Sample records for stability-indicating rp-lc method

  1. Determination of aliskiren in tablet dosage forms by a validated stability-indicating RP-LC method.

    PubMed

    Wrasse-Sangoi, M; Sangoi, M S; Oliveira, P R; Secretti, L T; Rolim, C M B

    2011-02-01

    A reversed-phase liquid chromatography (RP-LC) method is validated for the determination of aliskiren in tablet dosage form. The LC method is carried out on a Waters XBridge C(18) column (150 × 4.6 mm i.d.), maintained at 25°C. The mobile phase consisted of acetonitrile:water (95:5, v/v)/phosphoric acid (25 mM, pH 3.0) (40:60, v/v), run at a flow rate of 1.0 mL/min, with photodiode array detector set at 229 nm. The chromatographic separation is obtained with aliskiren retention time of 3.68 min, and it is linear in the range of 10-300 μg/mL (r = 0.9999). The limits of detection and quantitation are 2.38 and 7.93 μg/mL, respectively. The specificity and stability-indicating capability of the method are proven through degradation studies, which also showed that there is no interference of the formulation excipients, showing that peak is free from any coeluting peak. The method showed adequate precision, with a relative standard deviation (RSD) values lower than 0.92%. Good values of accuracy were also obtained, with a mean value of 99.55%. Experimental design is used during validation to calculate method robustness. The proposed method is applied for the analysis of the tablet dosage forms, contributing to improve the quality control and to assure the therapeutic efficacy.

  2. Stability-indicating RP-HPLC method for the simultaneous determination of escitalopram oxalate and clonazepam.

    PubMed

    Kakde, Rajendra B; Satone, Dinesh D; Gadapayale, Kamalesh K; Kakde, Megha G

    2013-07-01

    The objective of the current study was to develop a validated, specific stability-indicating reversed-phase liquid chromatographic (LC) method for the quantitative determination of escitalopram oxalate and clonazepam and their related substances in bulk drugs and pharmaceutical dosage forms in the presence of degradation products. Forced degradation studies were performed on the pure drugs of escitalopram oxalate and clonazepam, as per the stress conditions prescribed by the International Conference on Harmonization (ICH) using acid, base, oxidation, thermal stress and photolytic degradation to show the stability-indicating power of the method. Significant degradation was observed during acid and alkaline hydrolysis and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies. Good resolution between the peaks corresponded to the active pharmaceutical ingredients, escitalopram oxalate and clonazepam, and degradation products from the analyte were achieved on an ODS Hypersil C18 column (250 × 4.6 mm) using a mobile phase consisting of a mixture of acetonitrile-50 mM phosphate buffer + 10 mM triethylamine (70:30, v/v). The detection was conducted at 268 nm. The limit of detection and the limit of quantitation for escitalopram oxalate and clonazepam were established. The stress test solutions were assayed against the qualified working standards of escitalopram oxalate and clonazepam, which indicated that the developed LC method was stability-indicating. Validation of the developed LC method was conducted as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of escitalopram oxalate and clonazepam.

  3. Identification and characterization of stress degradants of lacosamide by LC-MS and ESI-Q-TOF-MS/MS: development and validation of a stability indicating RP-HPLC method.

    PubMed

    Ramisetti, Nageswara Rao; Kuntamukkala, Ramakrishna; Lakshetti, Sridhar; Sripadi, Prabhakar

    2014-07-01

    The current study dealt with the degradation behavior of lacosamide (LAC) under ICH prescribed stress conditions. LAC was found to be labile under acid and base hydrolytic stress conditions, while it was stable to neutral hydrolytic, oxidative, photolytic and thermal stress. In total, seven degradation products (DPs) were formed, which were separated on a C18 column using a stability-indicating method. LC-MS analyses indicated that one of the DPs had the same molecular mass as that of the drug. Structural characterization of DPs was carried out using ESI-Q-TOF-MS/MS technique. The degradation pathways and mechanisms of degradation of the drug were delineated by carrying out the degradation in different co-solvents viz. methanol, deuterated methanol, ethanol, 1-propanol and acetonitrile. The developed LC method was validated for the determination of related substances and assay of LAC as per ICH guidelines. This study demonstrates a comprehensive approach of LAC degradation studies during its development phase. Copyright © 2014. Published by Elsevier B.V.

  4. Development and Validation of RP-LC Method for the Determination of Cinnarizine/Piracetam and Cinnarizine/Heptaminol Acefyllinate in Presence of Cinnarizine Reported Degradation Products

    PubMed Central

    EL-Houssini, Ola M.; Zawilla, Nagwan H.; Mohammad, Mohammad A.

    2013-01-01

    Specific stability indicating reverse-phase liquid chromatography (RP-LC) assay method (SIAM) was developed for the determination of cinnarizine (Cinn)/piracetam (Pira) and cinnarizine (Cinn)/heptaminol acefyllinate (Hept) in the presence of the reported degradation products of Cinn. A C18 column and gradient mobile phase was applied for good resolution of all peaks. The detection was achieved at 210 nm and 254 nm for Cinn/Pira and Cinn/Hept, respectively. The responses were linear over concentration ranges of 20–200, 20–1000 and 25–1000 μgmL−1 for Cinn, Pira, and Hept respectively. The proposed method was validated for linearity, accuracy, repeatability, intermediate precision, and robustness via statistical analysis of the data. The method was shown to be precise, accurate, reproducible, sensitive, and selective for the analysis of Cinn/Pira and Cinn/Hept in laboratory prepared mixtures and in pharmaceutical formulations. PMID:24137049

  5. A validated stability-indicating RP-HPLC method for levofloxacin in the presence of degradation products, its process related impurities and identification of oxidative degradant.

    PubMed

    Lalitha Devi, M; Chandrasekhar, K B

    2009-12-05

    The objective of current study was to develop a validated specific stability indicating reversed-phase liquid chromatographic method for the quantitative determination of levofloxacin as well as its related substances determination in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its process related impurities. Forced degradation studies were performed on bulk sample of levofloxacin as per ICH prescribed stress conditions using acid, base, oxidative, water hydrolysis, thermal stress and photolytic degradation to show the stability indicating power of the method. Significant degradation was observed during oxidative stress and the degradation product formed was identified by LCMS/MS, slight degradation in acidic stress and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from forced degradation studies and the impurity spiked solution. Good resolution between the peaks corresponds to process related impurities and degradation products from the analyte were achieved on ACE C18 column using the mobile phase consists a mixture of 0.5% (v/v) triethyl amine in sodium dihydrogen orthophosphate dihydrate (25 mM; pH 6.0) and methanol using a simple linear gradient. The detection was carried out at 294 nm. The limit of detection and the limit of quantitation for the levofloxacin and its process related impurities were established. The stressed test solutions were assayed against the qualified working standard of levofloxacin and the mass balance in each case was in between 99.4 and 99.8% indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per ICH requirements. The developed LC method was found to be suitable to check the quality of bulk samples of levofloxacin at the time of batch release and also during its stability studies (long term and accelerated stability).

  6. A validated specific stability-indicating RP-HPLC assay method for Ambrisentan and its related substances.

    PubMed

    Narayana, M B V; Chandrasekhar, K B; Rao, B M

    2014-09-01

    A validated specific stability-indicating reverse-phase liquid chromatographic method was developed for the quantitative determination of Ambrisentan as well as its related substances in bulk samples, pharmaceutical dosage forms in the presence of degradation products and its related impurities. Forced degradation studies were performed on bulk samples of Ambrisentan as per the ICH-prescribed stress conditions using acid, base, oxidative, thermal stress and photolytic degradation to show the stability-indicating power of the LC method. Significant degradation in acidic, basic stress conditions was observed and no degradation was observed in other stress conditions. The chromatographic method was optimized using the samples generated from the forced degradation studies and the impurity-spiked solution. Good resolution between the peaks corresponds to Ambrisentan-related impurities and degradation products from the analyte were achieved on a SunFire C18 column using a mobile phase consisting of a mixture of potassium dihydrogen orthophosphate at a pH adjusted to 2.5 with ortho-phosphoric acid in water and a mixture of acetonitrile:methanol using a simple linear gradient. The detection was carried out at 225 nm. The limit of detection and the limit of quantification for the Ambrisentan and its related impurities were established. The stressed test solutions were assayed against the qualified working standard of Ambrisentan and the mass balance in each case was between 98.9 and 100.3%, indicating that the developed LC method was stability indicating. Validation of the developed LC method was carried out as per the ICH requirements. The developed method was found to be suitable to check the quality of bulk samples of Ambrisentan at the time of batch release and also during its storage (long-term and accelerated stability). © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms

    PubMed Central

    Reddy, Sunil Pingili; Babu, K. Sudhakar; Kumar, Navneet; Sekhar, Y. V. V. Sasi

    2011-01-01

    Aim and background: A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. Materials and methods: The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Results: Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. Conclusion: The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781462

  8. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms.

    PubMed

    Reddy, Sunil Pingili; Babu, K Sudhakar; Kumar, Navneet; Sekhar, Y V V Sasi

    2011-10-01

    A stability-indicating gradient reverse phase liquid chromatographic (RP-LC) method was developed for the quantitative determination of related substances of guaifenesin in pharmaceutical formulations. The baseline separation for guaifenesin and all impurities was achieved by utilizing a Water Symmetry C18 (150 mm × 4.6 mm) 5 μm column particle size and a gradient elution method. The mobile phase A contains a mixture of 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 90:10 v/v, while the mobile phase B contains 0.02 M KH2PO4 (pH 3.2) and methanol in the ratio of 10:90 v/v, respectively. The flow rate of the mobile phase was 0.8 ml/min with a column temperature of 25°C and detection wavelength at 273 nm. Guaifenesin was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, and photolytic degradation. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness.

  9. Development and validation of a stability-indicating size-indicating size-exclusion LC method for the determination of rhIFN-alpha2a in pharmaceutical formulations.

    PubMed

    Zimmermann, Estevan Sonego; da Silva, Lucélia Magalhães; Calegari, Guilherme Zanini; Stamm, Fernanda Pavani; Souto, Ricardo Bizogne; Dalmora, Sérgio Luiz

    2013-01-01

    A size-exclusion LC method was validated for the determination of interferon-a2a (rhlFN-alpha2a) in pharmaceutical formulations without interference from human serum albumin. Chromatographic separation was performed on a BioSep-SEC-S 2000 column (300 x 7.8 mm id). The mobile phase consisted of 0.001 M monobasic potassium phosphate, 0.008 M sodium phosphate dibasic; 0.2 M sodium chloride buffer, pH 7.4, run at a gradient flow rate and using photodiode array detection at 214 nm, was used. Chromatographic separation was achieved with a retention time of 17.2 min, and the analysis was linear over the concentration range of 1.98 to 198 microg/mL (r2 = 0.9996). The accuracy was 101.39%, with bias lower than 1.67%. The LOD and LOQ were 0.87 and 1.98 microg/mL, respectively. Moreover, method validation demonstrated acceptable results for precision and robustness. The method was applied to the assessment of rhlFN-alpha2a and related proteins in biopharmaceutical dosage forms, and the content/potencies were correlated to those given by a validated RP-LC method and an in vitro bioassay. It was concluded that use of the methods in conjunction allows a great improvement in monitoring stability and QC, thereby ensuring the therapeutic efficacy of the biotechnology-derived medicine.

  10. Development of RP-HPLC, Stability Indicating Method for Degradation Products of Linagliptin in Presence of Metformin HCl by Applying 2 Level Factorial Design; and Identification of Impurity-VII, VIII and IX and Synthesis of Impurity-VII.

    PubMed

    Jadhav, Sushant B; Reddy, P Sunil; Narayanan, Kalyanaraman L; Bhosale, Popatrao N

    2017-06-27

    The novel reverse phase-high performance liquid chromatography (RP-HPLC), stability indicating method was developed for determination of linagliptin (LGP) and its related substances in linagliptin and metformin HCl (MET HCl) tablets by implementing design of experiment to understand the critical method parameters and their relation with critical method attributes; to ensure robustness of the method. The separation of nine specified impurities was achieved with a Zorbax SB-Aq 250 × 4.6 mm, 5 µm column, using gradient elution and a detector wavelength of 225 nm, and validated in accordance with International Conference on Harmonization (ICH) guidelines and found to be accurate, precise, reproducible, robust, and specific . The drug was found to be degrading extensively in heat, humidity, basic, and oxidation conditions and was forming degradation products during stability studies. After slight modification in the buffer and the column, the same method was used for liquid chromatography-mass spectrometry (LC-MS) and ultra-performance liquid chromatography -time-of-flight/mass spectrometry UPLC-TOF/MS analysis, to identify m/z and fragmentation of maximum unspecified degradation products i.e., Impurity-VII ( 7 ), Impurity-VIII ( 8 ), and Impurity-IX ( 9 ) formed during stability studies. Based on the results, a degradation pathway for the drug has been proposed and synthesis of Impurity-VII ( 7 ) is also discussed to ensure an in-depth understanding of LGP and its related degradation products and optimum performance during the lifetime of the product.

  11. Development of RP UPLC-TOF/MS, stability indicating method for omeprazole and its related substances by applying two level factorial design; and identification and synthesis of non-pharmacopoeial impurities.

    PubMed

    Jadhav, Sushant Bhimrao; Kumar, C Kiran; Bandichhor, Rakeshwar; Bhosale, P N

    2016-01-25

    A new UPLC-TOF/MS compatible, reverse phase-stability indicating method was developed for determination of Omeprazole (OMP) and its related substances in pharmaceutical dosage forms by implementing Design of Experiment (DoE) i.e. two level full factorial Design (2(3)+3 center points=11 experiments) to understand the Critical Method Parameters (CMP) and its relation with Critical Method Attribute (CMA); to ensure robustness of the method. The separation of eleven specified impurities including conversion product of OMP related compound F (13) and G (14) i.e. Impurity-I (1), OMP related compound-I (11) and OMP 4-chloro analog (12) was achieved in a single method on Acquity BEH shield RP18 100 × 2.1 mm, 1.7 μm column, with inlet filter (0.2 μm) using gradient elution and detector wavelength at 305 nm and validated in accordance with ICH guidelines and found to be accurate, precise, reproducible, robust and specific. The drug was found to degrade extensively in heat, humidity and acidic conditions and forms unknown degradation products during stability studies. The same method was used for LC-MS analysis to identify m/z and fragmentation of maximum unknown impurities (Non-Pharmacopoeial) i.e. Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9) formed during stability studies. Based on the results, degradation pathway for the drug has been proposed and synthesis of identified impurities i.e. impurities (Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9)) are discussed in detail to ensure in-depth understanding of OMP and its related impurities and optimum performance during lifetime of the product. Copyright © 2015. Published by Elsevier B.V.

  12. Offline pentafluorophenyl (PFP)-RP prefractionation as an alternative to high-pH RP for comprehensive LC-MS/MS proteomics and phosphoproteomics.

    PubMed

    Grassetti, Andrew V; Hards, Rufus; Gerber, Scott A

    2017-07-01

    Technological advances in liquid chromatography and tandem mass spectrometry (LC-MS/MS) have enabled comprehensive analyses of proteins and their post-translational modifications from cell culture and tissue samples. However, sample complexity necessitates offline prefractionation via a chromatographic method that is orthogonal to online reversed-phase high-performance liquid chromatography (RP-HPLC). This additional fractionation step improves target identification rates by reducing the complexity of the sample as it is introduced to the instrument. A commonly employed offline prefractionation method is high pH reversed-phase (Hi-pH RP) chromatography. Though highly orthogonal to online RP-HPLC, Hi-pH RP relies on buffers that interfere with electrospray ionization. Thus, samples that are prefractionated using Hi-pH RP are typically desalted prior to LC-MS/MS. In the present work, we evaluate an alternative offline prefractionation method, pentafluorophenyl (PFP)-based reversed-phase chromatography. Importantly, PFP prefractionation results in samples that are dried prior to analysis by LC-MS/MS. This reduction in sample handling relative to Hi-pH RP results in time savings and could facilitate higher target identification rates. Here, we have compared the performances of PFP and Hi-pH RP in offline prefractionation of peptides and phosphopeptides that have been isolated from human cervical carcinoma (HeLa) cells. Given the prevalence of isobaric mass tags for peptide quantification, we evaluated PFP chromatography of peptides labeled with tandem mass tags. Our results suggest that PFP is a viable alternative to Hi-pH RP for both peptide and phosphopeptide offline prefractionation.

  13. WE-AB-207B-02: A Bayesian Network Approach for Joint Prediction of Tumor Control and Radiation Pneumonitis (RP) in Non-Small-Cell Lung Cancer (NSCLC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Y; McShan, D; Matuszak, M

    Purpose: NSCLC radiotherapy treatment is a trade-off between controlling the tumor while limiting radiation-induced toxicities. Here we identify hierarchical biophysical relationships that could simultaneously influence both local control (LC) and RP by using an integrated Bayesian Networks (BN) approach. Methods: We studied 79 NSCLC patients treated on prospective protocol with 56 cases of LC and 21 events of RP. Beyond dosimetric information, each patient had 193 features including 12 clinical factors, 60 circulating blood cytokines before and during radiotherapy, 62 microRNAs, and 59 single-nucleotide polymorphisms (SNPs). The most relevant biophysical predictors for both LC and RP were identified using amore » Markov blanket local discovery algorithm and the corresponding BN was constructed using a score-learning algorithm. The area under the free-response receiver operating characteristics (AU-FROC) was used for performance evaluation. Cross-validation was employed to guard against overfitting pitfalls. Results: A BN revealing the biophysical interrelationships jointly in terms of LC and RP was developed and evaluated. The integrated BN included two SNPs, one microRNA, one clinical factor, three pre-treatment cytokines, relative changes of two cytokines between pre and during-treatment, and gEUDs of the GTV (a=-20) and lung (a=1). On cross-validation, the AUC prediction of independent LC was 0.85 (95% CI: 0.75–0.95) and RP was 0.83 (0.73–0.92). The AU-FROC of the integrated BN to predict both LC/RP was 0.81 (0.71–0.90) based on 2000 stratified bootstrap, indicating minimal loss in joint prediction power. Conclusions: We developed a new approach for multiple outcome utility application in radiotherapy based on integrated BN techniques. The BN developed from large-scale retrospective data is able to simultaneously predict LC and RP in NSCLC treatments based on individual patient characteristics. The joint prediction is only slightly compromised compared to independent predictions. Our approach shows promise for use in clinical decision support system for personalized radiotherapy subject to multiple endpoints. These studies were supported by a grant from the NCI/NIH P01-CA59827.« less

  14. Analysis of pharmaceutical impurities using multi-heartcutting 2D LC coupled with UV-charged aerosol MS detection.

    PubMed

    Zhang, Kelly; Li, Yi; Tsang, Midco; Chetwyn, Nik P

    2013-09-01

    To overcome challenges in HPLC impurity analysis of pharmaceuticals, we developed an automated online multi-heartcutting 2D HPLC system with hyphenated UV-charged aerosol MS detection. The first dimension has a primary column and the second dimension has six orthogonal columns to enhance flexibility and selectivity. The two dimensions were interfaced by a pair of switching valves equipped with six trapping loops that allow multi-heartcutting of peaks of interest in the first dimension and also allow "peak parking." The hyphenated UV-charged aerosol MS detection provides comprehensive detection for compounds with and without UV chromophores, organics, and inorganics. It also provides structural information for impurity identification. A hidden degradation product that co-eluted with the drug main peak was revealed by RP × RP separation and thus enabled the stability-indicating method development. A poorly retained polar component with no UV chromophores was analyzed by RP × hydrophilic interaction liquid chromatography separation with charged aerosol detection. Furthermore, using this system, the structures of low-level impurities separated by a method using nonvolatile phosphate buffer were identified and tracked by MS in the second dimension. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Stability-Indicating Liquid Chromatographic Methods with Photodiode Array Detection and Light Scattering Detection for Simultaneous Determination of Candesartan and Hydrochlorothiazide.

    PubMed

    de Diego, Marta; Godoy, Ricardo; Mennickent, Sigrid; Vergara, Carola; Miranda, Daniel; Navarro, Pía

    2018-02-01

    Development, validation and comparison of two stability-indicating LC methods, one with photodiode array detector (DAD) and the other with evaporative light scattering detector (ELSD), were performed for simultaneous determination of candesartan cilexetil (CANC) and hydrochlorothiazide (HCTZ), in pharmaceutical samples. A RP-18 column (125 mm × 4 mm, 5 μm) was used for separation of CANC, HCTZ and its major degradation products, using acetonitrile and phosphate buffer (pH 6.0) for DAD method and acetonitrile and water with acetic acid and triethylamine (pH 4.1) for ELSD method, as mobile phase in a gradient mode. The response with ELSD was fitted to a power function and the DAD response by a linear model over a range of 32-160 μg/mL for CANC and 25-125 μg/mL for HCTZ. The precision and accuracy of the methods were similar, with RSD below 3.0% and recovery between 98.1% and 103.9%. The drugs were subjected to stress conditions of hydrolysis, oxidation, photolysis, humidity and temperature. The degradation products were satisfactory separated from the main peaks and from each other. Both drugs mainly degrade by hydrolysis, showing the formation of one degradation product for HCTZ and two for CANC; its identification was conducted by LC/MS/MS. The methods were successfully applied to the analysis of CANC and HCTZ in combined commercial tablets. The performance of DAD and ELSD methods are comparable, therefore both methods are suitable for stability study and determination of CANC and HCTZ in pharmaceutical samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Development and validation of an LC-UV method for the quantification and purity determination of the novel anticancer agent C1311 and its pharmaceutical dosage form.

    PubMed

    den Brok, Monique W J; Nuijen, Bastiaan; Hillebrand, Michel J X; Grieshaber, Charles K; Harvey, Michael D; Beijnen, Jos H

    2005-09-01

    C1311 (5-[[2-(diethylamino)ethyl]amino]-8-hydroxyimidazo [4,5,1-de]-acridin-6-one-dihydrochloride trihydrate) is the lead compound from the group of imidazoacridinones, a novel group of rationally designed anticancer agents. The pharmaceutical development of C1311 necessitated the availability of an assay for the quantification and purity determination of C1311 active pharmaceutical ingredient (API) and its pharmaceutical dosage form. A reversed-phase liquid chromatographic method (RP-LC) with ultraviolet (UV) detection was developed, consisting of separation on a C18 column with phosphate buffer (60 mM; pH 3 with 1 M citric acid)-acetonitrile-triethylamine (83:17:0.05, v/v/v) as the mobile phase and UV-detection at 280 nm. The method was found to be linear over a concentration range of 2.50-100 microg/mL, precise and accurate. Accelerated stress testing showed degradation products, which were well separated from the parent compound, confirming its stability-indicating capacity. Moreover, the use of LC-MS and on-line photo diode array detection enabled us to propose structures for four degradation products. Two of these products were also found as impurities in the API and more abundantly in an impure lot of API.

  17. Stationary-phase optimized selectivity liquid chromatography: development of a linear gradient prediction algorithm.

    PubMed

    De Beer, Maarten; Lynen, Fréderic; Chen, Kai; Ferguson, Paul; Hanna-Brown, Melissa; Sandra, Pat

    2010-03-01

    Stationary-phase optimized selectivity liquid chromatography (SOS-LC) is a tool in reversed-phase LC (RP-LC) to optimize the selectivity for a given separation by combining stationary phases in a multisegment column. The presently (commercially) available SOS-LC optimization procedure and algorithm are only applicable to isocratic analyses. Step gradient SOS-LC has been developed, but this is still not very elegant for the analysis of complex mixtures composed of components covering a broad hydrophobicity range. A linear gradient prediction algorithm has been developed allowing one to apply SOS-LC as a generic RP-LC optimization method. The algorithm allows operation in isocratic, stepwise, and linear gradient run modes. The features of SOS-LC in the linear gradient mode are demonstrated by means of a mixture of 13 steroids, whereby baseline separation is predicted and experimentally demonstrated.

  18. Stability-indicating validation of acitretin and isoacitretin in human plasma by LC-ESI-MS/MS bioanalytical method and its application to pharmacokinetic analysis.

    PubMed

    Kumar, Ajay; Monif, Tausif; Khuroo, Arshad; Sasmal, Dinakar; Goswami, Dipanjan; Lahkar, Vijay Kumar

    2011-06-01

    LC- ESI- MS/MS simultaneous bioanalytical method was developed to determine acitretin and its metabolite isoacitretin in human plasma using acitretin-d3 used as the internal standard for both analytes. The compounds were extracted using protein precipitation coupled with liquid-liquid extraction with flash freezing technique. Negative mass transitions (m/z) of acitretin, isoacitretin and acitretin-d3 were detected in multiple reactions monitoring (MRM) mode at 325.4 → 266.3, 325.2 → 266.1 and 328.3 → 266.3, respectively, with a turbo ion spray interface. The chromatographic separation was achieved on an Ascentis-RP amide column (4.6 × 150 mm, 5 µm) with mobile phase delivered in isocratic mode. The method was validated over a concentration range of 1.025-753.217 ng/mL for acitretin and 0.394-289.234 ng/mL for isoacitretin with a limit of quantification of 1.025 and 0.394 ng/mL. The intra-day and inter-day precisions were below 8.1% for acitretin and below 13.8% for isoacitretin, while accuracy was within ±7.0 and ±10.6% respectively. For the first time, the best possible conditions for plasma stability of acitretin and isoacitretin are presented and discussed with application to clinical samples. Copyright © 2010 John Wiley & Sons, Ltd.

  19. Development and validation of a stability-indicating RP-HPLC method for determination of atomoxetine hydrochloride in tablets.

    PubMed

    Patel, Sejal K; Patel, Natvarlal J

    2010-01-01

    This paper describes the development of a stability-indicating RP-HPLC method for the determination of atomoxetine hydrochloride (ATX) in the presence of its degradation products generated from forced decomposition studies. The drug substance was subjected to stress conditions of acid, base, oxidation, wet heat, dry heat, and photodegradation. In stability tests, the drug was susceptible to acid, base, oxidation, and dry and wet heat degradation. It was found to be stable under the photolytic conditions tested. The drug was successfully separated from the degradation products formed under stress conditions on a Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) by using acetonitrile-methanol-0.032 M ammonium acetate (55 + 05 + 40, v/v/v) as the mobile phase at 1.0 mL/min and 40 degrees C. Photodiode array detection at 275 nm was used for quantitation after RP-HPLC over the concentration range of 0.5-5 microg/mL with a mean recovery of 100.8 +/- 0.4% for ATX. Statistical analysis demonstrated that the method is repeatable, specific, and accurate for the estimation of ATX. Because the method effectively separates the drug from its degradation products, it can be used as a stability-indicating method.

  20. COMPUTATIONAL MODELING OF CATHODIC LIMITATIONS ON LOCALIZED CORROSION OF WETTED SS 316L, AT ROOM TEMPERATURE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    F. Cui; F.J. Presuel-Moreno; R.G. Kelly

    2005-10-13

    The ability of a SS316L surface wetted with a thin electrolyte layer to serve as an effective cathode for an active localized corrosion site was studied computationally. The dependence of the total net cathodic current, I{sub net}, supplied at the repassivation potential E{sub rp} (of the anodic crevice) on relevant physical parameters including water layer thickness (WL), chloride concentration ([Cl{sup -}]) and length of cathode (Lc) were investigated using a three-level, full factorial design. The effects of kinetic parameters including the exchange current density (i{sub o,c}) and Tafel slope ({beta}{sub c}) of oxygen reduction, the anodic passive current density (i{submore » p}) (on the cathodic surface), and E{sub rp} were studied as well using three-level full factorial designs of [Cl{sup -}] and Lc with a fixed WL of 25 {micro}m. The study found that all the three parameters WL, [Cl{sup -}] and Lc as well as the interactions of Lc x WL and Lc x [Cl{sup -}] had significant impact on I{sub net}. A five-factor regression equation was obtained which fits the computation results reasonably well, but demonstrated that interactions are more complicated than can be explained with a simple linear model. Significant effects on I{sub net} were found upon varying either i{sub o,c}, {beta}{sub c}, or E{sub rp}, whereas i{sub p} in the studied range was found to have little impact. It was observed that I{sub net} asymptotically approached maximum values (I{sub max}) when Lc increased to critical minimum values. I{sub max} can be used to determine the stability of coupled localized corrosion and the critical Lc provides important information for experimental design and corrosion protection.« less

  1. Preparation and characterization of two new forced degradation products of letrozole and development of a stability-indicating RP-LC method for its determination.

    PubMed

    Elkady, Ehab Farouk; Fouad, Marwa Ahmed

    2015-11-01

    Two new hydrolytic products of letrozole were identified and proved to be true degradation products obtained by alkaline and acidic degradation of the drug. The acid and amide forms of the nitrile groups of letrozole were prepared and identified by IR and mass spectroscopic techniques. Subsequently, a simple, precise and selective stability-indicating RPLC method was developed and validated for the determination of letrozole in the presence of its degradation products. Letrozole was subjected to alkali and acid hydrolysis, oxidation, thermal degradation and photo-degradation. The degradation products were well isolated from letrozole. The chromatographic method was achieved using gradient elution of the drug and its degradation products on a reversed phase Zorbax Eclipse C18 column (100mm x 4.6mm, 3.5 μm) using a mobile phase consisting of 0.01M KH₂PO₄and methanol at a flow rate of 1 mL min⁻¹. Quantitation was achieved with UV detection at 230 nm. Linearity, accuracy and precision were found to be acceptable over the concentration range of 0.01-80 μgmL⁻¹. The proposed method was successfully applied to the determination of letrozole in bulk, plasma and in its pharmaceutical preparation.

  2. Development and Validation of a Stability-Indicating RP-HPLC Method for Duloxetine Hydrochloride in its Bulk and Tablet Dosage Form

    PubMed Central

    Chhalotiya, Usmangani K.; Bhatt, Kashyap K.; Shah, Dimal A.; Baldania, Sunil L.

    2010-01-01

    The objective of the present work was to develop a stability-indicating RP-HPLC method for duloxetine hydrochloride (DUL) in the presence of its degradation products generated from forced decomposition studies. The drug substance was found to be susceptible to stress conditions of acid hydrolysis. The drug was found to be stable to dry heat, photodegradation, oxidation and basic condition attempted. Successful separation of the drug from the degradation products formed under acidic stress conditions was achieved on a Hypersil C-18 column (250 mm × 4.6 mm id, 5μm particle size) using acetonitrile: 0.01 M potassium dihydrogen phosphate buffer (pH 5.4 adjusted with orthophosphoric acid) (50:50, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Quantification was achieved with photodiode array detection at 229 nm over the concentration range 1–25 μg/ml with range of recovery 99.8–101.3 % for DUL by the RP-HPLC method. Statistical analysis proved the method to be repeatable, specific, and accurate for estimation of DUL. It can be used as a stability-indicating method due to its effective separation of the drug from its degradation products, PMID:21179321

  3. Influence of the physical state of phospholipid monolayers on protein binding.

    PubMed

    Boisselier, Élodie; Calvez, Philippe; Demers, Éric; Cantin, Line; Salesse, Christian

    2012-06-26

    Langmuir monolayers were used to characterize the influence of the physical state of phospholipid monolayers on the binding of protein Retinis Pigmentosa 2 (RP2). The binding parameters of RP2 (maximum insertion pressure (MIP), synergy and ΔΠ(0)) in monolayers were thus analyzed in the presence of phospholipids bearing increasing fatty acyl chain lengths at temperatures where their liquid-expanded (LE), liquid-condensed (LC), or solid-condensed (SC) states can be individually observed. The data show that a larger value of synergy is observed in the LC/SC states than in the LE state, independent of the fatty acyl chain length of phospholipids. Moreover, both the MIP and the ΔΠ(0) increase with the fatty acyl chain length when phospholipids are in the LC/SC state, whereas those binding parameters remain almost unchanged when phospholipids are in the LE state. This effect of the phospholipid physical state on the binding of RP2 was further demonstrated by measurements performed in the presence of a phospholipid monolayer showing a phase transition from the LE to the LC state at room temperature. The data collected are showing that very similar values of MIP but very different values of synergy and ΔΠ(0) are obtained in the LE (below the phase transition) and LC (above the phase transition) states. In addition, the binding parameters of RP2 in the LE (below the phase transition) as well as in the LC (above the phase transition) states were found to be indistinguishable from those where single LC and LE states are respectively observed. The preference of RP2 for binding phospholipids in the LC state was then confirmed by the observation of a large modification of the shape of the LC domains in the phase transition. Therefore, protein binding parameters can be strongly influenced by the physical state of phospholipid monolayers. Moreover, measurements performed with the α/β domain of RP2 strongly suggest that the β helix of RP2 plays a major role in the preferential binding of this protein to phospholipids in the LC state.

  4. New Stability Indicating RP-HPLC Method for the Estimation of Cefpirome Sulphate in Bulk and Pharmaceutical Dosage Forms.

    PubMed

    Rao, Kareti Srinivasa; Kumar, Keshar Nargesh; Joydeep, Datta

    2011-01-01

    A simple stability indicating reversed-phase HPLC method was developed and subsequently validated for estimation of Cefpirome sulphate (CPS) present in pharmaceutical dosage forms. The proposed RP-HPLC method utilizes a LiChroCART-Lichrosphere100, C18 RP column (250 mm × 4mm × 5 μm) in an isocratic separation mode with mobile phase consisting of methanol and water in the proportion of 50:50 % (v/v), at a flow rate 1ml/min, and the effluent was monitored at 270 nm. The retention time of CPS was 2.733 min and its formulation was exposed to acidic, alkaline, photolytic, thermal and oxidative stress conditions, and the stressed samples were analyzed by the proposed method. The described method was linear over a range of 0.5-200μg/ml. The percentage recovery was 99.46. F-test and t-test at 95% confidence level were used to check the intermediate precision data obtained under different experimental setups; the calculated value was found to be less than the critical value.

  5. NEW SCX PEPTIDE ELUTION SCORE FOR PH/SALT-GRADIENT SCX CHROMATOGRAPHY IN 2D-NANO-LC/MSMS ANALYSIS OF PROTEIN DIGESTS

    EPA Science Inventory

    A new automated 2D-(SCX/RP)-nano-LC/MSMS method was developed. Separation of the peptides in the first LC dimension was the main focus of this work, and it was optimized using human serum albumin (HSA) and human lung cell lysate tryptic digests. Samples were reduced and alkylated...

  6. Analytical Stability-Indicating Methods for Alogliptin in Tablets by LC-CAD and LC-UV.

    PubMed

    Bertol, Charise Dallazem; Friedrich, Maria Tereza; Carlos, Graciela; Froehlich, Pedro Eduardo

    2017-03-01

    Stability-indicating LC methods using a UV detector and a charged aerosol detector (CAD) simultaneously were validated for the assessment of alogliptin (ALG) in tablets. The analysis was performed on a C8 column (250 × 4.6 mm, 5 μm) at a flow of 0.8 mL/min, using acetonitrile-10 mM ammonium acetate buffer (pH 3.5; 90 + 10, v/v) as mobile phase and UV detection at 275 nm. Validation followed the International Conference on Harmonization guidelines. The method was linear over the range of 25-200 μg/mL. Normality of the residuals showed a normal distribution, no autocorrelation, and homoscedasticity. LODs were 6.25 and 2.65 µg/mL and LOQs were 20.85 and 8.84 µg/mL for the CAD and the UV detector, respectively. The methods were precise and accurate. Excipients and degradation products did not interfere in the methods in studies of specificity. None of the factors studied in the analysis of robustness had a significant effect on the quantification of the ALG by the Pareto chart. The results of the assay obtained with LC-CAD and LC-UV were similar. The methods could be considered interchangeable and stability-indicating, and can be applied as an appropriate QC tool for analysis of ALG in tablets.

  7. Development of Two Analytical Methods Based on Reverse Phase Chromatographic and SDS-PAGE Gel for Assessment of Deglycosylation Yield in N-Glycan Mapping.

    PubMed

    Eckard, Anahita D; Dupont, David R; Young, Johnie K

    2018-01-01

    N -lined glycosylation is one of the critical quality attributes (CQA) for biotherapeutics impacting the safety and activity of drug product. Changes in pattern and level of glycosylation can significantly alter the intrinsic properties of the product and, therefore, have to be monitored throughout its lifecycle. Therefore fast, precise, and unbiased N -glycan mapping assay is desired. To ensure these qualities, using analytical methods that evaluate completeness of deglycosylation is necessary. For quantification of deglycosylation yield, methods such as reduced liquid chromatography-mass spectrometry (LC-MS) and reduced capillary gel electrophoresis (CGE) have been commonly used. Here we present development of two additional methods to evaluate deglycosylation yield: one based on LC using reverse phase (RP) column and one based on reduced sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE gel) with offline software (GelAnalyzer). With the advent of rapid deglycosylation workflows in the market for N -glycan profiling replacing overnight incubation, we have aimed to quantify the level of deglycosylation in a selected rapid deglycosylation workflow. Our results have shown well resolved peaks of glycosylated and deglycosylated protein species with RP-LC method allowing simple quantification of deglycosylation yield of protein with high confidence. Additionally a good correlation, ≥0.94, was found between deglycosylation yields estimated by RP-LC method and that of reduced SDS-PAGE gel method with offline software. Evaluation of rapid deglycosylation protocol from GlycanAssure™ HyPerformance assay kit performed on fetuin and RNase B has shown complete deglycosylation within the recommended protocol time when evaluated with these techniques. Using this kit, N -glycans from NIST mAb were prepared in 1.4 hr and analyzed by hydrophilic interaction chromatography (HILIC) ultrahigh performance LC (UHPLC) equipped with a fluorescence detector (FLD). 37 peaks were resolved with good resolution. Excellent sample preparation repeatability was found with relative standard deviation (RSD) of <5% for peaks with >0.5% relative area.

  8. Annotation of the human serum metabolome by coupling three liquid chromatography methods to high-resolution mass spectrometry.

    PubMed

    Boudah, Samia; Olivier, Marie-Françoise; Aros-Calt, Sandrine; Oliveira, Lydie; Fenaille, François; Tabet, Jean-Claude; Junot, Christophe

    2014-09-01

    This work aims at evaluating the relevance and versatility of liquid chromatography coupled to high resolution mass spectrometry (LC/HRMS) for performing a qualitative and comprehensive study of the human serum metabolome. To this end, three different chromatographic systems based on a reversed phase (RP), hydrophilic interaction chromatography (HILIC) and a pentafluorophenylpropyl (PFPP) stationary phase were used, with detection in both positive and negative electrospray modes. LC/HRMS platforms were first assessed for their ability to detect, retain and separate 657 metabolite standards representative of the chemical families occurring in biological fluids. More than 75% were efficiently retained in either one LC-condition and less than 5% were exclusively retained by the RP column. These three LC/HRMS systems were then evaluated for their coverage of serum metabolome. The combination of RP, HILIC and PFPP based LC/HRMS methods resulted in the annotation of about 1328 features in the negative ionization mode, and 1358 in the positive ionization mode on the basis of their accurate mass and precise retention time in at least one chromatographic condition. Less than 12% of these annotations were shared by the three LC systems, which highlights their complementarity. HILIC column ensured the greatest metabolome coverage in the negative ionization mode, whereas PFPP column was the most effective in the positive ionization mode. Altogether, 192 annotations were confirmed using our spectral database and 74 others by performing MS/MS experiments. This resulted in the formal or putative identification of 266 metabolites, among which 59 are reported for the first time in human serum. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Stability-Indicating TLC-Densitometric and HPLC Methods for the Simultaneous Determination of Piracetam and Vincamine in the Presence of Their Degradation Products.

    PubMed

    Ahmed, Amal B; Abdelrahman, Maha M; Abdelwahab, Nada S; Salama, Fathy M

    2016-11-01

    Newly established TLC-densitometric and RP-HPLC methods were developed and validated for the simultaneous determination of Piracetam (PIR) and Vincamine (VINC) in their pharmaceutical formulation and in the presence of PIR and VINC degradation products, PD and VD, respectively. The proposed TLC-densitometric method is based on the separation and quantitation of the studied components using a developing system that consists of chloroform-methanol-glacial acetic acid-triethylamine (8 + 2 + 0.1 + 0.1, v/v/v/v) on TLC silica gel 60 F254 plates, followed by densitometric scanning at 230 nm. On the other hand, the developed RP-HPLC method is based on the separation of the studied components using an isocratic elution of 0.05 M KH2PO4 (containing 0.1% triethylamine adjusted to pH 3 with orthophosphoric acid)-methanol (95 + 5, v/v) on a C8 column at a flow rate of 1 mL/min with diode-array detection at 230 nm. The developed methods were validated according to International Conference on Harmonization guidelines and demonstrated good accuracy and precision. Moreover, the developed TLC-densitometric and RP-HPLC methods are suitable as stability-indicating assay methods for the simultaneous determination of PD and VD either in bulk powder or pharmaceutical formulation. The results were statistically compared with those obtained by the reported RP-HPLC method using t- and F-tests.

  10. Effect of first dimension phase selectivity in online comprehensive two dimensional liquid chromatography (LC × LC)

    PubMed Central

    Gu, Haiwei; Huang, Yuan; Filgueira, Marcelo; Carr, Peter W.

    2012-01-01

    In this study, we examined the effect of first dimension column selectivity in reversed phase (RP) online comprehensive two dimensional liquid chromatography (LC × LC). The second dimension was always a carbon clad metal oxide reversed phase material. The hydrophobic subtraction model (HSM) and the related phase selective triangles were used to guide the selection of six different RP first dimension columns. Various kinds of samples were investigated and thus two different elution conditions were needed to cause full elution from the first dimension columns. We compared LC × LC chromatograms, contours plots, and fcoverage plots by measuring peak capacities, peak numbers, relative spatial coverage, correlation values, etc. The major finding of this study is that the carbon phase due to its rather different selectivity from other reversed phases is reasonably orthogonal to a variety of common types of bonded reversed phases. Thus quite surprisingly the six different first dimension stationary phases all showed generally similar separation patterns when paired to the second dimension carbon phase. This result greatly simplifies the task of choosing the correct pair of phases for RP × RP. PMID:21840009

  11. Estimation of simvastatin and cetirizine by RP-LC method: Application to freeze and thaw (FT) stability studies.

    PubMed

    Naveed, Safila; Usmanghani, Khan; Sana, Aisha; Ali, Huma; Zafar, Farya; Qamar, Fatima; Sarwer, Ghulam; Abbas, Sarah; Alam, M Tanweer; Shinwari, Muhammad Ibrar

    2018-01-01

    Sensitive, simple, reliable and rapid HPLC technique for the estimation of simvastatin (SMV) and cetirizine has been designed in this study. The chromatographic conditions were set using Shimadzu LC-10 AT VP pump, with UV detector (SPD-10 AV-VP). System integration was performed with CBM-102 (Bus Module). Partitioning of components was attained with pre-packed C-18 column of Purospher Star (5 μm, 250 x 4.6 mm) at ambient conditions. Injected volume of sample was 10 μl. Mobile phase was composed of 50:50 v/v ratio of Acetonitrile/water (pH 3.0 adjusted with ortho-phosphoric acid) having 2 ml/minutes rate of flow. Compounds were detected in UV region at 225 nm. Percent Recovery of simvastatin was observed in the range of 98-102%. All results were found in accept table range of specification. The projected method is consistent, specific, precise, and rapid, that can be employed to quantitate the SMV along with cetirizine HCl. It was estimated by 3 successive cycles of freeze and thaw stability. Results of FT samples were found within accept table limits the method was developed and validated in raw materials, bulk formulations and final drug products.

  12. LC-UV/MS methods for the analysis of prochelator - boronyl salicylaldehyde isonicotinoyl hydrazone (BSIH) and its active chelator salicylaldehyde isonicotinoyl hydrazone (SIH)

    PubMed Central

    Bureš, Jan; Jansová, Hana; Stariat, Ján; Filipský, Tomáš; Mladěnka, Přemysl; Šimůnek, Tomáš; Kučera, Radim; Klimeš, Jiří; Wang, Qin; Franz, Katherine J.; Kovaříková, Petra

    2015-01-01

    Salicylaldehyde isonicotinoyl hydrazone (SIH) is an intracellular iron chelator with well documented potential to protect against oxidative injury both in vitro and in vivo. However, it suffers from short biological half-life caused by fast hydrolysis of the hydrazone bond. Recently, a concept of boronate prochelators has been introduced as a strategy that might overcome these limitations. This study presents two complementary analytical methods for detecting the prochelator BSIH (boronyl salicylaldehyde isonicotinoyl hydrazone) along with its active metal-binding chelator SIH in different solution matrices and concentration ranges. An LC-UV method for determination of BSIH and SIH in buffer and cell culture medium was validated over concentrations of 7 – 115 and 4 – 115 μM, respectively, and applied to BSIH activation experiments in vitro. An LC-MS assay was validated for quantification of BSIH and SIH in plasma over the concentration range of 0.06 – 23 and 0.24 – 23 μM, respectively, and applied to stability studies in plasma in vitro as well as analysis of plasma taken after i.v. administration of BSIH to rats. A Zorbax-RP bonus column and mobile phases containing either phosphate buffer with EDTA or ammonium formate and methanol/acetonitrile mixture provided suitable conditions for the LC-UV and LC-MS analysis, respectively. Samples were diluted or precipitated with methanol prior to analysis. These separative analytical techniques establish the first validated protocols to investigate BSIH activation by hydrogen peroxide in multiple matrices, directly compare the stabilities of the prochelator and chelator in plasma, and provide the first basic pharmacokinetic data of this prochelator. Experiments reveal that BSIH is stable in all media tested and is partially converted to SIH by H2O2. The observed integrity of BSIH in plasma samples from the in vivo study suggest that the concept of prochelation might be a promising strategy for further development of aroylhydrazone cytoprotective agents. PMID:25527982

  13. Gradient RP-HPLC method for the determination of potential impurities in atazanavir sulfate.

    PubMed

    Chitturi, Sreenivasa Rao; Somannavar, Yallappa Somappa; Peruri, Badarinadh Gupta; Nallapati, Sreenivas; Sharma, Hemant Kumar; Budidet, Shankar Reddy; Handa, Vijay Kumar; Vurimindi, Hima Bindu

    2011-04-28

    This paper proposes a simple and selective RP-HPLC method for the determination of process impurities and degradation products (degradants) of atazanavir sulfate (ATV) drug substance. Chromatographic separation was achieved on Ascentis(®) Express C8, (150mm×4.6mm, 2.7μm) column thermostated at 30°C under gradient elution by a binary mixture of potassium dihydrogen phosphate (pH 3.5, 0.02M) and ACN at a flow rate of 1.0ml/min. A photodiode array (PDA) detector set at 250nm was used for detection. Stress testing (forced degradation) of ATV was carried out under acidic, alkaline, oxidative, photolytic, thermal and humidity conditions. In presence of alkali, ATV transformed into cyclized products and the order of degradation reaction is determined by the method of initial rates. The unknown process impurities and alkaline degradants are isolated by preparative LC and characterized by ESI-MS/MS, (1)H NMR, and FT-IR spectral data. The developed method is validated with respect to sensitivity (lod and loq), linearity, precision, accuracy and robustness and can be implemented for routine quality control analysis and stability testing of ATV. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Improvement of a stability-indicating method by Quality-by-Design versus Quality-by-Testing: a case of a learning process.

    PubMed

    Hubert, C; Lebrun, P; Houari, S; Ziemons, E; Rozet, E; Hubert, Ph

    2014-01-01

    The understanding of the method is a major concern when developing a stability-indicating method and even more so when dealing with impurity assays from complex matrices. In the presented case study, a Quality-by-Design approach was applied in order to optimize a routinely used method. An analytical issue occurring at the last stage of a long-term stability study involving unexpected impurities perturbing the monitoring of characterized impurities needed to be resolved. A compliant Quality-by-Design (QbD) methodology based on a Design of Experiments (DoE) approach was evaluated within the framework of a Liquid Chromatography (LC) method. This approach allows the investigation of Critical Process Parameters (CPPs), which have an impact on Critical Quality Attributes (CQAs) and, consequently, on LC selectivity. Using polynomial regression response modeling as well as Monte Carlo simulations for error propagation, Design Space (DS) was computed in order to determine robust working conditions for the developed stability-indicating method. This QbD compliant development was conducted in two phases allowing the use of the Design Space knowledge acquired during the first phase to define the experimental domain of the second phase, which constitutes a learning process. The selected working condition was then fully validated using accuracy profiles based on statistical tolerance intervals in order to evaluate the reliability of the results generated by this LC/ESI-MS stability-indicating method. A comparison was made between the traditional Quality-by-Testing (QbT) approach and the QbD strategy, highlighting the benefit of this QbD strategy in the case of an unexpected impurities issue. On this basis, the advantages of a systematic use of the QbD methodology were discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Development and Validation of a Stability-Indicating Assay of Etofenamate by RP-HPLC and Characterization of Degradation Products

    PubMed Central

    Peraman, Ramalingam; Nayakanti, Devanna; Dugga, Hari Hara Theja; Kodikonda, Sudhakara

    2013-01-01

    A validated stability-indicating RP-HPLC method for etofenamate (ETF) was developed by separating its degradation products on a C18 (250 mm × 4.6 mm 5 μm) Qualisil BDS column using a phosphate buffer (pH-adjusted to 6.0 with orthophosphoric acid) and methanol in the ratio of 20:80 % v/v as the mobile phase at a flow rate of 1.0 mL/min. The column effluents were monitored by a photodiode array detector set at 286 nm. The method was validated in terms of specificity, linearity, accuracy, precision, detection limit, quantification limit, and robustness. Forced degradation of etofenamate was carried out under acidic, basic, thermal, photo, and peroxide conditions and the major degradation products of acidic and basic degradation were isolated and characterized by 1H-NMR, 13C-NMR, and mass spectral studies. The mass balance of the method varied between 92–99%. PMID:24482770

  16. [Separation and identification of bovine lactoferricin by high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/ time of flight mass spectrometry].

    PubMed

    An, Meichen; Liu, Ning

    2010-02-01

    A high performance liquid chromatography-matrix-assisted laser desorption/ionization time of flight/time of flight mass spectrometry (HPLC-MALDI-TOF/TOF MS) method was developed for the separation and identification of bovine lactoferricin (LfcinB). Bovine lactoferrin was hydrolyzed by pepsin and then separated by ion exchange chromatography and reversed-phase liquid chromatography (RP-LC). The antibacterial activities of the fractions from RP-LC separation were determined and the protein concentration of the fraction with the highest activity was measured, whose sequence was indentified by MALDI-TOF/TOF MS. The relative molecular mass of LfcinB was 3 124.89 and the protein concentration was 18.20 microg/mL. The method of producing LfcinB proposed in this study has fast speed, high accuracy and high resolution.

  17. Comprehensive two-dimensional liquid chromatography of therapeutic monoclonal antibody digests.

    PubMed

    Vanhoenacker, Gerd; Vandenheede, Isabel; David, Frank; Sandra, Pat; Sandra, Koen

    2015-01-01

    Comprehensive two-dimensional liquid chromatography (LC×LC) is here proposed as a novel tool for peptide mapping of therapeutic monoclonal antibodies in both R&D and routine (QA/QC) environments. This is illustrated by the analysis of the tryptic digest of trastuzumab (Herceptin) applying a commercially available two-dimensional 2D-LC system. Three different LC×LC combinations, i.e., strong cation-exchange × reversed-phase (SCX×RP), reversed-phase × reversed-phase (RP×RP), and hydrophilic interaction × reversed-phase (HILIC×RP), are reported. Detection was carried out using both UV detection (DAD) and mass spectrometry (MS). Several challenges related to the application of LC×LC in peptide mapping and the hyphenation to MS are addressed. The applicability of LC×LC in the assessment of identity, purity, and comparability is demonstrated by the analysis of different Herceptin innovator production batches, a Herceptin biosimilar in development and of stressed samples. The described methodology was shown to be precise in terms of peak volume and (2)D retention time opening interesting perspectives for use in QA/QC testing.

  18. Development and validation of a highly sensitive LC-ESI-MS/MS method for estimation of IIIM-MCD-211, a novel nitrofuranyl methyl piperazine derivative with potential activity against tuberculosis: Application to drug development.

    PubMed

    Magotra, Asmita; Sharma, Anjna; Gupta, Ajai Prakash; Wazir, Priya; Sharma, Shweta; Singh, Parvinder Pal; Tikoo, Manoj Kumar; Vishwakarma, Ram A; Singh, Gurdarshan; Nandi, Utpal

    2017-08-15

    In the present study, a simple, sensitive, specific and rapid liquid chromatography (LC) tandem mass spectrometry (MS/MS) method was developed and validated according to the Food and Drug Administration (FDA) guidelines for estimation of IIIM-MCD-211 (a potent oral candidate with promising action against tuberculosis) in mice plasma using carbamazepine as internal standard (IS). Bioanalytical method consisted of one step protein precipitation for sample preparation followed by quantitation in LC-MS/MS using positive electrospray ionization technique (ESI) operating in multiple reaction monitoring (MRM) mode. Elution was achieved in gradient mode on High Resolution Chromolith RP-18e column with mobile phase comprised of acetonitrile and 0.1% (v/v) formic acid in water at the flow rate of 0.4mL/min. Precursor to product ion transitions (m/z 344.5/218.4 and m/z 237.3/194.2) were used to measure analyte and IS, respectively. All validation parameters were well within the limit of acceptance criteria. The method was successfully applied to assess the pharmacokinetics of the candidate in mice following oral (10mg/kg) and intravenous (IV; 2.5mg/kg) administration. It was also effectively used to quantitate metabolic stability of the compound in mouse liver microsomes (MLM) and human liver microsomes (HLM) followed by its in-vitro-in-vivo extrapolation. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Validation and use of three complementary analytical methods (LC-FLS, LC-MS/MS and ICP-MS) to evaluate the pharmacokinetics, biodistribution and stability of motexafin gadolinium in plasma and tissues.

    PubMed

    Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W

    2006-05-01

    Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.

  20. CHARACTERIZATION OF DANSYLATED CYSTEINE, GLUTATHIONE DISULFIDE, CYSTEINE AND CYSTINE BY NARROW BORE LIQUID CHROMATOGRAPHY/ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    EPA Science Inventory

    A method using reversed phase high performance liquid chromatography/electrospray ionization-mass spectrometric (RP-LC/ESI-MS) method has been developed to confirm the identity of dansylated derivatives of cysteine and glutathione, and their respective dimers. Cysteine, GSH, CSSC...

  1. Comprehensive Two-Dimensional Hydrophilic Interaction Chromatography (HILIC) × Reversed-Phase Liquid Chromatography Coupled to High-Resolution Mass Spectrometry (RP-LC-UV-MS) Analysis of Anthocyanins and Derived Pigments in Red Wine.

    PubMed

    Willemse, Chandré M; Stander, Maria A; Vestner, Jochen; Tredoux, Andreas G J; de Villiers, André

    2015-12-15

    Changes in anthocyanin chemistry represent some of the most important transformations involved in red wine aging. However, accurate analysis of the derived pigments, as required to study the evolution of anthocyanins and tannins during aging, is hampered by their extreme structural diversity, low levels, and the fact that many of these compounds have identical mass spectral characteristics. In this context, chromatographic separation is critical. In this contribution, the application of online hydrophilic interaction chromatography (HILIC) × reversed-phase liquid chromatography (RP-LC) separation coupled to high-resolution mass spectrometry (MS) is described for the detailed characterization of anthocyanins and their derived pigments in aged red wine. A systematic approach was followed for the optimization of HILIC × RP-LC separation parameters using a capillary liquid chromatography (LC) system in the first dimension and an ultrahigh-pressure LC system in the second dimension to ensure maximum sensitivity and performance. Ninety four (94) anthocyanin-derived pigments were tentatively identified in one- and six-year-old Pinotage wines using accurate mass and fragmentation information obtained using quadrupole-time-of-flight mass spectrometry (Q-TOF-MS). Online HILIC × RP-LC-MS was found to offer high-resolution separation, because of the combination of two different separation modes, while the structured elution order observed improved the certainty in compound identification. Therefore, this approach shows promise for the detailed elucidation of the chemical alteration of anthocyanins during wine aging.

  2. N-linked glycoprotein analysis using dual-extraction ultrahigh-performance liquid chromatography and electrospray tandem mass spectrometry.

    PubMed

    Siu, S O; Lam, Maggie P Y; Lau, Edward; Yeung, William S B; Cox, David M; Chu, Ivan K

    2010-01-01

    Although reverse-phase liquid chromatography (RP-LC) is a common technique for peptide separation in shotgun proteomics and glycoproteomics, it often provides unsatisfactory results for the analysis of glycopeptides and glycans. This bias against glycopeptides makes it difficult to study glycoproteins. By coupling mass spectrometry (MS) with a combination of RP-LC and normal-phase (NP)-LC as an integrated front-end separation system, we demonstrate that effective identification and characterization of both peptides and glycopeptides mixtures, and their constituent glycan structures, can be achieved from a single sample injection event.

  3. SFC-MS/MS as an orthogonal technique for improved screening of polar analytes in anti-doping control.

    PubMed

    Parr, Maria Kristina; Wuest, Bernhard; Naegele, Edgar; Joseph, Jan F; Wenzel, Maxi; Schmidt, Alexander H; Stanic, Mijo; de la Torre, Xavier; Botrè, Francesco

    2016-09-01

    HPLC is considered the method of choice for the separation of various classes of drugs. However, some analytes are still challenging as HPLC shows limited resolution capabilities for highly polar analytes as they interact insufficiently on conventional reversed-phase (RP) columns. Especially in combination with mass spectrometric detection, limitations apply for alterations of stationary phases. Some highly polar sympathomimetic drugs and their metabolites showed almost no retention on different RP columns. Their retention remains poor even on phenylhexyl phases that show different selectivity due to π-π interactions. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to HPLC may help to overcome these issues. Selected polar drugs and metabolites were analyzed utilizing SFC separation. All compounds showed sharp peaks and good retention even for the very polar analytes, such as sulfoconjugates. Retention times and elution orders in SFC are different to both RP and HILIC separations as a result of the orthogonality. Short cycle times could be realized. As temperature and pressure strongly influence the polarity of supercritical fluids, precise regulation of temperature and backpressure is required for the stability of the retention times. As CO2 is the main constituent of the mobile phase in SFC, solvent consumption and solvent waste are considerably reduced. Graphical Abstract SFC-MS/MS vs. LC-MS/MS.

