Sample records for spring accelerometer isa

  1. The BepiColombo mission to Mercury: state of the art of the ISA accelerometer implementation onboard the Mercury Planetary Orbiter

    NASA Astrophysics Data System (ADS)

    Iafolla, V.; Lucchesi, D.; Fiorenza, E.; Lefevre, C.; Lucente, M.; Magnafico, C.; Peron, R.; Santoli, F.; Nozzoli, S.; Argada, A.

    2012-04-01

    The Italian Spring Accelerometer (ISA) has been selected by ESA to fly onboard the Mercury Planetary Orbiter (MPO) of the BepiColombo space mission. Mercury's exploration represents one of the most important challenges of modern planetary sciences and the mission aims to reach a much better understanding of the internal structure and composition of the planet, which in turn are needed for a deeper comprehension of the formation of the terrestrial planets, hence of that of our solar system. Moreover, because of its proximity to the Sun, Mercury represents a unique opportunity to test Einstein's theory for the gravitational interaction with respect to other proposed theories of gravitation. The BepiColombo Radio Science Experiments (RSE) are devoted to reach the above ambitious goals and the measurements of the onboard accelerometer are necessary to remove (a posteriori) the very complex to model, strong and subtle, non-gravitational accelerations due to the very strong radiation environment around Mercury. We focus on the accelerometer characteristics and performance, on the functional tests that are necessary for its implementation onboard the MPO and in the procedures that are necessary for the reduction of the accelerometer measurements in order to be used in the context of the RSE. We finally introduce the description of the accelerometer proof-masses non linearities, their impact in the measurements and the way to handle such effects.

  2. Signals and Noises Acting On The Accelerometer Mounted In The Mpo (mercury Planetary Orbiter).

    NASA Astrophysics Data System (ADS)

    Iafolla, V.; Fiorenza, E.; Lucchesi, D.; Milyukov, V.; Nozzoli, S.

    The RadioScience experiments proposed for the BepiClombo ESA CORNERSTONE are aiming at performing planetary measurements such as: the rotation state of Mer- cury, the global structure of its gravity field and the local gravitational anomalies, but also to test some aspects of the General Relativity, to an unprecedented level of accu- racy. A high sensitivity accelerometer will measure the inertial acceleration acting on the MPO; these data, together with tracking data are used to evaluate the purely gravi- tational trajectory of the MPO, by transforming it to a virtual drag-free satellite system. At the Istituto di Fisica dello Spazio Interplanetario (IFSI) a high sensitive accelerom- eter named ISA (Italian Spring Accelerometer)* and considered for this mission has been studied. The main problems concerning the use of the accelerometer are related to the high dynamics necessary to follow the variation of the acceleration signals, with accuracy equal to 10^-9 g/sqr(Hz), and very high at the MPO orbital period and due to thermal noise introduced at the sidereal period of Mercury. The description of the accelerometer will be presented, with particular attention to the thermal problems and to the analysis regarding the choice of the mounting position on the MPO. *Project funded by the Italian Space Agency (ASI).

  3. Adaptive Observations At Ncep: Past, Present, and Future

    NASA Astrophysics Data System (ADS)

    Toth, Z.; Szunyogh, I.; Bishop, C.; Majumdar, S.; Moskaitis, J.; Lord, S.

    The RadioScience experiments proposed for the BepiClombo ESA CORNERSTONE are aiming at performing planetary measurements such as: the rotation state of Mer- cury, the global structure of its gravity field and the local gravitational anomalies, but also to test some aspects of the General Relativity, to an unprecedented level of accu- racy. A high sensitivity accelerometer will measure the inertial acceleration acting on the MPO; these data, together with tracking data are used to evaluate the purely gravi- tational trajectory of the MPO, by transforming it to a virtual drag-free satellite system. At the Istituto di Fisica dello Spazio Interplanetario (IFSI) a high sensitive accelerom- eter named ISA (Italian Spring Accelerometer)* and considered for this mission has been studied. The main problems concerning the use of the accelerometer are related to the high dynamics necessary to follow the variation of the acceleration signals, with accuracy equal to 10^-9 g/sqr(Hz), and very high at the MPO orbital period and due to thermal noise introduced at the sidereal period of Mercury. The description of the accelerometer will be presented, with particular attention to the thermal problems and to the analysis regarding the choice of the mounting position on the MPO. *Project funded by the Italian Space Agency (ASI).

  4. Developmental Test of the Honeywell Laser Inertial Navigation System (LINS)

    DTIC Science & Technology

    1975-11-01

    The ISA contains three Systron Donner 4841F-10 single axis accelerometers and three Honeywell GG1300- AEOI laser gyros in an orthogonal strapdown...DIAG.1,kM AN.D PHYSICAL CHARACTERISTICS The GG1300- AEOI laser gyro, shown schematically in Figure 2, has the following performance goals which were

  5. Micromachined force-balance feedback accelerometer with optical displacement detection

    DOEpatents

    Nielson, Gregory N.; Langlois, Eric; Baker, Michael; Okandan, Murat; Anderson, Robert

    2014-07-22

    An accelerometer includes a proof mass and a frame that are formed in a handle layer of a silicon-on-an-insulator (SOI). The proof mass is separated from the frame by a back-side trench that defines a boundary of the proof mass. The accelerometer also includes a reflector coupled to a top surface of the proof mass. An optical detector is located above the reflector at the device side. The accelerometer further includes at least one suspension spring. The suspension spring has a handle anchor that extends downwards from the device side to the handle layer to mechanically support upward and downward movement of the proof mass relative to a top surface of the proof mass.

  6. A Low Frequency FBG Accelerometer with Symmetrical Bended Spring Plates.

    PubMed

    Liu, Fufei; Dai, Yutang; Karanja, Joseph Muna; Yang, Minghong

    2017-01-22

    To meet the requirements for low-frequency vibration monitoring, a new type of FBG (fiber Bragg grating) accelerometer with a bended spring plate is proposed. Two symmetrical bended spring plates are used as elastic elements, which drive the FBG to produce axial strains equal in magnitude but opposite in direction when exciting vibrations exist, leading to doubling the wavelength shift of the FBG. The mechanics model and a numerical method are presented in this paper, with which the influence of the structural parameters on the sensitivity and the eigenfrequency are discussed. The test results show that the sensitivity of the accelerometer is more than 1000 pm/g when the frequency is within the 0.7-20 Hz range.

  7. Combining global positioning system and accelerometer data to determine the locations of physical activity in children.

    PubMed

    Oreskovic, Nicolas M; Blossom, Jeff; Field, Alison E; Chiang, Sylvia R; Winickoff, Jonathan P; Kleinman, Ronald E

    2012-05-01

    National trends indicate that children and adolescents are not achieving sufficient levels of physical activity. Combining global positioning system (GPS) technology with accelerometers has the potential to provide an objective determination in locations where youth engage in physical activity. The aim of this study was to identify the optimal methods for collecting combined accelerometer and GPS data in youth, to best locate where children spend time and are physically active. A convenience sample of 24 mid-school children in Massachusetts was included. Accelerometers and GPS units were used to quantify and locate childhood physical activity over 5 weekdays and 2 weekend days. Accelerometer and GPS data were joined by time and mapped with a geographical information system (GIS) using ArcGIS software. Data were collected in winter, spring, summer in 2009-2010, collecting a total of 26,406 matched datapoints overall. Matched data yield was low (19.1% total), regardless of season (winter, 12.8%; spring, 30.1%; summer, 14.3%). Teacher-provided, pre-charged equipment yielded the most matched (30.1%; range: 10.1-52.3%) and greatest average days (6.1 days) of data. Across all seasons, children spent most of their time at home. Outdoor use patterns appeared to vary by season, with street use increasing in spring, and park and playground use increasing in summer. Children spent equal amounts of physical activity time at home and walking in the streets. Overall, the various methods for combining GPS and accelerometer data provided similarly low amounts of combined data. No combined GPS and accelerometer data collection method proved superior in every data return category, but use of GIS to map joined accelerometer and GPS data can demarcate childhood physical activity locations.

  8. Progress Toward a Bulk Micromachined Tunneling Tip Microaccelerometer

    NASA Technical Reports Server (NTRS)

    Frank T. Hartley, Ben Dolgen, Paul M. Zavracky

    1995-01-01

    Ultrasensitive accelerometers are needed for microgravity measurement of orbital drag and active isolation systems. We have designed an accelerometer capable of measuring accelerations of the order of 10(i) g. A tunneling tip sensor can be used as a position sensor with a potential performance advantage of two orders of magnitude over capacitive sensors. In this paper, we disclose our progress in the fabrication and measurement of a bulk microaccelerometer which employs a tunneling tip. Fully assembled accelerometers consisting of four separate die have been fabricated. The device employs a unique folded spring system with a low spring constant. To protect the tunneling tip, we have employed electrostatic clamping. Stiction has not been observed, but the required clamping voltage is greater than expected. We have developed a simple model to analyze our results.

  9. A Subnano-g Electrostatic Force-Rebalanced Flexure Accelerometer for Gravity Gradient Instruments.

    PubMed

    Yan, Shitao; Xie, Yafei; Zhang, Mengqi; Deng, Zhongguang; Tu, Liangcheng

    2017-11-18

    A subnano-g electrostatic force-rebalanced flexure accelerometer is designed for the rotating accelerometer gravity gradient instrument. This accelerometer has a large proof mass, which is supported inversely by two pairs of parallel leaf springs and is centered between two fixed capacitor plates. This novel design enables the proof mass to move exactly along the sensitive direction and exhibits a high rejection ratio at its cross-axis directions. Benefiting from large proof mass, high vacuum packaging, and air-tight sealing, the thermal Brownian noise of the accelerometer is lowered down to less than 0.2 ng / Hz with a quality factor of 15 and a natural resonant frequency of about 7.4 Hz . The accelerometer's designed measurement range is about ±1 mg. Based on the correlation analysis between a commercial triaxial seismometer and our accelerometer, the demonstrated self-noise of our accelerometers is reduced to lower than 0.3 ng / Hz over the frequency ranging from 0.2 to 2 Hz, which meets the requirement of the rotating accelerometer gravity gradiometer.

  10. A Subnano-g Electrostatic Force-Rebalanced Flexure Accelerometer for Gravity Gradient Instruments

    PubMed Central

    Yan, Shitao; Xie, Yafei; Zhang, Mengqi; Deng, Zhongguang

    2017-01-01

    A subnano-g electrostatic force-rebalanced flexure accelerometer is designed for the rotating accelerometer gravity gradient instrument. This accelerometer has a large proof mass, which is supported inversely by two pairs of parallel leaf springs and is centered between two fixed capacitor plates. This novel design enables the proof mass to move exactly along the sensitive direction and exhibits a high rejection ratio at its cross-axis directions. Benefiting from large proof mass, high vacuum packaging, and air-tight sealing, the thermal Brownian noise of the accelerometer is lowered down to less than 0.2 ng/Hz with a quality factor of 15 and a natural resonant frequency of about 7.4 Hz. The accelerometer’s designed measurement range is about ±1 mg. Based on the correlation analysis between a commercial triaxial seismometer and our accelerometer, the demonstrated self-noise of our accelerometers is reduced to lower than 0.3 ng/Hz over the frequency ranging from 0.2 to 2 Hz, which meets the requirement of the rotating accelerometer gravity gradiometer. PMID:29156587

  11. Legends in Learning

    ERIC Educational Resources Information Center

    Lepore, Marla

    2012-01-01

    When ISA-The Association of Learning Providers honored its "First Generation Legends" at its Annual Business Retreat this past spring, it was a gathering of some of the Who's Who of the learning industry. In this article, ten of the training industry's most successful professionals reveal their success drivers and talk about how to effectively…

  12. GLOBE students, teachers, and scientists demonstrate variable differences between urban and rural leaf phenology

    Treesearch

    Rico Gazal; Michael A. White; Robert Gillies; Eli Rodemakers; Elena Sparrow; Leslie Gordon

    2008-01-01

    The urban heat island effect, classically associated with high impervious surface area (ISA), low vegetation fractional cover (Fr), and high land surface temperature (LST), has been linked to changing patterns of vegetation phenology, especially spring growth. In this study, a collaboration with the Global Learning and Observations to Benefit the Environment (GLOBE)...

  13. A simple accurate chest-compression depth gauge using magnetic coils during cardiopulmonary resuscitation

    NASA Astrophysics Data System (ADS)

    Kandori, Akihiko; Sano, Yuko; Zhang, Yuhua; Tsuji, Toshio

    2015-12-01

    This paper describes a new method for calculating chest compression depth and a simple chest-compression gauge for validating the accuracy of the method. The chest-compression gauge has two plates incorporating two magnetic coils, a spring, and an accelerometer. The coils are located at both ends of the spring, and the accelerometer is set on the bottom plate. Waveforms obtained using the magnetic coils (hereafter, "magnetic waveforms"), which are proportional to compression-force waveforms and the acceleration waveforms were measured at the same time. The weight factor expressing the relationship between the second derivatives of the magnetic waveforms and the measured acceleration waveforms was calculated. An estimated-compression-displacement (depth) waveform was obtained by multiplying the weight factor and the magnetic waveforms. Displacements of two large springs (with similar spring constants) within a thorax and displacements of a cardiopulmonary resuscitation training manikin were measured using the gauge to validate the accuracy of the calculated waveform. A laser-displacement detection system was used to compare the real displacement waveform and the estimated waveform. Intraclass correlation coefficients (ICCs) between the real displacement using the laser system and the estimated displacement waveforms were calculated. The estimated displacement error of the compression depth was within 2 mm (<1 standard deviation). All ICCs (two springs and a manikin) were above 0.85 (0.99 in the case of one of the springs). The developed simple chest-compression gauge, based on a new calculation method, provides an accurate compression depth (estimation error < 2 mm).

  14. Evaluation of Thermo-Mechanical Stability of COTS Dual-Axis MEMS Accelerometers for Space Applications

    NASA Technical Reports Server (NTRS)

    Sharma, Ashok K.; Teverovksy, Alexander; Day, John H. (Technical Monitor)

    2000-01-01

    Microelectromechanical systems in MEMS is one of the fastest growing technologies in microelectronics, and is of great interest for military and aerospace applications. Accelerometers are the earliest and most developed representatives of MEMS. First demonstrated in 1979, micromachined accelerometers were used in automobile industry for air bag crash- sensing applications since 1990. In 1999, N4EMS accelerometers were used in NASA-JPL Mars Microprobe. The most developed accelerometers for airbag crash- sensing are rated for a full range of +/- 50 G. The range of sensitivity for accelerometers required for military or aerospace applications is much larger, varying from 20,000 G (to measure acceleration during gun and ballistic munition launches), and to 10(exp -6) G, when used as guidance sensors (to measure attitude and position of a spacecraft). The presence of moving parts on the surface of chip is specific to MEMS, and particularly, to accelerometers. This characteristic brings new reliability issues to micromachined accelerometers, including cyclic fatigue cracking of polysilicon cantilevers and springs, mechanical stresses that are caused by packaging and contamination in the internal cavity of the package. Studies of fatigue cracks initiation and growth in polysilicon showed that the fatigue damage may influence MEMS device performance, and the presence of water vapor significantly enhances crack initiation and growth. Environmentally induced failures, particularly, failures due to thermal cycling and mechanical shock are considered as one of major reliability concerns in MEMS. These environmental conditions are also critical for space applications of the parts. For example, the Mars pathfinder mission had experienced 80 mechanical shock events during the pyrotechnic separation processes.

  15. Electret accelerometers: physics and dynamic characterization.

    PubMed

    Hillenbrand, J; Haberzettl, S; Motz, T; Sessler, G M

    2011-06-01

    Electret microphones are produced in numbers that significantly exceed those for all other microphone types. This is due to the fact that air-borne electret sensors are of simple and low-cost design but have very good acoustical properties. In contrast, most of the discrete structure-borne sound sensors (or accelerometers) are based on the piezoelectric effect. In the present work, capacitive accelerometers utilizing the electret principle were constructed, built, and characterized. These electret accelerometers comprise a metallic seismic mass, covered by an electret film, a ring of a soft cellular polymer supplying the restoring force, and a metallic backplate. These components replace membrane, spacer, and back electrode, respectively, of the electret microphone. An adjustable static pressure to the seismic mass is generated by two metal springs. The dynamic characterization of the accelerometers was carried out by using an electrodynamic shaker and an external charge or voltage amplifier. Sensors with various seismic masses, air gap distances, and electret voltages were investigated. Charge sensitivities from 10 to 40 pC/g, voltage sensitivities from 600 to 2000 mV/g, and resonance frequencies from 3 to 1.5 kHz were measured. A model describing both the charge and the voltage sensitivity is presented. Good agreement of experimental and calculated values is found. The experimental results show that sensitive, lightweight, and inexpensive electret accelerometers can be built. © 2011 Acoustical Society of America

  16. Temperature insensitive all-fiber accelerometer using a photonic crystal fiber long-period grating interferometer

    NASA Astrophysics Data System (ADS)

    Zheng, Shijie; Zhu, Yinian; Krishnaswamy, Sridhar

    2012-04-01

    Fiber-optic accelerometers have attracted great attention in recent years due to the fact that they have many advantages over electrical counterparts because all-fiber accelerometers have the capabilities for multiplexing to reduce cabling and to transmit signals over a long distance. They are also immune to electromagnetic interference. We propose and develop a compact and robust photonic crystal fiber (PCF) Mach-Zehnder interferometer (MZI) that can be implemented as an accelerometer for measurements of vibration and displacement. To excite core mode to couple out with cladding modes, two long-period gratings (LPGs) with identical transmission spectra are needed to be written in an endless single-mode PCF using a CO2 laser. The first LPG can couple a part of core mode to several cladding modes. After the light beams travel at different speeds over a certain length of the core and cladding, the cladding modes will be recoupled back to the core when they meet the second LPG, resulting in interference between the core mode and cladding modes. Dynamic strain is introduced to the PCF-MZI fiber segment that is bonded onto a spring-mass system. The shift of interference fringe can be measured by a photodetector, and the transformed analog voltage signal is proportional to the acceleration of the sensor head. Based on simulations of the PCF-MZI accelerometer, we can get a sensitivity of ~ 0.08 nm/g which is comparable with fiber Bragg grating (FBG) accelerometers. The proposed accelerometer has a capability of temperature insensitivity; therefore, no thermal-compensation scheme is required. Experimental results indicate that the PCF-MZI accelerometer may be a good candidate sensor for applications in civil engineering infrastructure and aeronautical platforms.

  17. Multiple-stage integrating accelerometer

    DOEpatents

    Devaney, H.F.

    1984-06-27

    An accelerometer assembly is provided for use in activating a switch in response to multiple acceleration pulses in series. The accelerometer includes a housing forming a chamber. An inertial mass or piston is slidably disposed in the chamber and spring biased toward a first or reset position. A damping system is also provided to damp piston movement in response to first and subsequent acceleration pulses. Additionally, a cam, including a Z-shaped slot, and cooperating follower pin slidably received therein are mounted to the piston and the housing. The middle or cross-over leg of the Z-shaped slot cooperates with the follower pin to block or limit piston movement and prevent switch activation in response to a lone acceleration pulse. The switch of the assembly is only activated after two or more separate acceleration pulses are sensed and the piston reaches the end of the chamber opposite the reset position.

  18. Function of isoamylase-type starch debranching enzymes ISA1 and ISA2 in the Zea mays leaf.

    PubMed

    Lin, Qiaohui; Facon, Maud; Putaux, Jean-Luc; Dinges, Jason R; Wattebled, Fabrice; D'Hulst, Christophe; Hennen-Bierwagen, Tracie A; Myers, Alan M

    2013-12-01

    Conserved isoamylase-type starch debranching enzymes (ISAs), including the catalytic ISA1 and noncatalytic ISA2, are major starch biosynthesis determinants. Arabidopsis thaliana leaves require ISA1 and ISA2 for physiological function, whereas endosperm starch is near normal with only ISA1. ISA functions were characterized in maize (Zea mays) leaves to determine whether species-specific distinctions in ISA1 primary structure, or metabolic differences in tissues, are responsible for the differing ISA2 requirement. Genetic methods provided lines lacking ISA1 or ISA2. Biochemical analyses characterized ISA activities in mutant tissues. Starch content, granule morphology, and amylopectin fine structure were determined. Three ISA activity forms were observed in leaves, two ISA1/ISA2 heteromultimers and one ISA1 homomultimer. ISA1 homomultimer activity existed in mutants lacking ISA2. Mutants without ISA2 differed in leaf starch content, granule morphology, and amylopectin structure compared with nonmutants or lines lacking both ISA1 and ISA2. The data imply that both the ISA1 homomultimer and ISA1/ISA2 heteromultimer function in the maize leaf. The ISA1 homomultimer is present and functions in the maize leaf. Evolutionary divergence between monocots and dicots probably explains the ability of ISA1 to function as a homomultimer in maize leaves, in contrast to other species where the ISA1/ISA2 heteromultimer is the only active form. No claim to original US goverment works. New Phytologist © 2013 New Phytologist Trust.

  19. Short poster presentations

    NASA Astrophysics Data System (ADS)

    Cremonese, Gabriele

    I.Holin, core-mantle interplay from spin variation of Mercury's crust G.Murakami et al., de-velopment of the microchannel plate detector for fuv spectroscopy in the bepicolombo mission K.Yoshioka et al., performance of the euv detector of phebus for the bepicolombo mission L.Ksanfomality, large dark area on Mercury neighboring the s basin L.Czechowsk,delamination of the lithosphere and similar processes in terrestrial planets R.Ziethe, Mercury's thermal evo-lution, dynamical topography and geoid S.Ferrari et al., geo-structural mapping and age de-terminations of Rembrandt basin F.Nestola et al., low-high temperature behaviour of olivine: implication for Mercury surface M.Blecka, influence the temperatures of the surface and gaseous environment of Mercury on ir radiance spectra -the results of numerical simulation V.Iafolla et al., contributions of isa accelerometer to bepicolombo exploration of planet mercury Y.Miyake et al., particle-in-cell analysis of an electric antenna for the bepicolombo/mmo spacecraft

  20. Physical activity levels of community-dwelling older adults are influenced by winter weather variables.

    PubMed

    Jones, G R; Brandon, C; Gill, D P

    2017-07-01

    Winter weather conditions may negatively influence participation of older adults in daily physical activity (PA). Assess the influence of winter meteorological variables, day-time peak ambient temperature, windchill, humidity, and snow accumulation on the ground to accelerometer measured PA values in older adults. 50 community-dwelling older adults (77.4±4.7yrs; range 71-89; 12 females) living in Southwestern Ontario (Latitude 42.9°N Longitude 81.2° W) Canada, wore a waist-borne accelerometer during active waking hours (12h) for 7 consecutive days between February and April 2007. Hourly temperature, windchill, humidity, and snowfall accumulation were obtained from meteorological records and time locked to hourly accelerometer PA values. Regression analysis revealed significant relationships between time of day, ambient daytime high temperature and a humidity for participation in PA. Windchill temperature added no additional influence over PA acclamation already influenced by ambient day-time temperature and the observed variability in PA patterns relative to snow accumulation over the study period was too great to warrant its inclusion in the model. Most PA was completed in the morning hours and increased as the winter month's transitioned to spring (February through April). An equation was developed to adjust for winter weather conditions using temperature, humidity and time of day. Accurate PA assessment during the winter months must account for the ambient daytime high temperatures, humidity, and time of day. These older adults were more physically active during the morning hours and became more active as the winter season transitioned to spring. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. NASA Ultra-Sensitive Miniature Accelerometer

    NASA Technical Reports Server (NTRS)

    Zavracky, Paul M.; Hartley, Frank T.

    1994-01-01

    Using micro-machined silicon technology, an ultra-sensitive miniature acce.,rometer can be constructed which meets the requirements for microgravity experiments in the space environment.Such an accelerometer will have a full scale sensitivity of 1C2 g a resolution of lC8 g, low cross axis sensitivity, and low temperature sensitivity. Mass of the device is approximately five grams and its footprint is 2 cm x 2 cm. Innovative features of the accelerometer, which are patented, are: electrostatic caging to withstand handling shock up to 150 g, in-situ calibration, in situ performance characterization, and both static and dynamic compensation. The transducer operates on a force balance principle wherein the displacement of the proof mass is monitored by measuring tunneling electron current flow between a conductive tip, and a fixed platen. The four major parts of the accelerometer are tip die, incorporating the tunneling tip and four field plates for controlling pitch and roll of the proof mass; two proof mass dies, attached to the surrounding frame by sets of four leg" springs; and a force plate die. The four parts are fuse-bonded into a complete assembly. External electrical connections are made at bond pads on the front surface of the force plate die. Materials and processes used in the construction of the transducer are compatible with volume production.

  2. Functional Diversity of Isoamylase Oligomers: The ISA1 Homo-Oligomer Is Essential for Amylopectin Biosynthesis in Rice Endosperm1[W][OA

    PubMed Central

    Utsumi, Yoshinori; Utsumi, Chikako; Sawada, Takayuki; Fujita, Naoko; Nakamura, Yasunori

    2011-01-01

    Rice (Oryza sativa) endosperm has two isoamylase (ISA) oligomers, ISA1 homo-oligomer and ISA1-ISA2 hetero-oligomer. To examine their contribution to starch synthesis, expression of the ISA1 or ISA2 gene was differently regulated in various transgenic plants. Although suppression of ISA2 gene expression caused the endosperm to have only the homo-oligomer, no significant effects were detected on the starch phenotypes. In contrast, ISA2 overexpression led to endosperm having only the hetero-oligomer, and starch synthesis in the endosperm was drastically impaired, both quantitatively and qualitatively, because the starch was devoid of typical starch features, such as thermal and x-ray diffraction properties, and water-soluble highly branched maltodextrins were accumulated. In the ISA2 overexpressed line, about 60% to 70% of the ISA1-ISA2 hetero-oligomer was bound to starch, while the ISA homo- and hetero-oligomers from the wild type were mostly present in the soluble form at the early milking stage of the endosperm. Detailed analysis of the relative amounts of homo- and hetero-oligomers in various lines also led us to the conclusion that the ISA1 homo-oligomer is essential, but not the ISA1-ISA2 oligomer, for starch production in rice endosperm. The relative amounts of ISA1 and ISA2 proteins were shown to determine the ratio of both oligomers and the stoichiometry of both ISAs in the hetero-oligomer. It was noted when compared with the homo-oligomer that all the hetero-oligomers from rice endosperm and leaf and potato (Solanum tuberosum) tuber were much more stable at 40°C. This study provides substantial data on the structural and functional diversity of ISA oligomers between plant tissues and species. PMID:21436381

  3. Evaluation of Montanide™ ISA 71 VG Adjuvant during Profilin Vaccination against Experimental Coccidiosis

    PubMed Central

    Lillehoj, Hyun S.; Lee, Sung Hyen; Lee, Kyung Woo; Bertrand, François; Dupuis, Laurent; Deville, Sébastien; Ben Arous, Juliette; Lillehoj, Erik P.

    2013-01-01

    Chickens were immunized subcutaneously with an Eimeria recombinant profilin protein plus Montanide™ ISA 70 VG (ISA 70) or Montanide™ ISA 71 VG (ISA 71) water-in-oil adjuvants, or with profilin alone, and comparative RNA microarray hybridizations were performed to ascertain global transcriptome changes induced by profilin/ISA 70 vs. profilin alone and by profilin/ISA 71 vs. profilin alone. While immunization with profilin/ISA 70 vs. profilin alone altered the levels of more total transcripts compared with profilin/ISA 71 vs. profilin alone (509 vs. 296), the latter was associated with a greater number of unique biological functions, and a larger number of genes within these functions, compared with the former. Further, canonical pathway analysis identified 10 pathways that were associated with genes encoding the altered transcripts in animals immunized with profilin/ISA 71 vs. profilin alone, compared with only 2 pathways in profilin/ISA 70 vs. profilin alone. Therefore, ISA 71 was selected as a candidate adjuvant in conjunction with profilin vaccination for in vivo disease protection studies. Vaccination with profilin/ISA 71 was associated with greater body weight gain following E. acervulina infection, and decreased parasite fecal shedding after E. maxima infection, compared with profilin alone. Anti-profilin antibody levels were higher in sera of E. maxima- and E. tenella-infected chickens vaccinated with profilin/ISA 71 compared with profilin alone. Finally, the levels of transcripts encoding interferon-γ, interleukin (IL)-2, IL-10, and IL-17A were increased in intestinal lymphocytes from E. acervulina-, E. maxima-, and/or E. tenella-infected chickens vaccinated with profilin/ISA 71 compared with profilin alone. None of these effects were seen in chickens injected with ISA 71 alone indicating that the adjuvant was not conferring non-specific immune stimulation. These results suggest that profilin plus ISA 71 augments protective immunity against selective Eimeria species in chickens. PMID:23593150

  4. High resolution space quartz-flexure accelerometer based on capacitive sensing and electrostatic control technology.

    PubMed

    Tian, W; Wu, S C; Zhou, Z B; Qu, S B; Bai, Y Z; Luo, J

    2012-09-01

    High precision accelerometer plays an important role in space scientific and technical applications. A quartz-flexure accelerometer operating in low frequency range, having a resolution of better than 1 ng/Hz(1/2), has been designed based on advanced capacitive sensing and electrostatic control technologies. A high precision capacitance displacement transducer with a resolution of better than 2 × 10(-6) pF/Hz(1/2) above 0.1 Hz, is used to measure the motion of the proof mass, and the mechanical stiffness of the spring oscillator is compensated by adjusting the voltage between the proof mass and the electrodes to induce a proper negative electrostatic stiffness, which increases the mechanical sensitivity and also suppresses the position measurement noise down to 3 × 10(-10) g/Hz(1/2) at 0.1 Hz. A high resolution analog-to-digital converter is used to directly readout the feedback voltage applied on the electrodes in order to suppress the action noise to 4 × 10(-10) g/Hz(1/2) at 0.1 Hz. A prototype of the quartz-flexure accelerometer has been developed and tested, and the preliminary experimental result shows that its resolution comes to about 8 ng/Hz(1/2) at 0.1 Hz, which is mainly limited by its mechanical thermal noise due to low quality factor.

  5. Impacts of monetary incentive measures on the acceptability for intelligent speed adaptation (ISA)

    NASA Astrophysics Data System (ADS)

    Matsuo, Kojiro; Sugihara, Mitsuru; Yamazaki, Motohiro; Mimura, Yasuhiro; Kanno, Komei; Sugiki, Nao

    2017-10-01

    In Japan, Mandatory Intelligent Speed Adaptation (ISA) or Voluntary ISA could be a new paradigm for urban driving speed management such as traffic calming in community streets, once it is widely disseminated. This study aims to analyze the impacts of various monetary incentive measures and individual attributes on the acceptability for several ISA installation. We conducted a stated preference (SP) surveys for the subjects who had attended in a 5-month Advisory ISA field experiment. Then we applied disaggregate model analyses to the response data. The main results were: that the acceptability for Advisory ISA is highest followed by Voluntary ISA and then Mandatory ISA; that the acceptability for ISA that operates only on community streets is high; that the acceptability becomes higher as the age of the subjects becomes higher; and that the acceptability becomes higher as the amount of the monetary incentive becomes greater, but the marginal effect becomes lower. In conclusions, the monetary incentive measures for disseminating Voluntary ISA seems to be practical.

  6. Evaluation of Montanide ISA 71 VG adjuvant during profilin vaccination against experimental coccidiosis

    USDA-ARS?s Scientific Manuscript database

    Chickens were immunized subcutaneously with an Eimeria recombinant profilin protein plus ISA 70 VG (ISA 70) or ISA 71 VG (ISA 71) water-in-oil adjuvants, or with profilin alone, and comparative RNA microarray hybridizations were performed to ascertain global transcriptome changes induced by profilin...

  7. mzML2ISA & nmrML2ISA: generating enriched ISA-Tab metadata files from metabolomics XML data

    PubMed Central

    Larralde, Martin; Lawson, Thomas N.; Weber, Ralf J. M.; Moreno, Pablo; Haug, Kenneth; Rocca-Serra, Philippe; Viant, Mark R.; Steinbeck, Christoph; Salek, Reza M.

    2017-01-01

    Abstract Summary Submission to the MetaboLights repository for metabolomics data currently places the burden of reporting instrument and acquisition parameters in ISA-Tab format on users, who have to do it manually, a process that is time consuming and prone to user input error. Since the large majority of these parameters are embedded in instrument raw data files, an opportunity exists to capture this metadata more accurately. Here we report a set of Python packages that can automatically generate ISA-Tab metadata file stubs from raw XML metabolomics data files. The parsing packages are separated into mzML2ISA (encompassing mzML and imzML formats) and nmrML2ISA (nmrML format only). Overall, the use of mzML2ISA & nmrML2ISA reduces the time needed to capture metadata substantially (capturing 90% of metadata on assay and sample levels), is much less prone to user input errors, improves compliance with minimum information reporting guidelines and facilitates more finely grained data exploration and querying of datasets. Availability and Implementation mzML2ISA & nmrML2ISA are available under version 3 of the GNU General Public Licence at https://github.com/ISA-tools. Documentation is available from http://2isa.readthedocs.io/en/latest/. Contact reza.salek@ebi.ac.uk or isatools@googlegroups.com Supplementary information Supplementary data are available at Bioinformatics online. PMID:28402395

  8. mzML2ISA & nmrML2ISA: generating enriched ISA-Tab metadata files from metabolomics XML data.

    PubMed

    Larralde, Martin; Lawson, Thomas N; Weber, Ralf J M; Moreno, Pablo; Haug, Kenneth; Rocca-Serra, Philippe; Viant, Mark R; Steinbeck, Christoph; Salek, Reza M

    2017-08-15

    Submission to the MetaboLights repository for metabolomics data currently places the burden of reporting instrument and acquisition parameters in ISA-Tab format on users, who have to do it manually, a process that is time consuming and prone to user input error. Since the large majority of these parameters are embedded in instrument raw data files, an opportunity exists to capture this metadata more accurately. Here we report a set of Python packages that can automatically generate ISA-Tab metadata file stubs from raw XML metabolomics data files. The parsing packages are separated into mzML2ISA (encompassing mzML and imzML formats) and nmrML2ISA (nmrML format only). Overall, the use of mzML2ISA & nmrML2ISA reduces the time needed to capture metadata substantially (capturing 90% of metadata on assay and sample levels), is much less prone to user input errors, improves compliance with minimum information reporting guidelines and facilitates more finely grained data exploration and querying of datasets. mzML2ISA & nmrML2ISA are available under version 3 of the GNU General Public Licence at https://github.com/ISA-tools. Documentation is available from http://2isa.readthedocs.io/en/latest/. reza.salek@ebi.ac.uk or isatools@googlegroups.com. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  9. Spaceborne Gravity Gradiometers. Part 3: Instrument status and prospects

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Various technologies incorporated in the development of gravity gradiometers are demonstrated through descriptions of specific instruments. Concepts covered include: rotating, spherical, cryogenic, and superconducting gravity gradiometers with and without accelerometers. The application of superconducting cavity oscillators to mass-spring gradiometers, and cooperation of Italy's Piano Spaziale Nazionale with the Smithsonian Astrophysics Observatory in the design and development of a high sensitivity gradiometer are described. Schematics are provided for each instrument.

  10. linkedISA: semantic representation of ISA-Tab experimental metadata.

    PubMed

    González-Beltrán, Alejandra; Maguire, Eamonn; Sansone, Susanna-Assunta; Rocca-Serra, Philippe

    2014-01-01

    Reporting and sharing experimental metadata- such as the experimental design, characteristics of the samples, and procedures applied, along with the analysis results, in a standardised manner ensures that datasets are comprehensible and, in principle, reproducible, comparable and reusable. Furthermore, sharing datasets in formats designed for consumption by humans and machines will also maximize their use. The Investigation/Study/Assay (ISA) open source metadata tracking framework facilitates standards-compliant collection, curation, visualization, storage and sharing of datasets, leveraging on other platforms to enable analysis and publication. The ISA software suite includes several components used in increasingly diverse set of life science and biomedical domains; it is underpinned by a general-purpose format, ISA-Tab, and conversions exist into formats required by public repositories. While ISA-Tab works well mainly as a human readable format, we have also implemented a linked data approach to semantically define the ISA-Tab syntax. We present a semantic web representation of the ISA-Tab syntax that complements ISA-Tab's syntactic interoperability with semantic interoperability. We introduce the linkedISA conversion tool from ISA-Tab to the Resource Description Framework (RDF), supporting mappings from the ISA syntax to multiple community-defined, open ontologies and capitalising on user-provided ontology annotations in the experimental metadata. We describe insights of the implementation and how annotations can be expanded driven by the metadata. We applied the conversion tool as part of Bio-GraphIIn, a web-based application supporting integration of the semantically-rich experimental descriptions. Designed in a user-friendly manner, the Bio-GraphIIn interface hides most of the complexities to the users, exposing a familiar tabular view of the experimental description to allow seamless interaction with the RDF representation, and visualising descriptors to drive the query over the semantic representation of the experimental design. In addition, we defined queries over the linkedISA RDF representation and demonstrated its use over the linkedISA conversion of datasets from Nature' Scientific Data online publication. Our linked data approach has allowed us to: 1) make the ISA-Tab semantics explicit and machine-processable, 2) exploit the existing ontology-based annotations in the ISA-Tab experimental descriptions, 3) augment the ISA-Tab syntax with new descriptive elements, 4) visualise and query elements related to the experimental design. Reasoning over ISA-Tab metadata and associated data will facilitate data integration and knowledge discovery.

  11. Heterologous co-expression in E. coli of isoamylase genes from cassava Manihot esculenta Crantz 'KU50' achieves enzyme-active heteromeric complex formation.

    PubMed

    Panpetch, Pawinee; Field, Robert A; Limpaseni, Tipaporn

    2018-03-01

    Cloning of two isoamylase genes, MeISA1 and MeISA2, from cassava (Manihot esculenta Crantz) tubers, accompanied by their co-expression in E. coli demonstrates a requirement for heteromeric complex formation to achieve debranching activity. Starch debranching enzyme (DBE) or isoamylase (ISA) (EC.3.2.1.68), an important enzyme in starch metabolism, catalyses the hydrolysis of α-1,6 glycosidic linkages of amylopectin. Isoforms of ISAs have been reported in higher plants and algae (Fujita et al. in Planta 208:283-293, 1999; Hussain et al. in Plant Cell 15:133-149, 2003; Ishizaki et al. in Agric Biol Chem 47:771-779, 1983; Mouille et al. in Plant Cell 8:1353-1366, 1996). In the current work, cassava ISA genes were isolated from cDNA generated from total RNA from tubers of Manihot esculanta Crantz cultivar KU50. MeISA1 and MeISA2 were successfully amplified and cloned into a pETDuet1 vector. The putative MeISA1 and MeISA2 proteins comprised 763 and 882 amino acids, with substantial similarity to StISA1 and StISA2 from potato (84.4% and 68.9%, respectively). Recombinant MeISA1 and MeISA2 were co-expressed in Escherichia coli SoluBL21 (DE3). Histrap TM -Purified rMeISA1 and rMeISA2 showed approximate molecular weights of 87 and 99 kDa, respectively, by SDS-PAGE. Debranching activity was only detectable in the column fractions where both recombinant ISA isoforms were present. The heteromeric DBE from crude extracts of 4-5 h induced cultures analysed by gel filtration chromatography and western blot showed combinations of rMeISA1 and rMeISA2 at ratios of 1:1 to 4:1. Pooled fractions with DBE activity were used for enzyme characterisation, which showed that the enzyme was specific for amylopectin, with optimum activity at 37 °C and pH 7.0. Enzyme activity was enhanced by Co 2+ , Mg 2+ and Ca 2+ , but was strongly inhibited by Cu 2+ . Debranched amylopectin products showed chain length distributions typical of plant DBE.

  12. Evaluation of Montanide TM ISA 71 VG adjuvant during profilin vaccination against experimental coccidiosis

    USDA-ARS?s Scientific Manuscript database

    Chickens were immunized subcutaneously with an Eimeria recombinant profilin protein plus MontanideTM ISA 70 VG (ISA 70) or MontanideTM ISA 71 VG (ISA 71) water-in-oil adjuvants, or with profilin alone, and comparative RNA microarray analyses were performed to ascertain global transcriptomic changes ...

  13. Active Vibration Isolation of Microgravity Experiments with Spring Umbilicals Using an Electrodynamic Actuator

    NASA Technical Reports Server (NTRS)

    Banerjee, B. B.; Allaire, P. E.; Grodsinsky, C. M.

    1996-01-01

    Microgravity experiments will require active vibration isolation in the low to mid frequency range of 0.1 Hz to 10 Hz. Approximately two orders of acceleration reduction (40 dB) will be required. Previous works have reported results for accelerations transmitted through the umbilical. This paper describes experimental and theoretical results for vibration isolation in one dimension (horizontal) where the simulated experiment is connected to the spacecraft by a spring umbilical. The experiment consisted of a spacecraft (shaker), experiment (mass), umbilical, accelerometer, control electronics, and Lorentz actuator. The experiment mass was supported in magnetic bearings to avoid any stiction problems. Acceleration feedback control was employed to obtain the vibration isolation. Three different spring umbilicals were employed. Acceleration reductions on the order of 40 dB were obtained over the frequency range of 0.1 Hz to 10 Hz. Good agreement was obtained between theory and experiment.

  14. Analysis and design of second-order sliding-mode algorithms for quadrotor roll and pitch estimation.

    PubMed

    Chang, Jing; Cieslak, Jérôme; Dávila, Jorge; Zolghadri, Ali; Zhou, Jun

    2017-11-01

    The problem addressed in this paper is that of quadrotor roll and pitch estimation without any assumption about the knowledge of perturbation bounds when Inertial Measurement Units (IMU) data or position measurements are available. A Smooth Sliding Mode (SSM) algorithm is first designed to provide reliable estimation under a smooth disturbance assumption. This assumption is next relaxed with the second proposed Adaptive Sliding Mode (ASM) algorithm that deals with disturbances of unknown bounds. In addition, the analysis of the observers are extended to the case where measurements are corrupted by bias and noise. The gains of the proposed algorithms were deduced from the Lyapunov function. Furthermore, some useful guidelines are provided for the selection of the observer turning parameters. The performance of these two approaches is evaluated using a nonlinear simulation model and considering either accelerometer or position measurements. The simulation results demonstrate the benefits of the proposed solutions. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions.

    PubMed

    Forner-Cordero, A; Mateu-Arce, M; Forner-Cordero, I; Alcántara, E; Moreno, J C; Pons, J L

    2008-04-01

    A common problem shared by accelerometers, inertial sensors and any motion measurement method based on skin-mounted sensors is the movement of the soft tissues covering the bones. The aim of this work is to propose a method for the validation of the attachment of skin-mounted sensors. A second-order (mass-spring-damper) model was proposed to characterize the behaviour of the soft tissue between the bone and the sensor. Three sets of experiments were performed. In the first one, different procedures to excite the system were evaluated to select an adequate excitation stimulus. In the second one, the selected stimulus was applied under varying attachment conditions while the third experiment was used to test the model. The heel drop was chosen as the excitation method because it showed lower variability and could discriminate between different attachment conditions. There was, in agreement with the model, a trend to increase the natural frequency of the system with decreasing accelerometer mass. An important result is the development of a standard procedure to test the bandwidth of skin-mounted inertial sensors, such as accelerometers mounted on the skin or markers heavier than a few grams.

  16. Replacement of the Endogenous Starch Debranching Enzymes ISA1 and ISA2 of Arabidopsis with the Rice Orthologs Reveals a Degree of Functional Conservation during Starch Synthesis

    PubMed Central

    Streb, Sebastian; Zeeman, Samuel C.

    2014-01-01

    This study tested the interchangeability of enzymes in starch metabolism between dicotyledonous and monocotyledonous plant species. Amylopectin - a branched glucose polymer - is the major component of starch and is responsible for its semi-crystalline property. Plants synthesize starch with distinct amylopectin structures, varying between species and tissues. The structure determines starch properties, an important characteristic for cooking and nutrition, and for the industrial uses of starch. Amylopectin synthesis involves at least three enzyme classes: starch synthases, branching enzymes and debranching enzymes. For all three classes, several enzyme isoforms have been identified. However, it is not clear which enzyme(s) are responsible for the large diversity of amylopectin structures. Here, we tested whether the specificities of the debranching enzymes (ISA1 and ISA2) are major determinants of species-dependent differences in amylopectin structure by replacing the dicotyledonous Arabidopsis isoamylases (AtISA1 and AtISA2) with the monocotyledonous rice (Oryza sativa) isoforms. We demonstrate that the ISA1 and ISA2 are sufficiently well conserved between these species to form heteromultimeric chimeric Arabidopsis/rice isoamylase enzymes. Furthermore, we were able to reconstitute the endosperm-specific rice OsISA1 homomultimeric complex in Arabidopsis isa1isa2 mutants. This homomultimer was able to facilitate normal rates of starch synthesis. The resulting amylopectin structure had small but significant differences in comparison to wild-type Arabidopsis amylopectin. This suggests that ISA1 and ISA2 have a conserved function between plant species with a major role in facilitating the crystallization of pre-amylopectin synthesized by starch synthases and branching enzymes, but also influencing the final structure of amylopectin. PMID:24642810

  17. Pay as You Speed, ISA with incentive for not speeding: results and interpretation of speed data.

    PubMed

    Lahrmann, Harry; Agerholm, Niels; Tradisauskas, Nerius; Berthelsen, Kasper K; Harms, Lisbeth

    2012-09-01

    To simulate a market introduction of Intelligent Speed Adaptation (ISA) and to study the effect of a Pay as You Speed (PAYS) concept, a field trial with 153 drivers was conducted during 2007-2009. The participants drove under PAYS conditions for a shorter or a longer period. The PAYS concept consisted of informative ISA linked with economic incentive for not speeding, measured through automatic count of penalty points whenever the speed limit was exceeded. The full incentive was set to 30% of a participant's insurance premium. The participants were exposed to different treatments, with and without incentive crossed with informative ISA present or absent. The results showed that ISA is an efficient tool for reducing speeding particularly on rural roads. The analysis of speed data demonstrated that the proportion of distance driven above the speed where the ISA equipment responded (PDA) was a sensitive measure for reflecting the effect of ISA, whereas mean free flow speed and the 85th percentile speed, were less sensitive to ISA effects. The PDA increased a little over time but still remained at a low level; however, when ISA was turned off, the participants' speeding relapsed to the baseline level. Both informative ISA and incentive ISA reduced the PDA, but there was no statistically significant interaction. Informative reduced it more than the incentive. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. POD improvements of GALILEO satellites through the measurement of their non-gravitational accelerations by means of an onboard accelerometer

    NASA Astrophysics Data System (ADS)

    Peron, Roberto; Lucchesi, David M.; Santoli, Francesco; Iafolla, Valerio; Fiorenza, Emiliano; Lefevre, Carlo; Lucente, Marco; Magnafico, Carmelo; Kalarus, Maciej; Zielinski, Janusz

    2016-04-01

    The Precise Orbit Determination (POD) of the satellites of the Global Navigation Satellite Systems (GNSS) represents the basic prerequisite in order to provide refined ephemerides for their orbit, aimed at providing a precise and accurate positioning on the Earth. An important factor that impacts negatively in the POD of these satellites is the limited modeling of the accelerations produced by the non-gravitational accelerations. These, indeed, are subtle and generally complex to model properly, especially in the case of a complex in shape spacecraft, with solar panels and antennae for microwave link and the mutual shadowing effects among the many surfaces involved. We have to notice that their modeling has an important impact in the determination of a number of geophysical parameters of interest, such as stations coordinates, Earth's geocenter and orientation parameters. In the case of GNSS satellites, the main NGP acceleration is the one produced by the direct solar radiation pressure, with non-negligible contributions due to Earth's albedo, thermal effects and power radiated by the antennae. The models developed so far for these perturbative effects have shown many limits, as pointed out in the literature. Currently, the models developed for the NGPs are mainly based on empirical blind models (with the goal of absorb unknowns quantities) and more recently with the use of wing-box models, that try to provide a finite-elements approach to the modeling. The European Space Agency (ESA) - in the context of the development of the GALILEO constellation, and especially in view of the next generation of GALILEO spacecraft - besides being interested in possible improvements of the NGPs models, is also envisaging the use of an onboard accelerometer to directly measure them in order to improve the POD of each spacecraft of the constellation. We have been involved in this study by means of a proposal to ESA denominated GALileo and ACcelerometry (GALAC) led by the Space Research Centre (SRC) of the Polish Academy of Sciences (PAS) of Warsaw. The GALAC main objective is to provide the characteristics and performance of an onboard accelerometer able to improve the POD with respect to the current best results obtained through the modeling of the NGPs. The starting point of our activities has been the ISA accelerometer developed for the ESA BepiColombo mission to Mercury. We will present our results of a preparatory work for GALAC concerning a first characterization of the main NGPs acting on the GALILEO spacecraft of second generation, including their (main) spectral content. Such results are used to preliminary fix the accelerometer measurement band, its sensitivity and physical characteristics in order to fit with the GALILEO spacecraft environment.

  19. Extraction and Analysis of Impervious Surfaces Based on a Spectral Un-Mixing Method Using Pearl River Delta of China Landsat TM/ETM+ Imagery from 1998 to 2008

    PubMed Central

    Deng, Yingbin; Fan, Fenglei; Chen, Renrong

    2012-01-01

    Impervious surface area (ISA) is considered as an indicator of environment change and is regarded as an important input parameter for hydrological cycle simulation, water management and area pollution assessment. The Pearl River Delta (PRD), the 3rd most important economic district of China, is chosen in this paper to extract the ISA information based on Landsat images of 1998, 2003 and 2008 by using a linear spectral un-mixing method and to monitor impervious surface change by analyzing the multi-temporal Landsat-derived fractional impervious surface. Results of this study were as follows: (1) the area of ISA in the PRD increased 79.09% from 1998 to 2003 and 26.88% from 2003 to 2008 separately; (2) the spatial distribution of ISA was described according to the 1998/2003 percentage respectively. Most of middle and high percentage ISA was located in northwestern and southeastern of the whole delta, and middle percentage ISA was mainly located in the city interior, high percentage ISA was mainly located in the suburban around the city accordingly; (3) the expanding direction and trend of high percentage ISA was discussed in order to understand the change of urban in this delta; High percentage ISA moved from inner city to edge of urban area during 1998–2003 and moved to the suburban area that far from the urban area mixed with jumpily and gradually during 2003–2008. According to the discussion of high percentage ISA spatial expanded direction, it could be found out that high percentage ISA moved outward from the centre line of Pearl River of the whole delta while a high ISA percentage in both shores of the Pearl River Estuary moved toward the Pearl River; (4) combining the change of ISA with social conditions, the driving relationship was analyzed in detail. It was evident that ISA percentage change had a deep relationship with the economic development of this region in the past ten years. Contemporaneous major sport events (16th Asia Games of Guangzhou, 26th Summer Universidad of Shenzhen) and the government policies also promoted the development of the ISA. Meanwhile, topographical features like the National Nature Reserve of China restricted and affected the expansion of the ISA. Above all, this paper attempted to extract ISA in a major region of the PRD; the temporal and spatial analyses to PRD ISA demonstrated the drastic changes in developed areas of China. These results were important and valuable for land use management, ecological protection and policy establishment. PMID:22438741

  20. Extraction and analysis of impervious surfaces based on a spectral un-mixing method using Pearl River Delta of China Landsat TM/ETM+ imagery from 1998 to 2008.

    PubMed

    Deng, Yingbin; Fan, Fenglei; Chen, Renrong

    2012-01-01

    Impervious surface area (ISA) is considered as an indicator of environment change and is regarded as an important input parameter for hydrological cycle simulation, water management and area pollution assessment. The Pearl River Delta (PRD), the 3rd most important economic district of China, is chosen in this paper to extract the ISA information based on Landsat images of 1998, 2003 and 2008 by using a linear spectral un-mixing method and to monitor impervious surface change by analyzing the multi-temporal Landsat-derived fractional impervious surface. Results of this study were as follows: (1) the area of ISA in the PRD increased 79.09% from 1998 to 2003 and 26.88% from 2003 to 2008 separately; (2) the spatial distribution of ISA was described according to the 1998/2003 percentage respectively. Most of middle and high percentage ISA was located in northwestern and southeastern of the whole delta, and middle percentage ISA was mainly located in the city interior, high percentage ISA was mainly located in the suburban around the city accordingly; (3) the expanding direction and trend of high percentage ISA was discussed in order to understand the change of urban in this delta; High percentage ISA moved from inner city to edge of urban area during 1998-2003 and moved to the suburban area that far from the urban area mixed with jumpily and gradually during 2003-2008. According to the discussion of high percentage ISA spatial expanded direction, it could be found out that high percentage ISA moved outward from the centre line of Pearl River of the whole delta while a high ISA percentage in both shores of the Pearl River Estuary moved toward the Pearl River; (4) combining the change of ISA with social conditions, the driving relationship was analyzed in detail. It was evident that ISA percentage change had a deep relationship with the economic development of this region in the past ten years. Contemporaneous major sport events (16th Asia Games of Guangzhou, 26th Summer Universidad of Shenzhen) and the government policies also promoted the development of the ISA. Meanwhile, topographical features like the National Nature Reserve of China restricted and affected the expansion of the ISA. Above all, this paper attempted to extract ISA in a major region of the PRD; the temporal and spatial analyses to PRD ISA demonstrated the drastic changes in developed areas of China. These results were important and valuable for land use management, ecological protection and policy establishment.

  1. Silicon bulk micromachined, symmetric, degenerate vibratorygyroscope, accelerometer and sensor and method for using the same

    NASA Technical Reports Server (NTRS)

    Tang, Tony K. (Inventor); Kaiser, William J. (Inventor); Bartman, Randall K. (Inventor); Wilcox, Jaroslava Z. (Inventor); Gutierrez, Roman C. (Inventor); Calvet, Robert J. (Inventor)

    1999-01-01

    When embodied in a microgyroscope, the invention is comprised of a silicon, four-leaf clover structure with a post attached to the center. The whole structure is suspended by four silicon cantilevers or springs. The device is electrostatically actuated and capacitively detects Coriolis induced motions of the leaves of the leaf clover structure. In the case where the post is not symmetric with the plane of the clover leaves, the device can is usable as an accelerometer. If the post is provided in the shape of a dumb bell or an asymmetric post, the center of gravity is moved out of the plane of clover leaf structure and a hybrid device is provided. When the clover leaf structure is used without a center mass, it performs as a high Q resonator usable as a sensor of any physical phenomena which can be coupled to the resonant performance.

  2. Preamble to the Integrated Science Assessments (ISA)

    EPA Science Inventory

    The Preamble to the Integrated Science Assessments, or "Preamble", is an overview document outlining the basic steps and criteria used in developing the Integrated Science Assessments (ISA). Previously included as part of the ISA, it will now be referenced by each ISA as...

  3. ISA implementation and uncertainty: a literature review and expert elicitation study.

    PubMed

    van der Pas, J W G M; Marchau, V A W J; Walker, W E; van Wee, G P; Vlassenroot, S H

    2012-09-01

    Each day, an average of over 116 people die from traffic accidents in the European Union. One out of three fatalities is estimated to be the result of speeding. The current state of technology makes it possible to make speeding more difficult, or even impossible, by placing intelligent speed limiters (so called ISA devices) in vehicles. Although the ISA technology has been available for some years now, and reducing the number of road traffic fatalities and injuries has been high on the European political agenda, implementation still seems to be far away. Experts indicate that there are still too many uncertainties surrounding ISA implementation, and dealing with these uncertainties is essential for implementing ISA. In this paper, a systematic and representative inventory of the uncertainties is made based upon the literature. Furthermore, experts in the field of ISA were surveyed and asked which uncertainties are barriers for ISA implementation, and how uncertain these uncertainties are. We found that the long-term effects and the effects of large-scale implementation of ISA are still uncertain and are the most important barriers for the implementation of the most effective types of ISA. One way to deal with these uncertainties would be to start implementation on a small scale and gradually expand the penetration, in order to learn how ISA influences the transport system over time. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Global Distribution and Density of Constructed Impervious Surfaces.

    PubMed

    Elvidge, Christopher D; Tuttle, Benjamin T; Sutton, Paul C; Baugh, Kimberly E; Howard, Ara T; Milesi, Cristina; Bhaduri, Budhendra; Nemani, Ramakrishna

    2007-09-21

    We present the first global inventory of the spatial distribution and density ofconstructed impervious surface area (ISA). Examples of ISA include roads, parking lots,buildings, driveways, sidewalks and other manmade surfaces. While high spatialresolution is required to observe these features, the new product reports the estimateddensity of ISA on a one-km² grid based on two coarse resolution indicators of ISA - thebrightness of satellite observed nighttime lights and population count. The model wascalibrated using 30-meter resolution ISA of the USA from the U.S. Geological Survey.Nominally the product is for the years 2000-01 since both the nighttime lights andreference data are from those two years. We found that 1.05% of the United States landarea is impervious surface (83,337 km²) and 0.43 % of the world's land surface (579,703km²) is constructed impervious surface. China has more ISA than any other country(87,182 km²), but has only 67 m² of ISA per person, compared to 297 m² per person in theUSA. The distribution of ISA in the world's primary drainage basins indicates that watersheds damaged by ISA are primarily concentrated in the USA, Europe, Japan, China and India. The authors believe the next step for improving the product is to include reference ISA data from many more areas around the world.

  5. Comparative study on the immunopotentiator effect of ISA 201, ISA 61, ISA 50, ISA 206 used in trivalent foot and mouth disease vaccine

    PubMed Central

    Ibrahim, Ehab El-Sayed; Gamal, Wael Mossad; Hassan, Amr Ismail; Mahdy, Safy El-Din; Hegazy, Akram Zakria; Abdel-Atty, Magdy Mahmoud

    2015-01-01

    Aim: A comparison study was conducted to explore the best internationally available adjuvant that could be used in production of a highly potent foot and mouth disease (FMD) vaccine, that could stimulate a strong immune response and possibly give greater protection against FMD. Materials and Methods: Four experimental batches of trivalent FMD vaccine were prepared with different available oil adjuvants which included Montanide ISA 201, 206, 61 and 50. Results: The results indicated that vaccines emulsified using Montanide ISA 201 and Montanide ISA 206 adjuvants elicited a protective humoral immune response from the 2nd week postvaccination (WPV) as for ISA 201 with serum neutralization test (SNT) and enzyme-linked immune sorbent assay (ELISA) antibody titers of 1.62±0.047a and 1.8±0.049a, 1.59±0.076a and 1.836±0.077a, and 1.71±0.06b and 1.96±0.074b for serotypes O, A, SAT2, respectively, and for ISA 206 at SNT and ELISA antibody titers of 1.5±0.082a and 1.84±0.084a, 1.56±0.037a and 1.818±0.052a, and 1.5±0.106a,b and 1.81±0.104a,b for FMD virus serotypes O, A and SAT2, respectively. For ISA 61 and ISA 50, the protective antibody titer appeared in the 3rd WPV. In the ISA 61 FMD vaccine, SNT and ELISA titer were 1.59±0.076a and 1.9±0.094a, 1.53±0.056a and 1.83±0.070a, and 1.5±0.082a and 1.84±0.094a for serotypes O, A and SAT2, respectively, and in the case of ISA 50 FMD vaccine, the SNT, and ELISA titer were recorded for serotypes O, A and SAT2 respectively, 1.59±0.037a and 1.8±0.030a, 1.68±0.056a,b and 1.916±0.065a,b, and 1.65±0.082a and 1.9±0.09a. On estimating the cellular immune response, the highest delta optical density levels for ISA 201 (0.395-0.460) and ISA 206 (0.375-0.428) were observed on 14 and 21 days post vaccination (DPV) respectively, while the highest levels of lymphoproliferation for ISA 61 (0.375-0.455) and ISA 50 (0.411-0.430) were on 21 and 28 DPV, respectively. Conclusion: The duration of immunity from Montanide ISA oils (201, 206, 61 and 50) FMD vaccines is a long-lived immunity which ranged between 32 and 38 weeks post vaccination but the Montanide ISA 201 FMD vaccine is superior to the others in the rapid cellular immune response of the vaccinated animals which showed its highest level within 14 days post vaccination. PMID:27047016

  6. Sensing power transfer between the human body and the environment.

    PubMed

    Veltink, Peter H; Kortier, Henk; Schepers, H Martin

    2009-06-01

    The power transferred between the human body and the environment at any time and the work performed are important quantities to be estimated when evaluating and optimizing the physical interaction between the human body and the environment in sports, physical labor, and rehabilitation. It is the objective of the current paper to present a concept for estimating power transfer between the human body and the environment during free motions and using sensors at the interface, not requiring measurement systems in the environment, and to experimentally demonstrate this principle. Mass and spring loads were moved by hand over a fixed height difference via varying free movement trajectories. Kinematic and kinetic quantities were measured in the handle between the hand and the load. 3-D force and moments were measured using a 6 DOF force/moment sensor module, 3-D movement was measured using 3-D accelerometers and angular velocity sensors. The orientation was estimated from the angular velocity, using the initial orientation as a begin condition. The accelerometer signals were expressed in global coordinates using this orientation information. Velocity was estimated by integrating acceleration in global coordinates, obtained by adding gravitational acceleration to the accelerometer signals. Zero start and end velocities were used as begin and end conditions. Power was calculated as the sum of the inner products of velocity and force and of angular velocity and moment, and work was estimated by integrating power over time. The estimated performed work was compared to the potential energy difference corresponding to the change in height of the loads and appeared to be accurate within 4% for varying movements with net displacements and varying loads (mass and spring). The principle of estimating power transfer demonstrated in this paper can be used in future interfaces between the human body and the environment instrumented with body-mounted miniature 3-D force and acceleration sensors.

  7. Evaluation of a six-DOF electrodynamic shaker system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gregory, Danny Lynn; Smallwood, David Ora

    2009-03-01

    The paper describes the preliminary evaluation of a 6 degree of freedom electrodynamic shaker system. The 8 by 8 inch (20.3 cm) table is driven by 12 electrodynamic shakers producing motion in all 6 rigid body modes. A small electrodynamic shaker system suitable for small component testing is described. The principal purpose of the system is to demonstrate the technology. The shaker is driven by 12 electrodynamic shakers each with a force capability of about 50 lbs (220 N). The system was developed through an informal cooperative agreement between Sandia National Laboratories, Team Corp. and Spectral Dynamics Corporation. Sandia providedmore » the laboratory space and some development funds. Team provided the mechanical system, and Spectral Dynamics provided the control system. Spectral Dynamics was chosen to provide the control system partly because of their experience in MIMO control and partly because Sandia already had part of the system in house. The shaker system was conceived and manufactured by TEAM Corp. Figure 1 shows the overall system. The vibration table, electrodynamic shakers, hydraulic pumps, and amplifiers are all housed in a single cabinet. Figure 2 is a drawing showing how the electrodynamic shakers are coupled to the table. The shakers are coupled to the table through a hydraulic spherical pad bearing providing 5 degrees of freedom and one stiff degree of freedom. The pad bearing must be preloaded with a static force as they are unable to provide any tension forces. The horizontal bearings are preloaded with steel springs. The drawing shows a spring providing the vertical preload. This was changed in the final design. The vertical preload is provided by multiple strands of an O-ring material as shown in Figure 4. Four shakers provide excitation in each of the three orthogonal axes. The specifications of the shaker are outlined in Table 1. Four shakers provide inputs in each of the three orthogonal directions. By choosing the phase relationships between the shakers all six rigid body modes (three translation, and three rotations) can be excited. The system is over determined. There are more shakers than degrees of freedom. This provided an interesting control problem. The problem was approached using the input-output transformation matrices provided in the Spectral control system. Twelve accelerometers were selected for the control accelerometers (a tri-axial accelerometer at each corner of the table (see Figure 5). Figure 6 shows the nomenclature used to identify the shakers and control accelerometers. A fifth tri-axial accelerometer was placed at the center of the table, but it was not used for control. Thus we had 12 control accelerometers and 12 shakers to control a 6-dof shaker. The 12 control channels were reduced to a 6-dof control using a simple input transformation matrix. The control was defined by a 6x6 spectral density matrix. The six outputs in the control variable coordinates were transformed to twelve physical drive signals using another simple output transformation matrix. It was assumed that the accelerometers and shakers were well matched such that the transformation matrices were independent of frequency and could be deduced from rigid body considerations. The input/output transformations are shown in Equations 1 and 2.« less

  8. What benefit does Intelligent Speed Adaptation deliver: a close examination of its effect on vehicle speeds.

    PubMed

    Lai, Frank; Carsten, Oliver

    2012-09-01

    Intelligent Speed Adaptation (ISA) is a driver support system which brings the speed limit information into the vehicle. This paper describes the UK ISA field trials taken place between 2004 and 2006 and presents evidence on how drivers' choice of speed is altered. The ISA system was observed to have a distinctive effect in transforming the speed distribution from a conventional bell shape to an asymmetric distribution biased towards the high speed end. ISA not only diminished excessive speeding, but also led to a reduction in speed variation, prompting a positive implication to accident reduction. The use of an overridable ISA system also provided an opportunity to investigate where drivers would choose to have ISA based on observed behaviour instead of opinion. Evidence shows that ISA tends to be overridden on roads where it was perhaps needed most. Behavioural difference among driver groups also suggests that ISA tends to be overridden by those drivers who in safety terms stand to benefit most from using it, as with other safety systems. Copyright © 2010 Elsevier Ltd. All rights reserved.

  9. Can enforced behaviour change attitudes: exploring the influence of Intelligent Speed Adaptation.

    PubMed

    Chorlton, Kathryn; Conner, Mark

    2012-09-01

    The Theory of Planned Behaviour model (Ajzen, 1985) was used to determine whether long-term experience with Intelligent Speed Adaption (ISA) prompts a change in speed related cognitions. The study examines data collected as part of a project examining driver behaviour with an intervening but overridable ISA system. Data was collected in four six-month field trials. The trials followed an A-B-A design (28 days driving with no ISA, 112 days driving with ISA, 28 days driving without ISA) to monitor changes in speeding behaviour as a result of the ISA system and any carry-over effect of the system. Findings suggested that following experience with the system, drivers' intention to speed significantly weakened, beyond the removal of ISA support. Drivers were also less likely to believe that exceeding the speed would 'get them to their destination more quickly' and less likely to believe that 'being in a hurry' would facilitate speeding. However, the positive change in intentions and beliefs failed to translate into behaviour. Experience with the ISA system significantly reduced the percentage of distance travelled whilst exceeding the speed limit but this effect was not evident when the ISA support was removed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. How much benefit does Intelligent Speed Adaptation deliver: an analysis of its potential contribution to safety and environment.

    PubMed

    Lai, Frank; Carsten, Oliver; Tate, Fergus

    2012-09-01

    The UK Intelligent Speed Adaptation (ISA) project produced a rich database with high-resolution data on driver behaviour covering a comprehensive range of road environment. The field trials provided vital information on driver behaviour in the presence of ISA. The purpose of this paper is to exploit the information gathered in the field trials to predict the impacts of various forms of ISA and to assess whether ISA is viable in terms of benefit-to-cost ratio. ISA is predicted to save up to 33% of accidents on urban roads, and to reduce CO(2) emissions by up to 5.8% on 70 mph roads. In order to investigate the long-term impacts of ISA, two hypothetical deployment scenarios were envisaged covering a 60-year appraisal period. The results indicate that ISA could deliver a very healthy benefit-to-cost ratio, ranging from 3.4 to 7.4, depending on the deployment scenarios. Under both deployment scenarios, ISA has recovered its implementation costs in less than 15 years. It can be concluded that implementation of ISA is clearly justified from a social cost and benefit perspective. Of the two deployment scenarios, the Market Driven one is substantially outperformed by the Authority Driven one. The benefits of ISA on fuel saving and emission reduction are real but not substantial, in comparison with the benefits on accident reduction; up to 98% of benefits are attributable to accident savings. Indeed, ISA is predicted to lead to a savings of 30% in fatal crashes and 25% in serious crashes over the 60-year period modelled. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Intelligent speed adaptation as an assistive device for drivers with acquired brain injury: a single-case field experiment.

    PubMed

    Klarborg, Brith; Lahrmann, Harry; NielsAgerholm; Tradisauskas, Nerius; Harms, Lisbeth

    2012-09-01

    Intelligent speed adaptation (ISA) was tested as an assistive device for drivers with an acquired brain injury (ABI). The study was part of the "Pay as You Speed" project (PAYS) and used the same equipment and technology as the main study (Lahrmann et al., in press-a, in press-b). Two drivers with ABI were recruited as subjects and had ISA equipment installed in their private vehicle. Their speed was logged with ISA equipment for a total of 30 weeks of which 12 weeks were with an active ISA user interface (6 weeks=Baseline 1; 12 weeks=ISA period; 12 weeks=Baseline 2). The subjects participated in two semi-structured interviews concerning their strategies for driving with ABI and for driving with ISA. Furthermore, they gave consent to have data from their clinical journals and be a part of the study. The two subjects did not report any instances of being distracted or confused by ISA, and in general they described driving with ISA as relaxed. ISA reduced the percentage of the total distance that was driven with a speed above the speed limit (PDA), but the subjects relapsed to their previous PDA level in Baseline 2. This suggests that ISA is more suited as a permanent assistive device (i.e. cognitive prosthesis) than as a temporary training device. As ABI is associated with a multitude of cognitive deficits, we developed a conceptual framework, which focused on the cognitive parameters that have been shown to relate to speeding behaviour, namely "intention to speed" and "inattention to speeding". The subjects' combined status on the two independent parameters made up their "speeding profile". A comparison of the speeding profiles and the speed logs indicated that ISA in the present study was more efficient in reducing inattention to speeding than affecting intention to speed. This finding suggests that ISA might be more suited for some neuropsychological profiles than for others, and that customisation of ISA for different neuropsychological profiles may be required. However, further studies with more subjects are needed in order to be conclusive on these issues. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Superconducting gravity gradiometer and a test of inverse square law

    NASA Technical Reports Server (NTRS)

    Moody, M. V.; Paik, Ho Jung

    1989-01-01

    The equivalence principle prohibits the distinction of gravity from acceleration by a local measurement. However, by making a differential measurement of acceleration over a baseline, platform accelerations can be cancelled and gravity gradients detected. In an in-line superconducting gravity gradiometer, this differencing is accomplished with two spring-mass accelerometers in which the proof masses are confined to motion in a single degree of freedom and are coupled together by superconducting circuits. Platform motions appear as common mode accelerations and are cancelled by adjusting the ratio of two persistent currents in the sensing circuit. The sensing circuit is connected to a commercial SQUID amplifier to sense changes in the persistent currents generated by differential accelerations, i.e., gravity gradients. A three-axis gravity gradiometer is formed by mounting six accelerometers on the faces of a precision cube, with the accelerometers on opposite faces of the cube forming one of three in-line gradiometers. A dedicated satellite mission for mapping the earth's gravity field is an important one. Additional scientific goals are a test of the inverse square law to a part in 10(exp 10) at 100 km, and a test of the Lense-Thirring effect by detecting the relativistic gravity magnetic terms in the gravity gradient tensor for the earth.

  13. 78 FR 22895 - Test To Allow Customs Brokers To Pre-Certify Importers for Participation in the Importer Self...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-17

    ... pre-certify importers for participation in the Importer Self-Assessment (ISA) program. The test will be known as the Customs Broker Importer Self-Assessment Pre- Certification (Broker ISA PC) test. The... Importer Self-Assessment (ISA) program. The Broker Importer Self-Assessment Pre-Certification (ISA PC) test...

  14. Interior search algorithm (ISA): a novel approach for global optimization.

    PubMed

    Gandomi, Amir H

    2014-07-01

    This paper presents the interior search algorithm (ISA) as a novel method for solving optimization tasks. The proposed ISA is inspired by interior design and decoration. The algorithm is different from other metaheuristic algorithms and provides new insight for global optimization. The proposed method is verified using some benchmark mathematical and engineering problems commonly used in the area of optimization. ISA results are further compared with well-known optimization algorithms. The results show that the ISA is efficiently capable of solving optimization problems. The proposed algorithm can outperform the other well-known algorithms. Further, the proposed algorithm is very simple and it only has one parameter to tune. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Strong Seasonality of Marine Microbial Eukaryotes in a High-Arctic Fjord (Isfjorden, in West Spitsbergen, Norway)

    PubMed Central

    Vader, Anna; Stübner, Eike I.; Reigstad, Marit

    2016-01-01

    The Adventfjorden time series station (IsA) in Isfjorden, West Spitsbergen, Norway, was sampled frequently from December 2011 to December 2012. The community composition of microbial eukaryotes (size, 0.45 to 10 μm) from a depth of 25 m was determined using 454 sequencing of the 18S V4 region amplified from both DNA and RNA. The compositional changes throughout the year were assessed in relation to in situ fjord environmental conditions. Size fractionation analyses of chlorophyll a showed that the photosynthetic biomass was dominated by small cells (<10 μm) most of the year but that larger cells dominated during the spring and summer. The winter and early-spring communities were more diverse than the spring and summer/autumn communities. Dinophyceae were predominant throughout the year. The Arctic Micromonas ecotype was abundant mostly in the early-bloom and fall periods, whereas heterotrophs, such as marine stramenopiles (MASTs), Picozoa, and the parasitoid marine alveolates (MALVs), displayed higher relative abundance in the winter than in other seasons. Our results emphasize the extreme seasonality of Arctic microbial eukaryotic communities driven by the light regime and nutrient availability but point to the necessity of a thorough knowledge of hydrography for full understanding of their succession and variability. PMID:26746718

  16. Using long time series of Landsat data to monitor impervious surface dynamics: a case study in the Zhoushan Islands

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoping; Pan, Delu; Chen, Jianyu; Zhan, Yuanzeng; Mao, Zhihua

    2013-01-01

    Islands are an important part of the marine ecosystem. Increasing impervious surfaces in the Zhoushan Islands due to new development and increased population have an ecological impact on the runoff and water quality. Based on time-series classification and the complement of vegetation fraction in urban regions, Landsat thematic mapper and other high-resolution satellite images were applied to monitor the dynamics of impervious surface area (ISA) in the Zhoushan Islands from 1986 to 2011. Landsat-derived ISA results were validated by the high-resolution Worldview-2 and aerial photographs. The validation shows that mean relative errors of these ISA maps are <15 %. The results reveal that the ISA in the Zhoushan Islands increased from 19.2 km2 in 1986 to 86.5 km2 in 2011, and the period from 2006 to 2011 had the fastest expansion rate of 5.59 km2 per year. The major land conversions to high densities of ISA were from the tidal zone and arable lands. The expansions of ISA were unevenly distributed and most of them were located along the periphery of these islands. Time-series maps revealed that ISA expansions happened continuously over the last 25 years. Our analysis indicated that the policy and the topography were the dominant factors controlling the spatial patterns of ISA and its expansions in the Zhoushan Islands. With continuous urbanization processes, the rapid ISA expansions may not be stopped in the near feature.

