symptoms. The neuronal basis for these frequency-dependent effects of DBS is unclear. The effects of different frequencies of STN-DBS on behavior and single-unit neuronal activity in the basal ganglia were studied in the unilateral 6-hydroxydopamine lesioned rat model of PD. Only high frequency DBS reversed motor symptoms and the effectiveness of DBS depended strongly on stimulation frequency in a manner reminiscent of its clinical effects in persons with PD. Quantification of single-unit activity in the globus pallidus externa (GPe) and substantia nigra reticulata (SNr) revealed that high frequency DBS, but not low frequency DBS, reduced pathological low frequency oscillations (~9Hz) and entrained neurons to fire at the stimulation frequency. Similarly, the coherence between simultaneously recorded pairs of neurons within and across GPe and SNr shifted from the pathological low frequency band to the stimulation frequency during high frequency DBS, but not during low frequency DBS. The changes in firing patterns in basal ganglia neurons were not correlated with changes in firing rate. These results indicate that high frequency DBS is more effective than low frequency DBS, not as a result of changes in firing rate, but rather due to its ability to replace pathological low frequency network oscillations with a regularized pattern of neuronal firing. PMID:23136407
Wang, Jia-Wei; Zhang, Yu-Qing; Zhang, Xiao-Hua; Wang, Yun-Peng; Li, Ji-Ping; Li, Yong-Jie
2016-01-01
Deep brain stimulation (DBS) of either the subthalamic nucleus (STN) or the globus pallidus interna (GPi) can reduce motor symptoms in patients with Parkinson's disease (PD) and improve their quality of life. However, the effects of STN DBS and GPi DBS on cognitive functions and their psychiatric effects remain controversial. The present meta-analysis was therefore performed to clarify these issues. We searched the PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases. Other sources, including internet-based clinical trial registries and grey literature sources, were also searched. After searching the literature, two investigators independently performed literature screens to assess the quality of the included trials and to extract the data. The outcomes included the effects of STN DBS and GPi DBS on multiple cognitive domains, depression, anxiety, and quality of life. Seven articles related to four randomized controlled trials that included 521 participants were incorporated into the present meta-analysis. Compared with GPi DBS, STN DBS was associated with declines in selected cognitive domains after surgery, including attention, working memory and processing speed, phonemic fluency, learning and memory, and global cognition. However, there were no significant differences in terms of quality of life or psychiatric effects, such as depression and anxiety, between the two groups. A selective decline in frontal-subcortical cognitive functions is observed after STN DBS in comparison with GPi DBS, which should not be ignored in the target selection for DBS treatment in PD patients. In addition, compared to GPi DBS, STN DBS does not affect depression, anxiety, and quality of life.
Ellefsen, Kayla N; da Costa, Jose Luiz; Concheiro, Marta; Anizan, Sebastien; Barnes, Allan J; Pirard, Sandrine; Gorelick, David A; Huestis, Marilyn A
2015-01-01
Background: DBS are an increasingly common clinical matrix. Methods & results: Sensitive and specific methods for DBS and venous blood cocaine and metabolite detection by LC–HRMS and 2D GC–MS, respectively, were validated to examine correlation between concentrations following controlled intravenous cocaine administration. Linear ranges from 1 to 200 µg/l were achieved, with acceptable bias and imprecision. Authentic matched specimens’ (392 DBS, 97 venous blood) cocaine and benzoylecgonine concentrations were qualitatively similar, but DBS had much greater variability (21.4–105.9 %CV) and were lower than in blood. Conclusion: DBS offer advantages for monitoring cocaine intake; however, differences between capillary and venous blood and DBS concentration variability must be addressed. PMID:26327184
Tovoli, Francesco; Napoli, Lucia; Negrini, Giulia; D'Addato, Sergio; Tozzi, Giulia; D'Amico, Jessica; Piscaglia, Fabio; Bolondi, Luigi
2017-05-25
Lysosomal acid lipase (LAL) is a key enzyme in lipid metabolism. Initial reports have suggested a role for a relative acquired LAL deficiency in non-alcoholic fatty liver disease (NAFLD)-however, it is still unclear whether this mechanism is specific for NAFLD. We aimed to determine LAL activity in a cohort of NAFLD subjects and in a control group of hepatitis C virus (HCV)-infected patients, investigating the role of liver cirrhosis. A total of 81 patients with a diagnosis of NAFLD, and 78 matched controls with HCV-related liver disease were enrolled. For each patient, LAL activity was determined on peripheral dried blood spots (DBS) and correlated with clinical and laboratory data. A subgroup analysis among cirrhotic patients was also performed. LAL activity is significantly reduced in NAFLD, compared to that in HCV patients. This finding is particularly evident in the pre-cirrhotic stage of disease. LAL activity is also correlated with platelet and white blood cell count, suggesting an analytic interference of portal-hypertension-induced pancytopenia on DBS-determined LAL activity. NAFLD is characterized by a specific deficit in LAL activity, suggesting a pathogenetic role of LAL. We propose that future studies on this topic should rely on tissue specific analyses, as peripheral blood tests are also influenced by confounding factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, SH.; Ballmann, C.; Quarles, C. A.
2009-03-10
The application of positron annihilation lifetime spectroscopy (PALS) and Doppler broadening spectroscopy (DBS) to the study of animal or human tissue has only recently been reported [G. Liu, et al. phys. stat. sol. (C) 4, Nos. 10, 3912-3915 (2007)]. We have initiated a study of normal brain section and brain section with glioma derived from a rat glioma model. For the rat glioma model, 200,000 C6 cells were implanted in the basal ganglion of adult Sprague Dawley rats. The rats were sacrificed at 21 days after implantation. The brains were harvested, sliced into 2 mm thick coronal sections, and fixedmore » in 4% formalin. PALS lifetime runs were made with the samples soaked in formalin, and there was not significant evaporation of formalin during the runs. The lifetime spectra were analyzed into two lifetime components. While early results suggested a small decrease in ortho-Positronium (o-Ps) pickoff lifetime between the normal brain section and brain section with glioma, further runs with additional samples have showed no statistically significant difference between the normal and tumor tissue for this type of tumor. The o-Ps lifetime in formalin alone was lower than either the normal tissue or glioma sample. So annihilation in the formalin absorbed in the samples would lower the o-Ps lifetime and this may have masked any difference due to the glioma itself. DBS was also used to investigate the difference in positronium formation between tumor and normal tissue. Tissue samples are heterogeneous and this needs to be carefully considered if PALS and DBS are to become useful tools in distinguishing tissue samples.« less
Deep Brain Stimulation, Continuity over Time, and the True Self.
Nyholm, Sven; O'Neill, Elizabeth
2016-10-01
One of the topics that often comes up in ethical discussions of deep brain stimulation (DBS) is the question of what impact DBS has, or might have, on the patient's self. This is often understood as a question of whether DBS poses a threat to personal identity, which is typically understood as having to do with psychological and/or narrative continuity over time. In this article, we argue that the discussion of whether DBS is a threat to continuity over time is too narrow. There are other questions concerning DBS and the self that are overlooked in discussions exclusively focusing on psychological and/or narrative continuity. For example, it is also important to investigate whether DBS might sometimes have a positive (e.g., a rehabilitating) effect on the patient's self. To widen the discussion of DBS, so as to make it encompass a broader range of considerations that bear on DBS's impact on the self, we identify six features of the commonly used concept of a person's "true self." We apply these six features to the relation between DBS and the self. And we end with a brief discussion of the role DBS might play in treating otherwise treatment-refractory anorexia nervosa. This further highlights the importance of discussing both continuity over time and the notion of the true self.
Sperens, Maria; Hamberg, Katarina; Hariz, Gun-Marie
2017-01-01
Objective . To explore, in female and male patients with medically treated, moderately advanced Parkinson's disease (PD), their knowledge and reasoning about Deep Brain Stimulation (DBS). Methods . 23 patients with PD (10 women), aged 46-70, were interviewed at a mean of 8 years after diagnosis, with open-ended questions concerning their reflections and considerations about DBS. The interviews were transcribed verbatim and analysed according to the difference and similarity technique in Grounded Theory. Results . From the patients' narratives, the core category "Processing DBS: balancing symptoms, fears and hopes" was established. The patients were knowledgeable about DBS and expressed cautious and well considered attitudes towards its outcome but did not consider themselves ill enough to undergo DBS. They were aware of its potential side-effects. They considered DBS as the last option when oral medication is no longer sufficient. There was no difference between men and women in their reasoning and attitudes towards DBS. Conclusion . This study suggests that knowledge about the pros and cons of DBS exists among PD patients and that they have a cautious attitude towards DBS. Our patients did not seem to endorse an earlier implementation of DBS, and they considered that it should be the last resort when really needed.
2017-01-01
Objective. To explore, in female and male patients with medically treated, moderately advanced Parkinson's disease (PD), their knowledge and reasoning about Deep Brain Stimulation (DBS). Methods. 23 patients with PD (10 women), aged 46–70, were interviewed at a mean of 8 years after diagnosis, with open-ended questions concerning their reflections and considerations about DBS. The interviews were transcribed verbatim and analysed according to the difference and similarity technique in Grounded Theory. Results. From the patients' narratives, the core category “Processing DBS: balancing symptoms, fears and hopes” was established. The patients were knowledgeable about DBS and expressed cautious and well considered attitudes towards its outcome but did not consider themselves ill enough to undergo DBS. They were aware of its potential side-effects. They considered DBS as the last option when oral medication is no longer sufficient. There was no difference between men and women in their reasoning and attitudes towards DBS. Conclusion. This study suggests that knowledge about the pros and cons of DBS exists among PD patients and that they have a cautious attitude towards DBS. Our patients did not seem to endorse an earlier implementation of DBS, and they considered that it should be the last resort when really needed. PMID:28458943
Astroglial Control of the Antidepressant-Like Effects of Prefrontal Cortex Deep Brain Stimulation.
Etiévant, A; Oosterhof, C; Bétry, C; Abrial, E; Novo-Perez, M; Rovera, R; Scarna, H; Devader, C; Mazella, J; Wegener, G; Sánchez, C; Dkhissi-Benyahya, O; Gronfier, C; Coizet, V; Beaulieu, J M; Blier, P; Lucas, G; Haddjeri, N
2015-08-01
Although deep brain stimulation (DBS) shows promising efficacy as a therapy for intractable depression, the neurobiological bases underlying its therapeutic action remain largely unknown. The present study was aimed at characterizing the effects of infralimbic prefrontal cortex (IL-PFC) DBS on several pre-clinical markers of the antidepressant-like response and at investigating putative non-neuronal mechanism underlying DBS action. We found that DBS induced an antidepressant-like response that was prevented by IL-PFC neuronal lesion and by adenosine A1 receptor antagonists including caffeine. Moreover, high frequency DBS induced a rapid increase of hippocampal mitosis and reversed the effects of stress on hippocampal synaptic metaplasticity. In addition, DBS increased spontaneous IL-PFC low-frequency oscillations and both raphe 5-HT firing activity and synaptogenesis. Unambiguously, a local glial lesion counteracted all these neurobiological effects of DBS. Further in vivo electrophysiological results revealed that this astrocytic modulation of DBS involved adenosine A1 receptors and K(+) buffering system. Finally, a glial lesion within the site of stimulation failed to counteract the beneficial effects of low frequency (30 Hz) DBS. It is proposed that an unaltered neuronal-glial system constitutes a major prerequisite to optimize antidepressant DBS efficacy. It is also suggested that decreasing frequency could heighten antidepressant response of partial responders.
LCMV beamforming for a novel wireless local positioning system: a stationarity analysis
NASA Astrophysics Data System (ADS)
Tong, Hui; Zekavat, Seyed A.
2005-05-01
In this paper, we discuss the implementation of Linear Constrained Minimum Variance (LCMV) beamforming (BF) for a novel Wireless Local Position System (WLPS). WLPS main components are: (a) a dynamic base station (DBS), and (b) a transponder (TRX), both mounted on mobiles. WLPS might be considered as a node in a Mobile Adhoc NETwork (MANET). Each TRX is assigned an identification (ID) code. DBS transmits periodic short bursts of energy which contains an ID request (IDR) signal. The TRX transmits back its ID code (a signal with a limited duration) to the DBS as soon as it detects the IDR signal. Hence, the DBS receives non-continuous signals transmitted by TRX. In this work, we assume asynchronous Direct-Sequence Code Division Multiple Access (DS-CDMA) transmission from the TRX with antenna array/LCMV BF mounted at the DBS, and we discuss the implementation of the observed signal covariance matrix for LCMV BF. In LCMV BF, the observed covariance matrix should be estimated. Usually sample covariance matrix (SCM) is used to estimate this covariance matrix assuming a stationary model for the observed data which is the case in many communication systems. However, due to the non-stationary behavior of the received signal in WLPS systems, SCM does not lead to a high WLPS performance compared to even a conventional beamformer. A modified covariance matrix estimation method which utilizes the cyclostationarity property of WLPS system is introduced as a solution to this problem. It is shown that this method leads to a significant improvement in the WLPS performance.
Martínez-Rivera, Freddyson J; Rodriguez-Romaguera, Jose; Lloret-Torres, Mario E; Do Monte, Fabricio H; Quirk, Gregory J; Barreto-Estrada, Jennifer L
2016-11-01
Recent research in humans and rodents has explored the use of deep brain stimulation (DBS) of the ventral capsule/ventral striatum (VS) as a possible treatment for drug addiction. However, the optimum electrode placement and optimum DBS parameters have not been thoroughly studied. Here we varied stimulation sites and frequencies to determine whether DBS of the VS could facilitate the extinction of morphine-induced conditioned place preference in rats. Rats were implanted with DBS electrodes in the dorsal or ventral subregions of the VS and trained to the morphine conditioned place preference. Subsequently, rats received extinction sessions over 9 days, combined with 60 min of either high- (130 Hz) or low- (20 Hz) frequency DBS. To study circuit-wide activations after DBS of the VS, c-fos immunohistochemistry was performed in regions involved in the extinction of drug-seeking behaviors. High-frequency DBS of the dorsal-VS impaired both extinction training and extinction memory, whereas high-frequency DBS of the ventral-VS had no effect. In contrast, low-frequency DBS of the dorsal-VS strengthened extinction memory when tested 2 or 9 days after the cessation of stimulation. Both DBS frequencies increased c-fos expression in the infralimbic prefrontal cortex, but only low-frequency DBS increased c-fos expression in the basal amygdala and the medial portion of the central amygdala. Our results suggest that low-frequency (rather than high-frequency) DBS of the dorsal-VS strengthens extinction memory and may be a potential adjunct for extinction-based therapies for treatment-refractory opioid addiction. Copyright © 2016 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Moving Forward: Advances in the Treatment of Movement Disorders with Deep Brain Stimulation
Schiefer, Terry K.; Matsumoto, Joseph Y.; Lee, Kendall H.
2011-01-01
The modern era of stereotactic and functional neurosurgery has ushered in state of the art technologies for the treatment of movement disorders, particularly Parkinson’s disease (PD), tremor, and dystonia. After years of experience with various surgical therapies, the eventual shortcomings of both medical and surgical treatments, and several serendipitous discoveries, deep brain stimulation (DBS) has risen to the forefront as a highly effective, safe, and reversible treatment for these conditions. Idiopathic advanced PD can be treated with thalamic, globus pallidus internus (GPi), or subthalamic nucleus (STN) DBS. Thalamic DBS primarily relieves tremor while GPi and STN DBS alleviate a wide range of Parkinsonian symptoms. Thalamic DBS is also used in the treatment of other types of tremor, particularly essential tremor, with excellent results. Both primary and various types of secondary dystonia can be treated very effectively with GPi DBS. The variety of anatomical targets for these movement disorders is indicative of the network-level dysfunction mediating these movement disturbances. Despite an increasing understanding of the clinical benefits of DBS, little is known about how DBS can create such wide sweeping neuromodulatory effects. The key to improving this therapeutic modality and discovering new ways to treat these and other neurologic conditions lies in better understanding the intricacies of DBS. Here we review the history and pertinent clinical data for DBS treatment of PD, tremor, and dystonia. While multiple regions of the brain have been targeted for DBS in the treatment of these movement disorders, this review article focuses on those that are most commonly used in current clinical practice. Our search criteria for PubMed included combinations of the following terms: DBS, neuromodulation, movement disorders, PD, tremor, dystonia, and history. Dates were not restricted. PMID:22084629
Creed, Meaghan C; Hamani, Clement; Nobrega, José N
2013-07-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) or internal globus pallidus (GPi) has been routinely used for the treatment of some movement disorders. However, DBS may be associated with adverse psychiatric effects, such as depression, anxiety and impulsivity. To compare DBS applied to the entopeduncular nucleus (EPN; the rodent homolog of the GPi) and STN in terms of their effects on depressive- and anxiety-like behavior in rats. DBS was applied for 21 days (4 h a day) to either the STN or EPN. Rats then underwent behavioral testing on learned helplessness and elevated plus maze tasks before being sacrificed for brain analyses of zif268, BDNF and trkB mRNA as well as BDNF protein levels. Repeated DBS of the STN, but not of the EPN, led to impaired performance in the learned helplessness task, suggesting that STN-DBS induces or potentiates depressive-like behavior. There was no effect of DBS on elevated plus maze or on open field behavior. Repeated STN-DBS, but not EPN-DBS, led to decreased levels of BDNF and trkB mRNA in hippocampus. Acute stimulation of the STN or EPN resulted in similar changes in zif268 levels in several brain areas, except for the raphe where decreases were seen only after STB-DBS. Together these results indicate that the effects of STN- and EPN-DBS differ in behavioral and neurochemical respects. Results further suggest that the EPN may be a preferable target for clinical DBS when psychiatric side effects are considered insofar as it may be associated with a lower incidence of depressive-like behavior than the STN. Copyright © 2013 Elsevier Inc. All rights reserved.
So, Rosa Q; McConnell, George C; Grill, Warren M
2017-03-01
Methamphetamine-induced circling is used to quantify the behavioral effects of subthalamic nucleus (STN) deep brain stimulation (DBS) in hemiparkinsonian rats. We observed a frequency-dependent transient effect of DBS on circling, and quantified this effect to determine its neuronal basis. High frequency STN DBS (75-260Hz) resulted in transient circling contralateral to the lesion at the onset of stimulation, which was not sustained after the first several seconds of stimulation. Following the transient behavioral change, DBS resulted in a frequency-dependent steady-state reduction in pathological ipsilateral circling, but no change in overall movement. Recordings from single neurons in globus pallidus externa (GPe) and substantia nigra pars reticulata (SNr) revealed that high frequency, but not low frequency, STN DBS elicited transient changes in both firing rate and neuronal oscillatory power at the stimulation frequency in a subpopulation of GPe and SNr neurons. These transient changes were not sustained, and most neurons exhibited a different response during the steady-state phase of DBS. During the steady-state, DBS produced elevated neuronal oscillatory power at the stimulus frequency in a majority of GPe and SNr neurons, and the increase was more pronounced during high frequency DBS than during low frequency DBS. Changes in oscillatory power during both transient and steady-state DBS were highly correlated with changes in firing rates. These results suggest that distinct neural mechanisms were responsible for transient and sustained behavioral responses to STN DBS. The transient contralateral turning behavior following the onset of high frequency DBS was paralleled by transient changes in firing rate and oscillatory power in the GPe and SNr, while steady-state suppression of ipsilateral turning was paralleled by sustained increased synchronization of basal ganglia neurons to the stimulus pulses. Our analysis of distinct frequency-dependent transient and steady-state responses to DBS lays the foundation for future mechanistic studies of the immediate and persistent effects of DBS. Copyright © 2016 Elsevier B.V. All rights reserved.
Halfon, Philippe; Ouzan, Denis; Khiri, Hacène; Pénaranda, Guillaume; Castellani, Paul; Oulès, Valerie; Kahloun, Asma; Amrani, Nolwenn; Fanteria, Lise; Martineau, Agnès; Naldi, Lou; Bourlière, Marc
2012-01-01
Background & Aims Point mutations in the coding region of the interleukin 28 gene (rs12979860) have recently been identified for predicting the outcome of treatment of hepatitis C virus infection. This polymorphism detection was based on whole blood DNA extraction. Alternatively, DNA for genetic diagnosis has been derived from buccal epithelial cells (BEC), dried blood spots (DBS), and genomic DNA from serum. The aim of the study was to investigate the reliability and accuracy of alternative routes of testing for single nucleotide polymorphism allele rs12979860CC. Methods Blood, plasma, and sera samples from 200 patients were extracted (400 µL). Buccal smears were tested using an FTA card. To simulate postal delay, we tested the influence of storage at ambient temperature on the different sources of DNA at five time points (baseline, 48 h, 6 days, 9 days, and 12 days) Results There was 100% concordance between blood, plasma, sera, and BEC, validating the use of DNA extracted from BEC collected on cytology brushes for genetic testing. Genetic variations in HPTR1 gene were detected using smear technique in blood smear (3620 copies) as well as in buccal smears (5870 copies). These results are similar to those for whole blood diluted at 1/10. A minimum of 0.04 µL, 4 µL, and 40 µL was necessary to obtain exploitable results respectively for whole blood, sera, and plasma. No significant variation between each time point was observed for the different sources of DNA. IL28B SNPs analysis at these different time points showed the same results using the four sources of DNA. Conclusion We demonstrated that genomic DNA extraction from buccal cells, small amounts of serum, and dried blood spots is an alternative to DNA extracted from peripheral blood cells and is helpful in retrospective and prospective studies for multiple genetic markers, specifically in hard-to-reach individuals. PMID:22412970
PyDBS: an automated image processing workflow for deep brain stimulation surgery.
D'Albis, Tiziano; Haegelen, Claire; Essert, Caroline; Fernández-Vidal, Sara; Lalys, Florent; Jannin, Pierre
2015-02-01
Deep brain stimulation (DBS) is a surgical procedure for treating motor-related neurological disorders. DBS clinical efficacy hinges on precise surgical planning and accurate electrode placement, which in turn call upon several image processing and visualization tasks, such as image registration, image segmentation, image fusion, and 3D visualization. These tasks are often performed by a heterogeneous set of software tools, which adopt differing formats and geometrical conventions and require patient-specific parameterization or interactive tuning. To overcome these issues, we introduce in this article PyDBS, a fully integrated and automated image processing workflow for DBS surgery. PyDBS consists of three image processing pipelines and three visualization modules assisting clinicians through the entire DBS surgical workflow, from the preoperative planning of electrode trajectories to the postoperative assessment of electrode placement. The system's robustness, speed, and accuracy were assessed by means of a retrospective validation, based on 92 clinical cases. The complete PyDBS workflow achieved satisfactory results in 92 % of tested cases, with a median processing time of 28 min per patient. The results obtained are compatible with the adoption of PyDBS in clinical practice.
Gibson, William S; Cho, Shinho; Abulseoud, Osama A; Gorny, Krzysztof R; Felmlee, Joel P; Welker, Kirk M; Klassen, Bryan T; Min, Hoon-Ki; Lee, Kendall H
2017-01-01
Abstract Deep brain stimulation (DBS) of the ventral capsule/ventral striatum (VC/VS) is an investigational therapy for treatment-resistant obsessive-compulsive disorder. The ability of VC/VS DBS to evoke spontaneous mirth in patients, often accompanied by smiling and laughter, is clinically well documented. However, the neural correlates of DBS-evoked mirth remain poorly characterized. Patients undergoing VC/VS DBS surgery underwent intraoperative evaluation in which mirth-inducing and non-mirth-inducing stimulation localizations were identified. Using dynamic causal modeling (DCM) for fMRI, the effect of mirth-inducing DBS on functional and effective connectivity among established nodes in limbic cortico-striato-thalamo-cortical (CSTC) circuitry was investigated. Both mirth-inducing and non-mirth-inducing VC/VS DBS consistently resulted (conjunction, global null, family-wise error-corrected P < 0.05) in activation of amygdala, ventral striatum, and mediodorsal thalamus. However, only mirth-inducing DBS resulted in functional inhibition of anterior cingulate cortex. Dynamic causal modeling revealed that mirth-inducing DBS enhanced effective connectivity from anterior cingulate to ventral striatum, while attenuating connectivity from thalamus to ventral striatum relative to non-mirth-inducing stimulation. These results suggest that DBS-evoked mood elevation is accompanied by distinct patterns of limbic thalamocortical connectivity. Using the novel combination of DBS-evoked mood alteration and functional MRI in human subjects, we provide new insights into the network-level mechanisms that influence affect. PMID:27001680
NASA Astrophysics Data System (ADS)
Niittymäki, Minna; Lahti, Kari; Suhonen, Tomi; Metsäjoki, Jarkko
2015-02-01
Dielectric properties (e.g., DC resistivity and dielectric breakdown strength) of insulating thermally sprayed ceramic coatings differ depending on the form of electrical stress, ambient conditions, and aging of the coating, however, the test arrangements may also have a remarkable effect on the properties. In this paper, the breakdown strength of high velocity oxygen fuel-sprayed alumina coating was studied using six different test arrangements at room conditions in order to study the effects of different test and electrode arrangements on the breakdown behavior. In general, it was shown that test arrangements have a considerable influence on the results. Based on the results, the recommended testing method is to use embedded electrodes between the voltage electrode and the coating at least in DC tests to ensure a good contact with the surface. With and without embedded electrodes, the DBS was 31.7 and 41.8 V/µm, respectively. Under AC excitation, a rather good contact with the sample surface is, anyhow, in most cases acquired by a rather high partial discharge activity and no embedded electrodes are necessarily needed (DBS 29.2 V/µm). However, immersion of the sample in oil should strongly be avoided because the oil penetrates quickly into the coating affecting the DBS (81.2 V/µm).