  4. Blank corrections for ramped pyrolysis radiocarbon dating of sedimentary and soil organic carbon.

    PubMed

    Fernandez, Alvaro; Santos, Guaciara M; Williams, Elizabeth K; Pendergraft, Matthew A; Vetter, Lael; Rosenheim, Brad E

    2014-12-16

    Ramped pyrolysis (RP) targets distinct components of soil and sedimentary organic carbon based on their thermochemical stabilities and allows the determination of the full spectrum of radiocarbon ((14)C) ages present in a soil or sediment sample. Extending the method into realms where more precise ages are needed or where smaller samples need to be measured involves better understanding of the blank contamination associated with the method. Here, we use a compiled data set of RP measurements of samples of known age to evaluate the mass of the carbon blank and its associated (14)C signature, and to assess the performance of the RP system. We estimate blank contamination during RP using two methods, the modern-dead and the isotope dilution method. Our results indicate that during one complete RP run samples are contaminated by 8.8 ± 4.4 μg (time-dependent) of modern carbon (MC, fM ∼ 1) and 4.1 ± 5.5 μg (time-independent) of dead carbon (DC, fM ∼ 0). We find that the modern-dead method provides more accurate estimates of uncertainties in blank contamination; therefore, the isotope dilution method should be used with caution when the variability of the blank is high. Additionally, we show that RP can routinely produce accurate (14)C dates with precisions ∼100 (14)C years for materials deposited in the last 10,000 years and ∼300 (14)C years for carbon with (14)C ages of up to 20,000 years.

  5. Development of a Suitable Dissolution Method for the Combined Tablet Formulation of Atorvastatin and Ezetimibe by RP-LC Method.

    PubMed

    Ozkan Cansel, Kose; Ozgur, Esim; Sevinc, Kurbanoglu; Ayhan, Savaser; Ozkan, Sibel A; Yalcin, Ozkan

    2016-01-01

    Pharmaceutical preparations of ezetimibe and atorvastatin are generally used to regulate the lipid level in blood. It decreases the secondary events for patients with high cholesterol and clinical cardiovascular disease such as non-fatal or fatal heart attack. There is no any pharmacopoeia method available for the dissolution testing recommended by the FDA. Development of dissolution tests method is very critical parameter especially for the pharmaceutical preparations that contain Class II drugs (slightly soluble, good permeable). In the proposed method, the effects of pH and surfactant on the dissolution of poorly water soluble combined drug therapy with a different pKa values in an in vitro environment is investigated. The content of our study was designed to answer these open-ended questions. The optimized test conditions achieved under sink conditions with USP apparatus 2 at a paddle rotation speed of 75 rpm and 900 ml in 0.01 M Acetate buffer (pH= 6.8) containing 0.45% SDS as a dissolution medium. Quantification of dissolution samples were analyzed with a new fully validated RP-LC method with UV detection at 242 nm.

  6. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method

    PubMed Central

    Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R2) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R2 > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0–103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5–20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition. PMID:25452691

  7. A Study of Method Development, Validation, and Forced Degradation for Simultaneous Quantification of Paracetamol and Ibuprofen in Pharmaceutical Dosage Form by RP-HPLC Method.

    PubMed

    Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma

    2014-01-01

    A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition.

  8. Transcription of four Rhopalosiphum padi (L.) heat shock protein genes and their responses to heat stress and insecticide exposure.

    PubMed

    Li, Yuting; Zhao, Qi; Duan, Xinle; Song, Chunman; Chen, Maohua

    2017-03-01

    The bird cherry-oat aphid, Rhopalosiphum padi (L.), a worldwide destructive pest, is more heat tolerant than other wheat aphids, and it has developed resistance to different insecticides. Heat shock proteins (HSPs) play an important role in coping with environmental stresses. To investigate Hsp transcriptional responses to heat and insecticide stress, four full-length Hsp genes from R. padi (RpHsp60, RpHsc70, RpHsp70-1, and RpHsp70-2) were cloned. Four RpHsps were expressed during all R. padi developmental stages, but at varying levels. The mRNA levels of RpHsps were increased under thermal stress and reached maximal induction at a lower temperature (36°C) in the alate morph than in the apterous morph (37°C or 38°C). RpHsp expressions under heat stress suggest that RpHsp70-1 and RpHsp70-2 are inducible in both apterous and alate morphs, RpHsc70 is only heat-inducible in apterous morph, and RpHsp60 exhibits poor sensitivity to heat stress. The pretreatment at 37°C significantly increase both the survival rate and the RpHsps expression level of R. padi at subsequent lethal temperature. Under exposure to two sublethal concentrations (LC 10 and LC 30 ) of beta-cypermethrin, both RpHsp70-1 and RpHsp70-2 expressions were induced and reached a maximum 24h after exposure. In contrast, expression of RpHsp60 was not induced by either sublethal concentration of beta-cypermethrin. Moreover, the responses of RpHsp70-1 and RpHsp70-2 to heat shock were more sensitive than those to beta-cypermethrin. These results suggest that induction of RpHsp expression is related to thermal tolerance, and that RpHsp70-1 and RpHsp70-2 are the primary genes involved in the response to both heat and pesticide stress. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Functional protease profiling with reporter peptides in serum specimens of colorectal cancer patients: demonstration of its routine diagnostic applicability

    PubMed Central

    2012-01-01

    Background The progression of many solid tumors is characterized by the release of tumor-associated proteases and the detection of tumor specific proteolytic activity in serum specimens is a promising diagnostic tool in oncology. Here we describe a mass spectrometry-based functional proteomic profiling approach that tracks the ex-vivo degradation of a synthetic endoprotease substrate in serum specimens of colorectal tumor patients. Methods A reporter peptide (RP) with the amino acid sequence WKPYDAAD was synthesized that has a known cleavage site for the cysteine-endopeptidase cancer procoagulant (EC 3.4.22.26). The RP was added to serum specimens from colorectal cancer patients (n = 30), inflammatory controls (n = 30) and healthy controls (n = 30) and incubated under strictly standardized conditions. The proteolytic fragment of the RP was quantified with liquid chromatography / mass spectrometry (LC/MS). Results RP-spiking showed good intra- and inter-day reproducibility with coefficients of variation (CVs) that did not exceed a value of 10%. The calibration curve for the anchor peptide was linear in the concentration range of 0.4 – 50 μmol/L. The median concentration of the RP-fragment in serum specimens from tumor patients (TU: 17.6 μmol/L, SD 9.0) was significantly higher when compared to non-malignant inflammatory controls (IC: 11.1 μmol/L, SD 6.1) and healthy controls (HC: 10.3 μmol/L, SD 3.1). Highest area under receiver operating characteristic (AUROC) values were seen for discrimination of TU versus HC (0.89) followed by TU versus IC (0.77). IC and HC could barely be separated indicated by an AUROC value of 0.57. The proteolytic activity towards the RP was conserved in serum specimens that were kept at room temperature for up to 24 hours prior to the analysis. Conclusion The proteolytic cleavage of reporter peptides is a surrogate marker for tumor associated proteolytic activity in serum specimens of cancer patients. A simple, robust and highly reproducible LC/MS method has been developed that allows the quantification of proteolytic fragments in serum specimens. The preanalytical impact of sample handling is minimal as the tumor-associated proteolytic activity towards the reporter peptide is stable for at least up to 24 h. Taken together, the functional protease profiling shows characteristics that are in line with routinely performed diagnostic assays. Further work will focus on the identification of additional reporter peptides for the construction of a multiplex assay to increase diagnostic accuracy of the functional protease profiling. PMID:22682081

  10. Separation and analysis of phenolic acids from Salvia miltiorrhiza and its related preparations by off-line two-dimensional hydrophilic interaction chromatography×reversed-phase liquid chromatography coupled with ion trap time-of-flight mass spectrometry.

    PubMed

    Sun, Wanyang; Tong, Ling; Miao, Jingzhuo; Huang, Jingyi; Li, Dongxiang; Li, Yunfei; Xiao, Hongting; Sun, Henry; Bi, Kaishun

    2016-01-29

    Salvia miltiorrhiza (SM) is one of the most widely used Traditional Chinese Medicine. Active constituents of SM mainly contain hydrophilic phenolic acids (PAs) and lipophilic tanshinones. However, due to the existing of multiple ester bonds and unsaturated bonds in the structures, PAs have numerous chemical conversion products. Many of them are so low-abundant that hard to be separated using conventional methods. In this study, an off-line two-dimensional liquid chromatography (2D-LC) method was developed to separate PAs in SM and its related preparations. In the first dimension, samples were fractionated by hydrophilic interaction chromatography (HILIC) (Acchrom×Amide, 4.6×250mm, 5μm) mainly based on the hydrogen bonding effects. The fractions were then separated on reversed-phase liquid chromatography (RP-LC) (Acquity HSS T3, 2.1×50mm, 1.7μm) according to hydrophobicity. For the selective identification of PAs, diode array detector (DAD) and electrospray ionization tandem ion trap time-of-flight mass spectrometry (ESI-IT-TOF-MS) were employed. Practical and effective peak capacities of all the samples were greater than 2046 and 1130, respectively, with the orthogonalities ranged from 69.7% to 92.8%, which indicated the high efficiency and versatility of this method. By utilizing the data post-processing techniques, including mass defect filter, neutral loss filter and product ion filter, a total of 265 compounds comprising 196 potentially new PAs were tentatively characterized. Twelve kinds of derivatives, mainly including glycosylated compounds, O-alkylated compounds, condensed compounds and hydrolyzed compounds, constituted the novelty of the newly identified PAs. The HILIC×RP-LC/TOF-MS system expanded our understanding on PAs of S. miltiorrhiza and its related preparations, which could also benefit the separation and characterization of polar constituents in complicated herbal extracts. Copyright © 2016. Published by Elsevier B.V.

  11. CHARACTERIZATION OF DANSYLATED CYSTEINE, CYSTINE, GLUTATHIONE, AND GLUTATHIONE DISULFIDE BY NARROW BORE LIQUID CHROMATOGRAPHY - ELECTROSPRAY IONIZATION MASS SPECTROMETRY

    EPA Science Inventory

    A method using reversed phase high performance liquid chromtography/electrospray ionization-mass spectrometry (RP-LC/ESI-MS) has been developed to confirm the dientity of dansylated derivatives of cysteine (C) and glutathione (GSH), and their respective dimers, cystine (CSSC) and...

  12. Resolving the chemical heterogeneity of natural organic matter: new insights from comprehensive two-dimensional liquid chromatography.

    PubMed

    Duarte, Regina M B O; Barros, Ana C; Duarte, Armando C

    2012-08-03

    For the purpose of resolving the chemical heterogeneity of natural organic matter (NOM), comprehensive two-dimensional liquid chromatography (LC×LC) was employed for the first time to map the hydrophobicity versus molecular weight (MW) distribution of two well-known complex organic mixtures: Suwannee River Fulvic Acids (SR-FA) and Pony Lake Fulvic Acids (PL-FA). Two methods have been developed using either a conventional reversed-phase (RP) silica column or a mixed-mode hydrophilic interaction column operating under aqueous RP mode in the first dimension, and a size-exclusion column in the second dimension. The LC×LC fractions were screened on-line by UV at 254 nm, molecular fluorescence at excitation/emission wavelengths (λ(Exc)/λ(Em)) of 240/450 nm, and by evaporative light scattering. The MW distributions of these two NOM samples were further characterized by number (Mn) and weight (Mw) average MW, and by polydispersity (Mw/Mn). Findings suggest that the combination of two independent separation mechanisms is promising in extend the range of NOM separation. For the cases where NOM separation was accomplished, smaller Mw group fractions seem to be related to a more hydrophobic nature. Regardless of the detection method, the complete range of MW distribution provided by both comprehensive LC×LC methods was found to be lower than those reported in the literature. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. ESI-MSn and LC-ESI-MS studies to characterize forced degradation products of bosentan and a validated stability-indicating LC-UV method.

    PubMed

    Bansal, Gulshan; Singh, Ranjit; Saini, Balraj; Bansal, Yogita

    2013-01-01

    The present study reports the characterization of forced degradation products of bosentan and a validated stability-indicating HPLC method for the stability testing of bosentan tablets. The forced degradation was carried out under the conditions of hydrolysis, oxidation, dry heat and photolysis. The drug was found unstable in acid, alkali and oxidative media whereas stable to the hydrolysis in water, to dry heat and to photolysis. In total, six degradation products were formed in all conditions which were resolved in a single run on a C-18 column with gradient elution using ammonium acetate buffer (pH 4.5, 5.0mM), methanol and acetonitrile. Structures of all the degradation products were characterized through +ESI-MS(n) and LC-ESI-MS spectral data of bosentan as well as LC-ESI-MS spectral data of the products. The products II-VI were characterized as 6-amino-[2,2']bipyrimidinyl-4,5-diol, 6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-ol, 2-[6-amino-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yloxy]-ethanol, 4-tert-butyl-N-[6-(1-methoxyethoxy)-5-(2-methoxyphenoxy)-[2,2']-bipyrimidinyl-4-yl]-benzenesulfonamide and 4-tert-butyl-N-[6-hydroxy-5-(2-methoxyphenoxy)-[2,2']bipyrimidinyl-4-yl]-benzenesulfonamide, respectively. The peak of the product I was found to be due to two secondary degradation products which co-eluted and were characterized as β-hydroxyethyl p-tert-butylphenylsulfonate (Ia) and 2-[2-(2-hydroxyethoxy)-phenoxy]-ethanol (Ib). These products were formed due to hydrolysis of sulfonamide and alkylaryl ether and the diaryl ether linkages as well as dehydration of the primary alcohol group. The most probable degradation mechanisms were proposed. The HPLC method was found to be stability-indicating, linear (2-100 μg ml(-1)), accurate, precise, sensitive, specific, rugged and robust for quantitation of the drug. The method was applied to the stability testing of the commercially available bosentan tablets successfully. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Development and validation of a stability-indicating RP-HPLC method for assay of betamethasone and estimation of its related compounds.

    PubMed

    Fu, Qiang; Shou, Minshan; Chien, Dwight; Markovich, Robert; Rustum, Abu M

    2010-02-05

    Betamethasone (9alpha-fluoro-16beta-methylprednisolone) is one of the members of the corticosteriod family of active pharmaceutical ingredient (API), which is widely used as an anti-inflammatory agent and also as a starting material to manufacture various esters of betamethasone. A stability-indicating reverse-phase high performance liquid chromatography (RP-HPLC) method has been developed and validated which can separate and accurately quantitate low levels of 26 betamethasone related compounds. The stability-indicating capability of the method was demonstrated through adequate separation of all potential betamethasone related compounds from betamethasone and also from each other that are present in aged and stress degraded betamethasone stability samples. Chromatographic separation of betamethasone and its related compounds was achieved by using a gradient elution at a flow rate of 1.0mL/min on a ACE 3 C18 column (150mmx4.6mm, 3microm particle size, 100A pore size) at 40 degrees C. Mobile phase A of the gradient was 0.1% methanesulfonic acid in aqueous solution and mobile phase B was a mixture of tert-butanol and 1,4-dioxane (7:93, v/v). UV detection at 254nm was employed to monitor the analytes. For betamethasone 21-aldehyde, the QL and DL were 0.02% and 0.01% respectively. For betamethasone and the rest of the betamethasone related compounds, the QL and DL were 0.05% and 0.02%. The precision of betamethasone assay is 0.6% and the accuracy of betamethasone assay ranged from 98.1% to 99.9%.

  15. A validated stability indicating RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product.

    PubMed

    Venkateswarlu, Kambham; Rangareddy, Ardhgeri; Narasimhaiah, Kanaka; Sharma, Hemraj; Bandi, Naga Mallikarjuna Raja

    2017-01-01

    The main objective of present study was to develop a RP-HPLC method for estimation of Armodafinil in pharmaceutical dosage forms and characterization of its base hydrolytic product. The method was developed for Armodafinil estimation and base hydrolytic products were characterized. The separation was carried out on C18 column by using mobile phase as mixture of water and methanol (45:55%v/v). Eluents were detected at 220nm at 1ml/min. Stress studies were performed with milder conditions followed by stronger conditions so as to get sufficient degradation around 20%. A total of five degradation products were detected and separated from analyte. The linearity of the proposed method was investigated in the range of 20-120µg/ml for Armodafinil. The detection limit and quantification limit was found to be 0.01183μg/ml and 0.035µg/ml respectively. The precision % RSD was found to be less than 2% and the recovery was between 98-102%. Armodafinil was found to be more sensitive to the base hydrolysis and yielded its carboxylic acid as degradant. The developed method was stability indicating assay, suitable to quantify Armodafinil in presence of possible degradants. The drug was sensitive to acid, base &photolytic stress and resistant to thermal &oxidation.

  16. RP-HPLC Determination of Phenylalkanoids and Monoterpenoids in Rhodiola rosea and Identification by LC-ESI-TOF

    USDA-ARS?s Scientific Manuscript database

    An HPLC method permitting the simultaneous determination of fourteen compounds (phenylalkanoids and monoterpenoids) from the roots of Rhodiola rosea was developed. A separation was achieved within 35 minutes by using C-18 column material, a water/acetonitrile mobile phase, both containing 0.05% phos...

  17. Profiling of polar metabolites in biological extracts using diamond hydride-based aqueous normal phase chromatography.

    PubMed

    Callahan, Damien L; De Souza, David; Bacic, Antony; Roessner, Ute

    2009-07-01

    Highly polar metabolites, such as sugars and most amino acids are not retained by conventional RP LC columns. Without sufficient retention low concentration compounds are not detected due ion suppression and structural isomers are not resolved. In contrast, hydrophilic interaction chromatography (HILIC) and aqueous normal phase chromatography (ANP) retain compounds based on their hydrophilicity and therefore provides a means of separating highly polar compounds. Here, an ANP method based on the diamond hydride stationary phase is presented for profiling biological small molecules by LC. A rapid separation system based upon a fast gradient that delivers reproducible chromatography is presented. Approximately 1000 compounds were reproducibly detected in human urine samples and clear differences between these samples were identified. This chromatography was also applied to xylem fluid from soyabean (Glycine max) plants to which 400 compounds were detected. This method greatly increases the metabolite coverage over RP-only metabolite profiling in biological samples. We show that both forms of chromatography are necessary for untargeted comprehensive metabolite profiling and that the diamond hydride stationary phase provides a good option for polar metabolite analysis.

  18. Quantitative analysis of iridoids, secoiridoids, xanthones and xanthone glycosides in Gentiana lutea L. roots by RP-HPLC and LC-MS.

    PubMed

    Aberham, Anita; Schwaiger, Stefan; Stuppner, Hermann; Ganzera, Markus

    2007-11-05

    The here described HPLC-method enables the determination of all major, currently known bioactive compounds in gentian roots. A separation of iridoids (loganic acid), secoiridoids (swertiamarin, gentiopicroside, amarogentin, sweroside), xanthones (gentisin, isogentisin) and two xanthone glycosides (gentiosides) was possible on RP-18 column material, using 0.025% aqueous TFA, acetonitrile and n-propanol as mobile phase. The method is sensitive (LOD

  19. Characterization of Isomeric Glycans by Reversed Phase Liquid Chromatography-Electronic Excitation Dissociation Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Tang, Yang; Wei, Juan; Costello, Catherine E.; Lin, Cheng

    2018-04-01

    The occurrence of numerous structural isomers in glycans from biological sources presents a severe challenge for structural glycomics. The subtle differences among isomeric structures demand analytical methods that can provide structural details while working efficiently with on-line glycan separation methods. Although liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful tool for mixture analysis, the commonly utilized collision-induced dissociation (CID) method often does not generate a sufficient number of fragments at the MS2 level for comprehensive structural characterization. Here, we studied the electronic excitation dissociation (EED) behaviors of metal-adducted, permethylated glycans, and identified key spectral features that could facilitate both topology and linkage determinations. We developed an EED-based, nanoscale, reversed phase (RP)LC-MS/MS platform, and demonstrated its ability to achieve complete structural elucidation of up to five structural isomers in a single LC-MS/MS analysis. [Figure not available: see fulltext.

  20. Separation and characterization of allergic polymerized impurities in cephalosporins by 2D-HPSEC×LC-IT-TOF MS.

    PubMed

    Xu, Yu; Wang, DanDan; Tang, Lan; Wang, Jian

    2017-10-25

    Eleven unknown allergic impurities in cefodizime, cefmenoxime and cefonicid were separated and characterized by a trap-free two-dimensional high performance size exclusion chromatography (HPSEC) and reversed phase liquid chromatography (RP-HPLC) coupled to high resolution ion trap/time-of-flight mass spectrometry (2D-HPSEC×LC-IT-TOF MS) with positive and negative modes of electrospray ionization method. Separation and characterization the allergic polymerized impurities in β-lactam antibiotics were on the basis of column-switching technique which effectively combined the advantages of HPSEC and the ability of RP-HPLC to identify the special impurities. In the first dimension HPSEC, the column was Xtimate SEC-120 analytical column (7.8mm×30cm, 5μm), and the gradient elution used pH 7.0 buffer-acetonitrile as mobile phase And the second dimension analytical column was ZORBAX SB-C18 (4.6×150mm, 3.5μm) with ammonium formate solution (10mM) and ammonium formate (8mM) in [acetonitrile-water (4:1, v/v)] solution as mobile phase. Structures of eleven unknown impurities were deduced based on the high resolution MS n data with both positive and negative modes, in which nine impurities were polymerized impurities. The forming mechanism of β-lactam antibiotic polymerization in cephalosporins was also studied. The question on incompatibility between non-volatile salt mobile phase and mass spectrometry was solved completely by multidimensional heart-cutting approaches and online demineralization technique, which was worthy of widespread use and application for the advantages of stability and repeatability. Copyright © 2017. Published by Elsevier B.V.

  1. Analysis of iridoids, secoiridoids and xanthones in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea using LC-MS and RP-HPLC.

    PubMed

    Aberham, Anita; Pieri, Valerio; Croom, Edward M; Ellmerer, Ernst; Stuppner, Hermann

    2011-02-20

    This study presents a new and validated HPLC method for the simultaneous determination of bioactive compounds in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea. The iridoid loganic acid, four secoiridoids and 29 xanthones were separated on a RP-18 column, using aqueous o-phosphoric acid (0.085%, v/v) and acetonitrile as mobile phase. Phytochemical investigation of C. erythraea herb and F. caroliniensis roots resulted into isolation of 25 xanthones and three secoiridoids the structure of which was elucidated by spectroscopic means (NMR, MS and UV). 1,3,8-Trihydroxy-5,6-dimethoxyxanthone, isolated from C. erythraea, turned out to be a novel xanthone. The stability of the analytes was tested by subjecting samples to light, moisture and different temperatures. After six months of storage, decomposition of gentiopicroside and sweroside was observed. The swertiamarin content was nearly unchanged when stored at room temperature or in the refrigerator, but high temperature conditions reduced the content to 85%. In contrast, xanthones were stable under long-term, refrigerated and accelerated conditions. The established chromatographic method has been successfully applied for the quantification of the bioactive compounds in the three plants. The presence and distribution of polyoxygenated xanthones within the three members of the Gentianaceae family and their significance as analytical markers are discussed. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Method for the Determination of Aconitum Alkaloids in Dietary Supplements and Raw Materials by Reversed-Phase Liquid Chromatography with Ultraviolet Detection and Confirmation by Tandem Mass Spectrometry: Single-Laboratory Validation

    PubMed Central

    Tang, Wai-Tong; Wong, Sui-Kay; Law, Tin-Yau; Pang, Kwok-Chu; Sin, Della; Tam, Yin-King

    2008-01-01

    A study of single-laboratory validation (SLV) of a reversed-phase liquid Chromatography (RP-LC) method was conducted for the determination of diester-diterpene Aconitum alkaloids, viz., aconitine, mesaconitine, and hypaconitine, in a variety of dietary supplements, including single-arid multiple-ingredient dry powder extracts, pills, capsules, and raw materials. The Aconitum alkaloids in the samples were extracted by diethyl ether in the presence of ammonia. After cleanup with solid-phase extraction to remove the matrix interferences, the alkaloids were determined by RP-LC with UV detection at 235 nm, and the results were confirmed by tandem mass Spectrometry. The linear responses for aconitine, mesaconitine, and hypaconitine based on the present LC system ranged from 0.5 to 200 μg/mL. Relative standard deviations of 2.0 to 6.9% were obtained from duplicate analysis of 6 test materials of different matrixes for the 3 Aconitum alkaloids performed by 2 analysts on 5 different days. The recoveries determined for supplements and raw materials spiked with 3 Aconitum alkaloids at levels of 2.5–10 μg/g were in the range of 86–99%. In view of the attainment of satisfactory results for accuracy, precision, and recovery in the SLV study, it is recommended that the method validation process proceed to a collaborative study. PMID:17225594

  3. Assessing the biodegradability of terrestrially-derived organic matter in Scottish sea loch sediments

    NASA Astrophysics Data System (ADS)

    Loh, P. S.; Miller, A. E. J.; Reeves, A. D.; Harvey, S. M.; Overnell, J.

    2008-05-01

    Lignin oxidation products, oxygen uptake rates, molar organic carbon to nitrogen (OC/N) ratio (from bulk elemental analysis) and Rp values (from loss on ignition experiments, the ratio of the refractory to total organic matter, OM) were determined for sediments along transects of Loch Creran and Loch Etive. Lignin data indicated the importance of riverine inputs contributing to land-derived carbon in the lochs as total lignin (Λ, mg/100 mg organic carbon, OC) decreased from 0.69 to 0.45 and 0.70 to 0.29 from the head to outside of Loch Creran and Loch Etive, respectively. In addition, significant correlations of lignin content against total OM and OC (p<0.05) also suggested a distinct contribution of terrestrial OM to carbon pools in the lochs. The general trend of decreasing oxygen uptake rates from the head (20.8 mmole m-2 day-1) to mouth (9.4 mmole m-2 day-1) of Loch Creran indicates decomposition of OM. Biodegradability of the sedimentary OM was also characterized by the increase of Rp values from the head to mouth of the lochs: 0.40 to 0.80 in Loch Etive and 0.43 to 0.63 in Loch Creran. Furthermore, the molar OC/N ratio decreased from 11.2 to 6.4 in Loch Creran, and from 17.5 to 8.2 in Loch Etive. Derived rate constants for OM degradation were found to decrease from LC0 to LC1, and increase from RE5 to RE6. This work demonstrates that oxygen uptake rates, Rp values and molar OC/N ratio are able to serve as useful proxies to indicate the biodegradability of sedimentary OM.

  4. Development and validation of an HPLC-MS/MS method to determine clopidogrel in human plasma. Use of incurred samples to test back-conversion.

    PubMed

    Silvestro, Luigi; Gheorghe, Mihaela Cristina; Tarcomnicu, Isabela; Savu, Silviu; Savu, Simona Rizea; Iordachescu, Adriana; Dulea, Constanta

    2010-11-15

    Quantitative methods using LC-MS/MS allow achievement of adequate sensitivity for pharmacokinetic studies with clopidogrel; three such methods, with LLOQs as low as 5 pg/mL, were developed and fully validated according to the well established FDA 2001 guidelines. The chromatographic separations were performed on reversed phase columns Ascentis RP-Amide (15 cm x 2.1 mm, 5 μm), Ascentis Express C8 (10 cm x 2.1 mm, 2.7 μm) and Ascentis Express RP Amide (10 cm x 2.1 mm, 2.7 μm), respectively. Positive electrospray ionization in MRM mode was employed for the detection and a deuterated analogue (d3-clopidogrel) was used as internal standard. Linearity, precision, extraction recovery, matrix effects and stability tests on blank plasma spiked with clopidogrel and stored in different conditions met the acceptance criteria. During the analysis of the real samples from the first pharmacokinetic study, a significant increase (>100%) of the measured clopidogrel concentrations in the extracts kept in the autosampler at 10 °C was observed. Investigations led to the conclusion that most probably a back-conversion of one or more of the clopidogrel metabolites is occurring. The next methods were optimized in order to minimize this back-conversion. After a series of experiments, the adjustment of the sample preparation (e.g. processing at low temperature and introducing a clean-up step on Supelco HybridSPE-Precipitation cartridges) has proven to be the most effective in order to improve the stability of the extracts. Incurred samples of real subjects were successfully used in the validation of the last two analytical methods to evaluate the back-conversion, while tests using only the known metabolites could not detect this important problem. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. A New Improved RP-HPLC Method for Assay of Rosuvastatin Calcium in Tablets

    PubMed Central

    Kaila, H. O.; Ambasana, M. A.; Thakkar, R. S.; Saravaia, H. T.; Shah, A. K.

    2010-01-01

    A reliable and sensitive isocratic stability indicating RP-HPLC method has been developed and validated for assay of rosuvastatin calcium in tablets and for determination of content uniformity. An isocratic separation of rosuvastatin calcium was achieved on YMC C8, 150×4.6 mm i.d., 5 μm particle size columns with a flow rate of 1.5 ml/min and using a photodiode array detector to monitor the eluate at 242 nm. The mobile phase consisted of acetonitrile: water (40:60, v/v) pH 3.5 adjusted with phosphoric acid. The drug was subjected to oxidation, hydrolysis, photolysis and thermal degradation. All degradation products in an overall analytical run time of approximately 10 min with the parent compound rosuvastatin eluting at approximately 5.2 min. Response was a linear function of drug concentration in the range of 0.5-80 μg/ml (r2= 0.9993) with a limit of detection and quantification of 0.1 and 0.5 μg/ml respectively. Accuracy (recovery) was between 99.6 and 101.7%. Degradation products resulting from the stress studies did not interfere with the detection of rosuvastatin and the assay is thus stability-indicating. PMID:21694991

  6. A validated stability-indicating UPLC method for desloratadine and its impurities in pharmaceutical dosage forms.

    PubMed

    Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K

    2010-02-05

    A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.

  7. Functional protease profiling with reporter peptides in serum specimens of colorectal cancer patients: demonstration of its routine diagnostic applicability.

    PubMed

    Findeisen, Peter; Costina, Victor; Yepes, Diego; Hofheinz, Ralf; Neumaier, Michael

    2012-06-08

    The progression of many solid tumors is characterized by the release of tumor-associated proteases and the detection of tumor specific proteolytic activity in serum specimens is a promising diagnostic tool in oncology. Here we describe a mass spectrometry-based functional proteomic profiling approach that tracks the ex-vivo degradation of a synthetic endoprotease substrate in serum specimens of colorectal tumor patients. A reporter peptide (RP) with the amino acid sequence WKPYDAAD was synthesized that has a known cleavage site for the cysteine-endopeptidase cancer procoagulant (EC 3.4.22.26). The RP was added to serum specimens from colorectal cancer patients (n = 30), inflammatory controls (n = 30) and healthy controls (n = 30) and incubated under strictly standardized conditions. The proteolytic fragment of the RP was quantified with liquid chromatography / mass spectrometry (LC/MS). RP-spiking showed good intra- and inter-day reproducibility with coefficients of variation (CVs) that did not exceed a value of 10%. The calibration curve for the anchor peptide was linear in the concentration range of 0.4 - 50 μmol/L. The median concentration of the RP-fragment in serum specimens from tumor patients (TU: 17.6 μmol/L, SD 9.0) was significantly higher when compared to non-malignant inflammatory controls (IC: 11.1 μmol/L, SD 6.1) and healthy controls (HC: 10.3 μmol/L, SD 3.1). Highest area under receiver operating characteristic (AUROC) values were seen for discrimination of TU versus HC (0.89) followed by TU versus IC (0.77). IC and HC could barely be separated indicated by an AUROC value of 0.57. The proteolytic activity towards the RP was conserved in serum specimens that were kept at room temperature for up to 24 hours prior to the analysis. The proteolytic cleavage of reporter peptides is a surrogate marker for tumor associated proteolytic activity in serum specimens of cancer patients. A simple, robust and highly reproducible LC/MS method has been developed that allows the quantification of proteolytic fragments in serum specimens. The preanalytical impact of sample handling is minimal as the tumor-associated proteolytic activity towards the reporter peptide is stable for at least up to 24 h. Taken together, the functional protease profiling shows characteristics that are in line with routinely performed diagnostic assays. Further work will focus on the identification of additional reporter peptides for the construction of a multiplex assay to increase diagnostic accuracy of the functional protease profiling.

  8. RP-1 Thermal Stability and Copper Based Materials Compatibility Study

    NASA Technical Reports Server (NTRS)

    Stiegemeier, B. R.; Meyer, M. L.; Driscoll, E.

    2005-01-01

    A series of electrically heated tube tests was performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the effect that sulfur content, test duration, and tube material play in the overall thermal stability and materials compatibility characteristics of RP-1. Scanning-electron microscopic (SEM) analysis in conjunction with energy dispersive spectroscopy (EDS) were used to characterize the condition of the tube inner wall surface and any carbon deposition or corrosion formed during these runs. Results of the parametric study indicate that tests with standard RP-1 (total sulfur -23 ppm) and pure copper tubing are characterized by a depostion/deposit shedding process producing local wall temperature swings as high as 500 F. The effect of this shedding is to keep total carbon deposition levels relatively constant for run times from 20 minutes up to 5 hours, though increasing tube pressure drops were observed in all runs. Reduction in the total sulfur content of the fuel from 23 ppm to less than 0.1 ppm resulted in the elimination of deposit shedding, local wall temperature variation, and the tube pressure drop increases that were observed in standard sulfur level RP-1 tests. The copper alloy GRCop-84, a copper alloy developed specifically for high heat flux applications, was found to exhibit higher carbon deposition levels compared to identical tests performed in pure copper tubes. Results of the study are consistent with previously published heated tube data which indicates that small changes in fuel total sulfur content can lead to significant differences in the thermal stability of kerosene type fuels and their compatibility with copper based materials. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-1.

  9. A Simple and Specific Stability- Indicating RP-HPLC Method for Routine Assay of Adefovir Dipivoxil in Bulk and Tablet Dosage Form.

    PubMed

    Darsazan, Bahar; Shafaati, Alireza; Mortazavi, Seyed Alireza; Zarghi, Afshin

    2017-01-01

    A simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of adefovir dipivoxil (ADV).The chromatographic separation was performed on a C 18 column using a mixture of acetonitrile-citrate buffer (10 mM at pH 5.2) 36:64 (%v/v) as mobile phase, at a flow rate of 1.5 mL/min. Detection was carried out at 260 nm and a sharp peak was obtained for ADV at a retention time of 5.8 ± 0.01 min. No interferences were observed from its stress degradation products. The method was validated according to the international guidelines. Linear regression analysis of data for the calibration plot showed a linear relationship between peak area and concentration over the range of 0.5-16 μg/mL; the regression coefficient was 0.9999and the linear regression equation was y = 24844x-2941.3. The detection (LOD) and quantification (LOQ) limits were 0.12 and 0.35 μg/mL, respectively. The results proved the method was fast (analysis time less than 7 min), precise, reproducible, and accurate for analysis of ADV over a wide range of concentration. The proposed specific method was used for routine quantification of ADV in pharmaceutical bulk and a tablet dosage form.

  10. Development and validation of a novel stability-indicating HPLC method for the simultaneous assay of betamethasone-17-valerate, fusidic acid, potassium sorbate, methylparaben and propylparaben in a topical cream preparation.

    PubMed

    Byrne, Jonathan; Velasco-Torrijos, Trinidad; Reinhardt, Robert

    2014-08-05

    A novel stability-indicating reversed phase high performance liquid chromatographic (RP-HPLC) method for the simultaneous assay of betamethasone-17-valerate, fusidic acid and potassium sorbate as well as methyl- and propylparaben in a topical cream preparation has been developed. A 100mm×3.0mm ID. Ascentis Express C18 column maintained at 30°C and UV detection at 240nm were used. A gradient programme was employed at a flow-rate of 0.75ml/min. Mobile phase A comprised of an 83:17 (v/v) mixture of acetonitrile and methanol and mobile phase B of a 10g/l solution of 85% phosphoric acid in purified water. The method has been validated according to current International Conference on Harmonisation (ICH) guidelines and applied during formulation development and stability studies. The procedure has been shown to be stability-indicating for the topical cream. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS.

    PubMed

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A M; Vishwanath, K; Jadhav, R K

    2011-05-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed.

  12. Identification of Forced Degradation Products of Itopride by LC-PDA and LC-MS

    PubMed Central

    Joshi, Payal; Bhoir, Suvarna; Bhagwat, A. M.; Vishwanath, K.; Jadhav, R. K.

    2011-01-01

    Degradation products of itopride formed under different forced conditions have been identified using LC-PDA and LC-MS techniques. Itopride was subjected to forced degradation under the conditions of hydrolysis, photolysis, oxidation, dry and wet heat, in accordance with the International Conference on Harmonization. The stress solutions were chromatographed on reversed phase C18 (250×4.6 mm, 5 μm) column with a mobile phase methanol:water (55:45, v/v) at a detection wavelength of 215 nm. Itopride degraded in acid, alkali and oxidative stress conditions. The stability indicating method was developed and validated. The degradation pathway of the drug to products II-VIII is proposed. PMID:22457552

  13. Pushing quantitation limits in micro UHPLC-MS/MS analysis of steroid hormones by sample dilution using high volume injection.

    PubMed

    Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás

    2016-09-10

    Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Profiling pneumococcal type 3-derived oligosaccharides by high resolution liquid chromatography-tandem mass spectrometry

    PubMed Central

    Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J.; Avci, Fikri Y.

    2015-01-01

    Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumonia infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. PMID:25913329

  15. Profiling pneumococcal type 3-derived oligosaccharides by high resolution liquid chromatography-tandem mass spectrometry.

    PubMed

    Li, Guoyun; Li, Lingyun; Xue, Changhu; Middleton, Dustin; Linhardt, Robert J; Avci, Fikri Y

    2015-06-05

    Pneumococcal type-3 polysaccharide (Pn3P) is considered a major target for the development of a human vaccine to protect against Streptococcus pneumoniae infection. Thus, it is critical to develop methods for the preparation and analysis of Pn3P-derived oligosaccharides to better understand its immunological properties. In this paper, we profile oligosaccharides, generated by the free radical depolymerization of Pn3P, using liquid chromatography (LC)-tandem mass spectrometry (MS/MS). Hydrophilic liquid interaction chromatography (HILIC)-mass spectrometry (MS) revealed a series of oligosaccharides with an even- and odd-number of saccharide residues, ranging from monosaccharide, degree of polymerization (dp1) to large oligosaccharides up to dp 20, generated by free radical depolymerization. Isomers of oligosaccharides with an even number of sugar residues were easily separated on a HILIC column, and their sequences could be distinguished by comparing MS/MS of these oligosaccharides and their reduced alditols. Fluorescent labeling with 2-aminoacridone (AMAC) followed by reversed phase (RP)-LC-MS/MS was applied to analyze and sequence poorly separated product mixtures, as RP-LC affords higher resolution of AMAC-labeled oligosaccharides than does HILIC-based separation. The present methodology can be potentially applied to profiling other capsular polysaccharides. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Isolation, Characterization, and RP-HPLC Estimation of P-Coumaric Acid from Methanolic Extract of Durva Grass (Cynodon dactylon Linn.) (Pers.)

    PubMed Central

    Karthikeyan, Ramadoss; Devadasu, Chapala; Srinivasa Babu, Puttagunta

    2015-01-01

    P-coumaric acid is a nonflavonoid phenolic acid and is a major constituent of the species Cynodon dactylon Linn. (Pers.). In this study isolation of P-coumaric acid was achieved by preparative TLC and the compound thus isolated was characterised by UV, mass, and H1 NMR spectral analysis. An isocratic RP-HPLC method was developed for the estimation of P-coumaric acid from methanolic extracts of durva grass. The chromatographic separations were achieved by RP-C18 column (250 mm × 4.6 mm, 5 μ), Shimadzu LC-20AT Prominence liquid chromatograph, and a mobile phase composed of water : methanol : glacial acetic acid (65 : 34 : 1 v/v). The flow rate was 1.0 mL/min and the analyses of column effluents were performed using UV-visible detector at 310 nm. Retention time of P-coumaric acid was found to be 6.617 min. This method has obeyed linearity over the concentration range of 2–10 μg/mL and the regression coefficient obtained from linearity plot for P-coumaric acid was found to be 0.999. RP-HPLC method was validated in pursuance of ICH guidelines. PMID:25788944

  17. Simultaneous liquid chromatography/mass spectrometry determination of both polar and "multiresidue" pesticides in food using parallel hydrophilic interaction/reversed-phase liquid chromatography and a hybrid sample preparation approach.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2017-09-29

    Pesticide testing of foodstuffs is usually accomplished with generic wide-scope multi-residue methods based on liquid chromatography tandem mass spectrometry (LC-MS/MS). However, this approach does not cover some special pesticides, the so called "single-residue method" compounds, that are hardly compatible with standard reversed-phase (RP) separations due to their specific properties. In this article, we propose a comprehensive strategy for the integration of single residue method compounds and standard multiresidue pesticides within a single run. It is based on the use of a parallel LC column assembly with two different LC gradients performing orthogonal hydrophilic interaction chromatography (HILIC) and reversed-phase (RPLC) chromatography within one analytical run. Two sample aliquots were simultaneously injected on each column, using different gradients, being the eluents merged post-column prior to mass spectrometry detection. The approach was tested with 41 multiclass pesticides covering a wide range of physicochemical properties across several orders of log K ow (from -4 to +5.5). With this assembly, distinct separation from the void was attained for all the pesticides studied, keeping similar performance in terms of sensitivity, peak area reproducibility (<6 RSD% in most cases) and retention time stability of standard single column approaches (better than±0.1min). The application of the proposed approach using parallel HILIC/RPLC and RPLC/aqueous normal phase (Obelisc) were assessed in leek using LC-MS/MS. For this purpose, a hybrid QuEChERS (Quick, easy, cheap, effective, rugged and safe)/QuPPe (quick method for polar pesticides) method was evaluated based on solvent extraction with MeOH and acetonitrile followed by dispersive solid-phase extraction, delivering appropriate recoveries for most of the pesticides included in the study within the log K ow in the range from -4 to +5.5. The proposed strategy may be extended to other fields such as sport drug testing or environmental analysis, where the same type of variety of analytes featuring poor retention within a single chromatographic separation occurs. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Development and validation of a liquid chromatography-isotope dilution tandem mass spectrometry for determination of olanzapine in human plasma and its application to bioavailability study.

    PubMed

    Zhang, Meng-Qi; Jia, Jing-Ying; Lu, Chuan; Liu, Gang-Yi; Yu, Cheng-Yin; Gui, Yu-Zhou; Liu, Yun; Liu, Yan-Mei; Wang, Wei; Li, Shui-Jun; Yu, Chen

    2010-06-01

    A simple, reliable and sensitive liquid chromatography-isotope dilution mass spectrometry (LC-ID/MS) was developed and validated for quantification of olanzapine in human plasma. Plasma samples (50 microL) were extracted with tert-butyl methyl ether and isotope-labeled internal standard (olanzapine-D3) was used. The chromatographic separation was performed on XBridge Shield RP 18 (100 mm x 2.1 mm, 3.5 microm, Waters). An isocratic program was used at a flow rate of 0.4 m x min(-1) with mobile phase consisting of acetonitrile and ammonium buffer (pH 8). The protonated ions of analytes were detected in positive ionization by multiple reactions monitoring (MRM) mode. The plasma method, with a lower limit of quantification (LLOQ) of 0.1 ng x mL(-1), demonstrated good linearity over a range of 0.1 - 30 ng x mL(-1) of olanzapine. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were evaluated during method validation. The validated method was successfully applied to analyzing human plasma samples in bioavailability study.

  19. A validated stability-indicating LC method for the separation of enantiomer and potential impurities of Linezolid using polar organic mode.

    PubMed

    Satyanarayana Raju, T; Vishweshwari Kutty, O; Ganesh, V; Yadagiri Swamy, P

    2012-08-01

    Although a number of methods are available for evaluating Linezolid and its possible impurities, a common method for separation if its potential impurities, degradants and enantiomer in a single method with good efficiency remain unavailable. With the objective of developing an advanced method with shorter runtimes, a simple, precise, accurate stability-indicating LC method was developed for the determination of purity of Linezolid drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. This method is capable of separating all the related substances of Linezolid along with the chiral impurity. This method can also be used for the estimation of assay of Linezolid in drug substance as well as in drug product. The method was developed using Chiralpak IA (250 mm×4.6 mm, 5 μm) column. A mixture of acetonitrile, ethanol, n-butyl amine and trifluoro acetic acid in 96:4:0.10:0.16 (v/v/v/v) ratio was used as a mobile phase. The eluted compounds were monitored at 254 nm. Linezolid was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection, limit of quantification, precision, linearity, accuracy, robustness and system suitability.

  20. Development and validation of an LC-MS/MS analysis for simultaneous determination of delphinidin-3-glucoside, cyanidin-3-glucoside and cyanidin-3-(6-malonylglucoside) in human plasma and urine after blood orange juice administration.

    PubMed

    Giordano, Lucia; Coletta, Walter; Rapisarda, Paolo; Donati, Maria Benedetta; Rotilio, Domenico

    2007-12-01

    Blood orange juice has a high content in anthocyanins, especially represented by delphinidin-3-glucoside (D3G), cyanidin-3-glucoside (C3G) and cyanidin-3-(6-malonylglucoside) (CMG). An LC-MS/MS method for the simultaneous determination of D3G and C3G in human plasma and urine was developed and validated. After sample preparation by SPE, chromatographic separation was performed with an RP-C(18) column, using a water/methanol linear gradient. The quantitation of target compounds was determined by multiple reaction monitoring (MRM) mode, using ESI. The method showed good selectivity, sensitivity (LOD = 0.05 and 0.10 ng/mL for C3G in plasma and urine, respectively; LOD = 0.10 ng/mL for D3G in plasma and urine), linearity (0.20-200 ng/mL; r >or= 0.998), intra- and interday precision and accuracy (

  1. An automated online turboflow cleanup LC/MS/MS method for the determination of 11 plasticizers in beverages and milk.

    PubMed

    Ates, Ebru; Mittendorf, Klaus; Senyuva, Hamide

    2013-01-01

    An automated sample preparation technique involving cleanup and analytical separation in a single operation using an online coupled TurboFlow (RP-LC system) is reported. This method eliminates time-consuming sample preparation steps that can be potential sources for cross-contamination in the analysis of plasticizers. Using TurboFlow chromatography, liquid samples were injected directly into the automated system without previous extraction or cleanup. Special cleanup columns enabled specific binding of target compounds; higher MW compounds, i.e., fats and proteins, and other matrix interferences with different chemical properties were removed to waste, prior to LC/MS/MS. Systematic stepwise method development using this new technology in the food safety area is described. Selection of optimum columns and mobile phases for loading onto the cleanup column followed by transfer onto the analytical column and MS detection are critical method parameters. The method was optimized for the assay of 10 phthalates (dimethyl, diethyl, dipropyl, butyl benzyl, diisobutyl, dicyclohexyl, dihexyl, diethylhexyl, diisononyl, and diisododecyl) and one adipate (diethylhexyl) in beverages and milk.

  2. The Elevation of LC-ESI-Q-TOF-MS Response in the Analysis of Isoquinoline Alkaloids from Some Papaveraceae and Berberidaceae Representatives.

    PubMed

    Kukula-Koch, Wirginia

    2017-01-01

    Twenty-five methanol extracts obtained from various representatives of Papaveraceae and Berberidaceae botanical families (genera: Papaver , Argemone , Eschscholzia , Chelidonium , Glaucium , and Berberis ) were screened for their alkaloid content in an optimized method suitable for the LC-ESI-Q-TOF-MS analysis. Twelve pharmacologically important isoquinoline alkaloids from four groups, aporphines, benzylisoquinolines, protoberberines, and benzophenanthridines, present in these traditionally used plant species were quantitatively determined in each studied sample, providing their alkaloid profile. A Zorbax Stable Bond RP-18 column and a mobile phase composed of 0.1% formic acid and 0.1% formic acid in acetonitrile (v/v) were used at the flow rate of 0.2 mL/min. A profound study on the optimization of MS response to four groups of isoquinoline alkaloids (validation of capillary voltage, gas flows, nebulizer pressure, skimmer, and fragmentor voltages), repeatability of results, and stability and linearity of measurements were described, showing, among others, 3000 V of capillary voltage, 350°C of gas temperature, 12 L/min of gas flows, nebulizer pressure of 35 psig, 65 V for skimmer voltage, and 30 V for collision energy as the most advantageous operation parameters.

  3. The Elevation of LC-ESI-Q-TOF-MS Response in the Analysis of Isoquinoline Alkaloids from Some Papaveraceae and Berberidaceae Representatives

    PubMed Central

    2017-01-01

    Twenty-five methanol extracts obtained from various representatives of Papaveraceae and Berberidaceae botanical families (genera: Papaver, Argemone, Eschscholzia, Chelidonium, Glaucium, and Berberis) were screened for their alkaloid content in an optimized method suitable for the LC-ESI-Q-TOF-MS analysis. Twelve pharmacologically important isoquinoline alkaloids from four groups, aporphines, benzylisoquinolines, protoberberines, and benzophenanthridines, present in these traditionally used plant species were quantitatively determined in each studied sample, providing their alkaloid profile. A Zorbax Stable Bond RP-18 column and a mobile phase composed of 0.1% formic acid and 0.1% formic acid in acetonitrile (v/v) were used at the flow rate of 0.2 mL/min. A profound study on the optimization of MS response to four groups of isoquinoline alkaloids (validation of capillary voltage, gas flows, nebulizer pressure, skimmer, and fragmentor voltages), repeatability of results, and stability and linearity of measurements were described, showing, among others, 3000 V of capillary voltage, 350°C of gas temperature, 12 L/min of gas flows, nebulizer pressure of 35 psig, 65 V for skimmer voltage, and 30 V for collision energy as the most advantageous operation parameters. PMID:29435385

  4. High-Temperature Nucleosynthesis Processes on the Proton-Rich Side of Stability: the Alpha-Rich Freezeout and the rp^2-Process

    NASA Astrophysics Data System (ADS)

    Meyer, Bradley S.

    2001-10-01

    Nucleosynthesis on the proton-rich side of stability has at least two intriguing aspects. First, the most abundant of the stable iron-group isotopes, such as ^48Ti, ^52Cr, and ^56,57Fe, are synthesized as proton-rich, radioactive parents in alpha-rich freezeouts from equilibrium. The production of these radioactive progenitors depends in large measure on reactions on the proton-rich side of stability. The second intriguing aspect is that explosive nucleosynthesis in a hydrogen-rich environment (namely, the rp-process) may be associated with exotic astrophysical settings, such as x-ray bursts, and may be responsible for production of some of the light p-process nuclei (for example, ^92,94Mo and ^96,98Ru). We have developed web-based tools to help nuclear physicists determine which nuclear reactions on the proton-rich side of stability govern the nucleosynthesis in these processes. For the alpha-rich freezeout, one may determine the effect of any one of 2,140 reactions on the yield of any isotope in the nuclear reaction network with the web calculator. As a relevant example, I will discuss the governing role of ^57Ni (n,p)^57Co in the synthesis of the important astronomical observable ^57Co. As for explosive, proton-rich burning, I will discuss the synthesis of p-process nuclei in the repetitive rp-process (the rp^2-process). Movies of the rp^2-process illustrate its important features and give some indications of the important nuclear reactions.

  5. Stability-indicating method for simultaneous estimation of olmesartan medoxomile, amlodipine besylate and hydrochlorothiazide by RP-HPLC in tablet dosage form.

    PubMed

    Jain, P S; Patel, M K; Gorle, A P; Chaudhari, A J; Surana, S J

    2012-09-01

    A simple, specific, accurate and precise stability-indicating reversed-phase high-performance liquid chromatographic method was developed for simultaneous estimation of olmesartan medoxomile (OLME), amlodipine besylate (AMLO) and hydrochlorothiazide (HCTZ) in tablet dosage form. The method was developed using an RP C18 base deactivated silica column (250 × 4.6 mm, 5 µm) with a mobile phase consisting of triethylamine (pH 3.0) adjusted with orthophosphoric acid (A) and acetonitrile (B), with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 mL/min. Ultraviolet detection was used at 236 nm. The retention times for OLME, AMLO and HCTZ were found to be 6.72, 4.28 and 2.30, respectively. The proposed method was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curves of OLME, AMLO and HCTZ were linear over the range of 50-150, 12.5-37.5 and 31-93 µg/mL, respectively. The method was found to be sensitive. The limits of detection of OLME, AMLO and HCTZ were determined 0.19, 0.16 and 0.22 µg/mL and limits of quantification of OLME, AMLO and HCTZ were determined 0.57, 0.49 and 0.66, respectively. Forced degradation study was performed according to International Conference on Harmonization guidelines.

  6. New Stability-Indicating RP-HPLC Method for Determination of Diclofenac Potassium and Metaxalone from their Combined Dosage Form

    PubMed Central

    Panda, Sagar Suman; Patanaik, Debasis; Ravi Kumar, Bera V. V.

    2012-01-01

    A simple, precise and accurate isocratic RP-HPLC stability-indicating assay method has been developed to determine diclofenac potassium and metaxalone in their combined dosage forms. Isocratic separation was achieved on a Hibar-C18, Lichrosphere-100® (250 mm × 4.6 mm i.d., particle size 5 μm) column at room temperature in isocratic mode, the mobile phase consists of methanol: water (80:20, v/v) at a flow rate of 1.0 ml/min, the injection volume was 20 μl and UV detection was carried out at 280nm. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, precision, accuracy, robustness and system suitability. The method was linear in the drug concentration range of 2.5–30 μg/ml and 20–240 μg/ml for diclofenac potassium and metaxalone, respectively. The precision (RSD) of six samples was 0.83 and 0.93% for repeatability, and the intermediate precision (RSD) among six-sample preparation was 1.63 and 0.49% for diclofenac potassium and metaxalone, respectively. The mean recoveries were between 100.99–102.58% and 99.97–100.01% for diclofenac potassium and metaxalone, respectively. The proposed method can be used successfully for routine analysis of the drug in bulk and combined pharmaceutical dosage forms. PMID:22396909

  7. Development and validation of a novel stability-indicating HPLC method for the quantitative determination of eleven related substances in ezetimibe drug substance and drug product.

    PubMed

    Luo, Zhiqiang; Deng, Zhongqing; Liu, Yang; Wang, Guopeng; Yang, Wenning; Hou, Chengbo; Tang, Minming; Yang, Ruirui; Zhou, Huaming

    2015-07-01

    Ezetimibe is a novel lipid-lowering agent that inhibits intestinal absorption of dietary and biliary cholesterol. In the present work, a simple, sensitive and reproducible gradient reverse phase high performance liquid chromatographic (RP-HPLC) method for separation and determination of the related substances of ezetimibe was developed and validated. Eleven potential process-related impurities (starting materials, (3S,4S,3'S)-isomer, degradants and byproducts) were identified in the crude samples. Tentative structures for all the impurities were assigned primarily based on comparison of their retention time and mass spectrometric data with that of available standards and references. This method can be applied to routine analysis in quality control of both bulk drugs and commercial tablets. Separation of all these compounds was performed on a Phenomenex Luna Phenyl-Hexyl (100mm×4.6mm, 5μm) analytical column. The mobile phase-A consists of acetonitrile-water (pH adjusted to 4.0 with phosphoric acid)-methanol at 15:75:10 (v/v/v), and mobile phase-B contains acetonitrile. The eluted compounds were monitored at 210nm. Ezetimibe was subjected to hydrolytic, acid, base, oxidative, photolytic and thermal stress conditions as per ICH serves to generate degradation products that can be used as a worst case to assess the analytical method performance. The drug showed extensive degradation in thermal, acid, oxidative, base and hydrolytic stress conditions, while it was stable to photolytic degradation conditions. The main degradation product formed under thermal, acid, oxidative, base and hydrolytic stress conditions corresponding to (2R,3R,6S)-N, 6-bis(4-fluorophenyl)-2-(4-hydroxyphenyl)-oxane-3-carboxamide (Ezetimibe tetrahydropyran impurity) was characterized by LC-MS/MS analysis. The degradation products were well resolved from the main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision and robustness. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. A novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) based bioanalytical method for quantification of ethyl esters of Eicosapentaenoic acid (EPA) and Docosahexaenoic acid (DHA) and its application in pharmacokinetic study.

    PubMed

    Viswanathan, Sekarbabu; Verma, P R P; Ganesan, Muniyandithevar; Manivannan, Jeganathan

    2017-07-15

    Omega-3 fatty acids are clinically useful and the two marine omega-3 fatty acids eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are prevalent in fish and fish oils. Omega-3 fatty acid formulations should undergo a rigorous regulatory step in order to obtain United States Food and Drug Administration (USFDA) approval as prescription drug. In connection with that, despite quantifying EPA and DHA fatty acids, there is a need for quantifying the level of ethyl esters of them in biological samples. In this study, we make use of reverse phase high performance liquid chromatography coupled with mass spectrometry (RP-HPLC-MS)technique for the method development. Here, we have developed a novel multiple reaction monitoring method along with optimized parameters for quantification of EPA and DHA as ethyl esters. Additionally, we attempted to validate the bio-analytical method by conducting the sensitivity, selectivity, precision accuracy batch, carryover test and matrix stability experiments. Furthermore, we also implemented our validated method for evaluation of pharmacokinetics of omega fatty acid ethyl ester formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Development and validation of a discriminative dissolution method for atorvastatin calcium tablets using in vivo data by LC and UV methods.

    PubMed

    Machado, J C; Lange, A D; Todeschini, V; Volpato, N M

    2014-02-01

    A dissolution method to analyze atorvastatin tablets using in vivo data for RP and test pilot (PB) was developed and validated. The appropriate conditions were determined after solubility tests using different media, and sink conditions were established. The conditions used were equipment paddle at 50 rpm and 900 mL of potassium phosphate buffer pH 6.0 as dissolution medium. In vivo release profiles were obtained from the bioequivalence study of RP and the generic candidate PB. The fraction of dose absorbed was calculated using the Loo-Riegelman method. It was necessary to use a scale factor of time similar to 6.0, to associate the values of absorbed fraction and dissolved fraction, obtaining an in vivo-in vitro correlation level A. The dissolution method to quantify the amount of drug dissolved was validated using high-performance liquid chromatography and ultraviolet spectrophotometry, and validated according to the USP protocol. The discriminative power of dissolution conditions was assessed using two different pilot batches of atorvastatin tablets (PA and PB) and RP. The dissolution test was validated and may be used as a discriminating method in quality control and in the development of the new formulations.