  17. The Simultaneous Abolition of Three Starch Hydrolases Blocks Transient Starch Breakdown in Arabidopsis*

    PubMed Central

    Streb, Sebastian; Eicke, Simona; Zeeman, Samuel C.

    2012-01-01

    In this study, we investigated which enzymes are involved in debranching amylopectin during transient starch degradation. Previous studies identified two debranching enzymes, isoamylase 3 (ISA3) and limit dextrinase (LDA), involved in this process. However, plants lacking both enzymes still degrade substantial amounts of starch. Thus, other enzymes/mechanisms must contribute to starch breakdown. We show that the chloroplastic α-amylase 3 (AMY3) also participates in starch degradation and provide evidence that all three enzymes can act directly at the starch granule surface. The isa3 mutant has a starch excess phenotype, reflecting impaired starch breakdown. In contrast, removal of AMY3, LDA, or both enzymes together has no impact on starch degradation. However, removal of AMY3 or LDA in addition to ISA3 enhances the starch excess phenotype. In plants lacking all three enzymes, starch breakdown is effectively blocked, and starch accumulates to the highest levels observed so far. This provides indirect evidence that the heteromultimeric debranching enzyme ISA1-ISA2 is not involved in starch breakdown. However, we illustrate that ISA1-ISA2 can hydrolyze small soluble branched glucans that accumulate when ISA3 and LDA are missing, albeit at a slow rate. Starch accumulation in the mutants correlates inversely with plant growth. PMID:23019330

  18. Fosaprepitant-induced phlebitis: a focus on patients receiving doxorubicin/cyclophosphamide therapy.

    PubMed

    Leal, A D; Kadakia, K C; Looker, S; Hilger, C; Sorgatz, K; Anderson, K; Jacobson, A; Grendahl, D; Seisler, D; Hobday, T; Loprinzi, Charles L

    2014-05-01

    The purpose of this study was to investigate the incidence of fosaprepitant-associated infusion site adverse events (ISAEs) among a cohort of breast cancer patients receiving doxorubicin/cyclophosphamide (AC) chemotherapy. A retrospective review of electronic medical record (EMR) data was performed for all patients who were initiated on AC from January 2011 to April 2012. Data collected included baseline demographics, antiemetic regimen, documentation of ISAEs, and type of intravenous (IV) access. Descriptive statistics (mean and standard deviation or percentages) were summarized overall, by type of IV access and initial antiemetic given. Among the 148 patients included in this analysis, 98 initially received fosaprepitant and 44 received aprepitant. The incidence of ISAEs associated with fosaprepitant administration was 34.7 % (n=34), while the incidence of aprepitant-associated ISAEs was 2.3 % (n=1). All ISAEs were associated with peripheral IV access. The most commonly reported ISAEs were infusion site pain (n=26), erythema (n=22), swelling (n=12), superficial thrombosis (n=8), infusion site hives (n=5), and phlebitis/thrombophlebitis (n=5). Twenty-six patients experienced more than one type of ISAE. The incidence and severity of ISAEs associated with fosaprepitant administration among a group of patients receiving AC chemotherapy are significant and appreciably higher than what has been previously reported.

  19. Fosaprepitant-induced Phlebitis: A Focus on Patients receiving Doxorubicin/Cyclophosphamide therapy

    PubMed Central

    Leal, A. D.; Kadakia, K. C.; Looker, S.; Hilger, C.; Sorgatz, K.; Anderson, K.; Jacobson, A.; Grendahl, D.; Seisler, D.; Hobday, T.; Loprinzi, C. L.

    2014-01-01

    Purpose The purpose of this study was to investigate the incidence of fosaprepitant-associated infusion site adverse events (ISAEs) among a cohort of breast cancer patients receiving doxorubicin/cyclophosphamide (AC) chemotherapy. Methods A retrospective review of electronic medical record (EMR) data was performed for all patients who were initiated on AC from January 2011 to April 2012. Data collected included baseline demographics, antiemetic regimen, documentation of ISAEs and type of intravenous (IV) access. Descriptive statistics (mean and standard deviation or percentages) were summarized overall, by type of IV access and initial antiemetic given. Results Among the 148 patients included in this analysis, 98 initially received fosaprepitant and 44 received aprepitant. The incidence of ISAEs associated with fosaprepitant administration was 34.7% (n=34), while the incidence of aprepitant-associated ISAEs was 2.3% (n=1). All ISAEs were associated with peripheral IV access. The most commonly reported ISAEs were: infusion site pain (n=26), erythema (n=22), swelling (n=12), superficial thrombosis (n=8), infusion site hives (n=5) and phlebitis/thrombophlebitis (n=5). Twenty-six patients experienced more than one type of ISAE. Conclusions The incidence and severity of ISAEs associated with fosaprepitant administration among a group of patients receiving AC chemotherapy is significant and appreciably higher than what has been previously reported. PMID:24402411

  20. The biogeochemical fate of nickel during microbial ISA degradation; implications for nuclear waste disposal.

    PubMed

    Kuippers, Gina; Boothman, Christopher; Bagshaw, Heath; Ward, Michael; Beard, Rebecca; Bryan, Nicholas; Lloyd, Jonathan R

    2018-06-08

    Intermediate level radioactive waste (ILW) generally contains a heterogeneous range of organic and inorganic materials, of which some are encapsulated in cement. Of particular concern are cellulosic waste items, which will chemically degrade under the conditions predicted during waste disposal, forming significant quantities of isosaccharinic acid (ISA), a strongly chelating ligand. ISA therefore has the potential to increase the mobility of a wide range of radionuclides via complex formation, including Ni-63 and Ni-59. Although ISA is known to be metabolized by anaerobic microorganisms, the biodegradation of metal-ISA complexes remains unexplored. This study investigates the fate of a Ni-ISA complex in Fe(III)-reducing enrichment cultures at neutral pH, representative of a microbial community in the subsurface. After initial sorption of Ni onto Fe(III)oxyhydroxides, microbial ISA biodegradation resulted in >90% removal of the remaining Ni from solution when present at 0.1 mM, whereas higher concentrations of Ni proved toxic. The microbial consortium associated with ISA degradation was dominated by close relatives to Clostridia and Geobacter species. Nickel was preferentially immobilized with trace amounts of biogenic amorphous iron sulfides. This study highlights the potential for microbial activity to help remove chelating agents and radionuclides from the groundwater in the subsurface geosphere surrounding a geodisposal facility.

  1. Acclimation of Oxygenic Photosynthesis to Iron Starvation Is Controlled by the sRNA IsaR1.

    PubMed

    Georg, Jens; Kostova, Gergana; Vuorijoki, Linda; Schön, Verena; Kadowaki, Taro; Huokko, Tuomas; Baumgartner, Desirée; Müller, Maximilian; Klähn, Stephan; Allahverdiyeva, Yagut; Hihara, Yukako; Futschik, Matthias E; Aro, Eva-Mari; Hess, Wolfgang R

    2017-05-22

    Oxygenic photosynthesis crucially depends on proteins that possess Fe 2+ or Fe/S complexes as co-factors or prosthetic groups. Here, we show that the small regulatory RNA (sRNA) IsaR1 (Iron-Stress-Activated RNA 1) plays a pivotal role in acclimation to low-iron conditions. The IsaR1 regulon consists of more than 15 direct targets, including Fe 2+ -containing proteins involved in photosynthetic electron transfer, detoxification of anion radicals, citrate cycle, and tetrapyrrole biogenesis. IsaR1 is essential for maintaining physiological levels of Fe/S cluster biogenesis proteins during iron deprivation. Consequently, IsaR1 affects the acclimation of the photosynthetic apparatus to iron starvation at three levels: (1) directly, via posttranscriptional repression of gene expression; (2) indirectly, via suppression of pigment; and (3) Fe/S cluster biosynthesis. Homologs of IsaR1 are widely conserved throughout the cyanobacterial phylum. We conclude that IsaR1 is a critically important riboregulator. These findings provide a new perspective for understanding the regulation of iron homeostasis in photosynthetic organisms. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Classical Mechanics Experiments using Wiimotes

    NASA Astrophysics Data System (ADS)

    Lopez, Alexander; Ochoa, Romulo

    2010-02-01

    The Wii, a video game console, is a very popular device. Although computationally it is not a powerful machine by today's standards, to a physics educator the controllers are its most important components. The Wiimote (or remote) controller contains a three-axis accelerometer, an infrared detector, and Bluetooth connectivity at a relatively low price. Thanks to available open source code, such as GlovePie, any PC or Laptop with Bluetooth capability can detect the information sent out by the Wiimote. We present experiments that use two or three Wiimotes simultaneously to measure the variable accelerations in two mass systems interacting via springs. Normal modes are determined from the data obtained. Masses and spring constants are varied to analyze their impact on the accelerations of the systems. We present the results of our experiments and compare them with those predicted using Lagrangian mechanics. )

  3. Equating accelerometer estimates among youth: the Rosetta Stone 2

    PubMed Central

    Brazendale, Keith; Beets, Michael W.; Bornstein, Daniel B.; Moore, Justin B.; Pate, Russell R.; Weaver, Robert G.; Falck, Ryan S.; Chandler, Jessica L.; Andersen, Lars B.; Anderssen, Sigmund A.; Cardon, Greet; Cooper, Ashley; Davey, Rachel; Froberg, Karsten; Hallal, Pedro C.; Janz, Kathleen F.; Kordas, Katarzyna; Kriemler, Susi; Puder, Jardena J.; Reilly, John J.; Salmon, Jo; Sardinha, Luis B.; Timperio, Anna; van Sluijs, Esther MF

    2017-01-01

    Objectives Different accelerometer cutpoints used by different researchers often yields vastly different estimates of moderate-to-vigorous intensity physical activity (MVPA). This is recognized as cutpoint non-equivalence (CNE), which reduces the ability to accurately compare youth MVPA across studies. The objective of this research is to develop a cutpoint conversion system that standardizes minutes of MVPA for six different sets of published cutpoints. Design Secondary data analysis Methods Data from the International Children’s Accelerometer Database (ICAD; Spring 2014) consisting of 43,112 Actigraph accelerometer data files from 21 worldwide studies (children 3-18 years, 61.5% female) were used to develop prediction equations for six sets of published cutpoints. Linear and non-linear modeling, using a leave one out cross-validation technique, was employed to develop equations to convert MVPA from one set of cutpoints into another. Bland Altman plots illustrate the agreement between actual MVPA and predicted MVPA values. Results Across the total sample, mean MVPA ranged from 29.7 MVPA min.d-1 (Puyau) to 126.1 MVPA min.d-1 (Freedson 3 METs). Across conversion equations, median absolute percent error was 12.6% (range: 1.3 to 30.1) and the proportion of variance explained ranged from 66.7% to 99.8%. Mean difference for the best performing prediction equation (VC from EV) was -0.110 min.d-1 (limits of agreement (LOA), -2.623 to 2.402). The mean difference for the worst performing prediction equation (FR3 from PY) was 34.76 min.d-1 (LOA, -60.392 to 129.910). Conclusions For six different sets of published cutpoints, the use of this equating system can assist individuals attempting to synthesize the growing body of literature on Actigraph, accelerometry-derived MVPA. PMID:25747468

  4. Too hot to move? Objectively assessed seasonal changes in Australian children's physical activity.

    PubMed

    Ridgers, Nicola D; Salmon, Jo; Timperio, Anna

    2015-06-19

    Seasonal variations may influence children's physical activity patterns. The aim of this study was to examine how children's objectively-measured physical activity differed across seasons, and whether different seasonal patterns were observed for boys and girls. Three hundred and twenty-six children aged 8-11 years from nine primary schools in Melbourne, Australia, participated in the study. Physical activity was measured every 15-s using hip-mounted GT3X+ ActiGraph accelerometers for seven consecutive days in the Winter (n = 249), Spring (n = 221), Summer (n = 174) and Autumn (n = 152) school terms. Time spent in moderate (MPA), vigorous (VPA) and moderate- to vigorous-intensity physical activity (MVPA) at each time point was derived using age-specific cut-points. Meteorological data (maximum temperature, precipitation, daylight hours) were obtained daily during each season. Longitudinal data were analysed using multilevel analyses, adjusted for age, sex, accelerometer wear time, number of valid days, and meteorological variables. Compared to Winter, children engaged in significantly less MPA (-5.0 min) and MVPA (-7.8 min) in Summer. Girls engaged in less MVPA in Spring (-18 min) and Summer (-9.2 min) and more MVPA in Autumn (9.9 min) compared to Winter. Significant changes in MPA and VPA bout frequency and duration were also observed. Significant decreases in VPA bout frequency (3.4 bouts) and duration (2.6 min) were observed for girls in Spring compared to Winter. No significant seasonal changes were observed for boys for all intensities and physical activity accumulation. Physical activity decreased in Summer compared to Winter, contrasting previous research that typically reports that children are most active in summer. Greater fluctuations were observed for girls' activity levels. In addition, girls' activity duration and bouts appeared to be more susceptible to seasonal changes compared to boys. The results suggest that strategies to promote physical activity may be needed in Australia during the hot summer months, particularly for girls.

  5. Could Intelligent Speed Adaptation make overtaking unsafe?

    PubMed

    Jamson, Samantha; Chorlton, Kathryn; Carsten, Oliver

    2012-09-01

    This driving simulator study investigated how mandatory and voluntary ISA might affect a driver's overtaking decisions on rural roads, by presenting drivers with a variety of overtaking scenarios designed to evaluate both the frequency and safety of the manoeuvres. In half the overtaking scenarios, ISA was active and in the remainder ISA was switched off. A rural road was modelled with a number of 2+1 road sections, thus allowing drivers a protected overtaking opportunity. The results indicate that drivers became less inclined to initiate an overtaking manoeuvre when the mandatory ISA was active and this was particularly so when the overtaking opportunity was short. In addition to this, when ISA was activated drivers were more likely to have to abandon an overtaking, presumably due to running out of road. They also spent more time in the critical hatched area-a potentially unsafe behaviour. The quality of the overtaking manoeuvre was also affected when mandatory ISA was active, with drivers pulling out and cutting back in more sharply. In contrast, when driving with a voluntary ISA, overtaking behaviour remained mostly unchanged: drivers disengaged the function in approximately 70% of overtaking scenarios. The results of this study suggest that mandatory ISA could affect the safety of overtaking manoeuvres unless coupled with an adaptation period or other driver support functions that support safe overtaking. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Standardizng Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, Nathan A.; Klemm, Juli; Harper, Stacey

    2013-02-05

    To enable the rational design of nanomaterials for improved efficacy and safety, it is critical to understand and exploit the physicochemical properties that drive biological behavior (Morris, 2010). Data mining and computer simulation are essential for deriving information about nanomaterial behavior; however, the datasets needed to support such studies are sparse and stored across a variety of repositories and resources. Schrurs and Lison (2012) have expressed the need for more coherence and structure in the conduct of nanotechnology research. Additionally, the lack of common reporting standards and non-uniformity of information reported have proven to be significant barriers to such datamore » sharing and re-use. The Nanotechnology Working Group (Nano WG), of the US National Institutes of Health National Cancer Informatics Program, has been focused on addressing these barriers. The Nano WG - which includes representatives from over 20 organizations including government agencies, academia, industry, standards organizations, and alliances -has developed ISA-TAB-Nano (Thomas et al, 2013), a general framework for representing and integrating diverse types of data related to the description and characterization of nanomaterials. Recognizing that nanoparticle characterization studies have many of the same challenges as ‘omics-based assays, the Nano WG joined the ISA Commons (Sansone et al., 2012) to leverage lessons learned in ‘omics data sharing. The ISA Commons community brings together 50 collaborators at over 30 scientific organizations around the globe, including regulatory and industrial participants in an increasingly diverse set of life science domains. At the core of the ISA Commons is the ISA metadata tracking framework which forms the basis for the ISA-TAB-Nano extension. The extension of the ISA framework to nanotechnology domain illustrates the power of a synergistic approach that seeks the interoperability of data across multiple research disciplines. To increase adoption, especially in the commercial arena from vendors and manufactures, the ISA-Tab-Nano data-sharing specification has also been submitted for consideration as a standard to the American Society for Testing and Materials (ASTM). Delivering a community-driven specification is only the first phase of the process. To be useful and used, ISA-TAB-Nano must be implemented by tools and databases to assist researchers in reporting their data accordingly, shielding them from unnecessary complexity. Our next step is to extend the open source ISA Software Suite to provide user-oriented tools for the collection, curation, and storage of data compliant with the ISA-TAB-Nano specification. Future work will also focus on the application of the ISA-TAB-Nano format to support emerging standards on minimal information about nanomaterials in biological research (Ostraat et al, 2012; MinChar). ISA-TAB-Nano development is a community-driven effort and we welcome new contributions, collaborations and domain expertise. We invite researchers, software developers, vendors, and other stakeholders to work with us to implement the ISA-Tab-Nano format in their existing systems and research. Likewise, we welcome engagement of regulators, funding agencies, editors, and other policy makers to discuss how this standard can be used to facilitate the sharing and reuse of nanotechnology data across a wide range of disciplines. More information about the ISA-TAB-Nano project can be found online at https://wiki.nci.nih.gov/display/ICR/ISA-TAB-Nano.« less

  7. Elongated phytoglycogen chain length in transgenic rice endosperm expressing active starch synthase IIa affects the altered solubility and crystallinity of the storage α-glucan

    PubMed Central

    Fujita, Naoko; Toyosawa, Yoshiko; Utsumi, Yoshinori

    2012-01-01

    The relationship between the solubility, crystallinity, and length of the unit chains of plant storage α-glucan was investigated by manipulating the chain length of α-glucans accumulated in a rice mutant. Transgenic lines were produced by introducing a cDNA for starch synthase IIa (SSIIa) from an indica cultivar (SSIIa I, coding for active SSIIa) into an isoamylase1 (ISA1)-deficient mutant (isa1) that was derived from a japonica cultivar (bearing inactive SSIIa proteins). The water-soluble fraction accounted for >95% of the total α-glucan in the isa1 mutant, whereas it was only 35–70% in the transgenic SSIIa I /isa1 lines. Thus, the α-glucans from the SSIIa I /isa1 lines were fractionated into soluble and insoluble fractions prior to the following characterizations. X-ray diffraction analysis revealed a weak B-type crystallinity for the α-glucans of the insoluble fraction, while no crystallinity was confirmed for α-glucans in isa1. Concerning the degree of polymerization (DP) ≤30, the chain lengths of these α-glucans differed significantly in the order of SSIIa I /isa1 insoluble > SSIIa I /isa1 soluble > α-glucans in isa1. The amount of long chains with DP ≥33 was higher in the insoluble fraction α-glucans than in the other two α-glucans. No difference was observed in the chain length distributions of the β-amylase limit dextrins among these α-glucans. These results suggest that in the SSIIa I /isa1 transgenic lines, the unit chains of α-glucans were elongated by SSIIaI, whereas the expression of SSIIaI did not affect the branch positions. Thus, the observed insolubility and crystallinity of the insoluble fraction can be attributed to the elongated length of the outer chains due to SSIIaI. PMID:23048127

  8. Integrated Science Assessment (ISA) for Oxides of Nitrogen ...

    EPA Pesticide Factsheets

    This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision on retaining or revising the current secondary standards for NO2, SO2, PM 2.5 and PM 10 since the prior release of the assessment. The intent of the ISA, according to the CAA, is to “accurately reflect the latest scientific knowledge expected from the presence of [a] pollutant in ambient air” (U.S. Code, 1970a, 1970b). It includes scientific research from atmospheric sciences, exposure and deposition, biogeochemistry, hydrology, soil science, marine science, plant physiology, animal physiology, and ecology conducted at multiple scales (e.g., population, community, ecosystem, landscape levels). Key information and judgments formerly found in the Air Quality Criteria Documents (AQCDs) for oxides of nitrogen, oxides of nitrogen and particulate matter for ecological effects are included; Appendixes provide additional details supporting the ISA. Together, the ISA and Appendixes serve to update and revise the last oxides of nitrogen and oxides of sulfur ISA which was published in 2008 and the ecological portion of the last particulate matter ISA, which was published in 2009.

  9. The RISC-V Instruction Set Manual. Volume 1: User-Level ISA, Version 2.0

    DTIC Science & Technology

    2014-05-06

    x86 architecture (or for that matter, almost every other architecture) is not well supported in the mobile space, though both Intel and ARM are...certain domains, and has to be built for others. • Commercial ISAs come and go. Previous research infrastructures have been built around commercial ISAs...more effort than we had planned at the outset. We have now invested con- siderable effort in building up the RISC-V ISA infrastructure , including

  10. Excretion and toxicity evaluation of 131I-Sennoside A as a necrosis-avid agent.

    PubMed

    Yin, Zhiqi; Sun, Lidan; Jin, Qiaomei; Song, Shaoli; Feng, Yuanbo; Liao, Hong; Ni, Yicheng; Zhang, Jian; Liu, Wei

    2017-11-01

    1. Sennoside A (SA) is a newly identified necrosis-avid agent that shows capability for imaging diagnosis and tumor necrosis targeted radiotherapy. As a water-soluble compound, 131 I-Sennoside A ( 131 I-SA) might be excreted predominately through the kidneys with the possibility of nephrotoxicity. 2. To further verify excretion pathway and examine nephrotoxicity of 131 I-SA, excretion and nephrotoxicity were appraised. The pharmacokinetics, hepatotoxicity and hematotoxicity of 131 I-SA were also evaluated to accelerate its possible clinical translation. All these studies were conducted in mice with ethanol-induced muscular necrosis following a single intravenous administration of 131I-SA at 18.5 MBq/kg or 370 MBq/kg. 3. Excretion data revealed that 131 I-SA was predominately (73.5% of the injected dose (% ID)) excreted via the kidneys with 69.5% ID detected in urine within 72 h post injection. Biodistribution study indicated that 131 I-SA exhibited initial high distribution in the kidneys but subsequently a fast renal clearance, which was further confirmed by the results of autoradiography and single-photon emission computed tomography-computed tomography (SPECT-CT) imaging. The maximum necrotic to normal muscle ratio reached to 7.9-fold at 48 h post injection, which further verified the necrosis avidity of 131 I-SA. Pharmacokinetic parameters showed that 131 I-SA had fast blood clearance with an elimination half-life of 6.7 h. Various functional indexes were no significant difference (p > 0.05) between before administration and 1 d, 8 d, 16 d after administration. Histopathology showed no signs of tissue damage. 4. These data suggest 131 I-SA is a safe and promising necrosis-avid agent applicable in imaging diagnosis and tumor necrosis targeted radiotherapy.

  11. Monothiol glutaredoxin Grx5 interacts with Fe-S scaffold proteins Isa1 and Isa2 and supports Fe-S assembly and DNA integrity in mitochondria of fission yeast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Kyoung-Dong; Chung, Woo-Hyun; Kim, Hyo-Jin

    2010-02-12

    Mitochondrial monothiol glutaredoxins that bind Fe-S cluster are known to participate in Fe-S cluster assembly. However, their precise role has not been well understood. Among three monothiol glutaredoxins (Grx3, 4, and 5) in Schizosaccharomyces pombe only Grx5 resides in mitochondria. The {Delta}grx5 mutant requires cysteine on minimal media, and does not grow on non-fermentable carbon source such as glycerol. We found that the mutant is low in the activity of Fe-S enzymes in mitochondria as well as in the cytoplasm. Screening of multi-copy suppressor of growth defects of the mutant identified isa1{sup +} gene encoding a putative A-type Fe-S scaffold,more » in addition to mas5{sup +} and hsc1{sup +} genes encoding putative chaperones for Fe-S assembly process. Examination of other scaffold and chaperone genes revealed that isa2{sup +}, but not isu1{sup +} and ssc1{sup +}, complemented the growth phenotype of {Delta}grx5 mutant as isa1{sup +} did, partly through restoration of Fe-S enzyme activities. The mutant also showed a significant decrease in the amount of mitochondrial DNA. We demonstrated that Grx5 interacts in vivo with Isa1 and Isa2 proteins in mitochondria by observing bimolecular fluorescence complementation. These results indicate that Grx5 plays a central role in Fe-S assembly process through interaction with A-type Fe-S scaffold proteins Isa1 and Isa2, each of which is an essential protein in S. pombe, and supports mitochondrial genome integrity as well as Fe-S assembly.« less

  12. An analysis of fosaprepitant-induced venous toxicity in patients receiving highly emetogenic chemotherapy

    PubMed Central

    Leal, Alexis D.; Grendahl, Darryl C.; Seisler, Drew K.; Sorgatz, Kristine M.; Anderson, Kari J.; Hilger, Crystal R.; Loprinzi, Charles L.

    2015-01-01

    Purpose Fosaprepitant is an antiemetic used for chemotherapy-induced nausea and vomiting. We recently reported increased infusion site adverse events (ISAE) in a cohort of breast cancer patients receiving chemotherapy with doxorubicin and cyclophosphamide (AC). In this current study, we evaluated the venous toxicity of fosaprepitant use with non-anthracycline platinum-based antineoplastic regimens. Methods A retrospective review was conducted of the first 81 patients initiated on fosaprepitant among patients receiving highly emetogenic chemotherapy, on or after January 1, 2011 at Mayo Clinic Rochester. None of these regimens included an anthracycline. Data collected included baseline demographics, chemotherapy regimen, type of intravenous access and type, and severity of ISAE. Data from these patients were compared to previously collected data from patients who had received AC. Statistical analysis using χ2 and univariate logistic regression was used to evaluate the association between treatment regimen, fosaprepitant, and risk of ISAE. Results Among these 81 patients, the incidence of ISAE was 7.4 % in the non-anthracycline platinum group. The most commonly reported ISAE were swelling (3 %), extravasation (3 %), and phlebitis (3 %). When stratified by regimen, fosaprepitant was associated with a statistically significant increased risk of ISAE in the anthracycline group (OR 8.1; 95 % CI 2.0–31.9) compared to the platinum group. Conclusions Fosaprepitant antiemetic therapy causes significant ISAE that are appreciably higher than previous reports. Patients receiving platinum-based chemotherapy appear to have less significant ISAE than do patients who receive anthracycline-based regimens. PMID:24964876

  13. Fault detection and diagnosis of diesel engine valve trains

    NASA Astrophysics Data System (ADS)

    Flett, Justin; Bone, Gary M.

    2016-05-01

    This paper presents the development of a fault detection and diagnosis (FDD) system for use with a diesel internal combustion engine (ICE) valve train. A novel feature is generated for each of the valve closing and combustion impacts. Deformed valve spring faults and abnormal valve clearance faults were seeded on a diesel engine instrumented with one accelerometer. Five classification methods were implemented experimentally and compared. The FDD system using the Naïve-Bayes classification method produced the best overall performance, with a lowest detection accuracy (DA) of 99.95% and a lowest classification accuracy (CA) of 99.95% for the spring faults occurring on individual valves. The lowest DA and CA values for multiple faults occurring simultaneously were 99.95% and 92.45%, respectively. The DA and CA results demonstrate the accuracy of our FDD system for diesel ICE valve train fault scenarios not previously addressed in the literature.

  14. Silicon micromachined accelerometer/seismometer and method of making the same

    NASA Technical Reports Server (NTRS)

    Martin, Richard D. (Inventor); Pike, W. Thomas (Inventor)

    2001-01-01

    A silicon-based microaccelerometer for seismic application is provided using a low-resonant frequency (10 Hz), large proof mass (1 gram), and high Q suspension to achieve high sensitivity of less than 1 ng with a bandwidth a 0.05 to 50 Hz. The proof mass is cut away from a planar substrate in the form of a disk using abrasive cutting, which disk closely fits but does not touch a surrounding angular frame. The spring of the microaccelerometer between the angular frame and the proof mass is provided from two continuous, 3 microns thick membranes. The fixed capacitive electrodes are provided on separate, subsequently bonded substrates, and movable capacitive plates are provided on the membranes. By fabricating capacitive plates on the separate substrates, the gap between the fixed and movable capacitive plates in the differential capacitive sensor is closely controlled. The use of continuous membranes for the spring produces a shock resistant, robust sensor.

  15. Integrated Science Assessment (ISA) for Lead (First External Review Draft, May 2011)

    EPA Science Inventory

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Lead (Pb) was made available for independent peer review and public review. This draft ISA represents a concise synthesis and evaluation of the most policy-relevant science and will ...

  16. Integrated Science Assessment (ISA) for Carbon Monoxide (Second External Review Draft, Sep 2009)

    EPA Science Inventory

    EPA announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of t...

  17. Integrated Science Assessment (ISA) for Carbon Monoxide (First External Review Draft, Mar 2009)

    EPA Science Inventory

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of th...

  18. Integrated Science Assessment (ISA) for Oxides of Nitrogen – Health Criteria (Second External Review Draft, 2008)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Oxides of Nitrogen – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation...

  19. Integrated Science Assessment (ISA) for Particulate Matter (First External Review Draft, Dec 2008)

    EPA Science Inventory

    EPA has announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Particulate Matter and related Annexes have been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and e...

  20. Integrated Science Assessment (ISA) for Lead (Second External Review Draft, Mar 2012)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Lead (Pb) has been made available for independent peer review and public review. This draft ISA represents a concise synthesis and evaluation of the most policy-relevant science...

  1. Integrated Science Assessment (ISA) for Lead (Third External Review Draft, Nov 2012)

    EPA Science Inventory

    EPA announced that the Third External Review Draft of the Integrated Science Assessment (ISA) for Lead (Pb) was made available for independent peer review and public review. This draft ISA represents a concise synthesis and evaluation of the most policy-relevant science and will ...

  2. Integrated Science Assessment (ISA) for Particulate Matter (Second External Review Draft, Jul 2009)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Particulate Matter (PM) have been made available for independent peer review and public review. The ISA reflects the latest scientific knowledge useful in indicating the kind...

  3. Is Intelligent Speed Adaptation ready for deployment?

    PubMed

    Carsten, Oliver

    2012-09-01

    There have been 30 years of research on Intelligent Speed Adaptation (ISA), the in-vehicle system that is designed to promote compliance with speed limits. Extensive trials of ISA in real-world driving have shown that ISA can significantly reduce speeding, users have been found to have generally positive attitudes and at least some sections of the public have been shown to be willing to purchase ISA systems. Yet large-scale deployment of a system that could deliver huge accident reductions is still by no means guaranteed. Copyright © 2012. Published by Elsevier Ltd.

  4. A user-friendly and scalable process to prepare a ready-to-use inactivated vaccine: the example of heartwater in ruminants under tropical conditions.

    PubMed

    Marcelino, Isabel; Lefrançois, Thierry; Martinez, Dominique; Giraud-Girard, Ken; Aprelon, Rosalie; Mandonnet, Nathalie; Gaucheron, Jérôme; Bertrand, François; Vachiéry, Nathalie

    2015-01-29

    The use of cheap and thermoresistant vaccines in poor tropical countries for the control of animal diseases is a key issue. Our work aimed at designing and validating a process for the large-scale production of a ready-to-use inactivated vaccine for ruminants. Our model was heartwater caused by the obligate intracellular bacterium Ehrlichia ruminantium (ER). The conventional inactivated vaccine against heartwater (based on whole bacteria inactivated with sodium azide) is prepared immediately before injection, using a syringe-extrusion method with Montanide ISA50. This is a fastidious time-consuming process and it limits the number of vaccine doses available. To overcome these issues, we tested three different techniques (syringe, vortex and homogenizer) and three Montanide ISA adjuvants (50, 70 and 70M). High-speed homogenizer was the optimal method to emulsify ER antigens with both ISA70 and 70M adjuvants. The emulsions displayed a good homogeneity (particle size below 1 μm and low phase separation), conductivity below 10 μS/cm and low antigen degradation at 4 °C for up to 1 year. The efficacy of the different formulations was then evaluated during vaccination trials on goats. The inactivated ER antigens emulsified with ISA70 and ISA70M in a homogenizer resulted in 80% and 100% survival rates, respectively. A cold-chain rupture assay using ISA70M+ER was performed to mimic possible field conditions exposing the vaccine at 37 °C for 4 days before delivery. Surprisingly, the animal survival rate was still high (80%). We also observed that the MAP-1B antibody response was very similar between animals vaccinated with ISA70+ER and ISA70M+ER emulsions, suggesting a more homogenous antigen distribution and presentation in these emulsions. Our work demonstrated that the combination of ISA70 or ISA70M and homogenizer is optimal for the production of an effective ready-to-use inactivated vaccine against heartwater, which could easily be produced on an industrial scale. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Adaptive infinite impulse response system identification using modified-interior search algorithm with Lèvy flight.

    PubMed

    Kumar, Manjeet; Rawat, Tarun Kumar; Aggarwal, Apoorva

    2017-03-01

    In this paper, a new meta-heuristic optimization technique, called interior search algorithm (ISA) with Lèvy flight is proposed and applied to determine the optimal parameters of an unknown infinite impulse response (IIR) system for the system identification problem. ISA is based on aesthetics, which is commonly used in interior design and decoration processes. In ISA, composition phase and mirror phase are applied for addressing the nonlinear and multimodal system identification problems. System identification using modified-ISA (M-ISA) based method involves faster convergence, single parameter tuning and does not require derivative information because it uses a stochastic random search using the concepts of Lèvy flight. A proper tuning of control parameter has been performed in order to achieve a balance between intensification and diversification phases. In order to evaluate the performance of the proposed method, mean square error (MSE), computation time and percentage improvement are considered as the performance measure. To validate the performance of M-ISA based method, simulations has been carried out for three benchmarked IIR systems using same order and reduced order system. Genetic algorithm (GA), particle swarm optimization (PSO), cat swarm optimization (CSO), cuckoo search algorithm (CSA), differential evolution using wavelet mutation (DEWM), firefly algorithm (FFA), craziness based particle swarm optimization (CRPSO), harmony search (HS) algorithm, opposition based harmony search (OHS) algorithm, hybrid particle swarm optimization-gravitational search algorithm (HPSO-GSA) and ISA are also used to model the same examples and simulation results are compared. Obtained results confirm the efficiency of the proposed method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  6. Integrated Science Assessment (ISA) for Oxides of Nitrogen – Health Criteria (First External Review Draft, 2007)

    EPA Science Inventory

    EPA has announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Oxides of Nitrogen – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and eva...

  7. Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Environmental Criteria (Second External Review Draft, Aug 2008)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Environmental Criteria has been made available for independent peer review and public review. This draft ISA document represents a conci...

  8. Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria (First External Review Draft, Sep 2007)

    EPA Science Inventory

    EPA has announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluatio...

  9. Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Environmental Criteria (First External Review Draft, Dec 2007)

    EPA Science Inventory

    EPA is announcing that the First External Review Draft of the Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur – Environmental Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise ...

  10. Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria (Second External Review Draft, May 2008)

    EPA Science Inventory

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluati...

  11. Experimental Studies on Dynamic Vibration Absorber using Shape Memory Alloy (NiTi) Springs

    NASA Astrophysics Data System (ADS)

    Kumar, V. Raj; Kumar, M. B. Bharathi Raj; Kumar, M. Senthil

    2011-10-01

    Shape memory alloy (SMA) springs have been used as actuators in many applications although their use in the vibration control area is very recent. Since shape memory alloys differ from conventional alloy materials in many ways, the traditional design approach for springs is not completely suitable for designing SMA springs. Some vibration control concepts utilizing unique characteristics of SMA's will be presented in this paper. A dynamic vibration absorber (DVA) using shape memory alloy (SMA) actuator is developed for attenuation of vibration in a cantilever beam. The design procedure of the DVA is presented. The system consists of a cantilever beam which is considered to generate the real-time vibration using shaker. A SMA spring is used with a mass attached to its end. The stiffness of the SMA spring is dynamically varied in such a way to attenuate the vibration. Both simulation and experimentation are carried out using PID controller. The experiments were carried out by interfacing the experimental setup with a computer using LabVIEW software, Data acquisition and control are implemented using a PCI data acquisition card. Standard PID controllers have been used to control the vibration of the beam. Experimental results are used to demonstrate the effectiveness of the controllers designed and the usefulness of the proposed test platform by exciting the structure at resonance. In experimental setup, an accelerometer is used to measure the vibration which is fed to computer and correspondingly the SMA spring is actuated to change its stiffness to control the vibration. The results obtained illustrate that the developed DVA using SMA actuator is very effective in reducing structural response and have great potential to be an active vibration control medium.

  12. Experimental Studies on Dynamic Vibration Absorber using Shape Memory Alloy (NiTi) Springs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kumar, V. Raj; Kumar, M. B. Bharathi Raj; Kumar, M. Senthil

    2011-10-20

    Shape memory alloy (SMA) springs have been used as actuators in many applications although their use in the vibration control area is very recent. Since shape memory alloys differ from conventional alloy materials in many ways, the traditional design approach for springs is not completely suitable for designing SMA springs. Some vibration control concepts utilizing unique characteristics of SMA's will be presented in this paper.A dynamic vibration absorber (DVA) using shape memory alloy (SMA) actuator is developed for attenuation of vibration in a cantilever beam. The design procedure of the DVA is presented. The system consists of a cantilever beammore » which is considered to generate the real-time vibration using shaker. A SMA spring is used with a mass attached to its end. The stiffness of the SMA spring is dynamically varied in such a way to attenuate the vibration. Both simulation and experimentation are carried out using PID controller. The experiments were carried out by interfacing the experimental setup with a computer using LabVIEW software, Data acquisition and control are implemented using a PCI data acquisition card. Standard PID controllers have been used to control the vibration of the beam. Experimental results are used to demonstrate the effectiveness of the controllers designed and the usefulness of the proposed test platform by exciting the structure at resonance. In experimental setup, an accelerometer is used to measure the vibration which is fed to computer and correspondingly the SMA spring is actuated to change its stiffness to control the vibration. The results obtained illustrate that the developed DVA using SMA actuator is very effective in reducing structural response and have great potential to be an active vibration control medium.« less

  13. Preclinical Vaccine Study of Plasmodium vivax Circumsporozoite Protein Derived-Synthetic Polypeptides Formulated in Montanide ISA 720 and Montanide ISA 51 Adjuvants

    PubMed Central

    Arévalo-Herrera, Myriam; Vera, Omaira; Castellanos, Angélica; Céspedes, Nora; Soto, Liliana; Corradin, Giampietro; Herrera, Sócrates

    2011-01-01

    Plasmodium vivax circumsporozoite (CS) protein is a leading malaria vaccine candidate previously assessed in animals and humans. Here, combinations of three synthetic polypeptides corresponding to amino (N), central repeat (R), and carboxyl (C) regions of the CS protein formulated in Montanide ISA 720 or Montanide ISA 51 adjuvants were assessed for immunogenicity in rodents and primates. BALB/c mice and Aotus monkeys were divided into test and control groups and were immunized three times with doses of 50 and 100 μg of vaccine or placebo. Antigen-specific antimalarial antibodies were determined by enzyme-linked immunosorbent assay, immunofluorescent antibody test, and IFN-γ responses by enzyme-linked immunosorbent spot (ELIspot). Both vaccine formulations were highly immunogenic in both species. Mice developed better antibody responses against C and R polypeptides, whereas the N polypeptide was more immunogenic in monkeys. Anti-peptide antibodies remained detectable for several months and recognized native proteins on sporozoites. Differences between Montanide ISA 720 and Montanide ISA 51 formulations were not significant. PMID:21292874

  14. Integrated Science Assessment (ISA) for Sulfur Oxides ...

    EPA Pesticide Factsheets

    This draft document provides EPA’s evaluation and synthesis of the most policy-relevant science related to the health effects of sulfur oxides. When final, it will provide a critical part of the scientific foundation for EPA’s decision regarding the adequacy of the current primary (health-based) National Ambient Air Quality Standard (NAAQS) for sulfur dioxide. The references considered for inclusion in or cited in the external review draft ISA are available at https://hero.epa.gov/hero/sulfur-oxides. The intent of the ISA, according to the CAA, is to “accurately reflect the latest scientific knowledge expected from the presence of [a] pollutant in ambient air” (U.S. Code, 1970a, 1970b). It includes an assessment of scientific research from atmospheric sciences, exposure sciences, dosimetry, mode of action, animal and human toxicology, and epidemiology. Key information and judgments formerly found in the Air Quality Criteria Documents (AQCDs) for sulfur oxides (SOx) are included; Annexes provide additional details supporting the ISA. Together, the ISA and Annexes serve to update and revise the last SOx ISA which was published in 2008.

  15. ISA 247: trans-ISA 247, trans-R 1524, ISA(TX)247, ISAtx 247, ISATx247, LX 211, LX211, R 1524, R-1524.

    PubMed

    2007-01-01

    Isotechnika is developing the immunosuppressive drug ISA 247, a calcineurin inhibitor that is undergoing clinical development for the treatment of psoriasis (phase III) and prevention of organ rejection after transplantation (phase II). Preclinical development for uveitis is also underway. Other autoimmune disease indications that could be explored include arthritis, type I diabetes and Crohn's disease. ISA 247 was being co-developed as R 1524 by Isotechnika and Roche. However, Roche is no longer involved in the development of this compound. Based on analysis of previously collected data, the trans-ISA 247 isomer was found to be more bioavailable and it is expected that this isomer can be administered at a lower dose compared with the previous formulation that consisted of an equivalent mixture of the two geometric isomers (cis and trans). Preclinical observations indicate that ISA 247 has the potential to be more potent and less toxic than other marketed immunosuppressants in its class used for the prevention of transplant rejection. Experiments to date suggest that ISA 247 is about three times as potent as ciclosporin, while genotoxicity studies in animals have shown that the compound has a significantly reduced tendency to cause renal toxicity. The combination of reduced toxicity and improved potency would give ISA 247 a therapeutic benefit over existing calcineurin-based treatments. Isotechnika and Roche entered into a co-development and commercialisation agreement in April 2002, with Roche gaining the exclusive worldwide marketing rights for ISA 247; Isotechnika received milestone payments of $US4 million and $CAN21.9 million in September 2002 and May 2003, respectively. The agreement was restructured in April 2004, under which Isotechnika will now solely manage and fund the clinical development of trans-ISA 247. Upon successful completion of these trials, Isotechnika will conduct at its own expense a phase IIb study in renal transplantation and phase III studies in psoriasis. Roche will have the right to opt-in to the development and commercialisation of trans-ISA 247 for transplant indications up to the end of the phase IIb renal transplantation trial. Isotechnika retains all rights to develop and commercialise the product outside of transplant indications. Under an agreement signed with Cellgate Inc. on 25 April 2006, Isotechnika has the option to obtain an exclusive licence to develop and commercialise conjugates consisting of Cellgate's patented transporter technology, for the topical delivery of ISA 247 in patients with mild-to-moderate psoriasis. Cellgate will perform studies to evaluate the feasibility of using their technology to topically deliver ISA 247. In return, Isotechnika will pay Cellgate Inc. a total of $US500 000, with $US100 000 paid upfront, and the remainder at predetermined time points. Upon successful completion of the studies, Isotechnika has the option to further develop and commercialise conjugates for topical delivery of ISA 247. Isotechnika and Atrium Medical Corporation announced an exclusive worldwide licensing agreement for ISA 247 alone and in combination with TAFA 93 with respect to drug-eluting devices, in September 2005. Atrium's implantable products include those for the local, non-systemic treatment of vascular and cardiovascular disorders, soft tissue repair and other disorders. In May 2006, Isotechnika licensed ISA 247 to Lux Biosciences for ophthalmic indications. Under terms of the agreement, Lux Biosciences obtains the exclusive worldwide marketing rights to ISA 247 for treatment and prophylaxis of all ophthalmic indications. The company will be responsible for development, registration and marketing of the drug for ophthalmic indications and will make upfront and milestone payments to Isotechnika in addition to royalties on any sales. Isotechnika formalised a manufacturing agreement with Swiss-based Lonza Ltd in June 2004. Under the terms of the agreement, Lonza will manufacture sufficient quantities of trans-ISA 247 in a GMP environment for use in the company's upcoming clinical trials. Isotechnika completed the phase III SPIRIT trial of ISA 247 for psoriasis in Canada. The randomised, double-blind trial compared the efficacy of three doses of ISA 247 (0.2 mg/kg [low dose], 0.3 mg/kg [mid dose] and 0.4 mg/kg [high dose] twice daily) with placebo, with equal numbers of patients assigned to each of the four groups. Subsequent to the first 12 weeks, those patients who received placebo moved into the mid-dose group for the remaining 12 weeks of the study. Patients already receiving ISA 247 remained in their respective dosing groups for the final 12 weeks of the trial. Patients completing the 24-week SPIRIT trial were given the opportunity to continue therapy for an addditonal 36 weeks or to discontinue therapy. Those patients who chose to enrol in the extension trial were moved from the 0.2 mg/kg bid (low-dose) or 0.4 mg/kg bid (high-dose) groups into the the 0.3 bid mg/kg bid (mid dose) group. Patients who commenced the SPIRIT trial in the mid-dose group remained on the same dosage regimen for the duration of the extension trial. The goal of the extension trial is to demonstrate continued therapeutic benefit to psoriasis patients while gathering long-term safety data. So far, data has been received on 193 patients receiving treatment for a total of 48 weeks. A phase IIa trial investigating the safety and efficacy of ISA 247 in renal transplantation was completed in the US and Canada in January 2003. The trial compared ISA 247 with ciclosporin (Neoral in approximately 130 stable renal transplant patients who underwent transplantation at least 6 months prior to enrolment; patient recruitment was completed in October 2002. Half of the patients were treated with ciclosporin and the other half received ISA 247 over a 90-day period. An extension trial was then initiated in which another 200 patients were treated with ISA 247 for up to 6 months from the time of transplantation. Results from the trial were reported. All endpoints were achieved in a multiple ascending dose study of trans-ISA 247 in November 2004. The study, initiated in June 2004, was conducted by SFBC Anapharm in Montreal, Canada and involved 43 healthy volunteers. Final dosing recommendations are to be determined in phase III trials in patients with psoriasis. Interim results reported in September 2004, of a double-blind, parallel-group, placebo and moxifloxacin controlled, randomised single-dose QTc trial in healthy volunteers, showed no evidence of QTc prolongation when trans-ISA 247 was administered at therapeutic doses. A single ascending dose (SAD) trial for trans-ISA 247 was completed in July 2004. The SAD trial was conducted among healthy volunteers to assess the appropriate dosage of trans-ISA 247 for further clinical evaluations. The trial commenced in March 2004 with approximately 46 subjects enrolled under the supervision of MDS Pharma Services in Phoenix, Arizona, USA. Isotechnika received US FDA approval for the SAD trial in February 2004. A European patent (No. EP 0 991 660) entitled 'Deuterated and Undeuterated Cyclosporine Analgoues and Their Use as Immunomodulating Agents' was issued to Isotechnika for ISA 247, in October 2006. A US patent entitled 'Novel Cyclosporin Analogue Formulations' was issued to Isotechnika (No. 7 060 672) for ISA 247 in June 2006. The patent claims have been filed in 36 countries, and in the US it is the first patent to be issued in this patent family. Isotechnika was issued a US patent (No. 6 998 385, entitled 'Cyclosporine Analogue Mixtures and their use as Immunomodulating Agents') in February 2006 covering mixtures of cis- and trans- isomers of ISA 257. This patent is the first US patent to be issued in this family of patents. These patent claims have been filed in 36 countries. Three patents relating to this claim were previously issued in the following countries; Morocco (No. 26337 issued 1 October 2004); Pakistan (No. 138338 issued 30 September 2004) and South Africa (No. 2004/2270 issued 25 May 2005). A US patent (No 6 686 454) was issued in February 2004 entitled 'Antibodies to Specific Regions of Cyclosporine Related Compounds'. This patent covers a novel, simple and cost-effective assay used in the use and management of ISA 247. It also received another US patent entitled 'Deuterated Cyclosporine Analogs and their Use as Immunomodulating Agents'. Isotechnika has received patents for chemical composition of ISA 247 in New Zealand (November 2001; New Zealand Patent No. 502362), Canada (December 2001; Canadian Patent No. 2 298 572), South Korea (June 2006; South Korean Patent No. 585348) and Australia (November 2002; Australian Patent No. 750245). In addition, Isotechnika announced in August 2003 that it had been granted US patent No. 6 605 593, entitled 'Deuterated Ciclosporine Analogs and their use as Immunomodulating Agents'. An additional US patent covering ISA 247 was granted in September 2003.

  16. Principles and frequency of self-adjustment of insulin dose in people with diabetes mellitus type 1 and correlation with markers of metabolic control.

    PubMed

    Kramer, Guido; Kuniss, Nadine; Kloos, Christof; Lehmann, Thomas; Müller, Nicolle; Wolf, Gunter; Lorkowski, Stefan; Müller, Ulrich A

    2016-06-01

    Insulin dose self-adjustment (ISA) to different blood glucose levels, carbohydrate intake, exercise or illness is a core element of structured education programmes for people with diabetes mellitus type 1 (DM1). The aim of this study was to register the patients' current principles and frequency of ISA and to check the ability for correct adjustments. 117 people with DM1 (mean HbA1c 7.1%, diabetes duration 24y) were interviewed in a tertiary care centre. The number of ISA was drawn from the last 28days of the patients' diary. The ability to find the correct insulin dose was assessed using five different calculation examples. All patients had participated in a structured education programme. Mean frequency of ISA was 72.1±29.4 per 28days. ISA by adjustment rules was used in 48% (56/117) and by personal experience or feeling in 44% (52/117). Patients adjusting by feeling were older, did less ISA and had lower social status. There were no differences in HbA1c (feeling 7.2±0.8 vs. rules 7.0±0.9, p=0.403), non severe hypoglycaemia (feeling 1.7±1.8 vs. rules 1.9±1.9, p=0.132) and comprehensibility of ISA between both groups. Overall, the participants answered on average 2.8±2.3 of the five calculation examples correctly. Although all people were trained to use a factor for correction for ISA in case of high premeal blood glucose levels, only half of the patients adjusted their insulin dosage using the complex rules from the treatment and education programme. Patients, who performed their ISA based upon feeling, did not show worse metabolic control. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  17. High-precision and low-cost vibration generator for low-frequency calibration system

    NASA Astrophysics Data System (ADS)

    Li, Rui-Jun; Lei, Ying-Jun; Zhang, Lian-Sheng; Chang, Zhen-Xin; Fan, Kuang-Chao; Cheng, Zhen-Ying; Hu, Peng-Hao

    2018-03-01

    Low-frequency vibration is one of the harmful factors that affect the accuracy of micro-/nano-measuring machines because its amplitude is significantly small and it is very difficult to avoid. In this paper, a low-cost and high-precision vibration generator was developed to calibrate an optical accelerometer, which is self-designed to detect low-frequency vibration. A piezoelectric actuator is used as vibration exciter, a leaf spring made of beryllium copper is used as an elastic component, and a high-resolution, low-thermal-drift eddy current sensor is applied to investigate the vibrator’s performance. Experimental results demonstrate that the vibration generator can achieve steady output displacement with frequency range from 0.6 Hz to 50 Hz, an analytical displacement resolution of 3.1 nm and an acceleration range from 3.72 mm s-2 to 1935.41 mm s-2 with a relative standard deviation less than 1.79%. The effectiveness of the high-precision and low-cost vibration generator was verified by calibrating our optical accelerometer.

  18. Income Share Agreements on Campus: A Practice Guide

    ERIC Educational Resources Information Center

    American Institutes for Research, 2015

    2015-01-01

    Next fall, students at Purdue University may have a new way to pay their tuition: income share agreements (ISAs). ISAs are an alternative form of higher education financing in which students pledge a fixed percentage of future earnings in exchange for money to pay for college. ISAs present a new challenge to the nation's colleges and universities,…

  19. Vaccination with Clostridium perfringens recombinant proteins in combination with Montanide™ ISA 71 VG adjuvant increases protection against experimental necrotic enteritis in commercial broiler chickens

    USDA-ARS?s Scientific Manuscript database

    This study was performed to compare four Clostridium perfringens recombinant proteins as vaccine candidates using the Montanide™ ISA 71 VG adjuvant in an experimental model of necrotic enteritis. Broiler chickens were immunized with clostridial recombinant proteins with ISA 71 VG, and intestinal le...

  20. Auditing SNOMED CT hierarchical relations based on lexical features of concepts in non-lattice subgraphs.

    PubMed

    Cui, Licong; Bodenreider, Olivier; Shi, Jay; Zhang, Guo-Qiang

    2018-02-01

    We introduce a structural-lexical approach for auditing SNOMED CT using a combination of non-lattice subgraphs of the underlying hierarchical relations and enriched lexical attributes of fully specified concept names. Our goal is to develop a scalable and effective approach that automatically identifies missing hierarchical IS-A relations. Our approach involves 3 stages. In stage 1, all non-lattice subgraphs of SNOMED CT's IS-A hierarchical relations are extracted. In stage 2, lexical attributes of fully-specified concept names in such non-lattice subgraphs are extracted. For each concept in a non-lattice subgraph, we enrich its set of attributes with attributes from its ancestor concepts within the non-lattice subgraph. In stage 3, subset inclusion relations between the lexical attribute sets of each pair of concepts in each non-lattice subgraph are compared to existing IS-A relations in SNOMED CT. For concept pairs within each non-lattice subgraph, if a subset relation is identified but an IS-A relation is not present in SNOMED CT IS-A transitive closure, then a missing IS-A relation is reported. The September 2017 release of SNOMED CT (US edition) was used in this investigation. A total of 14,380 non-lattice subgraphs were extracted, from which we suggested a total of 41,357 missing IS-A relations. For evaluation purposes, 200 non-lattice subgraphs were randomly selected from 996 smaller subgraphs (of size 4, 5, or 6) within the "Clinical Finding" and "Procedure" sub-hierarchies. Two domain experts confirmed 185 (among 223) suggested missing IS-A relations, a precision of 82.96%. Our results demonstrate that analyzing the lexical features of concepts in non-lattice subgraphs is an effective approach for auditing SNOMED CT. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Determination of buoyant density and sensitivity to chloroform and freon for the etiological agent of infectious salmonid anaemia

    USGS Publications Warehouse

    Christie, K.E.; Hjeltnes, B.; Uglenes , I.; Winton, J.R.

    1993-01-01

    Plasma was collected from Atlantic salmon Salrno salar with acute infectious salmon anaemia (ISA) and used to challenge Atlantic salmon parr by intraperitoneal injection. Treatment of plasma with the lipid solvent, chloroform, showed that the etiological agent of ISA contained essential lipids, probably as a viral envelope. Some infectivity remained following treatment with freon. Injection challenges using fractions from equilibrium density gradient centrifugation of plasma from fish with acute ISA revealed a band of infectivity in the range 1.184 to 1.262 g cm-3. The band was believed to conta~n both complete ISA-virus particles and infectious particles lacking a complete envelope, nucleocapsid or genome. Density gradient centrifugation of infectious plasma for enrichment of the putative ISA virus appeared to offer a suitable method for obtaining virus-specific nucleic acid for use in the construction of cDNA libraries. 

  2. Phase I Safety and Immunogenicity Trial of Plasmodium vivax CS Derived Long Synthetic Peptides Adjuvanted with Montanide ISA 720 or Montanide ISA 51

    PubMed Central

    Herrera, Sócrates; Fernández, Olga Lucía; Vera, Omaira; Cárdenas, William; Ramírez, Oscar; Palacios, Ricardo; Chen-Mok, Mario; Corradin, Giampietro; Arévalo-Herrera, Myriam

    2011-01-01

    We assessed the safety, tolerability, and immunogenicity of a mixture of three synthetic peptides derived from the Plasmodium vivax circumsporozoite protein formulated in Montanide ISA 720 or Montanide ISA 51. Forty healthy malaria-naive volunteers were allocated to five experimental groups (A–E): four groups (A–D) were immunized intramuscularly with 50 and 100 μg/dose injections of a mixture of N, R, and C peptides formulated in the two different adjuvants at 0, 2, and 4 months and one group was administered placebo. Vaccines were immunogenic, safe, well tolerated, and no serious adverse events related to the vaccine occurred. Seroconversion occurred in > 90% of the vaccines and antibodies recognized the sporozoite protein on immunofluorescent antibody test. Vaccines in Montanide ISA 51 showed a higher sporozoite protein recognition and interferon production. Results encourage further testing of the vaccine protective efficacy. PMID:21292873

  3. One-Year Test-Retest Reliability of the Inventory of Statements about Self-Injury (ISAS)

    ERIC Educational Resources Information Center

    Glenn, Catherine R.; Klonsky, E. David

    2011-01-01

    Nonsuicidal self-injury (NSSI) is a growing public health problem among adolescents and young adults. The Inventory of Statements About Self-Injury (ISAS) is a self-report measure designed to assess NSSI behaviors and functions. The current study examines the one-year test-retest reliability of the ISAS in a sample of young adult self-injurers.…

  4. Montanide ISA 71 VG adjuvant enhances antibody and cell-ediated immune responses to profilin subunit antigen vaccination and promotes protection against Eimeria acervulina and Eimeria tenella

    USDA-ARS?s Scientific Manuscript database

    The present study was conducted to investigate the immunoenhancing effects of ISA 71 VG adjuvant on profilin subunit antigen vaccination. Broiler chickens were immunized subcutaneously with a purified Eimeria acervulina recombinant profilin protein, either alone or mixed with ISA 71 VG, and host imm...

  5. Montanide™ ISA 71 VG adjuvant enhances antibody and cell-mediated immune responses to profilin subunit antigen vaccination and promotes protection against Eimeria acervulina and Eimeria tenella. Experimental Parasitology

    USDA-ARS?s Scientific Manuscript database

    The present study was conducted to investigate the immunoenhancing effects of MontanideTM ISA 71 VG adjuvant on profilin subunit antigen vaccination. Broiler chickens were immunized subcutaneously with a purified Eimeria acervulina recombinant profilin protein, either alone or mixed with ISA 71 VG, ...

  6. Viewpoint on ISA TR84.0.02--simplified methods and fault tree analysis.

    PubMed

    Summers, A E

    2000-01-01

    ANSI/ISA-S84.01-1996 and IEC 61508 require the establishment of a safety integrity level for any safety instrumented system or safety related system used to mitigate risk. Each stage of design, operation, maintenance, and testing is judged against this safety integrity level. Quantitative techniques can be used to verify whether the safety integrity level is met. ISA-dTR84.0.02 is a technical report under development by ISA, which discusses how to apply quantitative analysis techniques to safety instrumented systems. This paper discusses two of those techniques: (1) Simplified equations and (2) Fault tree analysis.

  7. Modernization of Defense Logistics Standard Systems. Establishing the Functional Baseline. Volume 2. Appendix H

    DTIC Science & Technology

    1991-09-01

    and "DD" is the numeric value of the day (01-31). [61 Time ( TM ). The time type is symbolized by the representation " TM ." Format for this type is...VERSION ID M DT 06/06 M TM 04/04 M ID 01/01 M ID 05/05 ISA13 112 ISA14 113 ISA15 114 ISA16 115INTERCHANGE *ACKNOWLEDG. * S1TEST 14 * SUBELEMENT N CTRL...Max - 6 Date of the interchange. DLMS Usage: As above. 109 Interchange Time Type - TM Min - 4 Max - 4 Time of the interchange. DLMS Usage: As above

  8. Surfactant-Enhanced DNAPL Removal

    DTIC Science & Technology

    2001-08-24

    UTCHEM (Run ISA7m) ¥’\\ ~ 10.000 ·, "’" - - UTCHEM (Run ISA26m) ~ ."Q)E ’-,• ....u ’..c: • ••a • ’ .U ,• •~ 1,000.. U...1401301201101009080 -]’" • Field data - UTCHEM (Run ISA26m) 7060 • • 50403020 • 10 1,00 - 1.20 - 0,20 - 0.00 U • · • ••o ,: ,.. Ii I ;. :::S!0 0 c...Concentrations From EXOI 5.0 4.0 • • • . ----- • I - UTCHEM (Run ISA26m) • Field .. , •- 30 • •.. ~u, ti c I , 0 () « 2.0 , • 0.. I , •

  9. Intersectoral action for health equity as it relates to climate change in Canada: contributions from critical systems heuristics.

    PubMed

    Buse, Chris

    2013-12-01

    Intersectoral action (ISA) has been at the forefront of public health policy discussions since the 1970s. ISA incorporates a broader perspective of public health issues and coordinates efforts to address the social, political, economic and environmental contexts from which health determinants operate and are created. Despite being forwarded as a useful way to address and treat complex or 'wicked' problems, such policy issues are still often addressed within, rather than across, disciplinary silos and ISA has been documented to fail more often than it succeeds. This paper contributes to an understanding of ISA by outlining and applying critical systems heuristics (CSH) theory and methods. CSH theory and methods are described and discussed before applying them to the example of addressing climate change and health equity through public health practice. CSH thinking provides useful tools to engage stakeholders, question relations of power that may exist between collaborating partners, and move beyond power inequalities that guide ISA initiatives. CSH is a compelling framing that can improve an understanding of the collaborative relationships that are a prerequisite for engaging in ISA to address complex or 'wicked' policy problems such as climate change. © 2013 John Wiley & Sons Ltd.

  10. A signal-based fault detection and classification method for heavy haul wagons

    NASA Astrophysics Data System (ADS)

    Li, Chunsheng; Luo, Shihui; Cole, Colin; Spiryagin, Maksym; Sun, Yanquan

    2017-12-01

    This paper proposes a signal-based fault detection and isolation (FDI) system for heavy haul wagons considering the special requirements of low cost and robustness. The sensor network of the proposed system consists of just two accelerometers mounted on the front left and rear right of the carbody. Seven fault indicators (FIs) are proposed based on the cross-correlation analyses of the sensor-collected acceleration signals. Bolster spring fault conditions are focused on in this paper, including two different levels (small faults and moderate faults) and two locations (faults in the left and right bolster springs of the first bogie). A fully detailed dynamic model of a typical 40t axle load heavy haul wagon is developed to evaluate the deterioration of dynamic behaviour under proposed fault conditions and demonstrate the detectability of the proposed FDI method. Even though the fault conditions considered in this paper did not deteriorate the wagon dynamic behaviour dramatically, the proposed FIs show great sensitivity to the bolster spring faults. The most effective and efficient FIs are chosen for fault detection and classification. Analysis results indicate that it is possible to detect changes in bolster stiffness of ±25% and identify the fault location.

  11. Tannic acid inhibits Staphylococcus aureus surface colonization in an IsaA-dependent manner.

    PubMed

    Payne, David E; Martin, Nicholas R; Parzych, Katherine R; Rickard, Alex H; Underwood, Adam; Boles, Blaise R

    2013-02-01

    Staphylococcus aureus is a human commensal and pathogen that is capable of forming biofilms on a variety of host tissues and implanted medical devices. Biofilm-associated infections resist antimicrobial chemotherapy and attack from the host immune system, making these infections particularly difficult to treat. In order to gain insight into environmental conditions that influence S. aureus biofilm development, we screened a library of small molecules for the ability to inhibit S. aureus biofilm formation. This led to the finding that the polyphenolic compound tannic acid inhibits S. aureus biofilm formation in multiple biofilm models without inhibiting bacterial growth. We present evidence that tannic acid inhibits S. aureus biofilm formation via a mechanism dependent upon the putative transglycosylase IsaA. Tannic acid did not inhibit biofilm formation of an isaA mutant. Overexpression of wild-type IsaA inhibited biofilm formation, whereas overexpression of a catalytically dead IsaA had no effect. Tannin-containing drinks like tea have been found to reduce methicillin-resistant S. aureus nasal colonization. We found that black tea inhibited S. aureus biofilm development and that an isaA mutant resisted this inhibition. Antibiofilm activity was eliminated from tea when milk was added to precipitate the tannic acid. Finally, we developed a rodent model for S. aureus throat colonization and found that tea consumption reduced S. aureus throat colonization via an isaA-dependent mechanism. These findings provide insight into a molecular mechanism by which commonly consumed polyphenolic compounds, such as tannins, influence S. aureus surface colonization.

  12. Lack of evidence of infectious salmon anemia virus in pollock Pollachius virens cohabitating with infected farmed Atlantic salmon Salmo salar.

    PubMed

    McClure, Carol A; Hammell, K Larry; Dohoo, Ian R; Gagné, Nellie

    2004-10-21

    The infectious salmon anemia (ISA) virus causes lethargy, anemia, hemorrhage of the internal organs, and death in farmed Atlantic salmon Salmo salar. It has been a cause of disease in Norwegian farmed Atlantic salmon since 1984 and has since been identified in Canada, Scotland, the United States, and the Faroe Islands. Wild fish have been proposed as a viral reservoir because they are capable of close contact with farmed salmon. Laboratory studies have shown that brown trout and sea trout Salmo trutta, rainbow trout Oncorhynchus mykiss, and herring Clupea harengus tested positive for the virus weeks after intra-peritoneal injection of the ISA virus. Pollock Pollachius virens are commonly found in and around salmon cages, and their close association with the salmon makes them an important potential viral reservoir to consider. The objective of this study was to determine the presence or prevalence of ISA virus in pollock cohabitating with ISA-infected farmed Atlantic salmon. Kidney tissue from 93 pollock that were living with ISA-infected salmon in sea cages were tested with reverse transcription-polymerase chain reaction (RT-PCR) test. Results yielded the expected 193 bp product for positive controls, while no product was observed in any of the pollock samples, resulting in an ISA viral prevalence of 0%. This study strengthens the evidence that pollock are unlikely to be an ISA virus reservoir for farmed Atlantic salmon.

  13. Commercial Application of In-Space Assembly

    NASA Technical Reports Server (NTRS)

    Lymer, John; Hanson, Mark; Tadros, Al; Boccio, Joel; Hollenstein, Bruno; Emerick, Ken; Doughtery, Sean; Doggett, Bill; Dorsey, John T.; King, Bruce D.; hide

    2016-01-01

    In-Space assembly (ISA) expands the opportunities for cost effective emplacement of systems in space. Currently, spacecraft are launched into space and deploy into their operational configuration through a carefully choreographed sequence of operations. The deployment operation dictates the arrangement of the primary systems on the spacecraft, limiting the ability to take full advantage of launch vehicles volume and mass capability. ISA enables vastly different spacecraft architectures and emplacement scenarios to be achieved, including optimal launch configurations ranging from single launch and assembly to on-orbit aggregation of multiple launches at different orbital locations and times. The spacecraft can be visited at different orbital locations and times to effect expansion and maintenance of an operational capability. To date, the primary application of ISA has been in large programs funded by government organizations, such as the International Space Station. Recently, Space Systems Loral (SSL) led a study funded by the Defense Advanced Research Projects Agency (DARPA), called Dragonfly, to investigate the commercial applicability and economic advantages of ISA. In the study, it was shown that ISA enables SSL to double the capability of a commercial satellite system by taking advantage of alternate packaging approaches for the reflectors. The study included an ultra-light-weight robotic system, derived from Mars manipulator designs, to complete assembly of portions of the antenna system using a tool derived from DARPA orbital express and National Aeronautics and Space Administration (NASA) automated structural assembly experience. The mechanical connector that enables robotic ISA takes advantage of decades of development by NASA from the 1970's to 1980's during the Space Station Freedom program, the precursor to the ISS. The mechanical connector was originally designed for rapid astronaut assembly while also providing a high quality structural connection with linear load deflection response. The paper will discuss the business case for ISA, the general approach taken to exploit on-orbit assembly in the GEO communication satellite market, and the concept of operations associated with the ISA approach, thus laying the foundation for ISA to become an accepted operational approach for commercial in-space operations.

  14. The Risa R/Bioconductor package: integrative data analysis from experimental metadata and back again.

    PubMed

    González-Beltrán, Alejandra; Neumann, Steffen; Maguire, Eamonn; Sansone, Susanna-Assunta; Rocca-Serra, Philippe

    2014-01-01

    The ISA-Tab format and software suite have been developed to break the silo effect induced by technology-specific formats for a variety of data types and to better support experimental metadata tracking. Experimentalists seldom use a single technique to monitor biological signals. Providing a multi-purpose, pragmatic and accessible format that abstracts away common constructs for describing Investigations, Studies and Assays, ISA is increasingly popular. To attract further interest towards the format and extend support to ensure reproducible research and reusable data, we present the Risa package, which delivers a central component to support the ISA format by enabling effortless integration with R, the popular, open source data crunching environment. The Risa package bridges the gap between the metadata collection and curation in an ISA-compliant way and the data analysis using the widely used statistical computing environment R. The package offers functionality for: i) parsing ISA-Tab datasets into R objects, ii) augmenting annotation with extra metadata not explicitly stated in the ISA syntax; iii) interfacing with domain specific R packages iv) suggesting potentially useful R packages available in Bioconductor for subsequent processing of the experimental data described in the ISA format; and finally v) saving back to ISA-Tab files augmented with analysis specific metadata from R. We demonstrate these features by presenting use cases for mass spectrometry data and DNA microarray data. The Risa package is open source (with LGPL license) and freely available through Bioconductor. By making Risa available, we aim to facilitate the task of processing experimental data, encouraging a uniform representation of experimental information and results while delivering tools for ensuring traceability and provenance tracking. The Risa package is available since Bioconductor 2.11 (version 1.0.0) and version 1.2.1 appeared in Bioconductor 2.12, both along with documentation and examples. The latest version of the code is at the development branch in Bioconductor and can also be accessed from GitHub https://github.com/ISA-tools/Risa, where the issue tracker allows users to report bugs or feature requests.

  15. The Risa R/Bioconductor package: integrative data analysis from experimental metadata and back again

    PubMed Central

    2014-01-01

    Background The ISA-Tab format and software suite have been developed to break the silo effect induced by technology-specific formats for a variety of data types and to better support experimental metadata tracking. Experimentalists seldom use a single technique to monitor biological signals. Providing a multi-purpose, pragmatic and accessible format that abstracts away common constructs for describing Investigations, Studies and Assays, ISA is increasingly popular. To attract further interest towards the format and extend support to ensure reproducible research and reusable data, we present the Risa package, which delivers a central component to support the ISA format by enabling effortless integration with R, the popular, open source data crunching environment. Results The Risa package bridges the gap between the metadata collection and curation in an ISA-compliant way and the data analysis using the widely used statistical computing environment R. The package offers functionality for: i) parsing ISA-Tab datasets into R objects, ii) augmenting annotation with extra metadata not explicitly stated in the ISA syntax; iii) interfacing with domain specific R packages iv) suggesting potentially useful R packages available in Bioconductor for subsequent processing of the experimental data described in the ISA format; and finally v) saving back to ISA-Tab files augmented with analysis specific metadata from R. We demonstrate these features by presenting use cases for mass spectrometry data and DNA microarray data. Conclusions The Risa package is open source (with LGPL license) and freely available through Bioconductor. By making Risa available, we aim to facilitate the task of processing experimental data, encouraging a uniform representation of experimental information and results while delivering tools for ensuring traceability and provenance tracking. Software availability The Risa package is available since Bioconductor 2.11 (version 1.0.0) and version 1.2.1 appeared in Bioconductor 2.12, both along with documentation and examples. The latest version of the code is at the development branch in Bioconductor and can also be accessed from GitHub https://github.com/ISA-tools/Risa, where the issue tracker allows users to report bugs or feature requests. PMID:24564732

  16. Mapping Impact of Urbanization in the Continental U.S. from 2001-2020

    NASA Technical Reports Server (NTRS)

    Bounoua, Lahouari; Nigro, Joseph; Zhang, Ping; Thome, Kurtis

    2016-01-01

    Data fusion, from Landsat and MODIS, was used to characterize US buildup and to derive a plausible 2020 impervious surface area (ISA) projection based on observed rates of ISA change as a function of population from 2006 to 2011. The analysis shows that urbanization in the U.S. implicitly includes a cultural character whereby depending on the region, cities are either built horizontally with large ISA per capita or vertically with a minimal spatial footprint. This cultural character can also be forced by land availability, topography and inland water. In other regions, cities seem to have adapted to their population growth and adjusted their ISA use per capita.

  17. A PC based fault diagnosis expert system

    NASA Technical Reports Server (NTRS)

    Marsh, Christopher A.

    1990-01-01

    The Integrated Status Assessment (ISA) prototype expert system performs system level fault diagnosis using rules and models created by the user. The ISA evolved from concepts to a stand-alone demonstration prototype using OPS5 on a LISP Machine. The LISP based prototype was rewritten in C and the C Language Integrated Production System (CLIPS) to run on a Personal Computer (PC) and a graphics workstation. The ISA prototype has been used to demonstrate fault diagnosis functions of Space Station Freedom's Operation Management System (OMS). This paper describes the development of the ISA prototype from early concepts to the current PC/workstation version used today and describes future areas of development for the prototype.