Ganguli, Malika P; Upton, Adrian R M; Kamath, Markad V
2017-01-01
Epilepsy affects ∼ 1% of the global population, and 33% of patients are nonresponsive to medication and must seek alternative treatment options. Alternative options such as surgery and ablation exist but are not appropriate treatment plans for some patients. Neurostimulation methods such as vagal nerve stimulation, responsive neural stimulation, and deep brain stimulation (DBS) are viable alternatives for medically refractory patients. DBS stimulation has been used in the treatment of Parkinson's disease, dystonia, and pain management. For the treatment of epilepsy, DBS has been found to be an effective treatment plan, with promising results of reduced seizure frequency and intensity. In this review, we discuss DBS surgery and equipment, mechanisms of DBS for epilepsy, and efficacy, technological specifications, and suggestions for future research. We also review a historical summary of experiments involving DBS for epilepsy. Our literature review suggests that further studies are warranted for medically refractory epilepsy using DBS.
Deep brain stimulation changes basal ganglia output nuclei firing pattern in the dystonic hamster.
Leblois, Arthur; Reese, René; Labarre, David; Hamann, Melanie; Richter, Angelika; Boraud, Thomas; Meissner, Wassilios G
2010-05-01
Dystonia is a heterogeneous syndrome of movement disorders characterized by involuntary muscle contractions leading to abnormal movements and postures. While medical treatment is often ineffective, deep brain stimulation (DBS) of the internal pallidum improves dystonia. Here, we studied the impact of DBS in the entopeduncular nucleus (EP), the rodent equivalent of the human globus pallidus internus, on basal ganglia output in the dt(sz)-hamster, a well-characterized model of dystonia by extracellular recordings. Previous work has shown that EP-DBS improves dystonic symptoms in dt(sz)-hamsters. We report that EP-DBS changes firing pattern in the EP, most neurons switching to a less regular firing pattern during DBS. In contrast, EP-DBS did not change the average firing rate of EP neurons. EP neurons display multiphasic responses to each stimulation impulse, likely underlying the disruption of their firing rhythm. Finally, neurons in the substantia nigra pars reticulata display similar responses to EP-DBS, supporting the idea that EP-DBS affects basal ganglia output activity through the activation of common afferent fibers. Copyright 2010 Elsevier Inc. All rights reserved.
Short pauses in thalamic deep brain stimulation promote tremor and neuronal bursting.
Swan, Brandon D; Brocker, David T; Hilliard, Justin D; Tatter, Stephen B; Gross, Robert E; Turner, Dennis A; Grill, Warren M
2016-02-01
We conducted intraoperative measurements of tremor during DBS containing short pauses (⩽50 ms) to determine if there is a minimum pause duration that preserves tremor suppression. Nine subjects with ET and thalamic DBS participated during IPG replacement surgery. Patterns of DBS included regular 130 Hz stimulation interrupted by 0, 15, 25 or 50 ms pauses. The same patterns were applied to a model of the thalamic network to quantify effects of pauses on activity of model neurons. All patterns of DBS decreased tremor relative to 'off'. Patterns with pauses generated less tremor reduction than regular high frequency DBS. The model revealed that rhythmic burst-driver inputs to thalamus were masked during DBS, but pauses in stimulation allowed propagation of bursting activity. The mean firing rate of bursting-type model neurons as well as the firing pattern entropy of model neurons were both strongly correlated with tremor power across stimulation conditions. The temporal pattern of stimulation influences the efficacy of thalamic DBS. Pauses in stimulation resulted in decreased tremor suppression indicating that masking of pathological bursting is a mechanism of thalamic DBS for tremor. Pauses in stimulation decreased the efficacy of open-loop DBS for suppression of tremor. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Humphries, Mark D; Gurney, Kevin
2012-07-01
Deep brain stimulation (DBS) is a remarkably successful treatment for the motor symptoms of Parkinson's disease. High-frequency stimulation of the subthalamic nucleus (STN) within the basal ganglia is a main clinical target, but the physiological mechanisms of therapeutic STN DBS at the cellular and network level are unclear. We set out to begin to address the hypothesis that a mixture of responses in the basal ganglia output nuclei, combining regularized firing and inhibition, is a key contributor to the effectiveness of STN DBS. We used our computational model of the complete basal ganglia circuit to show how such a mixture of responses in basal ganglia output naturally arises from the network effects of STN DBS. We replicated the diversification of responses recorded in a primate STN DBS study to show that the model's predicted mixture of responses is consistent with therapeutic STN DBS. We then showed how this 'mixture of response' perspective suggests new ideas for DBS mechanisms: first, that the therapeutic frequency of STN DBS is above 100 Hz because the diversification of responses exhibits a step change above this frequency; and second, that optogenetic models of direct STN stimulation during DBS have proven therapeutically ineffective because they do not replicate the mixture of basal ganglia output responses evoked by electrical DBS. © 2012 The Authors. European Journal of Neuroscience © 2012 Federation of European Neuroscience Societies and Blackwell Publishing Ltd.
Wojtecki, Lars; Storzer, Lena; Schnitzler, Alfons
2016-01-01
Abstract Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a widely used treatment for the motor symptoms of Parkinson’s disease (PD). DBS or pharmacological treatment is believed to modulate the tendency to, or reverse, impulse control disorders. Several brain areas involved in impulsivity and reward valuation, such as the prefrontal cortex and striatum, are linked to the STN, and activity in these areas might be affected by STN-DBS. To investigate the effect of STN-DBS on one type of impulsive decision-making—delay discounting (i.e., the devaluation of reward with increasing delay until its receipt)—we tested 40 human PD patients receiving STN-DBS treatment and medication for at least 3 months. Patients were pseudo-randomly assigned to one of four groups to test the effects of DBS on/off states as well as medication on/off states on delay discounting. The delay-discounting task consisted of a series of choices among a smaller. sooner or a larger, later monetary reward. Despite considerable effects of DBS on motor performance, patients receiving STN-DBS did not choose more or less impulsively compared with those in the off-DBS group, as well as when controlling for risk attitude. Although null results have to be interpreted with caution, our findings are of significance to other researchers studying the effects of PD treatment on impulsive decision-making, and they are of clinical relevance for determining the therapeutic benefits of using STN-DBS. PMID:27257622
Treating post-traumatic tremor with deep brain stimulation: report of five cases.
Issar, Neil M; Hedera, Peter; Phibbs, Fenna T; Konrad, Peter E; Neimat, Joseph S
2013-12-01
Post-traumatic tremor is one of the most common movement disorders resulting from severe head trauma. However, literature regarding successful deep brain stimulation (DBS) treatment is scarce, resulting in ambiguity regarding the optimal lead location. Most cases support the ventral intermediate nucleus, but there is evidence to defend DBS of the zona incerta, ventral oralis anterior/posterior, and/or a combination of these targets. We report five patients with disabling post-traumatic tremor treated with DBS of the ventral intermediate nucleus and of the globus pallidus internus. Patients were referred to the Vanderbilt Movement Disorders Division, and surgical intervention was determined by a DBS Multidisciplinary Committee. Standard DBS procedure was followed. Patients 1-4 sustained severe diffuse axonal injuries. Patients 1-3 underwent unilateral ventral intermediate nucleus DBS for contralateral tremor, while Patient 4 underwent bilateral ventral intermediate nucleus DBS. Patients 1-3 experienced good tremor reduction, while Patient 4 experienced moderate tremor reduction with some dystonic posturing of the hands. Patient 5 had dystonic posturing of the right upper extremity with tremor of the left upper extremity. He was treated with bilateral DBS of the globus pallidus internus and showed good tremor reduction at follow-up. Unilateral or bilateral DBS of the ventral intermediate nucleus and bilateral DBS of the globus pallidus internus may be effective and safe treatment modalities for intractable post-traumatic tremor. Further studies are needed to clarify the optimal target for surgical treatment of post-traumatic tremor. Published by Elsevier Ltd.
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, Simon; Pogosyan, Alex; Neal, Spencer; Zavala, Baltazar; Zrinzo, Ludvic; Hariz, Marwan; Foltynie, Thomas; Limousin, Patricia; Ashkan, Keyoumars; FitzGerald, James; Green, Alexander L; Aziz, Tipu Z; Brown, Peter
2013-09-01
Brain-computer interfaces (BCIs) could potentially be used to interact with pathological brain signals to intervene and ameliorate their effects in disease states. Here, we provide proof-of-principle of this approach by using a BCI to interpret pathological brain activity in patients with advanced Parkinson disease (PD) and to use this feedback to control when therapeutic deep brain stimulation (DBS) is delivered. Our goal was to demonstrate that by personalizing and optimizing stimulation in real time, we could improve on both the efficacy and efficiency of conventional continuous DBS. We tested BCI-controlled adaptive DBS (aDBS) of the subthalamic nucleus in 8 PD patients. Feedback was provided by processing of the local field potentials recorded directly from the stimulation electrodes. The results were compared to no stimulation, conventional continuous stimulation (cDBS), and random intermittent stimulation. Both unblinded and blinded clinical assessments of motor effect were performed using the Unified Parkinson's Disease Rating Scale. Motor scores improved by 66% (unblinded) and 50% (blinded) during aDBS, which were 29% (p = 0.03) and 27% (p = 0.005) better than cDBS, respectively. These improvements were achieved with a 56% reduction in stimulation time compared to cDBS, and a corresponding reduction in energy requirements (p < 0.001). aDBS was also more effective than no stimulation and random intermittent stimulation. BCI-controlled DBS is tractable and can be more efficient and efficacious than conventional continuous neuromodulation for PD. Copyright © 2013 American Neurological Association.
Rejecting deep brain stimulation artefacts from MEG data using ICA and mutual information.
Abbasi, Omid; Hirschmann, Jan; Schmitz, Georg; Schnitzler, Alfons; Butz, Markus
2016-08-01
Recording brain activity during deep brain stimulation (DBS) using magnetoencephalography (MEG) can potentially help clarifying the neurophysiological mechanism of DBS. The DBS artefact, however, distorts MEG data significantly. We present an artefact rejection approach to remove the DBS artefact from MEG data. We developed an approach consisting of four consecutive steps: (i) independent component analysis was used to decompose MEG data to independent components (ICs); (ii) mutual information (MI) between stimulation signal and all ICs was calculated; (iii) artefactual ICs were identified by means of an MI threshold; and (iv) the MEG signal was reconstructed using only non-artefactual ICs. This approach was applied to MEG data from five Parkinson's disease patients with implanted DBS stimulators. MEG was recorded with DBS ON (unilateral stimulation of the subthalamic nucleus) and DBS OFF during two experimental conditions: a visual attention task and alternating right and left median nerve stimulation. With the presented approach most of the artefact could be removed. The signal of interest could be retrieved in both conditions. In contrast to existing artefact rejection methods for MEG-DBS data (tSSS and S(3)P), the proposed method uses the actual artefact source, i.e. the stimulation signal, as reference signal. Using the presented method, the DBS artefact can be significantly rejected and the physiological data can be restored. This will facilitate research addressing the impact of DBS on brain activity during rest and various tasks. Copyright © 2016 Elsevier B.V. All rights reserved.
Gait and Balance in Essential Tremor: Variable Effects of Bilateral Thalamic Stimulation
Earhart, Gammon M.; Clark, B. Ruth; Tabbal, Samer D.; Perlmutter, Joel S.
2010-01-01
Essential tremor (ET) is a multi-faceted condition best known for postural and action tremor but also may include disordered gait and postural instability. Deep brain stimulation (DBS) of the ventral intermediate nucleus (VIM) of the thalamus provides substantial tremor reduction yet some patients with bilateral VIM DBS have gait and balance impairment. This study examines gait and balance performance in 13 participants with ET who have bilateral VIM DBS compared to a matched control group. Participants with ET were tested with their stimulators off (DBS OFF) and on (DBS ON). For both standard and tandem walking, participants with ET walked significantly more slowly than controls, with significantly lower cadence, spending a lower percentage of the gait cycle in single limb support and a higher percentage in double support compared to controls. Participants with ET also had significantly lower tandem and one leg stance times, Berg balance scores, balance confidence, and required significantly greater time to perform the Timed Up-and-Go relative to controls. There were no significant differences in any gait or balance measures in the DBS OFF versus DBS ON conditions, but the effects of DBS on gait and balance were highly variable among individuals. Future studies are needed to determine why some individuals experience gait and balance difficulties after bilateral thalamic DBS and others do not. A better understanding of the mechanisms underlying gait and balance impairments in those with bilateral DBS is critical in order to reduce falls and fractures in this group. PMID:19006189
Artistic creativity and DBS: a case report.
Drago, V; Foster, P S; Okun, M S; Haq, I; Sudhyadhom, A; Skidmore, F M; Heilman, K M
2009-01-15
Deep brain stimulation (DBS) is a treatment for patients with Parkinson's disease (PD) who are not adequately controlled with medications. An artist reported changes in her artistic creativity and art appreciation when treated with left DBS. We sought to study her artistic productions and her appreciation of art while both "on" and "off" left DBS. A 69-year-old right-handed woman with an approximate 20-year history of PD was referred to us for management of a left subthalamic region nucleus (STN) DBS placed at another institution 4 years prior. In Experiment 1 we had her rate several dimensions (Evocative Impact, Aesthetics, Novelty, Technique, Closure and Representation) of another artist's paintings. In Experiment 2, we tested her with the Abbreviated Torrance Test (of creativity) for Adults (ATTA). During testing the patient remained on her dopaminergic medication, but was tested on and off left DBS. On the judgment task while "on" left DBS, versus "off" DBS, there were significant reductions in her appreciation of artistic Closure and Technique. When "off" DBS her ATTA creativity index was above average, but when switched "on" her creativity index was below average. These results suggest the possibility that left ventral STN/SNR DBS reduces creativity as well as appreciation of art. The reason for these alterations is not known, but might be related to enhanced activation of the left hemisphere and reciprocal deactivation of the right hemisphere which mediates both visuospatial skills and global attention, both of which are important in artistic creativity and appreciation.
Effects of deep brain stimulation on rest tremor progression in early stage Parkinson disease.
Hacker, Mallory L; DeLong, Mahlon R; Turchan, Maxim; Heusinkveld, Lauren E; Ostrem, Jill L; Molinari, Anna L; Currie, Amanda D; Konrad, Peter E; Davis, Thomas L; Phibbs, Fenna T; Hedera, Peter; Cannard, Kevin R; Drye, Lea T; Sternberg, Alice L; Shade, David M; Tonascia, James; Charles, David
2018-06-29
To evaluate whether the progression of individual motor features was influenced by early deep brain stimulation (DBS), a post hoc analysis of Unified Parkinson's Disease Rating Scale-III (UPDRS-III) score (after a 7-day washout) was conducted from the 2-year DBS in early Parkinson disease (PD) pilot trial dataset. The prospective pilot trial enrolled patients with PD aged 50-75 years, treated with PD medications for 6 months-4 years, and no history of dyskinesia or other motor fluctuations, who were randomized to receive optimal drug therapy (ODT) or DBS plus ODT (DBS + ODT). At baseline and 6, 12, 18, and 24 months, all patients stopped all PD therapy for 1 week (medication and stimulation, if applicable). UPDRS-III "off" item scores were compared between the ODT and DBS + ODT groups (n = 28); items with significant between-group differences were analyzed further. UPDRS-III "off" rest tremor score change from baseline to 24 months was worse in patients receiving ODT vs DBS + ODT ( p = 0.002). Rest tremor slopes from baseline to 24 months favored DBS + ODT both "off" and "on" therapy ( p < 0.001, p = 0.003, respectively). More ODT patients developed new rest tremor in previously unaffected limbs than those receiving DBS + ODT ( p = 0.001). These results suggest the possibility that DBS in early PD may slow rest tremor progression. Future investigation in a larger cohort is needed, and these findings will be tested in the Food and Drug Administration-approved, phase III, pivotal, multicenter clinical trial evaluating DBS in early PD. This study provides Class II evidence that for patients with early PD, DBS may slow the progression of rest tremor. © 2018 American Academy of Neurology.
Lenartz, Doris; Kuhn, Jens; Sturm, Volker
2016-01-01
Background The current notion that cortico-striato-thalamo-cortical circuits are involved in the pathophysiology of obsessive-compulsive disorder (OCD) has instigated the search for the most suitable target for deep brain stimulation (DBS). However, despite extensive research, uncertainty about the ideal target remains with many structures being underexplored. The aim of this report is to address a new target for DBS, the medial dorsal (MD) and the ventral anterior (VA) nucleus of the thalamus, which has thus far received little attention in the treatment of OCD. Methods In this retrospective trial, four patients (three female, one male) aged 31–48 years, suffering from therapy-refractory OCD underwent high-frequency DBS of the MD and VA. In two patients (de novo group) the thalamus was chosen as a primary target for DBS, whereas in two patients (rescue DBS group) lead implantation was performed in a rescue DBS attempt following unsuccessful primary stimulation. Results Continuous thalamic stimulation yielded no significant improvement in OCD symptom severity. Over the course of thalamic DBS symptoms improved in only one patient who showed “partial response” on the Yale-Brown Obsessive Compulsive (Y-BOCS) Scale. Beck Depression Inventory scores dropped by around 46% in the de novo group; anxiety symptoms improved by up to 34%. In the de novo DBS group no effect of DBS on anxiety and mood was observable. Conclusion MD/VA-DBS yielded no adequate alleviation of therapy-refractory OCD, the overall strategy in targeting MD/VA as described in this paper can thus not be recommended in DBS for OCD. The magnocellular portion of MD (MDMC), however, might prove a promising target in the treatment of mood related and anxiety disorders. PMID:27504631
Subthalamic stimulation may inhibit the beneficial effects of levodopa on akinesia and gait.
Fleury, Vanessa; Pollak, Pierre; Gere, Julien; Tommasi, Giorgio; Romito, Luigi; Combescure, Christophe; Bardinet, Eric; Chabardes, Stephan; Momjian, Shahan; Krainik, Alexandre; Burkhard, Pierre; Yelnik, Jérôme; Krack, Paul
2016-09-01
Gait and akinesia deterioration in PD patients during the immediate postoperative period of DBS has been directly related to stimulation in the subthalamic region. The underlying mechanisms remain poorly understood. The aim of the present study was to clinically and anatomically describe this side effect. PD patients presenting with a worsening of gait and/or akinesia following STN-DBS, that was reversible on stimulation arrest were included. The evaluation included (1) a Stand Walk Sit Test during a monopolar survey of each electrode in the on-drug condition; (2) a 5-condition test with the following conditions: off-drug/off-DBS, off-drug/on-best-compromise-DBS, on-drug/off-DBS, on-drug/on-best-compromise-DBS, and on-drug/on-worsening-DBS, which utilized the contact inducing the most prominent gait deterioration. The following scales were performed: UPDRSIII subscores, Stand Walk Sit Test, and dyskinesia and freezing of gait scales. Localization of contacts was performed using a coregistration method. Twelve of 17 patients underwent the complete evaluation. Stimulation of the most proximal contacts significantly slowed down the Stand Walk Sit Test. The on-drug/on-worsening-DBS condition compared with the on-drug/off-DBS condition worsened akinesia (P = 0.02), Stand Walk Sit Test (P = 0.001), freezing of gait (P = 0.02), and improved dyskinesias (P = 0.003). Compared with the off-drug/off-DBS condition, the on-drug/on-worsening-DBS condition improved rigidity (P = 0.007) and tremor (P = 0.007). Worsening contact sites were predominantly dorsal and anterior to the STN in the anterior zona incerta and Forel fields H2. A paradoxical deterioration of gait and akinesia is a rare side effect following STN-DBS. We propose that this may be related to misplaced contacts, and we discuss the pathophysiology and strategies to identify and manage this complication. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.
Clinical outcomes of asleep vs awake deep brain stimulation for Parkinson disease.
Brodsky, Matthew A; Anderson, Shannon; Murchison, Charles; Seier, Mara; Wilhelm, Jennifer; Vederman, Aaron; Burchiel, Kim J
2017-11-07
To compare motor and nonmotor outcomes at 6 months of asleep deep brain stimulation (DBS) for Parkinson disease (PD) using intraoperative imaging guidance to confirm electrode placement vs awake DBS using microelectrode recording to confirm electrode placement. DBS candidates with PD referred to Oregon Health & Science University underwent asleep DBS with imaging guidance. Six-month outcomes were compared to those of patients who previously underwent awake DBS by the same surgeon and center. Assessments included an "off"-levodopa Unified Parkinson's Disease Rating Scale (UPDRS) II and III, the 39-item Parkinson's Disease Questionnaire, motor diaries, and speech fluency. Thirty participants underwent asleep DBS and 39 underwent awake DBS. No difference was observed in improvement of UPDRS III (+14.8 ± 8.9 vs +17.6 ± 12.3 points, p = 0.19) or UPDRS II (+9.3 ± 2.7 vs +7.4 ± 5.8 points, p = 0.16). Improvement in "on" time without dyskinesia was superior in asleep DBS (+6.4 ± 3.0 h/d vs +1.7 ± 1.2 h/d, p = 0.002). Quality of life scores improved in both groups (+18.8 ± 9.4 in awake, +8.9 ± 11.5 in asleep). Improvement in summary index ( p = 0.004) and subscores for cognition ( p = 0.011) and communication ( p < 0.001) were superior in asleep DBS. Speech outcomes were superior in asleep DBS, both in category (+2.77 ± 4.3 points vs -6.31 ± 9.7 points ( p = 0.0012) and phonemic fluency (+1.0 ± 8.2 points vs -5.5 ± 9.6 points, p = 0.038). Asleep DBS for PD improved motor outcomes over 6 months on par with or better than awake DBS, was superior with regard to speech fluency and quality of life, and should be an option considered for all patients who are candidates for this treatment. NCT01703598. This study provides Class III evidence that for patients with PD undergoing DBS, asleep intraoperative CT imaging-guided implantation is not significantly different from awake microelectrode recording-guided implantation in improving motor outcomes at 6 months. © 2017 American Academy of Neurology.
Quality assurance in the HIV/AIDS laboratory network of China.
Jiang, Yan; Qiu, Maofeng; Zhang, Guiyun; Xing, Wenge; Xiao, Yao; Pan, Pinliang; Yao, Jun; Ou, Chin-Yih; Su, Xueli
2010-12-01
In 2009, there were 8273 local screening laboratories, 254 confirmatory laboratories, 35 provincial confirmatory central laboratories and 1 National AIDS Reference Laboratory (NARL) in China. These laboratories were located in Center for Disease Control and Prevention (CDC) facilities, hospitals, blood donation clinics, maternal and child health (MCH) hospitals and border health quarantine health-care facilities. The NARL and provincial laboratories provide quality assurance through technical, bio-safety and managerial training; periodic proficiency testing; on-site supervisory inspections; and commercial serologic kit evaluations. From 2002 to 2009, more than 220 million HIV antibody tests were performed at screening laboratories, and all reactive and indeterminate samples were confirmed at confirmatory laboratories. The use of highly technically complex tests, including CD4 cell enumeration, viral load, dried blood spot (DBS)-based early infant diagnosis (EID), drug resistance (DR) genotyping, HIV-1 subtyping and incidence assays, have increased in recent years and their performance quality is closely monitored. China has made significant progress in establishing a well-coordinated HIV laboratory network and QA systems. However, the coverage and intensity of HIV testing and quality assurance programmes need to be strengthened so as to ensure that more infected persons are diagnosed and that they receive timely prevention and treatment services.
Hoagland, Brenda; Moreira, Ronaldo I; De Boni, Raquel B; Kallas, Esper G; Madruga, José Valdez; Vasconcelos, Ricardo; Goulart, Silvia; Torres, Thiago S; Marins, Luana M S; Anderson, Peter L; Luz, Paula M; Costa Leite, Iuri da; Liu, Albert Y; Veloso, Valdilea G; Grinsztejn, Beatriz
2017-04-06
The efficacy of pre-exposure prophylaxis (PrEP) in preventing sexual acquisition of human immunodeficiency virus (HIV) is well established. Little is known about the feasibility of PrEP implementation in middle-income settings with concentrated epidemics among men who have sex with men (MSM) and transgender women (TGW). PrEP Brasil is a prospective, multicentre, open-label demonstration project assessing PrEP delivery in the context of the Brazilian Public Health System. HIV-uninfected MSM and TGW in 3 referral centres in Rio de Janeiro and São Paulo were evaluated for eligibility and offered 48 weeks of daily emtricitabine/tenofovir for PrEP. Concentrations of tenofovir diphosphate in dried blood spot samples (DBS) at week 4 after enrolment (early adherence) were measured. Predictors of drug levels were assessed using ordinal logistic regression models considering the DBS drug level as a 3 level variable (<350 fmol/punch, ≥350-699 fmol/punch and ≥700 fmol/punch). 1,270 individuals were assessed for participation; n = 738 were potentially eligible and n = 450 were offered PrEP (PrEP uptake was 60.9%). Eligible but not enrolled individuals were younger, had lower HIV risk perception and had lower PrEP awareness. At week 4, 424 participants (of the 450 enrolled) had DBS TFV-DP concentrations, 94.1% in the protective range (≥350 fmol/punch, consistent with ≥2 pills per week), and 78% were in the highly protective range (≥700 fmol/punch, ≥4 pills per week). Participants with ≥12 years of schooling had 1.9 times the odds (95%CI 1.10-3.29) of a higher versus lower drug level than participants with <12 years of schooling. Condomless receptive anal intercourse in the prior 3 months was also associated with higher drug levels (adjusted OR = 1.78; 95% CI 1.08-2.94). The high uptake and early adherence indicate that PrEP for high-risk MSM and TGW can be successfully delivered in the context of the Brazilian Public Health System. Interventions to address disparities on PrEP awareness and HIV risk perception among the younger and less educated are urgently needed in order to maximize the impact of this prevention strategy on the reduction of HIV infection among MSM and TGW in Brazil.