  10. RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines

    NASA Technical Reports Server (NTRS)

    VanNoord, J. L.; Stiegemeier, B. R.

    2010-01-01

    A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.

  11. 75 FR 65366 - Recovery Policy RP9524.2, Landslides and Slope Stability Related to Public Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-22

    ...] Recovery Policy RP9524.2, Landslides and Slope Stability Related to Public Facilities AGENCY: Federal... the final Recovery Policy RP9524.2, Landslides and Slope Stability Related to Public Facilities, which... facilities threatened by landslides or slope failures; as well as the eligibility of permanent repairs to...

  12. Progress in a selective method for the determination of the acetaldehyde-derived DNA adducts by using HILIC-ESI-MS/MS.

    PubMed

    Murakami, Hiroya; Horiba, Ruri; Iwata, Tomoko; Miki, Yuta; Uno, Bunji; Sakai, Tadao; Kaneko, Kazuhiro; Ishihama, Yasushi; Teshima, Norio; Esaka, Yukihiro

    2018-01-15

    Acetaldehyde (AA), which is present in tobacco smoke, automobile exhaust gases and alcohol beverage, is a mutagen and carcinogen. AA reacts with 2'-deoxyguanosine (dG) in DNA to form N 2 -ethyl-dG (EtdG) and cyclic, 1, N 2 -propano-dG (CPrdG), which are considered to have a critical role in carcinogenesis induced by AA. In this study, we have developed a highly sensitive method for the quantitation of the two AA-derived DNA adducts by using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) in which hydrophilic interaction chromatography (HILIC) employing mobile phases of high organic solvent concentration was selected to improve the ionization efficiency in the ESI process. Fourteen times and 11 times larger peak areas for EtdG and CPrdG, respectively, in HILIC-ESI-MS/MS were obtained compared with those in reversed phase (RP)-LC-ESI-MS/MS. Furthermore, 6.9 times (for EtdG) and 2.4 times (for CPrdG) larger peak areas were also obtained as additional enhancement by varying additive compounds in the HILIC mobile phases from ammonium acetate to ammonium bicarbonate. In total, the enhancements in detected MS signal intensities by exchanging from the RP-LC system to the HILIC system are 97 times for EtdG and 26 times for CPrdG, respectively. Three commercially available HILIC columns with different polar functional groups were examined and sufficient separation between normal 2'-deoxynucleosides and the AA-derived DNA adducts was achieved by a carbamoyl-bonded HILIC column. Finally, we applied the established method to quantify EtdG and CPrdG in the damaged calf thymus DNA. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Facile construction of macroporous hybrid monoliths via thiol-methacrylate Michael addition click reaction for capillary liquid chromatography.

    PubMed

    Lin, Hui; Ou, Junjie; Liu, Zhongshan; Wang, Hongwei; Dong, Jing; Zou, Hanfa

    2015-01-30

    A facile approach based on thiol-methacrylate Michael addition click reaction was developed for construction of porous hybrid monolithic materials. Three hybrid monoliths were prepared via thiol-methacrylate click polymerization by using methacrylate-polyhedral oligomeric silsesquioxane (POSS) (cage mixture, n=8, 10, 12, POSS-MA) and three multi-thiol crosslinkers, 1,6-hexanedithiol (HDT), trimethylolpropane tris(3-mercaptopropionate) (TPTM) and pentaerythritol tetrakis(3-mercaptopropionate) (PTM), respectively, in the presence of porogenic solvents (n-propanol and PEG 200) and a catalyst (dimethylphenylphosphine, DMPP). The obtained monoliths possessed high thermal and chemical stabilities. Besides, they all exhibited high column efficiencies and excellent separation abilities in capillary liquid chromatography (cLC). The highest column efficiency could reach ca. 195,000N/m for butylbenzene on the monolith prepared with POSS-MA and TPTM (monolith POSS-TPTM) in reversed-phase (RP) mode at 0.64mm/s. Good chromatographic performance were all achieved in the separations of polycyclic aromatic hydrocarbons (PAHs), phenols, anilines, EPA 610 as well as bovine serum albumin (BSA) digest. The high column efficiencies in the range of 51,400-117,000N/m (achieved on the monolith POSS-PTM in RP mode) convincingly demonstrated the high separation abilities of these thiol-methacrylate based hybrid monoliths. All the results demonstrated the feasibility of the phosphines catalyzed thiol-methacrylate Michael addition click reaction in fabrication of monolithic columns with high efficiency for cLC applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Effects of large volume injection of aliphatic alcohols as sample diluents on the retention of low hydrophobic solutes in reversed-phase liquid chromatography.

    PubMed

    David, Victor; Galaon, Toma; Aboul-Enein, Hassan Y

    2014-01-03

    Recent studies showed that injection of large volume of hydrophobic solvents used as sample diluents could be applied in reversed-phase liquid chromatography (RP-LC). This study reports a systematic research focused on the influence of a series of aliphatic alcohols (from methanol to 1-octanol) on the retention process in RP-LC, when large volumes of sample are injected on the column. Several model analytes with low hydrophobic character were studied by RP-LC process, for mobile phases containing methanol or acetonitrile as organic modifiers in different proportions with aqueous component. It was found that starting with 1-butanol, the aliphatic alcohols can be used as sample solvents and they can be injected in high volumes, but they may influence the retention factor and peak shape of the dissolved solutes. The dependence of the retention factor of the studied analytes on the injection volume of these alcohols is linear, with a decrease of its value as the sample volume is increased. The retention process in case of injecting up to 200μL of upper alcohols is dependent also on the content of the organic modifier (methanol or acetonitrile) in mobile phase. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Development and validation of a stability-indicating LC method for the assay of lodenafil carbonate in tablets.

    PubMed

    Codevilla, Cristiane Franco; Lemos, Alice Machado; Delgado, Leila Schreiner; Rolim, Clarice Madalena Bueno; Adams, Andréa Inês Horn; Bergold, Ana Maria

    2011-08-01

    A stability-indicating liquid chromatographic method has been developed for the quantitative determination of lodenafil carbonate in tablets. The method employs a Synergi Fusion C18 column (250 × 4.6 mm, i.d., 4 μm particle size), with mobile phase consisting of a mixture of methanol-acetic acid 0.1% pH 4.0 (65:35, v/v) and UV detection at 290 nm, using a photodiode array detector. A linear response (r = 0.9999) was observed in the range of 10-80 μg/mL. The method showed good recoveries (average 100.3%) and also intra and inter-day precision (RSD < 2.0%). Validation parameters as specificity and robustness were also determined. Specificity analysis showed that no impurities or degradation products were co-eluting with the lodenafil carbonate peak. The method was found to be stability-indicating and due to its simplicity and accuracy can be applied for routine quality control analysis of lodenafil carbonate in tablets.

  16. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source.

    PubMed

    Yu, Kate; Di, Li; Kerns, Edward; Li, Susan Q; Alden, Peter; Plumb, Robert S

    2007-01-01

    We report in this paper an ultra-performance liquid chromatography/tandem mass spectrometric (UPLC(R)/MS/MS) method utilizing an ESI-APCI multimode ionization source to quantify structurally diverse analytes. Eight commercial drugs were used as test compounds. Each LC injection was completed in 1 min using a UPLC system coupled with MS/MS multiple reaction monitoring (MRM) detection. Results from three separate sets of experiments are reported. In the first set of experiments, the eight test compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes (ESI+, ESI-, APCI-, and APCI+) during an LC run. Approximately 8-10 data points were collected across each LC peak. This was insufficient for a quantitative analysis. In the second set of experiments, four compounds were analyzed as a single mixture. The mass spectrometer was switching rapidly among four ionization modes during an LC run. Approximately 15 data points were obtained for each LC peak. Quantification results were obtained with a limit of detection (LOD) as low as 0.01 ng/mL. For the third set of experiments, the eight test compounds were analyzed as a batch. During each LC injection, a single compound was analyzed. The mass spectrometer was detecting at a particular ionization mode during each LC injection. More than 20 data points were obtained for each LC peak. Quantification results were also obtained. This single-compound analytical method was applied to a microsomal stability test. Compared with a typical HPLC method currently used for the microsomal stability test, the injection-to-injection cycle time was reduced to 1.5 min (UPLC method) from 3.5 min (HPLC method). The microsome stability results were comparable with those obtained by traditional HPLC/MS/MS.

  17. Development and validation of a rapid reverse-phase HPLC method for the determination of methotrexate from nanostructured liquid crystalline systems.

    PubMed

    Zuben, E S Von; Oliveira, A G; Chorilli, M; Scarpa, M V

    2018-03-05

    A reversed-phase liquid chromatography (RP-LC) method was successfully developed and validated for the determination of methotrexate in nanostructured liquid crystalline systems composed by polyether functional siloxane and silicone polyether copolymer. The LC method was performed on RP C18-ODS column, Agilent Zorbax® (4.6 x 250 mm, 5 μm), maintained at room temperature, with a mobile phase constituted by a mixture of 50 mM ammonium acetate buffer (pH 6.0) and methanol (77:23,v/v) with a flow rate of 1.0 mL/min, using ultraviolet detection at 313 nm. The parameters used in the validation process were linearity, specificity, intra and inter-day precision, accuracy, robustness. The quantitation and detection limits yielded good results. The calibration plot assumed linear behavior from 5.0-150.0 μg. mL-1 (r2 = 0.9999). The methotrexate was subjected to oxidation, acid, base and neutral degradation, photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of methotrexate. The nanostructured liquid crystalline systems did not interfere with the analysis and the recovery was quantitative. The intra and inter-day assay relative standard deviation were less than 0.20 %. The method developed proved to be simple, sensitive, accurate, precise, reproducible and therefore adequate for routine analysis of methotrexate in nanostructured liquid crystalline systems.

  18. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF

    PubMed Central

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D.; Yanjanin, Nicole M.; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S.; Jiang, Xuntian

    2014-01-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and “dilute and shoot” procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. PMID:24868096

  19. Development and validation of sensitive LC-MS/MS assays for quantification of HP-β-CD in human plasma and CSF.

    PubMed

    Jiang, Hui; Sidhu, Rohini; Fujiwara, Hideji; De Meulder, Marc; de Vries, Ronald; Gong, Yong; Kao, Mark; Porter, Forbes D; Yanjanin, Nicole M; Carillo-Carasco, Nuria; Xu, Xin; Ottinger, Elizabeth; Woolery, Myra; Ory, Daniel S; Jiang, Xuntian

    2014-07-01

    2-Hydroxypropyl-β-cyclodextrin (HP-β-CD), a widely used excipient for drug formulation, has emerged as an investigational new drug for the treatment of Niemann-Pick type C1 (NPC1) disease, a neurodegenerative cholesterol storage disorder. Development of a sensitive quantitative LC-MS/MS assay to monitor the pharmacokinetics (PKs) of HP-β-CD required for clinical trials has been challenging owing to the dispersity of the HP-β-CD. To support a phase 1 clinical trial for ICV delivery of HP-β-CD in NPC1 patients, novel methods for quantification of HP-β-CD in human plasma and cerebrospinal fluid (CSF) using LC-MS/MS were developed and validated: a 2D-LC-in-source fragmentation-MS/MS (2D-LC-IF-MS/MS) assay and a reversed phase ultra performance LC-MS/MS (RP-UPLC-MS/MS) assay. In both assays, protein precipitation and "dilute and shoot" procedures were used to process plasma and CSF, respectively. The assays were fully validated and in close agreement, and allowed determination of PK parameters for HP-β-CD. The LC-MS/MS methods are ∼100-fold more sensitive than the current HPLC assay, and were successfully employed to analyze HP-β-CD in human plasma and CSF samples to support the phase 1 clinical trial of HP-β-CD in NPC1 patients. Copyright © 2014 by the American Society for Biochemistry and Molecular Biology, Inc.

  20. Bioanalytical LC-MS/MS method development and validation of novel antidiabetic candidate S007-1261 in rat plasma and its application to pharmacokinetic and oral bioavailability studies.

    PubMed

    Misra, A; Kushwaha, H N; Gautam, N; Singh, B; Verma, P C; Pratap, R; Singh, S K

    2014-08-01

    A sensitive and selective LC-MS/MS method has been developed and validated for CDRI antidiabetic candidate S007-1261 in rat plasma using 16-dehydropregnenolone as an internal standard. The API 4000 triple quadrupole LC-MS/MS system was operated under multiple reaction monitoring mode using electrospray ionization technique in positive mode. The sample processing method involves 2-step liquid-liquid extraction using n-hexane as an extracting solvent. The analyte was chromatographed on RP 18, waters column (3.5 µm, 2.1 mm i.d. × 30 mm) with guard using acetonitrile and ammonium acetate buffer (pH 5.0, 10 mM) in 90:10 (v/v) composition at a flow rate of 0.40 mL min(-1). The chromatographic run time was 5.30 min. Calibration curve shows linearity over concentration range 1.56-200 ng mL(-1). The lower limit of detection was 0.39 ng mL(-1) and lower limit of quantitation was 1.56 ng mL(-1). The inter- and intra-day accuracy and precision were found to be within the assay variability limits as per US FDA guidelines. The absolute recovery of S007-1261 was found to be >90%. S007-1261 does not show any stability problems as it was stable at room temperature for 8 h. S007-1261 was also stable up to 3 freeze-thaw cycles and can be stored up to 30 days at -60 °C. The assay was successfully applied to both oral (40 mg kg(-1)) and intravenous (10 mg kg(-1)) pharmacokinetic studies in male Sprague-Dawley rats. The oral bioavailability of S007-1261 was found to be 33.61%. © Georg Thieme Verlag KG Stuttgart · New York.

  1. Development of high-throughput multi-residue method for non-steroidal anti-inflammatory drugs monitoring in swine muscle by LC-MS/MS.

    PubMed

    Castilhos, Tamara S; Barreto, Fabiano; Meneghini, Leonardo; Bergold, Ana Maria

    2016-07-01

    A reliable and simple method for the detection and quantification of residues of 14 non-steroidal anti-inflammatory drugs and a metamizole metabolite in swine muscle was developed using liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS). The samples were extracted with acetonitrile (ACN) in solid-liquid extraction followed by a low-temperature partitioning (LLE-LTP) process at -20 ± 2°C. After evaporation to dryness, the residue was reconstituted with hexane and a mixture of water:acetonitrile (1:1). LC separation was achieved on a reversed-phase (RP18) column with gradient elution using water (phase A) and ACN (phase B) both containing 1 mmol l(-)(1) ammonium acetate (NH4COO) with 0.025% acetic acid. Analysis was carried out on a triple-quadrupole tandem mass spectrometer (LC-MS/MS) in multiple reaction monitoring mode using an electrospray interface in negative and positive mode in a single run. Method validation was performed according to the criteria of Commission Decision No. 2002/657/EC. The matrix effect and linearity were evaluated. Decision limit (CCα), detection capability (CCβ), accuracy and repeatability of the method are also reported. The proposed method proved to be simple, easy and adequate for high-throughput analysis and was applied to routine analysis by the Brazilian Ministry of Agriculture, Livestock and Food Supply.

  2. Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms.

    PubMed

    Krishnaiah, Ch; Reddy, A Raghupathi; Kumar, Ramesh; Mukkanti, K

    2010-11-02

    A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of purity of Valsartan drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. The method was developed using Waters Aquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 225 nm, the run time was within 9.5 min, which Valsartan and its seven impurities were well separated. Valsartan was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Valsartan was found to degrade significantly in acid and oxidative stress conditions and stable in base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of Valsartan in pharmaceutical dosage forms.

  3. NOVEL CONTINUOUS PH/SALT GRADIENT AND PEPTIDE SCORE FOR STRONG CATION EXCHANGE CHROMATOGRAPHY IN 2D-NANO-LC/MSMS PEPTIDE IDENTIFICATION FOR PROTEOMICS

    EPA Science Inventory

    Tryptic digests of human serum albumin (HSA) and human lung epithelial cell lysates were used as test samples in a novel proteomics study. Peptides were separated and analyzed using 2D-nano-LC/MSMS with strong cation exchange (SCX) and reverse phase (RP) chromatography and contin...

  4. LC-MS and MS/MS in the analysis of recombinant proteins

    NASA Astrophysics Data System (ADS)

    Coulot, M.; Domon, B.; Grossenbacher, H.; Guenat, C.; Maerki, W.; Müller, D. R.; Richter, W. J.

    1993-03-01

    Applicability and performance of electrospray ionization mass spectrometry (ESIMS) is demonstrated for protein analysis. ESIMS is applied in conjunction with on-line HPLC (LC-ESlMS) and direct tandem mass spectrometry (positive and negative ion mode ESlMS/MS) to the structural characterization of a recombinant protein (r-hirudin variant 1) and a congener phosphorylated at threonine 45 (RP-1).

  5. Multiple, simultaneous, independent gradients for a versatile multidimensional liquid chromatography. Part II: Application 1 - Large increases in isoform resolution of human transferrin by use of dual simultaneous independent gradients of pH & acetonitrile on a mixed bed (anion exchange plus reversed phase) stationary phase.

    PubMed

    Tsonev, Latchezar I; Hirsh, Allen G

    2016-10-14

    We have previously described a liquid chromatographic (LC) method for uncoupling controlled, wide range pH gradients and simultaneous controlled gradients of a non-buffering solute on ion exchange resins (Hirsh and Tsonev, 2012) [1]. Here we report the application of this two dimensional LC technique to the problem of resolving Human Transferrin (HT) isoforms. This important iron transporting protein should theoretically occur in several thousand glycoforms, but only about a dozen have been reported. Using dual simultaneous independent gradients (DSIGs) of acetonitrile (ACN) and pH on a mixed bed stationary phase (SP) consisting of a mixture of an anion exchange resin and a reversed phase (RP) resin we partially resolve about 60 isoforms. These are likely to be partially refolded glycoforms generated by interaction of HT with the highly hydrophobic RP SP, as well as distinct folded glycoforms. Thus this study should have interesting implications for both glycoform separation and the study of protein folding. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Simultaneous determination of carotenoids, tocopherols, and gamma-oryzanol in crude rice bran oil by liquid chromatography coupled to diode array and mass spectrometric detection employing silica C30 stationary phases.

    PubMed

    Stöggl, Wolfgang; Huck, Christain; Wongyai, Surapote; Scherz, Heimo; Bonn, Günther

    2005-09-01

    Crude rice bran oil contains tocopherols (vitamin E), carotenoids (vitamin A), and phytosterols, which possess antioxidant activities and show promising effects as preventive and therapeutic agents. The aim of this work was to establish methods and to compare C18 and C30 silica stationary phases in order to separate and detect tocopherols, carotenoids, and gamma-oryzanol in one single run. Comparing RP-LC on silica C18 and C30, higher resolution between all target compounds was obtained using the C30 stationary phase. Methanol was used as eluent and the elution strength was increased by the addition of tert-butyl methyl ether for highly hydrophobic analytes such as gamma-oryzanol. Detection was accomplished by diode array detection from 200 to 500 nm. Absorbance maxima were found at 295 nm for tocopherols, 324 nm for gammaoryzanol, and 450 nm for carotenoids. Furthermore, compounds were characterized and identified on the basis of their UV-spectra. Both RP systems were coupled to MS (LC-MS) by using an atmospheric pressure chemical ionization interface.

  7. Separation and characterization of chemical constituents in Ginkgo biloba extract by off-line hydrophilic interaction×reversed-phase two-dimensional liquid chromatography coupled with quadrupole-time of flight mass spectrometry.

    PubMed

    Ji, Shuai; He, Dan-Dan; Wang, Tian-Yun; Han, Jie; Li, Zheng; Du, Yan; Zou, Jia-Hui; Guo, Meng-Zhe; Tang, Dao-Quan

    2017-11-30

    Ginkgo biloba extract (GBE), derived from the leaves of Ginkgo biloba L., is one of the most widely used traditional Chinese medicines worldwide. Due to high structural diversity and low abundance of chemical constituents in GBE, conventional reversed-phase liquid chromatography has limited power to meet the needs of its quality control. In this study, an off-line hydrophilic interaction×reversed-phase two-dimensional liquid chromatography (HILIC×RP 2D-LC) system coupled with diode array detection (DAD) and quadrupole time-of-flight mass spectrometry (qTOF-MS) was established to comprehensively analyze the chemical constituents of GBE. After optimizing the chromatographic columns and mobile phase of 2D-LC, a Waters XBridge Amide column using acetonitrile/water/formic acid as the mobile phase was selected as the first dimension to fractionate GBE, and the obtained fractions were further separated on an Agilent Zorbax XDB-C18 column with methanol/water/formic acid as the mobile phase. As a result, a total of 125 compounds were detected in GBE. The orthogonality of the 2D-LC system was 69.5%, and the practical peak capacity was 3864 and 2994, respectively, calculated by two different methods. The structures of 104 compounds were tentatively characterized by qTOF-MS analysis, and 21 of them were further confirmed by comparing with reference standards. This established HILIC×RP 2D-LC-qTOF/MS system can greatly improve the separation and characterization of natural products in GBE or other complicated herbal extracts. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Acid/Salt/pH Gradient Improved Resolution and Sensitivity in Proteomics Study Using 2D SCX-RP LC-MS.

    PubMed

    Zhu, Ming-Zhi; Li, Na; Wang, Yi-Tong; Liu, Ning; Guo, Ming-Quan; Sun, Bao-Qing; Zhou, Hua; Liu, Liang; Wu, Jian-Lin

    2017-09-01

    The usage of strong cation exchange (SCX) chromatography in proteomics is limited by its poor resolution and nonspecific hydrophobic interactions with peptides, which lead to peptide overlap across fractions and change of peptide retention, respectively. The application of high concentration of salt (up to 1000 mM) in SCX also restricted its use in online 2D SCX-RP LC. In the present research, we first exploited the chromatographic ability of online 2D SCX-RP LC by combination of acid, salt, and pH gradient, three relatively independent modes of eluting peptides from SCX column. 50% ACN was added to elution buffer for eliminating hydrophobic interactions between SCX matrix and peptides, and the concentration of volatile salt was reduced to 50 mM. Acid/salt/pH gradient showed superior resolution and sensitivity as well as uniform distribution across fractions, consequently leading to significant improvements in peptide and protein identification. 112 191 unique peptides and 7373 proteins were identified by acid/salt/pH fractionation, while 69 870 unique peptides and 4536 proteins were identified by salt elution, that is, 62.5 and 60.6% more proteins and unique peptides, respectively, identified by the former. Fraction overlap was also significantly minimized by acid/salt/pH approach. Furthermore, acid/salt/pH elution showed more identification for acidic peptides and hydrophilic peptides.

  9. Automation of nanoflow liquid chromatography-tandem mass spectrometry for proteome analysis by using a strong cation exchange trap column.

    PubMed

    Jiang, Xiaogang; Feng, Shun; Tian, Ruijun; Han, Guanghui; Jiang, Xinning; Ye, Mingliang; Zou, Hanfa

    2007-02-01

    An approach was developed to automate sample introduction for nanoflow LC-MS/MS (microLC-MS/MS) analysis using a strong cation exchange (SCX) trap column. The system consisted of a 100 microm id x 2 cm SCX trap column and a 75 microm id x 12 cm C18 RP analytical column. During the sample loading step, the flow passing through the SCX trap column was directed to waste for loading a large volume of sample at high flow rate. Then the peptides bound on the SCX trap column were eluted onto the RP analytical column by a high salt buffer followed by RP chromatographic separation of the peptides at nanoliter flow rate. It was observed that higher performance of separation could be achieved with the system using SCX trap column than with the system using C18 trap column. The high proteomic coverage using this approach was demonstrated in the analysis of tryptic digest of BSA and yeast cell lysate. In addition, this system was also applied to two-dimensional separation of tryptic digest of human hepatocellular carcinoma cell line SMMC-7721 for large scale proteome analysis. This system was fully automated and required minimum changes on current microLC-MS/MS system. This system represented a promising platform for routine proteome analysis.

  10. Ultra-High Performance Liquid Chromatography (UHPLC) Method for the Determination of Limonene in Sweet Orange (Citrus sinensis) Oil: Implications for Limonene Stability.

    PubMed

    Bernart, Matthew W

    2015-01-01

    The citrus-derived bioactive monoterpene limonene is an important industrial commodity and fragrance constituent. An RP isocratic elution C18 ultra-HPLC (UHPLC) method using a superficially porous stationary phase and photodiode array (PDA) detector has been developed for determining the limonene content of sweet orange (Citrus sinensis) oil. The method is fast with a cycle time of 1.2 min, linear, precise, accurate, specific, and stability indicating, and it satisfies U.S. Pharmacopeia suitability parameters. The method may be useful in its present form for limonene processing, or modified for research on more polar compounds of the terpenome. A forced-degradation experiment showed that limonene is degraded by heat in hydro-ethanolic solution. PDA detection facilitates classification of minor components of the essential oil, including β-myrcene.

  11. Stability indicating simplified HPLC method for simultaneous analysis of resveratrol and quercetin in nanoparticles and human plasma.

    PubMed

    Kumar, Sandeep; Lather, Viney; Pandita, Deepti

    2016-04-15

    Resveratrol and quercetin are well-known polyphenolic compounds present in common foods, which have demonstrated enormous potential in the treatment of a wide variety of diseases. Owing to their exciting synergistic potential and combination delivery applications, we developed a simple and rapid RP-HPLC method based on isosbestic point detection. The separation was carried out on phenomenex Synergi 4μ Hydro-RP 80A column using methanol: acetonitrile (ACN): 0.1% phosphoric acid (60:10:30) as mobile phase. The method was able to quantify nanograms of analytes simultaneously on a single wavelength (269 nm), making it highly sensitive, rapid as well as economical. Additionally, forced degradation studies of resveratrol and quercetin were established and the method's applicability was evaluated on PLGA nanoparticles and human plasma. The analytes peaks were found to be well resolved in the presence of degradation products and excipients. The simplicity of the developed method potentializes its suitability for routine in vitro and in vivo analysis of resveratrol and quercetin. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Quantitation of Melatonin and N-acetylserotonin in Human Plasma by Nanoflow LC-MS/MS and Electrospray LC-MS/MS

    PubMed Central

    Carter, Melissa D.; Calcutt, M. Wade; Malow, Beth A.; Rose, Kristie L.; Hachey, David L.

    2012-01-01

    Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability, and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1×100 mm, 3.5 μm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 μm, 125 Å). Quantitation was done using the SRM transitions m/z 233→174 and m/z 219→160 for MEL and NAS, respectively. The analytical response ratio vs. concentration curves were linear for MEL (nanoflow LC: 11.7–1165 pg/mL, LC: 1165–116500 pg/mL) and for NAS (nanoflow LC: 11.0–1095 pg/mL). PMID:22431453

  13. Development and validation of a stability-indicating capillary zone electrophoretic method for the assessment of entecavir and its correlation with liquid chromatographic methods.

    PubMed

    Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim

    2011-01-01

    A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).

  14. Simultaneous detection and quantification of amphetamines, diazepam and its metabolites, cocaine and its metabolites, and opiates in hair by LC-ESI-MS-MS using a single extraction method.

    PubMed

    Miller, Eleanor I; Wylie, Fiona M; Oliver, John S

    2008-09-01

    A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous identification and quantification of amphetamines, diazepam and its metabolites, cocaine and its metabolites, and opiates from hair using a single extraction method. As part of the method development, Gemini C18, Synergi Hydro RP, and Zorbax Stablebond-Phenyl LC columns were tested with three different mobile phases. Analyte recovery and limit of detection were evaluated for two different solid-phase extraction methods that used Bond Elut Certify and Clean Screen cartridges. Phosphate buffer (pH 5.0) was chosen as the optimum hair incubation medium because of the high stability of cocaine and 6-monoacetylmorphine using this method and faster sample preparation. The optimized method was fully validated. Linearity was established over the concentration range 0.2-10 ng/mg hair, and the correlation coefficients were all greater than 0.99. Total extraction recoveries were greater than 76%, detection limits were between 0.02 and 0.09 ng/mg, and the intra- and interday imprecisions were generally less than 20% in spiked hair. The intra- and interbatch imprecision of the method for a pooled authentic hair sample ranged from 1.4 to 23.4% relative standard deviation (RSD) and 8.3 to 25.4% RSD, respectively, for representative analytes from the different drug groups. The percent matrix effect ranged from 63.5 to 135.6%, with most analytes demonstrating ion suppression. Sixteen postmortem samples collected from suspected drug-related deaths were analyzed for the 17 drugs of abuse and metabolites included in the method. The method was sufficiently sensitive and specific for the analysis of drugs and metabolites in postmortem hair samples. There is scope for the inclusion of other target drugs and metabolites in the method.

  15. Development of a fast LC-MS/MS assay for the determination of deferiprone in human plasma and application to pharmacokinetics.

    PubMed

    Song, Ta-Shu; Hsieh, Yow-Wen; Peng, Ching-Tien; Liu, Cheng-Hsiung; Chen, Tai-Lin; Hour, Mann-Jen

    2012-12-01

    A fast and accurate liquid chromatography/tandem mass spectrometric (LC-MS/MS) assay was first developed and validated for the determination of deferiprone in human plasma. The analytes were extracted with acetonitrile from only 50 μL aliquots of human plasma to achieve the protein precipitation. After extraction, chromatographic separation of analytes in human plasma was performed using a Synergi Fusion-RP 80A column at 30 °C. The mobile phase consisted of methanol and 0.2% formic acid containing 0.2 mM EDTA (60:40, v/v). The flow rate of the mobile phase was 0.8 mL/min. The total run time for each sample analysis was 4 min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the precursor-to-parent ion transitions m/z 140.1 → 53.1 for deferiprone and m/z 143.1 → 98.1 for internal standard. A linear range was established from 0.1 to 20 µg/mL. The limit of detection was determined as 0.05 µg/mL. The validated method was estimated for linearity, recovery, stability, precision and accuracy. Intraday and interday precisions were 4.3-5.5 and 4.6-7.3%, respectively. The recovery of deferiprone was in the range of 80.1-86.8%. The method was successfully applied to a pharmacokinetic study of deferiprone in six thalassemia patients. Copyright © 2012 John Wiley & Sons, Ltd.

  16. An LC-MS/MS method for rapid and sensitive high-throughput simultaneous determination of various protein kinase inhibitors in human plasma.

    PubMed

    Abdelhameed, Ali S; Attwa, Mohamed W; Kadi, Adnan A

    2017-02-01

    A reliable, high-throughput and sensitive LC-MS/MS procedure was developed and validated for the determination of five tyrosine kinase inhibitors in human plasma. Following their extraction from human plasma, samples were eluted on a RP Luna®-PFP 100 Å column using a mobile phase system composed of acetonitrile and 0.01 m ammonium formate in water (pH ~4.1) with a ratio of (50:50, v/v) flowing at 0.3 mL min -1 . The mass spectrometer was operating with electrospray ionization in the positive ion multiple reaction monitoring mode. The proposed methodology resulted in linear calibration plots with correlation coefficients values of r 2  = 0.9995-0.9999 from concentration ranges of 2.5-100 ng mL -1 for imatinib, 5.0-100 ng mL -1 for sorafenib, tofacitinib and afatinib, and 1.0-100 ng mL -1 for cabozantinib. The procedure was validated in terms of its specificity, limit of detection (0.32-1.71 ng mL -1 ), lower limit of quantification (0.97-5.07 ng mL -1 ), intra- and inter assay accuracy (-3.83 to +2.40%) and precision (<3.37%), matrix effect and recovery and stability. Our results demonstrated that the proposed method is highly reliable for routine quantification of the investigated tyrosine kinase inhibitors in human plasma and can be efficiently applied in the rapid and sensitive analysis of their clinical samples. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography.

    PubMed

    Vanhoenacker, Gerd; Dos Santos Pereira, Alberto; Kotsuka, Takashi; Cabooter, Deirdre; Desmet, Gert; Sandra, Pat

    2010-05-07

    The performance of a polymeric stationary phase with reversed-phase properties (ET-RP1) was evaluated for LC separations at elevated temperature. The most significant observation was that the reduced plate height (h) decreased from 3.4 at 25 degrees C (optimal flow 0.5 mL/min) to 2.4 at 150 degrees C (optimal flow 2.5 mL/min) which is comparable to the efficiency obtained with silica-based reversed-phase columns of 4.6mm ID operated at 0.8 mL/min. The phase showed no deterioration after long use at 150 degrees C within the pH range 1-9. Catalytic activity originating from the stationary phase material, e.g. as experienced on zirconium columns operated at elevated temperature, was absent. The performance of ET-RP1 is illustrated with the analysis of some pharmaceutical samples by LC and LC-MS. Operation at elevated temperature also allows to reduce the amount of organic modifier or to replace acetonitrile and methanol by the biodegradable ethanol. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  18. Considerations on comprehensive and off-line supercritical fluid chromatography x reversed-phase liquid chromatography for the analysis of triacylglycerols in fish oil.

    PubMed

    François, Isabelle; Pereira, Alberto dos Santos; Sandra, Pat

    2010-06-01

    The separation of the triacylglycerols in fish oil was performed by comprehensive and off-line supercritical fluid chromatography combined with RP-LC. The first dimension consisted of two serially coupled silver-ion (SI)-loaded columns operated with a supercritical mobile phase (supercritical fluid chromatography, SFC) in both the cases, whereas the second dimension was performed in non-aqueous RP mode (NARP-LC) on a 10-cm monolithic octadecyl silica (ODS) or a 45-cm long ODS column packed with 1.8 microm particles for the comprehensive and off-line separations, respectively. Despite the outstanding performance of the SI-SFC x NARP-LC interface, the high complexity of the sample rendered the online separation far from complete. The off-line approach gave much better separation mainly because of the higher peak capacity of the second-dimension column, but even in this case, the use of MS was mandatory to elucidate the different triacylglycerols in fish oil. The disadvantage of the off-line procedure was the long analysis time.

  19. Control of linear modes in cylindrical resistive magnetohydrodynamics with a resistive wall, plasma rotation, and complex gain

    NASA Astrophysics Data System (ADS)

    Brennan, D. P.; Finn, J. M.

    2014-10-01

    Feedback stabilization of magnetohydrodynamic (MHD) modes in a tokamak is studied in a cylindrical model with a resistive wall, plasma resistivity, viscosity, and toroidal rotation. The control is based on a linear combination of the normal and tangential components of the magnetic field just inside the resistive wall. The feedback includes complex gain, for both the normal and for the tangential components, and it is known that the imaginary part of the feedback for the former is equivalent to plasma rotation [J. M. Finn and L. Chacon, Phys. Plasmas 11, 1866 (2004)]. The work includes (1) analysis with a reduced resistive MHD model for a tokamak with finite β and with stepfunction current density and pressure profiles, and (2) computations with a full compressible visco-resistive MHD model with smooth decreasing profiles of current density and pressure. The equilibria are stable for β = 0 and the marginal stability values βrp,rw < βrp,iw < βip,rw < βip,iw (resistive plasma, resistive wall; resistive plasma, ideal wall; ideal plasma, resistive wall; and ideal plasma, ideal wall) are computed for both models. The main results are: (a) imaginary gain with normal sensors or plasma rotation stabilizes below βrp,iw because rotation suppresses the diffusion of flux from the plasma out through the wall and, more surprisingly, (b) rotation or imaginary gain with normal sensors destabilizes above βrp,iw because it prevents the feedback flux from entering the plasma through the resistive wall to form a virtual wall. A method of using complex gain Gi to optimize in the presence of rotation in this regime with β > βrp,iw is presented. The effect of imaginary gain with tangential sensors is more complicated but essentially destabilizes above and below βrp,iw.

  20. A high-performance liquid chromatography-tandem mass spectrometry method coupled with protein precipitation for determination of granisetron in human plasma and its application to a comparative pharmacokinetic study.

    PubMed

    Zhou, Ying; Jiang, Ji; Hu, Pei; Wang, Hongyun

    2014-12-01

    A rapid, simple and validated method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) has been developed for the determination of granisetron in human plasma. Plasma samples were pre-purified by protein precipitation procedure. The chromatographic separation was achieved with Synergi Polar-RP (75 × 2 mm, 4 µm) column using a mixture of 5 mm pH4.0 ammonium formate and methanol (300:316, v/v) under isocratic conditions at a flow rate of 0.3 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. The analysis time was about 2.5 min. The method was fully validated over the concentration range 0.1-10 ng/mL. The lower limit of quantification was 0.1 ng/mL. Inter- and intra-batch precision was <6.1% and the accuracy was within 95.6-100.0%. The mean extraction recovery was 96.3%. Selectivity, matrix effect and stability were also validated. The method was applied to the comparative pharmacokinetic study of granisetron in Chinese healthy subjects. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Advanced oxygen-hydrocarbon rocket engine study

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.; Ewen, R. L.

    1981-01-01

    This study identifies and evaluates promising LO2/HC rocket engine cycles, produces a consistent and reliable data base for vehicle optimization and design studies, demonstrates the significance of propulsion system improvements, and selects the critical technology areas necessary to realize an improved surface to orbit transportation system. Parametric LO2/HC engine data were generated over a range of thrust levels from 890 to 6672 kN (200K to 1.5M 1bF) and chamber pressures from 6890 to 34500 kN (1000 to 5000 psia). Engine coolants included RP-1, refined RP-1, LCH4, LC3H8, LO2, and LH2. LO2/RP-1 G.G. cycles were found to be not acceptable for advanced engines. The highest performing LO2/RP-1 staged combustion engine cycle utilizes LO2 as the coolant and incorporates an oxidizer rich preburner. The highest performing cycle for LO2/LCH4 and LO2/LC3H8 utilizes fuel cooling and incorporates both fuel and oxidizer rich preburners. LO2/HC engine cycles permitting the use of a third fluid LH2 coolant and an LH2 rich gas generator provide higher performance at significantly lower pump discharge pressures. The LO2/HC dual throat engine, because of its high altitude performance, delivers the highest payload for the vehicle configuration that was investigated.

  2. MS-based monitoring of proteolytic decay of synthetic reporter peptides for quality control of plasma and serum specimens.

    PubMed

    Findeisen, Peter; Thumfart, Jörg Oliver; Costina, Victor; Hofheinz, Ralf; Neumaier, Michael

    2013-09-01

    To determine the preanalytical quality of serum and plasma by monitoring the time-dependent ex vivo decay of a synthetic reporter peptide (RP) with liquid chromatography/mass spectrometry (LC/MS). Serum and plasma specimens were spiked with the RP and proteolytic fragments were monitored with LC/MS at different preanalytical time points ranging from 2 to 24 hours after blood withdrawal. The concentration of fragments changed in a time-dependent manner, and respective peptide profiles were used to classify specimens according to their preanalytical time span. Classification accuracy was high, with values always above 0.89 for areas under receiver operating characteristic curves. This "proteomics degradation clock" can be used to estimate the preanalytical quality of serum and plasma and might have impact on quality control procedures of biobanking repositories.

  3. The Use of Ammonium Formate as a Mobile-Phase Modifier for LC-MS/MS Analysis of Tryptic Digests

    PubMed Central

    Johnson, Darryl; Boyes, Barry; Orlando, Ron

    2013-01-01

    A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage. PMID:24294112

  4. The use of ammonium formate as a mobile-phase modifier for LC-MS/MS analysis of tryptic digests.

    PubMed

    Johnson, Darryl; Boyes, Barry; Orlando, Ron

    2013-12-01

    A major challenge facing current mass spectrometry (MS)-based proteomics research is the large concentration range displayed in biological systems, which far exceeds the dynamic range of commonly available mass spectrometers. One approach to overcome this limitation is to improve online reversed-phase liquid chromatography (RP-LC) separation methodologies. LC mobile-phase modifiers are used to improve peak shape and increase sample load tolerance. Trifluoroacetic acid (TFA) is a commonly used mobile-phase modifier, as it produces peptide separations that are far superior to other additives. However, TFA leads to signal suppression when incorporated with electrospray ionization (ESI), and thus, other modifiers, such as formic acid (FA), are used for LC-MS applications. FA exhibits significantly less signal suppression, but is not as effective of a modifier as TFA. An alternative mobile-phase modifier is the combination of FA and ammonium formate (AF), which has been shown to improve peptide separations. The ESI-MS compatibility of this modifier has not been investigated, particularly for proteomic applications. This work compares the separation metrics of mobile phases modified with FA and FA/AF and explores the use of FA/AF for the LC-MS analysis of tryptic digests. Standard tryptic-digest peptides were used for comparative analysis of peak capacity and sample load tolerance. The compatibility of FA/AF in proteomic applications was examined with the analysis of soluble proteins from canine prostate carcinoma tissue. Overall, the use of FA/AF improved online RP-LC separations and led to significant increases in peptide identifications with improved protein sequence coverage.

  5. Direct-injection screening for acidic drugs in plasma and neutral drugs in equine urine by differential-gradient LC-LC coupled MS/MS.

    PubMed

    Stanley, Shawn M R; Wee, Wei Khee; Lim, Boon Huat; Foo, Hsiao Ching

    2007-04-01

    Direct-injection LC-LC hybrid tandem MS methods have been developed for undertaking broad-based screening for acidic drugs in protein-precipitated plasma and neutral doping agents in equine urine. In both analyses, analytes present in the matrix were trapped using a HLB extraction column before being refocused and separated on a Chromolith RP-18e monolithic analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Each method has been optimised by the adoption of a mobile phase and gradient that was tailored to enhance ionisation in the MS source while maintaining good chromatographic behaviour for the majority of the target drugs. The analytical column eluent was fed into the heated nebulizer (HN) part of the Duospray interface attached to a 4000 QTRAP mass spectrometer. Information dependent acquisition (IDA) with dynamic background subtraction (DBS) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan signal exceeded the defined criteria. Ninety-one percent of acidic drugs in protein-precipitated plasma and 80% of the neutral compounds in equine urine were detected when spiked at 10 ng/ml.

  6. A rapid screen for four corticosteroids in equine synovial fluid.

    PubMed

    Agrawal, Karan; Ebel, Joseph G; Bischoff, Karyn

    2014-06-01

    Most antidoping method development in the equine industry has been for plasma and urine, though there has been recent interest in the analysis of synovial fluid for evidence of doping by intra-articular corticosteroid injection. Published methods for corticosteroid analysis in synovial fluid are primarily singleplex methods, do not screen for all corticosteroids of interest and are not adequately sensitive. The purpose of this study is to develop a rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS-MS) screening method for the detection of four of the most common intra-articularly administered corticosteroids--betamethasone, methylprednisolone, methylprednisolone acetate and triamcinolone acetonide. Sample preparation consisted of protein precipitation followed by a basified liquid-liquid extraction. LC-MS-MS experiments consisted of a six-min isocratic separation using a Phenomenex Polar-RP stationary phase and a mobile phase consisting of 35% acetonitrile, 5 mM ammonium acetate and 0.1% formic acid in nanopure water. The detection system used was a triple quadrupole mass analyzer with thermospray ionization, and compounds were identified using selective reaction monitoring. The method was validated to the ISO/IEC 17025 standard, and real synovial fluid samples were analyzed to demonstrate the application of the method in an antidoping context. The method was highly selective for the four corticosteroids with limits of detection of 1-3 ng/mL. The extraction efficiency was 50-101%, and the matrix effects were 14-31%. These results indicate that the method is a rapid and sensitive screen for the four corticosteroids in equine synovial fluid, fit for purpose for equine antidoping assays.

  7. Delocalized periodic vibrations in nonlinear LC and LCR electrical chains

    NASA Astrophysics Data System (ADS)

    Chechin, G. M.; Shcherbinin, S. A.

    2015-05-01

    We consider electrical LC- and LCR-chains consisting of N cells. In the LC-chain each cell contains a linear inductor L and a nonlinear capacitor C, while the cell in the LCR-chain include additionally a resistor R and an voltage source. It is assumed that voltage dependence of capacitors represents an even function. Such capacitors have implemented by some experimental groups studying propagation of electrical signals in the lines constructed on MOS and CMOS substrates. In these chains, we study dynamical regimes representing nonlinear normal modes (NNMs) by Rosenberg. We prove that maximum possible number of symmetry-determined NNMs which can be excited in the considered chains is equal to 5. The stability of these modes for different N is studied with the aid of the group-theoretical method [Physical Review E 73 (2006) 36216] which allows to simplify radically the variational systems appearing in the Floquet stability analysis. For NNMs in LC-chain, the scaling of the voltage stability threshold in the thermodynamic limit (N → ∞) is determined. It is shown that the above group theoretical method can be also used for studying stability of NNMs in the LCR-chains.

  8. Hydrophilic Strong Anion Exchange (hSAX) Chromatography for Highly Orthogonal Peptide Separation of Complex Proteomes

    PubMed Central

    2013-01-01

    Due to its compatibility and orthogonality to reversed phase (RP) liquid chromatography (LC) separation, ion exchange chromatography, and mainly strong cation exchange (SCX), has often been the first choice in multidimensional LC experiments in proteomics. Here, we have tested the ability of three strong anion exchanger (SAX) columns differing in their hydrophobicity to fractionate RAW264.7 macrophage cell lysate. IonPac AS24, a strong anion exchange material with ultralow hydrophobicity, demonstrated to be superior to other materials by fractionation and separation of tryptic peptides from both a mixture of 6 proteins as well as mouse cell lysate. The chromatography displayed very high orthogonality and high robustness depending on the hydrophilicity of column chemistry, which we termed hydrophilic strong anion exchange (hSAX). Mass spectrometry analysis of 34 SAX fractions from RAW264.7 macrophage cell lysate digest resulted in an identification of 9469 unique proteins and 126318 distinct peptides in one week of instrument time. Moreover, when compared to an optimized high pH/low pH RP separation approach, the method presented here raised the identification of proteins and peptides by 10 and 28%, respectively. This novel hSAX approach provides robust, reproducible, and highly orthogonal separation of complex protein digest samples for deep coverage proteome analysis. PMID:23294059

  9. Validation and Uncertainty Estimation of an Ecofriendly and Stability-Indicating HPLC Method for Determination of Diltiazem in Pharmaceutical Preparations

    PubMed Central

    Sadeghi, Fahimeh; Navidpour, Latifeh; Bayat, Sima; Afshar, Minoo

    2013-01-01

    A green, simple, and stability-indicating RP-HPLC method was developed for the determination of diltiazem in topical preparations. The separation was based on a C18 analytical column using a mobile phase consisted of ethanol: phosphoric acid solution (pH = 2.5) (35 : 65, v/v). Column temperature was set at 50°C and quantitation was achieved with UV detection at 240 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in diltiazem concentration range of 0.5–50 μg/mL (r 2 = 0.9996). Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.25%–101.66%) ensured the accuracy of the developed method. The degradation products as well as the pharmaceutical excipients were well resolved from the pure drug. The expanded uncertainty (5.63%) of the method was also estimated from method validation data. Accordingly, the proposed validated and sustainable procedure was proved to be suitable for routine analyzing and stability studies of diltiazem in pharmaceutical preparations. PMID:24163778

  10. A validated LC-MS/MS method for the determination of tolterodine and its metabolite in rat plasma and application to pharmacokinetic study.

    PubMed

    Shaik, Rihana Parveen; Puttagunta, Srinivasa Babu; Kothapalli, Chandrasekhar Bannoth; Awen, Bahlul Zayed Sh; Challa, B R

    2013-12-01

    Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was used for simultaneous quantification of tolterodine and its metabolite 5-hydroxy methyl tolterodine in rat plasma. Tolterodine-d6 and 5-hydroxy methyl tolterodine-d14 were used as internal standards (IS). Chromatographic separation was performed on Ascentis Express RP amide (50 mm×4.6 mm, 2.7 μm) column with an isocratic mobile phase composed of 10 mM ammonium acetate and acetonitrile in the ratio of 20:80 (v/v), at a flow-rate of 0.5 mL/min. Tolterodine, tolterodine-d6, 5-hydroxy methyl tolterodine and 5-hydroxy methyl tolterodine-d14 were detected with proton adducts at m / z 326.1→147.1, 332.3→153.1, 342.2→223.1 and 356.2→223.1 in multiple reaction monitoring (MRM) positive mode respectively. The drug, metabolite and internal standards were extracted by liquid-liquid extraction method. The method was validated over a linear concentration range of 20.00-5000.00 pg/mL for tolterodine and 20.00-5000.00 pg/mL for 5-hydroxy methyl tolterodine. This method demonstrated intra- and inter-day precision of 0.62-6.36% and 1.73-4.84% for tolterodine, 1.38-4.22% and 1.62-4.25% for 5-hydroxy methyl tolterodine respectively. This method also demonstrated intra- and inter-day accuracy of 98.75-103.56% and 99.20-104.40% for tolterodine, 98.08-104.67% and 98.73-103.06% for 5-hydroxy methyl tolterodine respectively. Both analytes were found to be stable throughout freeze-thaw cycles, bench top and postoperative stability studies. This method was successfully applied for the pharmacokinetic analysis of rat plasma samples following i.v. administration.

  11. Mineral materials as feasible amendments to stabilize heavy metals in polluted urban soils.

    PubMed

    Zhang, Mingkui; Pu, Jincheng

    2011-01-01

    Four minerals, agricultural limestone (AL), rock phosphate (RP), palygorskite (PG), and calcium magnesium phosphate (CMP), were evaluated by means of chemical fractions of heavy metals in soils and concentrations of heavy metals in leachates from columns to determine their ability to stabilize heavy metals in polluted urban soils. Two urban soils (calcareous soil and acidic soil) polluted with cadmium, copper, zinc and lead were selected and amended in the laboratory with the mineral materials) for 12 months. Results indicated that application of the mineral materials reduced exchangeable metals in the sequence of Pb, Cd > Cu > Zn. The reduction of exchangeable fraction of heavy metals in the soils amended with different mineral materials followed the sequence of CMP, PG > AL > RP. Reductions of heavy metals leached were based on comparison with cumulative totals of heavy metals eluted through 12 pore volumes from an untreated soil. The reductions of the metals eluted from the calcareous soil amended with the RP, AL, PG and CMP were 1.98%, 38.89%, 64.81% and 75.93% for Cd, 8.51%, 40.42%, 60.64% and 55.32% for Cu, 1.76%, 52.94%, 70.00% and 74.12% for Pb, and 28.42%, 52.74%, 64.38% and 49.66% for Zn. Those from the acidic soil amended with the CMP, PG, AL, and RP were 25.65%, 68.06%, 78.01% and 79.06% for Cd, 26.56%, 49.64%, 43.40% and 34.68% for Cu, 44.44%, 33.32%, 61.11% and 69.44% for Pb, and 18.46%, 43.77%, 41.98% and 40.68% for Zn. The CMP and PG treatments were superior to the AL and RP for stabilizing heavy metals in the polluted urban soils.

  12. A RP-LC method with evaporative light scattering detection for the assay of simethicone in pharmaceutical formulations.

    PubMed

    Moore, Douglas E; Liu, Tina X; Miao, William G; Edwards, Alison; Elliss, Russell

    2002-09-05

    A reversed-phase liquid chromatographic method has been developed and validated for the determination of the polydimethylsiloxane (PDMS) component of Simethicone, which is used as an anti-foaming agent in pharmaceutical formulations. The method involves acidification to neutralise antacid components of the formulation, then a single extraction of the PDMS with dichloromethane. This is followed by separation with a reversed-phase column using an acetonitrile-chloroform solvent gradient, and quantification by an evaporative light scattering detector. An assay precision of 3% was achieved in intraday and interday determinations. No interference was found from the aluminium and magnesium hydroxide components of antacid formulations.

  13. Simultaneous quantification of naproxcinod and its active metabolite naproxen in rat plasma using LC-MS/MS: application to a pharmacokinetic study.

    PubMed

    Shi, Xiaowei; Shang, Weiding; Wang, Shuang; Xue, Na; Hao, Yanxia; Wang, Yabo; Sun, Mengmeng; Du, Yumin; Cao, Deying; Zhang, Kai; Shi, Qingwen

    2015-01-26

    In this study, a liquid chromatography-tandem mass spectrometry method was developed and validated to simultaneously determine naproxcinod and naproxen concentrations in rat plasma for the first time. Plasma samples were prepared by simple one-step extraction with methanol for protein precipitation using only 50 μL plasma. Separation was performed on a Synergi Fusion-RP C18 column with a run time of 4 min. Naproxcinod, naproxen and internal standard concentrations were detected in the positive ion mode using multiple reaction monitoring (MRM) of the transitions at m/z 348.2→302.2, 231.1→185.1 and 271.2→203.1, respectively. The calibration curves were linear, with all correlation coefficients being ≥0.9952, in the range of 1.00-400 ng/mL for naproxcinod and 20.0-8000 ng/mL for naproxen. Their accuracy was in the range of -8.1% to 8.7%, and the intra- and inter-day variations were ≤4.53%. The mean extraction recovery of all analytes was more than 93.1% efficient. Stability testing showed that naproxcinod and naproxen remained stable during the whole analytical procedure. After validation, the method was successfully applied to a pharmacokinetic study of naproxcinod and naproxen in rats. The AUC0-∞ of naproxen was 74.6 times larger than that of naproxcinod, which indicated that naproxcinod was rapidly metabolized into naproxen in rats. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Opposing PKA and Hog1 signals control the post-transcriptional response to glucose availability in Cryptococcus neoformans.

    PubMed

    Banerjee, Dithi; Bloom, Amanda L M; Panepinto, John C

    2016-10-01

    The pathogenic fungus Cryptococcus neoformans must adapt to glucose-limited conditions in the lung and glucose replete conditions upon dissemination to the brain. We report that glucose controls ribosome biogenesis and translation by modulating mRNA decay through a balance of PKA and Hog1 signalling. Glucose signalling through PKA stabilized ribosomal protein (RP) mRNAs whereas glucose starvation destabilized RP transcripts through Hog1. Glucose starvation-induced oxidative stress response genes, and treatment of glucose-fed cells with reactive oxygen species (ROS) generating compounds repressed RP transcripts, both of which were dependent on Hog1. Stabilization of RP transcripts led to retention of polysomes in a hog1Δ mutant, whereas stabilization of RP transcripts by cyclic AMP did not affect translation repression, suggesting that Hog1 alone signals translation repression. In sum, this work describes a novel antagonism between PKA and Hog1 controlling ribosome biogenesis via mRNA stability in response to glucose availability in this important human pathogen. © 2016 John Wiley & Sons Ltd.

  15. Effects of staining and bleaching on a nanohybrid composite with or without surface sealant

    PubMed Central

    Halacoglu, Derya Merve; Yamanel, Kıvanc; Basaran, Saffet; Tuncer, Duygu; Celik, Cigdem

    2016-01-01

    Objective: The effect of different staining solutions and a bleaching procedure on color stability and surface roughness of a nanohybrid resin composite were evaluated with or without liquid resin polishing (RP). Materials and Methods: Ninety-six disc-shaped resin composite specimens (A1 Shade, Z550 Filtek 3M ESPE, St. Paul, MN, USA) were prepared and divided randomly into two groups (n = 48). Liquid RP (BisCover LV, Bisco Inc., Schaumburg, IL, USA) was applied in one group (RP) and not in the other (P). Specimen color and surface roughness were determined using a colorimeter and profilometer, respectively. After baseline measurements, each group was divided into four subgroups (n = 12) for immersion in a control (distilled water) or three different staining solutions (ice tea, red wine, and cola) for 1 week. Color and surface roughness were then reevaluated. After measurements, all specimens were bleached using a 35% hydrogen peroxide gel. The color and surface roughness of the specimens were reevaluated. Statistical Analysis: Data were subjected to an analysis of variance for repeated measurements among the groups (P < 0.05). Results: Staining and bleaching did not change the surface roughness of the RP and P groups (P > 0.05). Discoloration in the red wine group was higher than for the other staining solutions for the RP (P < 0.001) and P groups (P = 0.018). Conclusion: Application of liquid RP did not enhance the color stability and surface roughness of the composite resin restoration. PMID:27403054

  16. Further investigations of the effect of pressure on retention in ultra-high-pressure liquid chromatography.

    PubMed

    Fallas, Morgane M; Neue, Uwe D; Hadley, Mark R; McCalley, David V

    2010-01-15

    In this study, we investigated further the large increases in retention with pressure that we observed previously in RP-LC especially for ionised solutes. These findings were initially confirmed on a conventional silica C(18) column, which gave extremely similar results to the hybrid C(18) phase originally used. Large increases in retention factor of approximately 50% for a pressure increase of 500 bar were also shown for high MW polar but neutral solutes. However, experiments with the same bases in ionised and non-ionised forms suggest that somewhat greater pressure-induced retention increases are found for ionised solutes. Retention increases with pressure were found to be considerably smaller for a C(1) column compared with a C(18) column; decreases in retention with increasing pressure were noted for ionised bases when using a bare silica column in the hydrophilic interaction chromatography (HILIC) mode. These observations are consistent with the partial loss of the solvation layer in RP-LC as the solute is forced into the hydrophobic environment of the stationary phase, and consequent reduction in the solute molar volume, while the water layer on the surface of a HILIC packing increases the hydration of a basic analyte. Finally, retention changes with pressure in RP-LC can also be observed at a mobile phase pH close to the solute pK(a), due to changes in pK(a) with pressure. However, this effect has no influence on the results of most of our studies. 2009 Elsevier B.V. All rights reserved.