  18. Multilevel adaptive control of nonlinear interconnected systems.

    PubMed

    Motallebzadeh, Farzaneh; Ozgoli, Sadjaad; Momeni, Hamid Reza

    2015-01-01

    This paper presents an adaptive backstepping-based multilevel approach for the first time to control nonlinear interconnected systems with unknown parameters. The system consists of a nonlinear controller at the first level to neutralize the interaction terms, and some adaptive controllers at the second level, in which the gains are optimally tuned using genetic algorithm. The presented scheme can be used in systems with strong couplings where completely ignoring the interactions leads to problems in performance or stability. In order to test the suitability of the method, two case studies are provided: the uncertain double and triple coupled inverted pendulums connected by springs with unknown parameters. The simulation results show that the method is capable of controlling the system effectively, in both regulation and tracking tasks. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Physical exercises for breast cancer survivors: effects of 10 weeks of training on upper limb circumferences

    PubMed Central

    Di Blasio, Andrea; Morano, Teresa; Bucci, Ines; Di Santo, Serena; D’Arielli, Alberto; Castro, Cristina Gonzalez; Cugusi, Lucia; Cianchetti, Ettore; Napolitano, Giorgio

    2016-01-01

    [Purpose] The aims of this study were to verify the effects on upper limb circumferences and total body extracellular water of 10 weeks of Nordic Walking (NW) and Walking (W), both alone and combined with a series of exercises created for breast cancer survivors, the ISA method. [Subjects and Methods] Twenty breast cancer survivors were randomly assigned to 4 different training groups and evaluated for upper limb circumferences, total body and extracellular water. [Results] The breast cancer survivors who performed NW, alone and combined with the ISA method, and Walking combined with the ISA method (but not alone) showed significantly reduced arm and forearm circumferences homolateral to the surgical intervention. [Conclusion] For breast cancer survivors, NW, alone and combined with the ISA method, and Walking combined with the ISA method should be prescribed to prevent the onset and to treat light forms of upper limb lymphedema because Walking training practiced alone had no significant effect on upper limb circumference reduction. PMID:27821934

  20. Radiolytically depolymerized sodium alginate improves physiological activities, yield attributes and composition of essential oil of Eucalyptus citriodora Hook.

    PubMed

    Ali, Akbar; Khan, M Masroor A; Uddin, Moin; Naeem, M; Idrees, Mohd; Hashmi, Nadeem; Dar, Tariq Ahmad; Varshney, Lalit

    2014-11-04

    Eucalyptus citriodora Hook. is highly valued for its citronellal-rich essential oil (EO) extracted from its leaves. Hence, escalated EO production of eucalyptus is the need of hour. Marine polysaccharides (sodium alginate) are processed through gamma radiation of particular intensity, to obtain the irradiated sodium alginate (ISA). A pot experiment was conducted to study the effect of foliar application of ISA on growth, biochemical, physiological, EO yield and composition of E. citriodora. The treatments were applied as: foliar spray of deionized water only (control), seed soaked with ISA (90 mg L(-1)) and foliar spray of ISA with 30, 60, 120 and 240 mg L(-1). The treatment 6 (spray of ISA at 120 mg L(-1)) showed the highest value for most of the parameters studied. It also enhanced the EO content (33.3%), EO yield (86.7%), citronellal content (63.4%) and citronellal yield (205.5%) as compared to the control. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Adapting ISA system warnings to enhance user acceptance.

    PubMed

    Jiménez, Felipe; Liang, Yingzhen; Aparicio, Francisco

    2012-09-01

    Inappropriate speed is a major cause of traffic accidents. Different measures have been considered to control traffic speed, and intelligent speed adaptation (ISA) systems are one of the alternatives. These systems know the speed limits and try to improve compliance with them. This paper deals with an informative ISA system that provides the driver with an advance warning before reaching a road section with singular characteristics that require a lower safe speed than the current speed. In spite of the extensive tests performed using ISA systems, few works show how warnings can be adapted to the driver. This paper describes a method to adapt warning parameters (safe speed on curves, zone of influence of a singular stretch, deceleration process and reaction time) to normal driving behavior. The method is based on a set of tests with and without the ISA system. This adjustment, as well as the analysis of driver acceptance before and after the adaptation and changes in driver behavior (changes in speed and path) resulting from the tested ISA regarding a driver's normal driving style, is shown in this paper. The main conclusion is that acceptance by drivers increased significantly after redefining the warning parameters, but the effect of speed homogenization was not reduced. Copyright © 2010 Elsevier Ltd. All rights reserved.

  2. Mapping Regional Impervious Surface Distribution from Night Time Light: The Variability across Global Cities

    NASA Astrophysics Data System (ADS)

    Lin, M.; Yang, Z.; Park, H.; Qian, S.; Chen, J.; Fan, P.

    2017-12-01

    Impervious surface area (ISA) has become an important indicator for studying urban environments, but mapping ISA at the regional or global scale is still challenging due to the complexity of impervious surface features. The Defense Meteorological Satellite Program's Operational Linescan System (DMSP-OLS) nighttime light data is (NTL) and Resolution Imaging Spectroradiometer (MODIS) are the major remote sensing data source for regional ISA mapping. A single regression relationship between fractional ISA and NTL or various index derived based on NTL and MODIS vegetation index (NDVI) data was established in many previous studies for regional ISA mapping. However, due to the varying geographical, climatic, and socio-economic characteristics of different cities, the same regression relationship may vary significantly across different cities in the same region in terms of both fitting performance (i.e. R2) and the rate of change (Slope). In this study, we examined the regression relationship between fractional ISA and Vegetation Adjusted Nighttime light Urban Index (VANUI) for 120 randomly selected cities around the world with a multilevel regression model. We found that indeed there is substantial variability of both the R2 (0.68±0.29) and slopes (0.64±0.40) among individual regressions, which suggests that multilevel/hierarchical models are needed for accuracy improvement of future regional ISA mapping .Further analysis also let us find the this substantial variability are affected by climate conditions, socio-economic status, and urban spatial structures. However, all these effects are nonlinear rather than linear, thus could not modeled explicitly in multilevel linear regression models.

  3. Tannic Acid Inhibits Staphylococcus aureus Surface Colonization in an IsaA-Dependent Manner

    PubMed Central

    Payne, David E.; Martin, Nicholas R.; Parzych, Katherine R.; Rickard, Alex H.; Underwood, Adam

    2013-01-01

    Staphylococcus aureus is a human commensal and pathogen that is capable of forming biofilms on a variety of host tissues and implanted medical devices. Biofilm-associated infections resist antimicrobial chemotherapy and attack from the host immune system, making these infections particularly difficult to treat. In order to gain insight into environmental conditions that influence S. aureus biofilm development, we screened a library of small molecules for the ability to inhibit S. aureus biofilm formation. This led to the finding that the polyphenolic compound tannic acid inhibits S. aureus biofilm formation in multiple biofilm models without inhibiting bacterial growth. We present evidence that tannic acid inhibits S. aureus biofilm formation via a mechanism dependent upon the putative transglycosylase IsaA. Tannic acid did not inhibit biofilm formation of an isaA mutant. Overexpression of wild-type IsaA inhibited biofilm formation, whereas overexpression of a catalytically dead IsaA had no effect. Tannin-containing drinks like tea have been found to reduce methicillin-resistant S. aureus nasal colonization. We found that black tea inhibited S. aureus biofilm development and that an isaA mutant resisted this inhibition. Antibiofilm activity was eliminated from tea when milk was added to precipitate the tannic acid. Finally, we developed a rodent model for S. aureus throat colonization and found that tea consumption reduced S. aureus throat colonization via an isaA-dependent mechanism. These findings provide insight into a molecular mechanism by which commonly consumed polyphenolic compounds, such as tannins, influence S. aureus surface colonization. PMID:23208606

  4. An Enriched Unified Medical Language System Semantic Network with a Multiple Subsumption Hierarchy

    PubMed Central

    Zhang, Li; Perl, Yehoshua; Halper, Michael; Geller, James; Cimino, James J.

    2004-01-01

    Objective: The Unified Medical Language System's (UMLS's) Semantic Network's (SN's) two-tree structure is restrictive because it does not allow a semantic type to be a specialization of several other semantic types. In this article, the SN is expanded into a multiple subsumption structure with a directed acyclic graph (DAG) IS-A hierarchy, allowing a semantic type to have multiple parents. New viable IS-A links are added as warranted. Design: Two methodologies are presented to identify and add new viable IS-A links. The first methodology is based on imposing the characteristic of connectivity on a previously presented partition of the SN. Four transformations are provided to find viable IS-A links in the process of converting the partition's disconnected groups into connected ones. The second methodology identifies new IS-A links through a string matching process involving names and definitions of various semantic types in the SN. A domain expert is needed to review all the results to determine the validity of the new IS-A links. Results: Nineteen new IS-A links are added to the SN, and four new semantic types are also created to support the multiple subsumption framework. The resulting network, called the Enriched Semantic Network (ESN), exhibits a DAG-structured hierarchy. A partition of the ESN containing 19 connected groups is also derived. Conclusion: The ESN is an expanded abstraction of the UMLS compared with the original SN. Its multiple subsumption hierarchy can accommodate semantic types with multiple parents. Its representation thus provides direct access to a broader range of subsumption knowledge. PMID:14764611

  5. Spatiotemporal dynamics of human settlement patterns in the Southeast U.S. from DMSP/OLS nightlight time series, 1992-2013

    NASA Astrophysics Data System (ADS)

    Wang, C.; Lu, L.

    2015-12-01

    The Southeast U.S. is listed one of the fastest growing regions by the Census Bureau, covering two of the eleven megaregions of the United States (Florida and Piedmont Atlantic). The Defense Meteorological Satellite Program (DMSP)'s Operational Line-scan System (OLS) nighttime light (NTL) imagery offers a good opportunity for characterizing the extent and dynamics of urban development at global and regional scales. However, the commonly used thresholding technique for NTL-based urban land mapping often underestimates the suburban and rural areas and overestimates urban extents. In this study we developed a novel approach to estimating impervious surface area (ISA) by integrating the NTL and optical reflectance data. A geographically weighted regression model was built to extract ISA from the Vegetation-Adjusted NTL Urban Index (VANUI). The ISA was estimated each year from 1992 to 2013 to generate the ISA time series for the U.S. Southeast region. Using the National Land Cover Database (NLCD) products of percent imperviousness (2001, 2006, and 2010) as our reference data, accuracy assessment indicated that our approach made considerable improvement of the ISA estimation, especially in suburban areas. With the ISA time series, a nonparametric Mann-Kendall trend analysis was performed to detect hotspots of human settlement expansion, followed by the exploration of decennial U.S. census data to link these patterns to migration flows in these hotspots. Our results provided significant insights to human settlement of the U.S. Southeast in the past decades. The proposed approach has great potential for mapping ISA at broad scales with nightlight data such as DMSP/OLS and the new-generation VIIRS products. The ISA time series generated in this study can be used to assess the anthropogenic impacts on regional climate, environment and ecosystem services in the U.S. Southeast.

  6. Analysis of isothermal and cooling rate dependent immersion freezing by a unifying stochastic ice nucleation model

    NASA Astrophysics Data System (ADS)

    Alpert, P. A.; Knopf, D. A.

    2015-05-01

    Immersion freezing is an important ice nucleation pathway involved in the formation of cirrus and mixed-phase clouds. Laboratory immersion freezing experiments are necessary to determine the range in temperature (T) and relative humidity (RH) at which ice nucleation occurs and to quantify the associated nucleation kinetics. Typically, isothermal (applying a constant temperature) and cooling rate dependent immersion freezing experiments are conducted. In these experiments it is usually assumed that the droplets containing ice nuclei (IN) all have the same IN surface area (ISA), however the validity of this assumption or the impact it may have on analysis and interpretation of the experimental data is rarely questioned. A stochastic immersion freezing model based on first principles of statistics is presented, which accounts for variable ISA per droplet and uses physically observable parameters including the total number of droplets (Ntot) and the heterogeneous ice nucleation rate coefficient, Jhet(T). This model is applied to address if (i) a time and ISA dependent stochastic immersion freezing process can explain laboratory immersion freezing data for different experimental methods and (ii) the assumption that all droplets contain identical ISA is a valid conjecture with subsequent consequences for analysis and interpretation of immersion freezing. The simple stochastic model can reproduce the observed time and surface area dependence in immersion freezing experiments for a variety of methods such as: droplets on a cold-stage exposed to air or surrounded by an oil matrix, wind and acoustically levitated droplets, droplets in a continuous flow diffusion chamber (CFDC), the Leipzig aerosol cloud interaction simulator (LACIS), and the aerosol interaction and dynamics in the atmosphere (AIDA) cloud chamber. Observed time dependent isothermal frozen fractions exhibiting non-exponential behavior with time can be readily explained by this model considering varying ISA. An apparent cooling rate dependence ofJhet is explained by assuming identical ISA in each droplet. When accounting for ISA variability, the cooling rate dependence of ice nucleation kinetics vanishes as expected from classical nucleation theory. The model simulations allow for a quantitative experimental uncertainty analysis for parameters Ntot, T, RH, and the ISA variability. In an idealized cloud parcel model applying variability in ISAs for each droplet, the model predicts enhanced immersion freezing temperatures and greater ice crystal production compared to a case when ISAs are uniform in each droplet. The implications of our results for experimental analysis and interpretation of the immersion freezing process are discussed.

  7. Enhancing instruction scheduling with a block-structured ISA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melvin, S.; Patt, Y.

    It is now generally recognized that not enough parallelism exists within the small basic blocks of most general purpose programs to satisfy high performance processors. Thus, a wide variety of techniques have been developed to exploit instruction level parallelism across basic block boundaries. In this paper we discuss some previous techniques along with their hardware and software requirements. Then we propose a new paradigm for an instruction set architecture (ISA): block-structuring. This new paradigm is presented, its hardware and software requirements are discussed and the results from a simulation study are presented. We show that a block-structured ISA utilizes bothmore » dynamic and compile-time mechanisms for exploiting instruction level parallelism and has significant performance advantages over a conventional ISA.« less

  8. Sensing and Control Electronics for Low-Mass Low-Capacitance MEMS Accelerometers

    DTIC Science & Technology

    2002-05-01

    R . Lewis (Analog Devices, Inc.) Spring 2002 Report Documentation Page Form ApprovedOMB No. 0704-0188 Public...10 −4 10 −3 Minimum noise floor vs frequency Frequency (Hz) N o is e F lo o r (g / r tH z) 10 4 10 5 10 6 10 7 10 8 40 50 60 70 80 90 100 Optimum...N o is e F lo o r (u g / r tH z) Noise floor vs channel width at 100 KHz 10 1 10 2 10 3 15 20 25 30 35 40 MOSFET Channel Width (um) N o is e F lo

  9. Designing Inhibitors of Cytochrome c/Cardiolipin Peroxidase Complexes: Mitochondria-Targeted Imidazole-Substituted Fatty Acids

    PubMed Central

    Jiang, Jianfei; Bakan, Ahmet; Kapralov, Alexandr A.; Silva, K. Ishara; Huang, Zhentai; Amoscato, Andrew A.; Peterson, James; Garapati, Venkata Krishna; Saxena, Sunil; Bayir, Hülya; Atkinson, Jeffrey; Bahar, Ivet; Kagan, Valerian E.

    2014-01-01

    Mitochondria have emerged as the major regulatory platform responsible for coordination of numerous metabolic reactions as well as cell death processes, whereby the execution of intrinsic apoptosis includes the production of reactive oxygen species fueling oxidation of cardiolipin (CL) catalyzed by cytochrome (cyt) c. As this oxidation occurs within the peroxidase complex of cyt c with CL, the latter represents a promising target for the discovery and design of drugs with anti-apoptotic mechanism of action. In this work, we designed and synthesized a new group of mitochondria-targeted imidazole-substituted analogues of stearic acid TPP-n-ISA with different positions of the attached imidazole group on the fatty acid (n=6, 8, 10, 13 and 14). By using a combination of absorption spectroscopy and EPR protocols (continuous wave electron paramagnetic resonance, and electron spin echo envelope modulation) we demonstrated that TPP-n-ISA indeed were able to potently suppress CL induced structural re-arrangements in cyt c paving the way to its peroxidase competence. TPP-n-ISA analogues preserved the low spin hexa-coordinated heme iron state in cyt c/CL complexes whereby TPP-6-ISA displayed a significantly more effective preservation pattern than TPP-14-ISA. Elucidation of these intermolecular stabilization mechanisms of cyt c identified TPP-6-ISA as an effective inhibitor of the peroxidase function of cyt c/CL complexes with a significant anti-apoptotic potential realized in mouse embryonic cells exposed to ionizing irradiation. These experimental findings were detailed and supported by all atom molecular dynamics simulations. Based on the experimental data and computations predictions, we identified TPP-6-ISA as a candidate drug with optimized anti-apoptotic potency. PMID:24631490

  10. Designing inhibitors of cytochrome c/cardiolipin peroxidase complexes: mitochondria-targeted imidazole-substituted fatty acids.

    PubMed

    Jiang, Jianfei; Bakan, Ahmet; Kapralov, Alexandr A; Silva, K Ishara; Huang, Zhentai; Amoscato, Andrew A; Peterson, James; Garapati, Venkata Krishna; Saxena, Sunil; Bayir, Hülya; Atkinson, Jeffrey; Bahar, Ivet; Kagan, Valerian E

    2014-06-01

    Mitochondria have emerged as the major regulatory platform responsible for the coordination of numerous metabolic reactions as well as cell death processes, whereby the execution of intrinsic apoptosis includes the production of reactive oxygen species fueling oxidation of cardiolipin (CL) catalyzed by cytochrome (Cyt) c. As this oxidation occurs within the peroxidase complex of Cyt c with CL, the latter represents a promising target for the discovery and design of drugs with antiapoptotic mechanisms of action. In this work, we designed and synthesized a new group of mitochondria-targeted imidazole-substituted analogs of stearic acid TPP-n-ISAs with various positions of the attached imidazole group on the fatty acid (n = 6, 8, 10, 13, and 14). By using a combination of absorption spectroscopy and EPR protocols (continuous wave electron paramagnetic resonance and electron spin echo envelope modulation) we demonstrated that TPP-n-ISAs indeed were able to potently suppress CL-induced structural rearrangements in Cyt c, paving the way to its peroxidase competence. TPP-n-ISA analogs preserved the low-spin hexa-coordinated heme-iron state in Cyt c/CL complexes whereby TPP-6-ISA displayed a significantly more effective preservation pattern than TPP-14-ISA. Elucidation of these intermolecular stabilization mechanisms of Cyt c identified TPP-6-ISA as an effective inhibitor of the peroxidase function of Cyt c/CL complexes with a significant antiapoptotic potential realized in mouse embryonic cells exposed to ionizing irradiation. These experimental findings were detailed and supported by all-atom molecular dynamics simulations. Based on the experimental data and computation predictions, we identified TPP-6-ISA as a candidate drug with optimized antiapoptotic potency. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. ISA-TAB-Nano: a specification for sharing nanomaterial research data in spreadsheet-based format.

    PubMed

    Thomas, Dennis G; Gaheen, Sharon; Harper, Stacey L; Fritts, Martin; Klaessig, Fred; Hahn-Dantona, Elizabeth; Paik, David; Pan, Sue; Stafford, Grace A; Freund, Elaine T; Klemm, Juli D; Baker, Nathan A

    2013-01-14

    The high-throughput genomics communities have been successfully using standardized spreadsheet-based formats to capture and share data within labs and among public repositories. The nanomedicine community has yet to adopt similar standards to share the diverse and multi-dimensional types of data (including metadata) pertaining to the description and characterization of nanomaterials. Owing to the lack of standardization in representing and sharing nanomaterial data, most of the data currently shared via publications and data resources are incomplete, poorly-integrated, and not suitable for meaningful interpretation and re-use of the data. Specifically, in its current state, data cannot be effectively utilized for the development of predictive models that will inform the rational design of nanomaterials. We have developed a specification called ISA-TAB-Nano, which comprises four spreadsheet-based file formats for representing and integrating various types of nanomaterial data. Three file formats (Investigation, Study, and Assay files) have been adapted from the established ISA-TAB specification; while the Material file format was developed de novo to more readily describe the complexity of nanomaterials and associated small molecules. In this paper, we have discussed the main features of each file format and how to use them for sharing nanomaterial descriptions and assay metadata. The ISA-TAB-Nano file formats provide a general and flexible framework to record and integrate nanomaterial descriptions, assay data (metadata and endpoint measurements) and protocol information. Like ISA-TAB, ISA-TAB-Nano supports the use of ontology terms to promote standardized descriptions and to facilitate search and integration of the data. The ISA-TAB-Nano specification has been submitted as an ASTM work item to obtain community feedback and to provide a nanotechnology data-sharing standard for public development and adoption.

  12. ISA-TAB-Nano: A Specification for Sharing Nanomaterial Research Data in Spreadsheet-based Format

    PubMed Central

    2013-01-01

    Background and motivation The high-throughput genomics communities have been successfully using standardized spreadsheet-based formats to capture and share data within labs and among public repositories. The nanomedicine community has yet to adopt similar standards to share the diverse and multi-dimensional types of data (including metadata) pertaining to the description and characterization of nanomaterials. Owing to the lack of standardization in representing and sharing nanomaterial data, most of the data currently shared via publications and data resources are incomplete, poorly-integrated, and not suitable for meaningful interpretation and re-use of the data. Specifically, in its current state, data cannot be effectively utilized for the development of predictive models that will inform the rational design of nanomaterials. Results We have developed a specification called ISA-TAB-Nano, which comprises four spreadsheet-based file formats for representing and integrating various types of nanomaterial data. Three file formats (Investigation, Study, and Assay files) have been adapted from the established ISA-TAB specification; while the Material file format was developed de novo to more readily describe the complexity of nanomaterials and associated small molecules. In this paper, we have discussed the main features of each file format and how to use them for sharing nanomaterial descriptions and assay metadata. Conclusion The ISA-TAB-Nano file formats provide a general and flexible framework to record and integrate nanomaterial descriptions, assay data (metadata and endpoint measurements) and protocol information. Like ISA-TAB, ISA-TAB-Nano supports the use of ontology terms to promote standardized descriptions and to facilitate search and integration of the data. The ISA-TAB-Nano specification has been submitted as an ASTM work item to obtain community feedback and to provide a nanotechnology data-sharing standard for public development and adoption. PMID:23311978

  13. U.S. Constructed Area Approaches the Size of Ohio

    NASA Astrophysics Data System (ADS)

    Elvidge, Christopher D.; Milesi, Cristina; Dietz, John B.; Tuttle, Benjamin T.; Sutton, Paul C.; Nemani, Ramakrishna; Vogelmann, James E.

    2004-06-01

    The construction and maintenance of impervious surfaces-buildings, roads, parking lots, roofs, etc.-constitutes a major human alteration of the land surface, changing the local hydrology, climate, and carbon cycling. Three types of national coverage data were used to model the spatial distribution and density of impervious surface area (ISA) for the conterminous U.S.A. The results (Figure 1) indicate that total ISA of the 48 states and Washington, D.C., is 112,610 km2 (+/- 12,725 km2), which is slightly smaller than the state of Ohio (116,534 km2) and slightly larger than the area of herbaceous wetlands (98,460 km2) of the conterminous United States. The same characteristics that make impervious surfaces ideal for use in construction produce a series of effects on the environment. Impervious surfaces alter sensible and latent heat fluxes, causing urban heat islands. In heavily vegetated areas, the proliferation of ISA reduces the sequestration of carbon from the atmosphere. ISA alters the character of watersheds by increasing the frequency and magnitude of surface runoff pulses. Watershed effects of ISA begin to be detectable once 10% of the surface is covered by impervious surfaces, altering the shape of stream channels, raising water temperatures, and sweeping urban debris and pollutants into aquatic environments. Consequences of ISA include reduced numbers and diversity of species in fish and aquatic insects, and degradation of wetlands and riparian zones.

  14. Biodegradation of the alkaline cellulose degradation products generated during radioactive waste disposal.

    PubMed

    Rout, Simon P; Radford, Jessica; Laws, Andrew P; Sweeney, Francis; Elmekawy, Ahmed; Gillie, Lisa J; Humphreys, Paul N

    2014-01-01

    The anoxic, alkaline hydrolysis of cellulosic materials generates a range of cellulose degradation products (CDP) including α and β forms of isosaccharinic acid (ISA) and is expected to occur in radioactive waste disposal sites receiving intermediate level radioactive wastes. The generation of ISA's is of particular relevance to the disposal of these wastes since they are able to form complexes with radioelements such as Pu enhancing their migration. This study demonstrates that microbial communities present in near-surface anoxic sediments are able to degrade CDP including both forms of ISA via iron reduction, sulphate reduction and methanogenesis, without any prior exposure to these substrates. No significant difference (n = 6, p = 0.118) in α and β ISA degradation rates were seen under either iron reducing, sulphate reducing or methanogenic conditions, giving an overall mean degradation rate of 4.7 × 10(-2) hr(-1) (SE ± 2.9 × 10(-3)). These results suggest that a radioactive waste disposal site is likely to be colonised by organisms able to degrade CDP and associated ISA's during the construction and operational phase of the facility.

  15. Development and application of induced-strain actuators for building structures

    NASA Astrophysics Data System (ADS)

    Morita, Koichi; Fujita, Takafumi; Ise, Shiro; Kawaguchi, Ken-ichi; Kamada, Takayoshi; Fujitani, Hideo

    2001-07-01

    Induced strain actuator (ISA) can change their own shapes according to external electric/magnetic fields, and vice versa. Recently these materials have been widely used for the small/precision. The objectives in this study are to develop smart members for building and to realize the smart, comfortable and safe structures. The research items are 1) Semi-active isolation of structures using piezoelectric actuator, 2) Using ISA as sensor materials and 3) Improvement of Acoustic Environment. Semi-active base isolation system with controllable friction damper using piezoelectric actuators is proposed. Simulation study was carried out, and by semi-active isolation, it could be realized to reduce response displacement of the structure to 50% of values of the passive isolation. ISA materials can act as sensors because they cause change of electric or magnetic fields under deformation. PVDF sensors are suitable for membrane structures. We evaluate performance of PVDF sensors for membrane structures by experiment. Polymer based ISA films or distributed ISA devices can control vibration mode of plane members. Applications to music halls or dwelling partition walls are expected. Results of experimental studies of noise control are discussed.

  16. Comparison of apical centring ability between incisal-shifted access and traditional lingual access for maxillary anterior teeth.

    PubMed

    Yahata, Yoshio; Masuda, Yoshiko; Komabayashi, Takashi

    2017-12-01

    The aim of this study was to compare the apical centring ability of incisal-shifted access (ISA) with that of traditional lingual access (TLA). Fifteen three-dimensional printed resin models were prepared from the computed tomography data for a human maxillary central incisor and divided into ISA (n = 7), TLA (n = 7) and control (n = 1) groups. After access preparation, these models were shaped to the working length using K-files up to #40, followed by step-back procedures. An apical portion of the model was removed at 0.5 mm coronal to the working length. Microscopic images of each cutting surface were taken to measure the preparation area and the distance of transportation. TLA created a larger preparation area than ISA (P < 0.05). The distance of transportation (mean ± standard deviation) was 0.4 ± 0.1 mm for ISA and 0.7 ± 0.1 mm for TLA (P < 0.05). Access cavity preparation has a significant effect on apical centring ability. ISA is beneficial to maintaining apical configuration. © 2017 Australian Society of Endodontology Inc.

  17. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET.

    PubMed

    Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D

    2013-03-01

    In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k = 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

  18. Integrated Science Assessment (ISA) for Lead (Second ...

    EPA Pesticide Factsheets

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Lead (Pb) has been made available for independent peer review and public review. This draft ISA represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision regarding whether the current standards for Pb sufficiently protect public health and the environment. Lead (Pb) is one of six principal (or criteria) pollutants for which EPA has established NAAQS

  19. DoD Electronic Data Interchange (EDI) Convention: ASC X12 Transaction Set 836 Contract Award (Version 003010)

    DTIC Science & Technology

    1993-01-01

    upon designation of DoD Activity Address Code (DoDAAC) or other code coordinated with the value-added network (VAN). Mandatory ISA06 106 Interc.ange...coordinated with the value-added network (VAN). Non-DoD activities use identification code qualified by ISA05 and coordinated with the VAN. Mandatory...designation of DoD Activity Address Code (DoDAAC) or other code coordinated with the value-added network (VAN). Mandatory ISA08 107 Interchange Receiver

  20. Bi-spectrum based-EMD applied to the non-stationary vibration signals for bearing faults diagnosis.

    PubMed

    Saidi, Lotfi; Ali, Jaouher Ben; Fnaiech, Farhat

    2014-09-01

    Empirical mode decomposition (EMD) has been widely applied to analyze vibration signals behavior for bearing failures detection. Vibration signals are almost always non-stationary since bearings are inherently dynamic (e.g., speed and load condition change over time). By using EMD, the complicated non-stationary vibration signal is decomposed into a number of stationary intrinsic mode functions (IMFs) based on the local characteristic time scale of the signal. Bi-spectrum, a third-order statistic, helps to identify phase coupling effects, the bi-spectrum is theoretically zero for Gaussian noise and it is flat for non-Gaussian white noise, consequently the bi-spectrum analysis is insensitive to random noise, which are useful for detecting faults in induction machines. Utilizing the advantages of EMD and bi-spectrum, this article proposes a joint method for detecting such faults, called bi-spectrum based EMD (BSEMD). First, original vibration signals collected from accelerometers are decomposed by EMD and a set of IMFs is produced. Then, the IMF signals are analyzed via bi-spectrum to detect outer race bearing defects. The procedure is illustrated with the experimental bearing vibration data. The experimental results show that BSEMD techniques can effectively diagnosis bearing failures. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  1. Anoxic Biodegradation of Isosaccharinic Acids at Alkaline pH by Natural Microbial Communities.

    PubMed

    Rout, Simon P; Charles, Christopher J; Doulgeris, Charalampos; McCarthy, Alan J; Rooks, Dave J; Loughnane, J Paul; Laws, Andrew P; Humphreys, Paul N

    2015-01-01

    One design concept for the long-term management of the UK's intermediate level radioactive wastes (ILW) is disposal to a cementitious geological disposal facility (GDF). Under the alkaline (10.013.0) anoxic conditions expected within a GDF, cellulosic wastes will undergo chemical hydrolysis. The resulting cellulose degradation products (CDP) are dominated by α- and β-isosaccharinic acids (ISA), which present an organic carbon source that may enable subsequent microbial colonisation of a GDF. Microcosms established from neutral, near-surface sediments demonstrated complete ISA degradation under methanogenic conditions up to pH 10.0. Degradation decreased as pH increased, with β-ISA fermentation more heavily influenced than α-ISA. This reduction in degradation rate was accompanied by a shift in microbial population away from organisms related to Clostridium sporosphaeroides to a more diverse Clostridial community. The increase in pH to 10.0 saw an increase in detection of Alcaligenes aquatilis and a dominance of hydrogenotrophic methanogens within the Archaeal population. Methane was generated up to pH 10.0 with acetate accumulation at higher pH values reflecting a reduced detection of acetoclastic methanogens. An increase in pH to 11.0 resulted in the accumulation of ISA, the absence of methanogenesis and the loss of biomass from the system. This study is the first to demonstrate methanogenesis from ISA by near surface microbial communities not previously exposed to these compounds up to and including pH 10.0.

  2. On-line I-/Te- separation for the AMS analysis of 125I

    NASA Astrophysics Data System (ADS)

    Charles, C. R. J.; Cornett, R. J.; Zhao, X.-L.; Litherland, A. E.; Kieser, W. E.

    2015-10-01

    The isobar separator for anions (ISA) was used together with a 3 MV tandem accelerator mass spectrometer (AMS) to demonstrate the real time (on-line) separation of Te- from I-. Following the ion source mass spectrometry and major retardation to tens of eV, the ISA uses a radiofrequency quadrupole (RFQ) ion guide to confine and direct I- and associated Te- isobar anions through a gas-reaction cell, where chemical reactions occur at eV energies with the electronegative gas NO2. Anions are subsequently reaccelerated out of the ISA to near original ion source extraction energies for AMS analysis. At 5 mTorr NO2 in the ISA gas-reaction cell, 125Te- was observed to be attenuated by a factor of ∼107 as compared to 127I- that did not experience significant (<50%) losses. A comparative test using 37Cl- and 32S- (having similar chemical properties to iodine and tellurium) showed a 32S- attenuation of >107 relative to 37Cl- under the same ISA-AMS conditions. The preferential destruction of Te- (and S-) at eV energies in the ISA is likely due to a larger favorable destruction cross-section with NO2. This study is the first demonstration of I-Te anion separation for AMS, and makes possible the use of 125I, free of the contaminant 125Te isobar after suitable sample purification, for future 129I/125I carrier-free analyses of natural samples at ultra-low trace levels.

  3. Infectious salmon anaemia virus (ISAV) in Chilean Atlantic salmon (Salmo salar) aquaculture: emergence of low pathogenic ISAV-HPR0 and re-emergence of virulent ISAV-HPR∆: HPR3 and HPR14.

    PubMed

    Godoy, Marcos G; Kibenge, Molly J T; Suarez, Rudy; Lazo, Eduardo; Heisinger, Alejandro; Aguinaga, Javier; Bravo, Diego; Mendoza, Julio; Llegues, Katerina O; Avendaño-Herrera, Rubén; Vera, Cristian; Mardones, Fernando; Kibenge, Frederick S B

    2013-11-23

    Infectious salmon anaemia (ISA) is a serious disease of marine-farmed Atlantic salmon (Salmo salar) caused by ISA virus (ISAV), which belongs to the genus Isavirus, family Orthomyxoviridae. ISA is caused by virulent ISAV strains with deletions in a highly polymorphic region (HPR) of the hemagglutinin-esterase (HE) protein (designated virulent ISAV-HPR∆). This study shows the historic dynamics of ISAV-HPR∆ and ISAV-HPR0 in Chile, the genetic relationship among ISAV-HPR0 reported worldwide and between ISAV-HPR0 and ISAV-HPR∆ in Chile, and reports the 2013 ISA outbreak in Chile. The first ISA outbreak in Chile occurred from mid-June 2007 to 2010 and involved the virulent ISAV-HPR7b, which was then replaced by a low pathogenic ISAV-HPR0 variant. We analyzed this variant in 66 laboratory-confirmed ISAV-HPR0 cases in Chile in comparison to virulent ISAV-HPR∆ that caused two new ISA outbreaks in April 2013. Multiple alignment and phylogenetic analysis of HE sequences from all ISAV-HPR0 viruses allowed us to identify three genomic clusters, which correlated with three residue patterns of ISAV-HPR0 (360PST362, 360PAN362 and 360PAT362) in HPR. The virus responsible for the 2013 ISAV-HPR∆ cases in Chile belonged to ISAV-HPR3 and ISAV-HPR14, and in phylogenetic analyses, both clustered with the ISAV-HPR0 found in Chile. The ISAV-HPR14 had the ISAV-HPR0 residue pattern 360PAT362, which is the only type of ISAV-HPR0 variant found in Chile. This suggested to us that the 2013 ISAV-HPR∆ re-emerged from ISAV-HPR0 that is enzootic in Chilean salmon aquaculture and were not new introductions of virulent ISAV-HPR∆ to Chile. The clinical presentations and diagnostic evidence of the 2013 ISA cases indicated a mixed infection of ISAV with the ectoparasite Caligus rogercresseyi and the bacterium Piscirickettsia salmonis, which underscores the need for active ISAV surveillance in areas where ISAV-HPR0 is enzootic, to ensure early detection and control of new ISA outbreaks, as it is considered a risk factor. This is the first report of ISA linked directly to the presence of ISAV-HPR0, and provides strong evidence supporting the contention that ISAV-HPR0 shows a strong relationship to virulent ISAV-HPR∆ viruses and the possibility that it could mutate to virulent ISAV-HPR∆.

  4. Infectious salmon anaemia virus (ISAV) in Chilean Atlantic salmon (Salmo salar) aquaculture: emergence of low pathogenic ISAV-HPR0 and re-emergence of virulent ISAV-HPR∆: HPR3 and HPR14

    PubMed Central

    2013-01-01

    Abstact Infectious salmon anaemia (ISA) is a serious disease of marine-farmed Atlantic salmon (Salmo salar) caused by ISA virus (ISAV), which belongs to the genus Isavirus, family Orthomyxoviridae. ISA is caused by virulent ISAV strains with deletions in a highly polymorphic region (HPR) of the hemagglutinin-esterase (HE) protein (designated virulent ISAV-HPR∆). This study shows the historic dynamics of ISAV-HPR∆ and ISAV-HPR0 in Chile, the genetic relationship among ISAV-HPR0 reported worldwide and between ISAV-HPR0 and ISAV-HPR∆ in Chile, and reports the 2013 ISA outbreak in Chile. The first ISA outbreak in Chile occurred from mid-June 2007 to 2010 and involved the virulent ISAV-HPR7b, which was then replaced by a low pathogenic ISAV-HPR0 variant. We analyzed this variant in 66 laboratory-confirmed ISAV-HPR0 cases in Chile in comparison to virulent ISAV-HPR∆ that caused two new ISA outbreaks in April 2013. Multiple alignment and phylogenetic analysis of HE sequences from all ISAV-HPR0 viruses allowed us to identify three genomic clusters, which correlated with three residue patterns of ISAV-HPR0 (360PST362, 360PAN362 and 360PAT362) in HPR. The virus responsible for the 2013 ISAV-HPR∆ cases in Chile belonged to ISAV-HPR3 and ISAV-HPR14, and in phylogenetic analyses, both clustered with the ISAV-HPR0 found in Chile. The ISAV-HPR14 had the ISAV-HPR0 residue pattern 360PAT362, which is the only type of ISAV-HPR0 variant found in Chile. This suggested to us that the 2013 ISAV-HPR∆ re-emerged from ISAV-HPR0 that is enzootic in Chilean salmon aquaculture and were not new introductions of virulent ISAV-HPR∆ to Chile. The clinical presentations and diagnostic evidence of the 2013 ISA cases indicated a mixed infection of ISAV with the ectoparasite Caligus rogercresseyi and the bacterium Piscirickettsia salmonis, which underscores the need for active ISAV surveillance in areas where ISAV-HPR0 is enzootic, to ensure early detection and control of new ISA outbreaks, as it is considered a risk factor. This is the first report of ISA linked directly to the presence of ISAV-HPR0, and provides strong evidence supporting the contention that ISAV-HPR0 shows a strong relationship to virulent ISAV-HPR∆ viruses and the possibility that it could mutate to virulent ISAV-HPR∆. PMID:24268071

  5. An ISA-TAB-Nano based data collection framework to support data-driven modelling of nanotoxicology.

    PubMed

    Marchese Robinson, Richard L; Cronin, Mark T D; Richarz, Andrea-Nicole; Rallo, Robert

    2015-01-01

    Analysis of trends in nanotoxicology data and the development of data driven models for nanotoxicity is facilitated by the reporting of data using a standardised electronic format. ISA-TAB-Nano has been proposed as such a format. However, in order to build useful datasets according to this format, a variety of issues has to be addressed. These issues include questions regarding exactly which (meta)data to report and how to report them. The current article discusses some of the challenges associated with the use of ISA-TAB-Nano and presents a set of resources designed to facilitate the manual creation of ISA-TAB-Nano datasets from the nanotoxicology literature. These resources were developed within the context of the NanoPUZZLES EU project and include data collection templates, corresponding business rules that extend the generic ISA-TAB-Nano specification as well as Python code to facilitate parsing and integration of these datasets within other nanoinformatics resources. The use of these resources is illustrated by a "Toy Dataset" presented in the Supporting Information. The strengths and weaknesses of the resources are discussed along with possible future developments.

  6. An ISA-TAB-Nano based data collection framework to support data-driven modelling of nanotoxicology

    PubMed Central

    Marchese Robinson, Richard L; Richarz, Andrea-Nicole; Rallo, Robert

    2015-01-01

    Summary Analysis of trends in nanotoxicology data and the development of data driven models for nanotoxicity is facilitated by the reporting of data using a standardised electronic format. ISA-TAB-Nano has been proposed as such a format. However, in order to build useful datasets according to this format, a variety of issues has to be addressed. These issues include questions regarding exactly which (meta)data to report and how to report them. The current article discusses some of the challenges associated with the use of ISA-TAB-Nano and presents a set of resources designed to facilitate the manual creation of ISA-TAB-Nano datasets from the nanotoxicology literature. These resources were developed within the context of the NanoPUZZLES EU project and include data collection templates, corresponding business rules that extend the generic ISA-TAB-Nano specification as well as Python code to facilitate parsing and integration of these datasets within other nanoinformatics resources. The use of these resources is illustrated by a “Toy Dataset” presented in the Supporting Information. The strengths and weaknesses of the resources are discussed along with possible future developments. PMID:26665069

  7. Integrated Science Assessment (ISA) for Sulfur Oxides ...

    EPA Pesticide Factsheets

    EPA has announced that the Second External Review Draft of the Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision regarding whether the current standard for SO2 sufficiently protects public health. Sulfur oxides is one of six principal (or “criteria”) pollutants for which EPA has established national ambient air quality standards (NAAQS).

  8. Integrated Science Assessment (ISA) for Sulfur Oxides ...

    EPA Pesticide Factsheets

    EPA has announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria has been made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision regarding whether the current standard for SO2 sufficiently protects public health. Sulfur oxides is one of six principal (or “criteria”) pollutants for which EPA has established national ambient air quality standards (NAAQS).

  9. SU-D-17A-02: Four-Dimensional CBCT Using Conventional CBCT Dataset and Iterative Subtraction Algorithm of a Lung Patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hu, E; Lasio, G; Yi, B

    2014-06-01

    Purpose: The Iterative Subtraction Algorithm (ISA) method generates retrospectively a pre-selected motion phase cone-beam CT image from the full motion cone-beam CT acquired at standard rotation speed. This work evaluates ISA method with real lung patient data. Methods: The goal of the ISA algorithm is to extract motion and no- motion components form the full reconstruction CBCT. The workflow consists of subtracting from the full CBCT all of the undesired motion phases and obtain a motion de-blurred single-phase CBCT image, followed by iteration of this subtraction process. ISA is realized as follows: 1) The projections are sorted to various phases,more » and from all phases, a full reconstruction is performed to generate an image CTM. 2) Generate forward projections of CTM at the desired phase projection angles, the subtraction of projection and the forward projection will reconstruct a CTSub1, which diminishes the desired phase component. 3) By adding back the CTSub1 to CTm, no motion CBCT, CTS1, can be computed. 4) CTS1 still contains residual motion component. 5) This residual motion component can be further reduced by iteration.The ISA 4DCBCT technique was implemented using Varian Trilogy accelerator OBI system. To evaluate the method, a lung patient CBCT dataset was used. The reconstruction algorithm is FDK. Results: The single phase CBCT reconstruction generated via ISA successfully isolates the desired motion phase from the full motion CBCT, effectively reducing motion blur. It also shows improved image quality, with reduced streak artifacts with respect to the reconstructions from unprocessed phase-sorted projections only. Conclusion: A CBCT motion de-blurring algorithm, ISA, has been developed and evaluated with lung patient data. The algorithm allows improved visualization of a single phase motion extracted from a standard CBCT dataset. This study has been supported by National Institute of Health through R01CA133539.« less

  10. Evidence of the Generation of Isosaccharinic Acids and Their Subsequent Degradation by Local Microbial Consortia within Hyper-Alkaline Contaminated Soils, with Relevance to Intermediate Level Radioactive Waste Disposal

    PubMed Central

    Rout, Simon P.; Charles, Christopher J.; Garratt, Eva J.; Laws, Andrew P.; Gunn, John; Humphreys, Paul N.

    2015-01-01

    The contamination of surface environments with hydroxide rich wastes leads to the formation of high pH (>11.0) soil profiles. One such site is a legacy lime works at Harpur Hill, Derbyshire where soil profile indicated in-situ pH values up to pH 12. Soil and porewater profiles around the site indicated clear evidence of the presence of the α and β stereoisomers of isosaccharinic acid (ISA) resulting from the anoxic, alkaline degradation of cellulosic material. ISAs are of particular interest with regards to the disposal of cellulosic materials contained within the intermediate level waste (ILW) inventory of the United Kingdom, where they may influence radionuclide mobility via complexation events occurring within a geological disposal facility (GDF) concept. The mixing of uncontaminated soils with the alkaline leachate of the site resulted in ISA generation, where the rate of generation in-situ is likely to be dependent upon the prevailing temperature of the soil. Microbial consortia present in the uncontaminated soil were capable of surviving conditions imposed by the alkaline leachate and demonstrated the ability to utilise ISAs as a carbon source. Leachate-contaminated soil was sub-cultured in a cellulose degradation product driven microcosm operating at pH 11, the consortia present were capable of the degradation of ISAs and the generation of methane from the resultant H2/CO2 produced from fermentation processes. Following microbial community analysis, fermentation processes appear to be predominated by Clostridia from the genus Alkaliphilus sp, with methanogenesis being attributed to Methanobacterium and Methanomassiliicoccus sp. The study is the first to identify the generation of ISA within an anthropogenic environment and advocates the notion that microbial activity within an ILW-GDF is likely to influence the impact of ISAs upon radionuclide migration. PMID:25748643

  11. Evidence of the generation of isosaccharinic acids and their subsequent degradation by local microbial consortia within hyper-alkaline contaminated soils, with relevance to intermediate level radioactive waste disposal.

    PubMed

    Rout, Simon P; Charles, Christopher J; Garratt, Eva J; Laws, Andrew P; Gunn, John; Humphreys, Paul N

    2015-01-01

    The contamination of surface environments with hydroxide rich wastes leads to the formation of high pH (>11.0) soil profiles. One such site is a legacy lime works at Harpur Hill, Derbyshire where soil profile indicated in-situ pH values up to pH 12. Soil and porewater profiles around the site indicated clear evidence of the presence of the α and β stereoisomers of isosaccharinic acid (ISA) resulting from the anoxic, alkaline degradation of cellulosic material. ISAs are of particular interest with regards to the disposal of cellulosic materials contained within the intermediate level waste (ILW) inventory of the United Kingdom, where they may influence radionuclide mobility via complexation events occurring within a geological disposal facility (GDF) concept. The mixing of uncontaminated soils with the alkaline leachate of the site resulted in ISA generation, where the rate of generation in-situ is likely to be dependent upon the prevailing temperature of the soil. Microbial consortia present in the uncontaminated soil were capable of surviving conditions imposed by the alkaline leachate and demonstrated the ability to utilise ISAs as a carbon source. Leachate-contaminated soil was sub-cultured in a cellulose degradation product driven microcosm operating at pH 11, the consortia present were capable of the degradation of ISAs and the generation of methane from the resultant H2/CO2 produced from fermentation processes. Following microbial community analysis, fermentation processes appear to be predominated by Clostridia from the genus Alkaliphilus sp, with methanogenesis being attributed to Methanobacterium and Methanomassiliicoccus sp. The study is the first to identify the generation of ISA within an anthropogenic environment and advocates the notion that microbial activity within an ILW-GDF is likely to influence the impact of ISAs upon radionuclide migration.

  12. SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Safigholi, H; Soliman, A; Song, W

    Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summedmore » using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.« less

  13. Assessment of the spatial accessibility to health professionals at French census block level.

    PubMed

    Gao, Fei; Kihal, Wahida; Le Meur, Nolwenn; Souris, Marc; Deguen, Séverine

    2016-08-02

    The evaluation of geographical healthcare accessibility in residential areas provides crucial information to public policy. Traditional methods - such as Physician Population Ratios (PPR) or shortest travel time - offer only a one-dimensional view of accessibility. This paper developed an improved indicator: the Index of Spatial Accessibility (ISA) to measure geographical healthcare accessibility at the smallest available infra-urban level, that is, the Îlot Regroupé pour des Indicateurs Statistiques. This study was carried out in the department of Nord, France. Healthcare professionals are geolocalized using postal addresses available on the French state health insurance website. ISA is derived from an Enhanced Two-Step Floating Catchment Area (E2FCA). We have constructed a catchment for each healthcare provider, by taking into account residential building centroids, car travel time as calculated by Google Maps and the edge effect. Principal Component Analyses (PCA) were used to build a composite ISA to describe the global accessibility of different kinds of health professionals. We applied our method to studying geographical healthcare accessibility for pregnant women, by selecting three types of healthcare provider: general practitioners, gynecologists and midwives. A total of 3587 healthcare providers are potentially able to provide care for inhabitants of the department of Nord. On average there are 92 general practitioners, 22 midwives and 21 gynecologists per 100,000 residents. The composite ISA for the three types of healthcare provider is 39 per 100,000 residents. A comparative analysis between ISA and physician-population ratios indicates that ISA represents a more even distribution whereas the physician-population ratios show an 'all-or-nothing' approach. ISA is a multidimensional and improved measure, which combines the volume of services relative to population size with the proximity of services relative to the population's location, available at the smallest feasible geographical scale. It could guide policy makers towards highlighting critical areas in need of more healthcare providers, and these areas should be earmarked for further knowledge-based policy making.

  14. "Fly-by-Wireless" Vehicles and Evaluations of ISA 100 Applications to Space-Flight

    NASA Technical Reports Server (NTRS)

    Studor, George F.

    2009-01-01

    "Fly-by-Wireless" (What is it?) Vision: To minimize cables and connectors and increase functionality across the aerospace industry by providing reliable, lower cost, modular, and higher performance alternatives to wired data connectivity to benefit the entire vehicle/program life-cycle. Focus Areas: 1. System Engineering and Integration to reduce cables and connectors. 2. Provisions for modularity and accessibility in the vehicle architecture. 3. Develop Alternatives to wired connectivity (the "tool box").NASA and Aerospace depend more and more on cost-effective solutions that can meet our requirements. ISA-100.11 a is a promising new standard and NASA wants to evaluate it. NASA should be involved in understanding and contributing to other ISA-100 efforts that contribute to "Fly-by-Wireless" and it's objectives. ISA can engage other aerospace groups that are working on similar goals and obtain more aerospace industry perspective.

  15. Terrorism reports: The tip of the iceberg.

    PubMed

    Ellenberg, Eytan; Taragin, Mark; Bar-On, Zvia; Cohen, Osnat; Ostfeld, Ishay

    2017-01-01

    Medical impact of terror is a public health issue as the threat is growing all over the world. Our objective was to compare the number of injured and incidents in the three different databases and reports [Global Terrorism Database (GTD), Israeli Security Agency (ISA) and National Insurance Institute (NII)] in Israel. Retrospective study. Analyses of three different databases (GTD, ISA and NII) and basic comparison. The victims reimbursed for medical expenses are the largest population. The number of injured as described by GTD and ISA database are less important. The 2010-2013 years are marked by more incidents recognized in Israel vs GTD assessment (except in 2014). The number of victims being reimbursed for medical and mental health services is radically different from the GTD and the ISA reports. Public Health specialists should be advised of this phenomenon to deliver their right approach (including mental health) to growing threat and develop new definition of victim of terror.

  16. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced that the First External Review Draft of the Integrated Science Assessment (ISA) for Carbon Monoxide (CO) and related Annexes was made available for independent peer review and public review. This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA's decision regarding whether the current standards for CO sufficiently protect public health and the environment. The Integrated Plan for Review of the NAAQS for CO {U.S. EPA, 2008 #8615} identifies key policy-relevant questions that provide a framework for this review of the scientific evidence. These questions frame the entire review of the NAAQS, and thus are informed by both science and policy considerations. The ISA organizes and presents the scientific evidence such that it, when considered along with findings from risk analyses and policy considerations, will help the EPA address these questions during the NAAQS review:

  17. Can Cyberloafing and Internet Addiction Affect Organizational Information Security?

    PubMed

    Hadlington, Lee; Parsons, Kathryn

    2017-09-01

    Researchers have noted potential links between Internet addiction, the use of work computers for nonwork purposes and an increased risk of threat to the organization from breaches in cybersecurity. However, much of this research appears conjectural in nature and lacks clear empirical evidence to support such claims. To fill this knowledge gap, a questionnaire-based study explored the link between cyberloafing, Internet addiction, and information security awareness (ISA). A total of 338 participants completed an online questionnaire, which comprised of the Online Cognition Scale, Cyberloafing Scale, and the Human Aspects of Information Security Questionnaire. Participants who reported higher Internet addiction and cyberloafing tendencies had lower ISA, and Internet addiction and cyberloafing predicted a significant 45 percent of the variance in ISA. Serious cyberloafing, such as the propensity to visit adult websites and online gambling, was shown to be the significant predictor for poorer ISA. Implications for organizations and recommendations to reduce or manage inappropriate Internet use are discussed.

  18. Intraseptal vs. periodontal ligament anaesthesia for maxillary tooth extraction: quality of local anaesthesia and haemodynamic response.

    PubMed

    Brkovic, Bozidar M B; Savic, Miroslav; Andric, Miroslav; Jurisic, Milan; Todorovic, Ljubomir

    2010-12-01

    There is no data concerning the use of the intraseptal anaesthesia (ISA) for single tooth extraction. The aims of this study were to compare the clinical efficacy and haemodynamic responses of the ISA with the periodontal ligament anaesthesia (PLA) for single tooth extraction. Thirty-five randomly selected healthy patients (ASA I) undergoing maxillary lateral incisors extraction entered the study. Onset of anaesthesia, the width of the anaesthetic field and duration of anaesthesia were recorded by pinprick testing. Intensity of anaesthesia was evaluated on a visual analogue scale. Haemodynamic parameters were recorded simultaneously at different time points after anaesthesia injection. The two techniques of local anaesthesia did not show statistically significant differences regarding the success rate and onset of anaesthesia, while the duration of the ISA on the buccal site was significantly longer in comparison with the PLA. The intensity of the achieved anaesthesia, estimated by the experienced pain during procedure, pointed out that pain was recorded in 24% of cases in the ISA group, and in 19% in the PLA group without significant differences. Postoperative pain was found to be smaller in the ISA group (70.9% of treated sites) than in the PLA group (81.3% of treated sites); however, this difference was not significant. Although the heart rate increased in both groups, there were no significant differences in the patients' haemodynamic response between the ISA and the PLA. The results of the present study indicate that both techniques are useful and suitable for the routine tooth extraction.

  19. Relative Bioavailability of Silybin A and Silybin B From 2 Multiconstituent Dietary Supplement Formulations Containing Milk Thistle Extract: A Single-dose Study.

    PubMed

    Li, Wen-Yi; Yu, Guo; Hogan, Renee M; Mohandas, Rajesh; Frye, Reginald F; Gumpricht, Eric; Markowitz, John S

    2018-01-01

    The purpose of this study was to compare the bioavailability between 2 milk thistle-containing dietary supplements, Product B and IsaGenesis, in healthy volunteers. Bioavailability between Product B, originally formulated as a powdered capsule, and IsaGenesis, reformulated as a soft gel, were compared by measuring silybin A and silybin B as surrogate pharmacokinetic markers for differences in absorption and bioavailability. For this randomized, open-label, crossover pharmacokinetic study, 12 healthy volunteers consumed a single-dose serving of each supplement separated by at least a 7-day washout period. Serial blood samples were obtained at 0, 0.5, 1, 1.5, 2, 3, 4, 6, and 8 hours and analyzed via LC-MS/MS. Rapid absorption and elimination of silybin A and silybin B have been observed after oral administration of both Product B and IsaGenesis. However, the absorption rate and extent, as indicated by mean the C max and mean plasma AUC, were significantly higher for the IsaGenesis soft gel formulation. The dose-corrected mean C max was 365% and 450% greater for silybin A and B, respectively, relative to powdered Product B. The time to T max was reached, on average, at least 1 hour earlier with IsaGenesis relative to Product B for both silybin A and silybin B. The IsaGenesis soft gel formulation provided substantially greater absorption and bioavailability of silybin A and silybin B relative to the powdered Product B supplement. ClinicalTrials.gov Identifier: NCT02529605. Copyright © 2018 Elsevier HS Journals, Inc. All rights reserved.

  20. Comparative genomics identifies candidate genes for infectious salmon anemia (ISA) resistance in Atlantic salmon (Salmo salar).

    PubMed

    Li, Jieying; Boroevich, Keith A; Koop, Ben F; Davidson, William S

    2011-04-01

    Infectious salmon anemia (ISA) has been described as the hoof and mouth disease of salmon farming. ISA is caused by a lethal and highly communicable virus, which can have a major impact on salmon aquaculture, as demonstrated by an outbreak in Chile in 2007. A quantitative trait locus (QTL) for ISA resistance has been mapped to three microsatellite markers on linkage group (LG) 8 (Chr 15) on the Atlantic salmon genetic map. We identified bacterial artificial chromosome (BAC) clones and three fingerprint contigs from the Atlantic salmon physical map that contains these markers. We made use of the extensive BAC end sequence database to extend these contigs by chromosome walking and identified additional two markers in this region. The BAC end sequences were used to search for conserved synteny between this segment of LG8 and the fish genomes that have been sequenced. An examination of the genes in the syntenic segments of the tetraodon and medaka genomes identified candidates for association with ISA resistance in Atlantic salmon based on differential expression profiles from ISA challenges or on the putative biological functions of the proteins they encode. One gene in particular, HIV-EP2/MBP-2, caught our attention as it may influence the expression of several genes that have been implicated in the response to infection by infectious salmon anemia virus (ISAV). Therefore, we suggest that HIV-EP2/MBP-2 is a very strong candidate for the gene associated with the ISAV resistance QTL in Atlantic salmon and is worthy of further study.

  1. Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria (Final)

    EPA Science Inventory

    The SOx ISA reviews information on atmospheric science, exposure, dosimetry, mode of action, and health effects related to sulfur oxides and sulfur dioxide (SO2), including evidence from controlled human exposure, epidemiologic, and toxicological studies.

  2. 76 FR 58509 - Release of Risk and Exposure Assessment Planning Document for the Review of the National Ambient...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-21

    ... ISA) provides support for the development of quantitative assessments of risk and exposure for health... conclusions presented in the First Draft ISA provide support for the development of quantitative assessments...

  3. Whole-Genome Sequence of the Anaerobic Isosaccharinic Acid Degrading Isolate, Macellibacteroides fermentans Strain HH-ZS

    PubMed Central

    Rout, Simon P.; Salah, Zohier B.; Charles, Christopher J.

    2017-01-01

    Abstract The ability of micro-organisms to degrade isosaccharinic acids (ISAs) while tolerating hyperalkaline conditions is pivotal to our understanding of the biogeochemistry associated within these environs, but also in scenarios pertaining to the cementitious disposal of radioactive wastes. An alkalitolerant, ISA degrading micro-organism was isolated from the hyperalkaline soils resulting from lime depositions. Here, we report the first whole-genome sequence, ISA degradation profile and carbohydrate preoteome of a Macellibacteroides fermentans strain HH-ZS, 4.08 Mb in size, coding 3,241 proteins, 64 tRNA, and 1 rRNA. PMID:28859355

  4. Pay as You Speed, ISA with incentives for not speeding: a case of test driver recruitment.

    PubMed

    Lahrmann, Harry; Agerholm, Niels; Tradisauskas, Nerius; Næss, Teresa; Juhl, Jens; Harms, Lisbeth

    2012-09-01

    The Intelligent Speed Adaptation (ISA) project we describe in this article is based on Pay as You Drive principles. These principles assume that the ISA equipment informs a driver of the speed limit, warns the driver when speeding and calculates penalty points. Each penalty point entails the reduction of a 30% discount on the driver's car insurance premium, which therefore produced the name, Pay as You Speed. The ISA equipment consists of a GPS-based On Board Unit with a mobile phone connection to a web server. The project was planned for a three-year test period with 300 young car drivers, but it never succeeded in recruiting that number of drivers. After several design changes, the project eventually went forward with 153 test drivers of all ages. This number represents approximately one thousandth of all car owners in the proving ground of North Jutland in Denmark. Furthermore the project was terminated before its scheduled closing date. This article describes the project with an emphasis on recruitment efforts and the project's progress. We include a discussion of possible explanations for the failure to recruit volunteers for the project and reflect upon the general barriers to using ISA with ordinary drivers. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. The occurrence of early impaired self-awareness after traumatic brain injury and its relationship with emotional distress and psychosocial functioning.

    PubMed

    Geytenbeek, Megan; Fleming, Jennifer; Doig, Emmah; Ownsworth, Tamara

    2017-01-01

    To describe the occurrence of impaired self-awareness (ISA) after traumatic brain injury (TBI) and its association with emotional distress and psychosocial functioning following discharge. Prospective cohort design with data collection at discharge and 1-, 3- and 6-month follow-up. 81 adults with TBI. Self-awareness was measured using a discrepancy score generated from the Mayo-Portland Adaptability Index (MPAI-4) Ability subscale, and significant other's ratings of Item 20 on the MPAI-4. Other measures were the Depression Anxiety Stress Scale-21 and Sydney Psychosocial and Reintegration Scale. The discrepancy score method identified more cases of ISA than the single-item rating by significant others. Using discrepancy scores, the occurrence of ISA was 69.1% at discharge, and for those remaining in the study 6 months later, it was 54.3%. Better self-awareness was associated with greater anxiety at discharge, and stress at discharge, 3 and 6 months later, and better psychosocial functioning at all time points. Participants with ISA had significantly poorer relationships at 6 months post-discharge after controlling for injury severity. Whilst self-awareness is associated with greater stress in patients with TBI, it is also associated with better outcomes, indicating the importance of targeting ISA in rehabilitation.

  6. Identification and characterization of antimicrobial peptides from the skin of the endangered frog Odorrana ishikawae.

    PubMed

    Iwakoshi-Ukena, Eiko; Ukena, Kazuyoshi; Okimoto, Aiko; Soga, Miyuki; Okada, Genya; Sano, Naomi; Fujii, Tamotsu; Sugawara, Yoshiaki; Sumida, Masayuki

    2011-04-01

    The endangered anuran species, Odorrana ishikawae, is endemic to only two small Japanese Islands, Amami and Okinawa. To assess the innate immune system in this frog, we investigated antimicrobial peptides in the skin using artificially bred animals. Nine novel antimicrobial peptides containing the C-terminal cyclic heptapeptide domain were isolated on the basis of antimicrobial activity against Escherichia coli. The peptides were members of the esculentin-1 (two peptides), esculentin-2 (one peptide), palustrin-2 (one peptide), brevinin-2 (three peptides) and nigrocin-2 (two peptides) antimicrobial peptide families. They were named esculentin-1ISa, esculentin-1ISb, esculentin-2ISa, palustrin-2ISa, brevinin-2ISa, brevinin-2ISb, brevinin-2ISc, nigrocin-2ISa and nigrocin-2ISb. Peptide primary structures suggest a close relationship with the Asian odorous frogs, Odorrana grahami and Odorrana hosii. These antimicrobial peptides possessed a broad-spectrum of growth inhibition against five microorganisms (E. coli, Staphylococcus aureus, methicillin-resistant S. aureus, Bacillus subtilis and Candida albicans). Nine different cDNAs encoding the precursor proteins were also cloned and showed that the precursor proteins exhibited a signal peptide, an N-terminal acidic spacer domain, a Lys-Arg processing site and an antimicrobial peptide at the C-terminus. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. A Microseismometer for Terrestrial and Extraterrestrial Applications

    NASA Technical Reports Server (NTRS)

    Banerdt, W.; Kaiser, W.; Vanzandt, T.

    1993-01-01

    The scientific and technical requirements of extraterrestrial seismology place severe demands on instrumentation. Performance in terms of sensitivity, stability, and frequency band must match that of the best terrestrial instruments, at a fraction of the size, mass, and power. In addition, this performance must be realized without operator intervention in harsh temperature, shock, and radiation environments. These constraints have forced us to examine some fundamental limits of accelerometer design in order to produce a small, rugged, sensitive seismometer. Silicon micromachined sensor technology offers techniques for the fabrication of monolithic, robust, compact, low-power and -mass accelerometers. However, currently available sensors offer inadequate sensitivity and bandwidth. Our implementation of an advanced silicon micro machined seismometer is based on principles developed at JPL for high-sensitivity position sensor technology. The use of silicon micro machining technology with these new principles should enable the fabrication of a 10(exp -11) g sensitivity seismometer with a bandwidth of at least 0.01 to 20 Hz. The low Q properties of pure single-crystal silicon are essential in order to minimize the Brownian thermal noise limitations generally characteristic of seismometers with small proof masses. A seismometer consists of a spring-supported proof mass and a transducer for measuring its motion. For long period motion a position sensor is generally used, for which the displacement is proportional to the ground acceleration. The mechanical sensitivity can be increased either by increasing the proof mass or decreasing the spring stiffness, neither of which is desirable for planetary applications. Our approach has been to use an ultra sensitive capacitive position sensor with a sensitivity of better than 10(exp -13) m/Hz(exp 1/2). This allows the use of a stiffer suspension and a smaller proof mass. We have built several prototypes using these principles, and tests show that these devices can exhibit performance comparable to state-of-the-art instruments.

  8. Simultaneous silencing of isoamylases ISA1, ISA2 and ISA3 by multi-target RNAi in potato tubers leads to decreased starch content and an early sprouting phenotype

    PubMed Central

    Ferreira, Stephanus J.; Senning, Melanie; Fischer-Stettler, Michaela; Streb, Sebastian; Ast, Michelle; Neuhaus, H. Ekkehard; Zeeman, Samuel C.; Sonnewald, Sophia

    2017-01-01

    Isoamylases hydrolyse (1–6)-alpha-D-glucosidic linkages in starch and are involved in both starch granule formation and starch degradation. In plants, three isoamylase isoforms with distinct functions in starch synthesis (ISA1 and ISA2) and degradation (ISA3) have been described. Here, we created transgenic potato plants with simultaneously decreased expression of all three isoamylases using a chimeric RNAi construct targeting all three isoforms. Constitutive expression of the hairpin RNA using the 35S CaMV promoter resulted in efficient silencing of all three isoforms in leaves, growing tubers, and sprouting tubers. Neither plant growth nor tuber yield was effected in isoamylase-deficient potato lines. Interestingly, starch metabolism was found to be impaired in a tissue-specific manner. While leaf starch content was unaffected, tuber starch was significantly reduced. The reduction in tuber starch content in the transgenic plants was accompanied by a decrease in starch granules size, an increased sucrose content and decreased hexose levels. Despite the effects on granule size, only little changes in chain length composition of soluble and insoluble glucose polymers were detected. The transgenic tubers displayed an early sprouting phenotype that was accompanied by an increased level of sucrose in parenchyma cells below the outgrowing bud. Since high sucrose levels promote sprouting, we propose that the increased number of small starch granules may cause an accelerated turnover of glucan chains and hence a more rapid synthesis of sucrose. This observation links alterations in starch structure/degradation with developmental processes like meristem activation and sprout outgrowth in potato tubers. PMID:28708852

  9. [Interdisciplinary pain assessment in the hospital setting : Merely a door-opener to multimodal pain therapy?

    PubMed

    Sens, E; Mothes-Lasch, M; Lutz, J F

    2017-12-01

    Chronic pain is characterized by a complex interaction of somatic, mental and social factors. Assessing these factors in patients with chronic pain is vital during the diagnostic work-up and when making a structured treatment plan. Interdisciplinary pain assessment (ISA) is the most promising method to deal with these challenges. This article presents our experience in performing pain assessments in the hospital setting and also illustrates the characteristic features of chronic pain patients undergoing such assessments. This study reviews and evaluates patient data from 2704 ISAs performed at the Interdisciplinary Pain Centre of the Zentralklinik Bad Berka, Germany, between 2008 and 2015. The majority of our ISA patients are severely handicapped and show distinct signs of chronic disease. A large proportion of patients is either unable to work or receiving benefits (invalidity pension or retirement pension). In addition, patients reported long disease durations and high emotional distress. Treatment recommendations were based on the patients' individual clinical presentations and examination results. More than half of the patients required multimodal pain management, while adjustments or therapeutic withdrawal of pain medications, in particular of opioids, were indicated in many patients. Our study shows that ISA enables fast, high-quality diagnostic assessments of chronic pain while taking the biopsychosocial model of pain in particular into account. In addition, ISA is not biased with regard to outcome results and recommends the further treatment that appears best for the individual patient. ISA leads not only to inpatient treatment, but also to treatment in other therapeutic settings and, as such, is not merely a door-opener to multimodal pain therapy.

  10. Immunization with antigenic extracts of Leishmania associated with Montanide ISA 763 adjuvant induces partial protection in BALB/c mice against Leishmania (Leishmania) amazonensis infection.

    PubMed

    Cargnelutti, Diego Esteban; Salomón, María Cristina; Celedon, Verónica; García Bustos, María Fernanda; Morea, Gastón; Cuello-Carrión, Fernando Darío; Scodeller, Eduardo Alberto

    2016-02-01

    A proper adjuvant has a relevant role in vaccine formulations to generate an effective immune response. In this study, total Leishmania antigen (TLA) formulated with Montanide ISA 763 or R848 as adjuvants were evaluated as a first generation Leishmania vaccine in a murine model. Immunization protocols were tested in BALB/c mice with a subcutaneous prime/boost regimen with an interval of 3 weeks. Mice immunized with unadjuvanted TLA and phosphate-buffered saline (PBS) served as control groups. On Day 21 and Day 36 of the protocol, we evaluated the humoral immune response induced by each formulation. Fifteen days after the boost, the immunized mice were challenged with 1 × 10(5) promastigotes of Leishmania (Leishmania) amazonensis in the right footpad (RFP). The progress of the infection was followed for 10 weeks; at the end of this period, histopathological studies were performed in the RFP. Vaccines formulated with Montanide ISA 763 generated an increase in the production of immunoglobulin G (IgG; p < 0.05) compared with the control group. There were no statistically significant differences in IgG1 production between the study groups. However, immunization with TLA-Montanide ISA 763 resulted in an increase in IgG2a compared to the unadjuvanted control (p < 0.001). Also noteworthy was the fact that a significant reduction in swelling and histopathological damage of the RFP was recorded with the Montanide ISA 763 formulation. We conclude that the immunization of BALB/c mice with a vaccine formulated with TLA and Montanide ISA 763 generated a protective immune response against L. (L.) amazonensis, characterized by an intense production of IgG2a. Copyright © 2014. Published by Elsevier B.V.

  11. Effects of indirubin and isatin on cell viability, mutagenicity, genotoxicity and BAX/ERCC1 gene expression.

    PubMed

    Fogaça, Manoela Viar; Cândido-Bacani, Priscila de Matos; Benicio, Lucas Milanez; Zapata, Lara Martinelli; Cardoso, Priscilla de Freitas; de Oliveira, Marcelo Tempesta; Calvo, Tamara Regina; Varanda, Eliana Aparecida; Vilegas, Wagner; de Syllos Cólus, Ilce Mara

    2017-12-01

    Indigofera suffruticosa Miller (Fabaceae) and I. truxillensis Kunth produce compounds, such as isatin (ISA) and indirubin (IRN), which possess antitumour properties. Their effects in mammalian cells are still not very well understood. We evaluated the activities of ISA and/or IRN on cell viability and apoptosis in vitro, their genotoxic potentials in vitro and in vivo, and the IRN- and ISA-induced expression of ERCC1 or BAX genes. HeLa and/or CHO-K1 cell lines were tested (3 or 24 h) in the MTT, Trypan blue exclusion, acridine orange/ethidium bromide, cytokinesis-blocked micronucleus (CBMN) and comet (36, 24 and 72 h) tests after treatment with IRN (0.1 to 200 μM) or ISA (0.5 to 50 μM). Gene expression was measured by RT-qPCR in HeLa cells. Swiss albino mice received IRN (3, 4 or 24 h) by gavage (50, 100 and 150 mg/kg determined from the LD 50 - 1 g/kg b.w.) and submitted to comet assay in vivo. IRN reduced the viability of CHO-K1 (24 h; 5 to 200 μM) and HeLa cells (10 to 200 μM), and was antiproliferative in the CBMN test (CHO-K1: 0.5 to 10 μM; HeLa: 5 and 10 μM). The drug did not induce apoptosis, micronucleus neither altered gene expression. IRN and ISA were genotoxic for HeLa cells (3 and 24 h) at all doses tested. IRN (100 and 150 mg/kg) also induced genotoxicity in vivo (4 h). IRN and ISA have properties that make them candidates as chemotherapeutics for further pharmacological investigations.

  12. Deployment technique that takes advantage of the characteristics of Enterprise VRD2: an in vitro study.

    PubMed

    Chihara, Hideo; Ishii, Akira; Kikuchi, Takayuki; Ikeda, Hiroyuki; Arai, Daisuke; Miyamoto, Susumu

    2017-10-01

    Enterprise VRD, a stent frequently used to assist coil embolization of cerebral aneurysms, has been upgraded to reduce the risk of incomplete stent apposition (ISA), a known risk factor for thromboembolic complications. To compare the performances of Enterprise VRD and Enterprise VRD2 in curved vessels, and to investigate a deployment method that takes advantage of the features of Enterprise VRD2 to achieve better vessel wall apposition. A silicone vascular model connected to a temperature-adjustable perfusion circuit was used. First, Enterprise VRD and Enterprise VRD2 were deployed under fluoroscopy and then ISA was evaluated as the stent cross-sectional area ratio at the curved segment of the vessel. For the measurements, each stent was deployed in vessels with different angles of curvature. Second, the incidence of ISA after insertion of Enterprise VRD2 by the 'pushing over outer curve technique', in which stents are deployed along the outer curve of vessels with continuous wire advancement, was compared with 'Heller's push and pull technique'. For all stents, the cross-sectional area ratio decreased with acute curvature of the vessel. Comparisons of the two stents showed that Enterprise VRD2 was better than Enterprise VRD in maintaining a greater cross-sectional area ratio in curved vessels. In addition, kinking with an acute curvature was also minimized with Enterprise VRD2. Furthermore, ISA was reduced using our technique with Enterprise VRD2. Enterprise VRD2 is superior to Enterprise VRD in reducing ISA in curved vessels and can alter ISA according to the deployment technique used. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. 77 FR 3226 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-23

    ...: Infectious Salmon Anemia (ISA)--Payment of Indemnity. OMB Control Number: 0579-0192. Summary of Collection... eradicate pest or diseases of livestock or poultry. Infectious Salmon Anemia (ISA) poses a substantial..., anemia, and lethargy. The Animal and Plant Health Inspection Service (APHIS) will collect information...