NASA Astrophysics Data System (ADS)
Mao, Deqing; Zhang, Yin; Zhang, Yongchao; Huang, Yulin; Yang, Jianyu
2018-01-01
Doppler beam sharpening (DBS) is a critical technology for airborne radar ground mapping in forward-squint region. In conventional DBS technology, the narrow-band Doppler filter groups formed by fast Fourier transform (FFT) method suffer from low spectral resolution and high side lobe levels. The iterative adaptive approach (IAA), based on the weighted least squares (WLS), is applied to the DBS imaging applications, forming narrower Doppler filter groups than the FFT with lower side lobe levels. Regrettably, the IAA is iterative, and requires matrix multiplication and inverse operation when forming the covariance matrix, its inverse and traversing the WLS estimate for each sampling point, resulting in a notably high computational complexity for cubic time. We propose a fast IAA (FIAA)-based super-resolution DBS imaging method, taking advantage of the rich matrix structures of the classical narrow-band filtering. First, we formulate the covariance matrix via the FFT instead of the conventional matrix multiplication operation, based on the typical Fourier structure of the steering matrix. Then, by exploiting the Gohberg-Semencul representation, the inverse of the Toeplitz covariance matrix is computed by the celebrated Levinson-Durbin (LD) and Toeplitz-vector algorithm. Finally, the FFT and fast Toeplitz-vector algorithm are further used to traverse the WLS estimates based on the data-dependent trigonometric polynomials. The method uses the Hermitian feature of the echo autocorrelation matrix R to achieve its fast solution and uses the Toeplitz structure of R to realize its fast inversion. The proposed method enjoys a lower computational complexity without performance loss compared with the conventional IAA-based super-resolution DBS imaging method. The results based on simulations and measured data verify the imaging performance and the operational efficiency.
Deep brain stimulation of nucleus accumbens region in alcoholism affects reward processing.
Heldmann, Marcus; Berding, Georg; Voges, Jürgen; Bogerts, Bernhard; Galazky, Imke; Müller, Ulf; Baillot, Gunther; Heinze, Hans-Jochen; Münte, Thomas F
2012-01-01
The influence of bilateral deep brain stimulation (DBS) of the nucleus nucleus (NAcc) on the processing of reward in a gambling paradigm was investigated using H(2)[(15)O]-PET (positron emission tomography) in a 38-year-old man treated for severe alcohol addiction. Behavioral data analysis revealed a less risky, more careful choice behavior under active DBS compared to DBS switched off. PET showed win- and loss-related activations in the paracingulate cortex, temporal poles, precuneus and hippocampus under active DBS, brain areas that have been implicated in action monitoring and behavioral control. Except for the temporal pole these activations were not seen when DBS was deactivated. These findings suggest that DBS of the NAcc may act partially by improving behavioral control.
Investigation of DBS electro-oxidation reaction in the aqueous-organic solution of LiClO4.
Darlewski, Witold; Popiel, Stanisław; Nalepa, Tomasz; Gromotowicz, Waldemar; Szewczyk, Rafał; Stankiewicz, Romuald
2010-03-15
A process of dibutyl sulphide (DBS) electro-oxidation using electrolysis and cyclic voltamperometry was investigated in water-methanol solution using different electrodes (platinum, boron doped diamond, graphite and glassy carbon). Obtained results indicate that the DBS electro-oxidation process is irreversible in voltamperometric conditions. It was shown that during DBS electrolytic oxidation on Pt, at the low anode potential (1.8 V), DBS was oxidized to sulphoxide and sulphone. Electrolysis at higher potential (up to 3.0 V) resulted in complete DBS oxidation and formation of various products, including: butyric acid, sulphuric acid, butanesulphinic acid, butanesulphonic acid, identified using gas chromatography (GC-AED) and mass spectrometry (GC-MS) methods. (c) 2009 Elsevier B.V. All rights reserved.
Demeter, Gyula; Valálik, István; Pajkossy, Péter; Szőllősi, Ágnes; Lukács, Ágnes; Kemény, Ferenc; Racsmány, Mihály
2017-04-24
Although the improvement of motor symptoms in Parkinson's disease (PD) after deep brain stimulation (DBS) of the subthalamic nucleus (STN) is well documented, there are open questions regarding its impact on cognitive functions. The aim of this study was to assess the effect of bilateral DBS of the STN on executive functions in PD patients using a DBS wait-listed PD control group. Ten PD patients with DBS implantation (DBS group) and ten PD wait-listed patients (Clinical control group) participated in the study. Neuropsychological tasks were used to assess general mental ability and various executive functions. Each task was administered twice to each participant: before and after surgery (with the stimulators on) in the DBS group and with a matched delay between the two task administration points in the control group. There was no significant difference between the DBS and the control groups' performance in tasks measuring the updating of verbal, spatial or visual information (Digit span, Corsi and N-back tasks), planning and shifting (Trail Making B), and conflict resolution (Stroop task). However, the DBS group showed a significant decline on the semantic verbal fluency task after surgery compared to the control group, which is in line with findings of previous studies. Our results provide support for the relative cognitive safety of the STN DBS using a wait-listed PD control group. Differential effects of the STN DBS on frontostriatal networks are discussed. Copyright © 2017 Elsevier B.V. All rights reserved.
Surgical Neuroanatomy and Programming in Deep Brain Stimulation for Obsessive Compulsive Disorder
Morishita, Takashi; Fayad, Sarah M.; Goodman, Wayne K.; Foote, Kelly D.; Chen, Dennis; Peace, David A.; Rhoton, Albert L.; Okun, Michael S.
2014-01-01
Objectives Deep brain stimulation (DBS) has been established as a safe, effective therapy for movement disorders (Parkinson’s disease, essential tremor, etc.), and its application is expanding to the treatment of other intractable neuropsychiatric disorders including Depression and Obsessive-Compulsive Disorder (OCD). Several published studies have supported the efficacy of DBS for severely debilitating OCD. However, questions remain regarding the optimal anatomical target and the lack of a bedside programming paradigm for OCD DBS. Management of OCD DBS can be highly variable and is typically guided by each center’s individual expertise. In this paper, we review the various approaches to targeting and programming for OCD DBS. We also review the clinical experience for each proposed target, and discuss the relevant neuroanatomy. Methods A PubMed review was performed searching for literature on OCD DBS and included all articles published before March 2012. We included all available studies with a clear description of the anatomical targets, programming details, and the outcomes. Results Six different DBS approaches were identified. High frequency stimulation with high voltage was applied in most cases, and predictive factors for favorable outcomes were discussed in the literature. Conclusion DBS remains an experimental treatment for medication refractory OCD. Target selection and programming paradigms are not yet standardized, though, an improved understanding of the relationship between the DBS lead and the surrounding neuroanatomical structures will aid in the selection of targets and the approach to programming. We propose to form a registry to track OCD DBS cases for future clinical study design. PMID:24345303
Surgical neuroanatomy and programming in deep brain stimulation for obsessive compulsive disorder.
Morishita, Takashi; Fayad, Sarah M; Goodman, Wayne K; Foote, Kelly D; Chen, Dennis; Peace, David A; Rhoton, Albert L; Okun, Michael S
2014-06-01
Deep brain stimulation (DBS) has been established as a safe, effective therapy for movement disorders (Parkinson's disease, essential tremor, etc.), and its application is expanding to the treatment of other intractable neuropsychiatric disorders including depression and obsessive-compulsive disorder (OCD). Several published studies have supported the efficacy of DBS for severely debilitating OCD. However, questions remain regarding the optimal anatomic target and the lack of a bedside programming paradigm for OCD DBS. Management of OCD DBS can be highly variable and is typically guided by each center's individual expertise. In this paper, we review the various approaches to targeting and programming for OCD DBS. We also review the clinical experience for each proposed target and discuss the relevant neuroanatomy. A PubMed review was performed searching for literature on OCD DBS and included all articles published before March 2012. We included all available studies with a clear description of the anatomic targets, programming details, and the outcomes. Six different DBS approaches were identified. High-frequency stimulation with high voltage was applied in most cases, and predictive factors for favorable outcomes were discussed in the literature. DBS remains an experimental treatment for medication refractory OCD. Target selection and programming paradigms are not yet standardized, though an improved understanding of the relationship between the DBS lead and the surrounding neuroanatomic structures will aid in the selection of targets and the approach to programming. We propose to form a registry to track OCD DBS cases for future clinical study design. © 2013 International Neuromodulation Society.
Pan, Yixin; Wang, Linbin; Zhang, Yingying; Zhang, Chencheng; Qiu, Xian; Tan, Yuyan; Zhou, Haiyan; Sun, Bomin; Li, Dianyou
2018-01-01
Background: Impulse control disorder is not uncommon in patients with Parkinson’s disease (PD) who are treated with dopamine replacement therapy and subthalamic deep brain stimulation (DBS). Internal globus pallidus (GPi)-DBS is increasingly used, but its role in inhibitory control has rarely been explored. In this study, we evaluated the effect of GPi-DBS on inhibitory control in PD patients. Methods: A stop-signal paradigm was used to test response initiation, proactive inhibition, and reactive inhibition. The subjects enrolled in the experiment were 27 patients with PD, of whom 13 had received only drug treatment and 14 had received bilateral GPi-DBS in addition to conventional medical treatment and 15 healthy individuals. Results: Our results revealed that with GPi-DBS on, patients with PD showed significantly faster responses than the other groups in trials where it was certain that no stop signal would be presented. Proactive inhibition was significantly different in the surgical patients with GPi-DBS on versus when GPi-DBS was off, in surgical patients with GPi-DBS on versus drug-treated patients, and in healthy controls versus drug-treated patients. Correlation analyses revealed that when GPi-DBS was on, there was a statistically significant moderate positive relationship between proactive inhibition and dopaminergic medication. Conclusion: GPi-DBS may lead to an increase in response initiation speed and improve the dysfunctional proactive inhibitory control observed in PD patients. Our results may help us to understand the role of the GPi in cortical-basal ganglia circuits. PMID:29681869
Deep brain stimulation in uncommon tremor disorders: indications, targets, and programming.
Artusi, Carlo Alberto; Farooqi, Ashar; Romagnolo, Alberto; Marsili, Luca; Balestrino, Roberta; Sokol, Leonard L; Wang, Lily L; Zibetti, Maurizio; Duker, Andrew P; Mandybur, George T; Lopiano, Leonardo; Merola, Aristide
2018-03-06
In uncommon tremor disorders, clinical efficacy and optimal anatomical targets for deep brain stimulation (DBS) remain inadequately studied and insufficiently quantified. We performed a systematic review of PubMed.gov and ClinicalTrials.gov. Relevant articles were identified using the following keywords: "tremor", "Holmes tremor", "orthostatic tremor", "multiple sclerosis", "multiple sclerosis tremor", "neuropathy", "neuropathic tremor", "fragile X-associated tremor/ataxia syndrome", and "fragile X." We identified a total of 263 cases treated with DBS for uncommon tremor disorders. Of these, 44 had Holmes tremor (HT), 18 orthostatic tremor (OT), 177 multiple sclerosis (MS)-associated tremor, 14 neuropathy-associated tremor, and 10 fragile X-associated tremor/ataxia syndrome (FXTAS). DBS resulted in favorable, albeit partial, clinical improvements in HT cases receiving Vim-DBS alone or in combination with additional targets. A sustained improvement was reported in OT cases treated with bilateral Vim-DBS, while the two cases treated with unilateral Vim-DBS demonstrated only a transient effect. MS-associated tremor responded to dual-target Vim-/VO-DBS, but the inability to account for the progression of MS-associated disability impeded the assessment of its long-term clinical efficacy. Neuropathy-associated tremor substantially improved with Vim-DBS. In FXTAS patients, while Vim-DBS was effective in improving tremor, equivocal results were observed in those with ataxia. DBS of select targets may represent an effective therapeutic strategy for uncommon tremor disorders, although the level of evidence is currently in its incipient form and based on single cases or limited case series. An international registry is, therefore, warranted to clarify selection criteria, long-term results, and optimal surgical targets.
Speed effects of deep brain stimulation for Parkinson's disease.
Klostermann, Fabian; Wahl, Michael; Marzinzik, Frank; Vesper, Jan; Sommer, Werner; Curio, Gabriel
2010-12-15
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) accelerates reaction time (RT) in patients with Parkinson's disease (PD), particularly in tasks in which decisions on the response side have to be made. This might indicate that DBS speeds up both motor and nonmotor operations. Therefore, we studied the extent to which modifications of different processing streams could explain changes of RT under subthalamic DBS. Ten PD patients on-DBS and off-DBS and 10 healthy subjects performed a choice-response task (CRT), requiring either right or left finger button presses. At the same time, EEG recordings were performed, so that RTs could be assessed together with lateralized readiness potentials (LRP), indicative of movement preparation. Additionally, an oddball task (OT) was run, in which right finger responses to target stimuli were recorded along with cognitive P300 responses. Generally, PD patients off-DBS had longer RTs than controls. Subthalamic DBS accelerated RT only in CRT. This could largely be explained by analog shortenings of LRP. No DBS-dependent changes were identified in OT, neither on the level of RT nor on the level of P300 latencies. It follows that RT accelerations under DBS of the STN are predominantly due to effects on the timing of motor instead of nonmotor processes. This starting point explains why DBS gains of response speed are low in tasks in which reactions are initiated from an advanced level of movement preparation (as in OT), and high whenever motor responses have to be raised from scratch (as in CRT). © 2010 Movement Disorder Society.
de Koning, P P; Figee, M; Endert, E; van den Munckhof, P; Schuurman, P R; Storosum, J G; Denys, D; Fliers, E
2016-01-01
Improvement of obsessions and compulsions by deep brain stimulation (DBS) for obsessive-compulsive disorder (OCD) is often preceded by a rapid and transient mood elevation (hypomania). In a previous study we showed that improvement of mood by DBS for OCD is associated with a decreased activity of the hypothalamus–pituitary adrenal axis. The aim of our present study was to evaluate the time course of rapid clinical changes following DBS reactivation in more detail and to assess their association with additional neuroendocrine parameters. We included therapy-refractory OCD patients treated with DBS (>1 year) and performed a baseline assessment of symptoms, as well as plasma concentrations of thyroid-stimulating hormone (TSH), prolactin, growth hormone, copeptin and homovanillic acid. This was repeated after a 1-week DBS OFF condition. Next, we assessed the rapid effects of DBS reactivation by measuring psychiatric symptom changes using visual analog scales as well as repeated neuroendocrine measures after 30 min, 2 h and 6 h. OCD, anxiety and depressive symptoms markedly increased during the 1-week OFF condition and decreased again to a similar extent already 2 h after DBS reactivation. We found lower plasma prolactin (41% decrease, P=0.003) and TSH (39% decrease, P=0.003) levels during DBS OFF, which increased significantly already 30 min after DBS reactivation. The rapid and simultaneous increase in TSH and prolactin is likely to result from stimulation of hypothalamic thyrotropin-releasing hormone (TRH), which may underlie the commonly observed transient mood elevation following DBS. PMID:26812043
Gunalan, Kabilar; Chaturvedi, Ashutosh; Howell, Bryan; Duchin, Yuval; Lempka, Scott F; Patriat, Remi; Sapiro, Guillermo; Harel, Noam; McIntyre, Cameron C
2017-01-01
Deep brain stimulation (DBS) is an established clinical therapy and computational models have played an important role in advancing the technology. Patient-specific DBS models are now common tools in both academic and industrial research, as well as clinical software systems. However, the exact methodology for creating patient-specific DBS models can vary substantially and important technical details are often missing from published reports. Provide a detailed description of the assembly workflow and parameterization of a patient-specific DBS pathway-activation model (PAM) and predict the response of the hyperdirect pathway to clinical stimulation. Integration of multiple software tools (e.g. COMSOL, MATLAB, FSL, NEURON, Python) enables the creation and visualization of a DBS PAM. An example DBS PAM was developed using 7T magnetic resonance imaging data from a single unilaterally implanted patient with Parkinson's disease (PD). This detailed description implements our best computational practices and most elaborate parameterization steps, as defined from over a decade of technical evolution. Pathway recruitment curves and strength-duration relationships highlight the non-linear response of axons to changes in the DBS parameter settings. Parameterization of patient-specific DBS models can be highly detailed and constrained, thereby providing confidence in the simulation predictions, but at the expense of time demanding technical implementation steps. DBS PAMs represent new tools for investigating possible correlations between brain pathway activation patterns and clinical symptom modulation.
Miocinovic, Svjetlana; Lempka, Scott F; Russo, Gary S; Maks, Christopher B; Butson, Christopher R; Sakaie, Ken E; Vitek, Jerrold L; McIntyre, Cameron C
2009-03-01
Deep brain stimulation (DBS) is an established therapy for the treatment of Parkinson's disease and shows great promise for numerous other disorders. While the fundamental purpose of DBS is to modulate neural activity with electric fields, little is known about the actual voltage distribution generated in the brain by DBS electrodes and as a result it is difficult to accurately predict which brain areas are directly affected by the stimulation. The goal of this study was to characterize the spatial and temporal characteristics of the voltage distribution generated by DBS electrodes. We experimentally recorded voltages around active DBS electrodes in either a saline bath or implanted in the brain of a non-human primate. Recordings were made during voltage-controlled and current-controlled stimulation. The experimental findings were compared to volume conductor electric field models of DBS parameterized to match the different experiments. Three factors directly affected the experimental and theoretical voltage measurements: 1) DBS electrode impedance, primarily dictated by a voltage drop at the electrode-electrolyte interface and the conductivity of the tissue medium, 2) capacitive modulation of the stimulus waveform, and 3) inhomogeneity and anisotropy of the tissue medium. While the voltage distribution does not directly predict the neural response to DBS, the results of this study do provide foundational building blocks for understanding the electrical parameters of DBS and characterizing its effects on the nervous system.
Kraemer, Felicitas
2013-01-01
In this article, I explore select case studies of Parkinson patients treated with deep brain stimulation (DBS) in light of the notions of alienation and authenticity. While the literature on DBS has so far neglected the issues of authenticity and alienation, I argue that interpreting these cases in terms of these concepts raises new issues for not only the philosophical discussion of neuro-ethics of DBS, but also for the psychological and medical approach to patients under DBS. In particular, I suggest that the experience of alienation and authenticity varies from patient to patient with DBS. For some, alienation can be brought about by neurointerventions because patients no longer feel like themselves. But, on the other hand, it seems alienation can also be cured by DBS as other patients experience their state of mind as authentic under treatment and retrospectively regard their former lives without stimulation as alienated. I argue that we must do further research on the relevance of authenticity and alienation to patients treated with DBS in order to gain a deeper philosophical understanding, and to develop the best evaluative criterion for the behavior of DBS patients.
Voon, Valerie; Droux, Fabien; Chabardes, Stephan; Bougerol, Thierry; Kohl, Sina; David, Olivier; Krack, Paul; Polosan, Mircea
2018-07-01
Our daily decisions involve an element of risk, a behavioral process that is potentially modifiable. Here we assess the role of the associative-limbic subthalamic nucleus (STN) in obsessive compulsive disorder (OCD) testing on and off deep-brain stimulation (DBS) on anticipatory risk taking to obtain rewards and avoid losses. We assessed 12 OCD STN DBS in a randomized double-blind within-subject cross-over design. STN DBS decreased risk taking to rewards (p = 0.02) and greater risk taking to rewards was positively correlated with OCD severity (p = 0.01) and disease duration (p = 0.01). STN DBS was also associated with impaired subjective discrimination of loss magnitude (p < 0.05), an effect mediated by acute DBS rather than chronic DBS. We highlight a role for the STN in mediating dissociable valence prospects on risk seeking. STN stimulation decreases risk taking to rewards and impairs discrimination of loss magnitude. These findings may have implications for behavioral symptoms related to STN DBS and the potential for STN DBS for the treatment of psychiatric disorders. Copyright © 2018. Published by Elsevier Ltd.
Spieles-Engemann, A. L.; Behbehani, M. M.; Collier, T. J.; Wohlgenant, S. L.; Steece-Collier, K.; Paumier, K.; Daley, B. F.; Gombash, S.; Madhavan, L.; Mandybur, G. T.; Lipton, J.W.; Terpstra, B.T.; Sortwell, C.E.
2010-01-01
Deep brain stimulation of the subthalamic nucleus (STN-DBS) is efficacious in treating the motor symptoms of Parkinson’s disease (PD). However, the impact of STN-DBS on the progression of PD is unknown. Previous preclinical studies have demonstrated that STN-DBS can attenuate the degeneration of a relatively intact nigrostriatal system from dopamine (DA)-depleting neurotoxins. The present study examined whether STN-DBS can provide neuroprotection in the face of prior significant nigral DA neuron loss similar to PD patients at the time of diagnosis. STN-DBS between two and four weeks after intrastriatal 6-hydroxydopamine (6-OHDA) provided significant sparing of DA neurons in the SN of rats. This effect was not due to inadvertent lesioning of the STN and was dependent upon proper electrode placement. Since STN-DBS appears to have significant neuroprotective properties, initiation of STN-DBS earlier in the course of PD may provide added neuroprotective benefits in addition to its ability to provide symptomatic relief. PMID:20307668
Pohodich, Amy E; Yalamanchili, Hari; Raman, Ayush T; Wan, Ying-Wooi; Gundry, Michael; Hao, Shuang; Jin, Haijing; Tang, Jianrong; Liu, Zhandong
2018-01-01
Clinical trials are currently underway to assess the efficacy of forniceal deep brain stimulation (DBS) for improvement of memory in Alzheimer’s patients, and forniceal DBS has been shown to improve learning and memory in a mouse model of Rett syndrome (RTT), an intellectual disability disorder caused by loss-of-function mutations in MECP2. The mechanism of DBS benefits has been elusive, however, so we assessed changes in gene expression, splice isoforms, DNA methylation, and proteome following acute forniceal DBS in wild-type mice and mice lacking Mecp2. We found that DBS upregulates genes involved in synaptic function, cell survival, and neurogenesis and normalized expression of ~25% of the genes altered in Mecp2-null mice. Moreover, DBS induced expression of 17–24% of the genes downregulated in other intellectual disability mouse models and in post-mortem human brain tissue from patients with Major Depressive Disorder, suggesting forniceal DBS could benefit individuals with a variety of neuropsychiatric disorders. PMID:29570050
Wagle Shukla, Aparna; Okun, Michael S
2016-01-01
Deep brain stimulation (DBS) therapy is a widely used brain surgery that can be applied for many neurological and psychiatric disorders. DBS is American Food and Drug Administration approved for medication refractory Parkinson's disease, essential tremor and dystonia. Although DBS has shown consistent success in many clinical trials, the therapy has limitations and there are well-recognized complications. Thus, only carefully selected patients are ideal candidates for this surgery. Over the last two decades, there have been significant advances in clinical knowledge on DBS. In addition, the surgical techniques and technology related to DBS has been rapidly evolving. The goal of this review is to describe the current status of DBS in the context of movement disorders, outline the mechanisms of action for DBS in brief, discuss the standard surgical and imaging techniques, discuss the patient selection and clinical outcomes in each of the movement disorders, and finally, introduce the recent advancements from a clinical and technological perspective.
Quinn, Davin K; Rees, Caleb; Brodsky, Aaron; Deligtisch, Amanda; Evans, Daniel; Khafaja, Mohamad; Abbott, Christopher C
2014-09-01
The presence of a deep brain stimulator (DBS) in a patient who develops neuropsychiatric symptoms poses unique diagnostic challenges and questions for the treating psychiatrist. Catatonia has been described only once, during DBS implantation, but has not been reported in a successfully implanted DBS patient. We present a case of a patient with bipolar disorder and renal transplant who developed catatonia after DBS for essential tremor. The patient was successfully treated for catatonia with lorazepam and electroconvulsive therapy after careful diagnostic workup. Electroconvulsive therapy has been successfully used with DBS in a handful of cases, and certain precautions may help reduce potential risk. Catatonia is a rare occurrence after DBS but when present may be safely treated with standard therapies such as lorazepam and electroconvulsive therapy.
Motta, Irene; Filocamo, Mirella; Poggiali, Erika; Stroppiano, Marina; Dragani, Alfredo; Consonni, Dario; Barcellini, Wilma; Gaidano, Gianluca; Facchini, Luca; Specchia, Giorgina; Cappellini, Maria Domenica
2016-04-01
Gaucher disease (GD) is the most common lysosomal disorder resulting from deficient activity of the β-glucosidase enzyme that causes accumulation of glucosylceramide in the macrophage-monocyte system. Notably, because of non-specific symptoms and a lack of awareness, patients with GD experience long diagnostic delays. The aim of this study was to apply a diagnostic algorithm to identify GD type 1 among adults subjects referred to Italian haematology outpatient units because of splenomegaly and/or thrombocytopenia and, eventually, to estimate the prevalence of GD in this selected population. One hundred and ninety-six subjects (61 females, 135 males; mean age 47.8 ± 18.2 years) have been enrolled in the study and tested for β-glucosidase enzyme activity on dried blood spot (DBS). Seven of 196 patients have been diagnosed with GD, (5 females and 2 males) with mean age 31.8 ± 8.2 years, with a prevalence of 3.6% (with a prevalence of 3.6% (I95% CI 1.4-7.2; 1/28 patients) in this population. These results show that the use of an appropriate diagnostic algorithm and a simple diagnostic method, such as DBS, are important tools to facilitate the diagnosis of a rare disease even for not disease-expert physicians. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mondillon, Laurie; Mermillod, Martial; Musca, Serban C; Rieu, Isabelle; Vidal, Tiphaine; Chambres, Patrick; Auxiette, Catherine; Dalens, Hélène; Marie Coulangeon, Louise; Jalenques, Isabelle; Lemaire, Jean-Jacques; Ulla, Miguel; Derost, Philippe; Marques, Ana; Durif, Franck
2012-10-01
Deep brain stimulation of the subthalamic nucleus (DBS) is a widely used surgical technique to suppress motor symptoms in Parkinson's disease (PD), and as such improves patients' quality of life. However, DBS may produce emotional disorders such as a reduced ability to recognize emotional facial expressions (EFE). Previous studies have not considered the fact that DBS and l-dopa medication can have differential, common, or complementary consequences on EFE processing. A thorough way of investigating the effect of DBS and l-dopa medication in greater detail is to compare patients' performances after surgery, with the two therapies either being administered ('on') or not administered ('off'). We therefore used a four-condition (l-dopa 'on'/DBS 'on', l-dopa 'on'/DBS 'off', l-dopa 'off'/DBS 'on', and l-dopa 'off'/DBS 'off') EFE recognition paradigm and compared implanted PD patients to healthy controls. The results confirmed those of previous studies, yielding a significant impairment in the detection of some facial expressions relative to controls. Disgust recognition was impaired when patients were 'off' l-dopa and 'on' DBS, and fear recognition impaired when 'off' of both therapies. More interestingly, the combined effect of both DBS and l-dopa administration seems much more beneficial for EFE recognition than the separate administration of each individual therapy. We discuss the implications of these findings in the light of the inverted U curve function that describes the differential effects of dopamine level on the right orbitofrontal cortex (OFC). We propose that, while l-dopa could "overdose" in dopamine the ventral stream of the OFC, DBS would compensate for this over-activation by decreasing OFC activity, thereby restoring the necessary OFC-amygdala interaction. Another finding is that, when collapsing over all treatment conditions, PD patients recognized more neutral faces than the matched controls, a result that concurs with embodiment theories. Copyright © 2012 Elsevier Ltd. All rights reserved.