  17. Stability-indicating RP-HPLC Method for the Simultaneous Determination of Sitagliptin and Simvastatin in Tablets

    PubMed Central

    Ramalingam, P.; Bhaskar, V. Udaya; Reddy, Y. Padmanabha; Kumar, K. Vinod

    2014-01-01

    A new stability-indicating high-performance liquid chromatographic method for simultaneous analysis of sitagliptin and simvastatin in pharmaceutical dosage form was developed and validated. The mobile phase consisted of methanol and water (70:30, v/v) with 0.2 % of n-heptane sulfonic acid adjusted to pH 3.0 with ortho phosphoric acid was used. Retentions of sitagliptin and simvastatin were 4.3 min and 30.4 min, respectively with a flow rate of 1 ml/min on C8 (Qualisil BDS, 250×4.6 mm, 5 μ). Eluents were detected at 253 nm using photodiode diode array detector. The linear regression analysis data for the linearity plot showed correlation coefficient values of 0.9998 and 0.9993 for sitagliptin and simvastatin, with respective concentration ranges of 20-150 μg/ml and 8-60 μg/ml. The relative standard deviation for inter-day precision was lower than 2.0%. The assay of sitagliptin and simvastatin was determined in tablet dosage form was found to be within limits. Both drugs were subjected to a variety of stress conditions such as acidic, basic, oxidation, photolytic, neutral and thermal stress in order to achieve adequate degradation. Results revealed that considerable degradation was found in all stress conditions except oxidative degradations. The method has proven specificity for stability indicating assay method. PMID:25425754

  18. High efficiency liquid chromatography techniques coupled to mass spectrometry for the characterization of mate extracts.

    PubMed

    Dugo, Paola; Cacciola, Francesco; Donato, Paola; Jacques, Rosângela Assis; Caramão, Elina Bastos; Mondello, Luigi

    2009-10-23

    There is growing interest related to rapid screening and full characterization of the constituents of plants with medicinal properties; among these, "Mate" or Yerba Maté is a tea-like beverage widely consumed in South America, obtained from the dried leaves of Ilex paraguariensis. The high content in polyphenols accounts for in vitro and in vivo antioxidant activity of the extracts obtained from this plant; on the other hand, the high complexity of the samples extracted, depending on the method employed, may preclude complete resolution by conventional HPLC techniques. For this purpose, a comprehensive two-dimensional liquid chromatography (LC x LC) system, comprised of an RP-Amide first dimension and a partially porous octadecylsilica column in the second dimension, has been compared with a one-dimensional system. The latter was operated using a partially porous octadecylsilica column, with diode array (DAD) and electrospray/ion trap-time of flight (ESI/IT-TOF) detection for the most complex extracts. The employment of the hybrid mass spectrometer allowed unequivocal identification of several compounds in the mate extracts. Using LC x LC-MS(3), it was possible to discriminate between congeners of chlorogenic acids, along with monoacyl- and diacylchlorogenic acid esters.

  19. Test verification of LOX/RP-1 high-pressure fuel/oxidizer-rich preburner designs

    NASA Technical Reports Server (NTRS)

    Lawver, B. R.

    1982-01-01

    Two fuel-rich and two oxidizer-rich preburner injectors are tested with LOX/RP-1 in an investigation of performance, stability and gas temperature uniformity over a chamber pressure range from 1292 to 2540 psia. Fuel-rich mixture ratios range from 0.238 to 0.367 and oxidizer-rich mixture ratios range from 27 to 48, and carbon deposition data are collected by measuring the pressure drop across a turbine simulator flow device. The oxidizer-rich testing demonstrates the feasibility of oxidizer-rich preburners, indicating equilibrium combustion as predicted, and the measured fuel-rich gas composition and C-asterisk performance are in excellent agreement with kinetic model predictions indicating kinetically-limited combustion.

  20. Quantitation of melatonin and n-acetylserotonin in human plasma by nanoflow LC-MS/MS and electrospray LC-MS/MS.

    PubMed

    Carter, Melissa D; Calcutt, M Wade; Malow, Beth A; Rose, Kristie L; Hachey, David L

    2012-03-01

    Melatonin (MEL) and its chemical precursor N-acetylserotonin (NAS) are believed to be potential biomarkers for sleep-related disorders. Measurement of these compounds, however, has proven to be difficult due to their low circulating levels, especially that of NAS. Few methods offer the sensitivity, specificity and dynamic range needed to monitor MEL and its precursors and metabolites in small blood samples, such as those obtained from pediatric patients. In support of our ongoing study to determine the safety, tolerability and PK dosing strategies for MEL in treating insomnia in children with autism spectrum disorder, two highly sensitive LC-MS/MS assays were developed for the quantitation of MEL and precursor NAS at pg/mL levels in small volumes of human plasma. A validated electrospray ionization (ESI) method was used to quantitate high levels of MEL in PK studies, and a validated nanospray (nESI) method was developed for quantitation of MEL and NAS at endogenous levels. In both assays, plasma samples were processed by centrifugal membrane dialysis after addition of stable isotopic internal standards, and the components were separated by either conventional LC using a Waters SymmetryShield RP18 column (2.1 × 100  mm, 3.5 µm) or on a polyimide-coated, fused-silica capillary self-packed with 17 cm AquaC18 (3 µm, 125 Å). Quantitation was done using the SRM transitions m/z 233 → 174 and m/z 219 → 160 for MEL and NAS, respectively. The analytical response ratio versus concentration curves were linear for MEL (nanoflow LC: 11.7-1165  pg/mL, LC: 1165-116,500  pg/mL) and for NAS (nanoflow LC: 11.0-1095  pg/mL). Copyright © 2012 John Wiley & Sons, Ltd.

  1. A rapid stability-indicating, fused-core HPLC method for simultaneous determination of β-artemether and lumefantrine in anti-malarial fixed dose combination products

    PubMed Central

    2013-01-01

    Background Artemisinin-based fixed dose combination (FDC) products are recommended by World Health Organization (WHO) as a first-line treatment. However, the current artemisinin FDC products, such as β-artemether and lumefantrine, are inherently unstable and require controlled distribution and storage conditions, which are not always available in resource-limited settings. Moreover, quality control is hampered by lack of suitable analytical methods. Thus, there is a need for a rapid and simple, but stability-indicating method for the simultaneous assay of β-artemether and lumefantrine FDC products. Methods Three reversed-phase fused-core HPLC columns (Halo RP-Amide, Halo C18 and Halo Phenyl-hexyl), all thermostated at 30°C, were evaluated. β-artemether and lumefantrine (unstressed and stressed), and reference-related impurities were injected and chromatographic parameters were assessed. Optimal chromatographic parameters were obtained using Halo RP-Amide column and an isocratic mobile phase composed of acetonitrile and 1mM phosphate buffer pH 3.0 (52:48; V/V) at a flow of 1.0 ml/min and 3 μl injection volume. Quantification was performed at 210 nm and 335 nm for β-artemether and for lumefantrine, respectively. In-silico toxicological evaluation of the related impurities was made using Derek Nexus v2.0®. Results Both β-artemether and lumefantrine were separated from each other as well as from the specified and unspecified related impurities including degradants. A complete chromatographic run only took four minutes. Evaluation of the method, including a Plackett-Burman robustness verification within analytical QbD-principles, and real-life samples showed the method is suitable for quantitative assay purposes of both active pharmaceutical ingredients, with a mean recovery relative standard deviation (± RSD) of 99.7 % (± 0.7%) for β-artemether and 99.7 % (± 0.6%) for lumefantrine. All identified β-artemether-related impurities were predicted in Derek Nexus v2.0® to have toxicity risks similar to β-artemether active pharmaceutical ingredient (API) itself. Conclusions A rapid, robust, precise and accurate stability-indicating, quantitative fused-core isocratic HPLC method was developed for simultaneous assay of β-artemether and lumefantrine. This method can be applied in the routine regulatory quality control of FDC products. The in-silico toxicological investigation using Derek Nexus® indicated that the overall toxicity risk for β-artemether-related impurities is comparable to that of β-artemether API. PMID:23631682

  2. Evaluation of reversed-phase nano liquid chromatography conditions by using reversed-phase thin layer chromatography based on Hansen solubility parameters for the analysis of amphiphilic glycosylsphingolipid transformations.

    PubMed

    Kanie, Yoshimi; Taniuchi, Mizuki; Kanie, Osamu

    2018-01-26

    Pulse chase analysis is often used in investigating dynamics of cellular substances. Fluorescently labeled lactosyl sphingosine molecule is useful in chasing its transformation, however the analysis of such metabolites in attomole level is of extreme difficult due to the presence of large amount of endogenous amphiphilic molecules such as glycosphingolipids, sphingomyerin, and glycerophospholipids. Nano LC suites for analyzing the attomole scale metabolites, therefore removal of endogenous substances prior to nano LC and finding appropriate nano LC conditions are necessary. Thus, we focused on the solubility of fluorescent BODIPY-labeled lactosylsphingosine (Lac-Sph-BODIPY) to identify suitable solvents to remove endogenous compounds. In this study, we evaluated solvents by using C18 thin layer chromatography (RP TLC). The mobility (R f ) of Lac-Sph-BODIPY against several solvent mixtures on RP TLC were plotted against polarity and hydrogen bonding capability followed by Hansen solubility parameters (HSPs). The optimum solvent mixture with R f  = 0.3 ± 0.1 was chosen for elimination of endogenous phospholipids on a ZrO 2 -SiO 2 cartridge column and subsequent separation by nano LC. Efficient removal of endogenous phospholipids was demonstrated, and good resolution in nano LC analysis of Lac-Sph-BODIPY extracted from Chinese hamster ovary (CHO)-K1 cells was achieved. It was also shown that the amount of exogenously added compound was important in the investigation of metabolites using cultured cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Control of linear modes in cylindrical resistive magnetohydrodynamics with a resistive wall, plasma rotation, and complex gain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brennan, D. P.; Finn, J. M.

    2014-10-15

    Feedback stabilization of magnetohydrodynamic (MHD) modes in a tokamak is studied in a cylindrical model with a resistive wall, plasma resistivity, viscosity, and toroidal rotation. The control is based on a linear combination of the normal and tangential components of the magnetic field just inside the resistive wall. The feedback includes complex gain, for both the normal and for the tangential components, and it is known that the imaginary part of the feedback for the former is equivalent to plasma rotation [J. M. Finn and L. Chacon, Phys. Plasmas 11, 1866 (2004)]. The work includes (1) analysis with a reducedmore » resistive MHD model for a tokamak with finite β and with stepfunction current density and pressure profiles, and (2) computations with a full compressible visco-resistive MHD model with smooth decreasing profiles of current density and pressure. The equilibria are stable for β = 0 and the marginal stability values β{sub rp,rw} < β{sub rp,iw} < β{sub ip,rw} < β{sub ip,iw} (resistive plasma, resistive wall; resistive plasma, ideal wall; ideal plasma, resistive wall; and ideal plasma, ideal wall) are computed for both models. The main results are: (a) imaginary gain with normal sensors or plasma rotation stabilizes below β{sub rp,iw} because rotation suppresses the diffusion of flux from the plasma out through the wall and, more surprisingly, (b) rotation or imaginary gain with normal sensors destabilizes above β{sub rp,iw} because it prevents the feedback flux from entering the plasma through the resistive wall to form a virtual wall. A method of using complex gain G{sub i} to optimize in the presence of rotation in this regime with β > β{sub rp,iw} is presented. The effect of imaginary gain with tangential sensors is more complicated but essentially destabilizes above and below β{sub rp,iw}.« less

  4. Interactions and release of two palmitoyl peptides from phytantriol cubosomes.

    PubMed

    Akhlaghi, Seyedeh Parinaz; Loh, Watson

    2017-08-01

    Phytantriol cubosomes loaded with two palmitoyl peptides (Palpepcubes), namely GHKcube and GQPRcube, were prepared using an ultrasonication protocol. The Palpepcubes dimensions were characterized by dynamic light scattering (DLS) and cryo-transmission electron microscopy (cryo-TEM). Small-angle X-ray scattering (SAXS) analyses revealed that the bicontinuous cubic structure remained even at palmitoyl peptide contents as high as 5wt.%, with an increase in the cell parameter from approximately 6.5 to 7.2nm. Isothermal titration calorimetry (ITC) was used to elucidate the interactions between the blank cubosomes and the palmitoyl peptides, revealing an exothermic process of interaction. Moreover, the in vitro release of the palmitoyl peptides from the Palpepcubes was studied using a dialysis method coupled with liquid chromatography-mass spectrometry (LC/MS) technique, in which a sustained release of up to a few days was observed. Finally, the stability of the aqueous solutions of the palmitoyl peptides and the Palpepcubes kept at room temperature and at low temperature (4°C) was studied by LC/MS method, indicating that incorporation into cubosomes increases the peptide stability significantly. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Synthesis, Self-Assembly, and Drug-Release Properties of New Amphipathic Liquid Crystal Polycarbonates

    PubMed Central

    Xie, Yujiao; Liu, Xiaofeng; Hu, Zhuang; Hou, Zhipeng; Chen, Zhangpei; Hu, Jianshe; Yang, Liqun

    2018-01-01

    New amphiphilic liquid crystal (LC) polycarbonate block copolymers containing side-chain cholesteryl units were synthesized. Their structure, thermal stability, and LC phase behavior were characterized with Fourier transform infrared (FT-IR) spectrum, 1H NMR, gel permeation chromatographic (GPC), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), polarizing optical microscope (POM), and XRD methods. The results demonstrated that the LC copolymers showed a double molecular arrangement of a smectic A phase at room temperature. With the elevating of LC unit content in such LC copolymers, the corresponding properties including decomposition temperature (Td), glass temperature (Tg), and isotropic temperature (Ti) increased. The LC copolymers showed pH-responsive self-assembly behavior under the weakly acidic condition, and with more side-chain LC units, the self-assembly process was faster, and the formed particle size was smaller. It indicated that the self-assembly driving force was derived from the orientational ability of LC. The particle size and morphologies of self-assembled microspheres loaded with doxorubicin (DOX), together with drug release tracking, were evaluated by dynamic light scattering (DLS), SEM, and UV–vis spectroscopy. The results showed that DOX could be quickly released in a weakly acidic environment due to the pH response of the self-assembled microspheres. This would offer a new strategy for drug delivery in clinic applications. PMID:29584691

  6. Determination of degradation products and process related impurities of asenapine maleate in asenapine sublingual tablets by UPLC

    NASA Astrophysics Data System (ADS)

    Kumar, Nitin; Sangeetha, D.; Kalyanraman, L.

    2017-11-01

    For determination of process related impurities and degradation products of asenapine maleate in asenapine sublingual Tablets, a reversed phase, stability indicating UPLC method was developed. Acetonitrile, methanol and potassium dihydrogen phosphate buffer with tetra-n- butyl ammonium hydrogen sulphate as ion pair (pH 2.2; 0.01 M) at flow rate of 0.2 ml/min were used in gradient elution mode. Separation was achieved by using acquity BEH Shield RP18 column (1.7 μm, 2.1 mm×100 mm) at 35 ºC. UV detection was performed at 228 nm. Subsequently the liquid chromatography method was validated as per ICH. The drug product was exposed to the stress conditions of acid hydrolysis, base hydrolysis, water hydrolysis, oxidative, thermal, and photolytic. In oxidative stress and thermal stress significant degradation was observed. All the degradation products were well separated from analyte peak and its impurities. Stability indicating nature of the method was proved by demonstrating the peak purity of Asenapine peak in all the stressed samples. The mass balance was found >95% for all the stress conditions. Based on method validation, the method was found specific, linear, accurate, precise, rugged and robust.

  7. High Reynolds Number Thermal Stability Experiments

    NASA Technical Reports Server (NTRS)

    Emens, Jessica M.; Brown, Sarah P.; Frederick Robert A., Jr.; Wood, A. John

    2004-01-01

    This work represents preliminary thermal stability results for liquid hydrocarbon fuels. High Reynolds Number Thermal Stability experiments with Jet A and RP-1 resulted in a quantitative measurement of the thermal stability. Each fuel flowed through a heated capillary tube that held the outlet temperature at 290 C. An optical pyrometer measured the surface temperature of the tube at 12 locations as a function of time. The High Reynolds Number Thermal Stability number was then determined using standards published by the American Society for Testing and Materials. The results for Jet A showed lower thermal stability than similar tests conducted at another facility. The RP-1 results are the first reported using this technique. Because the temperature rise on the capillary tube during testing for the RP-1 fuels was not significant, a new standard for the testing conditions should be developed for these types of fuels.

  8. New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations.

    PubMed

    Brozmanová, Hana; Kacířová, Ivana; Uřinovská, Romana; Šištík, Pavel; Grundmann, Milan

    2017-06-01

    A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH 4 OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were used. Mass detection was performed in positive electrospray mode. The results obtained with LC-MS/MS method were correlated with an FPIA assay (Abbott AxSYM) using mouse monoclonal antibody. Subjects were divided into three groups according to creatinine levels (53.5±19.1, 150.2±48.4, 471.7±124.7μmol/L) and Passing-Bablok regression analysis and Bland-Altman analysis were used to compare vancomycin concentrations. The results of subjects with both normal and higher creatinine levels correlated very well and the linear regression model equations were near ideal (LC-MS VAN =0.947×Abbott VAN +0.192 and LC-MS VAN =0.973×Abbott VAN -0.411 respectively). Dialyzed patients with the highest creatinine levels showed about 14% greater vancomycin concentration with the FPIA assay (LC-MS VAN =0.866×Abbott VAN +2.127). This overestimation probably due to the presence of the metabolite CDP ought not to be of clinical relevance owing to the wide range of recommended vancomycin concentration. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A Validated Stability-Indicating RP-UPLC Method for Simultaneous Determination of Desloratadine and Sodium Benzoate in Oral Liquid Pharmaceutical Formulations.

    PubMed

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy

    2012-01-01

    A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.

  10. Can Naturoptics Vision Improvement Methods Help Clear Cataracts, as Claimed by the Member of the Naturopathic Physicians Association of Massachusetts who Stabilized and/ or Improved Vision in all the Retinitis Pigmentosa, RP, Patients Treated by him?

    NASA Astrophysics Data System (ADS)

    MacDougall, Jean; McLeod, Roger

    2006-03-01

    Mac Dougall was advised against having a single crystalline lens with a slight cataract surgically removed; it would impact her ability to reengage vision's self-correcting feedback mechanisms. Her Florida ophthalmologist removed both lenses. A Massachusetts ophthalmologist was recently de-licensed for improperly performing just those services. An optometrist says reputed vision repair can easily be tracked and evaluated; we posit that Naturoptics effects on cataracts can be similarly assessed. ``Cures'' are detectable. Naturoptics users may show glaucoma reversal. EDWARD R. ELLIS, Jr., N.D. (The Chelmsford Clinic, Massachusetts), stabilizes RP, preventing blindness.

  11. A four parameter optimization and troubleshooting of a RPLC - charged aerosol detection stability indicating method for determination of S-lysophosphatidylcholines in a phospholipid formulation.

    PubMed

    Tam, James; Ahmad, Imad A Haidar; Blasko, Andrei

    2018-06-05

    A four parameter optimization of a stability indicating method for non-chromophoric degradation products of 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC), 1-stearoyl-sn-glycero-3-phosphocholine and 2-stearoyl-sn-glycero-3-phosphocholine was achieved using a reverse phase liquid chromatography-charged aerosol detection (RPLC-CAD) technique. Using the hydrophobic subtraction model of selectivity, a core-shell, polar embedded RPLC column was selected followed by gradient-temperature optimization, resulting in ideal relative peak placements for a robust, stability indicating separation. The CAD instrument parameters, power function value (PFV) and evaporator temperature were optimized for lysophosphatidylcholines to give UV absorbance detector-like linearity performance within a defined concentration range. The two lysophosphatidylcholines gave the same response factor in the selected conditions. System specific power function values needed to be set for the two RPLC-CAD instruments used. A custom flow-divert profile, sending only a portion of the column effluent to the detector, was necessary to mitigate detector response drifting effects. The importance of the PFV optimization for each instrument of identical build and how to overcome recovery issues brought on by the matrix effects from the lipid-RP stationary phase interaction is reported. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. [Study on the effect of rhizoma Chuanxiong, radix paeoniae rubra and the compound of their active ingredients, Xiongshao Capsule, on stability of atherosclerotic plaque in ApoE(-/-) mice].

    PubMed

    Xu, Hao; Wen, Chuan; Chen, Ke-Ji

    2007-06-01

    To observe the effect of Rhizoma chuanxiong (RC), Radix Paeoniae rubra (RP) and Xiongshao Capsule (XC, a compound of their active ingredients, Chuanxingols and Paeoniflorins) on stability of atherosclerotic plaque in ApoE-/- mice and to explore the probable mechanisms. The effect of RC, RP and XC in stabilizing atherosclerotic plaque, in terms of pathologic morphology, cell composition and inflammatory reaction, in the atherosclerosis model established on ApoE-/- mice was studied by using optical microscope, immunohistochemical method and computerized imaging analysis respectively. After the ApoE-/- mice being fed with high fat diet for 26 weeks, obvious atherosclerotic lesion with typical unstable characteristics was found in their aortic root. Both RC and RP had certain effects in lowering total cholesterol and increasing the thickness of fibre cap. RC could also lower the serum triglyceride (TC) level and the lipid-core/plaque area ratio as well as reduce the macrocytic infiltration. In addition to the same effects as above mentioned, XS could also raise the levels of high density lipoprotein-cholesterol (HDL-C), lower TC/HDL-C ratio, reduce inflammatory reaction and enlarge the collagen area in plaque. The acting links of RC and RP on atherosclerosis are different, the compound of their active ingredients, XS, shows a more evident effect in intervening unstable plaque. It demonstrates the effect-enhancing power of TCM compound and is worth further studying.

  13. Development of new method for simultaneous analysis of piracetam and levetiracetam in pharmaceuticals and biological fluids: application in stability studies.

    PubMed

    Siddiqui, Farhan Ahmed; Sher, Nawab; Shafi, Nighat; Wafa Sial, Alisha; Ahmad, Mansoor; Mehjebeen; Naseem, Huma

    2014-01-01

    RP-HPLC ultraviolet detection simultaneous quantification of piracetam and levetiracetam has been developed and validated. The chromatography was obtained on a Nucleosil C18 column of 25 cm×0.46 cm, 10 μm, dimension. The mobile phase was a (70:30 v/v) mixture of 0.1 g/L of triethylamine and acetonitrile. Smooth flow of mobile phase at 1 mL/min was set and 205 nm wavelength was selected. Results were evaluated through statistical parameters which qualify the method reproducibility and selectivity for the quantification of piracetam, levetiracetam, and their impurities hence proving stability-indicating properties. The proposed method is significantly important, permitting the separation of the main constituent piracetam from levetiracetam. Linear behavior was observed between 20 ng/mL and 10,000 ng/mL for both drugs. The proposed method was checked in bulk drugs, dosage formulations, physiological condition, and clinical investigations and excellent outcome was witnessed.

  14. Genetic analyses of Per.C6 cell clones producing a therapeutic monoclonal antibody regarding productivity and long-term stability.

    PubMed

    Tsuruta, Lilian Rumi; Lopes Dos Santos, Mariana; Yeda, Fernanda Perez; Okamoto, Oswaldo Keith; Moro, Ana Maria

    2016-12-01

    Genetic characterization of protein-producing clones represents additional value to cell line development. In the present study, ten Per.C6 clones producing a Rebmab100 monoclonal antibody were selected using two cloning methods: six clones originated from limiting dilution cloning and four by the automated colony picker ClonePix FL. A stability program was performed for 50 generations, including 4 batches distributed along the timeframe to determine specific productivity (Qp) maintenance. Four stable clones (two from limiting dilution and two from ClonePix FL) were further evaluated. The relative mRNA expression levels of both heavy chain (HC) and light chain (LC) genes were verified at generations 0, 30-35, and 50-55 of the stability program. At generations 0 and 30-35, LC gene expression level was higher than HC gene, whereas at generation 50-55, the opposite prevailed. A high correlation was observed between Qp and HC or LC mRNA expression level for all clones at each generation analyzed along the continuous culture. The mRNA stability study was performed at steady-state culture. The LC gene displayed a higher half-life and lower decay constant than HC gene, accounting for the higher observed expression level of LC mRNA in comparison to HC mRNA. Clone R6 was highlighted due its high Qp, mRNA expression levels, and mRNA stability. Besides the benefits of applying genetic characterization for the selection of stable and high-producing clones, the present study shows for the first time the correlation between Qp and HC or LC expression levels and also mRNA stability in clones derived from human cell line Per.C6(®).

  15. Extending metabolome coverage for untargeted metabolite profiling of adherent cultured hepatic cells.

    PubMed

    García-Cañaveras, Juan Carlos; López, Silvia; Castell, José Vicente; Donato, M Teresa; Lahoz, Agustín

    2016-02-01

    MS-based metabolite profiling of adherent mammalian cells comprises several challenging steps such as metabolism quenching, cell detachment, cell disruption, metabolome extraction, and metabolite measurement. In LC-MS, the final metabolome coverage is strongly determined by the separation technique and the MS conditions used. Human liver-derived cell line HepG2 was chosen as adherent mammalian cell model to evaluate the performance of several commonly used procedures in both sample processing and LC-MS analysis. In a first phase, metabolite extraction and sample analysis were optimized in a combined manner. To this end, the extraction abilities of five different solvents (or combinations) were assessed by comparing the number and the levels of the metabolites comprised in each extract. Three different chromatographic methods were selected for metabolites separation. A HILIC-based method which was set to specifically separate polar metabolites and two RP-based methods focused on lipidome and wide-ranging metabolite detection, respectively. With regard to metabolite measurement, a Q-ToF instrument operating in both ESI (+) and ESI (-) was used for unbiased extract analysis. Once metabolite extraction and analysis conditions were set up, the influence of cell harvesting on metabolome coverage was also evaluated. Therefore, different protocols for cell detachment (trypsinization or scraping) and metabolism quenching were compared. This study confirmed the inconvenience of trypsinization as a harvesting technique, and the importance of using complementary extraction solvents to extend metabolome coverage, minimizing interferences and maximizing detection, thanks to the use of dedicated analytical conditions through the combination of HILIC and RP separations. The proposed workflow allowed the detection of over 300 identified metabolites from highly polar compounds to a wide range of lipids.

  16. Nifedipine-loaded polymeric nanocapsules: validation of a stability-indicating HPLC method to evaluate the drug entrapment efficiency and in vitro release profiles.

    PubMed

    Granada, Andréa; Tagliari, Monika Piazzon; Soldi, Valdir; Silva, Marcos António Segatto; Zanetti-Ramos, Betina Ghiel; Fernandes, Daniel; Stulzer, Hellen Karine

    2013-01-01

    A simple stability-indicating analytical method was developed and validated to quantify nifedipine in polymeric nanocapsule suspensions; an in vitro drug release study was then carried out. The analysis was performed using an RP C18 column, UV-Vis detection at 262 nm, and methanol-water (70 + 30, v/v) mobile phase at a flow rate of 1.2 mL/min. The method was validated in terms of specificity, linearity and range, LOQ, accuracy, precision, and robustness. The results obtained were within the acceptable ranges. The nanocapsules, made of poly(epsilon-caprolactone), were prepared by the solvent displacement technique and showed high entrapment efficiency. The entrapment efficiency was 97.6 and 98.2% for the nifedipine-loaded polymeric nanocapsules prepared from polyvinyl alcohol (PVA) and Pluronic F68 (PF68), respectively. The particle size and zeta potential of nanocapsules were found to be influenced by the nature of the stabilizer used. The mean diameter and zeta potential for nanocapsules with PVA and PF68 were 290.9 and 179.9 nm, and -17.7 mV and -32.7 mV, respectively. The two formulations prepared showed a drug release of up to 70% over 4 days. This behavior indicates the viability of this drug delivery system for use as a controlled-release system.

  17. One-pot preparation of a mixed-mode organic-silica hybrid monolithic capillary column and its application in determination of endogenous gibberellins in plant tissues.

    PubMed

    Zhang, Zheng; Hao, Yan-Hong; Ding, Jun; Xu, Sheng-Nan; Yuan, Bi-Feng; Feng, Yu-Qi

    2015-10-16

    A newly improved one-pot method, based on "thiol-ene" click chemistry and sol-gel approach in microemulsion system, was developed for the preparation of C8/PO(OH)2-silica hybrid monolithic capillary column. The prepared monolith possesses large specific surface area, narrow mesopore size distribution and high column efficiency. The monolithic column was demonstrated to have cation exchange/reversed-phase (CX/RP) mixed-mode retention for analytes on nano-liquid chromatography (nano-LC). On the basis of the developed nano-LC system with MS detector coupled to pipette tip solid phase extraction (PT-SPE) and derivatization process, we then realized simultaneous determination of 10 gibberellins (GAs) with low limits of detection (LODs, 0.003-0.025 ng/mL). Furthermore, 6 endogenous GAs in only 5mg rice leaves (fresh weight) were successfully detected and quantified. The developed PT-SPE-nano-LC-MS strategy may offer promising applications in the determination of low abundant bioactive molecules from complex matrix. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Computerized nailfold video capillaroscopy--a new tool for assessment of Raynaud's phenomenon.

    PubMed

    Anderson, Marina E; Allen, P Danny; Moore, Tonia; Hillier, Val; Taylor, Christopher J; Herrick, Ariane L

    2005-05-01

    To develop a computer based nailfold video capillaroscopy system with enhanced image quality and to assess its disease-subgroup resolving power in patients with primary and secondary Raynaud's phenomenon (RP). Using frame registration software, digitized video images from the microscope were combined to form a panoramic mosaic of the nailfold. Capillary dimensions (apex, arterial, venous, and total width) and density were measured onscreen. Significantly, the new system could guarantee analysis of the same set of capillaries by 2 observers. Forty-eight healthy control subjects, 21 patients with primary RP, 40 patients with limited cutaneous systemic sclerosis (lcSSc), and 11 patients with diffuse cutaneous SSc (dcSSc) were studied. Intra- and interobserver variability were calculated in a subset of 30 subjects. The number of loops/mm was significantly lower, and all 4 capillary dimensions significantly greater, in SSc patients versus controls plus primary RP patients (p < 0.001 for all measures). When comparing control (+ primary RP) patients with SSc patients (lcSSc + dcSSc) the most powerful discriminator was found to be the number of loops/mm. Results for intra- and interobserver reproducibility showed that the limits of agreement were closer when both observers measured the same capillaries. The key feature of the newly developed system is that it improves reproducibility of nailfold capillary measurements by allowing reidentification of the same capillaries by different observers. By allowing access to previous measurements, the new system should improve reliability in longitudinal studies, and therefore has the potential of being a valuable outcome measure of microvessel disease/involvement in clinical trials of scleroderma spectrum disorders.

  19. High throughput screening of active pharmaceutical ingredients by UPLC.

    PubMed

    Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun

    2008-07-01

    Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.

  20. A Crystal Structure of the Dengue Virus Non-structural Protein 5 (NS5) Polymerase Delineates Interdomain Amino Acid Residues That Enhance Its Thermostability and de Novo Initiation Activities*

    PubMed Central

    Lim, Siew Pheng; Koh, Jolene Hong Kiew; Seh, Cheah Chen; Liew, Chong Wai; Davidson, Andrew D.; Chua, Leng Shiew; Chandrasekaran, Ramya; Cornvik, Tobias C.; Shi, Pei-Yong; Lescar, Julien

    2013-01-01

    The dengue virus (DENV) non-structural protein 5 (NS5) comprises an N-terminal methyltransferase and a C-terminal RNA-dependent RNA polymerase (RdRp) domain. Both enzymatic activities form attractive targets for antiviral development. Available crystal structures of NS5 fragments indicate that residues 263–271 (using the DENV serotype 3 numbering) located between the two globular domains of NS5 could be flexible. We observed that the addition of linker residues to the N-terminal end of the DENV RdRp core domain stabilizes DENV1–4 proteins and improves their de novo polymerase initiation activities by enhancing the turnover of the RNA and NTP substrates. Mutation studies of linker residues also indicate their importance for viral replication. We report the structure at 2.6-Å resolution of an RdRp fragment from DENV3 spanning residues 265–900 that has enhanced catalytic properties compared with the RdRp fragment (residues 272–900) reported previously. This new orthorhombic crystal form (space group P21212) comprises two polymerases molecules arranged as a dimer around a non-crystallographic dyad. The enzyme adopts a closed “preinitiation” conformation similar to the one that was captured previously in space group C2221 with one molecule per asymmetric unit. The structure reveals that residues 269–271 interact with the RdRp domain and suggests that residues 263–268 of the NS5 protein from DENV3 are the major contributors to the flexibility between its methyltransferase and RdRp domains. Together, these results should inform the screening and development of antiviral inhibitors directed against the DENV RdRp. PMID:24025331

  1. RP-1 and JP-8 Thermal Stability Experiments

    NASA Technical Reports Server (NTRS)

    Brown, Sarah P.; Emens, Jessica M.; Frederick, Robert A., Jr.

    2005-01-01

    This work experimentally investigates the effect of fuel composition changes on jet and rocket fuel thermal stability. A High Reynolds Number Thermal Stability test device evaluated JP-8 and RP-1 fuels. The experiment consisted of an electrically heated, stainless steel capillary tube with a controlled fuel outlet temperature. An optical pyrometer monitored the increasing external temperature profiles of the capillary tube as deposits build inside during each test. Multiple runs of each fuel composition provided results on measurement repeatability. Testing a t two different facilities provided data on measurement reproducibility. The technique is able to distinguish between thermally stable and unstable compositions of JP-8 and intermediate blends made by combining each composition. The technique is also able to distinguish among standard RP-1 rocket fuels and those having reduced sulfur levels. Carbon burn off analysis of residue in the capillary tubes on the RP-1 fuels correlates with the external temperature results.

  2. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples.

    PubMed

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula L N; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one.

  3. A New Rapid and Sensitive Stability-Indicating UPLC Assay Method for Tolterodine Tartrate: Application in Pharmaceuticals, Human Plasma and Urine Samples

    PubMed Central

    Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta

    2012-01-01

    A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907

  4. Liquid chromatography-tandem mass spectrometry detection of the quaternary ammonium compound mebezonium as an active ingredient in t61.

    PubMed

    Kirschbaum, Katrin M; Grellner, Wolfgang; Rochholz, Gertrud; Musshoff, Frank; Madea, Burkhard

    2011-03-01

    Quaternary ammonium compounds pose an analytical challenge. Mebezonium, a muscle-relaxing agent contained in veterinary euthanasia solution T61, was analyzed in body fluids, organs, and injection sites of a veterinarian by liquid chromatography-tandem mass spectrometry (LC-MS-MS) method. Additionally, embutramide and tetracaine, which are two other active ingredients contained in T61, methadone, xylazine, and analgesics were detected by LC-MS-MS and high-performance liquid chromatography-ultraviolet detection methods. For detection of mebezonium a solid-phase extraction (SPE) combined with ionpairing reagent heptafluorobutyric acid was developed. Separation was achieved on Phenomenex Synergi Hydro RP C(18) column combined with ammonium formate buffer and acetonitrile (pH 3.5). To enrich other drugs, liquid-liquid extraction procedures were used. Most of these drugs were separated on a Restek Allure PFP Propyl column using the mentioned mobile phase. Mebezonium and embutramide were detected in femoral vein serum in concentrations of 10.9 and 2.0 mg/L, respectively. The concentration of xylazine and methadone in serum was 2.0 and 0.4 mg/L, respectively. The LC-MS-MS method with SPE combined with an ion-pairing reagent allowed the quantitation of mebezonium. Methadone was detected in toxic concentrations and was, in combination with xylazine and T61, considered to be the cause of death.

  5. Quantitative determination of triterpenes from Amphiptherygium adstringens by liquid chromatography and thin-layer chromatography and morphological analysis of cuachalalate preparations.

    PubMed

    Navarrete, Andres; Avula, Bharathi; Joshi, Vaishali C; Ji, Xiuhong; Hersh, Paul; Khan, Ikhlas A

    2006-01-01

    Amphiptherygium adstringens (Anacardiaceae/Julianaceae), local name "cuachalalate," is used in folk medicine for the treatment of cholelithiasis, fevers, fresh wounds, hypercholesterolemia, gastritis, gastric ulcers, and cancer of the gastrointestinal tract. The development of column high-performance liquid chromatography-photodiode array detector (LC-PDA) and high-performance thin-layer chromatography (HPTLC)-densitometry methods for the determination of masticadienonic acid and 3-hydroxymasticadienonic acid in cuachalalate preparations is described in this paper. Good separation of the compounds could be achieved by both methods. Either might be preparable depending on the requirements. The LC separation was performed on a Phenomenex Synergi MAX-RP 80A reversed-phase column operated at 40 degrees C with detection at 215 nm. The plant materials were extracted with methanol by sonication. The triterpenes present in the plant material and commercial extracts were separated with an acetonitrile-water reagent alcohol isocratic system. The limit of detection was 0.1-0.2 microg/mL. The relative standard deviation values for the determination of triterpenes in plant extracts were less than 1.00%. This is the first report of an analytical method developed for the quantitative analysis of triterpenes from Amphiptherygium adstringens by LC-PDA and HPTLC. The stem bark showed higher amounts of triterpenes, and low amounts in root and stem root. The microscopic description of the crude drug of cuachalalate was also provided.

  6. Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextraction and liquid chromatography with post-column derivatization.

    PubMed

    Miralles, Pablo; Chisvert, Alberto; Alonso, M José; Hernandorena, Sandra; Salvador, Amparo

    2018-03-30

    An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid-liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography-ultraviolet/visible (LC-UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sample solution. The extracts were injected into the LC-UV/vis system using phosphate buffer 6 mmol L -1 at pH 2 as mobile phase. After chromatographic separation, the eluate merged with a flow stream of pentane-2,4-dione in ammonium acetate solution as derivatizing reagent and passed throughout a post-column reactor at 85 °C in order to derivatize formaldehyde into 3,5-diacetyl-1,4-dihydrolutidine, according to Hantzsch reaction, which was finally measured spectrophotometrically at 407 nm. The method was successfully validated showing good linearity, an enrichment factor of 86 ± 2, limits of detection and quantification of 0.7 and 2.3 ng mL -1 , respectively, and good repeatability (RSD < 9.2%). Finally, the proposed analytical method was applied to the determination of formaldehyde in different commercial cosmetic samples containing formaldehyde-releasing preservatives, such as bronopol, diazolidinyl urea, imidazolidinyl urea, and DMDM hydantoin, with good relative recovery values (91-113%) thus showing that matrix effects were negligible. The good analytical features of the proposed method besides of its simplicity and affordability, make it useful to carry out the quality control of cosmetic products containing formaldehyde-releasing preservatives. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Dual nozzle design update. [on liquid rocket engines for advanced earth-to-orbit transportation systems

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.

    1982-01-01

    Dual-nozzle engines, such as the dual-throat and dual-expander engines, are being evaluated for advanced earth-to-orbit transportation systems. Potential derivatives of the Space Shuttle and completely new vehicles might benefit from these advanced engines. In this paper, progress in the design of single-fuel and dual-fuel dual-nozzle engines is summarized. Dual-nozzle engines include those burning propellants such as LOX/RP-1/LH2, LOX/LC3H8/LH2, LOX/LCH4/LH2, LOX/LH2/LH2, LOX/LCH4/LCH4, LOX/LC3H8/C3H8 and N2O4/MMH/LH2. Engine data are applicable for thrust levels from 200,000 through 670,000 lbF. The results indicate that several versions of these engines utilize state-of-the-art technology and that even advanced versions of these engines do not require a major breakthrough in technology.

  8. Online Nanoflow Multidimensional Fractionation for High Efficiency Phosphopeptide Analysis*

    PubMed Central

    Ficarro, Scott B.; Zhang, Yi; Carrasco-Alfonso, Marlene J.; Garg, Brijesh; Adelmant, Guillaume; Webber, James T.; Luckey, C. John; Marto, Jarrod A.

    2011-01-01

    Despite intense, continued interest in global analyses of signaling cascades through mass spectrometry-based studies, the large-scale, systematic production of phosphoproteomics data has been hampered in-part by inefficient fractionation strategies subsequent to phosphopeptide enrichment. Here we explore two novel multidimensional fractionation strategies for analysis of phosphopeptides. In the first technique we utilize aliphatic ion pairing agents to improve retention of phosphopeptides at high pH in the first dimension of a two-dimensional RP-RP. The second approach is based on the addition of strong anion exchange as the second dimension in a three-dimensional reversed phase (RP)-strong anion exchange (SAX)-RP configuration. Both techniques provide for automated, online data acquisition, with the 3-D platform providing the highest performance both in terms of separation peak capacity and the number of unique phosphopeptide sequences identified per μg of cell lysate consumed. Our integrated RP-SAX-RP platform provides several analytical figures of merit, including: (1) orthogonal separation mechanisms in each dimension; (2) high separation peak capacity (3) efficient retention of singly- and multiply-phosphorylated peptides; (4) compatibility with automated, online LC-MS analysis. We demonstrate the reproducibility of RP-SAX-RP and apply it to the analysis of phosphopeptides derived from multiple biological contexts, including an in vitro model of acute myeloid leukemia in addition to primary polyclonal CD8+ T-cells activated in vivo through bacterial infection and then purified from a single mouse. PMID:21788404

  9. Qualitative identification of permitted and non-permitted colour additives in food products.

    PubMed

    Harp, Bhakti Petigara; Miranda-Bermudez, Enio; Baron, Carolina I; Richard, Gerald I

    2012-01-01

    Colour additives are dyes, pigments or other substances that can impart colour when added or applied to food, drugs, cosmetics, medical devices, or the human body. The substances must be pre-approved by the US Food and Drug Administration (USFDA) and listed in Title 21 of the US Code of Federal Regulations before they may be used in products marketed in the United States. Some also are required to be batch certified by the USFDA prior to their use. Both domestic and imported products sold in interstate commerce fall under USFDA jurisdiction, and the USFDA's district laboratories use a combination of analytical methods for identifying or confirming the presence of potentially violative colour additives. We have developed a qualitative method for identifying 17 certifiable, certification exempt, and non-permitted colour additives in various food products. The method involves extracting the colour additives from a product and isolating them from non-coloured components with a C(18) Sep-Pak cartridge. The colour additives are then separated and identified by liquid chromatography (LC) with photodiode array detection, using an Xterra RP18 column and gradient elution with aqueous ammonium acetate and methanol. Limits of detection (LODs) ranged from 0.02 to 1.49 mg/l. This qualititative LC method supplements the visible spectrophotometric and thin-layer chromatography methods currently used by the USFDA's district laboratories and is less time-consuming and requires less solvent compared to the other methods. The extraction step in the new LC method is a simple and an efficient process that can be used for most food types.

  10. Stability and characterization of perphenazine aerosols generated using the capillary aerosol generator.

    PubMed

    Li, Xihao; Blondino, Frank E; Hindle, Michael; Soine, William H; Byron, Peter R

    2005-10-13

    Perphenazine (a potent antiemetic) was aerosolized using capillary aerosol generator to generate respirable condensation aerosols from drug in propylene glycol (PG) solutions, by pumping the liquids through a heated capillary tube. The study characterized the stability of perphenazine during and following aerosol generation. The stability-indicating HPLC method (C-8 column with a mobile phase of 52% 0.01 M pH 3.0 acetate buffer+48% acetonitrile) also enabled the study of perphenazine stability in solution under acidic, basic, oxidizing and photolysing conditions. An LC-MS (ESI+) method was used to characterize the degradation products. Perphenazine was found to be stable in acidic and basic conditions, while perphenazine sulfoxide was the major product formed in dilute peroxide solutions. Two photo-degradation products were formed in PG that were tentatively identified by LC-MS; one of these was synthesized and confirmed to be 2-[4-(3-phenothiazin-10-yl-propyl)-piperazino]-ethanol. Both photolysis products showed that aromatic dechlorination had occurred and one appeared to also result from interaction with the solvent. Within an aerosolization energy window of 84-95 J, fine particle aerosols were generated from perphenazine PG formulations with no significant degradation. Small amounts of degradation products were produced in all samples during aerosolization at elevated (non-optimal) energies. These were largely consistent with those seen to result from oxidation and photolysis in solution, showing that oxidation and dehalogenation appeared to be the main degradation pathways followed when the CAG system was overheated.

  11. Stability Indicating HPLC Method for Simultaneous Determination of Mephenesin and Diclofenac Diethylamine

    PubMed Central

    Mulgund, S. V.; Phoujdar, M. S.; Londhe, S. V.; Mallade, P. S.; Kulkarni, T. S.; Deshpande, A. S.; Jain, K. S.

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 μg/ml and 10-60 μg/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H2O2, photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations. PMID:20177453

  12. Stability indicating HPLC method for simultaneous determination of mephenesin and diclofenac diethylamine.

    PubMed

    Mulgund, S V; Phoujdar, M S; Londhe, S V; Mallade, P S; Kulkarni, T S; Deshpande, A S; Jain, K S

    2009-01-01

    A simple, specific, accurate and stability-indicating reversed phase high performance liquid chromatographic method was developed for the simultaneous determination of mephenesin and diclofenac diethylamine, using a Spheri-5-RP-18 column and a mobile phase composed of methanol: water (70:30, v/v), pH 3.0 adjusted with o-phosphoric acid. The retention times of mephenesin and diclofenac diethylamine were found to be 3.9 min and 14.5 min, respectively. Linearity was established for mephenesin and diclofenac diethylamine in the range of 50-300 mug/ml and 10-60 mug/ml, respectively. The percentage recoveries of mephenesin and diclofenac diethylamine were found to be in the range of 99.06-100.60% and 98.95-99.98%, respectively. Both the drugs were subjected to acid, alkali and neutral hydrolysis, oxidation, dry heat, photolytic and UV degradation. The degradation studies indicated, mephenesin to be susceptible to neutral hydrolysis, while diclofenac diethylamine showed degradation in acid, H(2)O(2), photolytic and in presence of UV radiation. The degradation products of diclofenac diethylamine in acidic and photolytic conditions were well resolved from the pure drug with significant differences in their retention time values. This method can be successfully employed for simultaneous quantitative analysis of mephenesin and diclofenac diethylamine in bulk drugs and formulations.

  13. Oxidative stability and ignition quality of algae derived methyl esters containing varying levels of methyl eicosapentaenoate and methyl docosahexaenoate

    NASA Astrophysics Data System (ADS)

    Bucy, Harrison

    Microalgae is currently receiving strong consideration as a potential biofuel feedstock to help meet the advanced biofuels mandate of the 2007 Energy Independence and Security Act because of its theoretically high yield (gallons/acre/year) in comparison to current terrestrial feedstocks. Additionally, microalgae also do not compete with food and can be cultivated with wastewater on non-arable land. Microalgae lipids can be converted into a variety of biofuels including fatty acid methyl esters (e.g. FAME biodiesel), renewable diesel, renewable gasoline, or jet fuel. For microalgae derived FAME, the fuel properties will be directly related to the fatty acid composition of the lipids produced by the given microalgae strain. Several microalgae species under consideration for wide scale cultivation, such as Nannochloropsis, produce lipids with fatty acid compositions containing substantially higher quantities of long chainpolyunsaturated fatty acids (LC-PUFA) in comparison to terrestrial feedstocks. It is expected that increased levels of LC-PUFA will be problematic in terms of meeting all of the current ASTM specifications for biodiesel. For example, it is known that oxidative stability and cetane number decrease with increasing levels of LC-PUFA. However, these same LC-PUFA fatty acids, such as eicosapentaenoic acid (EPA: C20:5) and docosahexaenoic acid (DHA: C22:6) are known to have high nutritional value thereby making separation of these compounds economically attractive. Given the uncertainty in the future value of these LC-PUFA compounds and the economic viability of the separation process, the goal of this study was to examine the oxidative stability and ignition quality of algae-based FAME with varying levels of EPA and DHA removal. Oxidative stability tests were conducted at a temperature of 110°C and airflow of 10 L/h using a Metrohm 743 Rancimat with automatic induction period determination following the EN 14112 Method from the ASTM D6751 and EN 14214 Standards, which call for induction periods of at least three hours and six hours, respectively. Derived Cetane Number testing was conducted using a Waukesha FIT following the ASTM D7170 Method. Tests were conducted with synthetic algal oil blends manufactured from various sources to match the fatty acid compositions of several algae strains subjected to varying removal amounts of roughly 0 -- 100 percent LC-PUFA. In addition, tests were also conducted with real algal methyl esters produced from multiple sources. The bis-allylic position equivalent (BAPE) was calculated for each fuel sample to quantify the level of unsaturation. The induction period was then plotted as a function of BAPE, which showed that the oxidative stability varied exponentially with the amount of LC-PUFA. The results suggest that removal of 45 -- 65 percent of the LC-PUFA from Nannochloropsis-based algal methyl esters would be sufficient for meeting existing ASTM specifications for oxidative stability and 75 -- 85 percent removal would be needed to meet the EN specification. The oxidative stability additive tert-butylhydroquinone (THBQ) was found to increase Nannochloropsis-based algal methyl esters' oxidative stability to ASTM and EN specifications at only 0.03 percent and 0.06 percent additions by mass, respectively, when no LC-PUFA was removed. The ignition quality tests showed that the Derived Cetane Number varied linearly with BAPE and the algae formulations were found to pass the ASTM cetane specification of 47 only if all the LC-PUFA were removed.

  14. Lipidomic analysis of plasma in patients with lacunar infarction using normal-phase/reversed-phase two-dimensional liquid chromatography-quadrupole time-of-flight mass spectrometry.

    PubMed

    Yang, Li; Lv, Pu; Ai, Wanpeng; Li, Linnan; Shen, Sensen; Nie, Honggang; Shan, Yabing; Bai, Yu; Huang, Yining; Liu, Huwei

    2017-05-01

    Stroke is a major cause of mortality and long-term disability worldwide. The study of biomarkers and pathogenesis is vital for early diagnosis and treatment of stroke. In the present study, a continuous-flow normal-phase/reversed-phase two-dimensional liquid chromatography-quadrupole time-of-flight mass spectrometry (NP/RP 2D LC-QToF/MS) method was employed to measure lipid species in human plasma, including healthy controls and lacunar infarction (LI) patients. As a result, 13 lipid species were demonstrated with significant difference between the two groups, and a "plasma biomarker model" including glucosylceramide (38:2), phosphatidylethanolamine (35:2), free fatty acid (16:1), and triacylglycerol (56:5) was finally established. This model was evaluated as an effective tool in that area under the receiver operating characteristic curve reached 1.000 in the discovery set and 0.947 in the validation set for diagnosing LI patients from healthy controls. Besides, the sensitivity and specificity of disease diagnosis in validation set were 93.3% and 96.6% at the best cutoff value, respectively. This study demonstrates the promising potential of NP/RP 2D LC-QToF/MS-based lipidomics approach in finding bio-markers for disease diagnosis and providing special insights into the metabolism of stroke induced by small vessel disease. Graphical abstract Flow-chart of the plasma biomarker model establishment through biomarker screening and validation.

  15. Facile preparation of a stable and functionalizable hybrid monolith via ring-opening polymerization for capillary liquid chromatography.

    PubMed

    Lin, Hui; Ou, Junjie; Tang, Shouwan; Zhang, Zhenbin; Dong, Jing; Liu, Zhongshan; Zou, Hanfa

    2013-08-02

    An organic-inorganic hybrid monolith was prepared by a single-step ring-opening polymerization of octaglycidyldimethylsilyl polyhedral oligomeric silsesquioxane (POSS) with poly(ethylenimine) (PEI). The obtained hybrid monoliths possessed high ordered 3D skeletal microstructure with dual retention mechanism that exhibits reversed-phase (RP) mechanism under polar mobile phase and hydrophilic-interaction liquid chromatography (HILIC) retention mechanism under less polar mobile phase. The high column efficiencies of 110,000N/m can be achieved for separation of alkylbenzenes in capillary reversed-phase liquid chromatography (cLC). Due to the robust property of hybrid monolith and the rich primary and secondary amino groups on its surface, the resulting hybrid monolith was easily modified with γ-gluconolactone and physically coated with cellulose tris(3,5-dimethylphenylcarbamate) (CDMPC), respectively. The former was successfully applied for HILIC separation of neutral, basic and acidic polar compounds as well as small peptides, and the latter for enantioseparation of racemates in cLC. The high column efficiencies were achieved in all of those separations. These results demonstrated that the hybrid monolith (POSS-PEI) possessed high stability and good surface tailorbility, potentially being applied for other research fields. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Simultaneous determination of bifonazole and tinctures of calendula flower in pharmaceutical creams by reversed-phase liquid chromatography.

    PubMed

    Ferreyra, Carola F; Ortiz, Cristina S

    2005-01-01

    The aim of this research was to develop and validate a sensitive, rapid, easy, and precise reversed-phase liquid chromatography (LC) method for stability studies of bifonazole (I) formulated with tinctures of calendula flower (II). The method was especially developed for the analysis and quantitative determination of I and II in pure and combined forms in cream pharmaceutical formulations without using gradient elution and at room temperature. The influence on the stability of compound I of temperature, artificial radiation, and drug II used for the new pharmaceutical design was evaluated. The LC separation was carried out using a Supelcosil LC-18 column (25 cm x 4.6 mm id, 5 microm particle size); the mobile phase was composed of methanol-0.1 M ammonium acetate buffer (85 + 15, v/v) pumped isocratically at a flow rate of 1 mL/min; and ultraviolet detection was at 254 nm. The analysis time was less than 10 min. Calibration graphs were found to be linear in the 0.125-0.375 mg/mL (rI = 0.9991) and 0.639-1.916 mg/mL (rII = 0.9995) ranges for I and II, respectively. The linearity, precision, recovery, and limits of detection and quantification were satisfactory for I and II. The results obtained suggested that the developed LC method is selective and specific for the analysis of I and II in pharmaceutical products, and that it can be applied to stability studies.

  17. Thermal Stability of Rhodopsin and Progression of Retinitis Pigmentosa

    PubMed Central

    Liu, Monica Yun; Liu, Jian; Mehrotra, Devi; Liu, Yuting; Guo, Ying; Baldera-Aguayo, Pedro A.; Mooney, Victoria L.; Nour, Adel M.; Yan, Elsa C. Y.

    2013-01-01

    Over 100 point mutations in the rhodopsin gene have been associated with retinitis pigmentosa (RP), a family of inherited visual disorders. Among these, we focused on characterizing the S186W mutation. We compared the thermal properties of the S186W mutant with another RP-causing mutant, D190N, and with WT rhodopsin. To assess thermal stability, we measured the rate of two thermal reactions contributing to the thermal decay of rhodopsin as follows: thermal isomerization of 11-cis-retinal and hydrolysis of the protonated Schiff base linkage between the 11-cis-retinal chromophore and opsin protein. We used UV-visible spectroscopy and HPLC to examine the kinetics of these reactions at 37 and 55 °C for WT and mutant rhodopsin purified from HEK293 cells. Compared with WT rhodopsin and the D190N mutant, the S186W mutation dramatically increases the rates of both thermal isomerization and dark state hydrolysis of the Schiff base by 1–2 orders of magnitude. The results suggest that the S186W mutant thermally destabilizes rhodopsin by disrupting a hydrogen bond network at the receptor's active site. The decrease in the thermal stability of dark state rhodopsin is likely to be associated with higher levels of dark noise that undermine the sensitivity of rhodopsin, potentially accounting for night blindness in the early stages of RP. Further studies of the thermal stability of additional pathogenic rhodopsin mutations in conjunction with clinical studies are expected to provide insight into the molecular mechanism of RP and test the correlation between rhodopsin's thermal stability and RP progression in patients. PMID:23625926

  18. Unifying expression scale for peptide hydrophobicity in proteomic reversed phase high-pressure liquid chromatography experiments.

    PubMed

    Grigoryan, Marine; Shamshurin, Dmitry; Spicer, Victor; Krokhin, Oleg V

    2013-11-19

    As an initial step in our efforts to unify the expression of peptide retention times in proteomic liquid chromatography-mass spectrometry (LC-MS) experiments, we aligned the chromatographic properties of a number of peptide retention standards against a collection of peptides commonly observed in proteomic experiments. The standard peptide mixtures and tryptic digests of samples of different origins were separated under the identical chromatographic condition most commonly employed in proteomics: 100 Å C18 sorbent with 0.1% formic acid as an ion-pairing modifier. Following our original approach (Krokhin, O. V.; Spicer, V. Anal. Chem. 2009, 81, 9522-9530) the retention characteristics of these standards and collection of tryptic peptides were mapped into hydrophobicity index (HI) or acetonitrile percentage units. This scale allows for direct visualization of the chromatographic outcome of LC-MS acquisitions, monitors the performance of the gradient LC system, and simplifies method development and interlaboratory data alignment. Wide adoption of this approach would significantly aid understanding the basic principles of gradient peptide RP-HPLC and solidify our collective efforts in acquiring confident peptide retention libraries, a key component in the development of targeted proteomic approaches.

  19. LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma.

    PubMed

    Kiesel, Brian F; Parise, Robert A; Wong, Alvin; Keyvanjah, Kiana; Jacobs, Samuel; Beumer, Jan H

    2017-02-05

    Neratinib is an orally available tyrosine kinase inhibitor targeting HER2 (ERBB2) and EGFR (ERBB). It is being clinically evaluated for the treatment of breast and other solid tumors types as a single agent or in combination with other chemotherapies. In support of several phase I/II clinical trials investigating neratinib combinations, we developed and validated a novel LC-MS/MS assay for the quantification of neratinib in 100μL of human plasma with a stable isotopic internal standard. Analytes were extracted from plasma using protein precipitation and evaporation of the resulting supernatant followed by resuspension. Chromatographic separation was achieved using an Acquity UPLC BEH Shield RP18 column and a gradient methanol-water mobile phase containing 10% ammonium acetate. An ABI 4000 mass spectrometer and electrospray positive mode ionization were used for detection. The assay was linear from 2 to 1,000ng/mL and proved to be accurate (98.9-106.5%) and precise (<6.2%CV), and met the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be an essential tool to further define the pharmacokinetics of neratinib. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Kaempferol loaded lecithin/chitosan nanoparticles: preparation, characterization, and their potential applications as a sustainable antifungal agent.