  14. Integrated Science Assessment (ISA) for Lead (Final Report, Jul 2013)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Lead (Pb). This document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision regard...

  15. A programmable ISA to USB interface

    NASA Astrophysics Data System (ADS)

    Ribas, R. V.

    2013-05-01

    A programmable device to access and control ISA-standard camac instrumentation and interfacing it to the USB port of computers, is described in this article. With local processing capabilities and event buffering before sending data to the computer, the new acquisition system become much more efficient.

  16. A Limitation of the Applicability of Interval Shift Analysis to Program Evaluation

    ERIC Educational Resources Information Center

    Hardy, Roy

    1975-01-01

    Interval Shift Analysis (ISA) is an adaptation of the linear programming model used to determine maximum benefits or minimal losses in quantifiable economics problems. ISA is applied to pre and posttest score distributions for 43 classes of second graders. (RC)

  17. Automated feedback to foster safe driving in young drivers : Phase 2.

    DOT National Transportation Integrated Search

    2015-12-01

    Intelligent Speed Adaptation (ISA) represents a promising approach to reduce speeding. A core principle for ISA systems is that they provide real-time feedback to drivers, prompting them to reduce speed when some threshold at or above the limit is re...

  18. Deal or no deal: can incentives encourage widespread adoption of intelligent speed adaptation devices?

    PubMed

    Chorlton, Kathryn; Hess, Stephane; Jamson, Samantha; Wardman, Mark

    2012-09-01

    Given the burden of injury, economic, environmental and social consequences associated with speeding, reducing road traffic speed remains a major priority. Intelligent speed adaptation (ISA) is a promising but controversial new in-vehicle system that provides drivers with support on the speed-control task. In order to model potential system uptake, this paper explores drivers' preferences for two different types of ISA given a number of alternative fiscal incentives and non-fiscal measures, using a stated preference approach. As would be expected with such a contentious issue, the analysis revealed the presence of significant variations in sensitivities and preferences in the sample. While a non-negligible part of the sample population has such strong opposition to ISA that no reasonable discounts or incentives would lead to them buying or accepting such a system, there is also a large part of the population that, if given the right incentives, would be willing or even keen to equip their vehicle with an ISA device. Copyright © 2011. Published by Elsevier Ltd.

  19. Detecting ongoing intimate partner violence in the emergency department using a simple 4-question screen: the OVAT.

    PubMed

    Ernst, Amy A; Weiss, Steven J; Cham, Elaine; Hall, Louise; Nick, Todd G

    2004-06-01

    We wanted to prospectively evaluate the use of a brief screening tool for ongoing intimate partner violence (IPV), the OVAT, and to validate this tool against the present Index of Spouse Abuse (ISA). The design was a prospective survey during randomized 4-hour shifts in an urban emergency department setting. The scale consists of four questions developed based on our previous work. The ISA was compared as the gold standard for detection of present (ongoing) IPV. Of 362 eligible patients presenting during 75 randomized 4-hour shifts, 306 (85%) completed the study. The prevalence of ongoing IPV using the OVAT was 31% (95% CI 26% to 36%). For the ISA, the prevalence was 20% (95% CI 16% to 25%). Compared with the ISA, the sensitivity of the OVAT in detecting ongoing IPV was 86%, specificity 83%, negative predictive value 96%, positive predictive value 56%, with an accuracy of 84%. In conclusion, four brief questions can detect ongoing IPV to aid in identifying the victim.

  20. Strain variation, based on the hemagglutinin gene, in Norwegian ISA virus isolates collected from 1987 to 2001: indications of recombination.

    PubMed

    Devold, M; Falk, K; Dale, B; Krossøy, B; Biering, E; Aspehaug, V; Nilsen, F; Nylund, A

    2001-11-08

    Infectious salmon anemia (ISA) is caused by a virus that probably belongs to the Orthomyxoviridae and was first recorded in Norway in 1984. The disease has since spread along the Norwegian coast and has later been found in Canada, Scotland, the Faroe Islands, Chile, and the USA. This study presents sequence variation of the hemagglutinin gene from 37 ISA virus isolates, viz. one isolate from Scotland, one from Canada and 35 from Norway. The hemagglutinin gene contains a highly polymorphic region (HPR), which together with the rest of the gene sequence provides a good tool for studies of epizootics. The gene shows temporal and geographical sequence variation, where certain areas are dominated by distinct groups of isolates. Evidence of transmission of ISA virus isolates within and between regions is given. It is suggested that the hemagglutinin gene from different isolates may recombine. Possible recombination sites are found within the HPR and in the 5'-end flanking region close to the HPR.

  1. Fabrication of a Miniaturized ZnO Nanowire Accelerometer and Its Performance Tests

    PubMed Central

    Kim, Hyun Chan; Song, Sangho; Kim, Jaehwan

    2016-01-01

    This paper reports a miniaturized piezoelectric accelerometer suitable for a small haptic actuator array. The accelerometer is made with zinc oxide (ZnO) nanowire (NW) grown on a copper wafer by a hydrothermal process. The size of the accelerometer is 1.5 × 1.5 mm2, thus fitting the 1.8 × 1.8 mm2 haptic actuator array cell. The detailed fabrication process of the miniaturized accelerometer is illustrated. Performance evaluation of the fabricated accelerometer is conducted by comparing it with a commercial piezoelectric accelerometer. The output current of the fabricated accelerometer increases linearly with the acceleration. The miniaturized ZnO NW accelerometer is feasible for acceleration measurement of small and lightweight devices. PMID:27649184

  2. The Proterozoic Mount Isa Fault Zone, northeastern Australia: is it really a ca. 1.9 Ga terrane-bounding suture?

    NASA Astrophysics Data System (ADS)

    Bierlein, Frank P.; Betts, Peter G.

    2004-09-01

    In marked contrast to Palaeoproterozoic Laurentia, the location of sutures and boundaries of discrete crustal fragments amalgamated during Palaeoproterozoic formation of the North Australian Craton remain highly speculative. Interpretations of suture locations have relied heavily on the analysis of regional geophysical datasets because of sparse exposure of rocks of the appropriate age. The Mount Isa Fault Zone has been interpreted as one such Palaeoproterozoic terrane-bounding suture. Furthermore, the coincidence of this fault zone with major shale-hosted massive sulphide Pb-Zn-Ag orebodies has led to speculations that trans-lithospheric faults may be an important ingredient for the development of this deposit type. This study has integrated geophysical and geochemical data to test the statute of the Mount Isa Fault as a terrane-bounding suture. Forward modelling of gravity data shows that basement rocks on either side of the Mount Isa Fault have similar densities. These interpretations are consistent with geochemical observations and Sm-Nd data that suggest that basement lithologies on either side of the Mount Isa Fault are geochemically and isotopically indistinguishable from each other, and that the Mount Isa Fault is unlikely to represent a suture zone that separates different Palaeoproterozoic terranes. Our data indicate that the crustal blocks on both sides of the Mount Isa Fault Zone must have been in within close proximity of each other since the Palaeoproterozoic, and that the Western Fold Belt was part of the (ancestral) North Australian Craton well before the ˜1.89-1.87 Ga Barramundi Orogeny. It appears that deep crustal variations in density may be related to the boundary between a shallowly west-dipping high-density mafic to ultramafic plate and low-density basement rocks. This interpretation in turn impacts on crustal-scale models for the development of shale-hosted massive sulphide Pb-Zn mineralisation, which do not require trans-lithospheric faults to tap deep-seated metal reservoirs and/or mantle plumbing systems. The approach applied herein demonstrates the value of multi-disciplinary investigations to the critical assessment of long-lived Proterozoic fault systems which, in the absence of methodical analysis, are commonly assumed to represent terrane-bounding sutures.

  3. Air Quality Instrumentation. Volume 2.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers, the second in a series, from recent ISA symposia dealing with air pollution. Papers range from a discussion of individual pollutant measurements to…

  4. Air Quality Instrumentation. Volume 1.

    ERIC Educational Resources Information Center

    Scales, John W., Ed.

    To insure a wide dissemination of information describing advances in measurement and control techniques, the Instrument Society of America (ISA) has published this monograph of selected papers from recent ISA symposia dealing with air pollution. Papers range from a discussion of some relatively new applications of proven techniques to discussions…

  5. Integrated Science Assessment (ISA) for Carbon Monoxide (Final Report, Jan 2010)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO...

  6. Automated feedback to foster safe driving in young drivers: phase 2 : traffic tech.

    DOT National Transportation Integrated Search

    2015-12-01

    Intelligent Speed Adaptation (ISA) provides a promising approach to reduce speeding. A core principle of ISA is real-time feedback that lets drivers know when they are driving over the speed limit. The overall goal of the study was to provide insight...

  7. Integrated Science Assessment (ISA) for Particulate Matter (Final Report, Dec 2009)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Particulate Matter (PM). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to p...

  8. Analysis of isothermal and cooling-rate-dependent immersion freezing by a unifying stochastic ice nucleation model

    NASA Astrophysics Data System (ADS)

    Alpert, Peter A.; Knopf, Daniel A.

    2016-02-01

    Immersion freezing is an important ice nucleation pathway involved in the formation of cirrus and mixed-phase clouds. Laboratory immersion freezing experiments are necessary to determine the range in temperature, T, and relative humidity, RH, at which ice nucleation occurs and to quantify the associated nucleation kinetics. Typically, isothermal (applying a constant temperature) and cooling-rate-dependent immersion freezing experiments are conducted. In these experiments it is usually assumed that the droplets containing ice nucleating particles (INPs) all have the same INP surface area (ISA); however, the validity of this assumption or the impact it may have on analysis and interpretation of the experimental data is rarely questioned. Descriptions of ice active sites and variability of contact angles have been successfully formulated to describe ice nucleation experimental data in previous research; however, we consider the ability of a stochastic freezing model founded on classical nucleation theory to reproduce previous results and to explain experimental uncertainties and data scatter. A stochastic immersion freezing model based on first principles of statistics is presented, which accounts for variable ISA per droplet and uses parameters including the total number of droplets, Ntot, and the heterogeneous ice nucleation rate coefficient, Jhet(T). This model is applied to address if (i) a time and ISA-dependent stochastic immersion freezing process can explain laboratory immersion freezing data for different experimental methods and (ii) the assumption that all droplets contain identical ISA is a valid conjecture with subsequent consequences for analysis and interpretation of immersion freezing. The simple stochastic model can reproduce the observed time and surface area dependence in immersion freezing experiments for a variety of methods such as: droplets on a cold-stage exposed to air or surrounded by an oil matrix, wind and acoustically levitated droplets, droplets in a continuous-flow diffusion chamber (CFDC), the Leipzig aerosol cloud interaction simulator (LACIS), and the aerosol interaction and dynamics in the atmosphere (AIDA) cloud chamber. Observed time-dependent isothermal frozen fractions exhibiting non-exponential behavior can be readily explained by this model considering varying ISA. An apparent cooling-rate dependence of Jhet is explained by assuming identical ISA in each droplet. When accounting for ISA variability, the cooling-rate dependence of ice nucleation kinetics vanishes as expected from classical nucleation theory. The model simulations allow for a quantitative experimental uncertainty analysis for parameters Ntot, T, RH, and the ISA variability. The implications of our results for experimental analysis and interpretation of the immersion freezing process are discussed.

  9. Fe Isolated Single Atoms on S, N Codoped Carbon by Copolymer Pyrolysis Strategy for Highly Efficient Oxygen Reduction Reaction.

    PubMed

    Li, Qiheng; Chen, Wenxing; Xiao, Hai; Gong, Yue; Li, Zhi; Zheng, Lirong; Zheng, Xusheng; Yan, Wensheng; Cheong, Weng-Chon; Shen, Rongan; Fu, Ninghua; Gu, Lin; Zhuang, Zhongbin; Chen, Chen; Wang, Dingsheng; Peng, Qing; Li, Jun; Li, Yadong

    2018-06-01

    Heteroatom-doped Fe-NC catalyst has emerged as one of the most promising candidates to replace noble metal-based catalysts for highly efficient oxygen reduction reaction (ORR). However, delicate controls over their structure parameters to optimize the catalytic efficiency and molecular-level understandings of the catalytic mechanism are still challenging. Herein, a novel pyrrole-thiophene copolymer pyrolysis strategy to synthesize Fe-isolated single atoms on sulfur and nitrogen-codoped carbon (Fe-ISA/SNC) with controllable S, N doping is rationally designed. The catalytic efficiency of Fe-ISA/SNC shows a volcano-type curve with the increase of sulfur doping. The optimized Fe-ISA/SNC exhibits a half-wave potential of 0.896 V (vs reversible hydrogen electrode (RHE)), which is more positive than those of Fe-isolated single atoms on nitrogen codoped carbon (Fe-ISA/NC, 0.839 V), commercial Pt/C (0.841 V), and most reported nonprecious metal catalysts. Fe-ISA/SNC is methanol tolerable and shows negligible activity decay in alkaline condition during 15 000 voltage cycles. X-ray absorption fine structure analysis and density functional theory calculations reveal that the incorporated sulfur engineers the charges on N atoms surrounding the Fe reactive center. The enriched charge facilitates the rate-limiting reductive release of OH* and therefore improved the overall ORR efficiency. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A Review of Recent RLV Research Activities in Japan

    NASA Astrophysics Data System (ADS)

    Sasaki, Makoto; Watanabe, Atsutaro

    2004-02-01

    Researches on reusable launch vehicle (RLV) in Japan have been conducted mainly by the three space agencies: the National Space Development Agency of Japan (NASDA), the National Aerospace Laboratory of Japan (NAL) and the Institute of Space and Astronautical Science (ISAS). HOPE-X program by NASDA/NAL, spaceplane/scramjet related researches by NAL, and development studies of ATREX engine and small reusable vehicle testing (RVT) by ISAS are such major activities. After the consecutive launch failures of NASDA's H-II and ISAS's M-V rockets in 1999-2000, it was concluded that more intensive efforts should be concentrated on the reliability improvement of those major expendable vehicles and that RLV related researches should be promoted to establish fundamental technologies essential to future RLV. In past two years, NASDA succeeded in five consecutive launches of new H-IIA, and ISAS successfully resumed the launch of M-V. As for RLV researches, considerable progress has been achieved in the high speed flight demonstration (HSFD) tests of HOPE-X program, scramjet tests of Mach 4 to 8 by NAL, and ATREX engine and small RVT tests by ISAS. The current three space agencies will be merged into one in October 2003 to establish a new organization named Japan Aerospace Exploration Agency (JAXA). It is expected that the above research activities will be also merged to promote a higher-level research program on RLV.

  11. Outcomes of changing immunosuppressive therapy after treatment failure in patients with noninfectious uveitis.

    PubMed

    Joshi, Lavnish; Talat, Lazha; Yaganti, Satish; Sandhu, Sartaj; Taylor, Simon R J; Wakefield, Denis; McCluskey, Peter; Lightman, Susan

    2014-05-01

    To evaluate the outcomes of changing immunosuppressive therapy for noninfectious uveitis after failure. Retrospective cohort study. Patients with noninfectious uveitis managed at 2 tertiary uveitis clinics in the United Kingdom and Australia. Participants with a history of using immunosuppressive therapy were identified in clinics, and notes were reviewed by doctors trained in uveitis therapy. Each treatment episode/course (starting or changing a therapy) was identified, and demographic details, clinical characteristics, drug used (second-line immunosuppressive agent [ISA] or biologicals), and drug doses were obtained. For each treatment episode, the reasons for changing therapy, corticosteroid-sparing effects, and control of inflammation were determined. A total of 147 patients were identified who underwent 309 different treatment episodes. Fifty-five percent of patients eventually required a change in treatment after their first treatment episode/course. Forty-five episodes involved switching from one ISA to another, with 50% to 100% of these patients achieving "success" (prednisolone ≤10 mg and sustained control) with the new ISA. A combination of ISAs were used in 53 episodes, with "success" being achieved in 50% to 71% of these patients. Biological agents were used in 45 episodes, the most common one being infliximab, which achieved success in 80% of patients. Our data suggest that control of inflammation can be achieved after switching or combining ISAs. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. 78 FR 5238 - Request for Comments on an International Services Agreement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-24

    ... Administration's intention to enter into negotiations for an International Services Agreement (ISA) with an... to participate in negotiations with the United States to establish an ISA: Australia, Canada, Chile... Turkey. This group, which may expand as the negotiations proceed, includes a range of developed and...

  13. Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Ecological Criteria (Final Report, Dec 2008)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Ecological Criteria. This document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the ...

  14. 78 FR 27374 - Workshop To Review Initial Draft Materials for the Nitrogen Oxides (NOX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-10

    ... materials that will inform the development of the NO X Integrated Science Assessment (ISA) for health... ENVIRONMENTAL PROTECTION AGENCY [FRL-9812-6] Workshop To Review Initial Draft Materials for the Nitrogen Oxides (NO X ) Integrated Science Assessment (ISA) for Health Effects AGENCY: Environmental...

  15. 78 FR 70040 - Draft Integrated Science Assessment for Nitrogen Oxides-Health Criteria

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-22

    ... (NO 2 ). The Integrated Science Assessment (ISA), in conjunction with additional technical and policy... the secondary (welfare-based) NAAQS for NO 2 , in conjunction with a review of the secondary NAAQS for... called an Air Quality Criteria Document). The ISA, in conjunction with additional technical and policy...

  16. Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria (Final Report, Sep 2008)

    EPA Science Inventory

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria final assessment. This report represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scien...

  17. Compliance control for a hydraulic bouncing system.

    PubMed

    Chen, Guangrong; Wang, Junzheng; Wang, Shoukun; Zhao, Jiangbo; Shen, Wei

    2018-05-17

    This paper is to reduce the contact impact, control the leg stiffness and bouncing height. Firstly, the combining position/force active compliance control was involved in the deceleration phase to decrease the impact force and improve the leg compliance capacity. Then a reasonable velocity control of cylinder was addressed to control the bouncing height to the given value in the acceleration phase. Due to the model uncertainties and disturbances in the deceleration and acceleration phase, a near inverse like controller with a proportional and differential control (PD) was added into the velocity control of acceleration phase to compensate the bouncing height control error. Finally, the effectiveness of proposed controller was validated by experiments. Experimental results showed the impact force could be reduced effectively and a significant bouncing height control performance could be achieved. The influences of initial energy, preload of spring and velocity of cylinder on the bouncing height were addressed as well. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  18. Improved Signal Processing Technique Leads to More Robust Self Diagnostic Accelerometer System

    NASA Technical Reports Server (NTRS)

    Tokars, Roger; Lekki, John; Jaros, Dave; Riggs, Terrence; Evans, Kenneth P.

    2010-01-01

    The self diagnostic accelerometer (SDA) is a sensor system designed to actively monitor the health of an accelerometer. In this case an accelerometer is considered healthy if it can be determined that it is operating correctly and its measurements may be relied upon. The SDA system accomplishes this by actively monitoring the accelerometer for a variety of failure conditions including accelerometer structural damage, an electrical open circuit, and most importantly accelerometer detachment. In recent testing of the SDA system in emulated engine operating conditions it has been found that a more robust signal processing technique was necessary. An improved accelerometer diagnostic technique and test results of the SDA system utilizing this technique are presented here. Furthermore, the real time, autonomous capability of the SDA system to concurrently compensate for effects from real operating conditions such as temperature changes and mechanical noise, while monitoring the condition of the accelerometer health and attachment, will be demonstrated.

  19. Open architecture design and approach for the Integrated Sensor Architecture (ISA)

    NASA Astrophysics Data System (ADS)

    Moulton, Christine L.; Krzywicki, Alan T.; Hepp, Jared J.; Harrell, John; Kogut, Michael

    2015-05-01

    Integrated Sensor Architecture (ISA) is designed in response to stovepiped integration approaches. The design, based on the principles of Service Oriented Architectures (SOA) and Open Architectures, addresses the problem of integration, and is not designed for specific sensors or systems. The use of SOA and Open Architecture approaches has led to a flexible, extensible architecture. Using these approaches, and supported with common data formats, open protocol specifications, and Department of Defense Architecture Framework (DoDAF) system architecture documents, an integration-focused architecture has been developed. ISA can help move the Department of Defense (DoD) from costly stovepipe solutions to a more cost-effective plug-and-play design to support interoperability.

  20. 75 FR 69078 - Workshop To Review Draft Materials for the Lead (Pb) Integrated Science Assessment (ISA)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-10

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9224-7] Workshop To Review Draft Materials for the Lead (Pb) Integrated Science Assessment (ISA) AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of Workshop... (NAAQS) for Lead (Pb), EPA is announcing that a workshop to evaluate initial draft materials for the Pb...

  1. Integrated Science Assessment (ISA) for Oxides of Nitrogen ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Oxides of Nitrogen and Sulfur - Ecological Criteria. This document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA's decision on retaining or revising the current secondary standards for oxides of nitrogen (NO2 and SO2). The intent of the ISA, according to the CAA, is to “accurately reflect the latest scientific knowledge expected from the presence of [a] pollutant in ambient air” (U.S. Code, 1970a, 1970b). It includes scientific research from atmospheric sciences, exposure and deposition, biogeochemistry, hydrology, soil science, marine science, plant physiology, animal physiology, and ecology conducted at multiple scales (e.g., population, community, ecosystem, landscape levels). Key information and judgments formerly found in the Air Quality Criteria Documents (AQCDs) for NOX and SOX are included; Annexes provide a more detailed discussion of the most pertinent scientific literature. Together, the ISA and Annexes serve to update and revise the last NOX and SOX AQCDs which were published in 1993 and 1982, respectively.

  2. Integrated Science Assessment (ISA) for Particulate Matter ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Particulate Matter (PM). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to particulate matter (PM). The development of this document is part of the Agency's periodic review of the national ambient air quality standards (NAAQS) for PM. The recently completed PM ISA and supplementary annexes, in conjunction with additional technical and policy assessments developed by EPA’s Office of Air and Radiation, will provide the scientific basis to inform EPA decisions related to the review of the current PM NAAQS. Key information and judgments formerly contained in an Air Quality Criteria Document (AQCD) for PM are incorporated in this assessment. Additional details of the pertinent literature published since the last review, as well as selected older studies of particular interest, are included in a series of annexes. This ISA thus serves to update and revise the evaluation of the scientific evidence available at the time of the previous review of the NAAQS for PM that was concluded in 2006.

  3. Protective oral vaccination against infectious salmon anaemia virus in Salmo salar.

    PubMed

    Caruffo, Mario; Maturana, Carlos; Kambalapally, Swetha; Larenas, Julio; Tobar, Jaime A

    2016-07-01

    Infectious salmon anemia (ISA) is a systemic disease caused by an orthomyxovirus, which has a significant economic impact on the production of Atlantic salmon (Salmo salar). Currently, there are several commercial ISA vaccines available, however, those products are applied through injection, causing stress in the fish and leaving them susceptible to infectious diseases due to the injection process and associated handling. In this study, we evaluated an oral vaccine against ISA containing a recombinant viral hemagglutinin-esterase and a fusion protein as antigens. Our findings indicated that oral vaccination is able to protect Atlantic salmon against challenge with a high-virulence Chilean isolate. The oral vaccination was also correlated with the induction of IgM-specific antibodies. On the other hand, the vaccine was unable to modulate expression of the antiviral related gene Mx, showing the importance of the humoral response to the disease survival. This study provides new insights into fish protection and immune response induced by an oral vaccine against ISA, but also promises future development of preventive solutions or validation of the current existing therapies. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. The role of social drinking factors in the relationship between incapacitated sexual assault and drinking before sexual activity.

    PubMed

    Bird, Elizabeth R; Gilmore, Amanda K; George, William H; Lewis, Melissa A

    2016-01-01

    White House Council on Women and Girls (2014) highlighted sexual assault prevention as a high priority issue in need of immediate attention. A risk factor associated with sexual assault victimization and revictimization is drinking before sexual activity. The current study examined the relationship between incapacitated sexual assault (ISA) and drinking before sexual activity. Given the typical social context of both drinking before sexual activity and sexual assault in college settings, social-related drinking factors including drinking to conform motives, social drinking motives, and perceived drinking norms were examined. Six hundred and three undergraduate college women completed a survey online assessing history of ISA, social factors associated with drinking, and frequency of drinking before sexual activity. Path analysis indicated that both ISA before college and since entering college were associated with higher perceived drinking norms, more social drinking motive endorsement, and more drinking to conform. However, only higher perceived drinking norms and more social drinking motive endorsement were associated with both more severe ISA histories and more frequent drinking before sexual activity. Thus, a more severe ISA history was indeed associated with more frequent drinking before sexual activity and social factors related to drinking played a significant role in this relationship. Social factors can be easily targeted through brief interventions and these findings can inform future programming to promote more careful use of alcohol in social and sexual situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Induction of multispecific Th-1 type immune response against HCV in mice by protein immunization using CpG and Montanide ISA 720 as adjuvants

    PubMed Central

    Qiu, Qi; Wang, Richard Yuan-Hu; Jiao, Xuanmao; Jin, Bo; Sugauchi, Fuminaka; Grandinetti, Teresa; Alter, Harvey J.; Shih, J. Wai-Kuo

    2017-01-01

    Recent studies demonstrate that Th1-type immune responses against a broad spectrum of hepatitis C virus (HCV) gene products are crucial to the resolution of acute HCV infection. We investigated new vaccine approaches to augment the strength of HCV-specific Th1-type immune responses. ELISPOT assay revealed that single or multiple protein immunization using both CpG ODN and Montanide ISA 720 as adjuvants induced much stronger IFN-γ-producing Th1 responses against core, NS3 and NS5b targets than did the formulation without these adjuvants. Protein vaccination using CpG ODN and Montanide ISA 720 as adjuvants also greatly enhanced humoral responses to HCV core, E1/E2 and NS3. When specific IgG isotypes were assayed, protein immunization using CpG ODN and Montanide ISA 720 as adjuvants produced higher titers of IgG2a dominant antibodies than did protein immunization alone, indicating a more Th1-biasedpathway. This increase in IgG2a is consistent with the induction of Th1 cells secreting IFN-γ demonstrated by ELISPOT assay. In conclusion, protein immunization using CpG ODN and Montanide ISA 720 as adjuvants greatly enhanced cellular (Th1 type) as well as humoral immune responses against HCV in Balb/c mice. The use of adjuvants appears critical to the induction of Th1 immune responses during HCV vaccination with recombinant proteins. PMID:18675871

  6. Induction of multispecific Th-1 type immune response against HCV in mice by protein immunization using CpG and Montanide ISA 720 as adjuvants.

    PubMed

    Qiu, Qi; Wang, Richard Yuan-Hu; Jiao, Xuanmao; Jin, Bo; Sugauchi, Fuminaka; Grandinetti, Teresa; Alter, Harvey J; Shih, J Wai-Kuo

    2008-10-09

    Recent studies demonstrate that Th1-type immune responses against a broad spectrum of hepatitis C virus (HCV) gene products are crucial to the resolution of acute HCV infection. We investigated new vaccine approaches to augment the strength of HCV-specific Th1-type immune responses. ELISPOT assay revealed that single or multiple protein immunization using both CpG ODN and Montanide ISA 720 as adjuvants induced much stronger IFN-gamma-producing Th1 responses against core, NS3 and NS5b targets than did the formulation without these adjuvants. Protein vaccination using CpG ODN and Montanide ISA 720 as adjuvants also greatly enhanced humoral responses to HCV core, E1/E2 and NS3. When specific IgG isotypes were assayed, protein immunization using CpG ODN and Montanide ISA 720 as adjuvants produced higher titers of IgG2a dominant antibodies than did protein immunization alone, indicating a more Th1-biased pathway. This increase in IgG2a is consistent with the induction of Th1 cells secreting IFN-gamma demonstrated by ELISPOT assay. In conclusion, protein immunization using CpG ODN and Montanide ISA 720 as adjuvants greatly enhanced cellular (Th1 type) as well as humoral immune responses against HCV in Balb/c mice. The use of adjuvants appears critical to the induction of Th1 immune responses during HCV vaccination with recombinant proteins.

  7. Is there a correlation between the change in the interscrew angle of the eight-plate and the delta joint orientation angles?

    PubMed

    Marangoz, Salih; Buyukdogan, Kadir; Karahan, Sevilay

    2017-01-01

    It is known that the screws of the eight-plate hemiepiphysiodesis construct diverge as growth occurs through the physis. Our objective was to investigate whether there is a correlation between the amount of change of the joint orientation angle (JOA) and that of the interscrew angle (ISA) of the eight-plate hemiepiphysiodesis construct before and after correction. After the institutional review board approval, medical charts and X-rays of all patients operated for either genu valgum or genu varum with eight-plate hemiepiphysiodesis were analyzed retrospectively. All consecutive patients at various ages with miscellaneous diagnoses were included. JOA and ISA were measured before and after correction. After review of the X-rays, statistical analyses were performed which included Pearson correlation coefficient and regression analyses. There were 53 segments of 30 patients included in the study. Eighteen were males, and 12 were females. Mean age at surgery was 9.1 (range 3-17). Mean follow-up time was 21.5 (range, 7-46) months. The diagnoses were diverse. A strong correlation was found between the delta JOA (d-JOA) and delta ISA (d-ISA) of the eight-plate hemiepiphysiodesis construct (r = 0.759 (0.615-0.854, 95%CI), p < 0.001). This correlation was independent of the age and gender of the patient. There is a strong correlation between the d-ISA and the d-JOA. The d-ISA follows the d-JOA at a predictable amount through formulas which regression analysis yielded. This study confirms the clinical observation of the diverging angle between the screws is in correlation with the correction of the JOA. Level IV, Therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  8. EntrySat: A 3U CubeStat to study the reentry atmospheric environment

    NASA Astrophysics Data System (ADS)

    Anthony, Sournac; Raphael, Garcia; David, Mimoun; Jeremie, Chaix

    2016-04-01

    ISAE France Entrysat has for main scientific objective the study of uncontrolled atmospheric re-entry. This project, is developed by ISAE in collaboration with ONERA and University of Toulouse, is funded by CNES, in the overall frame of the QB50 project. This nano-satellite is a 3U Cubesat measuring 34*10*10 cm3, similar to secondary debris produced during the break up of a spacecraft. EntrySat will collect the external and internal temperatures, pressure, heat flux, attitude variations and drag force of the satellite between ≈150 and 90 km before its destruction in the atmosphere, and transmit them during the re-entry using the IRIDIUM satellite network. The result will be compared with the computations of MUSIC/FAST, a new 6-degree of freedom code developed by ONERA to predict the trajectory of space debris. In order to fulfil the scientific objectives, the satellite will acquire 18 re-entry sensors signals, convert them and compress them, thanks to an electronic board developed by ISAE students in cooperation with EREMS. In order to transmit these data every second during the re-entry phase, the satellite will use an IRIDIUM connection. In order to keep a stable enough attitudes during this phase, a simple attitude orbit and control system using magnetotorquers and an inertial measurement unit (IMU) is developed at ISAE by students. A commercial GPS board is also integrated in the satellite into Entry Sat to determine its position and velocity which are necessary during the re-entry phase. This GPS will also be used to synchronize the on-board clock with the real-time UTC data. During the orbital phase (≈2 year) EntrySat measurements will be recorded transmitted through a more classical "UHF/VHF" connection. Preference for presentation: Poster Most suitable session: Author for correspondence: Dr Raphael F. Garcia ISAE 10, ave E. Belin, 31400 Toulouse, France Raphael.GARCIA@isae.fr +33 5 61 33 81 14

  9. Understanding the Effects of Urban Expansion on Spatio-temporal Variations of Vegetation Phenology at Global Scale from 1993 to 2014

    NASA Astrophysics Data System (ADS)

    Qiu, T.; Song, C.

    2017-12-01

    Many studies have examined the urbanization-induced vegetation phenology changes in urban environments at regional scales. However, relatively few studies have investigated the effects of urban expansion on vegetation phenology at global scale. In this study, we used times series of NASA Vegetation Index and Phenology (VIP) and ESA Climate Change Initiative Land Cover datasets to quantify how urban expansion affects growing seasons of vegetation in 14 different biomes along both latitude and urbanization gradients from 1993 to 2014. First, we calculated the percentages of impervious surface area (ISA) at 0.05˚ grid to match the spatial resolution of VIP dataset. We then applied logistic models to the ISA series to characterize the time periods of stable ISA, pre-urbanization and post-urbanization for each grid. The amplitudes of urbanization were also derived from the fitted ISA series. We then calculated the mean values of the Start of Season (SOS), End of Season (EOS) and Length of Season (LOS) from VIP datasets within each period. Linear regressions were used to quantify the correlations between ISA and SOS/EOS/LOS in 14 biomes along the latitude gradient for each period. We also calculated the differences of SOS/EOS/LOS between pre-urbanization and post-urbanization periods and applied quantile regressions to characterize the relationships between amplitudes of urbanization and those differences. We found significant correlations (p-value < 0.05) between ISA and the growing seasons of a) boreal forests at 55-60 ˚N; b) temperate broadleaf and mixed forests at 30-55 ˚N; c) temperate coniferous forests at 30-45 ˚N; d) temperate grasslands, savannas, and shrublands at 35-60 ˚N and 30-35 ˚S. We also found a significant positive correlation (p-value <0.05) between amplitudes of urbanization and LOS as well as a significant negative correlation (p-value<0.05) between amplitudes of urbanization and SOS in temperate broadleaf and mixed forest.

  10. The Influence of Endmember Selection Method in Extracting Impervious Surface from Airborne Hyperspectral Imagery

    NASA Astrophysics Data System (ADS)

    Wang, J.; Feng, B.

    2016-12-01

    Impervious surface area (ISA) has long been studied as an important input into moisture flux models. In general, ISA impedes groundwater recharge, increases stormflow/flood frequency, and alters in-stream and riparian habitats. Urban area is recognized as one of the richest ISA environment. Urban ISA mapping assists flood prevention and urban planning. Hyperspectral imagery (HI), for its ability to detect subtle spectral signature, becomes an ideal candidate in urban ISA mapping. To map ISA from HI involves endmember (EM) selection. The high degree of spatial and spectral heterogeneity of urban environment puts great difficulty in this task: a compromise point is needed between the automatic degree and the good representativeness of the method. The study tested one manual and two semi-automatic EM selection strategies. The manual and the first semi-automatic methods have been widely used in EM selection. The second semi-automatic EM selection method is rather new and has been only proposed for moderate spatial resolution satellite. The manual method visually selected the EM candidates from eight landcover types in the original image. The first semi-automatic method chose the EM candidates using a threshold over the pixel purity index (PPI) map. The second semi-automatic method used the triangle shape of the HI scatter plot in the n-Dimension visualizer to identify the V-I-S (vegetation-impervious surface-soil) EM candidates: the pixels locate at the triangle points. The initial EM candidates from the three methods were further refined by three indexes (EM average RMSE, minimum average spectral angle, and count based EM selection) and generated three spectral libraries, which were used to classify the test image. Spectral angle mapper was applied. The accuracy reports for the classification results were generated. The overall accuracy are 85% for the manual method, 81% for the PPI method, and 87% for the V-I-S method. The V-I-S EM selection method performs best in this study. This fact proves the value of V-I-S EM selection method in not only moderate spatial resolution satellite image but also the more and more accessible high spatial resolution airborne image. This semi-automatic EM selection method can be adopted into a wide range of remote sensing images and provide ISA map for hydrology analysis.

  11. Analysis of isothermal and cooling-rate-dependent immersion freezing by a unifying stochastic ice nucleation model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpert, Peter A.; Knopf, Daniel A.

    Immersion freezing is an important ice nucleation pathway involved in the formation of cirrus and mixed-phase clouds. Laboratory immersion freezing experiments are necessary to determine the range in temperature, T, and relative humidity, RH, at which ice nucleation occurs and to quantify the associated nucleation kinetics. Typically, isothermal (applying a constant temperature) and cooling-rate-dependent immersion freezing experiments are conducted. In these experiments it is usually assumed that the droplets containing ice nucleating particles (INPs) all have the same INP surface area (ISA); however, the validity of this assumption or the impact it may have on analysis and interpretation of the experimentalmore » data is rarely questioned. Descriptions of ice active sites and variability of contact angles have been successfully formulated to describe ice nucleation experimental data in previous research; however, we consider the ability of a stochastic freezing model founded on classical nucleation theory to reproduce previous results and to explain experimental uncertainties and data scatter. A stochastic immersion freezing model based on first principles of statistics is presented, which accounts for variable ISA per droplet and uses parameters including the total number of droplets, N tot, and the heterogeneous ice nucleation rate coefficient, J het( T). This model is applied to address if (i) a time and ISA-dependent stochastic immersion freezing process can explain laboratory immersion freezing data for different experimental methods and (ii) the assumption that all droplets contain identical ISA is a valid conjecture with subsequent consequences for analysis and interpretation of immersion freezing. The simple stochastic model can reproduce the observed time and surface area dependence in immersion freezing experiments for a variety of methods such as: droplets on a cold-stage exposed to air or surrounded by an oil matrix, wind and acoustically levitated droplets, droplets in a continuous-flow diffusion chamber (CFDC), the Leipzig aerosol cloud interaction simulator (LACIS), and the aerosol interaction and dynamics in the atmosphere (AIDA) cloud chamber. Observed time-dependent isothermal frozen fractions exhibiting non-exponential behavior can be readily explained by this model considering varying ISA. An apparent cooling-rate dependence of J het is explained by assuming identical ISA in each droplet. When accounting for ISA variability, the cooling-rate dependence of ice nucleation kinetics vanishes as expected from classical nucleation theory. Finally, the model simulations allow for a quantitative experimental uncertainty analysis for parameters N tot, T, RH, and the ISA variability. We discuss the implications of our results for experimental analysis and interpretation of the immersion freezing process.« less

  12. Analysis of isothermal and cooling-rate-dependent immersion freezing by a unifying stochastic ice nucleation model

    DOE PAGES

    Alpert, Peter A.; Knopf, Daniel A.

    2016-02-24

    Immersion freezing is an important ice nucleation pathway involved in the formation of cirrus and mixed-phase clouds. Laboratory immersion freezing experiments are necessary to determine the range in temperature, T, and relative humidity, RH, at which ice nucleation occurs and to quantify the associated nucleation kinetics. Typically, isothermal (applying a constant temperature) and cooling-rate-dependent immersion freezing experiments are conducted. In these experiments it is usually assumed that the droplets containing ice nucleating particles (INPs) all have the same INP surface area (ISA); however, the validity of this assumption or the impact it may have on analysis and interpretation of the experimentalmore » data is rarely questioned. Descriptions of ice active sites and variability of contact angles have been successfully formulated to describe ice nucleation experimental data in previous research; however, we consider the ability of a stochastic freezing model founded on classical nucleation theory to reproduce previous results and to explain experimental uncertainties and data scatter. A stochastic immersion freezing model based on first principles of statistics is presented, which accounts for variable ISA per droplet and uses parameters including the total number of droplets, N tot, and the heterogeneous ice nucleation rate coefficient, J het( T). This model is applied to address if (i) a time and ISA-dependent stochastic immersion freezing process can explain laboratory immersion freezing data for different experimental methods and (ii) the assumption that all droplets contain identical ISA is a valid conjecture with subsequent consequences for analysis and interpretation of immersion freezing. The simple stochastic model can reproduce the observed time and surface area dependence in immersion freezing experiments for a variety of methods such as: droplets on a cold-stage exposed to air or surrounded by an oil matrix, wind and acoustically levitated droplets, droplets in a continuous-flow diffusion chamber (CFDC), the Leipzig aerosol cloud interaction simulator (LACIS), and the aerosol interaction and dynamics in the atmosphere (AIDA) cloud chamber. Observed time-dependent isothermal frozen fractions exhibiting non-exponential behavior can be readily explained by this model considering varying ISA. An apparent cooling-rate dependence of J het is explained by assuming identical ISA in each droplet. When accounting for ISA variability, the cooling-rate dependence of ice nucleation kinetics vanishes as expected from classical nucleation theory. Finally, the model simulations allow for a quantitative experimental uncertainty analysis for parameters N tot, T, RH, and the ISA variability. We discuss the implications of our results for experimental analysis and interpretation of the immersion freezing process.« less

  13. Miniaturized accelerometer made with ZnO nanowires

    NASA Astrophysics Data System (ADS)

    Song, Sangho; Kim, Jeong Woong; Kim, Hyun Chan; Yun, Youngmin; Kim, Jaehwan

    2017-04-01

    Miniaturized accelerometer is required in many applications, such as, robotics, haptic devices, gyroscopes, simulators and mobile devices. ZnO is an essential semiconductor material with wide direct band gap, thermal stability and piezoelectricity. Especially, well aligned ZnO nanowire is appropriate for piezoelectric applications since it can produce high electrical signal under mechanical load. To miniaturize accelerometer, an aligned ZnO nanowire is adopted to implement active piezoelectric layer of the accelerometer and copper is chosen for the head mass. To grow ZnO nanowire on the copper head mass, hydrothermal synthesis is conducted and the effect of ZnO nanowire length on the accelerometer performance is investigated. Refresh hydrothermal synthesis can increase the length of ZnO nanowire. The performance of the fabricated ZnO accelerometers is compared with a commercial accelerometer. Sensitivity and linearity of the fabricated accelerometers are investigated.

  14. Changing Roles of the United States and Japan in the Security of Southeast Asia

    DTIC Science & Technology

    1994-03-01

    Mahatir Mohamad invoked the Internal Security Act (ISA) in 1981, which enabled him to detain his opponents without trial. He applied the ISA liberally and...since World War II, the reaction of Southeast Asian leaders was positive. Prime Minister Mahatir of Malaysia had "no problems whatsoever" with the

  15. Searching for the Best Deal: How Students and Their Parents View Income Share Agreements

    ERIC Educational Resources Information Center

    American Institutes for Research, 2016

    2016-01-01

    For high school students and their parents, paying for college can be daunting, particularly if student loans are a factor. Some advocates have suggested that income share agreements (ISAs) may help these families finance postsecondary education. ISAs are an alternative form of financial aid in which students pledge a portion of their future…

  16. 77 FR 52048 - Announcement of Test Providing Centralized Decision-Making Authority for Four CBP Centers of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ...-Trade Partnership Against Terrorism (C-TPAT) and Importer Self-Assessment (ISA) members in the...: Determinations, notifications, and processing concerning duty refund claims based on 19 U.S.C. 1520(d) (see 19... the test. All C-TPAT and ISA members currently participating in the existing CEEs will also need to...

  17. Integrated Science Assessment (ISA) for Oxides of Nitrogen, Oxides of Sulfur and Particulate Matter Ecological Criteria (Second External Review Draft)

    EPA Science Inventory

    This draft Integrated Science Assessment (ISA) represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision on retaining or revising the current secondary standards for NO2, SO

  18. Documentation of the ISA Micro Computed Tomography System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, William D.; Smith, Jerel A.

    2013-12-18

    This document is intended to provide information on the ISA Micro Computed Tomography (MicroCT) system that will be installed in Yavne, Israel. X-ray source, detector, and motion control hardware are specified as well as specimen platforms, containers, and reference material types. Most of the details on the system are derived from Reference 1 and 2.

  19. Performance improvement of miniaturized ZnO nanowire accelerometer fabricated by refresh hydrothermal synthesis

    PubMed Central

    Song, Sangho; Kim, Hyun Chan; Kim, Jung Woong; Kim, Debora

    2017-01-01

    Miniaturized accelerometers are necessary for evaluating the performance of small devices, such as haptics, robotics and simulators. In this study, we fabricated miniaturized accelerometers using well-aligned ZnO nanowires. The layer of ZnO nanowires is used for active piezoelectric layer of the accelerometer, and copper was chosen as a head mass. Seedless and refresh hydrothermal synthesis methods were conducted to grow ZnO nanowires on the copper substrate and the effect of ZnO nanowire length on the accelerometer performance was investigated. The refresh hydrothermal synthesis exhibits longer ZnO nanowires, 12 µm, than the seedless hydrothermal synthesis, 6 µm. Performance of the fabricated accelerometers was verified by comparing with a commercial accelerometer. The sensitivity of the fabricated accelerometer by the refresh hydrothermal synthesis is shown to be 37.7 pA g−1, which is about 30 times larger than the previous result. PMID:28989760

  20. A Model of Gravity Vector Measurement Noise for Estimating Accelerometer Bias in Gravity Disturbance Compensation.

    PubMed

    Tie, Junbo; Cao, Juliang; Chang, Lubing; Cai, Shaokun; Wu, Meiping; Lian, Junxiang

    2018-03-16

    Compensation of gravity disturbance can improve the precision of inertial navigation, but the effect of compensation will decrease due to the accelerometer bias, and estimation of the accelerometer bias is a crucial issue in gravity disturbance compensation. This paper first investigates the effect of accelerometer bias on gravity disturbance compensation, and the situation in which the accelerometer bias should be estimated is established. The accelerometer bias is estimated from the gravity vector measurement, and a model of measurement noise in gravity vector measurement is built. Based on this model, accelerometer bias is separated from the gravity vector measurement error by the method of least squares. Horizontal gravity disturbances are calculated through EGM2008 spherical harmonic model to build the simulation scene, and the simulation results indicate that precise estimations of the accelerometer bias can be obtained with the proposed method.

  1. A Model of Gravity Vector Measurement Noise for Estimating Accelerometer Bias in Gravity Disturbance Compensation

    PubMed Central

    Cao, Juliang; Cai, Shaokun; Wu, Meiping; Lian, Junxiang

    2018-01-01

    Compensation of gravity disturbance can improve the precision of inertial navigation, but the effect of compensation will decrease due to the accelerometer bias, and estimation of the accelerometer bias is a crucial issue in gravity disturbance compensation. This paper first investigates the effect of accelerometer bias on gravity disturbance compensation, and the situation in which the accelerometer bias should be estimated is established. The accelerometer bias is estimated from the gravity vector measurement, and a model of measurement noise in gravity vector measurement is built. Based on this model, accelerometer bias is separated from the gravity vector measurement error by the method of least squares. Horizontal gravity disturbances are calculated through EGM2008 spherical harmonic model to build the simulation scene, and the simulation results indicate that precise estimations of the accelerometer bias can be obtained with the proposed method. PMID:29547552

  2. Auto-Calibration and Fault Detection and Isolation of Skewed Redundant Accelerometers in Measurement While Drilling Systems.

    PubMed

    Seyed Moosavi, Seyed Mohsen; Moaveni, Bijan; Moshiri, Behzad; Arvan, Mohammad Reza

    2018-02-27

    The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors.

  3. Auto-Calibration and Fault Detection and Isolation of Skewed Redundant Accelerometers in Measurement While Drilling Systems

    PubMed Central

    Seyed Moosavi, Seyed Mohsen; Moshiri, Behzad; Arvan, Mohammad Reza

    2018-01-01

    The present study designed skewed redundant accelerometers for a Measurement While Drilling (MWD) tool and executed auto-calibration, fault diagnosis and isolation of accelerometers in this tool. The optimal structure includes four accelerometers was selected and designed precisely in accordance with the physical shape of the existing MWD tool. A new four-accelerometer structure was designed, implemented and installed on the current system, replacing the conventional orthogonal structure. Auto-calibration operation of skewed redundant accelerometers and all combinations of three accelerometers have been done. Consequently, biases, scale factors, and misalignment factors of accelerometers have been successfully estimated. By defecting the sensors in the new optimal skewed redundant structure, the fault was detected using the proposed FDI method and the faulty sensor was diagnosed and isolated. The results indicate that the system can continue to operate with at least three correct sensors. PMID:29495434

  4. Inverting Comet Acoustic Surface Sounding Experiment (CASSE) touchdown signals to measure the elastic modulus of comet material

    NASA Astrophysics Data System (ADS)

    Arnold, W.; Faber, C.; Knapmeyer, M.; Witte, L.; Schröder, S.; Tune, J.; Möhlmann, D.; Roll, R.; Chares, B.; Fischer, H.; Seidensticker, K.

    2014-07-01

    The landing of Philae on comet 67P/Churyumov-Gerasimenko is scheduled for November 11, 2014. Each of the three landing feet of Philae house a triaxial acceleration sensor of CASSE, which will thus be the first sensors to be in mechanical contact with the cometary surface. CASSE will be in listening mode to record the deceleration of the lander, when it impacts with the comet at a velocity of approx. 0.5 m/s. The analysis of this data yields information on the reduced elastic modulus and the yield stress of the comet's surface material. We describe a series of controlled landings of a lander model. The tests were conducted in the Landing & Mobility Test Facility (LAMA) of the DLR Institute of Space Systems in Bremen, Germany, where an industrial robot can be programmed to move landers or rovers along predefined paths, allowing to adapt landing procedures with predefined velocities. The qualification model of the Philae landing gear was used in the tests. It consists of three legs manufactured of carbon fiber and metal joints. A dead mass of the size and mass of the lander housing is attached via a damper above the landing gear to represent the lander structure as a whole. Attached to each leg is a foot with two soles and a mechanically driven fixation screw (''ice screw'') to secure the lander on the comet. The right soles, if viewed from the outside towards the lander body, house a Brüel & Kjaer DeltaTron 4506 triaxial piezoelectric accelerometer as used on the spacecraft. Orientation of the three axes was such that one of the axes, here the X-axis of the accelerometer, points downwards, while the Y- and Z-axes are horizontal. Data were recorded at a sampling rate of 8.2 kHz within a time gate of 2 s. In parallel, a video sequence was taken, in order to monitor the touchdown on the sand and the movement of the ice screws. Touchdown measurements were conducted on three types of ground with landing velocities between 0.1 to 1.1 m/s. Landings with low velocities were carried out on the concrete floor of the LAMA to determine the stiffness of the landing gear based on the deceleration data measured with the accelerometer. Landings on fine-grained quartz sand and on a Mars soil simulant (brand names WF34 and MSS-D, respectively) allow quantifying the changes of the deceleration data due to interaction with the soil. The elastic moduli of the soils that were inverted from the accelerometer data agree well with data obtained by ultrasonic time-of-flight measurements, provided an effective contact area is used. To this end, the lander structure was viewed in a simplified way as a mass-spring-damper system coupled to the soil by a contact spring, whose stiffness is determined by elastic moduli of the soil and the contact radius. Analytical expressions allow a rapid inversion of the deceleration data to obtain elastic data. It is expected that the same procedure can be applied to the signal measured when landing on comet 67P.

  5. The second Lilly Prize Lecture, University of Newcastle, July 1977. beta-Adrenergic receptor blockade in hypertension, past, present and future.

    PubMed Central

    Prichard, B N

    1978-01-01

    All beta-adrenoceptor blocking drugs that have been described share the common property of being competitive inhibitors. They differ in their associated properties, the presence or absence of cardioselectivity, membrane stabilizing activity, and partial agonist activity. Recently some beta-adrenoceptor blocking drugs have been reported which also possess alpha-adrenoceptor blocking activity. The associated properties have been used as a basis for classifying beta-adrenoceptor blocking drugs (Fitzgerald, 1969, 1972). The presence or absence of cardioselectivity is most useful for dividing beta-adrenoceptor blocking drugs. The non-selective drugs (Division I) can be further divided according to the presence or absence of intrinsic sympathomimetic activity (ISA) and membrane stabilizing activity (Fitzgerald's groups I-IV). Group I possess both membrane activity and ISA, e.g. alprenolol, oxprenolol, group II just membrane action, e.g. propanolol, group III ISA but no membrane action, e.g. pindolol. Fitzgerald placed pindolol in group I but should be placed in group III as it possesses a high degree of beta-adrenoceptor blocking potency in relation to its membrane activity (Prichard, 1974). Finally drugs in group IV have neither ISA nor membrane action, e.g. sotalol, timolol. The cardioselective drugs (Division II) can be similarly sub-divided into groups I-IV according to the presence or absence of ISA or membrane action (Fitzgerald grouped all these together as group V). Lastly there are new beta-adrenergic receptor blocking drugs which in addition have alpha- adrenergic receptor blocking properties (Division III). PMID:26370

  6. Design and implementation of a micromechanical silicon resonant accelerometer.

    PubMed

    Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing

    2013-11-19

    The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C.

  7. The location of the tibial accelerometer does influence impact acceleration parameters during running.

    PubMed

    Lucas-Cuevas, Angel Gabriel; Encarnación-Martínez, Alberto; Camacho-García, Andrés; Llana-Belloch, Salvador; Pérez-Soriano, Pedro

    2017-09-01

    Tibial accelerations have been associated with a number of running injuries. However, studies attaching the tibial accelerometer on the proximal section are as numerous as those attaching the accelerometer on the distal section. This study aimed to investigate whether accelerometer location influences acceleration parameters commonly reported in running literature. To fulfil this purpose, 30 athletes ran at 2.22, 2.78 and 3.33 m · s -1 with three accelerometers attached with double-sided tape and tightened to the participants' tolerance on the forehead, the proximal section of the tibia and the distal section of the tibia. Time-domain (peak acceleration, shock attenuation) and frequency-domain parameters (peak frequency, peak power, signal magnitude and shock attenuation in both the low and high frequency ranges) were calculated for each of the tibial locations. The distal accelerometer registered greater tibial acceleration peak and shock attenuation compared to the proximal accelerometer. With respect to the frequency-domain analysis, the distal accelerometer provided greater values of all the low-frequency parameters, whereas no difference was observed for the high-frequency parameters. These findings suggest that the location of the tibial accelerometer does influence the acceleration signal parameters, and thus, researchers should carefully consider the location they choose to place the accelerometer so that equivalent comparisons across studies can be made.

  8. 77 FR 5387 - Amendment to the Export Administration Regulations: Addition of a Reference to a Provision of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-03

    ... Provision of the Iran Sanctions Act of 1996 (ISA) and Statement of the Licensing Policy for Transactions... Administration Regulations (EAR) to add a reference to the Iran Sanctions Act of 1996 (ISA), which states BIS's... . SUPPLEMENTARY INFORMATION: Background Basis of Amendment The Iran Sanctions Act of 1996 (50 U.S.C. 1701 note...

  9. The Assessment of Intimate Partner Violence in Spanish Women: The Index of Spouse Abuse

    ERIC Educational Resources Information Center

    Plazaola-Castano, Juncal; Ruiz-Perez, Isabel; Escriba-Aguir, Vicenta; Montero-Pinar, Isabel; Vives-Cases, Carmen

    2011-01-01

    We aimed to analyze the internal consistency and construct validity of the Spanish version of the Index of Spouse Abuse (ISA) in a representative sample of 8,995 women attending general practice in Spain in 2006-2007. The factor structure analysis shows that the ISA measures four intimate partner violence (IPV) dimensions: emotional, physical, and…

  10. 3 CFR 13574 - Executive Order 13574 of May 23, 2011. Authorizing the Implementation of Certain Sanctions Set...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... America, including the International Emergency Economic Powers Act (50 U.S.C. 1701 et seq.) (IEEPA), the... 12957 of March 15, 1995, I, BARACK OBAMA, President of the United States of America, hereby order... in which the ISA-sanctioned person has any interest; (iii) with respect to section 6(a)(7) of ISA...

  11. Additional Support for the Information Systems Analyst Exam as a Valid Program Assessment Tool

    ERIC Educational Resources Information Center

    Carpenter, Donald A.; Snyder, Johnny; Slauson, Gayla Jo; Bridge, Morgan K.

    2011-01-01

    This paper presents a statistical analysis to support the notion that the Information Systems Analyst (ISA) exam can be used as a program assessment tool in addition to measuring student performance. It compares ISA exam scores earned by students in one particular Computer Information Systems program with scores earned by the same students on the…

  12. Integrated Science Assessment (ISA) for Carbon Monoxide ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Carbon Monoxide (CO). This report is EPA’s latest evaluation of the scientific literature on the potential human health and welfare effects associated with ambient exposures to CO. The development of this document is part of the Agency's periodic review of the national ambient air quality standards (NAAQS) for CO. The recently completed CO ISA and supplementary annexes, in conjunction with additional technical and policy assessments developed by EPA’s Office of Air and Radiation, will provide the scientific basis to inform EPA decisions related to the review of the current CO NAAQS. The integrated Plan for Review of the National Ambient Air Quality Standards for Carbon Monoxide (U.S. EPA, 2008, 193995) identifies key policy-relevant questions that provide a framework for this assessment of the scientific evidence. These questions frame the entire review of the NAAQS for CO and thus are informed by both science and policy considerations. The ISA organizes, presents, and integrates the scientific evidence which is considered along with findings from risk analyses and policy considerations to help the U.S. Environmental Protection Agency (EPA) address these questions during the NAAQS review.

  13. Analyzing human errors in flight mission operations

    NASA Technical Reports Server (NTRS)

    Bruno, Kristin J.; Welz, Linda L.; Barnes, G. Michael; Sherif, Josef

    1993-01-01

    A long-term program is in progress at JPL to reduce cost and risk of flight mission operations through a defect prevention/error management program. The main thrust of this program is to create an environment in which the performance of the total system, both the human operator and the computer system, is optimized. To this end, 1580 Incident Surprise Anomaly reports (ISA's) from 1977-1991 were analyzed from the Voyager and Magellan projects. A Pareto analysis revealed that 38 percent of the errors were classified as human errors. A preliminary cluster analysis based on the Magellan human errors (204 ISA's) is presented here. The resulting clusters described the underlying relationships among the ISA's. Initial models of human error in flight mission operations are presented. Next, the Voyager ISA's will be scored and included in the analysis. Eventually, these relationships will be used to derive a theoretically motivated and empirically validated model of human error in flight mission operations. Ultimately, this analysis will be used to make continuous process improvements continuous process improvements to end-user applications and training requirements. This Total Quality Management approach will enable the management and prevention of errors in the future.

  14. Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee Pro

    NASA Technical Reports Server (NTRS)

    Wagner, Raymond S.; Barton, Richard J.

    2011-01-01

    Standards-based wireless sensor network (WSN) protocols are promising candidates for spacecraft avionics systems, offering unprecedented instrumentation flexibility and expandability. Ensuring reliable data transport is key, however, when migrating from wired to wireless data gathering systems. In this paper, we conduct a rigorous laboratory analysis of the relative performances of the ZigBee Pro and ISA100.11a protocols in a representative crewed aerospace environment. Since both operate in the 2.4 GHz radio frequency (RF) band shared by systems such as Wi-Fi, they are subject at times to potentially debilitating RF interference. We compare goodput (application-level throughput) achievable by both under varying levels of 802.11g Wi-Fi traffic. We conclude that while the simpler, more inexpensive ZigBee Pro protocol performs well under moderate levels of interference, the more complex and costly ISA100.11a protocol is needed to ensure reliable data delivery under heavier interference. This paper represents the first published, rigorous analysis of WSN protocols in an aerospace environment that we are aware of and the first published head-to-head comparison of ZigBee Pro and ISA100.11a.

  15. Infectious salmon anaemia virus (ISAV) isolated from the ISA disease outbreaks in Chile diverged from ISAV isolates from Norway around 1996 and was disseminated around 2005, based on surface glycoprotein gene sequences.

    PubMed

    Kibenge, Frederick S B; Godoy, Marcos G; Wang, Yingwei; Kibenge, Molly J T; Gherardelli, Valentina; Mansilla, Soledad; Lisperger, Angelica; Jarpa, Miguel; Larroquete, Geraldine; Avendaño, Fernando; Lara, Marcela; Gallardo, Alicia

    2009-06-26

    Infectious salmon anaemia (ISA) virus (ISAV) is a pathogen of marine-farmed Atlantic salmon (Salmo salar); a disease first diagnosed in Norway in 1984. For over 25 years ISAV has caused major disease outbreaks in the Northern hemisphere, and remains an emerging fish pathogen because of the asymptomatic infections in marine wild fish and the potential for emergence of new epidemic strains. ISAV belongs to the family Orthomyxoviridae, together with influenza viruses but is sufficiently different to be assigned to its own genus, Isavirus. The Isavirus genome consists of eight single-stranded RNA species, and the virions have two surface glycoproteins; fusion (F) protein encoded on segment 5 and haemagglutinin-esterase (HE) protein encoded on segment 6. However, comparison between different ISAV isolates is complicated because there is presently no universally accepted nomenclature system for designation of genetic relatedness between ISAV isolates. The first outbreak of ISA in marine-farmed Atlantic salmon in the Southern hemisphere occurred in Chile starting in June 2007. In order to describe the molecular characteristics of the virus so as to understand its origins, how ISAV isolates are maintained and spread, and their virulence characteristics, we conducted a study where the viral sequences were directly amplified, cloned and sequenced from tissue samples collected from several ISA-affected fish on the different fish farms with confirmed or suspected ISA outbreaks in Chile. This paper describes the genetic characterization of a large number of ISAV strains associated with extensive outbreaks in Chile starting in June 2007, and their phylogenetic relationships with selected European and North American isolates that are representative of the genetic diversity of ISAV. RT-PCR for ISAV F and HE glycoprotein genes was performed directly on tissue samples collected from ISA-affected fish on different farms among 14 fish companies in Chile during the ISA outbreaks that started in June 2007. The genes of the F and HE glycoproteins were cloned and sequenced for 51 and 78 new isolates, respectively. An extensive comparative analysis of ISAV F and HE sequence data, including reference isolates sampled from Norway, Faroe Islands, Scotland, USA, and Canada was performed. Based on phylogenetic analysis of concatenated ISAV F and HE genes of 103 individual isolates, the isolates from the ISA outbreaks in Chile grouped in their own cluster of 7 distinct strains within Genotype I (European genotype) of ISAV, with the closest relatedness to Norwegian ISAVs isolated in 1997. The phylogenetic software program, BACKTRACK, estimated the Chile isolates diverged from Norway isolates about 1996 and, therefore, had been present in Chile for some time before the recent outbreaks. Analysis of the deduced F protein sequence showed 43 of 51 Chile isolates with an 11-amino acid insert between 265N and 266Q, with 100% sequence identity with Genotype I ISAV RNA segment 2. Twenty four different HE-HPRs, including HPR0, were detected, with HPR7b making up 79.7%. This is considered a manifestation of ISAV quasispecies HE protein sequence diversity. Taken together, these findings suggest that the ISA outbreaks were caused by virus that was already present in Chile that mutated to new strains. This is the first comprehensive report tracing ISAV from Europe to South America.

  16. Infectious salmon anaemia virus (ISAV) isolated from the ISA disease outbreaks in Chile diverged from ISAV isolates from Norway around 1996 and was disseminated around 2005, based on surface glycoprotein gene sequences

    PubMed Central

    Kibenge, Frederick SB; Godoy, Marcos G; Wang, Yingwei; Kibenge, Molly JT; Gherardelli, Valentina; Mansilla, Soledad; Lisperger, Angelica; Jarpa, Miguel; Larroquete, Geraldine; Avendaño, Fernando; Lara, Marcela; Gallardo, Alicia

    2009-01-01

    Background Infectious salmon anaemia (ISA) virus (ISAV) is a pathogen of marine-farmed Atlantic salmon (Salmo salar); a disease first diagnosed in Norway in 1984. For over 25 years ISAV has caused major disease outbreaks in the Northern hemisphere, and remains an emerging fish pathogen because of the asymptomatic infections in marine wild fish and the potential for emergence of new epidemic strains. ISAV belongs to the family Orthomyxoviridae, together with influenza viruses but is sufficiently different to be assigned to its own genus, Isavirus. The Isavirus genome consists of eight single-stranded RNA species, and the virions have two surface glycoproteins; fusion (F) protein encoded on segment 5 and haemagglutinin-esterase (HE) protein encoded on segment 6. However, comparision between different ISAV isolates is complicated because there is presently no universally accepted nomenclature system for designation of genetic relatedness between ISAV isolates. The first outbreak of ISA in marine-farmed Atlantic salmon in the Southern hemisphere occurred in Chile starting in June 2007. In order to describe the molecular characteristics of the virus so as to understand its origins, how ISAV isolates are maintained and spread, and their virulence characteristics, we conducted a study where the viral sequences were directly amplified, cloned and sequenced from tissue samples collected from several ISA-affected fish on the different fish farms with confirmed or suspected ISA outbreaks in Chile. This paper describes the genetic characterization of a large number of ISAV strains associated with extensive outbreaks in Chile starting in June 2007, and their phylogenetic relationships with selected European and North American isolates that are representative of the genetic diversity of ISAV. Results RT-PCR for ISAV F and HE glycoprotein genes was performed directly on tissue samples collected from ISA-affected fish on different farms among 14 fish companies in Chile during the ISA outbreaks that started in June 2007. The genes of the F and HE glycoproteins were cloned and sequenced for 51 and 78 new isolates, respectively. An extensive comparative analysis of ISAV F and HE sequence data, including reference isolates sampled from Norway, Faroe Islands, Scotland, USA, and Canada was performed. Based on phylogenetic analysis of concatenated ISAV F and HE genes of 103 individual isolates, the isolates from the ISA outbreaks in Chile grouped in their own cluster of 7 distinct strains within Genotype I (European genotype) of ISAV, with the closest relatedness to Norwegian ISAVs isolated in 1997. The phylogenetic software program, BACKTRACK, estimated the Chile isolates diverged from Norway isolates about 1996 and, therefore, had been present in Chile for some time before the recent outbreaks. Analysis of the deduced F protein sequence showed 43 of 51 Chile isolates with an 11-amino acid insert between 265N and 266Q, with 100% sequence identity with Genotype I ISAV RNA segment 2. Twenty four different HE-HPRs, including HPR0, were detected, with HPR7b making up 79.7%. This is considered a manifestation of ISAV quasispecies HE protein sequence diversity. Conclusion Taken together, these findings suggest that the ISA outbreaks were caused by virus that was already present in Chile that mutated to new strains. This is the first comprehensive report tracing ISAV from Europe to South America. PMID:19558648

  17. Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior.

    PubMed

    Montoye, Alexander H K; Pivarnik, James M; Mudd, Lanay M; Biswas, Subir; Pfeiffer, Karin A

    2016-01-01

    Recent evidence suggests that physical activity (PA) and sedentary behavior (SB) exert independent effects on health. Therefore, measurement methods that can accurately assess both constructs are needed. To compare the accuracy of accelerometers placed on the hip, thigh, and wrists, coupled with machine learning models, for measurement of PA intensity category (SB, light-intensity PA [LPA], and moderate- to vigorous-intensity PA [MVPA]) and breaks in SB. Forty young adults (21 female; age 22.0 ± 4.2 years) participated in a 90-minute semi-structured protocol, performing 13 activities (three sedentary, 10 non-sedentary) for 3-10 minutes each. Participants chose activity order, duration, and intensity. Direct observation (DO) was used as a criterion measure of PA intensity category, and transitions from SB to a non-sedentary activity were breaks in SB. Participants wore four accelerometers (right hip, right thigh, and both wrists), and a machine learning model was created for each accelerometer to predict PA intensity category. Sensitivity and specificity for PA intensity category classification were calculated and compared across accelerometers using repeated measures analysis of variance, and the number of breaks in SB was compared using repeated measures analysis of variance. Sensitivity and specificity values for the thigh-worn accelerometer were higher than for wrist- or hip-worn accelerometers, > 99% for all PA intensity categories. Sensitivity and specificity for the hip-worn accelerometer were 87-95% and 93-97%. The left wrist-worn accelerometer had sensitivities and specificities of > 97% for SB and LPA and 91-95% for MVPA, whereas the right wrist-worn accelerometer had sensitivities and specificities of 93-99% for SB and LPA but 67-84% for MVPA. The thigh-worn accelerometer had high accuracy for breaks in SB; all other accelerometers overestimated breaks in SB. Coupled with machine learning modeling, the thigh-worn accelerometer should be considered when objectively assessing PA and SB.

  18. Compact Circuit Preprocesses Accelerometer Output

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1993-01-01

    Compact electronic circuit transfers dc power to, and preprocesses ac output of, accelerometer and associated preamplifier. Incorporated into accelerometer case during initial fabrication or retrofit onto commercial accelerometer. Made of commercial integrated circuits and other conventional components; made smaller by use of micrologic and surface-mount technology.

  19. Tool enables proper mating of accelerometer and cable connector

    NASA Technical Reports Server (NTRS)

    Steed, C. N.

    1966-01-01

    Tool supports accelerometer in axial alignment with an accelerometer cable connector and permits tightening of the accelerometer to the cable connector with a torque wrench. This is done without damaging the components or permitting them to work loose under sustained, high-level vibrations.

  20. Self-noise models of five commercial strong-motion accelerometers

    USGS Publications Warehouse

    Ringler, Adam; Evans, John R.; Hutt, Charles R.

    2015-01-01

    To better characterize the noise of a number of commonly deployed accelerometers in a standardized way, we conducted noise measurements on five different models of strong‐motion accelerometers. Our study was limited to traditional accelerometers (Fig. 1) and is in no way exhaustive.

  1. Quasi-Static Calibration Method of a High-g Accelerometer

    PubMed Central

    Wang, Yan; Fan, Jinbiao; Zu, Jing; Xu, Peng

    2017-01-01

    To solve the problem of resonance during quasi-static calibration of high-g accelerometers, we deduce the relationship between the minimum excitation pulse width and the resonant frequency of the calibrated accelerometer according to the second-order mathematical model of the accelerometer, and improve the quasi-static calibration theory. We establish a quasi-static calibration testing system, which uses a gas gun to generate high-g acceleration signals, and apply a laser interferometer to reproduce the impact acceleration. These signals are used to drive the calibrated accelerometer. By comparing the excitation acceleration signal and the output responses of the calibrated accelerometer to the excitation signals, the impact sensitivity of the calibrated accelerometer is obtained. As indicated by the calibration test results, this calibration system produces excitation acceleration signals with a pulse width of less than 1000 μs, and realize the quasi-static calibration of high-g accelerometers with a resonant frequency above 20 kHz when the calibration error was 3%. PMID:28230743

  2. New Matching Method for Accelerometers in Gravity Gradiometer

    PubMed Central

    Wei, Hongwei; Wu, Meiping; Cao, Juliang

    2017-01-01

    The gravity gradiometer is widely used in mineral prospecting, including in the exploration of mineral, oil and gas deposits. The mismatch of accelerometers adversely affects the measuring precision of rotating accelerometer-based gravity gradiometers. Several strategies have been investigated to address the imbalance of accelerometers in gradiometers. These strategies, however, complicate gradiometer structures because feedback loops and re-designed accelerometers are needed in these strategies. In this paper, we present a novel matching method, which is based on a new configuration of accelerometers in a gravity gradiometer. In the new configuration, an angle was introduced between the measurement direction of the accelerometer and the spin direction. With the introduced angle, accelerometers could measure the centrifugal acceleration generated by the rotating disc. Matching was realized by updating the scale factors of the accelerometers with the help of centrifugal acceleration. Further simulation computations showed that after adopting the new matching method, signal-to-noise ratio improved from −41 dB to 22 dB. Compared with other matching methods, our method is more flexible and costs less. The matching accuracy of this new method is similar to that of other methods. Our method provides a new idea for matching methods in gravity gradiometer measurement. PMID:28757584

  3. First detection, isolation and molecular characterization of infectious salmon anaemia virus associated with clinical disease in farmed Atlantic salmon (Salmo salar) in Chile

    PubMed Central

    Godoy, Marcos G; Aedo, Alejandra; Kibenge, Molly JT; Groman, David B; Yason, Carmencita V; Grothusen, Horts; Lisperguer, Angelica; Calbucura, Marlene; Avendaño, Fernando; Imilán, Marcelo; Jarpa, Miguel; Kibenge, Frederick SB

    2008-01-01

    Background Infectious salmon anaemia (ISA) is a viral disease of marine-farmed Atlantic salmon (Salmo salar) caused by ISA virus (ISAV), which belongs to the genus Isavirus, family Orthomyxoviridae. The virus is considered to be carried by marine wild fish and for over 25 years has caused major disease outbreaks in marine-farmed Atlantic salmon in the Northern hemisphere. In the Southern hemisphere, ISAV was first detected in Chile in 1999 in marine-farmed Coho salmon (Oncorhynchus kisutch). In contrast to the classical presentation of ISA in Atlantic salmon, the presence of ISAV in Chile until now has only been associated with a clinical condition called Icterus Syndrome in Coho salmon and virus isolation has not always been possible. During the winter of 2007, unexplained mortalities were registered in market-size Atlantic salmon in a grow-out site located in Chiloé in Region X of Chile. We report here the diagnostic findings of the first significant clinical outbreak of ISA in marine-farmed Atlantic salmon in Chile and the first characterization of the ISAV isolated from the affected fish. Results In mid-June 2007, an Atlantic salmon marine farm site located in central Chiloé Island in Region X of Chile registered a sudden increase in mortality following recovery from an outbreak of Pisciricketsiosis, which rose to a cumulative mortality of 13.6% by harvest time. Based on the clinical signs and lesions in the affected fish, and laboratory tests performed on the fish tissues, a confirmatory diagnosis of ISA was made; the first time ISA in its classical presentation and for the first time affecting farmed Atlantic salmon in Chile. Rapid sequencing of the virus-specific RT-PCR products amplified from the fish tissues identified the virus to belong to the European genotype (Genotype I) of the highly polymorphic region (HPR) group HPR 7b, but with an 11-amino acid insert in the fusion glycoprotein, and ability to cause cytopathic effects (CPE) in CHSE-214 cell line, characteristics which make it distinct from common European Genotype ISAV isolates from Europe and North America. Conclusion In conclusion, the present work constitutes the first report of a case of ISA in farmed Atlantic salmon in Chile. The clinical signs and lesions are consistent with the classical descriptions of the disease in marine-farmed Atlantic salmon in the Northern hemisphere. The outbreak was caused by ISAV of European genotype (or Genotype I) of HPR 7b but distinct from common European Genotype ISAV isolates. PMID:18680586

  4. Does the edge effect impact on the measure of spatial accessibility to healthcare providers?

    PubMed

    Gao, Fei; Kihal, Wahida; Le Meur, Nolwenn; Souris, Marc; Deguen, Séverine

    2017-12-11

    Spatial accessibility indices are increasingly applied when investigating inequalities in health. Although most studies are making mentions of potential errors caused by the edge effect, many acknowledge having neglected to consider this concern by establishing spatial analyses within a finite region, settling for hypothesizing that accessibility to facilities will be under-reported. Our study seeks to assess the effect of edge on the accuracy of defining healthcare provider access by comparing healthcare provider accessibility accounting or not for the edge effect, in a real-world application. This study was carried out in the department of Nord, France. The statistical unit we use is the French census block known as 'IRIS' (Ilot Regroupé pour l'Information Statistique), defined by the National Institute of Statistics and Economic Studies. The geographical accessibility indicator used is the "Index of Spatial Accessibility" (ISA), based on the E2SFCA algorithm. We calculated ISA for the pregnant women population by selecting three types of healthcare providers: general practitioners, gynecologists and midwives. We compared ISA variation when accounting or not edge effect in urban and rural zones. The GIS method was then employed to determine global and local autocorrelation. Lastly, we compared the relationship between socioeconomic distress index and ISA, when accounting or not for the edge effect, to fully evaluate its impact. The results revealed that on average ISA when offer and demand beyond the boundary were included is slightly below ISA when not accounting for the edge effect, and we found that the IRIS value was more likely to deteriorate than improve. Moreover, edge effect impact can vary widely by health provider type. There is greater variability within the rural IRIS group than within the urban IRIS group. We found a positive correlation between socioeconomic distress variables and composite ISA. Spatial analysis results (such as Moran's spatial autocorrelation index and local indicators of spatial autocorrelation) are not really impacted. Our research has revealed minor accessibility variation when edge effect has been considered in a French context. No general statement can be set up because intensity of impact varies according to healthcare provider type, territorial organization and methodology used to measure the accessibility to healthcare. Additional researches are required in order to distinguish what findings are specific to a territory and others common to different countries. It constitute a promising direction to determine more precisely healthcare shortage areas and then to fight against social health inequalities.