Giacino, Joseph; Fins, Joseph J; Machado, Andre; Schiff, Nicholas D
2012-07-01
Central thalamic deep brain stimulation (CT-DBS) may have therapeutic potential to improve behavioral functioning in patients with severe traumatic brain injury (TBI), but its use remains experimental. Current research suggests that the central thalamus plays a critical role in modulating arousal during tasks requiring sustained attention, working memory, and motor function. The aim of the current article is to review the methodology used in the CT-DBS protocol developed by our group, outline the challenges we encountered and offer suggestions for future DBS trials in this population. RATIONAL FOR CT-DBS IN TBI: CT-DBS may therefore be able to stimulate these functions by eliciting action potentials that excite thalamocortical and thalamostriatal pathways. Because patients in chronic minimally conscious state (MCS) have a very low probability of regaining functional independence, yet often have significant sparing of cortical connectivity, they may represent a particularly appropriate target group for CT-DBS. PIlOT STUDY RESULTS: We have conducted a series of single-subject studies of CT-DBS in patients with chronic posttraumatic MCS, with 24-month follow-up. Outcomes were measured using the Coma Recovery Scale-Revised as well as a battery of secondary outcome measures to capture more granular changes. Findings from our index case suggest that CT-DBS can significantly increase functional communication, motor performance, feeding, and object naming in the DBS on state, with performance in some domains remaining above baseline even after DBS was turned off. The use of CT-DBS in patients in MCS, however, presents challenges at almost every step, including during surgical planning, outcome measurement, and postoperative care. Additionally, given the difficulties of obtaining informed consent from patients in MCS and the experimental nature of the treatment, a robust, scientifically rooted ethical framework is resented for pursuing this line of work. © 2012 International Neuromodulation Society.
Anticonvulsant serotonergic and deep brain stimulation in anterior thalamus.
Mirski, Marek A; Ziai, Wendy C; Chiang, Jason; Hinich, Melvin; Sherman, David
2009-01-01
Anterior thalamus (AN) has been shown to mediate seizures in both focal and generalized models. Specific regional increase in AN serotonergic activity was observed following AN-DBS in our pentylenetetrazol (PTZ) rodent model of acute seizures, and this increase may inhibit seizures and contribute to the mechanism of anticonvulsant DBS. Anesthetized rats with AN-directed dialysis cannula with scalp/depth EEG were infused with PTZ at 5.5mg/(kg min) until an EEG seizure occurred. Eight experimental groups of AN-dialysis infusion were evaluated: controls (dialysate-only), 10 and 100 microM serotonin 5-HT(7) agonist 5-carboxamidotryptamine (5-CT), 1, 10 and 100 microM serotonin antagonist methysergide (METH), AN-DBS, and 100 microM METH+AN-DBS. Latency for seizures in control animals was 3,120+/-770 s (S.D.); AN-DBS delayed onset to 5018+/-1100 (p<0.01). AN-directed 5-CT increased latency in dose-dependent fashion: 3890+/-430 and 4247+/-528 (p<0.05). Methysergide had an unexpected protective effect at low-dose (3908+/-550, p<0.05) but not at 100 microM (2687+/-1079). The anticonvulsant action of AN-DBS was blocked by prior dialysis using 100 microM METH. Surface EEG burst count and nonlinear analysis (H-Statistic) noted significant (p<0.05) increased pre-ictal epileptiform bursts in 5-CT, methysergide, but not DBS group compared to control. Increased serotonergic activity in AN raised PTZ seizure threshold, similar to DBS, but without preventing cortical bursting. 5-Carboxamidotryptamine, a 5-HT(7) agonist, demonstrated dose-dependent seizure inhibition. Methysergide proved to have an inverse, dose-dependent agonist property, antagonizing the action of AN-DBS at the highest dose. Anticonvulsant AN-DBS may in part act to selectively alter serotonin neurotransmission to raise seizure threshold.
Walter, Uwe; Müller, Jan-Uwe; Rösche, Johannes; Kirsch, Michael; Grossmann, Annette; Benecke, Reiner; Wittstock, Matthias; Wolters, Alexander
2016-03-01
A combination of preoperative magnetic resonance imaging (MRI) with real-time transcranial ultrasound, known as fusion imaging, may improve postoperative control of deep brain stimulation (DBS) electrode location. Fusion imaging, however, employs a weak magnetic field for tracking the position of the ultrasound transducer and the patient's head. Here we assessed its feasibility, safety, and clinical relevance in patients with DBS. Eighteen imaging sessions were conducted in 15 patients (7 women; aged 52.4 ± 14.4 y) with DBS of subthalamic nucleus (n = 6), globus pallidus interna (n = 5), ventro-intermediate (n = 3), or anterior (n = 1) thalamic nucleus and clinically suspected lead displacement. Minimum distance between DBS generator and magnetic field transmitter was kept at 65 cm. The pre-implantation MRI dataset was loaded into the ultrasound system for the fusion imaging examination. The DBS lead position was rated using validated criteria. Generator DBS parameters and neurological state of patients were monitored. Magnetic resonance-ultrasound fusion imaging and volume navigation were feasible in all cases and provided with real-time imaging capabilities of DBS lead and its location within the superimposed magnetic resonance images. Of 35 assessed lead locations, 30 were rated optimal, three suboptimal, and two displaced. In two cases, electrodes were re-implanted after confirming their inappropriate location on computed tomography (CT) scan. No influence of fusion imaging on clinical state of patients, or on DBS implantable pulse generator function, was found. Magnetic resonance-ultrasound real-time fusion imaging of DBS electrodes is safe with distinct precautions and improves assessment of electrode location. It may lower the need for repeated CT or MRI scans in DBS patients. © 2015 International Parkinson and Movement Disorder Society.
Jech, Robert; Růzicka, Evzen; Urgosík, Dusan; Serranová, Tereza; Volfová, Markéta; Nováková, Olga; Roth, Jan; Dusek, Petr; Mecír, Petr
2006-05-01
We studied changes of the EEG spectral power induced by deep brain stimulation (DBS) of the subthalamic nucleus (STN) in patients with Parkinson's disease (PD). Also analyzed were changes of visual evoked potentials (VEP) with DBS on and off. Eleven patients with advanced PD treated with bilateral DBS STN were examined after an overnight withdrawal of L-DOPA and 2 h after switching off the neurostimulators. All underwent clinical examination followed by resting EEG and VEP recordings, a procedure repeated after DBS STN was switched on. With DBS switched on, the dominant EEG frequency increased from 9.44+/-1.3 to 9.71+/-1.3 Hz (P<0.01) while its relative spectral power dropped by 11% on average (P<0.05). Switching on the neurostimulators caused a decrease in the N70/P100 amplitude of the VEP (P<0.01), which inversely correlated with the intensity of DBS (black-and-white pattern: P<0.01; color pattern: P<0.05). Despite artifacts generated by neurostimulators, the VEP and resting EEG were suitable for the detection of effects related to DBS STN. The acceleration of dominant frequency in the alpha band may be evidence of DBS STN influence on speeding up of intracortical oscillations. The spectral power decrease, seen mainly in the fronto-central region, might reflect a desynchronization in the premotor and motor circuits, though no movement was executed. Similarly, desynchronization of the cortical activity recorded posteriorly may by responsible for the VEP amplitude decrease implying DBS STN-related influence even on the visual system. Changes in idling EEG activity observed diffusely over scalp together with involvement of the VEP suggest that the effects of DBS STN reach far beyond the motor system influencing the basic mechanisms of rhythmic cortical oscillations.
Leoutsakos, Jeannie-Marie S; Yan, Haijuan; Anderson, William S; Asaad, Wael F; Baltuch, Gordon; Burke, Anna; Chakravarty, M Mallar; Drake, Kristen E; Foote, Kelly D; Fosdick, Lisa; Giacobbe, Peter; Mari, Zoltan; McAndrews, Mary Pat; Munro, Cynthia A; Oh, Esther S; Okun, Michael S; Pendergrass, Jo Cara; Ponce, Francisco A; Rosenberg, Paul B; Sabbagh, Marwan N; Salloway, Stephen; Tang-Wai, David F; Targum, Steven D; Wolk, David; Lozano, Andres M; Smith, Gwenn S; Lyketsos, Constantine G
2018-06-09
Given recent challenges in developing new treatments for Alzheimer dementia (AD), it is vital to explore alternate treatment targets, such as neuromodulation for circuit dysfunction. We previously reported an exploratory Phase IIb double-blind trial of deep brain stimulation targeting the fornix (DBS-f) in mild AD (the ADvance trial). We reported safety but no clinical benefits of DBS-f versus the delayed-on (sham) treatment in 42 participants after one year. However, secondary post hoc analyses of the one-year data suggested a possible DBS-f benefit for participants≥65 years. To examine the long-term safety and clinical effects of sustained and delayed-on DBS-f treatment of mild AD after two years. 42 participants underwent implantation of DBS-f electrodes, with half randomized to active DBS-f stimulation (early on) for two years and half to delayed-on (sham) stimulation after 1 year to provide 1 year of active DBS-f stimulation (delayed on). We evaluated safety and clinical outcomes over the two years of the trial. DBS-f had a favorable safety profile with similar rates of adverse events across both trial phases (years 1 and 2) and between treatment arms. There were no differences between treatment arms on any primary clinical outcomes. However, post-hoc age group analyses suggested a possible benefit among older (>65) participants. DBS-f was safe. Additional study of mechanisms of action and methods for titrating stimulation parameters will be needed to determine if DBS has potential as an AD treatment. Future efficacy studies should focus on patients over age 65.
Park, Hae-Jeong; Park, Bumhee; Kim, Hae Yu; Oh, Maeng-Keun; Kim, Joong Il; Yoon, Misun; Lee, Jong Doo; Chang, Jin Woo
2015-05-01
As Parkinson's disease (PD) can be considered a network abnormality, the effects of deep brain stimulation (DBS) need to be investigated in the aspect of networks. This study aimed to examine how DBS of the bilateral subthalamic nucleus (STN) affects the motor networks of patients with idiopathic PD during motor performance and to show the feasibility of the network analysis using cross-sectional positron emission tomography (PET) images in DBS studies. We obtained [¹⁵O]H₂O PET images from ten patients with PD during a sequential finger-to-thumb opposition task and during the resting state, with DBS-On and DBS-Off at STN. To identify the alteration of motor networks in PD and their changes due to STN-DBS, we applied independent component analysis (ICA) to all the cross-sectional PET images. We analysed the strength of each component according to DBS effects, task effects and interaction effects. ICA blindly decomposed components of functionally associated distributed clusters, which were comparable to the results of univariate statistical parametric mapping. ICA further revealed that STN-DBS modifies usage-strengths of components corresponding to the basal ganglia-thalamo-cortical circuits in PD patients by increasing the hypoactive basal ganglia and by suppressing the hyperactive cortical motor areas, ventrolateral thalamus and cerebellum. Our results suggest that STN-DBS may affect not only the abnormal local activity, but also alter brain networks in patients with PD. This study also demonstrated the usefulness of ICA for cross-sectional PET data to reveal network modifications due to DBS, which was not observable using the subtraction method.
Bergfeld, Isidoor O; Mantione, Mariska; Hoogendoorn, Mechteld L C; Horst, Ferdinand; Notten, Peter; Schuurman, P Richard; Denys, Damiaan
Electroconvulsive Therapy (ECT) and Deep Brain Stimulation (DBS) are effective treatments for patients with treatment-resistant depression (TRD). However, a common side effect of ECT is autobiographical memory loss (e.g., personal experiences), whereas the impact of DBS on autobiographical memories has never been established. Comparing autobiographical memories following DBS and ECT. In two hospitals in The Netherlands, we interviewed 25 TRD patients treated with DBS of the ventral anterior limb of the internal capsule (vALIC), 14 TRD patients treated with ECT and 22 healthy controls (HC) with the Autobiographical Memory Inventory - Short Form (AMI-SF) in a prospective, longitudinal study between March 2010 and August 2016. Patients treated with DBS were interviewed before surgery, after surgery, and twice during treatment over 122.7 (SD: ±22.2) weeks. Patients treated with ECT were tested before ECT, after six right unilateral (RUL) ECT sessions and twice following ECT over 65.1 (±9.3) weeks. Controls were tested four times over 81.5 (±15.6) weeks. Compared to HC, the AMI-SF score decreased faster in both TRD groups (P < 0.001). More specifically, AMI-SF score decreased in a comparable rate as HC after DBS surgery, but decreased more during treatment. The AMI-SF decrease in the ECT group was larger than both the DBS and HC groups. Both ECT and vALIC DBS result in a faster autobiographical memory decline compared to HC. DBS might have a negative impact on autobiographical memories, although less so than ECT. Future work should dissect whether DBS or characteristics of TRD cause this decline. Copyright © 2017 Elsevier Inc. All rights reserved.
Eugster, Lukas; Oberholzer, Michael; Debove, Ines; Lachenmayer, M. Lenard; Mathis, Johannes; Pollo, Claudio; Schüpbach, W. M. Michael; Bassetti, Claudio L.
2017-01-01
Objectives Sleep-wake disturbances (SWD) are frequent in Parkinson’s disease (PD). The effect of deep brain stimulation (DBS) on SWD is poorly known. In this study we examined the subjective and objective sleep-wake profile and the quality of life (QoL) of PD patients in the context of subthalamic DBS. Patients and methods We retrospectively analyzed data from PD patients and candidates for DBS in the nucleus suthalamicus (STN). Pre-DBS, sleep-wake assessments included subjective and objective (polysomnography, vigilance tests and actigraphy) measures. Post-DBS, subjective measures were collected. QoL was assessed using the Parkinson’s Disease Questionnaire (PDQ-39) and the RAND SF-36-item Health Survey (RAND SF-36). Results Data from 74 PD patients (62% male, mean age 62.2 years, SD = 8.9) with a mean UPDRS-III (OFF) of 34.2 (SD = 14.8) and 11.8 (SD = 4.5) years under PD treatment were analyzed. Pre-DBS, daytime sleepiness, apathy, fatigue and depressive symptoms were present in 49%, 34%, 38% and 25% of patients respectively but not always as co-occurring symptoms. Sleep-wake disturbances were significantly correlated with QoL scores. One year after STN DBS, motor signs, QoL and sleepiness improved but apathy worsened. Changes in QoL were associated with changes in sleepiness and apathy but baseline sleep-wake functions were not predictive of STN DBS outcome. Conclusion In PD patients presenting for STN DBS, subjective and objective sleep-wake disturbances are common and have a negative impact on QoL before and after neurosurgery. Given the current preliminary evidence, prospective observational studies assessing subjective and objective sleep-wake variables prior to and after DBS are needed. PMID:29253029
Dandekar, Manoj P; Luse, Dustin; Hoffmann, Carson; Cotton, Patrick; Peery, Travis; Ruiz, Christian; Hussey, Caroline; Giridharan, Vijayasree V; Soares, Jair C; Quevedo, Joao; Fenoy, Albert J
2017-08-01
Among several potential neuroanatomical targets pursued for deep brain stimulation (DBS) for treating those with treatment-resistant depression (TRD), the superolateral-branch of the medial forebrain bundle (MFB) is emerging as a privileged location. We investigated the antidepressant-like phenotypic and chemical changes associated with reward-processing dopaminergic systems in rat brains after MFB-DBS. Male Wistar rats were divided into three groups: sham-operated, DBS-Off, and DBS-On. For DBS, a concentric bipolar electrode was stereotactically implanted into the right MFB. Exploratory activity and depression-like behavior were evaluated using the open-field and forced-swimming test (FST), respectively. MFB-DBS effects on the dopaminergic system were evaluated using immunoblotting for tyrosine hydroxylase (TH), dopamine transporter (DAT), and dopamine receptors (D1-D5), and high-performance liquid chromatography for quantifying dopamine, 3,4-dihydroxyphenylacetic acid (DOPAC), and homovanillic acid (HVA) in brain homogenates of prefrontal cortex (PFC), hippocampus, amygdala, and nucleus accumbens (NAc). Animals receiving MFB-DBS showed a significant increase in swimming time without alterations in locomotor activity, relative to the DBS-Off (p<0.039) and sham-operated groups (p<0.014), indicating an antidepressant-like response. MFB-DBS led to a striking increase in protein levels of dopamine D2 receptors and DAT in the PFC and hippocampus, respectively. However, we did not observe appreciable differences in the expression of other dopamine receptors, TH, or in the concentrations of dopamine, DOPAC, and HVA in PFC, hippocampus, amygdala, and NAc. This study was not performed on an animal model of TRD. MFB-DBS rescues the depression-like phenotypes and selectively activates expression of dopamine receptors in brain regions distant from the target area of stimulation. Copyright © 2017. Published by Elsevier B.V.
Haegelen, Claire; García-Lorenzo, Daniel; Le Jeune, Florence; Péron, Julie; Gibaud, Bernard; Riffaud, Laurent; Brassier, Gilles; Barillot, Christian; Vérin, Marc; Morandi, Xavier
2010-03-01
The subthalamic nucleus (STN) has become an effective target of deep-brain stimulation (DBS) in severely disabled patients with advanced Parkinson's disease (PD). Clinical studies have reported DBS-induced adverse effects on cognitive functions, mood, emotion and behavior. STN DBS seems to interfere with the limbic functions of the basal ganglia, but the limbic effects of STN DBS are controversial. We measured prospectively resting regional cerebral metabolism (rCMb) with 18-fluorodeoxyglucose and PET, and resting regional cerebral blood flow (rCBF) with HMPAO and SPECT in six patients with Parkinson's disease. We compared PET and SPECT 1 month before and 3 months after STN DBS. On cerebral MRI, 13 regions of interest (ROI) were manually delineated slice by slice in frontal and limbic lobes. We obtained mean rCBF and rCMb values for each ROI and the whole brain. We normalized rCBF and rCMB values to ones for the whole brain volume, which we compared before and following STN DBS. No significant difference emerged in the SPECT analysis. PET analysis revealed a significant decrease in rCMb following STN DBS in the superior frontal gyri and left and right dorsolateral prefrontal cortex (p < 0.05). A non-significant decrease in rCMb in the left anterior cingulate gyrus appeared following STN DBS (p = 0.075). Our prospective SPECT and PET study revealed significantly decreased glucose metabolism of the two superior frontal gyri without any attendant perfusion changes following STN DBS. These results suggest that STN DBS may change medial prefrontal function and therefore the integration of limbic information, either by disrupting emotional processes within the STN, or by hampering the normal function of a limbic circuit.
Kibleur, Astrid; Polosan, Mircea; Favre, Pauline; Rudrauf, David; Bougerol, Thierry; Chabardès, Stéphan; David, Olivier
2017-02-01
Deep brain stimulation (DBS) of the subgenual cingulate gyrus (area CG25) is beneficial in treatment resistant depression. Though the mechanisms of action of Cg25 DBS remain largely unknown, it is commonly believed that Cg25 DBS modulates limbic activity of large networks to achieve thymic regulation of patients. To investigate how emotional attention is influenced by Cg25 DBS, we assessed behavioral and electroencephalographic (EEG) responses to an emotional Stroop task in 5 patients during ON and OFF stimulation conditions. Using EEG source localization, we found that the main effect of DBS was a reduction of neuronal responses in limbic regions (temporal pole, medial prefrontal and posterior cingulate cortices) and in ventral visual areas involved in face processing. In the dynamic causal modeling (DCM) approach, the changes of the evoked response amplitudes are assumed to be due to changes of long range connectivity induced by Cg25 DBS. Here, using a simplified neural mass model that did not take explicitly into account the cytoarchitecture of the considered brain regions, we showed that the remote action of Cg25 DBS could be explained by a reduced top-down effective connectivity of the amygdalo-temporo-polar complex. Overall, our results thus indicate that Cg25 DBS during the emotional Stroop task causes a decrease of top-down limbic influence on the ventral visual stream itself, rather than a modulation of prefrontal cognitive processes only. Tuning down limbic excitability in relation to sensory processing might be one of the biological mechanisms through which Cg25 DBS produces positive clinical outcome in the treatment of resistant depression. Copyright © 2016 Elsevier Inc. All rights reserved.
Gopalakrishnan, Raghavan; Burgess, Richard C; Malone, Donald A; Lempka, Scott F; Gale, John T; Floden, Darlene P; Baker, Kenneth B; Machado, Andre G
2018-06-01
Poststroke pain syndrome (PSPS) is an often intractable disorder characterized by hemiparesis associated with unrelenting chronic pain. Although traditional analgesics have largely failed, integrative approaches targeting affective-cognitive spheres have started to show promise. Recently, we demonstrated that deep brain stimulation (DBS) of the ventral striatal area significantly improved the affective sphere of pain in patients with PSPS. In the present study, we examined whether electrophysiological correlates of pain anticipation were modulated by DBS that could serve as signatures of treatment effects. We recorded event-related fields (ERFs) of pain anticipation using magnetoencephalography (MEG) in 10 patients with PSPS preoperatively and postoperatively in DBS OFF and ON states. Simple visual cues evoked anticipation as patients awaited a painful (PS) or nonpainful stimulus (NPS) to the nonaffected or affected extremity. Preoperatively, ERFs showed no difference between PS and NPS anticipation to the affected extremity, possibly due to loss of salience in a network saturated by pain experience. DBS significantly modulated the early N1, consistent with improvements in affective networks involving restoration of salience and discrimination capacity. Additionally, DBS suppressed the posterior P2 (aberrant anticipatory anxiety) while enhancing the anterior N1 (cognitive and emotional regulation) in responders. DBS-induced changes in ERFs could potentially serve as signatures for clinical outcomes. NEW & NOTEWORTHY We examined the electrophysiological correlates of pain affect in poststroke pain patients who underwent deep brain stimulation (DBS) targeting the ventral striatal area under a randomized, controlled trial. DBS significantly modulated early event-related components, particularly N1 and P2, measured with magnetoencephalography during a pain anticipatory task, compared with baseline and the DBS-OFF condition, pointing to possible mechanisms of action. DBS-induced changes in event-related fields could potentially serve as biomarkers for clinical outcomes.
Deep brain stimulation, brain maps and personalized medicine: lessons from the human genome project.
Fins, Joseph J; Shapiro, Zachary E
2014-01-01
Although the appellation of personalized medicine is generally attributed to advanced therapeutics in molecular medicine, deep brain stimulation (DBS) can also be so categorized. Like its medical counterpart, DBS is a highly personalized intervention that needs to be tailored to a patient's individual anatomy. And because of this, DBS like more conventional personalized medicine, can be highly specific where the object of care is an N = 1. But that is where the similarities end. Besides their differing medical and surgical provenances, these two varieties of personalized medicine have had strikingly different impacts. The molecular variant, though of a more recent vintage has thrived and is experiencing explosive growth, while DBS still struggles to find a sustainable therapeutic niche. Despite its promise, and success as a vetted treatment for drug resistant Parkinson's Disease, DBS has lagged in broadening its development, often encountering regulatory hurdles and financial barriers necessary to mount an adequate number of quality trials. In this paper we will consider why DBS-or better yet neuromodulation-has encountered these challenges and contrast this experience with the more successful advance of personalized medicine. We will suggest that personalized medicine and DBS's differential performance can be explained as a matter of timing and complexity. We believe that DBS has struggled because it has been a journey of scientific exploration conducted without a map. In contrast to molecular personalized medicine which followed the mapping of the human genome and the Human Genome Project, DBS preceded plans for the mapping of the human brain. We believe that this sequence has given personalized medicine a distinct advantage and that the fullest potential of DBS will be realized both as a cartographical or electrophysiological probe and as a modality of personalized medicine.
Gunalan, Kabilar; Chaturvedi, Ashutosh; Howell, Bryan; Duchin, Yuval; Lempka, Scott F.; Patriat, Remi; Sapiro, Guillermo; Harel, Noam; McIntyre, Cameron C.
2017-01-01
Background Deep brain stimulation (DBS) is an established clinical therapy and computational models have played an important role in advancing the technology. Patient-specific DBS models are now common tools in both academic and industrial research, as well as clinical software systems. However, the exact methodology for creating patient-specific DBS models can vary substantially and important technical details are often missing from published reports. Objective Provide a detailed description of the assembly workflow and parameterization of a patient-specific DBS pathway-activation model (PAM) and predict the response of the hyperdirect pathway to clinical stimulation. Methods Integration of multiple software tools (e.g. COMSOL, MATLAB, FSL, NEURON, Python) enables the creation and visualization of a DBS PAM. An example DBS PAM was developed using 7T magnetic resonance imaging data from a single unilaterally implanted patient with Parkinson’s disease (PD). This detailed description implements our best computational practices and most elaborate parameterization steps, as defined from over a decade of technical evolution. Results Pathway recruitment curves and strength-duration relationships highlight the non-linear response of axons to changes in the DBS parameter settings. Conclusion Parameterization of patient-specific DBS models can be highly detailed and constrained, thereby providing confidence in the simulation predictions, but at the expense of time demanding technical implementation steps. DBS PAMs represent new tools for investigating possible correlations between brain pathway activation patterns and clinical symptom modulation. PMID:28441410
Kim, Joo Pyung; Min, Hoon-Ki; Knight, Emily J; Duffy, Penelope S; Abulseoud, Osama A; Marsh, Michael P; Kelsey, Katherine; Blaha, Charles D; Bennet, Kevin E; Frye, Mark A; Lee, Kendall H
2013-12-15
Deep brain stimulation (DBS) of the centromedian-parafascicular (CM-Pf) thalamic nuclei has been considered an option for treating Tourette syndrome. Using a large animal DBS model, this study was designed to explore the network effects of CM-Pf DBS. The combination of DBS and functional magnetic resonance imaging is a powerful means of tracing brain circuitry and testing the modulatory effects of electrical stimulation on a neuronal network in vivo. With a within-subjects design, we tested the proportional effects of CM and Pf DBS by manipulating current spread and varying stimulation contacts in healthy pigs (n = 5). Our results suggests that CM-Pf DBS has an inhibitory modulating effect in areas that have been suggested as contributing to impaired sensory-motor and emotional processing. The results also help to define the differential neural circuitry effects of the CM and Pf with evidence of prominent sensorimotor/associative effects for CM DBS and prominent limbic/associative effects for Pf DBS. Our results support the notion that stimulation of deep brain structures, such as the CM-Pf, modulates multiple networks with cortical effects. The networks affected by CM-Pf stimulation in this study reinforce the conceptualization of Tourette syndrome as a condition with psychiatric and motor symptoms and of CM-Pf DBS as a potentially effective tool for treating both types of symptoms. Copyright © 2013 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Effects of deep brain stimulation of the subthalamic nucleus on perceptual decision making.