    PubMed

    Ilk, Sedef; Saglam, Necdet; Özgen, Mustafa

    2017-08-01

    Flavonoid compounds are strong antioxidant and antifungal agents but their applications are limited due to their poor dissolution and bioavailability. The use of nanotechnology in agriculture has received increasing attention, with the development of new formulations containing active compounds. In this study, kaempferol (KAE) was loaded into lecithin/chitosan nanoparticles (LC NPs) to determine antifungal activity compared to pure KAE against the phytopathogenic fungus Fusarium oxysporium to resolve the bioavailability problem. The influence of formulation parameters on the physicochemical properties of KAE loaded lecithin chitosan nanoparticles (KAE-LC NPs) were studied by using the electrostatic self-assembly technique. KAE-LC NPs were characterized in terms of physicochemical properties. KAE has been successfully encapsulated in LC NPs with an efficiency of 93.8 ± 4.28% and KAE-LC NPs showed good physicochemical stability. Moreover, in vitro evaluation of the KAE-LC NP system was made by the release kinetics, antioxidant and antifungal activity in a time-dependent manner against free KAE. Encapsulated KAE exhibited a significantly inhibition efficacy (67%) against Fusarium oxysporium at the end of the 60 day storage period. The results indicated that KAE-LC NP formulation could solve the problems related to the solubility and loss of KAE during use and storage. The new nanoparticle system enables the use of smaller quantities of fungicide and therefore, offers a more environmentally friendly method of controlling fungal pathogens in agriculture.

  1. Development of New Method for Simultaneous Analysis of Piracetam and Levetiracetam in Pharmaceuticals and Biological Fluids: Application in Stability Studies

    PubMed Central

    Siddiqui, Farhan Ahmed; Sher, Nawab; Shafi, Nighat; Wafa Sial, Alisha; Ahmad, Mansoor; Mehjebeen

    2014-01-01

    RP-HPLC ultraviolet detection simultaneous quantification of piracetam and levetiracetam has been developed and validated. The chromatography was obtained on a Nucleosil C18 column of 25 cm × 0.46 cm, 10 μm, dimension. The mobile phase was a (70 : 30 v/v) mixture of 0.1 g/L of triethylamine and acetonitrile. Smooth flow of mobile phase at 1 mL/min was set and 205 nm wavelength was selected. Results were evaluated through statistical parameters which qualify the method reproducibility and selectivity for the quantification of piracetam, levetiracetam, and their impurities hence proving stability-indicating properties. The proposed method is significantly important, permitting the separation of the main constituent piracetam from levetiracetam. Linear behavior was observed between 20 ng/mL and 10000 ng/mL for both drugs. The proposed method was checked in bulk drugs, dosage formulations, physiological condition, and clinical investigations and excellent outcome was witnessed. PMID:25114921

  2. Development and application of a validated stability-indicating high-performance liquid chromatographic method using photodiode array detection for simultaneous determination of granisetron, methylparaben, propylparaben, sodium benzoate, and their main degradation products in oral pharmaceutical preparations.

    PubMed

    Hewala, Ismail; El-Fatatry, Hamed; Emam, Ehab; Mabrouk, Mokhtar

    2011-01-01

    A simple, rapid, and sensitive RP-HPLC method using photodiode array detection was developed and validated for the simultaneous determination of granisetron hydrochloride, 1-methyl-1H-indazole-3-carboxylic acid (the main degradation product of granisetron), sodium benzoate, methylparaben, propylparaben, and 4-hydroxybenzoic acid (the main degradation product of parabens) in granisetron oral drops and solutions. The separation of the compounds was achieved within 8 min on a SymmetryShield RP18 column (100 x 4.6 mm id, 3.5 microm particle size) using the mobile phase acetonitrile--0.05 M KH2PO4 buffered to pH 3 using H3PO4 (3+7, v/v). The photodiode array detector was used to test the purity of the peaks, and the chromatograms were extracted at 240 nm. The method was validated, and validation acceptance criteria were met in all cases. The robust method was successfully applied to the determination of granisetron and preservatives, as well as their degradation products in different batches of granisetron oral drops and solutions. The method proved to be sensitive for determination down to 0.04% (w/w) of granisetron degradation product relative to granisetron and 0.03% (w/w) 4-hydroxybenzoic acid relative to total parabens.

  3. Development and validation of polar RP-HPLC method for screening for ectoine high-yield strains in marine bacteria with green chemistry.

    PubMed

    Chen, Jun; Chen, Jianwei; Wang, Sijia; Zhou, Guangmin; Chen, Danqing; Zhang, Huawei; Wang, Hong

    2018-04-02

    A novel, green, rapid, and precise polar RP-HPLC method has been successfully developed and screened for ectoine high-yield strain in marine bacteria. Ectoine is a polar and extremely useful solute which allows microorganisms to survive in extreme environmental salinity. This paper describes a polar-HPLC method employed polar RP-C18 (5 μm, 250 × 4.6 mm) using pure water as the mobile phase and a column temperature of 30 °C, coupled with a flow rate at 1.0 mL/min and detected under a UV detector at wavelength of 210 nm. Our method validation demonstrates excellent linearity (R 2  = 0.9993), accuracy (100.55%), and a limit of detection LOQ and LOD of 0.372 and 0.123 μgmL -1 , respectively. These results clearly indicate that the developed polar RP-HPLC method for the separation and determination of ectoine is superior to earlier protocols.

  4. Online combination of reversed-phase/reversed-phase and porous graphitic carbon liquid chromatography for multicomponent separation of proteomics and glycoproteomics samples.

    PubMed

    Lam, Maggie P Y; Lau, Edward; Siu, S O; Ng, Dominic C M; Kong, Ricky P W; Chiu, Philip C N; Yeung, William S B; Lo, Clive; Chu, Ivan K

    2011-11-01

    In this paper, we describe an online combination of reversed-phase/reversed-phase (RP-RP) and porous graphitic carbon (PGC) liquid chromatography (LC) for multicomponent analysis of proteomics and glycoproteomics samples. The online RP-RP portion of this system provides comprehensive 2-D peptide separation based on sequence hydrophobicity at pH 2 and 10. Hydrophilic components (e.g. glycans, glycopeptides) that are not retained by RP are automatically diverted downstream to a PGC column for further trapping and separation. Furthermore, the RP-RP/PGC system can provide simultaneous extension of the hydropathy range and peak capacity for analysis. Using an 11-protein mixture, we found that the system could efficiently separate native peptides and released N-glycans from a single sample. We evaluated the applicability of the system to the analysis of complex biological samples using 25 μg of the lysate of a human choriocarcinoma cell line (BeWo), confidently identifying a total of 1449 proteins from a single experiment and up to 1909 distinct proteins from technical triplicates. The PGC fraction increased the sequence coverage through the inclusion of additional hydrophilic sequences that accounted for up to 6.9% of the total identified peptides from the BeWo lysate, with apparent preference for the detection of hydrophilic motifs and proteins. In addition, RP-RP/PGC is applicable to the analysis of complex glycomics samples, as demonstrated by our analysis of a concanavalin A-extracted glycoproteome from human serum; in total, 134 potentially N-glycosylated serum proteins, 151 possible N-glycosylation sites, and more than 40 possible N-glycan structures recognized by concanavalin A were simultaneously detected. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Stability indicating RP-HPLC method development and validation for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form.

    PubMed

    Siddiraju, S; Sahithi, M

    2015-03-01

    The objective of the present work is to develop stability indicating high-performance liquid chromatographic method for the simultaneous determination of aminexil and minoxidil in pharmaceutical dosage form. The chromatographic separation was achieved with BDS Hypersil C18 column (250 mm×4.6 mm×5 μ) as stationary phase and phosphate buffer and acetonitrile (78:22) as mobile phase. The method was employed by using a flow rate of 1.1 mL/min kept at 30°C. The detection wavelength was kept at 238 nm by using photo-diode array detector. The retention times of the aminexil and minoxidil were found to be 2.3 min and 3.9 min, respectively. The method developed was validated in accordance with ICH guidelines with respect to the stability indicating capacity of the method including system suitability, accuracy, precision, linearity, range, limit of detection, limit of quantification and robustness. The linearity responses of aminexil and minoxidil were found to be in the concentration ranges of 18.75-112.5 μg/mL and 25-150 μg/mL, respectively. The LOD and LOQ values for aminexil were found to be 0.31 and 0.92 μg/mL and minoxidil were found to be 0.03 and 0.10 μg/mL respectively. The percentage recoveries for both the drugs were found in the range of 98-101%. This method is accurate, precise and sensitive; hence, it can be employed for routine quality control of aminexil and minoxidil in pharmaceutical industries and drug testing laboratories. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  6. Fasting Increases Human Skeletal Muscle Net Phenylalanine Release and This Is Associated with Decreased mTOR Signaling

    PubMed Central

    Vendelbo, Mikkel Holm; Møller, Andreas Buch; Christensen, Britt; Nellemann, Birgitte; Clasen, Berthil Frederik Forrest; Nair, K. Sreekumaran; Jørgensen, Jens Otto Lunde; Jessen, Niels; Møller, Niels

    2014-01-01

    Aim Fasting is characterised by profound changes in energy metabolism including progressive loss of body proteins. The underlying mechanisms are however unknown and we therefore determined the effects of a 72-hour-fast on human skeletal muscle protein metabolism and activation of mammalian target of rapamycin (mTOR), a key regulator of cell growth. Methods Eight healthy male volunteers were studied twice: in the postabsorptive state and following 72 hours of fasting. Regional muscle amino acid kinetics was measured in the forearm using amino acid tracers. Signaling to protein synthesis and breakdown were assessed in skeletal muscle biopsies obtained during non-insulin and insulin stimulated conditions on both examination days. Results Fasting significantly increased forearm net phenylalanine release and tended to decrease phenylalanine rate of disappearance. mTOR phosphorylation was decreased by ∼50% following fasting, together with reduced downstream phosphorylation of 4EBP1, ULK1 and rpS6. In addition, the insulin stimulated increase in mTOR and rpS6 phosphorylation was significantly reduced after fasting indicating insulin resistance in this part of the signaling pathway. Autophagy initiation is in part regulated by mTOR through ULK1 and fasting increased expression of the autophagic marker LC3B-II by ∼30%. p62 is degraded during autophagy but was increased by ∼10% during fasting making interpretation of autophagic flux problematic. MAFbx and MURF1 ubiquitin ligases remained unaltered after fasting indicating no change in protesomal protein degradation. Conclusions Our results show that during fasting increased net phenylalanine release in skeletal muscle is associated to reduced mTOR activation and concomitant decreased downstream signaling to cell growth. PMID:25020061

  7. Development of LC-MS/MS method for the simultaneous analysis of the cardioprotective drug dexrazoxane and its metabolite ADR-925 in isolated cardiomyocytes and cell culture medium.

    PubMed

    Kovarikova, Petra; Pasakova-Vrbatova, Ivana; Vavrova, Anna; Stariat, Jan; Klimes, Jiri; Simunek, Tomas

    2013-03-25

    Dexrazoxane (DEX) is the only clinically used drug effective against anthracycline-induced cardiotoxicity and extravasation injury. However, the mechanism of its cardioprotective action still remains elusive. This paucity of comprehensive data is at least partially caused by the analytical difficulties associated with selective and sensitive simultaneous determination of the parent drug and its putative active metabolite ADR-925 in the relevant biological material. The aim of this study was to develop and validate the first LC-MS/MS method for simultaneous determination of DEX and ADR-925 in the isolated rat neonatal ventricular cardiomyocytes (NVCMs) and the cell culture medium. The analysis was performed on a Synergi Polar-RP column using the gradient profile of the mobile phase composed of 2mM ammonium formate and methanol. Electrospray ionization and ion trap mass analyzer were used as ionization and detection techniques, respectively. NVCMs were precipitated with methanol and the cell culture medium samples were diluted with the same solvent prior the LC-MS/MS analysis. The method was validated within the range of 4-80pmol/10(6) NVCMs and 7-70pmol/10(6) NVCMs for DEX and ADR-925, respectively, and at the concentrations of 8-100μM for both compounds in the culture cell medium. The practical applicability of this method was confirmed by the pilot analysis of NVCMs and the corresponding cell medium samples from relevant in vitro experiment. Hence, the LC-MS/MS method developed in this study represents a modern analytical tool suitable for investigation of DEX bioactivation inside the cardiomyocytes. In addition, the basic utility of the method for the analysis of DEX and ADR-925 in plasma samples was proved in a pilot experiment. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Bioanalytical Method for Carbocisteine in Human Plasma by Using LC-MS/MS: A Pharmacokinetic Application.

    PubMed

    Dhanure, Shivanand; Savalia, Atulkumar; More, Pravinkumar; Shirode, Prashant; Kapse, Kailas; Shah, Virag

    2014-01-01

    A simple, sensitive, and selective LC-MS/MS method was developed and validated for the quantification of carbocisteine in human plasma. Rosiglitazone was used as the internal standard and heparin was used as the anticoagulant. The chromatographic separation was performed by using the Waters Symmetry Shield RP 8, 150 × 3.9 mm, 5 μ column at 40°C with a mobile phase consisting of a mixture of methanol and 0.5% formic acid solution in a 40:60 proportion. The flow rate was 500 μl/min along with a 5 μl injection volume. Protein precipitation was used as the extraction method. Mass spectrometric data were detected in positive ion mode. The MRM mode of the ions for carbocisteine was 180.0 > 89.0 and for rosiglitazone it was 238.1 > 135.1. The method was validated in the concentration curve range of 50.000 ng/mL to 6000.000 ng/mL. The retention times of carbocisteine and the internal standard rosiglitazone were approximately 2.20 and 3.01 min, respectively. The overall run time was 4.50 min. This method was found suitable to analyze human plasma samples for the application in pharmacokinetic and BA/BE studies.

  9. Study of the interaction of 6-mercaptopurine with protein by microdialysis coupled with LC and electrochemical detection based on functionalized multi-wall carbon nanotubes modified electrode.

    PubMed

    Cao, Xu-Ni; Lin, Li; Zhou, Yu-Yan; Zhang, Wen; Shi, Guo-Yue; Yamamoto, Katsunobu; Jin, Li-Tong

    2003-07-14

    Microdialysis sampling coupled with liquid chromatography and electrochemical detection (LC-ECD) was developed and applied to study the interaction of 6-Mercaptopurine (6-MP) with bovine serum albumin (BSA). In the LC-ECD, the multi-wall carbon nanotubes fuctionalized with carboxylic groups modified electrode (MWNT-COOH CME) was used as the working electrode for the determination of 6-MP. The results indicated that this chemically modified electrode (CME) exhibited efficiently electrocatalytic oxidation for 6-MP with relatively high sensitivity, stability and long-life. The peak currents of 6-MP were linear to its concentrations ranging from 4.0 x 10(-7) to 1.0 x 10(-4) mol l(-1) with the calculated detection limit (S/N = 3) of 2.0 x 10(-7) mol l(-1). The method had been successfully applied to assess the association constant (K) and the number of the binding sites (n) on a BSA molecular, which calculated by Scatchard equation, were 3.97 x 10(3) mol(-1) l and 1.51, respectively. This method provided a fast, sensible and simple technique for the study of drug-protein interactions.

  10. Species Identification of Bovine, Ovine and Porcine Type 1 Collagen; Comparing Peptide Mass Fingerprinting and LC-Based Proteomics Methods.

    PubMed

    Buckley, Mike

    2016-03-24

    Collagen is one of the most ubiquitous proteins in the animal kingdom and the dominant protein in extracellular tissues such as bone, skin and other connective tissues in which it acts primarily as a supporting scaffold. It has been widely investigated scientifically, not only as a biomedical material for regenerative medicine, but also for its role as a food source for both humans and livestock. Due to the long-term stability of collagen, as well as its abundance in bone, it has been proposed as a source of biomarkers for species identification not only for heat- and pressure-rendered animal feed but also in ancient archaeological and palaeontological specimens, typically carried out by peptide mass fingerprinting (PMF) as well as in-depth liquid chromatography (LC)-based tandem mass spectrometric methods. Through the analysis of the three most common domesticates species, cow, sheep, and pig, this research investigates the advantages of each approach over the other, investigating sites of sequence variation with known functional properties of the collagen molecule. Results indicate that the previously identified species biomarkers through PMF analysis are not among the most variable type 1 collagen peptides present in these tissues, the latter of which can be detected by LC-based methods. However, it is clear that the highly repetitive sequence motif of collagen throughout the molecule, combined with the variability of the sites and relative abundance levels of hydroxylation, can result in high scoring false positive peptide matches using these LC-based methods. Additionally, the greater alpha 2(I) chain sequence variation, in comparison to the alpha 1(I) chain, did not appear to be specific to any particular functional properties, implying that intra-chain functional constraints on sequence variation are not as great as inter-chain constraints. However, although some of the most variable peptides were only observed in LC-based methods, until the range of publicly available collagen sequences improves, the simplicity of the PMF approach and suitable range of peptide sequence variation observed makes it the ideal method for initial taxonomic identification prior to further analysis by LC-based methods only when required.

  11. History of Sulphur Content Effects on the Thermal Stability of RP-1 under Heated Conditions

    NASA Technical Reports Server (NTRS)

    Irvine, Solveig A.; Schoettmer, Amanda K.; Bates, Ronald W.; Meyer, Michael L.

    2004-01-01

    As technologies advance in the aerospace industry, a strong desire has emerged to design more efficient, longer life, reusable liquid hydrocarbon fueled rocket engines. To achieve this goal, a more complete understanding of the thermal stability and chemical makeup of the hydrocarbon propellant is needed. Since the main fuel used in modern liquid hydrocarbon systems is RP-1, there is concern that Standard Grade RP-1 may not be a suitable propellant for future-generation rocket engines due to concern over the outdated Mil-Specification for the fuel. This current specification allows high valued limits on contaminants such as sulfur compounds, and also lacks specification of required thermal stability qualifications for the fuel. Previous studies have highlighted the detrimental effect of high levels of mercaptan sulfur content (^50 ppm) on copper rocket engine materials, but the fuel itself has not been studied. While the role of sulfur in other fuels (e.g., aviation, diesel, and automotive fuels) has been extensively studied, little has been reported on the effects of sulfur levels in rocket fuels. Lower RP-1 sulfur concentrations need to be evaluated and an acceptable sulfur limit established before RP-1 can be recommended for use as the propellant for future launch vehicles. (5 tables, 8 figures, 9 refs.)

  12. Determination of zearalenone and its metabolites in endometrial cancer by coupled separation techniques.

    PubMed

    Gadzała-Kopciuch, Renata; Cendrowski, Krzysztof; Cesarz, Anna; Kiełbasa, Paweł; Buszewski, Bogusław

    2011-10-01

    This study presents a selective method of isolation of zearalenone (ZON) and its metabolite, α-zearalenol (α-ZOL), in neoplastically changed human tissue by accelerated solvent and ultrasonic extractions using a mixture of acetonitrile/water (84/16% v/v) as the extraction solvent. Extraction effectiveness was determined through the selection of parameters (composition of the solvent mixture, temperature, pressure, number of cycles) with tissue contamination at the level of nanograms per gram. The produced acetonitrile/water extracts were purified, and analytes were enriched in columns packed with homemade molecularly imprinted polymers. Purified extracts were determined by liquid chromatography (LC) coupled with different detection systems (diode array detection--DAD and mass spectrometry--MS) involving the Ascentis RP-Amide as a stationary phase and gradient elution. The combination of UE-MISPE-LC (ultrasonic extraction--molecularly imprinted solid-phase extraction--liquid chromatography) produced high (R≈95-98%) and repeatable (RSD<3%) recovery values for ZON and α-ZOL. © The Author(s) 2011. This article is published with open access at Springerlink.com

  13. Deposit formation in hydrocarbon rocket fuels

    NASA Technical Reports Server (NTRS)

    Roback, R.; Szetela, E. J.; Spadaccini, L. J.

    1981-01-01

    An experimental program was conducted to study deposit formation in hydrocarbon fuels under flow conditions that exist in high-pressure, rocket engine cooling systems. A high pressure fuel coking test apparatus was designed and developed and was used to evaluate thermal decomposition (coking) limits and carbon deposition rates in heated copper tubes for two hydrocarbon rocket fuels, RP-1 and commercial-grade propane. Tests were also conducted using JP-7 and chemically-pure propane as being representative of more refined cuts of the baseline fuels. A parametric evaluation of fuel thermal stability was performed at pressures of 136 atm to 340 atm, bulk fuel velocities in the range 6 to 30 m/sec, and tube wall temperatures in the range 422 to 811 K. Results indicated that substantial deposit formation occurs with RP-1 fuel at wall temperatures between 600 and 800 K, with peak deposit formation occurring near 700 K. No improvements were obtained when deoxygenated JP-7 fuel was substituted for RP-1. The carbon deposition rates for the propane fuels were generally higher than those obtained for either of the kerosene fuels at any given wall temperature. There appeared to be little difference between commercial-grade and chemically-pure propane with regard to type and quantity of deposit. Results of tests conducted with RP-1 indicated that the rate of deposit formation increased slightly with pressure over the range 136 atm to 340 atm. Finally, lating the inside wall of the tubes with nickel was found to significantly reduce carbon deposition rates for RP-1 fuel.

  14. Reversed phase liquid chromatography with UV absorbance and flame ionization detection using a water mobile phase and a cyano propyl stationary phase Analysis of alcohols and chlorinated hydrocarbons.

    PubMed

    Quigley, W W; Ecker, S T; Vahey, P G; Synovec, R E

    1999-10-01

    The development of liquid chromatography with a commercially available cyano propyl stationary phase and a 100% water mobile phase is reported. Separations were performed at ambient temperature, simplifying instrumental requirements. Excellent separation efficiency using a water mobile phase was achieved, for example N=18 800, or 75 200 m(-1), was obtained for resorcinol, at a retention factor of k'=4.88 (retention time of 9.55 min at 1 ml min(-1) for a 25 cmx4.6 mm i.d. column, packed with 5 mum diameter particles with the cyano propyl stationary phase). A separation via reversed phase liquid chromatography (RP-LC) with a 100% water mobile phase of six phenols and related compounds was compared to a separation of the same compounds by traditional RP-LC, using octadecylsilane (ODS), i.e. C18, bound to silica and an aqueous mobile phase modified with acetonitrile. Nearly identical analysis time was achieved for the separation of six phenols and related compounds using the cyano propyl stationary phase with a 100% water mobile phase, as compared to traditional RP-LC requiring a relatively large fraction of organic solvent modifier in the mobile phase (25% acetonitrile:75% water). Additional understanding of the retention mechanism with the 100% water mobile phase was obtained by relating measured retention factors of aliphatic alcohols, phenols and related compounds, and chlorinated hydrocarbons to their octanol:water partition coefficients. The retention mechanism is found to be consistent with a RP-LC mechanism coupled with an additional retention effect due to residual hydroxyl groups on the cyano propyl stationary phase. Advantages due to a 100% water mobile phase for the chemical analysis of alcohol mixtures and chlorinated hydrocarbons are reported. By placing an absorbance detector in-series and preceding a novel drop interface to a flame ionization detector (FID), selective detection of a separated mixture of phenols and related compounds and aliphatic alcohols is achieved. The compound class of aliphatic alcohols is selectively and sensitively detected by the drop interface/FID, and the phenols and related compounds are selectively and sensitively detected by absorbance detection at 200 nm. The separation and detection of chlorinated hydrocarbons in a water sample matrix further illustrated the advantages of this methodology. The sensitivity and selectivity of the FID signal for the chlorinated hydrocarbons are significantly better than absorbance detection, even at 200 nm. This methodology is well suited to continuous and automated monitoring of water samples. The applicability of samples initially in an organic solvent matrix is explored, since an organic sample matrix may effect retention and efficiency. Separations in acetonitrile and isopropyl alcohol sample matrices compared well to separations with a water sample matrix.

  15. Stability Indicating Reverse Phase HPLC Method for Estimation of Rifampicin and Piperine in Pharmaceutical Dosage Form.

    PubMed

    Shah, Umang; Patel, Shraddha; Raval, Manan

    2018-01-01

    High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  16. Development and validation of a rapid stability indicating HPLC-method using monolithic stationary phase and two spectrophotometric methods for determination of antihistaminic acrivastine in capsules

    NASA Astrophysics Data System (ADS)

    Gouda, Ayman A.; Hashem, Hisham; Jira, Thomas

    2014-09-01

    Simple, rapid and accurate high performance liquid chromatographic (HPLC) and spectrophotometric methods are described for determination of antihistaminic acrivastine in capsules. The first method (method A) is based on accurate, sensitive and stability indicating chromatographic separation method. Chromolith® Performance RP-18e column, a relatively new packing material consisting of monolithic rods of highly porous silica, was used as stationary phase applying isocratic binary mobile phase of ACN and 25 mM NaH2PO4 pH 4.0 in the ratio of 22.5:77.5 at flow rate of 5.0 mL/min and 40 °C. A diode array detector was used at 254 nm for detection. The elution time of acrivastine was found to be 2.080 ± 0.032. The second and third methods (methods B and C) are based on the oxidation of acrivastine with excess N-bromosuccinimide (NBS) and determination of the unconsumed NBS with, metol-sulphanilic acid (λmax: 520 nm) or amaranth dye (λmax: 530 nm). The reacted oxidant corresponds to the drug content. Beer’s law is obeyed over the concentration range 1.563-50, 2.0-20 and 1.0-10 μg mL-1 for methods A, B and C, respectively. The limits of detection and quantitation were 0.40, 0.292 and 0.113 μg mL-1 and 0.782, 0.973 and 0.376 μg mL-1 for methods A, B and C, respectively. The HPLC method was validated for system suitability, linearity, precision, limits of detection and quantitation, specificity, stability and robustness. Stability tests were done through exposure of the analyte solution for four different stress conditions and the results indicate no interference of degradants with HPLC-method. The proposed methods was favorably applied for determination of acrivastine in capsules formulation. Statistical comparison of the obtained results from the analysis of the studied drug to those of the reported method using t- and F-tests showed no significant difference between them.

  17. Accumulation of three important bioactive compounds in different plant parts of Withania somnifera and its determination by the LC-ESI-MS-MS (MRM) method.

    PubMed

    Gajbhiye, Narendra A; Makasana, Jayanti; Kumar, Satyanshu

    2015-01-01

    A comprehensive experiment was conducted to study the accumulation pattern and determination of three important bioactive compounds namely withaferin-A (WA), 12-deoxywithastramonolide (WO) and withanolide-A (WD) and its determination by the liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS-MS) method in root, stem, fruits and leaves of Withania somnifera. A rapid and sensitive LC-ESI-MS-MS method was developed and validated for the determination of these three important bioactive compounds, having same molecular weight. The multiple reaction monitoring method was established by two transitions for each analyte and intense transition used for quantification. Separation of the three analytes was achieved within a run time of 5 min on an RP-18 column using a mobile phase consisting of acetonitrile and 0.1% acetic acid in water in an isocratic condition. The developed method was validated as per the ICH guidelines. The developed method was found to be suitable for identification and quantification of WA, WO and WD in different plant parts such as roots, stems, fruits and leaves of W. somnifera. The accumulation of WA was highest in leaves samples (8.84 ± 0.37 mg/g) and it was 2.23, 5.85 and 27.26 times higher than its concentration in fruits, stems and roots, respectively. WO and WD contents were highest (0.44 ± 0.016 and 0.72 ± 0.016 mg/g, respectively) in root. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Development and validation of a stability-indicating RP-HPLC-FLD method for determination of 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol; A novel drug candidate.

    PubMed

    Shehzadi, Naureen; Hussain, Khalid; Islam, Muhammad; Bukhari, Nadeem Irfan; Asif, Noman; Khan, Muhammad Tanveer; Salman, Muhammad; Qamar, Shaista; Parveen, Sajida; Zahid, Fakhra; Shah, Arshad Ali; Bilal, Abida; Abbasi, Muhammad Athar; Siddiqui, Sabahat Zahra; Rehman, Azizur

    2018-03-01

    The present study describes the development and validation of a simple high performance liquid chromatographic method for the determination of a novel drug candidate, 5-[(4-chlorophenoxy) methyl]-1, 3, 4-oxadiazole-2-thiol. The stability-indicating capacity of the method was evaluated by subjecting the compound's solution to hydrolytic, oxidative, photolytic, transition metal- and thermal- stress. The chromatographic separation was achieved over a C18 column (Promosil, 5 µm, 4.60 × 250 mm), maintained at 25°C, using an isocratic mobile phase comprising a mixture of acetonitrile and acidified water of pH 2.67 (1:1, v/v), at a flow rate of 1.00 mL/min and detection using a fluorescent light detector (excitation at 250 nm and emission at 410 nm). The Beer's law was followed over the concentration range 2.50-50.00 μg/ml. The recovery (98.56-100.19%, SD <5%), intraday accuracy and precision (97.31-100.81%, RSD <5%), inter-day accuracy and precision (97.50-100.75%, RSD <5%) and intermediate accuracy and precision (98.10-99.91%, RSD <5%) indicated that the method was reliable, repeatable, reproducible and rugged. The resolution and selectivity factors of the compound's peak from the nearest resolving peak, particularly in case of dry heat and copper metal stress, were found to be greater than 2 and 1, respectively, which indicated specificity and selectivity. The compound was extensively decomposed in alkaline-hydrolytic, oxidative, metal- and dry heat- stress. However, the compound in acidic and neutral conditions was resistant to photolysis. The results of the present study indicate that the developed method is specific, selective, sensitive and suitable, hence, may be used for quality control, stability testing and preformulation studies.

  19. Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

    NASA Technical Reports Server (NTRS)

    Kleinhenz, Julie E.; Deans, Matthew C.; Stiegemeier, Benjamin R.; Psaras, Peter M.

    2013-01-01

    A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

  20. Microfludic Sensing Devices Employing In Situ-Formed Liquid Crystal Thin Film for Detection of Biochemical Interactions1†

    PubMed Central

    Liu, Ye; Cheng, Daming; Lin, I-Hsin; Abbott, Nicholas L.; Jiang, Hongrui

    2012-01-01

    Although biochemical sensing using liquid crystals (LC) has been demonstrated, relatively little attention has been paid towards the fabrication of in situ-formed LC sensing devices. Herein, we demonstrate a highly reproducible method to create uniform LC thin film on treated substrates, as needed, for LC sensing. We use shear forces generated by the laminar flow of aqueous liquid within a microfluidic channel to create LC thin films stabilized within microfabricated structures. The orientational response of the LC thin films to targeted analytes in aqueous phases was transduced and amplified by the optical birefringence of the LC thin films. The biochemical sensing capability of our sensing devices was demonstrated through experiments employing two chemical systems: dodecyl trimethylammonium bromide (DTAB) dissolved in an aqueous solution, and the hydrolysis of phospholipids by the enzyme phospholipase A2 (PLA2). PMID:22842797

  1. What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner.

    PubMed

    Vaidya, Shrinand V; Virani, Siddharth; Phunde, Rajendra; Mahajan, Abhishek

    2016-01-01

    Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100' success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71' in the clinical score and about 58' in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan--Meier survivorship of 100'). We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias.

  2. Application of a novel liquid chromatography/tandem mass spectrometry method for the determination of antazoline in human plasma: Result of ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study.

    PubMed

    Giebułtowicz, Joanna; Piotrowski, Roman; Baran, Jakub; Kułakowski, Piotr; Wroczyński, Piotr

    2016-05-10

    Antazoline is a first-generation antihistaminic agent with antiarrhythmic quinidine-like properties. In some countries, it is widely used for termination of cardiac arrhythmias, especially atrial fibrillation (AF). However, no human pharmacokinetic studies have been conducted with intravenous antazoline. The aim of our study was to develop and validate a novel liquid chromatography/tandem mass spectrometry (LC-MS/MS) method for the determination of antazoline in human plasma: the ELEPHANT-I [ELEctrophysiological, pharmacokinetic and hemodynamic effects of PHenazolinum (ANTazoline mesylate)] human pharmacokinetic study. Antazoline was extracted from plasma using liquid-liquid extraction. The concentration of the analyte was measured by LC-MS/MS with xylometazoline as an internal standard. The method was validated for linearity, precision, accuracy, stability (freeze/thaw stability, stability in autosampler, short and long term stability), dilution integrity and matrix effect. The analyzed validation criteria were fulfilled. The method was applied to a pharmacokinetic study involving 10 healthy volunteers. Following a single intravenous dose of antazoline mesylate (100 mg), the plasma concentration profile showed a relative fast elimination with a terminal elimination half-life of 2.29 h. A relatively high volume of distribution was observed (Vss=315 L). The values of mean residence time (MRT∞), area under the curve (AUC∞) and clearance were 3.45 h, 0.91 mg h L(-1) and 80.5 L h(-1), respectively. One volunteer showed significant differences in pharmacokinetic parameters. In conclusion, the proposed new LC-MS/MS method was successfully used for the first time for the determination of antazoline in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Astragalin from Cassia alata Induces DNA Adducts in Vitro and Repairable DNA Damage in the Yeast Saccharomyces cerevisiae

    PubMed Central

    Saito, Samuel; Silva, Givaldo; Santos, Regineide Xavier; Gosmann, Grace; Pungartnik, Cristina; Brendel, Martin

    2012-01-01

    Reverse phase-solid phase extraction from Cassia alata leaves (CaRP) was used to obtain a refined extract. Higher than wild-type sensitivity to CaRP was exhibited by 16 haploid Saccharomyces cerevisiae mutants with defects in DNA repair and membrane transport. CaRP had a strong DPPH free radical scavenging activity with an IC50 value of 2.27 μg mL−1 and showed no pro-oxidant activity in yeast. CaRP compounds were separated by HPLC and the three major components were shown to bind to DNA in vitro. The major HPLC peak was identified as kampferol-3-O-β-d-glucoside (astragalin), which showed high affinity to DNA as seen by HPLC-UV measurement after using centrifugal ultrafiltration of astragalin-DNA mixtures. Astragalin-DNA interaction was further studied by spectroscopic methods and its interaction with DNA was evaluated using solid-state FTIR. These and computational (in silico) docking studies revealed that astragalin-DNA binding occurs through interaction with G-C base pairs, possibly by intercalation stabilized by H-bond formation. PMID:22489129

  4. Astragalin from Cassia alata induces DNA adducts in vitro and repairable DNA damage in the yeast Saccharomyces cerevisiae.

    PubMed

    Saito, Samuel; Silva, Givaldo; Santos, Regineide Xavier; Gosmann, Grace; Pungartnik, Cristina; Brendel, Martin

    2012-01-01

    Reverse phase-solid phase extraction from Cassia alata leaves (CaRP) was used to obtain a refined extract. Higher than wild-type sensitivity to CaRP was exhibited by 16 haploid Saccharomyces cerevisiae mutants with defects in DNA repair and membrane transport. CaRP had a strong DPPH free radical scavenging activity with an IC(50) value of 2.27 μg mL(-1) and showed no pro-oxidant activity in yeast. CaRP compounds were separated by HPLC and the three major components were shown to bind to DNA in vitro. The major HPLC peak was identified as kampferol-3-O-β-d-glucoside (astragalin), which showed high affinity to DNA as seen by HPLC-UV measurement after using centrifugal ultrafiltration of astragalin-DNA mixtures. Astragalin-DNA interaction was further studied by spectroscopic methods and its interaction with DNA was evaluated using solid-state FTIR. These and computational (in silico) docking studies revealed that astragalin-DNA binding occurs through interaction with G-C base pairs, possibly by intercalation stabilized by H-bond formation.

  5. Development and validation of stability indicating HPLC methods for related substances and assay analyses of amoxicillin and potassium clavulanate mixtures.

    PubMed

    Bellur Atici, Esen; Yazar, Yücel; Ağtaş, Çağan; Ridvanoğlu, Nurten; Karlığa, Bekir

    2017-03-20

    Antibacterial combinations consisting of the semisynthetic antibiotic amoxicillin (amox) and the β-lactamase inhibitor potassium clavulanate (clav) are commonly used and several chromatographic methods were reported for their quantification in mixtures. In the present work, single HPLC method for related substances analyses of amoxicillin and potassium clavulanate mixtures was developed and validated according to international conference on harmonization (ICH) guidelines. Eighteen amoxicillin and six potassium clavulanate impurities were successfully separated from each other by using triple gradient elution using a Thermo Hypersil Zorbax BDS C18 (250 mm×4.6mm, 3μm) column with 50μL injection volumes at a wavelength of 215nm. Commercially unavailable impurities were formed by degradation of amoxicillin and potassium clavulanate, identified by LC-MS studies and used during analytical method development and validation studies. Also, process related amoxicillin impurity-P was synthesized and characterized by using nuclear magnetic resonance (NMR) and mass spectroscopy (MS) for the first time. As complementary of this work, an assay method for amoxicillin and potassium clavulanate mixtures was developed and validated; stress-testing and stability studies of amox/clav mixtures was carried out under specified conditions according to ICH and analyzed by using validated stability-indicating assay and related substances methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Fully automated method for the liquid chromatographic determination of cyproterone acetate in plasma using restricted access material for sample pre-treatment.

    PubMed

    Christiaens, B; Chiap, P; Rbeida, O; Cello, D; Crommen, J; Hubert, Ph

    2003-09-25

    A new fully automated method for the quantitative analysis of an antiandrogenic substance, cyproterone acetate (CPA), in plasma samples has been developed using on-line solid-phase extraction (SPE) prior to the determination by reversed-phase liquid chromatography (LC). The automated method was based on the use of a precolumn packed with an internal-surface reversed-phase packing material (LiChrospher RP-4 ADS) for sample clean-up coupled to LC analysis on an octadecyl stationary phase using a column-switching system. A 200-microL volume of plasma sample was injected directly on the precolumn packed with restricted access material using a mixture of water-acetonitrile (90:10, v/v) as washing liquid. The analyte was then eluted in the back-flush mode with the LC mobile phase which consisted of a mixture of phosphate buffer, pH 7.0-acetonitrile (54:46, v/v). The elution profiles of CPA and blank plasma samples on the precolumn and the time needed for analyte transfer from the precolumn to the analytical column were determined. Different compositions of washing liquid and mobile phase were tested to reduce the interference of plasma endogenous components. UV detection was achieved at 280 nm. Finally, the developed method was validated using a new approach, namely the application of the accuracy profile based on the interval confidence at 90% of the total measurement error (bias+standard deviation). The limit of quantification of cyproterone acetate in plasma was determined at 15 ng mL(-1). The validated method should be applicable to the determination of CPA in patients treated by at least 50 mg day(-1).

  7. Chromatographic and Spectrophotometric Analysis of Phenolic Compounds from Fruits of Libidibia ferrea Martius

    PubMed Central

    Ferreira, Magda R. A.; Fernandes, Mônica T. M.; da Silva, Wliana A. V.; Bezerra, Isabelle C. F.; de Souza, Tatiane P.; Pimentel, Maria F.; Soares, Luiz A. L.

    2016-01-01

    Background: Libidibia ferrea (Mart. ex Tul.) L.P. Queiroz (Fabaceae) is a tree which is native to Brazil, widely known as “Jucá,” where its herbal derivatives are used in folk medicine with several therapeutic properties. The constituents, which have already been described in the fruit, are mainly hydrolysable tannins (gallic acid [GA] and ellagic acid [EA]). Objective: The aim of this study was to investigate the phenolic variability in the fruit of L. ferrea by ultraviolet/visible (UV/VIS) and chromatographic methods (high-performance liquid chromatography [HPLC]/high-performance thin layer chromatography [HPTLC]). Materials and Methods: Several samples were collected from different regions of Brazil and the qualitative (fingerprints by HPTLC and HPLC) and quantitative analysis (UV/VIS and HPLC) of polyphenols were performed. Results: The HPTLC and HPLC profiles allowed separation and identification of both major analytical markers: EA and GA. The chemical profiles were similar in a number of spots or peaks for the samples, but some differences could be observed in the intensity or area of the analytical markers for HPTLC or HPLC, respectively. Regarding the quantitative analysis, the polyphenolic content by UV/VIS ranged from 13.99 to 37.86 g% expressed as GA or from 10.75 to 29.09 g% expressed as EA. The contents of EA and GA by liquid chromatography-reversed phase (LC-RP) method ranged from 0.57 to 2.68 g% and from 0.54 to 3.23 g%, respectively. Conclusion: The chemical profiles obtained by HPTLC or HPLC, as well as the quantitative analysis by spectrophotometry or LC-RP method, were suitable for discrimination of each herbal sample and can be used as tools for the comparative analysis of the fruits from L. ferrea. SUMMARY The polyphenols of fruits of Libidibia ferrea can be quantified by UV/VIS and HPLCThe HPLC method was able to detect the gallic and ellagic acids in several samples of fruits of Libidibia ferreaThe phenolic profiles of fruits from Libidibia ferrea by HPTLC and HPLC were reproductible. Abbreviations used: HPTLC: high performance thin layer chromatography, HPLC: high performance liquid chromatography, UV-Vis: spectrophotometry PMID:27279721

  8. Generation of “Virtual” Control Groups for Single Arm Prostate Cancer Adjuvant Trials

    PubMed Central

    Koziol, James A.; Chen, Xin; Xia, Xiao-Qin; Wang, Yipeng; Skarecky, Douglas; Sutton, Manuel; Sawyers, Anne; Ruckle, Herbert; Carpenter, Philip M.; Wang-Rodriguez, Jessica; Jiang, Jun; Deng, Mingsen; Pan, Cong; Zhu, Jian-guo; McLaren, Christine E.; Gurley, Michael J.; Lee, Chung; McClelland, Michael; Ahlering, Thomas; Kattan, Michael W.; Mercola, Dan

    2014-01-01

    It is difficult to construct a control group for trials of adjuvant therapy (Rx) of prostate cancer after radical prostatectomy (RP) due to ethical issues and patient acceptance. We utilized 8 curve-fitting models to estimate the time to 60%, 65%, … 95% chance of progression free survival (PFS) based on the data derived from Kattan post-RP nomogram. The 8 models were systematically applied to a training set of 153 post-RP cases without adjuvant Rx to develop 8 subsets of cases (reference case sets) whose observed PFS times were most accurately predicted by each model. To prepare a virtual control group for a single-arm adjuvant Rx trial, we first select the optimal model for the trial cases based on the minimum weighted Euclidean distance between the trial case set and the reference case set in terms of clinical features, and then compare the virtual PFS times calculated by the optimum model with the observed PFSs of the trial cases by the logrank test. The method was validated using an independent dataset of 155 post-RP patients without adjuvant Rx. We then applied the method to patients on a Phase II trial of adjuvant chemo-hormonal Rx post RP, which indicated that the adjuvant Rx is highly effective in prolonging PFS after RP in patients at high risk for prostate cancer recurrence. The method can accurately generate control groups for single-arm, post-RP adjuvant Rx trials for prostate cancer, facilitating development of new therapeutic strategies. PMID:24465467

  9. Generation of "virtual" control groups for single arm prostate cancer adjuvant trials.

    PubMed

    Jia, Zhenyu; Lilly, Michael B; Koziol, James A; Chen, Xin; Xia, Xiao-Qin; Wang, Yipeng; Skarecky, Douglas; Sutton, Manuel; Sawyers, Anne; Ruckle, Herbert; Carpenter, Philip M; Wang-Rodriguez, Jessica; Jiang, Jun; Deng, Mingsen; Pan, Cong; Zhu, Jian-Guo; McLaren, Christine E; Gurley, Michael J; Lee, Chung; McClelland, Michael; Ahlering, Thomas; Kattan, Michael W; Mercola, Dan

    2014-01-01

    It is difficult to construct a control group for trials of adjuvant therapy (Rx) of prostate cancer after radical prostatectomy (RP) due to ethical issues and patient acceptance. We utilized 8 curve-fitting models to estimate the time to 60%, 65%, … 95% chance of progression free survival (PFS) based on the data derived from Kattan post-RP nomogram. The 8 models were systematically applied to a training set of 153 post-RP cases without adjuvant Rx to develop 8 subsets of cases (reference case sets) whose observed PFS times were most accurately predicted by each model. To prepare a virtual control group for a single-arm adjuvant Rx trial, we first select the optimal model for the trial cases based on the minimum weighted Euclidean distance between the trial case set and the reference case set in terms of clinical features, and then compare the virtual PFS times calculated by the optimum model with the observed PFSs of the trial cases by the logrank test. The method was validated using an independent dataset of 155 post-RP patients without adjuvant Rx. We then applied the method to patients on a Phase II trial of adjuvant chemo-hormonal Rx post RP, which indicated that the adjuvant Rx is highly effective in prolonging PFS after RP in patients at high risk for prostate cancer recurrence. The method can accurately generate control groups for single-arm, post-RP adjuvant Rx trials for prostate cancer, facilitating development of new therapeutic strategies.

  10. Molecular analysis of an oyster-related norovirus outbreak.

    PubMed

    Nenonen, Nancy P; Hannoun, Charles; Olsson, Margareta B; Bergström, Tomas

    2009-06-01

    Contaminated raw oysters were implicated in a severe outbreak of norovirus (NoV) gastroenteritis affecting 30 restaurant guests. To define the outbreak source by using molecular methods to characterize NoV strains detected in patient and oyster samples. Molecular epidemiological studies based on nucleotide sequencing and phylogenetic analyses of patient and oyster NoV strains, and comparison to background dataset. NoV genotype (G) I.1 was detected in the one patient stool analyzed by in-house TaqMan real time RT-PCR and classical nested RT-PCR targeting NoV RNA-dependent polymerase (RdRp, 285 nt), and by nested RT-PCR targeting RdRp-capsid-poly(A)-3' (3085 nt). Patient strain showed >or=99% similarity (285 nt) with three NoV strains detected in two of five oysters examined by classical nested RT-PCR (RdRp). A third oyster tested positive for NoV GII.3. Phylogenetic analysis showed clustering of patient and oyster strains related to this outbreak with GI.1 strains from previous local outbreaks, and mussel studies. Sequence data revealed >or=99% similarity (285 nt) between NoV GI.1 strains detected in patient stool and suspect oysters, linking the contaminated oysters to the outbreak. Identification of human NoV GI and GII strains in oysters indicated contamination of human fecal origin, presumably from inappropriate storage in the harbor. Comparative long-fragment analysis of the patient strain revealed 99% similarity (3085 nt) with NoV GI.1 strains detected in previous outbreaks and environmental mussel studies from West Sweden, 87% with M87661 (Norwalk68) and 96% with L23828 (SRSV-KY-89/89/J). These results indicated considerable genomic stability of NoV GI.1 strains over time.

  11. Analysis of tricyclic antidepressant drugs in plasma by means of solid-phase microextraction-liquid chromatography-mass spectrometry.

    PubMed

    Alves, Claudete; Santos-Neto, Alvaro J; Fernandes, Christian; Rodrigues, José C; Lanças, Fernando M

    2007-10-01

    Solid-phase microextraction coupled to liquid chromatography and mass spectrometry (SPME-LC-MS) was used to analyze tricyclic antidepressant drugs desipramine, imipramine, nortriptyline, amitriptyline, and clomipramine (internal standard) in plasma samples. SPME was performed by direct extraction on a PDMS/DVB (60 microm) coated fiber, employing a stirring rate of 1200 rpm for 30 min, pH 11.0, and temperature of 30 degrees C. Drug desorption was carried out by exposing the fiber to the liquid chromatography mobile phase for 20 min, using a labmade SPME-LC interface at 50 degrees C. The main variables experimentally influencing LC-MS response were evaluated and mathematically modeled. A rational optimization with fewer experiments was achieved using a factorial design approach. The constructed empirical models were adjusted with 96-98% of explained deviation allowing an adequate data set comprehension. The chromatographic separation was realized using an RP-18 column (150 mm x 2.1 mm, 5 microm particles) and ammonium acetate buffer (0.01 mol/l, pH 5.50) : acetonitrile (50 : 50 v/v) as mobile phase. Low detection levels were achieved with electrospray interface (0.1 ng/ml). The developed method showed specificity, linearity, precision, and limit of quantification adequate to assay tricyclic antidepressant drugs in plasma.

  12. LC-ESI-MS/MS determination of 4-methylpyrazole in dog plasma and its application to a pharmacokinetic study in dogs.

    PubMed

    Chandrasekhar, Devaraj V; Suresh, Ponnayyan Sulochana; Dittakavi, Sreekanth; Hiremath, Rakesh A; Bhamidipati, Ravi Kanth; Richter, Wolfgang; Srinivas, Nuggehally R; Mullangi, Ramesh

    2018-02-01

    A simple, specific, sensitive and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of 4-methylpyrazole in dog plasma using N-methylnicotinamide-d 4 as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a simple protein precipitation. Chromatographic separation of 4-methylpyrazole and the IS was performed on a monolithic (Chromolith RP 18e ) column using an isocratic mobile phase comprising 0.2% formic acid in water and acetonitrile (20:80, v/v) at a flow rate of 1.0 mL/min. Elution of 4-methylpyrazole and the IS occurred at ~1.60 and 1.56 min, respectively. The total chromatographic run time was 3.2 min. A linear response function was established in the concentration range of 4.96-4955 ng/mL. The intra- and inter-day accuracy and precision were in the ranges 1.81-12.9 and 3.80-11.1%, respectively. This novel method has been applied to a pharmacokinetic study in dogs. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Development of validated stability indicating assay method for simultaneous estimation of metformin hydrochloride and vildagliptin by RP-HPLC.

    PubMed

    Satheeshkumar, N; Pradeepkumar, M; Shanthikumar, S; Rao, V J

    2014-03-01

    A simple, precise and stability-indicating HPLC method was developed and validated for the simultaneous determination of metformin hydrochloride (MET) and vildagliptin (VLG) in pharmaceutical dosage forms. The method involves use of easily available inexpensive laboratory reagents. The separation was achieved on Grace Cyano column (250 mm×4.6 mm) 5 µm with isocratic flow. The mobile phase was pumped at a flow rate of 1.0 mL/min, consisted of 25 mM ammonium bicarbonate buffer and acetonitrile (65:35, v/v). The UV detection was carried out at 207 nm. A linear response was observed over the concentration range of 25-125 µg/mL for MET and 50-250 µg/mL for VLG respectively. Limit of detection and limit of quantification for MET were 0.36 µg/mL and 1.22 µg/mL, and for VLG were 0.75 µg/mL and 2.51 µg/mL respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for specificity, linearity, accuracy, precision, robustness, and system suitability. Individual drugs (MET and VLG) were exposed to thermal, photolytic, hydrolytic and oxidative stress conditions. The resultant stressed samples were analyzed by the proposed method. The method gave high resolution among the degradation products and the analytes. The peak purity of analyte peak in the stressed samples was confirmed by photo diode array detector. The proposed method was successfully applied for the quantitative analysis of MET and VLG in tablet dosage form, which will help to improve quality control and contribute to stability studies of pharmaceutical tablets containing these drugs. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Rapid and accurate prediction of degradant formation rates in pharmaceutical formulations using high-performance liquid chromatography-mass spectrometry.

    PubMed

    Darrington, Richard T; Jiao, Jim

    2004-04-01

    Rapid and accurate stability prediction is essential to pharmaceutical formulation development. Commonly used stability prediction methods include monitoring parent drug loss at intended storage conditions or initial rate determination of degradants under accelerated conditions. Monitoring parent drug loss at the intended storage condition does not provide a rapid and accurate stability assessment because often <0.5% drug loss is all that can be observed in a realistic time frame, while the accelerated initial rate method in conjunction with extrapolation of rate constants using the Arrhenius or Eyring equations often introduces large errors in shelf-life prediction. In this study, the shelf life prediction of a model pharmaceutical preparation utilizing sensitive high-performance liquid chromatography-mass spectrometry (LC/MS) to directly quantitate degradant formation rates at the intended storage condition is proposed. This method was compared to traditional shelf life prediction approaches in terms of time required to predict shelf life and associated error in shelf life estimation. Results demonstrated that the proposed LC/MS method using initial rates analysis provided significantly improved confidence intervals for the predicted shelf life and required less overall time and effort to obtain the stability estimation compared to the other methods evaluated. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association.

  15. ANALYSIS OF PROTEIN DIGESTS BY nano- SCX/RP/MSMS WITH pH SALT GRADIENT SCX ELUTION

    EPA Science Inventory

    The objective of this study was to optimize chromatographic parameters for complex peptide mixture analyses using two dimensional nano-LC/MSMS system. It used a strong cation exchange (SCX) and reversed phase chromatography (RP). The SCX solvent system was designed to promote pep...

  16. Dual Wavelength RP-HPLC Method for Simultaneous Determination of Two Antispasmodic Drugs: An Application in Pharmaceutical and Human Serum.

    PubMed

    Hasan, Najmul; Chaiharn, Mathurot; Khan, Sauleha; Khalid, Hira; Sher, Nawab; Siddiqui, Farhan Ahmed; Siddiqui, Muhammad Zain

    2013-01-01

    A reverse phase stability indicating HPLC method for simultaneous determination of two antispasmodic drugs in pharmaceutical parenteral dosage forms (injectable) and in serum has been developed and validated. Mobile phase ingredients consist of Acetonitrile : buffer : sulfuric acid 0.1 M (50 : 50 : 0.3 v/v/v), at flow rate 1.0 mL/min using a Hibar μ Bondapak ODS C18 column monitored at dual wavelength of 266 nm and 205 nm for phloroglucinol and trimethylphloroglucinol, respectively. The drugs were subjected to stress conditions of hydrolysis (oxidation, base, acid, and thermal degradation). Oxidation degraded the molecule drastically while there was not so much significant effect of other stress conditions. The calibration curve was linear with a correlation coefficient of 0.9999 and 0.9992 for PG and TMP, respectively. The drug recoveries fall in the range of 98.56% and 101.24% with 10 pg/mL and 33 pg/mL limit of detection and limit of quantification for both phloroglucinol and trimethylphloroglucinol. The method was validated in accordance with ICH guidelines and was applied successfully to quantify the amount of trimethylphloroglucinol and phloroglucinol in bulk, injectable form and physiological fluid. Forced degradation studies proved the stability indicating abilities of the method.

  17. A Validated Stability Indicating RP-HPLC Method for the Determination of Emtricitabine, Tenofovir Disoproxil Fumarate, Elvitegravir and Cobicistat in Pharmaceutical Dosage Form

    PubMed Central

    Runja, Chinnalalaiah; Ravi Kumar, Pigili; Avanapu, Srinivasa Rao

    2016-01-01

    A new simple, rapid stability indicating assay method has been developed and validated for the determination of emtricitabine, tenofovir disoproxil fumarate, elvitegravir and cobicistat using reverse-phase high-performance liquid chromatography in their pharmaceutical dosage form. The chromatographic separation was performed on an ODS column (250 × 4.6 mm, 5 µm) using mobile phase A (potassium dihydrogen orthophosphate, pH adjusted to 2.5) and mobile phase B (acetonitrile) in the ratio of 55:45% v/v at a flow rate of 1 mL/min. The analytes were detected at 250 nm. The method was found to be linear in the concentration range of 2–12 µg/mL for EMT, 3–18 µg/mL for TNDF, 1.5–9 µg/mL for ELV and COB, with the coefficient value (R2) of >0.9990. The accuracy was measured via recovery studies and found to be acceptable, and the percentage recoveries were found in the range of 99.93–100.08 ± 0.5%. Forced degradation studies were also conducted, and the drugs were subjected to various stress conditions such as acid hydrolysis, base hydrolysis, oxidative, photolytic and thermal degradation. The proposed method was successfully validated and applied for the quantitative estimation of these drugs in both bulk and tablet dosage forms. PMID:26865655

  18. Characterization of aluminum/RP-1 gel propellant properties

    NASA Technical Reports Server (NTRS)

    Rapp, Douglas C.; Zurawski, Robert L.

    1988-01-01

    Research efforts are being conducted by the NASA Lewis Research Center to formulate and characterize the properties of Al/RP-1 and RP-1 gelled propellants for rocket propulsion systems. Twenty four different compositions of gelled fuels were formulated with 5 and 16 micron, atomized aluminum powder in RP-1. The total solids concentration in the propellant varied from 5 to 60 wt percent. Tests were conducted to evaluate the stability and rheological characteristics of the fuels. Physical separation of the solids occurred in fuels with less than 50 wt percent solids concentration. The rheological characteristics of the Al/RP-1 fuels varied with solids concentration. Both thixotropic and rheopectic gel behavior were observed. The unmetallized RP-1 gels, which were formulated by a different technique than the Al/RP-1 gels, were highly viscoelastic. A history of research efforts which were conducted to formulate and characterize the properties of metallized propellants for various applications is also given.

  19. Determination of Antimycin-A in water by liquid chromatographic/mass spectrometry: single-laboratory validation

    USGS Publications Warehouse

    Bernardy, Jeffry A.; Hubert, Terrance D.; Ogorek, Jacob M.; Schmidt, Larry J.

    2013-01-01

    An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples ≥500 ng/L and 4.8 to 17% RSD with samples ≤100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.

  20. Determination of antimycin-A in water by liquid chromatographic/mass spectrometry: single-laboratory validation.

    PubMed

    Bernardy, Jeffry A; Hubert, Terrance D; Ogorek, Jacob M; Schmidt, Larry J

    2013-01-01

    An LC/MS method was developed and validated for the quantitative determination and confirmation of antimycin-A (ANT-A) in water from lakes or streams. Three different water sample volumes (25, 50, and 250 mL) were evaluated. ANT-A was stabilized in the field by immediately extracting it from water into anhydrous acetone using SPE. The stabilized concentrated samples were then transported to a laboratory and analyzed by LC/MS using negative electrospray ionization. The method was determined to have adequate accuracy (78 to 113% recovery), precision (0.77 to 7.5% RSD with samples > or = 500 ng/L and 4.8 to 17% RSD with samples < or = 100 ng/L), linearity, and robustness over an LOQ range from 8 to 51 600 ng/L.

  1. Confirmatory analysis of 17beta-boldenone, 17alpha-boldenone and androsta-1,4-diene-3,17-dione in bovine urine by liquid chromatography-tandem mass spectrometry.

    PubMed

    Draisci, Rosa; Palleschi, Luca; Ferretti, Emanuele; Lucentini, Luca; delli Quadri, Fernanda

    2003-06-15

    A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for confirmatory analysis of 17beta-boldenone (17beta-BOL), 17alpha-boldenone (17alpha-BOL) and androsta-1,4-diene-3,17-dione (ADD) in bovine urine was developed. [2H(2)]17beta-Testosterone (17beta-T-d(2)) was used as the internal standard. Sample preparation involved enzymatic hydrolysis and purification on a C(18) solid-phase extraction column. Chromatographic separation of the analytes was obtained using an RP-C(18) HPLC column. LC-MS-MS detection was carried out with an atmospheric pressure chemical ionisation (APCI) source equipped with a heated nebulizer (HN) interface operating in the positive ion mode. For unambiguous hormone confirmation, three analyte precursor-product ion combinations were monitored during multiple-reaction monitoring (MRM) LC-MS-MS analysis. Overall recovery (%), repeatability (relative standard deviations, RSD, %) and within-laboratory reproducibility (RSD, %) ranged from 92.2 to 97.7%, from 6.50 to 2.94% and from 13.50 to 5.04%, respectively, for all analytes. The limit of quantification in bovine urine was 0.20 ng ml(-1) for 17beta-BOL and ADD and 0.50 ng ml(-1) for 17alpha-BOL. The validated method was successfully applied for determination of 17beta-BOL, 17alpha-BOL and ADD in a large number of bovine urine samples collected within the national Official Residue Control Program.