  5. First detection, isolation and molecular characterization of infectious salmon anaemia virus associated with clinical disease in farmed Atlantic salmon (Salmo salar) in Chile.

    PubMed

    Godoy, Marcos G; Aedo, Alejandra; Kibenge, Molly J T; Groman, David B; Yason, Carmencita V; Grothusen, Horts; Lisperguer, Angelica; Calbucura, Marlene; Avendaño, Fernando; Imilán, Marcelo; Jarpa, Miguel; Kibenge, Frederick S B

    2008-08-04

    Infectious salmon anaemia (ISA) is a viral disease of marine-farmed Atlantic salmon (Salmo salar) caused by ISA virus (ISAV), which belongs to the genus Isavirus, family Orthomyxoviridae. The virus is considered to be carried by marine wild fish and for over 25 years has caused major disease outbreaks in marine-farmed Atlantic salmon in the Northern hemisphere. In the Southern hemisphere, ISAV was first detected in Chile in 1999 in marine-farmed Coho salmon (Oncorhynchus kisutch). In contrast to the classical presentation of ISA in Atlantic salmon, the presence of ISAV in Chile until now has only been associated with a clinical condition called Icterus Syndrome in Coho salmon and virus isolation has not always been possible. During the winter of 2007, unexplained mortalities were registered in market-size Atlantic salmon in a grow-out site located in Chiloé in Region X of Chile. We report here the diagnostic findings of the first significant clinical outbreak of ISA in marine-farmed Atlantic salmon in Chile and the first characterization of the ISAV isolated from the affected fish. In mid-June 2007, an Atlantic salmon marine farm site located in central Chiloé Island in Region X of Chile registered a sudden increase in mortality following recovery from an outbreak of Pisciricketsiosis, which rose to a cumulative mortality of 13.6% by harvest time. Based on the clinical signs and lesions in the affected fish, and laboratory tests performed on the fish tissues, a confirmatory diagnosis of ISA was made; the first time ISA in its classical presentation and for the first time affecting farmed Atlantic salmon in Chile. Rapid sequencing of the virus-specific RT-PCR products amplified from the fish tissues identified the virus to belong to the European genotype (Genotype I) of the highly polymorphic region (HPR) group HPR 7b, but with an 11-amino acid insert in the fusion glycoprotein, and ability to cause cytopathic effects (CPE) in CHSE-214 cell line, characteristics which make it distinct from common European Genotype ISAV isolates from Europe and North America. In conclusion, the present work constitutes the first report of a case of ISA in farmed Atlantic salmon in Chile. The clinical signs and lesions are consistent with the classical descriptions of the disease in marine-farmed Atlantic salmon in the Northern hemisphere. The outbreak was caused by ISAV of European genotype (or Genotype I) of HPR 7b but distinct from common European Genotype ISAV isolates.

  6. Launcher Dynamic Data Acquisition

    DTIC Science & Technology

    2012-07-31

    K PR Pressure PR Pressure PR Accelerometer PR Accelerometer PR Accelerometer PR Pressure PR Pressure IEPE Microphone IEPE ...transducers, displacement potentiometers, or Integrated Electronics Piezoelectric ( IEPE ) microphones and accelerometers. The characteristics of these...Engineering Units HCl hydrogen chloride HVAC heating ventilation and cooling Hz hertz IEC International Electrotechnical Commission IEPE

  7. Design and Implementation of a Micromechanical Silicon Resonant Accelerometer

    PubMed Central

    Huang, Libin; Yang, Hui; Gao, Yang; Zhao, Liye; Liang, Jinxing

    2013-01-01

    The micromechanical silicon resonant accelerometer has attracted considerable attention in the research and development of high-precision MEMS accelerometers because of its output of quasi-digital signals, high sensitivity, high resolution, wide dynamic range, anti-interference capacity and good stability. Because of the mismatching thermal expansion coefficients of silicon and glass, the micromechanical silicon resonant accelerometer based on the Silicon on Glass (SOG) technique is deeply affected by the temperature during the fabrication, packaging and use processes. The thermal stress caused by temperature changes directly affects the frequency output of the accelerometer. Based on the working principle of the micromechanical resonant accelerometer, a special accelerometer structure that reduces the temperature influence on the accelerometer is designed. The accelerometer can greatly reduce the thermal stress caused by high temperatures in the process of fabrication and packaging. Currently, the closed-loop drive circuit is devised based on a phase-locked loop. The unloaded resonant frequencies of the prototype of the micromechanical silicon resonant accelerometer are approximately 31.4 kHz and 31.5 kHz. The scale factor is 66.24003 Hz/g. The scale factor stability is 14.886 ppm, the scale factor repeatability is 23 ppm, the bias stability is 23 μg, the bias repeatability is 170 μg, and the bias temperature coefficient is 0.0734 Hz/°C. PMID:24256978

  8. Calibration and comparison of accelerometer cut points in preschool children.

    PubMed

    van Cauwenberghe, Eveline; Labarque, Valery; Trost, Stewart G; de Bourdeaudhuij, Ilse; Cardon, Greet

    2011-06-01

    The present study aimed to develop accelerometer cut points to classify physical activities (PA) by intensity in preschoolers and to investigate discrepancies in PA levels when applying various accelerometer cut points. To calibrate the accelerometer, 18 preschoolers (5.8 ± 0.4 years) performed eleven structured activities and one free play session while wearing a GT1M ActiGraph accelerometer using 15 s epochs. The structured activities were chosen based on the direct observation system Children's Activity Rating Scale (CARS) while the criterion measure of PA intensity during free play was provided using a second-by-second observation protocol (modified CARS). Receiver Operating Characteristic (ROC) curve analyses were used to determine the accelerometer cut points. To examine the classification differences, accelerometer data of four consecutive days from 114 preschoolers (5.5 ± 0.3 years) were classified by intensity according to previously published and the newly developed accelerometer cut points. Differences in predicted PA levels were evaluated using repeated measures ANOVA and Chi Square test. Cut points were identified at 373 counts/15 s for light (sensitivity: 86%; specificity: 91%; Area under ROC curve: 0.95), 585 counts/15 s for moderate (87%; 82%; 0.91) and 881 counts/15 s for vigorous PA (88%; 91%; 0.94). Further, applying various accelerometer cut points to the same data resulted in statistically and biologically significant differences in PA. Accelerometer cut points were developed with good discriminatory power for differentiating between PA levels in preschoolers and the choice of accelerometer cut points can result in large discrepancies.

  9. The role of the International Society for Applied Ethology (ISAE) in the global development of animal welfare science and its relationship with the OIE; strength through partnership

    USDA-ARS?s Scientific Manuscript database

    The objective of this presentation is to introduce the ISAE and to highlight members’ roles in the development and implementation of OIE’s animal welfare standards. Animal welfare science is a young discipline. Originally, welfare science was heavily focused on animal behavior (ethology), but it is ...

  10. Students' Futures as Investments: The Promise and Challenges of Income-Share Agreements. AEI Series on Private Financing in Higher Education

    ERIC Educational Resources Information Center

    Marcus, Jon

    2016-01-01

    Income-share agreements (ISAs) are an emerging idea for helping students pay for college. Under an ISA, investors provide upfront sums of money toward students' college tuition and other associated costs in exchange for a fixed percentage of the recipients' earnings after graduation. This paper--the first in a series examining private financing in…

  11. Integrated Sensor Architecture (ISA) for Live Virtual Constructive (LVC) Environments

    DTIC Science & Technology

    2014-03-01

    connect, publish their needs and capabilities, and interact with other systems even on disadvantaged networks. Within the ISA project, three levels of...constructive, disadvantaged network, sensor 1. INTRODUCTION In 2003 the Networked Sensors for the Future Force (NSFF) Advanced Technology Demonstration...While this combination is less optimal over disadvantaged networks, and we do not recommend it there, TCP and TLS perform adequately over networks with

  12. Integrated Science Assessment (ISA) for Oxides of Nitrogen, Oxides of Sulfur and Particulate Matter - Ecological Criteria (First External Review Draft, Mar 2017)

    EPA Science Inventory

    This draft ISA document represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision on retaining or revising the current secondary standards for NO2, SO2, PM 2.5 and PM 10 since the prior re...

  13. Country Reports on Terrorism 2007

    DTIC Science & Technology

    2008-04-01

    networks and "sleeper" cells may remain intact and have the capacity to go operational with little warning. Moreover, Malaysian 37 JI operative...continued to conduct all counterterrorist investigations and operations. 41 Malaysian police fall under the authority of the Ministry of...country’s Internal Security Act (ISA), where they undergo a program of rehabilitation. Two-year ISA sentences can be renewed if the Malaysian government

  14. Preparation of Monoclonal Antibodies and a Simple Myeloperoxidase-Immunosorbent Assay for Detecting Human Myeloperoxidase.

    PubMed

    Bian, Zhi-Ping; Li, Xiong-Zhi; Wu, Heng-Fang; Xu, Jin-Dan; Gu, Chun-Rong; Chen, Xiang-Jian; Yang, Di

    2016-04-01

    Myeloperoxidase (MPO), a leukocyte hemoprotein released from neutrophils, is thought to be a potential participant in plaque formation and plaque rupture. Therefore, MPO is regarded as an early marker predicting the risk for atherosclerosis, especially for coronary artery disease and acute coronary syndrome. We generated hybridoma clones 1E3 and 3E8 secreting monoclonal antibodies (mAbs) specific to human MPO. BALB/c mice were immunized with MPO protein purified from human neutrophils. Splenocytes from these mice were fused with the mouse myeloma cell line SP2/0. Based on isotyping of the mAbs, both clones 1E3 and 3E8 were referred to the IgG1 subclass. The specificities of 1E3 and 3E8 were assessed by enzyme-linked immunosorbent assay (ELISA), and only 3E8 was confirmed by western blot. We developed a simple MPO-immunosorbent assay (MPO-ISA) on microplate based on both the immune activity and peroxidase activity of MPO. The mAb secreted by clone 3E8 was chosen as coating antibody to capture the plasma MPO without interfering with the peroxidase activity of MPO. Then, tetramethylbenzidine substrate was added to the microwell directly, catalyzed by captured MPO, and a colored product was formed. The simple MPO-ISA test has a sensitivity of 3.68 ng/mL. The linear concentration of MPO-ISA for commercial MPO standard ranged to 250 ng/mL. The average recovery rate is 101.02%. The imprecision within-day was <10% at three different MPO levels. The imprecision between-day was <10% at low and middle MPO levels and varied to 14.61% at the high MPO level. We found that the established MPO-ISA can detect the plasma MPO from human and cavy, but not from mouse and rat. Compared with the commercial human MPO ELISA assay, the MPO-ISA can be used to detect the natural human MPO protein, but not recombinant MPO polypeptides. The generated mAbs and MPO-ISA test may be useful tools to assess risk for inflammation and cardiac events.

  15. Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET) and the Astromaterial Curation Facility at JAXA/ISAS

    NASA Astrophysics Data System (ADS)

    Yano, H.; Fujiwara, A.

    After the successful launch in May 2003, the Hayabusa (MUSES-C) mission of JAXA/ISAS will collect surface materials (e.g., regolith) of several hundred mg to several g in total from the S-type near Earth asteroid (25143) Itokawa in late 2005 and bring them back to ground laboratories in the summer of 2007. The retrieved samples will be given initial analysis at the JAXA/ISAS astromaterial curation facility, which is currently in the preparation for its construction, by the Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). HASPET is consisted of the ISAS Hayabusa team, the international partners from NASA and Australia and all-Japan meteoritic scientists to be selected as outsourcing parts of the initial analyses. The initial analysis to characterize general aspects of returned samples can consume only 15 % of its total mass and must complete the whole analyses including the database building before international AO for detailed analyses within the maximum of 1 year. Confident exercise of non-destructive, micro-analyses whenever possible are thus vital for the HASPET analysis. In the purpose to survey what kinds and levels of micro-analysis techniques in respective fields, from major elements and mineralogy to trace and isotopic elements and organics, are available in Japan at present, ISAS has conducted the HASPET open competitions in 2000-01 and 2004. The initial evaluation was made by multiple domestic peer reviews. Applicants were then provided two kinds of unknown asteroid sample analogs in order to conduct proposed analysis with self-claimed amount of samples in self-claimed duration. After the completion of multiple, international peer reviews, the Selection Committee compiled evaluations and recommended the finalists of each round. The final members of the HASPET will be appointed about 2 years prior to the Earth return. Then they will conduct a test-run of the whole initial analysis procedures at the ISAS astromaterial curation facility and their respective analysis facilities. This talk also summarizes the curation facility design and plans of initial analysis procedure flow.

  16. Assessment of Differing Definitions of Accelerometer Nonwear Time

    ERIC Educational Resources Information Center

    Evenson, Kelly R.; Terry, James W., Jr.

    2009-01-01

    Measuring physical activity with objective tools, such as accelerometers, is becoming more common. Accelerometers measure acceleration multiple times within a given frequency and summarize this as a count over a pre-specified time period or epoch. The resultant count represents acceleration over the epoch length. Accelerometers eliminate biases…

  17. A Self-Diagnostic System for the M6 Accelerometer

    NASA Technical Reports Server (NTRS)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  18. Coastal Circulation and Potential Disease Pathways Among Aquaculture Sites Near the Eastern U.S.- Canadian Border.

    NASA Astrophysics Data System (ADS)

    Brooks, D. A.

    2002-12-01

    Infectious Salmon Anemia (ISA) is a flu-like virus that can be transmitted between aquaculture sites by tides and currents, contaminated boats and equipment, fish wastes, and ectoparasites. In 1997 ISA outbreaks were reported in Canadian net-pen aquaculture sites in Passamaquoddy Bay, near the mouth of the Bay of Fundy. In March 2001, the first incidence of ISA in the United States occurred at a site near the entrance to Cobscook Bay, about 5 km west of previously infected sites in Canada. In December 2001, it was necessary to destroy Cobscook fish worth about \\12 million at maturity, decimating the local industry. Most net-pen sites are located in protected bays east of Penobscot Bay, Maine, where large tides and cold waters are favorable for aquaculture. Chaotic tidal mixing provides a ready supply of nutrients and oxygen, and also a potential mechanism for ISA transmission within and between coastal bays. In cold water (~6°$C), the ISA virus may remain infective for several days or longer, according to a recent report from a joint government/industry study in Scotland. Recent model studies indicate rapid spreading of neutral particles over distances of 5 km or more, possibly linking Cobscook and Passamaquoddy Bays within a few tidal cycles. On a larger scale, observations and models show the seasonal development of a coastal current that flows southwestward from the Saint John River in the Bay of Fundy toward Penobscot Bay, where the current generally turns offshore to become part of the circulation in the Gulf of Maine. Tidal excursions superimposed on the nontidal coastal current can result in particle displacements of 10-20 km per day, raising concerns about further migration of fish disease pathogens along the Maine coast.

  19. Correlation between static radiographic measurements and intersegmental angular measurements during gait using a multisegment foot model.

    PubMed

    Lee, Dong Yeon; Seo, Sang Gyo; Kim, Eo Jin; Kim, Sung Ju; Lee, Kyoung Min; Farber, Daniel C; Chung, Chin Youb; Choi, In Ho

    2015-01-01

    Radiographic examination is a widely used evaluation method in the orthopedic clinic. However, conventional radiography alone does not reflect the dynamic changes between foot and ankle segments during gait. Multiple 3-dimensional multisegment foot models (3D MFMs) have been introduced to evaluate intersegmental motion of the foot. In this study, we evaluated the correlation between static radiographic indices and intersegmental foot motion indices. One hundred twenty-five females were tested. Static radiographs of full-leg and anteroposterior (AP) and lateral foot views were performed. For hindfoot evaluation, we measured the AP tibiotalar angle (TiTA), talar tilt (TT), calcaneal pitch, lateral tibiocalcaneal angle, and lateral talcocalcaneal angle. For the midfoot segment, naviculocuboid overlap and talonavicular coverage angle were calculated. AP and lateral talo-first metatarsal angles and metatarsal stacking angle (MSA) were measured to assess the forefoot. Hallux valgus angle (HVA) and hallux interphalangeal angle were measured. In gait analysis by 3D MFM, intersegmental angle (ISA) measurements of each segment (hallux, forefoot, hindfoot, arch) were recorded. ISAs at midstance phase were most highly correlated with radiography. Significant correlations were observed between ISA measurements using MFM and static radiographic measurements in the same segment. In the hindfoot, coronal plane ISA was correlated with AP TiTA (P < .001) and TT (P = .018). In the hallux, HVA was strongly correlated with transverse ISA of the hallux (P < .001). The segmental foot motion indices at midstance phase during gait measured by 3D MFM gait analysis were correlated with the conventional radiographic indices. The observed correlation between MFM measurements at midstance phase during gait and static radiographic measurements supports the fundamental basis for the use of MFM in analysis of dynamic motion of foot segment during gait. © The Author(s) 2014.

  20. Symptoms of infectious diseases in immunocompromised travelers: a prospective study with matched controls.

    PubMed

    Baaten, Gijs G; Geskus, Ronald B; Kint, Joan A; Roukens, Anna H E; Sonder, Gerard J; van den Hoek, Anneke

    2011-01-01

    Immunocompromised travelers to developing countries are thought to have symptomatic infectious diseases more often and longer than non-immunocompromised travelers. Evidence for this is lacking. This study evaluates whether immunocompromised short-term travelers are at increased risk of diseases. A prospective study was performed between October 2003 and May 2010 among adult travelers using immunosuppressive agents (ISA) and travelers with inflammatory bowel disease (IBD), with their non-immunocompromised travel companions serving as matched controls with comparable exposure to infection. Data on symptoms of infectious diseases were recorded by using a structured diary. Among 75 ISA, the incidence of travel-related diarrhea was 0.76 per person-month, and the number of symptomatic days 1.32 per month. For their 75 controls, figures were 0.66 and 1.50, respectively (p > 0.05). Among 71 IBD, the incidence was 1.19, and the number of symptomatic days was 2.48. For their 71 controls, figures were 0.73 and 1.31, respectively (p > 0.05). These differences also existed before travel. ISA had significantly more and longer travel-related signs of skin infection and IBD suffered more and longer from vomiting. As for other symptoms, no significant travel-related differences were found. Only 21% of immunocompromised travelers suffering from diarrhea used their stand-by antibiotics. ISA and IBD did not have symptomatic infectious diseases more often or longer than non-immunocompromised travelers, except for signs of travel-related skin infection among ISA. Routine prescription of stand-by antibiotics for these immunocompromised travelers to areas with good health facilities is probably not more useful than for healthy travelers. © 2011 International Society of Travel Medicine.

  1. The Development of a Dual-Warhead Impact System for Dynamic Linearity Measurement of a High-g Micro-Electro-Mechanical-Systems (MEMS) Accelerometer

    PubMed Central

    Shi, Yunbo; Yang, Zhicai; Ma, Zongmin; Cao, Huiliang; Kou, Zhiwei; Zhi, Dan; Chen, Yanxiang; Feng, Hengzhen; Liu, Jun

    2016-01-01

    Despite its extreme significance, dynamic linearity measurement for high-g accelerometers has not been discussed experimentally in previous research. In this study, we developed a novel method using a dual-warhead Hopkinson bar to measure the dynamic linearity of a high-g acceleration sensor with a laser interference impact experiment. First, we theoretically determined that dynamic linearity is a performance indicator that can be used to assess the quality merits of high-g accelerometers and is the basis of the frequency response. We also found that the dynamic linearity of the dual-warhead Hopkinson bar without an accelerometer is 2.5% experimentally. Further, we verify that dynamic linearity of the accelerometer is 3.88% after calibrating the Hopkinson bar with the accelerometer. The results confirm the reliability and feasibility of measuring dynamic linearity for high-g accelerometers using this method. PMID:27338383

  2. A biomimetic accelerometer inspired by the cricket's clavate hair

    PubMed Central

    Droogendijk, H.; de Boer, M. J.; Sanders, R. G. P.; Krijnen, G. J. M.

    2014-01-01

    Crickets use so-called clavate hairs to sense (gravitational) acceleration to obtain information on their orientation. Inspired by this clavate hair system, a one-axis biomimetic accelerometer has been developed and fabricated using surface micromachining and SU-8 lithography. An analytical model is presented for the design of the accelerometer, and guidelines are derived to reduce responsivity due to flow-induced contributions to the accelerometer's output. Measurements show that this microelectromechanical systems (MEMS) hair-based accelerometer has a resonance frequency of 320 Hz, a detection threshold of 0.10 ms−2 and a dynamic range of more than 35 dB. The accelerometer exhibits a clear directional response to external accelerations and a low responsivity to airflow. Further, the accelerometer's physical limits with respect to noise levels are addressed and the possibility for short-term adaptation of the sensor to the environment is discussed. PMID:24920115

  3. Dual Accelerometer Usage Strategy for Onboard Space Navigation

    NASA Technical Reports Server (NTRS)

    Zanetti, Renato; D'Souza, Chris

    2012-01-01

    This work introduces a dual accelerometer usage strategy for onboard space navigation. In the proposed algorithm the accelerometer is used to propagate the state when its value exceeds a threshold and it is used to estimate its errors otherwise. Numerical examples and comparison to other accelerometer usage schemes are presented to validate the proposed approach.

  4. Integrated Science Assessment (ISA) for Sulfur Oxides ...

    EPA Pesticide Factsheets

    EPA announced the availability of the final report, Integrated Science Assessment (ISA) for Sulfur Oxides – Health Criteria final assessment. This report represents a concise synthesis and evaluation of the most policy-relevant science and will ultimately provide the scientific bases for EPA’s decision regarding whether the current standard for oxides of sulfur (SO2) sufficiently protects public health. The Integrated Plan for Review of the Primary NAAQS for SOx U.S. 2: EPA (2007) identifies key policy-relevant questions that provide a framework for this review of the scientific evidence. These questions frame the entire review of the NAAQS, and thus are informed by both science and policy considerations. The ISA organizes and presents the scientific evidence such that, when considered along with findings from risk analyses and policy considerations, will help the EPA address these questions in completing the NAAQS review.

  5. The analysis of temperature effect and temperature compensation of MOEMS accelerometer based on a grating interferometric cavity

    NASA Astrophysics Data System (ADS)

    Han, Dandan; Bai, Jian; Lu, Qianbo; Lou, Shuqi; Jiao, Xufen; Yang, Guoguang

    2016-08-01

    There is a temperature drift of an accelerometer attributed to the temperature variation, which would adversely influence the output performance. In this paper, a quantitative analysis of the temperature effect and the temperature compensation of a MOEMS accelerometer, which is composed of a grating interferometric cavity and a micromachined sensing chip, are proposed. A finite-element-method (FEM) approach is applied in this work to simulate the deformation of the sensing chip of the MOEMS accelerometer at different temperature from -20°C to 70°C. The deformation results in the variation of the distance between the grating and the sensing chip of the MOEMS accelerometer, modulating the output intensities finally. A static temperature model is set up to describe the temperature characteristics of the accelerometer through the simulation results and the temperature compensation is put forward based on the temperature model, which can improve the output performance of the accelerometer. This model is permitted to estimate the temperature effect of this type accelerometer, which contains a micromachined sensing chip. Comparison of the output intensities with and without temperature compensation indicates that the temperature compensation can improve the stability of the output intensities of the MOEMS accelerometer based on a grating interferometric cavity.

  6. Using tri-axial accelerometers to identify wild polar bear behaviors

    USGS Publications Warehouse

    Pagano, Anthony M.; Rode, Karyn D.; Cutting, A.; Owen, M.A.; Jensen, S.; Ware, J.V.; Robbins, C.T.; Durner, George M.; Atwood, Todd C.; Obbard, M.E.; Middel, K.R.; Thiemann, G.W.; Williams, T.M.

    2017-01-01

    Tri-axial accelerometers have been used to remotely identify the behaviors of a wide range of taxa. Assigning behaviors to accelerometer data often involves the use of captive animals or surrogate species, as their accelerometer signatures are generally assumed to be similar to those of their wild counterparts. However, this has rarely been tested. Validated accelerometer data are needed for polar bears Ursus maritimus to understand how habitat conditions may influence behavior and energy demands. We used accelerometer and water conductivity data to remotely distinguish 10 polar bear behaviors. We calibrated accelerometer and conductivity data collected from collars with behaviors observed from video-recorded captive polar bears and brown bears U. arctos, and with video from camera collars deployed on free-ranging polar bears on sea ice and on land. We used random forest models to predict behaviors and found strong ability to discriminate the most common wild polar bear behaviors using a combination of accelerometer and conductivity sensor data from captive or wild polar bears. In contrast, models using data from captive brown bears failed to reliably distinguish most active behaviors in wild polar bears. Our ability to discriminate behavior was greatest when species- and habitat-specific data from wild individuals were used to train models. Data from captive individuals may be suitable for calibrating accelerometers, but may provide reduced ability to discriminate some behaviors. The accelerometer calibrations developed here provide a method to quantify polar bear behaviors to evaluate the impacts of declines in Arctic sea ice.

  7. Optimal accelerometer placement on a robot arm for pose estimation

    NASA Astrophysics Data System (ADS)

    Wijayasinghe, Indika B.; Sanford, Joseph D.; Abubakar, Shamsudeen; Saadatzi, Mohammad Nasser; Das, Sumit K.; Popa, Dan O.

    2017-05-01

    The performance of robots to carry out tasks depends in part on the sensor information they can utilize. Usually, robots are fitted with angle joint encoders that are used to estimate the position and orientation (or the pose) of its end-effector. However, there are numerous situations, such as in legged locomotion, mobile manipulation, or prosthetics, where such joint sensors may not be present at every, or any joint. In this paper we study the use of inertial sensors, in particular accelerometers, placed on the robot that can be used to estimate the robot pose. Studying accelerometer placement on a robot involves many parameters that affect the performance of the intended positioning task. Parameters such as the number of accelerometers, their size, geometric placement and Signal-to-Noise Ratio (SNR) are included in our study of their effects for robot pose estimation. Due to the ubiquitous availability of inexpensive accelerometers, we investigated pose estimation gains resulting from using increasingly large numbers of sensors. Monte-Carlo simulations are performed with a two-link robot arm to obtain the expected value of an estimation error metric for different accelerometer configurations, which are then compared for optimization. Results show that, with a fixed SNR model, the pose estimation error decreases with increasing number of accelerometers, whereas for a SNR model that scales inversely to the accelerometer footprint, the pose estimation error increases with the number of accelerometers. It is also shown that the optimal placement of the accelerometers depends on the method used for pose estimation. The findings suggest that an integration-based method favors placement of accelerometers at the extremities of the robot links, whereas a kinematic-constraints-based method favors a more uniformly distributed placement along the robot links.

  8. Comparison of Physical Activity Adult Questionnaire results with accelerometer data.

    PubMed

    Garriguet, Didier; Tremblay, Sylvain; Colley, Rachel C

    2015-07-01

    Discrepancies between self-reported and objectively measured physical activity are well-known. For the purpose of validation, this study compares a new self-reported physical activity questionnaire with an existing one and with accelerometer data. Data collected at one site of the Canadian Health Measures Survey in 2013 were used for this validation study. The International Physical Activity Questionnaire (IPAQ) was administered to respondents during the household interview, and the new Physical Activity for Adults Questionnaire (PAAQ) was administered during a subsequent visit to a mobile examination centre (MEC). At the MEC, respondents were given an accelerometer to wear for seven days. The analysis pertains to 112 respondents aged 18 to 79 who wore the accelerometer for 10 or more hours on at least four days. Moderate-to-vigorous physical activity (MVPA) measured by accelerometer had higher correlation with data from the PAAQ (r = 0.44) than with data from the IPAQ (r = 0.20). The differences between accelerometer and PAAQ data were greater based on accelerometer-measured physical activity accumulated in 10-minute bouts (30-minute difference in MVPA) than on all minutes (9-minute difference). The percentages of respondents meeting the Canadian Physical Activity Guidelines were 90% based on self-reported IPAQ minutes, 70% based on all accelerometer MVPA minutes, 29% based on accelerometer MVPA minutes accumulated in 10-minute bouts, and 61% based on self-reported PAAQ minutes. The PAAQ demonstrated reasonable validity against the accelerometer criterion. Based on correlations and absolute differences between daily minutes of MVPA and the percentages of respondents meeting the Canadian Physical Activity Guidelines, PAAQ results were closer to accelerometer data than were the IPAQ results for the study sample and previous Statistics Canada self-reported questionnaire findings.

  9. Accelerometer-based measures in physical activity surveillance: current practices and issues.

    PubMed

    Pedišić, Željko; Bauman, Adrian

    2015-02-01

    Self-reports of physical activity (PA) have been the mainstay of measurement in most non-communicable disease (NCD) surveillance systems. To these, other measures are added to summate to a comprehensive PA surveillance system. Recently, some national NCD surveillance systems have started using accelerometers as a measure of PA. The purpose of this paper was specifically to appraise the suitability and role of accelerometers for population-level PA surveillance. A thorough literature search was conducted to examine aspects of the generalisability, reliability, validity, comprehensiveness and between-study comparability of accelerometer estimates, and to gauge the simplicity, cost-effectiveness, adaptability and sustainability of their use in NCD surveillance. Accelerometer data collected in PA surveillance systems may not provide estimates that are generalisable to the target population. Accelerometer-based estimates have adequate reliability for PA surveillance, but there are still several issues associated with their validity. Accelerometer-based prevalence estimates are largely dependent on the investigators' choice of intensity cut-off points. Maintaining standardised accelerometer data collections in long-term PA surveillance systems is difficult, which may cause discontinuity in time-trend data. The use of accelerometers does not necessarily produce useful between-study and international comparisons due to lack of standardisation of data collection and processing methods. To conclude, it appears that accelerometers still have limitations regarding generalisability, validity, comprehensiveness, simplicity, affordability, adaptability, between-study comparability and sustainability. Therefore, given the current evidence, it seems that the widespread adoption of accelerometers specifically for large-scale PA surveillance systems may be premature. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Temperature and frequency dependence of anelasticity in a nickel oscillator

    NASA Astrophysics Data System (ADS)

    Berg, Robert F.

    1995-09-01

    The frequency dependence of the real and imaginary parts of a nickel oscillator's transfer function is described over 3 decades in frequency by the use of simple expressions. These expressions incorporate only the resonance frequency ω0, the quality factor Q, and a characteristic exponent β determined by a single measurement of creep. They are based on the ansatz φ(ω)=Q-1(ω/ω0)-β, where φ is the imaginary part of the spring constant. Over a 100 K range of temperature T, the exponent β≂0.18 was constant even though Q(T) changed by a factor of 8. These expressions are potentially useful for accurately describing a mechanical oscillator whose transfer function must be modeled at frequencies far below ω0. Examples include accelerometers based on a flexure element and suspensions for interferometric gravitational wave detectors.

  11. Analysis of linear head accelerations from collegiate football impacts.

    PubMed

    Brolinson, P Gunnar; Manoogian, Sarah; McNeely, David; Goforth, Mike; Greenwald, Richard; Duma, Stefan

    2006-02-01

    Sports-related concussions result in 300,000 brain injuries in the United States each year. We conducted a study utilizing an in-helmet system that measures and records linear head accelerations to analyze head impacts in collegiate football. The Head Impact Telemetry (HIT) System is an in-helmet system with six spring-mounted accelerometers and an antenna that transmits data via radio frequency to a sideline receiver and laptop computer system. A total of 11,604 head impacts were recorded from the Virginia Tech football team throughout the 2003 and 2004 football seasons during 22 games and 62 practices from a total of 52 players. Although the incidence of injury data are limited, this study presents an extremely large data set from human head impacts that provides valuable insight into the lower limits of head acceleration that cause mild traumatic brain injuries.

  12. ISA-97 Compliant Architecture Testbed (ICAT) Projectry Organizations

    DTIC Science & Technology

    1992-03-30

    by the System Integracion Directorate of the USAISEC, August 29, 1992. The report discusses the refinement of the ISA-97 Compliant Architecture Model...browser and iconic representations of system objects and resources. When the user is interacting with an application which has multiple compo- nents, it is...computer communications, it is not uncommon for large information systems to be shared by users on multiple machines. The trend towards the desktop

  13. The private life of echidnas: using accelerometry and GPS to examine field biomechanics and assess the ecological impact of a widespread, semi-fossorial monotreme.

    PubMed

    Clemente, Christofer J; Cooper, Christine E; Withers, Philip C; Freakley, Craig; Singh, Surya; Terrill, Philip

    2016-10-15

    The short-beaked echidna (Tachyglossus aculeatus) is a monotreme and therefore provides a unique combination of phylogenetic history, morphological differentiation and ecological specialisation for a mammal. The echidna has a unique appendicular skeleton, a highly specialised myrmecophagous lifestyle and a mode of locomotion that is neither typically mammalian nor reptilian, but has aspects of both lineages. We therefore were interested in the interactions of locomotor biomechanics, ecology and movements for wild, free-living short-beaked echidnas. To assess locomotion in its complex natural environment, we attached both GPS and accelerometer loggers to the back of echidnas in both spring and summer. We found that the locomotor biomechanics of echidnas is unique, with lower stride length and stride frequency than reported for similar-sized mammals. Speed modulation is primarily accomplished through changes in stride frequency, with a mean of 1.39 Hz and a maximum of 2.31 Hz. Daily activity period was linked to ambient air temperature, which restricted daytime activity during the hotter summer months. Echidnas had longer activity periods and longer digging bouts in spring compared with summer. In summer, echidnas had higher walking speeds than in spring, perhaps because of the shorter time suitable for activity. Echidnas spent, on average, 12% of their time digging, which indicates their potential to excavate up to 204 m 3 of soil a year. This information highlights the important contribution towards ecosystem health, via bioturbation, of this widespread Australian monotreme. © 2016. Published by The Company of Biologists Ltd.

  14. Molecular Identification of Sex in Phoenix dactylifera Using Inter Simple Sequence Repeat Markers.

    PubMed

    Al-Ameri, Abdulhafed A; Al-Qurainy, Fahad; Gaafar, Abdel-Rhman Z; Khan, Salim; Nadeem, M

    2016-01-01

    Early sex identification of Date Palm (Phoenix dactylifera L.) at seedling stage is an economically desirable objective, which will significantly increase the profits of seed based cultivation. The utilization of molecular markers at this stage for early and rapid identification of sex is important due to the lack of morphological markers. In this study, a total of two hundred Inter Simple Sequence Repeat (ISSR) primers were screened among male and female Date palm plants to identify putative sex-specific marker, out of which only two primers (IS_A02 and IS_A71) were found to be associated with sex. The primer IS_A02 produced a unique band of size 390 bp and was found clearly in all female plants, while it was absent in all male plants. Contrary to this, the primer IS_A71 produced a unique band of size 380 bp and was clearly found in all male plants, whereas it was absent in all the female plants. Subsequently, these specific fragments were excised, purified, and sequenced for the development of sequence specific markers further in future for the implementation on dioecious Date Palm for sex determination. These markers are efficient, highly reliable, and reproducible for sex identification at the early stage of seedling.

  15. [Effects of beta blockers on lipoprotein metabolism].

    PubMed

    Ritter, M M; Richter, W O; Schwandt, P

    1992-10-10

    With respect to prevention of its most common complication--mortality from coronary heart disease--treatment of hypertension had disappointed. It is possible that this is due to negative effects of antihypertensives on lipid metabolism. The effects of beta blockers on lipid metabolism can be differentiated principally, in accordance with the classification of beta blockers into those with and those without intrinsic sympathomimetic activity (ISA), as also selectivity and non-selectivity. Thus, non-selective beta blockers with no ISA usually lead to an increase in triglycerides of 25% to 30%, and a decrease in HDL cholesterol of about 15%. On average, beta-1 selective blockers result in a smaller increase in triglycerides. Beta blockers with ISA, in contrast, are largely neutral vis-à-vis lipid metabolism. In the individual case, in particular in the presence of hyperlipoproteinemia, the effects cannot be reliably predicted. Lipoprotein concentrations should be monitored during treatment with beta blockers. If necessary, a change in the agent employed is recommended. In the case of prevention of a second myocardial infarction, for which various studies have unequivocally shown a reduction in mortality associated with treatment with beta blockers with no ISA, these side effects will, however, be accepted--with the exception of extreme changes--for a limited period of time.

  16. The Problems with the Kappa Statistic as a Metric of Interobserver Agreement on Lesion Detection Using a Third-reader Approach When Locations Are Not Prespecified.

    PubMed

    Shih, Joanna H; Greer, Matthew D; Turkbey, Baris

    2018-03-16

    To point out the problems with Cohen kappa statistic and to explore alternative metrics to determine interobserver agreement on lesion detection when locations are not prespecified. Use of kappa and two alternative methods, namely index of specific agreement (ISA) and modified kappa, for measuring interobserver agreement on the location of detected lesions are presented. These indices of agreement are illustrated by application to a retrospective multireader study in which nine readers detected and scored prostate cancer lesions in 163 consecutive patients (n = 110 cases, n = 53 controls) using the guideline of Prostate Imaging Reporting and Data System version 2 on multiparametric magnetic resonance imaging. The proposed modified kappa, which properly corrects for the amount of agreement by chance, is shown to be approximately equivalent to the ISA. In the prostate cancer data, average kappa, modified kappa, and ISA equaled 30%, 55%, and 57%, respectively, for all lesions and 20%, 87%, and 87%, respectively, for index lesions. The application of kappa could result in a substantial downward bias in reader agreement on lesion detection when locations are not prespecified. ISA is recommended for assessment of reader agreement on lesion detection. Published by Elsevier Inc.

  17. A simple statistical method for analyzing flood susceptibility with incorporating rainfall and impervious surface

    NASA Astrophysics Data System (ADS)

    Chiang, Shou-Hao; Chen, Chi-Farn

    2016-04-01

    Flood, as known as the most frequent natural hazard in Taiwan, has induced severe damages of residents and properties in urban areas. The flood risk is even more severe in Tainan since 1990s, with the significant urban development over recent decades. Previous studies have indicated that the characteristics and the vulnerability of flood are affected by the increase of impervious surface area (ISA) and the changing climate condition. Tainan City, in southern Taiwan is selected as the study area. This study uses logistic regression to functionalize the relationship between rainfall variables, ISA and historical flood events. Specifically, rainfall records from 2001 to 2014 were collected and mapped, and Landsat images of year 2001, 2004, 2007, 2010 and 2014 were used to generate the ISA with SVM (support vector machine) classifier. The result shows that rainfall variables and ISA are significantly correlated to the flood occurrence in Tainan City. With applying the logistic function, the likelihood of flood occurrence can be estimated and mapped over the study area. This study suggests the method is simple and feasible for rapid flood susceptibility mapping, when real-time rainfall observations can be available, and it has potential for future flood assessment, with incorporating climate change projections and urban growth prediction.

  18. Improving automation standards via semantic modelling: Application to ISA88.

    PubMed

    Dombayci, Canan; Farreres, Javier; Rodríguez, Horacio; Espuña, Antonio; Graells, Moisès

    2017-03-01

    Standardization is essential for automation. Extensibility, scalability, and reusability are important features for automation software that rely in the efficient modelling of the addressed systems. The work presented here is from the ongoing development of a methodology for semi-automatic ontology construction methodology from technical documents. The main aim of this work is to systematically check the consistency of technical documents and support the improvement of technical document consistency. The formalization of conceptual models and the subsequent writing of technical standards are simultaneously analyzed, and guidelines proposed for application to future technical standards. Three paradigms are discussed for the development of domain ontologies from technical documents, starting from the current state of the art, continuing with the intermediate method presented and used in this paper, and ending with the suggested paradigm for the future. The ISA88 Standard is taken as a representative case study. Linguistic techniques from the semi-automatic ontology construction methodology is applied to the ISA88 Standard and different modelling and standardization aspects that are worth sharing with the automation community is addressed. This study discusses different paradigms for developing and sharing conceptual models for the subsequent development of automation software, along with presenting the systematic consistency checking method. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  19. Framework for assessing causality of air pollution-related health effects for reviews of the National Ambient Air Quality Standards.

    PubMed

    Owens, Elizabeth Oesterling; Patel, Molini M; Kirrane, Ellen; Long, Thomas C; Brown, James; Cote, Ila; Ross, Mary A; Dutton, Steven J

    2017-08-01

    To inform regulatory decisions on the risk due to exposure to ambient air pollution, consistent and transparent communication of the scientific evidence is essential. The United States Environmental Protection Agency (U.S. EPA) develops the Integrated Science Assessment (ISA), which contains evaluations of the policy-relevant science on the effects of criteria air pollutants and conveys critical science judgments to inform decisions on the National Ambient Air Quality Standards. This article discusses the approach and causal framework used in the ISAs to evaluate and integrate various lines of scientific evidence and draw conclusions about the causal nature of air pollution-induced health effects. The framework has been applied to diverse pollutants and cancer and noncancer effects. To demonstrate its flexibility, we provide examples of causality judgments on relationships between health effects and pollutant exposures, drawing from recent ISAs for ozone, lead, carbon monoxide, and oxides of nitrogen. U.S. EPA's causal framework has increased transparency by establishing a structured process for evaluating and integrating various lines of evidence and uniform approach for determining causality. The framework brings consistency and specificity to the conclusions in the ISA, and the flexibility of the framework makes it relevant for evaluations of evidence across media and health effects. Published by Elsevier Inc.

  20. Nordic Walking and the Isa Method for Breast Cancer Survivors: Effects on Upper Limb Circumferences and Total Body Extracellular Water - a Pilot Study.

    PubMed

    Di Blasio, Andrea; Morano, Teresa; Napolitano, Giorgio; Bucci, Ines; Di Santo, Serena; Gallina, Sabina; Cugusi, Lucia; Di Donato, Francesco; D'Arielli, Alberto; Cianchetti, Ettore

    2016-12-01

    The negative side effects of breast cancer treatments can include upper limb lymphoedema. The growing literature indicates that Nordic walking is an effective discipline against several disease symptoms. The aim of this study was to determine whether introduction to Nordic walking alone is effective against total body extracellular water and upper limb circumferences in breast cancer survivors compared to its combination with a series of specifically created exercises (i.e. the Isa method). 16 breast cancer survivors (49.09 ± 2.24 years) were recruited and randomly assigned to 1 of 2 different training groups. 10 lessons on Nordic walking technique plus the Isa method significantly reduced both extracellular body water and the extracellular-to-total body water ratio (p = 0.01 for both), and also the circumference of the upper limb, (both relaxed arm and forearm circumferences) (p = 0.01 for all), whereas Nordic walking alone did not. Introduction to Nordic walking does not seem to affect lymphoedema in breast cancer survivors. This might be because novice Nordic Walkers do not adequately generate an effective muscular pump through coordination of the alternated bimanual open-close cycle. The Isa method appears to close this gap.

  1. Nordic Walking and the Isa Method for Breast Cancer Survivors: Effects on Upper Limb Circumferences and Total Body Extracellular Water - a Pilot Study

    PubMed Central

    Di Blasio, Andrea; Morano, Teresa; Napolitano, Giorgio; Bucci, Ines; Di Santo, Serena; Gallina, Sabina; Cugusi, Lucia; Di Donato, Francesco; D'Arielli, Alberto; Cianchetti, Ettore

    2016-01-01

    Background The negative side effects of breast cancer treatments can include upper limb lymphoedema. The growing literature indicates that Nordic walking is an effective discipline against several disease symptoms. The aim of this study was to determine whether introduction to Nordic walking alone is effective against total body extracellular water and upper limb circumferences in breast cancer survivors compared to its combination with a series of specifically created exercises (i.e. the Isa method). Methods 16 breast cancer survivors (49.09 ± 2.24 years) were recruited and randomly assigned to 1 of 2 different training groups. Results 10 lessons on Nordic walking technique plus the Isa method significantly reduced both extracellular body water and the extracellular-to-total body water ratio (p = 0.01 for both), and also the circumference of the upper limb, (both relaxed arm and forearm circumferences) (p = 0.01 for all), whereas Nordic walking alone did not. Conclusions Introduction to Nordic walking does not seem to affect lymphoedema in breast cancer survivors. This might be because novice Nordic Walkers do not adequately generate an effective muscular pump through coordination of the alternated bimanual open-close cycle. The Isa method appears to close this gap. PMID:28228712

  2. Localization of A-type K+ channel subunit Kv4.2 in rat brain.

    PubMed

    Tsaur, M L; Wu, Y L; Huang, F L; Shih, Y H

    2001-09-30

    Kv4.2, a voltage-gated K+ (Kv) channel subunit, has been suggested to be the key component of the subthreshold A-type K+ currents (I(SA)s) recorded from the specific subcellular compartments of certain CNS neurons. To correlate Kv4.2 localization with the I(SA)s detected, immunohistochemistry will be useful. Although the Kv4.2 immunostaining pattern in the hippocampus and cerebellum has been reported, the Kv4.2 antibody used was not specific. Furthermore, Kv4.2 localization in other brain regions remains unclear. In this report, we first demonstrated the specificity of a new Kv4.2 antibody, and then used it to examine Kv4.2 localization throughout adult rat brain by immunohistochemistry. At the cellular level, Kv4.2 was found in neurons but not glias. At the subcellular level, Kv4.2 was localized in the somatodendritic compartment of most neurons examined. Nevertheless, our preliminary data indicated that Kv4.2 might be also present in the axon/terminal compartment. At the functional level, our data indicates that Kv4.2 localization and I(SA) correlate quite well in some CNS neurons, supporting that Kv4.2 is the key component of some I(SA)s recorded in vivo.

  3. Adaptive control of nonlinear uncertain active suspension systems with prescribed performance.

    PubMed

    Huang, Yingbo; Na, Jing; Wu, Xing; Liu, Xiaoqin; Guo, Yu

    2015-01-01

    This paper proposes adaptive control designs for vehicle active suspension systems with unknown nonlinear dynamics (e.g., nonlinear spring and piece-wise linear damper dynamics). An adaptive control is first proposed to stabilize the vertical vehicle displacement and thus to improve the ride comfort and to guarantee other suspension requirements (e.g., road holding and suspension space limitation) concerning the vehicle safety and mechanical constraints. An augmented neural network is developed to online compensate for the unknown nonlinearities, and a novel adaptive law is developed to estimate both NN weights and uncertain model parameters (e.g., sprung mass), where the parameter estimation error is used as a leakage term superimposed on the classical adaptations. To further improve the control performance and simplify the parameter tuning, a prescribed performance function (PPF) characterizing the error convergence rate, maximum overshoot and steady-state error is used to propose another adaptive control. The stability for the closed-loop system is proved and particular performance requirements are analyzed. Simulations are included to illustrate the effectiveness of the proposed control schemes. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  4. A universal, accurate intensity-based classification of different physical activities using raw data of accelerometer.

    PubMed

    Vähä-Ypyä, Henri; Vasankari, Tommi; Husu, Pauliina; Suni, Jaana; Sievänen, Harri

    2015-01-01

    Accelerometers are increasingly used for objective assessment of physical activity. However, because of lack of the proprietary analysis algorithms, direct comparisons between accelerometer brands are difficult. In this study, we propose and evaluate open source methods for commensurate assessment of raw accelerometer data irrespective of the brand. Twenty-one participants carried simultaneously three different tri-axial accelerometers on their waist during five different sedentary activities and five different intensity levels of bipedal movement from slow walking to running. Several time and frequency domain traits were calculated from the measured raw data, and their performance in classifying the activities was compared. Of the several traits, the mean amplitude deviation (MAD) provided consistently the best performance in separating the sedentary activities and different speeds of bipedal movement from each other. Most importantly, the universal cut-off limits based on MAD classified sedentary activities and different intensity levels of walking and running equally well for all three accelerometer brands and reached at least 97% sensitivity and specificity in each case. Irrespective of the accelerometer brand, a simply calculable MAD with universal cut-off limits provides a universal method to evaluate physical activity and sedentary behaviour using raw accelerometer data. A broader application of the present approach is expected to render different accelerometer studies directly comparable with each other. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  5. Self Diagnostic Accelerometer Testing on the C-17 Aircraft

    NASA Technical Reports Server (NTRS)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. To demonstrate the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The SDA attachment conditions were varied from fully tight to loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first.

  6. A brief test of the Hewlett-Packard MEMS seismic accelerometer

    USGS Publications Warehouse

    Homeijer, Brian D.; Milligan, Donald J.; Hutt, Charles R.

    2014-01-01

    Testing was performed on a prototype of Hewlett-Packard (HP) Micro-Electro-Mechanical Systems (MEMS) seismic accelerometer at the U.S. Geological Survey’s Albuquerque Seismological Laboratory. This prototype was built using discrete electronic components. The self-noise level was measured during low seismic background conditions and found to be 9.8 ng/√Hz at periods below 0.2 s (frequencies above 5 Hz). The six-second microseism noise was also discernible. The HP MEMS accelerometer was compared to a Geotech Model GS-13 reference seismometer during seismic noise and signal levels well above the self-noise of the accelerometer. Matching power spectral densities (corrected for accelerometer and seismometer responses to represent true ground motion) indicated that the HP MEMS accelerometer has a flat (constant) response to acceleration from 0.0125 Hz to at least 62.5 Hz. Tilt calibrations of the HP MEMS accelerometer verified that the flat response to acceleration extends to 0 Hz. Future development of the HP MEMS accelerometer includes replacing the discreet electronic boards with a low power application-specific integrated circuit (ASIC) and increasing the dynamic range of the sensor to detect strong motion signals above one gravitational acceleration, while maintaining the self-noise observed during these tests.

  7. Vibration sensing in smart machine rotors using internal MEMS accelerometers

    NASA Astrophysics Data System (ADS)

    Jiménez, Samuel; Cole, Matthew O. T.; Keogh, Patrick S.

    2016-09-01

    This paper presents a novel topology for enhanced vibration sensing in which wireless MEMS accelerometers embedded within a hollow rotor measure vibration in a synchronously rotating frame of reference. Theoretical relations between rotor-embedded accelerometer signals and the vibration of the rotor in an inertial reference frame are derived. It is thereby shown that functionality as a virtual stator-mounted displacement transducer can be achieved through appropriate signal processing. Experimental tests on a prototype rotor confirm that both magnitude and phase information of synchronous vibration can be measured directly without additional stator-mounted key-phasor sensors. Displacement amplitudes calculated from accelerometer signals will become erroneous at low rotational speeds due to accelerometer zero-g offsets, hence a corrective procedure is introduced. Impact tests are also undertaken to examine the ability of the internal accelerometers to measure transient vibration. A further capability is demonstrated, whereby the accelerometer signals are used to measure rotational speed of the rotor by analysing the signal component due to gravity. The study highlights the extended functionality afforded by internal accelerometers and demonstrates the feasibility of internal sensor topologies, which can provide improved observability of rotor vibration at externally inaccessible rotor locations.

  8. Design, Simulation and Fabrication of Triaxial MEMS High Shock Accelerometer.

    PubMed

    Zhang, Zhenhai; Shi, Zhiguo; Yang, Zhan; Xie, Zhihong; Zhang, Donghong; Cai, De; Li, Kejie; Shen, Yajing

    2015-04-01

    On the basis of analyzing the disadvantage of other structural accelerometer, three-axis high g MEMS piezoresistive accelerometer was put forward in order to apply to the high-shock test field. The accelerometer's structure and working principle were discussed in details. The simulation results show that three-axis high shock MEMS accelerometer can bear high shock. After bearing high shock impact in high-shock shooting test, three-axis high shock MEMS accelerometer can obtain the intact metrical information of the penetration process and still guarantee the accurate precision of measurement in high shock load range, so we can not only analyze the law of stress wave spreading and the penetration rule of the penetration process of the body of the missile, but also furnish the testing technology of the burst point controlling. The accelerometer has far-ranging application in recording the typical data that projectile penetrating hard target and furnish both technology guarantees for penetration rule and defend engineering.

  9. Using the GOCE star trackers for validating the calibration of its accelerometers

    NASA Astrophysics Data System (ADS)

    Visser, P. N. A. M.

    2017-12-01

    A method for validating the calibration parameters of the six accelerometers on board the Gravity field and steady-state Ocean Circulation Explorer (GOCE) from star tracker observations that was originally tested by an end-to-end simulation, has been updated and applied to real data from GOCE. It is shown that the method provides estimates of scale factors for all three axes of the six GOCE accelerometers that are consistent at a level significantly better than 0.01 compared to the a priori calibrated value of 1. In addition, relative accelerometer biases and drift terms were estimated consistent with values obtained by precise orbit determination, where the first GOCE accelerometer served as reference. The calibration results clearly reveal the different behavior of the sensitive and less-sensitive accelerometer axes.

  10. The Iran Sanctions Act (ISA)

    DTIC Science & Technology

    2009-06-04

    billion4 contract (September 1997) for Total SA of France and its partners, Gazprom of Russia and Petronas of Malaysia to develop phases 2 and 3 of the 25...companies. On July 12, 2008, Total and Petronas , the original South Pars investors, pulled out of a deal to develop a liquified natural gas (LNG...do not exceed the $20 million in one year threshold for ISA sanctionability. Since the Total/ Petronas /Gazprom project in 1998, no projects have

  11. Design of a Slowed-Rotor Compound Helicopter for Future Joint Service Missions

    DTIC Science & Technology

    2010-01-01

    achieves a 208kt top speed at engine MCP and 11,000ft/ISA while having 216hp/ton installed power, based on engine MRP and MTOW. Figure 33...Intermediate rated power ISA International Standard Atmosphere MCP Maximum continuous power MRP Maximum rated power MTOW Maximum Takeoff Weight NDARC...NASA Design and Analysis of Rotorcraft SFC Specific fuel consumption SRC Slowed-Rotor Compound Symbols σ Rotor solidity (geometric) CD Drag

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Vleet, Mary J.; Misquitta, Alston J.; Stone, Anthony J.

    Short-range repulsion within inter-molecular force fields is conventionally described by either Lennard-Jones or Born-Mayer forms. Despite their widespread use, these simple functional forms are often unable to describe the interaction energy accurately over a broad range of inter-molecular distances, thus creating challenges in the development of ab initio force fields and potentially leading to decreased accuracy and transferability. Herein, we derive a novel short-range functional form based on a simple Slater-like model of overlapping atomic densities and an iterated stockholder atom (ISA) partitioning of the molecular electron density. We demonstrate that this Slater-ISA methodology yields a more accurate, transferable, andmore » robust description of the short-range interactions at minimal additional computational cost compared to standard Lennard-Jones or Born-Mayer approaches. Lastly, we show how this methodology can be adapted to yield the standard Born-Mayer functional form while still retaining many of the advantages of the Slater-ISA approach.« less

  13. Unaligned instruction relocation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertolli, Carlo; O'Brien, John K.; Sallenave, Olivier H.

    In one embodiment, a computer-implemented method includes receiving source code to be compiled into an executable file for an unaligned instruction set architecture (ISA). Aligned assembled code is generated, by a computer processor. The aligned assembled code complies with an aligned ISA and includes aligned processor code for a processor and aligned accelerator code for an accelerator. A first linking pass is performed on the aligned assembled code, including relocating a first relocation target in the aligned accelerator code that refers to a first object outside the aligned accelerator code. Unaligned assembled code is generated in accordance with the unalignedmore » ISA and includes unaligned accelerator code for the accelerator and unaligned processor code for the processor. A second linking pass is performed on the unaligned assembled code, including relocating a second relocation target outside the unaligned accelerator code that refers to an object in the unaligned accelerator code.« less

  14. OCO-2 Interstage Offload

    NASA Image and Video Library

    2014-02-10

    VANDENBERG AIR FORCE BASE, Calif. – The interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, arrives at the Building 836 hangar on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch aboard a United Launch Alliance Delta II rocket from Space Launch Complex 2 in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Jeremy Moore, 30th Space Wing, VAFB

  15. OCO-2 Interstage Offload

    NASA Image and Video Library

    2014-02-10

    VANDENBERG AIR FORCE BASE, Calif. – The high bay of the Building 836 hangar on Vandenberg Air Force Base in California is ready to receive the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2. OCO-2 is scheduled to launch aboard a United Launch Alliance Delta II rocket from Space Launch Complex 2 in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Jeremy Moore, 30th Space Wing, VAFB

  16. KSC-2014-2313

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – The interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, arrives at the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  17. KSC-2014-2316

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – Preparations are underway to lift the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, into the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  18. OCO-2 Interstage Offload

    NASA Image and Video Library

    2014-02-10

    VANDENBERG AIR FORCE BASE, Calif. – Workers attach the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, to a lifting device in the high bay of the Building 836 hangar on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch aboard a United Launch Alliance Delta II rocket from Space Launch Complex 2 in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Jeremy Moore, 30th Space Wing, VAFB

  19. Assessing institutional support for Hispanic nursing student retention: a study to evaluate the psychometric properties of two self-assessment inventories.

    PubMed

    Bond, Mary Lou; Cason, Carolyn L

    2014-01-01

    To assess the content validity and internal consistency reliability of the Healthcare Professions Education Program Self-Assessment (PSA) and the Institutional Self-Assessment for Factors Supporting Hispanic Student Retention (ISA). Health disparities among vulnerable populations are among the top priorities demanding attention in the United States. Efforts to recruit and retain Hispanic nursing students are essential. Based on a sample of provosts, deans/directors, and an author of the Model of Institutional Support, participants commented on the perceived validity and usefulness of each item of the PSA and ISA. Internal consistency reliability was calculated by Cronbach's alpha using responses from nursing schools in states with large Hispanic populations. The ISA and PSA were found to be reliable and valid tools for assessing institutional friendliness. The instruments highlight strengths and identify potential areas of improvement at institutional and program levels.

  20. Unaligned instruction relocation

    DOEpatents

    Bertolli, Carlo; O'Brien, John K.; Sallenave, Olivier H.; Sura, Zehra N.

    2018-01-23

    In one embodiment, a computer-implemented method includes receiving source code to be compiled into an executable file for an unaligned instruction set architecture (ISA). Aligned assembled code is generated, by a computer processor. The aligned assembled code complies with an aligned ISA and includes aligned processor code for a processor and aligned accelerator code for an accelerator. A first linking pass is performed on the aligned assembled code, including relocating a first relocation target in the aligned accelerator code that refers to a first object outside the aligned accelerator code. Unaligned assembled code is generated in accordance with the unaligned ISA and includes unaligned accelerator code for the accelerator and unaligned processor code for the processor. A second linking pass is performed on the unaligned assembled code, including relocating a second relocation target outside the unaligned accelerator code that refers to an object in the unaligned accelerator code.

  1. Vision-Aided Autonomous Precision Weapon Terminal Guidance Using a Tightly-Coupled INS and Predictive Rendering Techniques

    DTIC Science & Technology

    2011-03-01

    b b are additive accelerometer and gyro noises and w b abias and wbbbias are accelerometer bias and gyro bias noises. These will described in further...order accelerometer bias time constant and w b abias is the additive accelerometer bias noise, and ḃb = − 1 τb bb +wbbbias (2.43) where τb is the first

  2. Automatic machine-learning based identification of jogging periods from accelerometer measurements of adolescents under field conditions.

    PubMed

    Zdravevski, Eftim; Risteska Stojkoska, Biljana; Standl, Marie; Schulz, Holger

    2017-01-01

    Assessment of health benefits associated with physical activity depend on the activity duration, intensity and frequency, therefore their correct identification is very valuable and important in epidemiological and clinical studies. The aims of this study are: to develop an algorithm for automatic identification of intended jogging periods; and to assess whether the identification performance is improved when using two accelerometers at the hip and ankle, compared to when using only one at either position. The study used diarized jogging periods and the corresponding accelerometer data from thirty-nine, 15-year-old adolescents, collected under field conditions, as part of the GINIplus study. The data was obtained from two accelerometers placed at the hip and ankle. Automated feature engineering technique was performed to extract features from the raw accelerometer readings and to select a subset of the most significant features. Four machine learning algorithms were used for classification: Logistic regression, Support Vector Machines, Random Forest and Extremely Randomized Trees. Classification was performed using only data from the hip accelerometer, using only data from ankle accelerometer and using data from both accelerometers. The reported jogging periods were verified by visual inspection and used as golden standard. After the feature selection and tuning of the classification algorithms, all options provided a classification accuracy of at least 0.99, independent of the applied segmentation strategy with sliding windows of either 60s or 180s. The best matching ratio, i.e. the length of correctly identified jogging periods related to the total time including the missed ones, was up to 0.875. It could be additionally improved up to 0.967 by application of post-classification rules, which considered the duration of breaks and jogging periods. There was no obvious benefit of using two accelerometers, rather almost the same performance could be achieved from either accelerometer position. Machine learning techniques can be used for automatic activity recognition, as they provide very accurate activity recognition, significantly more accurate than when keeping a diary. Identification of jogging periods in adolescents can be performed using only one accelerometer. Performance-wise there is no significant benefit from using accelerometers on both locations.

  3. Using open source accelerometer analysis to assess physical activity and sedentary behaviour in overweight and obese adults.

    PubMed

    Innerd, Paul; Harrison, Rory; Coulson, Morc

    2018-04-23

    Physical activity and sedentary behaviour are difficult to assess in overweight and obese adults. However, the use of open-source, raw accelerometer data analysis could overcome this. This study compared raw accelerometer and questionnaire-assessed moderate-to-vigorous physical activity (MVPA), walking and sedentary behaviour in normal, overweight and obese adults, and determined the effect of using different methods to categorise overweight and obesity, namely body mass index (BMI), bioelectrical impedance analysis (BIA) and waist-to-hip ratio (WHR). One hundred twenty adults, aged 24-60 years, wore a raw, tri-axial accelerometer (Actigraph GT3X+), for 3 days and completed a physical activity questionnaire (IPAQ-S). We used open-source accelerometer analyses to estimate MVPA, walking and sedentary behaviour from a single raw accelerometer signal. Accelerometer and questionnaire-assessed measures were compared in normal, overweight and obese adults categorised using BMI, BIA and WHR. Relationships between accelerometer and questionnaire-assessed MVPA (Rs = 0.30 to 0.48) and walking (Rs = 0.43 to 0.58) were stronger in normal and overweight groups whilst sedentary behaviour were modest (Rs = 0.22 to 0.38) in normal, overweight and obese groups. The use of WHR resulted in stronger agreement between the questionnaire and accelerometer than BMI and BIA. Finally, accelerometer data showed stronger associations with BMI, BIA and WHR (Rs = 0.40 to 0.77) than questionnaire data (Rs = 0.24 to 0.37). Open-source, raw accelerometer data analysis can be used to estimate MVPA, walking and sedentary behaviour from a single acceleration signal in normal, overweight and obese adults. Our data supports the use of WHR to categorise overweight and obese adults. This evidence helps researchers obtain more accurate measures of physical activity and sedentary behaviour in overweight and obese populations.

  4. Comparison of self-reported versus accelerometer-measured physical activity.

    PubMed

    Dyrstad, Sindre M; Hansen, Bjørge H; Holme, Ingar M; Anderssen, Sigmund A

    2014-01-01

    The International Physical Activity Questionnaire (IPAQ) is one of the most widely used questionnaires to assess physical activity (PA). Validation studies for the IPAQ have been executed, but still there is a need for studies comparing absolute values between IPAQ and accelerometer in large population studies. To compare PA and sedentary time from the self-administered, short version of the IPAQ with data from ActiGraph accelerometer in a large national sample. A total of 1751 adults (19-84 yr) wore an accelerometer (ActiGraph GT1M) for seven consecutive days and completed the IPAQ-Short Form. Sedentary time, total PA, and time spent in moderate to vigorous activity were compared in relation to sex, age, and education. Men and women reported, on average, 131 min·d (SE = 4 min·d) less sedentary time compared with the accelerometer measurements. The difference between self-reported and measured sedentary time and vigorous-intensity PA was greatest among men with a lower education level and for men 65 yr and older. Although men reported 47% more moderate to vigorous physical activity (MVPA) compared with women, there were no differences between sexes in accelerometer-determined MVPA. Accelerometer-determined moderate PA was reduced from 110 to 42 min·d (62%) when analyzed in blocks of 10 min (P < 0.0001) compared with 1-min blocks. The main correlation coefficients between self-reported variables and accelerometer measures of physical activity were between 0.20 and 0.46. The participants report through IPAQ-Short Form more vigorous PA and less sedentary time compared with the accelerometer. The difference between self-reported and accelerometer-measured MVPA increased with higher activity and intensity levels. Associations between the methods were affected by sex, age, and education, but not body mass index.

  5. CpG Oligodeoxynucleotide and Montanide ISA 51 Adjuvant Combination Enhanced the Protective Efficacy of a Subunit Malaria Vaccine

    PubMed Central

    Kumar, Sanjai; Jones, Trevor R.; Oakley, Miranda S.; Zheng, Hong; Kuppusamy, Shanmuga P.; Taye, Alem; Krieg, Arthur M.; Stowers, Anthony W.; Kaslow, David C.; Hoffman, Stephen L.

    2004-01-01

    Unmethylated CpG dinucleotide motifs present in bacterial genomes or synthetic oligodeoxynucleotides (ODNs) serve as strong immunostimulatory agents in mice, monkeys and humans. We determined the adjuvant effect of murine CpG ODN 1826 on the immunogenicity and protective efficacy of the Saccharomyces cerevisiae-expressed 19-kDa C-terminal region of merozoite surface protein 1 (yMSP119) of the murine malaria parasite Plasmodium yoelii. We found that in C57BL/6 mice, following sporozoite challenge, the degree of protective immunity against malaria induced by yMSP119 in a formulation of Montanide ISA 51 (ISA) plus CpG ODN 1826 was similar or superior to that conferred by yMSP119 emulsified in complete Freund's adjuvant (CFA/incomplete Freund's adjuvant). In total, among mice immunized with yMSP119, 22 of 32 (68.7%) with ISA plus CpG 1826, 0 of 4 (0%) with CFA/incomplete Freund’s adjuvant, 0 of 4 (0%) with CpG 1826 mixed with ISA (no yMSP119), and 0 of 11 (0%) with CpG 1826 alone were completely protected against development of erythrocytic stage infection after sporozoite challenge. The adjuvant effect of CpG ODN 1826 was manifested as both significantly improved complete protection from malaria (defined as the absence of detectable erythrocytic form parasites) (P = 0.007, chi square) and reduced parasite burden in infected mice. In vivo depletions of interleukin-12 and gamma interferon cytokines and CD4+ and CD8+ T cells in vaccinated mice had no significant effect on immunity. On the other hand, immunoglobulin G (IgG) isotype levels appeared to correlate with protection. Inclusion of CpG ODN 1826 in the yMSP119 plus ISA vaccine contributed towards the induction of higher levels of IgG2a and IgG2b (Th1 type) antibodies, suggesting that CpG ODN 1826 caused a shift towards a Th1 type of immune response that could be responsible for the higher degree of protective immunity. Our results indicate that this potent adjuvant formulation should be further evaluated for use in clinical trials of recombinant malarial vaccine candidates. PMID:14742540

  6. Incorporation of DPP6a and DPP6K variants in ternary Kv4 channel complex reconstitutes properties of A-type K current in rat cerebellar granule cells.

    PubMed

    Jerng, Henry H; Pfaffinger, Paul J

    2012-01-01

    Dipeptidyl peptidase-like protein 6 (DPP6) proteins co-assemble with Kv4 channel α-subunits and Kv channel-interacting proteins (KChIPs) to form channel protein complexes underlying neuronal somatodendritic A-type potassium current (I(SA)). DPP6 proteins are expressed as N-terminal variants (DPP6a, DPP6K, DPP6S, DPP6L) that result from alternative mRNA initiation and exhibit overlapping expression patterns. Here, we study the role DPP6 variants play in shaping the functional properties of I(SA) found in cerebellar granule (CG) cells using quantitative RT-PCR and voltage-clamp recordings of whole-cell currents from reconstituted channel complexes and native I(SA) channels. Differential expression of DPP6 variants was detected in rat CG cells, with DPP6K (41 ± 3%)>DPP6a (33 ± 3%)>DPP6S (18 ± 2%)>DPP6L (8 ± 3%). To better understand how DPP6 variants shape native neuronal I(SA), we focused on studying interactions between the two dominant variants, DPP6K and DPP6a. Although previous studies did not identify unique functional effects of DPP6K, we find that the unique N-terminus of DPP6K modulates the effects of KChIP proteins, slowing recovery and producing a negative shift in the steady-state inactivation curve. By contrast, DPP6a uses its distinct N-terminus to directly confer rapid N-type inactivation independently of KChIP3a. When DPP6a and DPP6K are co-expressed in ratios similar to those found in CG cells, their distinct effects compete in modulating channel function. The more rapid inactivation from DPP6a dominates during strong depolarization; however, DPP6K produces a negative shift in the steady-state inactivation curve and introduces a slow phase of recovery from inactivation. A direct comparison to the native CG cell I(SA) shows that these mixed effects are present in the native channels. Our results support the hypothesis that the precise expression and co-assembly of different auxiliary subunit variants are important factors in shaping the I(SA) functional properties in specific neuronal populations.

  7. Wearable Accelerometers in High Performance Jet Aircraft.

    PubMed

    Rice, G Merrill; VanBrunt, Thomas B; Snider, Dallas H; Hoyt, Robert E

    2016-02-01

    Wearable accelerometers have become ubiquitous in the fields of exercise physiology and ambulatory hospital settings. However, these devices have yet to be validated in extreme operational environments. The objective of this study was to correlate the gravitational forces (G forces) detected by wearable accelerometers with the G forces detected by high performance aircraft. We compared the in-flight G forces detected by the two commercially available portable accelerometers to the F/A-18 Carrier Aircraft Inertial Navigation System (CAINS-2) during 20 flights performed by the Navy's Flight Demonstration Squadron (Blue Angels). Postflight questionnaires were also used to assess the perception of distractibility during flight. Of the 20 flights analyzed, 10 complete in-flight comparisons were made, accounting for 25,700 s of correlation between the CAINS-2 and the two tested accelerometers. Both accelerometers had strong correlations with that of the F/A-18 Gz axis, averaging r = 0.92 and r = 0.93, respectively, over 10 flights. Comparison of both portable accelerometer's average vector magnitude to each other yielded an average correlation of r = 0.93. Both accelerometers were found to be minimally distracting. These results suggest the use of wearable accelerometers is a valid means of detecting G forces during high performance aircraft flight. Future studies using this surrogate method of detecting accelerative forces combined with physiological information may yield valuable in-flight normative data that heretofore has been technically difficult to obtain and hence holds the promise of opening the door for a new golden age of aeromedical research.