Zaehle, Tino; Wagenbreth, Caroline; Voges, Jürgen; Heinze, Hans-Jochen; Galazky, Imke
2017-02-20
When faced with difficult decisions, people prefer to stay with the default. This status quo bias often leads to suboptimal choice behavior. Neurophysiological evidence suggests a pivot role of the Subthalamic Nucleus (STN) for overcoming such status quo bias in difficult decisions, but causal evidence is lacking. The present study investigated whether subthalamic deep brain stimulation (DBS) in patients with Parkinson's disease (PD) influences the status quo bias. Eighteen PD patients treated with STN-DBS performed a difficult perceptual decision task incorporating intrinsic status quo option. Patients were tested with (ON) and without (OFF) active STN stimulation. Our results show that DBS of the STN affected perceptual decision making in PD patients depending on the difficulty of decision. STN-DBS improved difficult perceptual decisions due to a selective increase in accuracy (hit rate) that was independent of response bias (no effect on false alarm rate). Furthermore, STN-DBS impacted status quo bias as a function of baseline impulsivity. In impulsive patients, STN-DBS increased the default bias, whereas in less impulsive PD patients, DBS of the STN reduced the status quo bias. In line with our hypothesis, STN-DBS selectively affected the tendency to stick with the default option on difficult decisions, and promoted increased decision accuracy. Moreover, we demonstrate the impact of baseline cognitive abilities on DBS-related performance changes in PD patients. Copyright © 2016 IBRO. Published by Elsevier Ltd. All rights reserved.
Computational modeling of an endovascular approach to deep brain stimulation
NASA Astrophysics Data System (ADS)
Teplitzky, Benjamin A.; Connolly, Allison T.; Bajwa, Jawad A.; Johnson, Matthew D.
2014-04-01
Objective. Deep brain stimulation (DBS) therapy currently relies on a transcranial neurosurgical technique to implant one or more electrode leads into the brain parenchyma. In this study, we used computational modeling to investigate the feasibility of using an endovascular approach to target DBS therapy. Approach. Image-based anatomical reconstructions of the human brain and vasculature were used to identify 17 established and hypothesized anatomical targets of DBS, of which five were found adjacent to a vein or artery with intraluminal diameter ≥1 mm. Two of these targets, the fornix and subgenual cingulate white matter (SgCwm) tracts, were further investigated using a computational modeling framework that combined segmented volumes of the vascularized brain, finite element models of the tissue voltage during DBS, and multi-compartment axon models to predict the direct electrophysiological effects of endovascular DBS. Main results. The models showed that: (1) a ring-electrode conforming to the vessel wall was more efficient at neural activation than a guidewire design, (2) increasing the length of a ring-electrode had minimal effect on neural activation thresholds, (3) large variability in neural activation occurred with suboptimal placement of a ring-electrode along the targeted vessel, and (4) activation thresholds for the fornix and SgCwm tracts were comparable for endovascular and stereotactic DBS, though endovascular DBS was able to produce significantly larger contralateral activation for a unilateral implantation. Significance. Together, these results suggest that endovascular DBS can serve as a complementary approach to stereotactic DBS in select cases.
Recent advances in deep brain stimulation in psychiatric disorders.
Clair, Anne-Hélène; Haynes, William; Mallet, Luc
2018-01-01
Deep brain stimulation (DBS) has been offered to patients suffering of severe and resistant neuropsychiatric disorders like Obsessive Compulsive Disorder (OCD), Gilles de la Tourette Syndrome (TS) and Major Depression (MDD). Modulation of several targets within the cortico-striato-thalamo-cortical circuits can lead to a decrease of symptom severity in those patients. This review focuses on the recent clinical outcomes in DBS in psychiatric disorders. Studies on OCD and TS are now focusing on the long-term effects of DBS, with encouraging results regarding not only the decrease of symptoms, but also quality of life. They also highlighted efficient adjuvant techniques, like cognitive and behavioural therapy and support programs, to enhance an often-partial response to DBS. The application of DBS for MDD is more recent and, despite encouraging initial open-label studies, two large randomised studies have failed to demonstrate an efficacy of DBS in MDD according to evidence-based medicine criteria. Last years, DBS was also tested in other resistant psychiatric disorders, as anorexia nervosa and addiction, with encouraging preliminary results. However, today, no target - whatever the disease - can meet the criteria for clinical efficacy as recently defined by an international committee for neurosurgery for psychiatric disorders. Consequently, DBS in psychiatric disorders still needs to proceed within the frame of clinical trials.
Green, Nikos; Bogacz, Rafal; Huebl, Julius; Beyer, Ann-Kristin; Kühn, Andrea A; Heekeren, Hauke R
2013-09-09
Neurocomputational models of optimal decision making ascribe a crucial role-the computation of conflict between choice alternatives-to the subthalamic nucleus (STN). Specifically, these models predict that deep brain stimulation (DBS) of the STN will diminish the influence of decision conflict on decision making. In this work, patients with Parkinson's disease judged the direction of motion in random dot stimuli while ON and OFF DBS. To induce decision conflict, we varied the task difficulty (motion coherence), leading to increased reaction time (RT) in trials with greater task difficulty in healthy subjects. Results indicate that DBS significantly influences performance for perceptual decisions under high decision conflict. RT increased substantially OFF DBS as the task became more difficult, and a diffusion model best accounted for behavioral data. In contrast, ON DBS, the influence of task difficulty on RT was significantly reduced and a race model best accounted for the observed data. Individual data fits of evidence accumulation models demonstrate different information processing under distinct DBS states. Furthermore, ON DBS, speed-accuracy tradeoffs affected the magnitude of decision criterion adjustment significantly less compared to OFF DBS. Together, these findings suggest a crucial role for the STN in adjusting decision making during high-conflict trials in perceptual decision making. Copyright © 2013 Elsevier Ltd. All rights reserved.
Oswal, Ashwini; Jha, Ashwani; Neal, Spencer; Reid, Alphonso; Bradbury, David; Aston, Peter; Limousin, Patricia; Foltynie, Tom; Zrinzo, Ludvic; Brown, Peter; Litvak, Vladimir
2016-01-01
Background Deep Brain Stimulation (DBS) is an effective treatment for several neurological and psychiatric disorders. In order to gain insights into the therapeutic mechanisms of DBS and to advance future therapies a better understanding of the effects of DBS on large-scale brain networks is required. New method In this paper, we describe an experimental protocol and analysis pipeline for simultaneously performing DBS and intracranial local field potential (LFP) recordings at a target brain region during concurrent magnetoencephalography (MEG) measurement. Firstly we describe a phantom setup that allowed us to precisely characterise the MEG artefacts that occurred during DBS at clinical settings. Results Using the phantom recordings we demonstrate that with MEG beamforming it is possible to recover oscillatory activity synchronised to a reference channel, despite the presence of high amplitude artefacts evoked by DBS. Finally, we highlight the applicability of these methods by illustrating in a single patient with Parkinson's disease (PD), that changes in cortical-subthalamic nucleus coupling can be induced by DBS. Comparison with existing approaches To our knowledge this paper provides the first technical description of a recording and analysis pipeline for combining simultaneous cortical recordings using MEG, with intracranial LFP recordings of a target brain nucleus during DBS. PMID:26698227
Penz, Marlene; Wekenborg, Magdalena K; Pieper, Lars; Beesdo-Baum, Katja; Walther, Andreas; Miller, Robert; Stalder, Tobias; Kirschbaum, Clemens
2018-06-01
The Dresden Burnout Study (DBS) is a 12-year longitudinal cohort study that aims to provide a description of the burnout syndrome on the basis of time and symptom criteria with a special focus on the search for biomarkers. Biological and psychosocial approaches are applied to examine the long-term course and consequences of burnout within a population-based German-speaking sample aged 18 to 68 years. Demographics and psychosocial data are generated by online assessments, including demographics and questionnaires on burnout, burnout-related constructs, work-environment, and health-related factors. The lab-based biomarker assessment includes endocrine, physiological, immunological, and epigenetic markers obtained from blood and hair samples. In addition, heart rate variability is also measured repeatedly. Within the first 2 years, the DBS collected psychosocial data from over 7,600 participants with biological data obtained from more than 800 individuals. During the following 10 years, detailed assessments of biomarkers and psychosocial factors will be collected in annual study waves. Results will be generated during the following decade. The findings of the DBS are expected to pave the road for an in-depth biopsychosocial characterization of burnout and to give insight into the long-term course and potential mental and physical health consequences of the burnout syndrome. Copyright © 2018 John Wiley & Sons, Ltd.
Cukiert, Arthur; Cukiert, Cristine Mella; Argentoni-Baldochi, Meire; Baise, Carla; Forster, Cássio Roberto; Mello, Valeria Antakli; Burattini, José Augusto; Lima, Alessandra Moura
2011-12-01
Deep brain stimulation (DBS) has been used in an increasing frequency for treatment of refractory epilepsy. Acute deep brain macrostimulation intraoperative findings were sparsely published in the literature. We report on our intraoperative macrostimulation findings during thalamic and hippocampal DBS implantation. Eighteen patients were studied. All patients underwent routine pre-operative evaluation that included clinical history, neurological examination, interictal and ictal EEG, high resolution 1.5T MRI and neuropsychological testing. Six patients with temporal lobe epilepsy were submitted to hippocampal DBS (Hip-DBS); 6 patients with focal epilepsy were submitted to anterior thalamic nucleus DBS (AN-DBS) and 6 patients with generalized epilepsy were submitted to centro-median thalamic nucleus DBS (CM-DBS). Age ranged from 9 to 40 years (11 males). All patients were submitted to bilateral quadripolar DBS electrode implantation in a single procedure, under general anesthesia, and intraoperative scalp EEG monitoring. Final electrode's position was checked postoperatively using volumetric CT scanning. Bipolar stimulation using the more proximal and distal electrodes was performed. Final standard stimulation parameters were 6Hz, 4V, 300μs (low frequency range: LF) or 130Hz, 4V, 300μs (high frequency range: HF). Bilateral recruiting response (RR) was obtained after unilateral stimulation in all patients submitted to AN and CM-DBS using LF stimulation. RR was widespread but prevailed over the fronto-temporal region bilaterally, and over the stimulated hemisphere. HF stimulation led to background slowing and a DC shift. The mean voltage for the appearance of RR was 4V (CM) and 3V (AN). CM and AN-DBS did not alter inter-ictal spiking frequency or morphology. RR obtained after LF Hip-DBS was restricted to the stimulated temporal lobe and no contralateral activation was noted. HF stimulation yielded no visually recognizable EEG modification. Mean intensity for initial appearance of RR was 3V. In 5 of the 6 patients submitted to Hip-DBS, an increase in inter-ictal spiking was noted unilaterally immediately after electrode insertion. Intraoperative LF stimulation did not modify temporal lobe spiking; on the other hand, HF was effective in abolishing inter-ictal spiking in 4 of the 6 patients studied. There was no immediate morbidity or mortality in this series. Macrostimulation might be used to confirm that the hardware was working properly. There was no typical RR derived from each studied thalamic nuclei after LF stimulation. On the other hand, absence of such RRs was highly suggestive of hardware malfunction or inadequate targeting. Thalamic-DBS (Th-DBS) RR was always bilateral after unilateral stimulation, although they somehow prevailed over the stimulated hemisphere. Contrary to Th-DBS, Hip-DBS gave rise to localized RR over the ipsolateral temporal neocortex, and absence of this response might very likely be related to inadequate targeting or hardware failure. Increased spiking was seen over temporal neocortex during hippocampal electrode insertion; this might point to the more epileptogenic hippocampal region in each individual patient. We did not notice any intraoperative response difference among patients with temporal lobe epilepsy with or without MTS. The relationship between these intraoperative findings and seizure outcome is not yet clear and should be further evaluated. 2011 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.
Effects of perceived parental attitudes on children's views of smoking.
Ozturk, Candan; Kahraman, Seniha; Bektas, Murat
2013-01-01
The aim of this study was to examine the effects of perceived parental attitudes on children's discernment of cigarettes. The study sample consisted of 250 children attending grades 6, 7 and 8. Data were collected via a socio-demographic survey questionnaire, the Parental Attitude Scale (PAS) and the Decisional Balance Scale (DBS). Data analysis covered percentages, medians, one-way analysis of variance (ANOVA) and post-hoc tests using a statistical package. There were 250 participants; 117 were male, 133 were female. The mean age was 13.1 ± 0.98 for the females and 13.3 ± 0.88 for the males. A statistically significant difference was found in the children's mean scores for 'pros' subscale on the Decisional Balance Scale (DBS) according to perceived parental attitudes (F=3.172, p=0.025). There were no statistically significant differences in the DBS 'cons' subscale scores by perceived parental attitudes. It was determined that while perceived parental attitudes affect children's views on advantages of smoking, they have no effect on children's views on its disadvantages.
Schulz, Geralyn M; Hosey, Lara A; Bradberry, Trent J; Stager, Sheila V; Lee, Li-Ching; Pawha, Rajesh; Lyons, Kelly E; Metman, Leo Verhagen; Braun, Allen R
2012-01-01
Deep brain stimulation (DBS) of the subthalamic nucleus improves the motor symptoms of Parkinson's disease, but may produce a worsening of speech and language performance at rates and amplitudes typically selected in clinical practice. The possibility that these dissociated effects might be modulated by selective stimulation of left and right STN has never been systematically investigated. To address this issue, we analyzed motor, speech and language functions of 12 patients implanted with bilateral stimulators configured for optimal motor responses. Behavioral responses were quantified under four stimulator conditions: bilateral DBS, right-only DBS, left-only DBS and no DBS. Under bilateral and left-only DBS conditions, our results exhibited a significant improvement in motor symptoms but worsening of speech and language. These findings contribute to the growing body of literature demonstrating that bilateral STN DBS compromises speech and language function and suggests that these negative effects may be principally due to left-sided stimulation. These findings may have practical clinical consequences, suggesting that clinicians might optimize motor, speech and language functions by carefully adjusting left- and right-sided stimulation parameters.
Aldridge, Danielle; Theodoros, Deborah; Angwin, Anthony; Vogel, Adam P
2016-12-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is effective in reducing motor symptoms for many individuals with Parkinson's disease (PD). However, STN DBS does not appear to influence speech in the same way, and may result in a variety of negative outcomes for people with PD (PWP). A high degree of inter-individual variability amongst PWP regarding speech outcomes following STN DBS is evident in many studies. Furthermore, speech studies in PWP following STN DBS have employed a wide variety of designs and methodologies, which complicate comparison and interpretation of outcome data amongst studies within this growing body of research. An analysis of published evidence regarding speech outcomes in PWP following STN DBS, according to design and quality, is missing. This systematic review aimed to analyse and coalesce all of the current evidence reported within observational and experimental studies investigating the effects of STN DBS on speech. It will strengthen understanding of the relationship between STN DBS and speech, and inform future research by highlighting methodological limitations of current evidence. Copyright © 2016 Elsevier Ltd. All rights reserved.
DBS Programming: An Evolving Approach for Patients with Parkinson's Disease.
Wagle Shukla, Aparna; Zeilman, Pam; Fernandez, Hubert; Bajwa, Jawad A; Mehanna, Raja
2017-01-01
Deep brain stimulation (DBS) surgery is a well-established therapy for control of motor symptoms in Parkinson's disease. Despite an appropriate targeting and an accurate placement of DBS lead, a thorough and efficient programming is critical for a successful clinical outcome. DBS programming is a time consuming and laborious manual process. The current approach involves use of general guidelines involving determination of the lead type, electrode configuration, impedance check, and battery check. However there are no validated and well-established programming protocols. In this review, we will discuss the current practice and the recent advances in DBS programming including the use of interleaving, fractionated current, directional steering of current, and the use of novel DBS pulses. These technological improvements are focused on achieving a more efficient control of clinical symptoms with the least possible side effects. Other promising advances include the introduction of computer guided programming which will likely impact the efficiency of programming for the clinicians and the possibility of remote Internet based programming which will improve access to DBS care for the patients.
Luoma, Jarkko; Pekkonen, Eero; Airaksinen, Katja; Helle, Liisa; Nurminen, Jussi; Taulu, Samu; Mäkelä, Jyrki P
2018-06-22
Advanced Parkinson's disease (PD) is characterized by an excessive oscillatory beta band activity in the subthalamic nucleus (STN). Deep brain stimulation (DBS) of STN alleviates motor symptoms in PD and suppresses the STN beta band activity. The effect of DBS on cortical sensorimotor activity is more ambiguous; both increases and decreases of beta band activity have been reported. Non-invasive studies with simultaneous DBS are problematic due to DBS-induced artifacts. We recorded magnetoencephalography (MEG) from 16 advanced PD patients with and without STN DBS during rest and wrist extension. The strong magnetic artifacts related to stimulation were removed by temporal signal space separation. MEG oscillatory activity at 5-25 Hz was suppressed during DBS in a widespread frontoparietal region, including the sensorimotor cortex identified by the cortico-muscular coherence. The strength of suppression did not correlate with clinical improvement. Our results indicate that alpha and beta band oscillations are suppressed at the frontoparietal cortex by STN DBS in PD. Copyright © 2018. Published by Elsevier B.V.
DBS Programming: An Evolving Approach for Patients with Parkinson's Disease
Zeilman, Pam; Fernandez, Hubert; Bajwa, Jawad A.
2017-01-01
Deep brain stimulation (DBS) surgery is a well-established therapy for control of motor symptoms in Parkinson's disease. Despite an appropriate targeting and an accurate placement of DBS lead, a thorough and efficient programming is critical for a successful clinical outcome. DBS programming is a time consuming and laborious manual process. The current approach involves use of general guidelines involving determination of the lead type, electrode configuration, impedance check, and battery check. However there are no validated and well-established programming protocols. In this review, we will discuss the current practice and the recent advances in DBS programming including the use of interleaving, fractionated current, directional steering of current, and the use of novel DBS pulses. These technological improvements are focused on achieving a more efficient control of clinical symptoms with the least possible side effects. Other promising advances include the introduction of computer guided programming which will likely impact the efficiency of programming for the clinicians and the possibility of remote Internet based programming which will improve access to DBS care for the patients. PMID:29147598
Peisker, Canan B; Schüller, Thomas; Peters, Jan; Wagner, Ben J; Schilbach, Leonhard; Müller, Ulf J; Visser-Vandewalle, Veerle; Kuhn, Jens
2018-01-27
Deep brain stimulation (DBS) of the nucleus accumbens (NAc) shows first promising results in patients with severe substance use disorder (SUD), a patient group known to have deficits in self-control. One facet of self-control is the ability to forego smaller sooner rewards in favor of larger later rewards (delay discounting, DD). The NAc has been suggested to integrate motivational information to guide behavior while the consequences of NAc-DBS on DD are unknown. To this end, nine patients with SUD performed a DD task with DBS on and after a 24 h DBS off period. Furthermore, 18 healthy controls were measured to assess possible alterations in DD in patients with SUD. Our findings implicate that DD was not significantly modulated by NAc-DBS and also that patients with SUD did not differ from healthy controls. While null results must be interpreted with caution, the commonly observed association of impaired DD in SUD might suggest a long-term effect of NAc-DBS that was not sufficiently modulated by a 24 h DBS off period.
Fluid flow simulation and permeability computation in deformed porous carbonate grainstones
NASA Astrophysics Data System (ADS)
Zambrano, Miller; Tondi, Emanuele; Mancini, Lucia; Lanzafame, Gabriele; Trias, F. Xavier; Arzilli, Fabio; Materazzi, Marco; Torrieri, Stefano
2018-05-01
In deformed porous carbonates, the architecture of the pore network may be modified by deformation or diagenetic processes altering the permeability with respect to the pristine rock. The effects of the pore texture and morphology on permeability in porous rocks have been widely investigated due to the importance during the evaluation of geofluid reservoirs. In this study, these effects are assessed by combining synchrotron X-ray computed microtomography (SR micro-CT) and computational fluid dynamics. The studied samples pertain to deformed porous carbonate grainstones highly affected by deformation bands (DBs) exposed in Northwestern Sicily and Abruzzo regions, Italy. The high-resolution SR micro-CT images of the samples, acquired at the SYRMEP beamline of the Elettra - Sincrotrone Trieste laboratory (Italy), were used for simulating a pressure-driven flow by using the lattice-Boltzmann method (LBM). For the experiments, a multiple relaxation time (MRT) model with the D3Q19 scheme was used to avoid viscosity-dependent results of permeability. The permeability was calculated using Darcy's law once steady conditions were reached. After the simulations, the pore-network properties (effective porosity, specific surface area, and geometrical tortuosity) were calculated using 3D images of the velocity fields. These images were segmented considering a velocity threshold value higher than zero. The study showed that DBs may generate significant heterogeneity and anisotropy of the permeability of the evaluated rock samples. Cataclasis and cementation process taking place within the DBs reduce the effective porosity and therefore the permeability. Contrary to this, pressure dissolution and faulting may generate connected channels which contribute to the permeability only parallel to the DB.
McCandless, Shawn E; Chandrasekar, Ram; Linard, Sharon; Kikano, Sandra; Rice, Lorrie
2013-01-01
Newborn screening (NBS) for medium chain acyl-CoA dehydrogenase deficiency (MCADD), one of the most common disorders identified, uses measurement of octanoylcarnitine (C8) from dried blood spots. In the state of Ohio, as in many places, primary care providers, with or without consultation from a metabolic specialist, may perform "confirmatory testing", with the final diagnostic decision returned to the state. Confirmatory testing may involve measurement of metabolites, enzyme analysis, mutation screening, or sequencing. We now report sequencing results for infants said to have "false positive" NBS results for MCAD deficiency, or who died before confirmatory testing could be performed. Dried blood spots (DBS) were obtained from all 18 available NBS cards identified as "false positive" by NBS for the 3 year period after screening began in Ohio in 2003 (N=20, thus 2 had no DBS available), and from all 6 infants with abnormal screens who died before confirmatory testing could be obtained. DNA extracted from DBS was screened for the common c.985A>G mutation in exon 11 of the ACADM gene, using a specific restriction digest method, followed by sequencing of the 12 exons, intron-exon junctions, and several hundred base pairs of the 5' untranslated region. The NBS cut-off value for C8 used was 0.7 μmol/L. Sequencing of ACADM in six neonates with elevated C8 on NBS who died before confirmatory testing was obtained did not identify any significant variants in the coding region of the gene, suggesting that MCADD was not a contributing factor in these deaths. The mean C8 for the 18 surviving infants labeled as "False Positives" was 0.90 (95%CI 0.77-1.15), much lower than the mean value for confirmed cases. Ten of the 18 were premature births weighing <1200 g, the rest were normal sized and full term. Eight infants, mostly full term with appropriate birth weight, were heterozygous for the common c.985A>G mutation; one of those also has a novel sequence change identified in exon 9 that predicts a PRO to LEU change at residue 258 of the protein. Both the phase and any possible clinical significance of the variant are unknown, but several lines of evidence suggest that it could lead to protein malfunction. That child had an NBS C8 of 2.2, more than double the mean for the False Positive group. Unfortunately, the study design did not provide clinical outcome data, but the child is not known to have presented clinically by age 7 years. These results suggest that sequencing of ACADM from dried blood spots can be one useful follow-up tool to provide accurate genetic counseling in the situation of an infant with elevated C8 on NBS who dies before confirmatory testing is obtained. Of surviving neonates, there appear to be two populations of infants with false positive NBS C8 values: 1) term AGA infants who are heterozygous for the common c.985A>G mutation, and, 2) premature infants, regardless of carrier status. The finding of two sequence variants in an infant reported to the state as not affected suggests the possibility that some infants with two mutations may be reported as normal at follow-up. State registries may wish to consider asking that metabolic specialists, who are most familiar with the variability of these rare disorders, be involved in the final diagnostic evaluation. Finally, providers may wish to consider ACADM sequencing, or other diagnostic testing, as part of the confirmatory evaluation for infants with NBS C8 concentrations that are significantly above the cut-off value, even if plasma and urine metabolites are not strikingly increased. Copyright © 2012 Elsevier Inc. All rights reserved.
Wondafrash, Beyene; Hiko, Desta
2016-01-01
Infants and children living with HIV receive antiretroviral treatment often late, are exposed to opportunistic infection and quickly develop AIDS. Few hospitals are providing ART service after Dried Blood Spot (DBS)test.The objective of this study is to assess the status of infants and children linked to ART. Descriptive cross-sectional study was conducted in hospitals. Data of 138 infants and children exposed to HIV were collected from registration books and data bases from 2009 to 2011. Data were analyzed using SPSS version 16. Chi-squared test and p-value were computed. In-depth interviews were conducted with key informants. Ninety-eight (71%) infants and children exposed to HIV were diagnosed for HIV infection of which 68(69.4%) initiated ART. Twenty four (35.3%) initiated ART one month after HIV screening results. Thirty-three (50.0%) and 23(35.3%) infants and children dropped from and adhered to ART respectively. Eleven (16.2%) of them who initiated ART died within the study period. HIV infection status (p-value=0.003), dropping from ART (p-value=0.002) and death after ART initiation (p-value=0.010) showed significance with mothers' PMTCT service status. Seven in ten HIV-exposed infants and children were diagnosed with HIV, and almost all of them initiated ART. The overall turnaround time was 10 days. Based up on mothers' PMTCT service status, there was a significant difference among HIV-exposed infants and children in acquiring HIV infection from mothers during pregnancy (p-value=0.003) and dropping from ART (p-value=0.010). There were challenges in sample collection and transportation. Early HIV screening during pregnancy and PMTCT service should be strengthened.