  2. Characterization, thermal stability studies, and analytical method development of Paromomycin for formulation development.

    PubMed

    Khan, Wahid; Kumar, Neeraj

    2011-06-01

    Paromomycin (PM) is an aminoglycoside antibiotic, first isolated in the 1950s, and approved in 2006 for treatment of visceral leishmaniasis. Although isolated six decades back, sufficient information essential for development of pharmaceutical formulation is not available for PM. The purpose of this paper was to determine thermal stability and development of new analytical method for formulation development of PM. PM was characterized by thermoanalytical (DSC, TGA, and HSM) and by spectroscopic (FTIR) techniques and these techniques were used to establish thermal stability of PM after heating PM at 100, 110, 120, and 130 °C for 24 h. Biological activity of these heated samples was also determined by microbiological assay. Subsequently, a simple, rapid and sensitive RP-HPLC method for quantitative determination of PM was developed using pre-column derivatization with 9-fluorenylmethyl chloroformate. The developed method was applied to estimate PM quantitatively in two parenteral dosage forms. PM was successfully characterized by various stated techniques. These techniques indicated stability of PM for heating up to 120 °C for 24 h, but when heated at 130 °C, PM is liable to degradation. This degradation is also observed in microbiological assay where PM lost ∼30% of its biological activity when heated at 130 °C for 24 h. New analytical method was developed for PM in the concentration range of 25-200 ng/ml with intra-day and inter-day variability of < 2%RSD. Characterization techniques were established and stability of PM was determined successfully. Developed analytical method was found sensitive, accurate, and precise for quantification of PM. Copyright © 2010 John Wiley & Sons, Ltd. Copyright © 2010 John Wiley & Sons, Ltd.

  3. Development and Validation of Eco-Friendly Liquid Chromatographic and Spectrophotometric Methods for Simultaneous Determination of Coformulated Drugs: Phenylephrine Hydrochloride and Prednisolone Acetate.

    PubMed

    Mostafa, Nadia M; Elsayed, Ghada M; Hassan, Nagiba Y; El Mously, Dina A

    2017-11-01

    Five simple, sensitive, and eco-friendly LC and UV spectrophotometric methods have been developed for the simultaneous determination of phenylephrine hydrochloride (PHE) and prednisolone acetate (PRD) in their combined dosage form. The first method was reversed-phase (RP) LC using methanol-water-heptane-1-sulfonic acid sodium salt (75 + 25 + 0.1, v/v/w) as a mobile phase. Separation was achieved using an XSelect HSS reversed-phase C18 analytical column (250 × 4.6 mm, 5µm). The flow rate was 1.0 mL/min and UV detection was done at 230 nm. Quantification was achieved over the concentration ranges of 5-50 µg/mL for PHE and 2-90 µg/mL for PRD. Four spectrophotometric methods were proposed, namely dual wavelength, first derivative of ratio spectra, ratio difference, and mean-centering of ratio spectra. Linearity was observed in the concentration ranges of 10-120 and 5-35 µg/mL for PHE and PRD, respectively, for the spectrophotometric methods. Green solvents were used in the proposed methods because they play a vital role in the analytical methods' influence on the environment. The suggested methods were validated regarding linearity, accuracy, and precision according to the International Conference on Harmonization guidelines, with satisfactory results. These methods could be used as harmless substitutes for routine analysis of the mentioned drugs, with no interference from excipients.

  4. Preparation of a silica stationary phase co-functionalized with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography.

    PubMed

    Li, Hengye; Zhang, Xuemeng; Zhang, Lin; Wang, Xiaojin; Kong, Fenying; Fan, Dahe; Li, Lei; Wang, Wei

    2017-04-15

    A silica stationary phase was designed and synthesized through the co-functionalization of silica with Wulff-type phenylboronate and C12 for mixed-mode liquid chromatography applications. The as-synthesized stationary phase was characterized by elemental analysis and Fourier Transform-InfraRed Spectroscopy (FT-IR). Retention mechanisms, including boronate affinity (BA), reversed-phase (RP) and anion-exchange (AE), were involved. Retention mechanism switching was easily realized by adjustment of the mobile phase constitution. Cis-diol compounds could be selectively captured under neutral conditions in BA mode and off-line separated in RP mode. Neutral, basic, acidic and amphiprotic compounds were chromatographed on the column in RP chromatography, while inorganic anions were chromatographed in AE chromatography to characterize the mixed-mode nature of the prepared stationary phase. In addition, the RP performance was compared with an octadecyl silica column in terms of column efficiency (N/m), asymmetry factor (A f ), retention factor (k) and resolution (Rs). The prepared stationary phase offered multiple interactions with analytes in addition to hydrophobic interactions under RP elution conditions. Based on the mixed-mode properties, off-line 2D-LC, for selective capture and separation of urinary nucleosides, was successfully realized on a single column, demonstrating its powerful application potential for complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Determination of flumazenil in serum by liquid chromatography-mass spectrometry: Application to kinetics study in acute diazepam overdose.

    PubMed

    Djordjević, Snezana; Jović-Stosić, Jasmina; Kilibarda, Vesna; Segrt, Zoran; Perković-Vukcević, Natasa

    2016-02-01

    Flumazenil is benzodiazepine receptor antagonist. It has been studied for a various indications, including reversal of sedation after surgery or diagnostic procedures, awakening of comatose patients in benzodiazepine overdose, or for symptomatic treatment of hepatic encephalopathy. Some drugs, like theophylline, may prolong its elimination half-life. Considering the long half-life of diazepam and its metabolites, concomitant use of theophylline may reduce the need for repeated dosing of flumazenil in patients with acute diazepam poisoning. The aim of this study was to introduce a reliable and accurate method for determining the concentration of flumazenil after therapeutic application in patients with acute poisoning, and using that method to assess whether the kinetics of flumazenil change in the presence of aminophylline (combination of theophylline and ethylenediamine in a 2:1 ratio) applied as concomitant therapy. Blood samples from patients with acute diazepam poisoning that received flumazenil at the dose of 0.5 mg, or the same dose with 3 mg/kg of body weight of aminophylline, were collected 1, 3, 10, 30, 60, 120 and 240 min after its intravenous administration. Samples were prepared by solid-phase extraction on Oasis HLB cartridges with ethylacetate as extracting agens. Flumazenil was determined by liquid chromatography with mass spectrometry (LC-MS) in single ionmonitoring mode at m/z 304. Separation of flumazenil from matrix compound was performed on Lichrospher RP-8 column usingthe mixture of acidic acetonitrile and 20 mM of ammonium acetatein water (55 : 45) as a mobile phase. The applied analitycal method showed excellent recovery (94.65%). The obtained extracts were much cleaner than the extracts obtained by the sameextractant in the process of liquid-liquid extraction. The limit ofdetection of the LC-MS method described in this paper was 0.5 ng/mL and the limit of quantitation was 1 ng/mL. In the patientstreated with both flumazenil and aminophylline, the eliminationconstant for flumazenil was significantly lower and the elimination half-life was longer (p < 0.05) in comparison with the same parameters in.the patients who received flumazenil alone. The applied LC-MS method for the determination of flumazenil in serum samples of patients with acute diazepam poisoning is rapid, sensitive, precise and specific. Concomitant use with theophylline significantly prolonged elimination of flumazenil during the treatment of acute poisonings with diazepam.

  6. An application of the LC-LSTM framework to the self-esteem instability case.

    PubMed

    Alessandri, Guido; Vecchione, Michele; Donnellan, Brent M; Tisak, John

    2013-10-01

    The present research evaluates the stability of self-esteem as assessed by a daily version of the Rosenberg (Society and the adolescent self-image, Princeton University Press, Princeton, 1965) general self-esteem scale (RGSE). The scale was administered to 391 undergraduates for five consecutive days. The longitudinal data were analyzed using the integrated LC-LSTM framework that allowed us to evaluate: (1) the measurement invariance of the RGSE, (2) its stability and change across the 5-day assessment period, (3) the amount of variance attributable to stable and transitory latent factors, and (4) the criterion-related validity of these factors. Results provided evidence for measurement invariance, mean-level stability, and rank-order stability of daily self-esteem. Latent state-trait analyses revealed that variances in scores of the RGSE can be decomposed into six components: stable self-esteem (40 %), ephemeral (or temporal-state) variance (36 %), stable negative method variance (9 %), stable positive method variance (4 %), specific variance (1 %) and random error variance (10 %). Moreover, latent factors associated with daily self-esteem were associated with measures of depression, implicit self-esteem, and grade point average.

  7. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum.

    PubMed

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min(-1) using a Hibar(®) Lichrosorb(®) C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL(-1) and 0.1 to 0.8 ng mL(-1) respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid.

  8. Development, Validation and Application of RP-HPLC Method: Simultaneous Determination of Antihistamine and Preservatives with Paracetamol in Liquid Formulations and Human Serum

    PubMed Central

    Hasan, Najmul; Chaiharn, Mathurot; Toor, Umair Ali; Mirani, Zulfiqar Ali; Sajjad, Ghulam; Sher, Nawab; Aziz, Mubashir; Siddiqui, Farhan Ahmed

    2016-01-01

    In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min-1 using a Hibar® Lichrosorb® C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL-1 and 0.1 to 0.8 ng mL-1 respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid. PMID:27651840

  9. The toxicity evaluation of prepared Lantana camara nano extract against Spodoptera litura (Lepidoptera: Noctuidae)

    NASA Astrophysics Data System (ADS)

    Kasmara, Hikmat; Melanie, Nurfajri, Dea Audia; Hermawan, Wawan; Panatarani, Camellia

    2018-02-01

    Nanotechnology plays an important role in providing opportunities and possibilities for the development of a plant extracts, particularly applied for agriculture using the organic nanoparticles extract as bioinsecticide. This paper reports the extraction of L. camaraas an insecticidal compound applied to control the S. litura larvae which is the main pest for agricultural commodities in Indonesia. The objective of this research is to evaluate the toxicity performance of nano extract to S. litura larvae. The extract was prepared by maceration and evaporation and followed by particles stabilization. The received suspension was characterized using a Particles Size Analyzer (PSA). The performance evaluation was conducted using dye feed method by observing at 24 h and 48 h. The toxicity performance of L. camara nano extract on S. litura larvae was evaluated based on the lethal concentration which was obtained at 50% of 3rd instar larvae S. litura (LC50) and the toxicity level. The larval mortality data was analyzed by probit analysis to obtain LC50 values. The results showed that the LC50 value of L. camara nano extract after 24 h was 16,347 ppm and after 48 h the LC50 value was 3,548 ppm. The smaller LC50 values indicate a stronger toxicity level, in contrast the best toxicity was LC50 after 48 h with the concentration of 3,548 ppm. Referring to toxicity category standard with LC50 pesticide value, the range 0.5-5 g/L is considered as medium toxic category. Toxicity level of L. camara nano extract to S. litura 3,548 ppm or 3,548 mg/L is considered as medium toxic category.

  10. Quantification of vocal fold motion using echography: application to recurrent nerve paralysis detection

    NASA Astrophysics Data System (ADS)

    Cohen, Mike-Ely; Lefort, Muriel; Bergeret-Cassagne, Héloïse; Hachi, Siham; Li, Ang; Russ, Gilles; Lazard, Diane; Menegaux, Fabrice; Leenhardt, Laurence; Trésallet, Christophe; Frouin, Frédérique

    2015-03-01

    Recurrent nerve paralysis (RP) is one of the most frequent complications of thyroid surgery. It reduces vocal fold mobility. Nasal endoscopy, a mini-invasive procedure, is the conventional way to detect RP. We suggest a new approach based on laryngeal ultrasound and a specific data analysis was designed to help with the automated detection of RP. Ten subjects were enrolled for this feasibility study: four controls, three patients with RP and three patients without RP according to nasal endoscopy. The ultrasound protocol was based on a ten seconds B-mode acquisition in a coronal plane during normal breathing. Image processing included three steps: 1) automated detection of two consecutive closing and opening images, corresponding to extreme positions of vocal folds in the sequence of B-mode images, using principal component analysis of the image sequence; 2) positioning of three landmarks and robust tracking of these points using a multi-pyramidal refined optical flow approach; 3) estimation of quantitative parameters indicating left and right fractions of mobility, and motion symmetry. Results provided by automated image processing were compared to those obtained by an expert. Detection of extreme images was accurate; tracking of landmarks was reliable in 80% of cases. Motion symmetry indices showed similar values for controls and patients without RP. Fraction of mobility was reduced in cases of RP. Thus, our CAD system helped in the detection of RP. Laryngeal ultrasound combined with appropriate image processing helped in the diagnosis of recurrent nerve paralysis and could be proposed as a first-line method.

  11. A rapid quantification method for the screening indicator for β-thalassemia with near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Chen, Jiemei; Peng, Lijun; Han, Yun; Yao, Lijun; Zhang, Jing; Pan, Tao

    2018-03-01

    Near-infrared (NIR) spectroscopy combined with chemometrics was applied to rapidly analyse haemoglobin A2 (HbA2) for β-thalassemia screening in human haemolysate samples. The relative content indicator HbA2 was indirectly quantified by simultaneous analysis of two absolute content indicators (Hb and Hb • HbA2). According to the comprehensive prediction effect of the multiple partitioning of calibration and prediction sets, the parameters were optimized to achieve modelling stability, and the preferred models were validated using the samples not involved in modelling. Savitzky-Golay smoothing was firstly used for the spectral pretreatment. The absorbance optimization partial least squares (AO-PLS) was used to eliminate high-absorption wave-bands appropriately. The equidistant combination PLS (EC-PLS) was further used to optimize wavelength models. The selected optimal models were I = 856 nm, N = 16, G = 1 and F = 6 for Hb and I = 988 nm, N = 12, G = 2 and F = 5 for Hb • HbA2. Through independent validation, the root-mean-square errors and correlation coefficients for prediction (RMSEP, RP) were 3.50 g L- 1 and 0.977 for Hb and 0.38 g L- 1 and 0.917 for Hb • HbA2, respectively. The predicted values of relative percentage HbA2 were further calculated, and the calculated RMSEP and RP were 0.31% and 0.965, respectively. The sensitivity and specificity for β-thalassemia both reached 100%. Therefore, the prediction of HbA2 achieved high accuracy for distinguishing β-thalassemia. The local optimal models for single parameter and the optimal equivalent model sets were proposed, providing more models to match possible constraints in practical applications. The NIR analysis method for the screening indicator of β-thalassemia was successfully established. The proposed method was rapid, simple and promising for thalassemia screening in a large population.

  12. Removal of a C-terminal serine residue proximal to the inter-chain disulfide bond of a human IgG1 lambda light chain mediates enhanced antibody stability and antibody dependent cell-mediated cytotoxicity

    PubMed Central

    Shen, Yang; Zeng, Lin; Zhu, Aiping; Blanc, Tim; Patel, Dipa; Pennello, Anthony; Bari, Amtul; Ng, Stanley; Persaud, Kris; Kang, Yun (Kenneth); Balderes, Paul; Surguladze, David; Hindi, Sagit; Zhou, Qinwei; Ludwig, Dale L.; Snavely, Marshall

    2013-01-01

    Optimization of biophysical properties is a critical success factor for the developability of monoclonal antibodies with potential therapeutic applications. The inter-domain disulfide bond between light chain (Lc) and heavy chain (Hc) in human IgG1 lends structural support for antibody scaffold stability, optimal antigen binding, and normal Fc function. Recently, human IgG1λ has been suggested to exhibit significantly greater susceptibility to reduction of the inter Lc-Hc disulfide bond relative to the same disulfide bond in human IgG1κ. To understand the molecular basis for this observed difference in stability, the sequence and structure of human IgG1λ and human IgG1κ were compared. Based on this Lc comparison, three single mutations were made in the λ Lc proximal to the cysteine residue, which forms a disulfide bond with the Hc. We determined that deletion of S214 (dS) improved resistance of the association between Lc and Hc to thermal stress. In addition, deletion of this terminal serine from the Lc of IgG1λ provided further benefit, including an increase in stability at elevated pH, increased yield from transient transfection, and improved in vitro antibody dependent cell-mediated cytotoxicity (ADCC). These observations support the conclusion that the presence of the terminal serine of the λ Lc creates a weaker inter-chain disulfide bond between the Lc and Hc, leading to slightly reduced stability and a potential compromise in IgG1λ function. Our data from a human IgG1λ provide a basis for further investigation of the effects of deleting terminal serine from λLc on the stability and function of other human IgG1λ antibodies. PMID:23567210

  13. Determination of isoorientin levels in rat plasma after oral administration of Vaccinum bracteatum Thunb. methanol extract by high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Kim, Min-Ji; Kwon, Seung-Hwan; Jang, Choon-Gon; Maeng, Han-Joo

    2018-01-15

    A simple, sensitive and rapid liquid chromatography tandem mass spectrometry method (LC-MS/MS) was developed and validated for the determination of plasma isoorientin levels in rats. After simple protein precipitation using methanol, chromatographic analysis was performed using a Synergi 4μ polar-RP 80A column (150 × 2.0 mm, 4μm) under isocratic conditions and a mobile phase consisting of 0.1% formic acid in water and methanol (80:20, v/v) at a flow rate of 0.2 mL/min. In positive electrospray ionization mode, the protonated precursor and product ion transitions of isoorientin (m/z 449.0 → 299.1) and of puerarin (the internal standard; m/z 417.1 → 297.1) were acquired by multiple reaction monitoring. Calibration curves obtained for plasma showed good linearity over the concentration range 1-1000 ng/mL. The lower limit of quantification was 1 ng/mL. Intra- and inter-day precisions were within 8.8% relative standard deviation. Accuracies ranged from 92.1 and 109.7%. The isoorientin stability in rat plasma under typical handling/storage conditions also found to be acceptable. The developed method was applied successfully to a pharmacokinetic study of isoorientin orally administered as the methanol extract of Vaccinium bracteatum Thunb. or administered as pure isoorientin. Copyright © 2018 John Wiley & Sons, Ltd.

  14. Analysis of 16 phthalic acid esters in food simulants from plastic food contact materials by LC-ESI-MS/MS.

    PubMed

    Li, Xiaojing; Xiong, Wenming; Lin, Hua; Zhuo, Liyang; Lv, Shuiyuan; Tang, Xi; Chen, Minshi; Zou, Zhexiang; Lin, Zhenyu; Qiu, Bin; Chen, Guonan

    2013-02-01

    An RP LC-ESI-MS/MS method for the determination of the migration of 16 primary phthalic acid esters from plastic samples has been developed using distilled water, 3% acetic acid, 10% alcohol, and olive oil as food simulants. Detection limits were 1.6-18.5 μg/kg in distilled water, 1.4-17.3 μg/kg in 3% acetic acid, 1.4-19.2 μg/kg in 10% alcohol, and 31.9-390.8 μg/kg in olive oil. The RSDs were in the range of 0.07-11.28%. The real plastic products inspection showed that only few analyzed samples were phthalates contaminated. Bis-2-ethylhexyl ester and dibutyl phthalate were the common items migrated from the plastic products into food and feeds, but the migration concentrations were far below the limits set by European Union (1.5 mg/kg for bis-2-ethylhexyl ester and 0.3 mg/kg for dibutyl phthalate). © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Facile quantitation of free thiols in a recombinant monoclonal antibody by reversed-phase high performance liquid chromatography with hydrophobicity-tailored thiol derivatization.

    PubMed

    Welch, Leslie; Dong, Xiao; Hewitt, Daniel; Irwin, Michelle; McCarty, Luke; Tsai, Christina; Baginski, Tomasz

    2018-06-02

    Free thiol content, and its consistency, is one of the product quality attributes of interest during technical development of manufactured recombinant monoclonal antibodies (mAbs). We describe a new, mid/high-throughput reversed-phase-high performance liquid chromatography (RP-HPLC) method coupled with derivatization of free thiols, for the determination of total free thiol content in an E. coli-expressed therapeutic monovalent monoclonal antibody mAb1. Initial selection of the derivatization reagent used an hydrophobicity-tailored approach. Maleimide-based thiol-reactive reagents with varying degrees of hydrophobicity were assessed to identify and select one that provided adequate chromatographic resolution and robust quantitation of free thiol-containing mAb1 forms. The method relies on covalent derivatization of free thiols in denatured mAb1 with N-tert-butylmaleimide (NtBM) label, followed by RP-HPLC separation with UV-based quantitation of native (disulfide containing) and labeled (free thiol containing) forms. The method demonstrated good specificity, precision, linearity, accuracy and robustness. Accuracy of the method, for samples with a wide range of free thiol content, was demonstrated using admixtures as well as by comparison to an orthogonal LC-MS peptide mapping method with isotope tagging of free thiols. The developed method has a facile workflow which fits well into both R&D characterization and quality control (QC) testing environments. The hydrophobicity-tailored approach to the selection of free thiol derivatization reagent is easily applied to the rapid development of free thiol quantitation methods for full-length recombinant antibodies. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Real-time monitoring of process parameters in rice wine fermentation by a portable spectral analytical system combined with multivariate analysis.

    PubMed

    Ouyang, Qin; Zhao, Jiewen; Pan, Wenxiu; Chen, Quansheng

    2016-01-01

    A portable and low-cost spectral analytical system was developed and used to monitor real-time process parameters, i.e. total sugar content (TSC), alcohol content (AC) and pH during rice wine fermentation. Various partial least square (PLS) algorithms were implemented to construct models. The performance of a model was evaluated by the correlation coefficient (Rp) and the root mean square error (RMSEP) in the prediction set. Among the models used, the synergy interval PLS (Si-PLS) was found to be superior. The optimal performance by the Si-PLS model for the TSC was Rp = 0.8694, RMSEP = 0.438; the AC was Rp = 0.8097, RMSEP = 0.617; and the pH was Rp = 0.9039, RMSEP = 0.0805. The stability and reliability of the system, as well as the optimal models, were verified using coefficients of variation, most of which were found to be less than 5%. The results suggest this portable system is a promising tool that could be used as an alternative method for rapid monitoring of process parameters during rice wine fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Cloning of a novel thermostable glucoamylase from thermophilic fungus Rhizomucor pusillus and high-level co-expression with α-amylase in Pichia pastoris.

    PubMed

    He, Zhenggui; Zhang, Lujia; Mao, Youzhi; Gu, Jingchao; Pan, Qi; Zhou, Sixing; Gao, Bei; Wei, Dongzhi

    2014-12-24

    Fungal amylase, mainly constitute of fungal α-amylase and glucoamylase, are utilized in a broad range of industries, such as starch hydrolysis, food and brewing. Although various amylases have been found in fungi, the amylases from Aspergillus dominate the commercial application. One of main problems exist with regard to these commercial use of amylases is relatively low thermal and acid stability. In order to maximize the efficiency of starch process, developing fungal amylases with increased thermostability and acid stability has been attracting researchers' interest continually. Besides, synergetic action of glucoamylase and α-amylase could facilitate the degradation of starch. And co-expressing glucoamylase with α-amylase in one host could avoid the need to ferment repeatedly and improves cost-effectiveness of the process. A novel fungal glucoamylase (RpGla) gene encoding a putative protein of 512 amino acid residues was cloned from Rhizomucor pusillus. BLAST analysis revealed that RpGla shared highest identity of 51% with the Rhizopus oryzae glucoamylase (ABB77799.1). The fungal glucoamylase RpGla was expressed in Pichia pastoris (KM71/9KGla) with maximum activity of 1237 U ml(-1). The optimum pH and temperature of RpGla were pH 4.0 and 70 °C, respectively. Fungal α-amylase (RpAmy) gene was also cloned from R. pusillus and transformed into KM71/9KGla, resulted in recombinant yeast KM71/9KGla-ZαAmy harboring the RpGla and RpAmy genes simultaneously. The maximum saccharogenic activity of KM71/9KGla-ZαAmy was 2218 U ml(-1), which improved 79% compared to KM71/9KGla. Soluble starch hydrolyzed by purified RpGla achieved 43% glucose and 34% maltose. Higher productivity was achieved with a final yield of 48% glucose and 47% maltose catalyzed by purified enzyme preparation produced by KM71/9KGla-ZαAmy. A novel fungal glucoamylase and fungal α-amylase genes were cloned from Rhizomucor pusillus. The two enzymes showed good thermostability and acid stability, and similar biochemical properties facilitated synergetic action of the two enzymes. A dramatic improvement was seen in amylase activity through co-expressing RpGla with RpAmy in Pichia pastoris. This is the first report of improving activity through co-expression glucoamylase with α-amylase in P. pastoris. Besides, fungal glucoamylase and α-amylase from R. pusillus were shown as promising candidates for further application in starch hydrolysis.

  18. Peanut digestome: Identification of digestion resistant IgE binding peptides.

    PubMed

    Di Stasio, Luigia; Picariello, Gianluca; Mongiello, Mariantonietta; Nocerino, Rita; Berni Canani, Roberto; Bavaro, Simona; Monaci, Linda; Ferranti, Pasquale; Mamone, Gianfranco

    2017-09-01

    Stability to proteolytic degradation in the digestive tract is considered a general feature shared by most food allergens. Current digestibility models exclusively utilize purified allergen proteins, neglecting the relevant effects of matrix that occur for foodstuff systems. In the present study, we investigated digestion stability of the major peanut allergens directly in the natural matrix using an in vitro static model that simulates the gastrointestinal digestion including the oral, gastric, duodenal and intestinal (brush border membrane enzymes) phases. Immunogenicity was evaluated by Western Blot using N=8 pooled sera of peanut allergic pediatric subjects. Immunoreactive, large-sized and fragments of Ara h 2, Ara h 6 and Ara h 3 survived hydrolysis as assessed by SDS-PAGE. Smaller resistant peptides mainly arising from Ara h 3 and also Ara h 1 were detected and further identified by LC-high resolution-MS/MS. RP-HPLC purification followed by dot-blot analysis and MS/MS-based identification demonstrated that stable IgE-binding peptides derived from Ara h 3. These results provide a more realistic picture of the potentially allergenic determinants of peanuts that survived the human digestion, taking into account the role of the food matrix, which may significantly affect gastrointestinal breakdown of peanut allergens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Chemical stability of oseltamivir in oral solutions.

    PubMed

    Albert, K; Bockshorn, J

    2007-09-01

    The stability of oseltamivir in oral aqueous solutions containing the preservative sodium benzoate was studied by a stability indicating HPLC-method. The separation was achieved on a RP-18 ec column using a gradient of mobile phase A (aqueous solution of 50 mM ammonium acetate) and mobile phase B (60% (v/v) acetonitrile/40% (v/v) mobile phase A). The assay was subsequently validated according to the ICH guideline Q2(R1). The extemporaneously prepared "Oseltamivir Oral Solution 15 mg/ml for Adults or for Children" (NRF 31.2.) according to the German National Formulary ("Neues Rezeptur-Formularium") was stable for 84 days if stored under refrigeration. After storage at 25 degrees C the content of oseltamivir decreased to 98.4%. Considering the toxicological limit of 0.5% of the 5-acetylamino derivative (the so-called isomer I) the solution is stable for 46 days. Oseltamivir was less stable in a solution prepared with potable water instead of purified water. Due to an increasing pH the stability of this solution decreased to 14 days. Furthermore a white precipitate of mainly calcium phosphate was observed. The addition of 0.1% anhydrous citric acid avoided these problems and improved the stability of the solution prepared with potable water to 63 days. Sodium benzoate was stable in all oral solutions tested.

  20. Comparative analysis of native and permethylated human milk oligosaccharides by liquid chromatography coupled to high resolution mass spectrometry.

    PubMed

    Oursel, Stéphanie; Cholet, Sophie; Junot, Christophe; Fenaille, François

    2017-12-15

    Human milk oligosaccharides (HMOs) represent the third most abundant components of milk after lactose and lipids. HMOs are indigestible by the suckling infant but can act as prebiotics and have significant biological functions regarding the organism defense against pathogens (such as bacteria or viruses) by preventing interactions with their receptors. Although constituted of only five distinct monosaccharide building blocks, HMOs are highly structurally diverse compounds with many co-existing structural isomers. Here we report the development and comparison of two distinct glycomic platforms based on liquid chromatography coupled to high resolution mass spectrometry (LC-MS) for analyzing HMOs. We have implemented and thoroughly compared the LC-MS of permethylated and native HMOs on reversed phase (RP) and porous graphitic carbon (PGC) columns for their ability to resolve the natural heterogeneity of milk oligosaccharides at the highest sensitivity. Our data essentially underlines the usefulness of analyzing HMOs as permethylated derivatives especially for getting more precise structural information at high sensitivity. For instance, permethylation annihilates gas-phase fucose migration during MS/MS experiments, thus facilitating spectra interpretation and giving access to relevant information regarding oligosaccharide branching and isomer distinction. At the opposite, LC-MS profiling of native HMOs (using PGC) in milk performed best in terms of detected species, while also being much faster in terms of sample preparation. Although less efficient than PGC chromatography, RPLC proved successful for separating pairs of permethylated isomeric HMOs. A key advantage of RP over PGC liquid chromatography is that retention times can be correlated to molecular weights, which can greatly facilitate further HMO identification using retention time prediction. Altogether these data lead us to think that LC-MS analysis of native HMOs (using PGC) can be used as first-line profiling approach while permethylation can be performed afterwards for facilitating structural characterization. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Liquid chromatographic and spectrophotometric determination of diflucortolone valerate and isoconazole nitrate in creams.

    PubMed

    Karacan, Elif; Cağlayan, Mehmet Gokhan; Palabiyik, Ismail Murat; Onur, Feyyaz

    2011-01-01

    A new RP-LC method and two new spectrophotometric methods, principal component regression (PCR) and first derivative spectrophotometry, are proposed for simultaneous determination of diflucortolone valerate (DIF) and isoconazole nitrate (ISO) in cream formulations. An isocratic system consisting of an ACE C18 column and a mobile phase composed of methanol-water (95 + 5, v/v) was used for the optimal chromatographic separation. In PCR, the concentration data matrix was prepared by using synthetic mixtures containing these drugs in methanol-water (3 + 1, v/v). The absorbance data matrix corresponding to the concentration data matrix was obtained by measuring the absorbances at 29 wavelengths in the range of 242-298 nm for DIF and ISO in the zero-order spectra of their combinations. In first derivative spectrophotometry, dA/dlambda values were measured at 247.8 nm for DIF and at 240.2 nm for ISO in first derivative spectra of the solution of DIF and ISO in methanol-water (3 + 1, v/v). The linear ranges were 4.00-48.0 microg/mL for DIF and 50.0-400 microg/mL for ISO in the LC method, and 2.40-40.0 microg/mL for DIF and 60.0-260 microg/mL for ISO in the PCR and first derivative spectrophotometric methods. These methods were validated by analyzing synthetic mixtures. These three methods were successfully applied to two pharmaceutical cream preparations.

  2. ASSESSMENT OF MOLECULAR GENETIC STABILITY BETWEEN LONG-TERM CRYOPRESERVED AND TISSUE CULTURED WASABI (Wasabia japonica) PLANTS.

    PubMed

    Maki, S; Hirai, Y; Niino, T; Matsumoto, T

    2015-01-01

    Maintaining the genetic integrity in long-term tissue cultured and cryopreserved plants is important for the conservation of plant genetic resources. In this study, the genetic stability of cryopreserved wasabi shoot tips stored for 10 years at -150 degree C was visualized using Amplified Fragment Length Polymorphism (AFLP) and Methylation Sensitive Amplified Polymorphism (MSAP). The study included plants derived from cryopreserved shoot tips after 10.5 years storage at -150 degree C (LN10yr), after 2 h storage at -196 degree C (LN2hr), cryopreservation controls (No LN cooling (TC)) and non-treated controls without LN cooling (LC). The donor plants for LN2hr, TC and LC were also maintained in vitro at 20 degree C for the same period. Neither technique detected genetic variations in either control or cryopreserved plants. Some mutations were noted in plants maintained in tissue culture for 10 years. Comparison of genome stability for TC and LN2hr plants showed only a minor change in DNA. However, when comparing the LC and Ln10yr, many differences were found. We conclude that cryopreservation is a superior conservation method compared to tissue culture in maintaining genetic stability for a long-term storage of wasabi germplasm.

  3. Stability of thermostable alkaline protease from Bacillus licheniformis RP1 in commercial solid laundry detergent formulations.

    PubMed

    Sellami-Kamoun, Alya; Haddar, Anissa; Ali, Nedra El-Hadj; Ghorbel-Frikha, Basma; Kanoun, Safia; Nasri, Moncef

    2008-01-01

    The stability of crude extracellular protease produced by Bacillus licheniformis RP1, isolated from polluted water, in various solid laundry detergents was investigated. The enzyme had an optimum pH and temperature at pH 10.0-11.0 and 65-70 degrees C. Enzyme activity was inhibited by PMSF, suggesting that the preparation contains a serine-protease. The alkaline protease showed extreme stability towards non-ionic (5% Tween 20% and 5% Triton X-100) and anionic (0.5% SDS) surfactants, which retained 100% and above 73%, respectively, of its initial activity after preincubation 60 min at 40 degrees C. The RP1 protease showed excellent stability and compatibility with a wide range of commercial solid detergents at temperatures from 40 to 50 degrees C, suggesting its further application in detergent industry. The enzyme retained 95% of its initial activity with Ariel followed by Axion (94%) then Dixan (93.5%) after preincubation 60 min at 40 degrees C in the presence of 7 mg/ml of detergents. In the presence of Nadhif and New Det, the enzyme retained about 83.5% of the original activity. The effects of additives such as maltodextrin, sucrose and PEG 4000 on the stability of the enzyme during spray-drying and during subsequent storage in New Det detergent were also examined. All additives tested enhanced stability of the enzyme.

  4. Rational design of botulinum neurotoxin A1 mutants with improved oxidative stability.

    PubMed

    López de la Paz, Manuela; Scheps, Daniel; Jurk, Marcel; Hofmann, Fred; Frevert, Jürgen

    2018-06-01

    Botulinum neurotoxins (BoNTs) are the most potent toxic proteins to mankind known but applied in low doses trigger a localized muscle paralysis that is beneficial for the therapy of several neurological disorders and aesthetic treatment. The paralytic effect is generated by the enzymatic activity of the light chain (LC) that cleaves specifically one of the SNARE proteins responsible for neurotransmitter exocytosis. The activity of the LC in a BoNT-containing therapeutic can be compromised by denaturing agents present during manufacturing and/or in the cell. Stabilization of the LC by reducing vulnerability towards denaturants would thus be advantageous for the development of BoNT-based therapeutics. In this work, we focused on increasing the stability of LC of BoNT/A1 (LC/A1) towards oxidative stress. We tackled this task by rational design of mutations at cysteine and methionine LC/A1 sites. Designed mutants showed improved oxidative stability in vitro and equipotency to wildtype toxin in vivo. Our results suggest that suitable modification of the catalytic domain can lead to more stable BoNTs without impairing their therapeutic efficacy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Identification of Potent ACE Inhibitory Peptides from Wild Almond Proteins.

    PubMed

    Mirzapour, Mozhgan; Rezaei, Karamatollah; Sentandreu, Miguel Angel

    2017-10-01

    In this study, the production, fractionation, purification and identification of ACE (angiotensin-I-converting enzyme) inhibitory peptides from wild almond (Amygdalus scoparia) proteins were investigated. Wild almond proteins were hydrolyzed using 5 different enzymes (pepsin, trypsin, chymotrypsin, alcalase and flavourzyme) and assayed for their ACE inhibitory activities. The degree of ACE inhibiting activity obtained after hydrolysis was found to be in the following order: alcalase > chymotrypsin > trypsin/pepsin > flavourzyme. The hydrolysates obtained from alcalase (IC 50 = 0.8 mg/mL) were fractionated by sequential ultrafiltration at 10 and 3 kDa cutoff values and the most active fraction (<3 kDa) was further separated using reversed phase high-performance liquid chromatography (RP-HPLC). Peptide sequence identifications were carried out on highly potential fractions obtained from RP-HPLC by means of liquid chromatography coupled to electrospray ionization and tandem mass spectrometry (LC-ESI-MS/MS). Sequencing of ACE inhibitory peptides present in the fraction 26 of RP-HPLC resulted in the identification of 3 peptide sequences (VVNE, VVTR, and VVGVD) not reported previously in the literature. Sequence identification of fractions 40 and 42 from RP-HPLC, which showed the highest ACE inhibitory activities (84.1% and 86.9%, respectively), resulted in the identification of more than 40 potential ACE inhibitory sequences. The results indicate that wild almond protein is a rich source of potential antihypertensive peptides and can be suggested for applications in functional foods and drinks with respect to hindrance and mitigation of hypertension after in vivo assessment. This study has shown the potential of wild almond proteins as good sources for producing ACE-inhibitory active peptides. According to this finding, peptides with higher ACE inhibitory activities could be released during the gastrointestinal digestion and contribute to the health- promoting activities of this natural protein source. © 2017 Institute of Food Technologists®.

  6. Impact of storage conditions on the urinary metabolomics fingerprint.

    PubMed

    Laparre, Jérôme; Kaabia, Zied; Mooney, Mark; Buckley, Tom; Sherry, Mark; Le Bizec, Bruno; Dervilly-Pinel, Gaud

    2017-01-25

    Urine stability during storage is essential in metabolomics to avoid misleading conclusions or erroneous interpretations. Facing the lack of comprehensive studies on urine metabolome stability, the present work performed a follow-up of potential modifications in urinary chemical profile using LC-HRMS on the basis of two parameters: the storage temperature (+4 °C, -20 °C, -80 °C and freeze-dried stored at -80 °C) and the storage duration (5-144 days). Both HILIC and RP chromatographies have been implemented in order to globally monitor the urinary metabolome. Using an original data processing associated to univariate and multivariate data analysis, our study confirms that chemical profiles of urine samples stored at +4 °C are very rapidly modified, as observed for instance for compounds such as:N-acetyl Glycine, Adenosine, 4-Amino benzoic acid, N-Amino diglycine, creatine, glucuronic acid, 3-hydroxy-benzoic acid, pyridoxal, l-pyroglutamic acid, shikimic acid, succinic acid, thymidine, trigonelline and valeryl-carnitine, while it also demonstrates that urine samples stored at -20 °C exhibit a global stability over a long period with no major modifications compared to -80 °C condition. This study is the first to investigate long term stability of urine samples and report potential modifications in the urinary metabolome, using both targeted approach monitoring individually a large number (n > 200) of urinary metabolites and an untargeted strategy enabling assessing for global impact of storage conditions. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. The Translocation Domain of Botulinum Neurotoxin A Moderates the Propensity of the Catalytic Domain to Interact with Membranes at Acidic pH

    PubMed Central

    Araye, Anne; Goudet, Amélie; Barbier, Julien; Pichard, Sylvain; Baron, Bruno; England, Patrick; Pérez, Javier; Zinn-Justin, Sophie; Chenal, Alexandre; Gillet, Daniel

    2016-01-01

    Botulinum neurotoxin A (BoNT/A) is composed of three domains: a catalytic domain (LC), a translocation domain (HN) and a receptor-binding domain (HC). Like most bacterial toxins BoNT/A is an amphitropic protein, produced in a soluble form that is able to interact, penetrate and/or cross a membrane to achieve its toxic function. During intoxication BoNT/A is internalized by the cell by receptor-mediated endocytosis. Then, LC crosses the membrane of the endocytic compartment and reaches the cytosol. This translocation is initiated by the low pH found in this compartment. It has been suggested that LC passes in an unfolded state through a transmembrane passage formed by HN. We report here that acidification induces no major conformational change in either secondary or tertiary structures of LC and HN of BoNT/A in solution. GdnHCl-induced denaturation experiments showed that the stability of LC and HN increases as pH drops, and that HN further stabilizes LC. Unexpectedly we found that LC has a high propensity to interact with and permeabilize anionic lipid bilayers upon acidification without the help of HN. This property is downplayed when LC is linked to HN. HN thus acts as a chaperone for LC by enhancing its stability but also as a moderator of the membrane interaction of LC. PMID:27070312

  8. Analysis Study of Stevioside and Rebaudioside A from Stevia rebaudiana Bertoni by Normal Phase SPE and RP-HPLC

    NASA Astrophysics Data System (ADS)

    Martono, Y.; Rohman, A.; Riyanto, S.; Martono, S.

    2018-04-01

    Solid Phase Extraction (SPE) method using silica as sorbent for stevioside and rebaudiosida A analysis in Stevia rebaudiana Bertoni leaf have not been performed. The aim of this study is to develop SPE method using silica as sorbent for Reverse Phase-High Performance Liquid Chromatography (RP-HPLC) analysis of stevioside and rebaudiosida A in S. rebaudiana leaf. The results of this study indicate that the optimal conditions for normal phase SPE (silica) are conditioned with 3.0 mL of hexane. The sample loading volume is 0.1 mL. Cartridge is eluted with 1.0 mL acetonitrile: water (80: 20, v/v) to separate both analytes. The cartridge is washed with chloroform and water of 0.3 mL respectively. The developed SPE sample preparation method meets the accuracy and precision test and can be used for the analysis of stevioside and rebaudioside A by RP-HPLC.

  9. Microwave-assisted extraction and quantitative LC/ID-MS measurement of total choline and free carnitine in food standard reference materials.

    PubMed

    Phillips, Melissa M; Sander, Lane C

    2012-01-01

    The Stakeholder Panel on Infant Formula and Adult Nutritionals of AOAC INTERNATIONAL has declared both choline and carnitine to be priority nutrients in infant formulas, and ongoing efforts exist to develop or improve Official Methods of Analysis for these nutrients. As a result, matrix-based certified reference materials are needed with assigned values for these compounds. In this work, traditional acid and enzymatic hydrolysis procedures were compared to microwave-assisted acid hydrolysis, and conditions optimized to provide complete sample hydrolysis and recovery of total choline from four food standard reference materials (SRMs): whole milk powder, whole egg powder, infant formula, and soy flour. The extracts were analyzed using LC on a mixed-mode column (simultaneous RP and ion exchange) with isotope dilution-MS detection to achieve simultaneous quantification of total choline and free carnitine. Total choline has been determined in these four food matrixes with excellent precision (0.65 to 2.60%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Free carnitine has been determined in two of these food matrixes with excellent precision (0.69 to 2.19%) and accuracy, as confirmed by use of SRM 1849 Infant/Adult Nutritional Formula as a control material. Limitations in simultaneous determination of total choline and free carnitine resulted from extreme differences in concentration of the two components in egg powder and soy flour (at least three orders of magnitude). Samples required dilution to prevent poor LC peak shape, which caused decreased precision in the determination of low concentrations of free carnitine. Despite this limitation, the described method yields results comparable to current AOAC Official Method 999.14 Choline in Infant Formula, with a decrease of more than 2 h in sample preparation time.

  10. Anterior lens epithelium in cataract patients with retinitis pigmentosa - scanning and transmission electron microscopy study.

    PubMed

    Andjelic, Sofija; Drašlar, Kazimir; Hvala, Anastazija; Hawlina, Marko

    2017-05-01

    In retinitis pigmentosa (RP) patients, relatively minor lens opacity in central part of posterior pole of the lens may cause disproportionate functional symptoms requiring cataract operation. To investigate the possible structural reasons for this opacity development, we studied the structure of the lens epithelium of patients with RP. The anterior lens capsule (aLC: basement membrane and associated lens epithelial cells, LECs) was obtained from cataract surgery and prepared for scanning and transmission electron microscopy (SEM and TEM). Both SEM and TEM show a number of abnormal features in the anterior lens epithelium of cataract patients with RP. The abnormalities appear mainly as holes, thinning and degradation of the epithelium, with the dimensions from <1 μm to more than 50 μm. Other types of holes in size up to 20 μm were seen that may be formed by gradual stretching of the lens epithelium. Another type of abnormalities was cracks that were seen between adjacent LECs, with dimensions 0.1-2 μm × up to 10 μm. Abnormal structural features were observed in the anterior lens epithelium that may cause water influx into the lens. This may lead to clouding along the water clefts leading towards the posterior pole in the RP cataractous lens. We suggest that the lens epithelium has a role in the development of the cataract in patients with RP. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  11. A Stability-Indicating HPLC Method for the Determination of Nitrosylcobalamin (NO-Cbl), a Novel Vitamin B12 Analog.

    PubMed

    Dunphy, Michael J; Sysel, Annette M; Lupica, Joseph A; Griffith, Kristie; Sherrod, Taylor; Bauer, Joseph A

    2014-04-01

    Nitrosylcobalamin (NO-Cbl), a novel vitamin B 12 analog and anti-tumor agent, functions as a biologic 'Trojan horse', utilizing the vitamin B 12 transcobalamin II transport protein and cell surface receptor to specifically target cancer cells. a stability-indicating HPLC method was developed for the detection of NO-Cbl during forced degradation studies. This method utilized an ascentis ® RP-amide (150 mm × 4.6 mm, 5 μm) column at 35 °C with a mobile phase (1.0 mL min -1 ) combining a gradient of methanol and an acetate buffer at pH 6.0. Detection wavelengths of 450 and 254 nm were used to detect corrin and non-corrin-based products, respectively. NO-Cbl, synthesized from hydroxocobalamin and pure nitric oxide gas, was subjected to degradative stress conditions including oxidation, hydrolysis and thermal and radiant energy challenge. The method was validated by assessing linearity, accuracy, precision, detection and quantitation limits and robustness. The method was applied successfully for purity assessment of synthesized NO-Cbl and for the determination of NO-Cbl during kinetic studies in aqueous solution and in solid-state degradation assessments. This HPLC method is suitable for the separation of cobalamins in aqueous and methanolic solutions, for routine detection of NO-Cbl and for purity assessment of synthesized NO-Cbl. additionally, this method has potential application in identification and monitoring of diseases involving altered nitric oxide homeostasis where vitamin B 12 therapy is utilized to scavenge excess nitric oxide, subsequently resulting in the in vivo production of NO-Cbl.

  12. A Stability-Indicating HPLC Method for the Determination of Nitrosylcobalamin (NO-Cbl), a Novel Vitamin B12 Analog

    PubMed Central

    Dunphy, Michael J.; Sysel, Annette M.; Lupica, Joseph A.; Griffith, Kristie; Sherrod, Taylor

    2014-01-01

    Nitrosylcobalamin (NO-Cbl), a novel vitamin B12 analog and anti-tumor agent, functions as a biologic ‘Trojan horse’, utilizing the vitamin B12 transcobalamin II transport protein and cell surface receptor to specifically target cancer cells. a stability-indicating HPLC method was developed for the detection of NO-Cbl during forced degradation studies. This method utilized an ascentis® RP-amide (150 mm × 4.6 mm, 5 μm) column at 35 °C with a mobile phase (1.0 mL min−1) combining a gradient of methanol and an acetate buffer at pH 6.0. Detection wavelengths of 450 and 254 nm were used to detect corrin and non-corrin-based products, respectively. NO-Cbl, synthesized from hydroxocobalamin and pure nitric oxide gas, was subjected to degradative stress conditions including oxidation, hydrolysis and thermal and radiant energy challenge. The method was validated by assessing linearity, accuracy, precision, detection and quantitation limits and robustness. The method was applied successfully for purity assessment of synthesized NO-Cbl and for the determination of NO-Cbl during kinetic studies in aqueous solution and in solid-state degradation assessments. This HPLC method is suitable for the separation of cobalamins in aqueous and methanolic solutions, for routine detection of NO-Cbl and for purity assessment of synthesized NO-Cbl. additionally, this method has potential application in identification and monitoring of diseases involving altered nitric oxide homeostasis where vitamin B12 therapy is utilized to scavenge excess nitric oxide, subsequently resulting in the in vivo production of NO-Cbl. PMID:24855323

  13. Current progress and technical challenges of flexible liquid crystal displays

    NASA Astrophysics Data System (ADS)

    Fujikake, Hideo; Sato, Hiroto

    2009-02-01

    We focused on several technical approaches to flexible liquid crystal (LC) display in this report. We have been developing flexible displays using plastic film substrates based on polymer-dispersed LC technology with molecular alignment control. In our representative devices, molecular-aligned polymer walls keep plastic-substrate gap constant without LC alignment disorder, and aligned polymer networks create monostable switching of fast-response ferroelectric LC (FLC) for grayscale capability. In the fabrication process, a high-viscosity FLC/monomer solution was printed, sandwiched and pressed between plastic substrates. Then the polymer walls and networks were sequentially formed based on photo-polymerization-induced phase separation in the nematic phase by two exposure processes of patterned and uniform ultraviolet light. The two flexible backlight films of direct illumination and light-guide methods using small three-primary-color light-emitting diodes were fabricated to obtain high-visibility display images. The fabricated flexible FLC panels were driven by external transistor arrays, internal organic thin film transistor (TFT) arrays, and poly-Si TFT arrays. We achieved full-color moving-image displays using the flexible FLC panel and the flexible backlight film based on field-sequential-color driving technique. Otherwise, for backlight-free flexible LC displays, flexible reflective devices of twisted guest-host nematic LC and cholesteric LC were discussed with molecular-aligned polymer walls. Singlesubstrate device structure and fabrication method using self-standing polymer-stabilized nematic LC film and polymer ceiling layer were also proposed for obtaining LC devices with excellent flexibility.

  14. Comparative Assessment of the Effect of Hyper-glycosylation on the Pattern and Kinetics of Degradation of Darbepoetin Alfa using a Stability-Indicating Orthogonal Testing Protocol.

    PubMed

    Moenes, Eman M; Al-Ghobashy, Medhat A; Mohamed, Abeer A; Salem, Maissa Y

    2018-01-01

    Darbepoetin alfa (DA); hyper-glycosylated Erythropoietin alfa (EPO) is an essential treatment of anemia in patients with chronic kidney failure and cancer. In this study, DA and EPO were subjected to physicochemical stress factors that might be encountered during production, transport and storage (pH, temperature, agitation, repeated freeze-thaw and oxidation). An orthogonal stability-indicating assay protocol comprised of SE-HPLC, RP-HPLC, ELISA and SDS-PAGE was developed and validated to investigate the effect of further glycosylation of DA on the pattern and kinetics of degradation. Results showed a relatively higher stability and lower tendency to form high molecular weight aggregates in the case of DA when compared to EPO, under equivalent stress conditions. Dimers and aggregates were formed for both drugs across the whole pH range and following incubation at temperatures higher than 2-8°C or repeated freeze/thaw. The same observation was noted upon agitation of standard samples prepared in the formulation buffers at high speed and upon oxidation with hydrogen peroxide. The agreement between SE-HPLC, supported with spectral purity data and ELISA confirmed the specificity of both techniques for the intact drugs. Results of RP-HPLC and SDS-PAGE indicated that dimerization occurred through disulfide and bi-tyrosine covalent bonds in the case of pH and oxidation, respectively. It was evident that aggregation was significantly suppressed upon increasing the glycan size and under any of the studied stress factors loss of the glycan has not been observed. These observations supported with the slow kinetics of degradation confirmed the superiority of glyco-engineering over chemical pegylation to enhance the stability of EPO. Formation of such potentially immunogenic product-related impurities at all tested stress factors confirmed the need for orthogonal testing protocols to investigate the complex pattern of degradation of such sensitive products. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Expression, Purification and Characterization of GMZ2'.10C, a Complex Disulphide-Bonded Fusion Protein Vaccine Candidate against the Asexual and Sexual Life-Stages of the Malaria-Causing Plasmodium falciparum Parasite.

    PubMed

    Mistarz, Ulrik H; Singh, Susheel K; Nguyen, Tam T T N; Roeffen, Will; Yang, Fen; Lissau, Casper; Madsen, Søren M; Vrang, Astrid; Tiendrebeogo, Régis W; Kana, Ikhlaq H; Sauerwein, Robert W; Theisen, Michael; Rand, Kasper D

    2017-09-01

    Production and characterization of a chimeric fusion protein (GMZ2'.10C) which combines epitopes of key malaria parasite antigens: glutamate-rich protein (GLURP), merozoite surface protein 3 (MSP3), and the highly disulphide bonded Pfs48/45 (10C). GMZ2'.10C is a potential candidate for a multi-stage malaria vaccine that targets both transmission and asexual life-cycle stages of the parasite. GMZ2'.10C was produced in Lactococcus lactis and purified using either an immunoaffinity purification (IP) or a conventional purification (CP) method. Protein purity and stability was analysed by RP-HPLC, SEC-HPLC, 2-site ELISA, gel-electrophoresis and Western blotting. Structural characterization (mass analysis, peptide mapping and cysteine connectivity mapping) was performed by LC-MS/MS. CP-GMZ2'.10C resulted in similar purity, yield, structure and stability as compared to IP-GMZ2'.10C. CP-GMZ2'.10C and IP-GMZ2'.10C both elicited a high titer of transmission blocking (TB) antibodies in rodents. The intricate disulphide-bond connectivity of C-terminus Pfs48/45 was analysed by tandem mass spectrometry and was established for GMZ2'.10C and two reference fusion proteins encompassing similar parts of Pfs48/45. GMZ2'.10C, combining GMZ2' and correctly-folded Pfs48/45 can be produced by the Lactoccus lactis P170 based expression system in purity and quality for pharmaceutical development and elicit high level of TB antibodies. The cysteine connectivity for the 10C region of Pfs48/45 was revealed experimentally, providing an important guideline for employing the Pfs48/45 antigen in vaccine design.

  16. Comprehensive two-dimensional liquid chromatography separations of pharmaceutical samples using dual Fused-Core columns in the 2nd dimension.

    PubMed

    Alexander, Anthony J; Ma, Lianjia

    2009-02-27

    This paper focuses on the application of RPLC x RPLC to pharmaceutical analysis and addresses the specific problem of separating co-eluting impurities/degradation products that maybe "hidden" within the peak envelope of the active pharmaceutical ingredient (API) and thus may escape detection by conventional methods. A comprehensive two-dimensional liquid chromatograph (LC x LC) was constructed from commercially available HPLC equipment. This system utilizes two independently configurable 2nd dimension binary pumping systems to deliver independent flow rates, gradient profiles and mobile phase compositions to dual Fused-Core secondary columns. Very fast gradient separations (30s total cycle time) were achieved at ambient temperature without excessive backpressure and without compromising optimal 1st dimension sampling rates. The operation of the interface is demonstrated for the analysis of a 1mg/ml standard mixture containing 0.05% of a minor component. The practicality of using RPLC x RPLC for the analysis of actual co-eluting pharmaceutical degradation products, by exploiting pH-induced changes in selectivity, is also demonstrated using a three component mixture. This mixture (an API, an oxidation product of the API at 1.0%, w/w, and a photo degradant of the API at 0.5%, w/w) was used to assess the stability indicating nature of an established LC method for analysis of the API.

  17. Evaluation of shoulder function in clavicular fracture patients after six surgical procedures based on a network meta-analysis.

    PubMed

    Huang, Shou-Guo; Chen, Bo; Lv, Dong; Zhang, Yong; Nie, Feng-Feng; Li, Wei; Lv, Yao; Zhao, Huan-Li; Liu, Hong-Mei

    2017-01-01

    Purpose Using a network meta-analysis approach, our study aims to develop a ranking of the six surgical procedures, that is, Plate, titanium elastic nail (TEN), tension band wire (TBW), hook plate (HP), reconstruction plate (RP) and Knowles pin, by comparing the post-surgery constant shoulder scores in patients with clavicular fracture (CF). Methods A comprehensive search of electronic scientific literature databases was performed to retrieve publications investigating surgical procedures in CF, with the stringent eligible criteria, and clinical experimental studies of high quality and relevance to our area of interest were selected for network meta-analysis. Statistical analyses were conducted using Stata 12.0. Results A total of 19 studies met our inclusion criteria were eventually enrolled into our network meta-analysis, representing 1164 patients who had undergone surgical procedures for CF (TEN group = 240; Plate group = 164; TBW group  =  180; RP group  =  168; HP group  =  245; Knowles pin group  =  167). The network meta-analysis results revealed that RP significantly improved constant shoulder score in patients with CF when compared with TEN, and the post-operative constant shoulder scores in patients with CF after Plate, TBW, HP, Knowles pin and TEN were similar with no statistically significant differences. The treatment relative ranking of predictive probabilities of constant shoulder scores in patients with CF after surgery revealed the surface under the cumulative ranking curves (SUCRA) value is the highest in RP. Conclusion The current network meta-analysis suggests that RP may be the optimum surgical treatment among six inventions for patients with CF, and it can improve the shoulder score of patients with CF. Implications for Rehabilitation RP improves shoulder joint function after surgical procedure. RP achieves stability with minimal complications after surgery. RP may be the optimum surgical treatment for rehabilitation of patients with CF.

  18. Human papillomavirus-exposed Langerhans cells are activated by stabilized Poly-I:C.

    PubMed

    Da Silva, Diane M; Woodham, Andrew W; Rijkee, Laurie K; Skeate, Joseph G; Taylor, Julia R; Koopman, Maaike E; Brand, Heike E; Wong, Michael K; McKee, Greg M; Salazar, Andres M; Kast, W Martin

    2015-12-01

    Human papillomaviruses (HPV) establish persistent infections because of evolved immune evasion mechanisms, particularly HPV-mediated suppression of the immune functions of Langerhans cells (LC), the antigen presenting cells of the epithelium. Polyinosinic-polycytidilic acid (Poly-I:C) is broadly immunostimulatory with the ability to enhance APC expression of costimulatory molecules and inflammatory cytokines resulting in T cell activation. Here we investigated the activation of primary human LC derived from peripheral blood monocytes after exposure to HPV16 virus like particles followed by treatment with stabilized Poly-I:C compounds (s-Poly-I:C), and their subsequent induction of HPV16-specific T cells. Our results indicate that HPV16 particles alone were incapable of inducing LC activation as demonstrated by the lack of costimulatory molecules, inflammatory cytokines, chemokine-directed migration, and HPV16-specific CD8 + T cells in vitro . Conversely, s-Poly-I:C caused significant upregulation of costimulatory molecules and induction of chemokine-directed migration of LC that were pre-exposed to HPV16. In HLA-A*0201-positive donors, s-Poly-I:C treatment was able to induce CD8 + T cell immune responses against HPV16-derived peptides. Thus, s-Poly-I:C compounds are attractive for translation into therapeutics in which they could potentially mediate clearance of persistent HPV infection.