  8. Antarctica: A Keystone in a Changing World--Online Proceedings for the Tenth International Symposium on Antarctic Earth Sciences. Santa Barbara, California, U.S.A.--August 26 to September 1, 2007

    USGS Publications Warehouse

    Cooper, Alan; Raymond, Carol; ,

    2007-01-01

    Overview: The International Symposium on Antarctic Earth Sciences (ISAES) is held once every four years to provide an international forum for presenting research results and new ideas and for planning future Antarctic geoscience research projects. This Tenth ISAES coincides with the International Polar Year (IPY; 50th Anniversary of the International Geophysical Year) and has been structured to showcase the great breadth of geoscience research being done in Antarctic regions by more than more than 100 institutions located in over 30 countries. The science program of the Symposium encompasses six broad themes that cover key topics on evolution and interactions of the geosphere, cryosphere and biosphere and their cross-linkages with past and historic paleoclimates. Emphasis is also on deciphering the climate records in ice cores, geologic cores, rock outcrops and those inferred from climate models. New technologies for the coming decades of geoscience data collection are also highlighted. Ten keynote presentations at the symposium outline the foundation for the research sessions of the symposium and the structure of the Online Proceedings and Proceedings Book for the Tenth ISAES. The ISAES is traditionally a cornerstone meeting for the Scientific Committee on Antarctic Research (SCAR). In recognition of the Tenth ISAES being held in the U.S. for the first time in 30 years and during IPY, the publication of the symposium proceedings is being handled as a special collaborative effort of the U.S. National Science Foundation, the U.S. Geological Survey, The National Academies Polar Research Board and The National Academies Press. The National Academies Polar Research Board oversees the activities of SCAR in the U.S. Special attention has been directed at publication formats for the symposium, to expedite the open and wide sharing of mature and preliminary research results presented in talks and posters at the Tenth ISAES. All symposium presentations are documented by a short Summary printed in the Symposium Program Booklet and either a short research paper or an extended abstract. The research papers and extended abstracts are compiled in this Online Proceedings and are replicated on a DVD-ROM that is placed in the back of the Tenth ISAES Proceedings Book. The Proceedings Book has printed versions of the keynote talks and an overview paper of the symposium. The short research papers and extended abstracts have been handled differently. Research papers present mature research results and syntheses. They have been peer-reviewed using standard journal procedures. Following revisions and acceptances by co-editors, the papers have been formatted for publication and proofread by authors. Each paper has been assigned a Digital Object Identification (DOI) number and separate html link, and posted online (as part of this USGS Open-File Report series) to ensure open and wide access to the research results. Extended abstracts focus on preliminary research results and have not been peer reviewed. They have had only minimal editorial review and revision. Authors have formatted and proofread their papers. Extended abstracts were not given DOI numbers and are included together in a separate chapter of this online Proceedings. USGS publications staff and Stanford-student editorial assistants indexed and compiled the PDF versions of the short research papers and extended abstracts for inclusion in this online Proceedings. USGS staff created the master DVD-ROM that contains a replica of the Online Proceedings for the Tenth ISAES, and provided the DVD-ROM copies that are included in the Tenth ISAES Proceedings Book published by The National Academies Press in the U.S. A team of more than 25 co-editors coordinated with the numerous authors and peer reviewers in handling the many research papers and extended abstracts that are included herein. Handling the large volume of short papers and extended abstracts, getting most of them onli

  9. Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013)

    DTIC Science & Technology

    2014-06-01

    Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013) by Andrew Drysdale...Proving Ground, MD 21005-5068 ARL-TR-6977 June 2014 Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results...4. TITLE AND SUBTITLE Low-Frequency Foam Insulator (LOFFI) Accelerometer Mount Characterization Results and Analysis for Phase I (FY2013) 5a

  10. Passivity-based sliding mode control for a polytopic stochastic differential inclusion system.

    PubMed

    Liu, Leipo; Fu, Zhumu; Song, Xiaona

    2013-11-01

    Passivity-based sliding mode control for a polytopic stochastic differential inclusion (PSDI) system is considered. A control law is designed such that the reachability of sliding motion is guaranteed. Moreover, sufficient conditions for mean square asymptotic stability and passivity of sliding mode dynamics are obtained by linear matrix inequalities (LMIs). Finally, two examples are given to illustrate the effectiveness of the proposed method. © 2013 ISA. Published by ISA. All rights reserved.

  11. Microbial degradation of isosaccharinic acid at high pH

    PubMed Central

    Bassil, Naji M; Bryan, Nicholas; Lloyd, Jonathan R

    2015-01-01

    Intermediate-level radioactive waste (ILW), which dominates the radioactive waste inventory in the United Kingdom on a volumetric basis, is proposed to be disposed of via a multibarrier deep geological disposal facility (GDF). ILW is a heterogeneous wasteform that contains substantial amounts of cellulosic material encased in concrete. Upon resaturation of the facility with groundwater, alkali conditions will dominate and will lead to the chemical degradation of cellulose, producing a substantial amount of organic co-contaminants, particularly isosaccharinic acid (ISA). ISA can form soluble complexes with radionuclides, thereby mobilising them and posing a potential threat to the surrounding environment or ‘far field'. Alkaliphilic microorganisms sampled from a legacy lime working site, which is an analogue for an ILW-GDF, were able to degrade ISA and couple this degradation to the reduction of electron acceptors that will dominate as the GDF progresses from an aerobic ‘open phase' through nitrate- and Fe(III)-reducing conditions post closure. Furthermore, pyrosequencing analyses showed that bacterial diversity declined as the reduction potential of the electron acceptor decreased and that more specialised organisms dominated under anaerobic conditions. These results imply that the microbial attenuation of ISA and comparable organic complexants, initially present or formed in situ, may play a role in reducing the mobility of radionuclides from an ILW-GDF, facilitating the reduction of undue pessimism in the long-term performance assessment of such facilities. PMID:25062127

  12. Structural health monitoring using a hybrid network of self-powered accelerometer and strain sensors

    NASA Astrophysics Data System (ADS)

    Alavi, Amir H.; Hasni, Hassene; Jiao, Pengcheng; Lajnef, Nizar

    2017-04-01

    This paper presents a structural damage identification approach based on the analysis of the data from a hybrid network of self-powered accelerometer and strain sensors. Numerical and experimental studies are conducted on a plate with bolted connections to verify the method. Piezoelectric ceramic Lead Zirconate Titanate (PZT)-5A ceramic discs and PZT-5H bimorph accelerometers are placed on the surface of the plate to measure the voltage changes due to damage progression. Damage is defined by loosening or removing one bolt at a time from the plate. The results show that the PZT accelerometers provide a fairly more consistent behavior than the PZT strain sensors. While some of the PZT strain sensors are not sensitive to the changes of the boundary condition, the bimorph accelerometers capture the mode changes from undamaged to missing bolt conditions. The results corresponding to the strain sensors are better indicator to the location of damage compared to the accelerometers. The characteristics of the overall structure can be monitored with even one accelerometer. On the other hand, several PZT strain sensors might be needed to localize the damage.

  13. Occupant Motion Sensors : Development and Testing of Piezoresistive Mouthpiece Rotational Accelerometer

    DOT National Transportation Integrated Search

    1973-07-01

    A miniature piezoresistive mouthpiece rotational accelerometer has been developed to measure the angular acceleration of a head during a simulated vehicle crash. Corrections have been electronically applied to the rotational accelerometer to reduce i...

  14. Ground Vibration Attenuation Measurement using Triaxial and Single Axis Accelerometers

    NASA Astrophysics Data System (ADS)

    Mohammad, A. H.; Yusoff, N. A.; Madun, A.; Tajudin, S. A. A.; Zahari, M. N. H.; Chik, T. N. T.; Rahman, N. A.; Annuar, Y. M. N.

    2018-04-01

    Peak Particle Velocity is one of the important term to show the level of the vibration amplitude especially traveling wave by distance. Vibration measurement using triaxial accelerometer is needed to obtain accurate value of PPV however limited by the size and the available channel of the data acquisition module for detailed measurement. In this paper, an attempt to estimate accurate PPV has been made by using only a triaxial accelerometer together with multiple single axis accelerometer for the ground vibration measurement. A field test was conducted on soft ground using nine single axis accelerometers and a triaxial accelerometer installed at nine receiver location R1 to R9. Based from the obtained result, the method shows convincing similarity between actual PPV with the calculated PPV with error ratio 0.97. With the design method, vibration measurement equipment size can be reduced with fewer channel required.

  15. Summary report of mission acceleration measurements for Spacehab-01, STS-57 launched 21 June 1993

    NASA Technical Reports Server (NTRS)

    Finley, Brian; Grodsinsky, Carlos; Delombard, Richard

    1994-01-01

    The maiden voyage of the commercial Spacehab laboratory module onboard the STS-57 mission was integrated with several accelerometer packages, one of which was the Space Acceleration Measurement System (SAMS). The June 21st 1993, launch was the seventh successful mission for the Office of Life and Microgravity Sciences and Application's (OLMSA) SAMS unit. This flight was also complemented by a second accelerometer system. The Three Dimensional Microgravity Accelerometer (3-DMA), a Code C funded acceleration measurement system, offering an on-orbit residual calibration as a reference for the unit's four triaxial accelerometers. The SAMS accelerometer unit utilized three remote triaxial sensor heads mounted on the forward Spacehab module bulkhead and on one centrally located experiment locker door. These triaxial heads had filter cut-offs set to 5, 50, and 1000 Hz. The mission also included other experiment specific accelerometer packages in various locations.

  16. Systems and Methods for Determining Inertial Navigation System Faults

    NASA Technical Reports Server (NTRS)

    Bharadwaj, Raj Mohan (Inventor); Bageshwar, Vibhor L. (Inventor); Kim, Kyusung (Inventor)

    2017-01-01

    An inertial navigation system (INS) includes a primary inertial navigation system (INS) unit configured to receive accelerometer measurements from an accelerometer and angular velocity measurements from a gyroscope. The primary INS unit is further configured to receive global navigation satellite system (GNSS) signals from a GNSS sensor and to determine a first set of kinematic state vectors based on the accelerometer measurements, the angular velocity measurements, and the GNSS signals. The INS further includes a secondary INS unit configured to receive the accelerometer measurements and the angular velocity measurements and to determine a second set of kinematic state vectors of the vehicle based on the accelerometer measurements and the angular velocity measurements. A health management system is configured to compare the first set of kinematic state vectors and the second set of kinematic state vectors to determine faults associated with the accelerometer or the gyroscope based on the comparison.

  17. Absolute marine gravimetry with matter-wave interferometry.

    PubMed

    Bidel, Y; Zahzam, N; Blanchard, C; Bonnin, A; Cadoret, M; Bresson, A; Rouxel, D; Lequentrec-Lalancette, M F

    2018-02-12

    Measuring gravity from an aircraft or a ship is essential in geodesy, geophysics, mineral and hydrocarbon exploration, and navigation. Today, only relative sensors are available for onboard gravimetry. This is a major drawback because of the calibration and drift estimation procedures which lead to important operational constraints. Atom interferometry is a promising technology to obtain onboard absolute gravimeter. But, despite high performances obtained in static condition, no precise measurements were reported in dynamic. Here, we present absolute gravity measurements from a ship with a sensor based on atom interferometry. Despite rough sea conditions, we obtained precision below 10 -5  m s -2 . The atom gravimeter was also compared with a commercial spring gravimeter and showed better performances. This demonstration opens the way to the next generation of inertial sensors (accelerometer, gyroscope) based on atom interferometry which should provide high-precision absolute measurements from a moving platform.

  18. Familiarizing Students with the Basics of a Smartphone's Internal Sensors

    NASA Astrophysics Data System (ADS)

    Countryman, Colleen Lanz

    2014-12-01

    The Physics Teacher's "iPhysicsLabs" column has been dedicated to the implementation of smartphones in instructional physics labs as data collection devices. In order to understand any data set, however, one should first understand how it is obtained. This concern regarding the inclusion of smartphones in lab activities has arisen in response to the creation of this column1 as well as to a paper in a recent issue of Physics Today.2 The majority of the labs featured in the "iPhysicsLabs" column to date make use of the internal accelerometer, common to nearly all smartphones on the market today. In order to glean meaningful conclusions from their data, students should first understand how the sensor works, as was pointed out in the first article to be featured in that column.3 We attempt to elucidate this "iBlackBox" using a simple ball-and-spring model.

  19. Epidemiological investigation into the re-emergence and control of an outbreak of infectious salmon anaemia in the Shetland Islands, Scotland.

    PubMed

    Murray, Alexander G; Munro, Lorna A; Wallace, I Stuart; Berx, Barbara; Pendrey, Daniel; Fraser, David; Raynard, Rob S

    2010-09-17

    Infectious salmon anaemia (ISA) is an orthomyxoviral disease, primarily affecting marine-phase farmed Atlantic salmon, which can result in high levels of mortality. ISA first emerged in Norway in the 1980s and subsequently has occurred in Canada, the USA, the Faeroe Islands and Chile. An outbreak occurred in Scotland in 1998-1999, but was eradicated at a cost of over pounds sterling 20M. The epidemiology of a new outbreak of ISA in the Scottish Shetland Islands during 2008-2009 is described. Six sites have been confirmed ISA-positive. Spread of the virus via transport of fish between marine sites, harvest vessels, smolts and wild fish appears to have been of little or no importance, with spread primarily associated with marine water currents. The use of management areas by Marine Scotland to control the event appears to have been effective in restricting spread to a small area. This localised outbreak contrasts with the 1998-1999 outbreak that spread over a wide geographic area with transported fish and harvest vessels. The development and application of industry codes of good practice, good husbandry and biosecurity practices, limited marine site-to-site movement of live fish and improved disinfection of vessels and processing plant waste that occurred subsequent to the 1998-1999 outbreak may explain the localised spread of infection in 2008-2009. Depopulation of confirmed sites has been achieved within 7 wk (mean = 3.7 wk); however, it is likely that subclinical infection persisted undetected for months on at least 1 site. The origin of the 2008-2009 outbreak remains unknown. Potential sources include evolution from a local reservoir of infection or importation. Synchronous fallowing of management areas, with good husbandry and biosecurity, reduces the risk of ISA recurring. Movement of fish between sites in different management areas represents the greatest risk of regional-scale spread, should this occur.

  20. Age-related changes in fear, sociality and pecking behaviours in two strains of laying hen.

    PubMed

    Hocking, P M; Channing, C E; Waddington, D; Jones, R B

    2001-09-01

    1. Two lines of commercial hybrid layers (Tetra and ISA Brown) were reared from hatch to 30 weeks of age in groups of 8. The objectives of the experiment were to evaluate the significance of the different selection practices involved in the development of the lines and to assess the potential association between selected behavioural states and the potential for feather damage and cannibalism. 2. Behavioural tests related to fear (tonic immobility, novel object, open field), sociality (runway, proximity in the home pen) and pecking (feather bunch and focal observations of inter-bird and environmental pecking) were conducted at 0 to 2, 5 to 7, 12 to 14, 19 to 21 and 29 to 31 weeks of age. Scan sampling of general behaviour was also conducted at these ages. 3. Underlying sociality was greater in Tetras than in ISA Brown hens. 4. There were no apparent overall strain differences in fearfulness although ISA Brown hens showed significantly longer tonic immobility fear reactions than Tetras at 31 weeks of age. 5. ISA Brown hens gave and received more gentle pecks than Tetra hens whereas preening was commoner among Tetras. There were no strain differences in the number of pecks at litter or food. 6. As birds aged they showed less avoidance of novel objects and Tetras, though not ISA Browns, showed progressively shorter tonic immobility responses. Birds of both strains spent less time resting, more foraging (pecking and scratching) and pecked more at the feather bunch at older ages. 7. Measures taken in the TI, open field, runway (social affiliation) and feather bunch tests were stable over time whereas focal observations of pecking at hens and the environment were not. 8. Factor Analysis showed that 3 factors defined by the novel object test, environmental pecking and pecking ata feather bunch explained most of the variation in the correlation matrix between summary measures for the 8 behavioural traits.

  1. Effect of beta blockade with and without sympathomimetic activity (ISA) on sympathovagal balance and baroreflex sensitivity.

    PubMed

    Haberthür, C; Schächinger, H; Langewitz, W; Ritz, R

    1999-03-01

    Beta blockers increase heart rate variability (HRV) and improve survival in coronary artery disease (CAD). The benefit of beta blockers with intrinsic sympathomimetic activity (ISA) in CAD still remains a matter of debate, and their effect on HRV has not yet been investigated. Therefore, we measured HRV, systolic blood pressure variability (BPV) and baroreflex sensitivity (BRS) under propranolol (PROP, without ISA, 160 mg q.d.), pindolol (PIN, with potent ISA, 15 mg q.d.) and placebo (PLA, q.d.) in 30 healthy subjects, aged 21-39 years, during controlled frequency breathing (0.30 Hz) in supine and tilt positions. PROP increased HRV in the high-frequency (0.15-0.40 Hz) band (PROP 7.4 +/- 1.0; PLA 6.9 +/- 1.4; PIN 6.8 +/- 1.0 ln MI2; P = 0.003), decreased BPV in the low-frequency band (at 0.1 Hz, Mayer waves) (PROP 0.6 +/- 0.7; PLA 1.3 +/- 1.1; PIN 1.2 +/- 1.2 ln mmHg2; P = 0.001) and enhanced BRS (PROP 14.6 +/- 9.5; PLA 8.0 +/- 6.8; PIN 8.7 +/- 6.8 ms mmHg-1; P = 0.001) in the supine position. After passive tilt, PROP decreased HRV in the low-frequency band (PROP 6.1 +/- 0.9; PLA 6.5 +/- 1.1; PIN 6.9 +/- 0.7 ln MI2; P < 0.001) and decreased Mayer waves (PROP 1.8 +/- 0.8; PLA 2.4 +/- 1.0; PIN 2.7 +/- 0.8 ln mm Hg2; P < 0.001). PIN increased the low-frequency HRV response, which is induced by passive tilt (PIN + 0.9 +/- 1.0; PLA + 0.3 +/- 1.3, PROP + 0.3 +/- 1.0 ln MI2; P = 0.026). Our results prove that beta-adrenergic blockade with potent ISA does not increase HRV, has no beneficial effect on autonomic balance and even exaggerates sympathetic responses to passive tilt.

  2. Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women.

    PubMed

    Kinnunen, Tarja I; Tennant, Peter W G; McParlin, Catherine; Poston, Lucilla; Robson, Stephen C; Bell, Ruth

    2011-06-27

    Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Pregnant women (n = 58) with body mass index ≥25 kg/m(2) at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women.

  3. Display-And-Alarm Circuit For Accelerometer

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr.

    1995-01-01

    Compact accelerometer assembly consists of commercial accelerometer retrofit with display-and-alarm circuit. Provides simple means for technician attending machine to monitor vibrations. Also simpifies automatic safety shutdown by providing local alarm or shutdown signal when vibration exceeds preset level.

  4. Automatic machine-learning based identification of jogging periods from accelerometer measurements of adolescents under field conditions

    PubMed Central

    Risteska Stojkoska, Biljana; Standl, Marie; Schulz, Holger

    2017-01-01

    Background Assessment of health benefits associated with physical activity depend on the activity duration, intensity and frequency, therefore their correct identification is very valuable and important in epidemiological and clinical studies. The aims of this study are: to develop an algorithm for automatic identification of intended jogging periods; and to assess whether the identification performance is improved when using two accelerometers at the hip and ankle, compared to when using only one at either position. Methods The study used diarized jogging periods and the corresponding accelerometer data from thirty-nine, 15-year-old adolescents, collected under field conditions, as part of the GINIplus study. The data was obtained from two accelerometers placed at the hip and ankle. Automated feature engineering technique was performed to extract features from the raw accelerometer readings and to select a subset of the most significant features. Four machine learning algorithms were used for classification: Logistic regression, Support Vector Machines, Random Forest and Extremely Randomized Trees. Classification was performed using only data from the hip accelerometer, using only data from ankle accelerometer and using data from both accelerometers. Results The reported jogging periods were verified by visual inspection and used as golden standard. After the feature selection and tuning of the classification algorithms, all options provided a classification accuracy of at least 0.99, independent of the applied segmentation strategy with sliding windows of either 60s or 180s. The best matching ratio, i.e. the length of correctly identified jogging periods related to the total time including the missed ones, was up to 0.875. It could be additionally improved up to 0.967 by application of post-classification rules, which considered the duration of breaks and jogging periods. There was no obvious benefit of using two accelerometers, rather almost the same performance could be achieved from either accelerometer position. Conclusions Machine learning techniques can be used for automatic activity recognition, as they provide very accurate activity recognition, significantly more accurate than when keeping a diary. Identification of jogging periods in adolescents can be performed using only one accelerometer. Performance-wise there is no significant benefit from using accelerometers on both locations. PMID:28880923

  5. Comparison of linear and non-linear models for predicting energy expenditure from raw accelerometer data.

    PubMed

    Montoye, Alexander H K; Begum, Munni; Henning, Zachary; Pfeiffer, Karin A

    2017-02-01

    This study had three purposes, all related to evaluating energy expenditure (EE) prediction accuracy from body-worn accelerometers: (1) compare linear regression to linear mixed models, (2) compare linear models to artificial neural network models, and (3) compare accuracy of accelerometers placed on the hip, thigh, and wrists. Forty individuals performed 13 activities in a 90 min semi-structured, laboratory-based protocol. Participants wore accelerometers on the right hip, right thigh, and both wrists and a portable metabolic analyzer (EE criterion). Four EE prediction models were developed for each accelerometer: linear regression, linear mixed, and two ANN models. EE prediction accuracy was assessed using correlations, root mean square error (RMSE), and bias and was compared across models and accelerometers using repeated-measures analysis of variance. For all accelerometer placements, there were no significant differences for correlations or RMSE between linear regression and linear mixed models (correlations: r  =  0.71-0.88, RMSE: 1.11-1.61 METs; p  >  0.05). For the thigh-worn accelerometer, there were no differences in correlations or RMSE between linear and ANN models (ANN-correlations: r  =  0.89, RMSE: 1.07-1.08 METs. Linear models-correlations: r  =  0.88, RMSE: 1.10-1.11 METs; p  >  0.05). Conversely, one ANN had higher correlations and lower RMSE than both linear models for the hip (ANN-correlation: r  =  0.88, RMSE: 1.12 METs. Linear models-correlations: r  =  0.86, RMSE: 1.18-1.19 METs; p  <  0.05), and both ANNs had higher correlations and lower RMSE than both linear models for the wrist-worn accelerometers (ANN-correlations: r  =  0.82-0.84, RMSE: 1.26-1.32 METs. Linear models-correlations: r  =  0.71-0.73, RMSE: 1.55-1.61 METs; p  <  0.01). For studies using wrist-worn accelerometers, machine learning models offer a significant improvement in EE prediction accuracy over linear models. Conversely, linear models showed similar EE prediction accuracy to machine learning models for hip- and thigh-worn accelerometers and may be viable alternative modeling techniques for EE prediction for hip- or thigh-worn accelerometers.

  6. System Wide Joint Position Sensor Fault Tolerance in Robot Systems Using Cartesian Accelerometers

    NASA Technical Reports Server (NTRS)

    Aldridge, Hal A.; Juang, Jer-Nan

    1997-01-01

    Joint position sensors are necessary for most robot control systems. A single position sensor failure in a normal robot system can greatly degrade performance. This paper presents a method to obtain position information from Cartesian accelerometers without integration. Depending on the number and location of the accelerometers. the proposed system can tolerate the loss of multiple position sensors. A solution technique suitable for real-time implementation is presented. Simulations were conducted using 5 triaxial accelerometers to recover from the loss of up to 4 joint position sensors on a 7 degree of freedom robot moving in general three dimensional space. The simulations show good estimation performance using non-ideal accelerometer measurements.

  7. ISA software suite: supporting standards-compliant experimental annotation and enabling curation at the community level

    PubMed Central

    Rocca-Serra, Philippe; Brandizi, Marco; Maguire, Eamonn; Sklyar, Nataliya; Taylor, Chris; Begley, Kimberly; Field, Dawn; Harris, Stephen; Hide, Winston; Hofmann, Oliver; Neumann, Steffen; Sterk, Peter; Tong, Weida; Sansone, Susanna-Assunta

    2010-01-01

    Summary: The first open source software suite for experimentalists and curators that (i) assists in the annotation and local management of experimental metadata from high-throughput studies employing one or a combination of omics and other technologies; (ii) empowers users to uptake community-defined checklists and ontologies; and (iii) facilitates submission to international public repositories. Availability and Implementation: Software, documentation, case studies and implementations at http://www.isa-tools.org Contact: isatools@googlegroups.com PMID:20679334

  8. Recommended Methodology for Inter-Service/Agency Automated Message Processing Exchange (I-S/A AMPE). Cost and Schedule Analysis of Security Alternatives.

    DTIC Science & Technology

    1982-02-23

    segregate the computer and storage from the outside world 2. Administrative security to control access to secure computer facilities 3. Network security to...Classification Alternative A- 8 NETWORK KG GENSER DSSCS AMPE TERMINALS TP No. 022-4668-A Figure A-2. Dedicated Switching Architecture Alternative A- 9...communications protocol with the network and GENSER message transmission to the - I-S/A AMPE processor. 7. DSSCS TPU - Handles communications protocol with

  9. A low-noise MEMS accelerometer for unattended ground sensor applications

    NASA Astrophysics Data System (ADS)

    Speller, Kevin E.; Yu, Duli

    2004-09-01

    A low-noise micro-machined servo accelerometer has been developed for use in Unattended Ground Sensors (UGS). Compared to conventional coil-and-magnet based velocity transducers, this Micro-Electro-Mechanical System (MEMS) accelerometer offers several key benefits for battlefield monitoring. Many UGS require a compass to determine deployment orientation with respect to magnetic North. This orientation information is critical for determining the bearing of incoming signals. Conventional sensors with sensing technology based on a permanent magnet can cause interference with a compass when used in close proximity. This problem is solved with a MEMS accelerometer which does not require any magnetic materials. Frequency information below 10 Hz is valuable for identification of signal sources. Conventional seismometers used in UGS are typically limited in frequency response from 20 to 200 Hz. The MEMS accelerometer has a flat frequency response from DC to 5 kHz. The wider spectrum of signals received improves detection, classification and monitoring on the battlefield. The DC-coupled output of the MEMS accelerometer also has the added benefit of providing tilt orientation data for the deployed UGS. Other performance parameters of the MEMS accelerometer that are important to UGS such as size, weight, shock survivability, phase response, distortion, and cross-axis rejection will be discussed. Additionally, field test data from human footsteps recorded with the MEMS accelerometer will be presented.

  10. Design of a sample acquistion system for the Mars exobiological penetrator

    NASA Technical Reports Server (NTRS)

    Thomson, Ron; Gwynne, Owen

    1988-01-01

    The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

  11. Assessing Stride Variables and Vertical Stiffness with GPS-Embedded Accelerometers: Preliminary Insights for the Monitoring of Neuromuscular Fatigue on the Field

    PubMed Central

    Buchheit, Martin; Gray, Andrew; Morin, Jean-Benoit

    2015-01-01

    The aim of the present study was to examine the ability of a GPS-imbedded accelerometer to assess stride variables and vertical stiffness (K), which are directly related to neuromuscular fatigue during field-based high-intensity runs. The ability to detect stride imbalances was also examined. A team sport player performed a series of 30-s runs on an instrumented treadmill (6 runs at 10, 17 and 24 km·h-1) with or without his right ankle taped (aimed at creating a stride imbalance), while wearing on his back a commercially-available GPS unit with an embedded 100-Hz tri-axial accelerometer. Contact (CT) and flying (FT) time, and K were computed from both treadmill and accelerometers (Athletic Data Innovations) data. The agreement between treadmill (criterion measure) and accelerometer-derived data was examined. We also compared the ability of the different systems to detect the stride imbalance. Biases were small (CT and K) and moderate (FT). The typical error of the estimate was trivial (CT), small (K) and moderate (FT), with nearly perfect (CT and K) and large (FT) correlations for treadmill vs. accelerometer. The tape induced very large increase in the right - left foot ∆ in CT, FT and K measured by the treadmill. The tape effect on CT and K ∆ measured with the accelerometers were also very large, but of lower magnitude than with the treadmill. The tape effect on accelerometer-derived ∆ FT was unclear. Present data highlight the potential of a GPS-embedded accelerometer to assess CT and K during ground running. Key points GPS-embedded tri-axial accelerometers may be used to assess contact time and vertical stiffness during ground running. These preliminary results open new perspective for the field monitoring of neuromuscular fatigue and performance in run-based sports PMID:26664264

  12. Implementation of accelerometer sensor module and fall detection monitoring system based on wireless sensor network.

    PubMed

    Lee, Youngbum; Kim, Jinkwon; Son, Muntak; Lee, Myoungho

    2007-01-01

    This research implements wireless accelerometer sensor module and algorithm to determine wearer's posture, activity and fall. Wireless accelerometer sensor module uses ADXL202, 2-axis accelerometer sensor (Analog Device). And using wireless RF module, this module measures accelerometer signal and shows the signal at ;Acceloger' viewer program in PC. ADL algorithm determines posture, activity and fall that activity is determined by AC component of accelerometer signal and posture is determined by DC component of accelerometer signal. Those activity and posture include standing, sitting, lying, walking, running, etc. By the experiment for 30 subjects, the performance of implemented algorithm was assessed, and detection rate for postures, motions and subjects was calculated. Lastly, using wireless sensor network in experimental space, subject's postures, motions and fall monitoring system was implemented. By the simulation experiment for 30 subjects, 4 kinds of activity, 3 times, fall detection rate was calculated. In conclusion, this system can be application to patients and elders for activity monitoring and fall detection and also sports athletes' exercise measurement and pattern analysis. And it can be expected to common person's exercise training and just plaything for entertainment.

  13. Drift Mode Accelerometry for Spaceborne Gravity Measurements

    NASA Astrophysics Data System (ADS)

    Conklin, J. W.; Shelley, R.; Chilton, A.; Olatunde, T.; Ciani, G.; Mueller, G.

    2014-12-01

    A drift mode accelerometer is a precision instrument for spacecraft that overcomes much of the acceleration noise and readout dynamic range limitations of traditional electrostatic accelerometers. It has the potential of achieving acceleration noise performance similar to that of drag-free systems over a restricted frequency band without the need for external drag-free control or continuous spacecraft propulsion. Like traditional accelerometers, the drift mode accelerometer contains a high-density test mass surrounded by an electrode housing, which can control and sense all six degrees of freedom of the test mass. Unlike traditional accelerometers, the suspension system is operated with a low duty cycle so that the limiting suspension force noise only acts over brief, known time intervals, which can be accounted for in the data analysis. The readout is performed using a laser interferometer which is immune to the dynamic range limitations of even the best voltage references typically used to determine the inertial acceleration of electrostatic accelerometers. This presentation describes operation and performance modeling for such a device with respect to a low Earth orbiting satellite geodesy mission. Methods for testing the drift mode accelerometer with the University of Florida precision torsion pendulum will also be discussed.

  14. A methodology to leverage cross-sectional accelerometry to capture weather's influence in active living research.

    PubMed

    Katapally, Tarun R; Rainham, Daniel; Muhajarine, Nazeem

    2016-06-27

    While active living interventions focus on modifying urban design and built environment, weather variation, a phenomenon that perennially interacts with these environmental factors, is consistently underexplored. This study's objective is to develop a methodology to link weather data with existing cross-sectional accelerometry data in capturing weather variation. Saskatoon's neighbourhoods were classified into grid-pattern, fractured grid-pattern and curvilinear neighbourhoods. Thereafter, 137 Actical accelerometers were used to derive moderate to vigorous physical activity (MVPA) and sedentary behaviour (SB) data from 455 children in 25 sequential one-week cycles between April and June, 2010. This sequential deployment was necessary to overcome the difference in the ratio between the sample size and the number of accelerometers. A data linkage methodology was developed, where each accelerometry cycle was matched with localized (Saskatoon-specific) weather patterns derived from Environment Canada. Statistical analyses were conducted to depict the influence of urban design on MVPA and SB after factoring in localized weather patterns. Integration of cross-sectional accelerometry with localized weather patterns allowed the capture of weather variation during a single seasonal transition. Overall, during the transition from spring to summer in Saskatoon, MVPA increased and SB decreased during warmer days. After factoring in localized weather, a recurring observation was that children residing in fractured grid-pattern neighbourhoods accumulated significantly lower MVPA and higher SB. The proposed methodology could be utilized to link globally available cross-sectional accelerometry data with place-specific weather data to understand how built and social environmental factors interact with varying weather patterns in influencing active living.

  15. Measurement of the Earth tides with a MEMS gravimeter.

    PubMed

    Middlemiss, R P; Samarelli, A; Paul, D J; Hough, J; Rowan, S; Hammond, G D

    2016-03-31

    The ability to measure tiny variations in the local gravitational acceleration allows, besides other applications, the detection of hidden hydrocarbon reserves, magma build-up before volcanic eruptions, and subterranean tunnels. Several technologies are available that achieve the sensitivities required for such applications (tens of microgal per hertz(1/2)): free-fall gravimeters, spring-based gravimeters, superconducting gravimeters, and atom interferometers. All of these devices can observe the Earth tides: the elastic deformation of the Earth's crust as a result of tidal forces. This is a universally predictable gravitational signal that requires both high sensitivity and high stability over timescales of several days to measure. All present gravimeters, however, have limitations of high cost (more than 100,000 US dollars) and high mass (more than 8 kilograms). Here we present a microelectromechanical system (MEMS) device with a sensitivity of 40 microgal per hertz(1/2) only a few cubic centimetres in size. We use it to measure the Earth tides, revealing the long-term stability of our instrument compared to any other MEMS device. MEMS accelerometers--found in most smart phones--can be mass-produced remarkably cheaply, but none are stable enough to be called a gravimeter. Our device has thus made the transition from accelerometer to gravimeter. The small size and low cost of this MEMS gravimeter suggests many applications in gravity mapping. For example, it could be mounted on a drone instead of low-flying aircraft for distributed land surveying and exploration, deployed to monitor volcanoes, or built into multi-pixel density-contrast imaging arrays.

  16. Can mobile phones used in strong motion seismology?

    NASA Astrophysics Data System (ADS)

    D'Alessandro, Antonino; D'Anna, Giuseppe

    2013-04-01

    Micro Electro-Mechanical Systems (MEMS) accelerometers are electromechanical devices able to measure static or dynamic accelerations. In the 1990s MEMS accelerometers revolutionized the automotive-airbag system industry and are currently widely used in laptops, game controllers and mobile phones. Nowadays MEMS accelerometers seems provide adequate sensitivity, noise level and dynamic range to be applicable to earthquake strong motion acquisition. The current use of 3 axes MEMS accelerometers in mobile phone maybe provide a new means to easy increase the number of observations when a strong earthquake occurs. However, before utilize the signals recorded by a mobile phone equipped with a 3 axes MEMS accelerometer for any scientific porpoise, it is fundamental to verify that the signal collected provide reliable records of ground motion. For this reason we have investigated the suitability of the iPhone 5 mobile phone (one of the most popular mobile phone in the world) for strong motion acquisition. It is provided by several MEMS devise like a three-axis gyroscope, a three-axis electronic compass and a the LIS331DLH three-axis accelerometer. The LIS331DLH sensor is a low-cost high performance three axes linear accelerometer, with 16 bit digital output, produced by STMicroelectronics Inc. We have tested the LIS331DLH MEMS accelerometer using a vibrating table and the EpiSensor FBA ES-T as reference sensor. In our experiments the reference sensor was rigidly co-mounted with the LIS331DHL MEMS sensor on the vibrating table. We assessment the MEMS accelerometer in the frequency range 0.2-20 Hz, typical range of interesting in strong motion seismology and earthquake engineering. We generate both constant and damped sine waves with central frequency starting from 0.2 Hz until 20 Hz with step of 0.2 Hz. For each frequency analyzed we generate sine waves with mean amplitude 50, 100, 200, 400, 800 and 1600 mg0. For damped sine waves we generate waveforms with initial amplitude of 2 g0. Our tests show as, in the frequency and amplitude range analyzed (0.2-20 Hz, 10-2000 mg0), the LIS331DLH MEMS accelerometer have excellent frequency and phase response, comparable with that of some standard FBA accelerometer used in strong motion seismology. However, we found that the signal recorded by the LIS331DLH MEMS accelerometer slightly underestimates the real acceleration (of about 2.5%). This suggests that may be important to calibrate a MEMS sensor before using it in scientific applications. A drawback of the LIS331DLH MEMS accelerometer is its low sensitivity. This is an important limitation of all the low cost MEMS accelerometers; therefore nowadays they are desirable to use only in strong motion seismology. However, the rapid development of this technology will lead in the coming years to the development of high sensitivity and low noise digital MEMS sensors that may be replace the current seismic accelerometer used in seismology. Actually, the real main advantage of these sensors is their common use in the mobile phones.

  17. Rectilinear accelerometer possesses self- calibration feature

    NASA Technical Reports Server (NTRS)

    Henderson, R. B.

    1966-01-01

    Rectilinear accelerometer operates from an ac source with a phase-sensitive ac voltage output proportional to the applied accelerations. The unit includes an independent circuit for self-test which provides a sensor output simulating an acceleration applied to the sensitive axis of the accelerometer.

  18. Enhancing the growth, photosynthetic capacity and artemisinin content in Artemisia annua L. by irradiated sodium alginate

    NASA Astrophysics Data System (ADS)

    Aftab, Tariq; Khan, M. Masroor A.; Idrees, M.; Naeem, M.; Moinuddin; Hashmi, Nadeem; Varshney, Lalit

    2011-07-01

    Degrading the natural bioactive agents by ionizing radiation and then using them as growth promoting substances is a novel emerging technology to exploit the genetic potential of crops in terms of growth, yield and quality. Polysaccharides, such as sodium alginate, have proven to be wonderful growth promoting substances in their depolymerized form for various plants. The effect of depolymerized form of sodium alginate, produced by irradiating the latter by 60Co gamma rays, was studied on Artemisia annua L. with regard to growth attributes, physiological and biochemical parameters and artemisinin content. The study revealed that the irradiated sodium alginate (ISA), applied as leaf-sprays at a concentration of 20-120 mg L -1, improved the growth attributes, photosynthetic capability, enzyme activities and artemisinin content of the plant significantly. Application of ISA at 80 mg L -1 increased the values of the attributes studied to the maximum extent. The enhancement of leaf-artemisinin content was ascribed to the ISA-enhanced H 2O 2 content in the leaves.

  19. Beyond Born-Mayer: Improved models for short-range repulsion in ab initio force fields

    DOE PAGES

    Van Vleet, Mary J.; Misquitta, Alston J.; Stone, Anthony J.; ...

    2016-06-23

    Short-range repulsion within inter-molecular force fields is conventionally described by either Lennard-Jones or Born-Mayer forms. Despite their widespread use, these simple functional forms are often unable to describe the interaction energy accurately over a broad range of inter-molecular distances, thus creating challenges in the development of ab initio force fields and potentially leading to decreased accuracy and transferability. Herein, we derive a novel short-range functional form based on a simple Slater-like model of overlapping atomic densities and an iterated stockholder atom (ISA) partitioning of the molecular electron density. We demonstrate that this Slater-ISA methodology yields a more accurate, transferable, andmore » robust description of the short-range interactions at minimal additional computational cost compared to standard Lennard-Jones or Born-Mayer approaches. Lastly, we show how this methodology can be adapted to yield the standard Born-Mayer functional form while still retaining many of the advantages of the Slater-ISA approach.« less

  20. KSC-2014-2320

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – The interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, glides up the side of the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California, tethered to a crane. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  1. KSC-2014-2322

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – The interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, arrives in the environmental enclosure, or clean room, near the top of the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  2. KSC-2014-2315

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – A worker connects a crane to the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, at the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  3. KSC-2014-2317

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – Workers prepare to lift the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, by crane into the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  4. KSC-2014-2314

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – A worker prepares to connect a crane to the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, at the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  5. KSC-2014-2323

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – A worker steadies the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, upon its arrival in the environmental enclosure, or clean room, near the top of the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  6. KSC-2014-2319

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – A crane lifts the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, up the side of the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  7. KSC-2014-2326

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – The interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, is connected to the Delta II first stage in the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California and ready for delivery of the rocket's second stage. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  8. KSC-2014-2318

    NASA Image and Video Library

    2014-04-07

    VANDENBERG AIR FORCE BASE, Calif. – Workers steady the interstage adapter, or ISA, for NASA's Orbiting Carbon Observatory-2 mission, or OCO-2, as a crane lifts it from its transporter next to the mobile service tower at Space Launch Complex 2 on Vandenberg Air Force Base in California. OCO-2 is scheduled to launch into a polar Earth orbit aboard a United Launch Alliance Delta II 7320-10C rocket in July. The ISA is the interface between the Delta II first and second stages. The second stage engine fits within the ISA. Once in orbit, OCO-2 will collect precise global measurements of carbon dioxide in the Earth's atmosphere and provide scientists with a better idea of the chemical compound's impacts on climate change. Scientists will analyze this data to improve our understanding of the natural processes and human activities that regulate the abundance and distribution of this important atmospheric gas. To learn more about OCO-2, visit http://oco.jpl.nasa.gov. Photo credit: NASA/Randy Beaudoin

  9. Agreement between pedometer and accelerometer in measuring physical activity in overweight and obese pregnant women

    PubMed Central

    2011-01-01

    Background Inexpensive, reliable objective methods are needed to measure physical activity (PA) in large scale trials. This study compared the number of pedometer step counts with accelerometer data in pregnant women in free-living conditions to assess agreement between these measures. Methods Pregnant women (n = 58) with body mass index ≥25 kg/m2 at median 13 weeks' gestation wore a GT1M Actigraph accelerometer and a Yamax Digi-Walker CW-701 pedometer for four consecutive days. The Spearman rank correlation coefficients were determined between pedometer step counts and various accelerometer measures of PA. Total agreement between accelerometer and pedometer step counts was evaluated by determining the 95% limits of agreement estimated using a regression-based method. Agreement between the monitors in categorising participants as active or inactive was assessed by determining Kappa. Results Pedometer step counts correlated moderately (r = 0.36 to 0.54) with most accelerometer measures of PA. Overall step counts recorded by the pedometer and the accelerometer were not significantly different (medians 5961 vs. 5687 steps/day, p = 0.37). However, the 95% limits of agreement ranged from -2690 to 2656 steps/day for the mean step count value (6026 steps/day) and changed substantially over the range of values. Agreement between the monitors in categorising participants to active and inactive varied from moderate to good depending on the criteria adopted. Conclusions Despite statistically significant correlations and similar median step counts, the overall agreement between pedometer and accelerometer step counts was poor and varied with activity level. Pedometer and accelerometer steps cannot be used interchangeably in overweight and obese pregnant women. PMID:21703033

  10. Accelerometer thresholds: Accounting for body mass reduces discrepancies between measures of physical activity for individuals with overweight and obesity.

    PubMed

    Raiber, Lilian; Christensen, Rebecca A G; Jamnik, Veronica K; Kuk, Jennifer L

    2017-01-01

    The objective of this study was to explore whether accelerometer thresholds that are adjusted to account for differences in body mass influence discrepancies between self-report and accelerometer-measured physical activity (PA) volume for individuals with overweight and obesity. We analyzed 6164 adults from the National Health and Nutrition Examination Survey between 2003-2006. Established accelerometer thresholds were adjusted to account for differences in body mass to produce a similar energy expenditure (EE) rate as individuals with normal weight. Moderate-, vigorous-, and moderate- to vigorous-intensity PA (MVPA) durations were measured using established and adjusted accelerometer thresholds and compared with self-report. Durations of self-report were longer than accelerometer-measured MVPA using established thresholds (normal weight: 57.8 ± 2.4 vs 9.0 ± 0.5 min/day, overweight: 56.1 ± 2.7 vs 7.4 ± 0.5 min/day, and obesity: 46.5 ± 2.2 vs 3.7 ± 0.3 min/day). Durations of subjective and objective PA were negatively associated with body mass index (BMI) (P < 0.05). Using adjusted thresholds increased MVPA durations, and reduced discrepancies between accelerometer and self-report measures for overweight and obese groups by 6.0 ± 0.3 min/day and 17.7 ± 0.8 min/day, respectively (P < 0.05). Using accelerometer thresholds that represent equal EE rates across BMI categories reduced the discrepancies between durations of subjective and objective PA for overweight and obese groups. However, accelerometer-measured PA generally remained shorter than durations of self-report within all BMI categories. Further research may be necessary to improve analytical approaches when using objective measures of PA for individuals with overweight or obesity.

  11. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time

    PubMed Central

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-01

    Objectives To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. Methods 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1–4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Results Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to −139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. Conclusions This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. PMID:28093433

  12. Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification.

    PubMed

    Ellis, Katherine; Kerr, Jacqueline; Godbole, Suneeta; Staudenmayer, John; Lanckriet, Gert

    2016-05-01

    Accelerometers are a valuable tool for objective measurement of physical activity (PA). Wrist-worn devices may improve compliance over standard hip placement, but more research is needed to evaluate their validity for measuring PA in free-living settings. Traditional cut-point methods for accelerometers can be inaccurate and need testing in free living with wrist-worn devices. In this study, we developed and tested the performance of machine learning (ML) algorithms for classifying PA types from both hip and wrist accelerometer data. Forty overweight or obese women (mean age = 55.2 ± 15.3 yr; BMI = 32.0 ± 3.7) wore two ActiGraph GT3X+ accelerometers (right hip, nondominant wrist; ActiGraph, Pensacola, FL) for seven free-living days. Wearable cameras captured ground truth activity labels. A classifier consisting of a random forest and hidden Markov model classified the accelerometer data into four activities (sitting, standing, walking/running, and riding in a vehicle). Free-living wrist and hip ML classifiers were compared with each other, with traditional accelerometer cut points, and with an algorithm developed in a laboratory setting. The ML classifier obtained average values of 89.4% and 84.6% balanced accuracy over the four activities using the hip and wrist accelerometer, respectively. In our data set with average values of 28.4 min of walking or running per day, the ML classifier predicted average values of 28.5 and 24.5 min of walking or running using the hip and wrist accelerometer, respectively. Intensity-based cut points and the laboratory algorithm significantly underestimated walking minutes. Our results demonstrate the superior performance of our PA-type classification algorithm, particularly in comparison with traditional cut points. Although the hip algorithm performed better, additional compliance achieved with wrist devices might justify using a slightly lower performing algorithm.

  13. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    PubMed

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. A brief tool to differentiate factors contributing to insomnia complaints.

    PubMed

    Townsend, Donald; Kazaglis, Louis; Savik, Kay; Smerud, Adam; Iber, Conrad

    2017-03-01

    A complaint of insomnia may have many causes. A brief tool examining contributing factors may be useful for nonsleep specialists. This study describes the development of the Insomnia Symptoms Assessment (ISA) for examining insomnia complaints. ISA questions were designed to identify symptoms that may represent 1 of 8 possible factors contributing to insomnia symptoms, including delayed sleep phase syndrome (DSPS), shift work sleep disorder (SWSD), obstructive sleep apnea (OSA), mental health, chronic pain, restless leg syndrome (RLS), poor sleep hygiene, and psychophysiological insomnia (PI). The ISA was completed by 346 new patients. Patients met with a sleep specialist who determined primary and secondary diagnoses. Mean age was 45 (18-85) years and 51% were male. Exploratory factor analysis (n = 217) and confirmatory factor analysis (n = 129) supported 5 factors with good internal consistency (Cronbach's alpha), including RLS (.72), OSA (.60), SWSD (.67), DSPS (.64), and PI (.80). Thirty percent had 1 sleep diagnosis with a mean of 2.2 diagnoses per patient. No diagnosis was entered for 1.2% of patients. The receiver operating characteristics were examined and the area under the curves calculated as an indication of convergent validity for the primary diagnosis (N = 346) were .97 for SWSD, .78 for OSA, .67 for DSPS, .54 for PI, and .80 for RLS. The ISA demonstrated good internal consistency and corresponds well to expert diagnoses. Next steps include setting sensitivity/specificity cutoffs to suggest initial treatment recommendations for use in other settings. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  15. Linear biocompatible glyco-polyamidoamines as dual action mode virus infection inhibitors with potential as broad-spectrum microbicides for sexually transmitted diseases

    NASA Astrophysics Data System (ADS)

    Mauro, Nicolò; Ferruti, Paolo; Ranucci, Elisabetta; Manfredi, Amedea; Berzi, Angela; Clerici, Mario; Cagno, Valeria; Lembo, David; Palmioli, Alessandro; Sattin, Sara

    2016-09-01

    The initial steps of viral infections are mediated by interactions between viral proteins and cellular receptors. Blocking the latter with high-affinity ligands may inhibit infection. DC-SIGN, a C-type lectin receptor expressed by immature dendritic cells and macrophages, mediates human immunodeficiency virus (HIV) infection by recognizing mannose clusters on the HIV-1 gp120 envelope glycoprotein. Mannosylated glycodendrimers act as HIV entry inhibitors thanks to their ability to block this receptor. Previously, an amphoteric, but prevailingly cationic polyamidoamine named AGMA1 proved effective as infection inhibitor for several heparan sulfate proteoglycan-dependent viruses, such as human papilloma virus HPV-16 and herpes simplex virus HSV-2. An amphoteric, but prevailingly anionic PAA named ISA23 proved inactive. It was speculated that the substitution of mannosylated units for a limited percentage of AGMA1 repeating units, while imparting anti-HIV activity, would preserve the fundamentals of its HPV-16 and HSV-2 infection inhibitory activity. In this work, four biocompatible linear PAAs carrying different amounts of mannosyl-triazolyl pendants, Man-ISA7, Man-ISA14, Man-AGMA6.5 and Man-AGMA14.5, were prepared by reaction of 2-(azidoethyl)-α-D-mannopyranoside and differently propargyl-substituted AGMA1 and ISA23. All mannosylated PAAs inhibited HIV infection. Both Man-AGMA6.5 and Man-AGMA14.5 maintained the HPV-16 and HSV-2 activity of the parent polymer, proving broad-spectrum, dual action mode virus infection inhibitors.

  16. Electrical activity of the cingulate cortex. II. Cholinergic modulation.

    PubMed

    Borst, J G; Leung, L W; MacFabe, D F

    1987-03-24

    The role of the cholinergic innervation in the modulation of cingulate electrical activity was studied by means of pharmacological manipulations and brain lesions. In the normal rat, an irregular slow activity (ISA) accompanied with EEG-spikes was recorded in the cingulate cortex during immobility as compared to walking. Atropine sulfate, but not atropine methyl nitrate, increased ISA and the frequency of cingulate EEG-spikes. Pilocarpine suppressed ISA and EEG-spikes during immobility, and induced a slow (4-7 Hz) theta rhythm. Unilateral or bilateral lesions of the substantia innominata and ventral globus pallidus area using kainic acid did not significantly change the cingulate EEG or its relation to behavior. Large electrolytic lesions of the medial septal nuclei and vertical limbs of the diagonal band generally decreased or abolished all theta activity in the cingulate cortex and the hippocampus. However, in 5 rats the cingulate theta rhythm increased while the hippocampal theta disappeared after a medial septal lesion. The large, postlesion cingulate theta, accompanied by sharp EEG-spikes during its negative phase, is an unequivocal demonstration of the existence of a theta rhythm in the cingulate cortex, independent of the hippocampal rhythm. Cholinergic afferents from the medial septum and diagonal band nuclei are inferred to be responsible for the behavioral suppression of cingulate EEG-spikes and ISA, and partially for the generation of a local cingulate theta rhythm. However, an atropine-resistant pathway and a theta-suppressing pathway, possibly coming from the medial septum or the hippocampus, may also be important in cingulate theta generation.

  17. Effectiveness and acceptance of the intelligent speeding prediction system (ISPS).

    PubMed

    Zhao, Guozhen; Wu, Changxu

    2013-03-01

    The intelligent speeding prediction system (ISPS) is an in-vehicle speed assistance system developed to provide quantitative predictions of speeding. Although the ISPS's prediction of speeding has been validated, whether the ISPS can regulate a driver's speed behavior or whether a driver accepts the ISPS needs further investigation. Additionally, compared to the existing intelligent speed adaptation (ISA) system, whether the ISPS performs better in terms of reducing excessive speeds and improving driving safety needs more direct evidence. An experiment was conducted to assess and compare the effectiveness and acceptance of the ISPS and the ISA. We conducted a driving simulator study with 40 participants. System type served as a between-subjects variable with four levels: no speed assistance system, pre-warning system developed based on the ISPS, post-warning system ISA, and combined pre-warning and ISA system. Speeding criterion served as a within-subjects variable with two levels: lower (posted speed limit plus 1 mph) and higher (posted speed limit plus 5 mph) speed threshold. Several aspects of the participants' driving speed, speeding measures, lead vehicle response, and subjective measures were collected. Both pre-warning and combined systems led to greater minimum time-to-collision. The combined system resulted in slower driving speed, fewer speeding exceedances, shorter speeding duration, and smaller speeding magnitude. The results indicate that both pre-warning and combined systems have the potential to improve driving safety and performance. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Contributions to the problem of piezoelectric accelerometer calibration. [using lock-in voltmeter

    NASA Technical Reports Server (NTRS)

    Jakab, I.; Bordas, A.

    1974-01-01

    After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

  19. Review of physical activity measurement using accelerometers in older adults: considerations for research design and conduct.

    PubMed

    Murphy, Susan L

    2009-02-01

    Accelerometers are being increasingly used in studies of physical activity (PA) among older adults, however the use of these monitors requires some specialized knowledge and up-to-date information on technological innovations. The purpose of this review article is to provide researchers with a guide to some commonly-used accelerometers in order to better design and conduct PA research with older adults. A literature search was conducted to obtain all available literature on commonly-used accelerometers in older adult samples with specific attention to articles discussing research design. The use of accelerometers in older adults requires a basic understanding of the type being used, rationale for their placement, and attention to calibration when needed. The updated technology in some monitors should make study conduct less difficult, however comparison studies of the newer versus the older generation models will be needed. Careful considerations for design and conduct of accelerometer research as outlined in this review should help to enhance the quality and comparability of future research studies.

  20. C-arm rotation encoding with accelerometers.

    PubMed

    Grzeda, Victor; Fichtinger, Gabor

    2010-07-01

    Fluoroscopic C-arms are being incorporated in computer-assisted interventions in increasing number. For these applications to work, the relative poses of imaging must be known. To find the pose, tracking methods such as optical cameras, electromagnetic trackers, and radiographic fiducials have been used-all hampered by significant shortcomings. We propose to recover the rotational pose of the C-arm using the angle-sensing ability of accelerometers, by exploiting the capability of the accelerometer to measure tilt angles. By affixing the accelerometer to a C-arm, the accelerometer tracks the C-arm pose during rotations of the C-arm. To demonstrate this concept, a C-arm analogue was constructed with a webcam device affixed to the C-arm model to mimic X-ray imaging. Then, measuring the offset between the accelerometer angle readings to the webcam pose angle, an angle correction equation (ACE) was created to properly tracking the C-arm rotational pose. Several tests were performed on the webcam C-arm model using the ACEs to tracking the primary and secondary angle rotations of the model. We evaluated the capability of linear and polynomial ACEs to tracking the webcam C-arm pose angle for different rotational scenarios. The test results showed that the accelerometer could track the pose of the webcam C-arm model with an accuracy of less than 1.0 degree. The accelerometer was successful in sensing the C-arm's rotation with clinically adequate accuracy in the C-arm webcam model.

  1. Drift mode accelerometry for spaceborne gravity measurements

    NASA Astrophysics Data System (ADS)

    Conklin, John W.

    2015-11-01

    A drift mode accelerometer is a precision instrument for spacecraft that overcomes much of the acceleration noise and readout dynamic range limitations of traditional electrostatic accelerometers. It has the potential of achieving acceleration noise performance similar to that of drag-free systems over a restricted frequency band without the need for external drag-free control or continuous spacecraft propulsion. Like traditional accelerometers, the drift mode accelerometer contains a high-density test mass surrounded by an electrode housing, which can control and sense all six degrees of freedom of the test mass. Unlike traditional accelerometers, the suspension system is operated with a low duty cycle so that the limiting suspension force noise only acts over brief, known time intervals, which can be neglected in the data analysis. The readout is performed using a laser interferometer which is immune to the dynamic range limitations of even the best voltage references typically used to determine the inertial acceleration of electrostatic accelerometers. The drift mode accelerometer is a novel offshoot of the like-named operational mode of the LISA Pathfinder spacecraft, in which its test mass suspension system is cycled on and off to estimate the acceleration noise associated with the front-end electronics. This paper presents the concept of a drift mode accelerometer, describes the operation of such a device, develops models for its performance with respect to non-drag-free satellite geodesy and gravitational wave missions, and discusses plans for testing the performance of a prototype sensor in the laboratory using torsion pendula.

  2. A triaxial accelerometer monkey algorithm for optimal sensor placement in structural health monitoring

    NASA Astrophysics Data System (ADS)

    Jia, Jingqing; Feng, Shuo; Liu, Wei

    2015-06-01

    Optimal sensor placement (OSP) technique is a vital part of the field of structural health monitoring (SHM). Triaxial accelerometers have been widely used in the SHM of large-scale structures in recent years. Triaxial accelerometers must be placed in such a way that all of the important dynamic information is obtained. At the same time, the sensor configuration must be optimal, so that the test resources are conserved. The recommended practice is to select proper degrees of freedom (DOF) based upon several criteria and the triaxial accelerometers are placed at the nodes corresponding to these DOFs. This results in non-optimal placement of many accelerometers. A ‘triaxial accelerometer monkey algorithm’ (TAMA) is presented in this paper to solve OSP problems of triaxial accelerometers. The EFI3 measurement theory is modified and involved in the objective function to make it more adaptable in the OSP technique of triaxial accelerometers. A method of calculating the threshold value based on probability theory is proposed to improve the healthy rate of monkeys in a troop generation process. Meanwhile, the processes of harmony ladder climb and scanning watch jump are proposed and given in detail. Finally, Xinghai NO.1 Bridge in Dalian is implemented to demonstrate the effectiveness of TAMA. The final results obtained by TAMA are compared with those of the original monkey algorithm and EFI3 measurement, which show that TAMA can improve computational efficiency and get a better sensor configuration.

  3. Self Diagnostic Accelerometer for Mission Critical Health Monitoring of Aircraft and Spacecraft Engines

    NASA Technical Reports Server (NTRS)

    Lekki, John; Tokars, Roger; Jaros, Dave; Riggs, M. Terrence; Evans, Kenneth P.; Gyekenyesi, Andrew

    2009-01-01

    A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.

  4. Research and Development of Electrostatic Accelerometers for Space Science Missions at HUST.

    PubMed

    Bai, Yanzheng; Li, Zhuxi; Hu, Ming; Liu, Li; Qu, Shaobo; Tan, Dingyin; Tu, Haibo; Wu, Shuchao; Yin, Hang; Li, Hongyin; Zhou, Zebing

    2017-08-23

    High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented.

  5. Research and Development of Electrostatic Accelerometers for Space Science Missions at HUST

    PubMed Central

    Bai, Yanzheng; Li, Zhuxi; Hu, Ming; Liu, Li; Qu, Shaobo; Tan, Dingyin; Tu, Haibo; Wu, Shuchao; Yin, Hang; Li, Hongyin; Zhou, Zebing

    2017-01-01

    High-precision electrostatic accelerometers have achieved remarkable success in satellite Earth gravity field recovery missions. Ultralow-noise inertial sensors play important roles in space gravitational wave detection missions such as the Laser Interferometer Space Antenna (LISA) mission, and key technologies have been verified in the LISA Pathfinder mission. Meanwhile, at Huazhong University of Science and Technology (HUST, China), a space accelerometer and inertial sensor based on capacitive sensors and the electrostatic control technique have also been studied and developed independently for more than 16 years. In this paper, we review the operational principle, application, and requirements of the electrostatic accelerometer and inertial sensor in different space missions. The development and progress of a space electrostatic accelerometer at HUST, including ground investigation and space verification are presented. PMID:28832538

  6. A review of micromachined thermal accelerometers

    NASA Astrophysics Data System (ADS)

    Mukherjee, Rahul; Basu, Joydeep; Mandal, Pradip; Guha, Prasanta Kumar

    2017-12-01

    A thermal convection based micro-electromechanical accelerometer is a relatively new kind of acceleration sensor that does not require a solid proof mass, yielding unique benefits like high shock survival rating, low production cost, and integrability with CMOS integrated circuit technology. This article provides a comprehensive survey of the research, development, and current trends in the field of thermal acceleration sensors, with detailed enumeration on the theory, operation, modeling, and numerical simulation of such devices. Different reported varieties and structures of thermal accelerometers have been reviewed highlighting key design, implementation, and performance aspects. Materials and technologies used for fabrication of such sensors have also been discussed. Further, the advantages and challenges for thermal accelerometers vis-à-vis other prominent accelerometer types have been presented, followed by an overview of associated signal conditioning circuitry and potential applications.

  7. Accelerometry is associated with walking mobility, not physical activity, in persons with multiple sclerosis.

    PubMed

    Weikert, Madeline; Suh, Yoojin; Lane, Abbi; Sandroff, Brian; Dlugonski, Deirdre; Fernhall, Bo; Motl, Robert W

    2012-06-01

    Accelerometers are seemingly a criterion standard of real-life walking mobility and this is supported by assumptions and empirical data. This application would be strengthened by including objective measures of walking mobility along with a matched control sample for verifying specificity versus generality in accelerometer output. We compared associations among accelerometer output, walking mobility, and physical activity between persons with multiple sclerosis (MS) and controls without a neurological disorder. Sixty-six persons (33 MS, 33 matched controls) completed a battery of questionnaires, performed the six-minute walk (6MW) and timed-up-and-go (TUG), and wore an accelerometer for a 7-day period. After this period, participants completed the Godin Leisure-Time Exercise Questionnaire (GLTEQ) and International Physical Activity Questionnaire (IPAQ). Accelerometer output was significantly correlated with only mobility measures (6MW, ρ=.78; TUG, ρ=-.68) in MS, whereas it correlated with both mobility (6MW, ρ=.58; TUG, ρ=-.49) and physical activity (GLTEQ, ρ=.56; IPAQ, ρ=.53) measures in controls. Regression analysis indicated that only 6MW explained variance in accelerometer output in MS (β=.65, R(2)=.43). These findings support the possibility that accelerometers primarily and specifically measure real-life walking mobility, not physical activity, in persons with MS. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Exploring the feasibility and use of acceleromters before, during, and after a camp-based CIMT program for children with cerebral palsy.

    PubMed

    Coker-Bolt, Patty; Downey, Ryan J; Connolly, Jacqueline; Hoover, Reagin; Shelton, Daniel; Seo, Na Jin

    2017-01-01

    The aim of this pilot study was to determine the feasibility and use accelerometers before, during, and after a camp-based constraint-induced movement therapy (CIMT) program for children with hemiplegic cerebral palsy. A pre-test post-test design was used for 12 children with CP (mean = 4.9 yrs) who completed a 30-hour camp-based CIMT program. The accelerometer data were collected using ActiGraph GT9X Link. Children wore accelerometers on both wrists one day before and after the camp and on the affected limb during each camp day. Three developmental assessments were administered pre-post CIMT program. Accelerometers were successfully worn before, during, and directly after the CIMT program to collect upper limb data. Affected upper limb accelerometer activity significantly increased during the CIMT camp compared to baseline (p< 0.05). Significant improvements were seen in all twelve children on all assessments of affected upper limb function (p< 0.05) measuring capacity and quality of affected upper limb functioning. Accelerometers can be worn during high intensity pediatric CIMT programs to collect data about affected upper limb function. Further study is required to determine the relationship between accelerometer data, measure of motor capacity, and real-world performance post-CIMT.

  9. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring

    PubMed Central

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F.; Park, Jong Woong; Mechitov, Kirill

    2018-01-01

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications. PMID:29342102

  10. Development of a High-Sensitivity Wireless Accelerometer for Structural Health Monitoring.

    PubMed

    Zhu, Li; Fu, Yuguang; Chow, Raymond; Spencer, Billie F; Park, Jong Woong; Mechitov, Kirill

    2018-01-17

    Structural health monitoring (SHM) is playing an increasingly important role in ensuring the safety of structures. A shift of SHM research away from traditional wired methods toward the use of wireless smart sensors (WSS) has been motivated by the attractive features of wireless smart sensor networks (WSSN). The progress achieved in Micro Electro-Mechanical System (MEMS) technologies and wireless data transmission, has extended the effectiveness and range of applicability of WSSNs. One of the most common sensors employed in SHM strategies is the accelerometer; however, most accelerometers in WSS nodes have inadequate resolution for measurement of the typical accelerations found in many SHM applications. In this study, a high-resolution and low-noise tri-axial digital MEMS accelerometer is incorporated in a next-generation WSS platform, the Xnode. In addition to meeting the acceleration sensing demands of large-scale civil infrastructure applications, this new WSS node provides powerful hardware and a robust software framework to enable edge computing that can deliver actionable information. Hardware and software integration challenges are presented, and the associate resolutions are discussed. The performance of the wireless accelerometer is demonstrated experimentally through comparison with high-sensitivity wired accelerometers. This new high-sensitivity wireless accelerometer will extend the use of WSSN to a broader class of SHM applications.

  11. Detailed requirements document for the integrated structural analysis system, phase B

    NASA Technical Reports Server (NTRS)

    Rainey, J. A.

    1976-01-01

    The requirements are defined for a software system entitled integrated Structural Analysis System (ISAS) Phase B which is being developed to provide the user with a tool by which a complete and detailed analysis of a complex structural system can be performed. This software system will allow for automated interface with numerous structural analysis batch programs and for user interaction in the creation, selection, and validation of data. This system will include modifications to the 4 functions developed for ISAS, and the development of 25 new functions. The new functions are described.

  12. InSight Atlas V ASA to ISA Installation

    NASA Image and Video Library

    2018-02-06

    Inside Building B7525 at Vandenberg Air Force Base in California, the aft stub adapter (ASA) is installed to the interstage adapter (ISA) for a United Launch Alliance Atlas V rocket. The launch vehicle will send NASA's Interior Exploration using Seismic Investigations, Geodesy and Heat Transport, or InSight, spacecraft to land on Mars. InSight is the first mission to explore the Red Planet's deep interior. It will investigate processes that shaped the rocky planets of the inner solar system including Earth. Liftoff from Vandenberg is scheduled for May 5, 2018.

  13. Measurement of Impact Acceleration: Mouthpiece Accelerometer Versus Helmet Accelerometer

    PubMed Central

    Higgins, Michael; Halstead, P. David; Snyder-Mackler, Lynn; Barlow, David

    2007-01-01

    Context: Instrumented helmets have been used to estimate impact acceleration imparted to the head during helmet impacts. These instrumented helmets may not accurately measure the actual amount of acceleration experienced by the head due to factors such as helmet-to-head fit. Objective: To determine if an accelerometer attached to a mouthpiece (MP) provides a more accurate representation of headform center of gravity (HFCOG) acceleration during impact than does an accelerometer attached to a helmet fitted on the headform. Design: Single-factor research design in which the independent variable was accelerometer position (HFCOG, helmet, MP) and the dependent variables were g and Severity Index (SI). Setting: Independent impact research laboratory. Intervention(s): The helmeted headform was dropped (n = 168) using a National Operating Committee on Standards for Athletic Equipment (NOCSAE) drop system from the standard heights and impact sites according to NOCSAE test standards. Peak g and SI were measured for each accelerometer position during impact. Main Outcome Measures: Upon impact, the peak g and SI were recorded for each accelerometer location. Results: Strong relationships were noted for HFCOG and MP measures, and significant differences were seen between HFCOG and helmet g measures and HFCOG and helmet SI measures. No statistically significant differences were noted between HFCOG and MP g and SI measures. Regression analyses showed a significant relationship between HFCOG and MP measures but not between HFCOG and helmet measures. Conclusions: Upon impact, MP acceleration (g) and SI measurements were closely related to and more accurate in measuring HFCOG g and SI than helmet measurements. The MP accelerometer is a valid method for measuring head acceleration. PMID:17597937

  14. Measurement method of magnetic field for the wire suspended micro-pendulum accelerometer.

    PubMed

    Lu, Yongle; Li, Leilei; Hu, Ning; Pan, Yingjun; Ren, Chunhua

    2015-04-13

    Force producer is one of the core components of a Wire Suspended Micro-Pendulum Accelerometer; and the stability of permanent magnet in the force producer determines the consistency of the acceleration sensor's scale factor. For an assembled accelerometer; direct measurement of magnetic field strength is not a feasible option; as the magnetometer probe cannot be laid inside the micro-space of the sensor. This paper proposed an indirect measurement method of the remnant magnetization of Micro-Pendulum Accelerometer. The measurement is based on the working principle of the accelerometer; using the current output at several different scenarios to resolve the remnant magnetization of the permanent magnet. Iterative Least Squares algorithm was used for the adjustment of the data due to nonlinearity of this problem. The calculated remnant magnetization was 1.035 T. Compared to the true value; the error was less than 0.001 T. The proposed method provides an effective theoretical guidance for measuring the magnetic field of the Wire Suspended Micro-Pendulum Accelerometer; correcting the scale factor and temperature influence coefficients; etc.

  15. A digital output piezoelectric accelerometer using a Pb(Zr, Ti)O3 thin film array electrically connected in series

    NASA Astrophysics Data System (ADS)

    Kobayashi, T.; Okada, H.; Masuda, T.; Maeda, R.; Itoh, T.

    2010-10-01

    A digital output piezoelectric accelerometer is proposed to realize an ultra-low power consumption wireless sensor node. The accelerometer has patterned piezoelectric thin films (piezoelectric plates) electrically connected in series accompanied by CMOS switches at the end of some of the piezoelectric plates. The connected piezoelectric plates amplify the output voltage without the use of amplifiers. The CMOS switches turn on when the output voltage of the piezoelectric plates is higher than the CMOS threshold voltage. The piezoelectric accelerometer converts the acceleration into a number of on-state CMOS switches, which can be called the digital output. The proposed digital output piezoelectric accelerometer, using Pb(Zr, Ti)O3 (PZT) thin films as the piezoelectric material, was fabricated through a microelectromechanical system (MEMS) microfabrication process. The output voltage was found to be amplified by the number of connected piezoelectric plates. The DC output voltage obtained by using an AC to DC conversion circuit is proportional to the number of connections. The results show the potential for realizing the proposed digital output piezoelectric accelerometer.

  16. Building Scientific Data's list of recommended data repositories

    NASA Astrophysics Data System (ADS)

    Hufton, A. L.; Khodiyar, V.; Hrynaszkiewicz, I.

    2016-12-01

    When Scientific Data launched in 2014 we provided our authors with a list of recommended data repositories to help them identify data hosting options that were likely to meet the journal's requirements. This list has grown in size and scope, and is now a central resource for authors across the Nature-titled journals. It has also been used in the development of data deposition policies and recommended repository lists across Springer Nature and at other publishers. Each new addition to the list is assessed according to a series of criteria that emphasize the stability of the resource, its commitment to principles of open science and its implementation of relevant community standards and reporting guidelines. A preference is expressed for repositories that issue digital object identifiers (DOIs) through the DataCite system and that share data under the Creative Commons CC0 waiver. Scientific Data currently lists fourteen repositories that focus on specific areas within the Earth and environmental sciences, as well as the broad scope repositories, Dryad and figshare. Readers can browse and filter datasets published at the journal by the host repository using ISA-explorer, a demo tool built by the ISA-tools team at Oxford University1. We believe that well-maintained lists like this one help publishers build a network of trust with community data repositories and provide an important complement to more comprehensive data repository indices and more formal certification efforts. In parallel, Scientific Data has also improved its policies to better support submissions from authors using institutional and project-specific repositories, without requiring each to apply for listing individually. Online resources Journal homepage: http://www.nature.com/scientificdata Data repository criteria: http://www.nature.com/sdata/policies/data-policies#repo-criteria Recommended data repositories: http://www.nature.com/sdata/policies/repositories Archived copies of the list: https://dx.doi.org/10.6084/m9.figshare.1434640.v6 Reference Gonzalez-Beltran, A. ISA-explorer: A demo tool for discovering and exploring Scientific Data's ISA-tab metadata. Scientific Data Updates http://blogs.nature.com/scientificdata/2015/12/17/isa-explorer/ (2015).

  17. Sexual assault while too intoxicated to resist: a general population study of Norwegian teenage girls.

    PubMed

    Pape, Hilde

    2014-04-28

    Underage drinking is widespread, but studies on alcohol-related sexual victimization among teenage girls are almost non-existent. Research on individual correlates and risk factors of sexual victimization more generally is also meager. This study focuses on sexual assault while incapacitated due to drunkenness among 15-18 year-old girls and examines how age, drinking behavior, impulsivity and involvement in norm-violating activities are associated with such victimization experiences. Data stemmed from a school survey (response rate: 85%) in 16 Norwegian municipalities. Almost all analyses were restricted to girls who had been intoxicated in the past year (n = 2701). In addition to bivariate associations, adjusted odds ratios and relative risks of incapacitated sexual assault (ISA) were estimated. Further, population-attributable fractions were calculated to explore how the prevalence of ISA victimization was likely to be affected if effective preventive measures were targeted solely at high-risk groups. The majority of the girls (71%) had been intoxicated in the past year, of which 7% had experienced ISA victimization in the same period. The proportion of victims decreased by age within the group that had been intoxicated, reflecting that the youngest girls were more likely to get severely drunk. Impulsivity and involvement in norm-violating behaviors were identified as potential risk factors, but the population-attributable fractions indicated that the groups with the highest risk of ISA victimization accounted for only a minority of all the cases of such victimization. Sexual assault against teenage girls who are too drunk to resist seems to be prevalent in Norway - notably among the youngest girls who engage in heavy episodic drinking. This study also suggests that one should reconsider the notion that no individual attributes are related to females' sexual assault victimization. It also indicates that a high risk approach to prevention, targeting groups with a high level of impulsivity or behavioral problems, may have limited effect on the prevalence of ISA victimization. Thus, from a public health perspective, it may be advisable to give priority to universal preventive measures to curb young girls' risk of being sexually assaulted in a state of alcohol-induced incapacitation.