Barbaro, Michela; Ohlsson, Annika; Borte, Stephan; Jonsson, Susanne; Zetterström, Rolf H; King, Jovanka; Winiarski, Jacek; von Döbeln, Ulrika; Hammarström, Lennart
2017-01-01
Newborn screening for severe primary immunodeficiencies (PID), characterized by T and/or B cell lymphopenia, was carried out in a pilot program in the Stockholm County, Sweden, over a 2-year period, encompassing 58,834 children. T cell receptor excision circles (TREC) and kappa-deleting recombination excision circles (KREC) were measured simultaneously using a quantitative PCR-based method on DNA extracted from dried blood spots (DBS), with beta-actin serving as a quality control for DNA quantity. Diagnostic cutoff levels enabling identification of newborns with milder and reversible T and/or B cell lymphopenia were also evaluated. Sixty-four children were recalled for follow-up due to low TREC and/or KREC levels, and three patients with immunodeficiency (Artemis-SCID, ATM, and an as yet unclassified T cell lymphopenia/hypogammaglobulinemia) were identified. Of the positive samples, 24 were associated with prematurity. Thirteen children born to mothers treated with immunosuppressive agents during pregnancy (azathioprine (n = 9), mercaptopurine (n = 1), azathioprine and tacrolimus (n = 3)) showed low KREC levels at birth, which spontaneously normalized. Twenty-nine newborns had no apparent cause identified for their abnormal results, but normalized with time. Children with trisomy 21 (n = 43) showed a lower median number of both TREC (104 vs. 174 copies/μL blood) and KREC (45 vs. 100 copies/3.2 mm blood spot), but only one, born prematurely, fell below the cutoff level. Two children diagnosed with DiGeorge syndrome were found to have low TREC levels, but these were still above the cutoff level. This is the first large-scale screening study with a simultaneous detection of both TREC and KREC, allowing identification of newborns with both T and B cell defects.
Neuroimaging and cognitive changes during déjà vu.
Kovacs, Norbert; Auer, Tibor; Balas, Istvan; Karadi, Kazmer; Zambo, Katalin; Schwarcz, Attila; Klivenyi, Peter; Jokeit, Hennric; Horvath, Krisztina; Nagy, Ferenc; Janszky, Jozsef
2009-01-01
The cause or the physiological role of déjà vu (DV) in healthy people is unknown. The pathophysiology of DV-type epileptic aura is also unresolved. Here we describe a 22-year-old woman treated with deep brain stimulation (DBS) of the left internal globus pallidus for hemidystonia. At certain stimulation settings, DBS elicited reproducible episodes of DV. Neuropsychological tests and single-photon-emission computed tomography (SPECT) were performed during DBS-evoked DV and during normal DBS stimulation without DV. SPECT during DBS-evoked DV revealed hyperperfusion of the right (contralateral to the electrode) hippocampus and other limbic structures. Neuropsychological examinations performed during several evoked DV episodes revealed disturbances in nonverbal memory. Our results confirm the role of mesiotemporal structures in the pathogenesis of DV. We hypothesize that individual neuroanatomy and disturbances in gamma oscillations or in the dopaminergic system played a role in DBS-elicited DV in our patient.
Grassi, Giacomo; Figee, Martijn; Ooms, Pieter; Righi, Lorenzo; Nakamae, Takashi; Pallanti, Stefano; Schuurman, Rick; Denys, Damiaan
2018-06-04
Impulsivity and impaired decision-making have been proposed as obsessive-compulsive disorder (OCD) endophenotypes, running in OCD and their healthy relatives independently of symptom severity and medication status. Deep brain stimulation (DBS) targeting the ventral limb of the internal capsule (vALIC) and the nucleus accumbens (Nacc) is an effective treatment strategy for treatment-refractory OCD. The effectiveness of vALIC-DBS for OCD has been linked to its effects on a frontostriatal network that is also implicated in reward, impulse control, and decision-making. While vALIC-DBS has been shown to restore reward dysfunction in OCD patients, little is known about the effects of vALIC-DBS on impulsivity and decision-making. The aim of the study was to compare cognitive impulsivity and decision-making between OCD patients undergoing effective vALIC-DBS or treatment as usual (TAU), and healthy controls. We used decision-making performances under ambiguity on the Iowa Gambling Task and reflection impulsivity on the Beads Task to compare 20 OCD patients effectively treated with vALIC-DBS, 40 matched OCD patients undergoing effective TAU (medication and/or cognitive behavioural therapy), and 40 healthy subjects. Effective treatment was defined as at least 35% improvement of OCD symptoms. OCD patients, irrespective of treatment modality (DBS or TAU), showed increased reflection impulsivity and impaired decision-making compared to healthy controls. No differences were observed between OCD patients treated with DBS or TAU. OCD patients effectively treated with vALIC-DBS or TAU display increased reflection impulsivity and impaired decision-making independent of the type of treatment.
Bell, Emily; Maxwell, Bruce; McAndrews, Mary Pat; Sadikot, Abbas; Racine, Eric
2011-12-01
Deep brain stimulation (DBS) is an approved neurosurgical intervention for motor disorders such as Parkinson disease. The emergence of psychiatric uses for DBS combined with the fact that it is an invasive and expensive procedure creates important ethical and social challenges in the delivery of care that need further examination. We endeavored to examine health care provider perspectives on ethical and social challenges encountered in DBS. Health care providers working in Canadian DBS surgery programs participated in a semistructured interview to identify and characterize ethical and social challenges of DBS. A content analysis of the interviews was conducted. Several key ethical issues, such as patient screening and resource allocation, were identified by members of neurosurgical teams. Providers described challenges in selecting patients for DBS on the basis of unclear evidence-based guidance regarding behavioral issues or cognitive criteria. Varied contexts of resource allocation, including some very challenging schemas, were also reported. In addition, the management of patients in the community was highlighted as a source of ethical and clinical complexity, given the need for coordinated long-term care. This study provides insights into the complexity of ethical challenges that providers face in the use of DBS across different neurosurgical centers. We propose actions for health care providers for the long-term care and postoperative monitoring of patients with DBS. More data on patient perspectives in DBS would complement the understanding of key challenges, as well as contribute to best practices, for patient selection, management, and resource allocation. Copyright © 2011 Elsevier Inc. All rights reserved.
Madjd, Ameneh; Taylor, Moira A; Delavari, Alireza; Malekzadeh, Reza; Macdonald, Ian A; Farshchi, Hamid R
2015-12-01
Obese people believe that drinking diet beverages (DBs) may be a simple strategy to achieve weight loss. However, nutritionists advise drinking water when attempting to lose weight. It is unclear how important drinking water instead of DBs is during a weight-loss program. In this study, we compared the effect on weight loss of either replacing DBs with water or continuing to consume DBs in adults during a 24-wk weight-loss program. Overweight and obese women [n = 89; body mass index (BMI; in kg/m(2)): 27-40; age: 18-50 y] who usually consumed DBs in their diet were asked to either substitute water for DBs (water group) or continue drinking DBs 5 times/wk after their lunch for 24 wk (DB group) while on a weight-loss program. Sixty-two participants (71%) completed the trial (32 in the DB group, 30 in the water group). Baseline variables were not statistically significantly different between groups. A statistically significant reduction in anthropometric measurements and statistically significant improvements in cardiometabolic risk characteristics were observed over 24 wk in both groups. Compared with the DB group, the water group had a greater decrease in weight (mean ± SD: water: -8.8 ± 1.9 kg; DBs: -7.6 ± 2.1 kg; P = 0.015, time × group), fasting insulin (mean ± SD: water: -2.84 ± 0.77 mU/L; DBs: -1.78 ± 1.25 mU/L, P < 0.001), homeostasis model assessment of insulin resistance (mean ± SD: water: -0.097 ± 0.049; DBs: -0.057 ± 0.042, P < 0.001), and 2-h postprandial glucose (mean ± SD: water: -1.02 ± 0.25 mmol/L; DBs: -0.72 ± 0.27 mmol/L; P < 0.001) over the 24 wk. However, there was no significant time × group interaction for waist circumference, fasting plasma glucose, and lipid profiles within both groups over 24 wk. Replacement of DBs with water after the main meal may lead to greater weight reduction during a weight-loss program. It may also offer clinical benefits to improve insulin resistance. This trial was registered at www.irct.ir/ as IRCT201402177754N5. © 2015 American Society for Nutrition.
Wichmann, Thomas; DeLong, Mahlon R
2016-04-01
Deep brain stimulation (DBS) is highly effective for both hypo- and hyperkinetic movement disorders of basal ganglia origin. The clinical use of DBS is, in part, empiric, based on the experience with prior surgical ablative therapies for these disorders, and, in part, driven by scientific discoveries made decades ago. In this review, we consider anatomical and functional concepts of the basal ganglia relevant to our understanding of DBS mechanisms, as well as our current understanding of the pathophysiology of two of the most commonly DBS-treated conditions, Parkinson's disease and dystonia. Finally, we discuss the proposed mechanism(s) of action of DBS in restoring function in patients with movement disorders. The signs and symptoms of the various disorders appear to result from signature disordered activity in the basal ganglia output, which disrupts the activity in thalamocortical and brainstem networks. The available evidence suggests that the effects of DBS are strongly dependent on targeting sensorimotor portions of specific nodes of the basal ganglia-thalamocortical motor circuit, that is, the subthalamic nucleus and the internal segment of the globus pallidus. There is little evidence to suggest that DBS in patients with movement disorders restores normal basal ganglia functions (e.g., their role in movement or reinforcement learning). Instead, it appears that high-frequency DBS replaces the abnormal basal ganglia output with a more tolerable pattern, which helps to restore the functionality of downstream networks.
Hacker, Mallory L.; Turchan, Maxim; Molinari, Anna L.; Currie, Amanda D.
2017-01-01
Previous studies suggest that deep brain stimulation of the subthalamic nucleus (STN-DBS) for Parkinson's disease (PD) leads to weight gain. This study analyzes changes in body mass index (BMI) in 29 subjects from a prospective, single-blind trial of DBS in early stage PD (age 50–75, Hoehn & Yahr stage II off medication, treated with antiparkinsonian medications for ≥6 months but <4 years, and without a history of motor fluctuations, dyskinesias, or dementia). Subjects were randomized to DBS plus optimal drug therapy (DBS+ODT; n = 15) or ODT (n = 14) and followed for 24 months. Weight and height were recorded at baseline and each follow-up visit and used to calculate BMI. BMIs were compared within and between groups using nonparametric t-tests. Mean BMI at baseline was 29.7 in the ODT group and 32.3 in the DBS+ODT group (p > 0.05). BMI change over two years was not different between the groups (p = 0.62, ODT = −0.89; DBS+ODT = −0.17). This study suggests that STN-DBS is not associated with weight gain in subjects with early stage PD. This finding will be tested in an upcoming FDA-approved phase III multicenter, randomized, double-blind, placebo-controlled, pivotal clinical trial evaluating DBS in early stage PD (ClinicalTrials.gov identifier NCT00282152). PMID:28676842
Millan, Sarah H; Hacker, Mallory L; Turchan, Maxim; Molinari, Anna L; Currie, Amanda D; Charles, David
2017-01-01
Previous studies suggest that deep brain stimulation of the subthalamic nucleus (STN-DBS) for Parkinson's disease (PD) leads to weight gain. This study analyzes changes in body mass index (BMI) in 29 subjects from a prospective, single-blind trial of DBS in early stage PD (age 50-75, Hoehn & Yahr stage II off medication, treated with antiparkinsonian medications for ≥6 months but <4 years, and without a history of motor fluctuations, dyskinesias, or dementia). Subjects were randomized to DBS plus optimal drug therapy (DBS+ODT; n = 15) or ODT ( n = 14) and followed for 24 months. Weight and height were recorded at baseline and each follow-up visit and used to calculate BMI. BMIs were compared within and between groups using nonparametric t -tests. Mean BMI at baseline was 29.7 in the ODT group and 32.3 in the DBS+ODT group ( p > 0.05). BMI change over two years was not different between the groups ( p = 0.62, ODT = -0.89; DBS+ODT = -0.17). This study suggests that STN-DBS is not associated with weight gain in subjects with early stage PD. This finding will be tested in an upcoming FDA-approved phase III multicenter, randomized, double-blind, placebo-controlled, pivotal clinical trial evaluating DBS in early stage PD (ClinicalTrials.gov identifier NCT00282152).
Hescham, Sarah; Temel, Yasin; Schipper, Sandra; Lagiere, Mélanie; Schönfeld, Lisa-Maria; Blokland, Arjan; Jahanshahi, Ali
2017-03-01
Deep brain stimulation (DBS) is an established symptomatic treatment modality for movement disorders and constitutes an emerging therapeutic approach for the treatment of memory impairment. In line with this, fornix DBS has shown to ameliorate cognitive decline associated with dementia. Nonetheless, mechanisms mediating clinical effects in demented patients or patients with other neurological disorders are largely unknown. There is evidence that DBS is able to modulate neurophysiological activity in targeted brain regions. We therefore hypothesized that DBS might be able to influence cognitive function via activity-dependent regulation of hippocampal neurogenesis. Using stimulation parameters, which were validated to restore memory loss in a previous behavioral study, we here assessed long-term effects of fornix DBS. To do so, we injected the thymidine analog, 5-bromo-2'-deoxyuridine (BrdU), after DBS and perfused the animals 6.5 weeks later. A week prior to perfusion, memory performance was assessed in the water maze. We found that acute stimulation of the fornix improved spatial memory performance in the water maze when the probe trial was performed 1 h after the last training session. However, no evidence for stimulation-induced neurogenesis was found in fornix DBS rats when compared to sham. Our results suggest that fornix DBS improves memory functions independent of hippocampal neurogenesis, possibly through other mechanisms such as synaptic plasticity and acute neurotransmitter release.
Strowd, Roy E; Herco, Maja; Passmore-Griffin, Leah; Avery, Bradley; Haq, Ihtsham; Tatter, Stephen B; Tate, Jessica; Siddiqui, Mustafa S
2016-01-01
To evaluate whether weight change in patients with Parkinson's disease (PD) is different in those undergoing deep brain stimulation (DBS) of the subthalamic nucleus (STN) compared to those not undergoing DBS. A retrospective case-control study was performed in PD patients who had undergone STN DBS (cases) compared to matched PD patients without DBS (controls). Demographic and clinical data including Unified Parkinson's Disease Rating Scale (UPDRS) motor scores were collected. Repeated measures mixed model regression was used to identify variables associated with weight gain. Thirty-five cases and 34 controls were identified. Baseline age, gender, diagnosis and weight were similar. Duration of diagnosis was longer in cases (6.3 vs 4.9 years, p=0.0015). At 21.3 months, cases gained 2.9 kg (+4.65%) while controls lost 1.8 kg (-3.05%, p<0.02). Postoperative UPDRS motor scores improved by 49% indicating surgical efficacy. Only younger age (p=0.0002) and DBS (p=0.008) were significantly associated with weight gain. In this case-control study, PD patients undergoing STN DBS experienced post-operative weight gain that was significantly different from the weight loss observed in non-DBS PD controls. Patients, especially overweight individuals, should be informed that STN DBS can result in weight gain. Copyright © 2015 Elsevier B.V. All rights reserved.
Nozaki, Takao; Sugiyama, Kenji; Yagi, Shunsuke; Yoshikawa, Etsuji; Kanno, Toshihiko; Asakawa, Tetsuya; Ito, Tae; Terada, Tatsuhiro; Namba, Hiroki; Ouchi, Yasuomi
2013-03-01
To elucidate the dynamic effects of deep brain stimulation (DBS) in the subthalamic nucleus (STN) during activity on the dopaminergic system, 12 PD patients who had STN-DBS operations at least 1 month prior, underwent two positron emission tomography scans during right-foot movement in DBS-off and DBS-on conditions. To quantify motor performance changes, the motion speed and mobility angle of the foot at the ankle were measured twice. Estimations of the binding potential of [(11)C]raclopride (BP(ND)) were based on the Logan plot method. Significant motor recovery was found in the DBS-on condition. The STN-DBS during exercise significantly reduced the [(11)C]raclopride BP(ND) in the caudate and the nucleus accumbens (NA), but not in the dorsal or ventral putamen. The magnitude of dopamine release in the NA correlated negatively with the magnitude of motor load, indicating that STN-DBS facilitated motor behavior more smoothly and at less expense to dopamine neurons in the region. The lack of dopamine release in the putamen and the significant dopamine release in the ventromedial striatum by STN-DBS during exercise indicated dopaminergic activation occurring in the motivational circuit during action, suggesting a compensatory functional activation of the motor loop from the nonmotor to the motor loop system.
Südmeyer, M; Volkmann, J; Wojtecki, L; Deuschl, G; Schnitzler, A; Möller, B
2012-04-01
The aim of this questionnaire-based study was to determine the decision-making motives from Parkinson's patients and their family members for deep brain stimulation (DBS), which are crucial for the attitude towards this therapy and which should be considered during the clinical interview. The questionnaire was sent out nationwide to members of the German Parkinson Association. Patient and family specific data as well as information sources, doubts and expectations with respect to DBS were assessed. A total of 582 patients and 476 family members answered the questionnaire, revealing that 96% of the patients and 91% of the family members already possessed information regarding DBS. While a large proportion of interviewees had specific expectations concerning DBS, more than two thirds expressed concerns regarding DBS; the most frequent with respect to intraoperative complications and stimulation-induced worsening of symptoms. The quantity of realistic patients and family expectations significantly correlated with a positive evaluation of DBS and doubts as well as unrealistic expectations of family members correlated with a negative attitude towards the operation. The findings suggest that patients and their relatives organized in support groups indeed possess detailed information regarding DBS. However, for the acceptance of the treatment a timely elucidation about DBS as well as responding to the individual concerns by the consulting physician is essential.
Austin, Allana; Lin, Jean-Pierre; Selway, Richard; Ashkan, Keyoumars; Owen, Tamsin
2017-01-01
Dystonia is characterised by involuntary movements and postures. Deep Brain Stimulation (DBS) is effective in reducing dystonic symptoms in primary dystonia in childhood and to lesser extent in secondary dystonia. How families and children decide to choose DBS surgery has never been explored. To explore parental decision-making for DBS in paediatric secondary dystonia. Data was gathered using semi-structured interviews with eight parents of children with secondary dystonia who had undergone DBS. Interviews were analysed using Interpretative Phenomenological Analysis. For all parents the decision was viewed as significant, with life altering consequences for the child. These results suggested that parents were motivated by a hope for a better life and parental duty. This was weighed against consideration of risks, what the child had to lose, and uncertainty of DBS outcome. Decisions were also influenced by the perspectives of their child and professionals. The decision to undergo DBS was an ongoing process for parents, who ultimately were struggling in the face of uncertainty whilst trying to do their best as parents for their children. These findings have important clinical implications given the growing referrals for consideration of DBS childhood dystonia, and highlights the importance of further quantitative research to fully establish the efficacy of DBS in secondary dystonia to enhance informed decision-making. Copyright © 2016. Published by Elsevier Ltd.
Peppe, Antonella; Pierantozzi, Mariangela; Baiamonte, Valentina; Moschella, Vincenzo; Caltagirone, Carlo; Stanzione, Paolo; Stefani, Alessandro
2012-12-01
Sleep disorders are frequent non-motor symptoms in Parkinson disease (PD), probably due to multifactorial pathogeneses including disease progression, dopaminergic drugs, or concomitant illness. In recent years, the pedunculopontine tegmental (PPTg) nucleus has been considered a surgical target for deep brain stimulation (DBS) in advanced PD patients. As it is involved in controlling the sleep-wake cycle, we investigated the long-lasting effects of PPTg-DBS on the sleep of five PD patients implanted in both the PPTg and the subthalamic nucleus (STN) by rating two subjective clinical scales for sleep: the Parkinson's Disease Sleep Scale (PDSS), and the Epworth Sleepiness Scale (ESS). Sleep scales were administered a week before surgery (T0), three months after DBS (T1), and one year later (T2). In this study, STN-DBS was kept constantly in ON, and three different patterns of PPTg-DBS were investigated: STN-ON (PPTg switched off); PPTg-ON (PPTg stimulated 24 h/day); PPTg-cycle (PPTg stimulated only at night). In post-surgery follow-up, PD patients reported a marked improvement of sleep quality in all DBS conditions. In particular, stimulation of the PPTg nucleus produced not only a remarkable long-term improvement of nighttime sleep, but unlike STN-DBS, also produced significant amelioration of daytime sleepiness. Our study suggests that PPTg-DBS plays an important role in reorganizing regular sleep in PD patients.
The impact of Parkinson's disease and subthalamic deep brain stimulation on reward processing.
Evens, Ricarda; Stankevich, Yuliya; Dshemuchadse, Maja; Storch, Alexander; Wolz, Martin; Reichmann, Heinz; Schlaepfer, Thomas E; Goschke, Thomas; Lueken, Ulrike
2015-08-01
Due to its position in cortico-subthalamic and cortico-striatal pathways, the subthalamic nucleus (STN) is considered to play a crucial role not only in motor, but also in cognitive and motivational functions. In the present study we aimed to characterize how different aspects of reward processing are affected by disease and deep brain stimulation of the STN (DBS-STN) in patients with idiopathic Parkinson's disease (PD). We compared 33 PD patients treated with DBS-STN under best medical treatment (DBS-on, medication-on) to 33 PD patients without DBS, but optimized pharmacological treatment and 34 age-matched healthy controls. We then investigated DBS-STN effects using a postoperative stimulation-on/ -off design. The task set included a delay discounting task, a task to assess changes in incentive salience attribution, and the Iowa Gambling Task. The presence of PD was associated with increased incentive salience attribution and devaluation of delayed rewards. Acute DBS-STN increased risky choices in the Iowa Gambling Task under DBS-on condition, but did not further affect incentive salience attribution or the evaluation of delayed rewards. Findings indicate that acute DBS-STN affects specific aspects of reward processing, including the weighting of gains and losses, while larger-scale effects of disease or medication are predominant in others reward-related functions. Copyright © 2015 Elsevier Ltd. All rights reserved.
Noreik, M; Kuhn, J; Hardenacke, K; Lenartz, D; Bauer, A; Bührle, C P; Häussermann, P; Hellmich, M; Klosterkötter, J; Wiltfang, J; Maarouf, M; Freund, H-J; Visser-Vandewalle, V; Sturm, V; Schulz, R-J
2015-10-01
The progression of Alzheimer's disease (AD) is associated with impaired nutritional status. New methods, such as deep brain stimulation (DBS), are currently being tested to decrease the progression of AD. DBS is an approved method in the treatment of Parkinson's disease, and its suitability for the treatment of AD patients is currently under experimental investigation. To evaluate the advantages and disadvantages of this new treatment, it is important to assess potential side effects of DBS regarding the nucleus basalis of Meynert; this new treatment is thought to positively affect cognition and might counteract the deterioration of nutritional status and progressive weight loss observed in AD. This study aims to assess the nutritional status of patients with AD before receiving DBS of the nucleus basalis of Meynert and after 1 year, and to analyze potential associations between changes in cognition and nutritional status. A 1-year phase I proof-of-concept study. The Department of Psychiatry and Psychotherapy at the University of Cologne. We assessed a consecutive sample of patients with mild to moderate AD (n=6) who fulfilled the inclusion criteria and provided written informed consent. Bilateral low-frequency DBS of the nucleus basalis of Meynert. Nutritional status was assessed using a modified Mini Nutritional Assessment, bioelectrical impedance analysis, a completed 3-day food diary, and analysis of serum levels of vitamin B12 and folate. With a normal body mass index (BMI) at baseline (mean 23.75 kg/m²) and after 1 year (mean 24.59 kg/m²), all but one patient gained body weight during the period of the pilot study (mean 2.38 kg, 3.81% of body weight). This was reflected in a mainly stable or improved body composition, assessed by bioelectrical impedance analysis, in five of the six patients. Mean energy intake increased from 1534 kcal/day (min 1037, max 2370) at baseline to 1736 kcal/day (min 1010, max 2663) after 1 year, leading to the improved fulfillment of energy needs in four patients. The only nutritional factors that were associated with changes in cognition were vitamin B12 level at baseline (Spearman's rho = 0.943, p = 0.005) and changes in vitamin B12 level (Spearman's rho = -0.829, p = 0.042). Patients with AD that received DBS of the nucleus basalis of Meynert demonstrated a mainly stable nutritional status within a 1-year period. Whether DBS is causative regarding these observations must be investigated in additional studies.