  19. In situ preparation of multilayer coated capillary column with HKUST-1 for separation of neutral small organic molecules by open tubular capillary electrochromatography.

    PubMed

    Xu, Yin-Yin; Lv, Wen-Juan; Ren, Cui-Ling; Niu, Xiao-Ying; Chen, Hong-Li; Chen, Xing-Guo

    2018-01-12

    The popularity of novel nanoparticles coated capillary column has aroused widespread attention of researchers. Metal organic frameworks (MOFs) with special structure and chemical properties have received great interest in separation sciences. This work presents the investigation of HKUST-1 (Hong Kong University of Science and Technology-1, called Cu 3 (BTC) 2 or MOF-199) nanoparticles as a new type of coating material for capillary electrochromatography. For the first time, three layers coating (3-LC), five layers coating (5-LC), ten layers coating (10-LC), fifteen layers coating (15-LC), twenty layers coating(20-LC) and twenty-five layers coating (25-LC) capillary columns coated with HKUST-1 nanoparticles were synthesized by covalent bond with in situ, layer-by-layer self-assembly approach. The results of scanning electron microscopy (SEM), X-ray diffraction (XRD) and plasma atomic emission spectrometry (ICP-AES) indicated that HKUST-1 was successfully grafted on the inner wall of the capillary. The separating performances of 3-LC, 5-LC, 10-LC, 15-LC, 20-LC and 25-LC open tubular (OT) capillary columns were studied with some neutral small organic molecules. The results indicated that the neutral small organic molecules were separated successfully with 10-LC, 15-LC and 20-LC OT capillary columns because of the size selectivity of lattice aperture and hydrophobicity of organic ligands. In addition, 10-LC and 15-LC OT capillary columns showed better performance for the separation of certain phenolic compounds. Furthermore, 10-LC, 15-LC and 20-LC OT capillary columns exhibited good intra-day repeatability with the relative standard deviations (RSDs; %) of migration time and peak areas lying in the range of 0.3-1.2% and 0.5-4.2%, respectively. For inter-day reproducibility, the RSDs of the three OT capillary columns were found to be lying in the range of 0.3-5.5% and 0.3-4.5% for migration time and peak area, respectively. The RSDs of retention times for column-to-column for three batches of 10-LC, 15-LC and 20-LC OT capillary columns were in the range from 2.3% to 7.2%. Moreover, the fabricated 10-LC, 15-LC and 20-LC OT capillary columns exhibited good repeatability and stability for separation, which could be used successively for more than 120 runs with no observable changes on the separation efficiency. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Complexity in estimation of esomeprazole and its related impurities' stability in various stress conditions in low-dose aspirin and esomeprazole magnesium capsules.

    PubMed

    Reddy, Palavai Sripal; Hotha, Kishore Kumar; Sait, Shakil

    2013-01-01

    A complex, sensitive, and precise high-performance liquid chromatographic method for the profiling of impurities of esomeprazole in low-dose aspirin and esomeprazole capsules has been developed, validated, and used for the determination of impurities in pharmaceutical products. Esomeprazole and its related impurities' development in the presence of aspirin was traditionally difficult due to aspirin's sensitivity to basic conditions and esomeprazole's sensitivity to acidic conditions. When aspirin is under basic, humid, and extreme temperature conditions, it produces salicylic acid and acetic acid moieties. These two byproducts create an acidic environment for the esomeprazole. Due to the volatility and migration phenomenon of the produced acetic acid and salicylic acid from aspirin in the capsule dosage form, esomeprazole's purity, stability, and quantification are affected. The objective of the present research work was to develop a gradient reversed-phase liquid chromatographic method to separate all the degradation products and process-related impurities from the main peak. The impurities were well-separated on a RP8 column (150 mm × 4.6mm, X-terra, RP8, 3.5μm) by the gradient program using a glycine buffer (0.08 M, pH adjusted to 9.0 with 50% NaOH), acetonitrile, and methanol at a flow rate of 1.0 mL min(-1) with detection wavelength at 305 nm and column temperature at 30°C. The developed method was found to be specific, precise, linear, accurate, rugged, and robust. LOQ values for all of the known impurities were below reporting thresholds. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis, and thermal degradation in the presence of aspirin. The developed RP-HPLC method was validated according to the present ICH guidelines for specificity, linearity, accuracy, precision, limit of detection, limit of quantification, ruggedness, and robustness.

  1. Validation of Reference Genes for Quantitative Expression Analysis by Real-Time RT-PCR in Four Lepidopteran Insects

    PubMed Central

    Teng, Xiaolu; Zhang, Zan; He, Guiling; Yang, Liwen; Li, Fei

    2012-01-01

    Quantitative real-time polymerase chain reaction (qPCR) is an efficient and widely used technique to monitor gene expression. Housekeeping genes (HKGs) are often empirically selected as the reference genes for data normalization. However, the suitability of HKGs used as the reference genes has been seldom validated. Here, six HKGs were chosen (actin A3, actin A1, GAPDH, G3PDH, E2F, rp49) in four lepidopteran insects Bombyx mori L. (Lepidoptera: Bombycidae), Plutella xylostella L. (Plutellidae), Chilo suppressalis Walker (Crambidae), and Spodoptera exigua Hübner (Noctuidae) to study their expression stability. The algorithms of geNorm, NormFinder, stability index, and ΔCt analysis were used to evaluate these HKGs. Across different developmental stages, actin A1 was the most stable in P. xylostella and C. suppressalis, but it was the least stable in B. mori and S. exigua. Rp49 and GAPDH were the most stable in B. mori and S. exigua, respectively. In different tissues, GAPDH, E2F, and Rp49 were the most stable in B. mori, S. exigua, and C. suppressalis, respectively. The relative abundances of Siwi genes estimated by 2-ΔΔCt method were tested with different HKGs as the reference gene, proving the importance of internal controls in qPCR data analysis. The results not only presented a list of suitable reference genes in four lepidopteran insects, but also proved that the expression stabilities of HKGs were different among evolutionarily close species. There was no single universal reference gene that could be used in all situations. It is indispensable to validate the expression of HKGs before using them as the internal control in qPCR. PMID:22938136

  2. Validation of reference genes for quantitative expression analysis by real-time rt-PCR in four lepidopteran insects.

    PubMed

    Teng, Xiaolu; Zhang, Zan; He, Guiling; Yang, Liwen; Li, Fei

    2012-01-01

    Quantitative real-time polymerase chain reaction (qPCR) is an efficient and widely used technique to monitor gene expression. Housekeeping genes (HKGs) are often empirically selected as the reference genes for data normalization. However, the suitability of HKGs used as the reference genes has been seldom validated. Here, six HKGs were chosen (actin A3, actin A1, GAPDH, G3PDH, E2F, rp49) in four lepidopteran insects Bombyx mori L. (Lepidoptera: Bombycidae), Plutella xylostella L. (Plutellidae), Chilo suppressalis Walker (Crambidae), and Spodoptera exigua Hübner (Noctuidae) to study their expression stability. The algorithms of geNorm, NormFinder, stability index, and ΔCt analysis were used to evaluate these HKGs. Across different developmental stages, actin A1 was the most stable in P. xylostella and C. suppressalis, but it was the least stable in B. mori and S. exigua. Rp49 and GAPDH were the most stable in B. mori and S. exigua, respectively. In different tissues, GAPDH, E2F, and Rp49 were the most stable in B. mori, S. exigua, and C. suppressalis, respectively. The relative abundances of Siwi genes estimated by 2(-ΔΔCt) method were tested with different HKGs as the reference gene, proving the importance of internal controls in qPCR data analysis. The results not only presented a list of suitable reference genes in four lepidopteran insects, but also proved that the expression stabilities of HKGs were different among evolutionarily close species. There was no single universal reference gene that could be used in all situations. It is indispensable to validate the expression of HKGs before using them as the internal control in qPCR.

  3. Analysis of anti-neoplastic drug in bacterial ghost matrix, w/o/w double nanoemulsion and w/o nanoemulsion by a validated 'green' liquid chromatographic method.

    PubMed

    Youssof, Abdullah M E; Salem-Bekhit, Mounir M; Shakeel, Faiyaz; Alanazi, Fars K; Haq, Nazrul

    2016-07-01

    The objective of the present investigation was to develop and validate a 'green' reversed phase high-performance liquid chromatography (RP-HPLC) method for rapid analysis of a cytotoxic drug 5-fluorouracil (5-FU) in bulk drug, marketed injection, water-in-oil (w/o) nanoemulsion, double water-in-oil-in-water (w/o/w) nanoemulsion and bacterial ghost (BG) matrix. The chromatography study was carried out at room temperature (25±1°C) using an HPLC system with the help of ultraviolet (UV)-visible detector. The chromatographic performance was achieved with a Nucleodur 150mm×4.6mm RP C8 column filled with 5µm filler as a static phase. The mobile phase consisted of ethyl acetate: methanol (7:3% v/v) which was delivered at a flow rate of 1.0mLmin(-1) and the drug was detected in UV mode at 254nm. The developed method was validated in terms of linearity (r(2)=0.998), accuracy (98.19-102.09%), precision (% RSD=0.58-1.17), robustness (% RSD=0.12-0.53) and sensitivity with satisfactory results. The efficiency of the method was demonstrated by the assay of the drug in marketed injection, w/o nanoemulsion, w/o/w nanoemulsion and BG with satisfactory results. The successful resolution of the drug along with its degradation products clearly established the stability-indicating nature of the proposed method. Overall, these results suggested that the proposed analytical method could be effectively applied to the routine analysis of 5-FU in bulk drug, various pharmaceutical dosage forms and BG. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. UPLC and LC-MS studies on degradation behavior of irinotecan hydrochloride and development of a validated stability-indicating ultra-performance liquid chromatographic method for determination of irinotecan hydrochloride and its impurities in pharmaceutical dosage forms.

    PubMed

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Sunil P

    2012-10-01

    The objective of the current investigation was to study the degradation behavior of irinotecan hydrochloride under different International Conference on Harmonization (ICH) recommended stress conditions using ultra-performance liquid chromatography and liquid chromatography-mass spectrometry and to establish a validated stability-indicating reverse-phase ultra-performance liquid chromatographic method for the quantitative determination of irinotecan hydrochloride and its seven impurities and degradation products in pharmaceutical dosage forms. Irinotecan hydrochloride was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Irinotecan hydrochloride was found to degrade significantly in oxidative and base hydrolysis and photolytic degradation conditions. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating power of the method. Chromatographic separation was achieved on a Waters Acquity BEH C8 (100 × 2.1 mm) 1.7-µm column with a mobile phase containing a gradient mixture of solvent A (0.02M KH(2)PO(4) buffer, pH 3.4) and solvent B (a mixture of acetonitrile and methanol in the ratio of 62:38 v/v). The mobile phase was delivered at a flow rate of 0.3 mL/min with ultraviolet detection at 220 nm. The run time was 8 min, within which irinotecan and its seven impurities and degradation products were satisfactorily separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of irinotecan hydrochloride in pharmaceutical dosage forms.

  5. Simultaneous quantitative analysis of main components in linderae reflexae radix with one single marker.

    PubMed

    Wang, Li-Li; Zhang, Yun-Bin; Sun, Xiao-Ya; Chen, Sui-Qing

    2016-05-08

    Establish a quantitative analysis of multi-components by the single marker (QAMS) method for quality evaluation and validate its feasibilities by the simultaneous quantitative assay of four main components in Linderae Reflexae Radix. Four main components of pinostrobin, pinosylvin, pinocembrin, and 3,5-dihydroxy-2-(1- p -mentheneyl)- trans -stilbene were selected as analytes to evaluate the quality by RP-HPLC coupled with a UV-detector. The method was evaluated by a comparison of the quantitative results between the external standard method and QAMS with a different HPLC system. The results showed that no significant differences were found in the quantitative results of the four contents of Linderae Reflexae Radix determined by the external standard method and QAMS (RSD <3%). The contents of four analytes (pinosylvin, pinocembrin, pinostrobin, and Reflexanbene I) in Linderae Reflexae Radix were determined by the single marker of pinosylvin. This fingerprint was the spectra determined by Shimadzu LC-20AT and Waters e2695 HPLC that were equipped with three different columns.

  6. Recovery of soluble proteins from migratory locust (Locusta migratoria) and characterisation of their compositional and techno-functional properties.

    PubMed

    Purschke, Benedict; Tanzmeister, Helene; Meinlschmidt, Pia; Baumgartner, Sabine; Lauter, Kathrin; Jäger, Henry

    2018-04-01

    Edible insects emerged as an alternative source of high-quality proteins. Therefore, the effect of an extraction procedure for the recovery of migratory locust (Locusta migratoria) protein concentrate (MLPC) on the compositional characteristics and techno-functional properties was studied. The influence of pH value (2-10) and salt concentration (0, 1 and 3% w/v) on techno-functional properties was evaluated. Proteins were identified and characterized by RP-HPLC, SDS-PAGE and LC-MS/MS. The initial crude protein content of the whole locusts (65.9% on dry base) could be enhanced to 82.3% (MLPC). Solubility profiles of MLPC showed maximum solubility at pH9 (100%). Promising functionality comparable to egg white protein in terms of emulsifying activity at pH5, foamability at pH3 and 3% NaCl, and foam stability at pH9 were found. Consequently, MLPC offers a nutritious protein source with good functional properties at certain conditions, which could be used as food ingredient in a variety of food systems. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Quantitative structure-toxicity relationship of the aquatic toxicity for various narcotic pollutants using the norm indexes.

    PubMed

    Wang, Qiang; Jia, Qingzhu; Yan, Lihong; Xia, Shuqian; Ma, Peisheng

    2014-08-01

    The aquatic toxicity value of hazardous contaminants plays an important role in the risk assessments of aquatic ecosystems. The following study presents a stable and accurate structure-toxicity relationship model based on the norm indexes for the prediction of toxicity value (log(LC50)) for 190 diverse narcotic pollutants (96 h LC50 data for Poecilia reticulata). Research indicates that this new model is very efficient and provides satisfactory results. The suggested prediction model is evidenced by R(2) (square correlation coefficient) and ARD (average relative difference) values of 0.9376 and 10.45%, respectively, for the training set, and 0.9264 and 13.90% for the testing set. Comparison results with reference models demonstrate that this new method, based on the norm indexes proposed in this work, results in significant improvements, both in accuracy and stability for predicting aquatic toxicity values of narcotic pollutants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Dopamine serotonin stabilizer RP5063: A randomized, double-blind, placebo-controlled multicenter trial of safety and efficacy in exacerbation of schizophrenia or schizoaffective disorder.

    PubMed

    Cantillon, Marc; Prakash, Arul; Alexander, Ajay; Ings, Robert; Sweitzer, Dennis; Bhat, Laxminarayan

    2017-11-01

    The study objectives were to evaluate the efficacy, safety, tolerability, and pharmacokinetics of RP5063 versus placebo. The study was conducted in adults with acute exacerbation of schizophrenia or schizoaffective disorder. This 28-day, multicenter, placebo-controlled, double-blind study randomized 234 subjects to RP5063 15, 30, or 50mg; aripiprazole; or placebo (3:3:3:1:2) once daily. The aripiprazole arm was included solely to show assay sensitivity and was not powered to show efficacy. The primary endpoint was change from baseline to Day 28/EOT (End-of-Treatment) in Positive and Negative Syndrome Scale (PANSS) total score; secondary endpoints included PANSS subscales, improvement ≥1 point on the Clinical Global Impressions-Severity (CGI-S), depression and cognition scales. The primary analysis of PANSS Total showed improvement by a mean (SE) of -20.23 (2.65), -15.42 (2.04), and -19.21 (2.39) in the RP5063 15, 30, and 50mg arms, versus -11.41 (3.45) in the placebo arm. The difference between treatment and placebo reached statistical significance for the 15mg (p=0.021) and 50mg (p=0.016) arms. Improvement with RP5063 was also seen for multiple secondary efficacy outcomes. Discontinuation for any reason was much lower for RP5063 (14%, 25%, 12%) versus placebo (26%) and aripiprazole (35%). The most common treatment-emergent adverse events (TEAE) in the RP5063 groups were insomnia and agitation. There were no significant changes in body weight, electrocardiogram, or incidence of orthostatic hypotension; there was a decrease in blood glucose, lipid profiles, and prolactin levels. In conclusion, the novel dopamine serotonin stabilizer, RP5063 is an efficacious and well-tolerated treatment for acute exacerbation of schizophrenia or schizoaffective disorder. Copyright © 2017. Published by Elsevier B.V.

  9. Symmetricity analysis of time to peak parameter of indocyanine green dynamics

    NASA Astrophysics Data System (ADS)

    An, Yuri; Lee, Jungsul; Choi, Chulhee

    2013-03-01

    We have previously discovered that near-infrared optical imaging of indocyanine green (ICG) signal and analyzing its dynamics can be applied for measurement of blood perfusion rate and detection of Raynaud's phenomenon (RP). Especially, RP is closely associated with abnormal vasomotor responses and can progress to tissue necrosis due to excessively sustained vasoconstriction. Therefore, early detecting of RP is one of important implication to prevent tissue damage from peripheral vascular disorders. In the present study, we propose new analysis and scoring method of symmetricity of Tmax value of left and right extremities. Moreover, this symmetricity analysis can give further information about microvascular insufficiency. For validation of the proposed method, we tested whether the segmental and paired analysis of Tmax value (time-to-peak) of ICG dynamics can be used for sensitive diagnosis of microvascular abnormalities which cannot be detected by conventional methods. From the near-infrared images of diabetes mellitus patients with vascular complications, the trend of asymmetry in Tmax value was observed. We assumed that decreasing local blood perfusion by autonomic nerve dysfunction causes the asymmetric Tmax value of right and left feet. These results collectively indicate that the proposed method can be used as a useful diagnostic tool for RP or other microvascular disorders.

  10. A simple LC/MRM-MS-based method to quantify free linker-payload in antibody-drug conjugate preparations.

    PubMed

    Zmolek, Wesley; Bañas, Stefanie; Barfield, Robyn M; Rabuka, David; Drake, Penelope M

    2016-10-01

    Antibody-drug conjugates represent a growing class of biologic drugs that use the targeted specificity of an antibody to direct the localization of a small molecule drug, often a cytotoxic payload. After conjugation, antibody-drug conjugate preparations typically retain a residual amount of free (unconjugated) linker-payload. Monitoring this free small molecule drug component is important due to the potential for free payload to mediate unintended (off-target) toxicity. We developed a simple RP-HPLC/MRM-MS-based assay that can be rapidly employed to quantify free linker-payload. The method uses low sample volumes and offers an LLOQ of 10nM with 370pg on column. This analytical approach was used to monitor free linker-payload removal during optimization of the tangential flow filtration manufacturing step. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Prolonged exposure to arsenic in UK private water supplies: toenail, hair and drinking water concentrations.

    PubMed

    Middleton, D R S; Watts, M J; Hamilton, E M; Fletcher, T; Leonardi, G S; Close, R M; Exley, K S; Crabbe, H; Polya, D A

    2016-05-18

    Chronic exposure to arsenic (As) in drinking water is an established cause of cancer and other adverse health effects. Arsenic concentrations >10 μg L(-1) were previously measured in 5% of private water supplies (PWS) in Cornwall, UK. The present study investigated prolongued exposure to As by measuring biomarkers in hair and toenail samples from 212 volunteers and repeated measurements of As in drinking water from 127 households served by PWS. Strong positive Pearson correlations (rp = 0.95) indicated stability of water As concentrations over the time period investigated (up to 31 months). Drinking water As concentrations were positively correlated with toenail (rp = 0.53) and hair (rp = 0.38) As concentrations - indicative of prolonged exposure. Analysis of washing procedure solutions provided strong evidence of the effective removal of exogenous As from toenail samples. Significantly higher As concentrations were measured in hair samples from males and smokers and As concentrations in toenails were negatively associated with age. A positive association between seafood consumption and toenail As and a negative association between home-grown vegetable consumption and hair As was observed for volunteers exposed to <1 As μg L(-1) in drinking water. These findings have important implications regarding the interpretation of toenail and hair biomarkers. Substantial variation in biomarker As concentrations remained unaccounted for, with soil and dust exposure as possible explanations.

  12. Genetic and molecular characterization of the maize rp3 rust resistance locus.

    PubMed Central

    Webb, Craig A; Richter, Todd E; Collins, Nicholas C; Nicolas, Marie; Trick, Harold N; Pryor, Tony; Hulbert, Scot H

    2002-01-01

    In maize, the Rp3 gene confers resistance to common rust caused by Puccinia sorghi. Flanking marker analysis of rust-susceptible rp3 variants suggested that most of them arose via unequal crossing over, indicating that rp3 is a complex locus like rp1. The PIC13 probe identifies a nucleotide binding site-leucine-rich repeat (NBS-LRR) gene family that maps to the complex. Rp3 variants show losses of PIC13 family members relative to the resistant parents when probed with PIC13, indicating that the Rp3 gene is a member of this family. Gel blots and sequence analysis suggest that at least 9 family members are at the locus in most Rp3-carrying lines and that at least 5 of these are transcribed in the Rp3-A haplotype. The coding regions of 14 family members, isolated from three different Rp3-carrying haplotypes, had DNA sequence identities from 93 to 99%. Partial sequencing of clones of a BAC contig spanning the rp3 locus in the maize inbred line B73 identified five different PIC13 paralogues in a region of approximately 140 kb. PMID:12242248

  13. Assessment of the LC-2 Prelaunch Fatigue Spectra of the CM-to-SM Flange Weld

    NASA Technical Reports Server (NTRS)

    Dawicke, David S.; Newman, John A.

    2008-01-01

    The pad stay and rollout components of the Ares I-X life cycle can generate cyclic stress oscillations to the vehicle that could initiate and grow fatigue cracks from weld defects. The Ares I-X Project requested that a study be performed to determine if stabilization of the vehicle is required to reduce the stresses that could initiate and grow fatigue cracks at the flange-to-skin weld of the Command Module (CM) and Service Module (SM) interface. A fatigue crack growth analysis was conducted that used loads (LC-2) and stress analyses developed by the Ares I-X Project and utilized material data and analysis methods developed by a critical initial flaw size (CIFS) analysis conducted by NASA Engineering and Safety Center (NESC) for the Upper Stage Simulator (USS) of the Ares I-X vehicle. A full CIFS analysis for the CM-to-SM flange-to-skin weld was not performed because the full flight spectrum was not provided and was not necessary to answer the question posed by the Ares I-X Project. Instead, an approach was developed to determine if the crack growth due to the pad stay and rollout components of the flight spectrum would adversely influence the CIFS. The approach taken used a number of conservative assumptions that eliminated the need for high-fidelity analyses and additional material testing, but still provided a bounding solution for the uncertainties of the problem. The results from this analysis indicate that the LC-2 pad stay and rollout spectrum components would not produce significant fatigue crack growth on the CM-to-SM flange-to-skin weld. Thus, from a fatigue crack growth standpoint, no stabilization is required to reduce the LC-2 pad stay and rollout cyclic stresses on the CM-to-SM flange-to-skin weld.

  14. Rapid prototyping modelling in oral and maxillofacial surgery: A two year retrospective study

    PubMed Central

    Stoor, Patricia; Mesimäki, Karri; Kontio, Risto K.

    2015-01-01

    Background The use of rapid prototyping (RP) models in medicine to construct bony models is increasing. Material and Methods The aim of the study was to evaluate retrospectively the indication for the use of RP models in oral and maxillofacial surgery at Helsinki University Central Hospital during 2009-2010. Also, the used computed tomography (CT) examination – multislice CT (MSCT) or cone beam CT (CBCT) - method was evaluated. Results In total 114 RP models were fabricated for 102 patients. The mean age of the patients at the time of the production of the model was 50.4 years. The indications for the modelling included malignant lesions (29%), secondary reconstruction (25%), prosthodontic treatment (22%), orthognathic surgery or asymmetry (13%), benign lesions (8%), and TMJ disorders (4%). MSCT examination was used in 92 and CBCT examination in 22 cases. Most of the models (75%) were conventional hard tissue models. Models with colored tumour or other structure(s) of interest were ordered in 24%. Two out of the 114 models were soft tissue models. Conclusions The main benefit of the models was in treatment planning and in connection with the production of pre-bent plates or custom made implants. The RP models both facilitate and improve treatment planning and intraoperative efficiency. Key words:Rapid prototyping, radiology, computed tomography, cone beam computed tomography. PMID:26644837

  15. A Rapid Novel HPLC Method for Estimation of Eight Related Compounds in Azilsartan Kamedoxomil and Identification of Degradation Compounds by Using LC-MS.

    PubMed

    Sreenivasulu, J; Venkata Ramana, P; Sampath Kumar Reddy, G; Nagaraju, Ch V S; Thirumalai Rajan, S; Eswaraiah, S

    2015-10-01

    A novel, rapid, specific and stability-indicating reverse-phase high-performance liquid chromatography method was developed for the quantitative determination of related compounds, obtained from two different synthetic routes and degradation products of Azilsartan kamedoxomil (AZL). The method was developed by using a YMC-Pack pro C18 (150 × 4.6 mm, 3 µm) column with a mobile phase containing a gradient mobile phase combination. The eluted compounds were measured at wavelength 220 nm. The developed method run time was 25 min, within which AZL and its eight impurities were well separated with minimum 3.0 resolution. The drug substance was subjected to stress conditions of hydrolysis (acid, base and water), oxidation, photolysis, sunlight, 75% relative humidity and thermal degradation as per International Conference on Harmonization (ICH) prescribed stress conditions to ascertain the stability-indicating power of the method. Significant degradation was observed during acid, base, peroxide, water hydrolysis and 75% relative humidity studies. The mass balance of AZL was close to 100% in all the stress condition. The developed method was validated as per the ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Evaluation of peptide adsorption-controlled liquid chromatography-tandem mass spectrometric (PAC-LC-MS/MS) method for simple and simultaneous quantitation of amyloid β 1-38, 1-40, 1-42 and 1-43 peptides in dog cerebrospinal fluid.

    PubMed

    Goda, Ryoya; Kobayashi, Nobuhiro

    2012-05-01

    To evaluate the usefulness of the peptide adsorption-controlled liquid chromatography-tandem mass spectrometry (PAC-LC-MS/MS) for reproducible measurement of peptides in biological fluids, simultaneous quantitation of amyloid β 1-38, 1-40, 1-42 and 1-43 peptides (Aβ38, Aβ40, Aβ42 and Aβ43) in dog cerebrospinal fluid (CSF) was tried. Each stable isotope labeled Aβ was used as the internal standard to minimize the influence of CSF matrix on the reproducible Aβ quantitation. To reduce a loss of Aβ during the pretreatment procedures, the dog CSF diluted by water-acetic acid-methanol (2:6:1, v/v/v) was loaded on PAC-LC-MS/MS directly. Quantification of the Aβ in the diluted dog CSF was carried out using multiple reaction monitoring (MRM) mode. The [M+5H(5+)] and b(5+) ion fragment of each peptide were chosen as the precursor and product ions for MRM transitions of each peptide. The calibration curves were drawn from Aβ standard calibration solutions using PAC-LC-MS/MS. Analysis of dog CSF samples suggests that the basal concentration of Aβ38, Aβ40, Aβ42 and Aβ43 in dog CSF is approximately 300, 900, 200 and 30 pM, respectively. This is the first time Aβ concentrations in dog CSF have been reported. Additionally, the evaluation of intra- and inter-day reproducibility of analysis of Aβ standard solution, the freeze-thaw stability and the room temperature stability of Aβ standard solution suggest that the PAC-LC-MS/MS method enables reproducible Aβ quantitation. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Comparison of methods, storage conditions, and time to analysis of serum and urine creatinine measured from microsamples by liquid chromatography mass spectrometery (LC/MS) vs. Jaffe.

    PubMed

    Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel

    2014-09-01

    Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; P< 0.001). Similarly, Jaffe measurements showed changes in the mean differences over time; however, these were not significant. UCr values were consistently higher using LC/MS than Jaffe (F = 19; P< 0.01), and UCr changed over time (F = 8.7; P < 0.02). In addition, the interaction term for method and time was also significant (F = 5.8; P < 0.04) which reflects the stability of the Jaffe measurements over time whereas the LC/MS measurements declined; especially after being frozen for 1 year (P < 0.001). UCr measured by Jaffe is lower than samples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.

  18. Preparation and properties of dough-modeling compound/fly ash/reclaim powder composites

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, W.L.

    A novel composite was prepared with reclaim powder (RP) matrix, dough-modeling compound (DMC) reinforcement and fly ash (FA) filler in this article. The compatibility and crosslinking construction of the FA/RP composites were respectively, studied by the polarizing microscope and IR, the optimal formulation and experimental process were determined by measuring the mechanical properties such as shore A hardness, tensile strength, elongation at break, wear resistance and the thermal stability. The results showed that DMC/FA/RP composites exhibited extremely high mechanical and thermal properties when the mass ratio of the DMC/FA/RP composites was 45/25/100, and the cure condition is at 145 {supmore » o}C for 30 min under 9 MPa.« less

  19. Ratio manipulating spectrophotometry versus chemometry as stability indicating methods for cefquinome sulfate determination

    NASA Astrophysics Data System (ADS)

    Yehia, Ali M.; Arafa, Reham M.; Abbas, Samah S.; Amer, Sawsan M.

    2016-01-01

    Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.0-40.0 μg mL- 1. Concentration Residuals Augmented Classical Least Squares was applied and evaluated for the determination of the cited drug in the presence of its all degradation products. Traditional Partial Least Squares regression was also applied and benchmarked against the proposed advanced multivariate calibration. Experimentally designed 25 synthetic mixtures of three factors at five levels were used to calibrate and validate the multivariate models. Advanced chemometrics succeeded in quantitative and qualitative analyses of CFQ along with its hydrolytic, oxidative and photo-degradation products. The proposed methods were applied successfully for different pharmaceutical formulations analyses. These developed methods were simple and cost-effective compared with the manufacturer's RP-HPLC method.

  20. Stability of omega-3 LC-PUFA-rich photoautotrophic microalgal oils compared to commercially available omega-3 LC-PUFA oils.

    PubMed

    Ryckebosch, Eline; Bruneel, Charlotte; Termote-Verhalle, Romina; Lemahieu, Charlotte; Muylaert, Koenraad; Van Durme, Jim; Goiris, Koen; Foubert, Imogen

    2013-10-23

    Microalgae are the primary producers of omega-3 LC-PUFA, which are known for their health benefits. Their oil may thus be a potential alternative for fish oil. However, oxidative and hydrolytic stability of omega-3 LC-PUFA oils are important parameters. The purpose of this work was therefore to evaluate these parameters in oils from photoautotrophic microalgae (Isochrysis, Phaeodactylum, Nannochloropsis gaditana, and Nannochloropsis sp.) obtained with hexane/isopropanol (HI) and hexane (H) and compare them with commercial omega-3 LC-PUFA oils. When the results of both the primary and secondary oxidation parameters were put together, it was clear that fish, tuna, and heterotrophic microalgae oil are the least oxidatively stable oils, whereas krill oil and the microalgae oils performed better. The microalgal HI oils were shown to be more oxidatively stable than the microalgal H oils. The hydrolytic stability was shown not to be a problem during the storage of any of the oils.

  1. Formation of liquid crystalline phases in aqueous suspensions of platelet-like tripalmitin nanoparticles

    NASA Astrophysics Data System (ADS)

    Schmiele, Martin; Gehrer, Simone; Westermann, Martin; Steiniger, Frank; Unruh, Tobias

    2014-06-01

    Suspensions of platelet-like shaped tripalmitin nanocrystals stabilized by the pure lecithin DLPC and the lecithin blend S100, respectively, have been studied by small-angle x-ray scattering (SAXS) and optical observation of their birefringence at different tripalmitin (PPP) concentrations φPPP. It could be demonstrated that the platelets of these potential drug delivery systems start to form a liquid crystalline phase already at pharmaceutically relevant concentrations φPPP of less than 10 wt. %. The details of this liquid crystalline phase are described here for the first time. As in a previous study [A. Illing et al., Pharm. Res. 21, 592 (2004)] some platelets are found to self-assemble into lamellar stacks above a critical tripalmitin concentration \\varphi _{PPP}^{st} of 4 wt. %. In this study another critical concentration \\varphi _{PPP}^{lc}≈ 7 wt. % for DLPC and \\varphi _{PPP}^{lc}≈ 9 wt. % for S100 stabilized dispersions, respectively, has been observed. \\varphi _{PPP}^{lc} describes the transition from a phase of randomly oriented stacked lamellae and remaining non-assembled individual platelets to a phase in which the stacks and non-assembled platelets exhibit an overall preferred orientation. A careful analysis of the experimental data indicates that for concentrations above \\varphi _{PPP}^{lc} the stacked lamellae start to coalesce to rather small liquid crystalline domains of nematically ordered stacks. These liquid crystalline domains can be individually very differently oriented but possess an overall preferred orientation over macroscopic length scales which becomes successively more expressed when further increasing φPPP. The lower critical concentration for the formation of liquid crystalline domains of the DLPC-stabilized suspension compared to \\varphi _{PPP}^{lc} of the S100-stabilized suspension can be explained by a larger aspect ratio of the corresponding tripalmitin platelets. A geometrical model based on the excluded volumes of individual platelets and stacked lamellae has been developed and successfully applied to reproduce the critical volume fractions for both, the onset of stack formation and the appearance of the liquid crystalline phase.

  2. Comparative analysis of Staphylococcus epidermidis strains utilizing quantitative and cell surface shaving proteomics.

    PubMed

    Solis, Nestor; Cain, Joel A; Cordwell, Stuart J

    2016-01-01

    Staphylococcus epidermidis is an opportunistic pathogen that is an emerging risk factor in hospitals worldwide and is often difficult to eradicate as virulent strains produce a protective biofilm matrix. We utilized cell shaving proteomics to profile surface-exposed proteins from two fully genome sequenced S. epidermidis strains: the avirulent, non-biofilm forming ATCC12228 and the virulent, strongly adherent biofilm forming ATCC35984 (RP62A). A false positive control strategy was employed to calculate the probabilities of proteins being truly surface-exposed. A total of 78 surface-exposed proteins were identified, of which only 19 proteins were common to ATCC12228 and RP62A, and which thus represents the core surfaceome. S. epidermidis RP62A displayed additional proteins involved in biofilm formation (cell wall-associated Bhp and intercellular adhesion protein IcaB), surface antigenicity, peptidoglycan biosynthesis and antibiotic resistance. We concurrently profiled whole cell proteomes of the two strains using iTRAQ quantitation and LC-MS/MS. A total of 1610 proteins were confidently identified (representing 64% of the theoretical S. epidermidis proteome). One hundred and ninety one proteins were differentially abundant between strains. Proteins associated with RP62A were clustered into functions including Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR)-mediated defense, sulfate assimilation, antibiotic resistance and biofilm formation. Validation of the sulfate assimilation and cysteine/methionine biosynthesis pathways showed RP62A contained elevated levels (~25% increase) of methionine that are likely linked to biofilm formation. Cell shaving and quantitative proteomics identified proteins associated with a biofilm-forming, virulent strain of S. epidermidis (RP62A). These proteins show RP62A maintains an active CRISPR-mediated defense, as well as heightened antibiotic resistance in comparison to a non-virulent, non-biofilm forming strain. Increased abundances of sulfate assimilation proteins lead to elevated intracellular methionine. Proteins and their exposed peptides identified on the surface of S. epidermidis RP62A may be useful vaccine antigens in clinical settings if administered in at-risk patients prior to surgical implantations. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Quantitative determination of rocuronium in human plasma by liquid chromatography-electrospray ionization mass spectrometry.

    PubMed

    Farenc, C; Enjalbal, C; Sanchez, P; Bressolle, F; Audran, M; Martinez, J; Aubagnac, J L

    2001-02-23

    Liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) was used for the quantification of the neuromuscular blocking agent rocuronium in human plasma. Verapamil was used as internal standard. The samples were subjected to a dichloromethane liquid-liquid extraction after ion pairing of the positively charged ammonium compound with iodide prior to LC-MS. Optimized conditions involved separation on a Symmetry Shield RP-18 column (50 x 2.1 mm, 3.5 microm) using a 15-min gradient from 10 to 90% acetonitrile in water containing 0.1% trifluoroacetic acid at 250 microl/min. Linear detector responses for standards were observed from 25 to 2,000 ng/ml. The extraction recovery averaged 59% for rocuronium and 83% for the internal standard. The limit of quantification (LOQ), using 500 microl of plasma, was 25 ng/ml. Precision ranged from 1.3 to 19% (LOQ), and accuracy was between 92 and 112%. In plasma samples, at 20 and 4 degrees C, rocuronium was stable at physiological pH for 4 h; frozen at -30 degrees C it was stable for at least 75 days. The method was found suitable for the analysis of samples collected during pharmacokinetic investigations in humans.

  4. Quantitative determination of p-aminosalicylic acid and its degradation product m-aminophenol in pellets by ion-pair high-performance liquid chromatography applying the monolithic Chromolith Speedrod RP-18e column.

    PubMed

    Vasbinder, E; Van der Weken, G; Vander Heyden, Y; Baeyens, W R G; Debunne, A; Remon, J P; García-Campaña, A M

    2004-01-01

    An ion-pair high performance liquid chromatographic method was developed for the simultaneous determination of p-aminosalicylic acid (PAS) and its degradation product m-aminophenol (MAP) in a newly developed multiparticular drug delivery system. Owing to the concentration differences of PAS and MAP, acetanilide and sulfanilic acid were used as internal standards, respectively. The separation was performed on a Chromolith SpeedROD RP-18e column, a new packing material consisting of monolithic rods of highly porous silica. The mobile phase composition was of 20 mm phosphate buffer, 20 mm tetrabutylammonium hydrogen sulphate and 16% (v/v) methanol adjusted to pH 6.8, at a flow-rate of 1.0 mL/min, resulting in a run-time of about 6 min. Detection was by UV at 233 nm. The method was validated and proved to be useful for stability testing of the new dosage form. Separation efficiency was compared between the new packing material Chromolith SpeedROD RP-18e and the conventional reversed-phase cartridge LiChroCART 125-4 (5 microm). A robustness test was carried out on both columns and different separation parameters (retention, resolution, run time, temperature) were determined. Copyright 2004 John Wiley & Sons, Ltd.

  5. Three-dimensional plotter technology for fabricating polymeric scaffolds with micro-grooved surfaces.

    PubMed

    Son, JoonGon; Kim, GeunHyung

    2009-01-01

    Various mechanical techniques have been used to fabricate biomedical scaffolds, including rapid prototyping (RP) devices that operate from CAD files of the target feature information. The three-dimensional (3-D) bio-plotter is one RP system that can produce design-based scaffolds with good mechanical properties for mimicking cartilage and bones. However, the scaffolds fabricated by RP have very smooth surfaces, which tend to discourage initial cell attachment. Initial cell attachment, migration, differentiation and proliferation are strongly dependent on the chemical and physical characteristics of the scaffold surface. In this study, we propose a new 3-D plotting method supplemented with a piezoelectric system for fabricating surface-modified scaffolds. The effects of the physically-modified surface on the mechanical and hydrophilic properties were investigated, and the results of cell culturing of chondrocytes indicate that this technique is a feasible new method for fabricating high-quality 3-D polymeric scaffolds.

  6. Synthesis, biophysical properties and biological activity of second generation antisense oligonucleotides containing chiral phosphorothioate linkages

    PubMed Central

    Wan, W. Brad; Migawa, Michael T.; Vasquez, Guillermo; Murray, Heather M.; Nichols, Josh G.; Gaus, Hans; Berdeja, Andres; Lee, Sam; Hart, Christopher E.; Lima, Walt F.; Swayze, Eric E.; Seth, Punit P.

    2014-01-01

    Bicyclic oxazaphospholidine monomers were used to prepare a series of phosphorothioate (PS)-modified gapmer antisense oligonucleotides (ASOs) with control of the chirality of each of the PS linkages within the 10-base gap. The stereoselectivity was determined to be 98% for each coupling. The objective of this work was to study how PS chirality influences biophysical and biological properties of the ASO including binding affinity (Tm), nuclease stability, activity in vitro and in vivo, RNase H activation and cleavage patterns (both human and E. coli) in a gapmer context. Compounds that had nine or more Sp-linkages in the gap were found to be poorly active in vitro, while compounds with uniform Rp-gaps exhibited activity very similar to that of the stereo-random parent ASOs. Conversely, when tested in vivo, the full Rp-gap compound was found to be quickly metabolized resulting in low activity. A total of 31 ASOs were prepared with control of the PS chirally of each linkage within the gap in an attempt to identify favorable Rp/Sp positions. We conclude that a mix of Rp and Sp is required to achieve a balance between good activity and nuclease stability. PMID:25398895

  7. Nanomaterials as stationary phases and supports in liquid chromatography.

    PubMed

    Beeram, Sandya R; Rodriguez, Elliott; Doddavenkatanna, Suresh; Li, Zhao; Pekarek, Allegra; Peev, Darin; Goerl, Kathryn; Trovato, Gianfranco; Hofmann, Tino; Hage, David S

    2017-10-01

    The development of various nanomaterials over the last few decades has led to many applications for these materials in liquid chromatography (LC). This review will look at the types of nanomaterials that have been incorporated into LC systems and the applications that have been explored for such systems. A number of carbon-based nanomaterials and inorganic nanomaterials have been considered for use in LC, ranging from carbon nanotubes, fullerenes and nanodiamonds to metal nanoparticles and nanostructures based on silica, alumina, zirconia and titanium dioxide. Many ways have been described for incorporating these nanomaterials into LC systems. These methods have included covalent immobilization, adsorption, entrapment, and the synthesis or direct development of nanomaterials as part of a chromatographic support. Nanomaterials have been used in many types of LC. These applications have included the reversed-phase, normal-phase, ion-exchange, and affinity modes of LC, as well as related methods such as chiral separations, ion-pair chromatography and hydrophilic interaction liquid chromatography. Both small and large analytes (e.g., dyes, drugs, amino acids, peptides and proteins) have been used to evaluate possible applications for these nanomaterial-based methods. The use of nanomaterials in columns, capillaries and planar chromatography has been considered as part of these efforts. Potential advantages of nanomaterials in these applications have included their good chemical and physical stabilities, the variety of interactions many nanomaterials can have with analytes, and their unique retention properties in some separation formats. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Comparison of the docetaxel concentration in human plasma measured with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and a nanoparticle immunoassay and clinical applications of that assay.

    PubMed

    Geng, Chunmei; Li, Pingli; Chen, Xuwang; Yuan, Guiyan; Guo, Nan; Liu, Huanjun; Zhang, Rui; Guo, Ruichen

    2017-05-23

    To determine the feasibility of using a nanoparticle immunoassay for clinical therapeutic drug monitoring (TDM) of docetaxel concentrations, a sensitive and simple method of liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established to measure the docetaxel concentration in human plasma and the results of LC-MS/MS and the immunoassay were compared. Docetaxel and paclitaxel (the internal standard, or IS) in human plasma were extracted through protein precipitation, separated on a Diamonsil C18 column (150 mm × 4.6 mm, 5 μm), ionized with positive ions, and detected with LC-MS/MS in multi-reaction monitoring (MRM) mode. Plasma samples from 248 cancer patients were assayed with LC-MS/MS and a nanoparticle immunoassay. Data from the samples were analyzed with the statistical software SPSS and the software MedCalc. Results indicated that the calibration curve of the validated method of LC-MS/MS was linear over the range of 10-2,000 ng/mL, with an lowest limit of quantitation (LLOQ) of 10 ng/mL, and the intra- and inter- day precision and accuracy were both < ± 15%. Comparison of the two methods indicated that results of the LC-MS/MS were closely related to those of the nanoparticle immunoassay, with a correlation coefficient (R) of 0.965 and acceptable 95% confidence intervals (CI) of ‒ 231.7-331.1 ng/mL. Overall, the established method of LC-MC/MS and the nanoparticle immunoassay were both suitable for measurement of the docetaxel concentration in human plasma, and the immunoassay was far more cost-effective and better at clinical TDM of docetaxel in clinical practice.

  9. Immunotherapeutic Vaccine as an Alternative Treatment to Overcome Drug-Resistant Ovarian Cancer

    DTIC Science & Technology

    2012-07-01

    2.7. Fractionation of SCX purified peptides by C-18 chromatography TheSCXpurified iTRAQ labeledpeptidemixturewas fractionated by a Dionex C-18 RP... chromatography as described above for the MHC peptides. All the iTRAQ labeled synthetic peptides were analyzed by a Dionex 3000 nano ultimate HPLC (Sunnyvale CA... chromatography and LC-MS/MS. Proteomics 7:4292-302. 15. Pachuk CJ, Ciccarelli RB, Samuel M, Bayer ME, Troutman RD, Zurawski DV, Schauer JI, Higgins TJ

  10. INVESTIGATION OF THE STABILITY OF AN ARSENOSUGAR IN MOUSE CECUM SAMPLES USING IC-ICP-MS AND LC-ESI-MS/MS DETECTION

    EPA Science Inventory

    Arsenosugar exposures occur mainly through seafood and seaweed ingestion, and the major metabolite present in urine is DMA. Understanding the pathway of this conversion is the goal of this ongoing study. Preliminary studies indicated that very little of the arsenosugar degraded...

  11. Stability study of the anticonvulsant enaminone (E118) using HPLC and LC-MS.

    PubMed

    Abdel-Hamid, Mohammed E; Edafiogho, Ivan O; Hamza, Huda M

    2002-01-01

    The stability of the new chemical synthetic enaminone derivative (E118) was investigated using a stability-indicating high-performance liquid chromatography (HPLC) procedure. The examined samples were analyzed using a chiral HSA column and a mobile phase (pH 7.5) containing n-octanoic acid (5 mM), isopropyl alcohol and 100 mM disodium hydrogen phosphate solution (1:9 v/v) at a flow rate of 1 ml min(-1). The developed method was specific, accurate and reproducible. The HPLC chromatograms exhibited well-resolved peaks of E118 and the degradation products at retention times <5 min. The stability of E118 was performed in 0.1 M hydrochloric acid, 0.1 M sodium hydroxide, water/ethanol (1:1) and phosphate buffer (pH approximately 7.5) solutions. E118 was found to undergo fast hydrolysis in 0.1 M hydrochloric acid solution. The decomposition of E118 followed first order kinetics under the experimental conditions. The results confirmed that protonation of the enaminone system in the molecule enhanced the hydrolysis of E118 at degradation rate constant of 0.049 min(-1) and degradation half-life of 14.1 min at 25 degrees C. However, E118 was significantly stable in 0.1 M sodium hydroxide, physiological phosphate buffer (pH 7.5) and ethanol/water (1:1) solutions. The degradation rate constants and degradation half-lives were in the ranges 0.0023-0.0086 h(-1) and 80.6-150.6 h, respectively. Analysis of the acid-induced degraded solution of E118 by liquid chromatography-mass spectrometry (LC-MS) revealed at least two degradation products of E118 at m/z 213.1 and 113.1, respectively.

  12. Silver-plated vitamins: a method of detecting tocopherols and carotenoids in LC/ESI-MS coupling.

    PubMed

    Rentel, C; Strohschein, S; Albert, K; Bayer, E

    1998-10-15

    In LC/MS, nonpolar substances in the majority of cases cannot be ionized by standard electrospray ionization (ESI) because they obviously lack a site for protonation or deprotonation. The ionization of carotenoids and tocopherols can be greatly enhanced by the addition of silver ions. The Ag(+)-carotenoid and Ag(+)-tocopherol adducts thus formed render these substances amenable to MS. alpha-, beta-, gamma-, and delta-tocopherol, alpha-tocopherol acetate, and the various isomers of lycopene and beta-carotene were separated by C30 RP-HPLC and could be identified by online ESI-MS. A mixture of six different carotenoids was analyzed by scanning the mass range from m/z 500 to 800. The mass spectra of the peaks revealed that all carotenoids and most tocopherols were partially oxidized to radical cations. The detection limit for canthaxanthin was approximately 500 fmol while that of beta-carotene was below 300 fmol. An increase in sensitivity in the MRM mode can be attained by monitoring ions formed by loss of elemental silver from the adducts in the CID cell. Dichloromethane extracts of tomato, carrot, and vegetable juices, a vitamin drink, and a commercial infant food product were analyzed by LC/MS. After postcolumn argentation, from the mass-selective extracts of the TIC, the carotenoids and tocopherols present could be identified by their masses and their retention times. For all studies, a silver perchlorate solution with an overall concentration of 50 micrograms/mL was used.

  13. Thermodynamic guiding principles in selective synthesis of strontium iridate Ruddlesden-Popper epitaxial Films

    DOE PAGES

    Nishio, Kazunori; Hwang, Harold Y.; Hikita, Yasuyuki

    2016-03-10

    We demonstrate the selective fabrication of Ruddlesden-Popper (RP) type SrIrO 3, Sr 3Ir 2O 7, and Sr 2IrO 4 epitaxialthin films from a single SrIrO 3 target using pulsed laser deposition(PLD). We identified that the growth conditions stabilizing each phase directly map onto the phase diagram expected from thermodynamic equilibria. This approach allows precise cation stoichiometry control as evidenced by the stabilization of single phase Sr 3Ir 2O 7 for the first time, overcoming the close thermodynamic stability between neighboring RP phases. Furthermore, despite the non-equilibrium nature of PLD, these results highlight the importance of thermodynamic guiding principles to strategicallymore » synthesize the targeted phase in complex oxide thin films.« less

  14. LC-MS/MS assay for the quantitation of the ATR kinase inhibitor VX-970 in human plasma.

    PubMed

    Kiesel, Brian F; Scemama, Jonas; Parise, Robert A; Villaruz, Liza; Iffland, Andre; Doyle, Austin; Ivy, Percy; Chu, Edward; Bakkenist, Christopher J; Beumer, Jan H

    2017-11-30

    DNA damaging chemotherapy and radiation are widely used standard-of-care modalities for the treatment of cancer. Nevertheless, the outcome for many patients remains poor and this may be attributed, at least in part, to highly effective DNA repair mechanisms. Ataxia-telangiectasia mutated and Rad3-related (ATR) is a key regulator of the DNA-damage response (DDR) that orchestrates the repair of damaged replication forks. ATR is a serine/threonine protein kinase and ATR kinase inhibitors potentiate chemotherapy and radiation. The ATR kinase inhibitor VX-970 (NSC 780162) is in clinical development in combination with primary cytotoxic agents and as a monotherapy for tumors harboring specific mutations. We have developed and validated an LC-MS/MS assay for the sensitive, accurate and precise quantitation of VX-970 in human plasma. A dilute-and-shoot method was used to precipitate proteins followed by chromatographic separation with a Phenomenex Polar-RP 80Å (4μm, 50×2mm) column and a gradient acetonitrile-water mobile phase containing 0.1% formic acid from a 50μL sample volume. Detection was achieved using an API 4000 mass spectrometer using electrospray positive ionization mode. The assay was linear from 3 to 5,000ng/mL, proved to be accurate (94.6-104.2%) and precise (<8.4% CV), and fulfilled criteria from the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be a crucial tool in defining the clinical pharmacokinetics and pharmacology of VX-970 as it progresses through clinical development. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Isolation and characterization of gluten protein types from wheat, rye, barley and oats for use as reference materials.

    PubMed

    Schalk, Kathrin; Lexhaller, Barbara; Koehler, Peter; Scherf, Katharina Anne

    2017-01-01

    Gluten proteins from wheat, rye, barley and, in rare cases, oats, are responsible for triggering hypersensitivity reactions such as celiac disease, non-celiac gluten sensitivity and wheat allergy. Well-defined reference materials (RM) are essential for clinical studies, diagnostics, elucidation of disease mechanisms and food analyses to ensure the safety of gluten-free foods. Various RM are currently used, but a thorough characterization of the gluten source, content and composition is often missing. However, this characterization is essential due to the complexity and heterogeneity of gluten to avoid ambiguous results caused by differences in the RM used. A comprehensive strategy to isolate gluten protein fractions and gluten protein types (GPT) from wheat, rye, barley and oat flours was developed to obtain well-defined RM for clinical assays and gluten-free compliance testing. All isolated GPT (ω5-gliadins, ω1,2-gliadins, α-gliadins, γ-gliadins and high- and low-molecular-weight glutenin subunits from wheat, ω-secalins, γ-75k-secalins, γ-40k-secalins and high-molecular-weight secalins from rye, C-hordeins, γ-hordeins, B-hordeins and D-hordeins from barley and avenins from oats) were fully characterized using analytical reversed-phase high-performance liquid chromatography (RP-HPLC), sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), N-terminal sequencing, electrospray-ionization quadrupole time-of-flight mass spectrometry (LC-ESI-QTOF-MS) and untargeted LC-MS/MS of chymotryptic hydrolyzates of the single GPT. Taken together, the analytical methods confirmed that all GPT were reproducibly isolated in high purity from the flours and were suitable to be used as RM, e.g., for calibration of LC-MS/MS methods or enzyme-linked immunosorbent assays (ELISAs).

  16. Development and validation of sensitive LC/MS/MS method for quantitative bioanalysis of levonorgestrel in rat plasma and application to pharmacokinetics study.

    PubMed

    Ananthula, Suryatheja; Janagam, Dileep R; Jamalapuram, Seshulatha; Johnson, James R; Mandrell, Timothy D; Lowe, Tao L

    2015-10-15

    Rapid, sensitive, selective and accurate LC/MS/MS method was developed for quantitative determination of levonorgestrel (LNG) in rat plasma and further validated for specificity, linearity, accuracy, precision, sensitivity, matrix effect, recovery efficiency and stability. Liquid-liquid extraction procedure using hexane:ethyl acetate mixture at 80:20 v:v ratio was employed to efficiently extract LNG from rat plasma. Reversed phase Luna column C18(2) (50×2.0mm i.d., 3μM) installed on a AB SCIEX Triple Quad™ 4500 LC/MS/MS system was used to perform chromatographic separation. LNG was identified within 2min with high specificity. Linear calibration curve was drawn within 0.5-50ng·mL(-1) concentration range. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency at three quality control (QC) concentrations 0.5 (low), 5 (medium) and 50 (high) ng·mL(-1) was found to be >90%. Stability of LNG at various stages of experiment including storage, extraction and analysis was evaluated using QC samples, and the results showed that LNG was stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of LNG in rats after SubQ injection, providing its applicability in relevant preclinical studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Role of FOXO1 in aldosterone-induced autophagy: A compensatory protective mechanism related to podocyte injury

    PubMed Central

    Wang, Bin; Ding, Wei; Zhang, Minmin; Li, Hongmei; Guo, Honglei; Lin, Lilu; Chen, Jing; Gu, Yong

    2016-01-01

    This study was undertaken to elucidate whether and how autophagy was regulated in aldosterone (Aldo)-induced podocyte injury and to examine its role in this model both in vitro and in vivo. In cultured podocytes, Aldo increased autophagy flux as indicated by the enhanced expression of LC3-II/LC3-I and the reduction of p62. Autophagy induction with rapamycin (RP) provided a cytoprotective effect, and inhibition of autophagy with Atg7-specific siRNA, chloroquine (CQ) or 3-methyladenine (3-MA) worsened Aldo-induced podocyte injury by attenuating endoplasmic reticulum (ER) stress. Aldo inhibited Akt phosphorylation but increased the mammalian target of rapamycin (mTOR) signaling pathway; however, Aldo up-regulated the expression of FOXO1 and its downstream effector Rab7. Either knockdown of FOXO1 or Rab7 inhibited Aldo-induced autophagy. Additionally, an elevated level of P300-regulated acetylation of FOXO1 and the interaction of acetylated FOXO1 and Atg7 were also confirmed to be involved in regulating autophagy in Aldo-induced podocytes. Similar results were further confirmed in vivo. We propose that autophagy enhancement through enhancing of the FOXO1/Rab7 axis and post-translational modification of FOXO1 may represent a potential therapeutic strategy against podocyte injury by promoting autophagy. PMID:27244896

  18. Separation and quantification of 15 carotenoids by reversed phase high performance liquid chromatography coupled to diode array detection with isosbestic wavelength approach.

    PubMed

    Mitrowska, Kamila; Vincent, Ursula; von Holst, Christoph

    2012-04-13

    The manuscript presents the development of a new reverse phase high performance liquid chromatography (RP-HPLC) photo diode array detection method allowing the separation and quantification of 15 carotenoids (adonirubin, adonixanthin, astaxanthin, astaxanthin dimethyl disuccinate, asteroidenone, beta-apo-8'-carotenal, beta-apo-8'-carotenoic acid ethyl ester, beta-carotene, canthaxanthin, capsanthin, citranaxanthin, echinenone, lutein, lycopene, and zeaxanthin), 10 of which are feed additives authorised within the European Union. The developed method allows for the reliable determination of the total carotenoid content in one run using the corresponding E-isomer as calibration standard while taking into account the E/Z-isomers composition. This is a key criterion for the application of the method, since for most of the analytes included in this study analytical standards are only available for the E-isomers. This goal was achieved by applying the isosbestic concept, in order to identify specific wavelengths, at which the absorption coefficients are identical for all stereoisomers concerned. The second target referred to the optimisation of the LC conditions. By means of an experimental design, an optimised RP-HPLC method was developed allowing for a sufficient chromatographic separation of all carotenoids. The selected method uses a Suplex pKb-100 HPLC column and applying a gradient with a mixture of acetonitrile, tert-butyl-methyl ether and water as mobile phases. The limits of detection and limits of quantification ranged from 0.06 mg L(-1) to 0.14 mg L(-1) and from 0.20 mg L(-1) to 0.48 mg L(-1), respectively. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Electrochemical behavior and pH stability of artificial salivas for corrosion tests.