  18. From Peer-Reviewed to Peer-Reproduced in Scholarly Publishing: The Complementary Roles of Data Models and Workflows in Bioinformatics

    PubMed Central

    Zhao, Jun; Avila-Garcia, Maria Susana; Roos, Marco; Thompson, Mark; van der Horst, Eelke; Kaliyaperumal, Rajaram; Luo, Ruibang; Lee, Tin-Lap; Lam, Tak-wah; Edmunds, Scott C.; Sansone, Susanna-Assunta

    2015-01-01

    Motivation Reproducing the results from a scientific paper can be challenging due to the absence of data and the computational tools required for their analysis. In addition, details relating to the procedures used to obtain the published results can be difficult to discern due to the use of natural language when reporting how experiments have been performed. The Investigation/Study/Assay (ISA), Nanopublications (NP), and Research Objects (RO) models are conceptual data modelling frameworks that can structure such information from scientific papers. Computational workflow platforms can also be used to reproduce analyses of data in a principled manner. We assessed the extent by which ISA, NP, and RO models, together with the Galaxy workflow system, can capture the experimental processes and reproduce the findings of a previously published paper reporting on the development of SOAPdenovo2, a de novo genome assembler. Results Executable workflows were developed using Galaxy, which reproduced results that were consistent with the published findings. A structured representation of the information in the SOAPdenovo2 paper was produced by combining the use of ISA, NP, and RO models. By structuring the information in the published paper using these data and scientific workflow modelling frameworks, it was possible to explicitly declare elements of experimental design, variables, and findings. The models served as guides in the curation of scientific information and this led to the identification of inconsistencies in the original published paper, thereby allowing its authors to publish corrections in the form of an errata. Availability SOAPdenovo2 scripts, data, and results are available through the GigaScience Database: http://dx.doi.org/10.5524/100044; the workflows are available from GigaGalaxy: http://galaxy.cbiit.cuhk.edu.hk; and the representations using the ISA, NP, and RO models are available through the SOAPdenovo2 case study website http://isa-tools.github.io/soapdenovo2/. Contact: philippe.rocca-serra@oerc.ox.ac.uk and susanna-assunta.sansone@oerc.ox.ac.uk. PMID:26154165

  19. Study on Misalignment Angle Compensation during Scale Factor Matching for Two Pairs of Accelerometers in a Gravity Gradient Instrument

    PubMed Central

    Huang, Xiangqing; Deng, Zhongguang; Xie, Yafei; Fan, Ji; Hu, Chenyuan

    2018-01-01

    A method for automatic compensation of misalignment angles during matching the scale factors of two pairs of the accelerometers in developing the rotating accelerometer gravity gradient instrument (GGI) is proposed and demonstrated in this paper. The purpose of automatic scale factor matching of the four accelerometers in GGI is to suppress the common mode acceleration of the moving-based platforms. However, taking the full model equation of the accelerometer into consideration, the other two orthogonal axes which is the pendulous axis and the output axis, will also sense the common mode acceleration and reduce the suppression performance. The coefficients from the two axes to the output are δO and δP respectively, called the misalignment angles. The angle δO, coupling with the acceleration along the pendulous axis perpendicular to the rotational plane, will not be modulated by the rotation and gives little contribution to the scale factors matching. On the other hand, because of coupling with the acceleration along the centripetal direction in the rotating plane, the angle δP would produce a component with 90 degrees phase delay relative to the scale factor component. Hence, the δP component coincides exactly with the sensitive direction of the orthogonal accelerometers. To improve the common mode acceleration rejection, the misalignment angle δP is compensated by injecting a trimming current, which is proportional to the output of an orthogonal accelerometer, into the torque coil of the accelerometer during the scale factor matching. The experimental results show that the common linear acceleration suppression achieved three orders after the scale factors balance and five orders after the misalignment angles compensation, which is almost down to the noise level of the used accelerometers of 1~2 × 10−7 g/√Hz (1 g ≈ 9.8 m/s2). PMID:29670021

  20. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time.

    PubMed

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-16

    To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1-4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to -139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Study on Misalignment Angle Compensation during Scale Factor Matching for Two Pairs of Accelerometers in a Gravity Gradient Instrument.

    PubMed

    Huang, Xiangqing; Deng, Zhongguang; Xie, Yafei; Fan, Ji; Hu, Chenyuan; Tu, Liangcheng

    2018-04-18

    A method for automatic compensation of misalignment angles during matching the scale factors of two pairs of the accelerometers in developing the rotating accelerometer gravity gradient instrument (GGI) is proposed and demonstrated in this paper. The purpose of automatic scale factor matching of the four accelerometers in GGI is to suppress the common mode acceleration of the moving-based platforms. However, taking the full model equation of the accelerometer into consideration, the other two orthogonal axes which is the pendulous axis and the output axis, will also sense the common mode acceleration and reduce the suppression performance. The coefficients from the two axes to the output are δ O and δ P respectively, called the misalignment angles. The angle δ O , coupling with the acceleration along the pendulous axis perpendicular to the rotational plane, will not be modulated by the rotation and gives little contribution to the scale factors matching. On the other hand, because of coupling with the acceleration along the centripetal direction in the rotating plane, the angle δ P would produce a component with 90 degrees phase delay relative to the scale factor component. Hence, the δ P component coincides exactly with the sensitive direction of the orthogonal accelerometers. To improve the common mode acceleration rejection, the misalignment angle δ P is compensated by injecting a trimming current, which is proportional to the output of an orthogonal accelerometer, into the torque coil of the accelerometer during the scale factor matching. The experimental results show that the common linear acceleration suppression achieved three orders after the scale factors balance and five orders after the misalignment angles compensation, which is almost down to the noise level of the used accelerometers of 1~2 × 10 −7 g/√Hz (1 g ≈ 9.8 m/s²).

  2. A comprehensive comparison of simple step counting techniques using wrist- and ankle-mounted accelerometer and gyroscope signals.

    PubMed

    Rhudy, Matthew B; Mahoney, Joseph M

    2018-04-01

    The goal of this work is to compare the differences between various step counting algorithms using both accelerometer and gyroscope measurements from wrist and ankle-mounted sensors. Participants completed four different conditions on a treadmill while wearing an accelerometer and gyroscope on the wrist and the ankle. Three different step counting techniques were applied to the data from each sensor type and mounting location. It was determined that using gyroscope measurements allowed for better performance than the typically used accelerometers, and that ankle-mounted sensors provided better performance than those mounted on the wrist.

  3. Timely access to specialist medical oncology services closer to home for rural patients: experience from the Townsville Teleoncology Model.

    PubMed

    Sabesan, Sabe; Roberts, Lynden J; Aiken, Peter; Joshi, Abhishek; Larkins, Sarah

    2014-08-01

    Prior to 2009, the teleoncology model of the Townsville Cancer Centre (TCC) did not achieve its aims of equal waiting times for rural and urban patients and the provision of reliable, local acute cancer care. From 2007-2009, 60 new patients from Mt Isa travelled to TCC for their first consultation and their first dose of chemotherapy. Six of these patients required inter-hospital transfers and eight required urgent flights to attend outpatient clinics. Only 50% these rural patients (n = 30) were reviewed within one week of their referral, compared with 90% of Townsville patients. A descriptive study. TCC provides teleoncology services to 21 rural towns; the largest is Mt Isa, Qld. Specialist review of 90% of urgent cases within 24 hours, and 90% of non-urgent cases within one week of referral via videoconferencing. A 50% reduction in inpatient inter-hospital transfers from Mt Isa to Townsville. Employment of a half-time medical officer and a half-time cancer care coordinator, and implementation of new policies. Between 2009 and 2011, TCC provided cancer care to 70 new patients from Mt Isa. Of these new patients, 93% (65/70) were seen within one week of referral. All 17 patients requiring urgent reviews were seen within 24 hours of referral and managed locally thus eliminating the need for inpatient inter-hospital transfers. Provision of timely acute cancer care closer to home requires an increase in the rural case complexity and human resources. © 2014 National Rural Health Alliance Inc.

  4. Degradation of cellulose under alkaline conditions: new insights from a 12 years degradation study.

    PubMed

    Glaus, Martin A; Van Loon, Luc R

    2008-04-15

    Cellulose degradation under alkaline conditions is of relevance to the mobility of many cations of the transition metal, lanthanide, and actinide series in the geosphere because strong complexants such as isosaccharinic acids, 3-deoxy-2-C-hydroxymethyl-D-erythro-pentonic acid (alpha-ISA) and 3-deoxy-2-C-hydroxymethyl-D-threo-pentonic acid (beta-ISA) may be formed. In the context of the long-term safety of cementitious repositories for low- and intermediate-level radioactive waste, where large amounts of cellulose may be present, the question of the time scales needed for the complete degradation of cellulose is important. The present paper reports the results of a 12 year study of the degradation of four different cellulosic materials (pure cellulose, tissue, cotton, paper) in an artificial cement pore water under anaerobic conditions at approximately 25 degrees C. The observed reaction characteristics can be divided into a fast reaction phase (2-3 years), dominated by the stepwise conversion of terminal glucose monomeric units to alpha-ISA and beta-ISA, and a very slow reaction phase during which the same products were found. The slow rate of the alkaline degradation of cellulose during this second reaction phase shows that previous kinetic models of cellulose degradation did not adequately describe the long-term behavior under alkaline conditions and need to be reassessed. It is postulated that a previously unknown mechanism by which crystalline or inaccessible reducing end groups of the polysaccharide chain become temporarily susceptible to alkaline attack is responsible for the slow rate of cellulose degradation.

  5. Peptide vaccination of patients with metastatic melanoma: improved clinical outcome in patients demonstrating effective immunization.

    PubMed

    Markovic, Svetomir N; Suman, Vera J; Ingle, James N; Kaur, Judith S; Pitot, Henry C; Loprinzi, Charles L; Rao, Ravi D; Creagan, Edward T; Pittelkow, Mark R; Allred, Jakob B; Nevala, Wendy K; Celis, Esteban

    2006-08-01

    Therapeutic peptide vaccines for melanoma continue to only demonstrate anecdotal success. We set out to evaluate the impact of low-dose GM-CSF emulsified in Montanide ISA-51 on the immunogenicity of HLA-A2 restricted melanoma differentiation antigen peptide vaccines (MART-1, gp100 and tyrosinase) administered in separate subcutaneous injections. We conducted a randomized phase II clinical trial of HLA-A2+ patients with metastatic melanoma that were immunized every 3 weeks with one of the following vaccine preparations: (A) peptides + Montanide ISA-51; (B) peptides + Montanide ISA-51 + GM-CSF (10 microg); (C) peptides + Montanide ISA-51 + GM-CSF (50 microg). Immunization efficacy was determined by quantification of vaccine specific tetramer positive cytotoxic T cells in peripheral blood. Global assessment of immune competence was ascertained using DTH testing to common recall antigens as well as peripheral blood immunophenotyping. Twenty-five eligible patients were equally distributed across all 3 treatment groups. Only 9 patients demonstrated evidence of immunization. Most commonly, immune response was achieved to the gp100 peptide. The addition of low-dose GM-CSF did not impact immunization efficacy. DTH reactivity to Candida appeared predictive of successful immunization. Successful immunization with the peptide vaccines was associated with improved clinical outcomes. The addition of low dose GM-CSF to peptide vaccines did not enhance immunogenicity. Higher doses of GM-CSF may be needed to achieve this effect and this is a testable hypothesis. Likewise, better patient selection based on immunologic status (DTH reactivity) may be helpful to better understand the clinical impact of therapeutic cancer vaccines.

  6. Finite Element-Assisted Assessment of the Thermo-cyclic Characteristics of Leads Soldered with SnAgCu(+Bi,In) Alloys

    NASA Astrophysics Data System (ADS)

    Lis, Adrian; Nakanishi, Kohei; Matsuda, Tomoki; Sano, Tomokazu; Minagawa, Madoka; Okamoto, Masahide; Hirose, Akio

    2017-07-01

    Solder joints between leads and printed circuit boards in thin small outline packages were produced with conventional Sn1.0Ag0.7Cu (SAC107) and Sn3.0Ag0.7Cu (SAC305) solders as well as various solder alloys with gradually increasing amounts of Bi (up to 3.0 wt.%) and In (up to 1.0 wt.%) within the SAC107 base solder. The reliability of soldered leads in temperature cycle (TC) tests improved most with solder alloys containing both Bi (1.6 wt.%) and In (0.5 wt.%). Microindentation and electron probe microanalysis mappings revealed that the effect originates from a combination of solution and precipitation strengthening of the initial SAC alloy. The distribution of inelastic strain accumulation (ISA), as a measure for degradation, was determined in the solder joints by finite element calculations. It was shown that defects in the solder proximal to the lead (<60-75 μm) strongly impact the reliability and provoke crack initiation around the defect where the highest ISA is located. In particular, similar TC performance can be expected for defect-free joints and for those whose defects exceed the threshold distance from the lead (>60-75 μm), which was underpinned by similar cracking characteristics along the lead-solder interface. The ISA was confirmed to be lower in SAC+Bi/In alloys owing to their enhanced elasto-plastic properties. Moreover, the addition of a thin Cu coating on the leads could improve the joint reliability, as suggested by the calculation of the ISA and the acceleration factor.

  7. Visual experience sculpts whole-cortex spontaneous infraslow activity patterns through an Arc-dependent mechanism

    PubMed Central

    Kraft, Andrew W.; Mitra, Anish; Bauer, Adam Q.; Raichle, Marcus E.; Culver, Joseph P.; Lee, Jin-Moo

    2017-01-01

    Decades of work in experimental animals has established the importance of visual experience during critical periods for the development of normal sensory-evoked responses in the visual cortex. However, much less is known concerning the impact of early visual experience on the systems-level organization of spontaneous activity. Human resting-state fMRI has revealed that infraslow fluctuations in spontaneous activity are organized into stereotyped spatiotemporal patterns across the entire brain. Furthermore, the organization of spontaneous infraslow activity (ISA) is plastic in that it can be modulated by learning and experience, suggesting heightened sensitivity to change during critical periods. Here we used wide-field optical intrinsic signal imaging in mice to examine whole-cortex spontaneous ISA patterns. Using monocular or binocular visual deprivation, we examined the effects of critical period visual experience on the development of ISA correlation and latency patterns within and across cortical resting-state networks. Visual modification with monocular lid suturing reduced correlation between left and right cortices (homotopic correlation) within the visual network, but had little effect on internetwork correlation. In contrast, visual deprivation with binocular lid suturing resulted in increased visual homotopic correlation and increased anti-correlation between the visual network and several extravisual networks, suggesting cross-modal plasticity. These network-level changes were markedly attenuated in mice with genetic deletion of Arc, a gene known to be critical for activity-dependent synaptic plasticity. Taken together, our results suggest that critical period visual experience induces global changes in spontaneous ISA relationships, both within the visual network and across networks, through an Arc-dependent mechanism. PMID:29087327

  8. An Accelerometer as an Alternative to a Force Plate for the Step-Up-and-Over Test.

    PubMed

    Bailey, Christopher A; Costigan, Patrick A

    2015-12-01

    The step-up-and-over test has been used successfully to examine knee function after knee injury. Knee function is quantified using the following variables extracted from force plate data: the maximal force exerted during the lift, the maximal impact force at landing, and the total time to complete the step. For various reasons, including space and cost, it is unlikely that all clinicians will have access to a force plate. The purpose of the study was to determine if the step-up-and-over test could be simplified by using an accelerometer. The step-up-and-over test was performed by 17 healthy young adults while being measured with both a force plate and a 3-axis accelerometer mounted at the low back. Results showed that the accelerometer and force plate measures were strongly correlated for all 3 variables (r = .90-.98, Ps < .001) and that the accelerometer values for the lift and impact indices were 6-7% higher (Ps < .01) and occurred 0.07-0.1 s later than the force plate (Ps < .05). The accelerometer returned values highly correlated to those from a force plate. Compared with a force plate, a wireless, 3-axis accelerometer is a less expensive and more portable system with which to measure the step-up-and-over test.

  9. Mechanical design of a single-axis monolithic accelerometer for advanced seismic attenuation systems

    NASA Astrophysics Data System (ADS)

    Bertolini, Alessandro; DeSalvo, Riccardo; Fidecaro, Francesco; Francesconi, Mario; Marka, Szabolcs; Sannibale, Virginio; Simonetti, Duccio; Takamori, Akiteru; Tariq, Hareem

    2006-01-01

    The design and mechanics for a new very-low noise low frequency horizontal accelerometer is presented. The sensor has been designed to be integrated in an advanced seismic isolation system for interferometric gravitational wave detectors. The motion of a small monolithic folded-pendulum (FP) is monitored by a high resolution capacitance displacement sensor; a feedback force actuator keeps the mass at the equilibrium position. The feedback signal is proportional to the ground acceleration in the frequency range 0-150 Hz. The very high mechanical quality factor, Q≃3000 at a resonant frequency of 0.5 Hz, reduces the Brownian motion of the proof mass of the accelerometer below the resolution of the displacement sensor. This scheme enables the accelerometer to detect the inertial displacement of a platform with a root-mean-square noise less than 1 nm, integrated over the frequency band from 0.01 to 150 Hz. The FP geometry, combined with the monolithic design, allows the accelerometer to be extremely directional. A vertical-horizontal coupling ranging better than 10-3 has been achieved. A detailed account of the design and construction of the accelerometer is reported here. The instrument is fully ultra-high vacuum compatible and has been tested and approved for integration in seismic attenuation system of japanese TAMA 300 gravitational wave detector. The monolithic design also makes the accelerometer suitable for cryogenic operation.

  10. Physical activity and sedentary behavior during pregnancy and postpartum, measured using hip and wrist-worn accelerometers.

    PubMed

    Hesketh, Kathryn R; Evenson, Kelly R; Stroo, Marissa; Clancy, Shayna M; Østbye, Truls; Benjamin-Neelon, Sara E

    2018-06-01

    Physical activity in pregnancy and postpartum is beneficial to mothers and infants. To advance knowledge of objective physical activity measurement during these periods, this study compares hip to wrist accelerometer compliance; assesses convergent validity (correlation) between hip- and wrist-worn accelerometry; and assesses change in physical activity from pregnancy to postpartum. We recruited women during pregnancy ( n  = 100; 2014-2015), asking them to wear hip and wrist accelerometers for 7 days during Trimester 2 (T2), Trimester 3 (T3), and 3-, 6-, 9- and 12-months postpartum. We assessed average wear-time and correlations (axis-specific counts/minute, vector magnitude counts/day and step counts/day) at T2, T3, and postpartum. Compliance was higher for wrist-worn accelerometers. Hip and wrist accelerometers showed moderate to high correlations (Pearson's r 0.59 to 0.84). Hip-measured sedentary and active time differed little between T2 and T3. Moderate-to-vigorous physical activity decreased at T3 and remained low postpartum. Light physical activity increased and sedentary time decreased throughout the postpartum period. Wrist accelerometers may be preferable during pregnancy and appear comparable to hip accelerometers. As physical activity declines during later pregnancy and may not rebound post birth, support for re-engaging in physical activity earlier in the postpartum period may benefit women.

  11. Indian Society for Apheresis and apheresis tourism in India--is there a future?

    PubMed

    Srivastava, R

    2006-04-01

    Apheresis has now become an internationally popular mode of treatment for multiple immune complex disorders. However, the treatment remains quite expensive in Western Europe and the US. Apheresis tourism is a part of medical tourism or medical tourism specially related to therapeutic apheresis (TA) treatment in a foreign country on a cost effective basis. In the last couple of years, 'Medical Tourism' has become an upcoming and growing enterprise in India. The Indian Society for Apheresis (ISA) has taken a plunge at the opportune time and is trying to promote apheresis tourism in India. ISA is a member of various international apheresis organizations globally including the World Apheresis Association (WAA), the International Society for Apheresis (ISFA), the International Society for Artificial Organs (ISAO) and an associate of other national apheresis societies. The Indian Society for Apheresis (ISA) and the Ludhiana MediCiti (LMC) at Ludhiana Punjab are taking a big step in this direction. The therapeutic apheresis (TA) center at LMC is being set up as a Therapeutic Apheresis Institute and Research Center of excellence. The potential future impacts on the apheresis scenario are summarized.

  12. Accelerometer telemetry system

    NASA Technical Reports Server (NTRS)

    Konigsberg, E. (Inventor)

    1976-01-01

    An accelerometer telemetry system incorporated in a finger ring is used for monitoring the motor responses of a subject. The system includes an accelerometer, battery, and transmitter and provides information to a remote receiver regarding hand movements of a subject wearing the ring, without the constraints of wires. Possible applications include the detection of fatigue from the hand movements of the wearer.

  13. Linear Acceleration Measurement Utilizing Inter-Instrument Synchronization: A Comparison between Accelerometers and Motion-Based Tracking Approaches

    ERIC Educational Resources Information Center

    Callaway, Andrew J.; Cobb, Jon E.

    2012-01-01

    Where as video cameras are a reliable and established technology for the measurement of kinematic parameters, accelerometers are increasingly being employed for this type of measurement due to their ease of use, performance, and comparatively low cost. However, the majority of accelerometer-based studies involve a single channel due to the…

  14. Assessing Physical Activity in Children with Asthma: Convergent Validity between Accelerometer and Electronic Diary Data

    ERIC Educational Resources Information Center

    Floro, Josh N.; Dunton, Genevieve F.; Delfino, Ralph J.

    2009-01-01

    Convergent validity of accelerometer and electronic diary physical activity data was assessed in children with asthma. Sixty-two participants, ages 9-18 years, wore an accelerometer and reported their physical activity level in quarter-hour segments every 2 hr using the Ambulatory Diary Assessment (ADA). Moderate validity was found between…

  15. Self Diagnostic Accelerometer Ground Testing on a C-17 Aircraft Engine

    NASA Technical Reports Server (NTRS)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. Sensor system malfunction is a significant contributor to propulsion in flight shutdowns (IFSD) which can lead to aircraft accidents when the issue is compounded with an inappropriate crew response. The development of the SDA is important for both reducing the IFSD rate, and hence reducing the rate at which this component failure type can put an aircraft in jeopardy, and also as a critical enabling technology for future automated malfunction diagnostic systems. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to making vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. In an effort toward demonstrating the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The two SDA attachment conditions used were fully tight and loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first time the robustness of the SDA in an engine environment characterized by high vibration levels.

  16. Self diagnostic accelerometer ground testing on a C-17 aircraft engine

    NASA Astrophysics Data System (ADS)

    Tokars, Roger P.; Lekki, John D.

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. Sensor system malfunction is a significant contributor to propulsion in flight shutdowns (IFSD) which can lead to aircraft accidents when the issue is compounded with an inappropriate crew response. The development of the SDA is important for both reducing the IFSD rate, and hence reducing the rate at which this component failure type can put an aircraft in jeopardy, and also as a critical enabling technology for future automated malfunction diagnostic systems. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to making vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. In an effort toward demonstrating the SDA's flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The two SDA attachment conditions used were fully tight and loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first time the robustness of the SDA in an engine environment characterized by high vibration levels.

  17. Accelerometer use during field-based physical activity research in children and adolescents with intellectual disabilities: a systematic review.

    PubMed

    McGarty, Arlene M; Penpraze, Victoria; Melville, Craig A

    2014-05-01

    Many methodological questions and issues surround the use of accelerometers as a measure of physical activity during field-based research. To ensure overall research quality and the accuracy of results, methodological decisions should be based on study research questions. This paper aims to systematically review accelerometer use during field-based research in children and adolescents with intellectual disabilities. Medline, Embase, Cochrane Library, Web of Knowledge, PsycINFO, PubMed, and a thesis database (up to May 2013) were searched to identify relevant articles. Articles which used accelerometry-based monitors, quantified activity levels, and included ambulatory children and adolescents (≤ 18 years) with intellectual disabilities were included. Based on best practice guidelines, a form was developed to extract data based on 17 research components of accelerometer use. The search identified 429 articles. Ten full-text articles met the criteria and were included in the review. Many shortcomings in accelerometer use were identified, with the percentage of review criteria met ranging from 12% to 47%. Various methods of accelerometer use were reported, with most use decisions not based on population-specific research. However, a lack of measurement research, e.g., calibration/validation, for children and adolescents with intellectual disabilities is limiting the ability of field-based researchers to make to the most appropriate accelerometer use decisions. The methods of accelerometer use employed can have significant effects on the quality and validity of results produced, which researchers should be more aware of. To allow informed use decisions, there should be a greater focus on measurement research related to children and adolescents with intellectual disabilities. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Validation of accelerometer wear and nonwear time classification algorithm.

    PubMed

    Choi, Leena; Liu, Zhouwen; Matthews, Charles E; Buchowski, Maciej S

    2011-02-01

    the use of movement monitors (accelerometers) for measuring physical activity (PA) in intervention and population-based studies is becoming a standard methodology for the objective measurement of sedentary and active behaviors and for the validation of subjective PA self-reports. A vital step in PA measurement is the classification of daily time into accelerometer wear and nonwear intervals using its recordings (counts) and an accelerometer-specific algorithm. the purpose of this study was to validate and improve a commonly used algorithm for classifying accelerometer wear and nonwear time intervals using objective movement data obtained in the whole-room indirect calorimeter. we conducted a validation study of a wear or nonwear automatic algorithm using data obtained from 49 adults and 76 youth wearing accelerometers during a strictly monitored 24-h stay in a room calorimeter. The accelerometer wear and nonwear time classified by the algorithm was compared with actual wearing time. Potential improvements to the algorithm were examined using the minimum classification error as an optimization target. the recommended elements in the new algorithm are as follows: 1) zero-count threshold during a nonwear time interval, 2) 90-min time window for consecutive zero or nonzero counts, and 3) allowance of 2-min interval of nonzero counts with the upstream or downstream 30-min consecutive zero-count window for detection of artifactual movements. Compared with the true wearing status, improvements to the algorithm decreased nonwear time misclassification during the waking and the 24-h periods (all P values < 0.001). the accelerometer wear or nonwear time algorithm improvements may lead to more accurate estimation of time spent in sedentary and active behaviors.

  19. Calibration of GENEActiv accelerometer wrist cut-points for the assessment of physical activity intensity of preschool aged children.

    PubMed

    Roscoe, Clare M P; James, Rob S; Duncan, Michael J

    2017-08-01

    This study sought to validate cut-points for use of wrist-worn GENEActiv accelerometer data, to analyse preschool children's (4 to 5 year olds) physical activity (PA) levels via calibration with oxygen consumption values (VO 2 ). This was a laboratory-based calibration study. Twenty-one preschool children, aged 4.7 ± 0.5 years old, completed six activities (ranging from lying supine to running) whilst wearing the GENEActiv accelerometers at two locations (left and right wrist), these being the participants' non-dominant and dominant wrist, and a Cortex face mask for gas analysis. VO 2 data was used for the assessment of criterion validity. Location specific activity intensity cut-points were established via receiver operator characteristic curve (ROC) analysis. The GENEActiv accelerometers, irrespective of their location, accurately discriminated between all PA intensities (sedentary, light, and moderate and above), with the dominant wrist monitor providing a slightly more precise discrimination at light PA and the non-dominant at the sedentary behaviour and moderate and above intensity levels (area under the curve (AUC) for non-dominant = 0.749-0.993, compared to AUC dominant = 0.760-0.988). This study establishes wrist-worn physical activity cut-points for the GENEActiv accelerometer in preschoolers. What is Known: • GENEActiv accelerometers have been validated as a PA measurement tool in adolescents and adults. • No study to date has validated the GENEActiv accelerometers in preschoolers. What is New: • Cut-points were determined for the wrist-worn GENEActiv accelerometer in preschoolers. • These cut-points can be used in future research to help classify and increase preschoolers' compliance rates with PA.

  20. Reliability and Validity of Objective Measures of Physical Activity in Youth With Cerebral Palsy Who Are Ambulatory.

    PubMed

    O'Neil, Margaret E; Fragala-Pinkham, Maria; Lennon, Nancy; George, Ameeka; Forman, Jeffrey; Trost, Stewart G

    2016-01-01

    Physical therapy for youth with cerebral palsy (CP) who are ambulatory includes interventions to increase functional mobility and participation in physical activity (PA). Thus, reliable and valid measures are needed to document PA in youth with CP. The purpose of this study was to evaluate the inter-instrument reliability and concurrent validity of 3 accelerometer-based motion sensors with indirect calorimetry as the criterion for measuring PA intensity in youth with CP. Fifty-seven youth with CP (mean age=12.5 years, SD=3.3; 51% female; 49.1% with spastic hemiplegia) participated. Inclusion criteria were: aged 6 to 20 years, ambulatory, Gross Motor Function Classification System (GMFCS) levels I through III, able to follow directions, and able to complete the full PA protocol. Protocol activities included standardized activity trials with increasing PA intensity (resting, writing, household chores, active video games, and walking at 3 self-selected speeds), as measured by weight-relative oxygen uptake (in mL/kg/min). During each trial, participants wore bilateral accelerometers on the upper arms, waist/hip, and ankle and a portable indirect calorimeter. Intraclass coefficient correlations (ICCs) were calculated to evaluate inter-instrument reliability (left-to-right accelerometer placement). Spearman correlations were used to examine concurrent validity between accelerometer output (activity and step counts) and indirect calorimetry. Friedman analyses of variance with post hoc pair-wise analyses were conducted to examine the validity of accelerometers to discriminate PA intensity across activity trials. All accelerometers exhibited excellent inter-instrument reliability (ICC=.94-.99) and good concurrent validity (rho=.70-.85). All accelerometers discriminated PA intensity across most activity trials. This PA protocol consisted of controlled activity trials. Accelerometers provide valid and reliable measures of PA intensity among youth with CP. © 2016 American Physical Therapy Association.

  1. Bulk Micromachined 6H-SiC High-g Piezoresistive Accelerometer Fabricated and Tested

    NASA Technical Reports Server (NTRS)

    Okojie, Robert S.

    2002-01-01

    High-g accelerometers are needed in certain applications, such as in the study and analysis of high-g impact landings and projectiles. Also, these accelerometers must survive the high electromagnetic fields associated with the all-electric vehicle technology needed for aerospace applications. The choice of SiC is largely due to its excellent thermomechanical properties over conventional silicon-based accelerometers, whose material properties inhibit applicability in high electromagnetic radiation and high temperatures (>150 C) unless more complex and sometimes costly packaging schemes are adopted. This work was the outcome of a NASA Glenn Research Center summer internship program, in collaboration with Cornell University and the Munitions Directorate of the U.S. Air Force in Eglin, Florida. It aimed to provide the enabling technology infrastructure (modeling, fabrication, and validation) for the implementation of SiC accelerometers designed specifically for harsh environments.

  2. System for estimating fatigue damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeMonds, Jeffrey; Guzzo, Judith Ann; Liu, Shaopeng

    In one aspect, a system for estimating fatigue damage in a riser string is provided. The system includes a plurality of accelerometers which can be deployed along a riser string and a communications link to transmit accelerometer data from the plurality of accelerometers to one or more data processors in real time. With data from a limited number of accelerometers located at sensor locations, the system estimates an optimized current profile along the entire length of the riser including riser locations where no accelerometer is present. The optimized current profile is then used to estimate damage rates to individual risermore » components and to update a total accumulated damage to individual riser components. The number of sensor locations is small relative to the length of a deepwater riser string, and a riser string several miles long can be reliably monitored along its entire length by fewer than twenty sensor locations.« less

  3. Principle research on a single mass piezoelectric six-degrees-of-freedom accelerometer.

    PubMed

    Liu, Jun; Li, Min; Qin, Lan; Liu, Jingcheng

    2013-08-16

    A signal mass piezoelectric six-degrees-of-freedom (six-DOF) accelerometer is put forward in response to the need for health monitoring of the dynamic vibration characteristics of high grade digitally controlled machine tools. The operating principle of the piezoelectric six-degrees-of-freedom accelerometer is analyzed, and its structure model is constructed. The numerical simulation model (finite element model) of the six axis accelerometer is established. Piezoelectric quartz is chosen for the acceleration sensing element and conversion element, and its static sensitivity, static coupling interference and dynamic natural frequency, dynamic cross coupling are analyzed by ANSYS software. Research results show that the piezoelectric six-DOF accelerometer has advantages of simple and rational structure, correct sensing principle and mathematic model, good linearity, high rigidity, and theoretical natural frequency is more than 25 kHz, no nonlinear cross coupling and no complex decoupling work.

  4. Principle Research on a Single Mass Piezoelectric Six-Degrees-of-Freedom Accelerometer

    PubMed Central

    Liu, Jun; Li, Min; Qin, Lan; Liu, Jingcheng

    2013-01-01

    A signal mass piezoelectric six-degrees-of-freedom (six-DOF) accelerometer is put forward in response to the need for health monitoring of the dynamic vibration characteristics of high grade digitally controlled machine tools. The operating principle of the piezoelectric six-degrees-of-freedom accelerometer is analyzed, and its structure model is constructed. The numerical simulation model (finite element model) of the six axis accelerometer is established. Piezoelectric quartz is chosen for the acceleration sensing element and conversion element, and its static sensitivity, static coupling interference and dynamic natural frequency, dynamic cross coupling are analyzed by ANSYS software. Research results show that the piezoelectric six-DOF accelerometer has advantages of simple and rational structure, correct sensing principle and mathematic model, good linearity, high rigidity, and theoretical natural frequency is more than 25 kHz, no nonlinear cross coupling and no complex decoupling work. PMID:23959243

  5. Influence of time and length size feature selections for human activity sequences recognition.

    PubMed

    Fang, Hongqing; Chen, Long; Srinivasan, Raghavendiran

    2014-01-01

    In this paper, Viterbi algorithm based on a hidden Markov model is applied to recognize activity sequences from observed sensors events. Alternative features selections of time feature values of sensors events and activity length size feature values are tested, respectively, and then the results of activity sequences recognition performances of Viterbi algorithm are evaluated. The results show that the selection of larger time feature values of sensor events and/or smaller activity length size feature values will generate relatively better results on the activity sequences recognition performances. © 2013 ISA Published by ISA All rights reserved.

  6. The Influence of Weather Variation, Urban Design and Built Environment on Objectively Measured Sedentary Behaviour in Children.

    PubMed

    Katapally, Tarun Reddy; Rainham, Daniel; Muhajarine, Nazeem

    2016-01-01

    With emerging evidence indicating that independent of physical activity, sedentary behaviour (SB) can be detrimental to health, researchers are increasingly aiming to understand the influence of multiple contexts such as urban design and built environment on SB. However, weather variation, a factor that continuously interacts with all other environmental variables, has been consistently underexplored. This study investigated the influence of diverse environmental exposures (including weather variation, urban design and built environment) on SB in children. This cross-sectional observational study is part of an active living research initiative set in the Canadian prairie city of Saskatoon. Saskatoon's neighbourhoods were classified based on urban street design into grid-pattern, fractured grid-pattern and curvilinear types of neighbourhoods. Diverse environmental exposures were measured including, neighbourhood built environment, and neighbourhood and household socioeconomic environment. Actical accelerometers were deployed between April and June 2010 (spring-summer) to derive SB of 331 10-14 year old children in 25 one week cycles. Each cycle of accelerometry was conducted on a different cohort of children within the total sample. Accelerometer data were matched with localized weather patterns derived from Environment Canada weather data. Multilevel modeling using Hierarchical Linear and Non-linear Modeling software was conducted by factoring in weather variation to depict the influence of diverse environmental exposures on SB. Both weather variation and urban design played a significant role in SB. After factoring in weather variation, it was observed that children living in grid-pattern neighbourhoods closer to the city centre (with higher diversity of destinations) were less likely to be sedentary. This study demonstrates a methodology that could be replicated to integrate geography-specific weather patterns with existing cross-sectional accelerometry data to understand the influence of urban design and built environment on SB in children.

  7. Silicon microengineering for accelerometers

    NASA Astrophysics Data System (ADS)

    Satchell, D. W.

    Silicon microengineering enables the excellent mechanical properties of silicon to be combined with electronic ones to produce accelerometers of good performance, small size and low cost. The design and fabrication of two types of analogue accelerometer, using this technique, are described. One employs implanted strain gauges to give a dc output, while the other has a strain-sensitive resonant structure which gives a varying frequency signal.

  8. Mother-reported sleep, accelerometer-estimated sleep and weight status in Mexican American children: sleep duration is associated with increased adiposity and risk for overweight/obese status

    USDA-ARS?s Scientific Manuscript database

    We know of no studies comparing parent-reported sleep with accelerometer-estimated sleep in their relation to paediatric adiposity. We examined: (i) the reliability of mother-reported sleep compared with accelerometer-estimated sleep; and (ii) the relationship between both sleep measures and child a...

  9. Actogram analysis of free-flying migratory birds: new perspectives based on acceleration logging.

    PubMed

    Bäckman, Johan; Andersson, Arne; Pedersen, Lykke; Sjöberg, Sissel; Tøttrup, Anders P; Alerstam, Thomas

    2017-07-01

    The use of accelerometers has become an important part of biologging techniques for large-sized birds with accelerometer data providing information about flight mode, wing-beat pattern, behaviour and energy expenditure. Such data show that birds using much energy-saving soaring/gliding flight like frigatebirds and swifts can stay airborne without landing for several months. Successful accelerometer studies have recently been conducted also for free-flying small songbirds during their entire annual cycle. Here we review the principles and possibilities for accelerometer studies in bird migration. We use the first annual actograms (for red-backed shrike Lanius collurio) to explore new analyses and insights that become possible with accelerometer data. Actogram data allow precise estimates of numbers of flights, flight durations as well as departure/landing times during the annual cycle. Annual and diurnal rhythms of migratory flights, as well as prolonged nocturnal flights across desert barriers are illustrated. The shifting balance between flight, rest and different intensities of activity throughout the year as revealed by actogram data can be used to analyse exertion levels during different phases of the life cycle. Accelerometer recording of the annual activity patterns of individual birds will open up a new dimension in bird migration research.

  10. Spring 2014 Internship Diffuser Data Analysis

    NASA Technical Reports Server (NTRS)

    Laigaie, Robert T.; Ryan, Harry M.

    2014-01-01

    J-2X engine testing on the A-2 test stand at the NASA John C. Stennis Space Center (SSC) has recently concluded. As part of that test campaign, the engine was operated at lower power levels in support of expanding the use of J-2X to other missions. However, the A-2 diffuser was not designed for engine testing at the proposed low power levels. To evaluate the risk of damage to the diffuser, computer simulations were created of the rocket engine exhaust plume inside the 50ft long, water-cooled, altitude-simulating diffuser. The simulations predicted that low power level testing would cause the plume to oscillate in the lower sections of the diffuser. This can possibly cause excessive vibrations, stress, and heat transfer from the plume to the diffuser walls. To understand and assess the performance of the diffuser during low power level engine testing, nine accelerometers and four strain gages were installed around the outer surface of the diffuser. The added instrumentation also allowed for the verification of the rocket exhaust plume computational model. Prior to engine hot-fire testing, a diffuser water-flow test was conducted to verify the proper operation of the newly installed instrumentation. Subsequently, two J-2X engine hot-fire tests were completed. Hot-Fire Test 1 was 11.5 seconds in duration, and accelerometer and strain data verified that the rocket engine plume oscillated in the lower sections of the diffuser. The accelerometers showed very different results dependent upon location. The diffuser consists of four sections, with Section 1 being closest to the engine nozzle and Section 4 being farthest from the engine nozzle. Section 1 accelerometers showed increased amplitudes at startup and shutdown, but low amplitudes while the diffuser was started. Section 3 accelerometers showed the opposite results with near zero G amplitudes prior to and after diffuser start and peak amplitudes to +/- 100G while the diffuser was started. Hot-Fire Test 1 strain gages showed different data dependent on section. Section 1 strains were small, and were in the range of 50 to 150 microstrain, which would result in stresses from 1.45 to 4.35 ksi. The yield stress of the material, A-285 Grade C Steel, is 29.7 ksi. Section 4 strain gages showed much higher values with strains peaking at 1600 microstrain. This strain corresponds to a stress of 46.41 ksi, which is in excess of the yield stress, but below the ultimate stress of 55 to 75 ksi. The decreased accelerations and strain in Section 1, and the increased accelerations and strain in Sections 3 and 4 verified the computer simulation prediction of increased plume oscillations in the lower sections of the diffuser. Hot-Fire Test 2 ran for a duration of 125 seconds. The engine operated at a slightly higher power level than Hot-Fire Test 1 for the initial 35 seconds of the test. After 35 seconds the power level was lowered to Hot-Fire Test 1 levels. The acceleration and strain data for Hot-Fire Test 2 was similar during the initial part of the test. However, just prior to the engine being lowered to the Hot-Fire Test 1 power level, the strain gage data in Section 4 showed a large decrease to strains near zero microstrain from their peak at 1500 microstrain. Future work includes further strain and acceleration data analysis and evaluation.

  11. Three-axis accelerometer package for slimhole and microhole seismic monitoring and surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunter, S.L.; Harben, P.E.

    1997-01-07

    The development of microdrilling technology, nominally defined as drilling technology for 1-in.-diameter boreholes, shows potential for reducing the cost of drilling monitoring wells. A major question that arises in drilling microholes is if downhole logging and monitoring in general--and downhole seismic surveying in particular--can be conducted in such small holes since the inner working diameter of such a seismic tool could be as small as 0.31 in. A downhole three-component accelerometer package that fits within a 031-in. inner diameter tube has been designed, built, and tested. The package consists of three orthogonally mounted Entran EGA-125-5g piezoresistive silicon micromachined accelerometers withmore » temperature compensation circuitry, downhole amplification, and line drivers mounted in a thin-walled aluminum tube. Accelerometers are commercially available in much smaller package sizes than conventional geophones, but the noise floor is significantly higher than that for the geophones. Cross-well tests using small explosives showed good signal-to-noise ratio in the recorded waveform at various receiver depths with a 1,50-ft source-receiver well separation. For some active downhole surveys, the accelerometer unit would clearly be adequate. It can be reasonably assumed, however, that for less energetic sources and for greater well separations, the high accelerometer noise floor is not acceptable. By expanding the inner working diameter of a microhole seismic tool to 0.5 in., other commercial accelerometers can be used with substantially lower noise floors.« less

  12. Calibration of Swarm accelerometer data by GPS positioning and linear temperature correction

    NASA Astrophysics Data System (ADS)

    Bezděk, Aleš; Sebera, Josef; Klokočník, Jaroslav

    2018-07-01

    Swarm, a mission of the European Space Agency, consists of three satellites orbiting the Earth since November 2013. In addition to the instrumentation aimed at fulfilling the mission's main goal, which is the observation of Earth's magnetic field, each satellite carries a geodetic quality GPS receiver and an accelerometer. Initially put in a 500-km altitude, all Swarm spacecraft slowly decay due to the action of atmospheric drag. Atmospheric particles and radiation forces impinge on the satellite's surface and thus create the main part of the nongravitational force, which together with satellite-induced thrusts can be measured by space accelerometers. Unfortunately, the Swarm accelerometer data are heavily disturbed by the varying onboard temperature. We calibrate the accelerometer data against a calibration standard derived from observed GPS positions, while making use of the models to represent the forces of gravity origin. We show that this procedure can be extended to incorporate the temperature signal. The obtained calibrated accelerations are validated in several different ways; namely by (i) physically modelled nongravitational forces, by (ii) intercomparison of calibrated accelerometer data from two Swarm satellites flying side-by-side, and by (iii) good agreement of our calibrated signals with those released by ESA, obtained via a different approach for reducing temperature effects. Finally, the presented method is applied to the Swarm C accelerometer data set covering almost two years (July 2014-April 2016), which ESA recently released to scientific users.

  13. Electrostatic Accelerometer for the Gravity Recovery and Climate Experiment Follow-On Mission (GRACE FO)

    NASA Astrophysics Data System (ADS)

    Lebat, V.; Foulon, B.; Christophe, B.

    2013-12-01

    The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics and the Front-End Electronic Unit) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. Besides, a thermal stability is needed for the accelerometer core and front-end electronics to avoid bias and scale factor variation, and reached by a thermal box designed by Astrium, spacecraft manufacturer. The accelerometers are designed to endure the launch vibrations and the thermal environment at ground and in orbit. As the measure must be accurate, no sliding of the core must appear in regard of the accelerometer external reference. To ensure the thermal core stability, the electrode cage of the core is made of glass material (ULE), which is very critical, in particular due to the free motion of the proof-mass during the launch. To assess the design of the accelerometer in particular the critical parts of the core, specific analysis is realized to ensure mechanical behavior. The design of electrostatic accelerometer of the GRACE Follow-On mission benefits of the GRACE heritage, GOCE launched in 2009 and MICROSCOPE which will be launched in 2016, including some improvement to improve the performance, in particular the thermal sensitivity of the measurements. The Preliminary Design Review of electronics was achieved successfully on July 2013, and the PDR of the whole instrument is forecasted on November 2013. The integration of the Engineering Model will begin on October 2013 and its status will be presented.

  14. Detecting Human Activity Using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors

    DTIC Science & Technology

    2011-09-01

    Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors by Sarah H. Walker and Geoffrey H. Goldman...Adelphi, MD 20783-1197 ARL-TR-5729 September 2011 Detecting Human Activity using Acoustic, Seismic, Accelerometer, Video, and E-field Sensors...DD-MM-YYYY) September 2011 2. REPORT TYPE 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE Detecting Human Activity using Acoustic

  15. Physical Activity and Adiposity Markers at Older Ages: Accelerometer Vs Questionnaire Data

    PubMed Central

    Sabia, Séverine; Cogranne, Pol; van Hees, Vincent T.; Bell, Joshua A.; Elbaz, Alexis; Kivimaki, Mika; Singh-Manoux, Archana

    2015-01-01

    Objective Physical activity is critically important for successful aging, but its effect on adiposity markers at older ages is unclear as much of the evidence comes from self-reported data on physical activity. We assessed the associations of questionnaire-assessed and accelerometer-assessed physical activity with adiposity markers in older adults. Design/Setting/Participants This was a cross-sectional study on 3940 participants (age range 60-83 years) of the Whitehall II study who completed a 20-item physical activity questionnaire and wore a wrist-mounted accelerometer for 9 days in 2012 and 2013. Measurements Total physical activity was estimated using metabolic equivalent hours/week for the questionnaire and mean acceleration for the accelerometer. Time spent in moderate-and-vigorous physical activity (MVPA) was also assessed by questionnaire and accelerometer. Adiposity assessment included body mass index, waist circumference, and fat mass index. Fat mass index was calculated as fat mass/height² (kg/m²), with fat mass estimated using bioimpedance. Results Greater total physical activity was associated with lower adiposity for all adiposity markers in a dose-response manner. In men, the strength of this association was 2.4 to 2.8 times stronger with the accelerometer than with questionnaire data. In women, it was 1.9 to 2.3 times stronger. For MVPA, questionnaire data in men suggested no further benefit for adiposity markers past 1 hour/week of activity. This was not the case for accelerometer-assessed MVPA where, for example, compared with men undertaking <1 hour/week of accelerometer-assessed MVPA, waist circumference was 3.06 (95% confidence interval 2.06–4.06) cm lower in those performing MVPA 1–2.5 hours/week, 4.69 (3.47–5.91) cm lower in those undertaking 2.5–4 hours/week, and 7.11 (5.93–8.29) cm lower in those performing ≥4 hours/week. Conclusions The association of physical activity with adiposity markers in older adults was stronger when physical activity was assessed by accelerometer compared with questionnaire, suggesting that physical activity might be more important for adiposity than previously estimated. PMID:25752539

  16. Are physical activity studies in Hispanics meeting reporting guidelines for continuous monitoring technology? A systematic review.

    PubMed

    Layne, Charles S; Parker, Nathan H; Soltero, Erica G; Rosales Chavez, José; O'Connor, Daniel P; Gallagher, Martina R; Lee, Rebecca E

    2015-09-18

    Continuous monitoring technologies such as accelerometers and pedometers are the gold standard for physical activity (PA) measurement. However, inconsistencies in use, analysis, and reporting limit the understanding of dose-response relationships involving PA and the ability to make comparisons across studies and population subgroups. These issues are particularly detrimental to the study of PA across different ethnicities with different PA habits. This systematic review examined the inclusion of published guidelines involving data collection, processing, and reporting among articles using accelerometers or pedometers in Hispanic or Latino populations. English (PubMed; EbscoHost) and Spanish (SCIELO; Biblioteca Virtual en Salud) articles published between 2000 and 2013 using accelerometers or pedometers to measure PA among Hispanics or Latinos were identified through systematic literature searches. Of the 253 abstracts which were initially reviewed, 57 met eligibility criteria (44 accelerometer, 13 pedometer). Articles were coded and reviewed to evaluate compliance with recommended guidelines (N = 20), and the percentage of accelerometer and pedometer articles following each guideline were computed and reported. On average, 57.1 % of accelerometer and 62.2 % of pedometer articles reported each recommended guideline for data collection. Device manufacturer and model were reported most frequently, and provision of instructions for device wear in Spanish was reported least frequently. On average, 29.6 % of accelerometer articles reported each guideline for data processing. Definitions of an acceptable day for inclusion in analyses were reported most frequently, and definitions of an acceptable hour for inclusion in analyses were reported least frequently. On average, 18.8 % of accelerometer and 85.7 % of pedometer articles included each guideline for data reporting. Accelerometer articles most frequently included average number of valid days and least frequently included percentage of wear time. Inclusion of standard collection and reporting procedures in studies using continuous monitoring devices in Hispanic or Latino population is generally low. Lack of reporting consistency in continuous monitoring studies limits researchers' ability to compare studies or draw meaningful conclusions concerning amounts, quality, and benefits of PA among Hispanic or Latino populations. Reporting data collection, computation, and decision-making standards should be required. Improved interpretability would allow practitioners and researchers to apply scientific findings to promote PA.

  17. Pinatubo Emulation in Multiple Models (POEMs): co-ordinated experiments in the ISA-MIP model intercomparison activity component of the SPARC Stratospheric Sulphur and it's Role in Climate initiative (SSiRC)

    NASA Astrophysics Data System (ADS)

    Lee, Lindsay; Mann, Graham; Carslaw, Ken; Toohey, Matthew; Aquila, Valentina

    2016-04-01

    The World Climate Research Program's SPARC initiative has a new international activity "Stratospheric Sulphur and its Role in Climate" (SSiRC) to better understand changes in stratospheric aerosol and precursor gaseous sulphur species. One component of SSiRC involves an intercomparison "ISA-MIP" of composition-climate models that simulate the stratospheric aerosol layer interactively. Within PoEMS each modelling group will run a "perturbed physics ensemble" (PPE) of interactive stratospheric aerosol (ISA) simulations of the Pinatubo eruption, varying several uncertain parameters associated with the eruption's SO2 emissions and model processes. A powerful new technique to quantify and attribute sources of uncertainty in complex global models is described by Lee et al. (2011, ACP). The analysis uses Gaussian emulation to derive a probability density function (pdf) of predicted quantities, essentially interpolating the PPE results in multi-dimensional parameter space. Once trained on the ensemble, a Monte Carlo simulation with the fast Gaussian emulator enabling a full variance-based sensitivity analysis. The approach has already been used effectively by Carslaw et al., (2013, Nature) to quantify the uncertainty in the cloud albedo effect forcing from a 3D global aerosol-microphysics model allowing to compare the sensitivy of different predicted quantities to uncertainties in natural and anthropogenic emissions types, and structural parameters in the models. Within ISA-MIP, each group will carry out a PPE of runs, with the subsequent analysis with the emulator assessing the uncertainty in the volcanic forcings predicted by each model. In this poster presentation we will give an outline of the "PoEMS" analysis, describing the uncertain parameters to be varied and the relevance to further understanding differences identified in previous international stratospheric aerosol assessments.

  18. Accuracy of 3 brief screening questions for detecting partner violence in the emergency department.

    PubMed

    Feldhaus, K M; Koziol-McLain, J; Amsbury, H L; Norton, I M; Lowenstein, S R; Abbott, J T

    1997-05-07

    To devise a brief screening instrument to detect partner violence and to partially validate this screen against established instruments. Prospective survey. Two urban, hospital-based emergency departments. Of 491 women presenting during 48 randomly selected 4-hour time blocks, 322 (76% of eligible patients) participated. Respondents had a median age of 36 years; 19% were black, 45% white, and 30% Hispanic, while 6% were of other racial or ethnic groups; 54% were insured. We developed a partner violence screen (PVS), consisting of 3 questions about past physical violence and perceived personal safety. We administered the PVS and 2 standardized measures of partner violence, the Index of Spouse Abuse (ISA) and the Conflict Tactics Scale (CTS). Sensitivity, specificity, and predictive values of the PVS were compared with the ISA and the CTS as criterion standards. The prevalence rate of partner violence using the PVS was 29.5% (95% confidence interval [CI], 24.6%-34.8%). For the ISA and CTS, the prevalence rates were 24.3% (95% CI, 19.2%-30.1 %) and 27.4% (95% CI, 21.7%-33.6%), respectively. Compared with the ISA, the sensitivity of the PVS in detecting partner abuse was 64.5%; the specificity was 80.3%. When compared with the CTS, sensitivity of the PVS was 71.4%; the specificity was 84.4%. Positive predictive values ranged from 51.3% to 63.4%, and negative predictive values ranged from 87.6% to 88.7%. Overall, 13.7% of visits were the result of acute episodes of partner violence. Three brief directed questions can detect a large number of women who have a history of partner violence.

  19. Mapping cellular Fe-S cluster uptake and exchange reactions - divergent pathways for iron-sulfur cluster delivery to human ferredoxins.

    PubMed

    Fidai, Insiya; Wachnowsky, Christine; Cowan, J A

    2016-12-07

    Ferredoxins are protein mediators of biological electron-transfer reactions and typically contain either [2Fe-2S] or [4Fe-4S] clusters. Two ferredoxin homologues have been identified in the human genome, Fdx1 and Fdx2, that share 43% identity and 69% similarity in protein sequence and both bind [2Fe-2S] clusters. Despite the high similarity, the two ferredoxins play very specific roles in distinct physiological pathways and cannot replace each other in function. Both eukaryotic and prokaryotic ferredoxins and homologues have been reported to receive their Fe-S cluster from scaffold/delivery proteins such as IscU, Isa, glutaredoxins, and Nfu. However, the preferred and physiologically relevant pathway for receiving the [2Fe-2S] cluster by ferredoxins is subject to speculation and is not clearly identified. In this work, we report on in vitro UV-visible (UV-vis) circular dichroism studies of [2Fe-2S] cluster transfer to the ferredoxins from a variety of partners. The results reveal rapid and quantitative transfer to both ferredoxins from several donor proteins (IscU, Isa1, Grx2, and Grx3). Transfer from Isa1 to Fdx2 was also observed to be faster than that of IscU to Fdx2, suggesting that Fdx2 could receive its cluster from Isa1 instead of IscU. Several other transfer combinations were also investigated and the results suggest a complex, but kinetically detailed map for cellular cluster trafficking. This is the first step toward building a network map for all of the possible iron-sulfur cluster transfer pathways in the mitochondria and cytosol, providing insights on the most likely cellular pathways and possible redundancies in these pathways.

  20. Hybridizing matter-wave and classical accelerometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lautier, J.; Volodimer, L.; Hardin, T.

    2014-10-06

    We demonstrate a hybrid accelerometer that benefits from the advantages of both conventional and atomic sensors in terms of bandwidth (DC to 430 Hz) and long term stability. First, the use of a real time correction of the atom interferometer phase by the signal from the classical accelerometer enables to run it at best performance without any isolation platform. Second, a servo-lock of the DC component of the conventional sensor output signal by the atomic one realizes a hybrid sensor. This method paves the way for applications in geophysics and in inertial navigation as it overcomes the main limitation of atomicmore » accelerometers, namely, the dead times between consecutive measurements.« less

  1. Mapping GRACE Accelerometer Error

    NASA Astrophysics Data System (ADS)

    Sakumura, C.; Harvey, N.; McCullough, C. M.; Bandikova, T.; Kruizinga, G. L. H.

    2017-12-01

    After more than fifteen years in orbit, instrument noise, and accelerometer noise in particular, remains one of the limiting error sources for the NASA/DLR Gravity Recovery and Climate Experiment mission. The recent V03 Level-1 reprocessing campaign used a Kalman filter approach to produce a high fidelity, smooth attitude solution fusing star camera and angular acceleration data. This process provided an unprecedented method for analysis and error estimation of each instrument. The accelerometer exhibited signal aliasing, differential scale factors between electrode plates, and magnetic effects. By applying the noise model developed for the angular acceleration data to the linear measurements, we explore the magnitude and geophysical pattern of gravity field error due to the electrostatic accelerometer.

  2. Investigation of Electrostatic Accelerometer in HUST for Space Science Missions

    NASA Astrophysics Data System (ADS)

    Bai, Yanzheng; Hu, Ming; Li, Gui; Liu, Li; Qu, Shaobo; Wu, Shuchao; Zhou, Zebing

    2014-05-01

    High-precision electrostatic accelerometers are significant payload in CHAMP, GRACE and GOCE gravity missions to measure the non-gravitational forces. In our group, space electrostatic accelerometer and inertial sensor based on the capacitive sensors and electrostatic control technique has been investigated for space science research in China such as testing of equivalence principle (TEPO), searching non-Newtonian force in micrometer range, satellite Earth's field recovery and so on. In our group, a capacitive position sensor with a resolution of 10-7pF/Hz1/2 and the μV/Hz1/2 level electrostatic actuator are developed. The fiber torsion pendulum facility is adopt to measure the parameters of the electrostatic controlled inertial sensor such as the resolution, and the electrostatic stiffness, the cross couple between different DOFs. Meanwhile, high voltage suspension and free fall methods are applied to verify the function of electrostatic accelerometer. Last, the engineering model of electrostatic accelerometer has been developed and tested successfully in space and preliminary results are present.

  3. Determination of shuttle orbiter center of gravity from flight measurements

    NASA Technical Reports Server (NTRS)

    Hinson, E. W.; Nicholson, J. Y.; Blanchard, R. C.

    1991-01-01

    Flight measurements of pitch, yaw, and roll rates and the resultant rotationally induced linear accelerations during three orbital maneuvers on Shuttle mission space transportation system (STS) 61-C were used to calculate the actual orbiter center-of-gravity location. The calculation technique reduces error due to lack of absolute calibration of the accelerometer measurements and compensates for accelerometer temperature bias and for the effects of gravity gradient. Accuracy of the technique was found to be limited by the nonrandom and asymmetrical distribution of orbiter structural vibration at the accelerometer mounting location. Fourier analysis of the vibration was performed to obtain the power spectral density profiles which show magnitudes in excess of 10(exp 4) ug (sup 2)/Hz for the actual vibration and over 500 ug (sup 2)/Hz for the filtered accelerometer measurements. The data from this analysis provide a characterization of the Shuttle acceleration environment which may be useful in future studies related to accelerometer system application and zero-g investigations or processes.

  4. MEMS SoC: observer-based coplanar gyro-free inertial measurement unit

    NASA Astrophysics Data System (ADS)

    Chen, Tsung-Lin; Park, Sungsu

    2005-09-01

    This paper presents a novel design of a coplanar gyro-free inertial measurement unit (IMU) that consists of seven to nine single-axis linear accelerometers, and it can be utilized to perform the six DOF measurements for an object in motion. Unlike other gyro-fee IMUs, this design uses redundant accelerometers and state estimation techniques to facilitate the in situ and mass fabrication for the employed accelerometers. The alignment error from positioning accelerometers onto a measurement unit and the fabrication cost of an IMU can greatly be reduced. The outputs of the proposed design are three linear accelerations and three angular velocities. As compared to other gyro-free IMUs, the proposed design uses less integral operation and thus improves its sensing resolution and drifting problem. The sensing resolution of a gyro-free IMU depends on the sensing resolution of the employed accelerometers as well as the size of the measurement unit. Simulation results indicate that the sensing resolution of the proposed design is 2° s-1 for the angular velocity and 10 μg for the linear acceleration when nine single-axis accelerometers, each with 10 μg sensing resolution, are deployed on a 4 inch diameter disc. Also, thanks to the iterative EKF algorithm, the angle estimation error is within 10-3 deg at 2 s.

  5. A microelectromechanical accelerometer fabricated using printed circuit processing techniques

    NASA Astrophysics Data System (ADS)

    Rogers, J. E.; Ramadoss, R.; Ozmun, P. M.; Dean, R. N.

    2008-01-01

    A microelectromechanical systems (MEMS) capacitive-type accelerometer fabricated using printed circuit processing techniques is presented. A Kapton polymide film is used as the structural layer for fabricating the MEMS accelerometer. The accelerometer proof mass along with four suspension beams is defined in the Kapton polyimide film. The proof mass is suspended above a Teflon substrate using a spacer. The deflection of the proof mass is detected using a pair of capacitive sensing electrodes. The top electrode of the accelerometer is defined on the top surface of the Kapton film. The bottom electrode is defined in the metallization on the Teflon substrate. The initial gap height is determined by the distance between the bottom electrode and the Kapton film. For an applied external acceleration (normal to the proof mass), the proof mass deflects toward or away from the fixed bottom electrode due to inertial force. This deflection causes either a decrease or increase in the air-gap height thereby either increasing or decreasing the capacitance between the top and the bottom electrodes. An example PCB MEMS accelerometer with a square proof mass of membrane area 6.4 mm × 6.4 mm is reported. The measured resonant frequency is 375 Hz and the Q-factor in air is 0.52.

  6. Accelerometer-Based Method for Extracting Respiratory and Cardiac Gating Information for Dual Gating during Nuclear Medicine Imaging

    PubMed Central

    Pänkäälä, Mikko; Paasio, Ari

    2014-01-01

    Both respiratory and cardiac motions reduce the quality and consistency of medical imaging specifically in nuclear medicine imaging. Motion artifacts can be eliminated by gating the image acquisition based on the respiratory phase and cardiac contractions throughout the medical imaging procedure. Electrocardiography (ECG), 3-axis accelerometer, and respiration belt data were processed and analyzed from ten healthy volunteers. Seismocardiography (SCG) is a noninvasive accelerometer-based method that measures accelerations caused by respiration and myocardial movements. This study was conducted to investigate the feasibility of the accelerometer-based method in dual gating technique. The SCG provides accelerometer-derived respiratory (ADR) data and accurate information about quiescent phases within the cardiac cycle. The correct information about the status of ventricles and atria helps us to create an improved estimate for quiescent phases within a cardiac cycle. The correlation of ADR signals with the reference respiration belt was investigated using Pearson correlation. High linear correlation was observed between accelerometer-based measurement and reference measurement methods (ECG and Respiration belt). Above all, due to the simplicity of the proposed method, the technique has high potential to be applied in dual gating in clinical cardiac positron emission tomography (PET) to obtain motion-free images in the future. PMID:25120563

  7. Feasibility of Frequency-Modulated Wireless Transmission for a Multi-Purpose MEMS-Based Accelerometer

    PubMed Central

    Sabato, Alessandro; Feng, Maria Q.

    2014-01-01

    Recent advances in the Micro Electro-Mechanical System (MEMS) technology have made wireless MEMS accelerometers an attractive tool for Structural Health Monitoring (SHM) of civil engineering structures. To date, sensors' low sensitivity and accuracy—especially at very low frequencies—have imposed serious limitations for their application in monitoring large-sized structures. Conventionally, the MEMS sensor's analog signals are converted to digital signals before radio-frequency (RF) wireless transmission. The conversion can cause a low sensitivity to the important low-frequency and low-amplitude signals. To overcome this difficulty, the authors have developed a MEMS accelerometer system, which converts the sensor output voltage to a frequency-modulated signal before RF transmission. This is achieved by using a Voltage to Frequency Conversion (V/F) instead of the conventional Analog to Digital Conversion (ADC). In this paper, a prototype MEMS accelerometer system is presented, which consists of a transmitter and receiver circuit boards. The former is equipped with a MEMS accelerometer, a V/F converter and a wireless RF transmitter, while the latter contains an RF receiver and a F/V converter for demodulating the signal. The efficacy of the MEMS accelerometer system in measuring low-frequency and low-amplitude dynamic responses is demonstrated through extensive laboratory tests and experiments on a flow-loop pipeline. PMID:25198003

  8. Feasibility of frequency-modulated wireless transmission for a multi-purpose MEMS-based accelerometer.

    PubMed

    Sabato, Alessandro; Feng, Maria Q

    2014-09-05

    Recent advances in the Micro Electro-Mechanical System (MEMS) technology have made wireless MEMS accelerometers an attractive tool for Structural Health Monitoring (SHM) of civil engineering structures. To date, sensors' low sensitivity and accuracy--especially at very low frequencies--have imposed serious limitations for their application in monitoring large-sized structures. Conventionally, the MEMS sensor's analog signals are converted to digital signals before radio-frequency (RF) wireless transmission. The conversion can cause a low sensitivity to the important low-frequency and low-amplitude signals. To overcome this difficulty, the authors have developed a MEMS accelerometer system, which converts the sensor output voltage to a frequency-modulated signal before RF transmission. This is achieved by using a Voltage to Frequency Conversion (V/F) instead of the conventional Analog to Digital Conversion (ADC). In this paper, a prototype MEMS accelerometer system is presented, which consists of a transmitter and receiver circuit boards. The former is equipped with a MEMS accelerometer, a V/F converter and a wireless RF transmitter, while the latter contains an RF receiver and a F/V converter for demodulating the signal. The efficacy of the MEMS accelerometer system in measuring low-frequency and low-amplitude dynamic responses is demonstrated through extensive laboratory tests and experiments on a flow-loop pipeline.

  9. Accelerometer-based step initiation control for gait-assist neuroprostheses.

    PubMed

    Foglyano, Kevin M; Schnellenberger, John R; Kobetic, Rudi; Lombardo, Lisa; Pinault, Gilles; Selkirk, Stephen; Makowski, Nathaniel S; Triolo, Ronald J

    2016-01-01

    Electrical activation of paralyzed musculature can generate or augment joint movements required for walking after central nervous system trauma. Proper timing of stimulation relative to residual volitional control is critical to usefully affecting ambulation. This study evaluates three-dimensional accelerometers and customized algorithms to detect the intent to step from voluntary movements to trigger stimulation during walking in individuals with significantly different etiologies, mobility limitations, manual dexterities, and walking aids. Three individuals with poststroke hemiplegia or partial spinal cord injury exhibiting varying gait deficits were implanted with multichannel pulse generators to provide joint motions at the hip, knee, and ankle. An accelerometer integrated into the external control unit was used to detect heel strike or walker movement, and wireless accelerometers were used to detect crutch strike. Algorithms were developed for each sensor location to detect intent to step to progress through individualized stimulation patterns. Testing these algorithms produced detection accuracies of at least 90% on both level ground and uneven terrain. All participants use their accelerometer-triggered implanted gait systems in the community; the validation/system testing was completed in the hospital. The results demonstrated that safe, reliable, and convenient accelerometer-based step initiation can be achieved regardless of specific gait deficits, manual dexterities, and walking aids.

  10. Associations of Accelerometer-Measured and Self-Reported Sedentary Time With Leukocyte Telomere Length in Older Women

    PubMed Central

    Shadyab, Aladdin H.; Macera, Caroline A.; Shaffer, Richard A.; Jain, Sonia; Gallo, Linda C.; LaMonte, Michael J.; Reiner, Alexander P.; Kooperberg, Charles; Carty, Cara L.; Di, Chongzhi; Manini, Todd M.; Hou, Lifang; LaCroix, Andrea Z.

    2017-01-01

    Abstract Few studies have assessed the association of sedentary time with leukocyte telomere length (LTL). In a cross-sectional study conducted in 2012–2013, we examined associations of accelerometer-measured and self-reported sedentary time with LTL in a sample of 1,481 older white and African-American women from the Women's Health Initiative and determined whether associations varied by level of moderate- to vigorous-intensity physical activity (MVPA). The association between sedentary time and LTL was evaluated using multiple linear regression models. Women were aged 79.2 (standard deviation, 6.7) years, on average. Self-reported sedentary time was not associated with LTL. In a model adjusting for demographic characteristics, lifestyle behaviors, and health-related factors, among women at or below the median level of accelerometer-measured MVPA, those in the highest quartile of accelerometer-measured sedentary time had significantly shorter LTL than those in the lowest quartile, with an average difference of 170 base pairs (95% confidence interval: 4, 340). Accelerometer-measured sedentary time was not associated with LTL in women above the median level of MVPA. Findings suggest that, on the basis of accelerometer measurements, higher sedentary time may be associated with shorter LTL among less physically active women. PMID:28100466

  11. A sensitivity analysis on the variability in accelerometer data processing for monitoring physical activity.

    PubMed

    Lee, Paul H

    2015-02-01

    Accelerometers are gaining popularity for measuring physical activity, but there are many different ways to process accelerometer data. A sensitivity analysis was conducted to study the effect of varying accelerometer data processing protocols on estimating the association between PA level and socio-demographic characteristics using the National Health and Nutrition Examination Survey (NHANES) accelerometer data. The NHANES waves 2003-2004 and 2005-2006 accelerometer data (n=14,072) were used to investigate the effect of changing the accelerometer non-wearing time and valid day definitions on the demographic composition of the filtered datasets and the association between physical activity (PA) and socio-demographic characteristics (sex, age, race, educational level, marital status). Under different filtering rules (minimum number of valid day and definition of non-wear time), the demographic characteristics of the final sample varied. The proportion of participants aged 20-29 decreased from 18.9% to 15.8% when the minimum number of valid days required increased from 1 to 4 (p for trend<0.001), whereas that for aged ≥70 years increased from 18.9% to 20.6% (p for trend<0.001). Furthermore, with different filters, the effect of these demographic variables and PA varied, with some variables being significant under certain filtering rules but becoming insignificant under some other rules. The sensitivity analysis showed that the significance of the association between socio-demographic variables and PA could be varied with the definition of non-wearing time and minimum number of valid days. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Physical Activity Assessment with the ActiGraph GT3X and Doubly Labeled Water.

    PubMed

    Chomistek, Andrea K; Yuan, Changzheng; Matthews, Charles E; Troiano, Richard P; Bowles, Heather R; Rood, Jennifer; Barnett, Junaidah B; Willett, Walter C; Rimm, Eric B; Bassett, David R

    2017-09-01

    To compare the degree to which four accelerometer metrics-total activity counts per day (TAC per day), steps per day (steps per day), physical activity energy expenditure (PAEE) (kcal·kg·d), and moderate- to vigorous-intensity physical activity (MVPA) (min·d)-were correlated with PAEE measured by doubly labeled water (DLW). Additionally, accelerometer metrics based on vertical axis counts and triaxial counts were compared. This analysis included 684 women and 611 men age 43 to 83 yr. Participants wore the Actigraph GT3X on the hip for 7 d twice during the study and the average of the two measurements was used. Each participant also completed one DLW measurement, with a subset having a repeat. PAEE was estimated by subtracting resting metabolic rate and the thermic effect of food from total daily energy expenditure estimated by DLW. Partial Spearman correlations were used to estimate associations between PAEE and each accelerometer metric. Correlations between the accelerometer metrics and DLW-determined PAEE were higher for triaxial counts than vertical axis counts. After adjusting for weight, age, accelerometer wear time, and fat free mass, the correlation between TAC per day based on triaxial counts and DLW-determined PAEE was 0.44 in women and 0.41 in men. Correlations for steps per day and accelerometer-estimated PAEE with DLW-determined PAEE were similar. After adjustment for within-person variation in DLW-determined PAEE, the correlations for TAC per day increased to 0.61 and 0.49, respectively. Correlations between MVPA and DLW-determined PAEE were lower, particularly for modified bouts of ≥10 min. Accelerometer measures that represent total activity volume, including TAC per day, steps per day, and PAEE, were more highly correlated with DLW-determined PAEE than MVPA using traditional thresholds and should be considered by researchers seeking to reduce accelerometer data to a single metric.

  13. The use of MP3 recorders to log data from equine hoof mounted accelerometers.

    PubMed

    Parsons, K J; Wilson, A M

    2006-11-01

    MP3 recorders are readily available, small, lightweight and low cost, providing the potential for logging analogue hoof mounted accelerometer signals for the characterisation of equine locomotion. These, however, require testing in practice. To test whether 1) multiple MP3 recorders can maintain synchronisation, giving the ability to synchronise independent recorders for the logging of multiple limbs simultaneously; and 2) features of a foot mounted accelerometer signal attributable to foot-on and foot-off can be accurately identified from horse foot mounted accelerometers logged directly into an MP3 recorder. Three experiments were performed: 1) Maintenance of synchronisation was assessed by counting the number of samples recorded by each of 4 MP3 recorders while mounted on a trotting horse and over 2 consecutive 30 min periods in 8 recorders on a bench. 2) Foot-on and foot-off times obtained from manual transcription of MP3 logged data and directly logged accelerometer signal were compared. 3) MP3/accelerometer acquisition units were used to log accelerometer signals from racehorses during extended training sessions. Mean absolute error of synchronisation between MP3 recorders was 10 samples per million (compared to mean number of samples, range 1-32 samples per million). Error accumulation showed a linear correlation with time. Features attributable to foot on and foot off were equally identifiable from the MP3 recorded signal over a range of equine gaits. Multiple MP3 recorders can be synchronised and used as a relatively cheap, robust, reliable and accurate logging system when combined with an accelerometer and external battery for the specific application of the measurement of stride timing variables across the range of equine gaits during field locomotion. Footfall timings can be used to identify intervals between the fore and hind contacts, the identification of diagonal advanced placement and to calculate stride timing variables (stance time, protraction time and stride time). These parameters are invaluable for the characterisation and assessment of equine locomotion.

  14. Criterion validity of the Physical Activity Questionnaire for Schoolchildren (PAQ-S) in assessing physical activity levels: the Healthy Growth Study.

    PubMed

    Manios, Y; Androutsos, O; Moschonis, G; Birbilis, M; Maragkopoulou, K; Giannopoulou, A; Argyri, E; Kourlaba, G

    2013-10-01

    The aim of this paper was to evaluate the criterion validity of the Physical Activity Questionnaire for Schoolchildren (PAQ-S). The current study is a subcohort of the Healthy Growth Study, a large-scale cross-sectional study. 202 schoolchildren aged 9-13 years from Greece completed the PAQ-S and wore an accelerometer for 4 consecutive days. Time spent moderate (MPA), moderate to vigorous (MVPA) and vigorous (VPA) physical activity was calculated based on PAQ-S and accelerometer data. The average time spent on MPA and MVPA as derived from PAQ-S and from accelerometers were significantly moderately correlated (r=0.462, P<0.001 and r=0.483, P<0.001, respectively). No significant correlation was detected between PAQ-S and accelerometer-measured time spent performing VPA (rho=0.150, P=0.057). Intraclass Correlation Coefficient (ICC) indicated a moderate agreement between PAQ-S and accelerometer in estimating MPA (ICC=0.592, P<0.001) and MVPA (ICC=0.581, P<0.001). Bland-Altman analysis revealed a small mean difference (the "bias"), between the two methods, in estimating MPA, although this difference was found to be significantly higher than zero ("bias"=27.4% of the accelerometer-measured mean score, P=0.006). On the other hand, Bland-Altman analysis revealed a large mean difference in estimating MVPA and VPA ("bias"=84.2% and 357% of the accelerometer-measured mean score for MVPA and VPA, respectively and P<0.001). The high correlation coefficient between the average and difference values between all physical activity scores derived from accelerometers and PAQ-S, indicate a systematic overestimation of physical activity time with increasing physical activity for PAQ-S. The validity of PAQ-S for the estimation of MPA and MVPA was found to be slightly similar self-reported measures for schoolchildren. Therefore, this questionnaire could be used as a tool for physical activity assessment in large population studies.