Liu, Yi; Li, Weina; Tan, Changhong; Liu, Xi; Wang, Xin; Gui, Yuejiang; Qin, Lu; Deng, Fen; Hu, Changlin; Chen, Lifen
2014-09-01
Deep brain stimulation (DBS) is the surgical procedure of choice for patients with advanced Parkinson disease (PD). The globus pallidus internus (GPi) and the subthalamic nucleus (STN) are commonly targeted by this procedure. The purpose of this meta-analysis was to compare the efficacy of DBS in each region. MEDLINE/PubMed, EMBASE, Web of Knowledge, and the Cochrane Library were searched for English-language studies published before April 2013. of studies investigating the efficacy and clinical outcomes of DBS of the GPi and STN for PD were analyzed. Six eligible trials containing a total of 563 patients were included in the analysis. Deep brain stimulation of the GPi or STN equally improved motor function, measured by the Unified Parkinson's Disease Rating Scale Section III (UPDRSIII) (motor section, for patients in on- and off-medication phases), within 1 year postsurgery. The change score for the on-medication phase was 0.68 (95% CI - 2.12 to 3.47, p > 0.05; 5 studies, 518 patients) and for the off-medication phase was 1.83 (95% CI - 3.12 to 6.77, p > 0.05; 5 studies, 518 patients). The UPDRS Section II (activities of daily living) scores for patients on medication improved equally in both DBS groups (p = 0.97). STN DBS allowed medication dosages to be reduced more than GPi DBS (95% CI 129.27-316.64, p < 0.00001; 5 studies, 540 patients). Psychiatric symptoms, measured by Beck Depression Inventory, 2nd edition scores, showed greater improvement from baseline after GPi DBS than after STN DBS (standardized mean difference -2.28, 95% CI -3.73 to -0.84, p = 0.002; 3 studies, 382 patients). GPi and STN DBS improve motor function and activities of daily living for PD patients. Differences in therapeutic efficacy for PD were not observed between the 2 procedures. STN DBS allowed greater reduction in medication for patients, whereas GPi DBS provided greater relief from psychiatric symptoms. An understanding of other symptomatic aspects of targeting each region and long-term observations on therapeutic effects are needed.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Milestones. (a) Licensees of geostationary orbit satellite systems other than DBS and DARS satellite systems.... (b) Licensees of non-geostationary orbit satellite systems other than DBS and DARS satellite systems... both non-geostationary orbit satellites and geostationary orbit satellites, other than DBS and DARS...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Milestones. (a) Licensees of geostationary orbit satellite systems other than DBS and DARS satellite systems.... (b) Licensees of non-geostationary orbit satellite systems other than DBS and DARS satellite systems... both non-geostationary orbit satellites and geostationary orbit satellites, other than DBS and DARS...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Milestones. (a) Licensees of geostationary orbit satellite systems other than DBS and DARS satellite systems.... (b) Licensees of non-geostationary orbit satellite systems other than DBS and DARS satellite systems... both non-geostationary orbit satellites and geostationary orbit satellites, other than DBS and DARS...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Milestones. (a) Licensees of geostationary orbit satellite systems other than DBS and DARS satellite systems.... (b) Licensees of non-geostationary orbit satellite systems other than DBS and DARS satellite systems... both non-geostationary orbit satellites and geostationary orbit satellites, other than DBS and DARS...
Elgebaly, Ahmed; Elfil, Mohamed; Attia, Attia; Magdy, Mayar; Negida, Ahmed
2018-02-01
Studies comparing subthalamus (STN) and globus pallidus internus (GPi) deep brain stimulation (DBS) for the management of Parkinson's disease in terms of neuropsychological performance are scarce and heterogeneous. Therefore, we performed a systematic review and metaanalysis to compare neuropsychological outcomes following STN DBS versus GPi DBS. A computer literature search of PubMed, the Web of Science, and Cochrane Central was conducted. Records were screened for eligible studies, and data were extracted and synthesized using Review Manager (v. 5.3 for Windows). Seven studies were included in the qualitative synthesis. Of them, four randomized controlled trials (n=345 patients) were pooled in the metaanalysis models. The standardized mean difference (SMD) of change in the Stroop color-naming test favored the GPi DBS group (SMD=-0.31, p=0.009). However, other neuropsychological outcomes did not favor either of the two groups (Stroop word-reading: SMD=-0.21, p=0.08; the Wechsler Adult Intelligence Scale (WAIS) digits forward: SMD=0.08, p=0.47; Trail Making Test Part A: SMD=-0.05, p=0.65; WAIS-R digit symbol: SMD=-0.16, p=0.29; Trail Making Test Part B: SMD=-0.14, p=0.23; Stroop color-word interference: SMD=-0.16, p=0.18; phonemic verbal fluency: bilateral DBS SMD=-0.04, p=0.73, and unilateral DBS SMD=-0.05, p=0.83; semantic verbal fluency: bilateral DBS SMD=-0.09, p=0.37, and unilateral DBS SMD=-0.29, p=0.22; Boston Naming Test: SMD=-0.11, p=0.33; Beck Depression Inventory: bilateral DBS SMD=0.15, p=0.31, and unilateral DBS SMD=0.36, p=0.11). There was no statistically significant difference in most of the neuropsychological outcomes. The present evidence does not favor any of the targets in terms of neuropsychological performance.
Short circuit in deep brain stimulation.
Samura, Kazuhiro; Miyagi, Yasushi; Okamoto, Tsuyoshi; Hayami, Takehito; Kishimoto, Junji; Katano, Mitsuo; Kamikaseda, Kazufumi
2012-11-01
The authors undertook this study to investigate the incidence, cause, and clinical influence of short circuits in patients treated with deep brain stimulation (DBS). After the incidental identification of a short circuit during routine follow-up, the authors initiated a policy at their institution of routinely evaluating both therapeutic impedance and system impendence at every outpatient DBS follow-up visit, irrespective of the presence of symptoms suggesting possible system malfunction. This study represents a report of their findings after 1 year of this policy. Implanted DBS leads exhibiting short circuits were identified in 7 patients (8.9% of the patients seen for outpatient follow-up examinations during the 12-month study period). The mean duration from DBS lead implantation to the discovery of the short circuit was 64.7 months. The symptoms revealing short circuits included the wearing off of therapeutic effect, apraxia of eyelid opening, or dysarthria in 6 patients with Parkinson disease (PD), and dystonia deterioration in 1 patient with generalized dystonia. All DBS leads with short circuits had been anchored to the cranium using titanium miniplates. Altering electrode settings resulted in clinical improvement in the 2 PD cases in which patients had specific symptoms of short circuits (2.5%) but not in the other 4 cases. The patient with dystonia underwent repositioning and replacement of a lead because the previous lead was located too anteriorly, but did not experience symptom improvement. In contrast to the sudden loss of clinical efficacy of DBS caused by an open circuit, short circuits may arise due to a gradual decrease in impedance, causing the insidious development of neurological symptoms via limited or extended potential fields as well as shortened battery longevity. The incidence of short circuits in DBS may be higher than previously thought, especially in cases in which DBS leads are anchored with miniplates. The circuit impedance of DBS should be routinely checked, even after a long history of DBS therapy, especially in cases of miniplate anchoring.
Non-stationary discharge patterns in motor cortex under subthalamic nucleus deep brain stimulation.
Santaniello, Sabato; Montgomery, Erwin B; Gale, John T; Sarma, Sridevi V
2012-01-01
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) directly modulates the basal ganglia (BG), but how such stimulation impacts the cortex upstream is largely unknown. There is evidence of cortical activation in 6-hydroxydopamine (OHDA)-lesioned rodents and facilitation of motor evoked potentials in Parkinson's disease (PD) patients, but the impact of the DBS settings on the cortical activity in normal vs. Parkinsonian conditions is still debated. We use point process models to analyze non-stationary activation patterns and inter-neuronal dependencies in the motor and sensory cortices of two non-human primates during STN DBS. These features are enhanced after treatment with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP), which causes a consistent PD-like motor impairment, while high-frequency (HF) DBS (i.e., ≥100 Hz) strongly reduces the short-term patterns (period: 3-7 ms) both before and after MPTP treatment, and elicits a short-latency post-stimulus activation. Low-frequency DBS (i.e., ≤50 Hz), instead, has negligible effects on the non-stationary features. Finally, by using tools from the information theory [i.e., receiver operating characteristic (ROC) curve and information rate (IR)], we show that the predictive power of these models is dependent on the DBS settings, i.e., the probability of spiking of the cortical neurons (which is captured by the point process models) is significantly conditioned on the timely delivery of the DBS input. This dependency increases with the DBS frequency and is significantly larger for high- vs. low-frequency DBS. Overall, the selective suppression of non-stationary features and the increased modulation of the spike probability suggest that HF STN DBS enhances the neuronal activation in motor and sensory cortices, presumably because of reinforcement mechanisms, which perhaps involve the overlap between feedback antidromic and feed-forward orthodromic responses along the BG-thalamo-cortical loop.
Ross, Erika K; Kim, Joo Pyung; Settell, Megan L; Han, Seong Rok; Blaha, Charles D; Min, Hoon-Ki; Lee, Kendall H
2016-03-01
Deep brain stimulation (DBS) is a circuit-based treatment shown to relieve symptoms from multiple neurologic and neuropsychiatric disorders. In order to treat the memory deficit associated with Alzheimer's disease (AD), several clinical trials have tested the efficacy of DBS near the fornix. Early results from these studies indicated that patients who received fornix DBS experienced an improvement in memory and quality of life, yet the mechanisms behind this effect remain controversial. It is known that transmission between the medial limbic and corticolimbic circuits plays an integral role in declarative memory, and dysfunction at the circuit level results in various forms of dementia, including AD. Here, we aimed to determine the potential underlying mechanism of fornix DBS by examining the functional circuitry and brain structures engaged by fornix DBS. A multimodal approach was employed to examine global and local temporal changes that occur in an anesthetized swine model of fornix DBS. Changes in global functional activity were measured by functional MRI (fMRI), and local neurochemical changes were monitored by fast scan cyclic voltammetry (FSCV) during electrical stimulation of the fornix. Additionally, intracranial microinfusions into the nucleus accumbens (NAc) were performed to investigate the global activity changes that occur with dopamine and glutamate receptor-specific antagonism. Hemodynamic responses in both medial limbic and corticolimbic circuits measured by fMRI were induced by fornix DBS. Additionally, fornix DBS resulted in increases in dopamine oxidation current (corresponding to dopamine efflux) monitored by FSCV in the NAc. Finally, fornix DBS-evoked hemodynamic responses in the amygdala and hippocampus decreased following dopamine and glutamate receptor antagonism in the NAc. The present findings suggest that fornix DBS modulates dopamine release on presynaptic dopaminergic terminals in the NAc, involving excitatory glutamatergic input, and that the medial limbic and corticolimbic circuits interact in a functional loop. Copyright © 2016 Elsevier Inc. All rights reserved.
Hierarchical colorant-based direct binary search halftoning.
He, Zhen
2010-07-01
Colorant-based direct binary search (CB-DBS) halftoning proposed in provides an image quality benchmark for dispersed-dot halftoning algorithms. The objective of this paper is to further push the image quality limit. An algorithm called hierarchical colorant-based direct binary search (HCB-DBS) is developed in this paper. By appropriately integrating yellow colorant into dot-overlapping and dot-positioning controls, it is demonstrated that HCB-DBS can achieve better halftone texture of both individual and joint dot-color planes, without compromising the dot distribution of more visible halftone of cyan and magenta colorants. The input color specification is first converted from colorant space to dot-color space with minimum brightness variation principle for full dot-overlapping control. The dot-colors are then split into groups based upon dot visibility. Hierarchical monochrome DBS halftoning is applied to make dot-positioning decision for each group, constrained on the already generated halftone of the groups with higher priority. And dot-coloring is decided recursively with joint monochrome DBS halftoning constrained on the related total dot distribution. Experiments show HCB-DBS improves halftone texture for both individual and joint dot-color planes. And it reduces the halftone graininess and free of color mottle artifacts, comparing to CB-DBS.
Sustained Medication Reduction Following Unilateral VIM Thalamic Stimulation for Essential Tremor.
Resnick, Andrew S; Okun, Michael S; Malapira, Teresita; Smith, Donald; Vale, Fernando L; Sullivan, Kelly; Miller, Amber; Jahan, Israt; Zesiewicz, Theresa
2012-01-01
Deep brain stimulation (DBS) is an increasingly utilized therapeutic modality for the management of medication refractory essential tremor (ET). The aim of this study was to determine whether DBS allowed for anti-tremor medication reduction within the year after the procedure was performed. We conducted a retrospective chart review and telephone interviews on 34 consecutive patients who had been diagnosed with ET, and who had undergone unilateral DBS surgery. Of the 34 patients in our cohort, 31 patients (91%) completely stopped all anti-tremor medications either before surgery (21 patients, 62%) or in the year following DBS surgery (10 patients, 29%). Patients who discontinued tremor medications before DBS surgery did so because their tremors either became refractory to anti-tremor medication, or they developed adverse events to tremor medications. Patients who stopped tremor medications after DBS surgery did so due to sufficient tremor control. Only three patients (9%) who were taking tremor medications at the time of surgery continued the use of a beta-blocker post-operatively for the purpose of hypertension management in all cases. The data from this study indicate that medication cessation is common following unilateral DBS for ET.
Sustained Medication Reduction Following Unilateral VIM Thalamic Stimulation for Essential Tremor
Resnick, Andrew S.; Okun, Michael S.; Malapira, Teresita; Smith, Donald; Vale, Fernando L.; Sullivan, Kelly; Miller, Amber; Jahan, Israt; Zesiewicz, Theresa
2012-01-01
Background Deep brain stimulation (DBS) is an increasingly utilized therapeutic modality for the management of medication refractory essential tremor (ET). The aim of this study was to determine whether DBS allowed for anti-tremor medication reduction within the year after the procedure was performed. Methods We conducted a retrospective chart review and telephone interviews on 34 consecutive patients who had been diagnosed with ET, and who had undergone unilateral DBS surgery. Results Of the 34 patients in our cohort, 31 patients (91%) completely stopped all anti-tremor medications either before surgery (21 patients, 62%) or in the year following DBS surgery (10 patients, 29%). Patients who discontinued tremor medications before DBS surgery did so because their tremors either became refractory to anti-tremor medication, or they developed adverse events to tremor medications. Patients who stopped tremor medications after DBS surgery did so due to sufficient tremor control. Only three patients (9%) who were taking tremor medications at the time of surgery continued the use of a beta-blocker post-operatively for the purpose of hypertension management in all cases. Discussion The data from this study indicate that medication cessation is common following unilateral DBS for ET. PMID:23440408
Effects of dopaminergic and subthalamic stimulation on musical performance.
van Vugt, Floris T; Schüpbach, Michael; Altenmüller, Eckart; Bardinet, Eric; Yelnik, Jérôme; Hälbig, Thomas D
2013-05-01
Although subthalamic-deep brain stimulation (STN-DBS) is an efficient treatment for Parkinson's disease (PD), its effects on fine motor functions are not clear. We present the case of a professional violinist with PD treated with STN-DBS. DBS improved musical articulation, intonation and emotional expression and worsened timing relative to a timekeeper (metronome). The same effects were found for dopaminergic treatment. These results suggest that STN-DBS, mimicking the effects of dopaminergic stimulation, improves fine-tuned motor behaviour whilst impairing timing precision.
Telecommunications: Issues in Providing Cable and Satellite Television Services
NASA Astrophysics Data System (ADS)
2002-10-01
This report provides information on (1) whether the availability of cable modem Internet access service appears to be affecting the competitiveness of direct broadcast satellite (DBS) companies in the provision of video services, (2) whether cable prices and DBS penetration rates appear to be affected in areas where the DBS companies offer local broadcast channels, and (3) whether the two individual DBS companies are technologically capable of expanding local broadcast channel services into all 210 television markets in the United States.
Tanaka, Yasuhiro; Tsuboi, Takashi; Watanabe, Hirohisa; Kajita, Yasukazu; Nakatsubo, Daisuke; Fujimoto, Yasushi; Ohdake, Reiko; Ito, Mizuki; Atsuta, Naoki; Yamamoto, Masahiko; Wakabayashi, Toshihiko; Katsuno, Masahisa; Sobue, Gen
2016-10-19
Voice and speech disorders are one of the most important issues after subthalamic nucleus deep brain stimulation (STN-DBS) in Parkinson's disease (PD) patients. However, articulation features in this patient population remain unclear. We studied the articulation features of PD patients with STN-DBS. Participants were 56 PD patients treated with STN-DBS (STN-DBS group) and 41 patients treated only with medical therapy (medical-therapy-alone group). Articulation function was evaluated with acoustic and auditory-perceptual analyses. The vowel space area (VSA) was calculated using the formant frequency data of three vowels (/a/, /i/, and /u/) from sustained phonation task. The VSA reportedly reflects the distance of mouth/jaw and tongue movements during speech and phonation. Correlations between acoustic and auditory-perceptual measurements were also assessed. The VSA did not significantly differ between the medical-therapy-alone group and the STN-DBS group in the off-stimulation condition. In the STN-DBS group, the VSA was larger in the on-stimulation condition than in the off-stimulation condition. However, individual analysis showed the VSA changes after stopping stimulation were heterogeneous. In total, 89.8% of the STN-DBS group showed a large VSA size in the on- than in the off-stimulation condition. In contrast, the VSA of the remaining patients in that group was smaller in the on- than the off-stimulation condition. STN-DBS may resolve hypokinesia of the articulation structures, including the mouth/jaw and tongue, and improve maximal vowel articulation. However, in the on-stimulation condition, the VSA was not significantly correlated with speech intelligibility. This may be because STN-DBS potentially affects other speech processes such as voice and/or respiratory process.
Wagamitsu, Shunsuke; Takase, Dan; Aoki, Fugaku; Suzuki, Masataka G
2017-02-01
Normal sexual differentiation in the genital organs is essential for the animal species that use sexual reproduction. Although it is known that doublesex (dsx) is required for the sexual development of the genitalia in various insect species, the direct target genes responsible for the sexual differentiation of the genitalia have not been identified. The lozenge (lz) gene is expressed in the female genital disc and is essential for developments of spermathecae and accessory glands in Drosophila melanogaster. The female-specific isoform of DSX (DSXF) is required for activating lz expression in the female genital disc. However, it still remains unclear whether the DSXF directly activates the transcription of lz in the female genital disc. In this study, we found two sequences (lz-DBS1 and lz-DBS2) within lz locus that showed high homoloty to the DSX binding motif identified previously. Competition assays using recombinant DSX DNA-binding domain (DSX-DBD) protein verified that the DSX-DBD protein bound to lz-DBS1 and lz-DBS2 in a sequence-specific manner with lower affinity than to the known DSX binding site in the bric-à-brac 1 (bab1) gene. Reporter gene analyses revealed that a 2.5-kbp lz genomic fragment containing lz-DBS1 and lz-DBS2 drove reporter gene (EGFP) expression in a manner similar to endogenous lz expression in the female genital disc. Mutations in lz-DBS1 alone significantly reduced the area of EGFP-expressing region, while EGFP expression in the female genital disc was abolished when both sites were mutated. These results demonstrated that DSX directly activates female-specific lz expression in the genital disc through lz-DBS1 and lz-DBS2. Copyright © 2017 Elsevier B.V. All rights reserved.
Sommansson, Anna; Wan Saudi, Wan Salman; Nylander, Olof; Sjöblom, Markus
2014-01-01
Alcohol may induce metabolic and functional changes in gastrointestinal epithelial cells, contributing to impaired mucosal barrier function. Duodenal mucosal bicarbonate secretion (DBS) is a primary epithelial defense against gastric acid and also has an important function in maintaining the homeostasis of the juxtamucosal microenvironment. The aim in this study was to investigate the effects of the luminal perfusion of moderate concentrations of ethanol in vivo on epithelial DBS, fluid secretion and paracellular permeability. Under thiobarbiturate anesthesia, a ∼30-mm segment of the proximal duodenum with an intact blood supply was perfused in situ in rats. The effects on DBS, duodenal transepithelial net fluid flux and the blood-to-lumen clearance of 51Cr-EDTA were investigated. Perfusing the duodenum with isotonic solutions of 10% or 15% ethanol-by-volume for 30 min increased DBS in a concentration-dependent manner, while the net fluid flux did not change. Pre-treatment with the CFTR inhibitor CFTRinh172 (i.p. or i.v.) did not change the secretory response to ethanol, while removing Cl− from the luminal perfusate abolished the ethanol-induced increase in DBS. The administration of hexamethonium (i.v.) but not capsazepine significantly reduced the basal net fluid flux and the ethanol-induced increase in DBS. Perfusing the duodenum with a combination of 1.0 mM HCl and 15% ethanol induced significantly greater increases in DBS than 15% ethanol or 1.0 mM HCl alone but did not influence fluid flux. Our data demonstrate that ethanol induces increases in DBS through a mechanism that is critically dependent on luminal Cl− and partly dependent on enteric neural pathways involving nicotinic receptors. Ethanol and HCl appears to stimulate DBS via the activation of different bicarbonate transporting mechanisms. PMID:25033198
Hack, Nawaz; Akbar, Umer; Thompson-Avila, Amanda; Fayad, Sarah M; Hastings, Erin M; Moro, Elena; Nestor, Kelsey; Ward, Herbert; York, Michele; Okun, Michael S
2014-01-01
Impulse control disorders (ICDs), dopamine dysregulation syndrome (DDS), and dopamine agonist withdrawal syndrome (DAWS) have been reported commonly in Parkinson's disease (PD) populations. The treatment approaches may be widely variable and there is not much information on these syndromes in the setting of deep brain stimulation (DBS). To evaluate (1) ICDs, DAWS and DDS pre- and post DBS in PD and (2) to investigate pre-DBS treatment strategies regarding these behaviors among Parkinson Study Group (PSG) centers. Forty-eight PSG centers were surveyed on ICDs, DAWS and DDS, as well as on potential relationships to DBS and treatment approaches. Sixty-seven percent of PSG centers reported that they served a population of over 500 PD patients per year, and 94% of centers performed DBS surgery. Most centers (92%) reported screening for ICDs, DAWS and DDS. Of the centers screening for these symptoms, 13% reported always employing a formal battery of pre-operative tests, 46% of sites inconsistently used a formal battery, while 23% of sites reported never using a formal battery to screen for these symptoms. The estimated numbers of centers observing ICDs, DAWS and DDS pre-operatively in individuals with PD were 71%, 69%, and 69%, respectively. PSG DBS centers observing at least one case of a new de novo occurrence of an ICD, DAWS or DDS after DBS surgery were 67%, 65% and 65%, respectively. The results suggest that addiction-like syndromes and withdrawal syndromes are prevalent in expert PSG centers performing DBS. Most centers reported screening for these issues without the use of a formal battery, and there were a large number of centers reporting ICDs, DAWS and DDS post-DBS. A single treatment strategy did not emerge.
Brandt, Jason; Rogerson, Mark; Al-Joudi, Haya; Reckess, Gila; Shpritz, Barnett; Umeh, Chizoba C.; Aljehani, Noha; Mills, Kelly; Mari, Zoltan
2014-01-01
Objective Concerns persist that deep brain stimulation (DBS) for Parkinson’s disease (PD) increases impulsivity and/or induces excessive reward-seeking. We report here the performance of PD patients with implanted subthalamic nucleus electrodes, with stimulation on and off, on three laboratory tasks of risk-taking and decision-making. They are compared to PD patients maintained on medication and normal control subjects. Methods and Results In the Game of Dice Task, a test of “risky” decision-making, PD patients with or without DBS made highest-risk bets more often, and ended up with less money, than normal controls. There was a trend for DBS stimulation to ameliorate this effect. Deal or No-Deal is an “ambiguous” decision-making task that assessed preference for risk (holding on to one’s briefcase) over a “sure thing” (accepting the banker’s offer). Here, DBS patients were more conservative with stimulation on than off. They accepted smaller offers from the banker and won less money in the DBS-on condition. Overall, the two PD groups won less money than healthy participants. The Framing Paradigm assessed willingness to gamble on a fixed (unambiguous) prize depending on whether the reward was “framed” as a loss or a gain. Nonsurgical PD patients tended to be more risk-averse than normal subjects, whereas DBS patients were more willing to gamble for gains as well as losses both on and off stimulation. Conclusions On “risky” decision-making tasks, DBS patients were more risk-taking than normal, but stimulation may temper this tendency. In contrast, in an “ambiguous risk” situation, DBS patients were more risk-averse (conservative) than normal, and this tendency was greatest with stimulation. PMID:25486385
Sommansson, Anna; Wan Saudi, Wan Salman; Nylander, Olof; Sjöblom, Markus
2014-01-01
Alcohol may induce metabolic and functional changes in gastrointestinal epithelial cells, contributing to impaired mucosal barrier function. Duodenal mucosal bicarbonate secretion (DBS) is a primary epithelial defense against gastric acid and also has an important function in maintaining the homeostasis of the juxtamucosal microenvironment. The aim in this study was to investigate the effects of the luminal perfusion of moderate concentrations of ethanol in vivo on epithelial DBS, fluid secretion and paracellular permeability. Under thiobarbiturate anesthesia, a ∼30-mm segment of the proximal duodenum with an intact blood supply was perfused in situ in rats. The effects on DBS, duodenal transepithelial net fluid flux and the blood-to-lumen clearance of 51Cr-EDTA were investigated. Perfusing the duodenum with isotonic solutions of 10% or 15% ethanol-by-volume for 30 min increased DBS in a concentration-dependent manner, while the net fluid flux did not change. Pre-treatment with the CFTR inhibitor CFTRinh172 (i.p. or i.v.) did not change the secretory response to ethanol, while removing Cl- from the luminal perfusate abolished the ethanol-induced increase in DBS. The administration of hexamethonium (i.v.) but not capsazepine significantly reduced the basal net fluid flux and the ethanol-induced increase in DBS. Perfusing the duodenum with a combination of 1.0 mM HCl and 15% ethanol induced significantly greater increases in DBS than 15% ethanol or 1.0 mM HCl alone but did not influence fluid flux. Our data demonstrate that ethanol induces increases in DBS through a mechanism that is critically dependent on luminal Cl- and partly dependent on enteric neural pathways involving nicotinic receptors. Ethanol and HCl appears to stimulate DBS via the activation of different bicarbonate transporting mechanisms.
Brandt, Jason; Rogerson, Mark; Al-Joudi, Haya; Reckess, Gila; Shpritz, Barnett; Umeh, Chizoba C; Aljehani, Noha; Mills, Kelly; Mari, Zoltan
2015-07-01
Concerns persist that deep brain stimulation (DBS) for Parkinson's disease (PD) increases impulsivity or induces excessive reward seeking. We report here the performance of PD patients with implanted subthalamic nucleus electrodes, with stimulation on and off, on 3 laboratory tasks of risk taking and decision making. They are compared with PD patients maintained on medication and healthy participants. In the Game of Dice Task, a test of "risky" decision making, PD patients with or without DBS made highest risk bets more often and ended up with less money than did healthy participants. There was a trend for DBS stimulation to ameliorate this effect. Deal or No-Deal is an "ambiguous" decision-making task that assessed preference for risk (holding on to one's briefcase) over a "sure thing" (accepting the banker's offer). Here, DBS patients were more conservative with stimulation on than with it off. They accepted smaller offers from the banker and won less money in the DBS-on condition. Overall, the 2 PD groups won less money than did healthy participants. The Framing Paradigm assessed willingness to gamble on a fixed (unambiguous) prize depending on whether the reward was "framed" as a loss or a gain. Nonsurgical PD patients tended to be more risk-averse than were healthy participants, whereas DBS patients were more willing to gamble for gains as well as losses both on and off stimulation. On risky decision-making tasks, DBS patients took more risks than did healthy participants, but stimulation may temper this tendency. In contrast, in an ambiguous-risk situation, DBS patients were more risk-averse (conservative) than were healthy participants, and this tendency was greatest with stimulation. (c) 2015 APA, all rights reserved).
Diestro, Jose Danilo B; Vesagas, Theodor S; Teleg, Rosalia A; Aguilar, Jose A; Anlacan, Joseph P; Jamora, Roland Dominic G
2018-04-28
Deep brain stimulation (DBS) is an established treatment modality for Parkinson disease (PD). The first DBS for PD in the Philippines was performed at the Philippine Movement Disorder Surgery Center in 2006. There are no Philippine data on DBS for PD. We aim to determine the motor improvement and reduction in medication dosage of all patients with PD who underwent DBS at the Philippine Movement Disorder Surgery Center. This is a retrospective study of all patients with PD (n = 17) who underwent DBS from 2006 to 2016. The change in the Unified Parkinson's Disease Rating Scale (UPDRS) motor and levodopa equivalent dose were determined. There was a statistically significant reduction in the UPDRS motor in all patients off medication at 3 months (48.2%; P = 0.004), 1 year (47.3%; P = 0.026), 2 years (48.4%; P = 0.021), and 3 years (66.0%; P = 0.032) after DBS and on medication at 3 months (43.3%; P = 0.023), 6 months (24.7%; P = 0.053), and 1 year (38.1%; P = 0.033). A significant reduction in the dosage of PD medications was also seen until the second year of follow-up (52.3%; P < 0.001). Adverse events included an attempted suicide and a device-related infection. DBS for PD improves the UPDRS motor score in the off-medication and on-medication state, with the maximal benefit seen at 3 years after surgery and reduces PD medication dosage by half. Although the benefit from DBS is undeniable, the high cost of the procedure precludes more patients from benefitting from it. There is a need for government support to expand access to DBS. Copyright © 2018 Elsevier Inc. All rights reserved.
Intestinal alkaline phosphatase regulates protective surface microclimate pH in rat duodenum.
Mizumori, Misa; Ham, Maggie; Guth, Paul H; Engel, Eli; Kaunitz, Jonathan D; Akiba, Yasutada
2009-07-15
Regulation of localized extracellular pH (pH(o)) maintains normal organ function. An alkaline microclimate overlying the duodenal enterocyte brush border protects the mucosa from luminal acid. We hypothesized that intestinal alkaline phosphatase (IAP) regulates pH(o) due to pH-sensitive ATP hydrolysis as part of an ecto-purinergic pH regulatory system, comprised of cell-surface P2Y receptors and ATP-stimulated duodenal bicarbonate secretion (DBS). To test this hypothesis, we measured DBS in a perfused rat duodenal loop, examining the effect of the competitive alkaline phosphatase inhibitor glycerol phosphate (GP), the ecto-nucleoside triphosphate diphosphohydrolase inhibitor ARL67156, and exogenous nucleotides or P2 receptor agonists on DBS. Furthermore, we measured perfusate ATP concentration with a luciferin-luciferase bioassay. IAP inhibition increased DBS and luminal ATP output. Increased luminal ATP output was partially CFTR dependent, but was not due to cellular injury. Immunofluorescence localized the P2Y(1) receptor to the brush border membrane of duodenal villi. The P2Y(1) agonist 2-methylthio-ADP increased DBS, whereas the P2Y(1) antagonist MRS2179 reduced ATP- or GP-induced DBS. Acid perfusion augmented DBS and ATP release, further enhanced by the IAP inhibitor l-cysteine, and reduced by the exogenous ATPase apyrase. Furthermore, MRS2179 or the highly selective P2Y(1) antagonist MRS2500 co-perfused with acid induced epithelial injury, suggesting that IAP/ATP/P2Y signalling protects the mucosa from acid injury. Increased DBS augments IAP activity presumably by raising pH(o), increasing the rate of ATP degradation, decreasing ATP-mediated DBS, forming a negative feedback loop. The duodenal epithelial brush border IAP-P2Y-HCO(3-) surface microclimate pH regulatory system effectively protects the mucosa from acid injury.
Williams, Isobel Anne; Wilkinson, Leonora; Limousin, Patricia; Jahanshahi, Marjan
2015-01-01
Deep brain stimulation of the subthalamic nucleus (STN DBS) ameliorates the motor symptoms of Parkinson's disease (PD). However, some aspects of executive control are impaired with STN DBS. We tested the prediction that (i) STN DBS interferes with switching from automatic to controlled processing during fast-paced random number generation (RNG) (ii) STN DBS-induced cognitive control changes are load-dependent. Fifteen PD patients with bilateral STN DBS performed paced-RNG, under three levels of cognitive load synchronised with a pacing stimulus presented at 1, 0.5 and 0.33 Hz (faster rates require greater cognitive control), with DBS on or off. Measures of output randomness were calculated. Countscore 1 (CS1) indicates habitual counting in steps of one (CS1). Countscore 2 (CS2) indicates a more controlled strategy of counting in twos. The fastest rate was associated with an increased CS1 score with STN DBS on compared to off. At the slowest rate, patients had higher CS2 scores with DBS off than on, such that the differences between CS1 and CS2 scores disappeared. We provide evidence for a load-dependent effect of STN DBS on paced RNG in PD. Patients could switch to more controlled RNG strategies during conditions of low cognitive load at slower rates only when the STN stimulators were off, but when STN stimulation was on, they engaged in more automatic habitual counting under increased cognitive load. These findings are consistent with the proposal that the STN implements a switch signal from the medial frontal cortex which enables a shift from automatic to controlled processing.
Mohseni, Hamid R.; Smith, Penny P.; Parsons, Christine E.; Young, Katherine S.; Hyam, Jonathan A.; Stein, Alan; Stein, John F.; Green, Alexander L.; Aziz, Tipu Z.; Kringelbach, Morten L.
2012-01-01
Deep brain stimulation (DBS) has been shown to be clinically effective for some forms of treatment-resistant chronic pain, but the precise mechanisms of action are not well understood. Here, we present an analysis of magnetoencephalography (MEG) data from a patient with whole-body chronic pain, in order to investigate changes in neural activity induced by DBS for pain relief over both short- and long-term. This patient is one of the few cases treated using DBS of the anterior cingulate cortex (ACC). We demonstrate that a novel method, null-beamforming, can be used to localise accurately brain activity despite the artefacts caused by the presence of DBS electrodes and stimulus pulses. The accuracy of our source localisation was verified by correlating the predicted DBS electrode positions with their actual positions. Using this beamforming method, we examined changes in whole-brain activity comparing pain relief achieved with deep brain stimulation (DBS ON) and compared with pain experienced with no stimulation (DBS OFF). We found significant changes in activity in pain-related regions including the pre-supplementary motor area, brainstem (periaqueductal gray) and dissociable parts of caudal and rostral ACC. In particular, when the patient reported experiencing pain, there was increased activity in different regions of ACC compared to when he experienced pain relief. We were also able to demonstrate long-term functional brain changes as a result of continuous DBS over one year, leading to specific changes in the activity in dissociable regions of caudal and rostral ACC. These results broaden our understanding of the underlying mechanisms of DBS in the human brain. PMID:22675503
NASA Astrophysics Data System (ADS)
Keane, Maureen; Deyo, Steve; Abosch, Aviva; Bajwa, Jawad A.; Johnson, Matthew D.
2012-08-01
Deep brain stimulation (DBS) in the ventral intermediate nucleus of thalamus (Vim) is known to exert a therapeutic effect on postural and kinetic tremor in patients with essential tremor (ET). For DBS leads implanted near the caudal border of Vim, however, there is an increased likelihood that one will also induce paresthesia side-effects by stimulating neurons within the sensory pathway of the ventral caudal (Vc) nucleus of thalamus. The aim of this computational study was to (1) investigate the neuronal pathways modulated by therapeutic, sub-therapeutic and paresthesia-inducing DBS settings in three patients with ET and (2) determine how much better an outcome could have been achieved had these patients been implanted with a DBS lead containing directionally segmented electrodes (dDBS). Multi-compartment neuron models of the thalamocortical, cerebellothalamic and medial lemniscal pathways were first simulated in the context of patient-specific anatomies, lead placements and programming parameters from three ET patients who had been implanted with Medtronic 3389 DBS leads. The models showed that in these patients, complete suppression of tremor was associated most closely with activating an average of 62% of the cerebellothalamic afferent input into Vim (n = 10), while persistent paresthesias were associated with activating 35% of the medial lemniscal tract input into Vc thalamus (n = 12). The dDBS lead design demonstrated superior targeting of the cerebello-thalamo-cortical pathway, especially in cases of misaligned DBS leads. Given the close proximity of Vim to Vc thalamus, the models suggest that dDBS will enable clinicians to more effectively sculpt current through and around thalamus in order to achieve a more consistent therapeutic effect without inducing side-effects.
Schmuckermair, Claudia; Gaburro, Stefano; Sah, Anupam; Landgraf, Rainer; Sartori, Simone B; Singewald, Nicolas
2013-01-01
Increasing evidence suggests that high-frequency deep brain stimulation of the nucleus accumbens (NAcb-DBS) may represent a novel therapeutic strategy for individuals suffering from treatment-resistant depression, although the underlying mechanisms of action remain largely unknown. In this study, using a unique mouse model of enhanced depression- and anxiety-like behavior (HAB), we investigated behavioral and neurobiological effects of NAcb-DBS. HAB mice either underwent chronic treatment with one of three different selective serotonin reuptake inhibitors (SSRIs) or received NAcb-DBS for 1 h per day for 7 consecutive days. Animals were tested in established paradigms revealing depression- and anxiety-related behaviors. The enhanced depression-like behavior of HAB mice was not influenced by chronic SSRI treatment. In contrast, repeated, but not single, NAcb-DBS induced robust antidepressant and anxiolytic responses in HAB animals, while these behaviors remained unaffected in normal depression/anxiety animals (NAB), suggesting a preferential effect of NAcb-DBS on pathophysiologically deranged systems. NAcb-DBS caused a modulation of challenge-induced activity in various stress- and depression-related brain regions, including an increase in c-Fos expression in the dentate gyrus of the hippocampus and enhanced hippocampal neurogenesis in HABs. Taken together, these findings show that the normalization of the pathophysiologically enhanced, SSRI-insensitive depression-like behavior by repeated NAcb-DBS was associated with the reversal of reported aberrant brain activity and impaired adult neurogenesis in HAB mice, indicating that NAcb-DBS affects neuronal activity as well as plasticity in a defined, mood-associated network. Thus, HAB mice may represent a clinically relevant model for elucidating the neurobiological correlates of NAcb-DBS. PMID:23325324
Bot, Maarten; Schuurman, P Richard; Odekerken, Vincent J J; Verhagen, Rens; Contarino, Fiorella Maria; De Bie, Rob M A; van den Munckhof, Pepijn
2018-05-01
Individual motor improvement after deep brain stimulation (DBS) of the subthalamic nucleus (STN) for Parkinson's disease (PD) varies considerably. Stereotactic targeting of the dorsolateral sensorimotor part of the STN is considered paramount for maximising effectiveness, but studies employing the midcommissural point (MCP) as anatomical reference failed to show correlation between DBS location and motor improvement. The medial border of the STN as reference may provide better insight in the relationship between DBS location and clinical outcome. Motor improvement after 12 months of 65 STN DBS electrodes was categorised into non-responding, responding and optimally responding body-sides. Stereotactic coordinates of optimal electrode contacts relative to both medial STN border and MCP served to define theoretic DBS 'hotspots'. Using the medial STN border as reference, significant negative correlation (Pearson's correlation -0.52, P<0.01) was found between the Euclidean distance from the centre of stimulation to this DBS hotspot and motor improvement. This hotspot was located at 2.8 mm lateral, 1.7 mm anterior and 2.5 mm superior relative to the medial STN border. Using MCP as reference, no correlation was found. The medial STN border proved superior compared with MCP as anatomical reference for correlation of DBS location and motor improvement, and enabled defining an optimal DBS location within the nucleus. We therefore propose the medial STN border as a better individual reference point than the currently used MCP on preoperative stereotactic imaging, in order to obtain optimal and thus less variable motor improvement for individual patients with PD following STN DBS. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Subthalamic nucleus deep brain stimulation improves somatosensory function in Parkinson's disease.
Aman, Joshua E; Abosch, Aviva; Bebler, Maggie; Lu, Chia-Hao; Konczak, Jürgen
2014-02-01
An established treatment for the motor symptoms of Parkinson's disease (PD) is deep brain stimulation (DBS) of the subthalamic nucleus (STN). Mounting evidence suggests that PD is also associated with somatosensory deficits, yet the effect of STN-DBS on somatosensory processing is largely unknown. This study investigated whether STN-DBS affects somatosensory processing, specifically the processing of tactile and proprioceptive cues, by systematically examining the accuracy of haptic perception of object size. (Haptic perception refers to one's ability to extract object features such as shape and size by active touch.) Without vision, 13 PD patients with implanted STN-DBS and 13 healthy controls haptically explored the heights of 2 successively presented 3-dimensional (3D) blocks using a precision grip. Participants verbally indicated which block was taller and then used their nonprobing hand to motorically match the perceived size of the comparison block. Patients were tested during ON and OFF stimulation, following a 12-hour medication washout period. First, when compared to controls, the PD group's haptic discrimination threshold during OFF stimulation was elevated by 192% and mean hand aperture error was increased by 105%. Second, DBS lowered the haptic discrimination threshold by 26% and aperture error decreased by 20%. Third, during DBS ON, probing with the motorically more affected hand decreased haptic precision compared to probing with the less affected hand. This study offers the first evidence that STN-DBS improves haptic precision, further indicating that somatosensory function is improved by STN-DBS. We conclude that DBS-related improvements are not explained by improvements in motor function alone, but rather by enhanced somatosensory processing. © 2013 Movement Disorder Society.
Williams, Isobel Anne; Wilkinson, Leonora; Limousin, Patricia; Jahanshahi, Marjan
2015-01-01
Background: Deep brain stimulation of the subthalamic nucleus (STN DBS) ameliorates the motor symptoms of Parkinson’s disease (PD). However, some aspects of executive control are impaired with STN DBS. Objective: We tested the prediction that (i) STN DBS interferes with switching from automatic to controlled processing during fast-paced random number generation (RNG) (ii) STN DBS-induced cognitive control changes are load-dependent. Methods: Fifteen PD patients with bilateral STN DBS performed paced-RNG, under three levels of cognitive load synchronised with a pacing stimulus presented at 1, 0.5 and 0.33 Hz (faster rates require greater cognitive control), with DBS on or off. Measures of output randomness were calculated. Countscore 1 (CS1) indicates habitual counting in steps of one (CS1). Countscore 2 (CS2) indicates a more controlled strategy of counting in twos. Results: The fastest rate was associated with an increased CS1 score with STN DBS on compared to off. At the slowest rate, patients had higher CS2 scores with DBS off than on, such that the differences between CS1 and CS2 scores disappeared. Conclusions: We provide evidence for a load-dependent effect of STN DBS on paced RNG in PD. Patients could switch to more controlled RNG strategies during conditions of low cognitive load at slower rates only when the STN stimulators were off, but when STN stimulation was on, they engaged in more automatic habitual counting under increased cognitive load. These findings are consistent with the proposal that the STN implements a switch signal from the medial frontal cortex which enables a shift from automatic to controlled processing. PMID:25720447
Network effects of deep brain stimulation
Alhourani, Ahmad; McDowell, Michael M.; Randazzo, Michael J.; Wozny, Thomas A.; Kondylis, Efstathios D.; Lipski, Witold J.; Beck, Sarah; Karp, Jordan F.; Ghuman, Avniel S.
2015-01-01
The ability to differentially alter specific brain functions via deep brain stimulation (DBS) represents a monumental advance in clinical neuroscience, as well as within medicine as a whole. Despite the efficacy of DBS in the treatment of movement disorders, for which it is often the gold-standard therapy when medical management becomes inadequate, the mechanisms through which DBS in various brain targets produces therapeutic effects is still not well understood. This limited knowledge is a barrier to improving efficacy and reducing side effects in clinical brain stimulation. A field of study related to assessing the network effects of DBS is gradually emerging that promises to reveal aspects of the underlying pathophysiology of various brain disorders and their response to DBS that will be critical to advancing the field. This review summarizes the nascent literature related to network effects of DBS measured by cerebral blood flow and metabolic imaging, functional imaging, and electrophysiology (scalp and intracranial electroencephalography and magnetoencephalography) in order to establish a framework for future studies. PMID:26269552
Fornix deep brain stimulation enhances acetylcholine levels in the hippocampus.
Hescham, Sarah; Jahanshahi, Ali; Schweimer, Judith V; Mitchell, Stephen N; Carter, Guy; Blokland, Arjan; Sharp, Trevor; Temel, Yasin
2016-11-01
Deep brain stimulation (DBS) of the fornix has gained interest as a potential therapy for advanced treatment-resistant dementia, yet the mechanism of action remains widely unknown. Previously, we have reported beneficial memory effects of fornix DBS in a scopolamine-induced rat model of dementia, which is dependent on various brain structures including hippocampus. To elucidate mechanisms of action of fornix DBS with regard to memory restoration, we performed c-Fos immunohistochemistry in the hippocampus. We found that fornix DBS induced a selective activation of cells in the CA1 and CA3 subfields of the dorsal hippocampus. In addition, hippocampal neurotransmitter levels were measured using microdialysis before, during and after 60 min of fornix DBS in a next experiment. We observed a substantial increase in the levels of extracellular hippocampal acetylcholine, which peaked 20 min after stimulus onset. Interestingly, hippocampal glutamate levels did not change compared to baseline. Therefore, our findings provide first experimental evidence that fornix DBS activates the hippocampus and induces the release of acetylcholine in this region.
State of the Art: Novel Applications for Deep Brain Stimulation.
Roy, Holly A; Green, Alexander L; Aziz, Tipu Z
2018-02-01
Deep brain stimulation (DBS) is a rapidly developing field of neurosurgery with potential therapeutic applications that are relevant to conditions traditionally viewed as beyond the limits of neurosurgery. Our objective, in this review, is to highlight some of the emerging applications of DBS within three distinct but overlapping spheres, namely trauma, neuropsychiatry, and autonomic physiology. An extensive literature review was carried out in MEDLINE, to identify relevant studies and review articles describing applications of DBS in the areas of trauma, neuropsychiatry and autonomic neuroscience. A wide range of applications of DBS in these spheres was identified, some having only been tested in one or two cases, others much better studied. We have identified various avenues for DBS to be applied for patient benefit in cases relevant to trauma, neuropsychiatry and autonomic neuroscience. Further developments in DBS technology and clinical trial design will enable these novel applications to be effectively and rigorously assessed and utilized most effectively. © 2017 International Neuromodulation Society.
Mulders, Anne E P; Leentjens, Albert F G; Schruers, Koen; Duits, Annelien; Ackermans, Linda; Temel, Yasin
2017-08-01
Patients with treatment-resistant obsessive-compulsive disorder (OCD) are potential candidates for deep brain stimulation (DBS). The anteromedial subthalamic nucleus (STN) is among the most commonly used targets for DBS in OCD. We present a patient with a 30-year history of treatment-resistant OCD who underwent anteromedial STN-DBS. Despite a clear mood-enhancing effect, stimulation caused motor side effects, including bilateral hyperkinesia, dyskinesias, and sudden large amplitude choreatic movements of arms and legs when stimulating at voltages greater than approximately 1.5 V. DBS at lower amplitudes and at other contact points failed to result in a significant reduction of obsessions and compulsions without inducing motor side effects. Because of this limitation in programming options, we decided to reoperate and target the ventral capsule/ventral striatum (VC/VS), which resulted in a substantial reduction in key obsessive and compulsive symptoms without serious side effects. Choreatic movements and hemiballismus have previously been linked to STN dysfunction and have been incidentally reported as side effects of DBS of the dorsolateral STN in Parkinson disease (PD). However, in PD, these side effects were usually transient, and they rarely interfered with DBS programming. In our patient, the motor side effects were persistent, and they made optimal DBS programming impossible. To our knowledge, such severe and persistent motor side effects have not been described previously for anteromedial STN-DBS. Copyright © 2017 Elsevier Inc. All rights reserved.
Parkinson's disease patient preference and experience with various methods of DBS lead placement.
LaHue, Sara C; Ostrem, Jill L; Galifianakis, Nicholas B; San Luciano, Marta; Ziman, Nathan; Wang, Sarah; Racine, Caroline A; Starr, Philip A; Larson, Paul S; Katz, Maya
2017-08-01
Physiology-guided deep brain stimulation (DBS) surgery requires patients to be awake during a portion of the procedure, which may be poorly tolerated. Interventional MRI-guided (iMRI) DBS surgery was developed to use real-time image guidance, obviating the need for patients to be awake during lead placement. All English-speaking adults with PD who underwent iMRI DBS between 2010 and 2014 at our Center were invited to participate. Subjects completed a structured interview that explored perioperative preferences and experiences. We compared these responses to patients who underwent the physiology-guided method, matched for age and gender. Eighty-nine people with PD completed the study. Of those, 40 underwent iMRI, 44 underwent physiology-guided implantation, and five underwent both methods. There were no significant differences in baseline characteristics between groups. The primary reason for choosing iMRI DBS was a preference to be asleep during implantation due to: 1) a history of claustrophobia; 2) concerns about the potential for discomfort during the awake physiology-guided procedure in those with an underlying pain syndrome or severe off-medication symptoms; or 3) non-specific fear about being awake during neurosurgery. Participants were satisfied with both DBS surgery methods. However, identification of the factors associated with a preference for iMRI DBS may allow for optimization of patient experience and satisfaction when choices of surgical methods for DBS implantation are available. Published by Elsevier Ltd.
van Hartevelt, Tim J; Cabral, Joana; Møller, Arne; FitzGerald, James J; Green, Alexander L; Aziz, Tipu Z; Deco, Gustavo; Kringelbach, Morten L
2015-01-01
It is unclear whether Hebbian-like learning occurs at the level of long-range white matter connections in humans, i.e., where measurable changes in structural connectivity (SC) are correlated with changes in functional connectivity. However, the behavioral changes observed after deep brain stimulation (DBS) suggest the existence of such Hebbian-like mechanisms occurring at the structural level with functional consequences. In this rare case study, we obtained the full network of white matter connections of one patient with Parkinson's disease (PD) before and after long-term DBS and combined it with a computational model of ongoing activity to investigate the effects of DBS-induced long-term structural changes. The results show that the long-term effects of DBS on resting-state functional connectivity is best obtained in the computational model by changing the structural weights from the subthalamic nucleus (STN) to the putamen and the thalamus in a Hebbian-like manner. Moreover, long-term DBS also significantly changed the SC towards normality in terms of model-based measures of segregation and integration of information processing, two key concepts of brain organization. This novel approach using computational models to model the effects of Hebbian-like changes in SC allowed us to causally identify the possible underlying neural mechanisms of long-term DBS using rare case study data. In time, this could help predict the efficacy of individual DBS targeting and identify novel DBS targets.
Direct Broadcasting Satellite in the United States.
ERIC Educational Resources Information Center
Kim, Haeryon
The introduction of Direct Broadcasting Satellites (DBS) in the United States sparked both government's regulatory development of domestic DBS services and the communication industry's efforts to implement a commercial DBS system. J. D. Slack's symptomatic causality and technological assessment models help to explain how these practices were…
Haynes, Christopher A; Guerra, Stephanie L; Fontana, Jessalyn C; DeJesús, Víctor R
2013-09-23
Hemoglobinopathies are mutations resulting in abnormal globin chain structure; some have clinically significant outcomes such as anemia or reduced lifespan. Five β-globin mutations are (c.20A>T, p.E6V), (c.19G>A, p. E6K), (c.79G>A, p.E26K), (c.364G>C, p.E121Q), and (c.364G>A, p.E121K), resulting in HbS (sickle-cell hemoglobin), HbC, HbE, HbD-Los Angeles, and HbO-Arab, respectively. One α-globin mutation is (c.[207C>G or 207C>A], p.N68K), resulting in HbG-Philadelphia. HPLC-ESI-MS/MS analysis of dried-blood spot (DBS) punches from newborns extracted with a trypsin-containing solution provides greater than 90% coverage of α-, β-, and γ-globin amino acid sequences. Because the (c.20A>T, p.E6V), (c.19G>A, p. E6K), (c.79G>A, p.E26K), (c.364G>C, p.E121Q), (c.364G>A, p.E121K), and (c.[207C>G or 207C>A], p.N68K) mutations generate globin peptides with novel amino acid sequences, detecting one of these peptides in DBS extracts is indicative of the presence of a hemoglobinopathy in the newborn. The method described here can distinguish normal β-globin peptides from the mutant HbS, HbC, HbE, HbD-Los Angeles and HbO-Arab peptides, as well as normal α-globin peptide from the mutant HbG-Philadelphia peptide, allowing the identification of unaffected heterozygotes such as HbAS, and of compound heterozygotes such as HbASG-Philadelphia. This HPLC-ESI-MS/MS analytical approach provides information that is not available from traditional hemoglobin analyses such as isoelectric focusing and HPLC-UV. It is also capable of determining the amino acid sequence of hemoglobin peptides, potentially allowing the detection of numerous hemoglobinopathies resulting from point mutations. Published by Elsevier B.V.