  15. Electrostatic Accelerometer for the Gravity Recovery and Climate Experiment Follow-On Mission (GRACE FO)

    NASA Astrophysics Data System (ADS)

    Perrot, Eddy; Christophe, Bruno; Foulon, Bernard; Boulanger, Damien; Liorzou, Françoise; Lebat, Vincent

    2013-04-01

    The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after substracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing and manufacturing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics and the Front-End Electronic Unit) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. Besides, a thermal stability is needed for the accelerometer core and front-end electronics to avoid bias and scale factor variation. To reach this stability, the sensor unit is enclosed in a thermal box designed by Astrium, spacecraft manufacturer. The accelerometers are designed to endure mechanical excitation especially due to launching vibrations. As the measure must be accurate, no displacements or sliding must appear during excitations. The electrode cage is made of glass material (ULE), which is very critical, in particular due to the free motion of the proof-mass during the launch. Specific analysis on this part is realized to ensure mechanical behavior. The design of electrostatic accelerometer of the GRACE Follow-On mission benefits of the GRACE heritage, GOCE launched in 2009 and MICROSCOPE which will be launched in 2016, including some improvement to win in performance, in particular the thermal sensitivity of the measurements.

  16. Navigation and guidance of Japanese deepspace probes encountering Halley's comet

    NASA Astrophysics Data System (ADS)

    Nishimura, T.; Matsuo, H.; Takano, T.; Kawaguchi, J.

    The techniques used by ISAS in the guidance of the Sakigake and Suisei probes, which encountered Comet Halley in March 1986, are reviewed. Consideration is given to the guidance of the last rocket stage in the direct ascent phase, midcourse maneuvers, tracking systems and communication links, the tracking strategy, trajectory-generation and orbit-determination software, and orbit-determination accuracy. Diagrams, drawings, graphs, photographs, and tables of numerical data are provided, and the ISAS positions of both probes during the first 10 days after launch are shown to be within 100 km in distance and 1 m/sec in velocity of NASA coordinate estimates.

  17. Application of a disturbance-rejection controller for robotic-enhanced limb rehabilitation trainings.

    PubMed

    Madoński, R; Kordasz, M; Sauer, P

    2014-07-01

    The paper presents an application of a special case of an Active Disturbance Rejection Controller (ADRC) in governing a proper realization of basic limb rehabilitation trainings. The experimental study is performed on a model of a flexible joint manipulator, whose behavior resembles a real robotic rehabilitation device. The multidimensional character of the considered assisting mechanism makes it a nontrivial modeling and control problem. However, by the use of the ADRC approach, the modeling uncertainty in the plant is partially decoupled from the system, which increases the robustness of the whole control framework against both internal and external disturbances. © 2013 ISA. Published by ISA. All rights reserved.

  18. Safety of Polysorbate 80 in the Oncology Setting.

    PubMed

    Schwartzberg, Lee S; Navari, Rudolph M

    2018-05-23

    Polysorbate 80 is a synthetic nonionic surfactant used as an excipient in drug formulation. Various products formulated with polysorbate 80 are used in the oncology setting for chemotherapy, supportive care, or prevention, including docetaxel, epoetin/darbepoetin, and fosaprepitant. However, polysorbate 80, like some other surfactants, is not an inert compound and has been implicated in a number of systemic and injection- and infusion-site adverse events (ISAEs). The current formulation of intravenous fosaprepitant has been associated with an increased risk of hypersensitivity systemic reactions (HSRs). Factors that have been associated with an increased risk of fosaprepitant-related ISAEs include the site of administration (peripheral vs. central venous), coadministration of anthracycline-based chemotherapy, number of chemotherapy cycles or fosaprepitant doses, and concentration of fosaprepitant administered. Recently, two polysorbate 80-free agents have been approved: intravenous rolapitant, which is a neurokinin 1 (NK-1) receptor antagonist formulated with the synthetic surfactant polyoxyl 15 hydroxystearate, and intravenous HTX-019, which is a novel NK-1 receptor antagonist free of synthetic surfactants. Alternative formulations will obviate the polysorbate 80-associated ISAEs and HSRs and should improve overall management of chemotherapy-induced nausea and vomiting.Funding Heron Therapeutics, Inc.

  19. A unified approach for debugging is-a structure and mappings in networked taxonomies

    PubMed Central

    2013-01-01

    Background With the increased use of ontologies and ontology mappings in semantically-enabled applications such as ontology-based search and data integration, the issue of detecting and repairing defects in ontologies and ontology mappings has become increasingly important. These defects can lead to wrong or incomplete results for the applications. Results We propose a unified framework for debugging the is-a structure of and mappings between taxonomies, the most used kind of ontologies. We present theory and algorithms as well as an implemented system RepOSE, that supports a domain expert in detecting and repairing missing and wrong is-a relations and mappings. We also discuss two experiments performed by domain experts: an experiment on the Anatomy ontologies from the Ontology Alignment Evaluation Initiative, and a debugging session for the Swedish National Food Agency. Conclusions Semantically-enabled applications need high quality ontologies and ontology mappings. One key aspect is the detection and removal of defects in the ontologies and ontology mappings. Our system RepOSE provides an environment that supports domain experts to deal with this issue. We have shown the usefulness of the approach in two experiments by detecting and repairing circa 200 and 30 defects, respectively. PMID:23548155

  20. Behavioural responses of spinner dolphins to human interactions.

    PubMed

    Fumagalli, Maddalena; Cesario, Amina; Costa, Marina; Harraway, John; Notarbartolo di Sciara, Giuseppe; Slooten, Elisabeth

    2018-04-01

    There is increasing evidence that whale and dolphin watching activities have detrimental effects on targeted cetacean populations. In Egypt, spinner dolphins regularly occur in the resting areas of Samadai, Satayah and Qubbat'Isa reefs. In-water human interactions with dolphins are regulated with a time-area closure system at Samadai, unregulated at Satayah and non-existent at Qubbat'Isa. This provided an ideal experimental setting to advance our understanding of the effects of tourism on a species highly sensitive to disturbances. Our study confirmed that the intensity and duration of interactions, and therefore, dolphin exposure to tourism, differed among the study sites. Compared with the Qubbat'Isa control site, behavioural reactions to boats and swimmers at the two tourism sites suggested that dolphin rest was disrupted, especially around the middle of the day and especially at Satayah, where dolphin tourism is unregulated. Our results indicate also that the dolphin protection measures at Samadai reduce the level of disturbance. We recommend that similar measures be implemented at other dolphin tourism locations, and that no new operations be initiated until the long-term impacts on dolphin populations are better understood. Our experience emphasizes the need to adopt precautionary approaches in research and management of whale and dolphin watching.

  1. Infrared sensor-based aerosol sanitization system for controlling Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes on fresh produce.

    PubMed

    Kim, Sang-Oh; Ha, Jae-Won; Park, Ki-Hwan; Chung, Myung-Sub; Kang, Dong-Hyun

    2014-06-01

    An economical aerosol sanitization system was developed based on sensor technology for minimizing sanitizer usage, while maintaining bactericidal efficacy. Aerosol intensity in a system chamber was controlled by a position-sensitive device and its infrared value range. The effectiveness of the infrared sensor-based aerosolization (ISA) system to inactivate Escherichia coli O157:H7, Salmonella Typhimurium, and Listeria monocytogenes on spinach leaf surfaces was compared with conventional aerosolization (full-time aerosol treated), and the amount of sanitizer consumed was determined after operation. Three pathogens artificially inoculated onto spinach leaf surfaces were treated with aerosolized peracetic acid (400 ppm) for 15, 30, 45, and 60 min at room temperature (22 ± 2°C). Using the ISA system, inactivation levels of the three pathogens were equal or better than treatment with conventional full-time aerosolization. However, the amount of sanitizer consumed was reduced by ca. 40% using the ISA system. The results of this study suggest that an aerosol sanitization system combined with infrared sensor technology could be used for transportation and storage of fresh produce efficiently and economically as a practical commercial intervention.

  2. Impact of Vancomycin MIC on Treatment Outcomes in Invasive Staphylococcus aureus Infections

    PubMed Central

    Song, Kyoung-Ho; Kim, Moonsuk; Kim, Chung Jong; Cho, Jeong Eun; Choi, Yun Jung; Park, Jeong Su; Ahn, Soyeon; Jang, Hee-Chang; Park, Kyung-Hwa; Jung, Sook-In; Yoon, Nara; Kim, Dong-Min; Hwang, Jeong-Hwan; Lee, Chang Seop; Lee, Jae Hoon; Kwak, Yee Gyung; Kim, Eu Suk; Park, Seong Yeon; Park, Yoonseon; Lee, Kkot Sil; Lee, Yeong-Seon

    2016-01-01

    ABSTRACT There are conflicting data on the association of vancomycin MIC (VAN-MIC) with treatment outcomes in Staphylococcus aureus infections. We investigated the relationship between high VAN-MIC and 30-day mortality and identified the risk factors for mortality in a large cohort of patients with invasive S. aureus (ISA) infections, defined as the isolation of S. aureus from a normally sterile site. Over a 2-year period, 1,027 adult patients with ISA infections were enrolled in 10 hospitals, including 673 (66%) patients with methicillin-resistant S. aureus (MRSA) infections. There were 200 (19.5%) isolates with high VAN-MIC (≥1.5 mg/liter) by Etest and 87 (8.5%) by broth microdilution (BMD). The all-cause 30-day mortality rate was 27.4%. High VAN-MIC by either method was not associated with all-cause 30-day mortality, and this finding was consistent across MIC methodologies and methicillin susceptibilities. We conclude that high VAN-MIC is not associated with increased risk of all-cause 30-day mortality in ISA infections. Our data support the view that VAN-MIC alone is not sufficient evidence to change current clinical practice. PMID:27956430

  3. International Solar Terrestrial Physics (ISTP) geotail mission

    NASA Technical Reports Server (NTRS)

    Sanford, R.; Sizemore, K. O.

    1991-01-01

    The Geotail spacecraft will be provided by the Institute of Space and Astronautical Science (ISAS) and will provide a Delta Launch Vehicle, tracking support by the Deep Space Network (DSN), and data processing support by GSFC. In exchange, ISAS will reserve part of the payload for NASA instruments together with a certain number of investigators from the United States. As the solar wind flows toward the Earth, some of the energy is modified by the Earth's magnetosphere, ionosphere, and upper atmosphere. This interaction causes the flow to be altered, creating a plasmasphere, plasma sheet, and ring currents in the Earth's Geomagnetic Tail region. The result is a series of distinct regions which affect processes on the Earth. By traversing the tail region to a variety of depths, Geotail will be able to determine the size, position, and other properties of these regions. When correlated with information obtained from the other ISAS spacecraft, Geotail data should help to provide a more complete understanding of how the solar processes affect the Earth's environment. The flight profile is given, and information is presented in tabular form on the following topics: DSN support, frequency assignments, telemetry, command, and tracking support responsibility.

  4. [Outpatient external dacryocystorhinostomy under regional anesthesia and sedation].

    PubMed

    Benatar-Haserfaty, J; Monleón de la Calle, M P; Sanz-López, A; Muriel García, A

    2007-01-01

    To assess the rate of early complications of outpatient external dacryocystorhinostomy (DCR) and patient satisfaction with the anesthetic technique. This prospective study enrolled 58 patients undergoing external DCR. We analyzed demographic variables, ASA physical status, level of sedation achieved, postoperative pain, systemic complications, intraoperative bleeding, duration of surgery, time until discharge home, and patient and surgeon satisfaction with the anesthetic technique. The mean (SD) level of satisfaction was 4.85 (0.80) points on the Iowa Satisfaction With Anesthesia Scale (ISAS). A positive association was found between postoperative pain and a lower ISAS score. There was also a positive association between use of rescue analgesia in the early postoperative period and a lower ISAS score. Mean blood loss per procedure was 178.9 (108.2) mL. The rate of minor systemic complications was 15.5%. The surgeon's rating of conditions in the surgical field was excellent or good in 89.6% of the cases. External DCR can be performed on an outpatient basis within a reasonable safety margin and with a low early postoperative complication rate. Patient satisfaction with anesthesia was high. Provision of preoperative information about the meaning of sedation, postoperative analgesia, and surgical bleeding are aspects to improve in this practice setting.

  5. Towards Integrated Marmara Strong Motion Network

    NASA Astrophysics Data System (ADS)

    Durukal, E.; Erdik, M.; Safak, E.; Ansal, A.; Ozel, O.; Alcik, H.; Mert, A.; Kafadar, N.; Korkmaz, A.; Kurtulus, A.

    2009-04-01

    Istanbul has a 65% chance of having a magnitude 7 or above earthquake within the next 30 years. As part of the preparations for the future earthquake, strong motion networks have been installed in and around Istanbul. The Marmara Strong Motion Network, operated by the Department of Earthquake Engineering of Kandilli Observatory and Earthquake Research Institute, encompasses permanent systems outlined below. It is envisaged that the networks will be run by a single entity responsible for technical management and maintanence, as well as for data management, archiving and dissemination through dedicated web-based interfaces. • Istanbul Earthquake Rapid Response and Early Warning System - IERREWS (one hundred 18-bit accelerometers for rapid response; ten 24-bit accelerometers for early warning) • IGDAŞ Gas Shutoff Network (100 accelerometers to be installed in 2010 and integrated with IERREWS) • Structural Monitoring Arrays - Fatih Sultan Mehmet Suspension Bridge (1200m-long suspension bridge across the Bosphorus, five 3-component accelerometers + GPS sensors) - Hagia Sophia Array (1500-year-old historical edifice, 9 accelerometers) - Süleymaniye Mosque Array (450-year-old historical edifice,9 accelerometers) - Fatih Mosque Array (237-year-old historical edifice, 9 accelerometers) - Kanyon Building Array (high-rise office building, 5 accelerometers) - Isbank Tower Array (high-rise office building, 5 accelerometers) - ENRON Array (power generation facility, 4 acelerometers) - Mihrimah Sultan Mosque Array (450-year-old historical edifice,9 accelerometers + tiltmeters, to be installed in 2009) - Sultanahmet Mosque Array, (390-year-old historical edifice, 9 accelerometers + tiltmeters, to be installed in 2009) • Special Arrays - Atakoy Vertical Array (four 3-component accelerometers at 25, 50, 75, and 150 m depths) - Marmara Tube Tunnel (1400 m long submerged tunnel, 128 ch. accelerometric data, 24 ch. strain data, to be installed in 2010) - Air-Force Academy Array (72 ch. dense accelerometric array to be installed in 2010) - Gemlik Array (a dense basin array of 8 stations, to be installed in 2010) The objectives of these systems and networks are: (1) to produce rapid earthquake intensity, damage and loss assessment information after an earthquake (in the case of IERREWS), (2) to monitor conditions of structural systems, (3) to develop real-time data processing, analysis, and damage detection and location tools (in the case of structural networks) after an extreme event, (4) to assess spatial properties of strong ground motion and ground strain, and to characterise basin response (in the case of special arrays), (5) to investigate site response and wave propagation (in the case of vertical array). Ground motion data obtained from these strong motion networks have and are being used for investigations of attenuation, spatial variation (coherence), simulation benchmarking, source modeling, site response, seismic microzonation, system identification and structural model verification and structural health control. In addition to the systems and networks outlined above there are two temporary networks: KIMNET - a dense urban noise and microtremor network consisting of 50 broadband stations expected to be operational in mid 2009, and SOSEWIN - a 20-station, self-organizing structural integrated array at Ataköy in Istanbul.

  6. Different grades MEMS accelerometers error characteristics

    NASA Astrophysics Data System (ADS)

    Pachwicewicz, M.; Weremczuk, J.

    2017-08-01

    The paper presents calibration effects of two different MEMS accelerometers of different price and quality grades and discusses different accelerometers errors types. The calibration for error determining is provided by reference centrifugal measurements. The design and measurement errors of the centrifuge are discussed as well. It is shown that error characteristics of the sensors are very different and it is not possible to use simple calibration methods presented in the literature in both cases.

  7. Theoretical analysis and concept demonstration of a novel MOEMS accelerometer based on Raman—Nath diffraction

    NASA Astrophysics Data System (ADS)

    Zuwei, Zhang; Zhiyu, Wen; Jing, Hu

    2012-04-01

    The design and simulation of a novel microoptoelectromechanical system (MOEMS) accelerometer based on Raman—Nath diffraction are presented. The device is planned to be fabricated by microelectromechanical system technology and has a different sensing principle than the other reported MOEMS accelerometers. The fundamental theories and principles of the device are discussed in detail, a 3D finite element simulation of the flexural plate wave delay line oscillator is provided, and the operation frequency around 40 MHz is calculated. Finally, a lecture experiment is performed to demonstrate the feasibility of the device. This novel accelerometer is proposed to have the advantages of high sensitivity and anti-radiation, and has great potential for various applications.

  8. Acceleration Recorder and Playback Module

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1996-01-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  9. Acceleration recorder and playback module

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1994-11-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  10. Acceleration recorder and playback module

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J., Jr.

    1992-09-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  11. Acceleration recorder and playback module

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1994-01-01

    The present invention is directed to methods and apparatus relating to an accelerometer electrical signal recorder and playback module. The recorder module may be manufactured in lightweight configuration and includes analog memory components to store data. Signal conditioning circuitry is incorporated into the module so that signals may be connected directly from the accelerometer to the recorder module. A battery pack may be included for powering both the module and the accelerometer. Timing circuitry is included to control the time duration within which data is recorded or played back so as to avoid overloading the analog memory components. Multiple accelerometer signal recordings may be taken simultaneously without analog to digital circuits, multiplexing circuitry or software to compensate for the effects of multiplexing the signals.

  12. Method and apparatus for measuring the mass flow rate of a fluid

    DOEpatents

    Evans, Robert P.; Wilkins, S. Curtis; Goodrich, Lorenzo D.; Blotter, Jonathan D.

    2002-01-01

    A non invasive method and apparatus is provided to measure the mass flow rate of a multi-phase fluid. An accelerometer is attached to a pipe carrying a multi-phase fluid. Flow related measurements in pipes are sensitive to random velocity fluctuations whose magnitude is proportional to the mean mass flow rate. An analysis of the signal produced by the accelerometer shows a relationship between the mass flow of a fluid and the noise component of the signal of an accelerometer. The noise signal, as defined by the standard deviation of the accelerometer signal allows the method and apparatus of the present invention to non-intrusively measure the mass flow rate of a multi-phase fluid.

  13. Simultaneous processing of photographic and accelerator array data from sled impact experiment

    NASA Astrophysics Data System (ADS)

    Ash, M. E.

    1982-12-01

    A Quaternion-Kalman filter model is derived to simultaneously analyze accelerometer array and photographic data from sled impact experiments. Formulas are given for the quaternion representation of rotations, the propagation of dynamical states and their partial derivatives, the observables and their partial derivatives, and the Kalman filter update of the state given the observables. The observables are accelerometer and tachometer velocity data of the sled relative to the track, linear accelerometer array and photographic data of the subject relative to the sled, and ideal angular accelerometer data. The quaternion constraints enter through perfect constraint observations and normalization after a state update. Lateral and fore-aft impact tests are analyzed with FORTRAN IV software written using the formulas of this report.

  14. Description of the three axis low-g accelerometer package

    NASA Technical Reports Server (NTRS)

    Amalavage, A. J.; Fikes, E. H.; Berry, E. H.

    1978-01-01

    The three axis low-g accelerometer package designed for use on the Space Processing Application Rocket (SPAR) Program is described. The package consists of the following major sections: (1) three Kearfott model 2412 accelerometers mounted in an orthogonal triad configuration on a temperature controlled, thermally isolated cube, (2) the accelerometer servoelectronics (printed circuit cards PC-6 through PC-12), and (3) the signal conditioner (printed circuit cards PC-15 and PC-16). The measurement range is 0 + or - 0.031 g with a quantization of 1.1 x 10 to the 7th power g. The package was flown successfully on six SPAR launches with the Black Brant booster. These flights provide approximately 300 s of free fall or zero-g environment.

  15. Validation of parent-reported physical activity and sedentary time by accelerometry in young children.

    PubMed

    Sarker, Hrishov; Anderson, Laura N; Borkhoff, Cornelia M; Abreo, Kathleen; Tremblay, Mark S; Lebovic, Gerald; Maguire, Jonathon L; Parkin, Patricia C; Birken, Catherine S

    2015-11-30

    It is unknown if young children's parent-reported physical activity and sedentary time are correlated with direct measures. The study objectives were to compare parent-reported physical and sedentary activity versus directly measured accelerometer data in early childhood. From 2013 to 2014, 117 healthy children less than 6 years of age were recruited to wear Actical accelerometers for 7 days. Accelerometer data and questionnaires were available on 87 children (74%). Average daily physical activity was defined as the sum of activity ≥100 counts per minute, and sedentary time as the sum of activity <100 counts per minute during waking hours. Parents reported daily physical activity (unstructured free play in and out of school, and organized activities) and selected sedentary behaviors (screen time, stroller time, time in motor vehicle). Spearman correlation coefficients and Bland-Altman plots were used to assess the validity of parent-reported measures compared to accelerometer data. Total physical activity was significantly greater when measured by accelerometer than parent-report; the median difference was 131 min/day (p < 0.001). Parent-reported child physical activity was weak to moderately correlated with directly measured total physical activity (r = 0.39, 95% CI 0.19, 0.56). The correlations between types of physical activity (unstructured free play in and outside of school/daycare, and organized structured activity) and accelerometer were r = 0.30 (95% CI 0.09, 0.49); r = 0.42 (95% CI 0.23, 0.58); r = 0.26 (95% CI 0.05, 0.46), respectively. There was no correlation between parent-reported and accelerometer-measured total sedentary time in children (r = 0.10, 95% CI -0.12, 0.33). When the results were stratified by age group (<18, 18-47, and 48-70 months of age) no statistically significant correlations were observed and some inverse associations were observed. The correlation between parent-report of young children's physical activity and accelerometer-measured activity was weak to moderate depending on type of activity and age group. Parent-report of children's sedentary time was not correlated with accelerometer-measured sedentary time. Additional validation studies are needed to determine if parent-reported measures of physical activity and sedentary time are valid among children less than 6 years of age and across these young age groups.

  16. Validity of the International Physical Activity Questionnaire and the Singapore Prospective Study Program physical activity questionnaire in a multiethnic urban Asian population.

    PubMed

    Nang, Ei Ei Khaing; Gitau Ngunjiri, Susan Ayuko; Wu, Yi; Salim, Agus; Tai, E Shyong; Lee, Jeannette; Van Dam, Rob M

    2011-10-13

    Physical activity patterns of a population remain mostly assessed by the questionnaires. However, few physical activity questionnaires have been validated in Asian populations. We previously utilized a combination of different questionnaires to assess leisure time, transportation, occupational and household physical activity in the Singapore Prospective Study Program (SP2). The International Physical Activity Questionnaire (IPAQ) has been developed for a similar purpose. In this study, we compared estimates from these two questionnaires with an objective measure of physical activity in a multi-ethnic Asian population. Physical activity was measured in 152 Chinese, Malay and Asian Indian adults using an accelerometer over five consecutive days, including a weekend. Participants completed both the physical activity questionnaire in SP2 (SP2PAQ) and IPAQ long form. 43 subjects underwent a second set of measurements on average 6 months later to assess reproducibility of the questionnaires and the accelerometer measurements. Spearman correlations were used to evaluate validity and reproducibility and correlations for validity were corrected for within-person variation of accelerometer measurements. Agreement between the questionnaires and the accelerometer measurements was also evaluated using Bland Altman plots. The corrected correlation with accelerometer estimates of energy expenditure from physical activity was better for the SP2PAQ (vigorous activity: r = 0.73; moderate activity: r = 0.27) than for the IPAQ (vigorous activity: r = 0.31; moderate activity: r = 0.15). For moderate activity, the corrected correlation between SP2PAQ and the accelerometer was higher for Chinese (r = 0.38) and Malays (r = 0.57) than for Indians (r = -0.09). Both questionnaires overestimated energy expenditure from physical activity to a greater extent at higher levels of physical activity than at lower levels of physical activity. The reproducibility for moderate activity (accelerometer: r = 0.68; IPAQ: r = 0.58; SP2PAQ: r = 0.55) and vigorous activity (accelerometer: 0.52; IPAQ: r = 0.38; SP2PAQ: r = 0.75) was moderate to high for all instruments. The agreement between IPAQ and accelerometer measurements of energy expenditure from physical activity was poor in our Asian study population. The SP2PAQ showed good validity and reproducibility for vigorous activity, but performed less well for moderate activity particularly in Indians. Further effort is needed to develop questionnaires that better capture moderate activity in Asian populations.

  17. Characterizing coarse bedload transport during floods with RFID and accelerometer tracers, in-stream RFID antennas and HEC-RAS modeling

    NASA Astrophysics Data System (ADS)

    Olinde, L.; Johnson, J. P.

    2013-12-01

    By monitoring the transport timing and distances of tracer grains in a steep mountains stream, we collected data that can constrain numerical bedload transport models considered for these systems. We captured bedload activity during a weeks-spanning snowmelt period in Reynolds Creek, Idaho by deploying Radio Frequency Identification (RFID) and accelerometer embedded tracers with in-stream stationary RFID antennas. During transport events, RFID dataloggers recorded the times when tracers passed over stationary antennas. The accelerometer tracers also logged x, y, z-axis accelerations every 10 minutes to identify times of motion and rest. After snowmelt flows receded, we found tracers with mobile antennas and surveyed their positions. We know the timing and tracer locations when accelerometer tracers were initially entrained, passed stationary antennas, and were finally deposited at the surveyed locations. The fraction of moving accelerometers over time correlates well with discharge. Comparisons of the transported tracer fraction between rising and falling limbs over multiple flood peaks suggest that some degree of clockwise hysteresis persisted during the snowmelt period. Additionally, we apply accelerometer transport durations and displacement distances to calculate virtual velocities over full tracer path lengths and over lengths between initial locations to stationary antennas as well as between stationary antennas to final positions. The accelerometer-based virtual velocities are significantly faster than those estimated from traditional tracer methods that estimate bedload transport durations by assuming threshold flow conditions. We also subsample the motion data to calculate how virtual velocities change over the measurement intervals. Regressions of these relations are in turn used to extrapolate virtual velocities at smaller sampling timescales. Minimum hop lengths are also evaluated for each accelerometer tracer. Finally, flow conditions during the snowmelt hydrograph are modeled over the 11 kilometers of surveyed stream by utilizing 1m airborne LiDAR and HEC-GeoRAS. Cross-sectional HEC-RAS results are used to estimate the spatial distribution of longitudinal shear velocities over the observed discharges. At final accelerometer tracer positions, we analyze the HEC-RAS generated flow conditions for each disentrainment discharge magnitude. The techniques developed here have the potential to link individual grain characteristics during floods to a range of time and length scales.

  18. Movement, resting, and attack behaviors of wild pumas are revealed by tri-axial accelerometer measurements.

    PubMed

    Wang, Yiwei; Nickel, Barry; Rutishauser, Matthew; Bryce, Caleb M; Williams, Terrie M; Elkaim, Gabriel; Wilmers, Christopher C

    2015-01-01

    Accelerometers are useful tools for biologists seeking to gain a deeper understanding of the daily behavior of cryptic species. We describe how we used GPS and tri-axial accelerometer (sampling at 64 Hz) collars to monitor behaviors of free-ranging pumas (Puma concolor), which are difficult or impossible to observe in the wild. We attached collars to twelve pumas in the Santa Cruz Mountains, CA from 2010-2012. By implementing Random Forest models, we classified behaviors in wild pumas based on training data from observations and measurements of captive puma behavior. We applied these models to accelerometer data collected from wild pumas and identified mobile and non-mobile behaviors in captive animals with an accuracy rate greater than 96%. Accuracy remained above 95% even after downsampling our accelerometer data to 16 Hz. We were further able to predict low-acceleration movement behavior (e.g. walking) and high-acceleration movement behavior (e.g. running) with 93.8% and 92% accuracy, respectively. We had difficulty predicting non-movement behaviors such as feeding and grooming due to the small size of our training dataset. Lastly, we used model-predicted and field-verified predation events to quantify acceleration characteristics of puma attacks on large prey. These results demonstrate that accelerometers are useful tools for classifying the behaviors of cryptic medium and large-sized terrestrial mammals in their natural habitats and can help scientists gain deeper insight into their fine-scale behavioral patterns. We also show how accelerometer measurements can provide novel insights on the energetics and predation behavior of wild animals. Lastly we discuss the conservation implications of identifying these behavioral patterns in free-ranging species as natural and anthropogenic landscape features influence animal energy allocation and habitat use.

  19. Extracting Time-Accurate Acceleration Vectors From Nontrivial Accelerometer Arrangements.

    PubMed

    Franck, Jennifer A; Blume, Janet; Crisco, Joseph J; Franck, Christian

    2015-09-01

    Sports-related concussions are of significant concern in many impact sports, and their detection relies on accurate measurements of the head kinematics during impact. Among the most prevalent recording technologies are videography, and more recently, the use of single-axis accelerometers mounted in a helmet, such as the HIT system. Successful extraction of the linear and angular impact accelerations depends on an accurate analysis methodology governed by the equations of motion. Current algorithms are able to estimate the magnitude of acceleration and hit location, but make assumptions about the hit orientation and are often limited in the position and/or orientation of the accelerometers. The newly formulated algorithm presented in this manuscript accurately extracts the full linear and rotational acceleration vectors from a broad arrangement of six single-axis accelerometers directly from the governing set of kinematic equations. The new formulation linearizes the nonlinear centripetal acceleration term with a finite-difference approximation and provides a fast and accurate solution for all six components of acceleration over long time periods (>250 ms). The approximation of the nonlinear centripetal acceleration term provides an accurate computation of the rotational velocity as a function of time and allows for reconstruction of a multiple-impact signal. Furthermore, the algorithm determines the impact location and orientation and can distinguish between glancing, high rotational velocity impacts, or direct impacts through the center of mass. Results are shown for ten simulated impact locations on a headform geometry computed with three different accelerometer configurations in varying degrees of signal noise. Since the algorithm does not require simplifications of the actual impacted geometry, the impact vector, or a specific arrangement of accelerometer orientations, it can be easily applied to many impact investigations in which accurate kinematics need to be extracted from single-axis accelerometer data.

  20. Microelectromechanical systems (MEMS) sensors based on lead zirconate titanate (PZT) films

    NASA Astrophysics Data System (ADS)

    Wang, Li-Peng

    2001-12-01

    In this thesis, modeling, fabrication and testing of microelectromechanical systems (MEMS) accelerometers based on piezoelectric lead zirconate titanate (PZT) films are investigated. Three different types of structures, cantilever beam, trampoline, and annular diaphragm, are studied. It demonstrates the high-performance, miniaturate, mass-production-compatible, and potentially circuitry-integratable piezoelectric-type PZT MEMS devices. Theoretical models of the cantilever-beam and trampoline accelerometers are derived via structural dynamics and the constitutive equations of piezoelectricity. The time-dependent transverse vibration equations, mode shapes, resonant frequencies, and sensitivities of the accelerometers are calculated through the models. Optimization of the silicon and PZT thickness is achieved with considering the effects of the structural dynamics, the material properties, and manufacturability for different accelerometer specifications. This work is the first demonstration of the fabrication of bulk-micromachined accelerometers combining a deep-trench reactive ion etching (DRIE) release strategy and thick piezoelectric PZT films deposited using a sol-gel method. Processing challenges which are overcome included materials compatibility, metallization, processing of thick layers, double-side processing, deep-trench silicon etching, post-etch cleaning and process integration. In addition, the processed PZT films are characterized by dielectric, ferroelectric (polarization electric-field hysteresis), and piezoelectric measurements and no adverse effects are found. Dynamic frequency response and impedance resonance measurements are performed to ascertain the performance of the MEMS accelerometers. The results show high sensitivities and broad frequency ranges of the piezoelectric-type PZT MEMS accelerometers; the sensitivities range from 0.1 to 7.6 pC/g for resonant frequencies ranging from 44.3 kHz to 3.7 kHz. The sensitivities were compared to theoretical values and a reasonable agreement (˜36% difference) is obtained.

  1. Fiber Optic Laser Accelerometer

    DTIC Science & Technology

    2007-11-06

    embodiment of a fiber laser accelerometer 10. The fiber laser accelerometer 10 includes a fiber laser 12. Fiber laser 12 can be either a Fabry - Perot type...cavity fiber laser or a distributed feedback fiber laser. In a 4 Attorney Docket No. 97966 Fabry - Perot type fiber laser, the laser cavity is a length...type of signal. A receiver 26 receives the phase shifted signal. Receiver 26 is capable of demodulating and detecting the signal from the fiber laser by

  2. Comparison of the performance of the activPAL Professional physical activity logger to a discrete accelerometer-based activity monitor.

    PubMed

    Godfrey, A; Culhane, K M; Lyons, G M

    2007-10-01

    The aim of this study was to assess the accuracy of the 'activPAL Professional' physical activity logger by comparing its output to that of a proven discrete accelerometer-based activity monitor during extended measurements on healthy subjects while performing activities of daily living (ADL). Ten healthy adults, with unrestricted mobility, wore both the activPAL and the discrete dual accelerometer (Analog Devices ADXL202)-based activity monitor that recorded in synchronization with each other. The accelerometer derived data were then compared to that generated by the activPAL and a complete statistical and error analysis was performed using a Matlab program. This program determined trunk and thigh inclination angles to distinguish between sitting/lying, standing and stepping for the discrete accelerometer device and amount of time spent on each activity. Analysis was performed on a second-by-second basis and then categorized at 15s intervals in direct comparison with the activPAL generated data. Of the total time monitored (approximately 60 h) the detection accuracies for static and dynamic activities were approximately 98%. In a population of healthy adults, the data obtained from the activPAL Professional physical activity logger for both static and dynamic activities showed a close match to a proven discrete accelerometer data with an offset of approximately 2% between the two systems.

  3. Evaluation of MEMS-Based Wireless Accelerometer Sensors in Detecting Gear Tooth Faults in Helicopter Transmissions

    NASA Technical Reports Server (NTRS)

    Lewicki, David George; Lambert, Nicholas A.; Wagoner, Robert S.

    2015-01-01

    The diagnostics capability of micro-electro-mechanical systems (MEMS) based rotating accelerometer sensors in detecting gear tooth crack failures in helicopter main-rotor transmissions was evaluated. MEMS sensors were installed on a pre-notched OH-58C spiral-bevel pinion gear. Endurance tests were performed and the gear was run to tooth fracture failure. Results from the MEMS sensor were compared to conventional accelerometers mounted on the transmission housing. Most of the four stationary accelerometers mounted on the gear box housing and most of the CI's used gave indications of failure at the end of the test. The MEMS system performed well and lasted the entire test. All MEMS accelerometers gave an indication of failure at the end of the test. The MEMS systems performed as well, if not better, than the stationary accelerometers mounted on the gear box housing with regards to gear tooth fault detection. For both the MEMS sensors and stationary sensors, the fault detection time was not much sooner than the actual tooth fracture time. The MEMS sensor spectrum data showed large first order shaft frequency sidebands due to the measurement rotating frame of reference. The method of constructing a pseudo tach signal from periodic characteristics of the vibration data was successful in deriving a TSA signal without an actual tach and proved as an effective way to improve fault detection for the MEMS.

  4. A Novel Controller Design for the Next Generation Space Electrostatic Accelerometer Based on Disturbance Observation and Rejection.

    PubMed

    Li, Hongyin; Bai, Yanzheng; Hu, Ming; Luo, Yingxin; Zhou, Zebing

    2016-12-23

    The state-of-the-art accelerometer technology has been widely applied in space missions. The performance of the next generation accelerometer in future geodesic satellites is pushed to 8 × 10 - 13 m / s 2 / H z 1 / 2 , which is close to the hardware fundamental limit. According to the instrument noise budget, the geodesic test mass must be kept in the center of the accelerometer within the bounds of 56 pm / Hz 1 / 2 by the feedback controller. The unprecedented control requirements and necessity for the integration of calibration functions calls for a new type of control scheme with more flexibility and robustness. A novel digital controller design for the next generation electrostatic accelerometers based on disturbance observation and rejection with the well-studied Embedded Model Control (EMC) methodology is presented. The parameters are optimized automatically using a non-smooth optimization toolbox and setting a weighted H-infinity norm as the target. The precise frequency performance requirement of the accelerometer is well met during the batch auto-tuning, and a series of controllers for multiple working modes is generated. Simulation results show that the novel controller could obtain not only better disturbance rejection performance than the traditional Proportional Integral Derivative (PID) controllers, but also new instrument functions, including: easier tuning procedure, separation of measurement and control bandwidth and smooth control parameter switching.

  5. Characterizing performance of ultra-sensitive accelerometers

    NASA Technical Reports Server (NTRS)

    Sebesta, Henry

    1990-01-01

    An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.

  6. Validation of Questionnaire-Assessed Physical Activity in Comparison With Objective Measures Using Accelerometers and Physical Performance Measures Among Community-Dwelling Adults Aged ≥85 Years in Tokyo, Japan.

    PubMed

    Oguma, Yuko; Osawa, Yusuke; Takayama, Michiyo; Abe, Yukiko; Tanaka, Shigeho; Lee, I-Min; Arai, Yasumichi

    2017-04-01

    To date, there is no physical activity (PA) questionnaire with convergent and construct validity for the oldest-old. The aim of the current study was to investigate the validity of questionnaire-assessed PA in comparison with objective measures determined by uniaxial and triaxial accelerometers and physical performance measures in the oldest-old. Participants were 155 elderly (mean age 90 years) who were examined at the university and agreed to wear an accelerometer for 7 days in the 3-year-follow-up survey of the Tokyo Oldest-Old Survey of Total Health. Fifty-nine participants wore a uniaxial and triaxial accelerometer simultaneously. Self-rated walking, exercise, and household PA were measured using a modified Zutphen PA Questionnaire (PAQ). Several physical performance tests were done, and the associations among PAQ, accelerometer-assessed PA, and physical performances were compared by Spearman's correlation coefficients. Significant, low to moderate correlations between PA measures were seen on questionnaire and accelerometer assessments (ρ = 0.19 to 0.34). Questionnaireassessed PA measure were correlated with a range of lower extremity performance (ρ = 0.21 to 0.29). This PAQ demonstrated convergent and construct validity. Our findings suggest that the PAQ can reasonably be used in this oldest-old population to rank their PA level.

  7. A Novel Controller Design for the Next Generation Space Electrostatic Accelerometer Based on Disturbance Observation and Rejection

    PubMed Central

    Li, Hongyin; Bai, Yanzheng; Hu, Ming; Luo, Yingxin; Zhou, Zebing

    2016-01-01

    The state-of-the-art accelerometer technology has been widely applied in space missions. The performance of the next generation accelerometer in future geodesic satellites is pushed to 8×10−13m/s2/Hz1/2, which is close to the hardware fundamental limit. According to the instrument noise budget, the geodesic test mass must be kept in the center of the accelerometer within the bounds of 56 pm/Hz1/2 by the feedback controller. The unprecedented control requirements and necessity for the integration of calibration functions calls for a new type of control scheme with more flexibility and robustness. A novel digital controller design for the next generation electrostatic accelerometers based on disturbance observation and rejection with the well-studied Embedded Model Control (EMC) methodology is presented. The parameters are optimized automatically using a non-smooth optimization toolbox and setting a weighted H-infinity norm as the target. The precise frequency performance requirement of the accelerometer is well met during the batch auto-tuning, and a series of controllers for multiple working modes is generated. Simulation results show that the novel controller could obtain not only better disturbance rejection performance than the traditional Proportional Integral Derivative (PID) controllers, but also new instrument functions, including: easier tuning procedure, separation of measurement and control bandwidth and smooth control parameter switching. PMID:28025534

  8. Self-Reported Versus Accelerometer-Assessed Daily Physical Activity in Childhood Obesity Treatment.

    PubMed

    Schnurr, Theresia M; Bech, Bianca; Nielsen, Tenna R H; Andersen, Ida G; Hjorth, Mads F; Aadahl, Mette; Fonvig, Cilius E; Hansen, Torben; Holm, Jens-Christian

    2017-08-01

    We investigated the relationship between interview-based subjective ratings of physical activity (PA) engagement and accelerometer-assessed objectively measured PA in children and adolescents with overweight or obesity. A total of 92 children and adolescents (40 males, 52 females) with BMI ≥ 90th percentile for sex and age, aged 5-17 years had valid GT3X + accelerometer-assessed PA and interview-assessed self-reported information on PA engagement at the time of enrollment in a multidisciplinary outpatient tertiary treatment for childhood obesity. Accelerometer-derived mean overall PA and time spent in moderate to vigorous physical intensity were generated, applying cut-offs based on Vector Magnitude settings as defined by Romanzini et al. (2014), and a physical activity score (PAS) based on self-reported data. Overall, a higher self-reported PAS was correlated with higher accelerometer-assessed daily total PA levels ( r = 0.34, p < .01) and children who reported a high PAS were more physically active compared with children who reported a low PAS. There was a fair level of agreement between self-reported PAS and accelerometer-assessed PA (Kappa agreement = 0.23; 95% CI = [0.03, 0.43]; p = .01). PAS, derived from self-report, may be a useful instrument for evaluating PA at a group level among children and adolescents enrolled in multidisciplinary obesity treatment.

  9. Physical inactivity, neurological disability, and cardiorespiratory fitness in multiple sclerosis.

    PubMed

    Motl, R W; Goldman, M

    2011-02-01

    We examined the associations among physical activity, neurological disability, and cardiorespiratory fitness in two studies of individuals with multiple sclerosis (MS). Study 1 included 25 women with relapsing-remitting MS (RRMS) who undertook an incremental exercise test for measuring peak oxygen (VO₂(peak) ) consumption, wore an accelerometer during a 7-day period, and completed the Godin Leisure-Time Exercise Questionnaire (GLTEQ). Study 2 was a follow-up of Study 1 and included 24 women with RRMS who completed the self-reported Expanded Disability Status Scale (EDSS), undertook an incremental exercise test, wore an accelerometer during a 7-day period, and completed the GLTEQ. Study 1 indicated that VO₂(peak) was significantly correlated with accelerometer counts (pr = 0.69) and GLTEQ scores (pr = 0.63) even after controlling for age and MS duration. Study 2 indicated that VO₂(peak) was significantly correlated with accelerometer counts (pr = 0.50), GLTEQ scores (pr = 0.59), and EDSS scores (pr = -0.43) even after controlling for age and MS duration; there was a moderate partial correlation between accelerometer counts and EDSS scores (pr = -0.43). Multiple linear regression analysis indicated that both accelerometer counts (β = 0.32) and EDSS scores (β = -0.40) had statistically significant associations with VO₂(peak). The findings indicate that physical inactivity and neurological disability might represent independent risk factors for reduced levels of cardiorespiratory fitness in this population. © 2010 John Wiley & Sons A/S.

  10. Evaluation of two-dimensional accelerometers to monitor behavior of beef calves after castration.

    PubMed

    White, Brad J; Coetzee, Johann F; Renter, David G; Babcock, Abram H; Thomson, Daniel U; Andresen, Daniel

    2008-08-01

    To determine the accuracy of accelerometers for measuring behavior changes in calves and to determine differences in beef calf behavior from before to after castration. 3 healthy Holstein calves and 12 healthy beef calves. 2-dimensional accelerometers were placed on 3 calves, and data were logged simultaneous to video recording of animal behavior. Resulting data were used to generate and validate predictive models to classify posture (standing or lying) and type of activity (standing in place, walking, eating, getting up, lying awake, or lying sleeping). The algorithms developed were used to conduct a prospective trial to compare calf behavior in the first 24 hours after castration (n = 6) with behavior of noncastrated control calves (6) and with presurgical readings from the same castrated calves. On the basis of the analysis of the 2-dimensional accelerometer signal, posture was classified with a high degree of accuracy (98.3%) and the specific activity was estimated with a reasonably low misclassification rate (23.5%). Use of the system to compare behavior after castration revealed that castrated calves spent a significantly larger amount of time standing (82.2%), compared with presurgical readings (46.2%). 2-dimensional accelerometers provided accurate classification of posture and reasonable classification of activity. Applying the system in a castration trial illustrated the usefulness of accelerometers for measuring behavioral changes in individual calves.

  11. Application of Accelerometer Data to Mars Odyssey Aerobraking and Atmospheric Modeling

    NASA Technical Reports Server (NTRS)

    Tolson, R. H.; Keating, G. M.; George, B. E.; Escalera, P. E.; Werner, M. R.; Dwyer, A. M.; Hanna, J. L.

    2002-01-01

    Aerobraking was an enabling technology for the Mars Odyssey mission even though it involved risk due primarily to the variability of the Mars upper atmosphere. Consequently, numerous analyses based on various data types were performed during operations to reduce these risk and among these data were measurements from spacecraft accelerometers. This paper reports on the use of accelerometer data for determining atmospheric density during Odyssey aerobraking operations. Acceleration was measured along three orthogonal axes, although only data from the component along the axis nominally into the flow was used during operations. For a one second count time, the RMS noise level varied from 0.07 to 0.5 mm/s2 permitting density recovery to between 0.15 and 1.1 kg per cu km or about 2% of the mean density at periapsis during aerobraking. Accelerometer data were analyzed in near real time to provide estimates of density at periapsis, maximum density, density scale height, latitudinal gradient, longitudinal wave variations and location of the polar vortex. Summaries are given of the aerobraking phase of the mission, the accelerometer data analysis methods and operational procedures, some applications to determining thermospheric properties, and some remaining issues on interpretation of the data. Pre-flight estimates of natural variability based on Mars Global Surveyor accelerometer measurements proved reliable in the mid-latitudes, but overestimated the variability inside the polar vortex.

  12. Physical activity classification with dynamic discriminative methods.

    PubMed

    Ray, Evan L; Sasaki, Jeffer E; Freedson, Patty S; Staudenmayer, John

    2018-06-19

    A person's physical activity has important health implications, so it is important to be able to measure aspects of physical activity objectively. One approach to doing that is to use data from an accelerometer to classify physical activity according to activity type (e.g., lying down, sitting, standing, or walking) or intensity (e.g., sedentary, light, moderate, or vigorous). This can be formulated as a labeled classification problem, where the model relates a feature vector summarizing the accelerometer signal in a window of time to the activity type or intensity in that window. These data exhibit two key characteristics: (1) the activity classes in different time windows are not independent, and (2) the accelerometer features have moderately high dimension and follow complex distributions. Through a simulation study and applications to three datasets, we demonstrate that a model's classification performance is related to how it addresses these aspects of the data. Dynamic methods that account for temporal dependence achieve better performance than static methods that do not. Generative methods that explicitly model the distribution of the accelerometer signal features do not perform as well as methods that take a discriminative approach to establishing the relationship between the accelerometer signal and the activity class. Specifically, Conditional Random Fields consistently have better performance than commonly employed methods that ignore temporal dependence or attempt to model the accelerometer features. © 2018, The International Biometric Society.

  13. Experiment on interface separation detection of concrete-filled steel tubular arch bridge using accelerometer array

    NASA Astrophysics Data System (ADS)

    Pan, Shengshan; Zhao, Xuefeng; Zhao, Hailiang; Mao, Jian

    2015-04-01

    Based on the vibration testing principle, and taking the local vibration of steel tube at the interface separation area as the study object, a real-time monitoring and the damage detection method of the interface separation of concrete-filled steel tube by accelerometer array through quantitative transient self-excitation is proposed. The accelerometers are arranged on the steel tube area with or without void respectively, and the signals of accelerometers are collected at the same time and compared under different transient excitation points. The results show that compared with the signal of compact area, the peak value of accelerometer signal at void area increases and attenuation speed slows down obviously, and the spectrum peaks of the void area are much more and disordered and the amplitude increases obviously. whether the input point of transient excitation is on void area or not is irrelevant with qualitative identification results. So the qualitative identification of the interface separation of concrete-filled steel tube based on the signal of acceleration transducer is feasible and valid.

  14. Gyroscope-reduced inertial navigation system for flight vehicle motion estimation

    NASA Astrophysics Data System (ADS)

    Wang, Xin; Xiao, Lu

    2017-01-01

    In this paper, a novel configuration of strategically distributed accelerometer sensors with the aid of one gyro to infer a flight vehicle's angular motion is presented. The MEMS accelerometer and gyro sensors are integrated to form a gyroscope-reduced inertial measurement unit (GR-IMU). The motivation for gyro aided accelerometers array is to have direct measurements of angular rates, which is an improvement to the traditional gyroscope-free inertial system that employs only direct measurements of specific force. Some technical issues regarding error calibration in accelerometers and gyro in GR-IMU are put forward. The GR-IMU based inertial navigation system can be used to find a complete attitude solution for flight vehicle motion estimation. Results of numerical simulation are given to illustrate the effectiveness of the proposed configuration. The gyroscope-reduced inertial navigation system based on distributed accelerometer sensors can be developed into a cost effective solution for a fast reaction, MEMS based motion capture system. Future work will include the aid from external navigation references (e.g. GPS) to improve long time mission performance.

  15. Identification of capacitive MEMS accelerometer structure parameters for human body dynamics measurements.

    PubMed

    Benevicius, Vincas; Ostasevicius, Vytautas; Gaidys, Rimvydas

    2013-08-22

    Due to their small size, low weight, low cost and low energy consumption, MEMS accelerometers have achieved great commercial success in recent decades. The aim of this research work is to identify a MEMS accelerometer structure for human body dynamics measurements. Photogrammetry was used in order to measure possible maximum accelerations of human body parts and the bandwidth of the digital acceleration signal. As the primary structure the capacitive accelerometer configuration is chosen in such a way that sensing part measures on all three axes as it is 3D accelerometer and sensitivity on each axis is equal. Hill climbing optimization was used to find the structure parameters. Proof-mass displacements were simulated for all the acceleration range that was given by the optimization problem constraints. The final model was constructed in Comsol Multiphysics. Eigenfrequencies were calculated and model's response was found, when vibration stand displacement data was fed into the model as the base excitation law. Model output comparison with experimental data was conducted for all excitation frequencies used during the experiments.

  16. Analysis and amelioration about the cross-sensitivity of a high resolution MOEMS accelerometer based on diffraction grating

    NASA Astrophysics Data System (ADS)

    Lu, Qianbo; Bai, Jian; Wang, Kaiwei; Lou, Shuqi; Jiao, Xufen; Han, Dandan

    2016-10-01

    Cross-sensitivity is a crucial parameter since it detrimentally affect the performance of an accelerometer, especially for a high resolution accelerometer. In this paper, a suite of analytical and finite-elements-method (FEM) models for characterizing the mechanism and features of the cross-sensitivity of a single-axis MOEMS accelerometer composed of a diffraction grating and a micromachined mechanical sensing chip are presented, which have not been systematically investigated yet. The mechanism and phenomena of the cross-sensitivity of this type MOEMS accelerometer based on diffraction grating differ quite a lot from the traditional ones owing to the identical sensing principle. By analyzing the models, some ameliorations and the modified design are put forward to suppress the cross-sensitivity. The modified design, achieved by double sides etching on a specific double-substrate-layer silicon-on-insulator (SOI) wafer, is validated to have a far smaller cross-sensitivity compared with the design previously reported in the literature. Moreover, this design can suppress the cross-sensitivity dramatically without compromising the acceleration sensitivity and resolution.

  17. Microelectromechanical accelerometer with resonance-cancelling control circuit including an idle state

    DOEpatents

    Chu, Dahlon D.; Thelen, Jr., Donald C.; Campbell, David V.

    2001-01-01

    A digital feedback control circuit is disclosed for use in an accelerometer (e.g. a microelectromechanical accelerometer). The digital feedback control circuit, which periodically re-centers a proof mass in response to a sensed acceleration, is based on a sigma-delta (.SIGMA..DELTA.) configuration that includes a notch filter (e.g. a digital switched-capacitor filter) for rejecting signals due to mechanical resonances of the proof mass and further includes a comparator (e.g. a three-level comparator). The comparator generates one of three possible feedback states, with two of the feedback states acting to re-center the proof mass when that is needed, and with a third feedback state being an "idle" state which does not act to move the proof mass when no re-centering is needed. Additionally, the digital feedback control system includes an auto-zero trim capability for calibration of the accelerometer for accurate sensing of acceleration. The digital feedback control circuit can be fabricated using complementary metal-oxide semiconductor (CMOS) technology, bi-CMOS technology or bipolar technology and used in single- and dual-proof-mass accelerometers.

  18. In-flight estimation of center of gravity position using all-accelerometers.

    PubMed

    Al-Rawashdeh, Yazan Mohammad; Elshafei, Moustafa; Al-Malki, Mohammad Fahad

    2014-09-19

    Changing the position of the Center of Gravity (CoG) for an aerial vehicle is a challenging part in navigation, and control of such vehicles. In this paper, an all-accelerometers-based inertial measurement unit is presented, with a proposed method for on-line estimation of the position of the CoG. The accelerometers' readings are used to find and correct the vehicle's angular velocity and acceleration using an Extended Kalman Filter. Next, the accelerometers' readings along with the estimated angular velocity and acceleration are used in an identification scheme to estimate the position of the CoG and the vehicle's linear acceleration. The estimated position of the CoG and motion measurements can then be used to update the control rules to achieve better trim conditions for the air vehicle.

  19. Activity recognition in planetary navigation field tests using classification algorithms applied to accelerometer data.

    PubMed

    Song, Wen; Ade, Carl; Broxterman, Ryan; Barstow, Thomas; Nelson, Thomas; Warren, Steve

    2012-01-01

    Accelerometer data provide useful information about subject activity in many different application scenarios. For this study, single-accelerometer data were acquired from subjects participating in field tests that mimic tasks that astronauts might encounter in reduced gravity environments. The primary goal of this effort was to apply classification algorithms that could identify these tasks based on features present in their corresponding accelerometer data, where the end goal is to establish methods to unobtrusively gauge subject well-being based on sensors that reside in their local environment. In this initial analysis, six different activities that involve leg movement are classified. The k-Nearest Neighbors (kNN) algorithm was found to be the most effective, with an overall classification success rate of 90.8%.

  20. Implementation of an iPhone as a wireless accelerometer for quantifying gait characteristics.

    PubMed

    Lemoyne, Robert; Mastroianni, Timothy; Cozza, Michael; Coroian, Cristian; Grundfest, Warren

    2010-01-01

    The capacity to quantify and evaluate gait beyond the general confines of a clinical environment under effectively autonomous conditions may alleviate rampant strain on limited and highly specialized medical resources. An iPhone consists of a three dimensional accelerometer subsystem with highly robust and scalable software applications. With the synthesis of the integral iPhone features, an iPhone application, which constitutes a wireless accelerometer system for gait quantification and analysis, has been tested and evaluated in an autonomous environment. The acquired gait cycle data was transmitted wireless and through email for subsequent post-processing in a location remote to the location where the experiment was conducted. The iPhone application functioning as a wireless accelerometer for the acquisition of gait characteristics has demonstrated sufficient accuracy and consistency.

  1. Accelerometer Measurements in the Amusement Park.

    ERIC Educational Resources Information Center

    Reno, Charles; Speers, Robert R.

    1995-01-01

    Describes the use of the Texas Instruments' calculator-based laboratory (CBL) and Vernier accelerometer for measuring the vector sum of the gravitational field and the acceleration of amusement park rides. (JRH)

  2. Development of a Novel Translational Model of Vibration Injury to the Spine to Study Acute Injury in Vivo

    DTIC Science & Technology

    2012-10-01

    were collected at 500 Hz. In addition, for the ST1 tests only, positional data were collected using the Optotrak at 200 Hz. Acceleration was measured...the accelerometer in order to characterize the skin-accelerometer system. Optotrak position data were measured during ST1 using markers on the spinous...particular, we have analyzed transmissibility at T3 and L4, corresponding to where the accelerometers were placed, and using the Optotrak data at

  3. SPE-5 Ground-Motion Prediction at Far-Field Geophone and Accelerometer Array Sites and SPE-5 Moment and Corner-Frequency Prediction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xiaoning; Patton, Howard John; Chen, Ting

    2016-03-25

    This report offers predictions for the SPE-5 ground-motion and accelerometer array sites. These predictions pertain to the waveform and spectral amplitude at certain geophone sites using Denny&Johnson source model and a source model derived from SPE data; waveform, peak velocity and peak acceleration at accelerometer sites using the SPE source model and the finite-difference simulation with LLNL 3D velocity model; and the SPE-5 moment and corner frequency.

  4. Successful aquatic animal disease emergency programmes

    USGS Publications Warehouse

    Hastein, T.; Hill, B.J.; Winton, J.R.

    1999-01-01

    The third part provides a historical review of the build-up of infectious salmon anaemia (ISA) in Norway and the attempts to control the disease using legal measures in the absence of detailed knowledge of the aetiology, epizootiology, pathogenesis, etc. of the disease. The measures taken show that the spread of ISA can be controlled using restrictions on the movement of fish, disinfection procedures, etc. However, acceptance and understanding of the chosen strategy by the fish farmers is a pre-requisite to reach that goal. Finally, the paper summarises future needs for national and international legislation, including the development of standard approaches for control, the creation of appropriate infrastructures and a better understanding of the epidemiology of aquatic animal diseases.

  5. OntoMaton: a bioportal powered ontology widget for Google Spreadsheets.

    PubMed

    Maguire, Eamonn; González-Beltrán, Alejandra; Whetzel, Patricia L; Sansone, Susanna-Assunta; Rocca-Serra, Philippe

    2013-02-15

    Data collection in spreadsheets is ubiquitous, but current solutions lack support for collaborative semantic annotation that would promote shared and interdisciplinary annotation practices, supporting geographically distributed players. OntoMaton is an open source solution that brings ontology lookup and tagging capabilities into a cloud-based collaborative editing environment, harnessing Google Spreadsheets and the NCBO Web services. It is a general purpose, format-agnostic tool that may serve as a component of the ISA software suite. OntoMaton can also be used to assist the ontology development process. OntoMaton is freely available from Google widgets under the CPAL open source license; documentation and examples at: https://github.com/ISA-tools/OntoMaton.

  6. Controller design approach based on linear programming.

    PubMed

    Tanaka, Ryo; Shibasaki, Hiroki; Ogawa, Hiromitsu; Murakami, Takahiro; Ishida, Yoshihisa

    2013-11-01

    This study explains and demonstrates the design method for a control system with a load disturbance observer. Observer gains are determined by linear programming (LP) in terms of the Routh-Hurwitz stability criterion and the final-value theorem. In addition, the control model has a feedback structure, and feedback gains are determined to be the linear quadratic regulator. The simulation results confirmed that compared with the conventional method, the output estimated by our proposed method converges to a reference input faster when a load disturbance is added to a control system. In addition, we also confirmed the effectiveness of the proposed method by performing an experiment with a DC motor. © 2013 ISA. Published by ISA. All rights reserved.

  7. Autoantibodies Affect Brain Density Reduction in Nonneuropsychiatric Systemic Lupus Erythematosus Patients

    PubMed Central

    Xu, Jian; Cheng, Yuqi; Lai, Aiyun; Lv, Zhaoping; Yu, Hongjun; Luo, Chunrong; Shan, Baoci; Xu, Lin; Xu, Xiufeng

    2015-01-01

    This study explores the relationship between autoantibodies and brain density reduction in SLE patients without major neuropsychiatric manifestation (NPSLE). Ninety-five NPSLE patients without obvious cerebral deficits, as determined by conventional MRI, as well as 89 control subjects, underwent high-resolution structural MRI. Whole-brain density of grey matter (GMD) and white matter (WMD) were calculated for each individual, and correlations between the brain density, symptom severity, immunosuppressive agent (ISA), and autoantibody levels were assessed. The GMD and WMD of the SLE group decreased compared to controls. GMD was negatively associated with SLE activity. The WMD of patients who received ISA treatment were higher than that in the patients who did not. The WMD of patients with anticardiolipin (ACL) or anti-SSB/La antibodies was lower than in patients without these antibodies, while the GMD was lower in patients with anti-SM or anti-U1RNP antibodies. Thus, obvious brain atrophy can occur very early even before the development of significant symptoms and specific autoantibodies might contribute to the reduction of GMD or WMD in NPSLE patients. However, ISAs showed protective effects in minimizing GMD and WMD reduction. The presence of these specific autoantibodies might help identify early brain damage in NPSLE patients. PMID:26090505

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lien, Shu-Pei; Shih, Yi-Ping; Chen, Hsin-Wei

    Three peptides, D1 (amino acid residues 175-201), D2 (a.a. 434-467), and TM (a.a. 1128-1159), corresponding to the spike protein (S) of severe acute respiratory syndrome corona virus (SARS CoV) were synthesized and their immunological functions were investigated in three different animals models (mice, guinea pigs, and rabbits). The peptides mixture formulated either with Freund's adjuvant or synthetic adjuvant Montanide ISA-51/oligodeoxy nucleotide CpG (ISA/CpG) could elicit antisera in immunized animals which were capable of inhibiting SARS/HIV pseudovirus entry into HepG2 cells. The neutralizing epitopes were identified using peptides to block the neutralizing effect of guinea pig antisera. The major neutralizing epitopemore » was located on the D2 peptide, and the amino acid residue was fine mapped to 434-453. In BALB/c mice T-cell proliferation assay revealed that only D2 peptide contained T-cell epitope, the sequence of which corresponded to amino acid residue 434-448. The ISA/CpG formulation generated anti-D2 IgG titer comparable to those obtained from Freund's adjuvant formulation, but generated fewer antibodies against D1 or TM peptides. The highly immunogenic D2 peptide contains both neutralizing and Th cell epitopes. These results suggest that synthetic peptide D2 would be useful as a component of SARS vaccine candidates.« less

  9. The "Case of Two Compounds with Similar Configuration but Nearly Mirror Image CD Spectra" Refuted. Reassignment of the Absolute Configuration of N-Formyl-3',4'-dihydrospiro[indan-1,2'(1'H)-pyridine].

    PubMed

    Padula, Daniele; Di Bari, Lorenzo; Pescitelli, Gennaro

    2016-09-02

    In 1997, Sandström and co-workers reported the case of two chiral spiro compounds with very similar skeletons but showing almost mirror-image electronic circular dichroism (ECD) spectra for the corresponding absolute configuration. The paper has been often cited as a proof and good educational example of the pronounced sensitivity of ECD toward molecular conformation, and a clear warning against the use of ECD spectral correlations to assign absolute configurations. Although both concepts remain valid, they are not exemplified by the quoted paper. We demonstrate that the original configurational assignment of one compound was wrong and revise it by using TDDFT calculations. The main reason for the observed failure is the use of the matrix method, a popular approach to predict ECD spectra of compounds which can be treated with an independent system approximation (ISA), including proteins. Using a modern version of the matrix method, we demonstrate that the ISA is not valid for the title compound. Even in the absence of apparent conjugation between the component chromophores, the validity of the ISA should never be taken for granted and the effective extent of orbital overlap should always be verified.

  10. Addressing Theory and Performance Enhancements for the Independent Sustain and Address AC Plasma Display

    NASA Astrophysics Data System (ADS)

    Warren, Kevin Wilson

    The Independent Sustain and Address (ISA) AC plasma panel is a flat, flicker-free, gas discharge type of display device. This display technology promises to reduce both the cost of manufacturing and operation of AC plasma displays. The ISA technology uses a vastly different mechanism to change the state of the display pixels than the standard AC plasma technology. This addressing mechanism is an exploitation of some of the natural characteristics associated with the plasma that can form during strong gas discharges. This thesis presents detailed data from experiments that were designed to evaluate and test the effectiveness of this mechanism. Through these experiments, the theory that the addressing methodology is based upon is developed and evaluated. These experiments show that the address margin windows for this technology are very large, minimally two to three times larger than the address margins for the standard XY AC plasma addressing techniques. New capabilities are also described, such as global brightness control for the ISA technology and a technique for increasing the addressing rate. These advances were designed into working prototypes and transferred to industry where there are currently commercial products available based upon these advances. A technique for implementing gray scale using some of these advances is also proposed.

  11. Concept Mapping of PMTCT Implementation Challenges and Solutions Across 6 sub-Saharan African Countries in the NIH-PEPFAR PMTCT Implementation Science Alliance.

    PubMed

    Aarons, Gregory A; Sommerfeld, David H; Chi, Benjamin H; Ezeanolue, Echezona E; Sturke, Rachel; Guay, Laura; Siberry, George K

    2016-08-01

    Although tremendous gains have been made to reduce mother-to-child HIV transmission (MTCT) globally, evidence-based practice implementation remains inconsistent in sub-Saharan Africa. We sought to identify the key domains for effective prevention of MTCT (PMTCT) implementation, using a participatory mixed-methods approach. Participants were members of the NIH-PEPFAR PMTCT Implementation Science Alliance (ISA), a platform of researchers, public-health practitioners, policymakers, and donors supported through NIH/PEPFAR. We used concept mapping to identify priority areas for PMTCT implementation science. Participants responded to the focus question: "In your experience, what factors have facilitated or hindered implementation of PMTCT interventions?" Responses were consolidated into discrete statements, grouped together based on similarity, and rated for importance, changeability, and extent to which ISA participation enhanced the capacity to influence/change the factor. Using multidimensional scaling and cluster analysis, we identified 12 key domains of PMTCT implementation. Two domains (Governmental Commitment and Data Measurement & Collection) were consistently ranked at or near the top for overall importance, perceived changeability, and enhanced ability to address through ISA participation. Through a stakeholder-based, participatory approach, we identified key domains for that should be considered for future PMTCT implementation research in sub-Saharan Africa.

  12. Behavioural responses of spinner dolphins to human interactions

    PubMed Central

    Cesario, Amina; Costa, Marina; Harraway, John; Notarbartolo di Sciara, Giuseppe; Slooten, Elisabeth

    2018-01-01

    There is increasing evidence that whale and dolphin watching activities have detrimental effects on targeted cetacean populations. In Egypt, spinner dolphins regularly occur in the resting areas of Samadai, Satayah and Qubbat'Isa reefs. In-water human interactions with dolphins are regulated with a time-area closure system at Samadai, unregulated at Satayah and non-existent at Qubbat'Isa. This provided an ideal experimental setting to advance our understanding of the effects of tourism on a species highly sensitive to disturbances. Our study confirmed that the intensity and duration of interactions, and therefore, dolphin exposure to tourism, differed among the study sites. Compared with the Qubbat'Isa control site, behavioural reactions to boats and swimmers at the two tourism sites suggested that dolphin rest was disrupted, especially around the middle of the day and especially at Satayah, where dolphin tourism is unregulated. Our results indicate also that the dolphin protection measures at Samadai reduce the level of disturbance. We recommend that similar measures be implemented at other dolphin tourism locations, and that no new operations be initiated until the long-term impacts on dolphin populations are better understood. Our experience emphasizes the need to adopt precautionary approaches in research and management of whale and dolphin watching. PMID:29765660

  13. DPP10 splice variants are localized in distinct neuronal populations and act to differentially regulate the inactivation properties of Kv4-based ion channels.

    PubMed

    Jerng, Henry H; Lauver, Aaron D; Pfaffinger, Paul J

    2007-08-01

    Dipeptidyl peptidase-like proteins (DPLs) and Kv-channel-interacting proteins (KChIPs) join Kv4 pore-forming subunits to form multi-protein complexes that underlie subthreshold A-type currents (I(SA)) in neuronal somatodendritic compartments. Here, we characterize the functional effects and brain distributions of N-terminal variants belonging to the DPL dipeptidyl peptidase 10 (DPP10). In the Kv4.2+KChIP3+DPP10 channel complex, all DPP10 variants accelerate channel gating kinetics; however, the splice variant DPP10a produces uniquely fast inactivation kinetics that accelerates with increasing depolarization. This DPP10a-specific inactivation dominates in co-expression studies with KChIP4a and other DPP10 isoforms. Real-time qRT-PCR and in situ hybridization analyses reveal differential expression of DPP10 variants in rat brain. DPP10a transcripts are prominently expressed in the cortex, whereas DPP10c and DPP10d mRNAs exhibit more diffuse distributions. Our results suggest that DPP10a underlies rapid inactivation of cortical I(SA), and the regulation of isoform expression may contribute to the variable inactivation properties of I(SA) across different brain regions.

  14. A Miniature High-Sensitivity Braodband Accelerometer Based on Electron Tunneling Transducers

    NASA Technical Reports Server (NTRS)

    Rockstad, H.; Kenny, T.; Reynolds, J.; Kaiser, W.; Gabrielson, T.

    1993-01-01

    This paper describes the successful fabrication and demonstration of a new dual-element micromachined silicon tunnel accelerometer that extends the operational bandwidth beyond the resonant frequency of the proof mass.

  15. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1996-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto. Art accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  16. In-Flight Estimation of Center of Gravity Position Using All-Accelerometers

    PubMed Central

    Al-Rawashdeh, Yazan Mohammad; Elshafei, Moustafa; Al-Malki, Mohammad Fahad

    2014-01-01

    Changing the position of the Center of Gravity (CoG) for an aerial vehicle is a challenging part in navigation, and control of such vehicles. In this paper, an all-accelerometers-based inertial measurement unit is presented, with a proposed method for on-line estimation of the position of the CoG. The accelerometers' readings are used to find and correct the vehicle's angular velocity and acceleration using an Extended Kalman Filter. Next, the accelerometers' readings along with the estimated angular velocity and acceleration are used in an identification scheme to estimate the position of the CoG and the vehicle's linear acceleration. The estimated position of the CoG and motion measurements can then be used to update the control rules to achieve better trim conditions for the air vehicle. PMID:25244585

  17. Accelerometer Method and Apparatus for Integral Display and Control Functions

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor)

    1998-01-01

    Method and apparatus for detecting mechanical vibrations and outputting a signal in response thereto is discussed. An accelerometer package having integral display and control functions is suitable for mounting upon the machinery to be monitored. Display circuitry provides signals to a bar graph display which may be used to monitor machine conditions over a period of time. Control switches may be set which correspond to elements in the bar graph to provide an alert if vibration signals increase in amplitude over a selected trip point. The circuitry is shock mounted within the accelerometer housing. The method provides for outputting a broadband analog accelerometer signal, integrating this signal to produce a velocity signal, integrating and calibrating the velocity signal before application to a display driver, and selecting a trip point at which a digitally compatible output signal is generated.

  18. Physical activity correlates with neurological impairment and disability in multiple sclerosis.

    PubMed

    Motl, Robert W; Snook, Erin M; Wynn, Daniel R; Vollmer, Timothy

    2008-06-01

    This study examined the correlation of physical activity with neurological impairment and disability in persons with multiple sclerosis (MS). Eighty individuals with MS wore an accelerometer for 7 days and completed the Symptom Inventory (SI), Performance Scales (PS), and Expanded Disability Status Scale. There were large negative correlations between the accelerometer and SI (r = -0.56; rho = -0.58) and Expanded Disability Status Scale (r = -0.60; rho = -0.69) and a moderate negative correlation between the accelerometer and PS (r = -0.39; rho = -0.48) indicating that physical activity was associated with reduced neurological impairment and disability. Such findings provide a preliminary basis for using an accelerometer and the SI and PS as outcome measures in large-scale prospective and experimental examinations of the effect of physical activity behavior on disability and dependence in MS.

  19. Structural design of high-performance capacitive accelerometers using parametric optimization with uncertainties

    NASA Astrophysics Data System (ADS)

    Teves, André da Costa; Lima, Cícero Ribeiro de; Passaro, Angelo; Silva, Emílio Carlos Nelli

    2017-03-01

    Electrostatic or capacitive accelerometers are among the highest volume microelectromechanical systems (MEMS) products nowadays. The design of such devices is a complex task, since they depend on many performance requirements, which are often conflicting. Therefore, optimization techniques are often used in the design stage of these MEMS devices. Because of problems with reliability, the technology of MEMS is not yet well established. Thus, in this work, size optimization is combined with the reliability-based design optimization (RBDO) method to improve the performance of accelerometers. To account for uncertainties in the dimensions and material properties of these devices, the first order reliability method is applied to calculate the probabilities involved in the RBDO formulation. Practical examples of bulk-type capacitive accelerometer designs are presented and discussed to evaluate the potential of the implemented RBDO solver.

  20. Terrestrial Applications of a Nano-g Accelerometer

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T.

    1996-01-01

    The ultra-sensitive accelerometer, developed for NASA to monitor the microgravity environments of Space Shuttle, five orbiters and Space Station, needed to measure accelerations up to 10 mg with an absolute accuracy of 10 nano-g (10(exp -8)g) for at least two orbits (10(exp 4) seconds) to resolve accelerations associated with orbital drag. Also, the accelerometers needed to have less than 10(exp -9) F.S. off-axis sensitivity; to be thermally and magnetically inert; to be immune to quiescent shock, and to have an in-situ calibration capability. Multi-axis compact seismometers, designs that have twelve decades of dynamic range will be described. Density profilometers, precision gradiometers, gyros and vibration isolation designs and applications will be discussed. Finally, examples of transformations of the accelerometer into sensitive anemometers and imaging spectrometers will be presented.

Top