    PubMed

    Queiroz, Gláucia Maria Oliveira de; Silva, Leandro Freitas; Ferreira, José Tarcísio Lima; Gomes, José Antônio da Cunha P; Sathler, Lúcio

    2007-01-01

    It is assumed that the compositions of artificial salivas are similar to that of human saliva. However, the use of solutions with different compositions in in vitro corrosion studies can lead dissimilar electrolytes to exhibit dissimilar corrosivity and electrochemical stability. This study evaluated four artificial salivas as regards pH stability with time, redox potentials and the polarization response of an inert platinum electrode. The tested solutions were: SAGF medium, Mondelli artificial saliva, UFRJ artificial saliva (prepared at the School of Pharmacy, Federal University of Rio de Janeiro, RJ, Brazil) and USP-RP artificial saliva (prepared at the School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, SP, Brazil). It was observed that pH variations were less than 1 unit during a 50-hour test. The SAGF medium, and the UFRJ and USP-RP solutions exhibited more oxidizing characteristics, whereas the Mondelli solution presented reducing properties. Anodic polarization revealed oxidation of the evaluated electrolytes at potentials below +600 mV SCE. It was observed that the UFRJ and USP-RP solutions presented more intense oxidation and reduction processes as compared to the Mondelli and SAGF solutions.

  20. Preservation of urine free catecholamines and their free O-methylated metabolites with citric acid as an alternative to hydrochloric acid for LC-MS/MS-based analyses.

    PubMed

    Peitzsch, Mirko; Pelzel, Daniela; Lattke, Peter; Siegert, Gabriele; Eisenhofer, Graeme

    2016-01-01

    Measurements of urinary fractionated metadrenalines provide a useful screening test to diagnose phaeochromocytoma. Stability of these compounds and their parent catecholamines during and after urine collection is crucial to ensure accuracy of the measurements. Stabilisation with hydrochloric acid (HCl) can promote deconjugation of sulphate-conjugated metadrenalines, indicating a need for alternative preservatives. Urine samples with an intrinsically acidic or alkaline pH (5.5-6.9 or 7.1-8.7, respectively) were used to assess stability of free catecholamines and their free O-methylated metabolites over 7 days of room temperature storage. Stabilisation with HCl was compared with ethylenediaminetetraacetic acid/metabisulphite and monobasic citric acid. Catecholamines and metabolites were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Free catecholamines and their O-methylated metabolites were stable in acidic urine samples over 7 days of room temperature storage, independent of the presence or absence of any stabilisation method. In contrast, free catecholamines, but not the free O-methylated metabolites, showed rapid degradation within 24 h and continuing degradation over 7 days in urine samples with an alkaline pH. Adjustment of alkaline urine samples to a pH of 3-5 with HCl or 4.8-5.4 with citric acid completely blocked degradation of catecholamines. Ethylenediaminetetraacetic acid/metabisulphite, although reducing the extent of degradation of catecholamines in alkaline urine, was largely ineffectual as a stabiliser. Citric acid is equally effective as HCl for stabilisation of urinary free catecholamines and minimises hazards associated with use of strong inorganic acids while avoiding deconjugation of sulphate-conjugated metabolites during simultaneous LC-MS/MS measurements of free catecholamines and their free O-methylated metabolites.

  1. A new LC-MS/MS bioanalytical method for atenolol in human plasma and milk.

    PubMed

    Phyo Lwin, Ei Mon; Gerber, Cobus; Song, Yunmei; Leggett, Catherine; Ritchie, Usha; Turner, Sean; Garg, Sanjay

    2017-04-01

    A new sensitive LC-MS/MS method for the quantification of atenolol in human plasma and milk has been developed for clinical lactation studies. Atenolol and the internal standard, phenazone, were extracted from biological matrices by protein precipitation. A Phenomenex ® C-18 column and gradient chromatographic conditions were used for separation of the analyte, followed by detection with MS. Stability of samples was confirmed for atenolol in human plasma and milk for up to 3 months. Linearity range of 1-800 ng/ml (r 2 = 0.9995), the precision within 15% CV and the recovery of the analyte (80-100% range) were achieved. A new validated analytical method for atenolol in plasma and milk was developed.

  2. A liquid chromatography/tandem mass spectrometry assay for the analysis of atomoxetine in human plasma and in vitro cellular samples

    PubMed Central

    Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie

    2012-01-01

    A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222

  3. Spectroscopic characterization and quantitative determination of atorvastatin calcium impurities by novel HPLC method

    NASA Astrophysics Data System (ADS)

    Gupta, Lokesh Kumar

    2012-11-01

    Seven process related impurities were identified by LC-MS in the atorvastatin calcium drug substance. These impurities were identified by LC-MS. The structure of impurities was confirmed by modern spectroscopic techniques like 1H NMR and IR and physicochemical studies conducted by using synthesized authentic reference compounds. The synthesized reference samples of the impurity compounds were used for the quantitative HPLC determination. These impurities were detected by newly developed gradient, reverse phase high performance liquid chromatographic (HPLC) method. The system suitability of HPLC analysis established the validity of the separation. The analytical method was validated according to International Conference of Harmonization (ICH) with respect to specificity, precision, accuracy, linearity, robustness and stability of analytical solutions to demonstrate the power of newly developed HPLC method.

  4. Critical Nucleation Length for Accelerating Frictional Slip

    NASA Astrophysics Data System (ADS)

    Aldam, Michael; Weikamp, Marc; Spatschek, Robert; Brener, Efim A.; Bouchbinder, Eran

    2017-11-01

    The spontaneous nucleation of accelerating slip along slowly driven frictional interfaces is central to a broad range of geophysical, physical, and engineering systems, with particularly far-reaching implications for earthquake physics. A common approach to this problem associates nucleation with an instability of an expanding creep patch upon surpassing a critical length Lc. The critical nucleation length Lc is conventionally obtained from a spring-block linear stability analysis extended to interfaces separating elastically deformable bodies using model-dependent fracture mechanics estimates. We propose an alternative approach in which the critical nucleation length is obtained from a related linear stability analysis of homogeneous sliding along interfaces separating elastically deformable bodies. For elastically identical half-spaces and rate-and-state friction, the two approaches are shown to yield Lc that features the same scaling structure, but with substantially different numerical prefactors, resulting in a significantly larger Lc in our approach. The proposed approach is also shown to be naturally applicable to finite-size systems and bimaterial interfaces, for which various analytic results are derived. To quantitatively test the proposed approach, we performed inertial Finite-Element-Method calculations for a finite-size two-dimensional elastically deformable body in rate-and-state frictional contact with a rigid body under sideway loading. We show that the theoretically predicted Lc and its finite-size dependence are in reasonably good quantitative agreement with the full numerical solutions, lending support to the proposed approach. These results offer a theoretical framework for predicting rapid slip nucleation along frictional interfaces.

  5. Crystal structure of cGMP-dependent protein kinase Iβ cyclic nucleotide-binding-B domain : Rp-cGMPS complex reveals an apo-like, inactive conformation

    DOE PAGES

    Campbell, James C.; VanSchouwen, Bryan; Lorenz, Robin; ...

    2016-12-23

    The R-diastereomer of phosphorothioate analogs of cGMP, Rp-cGMPS, is one of few known inhibitors of cGMP-dependent protein kinase I (PKG I); however, its mechanism of inhibition is currently not fully understood. We determined the crystal structure of the PKG Iβ cyclic nucleotide-binding domain (PKG Iβ CNB-B), considered a ‘gatekeeper’ for cGMP activation, bound to Rp-cGMPS at 1.3 Å. Our structural and NMR data show that PKG Iβ CNB-B bound to Rp-cGMPS displays an apo-like structure with its helical domain in an open conformation. Comparison with the cAMP-dependent protein kinase regulatory subunit (PKA RIα) showed that this conformation resembles the catalyticmore » subunit-bound inhibited state of PKA RIα more closely than the apo or Rp-cAMPS-bound conformations. Our results suggest that Rp-cGMPS inhibits PKG I by stabilizing the inactive conformation of CNB-B.« less

  6. Soil organic matter composition from correlated thermal analysis and nuclear magnetic resonance data in Australian national inventory of agricultural soils

    NASA Astrophysics Data System (ADS)

    Moore, T. S.; Sanderman, J.; Baldock, J.; Plante, A. F.

    2016-12-01

    National-scale inventories typically include soil organic carbon (SOC) content, but not chemical composition or biogeochemical stability. Australia's Soil Carbon Research Programme (SCaRP) represents a national inventory of SOC content and composition in agricultural systems. The program used physical fractionation followed by 13C nuclear magnetic resonance (NMR) spectroscopy. While these techniques are highly effective, they are typically too expensive and time consuming for use in large-scale SOC monitoring. We seek to understand if analytical thermal analysis is a viable alternative. Coupled differential scanning calorimetry (DSC) and evolved gas analysis (CO2- and H2O-EGA) yields valuable data on SOC composition and stability via ramped combustion. The technique requires little training to use, and does not require fractionation or other sample pre-treatment. We analyzed 300 agricultural samples collected by SCaRP, divided into four fractions: whole soil, coarse particulates (POM), untreated mineral associated (HUM), and hydrofluoric acid (HF)-treated HUM. All samples were analyzed by DSC-EGA, but only the POM and HF-HUM fractions were analyzed by NMR. Multivariate statistical analyses were used to explore natural clustering in SOC composition and stability based on DSC-EGA data. A partial least-squares regression (PLSR) model was used to explore correlations among the NMR and DSC-EGA data. Correlations demonstrated regions of combustion attributable to specific functional groups, which may relate to SOC stability. We are increasingly challenged with developing an efficient technique to assess SOC composition and stability at large spatial and temporal scales. Correlations between NMR and DSC-EGA may demonstrate the viability of using thermal analysis in lieu of more demanding methods in future large-scale surveys, and may provide data that goes beyond chemical composition to better approach quantification of biogeochemical stability.

  7. Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation.

    PubMed

    van Heugten, A J P; de Boer, W; de Vries, W S; Markesteijn, C M A; Vromans, H

    2018-02-05

    A stability indicating high performance liquid chromatography method has been developed for the determination of triamcinolone acetonide (TCA) and its main degradation products in ointment formulations. The method, based on extensive stress testing using metal salts, azobisisobutyronitrile, acid, base and peroxide, showed that TCA undergoes oxidative degradation. All degradation products were identified using HPLC mass spectrometry. Separation and quantification was achieved using an Altima C18 RP18 HP column (250×4.6mm 2 , with 5μm particles) using a mobile phase consisting of acetonitrile and water buffered at pH 7 using 10mM phosphate buffer. A gradient mode was operated at a flow rate of 1.5ml/min and detection was at 241nm. The method showed linearity for TCA and Impurity C in 0.02-125% of the workload, both square roots of the correlation coefficients were larger than 0.9999. Repeatability and intermediate precision were performed by six consecutive injections of both 1.25% and 125% of the work load for both TCA and Impurity C divided equally over two days. RSD were 0.6% and 0.7% for TCA and 0.5% and 0.1% for Impurity C respectively. Accuracy was determined as well, the average recoveries were 99.5% (±0.1%, n=3) for TCA and 96.9% (±1.3%, n=3) for impurity C respectively from spiked ointment samples. The robustness was also evaluated by variations of column (old vs new), mobile phase pH and filter retention. The applicability of the method was evaluated by analysis of a commercial ointment formulation. Interestingly, the extensive stress tests were able to predict all degradation products of TCA in a long term stability ointment sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Does Surgical Stabilization of Lateral Compression-type Pelvic Ring Fractures Decrease Patients' Pain, Reduce Narcotic Use, and Improve Mobilization?

    PubMed

    Hagen, Jennifer; Castillo, Renan; Dubina, Andrew; Gaski, Greg; Manson, Theodore T; O'Toole, Robert V

    2016-06-01

    Debate remains over the role of surgical treatment in minimally displaced lateral compression (Young-Burgess, LC, OTA 61-B1/B2) pelvic ring injuries. Lateral compression type 1 (LC1) injuries are defined by an impaction fracture at the sacrum; type 2 (LC2) are defined by a fracture that extends through the posterior iliac wing at the level of the sacroiliac joint. Some believe that operative stabilization of these fractures limits pain and eases mobilization, but to our knowledge there are few controlled studies on the topic. (1) Does operative stabilization of LC1 and LC2 pelvic fractures decrease patients' narcotic use and lower their visual analog scale pain scores? (2) Does stabilization allow patients to mobilize earlier with physical therapy? This retrospective study of LC1 and LC2 fractures evaluated patients treated definitively at one institution from 2007 to 2013. All patients treated surgically, all nonoperative LC2, and all nonoperative LC1 fractures with complete sacral injury were included. In general, LC1 or LC2 fractures with greater than 10 mm of displacement and/or sagittal/axial plane deformity on static radiographs were treated surgically. One hundred fifty-eight patients in the LC1 group (107 [of 697 screened] nonoperative, 51 surgical) and 123 patients in the LC2 group (78 nonoperative, 45 surgical) met inclusion criteria. The surgical and nonoperative groups were matched for fracture type. To account for differences between patients treated surgically and nonoperatively, we used propensity modeling techniques incorporating treatment predictors. Propensity scores demonstrated good overlap and were used as part of multiple variable regression models to account for selection bias between the surgically treated and nonoperative groups. Patient-reported pain scores and narcotic administration were tallied in 24-hour increments during the first 24 hours of hospitalization, at 48 hours after intervention, and in the 24 hours before discharge. Time from intervention to mobilization out of bed was recorded; intervention was defined as the date of definitive surgical intervention or the day the surgeon determined the patient would be treated without surgery. There was no difference in the narcotics distributed to any of the groups with the exception that the patients with surgically treated LC2 fractures used, on average (mean [95% confidence interval]) 40.2 (-72.9 to -7.6) mg morphine less at the 48-hour mark (p = 0.016). In general, there were no differences between the groups' pain scores. The surgically treated patients with LC1 fractures mobilized 1.7 (-3.3 to -0.01) days earlier (p = 0.034) than their nonoperative counterparts. There was no difference in the LC2 cohort in terms of time to mobilization between those treated with and without surgery. There were few differences in pain scores and morphine use between the surgical and nonoperative groups, and the differences observed likely were not clinically important. We found no evidence that surgical stabilization of certain LC1 and LC2 pelvic fractures improves patients' pain, decreases their narcotic use, and improves time to mobilization. A randomized trial of patients with similar fractures and similar degrees initial displacement would help remove some of the confounders present in this study. Level III, therapeutic study.

  9. Isolation of a small molecule with anti-MRSA activity from a mangrove symbiont Streptomyces sp. PVRK-1 and its biomedical studies in Zebrafish embryos

    PubMed Central

    Kannan, Rajaretinam Rajesh; Iniyan, Appadurai Muthamil; Prakash, Vincent Samuel Gnana

    2011-01-01

    Objective The aim of the present study was to isolate the anti-MRSA (Methicillin Resistant Staphylococcus aureus) molecule from the Mangrove symbiont Streptomyces and its biomedical studies in Zebrafish embryos. Methods MRSA was isolated from the pus samples of Colachal hospitals and confirmed by amplification of mecA gene. Anti-MRSA molecule producing strain was identified by 16s rRNA gene sequencing. Anti-MRSA compound production was optimized by Solid State Fermentation (SSF) and the purification of the active molecule was carried out by TLC and RP-HPLC. The inhibitory concentration and LC50 were calculated using Statistical software SPSS. The Biomedical studies including the cardiac assay and organ toxicity assessment were carried out in Zebrafish. Results The bioactive anti-MRSA small molecule A2 was purified by TLC with Rf value of 0.37 with 1.389 retention time at RP-HPLC. The Inhibitory Concentration of the purified molecule A2 was 30 µg/mL but, the inhibitory concentration of the MRSA in the infected embryo was 32-34 µg/mL for TLC purified molecule A2 with LC50 mean value was 61.504 µg/mL. Zebrafish toxicity was assessed in 48-60 µg/mL by observing the physiological deformities and the heart beat rates (HBR) of embryos for anti MRSA molecule showed the mean of 41.33-41.67 HBR/15 seconds for 40 µg/mL and control was 42.33-42.67 for 15 seconds which significantly showed that the anti-MRSA molecule A2 did not affected the HBR. Conclusions Anti-MRSA molecule from Streptomyces sp PVRK-1 was isolated and biomedical studies in Zebrafish model assessed that the molecule was non toxic at the minimal inhibitory concentration of MRSA. PMID:23569790

  10. Methods for the analysis of organophosphorus flame retardants-Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS.

    PubMed

    Tokumura, Masahiro; Miyake, Yuichi; Wang, Qi; Nakayama, Hayato; Amagai, Takashi; Ogo, Sayaka; Kume, Kazunari; Kobayashi, Takeshi; Takasu, Shinji; Ogawa, Kumiko

    2018-04-16

    Organophosphorus flame retardants (PFRs) are extensively used as alternatives to banned polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). In this study, we analyzed 14 PFRs by means of four mass-spectrometry-based methods: gas chromatography combined with electron-impact mass spectrometry (GC-EI-MS) or negative-chemical-ionization mass spectrometry (GC-NCI-MS) and liquid chromatography combined with tandem mass spectrometry using electrospray ionization (LC-ESI-MS/MS) or atmospheric pressure chemical ionization (LC-APCI-MS/MS). The limits of quantification (LOQs) for LC-ESI-MS/MS and LC-APCI-MS/MS (0.81-970 pg) were 1-2 orders of magnitude lower than the LOQs for GC-EI-MS and GC-NCI-MS (2.3-3900 pg). LC-APCI-MS/MS showed the lowest LOQs (mean = 41 pg; median = 3.4 pg) for all but two of the PFRs targeted in this study. For LC-APCI-MS/MS, the lowest LOQ was observed for tributyl phosphate (TBP) (0.81 pg), and the highest was observed for tris(butoxyethyl) phosphate (TBOEP) (36 pg). The results of this study indicate that LC-APCI-MS/MS is the optimum analytical method for the target PFRs, at least in terms of LOQ.

  11. Selection and Validation of Reference Genes for qRT-PCR Expression Analysis of Candidate Genes Involved in Olfactory Communication in the Butterfly Bicyclus anynana

    PubMed Central

    Arun, Alok; Baumlé, Véronique; Amelot, Gaël; Nieberding, Caroline M.

    2015-01-01

    Real-time quantitative reverse transcription PCR (qRT-PCR) is a technique widely used to quantify the transcriptional expression level of candidate genes. qRT-PCR requires the selection of one or several suitable reference genes, whose expression profiles remain stable across conditions, to normalize the qRT-PCR expression profiles of candidate genes. Although several butterfly species (Lepidoptera) have become important models in molecular evolutionary ecology, so far no study aimed at identifying reference genes for accurate data normalization for any butterfly is available. The African bush brown butterfly Bicyclus anynana has drawn considerable attention owing to its suitability as a model for evolutionary ecology, and we here provide a maiden extensive study to identify suitable reference gene in this species. We monitored the expression profile of twelve reference genes: eEF-1α, FK506, UBQL40, RpS8, RpS18, HSP, GAPDH, VATPase, ACT3, TBP, eIF2 and G6PD. We tested the stability of their expression profiles in three different tissues (wings, brains, antennae), two developmental stages (pupal and adult) and two sexes (male and female), all of which were subjected to two food treatments (food stress and control feeding ad libitum). The expression stability and ranking of twelve reference genes was assessed using two algorithm-based methods, NormFinder and geNorm. Both methods identified RpS8 as the best suitable reference gene for expression data normalization. We also showed that the use of two reference genes is sufficient to effectively normalize the qRT-PCR data under varying tissues and experimental conditions that we used in B. anynana. Finally, we tested the effect of choosing reference genes with different stability on the normalization of the transcript abundance of a candidate gene involved in olfactory communication in B. anynana, the Fatty Acyl Reductase 2, and we confirmed that using an unstable reference gene can drastically alter the expression profile of the target candidate genes. PMID:25793735

  12. Selection and validation of reference genes for qRT-PCR expression analysis of candidate genes involved in olfactory communication in the butterfly Bicyclus anynana.

    PubMed

    Arun, Alok; Baumlé, Véronique; Amelot, Gaël; Nieberding, Caroline M

    2015-01-01

    Real-time quantitative reverse transcription PCR (qRT-PCR) is a technique widely used to quantify the transcriptional expression level of candidate genes. qRT-PCR requires the selection of one or several suitable reference genes, whose expression profiles remain stable across conditions, to normalize the qRT-PCR expression profiles of candidate genes. Although several butterfly species (Lepidoptera) have become important models in molecular evolutionary ecology, so far no study aimed at identifying reference genes for accurate data normalization for any butterfly is available. The African bush brown butterfly Bicyclus anynana has drawn considerable attention owing to its suitability as a model for evolutionary ecology, and we here provide a maiden extensive study to identify suitable reference gene in this species. We monitored the expression profile of twelve reference genes: eEF-1α, FK506, UBQL40, RpS8, RpS18, HSP, GAPDH, VATPase, ACT3, TBP, eIF2 and G6PD. We tested the stability of their expression profiles in three different tissues (wings, brains, antennae), two developmental stages (pupal and adult) and two sexes (male and female), all of which were subjected to two food treatments (food stress and control feeding ad libitum). The expression stability and ranking of twelve reference genes was assessed using two algorithm-based methods, NormFinder and geNorm. Both methods identified RpS8 as the best suitable reference gene for expression data normalization. We also showed that the use of two reference genes is sufficient to effectively normalize the qRT-PCR data under varying tissues and experimental conditions that we used in B. anynana. Finally, we tested the effect of choosing reference genes with different stability on the normalization of the transcript abundance of a candidate gene involved in olfactory communication in B. anynana, the Fatty Acyl Reductase 2, and we confirmed that using an unstable reference gene can drastically alter the expression profile of the target candidate genes.

  13. Recent advances in numerical PDEs

    NASA Astrophysics Data System (ADS)

    Zuev, Julia Michelle

    In this thesis, we investigate four neighboring topics, all in the general area of numerical methods for solving Partial Differential Equations (PDEs). Topic 1. Radial Basis Functions (RBF) are widely used for multi-dimensional interpolation of scattered data. This methodology offers smooth and accurate interpolants, which can be further refined, if necessary, by clustering nodes in select areas. We show, however, that local refinements with RBF (in a constant shape parameter [varepsilon] regime) may lead to the oscillatory errors associated with the Runge phenomenon (RP). RP is best known in the case of high-order polynomial interpolation, where its effects can be accurately predicted via Lebesgue constant L (which is based solely on the node distribution). We study the RP and the applicability of Lebesgue constant (as well as other error measures) in RBF interpolation. Mainly, we allow for a spatially variable shape parameter, and demonstrate how it can be used to suppress RP-like edge effects and to improve the overall stability and accuracy. Topic 2. Although not as versatile as RBFs, cubic splines are useful for interpolating grid-based data. In 2-D, we consider a patch representation via Hermite basis functions s i,j ( u, v ) = [Special characters omitted.] h mn H m ( u ) H n ( v ), as opposed to the standard bicubic representation. Stitching requirements for the rectangular non-equispaced grid yield a 2-D tridiagonal linear system AX = B, where X represents the unknown first derivatives. We discover that the standard methods for solving this NxM system do not take advantage of the spline-specific format of the matrix B. We develop an alternative approach using this specialization of the RHS, which allows us to pre-compute coefficients only once, instead of N times. MATLAB implementation of our fast 2-D cubic spline algorithm is provided. We confirm analytically and numerically that for large N ( N > 200), our method is at least 3 times faster than the standard algorithm and is just as accurate. Topic 3. The well-known ADI-FDTD method for solving Maxwell's curl equations is second-order accurate in space/time, unconditionally stable, and computationally efficient. We research Richardson extrapolation -based techniques to improve time discretization accuracy for spatially oversampled ADI-FDTD. A careful analysis of temporal accuracy, computational efficiency, and the algorithm's overall stability is presented. Given the context of wave- type PDEs, we find that only a limited number of extrapolations to the ADI-FDTD method are beneficial, if its unconditional stability is to be preserved. We propose a practical approach for choosing the size of a time step that can be used to improve the efficiency of the ADI-FDTD algorithm, while maintaining its accuracy and stability. Topic 4. Shock waves and their energy dissipation properties are critical to understanding the dynamics controlling the MHD turbulence. Numerical advection algorithms used in MHD solvers (e.g. the ZEUS package) introduce undesirable numerical viscosity. To counteract its effects and to resolve shocks numerically, Richtmyer and von Neumann's artificial viscosity is commonly added to the model. We study shock power by analyzing the influence of both artificial and numerical viscosity on energy decay rates. Also, we analytically characterize the numerical diffusivity of various advection algorithms by quantifying their diffusion coefficients e.

  14. A quantitative LC-MS/MS method for simultaneous determination of cocaine and its metabolites in whole blood

    PubMed Central

    Chen, Xiabin; Zheng, Xirong; Ding, Kai; Zhou, Ziyuan; Zhan, Chang-Guo; Zheng, Fang

    2016-01-01

    As new metabolic pathways of cocaine were recently identified, a high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed to simultaneously determine cocaine and nine cocaine-related metabolites in whole blood samples. One-step solid phase extraction was used to extract all of the ten compounds and corresponding internal standards from blood samples. All compounds and internal standards extracted were separated on an Atlantis T3 (100Å, 3 µm, 2.1 mm × 150 mm I.D) column and detected in positive ion and high sensitivity mode with multiple reaction monitoring. This method was validated for its sensitivity, linearity, specificity, accuracy, precision, recovery, and stability. All of the ten compounds were quantifiable ranging from the lower limit of quantification (LLOQs) of ~10 nM (1.9–3.2 ng/ml) to ~1000 nM (190–320 ng/ml) without any interfering substance. Accuracy and precision were determined, and both of them were within the acceptance criteria of the United States (US) Food and Drug Administration (FDA) and European Medicines Agency (EMA) guidelines. The recovery was above 66.7% for all compounds. Stability tests demonstrated the stability of compounds under different storage conditions in whole blood samples. The method was successfully applied to a pharmacokinetic study with co-administration of cocaine and alcohol in rats. PMID:27923200

  15. Leachable diphenylguanidine from rubber closures used in pre-filled syringes: A case study to understand solid and solution interactions with oxytocin.

    PubMed

    Zidan, Ahmed S; Aqueel, Sabir M; Alayoubi, Alaadin; Mohammad, Adil; Zhang, Jinhui; Rahman, Ziyaur; Faustino, Patrick; Lostritto, Richard T; Ashraf, Muhammad

    2017-10-30

    Leachables derived from multi-component drug-device syringe systems can result in changes to the quality of drug products. Diphenylguanidine (DPG), a leachable released from styrene butadiene rubber syringe plungers, interacts with Oxytocin to form protein-adducts. This study investigated the mechanism and kinetics of this interaction in both solid and solution states through in-vitro tests and spectroscopic methods For solid state interaction, the protein-adducts with DPG were characterized using SEM, XRD, DSC, FTIR, 13 C ss NMR, and dissolution analysis. For solution state interaction, LC-HRMS was used to assess stability of Oxytocin solutions in presence of various concentrations of DPG at 25°C and 40°C for 4 weeks. Moreover, molecular docking analysis was used to identify possible molecular configurations of the interaction.Results were consistent with the formation of a new solid state with distorted surface morphology for oxytocin-DPG adducts, in which the oxytocin carbonyl group(s) and the secondary amine groups of DPG interact. This interaction was also confirmed by molecular docking analysis through hydrogen bonding (2.31Å) and Van der Waal attraction (3.14Å). Moreover, LC-HRMS analysis revealed an increase in Oxytocin stability and suppression of Oxytocin dimerization by DPG. A potential reduction in the rate of Oxytocin dissolution from the formed adducts was indicative of its strong association with DPG. Hence, the leaching potential of DPG from rubber closures and plungers should be monitored and controlled to maintain the quality and stability of the pharmaceutical product. Published by Elsevier B.V.

  16. Development of Impurity Profiling Methods Using Modern Analytical Techniques.

    PubMed

    Ramachandra, Bondigalla

    2017-01-02

    This review gives a brief introduction about the process- and product-related impurities and emphasizes on the development of novel analytical methods for their determination. It describes the application of modern analytical techniques, particularly the ultra-performance liquid chromatography (UPLC), liquid chromatography-mass spectrometry (LC-MS), high-resolution mass spectrometry (HRMS), gas chromatography-mass spectrometry (GC-MS) and high-performance thin layer chromatography (HPTLC). In addition to that, the application of nuclear magnetic resonance (NMR) spectroscopy was also discussed for the characterization of impurities and degradation products. The significance of the quality, efficacy and safety of drug substances/products, including the source of impurities, kinds of impurities, adverse effects by the presence of impurities, quality control of impurities, necessity for the development of impurity profiling methods, identification of impurities and regulatory aspects has been discussed. Other important aspects that have been discussed are forced degradation studies and the development of stability indicating assay methods.

  17. Mutation analysis of pre-mRNA splicing genes in Chinese families with retinitis pigmentosa

    PubMed Central

    Pan, Xinyuan; Chen, Xue; Liu, Xiaoxing; Gao, Xiang; Kang, Xiaoli; Xu, Qihua; Chen, Xuejuan; Zhao, Kanxing; Zhang, Xiumei; Chu, Qiaomei; Wang, Xiuying

    2014-01-01

    Purpose Seven genes involved in precursor mRNA (pre-mRNA) splicing have been implicated in autosomal dominant retinitis pigmentosa (adRP). We sought to detect mutations in all seven genes in Chinese families with RP, to characterize the relevant phenotypes, and to evaluate the prevalence of mutations in splicing genes in patients with adRP. Methods Six unrelated families from our adRP cohort (42 families) and two additional families with RP with uncertain inheritance mode were clinically characterized in the present study. Targeted sequence capture with next-generation massively parallel sequencing (NGS) was performed to screen mutations in 189 genes including all seven pre-mRNA splicing genes associated with adRP. Variants detected with NGS were filtered with bioinformatics analyses, validated with Sanger sequencing, and prioritized with pathogenicity analysis. Results Mutations in pre-mRNA splicing genes were identified in three individual families including one novel frameshift mutation in PRPF31 (p.Leu366fs*1) and two known mutations in SNRNP200 (p.Arg681His and p.Ser1087Leu). The patients carrying SNRNP200 p.R681H showed rapid disease progression, and the family carrying p.S1087L presented earlier onset ages and more severe phenotypes compared to another previously reported family with p.S1087L. In five other families, we identified mutations in other RP-related genes, including RP1 p. Ser781* (novel), RP2 p.Gln65* (novel) and p.Ile137del (novel), IMPDH1 p.Asp311Asn (recurrent), and RHO p.Pro347Leu (recurrent). Conclusions Mutations in splicing genes identified in the present and our previous study account for 9.5% in our adRP cohort, indicating the important role of pre-mRNA splicing deficiency in the etiology of adRP. Mutations in the same splicing gene, or even the same mutation, could correlate with different phenotypic severities, complicating the genotype–phenotype correlation and clinical prognosis. PMID:24940031

  18. Stability-Indicating Reversed-Phase UHPLC Method Development and Characterization of Degradation Products of Almotriptan Maleate by LC-QTOF-MS/MS.

    PubMed

    Saibaba, B; Vishnuvardhan, Ch; Johnsi Rani, P; Satheesh Kumar, N

    2018-01-01

    Almotriptan maleate (ALMT), a highly selective 5-hydroxy tryptamine 1B/1D (5-HT1B/1D) receptor agonist used in the treatment of migraine headache was subjected to various ICH (Q1A (R2)) specified guidelines. The drug underwent significant degradation under hydrolytic (acid, base and neutral), oxidative and photolytic stress conditions, while it was stable under thermal stress condition. A total of seven significant degradation products (DPs) were obtained. A simple, selective and reliable UPLC method has been developed for the separation of ALMT and its DPs using Acquity UPLC HSS Cyano (100 × 2.1 mm, 1.8 μm) column with mobile phase consisting of ammonium acetate (10 mM, pH 4.4) buffer and acetonitrile in gradient elution mode. Chromatographic analysis was performed at a flow rate of 0.3 mL/min using a PDA detector at a wavelength of 230 nm. All the DPs (DP-1 to DP-7) were characterized using UHPLC-ESI-QTOF based on mass fragmentation pattern and accurate m/z values. The developed UPLC method was validated in terms of specificity, linearity, precision and accuracy. The developed stability-indicating method helps in quantification of drug in the presence of DPs. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Human methyl purine DNA glycosylase and DNA polymerase ß expression collectively predict sensitivity to temozolomide

    PubMed Central

    Trivedi, Ram N.; Wang, Xiao-hong; Jelezcova, Elena; Goellner, Eva M.; Tang, Jiangbo; Sobol, Robert W.

    2014-01-01

    Over-expression of N-methylpurine DNA glycosylase (MPG) has been suggested as a possible gene therapy approach to sensitize tumor cells to the cell killing effects of temozolomide, an imidazotetrazine-class chemotherapeutic alkylating agent. In the present study, we show that both elevated MPG expression and shRNA-mediated loss of Pol ß expression in human breast cancer cells increases cellular sensitivity to temozolomide. Resistance to temozolomide is restored by complementation of either wild-type human Pol ß or human Pol ß with an inactivating mutation specific to the polymerase active site yet functional for 5′dRP lyase activity. These genetic and cellular studies uniquely demonstrate that over-expression of MPG causes an imbalance in BER leading to an accumulation of cytotoxic 5′dRP lesions and that the 5′dRP lyase activity of Pol ß is required to restore resistance to temozolomide. These results imply that Pol ß dependent 5′dRP lyase activity is the rate-limiting step in BER in these cells and suggests that BER is a tightly balanced pathway for the repair of alkylated bases such as N7-MeG and N3-MeA. Further, we find that 5′dRP-mediated cell death is independent of caspase-3 activation and does not induce the formation of autophagosomes, as measured by GFP-LC3 localization. The experiments presented herein suggest that it will be important to investigate whether an active BER pathway could be partially responsible for the temozolomide-mediated resistance seen in some tumors and that balanced BER protein expression and overall BER capacity may help predict sensitivity to temozolomide. PMID:18477668

  20. Interpenetrating polymer network approach to tougher and more microcracking resistant high temperature polymers. I - LaRC-RP40

    NASA Technical Reports Server (NTRS)

    Pater, Ruth H.; Morgan, Cassandra D.

    1988-01-01

    Interpenetrating polymer networks in the form of the LaRC-RP40 resin, prepared by the in situ polymerization of a thermosetting imide prepolymer and thermoplastic monomer reactants, are presently used to obtain toughness and microcracking resistance in a high-temperature polymer. Attention is presently given to the processing, physical, and mechanical properties, as well as the thermooxidative stability, of both the neat resin and the resin as a graphite fiber-reinforced matrix. Microcracking after thermal cycling was also tested. LaRC-RP40 exhibits significant resin fracture toughness improvements over the PMR-15 high-temperature matrix resin.

  1. Interpenetrating polymer network approach to tougher and more microcracking resistant high temperature polymers. I. LaRC-RP40

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pater, R.H.; Morgan, C.D.

    1988-10-01

    Interpenetrating polymer networks in the form of the LaRC-RP40 resin, prepared by the in situ polymerization of a thermosetting imide prepolymer and thermoplastic monomer reactants, are presently used to obtain toughness and microcracking resistance in a high-temperature polymer. Attention is presently given to the processing, physical, and mechanical properties, as well as the thermooxidative stability, of both the neat resin and the resin as a graphite fiber-reinforced matrix. Microcracking after thermal cycling was also tested. LaRC-RP40 exhibits significant resin fracture toughness improvements over the PMR-15 high-temperature matrix resin. 16 references.

  2. Comparison of originator and biosimilar therapeutic monoclonal antibodies using comprehensive two-dimensional liquid chromatography coupled with time-of-flight mass spectrometry.

    PubMed

    Sorensen, Matthew; Harmes, David C; Stoll, Dwight R; Staples, Gregory O; Fekete, Szabolcs; Guillarme, Davy; Beck, Alain

    2016-10-01

    As research, development, and manufacturing of biosimilar protein therapeutics proliferates, there is great interest in the continued development of a portfolio of complementary analytical methods that can be used to efficiently and effectively characterize biosimilar candidate materials relative to the respective reference (i.e., originator) molecule. Liquid phase separation techniques such as liquid chromatography and capillary electrophoresis are powerful tools that can provide both qualitative and quantitative information about similarities and differences between reference and biosimilar materials, especially when coupled with mass spectrometry. However, the inherent complexity of these protein materials challenges even the most modern one-dimensional (1D) separation methods. Two-dimensional (2D) separations present a number of potential advantages over 1D methods, including increased peak capacity, 2D peak patterns that can facilitate unknown identification, and improvement in the compatibility of some separation methods with mass spectrometry. In this study, we demonstrate the use of comprehensive 2D-LC separations involving cation-exchange (CEX) and reversed-phase (RP) separations in the first and second dimensions to compare 3 reference/biosimilar pairs of monoclonal antibodies (cetuximab, trastuzumab and infliximab) that cover a range of similarity/disimilarity in a middle-up approach. The second dimension RP separations are coupled to time-of-flight mass spectrometry, which enables direct identification of features in the chromatograms obtained from mAbs digested with the IdeS enzyme, or digestion with IdeS followed by reduction with dithiothreitol. As many as 23 chemically unique mAb fragments were detected in a single sample. Our results demonstrate that these rich datasets enable facile assesment of the degree of similarity between reference and biosimilar materials.

  3. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    PubMed

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Analysis of nifedipine in human plasma and amniotic fluid by liquid chromatography-tandem mass spectrometry and its application to clinical pharmacokinetics in hypertensive pregnant women.

    PubMed

    Filgueira, Gabriela Campos de Oliveira; Filgueira, Osmany Alberto Silva; Carvalho, Daniela Miarelli; Marques, Maria Paula; Moisés, Elaine Christine Dantas; Duarte, Geraldo; Lanchote, Vera Lucia; Cavalli, Ricardo Carvalho

    2015-07-01

    Nifedipine is a dihydropyridine calcium channel blocker used for the treatment of hypertension in pregnant women. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for analysis of nifedipine in human plasma and amniotic fluid. Separation of nifedipine and nitrendipine (IS) was performed using a LiChroCART(®) RP-Select B column and a mixture of water:acetonitrile:glacial acetic acid (30:70:0.5 v/v) as the mobile phase. Aliquots of 500μL of biological samples were extracted at pH 13 using dichloromethane:n-pentane (3:7 v/v). The validated method was applied to a study of the pharmacokinetics of nifedipine in human plasma and amniotic fluid samples collected up to 12h after administration of the last slow-release nifedipine (20mg/12h) dose to 12 hypertensive pregnant women. The estimated pharmacokinetic parameters of nifedipine showed a mean AUC(0-12) of 250.2ngh/mL, ClT/F of 89.2L/h, Vd/F of 600.0L and t1/2 5.1h. The mean amniotic fluid/plasma concentration ratio was 0.05. The methods proved to be highly sensitive by showing a lower quantification limit of 0.1ng/mL for both matrices. And this study reports for the first time the complete development and validation of the method to quantify nifedipine in amniotic fluid using LC-MS-MS. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Determination of triapine, a ribonucleotide reductase inhibitor, in human plasma by liquid chromatography tandem mass spectrometry.

    PubMed

    Feng, Ye; Kunos, Charles A; Xu, Yan

    2015-09-01

    Triapine is an inhibitor of ribonucleotide reductase (RNR). Studies have shown that triapine significantly decreases the activity of RNR and enhanced the radiation-mediated cytotoxicity in cervical and colon cancer. In this work, we have developed and validated a selective and sensitive LC-MS/MS method for the determination of triapine in human plasma. In this method, 2-[(3-fluoro-2-pyridinyl)methylene] hydrazinecarbothioamide (NSC 266749) was used as the internal standard (IS); plasma samples were prepared by deproteinization with acetonitrile; tripaine and the IS were separated on a Waters Xbridge Shield RP18 column (3.5 µm; 2.1 × 50 mm) using a mobile phase containing 25.0% methanol and 75.0% ammonium bicarbonate buffer (10.0 mM, pH 8.50; v/v); column eluate was monitored by positive turbo-ionspray tandem mass spectrometry; and quantitation of triapine was carried out in multiple-reaction-monitoring mode. The method developed had a linear calibration range of 0.250-50.0 ng/mL with correlation coefficient of 0.999 for triapine in human plasma. The IS-normalized recovery and the IS-normalized matrix factor of triapine were 101-104% and 0.89-1.05, respectively. The accuracy expressed as percentage error and precision expressed as coefficient of variation were ≤±6 and ≤8%, respectively. The validated LC-MS/MS method was applied to the measurement of triapine in patient samples from a phase I clinical trial. Copyright © 2015 John Wiley & Sons, Ltd.

  6. Bifurcation analysis of a photoreceptor interaction model for Retinitis Pigmentosa

    NASA Astrophysics Data System (ADS)

    Camacho, Erika T.; Radulescu, Anca; Wirkus, Stephen

    2016-09-01

    Retinitis Pigmentosa (RP) is the term used to describe a diverse set of degenerative eye diseases affecting the photoreceptors (rods and cones) in the retina. This work builds on an existing mathematical model of RP that focused on the interaction of the rods and cones. We non-dimensionalize the model and examine the stability of the equilibria. We then numerically investigate other stable modes that are present in the system for various parameter values and relate these modes to the original problem. Our results show that stable modes exist for a wider range of parameter values than the stability of the equilibrium solutions alone, suggesting that additional approaches to preventing cone death may exist.

  7. The Relevance of AgRP Neuron-Derived GABA Inputs to POMC Neurons Differs for Spontaneous and Evoked Release

    PubMed Central

    2017-01-01

    Hypothalamic agouti-related peptide (AgRP) neurons potently stimulate food intake, whereas proopiomelanocortin (POMC) neurons inhibit feeding. Whether AgRP neurons exert their orexigenic actions, at least in part, by inhibiting anorexigenic POMC neurons remains unclear. Here, the connectivity between GABA-releasing AgRP neurons and POMC neurons was examined in brain slices from male and female mice. GABA-mediated spontaneous IPSCs (sIPSCs) in POMC neurons were unaffected by disturbing GABA release from AgRP neurons either by cell type-specific deletion of the vesicular GABA transporter or by expression of botulinum toxin in AgRP neurons to prevent vesicle-associated membrane protein 2-dependent vesicle fusion. Additionally, there was no difference in the ability of μ-opioid receptor (MOR) agonists to inhibit sIPSCs in POMC neurons when MORs were deleted from AgRP neurons, and activation of the inhibitory designer receptor hM4Di on AgRP neurons did not affect sIPSCs recorded from POMC neurons. These approaches collectively indicate that AgRP neurons do not significantly contribute to the strong spontaneous GABA input to POMC neurons. Despite these observations, optogenetic stimulation of AgRP neurons reliably produced evoked IPSCs in POMC neurons, leading to the inhibition of POMC neuron firing. Thus, AgRP neurons can potently affect POMC neuron function without contributing a significant source of spontaneous GABA input to POMC neurons. Together, these results indicate that the relevance of GABAergic inputs from AgRP to POMC neurons is state dependent and highlight the need to consider different types of transmitter release in circuit mapping and physiologic regulation. SIGNIFICANCE STATEMENT Agouti-related peptide (AgRP) neurons play an important role in driving food intake, while proopiomelanocortin (POMC) neurons inhibit feeding. Despite the importance of these two well characterized neuron types in maintaining metabolic homeostasis, communication between these cells remains poorly understood. To provide clarity to this circuit, we made electrophysiological recordings from mouse brain slices and found that AgRP neurons do not contribute spontaneously released GABA onto POMC neurons, although when activated with channelrhodopsin AgRP neurons inhibit POMC neurons through GABA-mediated transmission. These findings indicate that the relevance of AgRP to POMC neuron GABA connectivity depends on the state of AgRP neuron activity and suggest that different types of transmitter release should be considered when circuit mapping. PMID:28667175

  8. The Relevance of AgRP Neuron-Derived GABA Inputs to POMC Neurons Differs for Spontaneous and Evoked Release.

    PubMed

    Rau, Andrew R; Hentges, Shane T

    2017-08-02

    Hypothalamic agouti-related peptide (AgRP) neurons potently stimulate food intake, whereas proopiomelanocortin (POMC) neurons inhibit feeding. Whether AgRP neurons exert their orexigenic actions, at least in part, by inhibiting anorexigenic POMC neurons remains unclear. Here, the connectivity between GABA-releasing AgRP neurons and POMC neurons was examined in brain slices from male and female mice. GABA-mediated spontaneous IPSCs (sIPSCs) in POMC neurons were unaffected by disturbing GABA release from AgRP neurons either by cell type-specific deletion of the vesicular GABA transporter or by expression of botulinum toxin in AgRP neurons to prevent vesicle-associated membrane protein 2-dependent vesicle fusion. Additionally, there was no difference in the ability of μ-opioid receptor (MOR) agonists to inhibit sIPSCs in POMC neurons when MORs were deleted from AgRP neurons, and activation of the inhibitory designer receptor hM4Di on AgRP neurons did not affect sIPSCs recorded from POMC neurons. These approaches collectively indicate that AgRP neurons do not significantly contribute to the strong spontaneous GABA input to POMC neurons. Despite these observations, optogenetic stimulation of AgRP neurons reliably produced evoked IPSCs in POMC neurons, leading to the inhibition of POMC neuron firing. Thus, AgRP neurons can potently affect POMC neuron function without contributing a significant source of spontaneous GABA input to POMC neurons. Together, these results indicate that the relevance of GABAergic inputs from AgRP to POMC neurons is state dependent and highlight the need to consider different types of transmitter release in circuit mapping and physiologic regulation. SIGNIFICANCE STATEMENT Agouti-related peptide (AgRP) neurons play an important role in driving food intake, while proopiomelanocortin (POMC) neurons inhibit feeding. Despite the importance of these two well characterized neuron types in maintaining metabolic homeostasis, communication between these cells remains poorly understood. To provide clarity to this circuit, we made electrophysiological recordings from mouse brain slices and found that AgRP neurons do not contribute spontaneously released GABA onto POMC neurons, although when activated with channelrhodopsin AgRP neurons inhibit POMC neurons through GABA-mediated transmission. These findings indicate that the relevance of AgRP to POMC neuron GABA connectivity depends on the state of AgRP neuron activity and suggest that different types of transmitter release should be considered when circuit mapping. Copyright © 2017 the authors 0270-6474/17/377362-11$15.00/0.

  9. Selective separation of lambdacyhalothrin by porous/magnetic molecularly imprinted polymers prepared by Pickering emulsion polymerization.

    PubMed

    Hang, Hui; Li, Chunxiang; Pan, Jianming; Li, Linzi; Dai, Jiangdong; Dai, Xiaohui; Yu, Ping; Feng, Yonghai

    2013-10-01

    Porous/magnetic molecularly imprinted polymers (PM-MIPs) were prepared by Pickering emulsion polymerization. The reaction was carried out in an oil/water emulsion using magnetic halloysite nanotubes as the stabilizer instead of a toxic surfactant. In the oil phase, the imprinting process was conducted by radical polymerization of functional and cross-linked monomers, and porogen chloroform generated steam under the high reaction temperature, which resulted in some pores decorated with easily accessible molecular binding sites within the as-made PM-MIPs. The characterization demonstrated that the PM-MIPs were porous and magnetic inorganic-polymer composite microparticles with magnetic sensitivity (M(s) = 0.7448 emu/g), thermal stability (below 473 K) and magnetic stability (over the pH range of 2.0-8.0). The PM-MIPs were used as a sorbent for the selective binding of lambdacyhalothrin (LC) and rapidly separated under an external magnetic field. The Freundlich isotherm model gave a good fit to the experimental data. The adsorption kinetics of the PM-MIPs was well described by pseudo-second-order kinetics, indicating that the chemical process could be the rate-limiting step in the adsorption of LC. The selective recognition experiments exhibited the outstanding selective adsorption effect of the PM-MIPs for target LC. Moreover, the PM-MIPs regeneration without significant loss in adsorption capacity was demonstrated by at least four repeated cycles. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Performance Metrics for Liquid Chromatography-Tandem Mass Spectrometry Systems in Proteomics Analyses*

    PubMed Central

    Rudnick, Paul A.; Clauser, Karl R.; Kilpatrick, Lisa E.; Tchekhovskoi, Dmitrii V.; Neta, Pedatsur; Blonder, Nikša; Billheimer, Dean D.; Blackman, Ronald K.; Bunk, David M.; Cardasis, Helene L.; Ham, Amy-Joan L.; Jaffe, Jacob D.; Kinsinger, Christopher R.; Mesri, Mehdi; Neubert, Thomas A.; Schilling, Birgit; Tabb, David L.; Tegeler, Tony J.; Vega-Montoto, Lorenzo; Variyath, Asokan Mulayath; Wang, Mu; Wang, Pei; Whiteaker, Jeffrey R.; Zimmerman, Lisa J.; Carr, Steven A.; Fisher, Susan J.; Gibson, Bradford W.; Paulovich, Amanda G.; Regnier, Fred E.; Rodriguez, Henry; Spiegelman, Cliff; Tempst, Paul; Liebler, Daniel C.; Stein, Stephen E.

    2010-01-01

    A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications. PMID:19837981

  11. Rapid prototyping modelling in oral and maxillofacial surgery: A two year retrospective study.

    PubMed

    Suomalainen, Anni; Stoor, Patricia; Mesimäki, Karri; Kontio, Risto K

    2015-12-01

    The use of rapid prototyping (RP) models in medicine to construct bony models is increasing. The aim of the study was to evaluate retrospectively the indication for the use of RP models in oral and maxillofacial surgery at Helsinki University Central Hospital during 2009-2010. Also, the used computed tomography (CT) examination - multislice CT (MSCT) or cone beam CT (CBCT) - method was evaluated. In total 114 RP models were fabricated for 102 patients. The mean age of the patients at the time of the production of the model was 50.4 years. The indications for the modelling included malignant lesions (29%), secondary reconstruction (25%), prosthodontic treatment (22%), orthognathic surgery or asymmetry (13%), benign lesions (8%), and TMJ disorders (4%). MSCT examination was used in 92 and CBCT examination in 22 cases. Most of the models (75%) were conventional hard tissue models. Models with colored tumour or other structure(s) of interest were ordered in 24%. Two out of the 114 models were soft tissue models. The main benefit of the models was in treatment planning and in connection with the production of pre-bent plates or custom made implants. The RP models both facilitate and improve treatment planning and intraoperative efficiency. Rapid prototyping, radiology, computed tomography, cone beam computed tomography.

  12. [Development of a standardized evaluation system for cataracta complicata in retinitis pigmentosa].

    PubMed

    Auffarth, G U; Faller, U; Tetz, M R; Krastel, H; Völcker, H E

    1997-07-01

    Retinitis pigmentosa (RP) is associated with the formation of a posterior subcapsular cataract (PSC). As only a small part of the crystalline lens is usually affected, it is sometimes difficult to determine to what extent the visual loss is caused by the PSC alone. The methodology was developed in analogy to a scoring system for posterior capsule opacification by Tetz et al. Following dilation of the pupil, standardized photographs of the anterior segments were obtained utilizing a Zeiss photoslitlamp model 40 SL/P. The PSC was scored by evaluating retroillumination photographs. The individual PSC index was calculated by multiplying the density of the opacification (graded from 0 to 4) by the area involved in the central 4 mm zone of the pupil (calculated between 0 and 1). For testing the reliability of the evaluation system in part 1 of this study, 11 RP patients with different grades of PSC were examined by three independent observers. In part 2 of this study 37 eyes of 24 RP patients, aged 47.2 +/- 11.8 years, were evaluated and the PSC index was correlated with different parameters (visual acuity, age, visual fields, eletroretinography). RESULTS PART 1: The cataract-density grades were between 1 and 4 in the 11 patients. In relation to the central 4-mm pupillary zone between 13 and 100% of the area were opacified. Cataract indices (density x area) were between 0.13 and 4.0 (Mean values: Examiner 1:1.41 +/- 1.49; Examiner 2:1.28 +/- 1.46; Examiner 3:1.22 +/- 1.44; differences not significant: P = 0.77). PART 2: After an average duration of RP of 23 years, the average cataract index of the 24 patients was 1.72 +/- 1.35. There was no correlation between cataract index and ERG or visual fields (r < 0.2; P > 0.4); however, there was a good correlation to visual acuity (r = -0.72; P = 0.0001). Patients with early onset of RP (before 20th year of life) presented on average with an higher cataract index (2.06 +/- 1.67) compared to patients with late manifestation (0.61 +/- 0.44), but equivalent duration of RP. The evaluation system offers a reliable and reproducible method for measuring PSC density and extension in RP patients. The method can serve as a useful tool for documenting PSC development and help to define the indications for cataract surgery in RP.

  13. Control of phosphorothioate stereochemistry substantially increases the efficacy of antisense oligonucleotides.

    PubMed

    Iwamoto, Naoki; Butler, David C D; Svrzikapa, Nenad; Mohapatra, Susovan; Zlatev, Ivan; Sah, Dinah W Y; Meena; Standley, Stephany M; Lu, Genliang; Apponi, Luciano H; Frank-Kamenetsky, Maria; Zhang, Jason Jingxin; Vargeese, Chandra; Verdine, Gregory L

    2017-09-01

    Whereas stereochemical purity in drugs has become the standard for small molecules, stereoisomeric mixtures containing as many as a half million components persist in antisense oligonucleotide (ASO) therapeutics because it has been feasible neither to separate the individual stereoisomers, nor to synthesize stereochemically pure ASOs. Here we report the development of a scalable synthetic process that yields therapeutic ASOs having high stereochemical and chemical purity. Using this method, we synthesized rationally designed stereopure components of mipomersen, a drug comprising 524,288 stereoisomers. We demonstrate that phosphorothioate (PS) stereochemistry substantially affects the pharmacologic properties of ASOs. We report that Sp-configured PS linkages are stabilized relative to Rp, providing stereochemical protection from pharmacologic inactivation of the drug. Further, we elucidated a triplet stereochemical code in the stereopure ASOs, 3'-SpSpRp, that promotes target RNA cleavage by RNase H1 in vitro and provides a more durable response in mice than stereorandom ASOs.

  14. Generation of accurate peptide retention data for targeted and data independent quantitative LC-MS analysis: Chromatographic lessons in proteomics.

    PubMed

    Krokhin, Oleg V; Spicer, Vic

    2016-12-01

    The emergence of data-independent quantitative LC-MS/MS analysis protocols further highlights the importance of high-quality reproducible chromatographic procedures. Knowing, controlling and being able to predict the effect of multiple factors that alter peptide RP-HPLC separation selectivity is critical for successful data collection for the construction of ion libraries. Proteomic researchers have often regarded RP-HPLC as a "black box", while vast amount of research on peptide separation is readily available. In addition to obvious parameters, such as the type of ion-pairing modifier, stationary phase and column temperature, we describe the "mysterious" effects of gradient slope, column size and flow rate on peptide separation selectivity. Retention time variations due to these parameters are governed by the linear solvent strength (LSS) theory on a peptide level by the value of its slope S in the basic LSS equation-a parameter that can be accurately predicted. Thus, the application of shallower gradients, higher flow rates, or smaller columns will each increases the relative retention of peptides with higher S-values (long species with multiple positively charged groups). Simultaneous changes to these parameters that each drive shifts in separation selectivity in the same direction should be avoided. The unification of terminology represents another pressing issue in this field of applied proteomics that should be addressed to facilitate further progress. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Ratio manipulating spectrophotometry versus chemometry as stability indicating methods for cefquinome sulfate determination.

    PubMed

    Yehia, Ali M; Arafa, Reham M; Abbas, Samah S; Amer, Sawsan M

    2016-01-15

    Spectral resolution of cefquinome sulfate (CFQ) in the presence of its degradation products was studied. Three selective, accurate and rapid spectrophotometric methods were performed for the determination of CFQ in the presence of either its hydrolytic, oxidative or photo-degradation products. The proposed ratio difference, derivative ratio and mean centering are ratio manipulating spectrophotometric methods that were satisfactorily applied for selective determination of CFQ within linear range of 5.0-40.0 μg mL(-1). Concentration Residuals Augmented Classical Least Squares was applied and evaluated for the determination of the cited drug in the presence of its all degradation products. Traditional Partial Least Squares regression was also applied and benchmarked against the proposed advanced multivariate calibration. Experimentally designed 25 synthetic mixtures of three factors at five levels were used to calibrate and validate the multivariate models. Advanced chemometrics succeeded in quantitative and qualitative analyses of CFQ along with its hydrolytic, oxidative and photo-degradation products. The proposed methods were applied successfully for different pharmaceutical formulations analyses. These developed methods were simple and cost-effective compared with the manufacturer's RP-HPLC method. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Influence of cooking on anthocyanins in black rice (Oryza sativa L. japonica var. SBR).

    PubMed

    Hiemori, Miki; Koh, Eunmi; Mitchell, Alyson E

    2009-03-11

    The composition and thermal stability of anthocyanins in black rice (Oryza sativa L. japonica var. SBR) produced in California were investigated. Six anthocyanin pigments were identified and quantified by high performance liquid chromatography using photo diode-array detection (HPLC-PDA) and electrospray ionization mass spectrometry [LC-(ESI)MS/MS]. The predominant anthocyanins are cyanidin-3-glucoside (572.47 microg/g; 91.13% of total) and peonidin-3-glucoside (29.78 microg/g; 4.74% of total). Minor constituents included three cyanidin-dihexoside isomers and one cyanidin hexoside. Thermal stability of anthocyanins was assessed in rice cooked using a rice cooker, pressure cooker, or on a gas range. All cooking methods caused significant (P < 0.001) decreases in the anthocyanins identified. Pressure cooking resulted in the greatest loss of cyanidin-3-glucoside (79.8%) followed by the rice cooker (74.2%) and gas range (65.4%). Conversely, levels of protocatechuic acid increased 2.7 to 3.4 times in response to all cooking methods. These findings indicate that cooking black rice results in the thermal degradation of cyanidin-3-glucoside and concomitant production of protocatechuic acid.

  17. Simultaneous determination of diclofenac potassium and methocarbamol in ternary mixture with guaifenesin by reversed phase liquid chromatography.

    PubMed

    Elkady, Ehab F

    2010-09-15

    New, simple, rapid and precise reversed phase liquid chromatographic (RP-LC) method has been developed for the simultaneous determination of diclofenac potassium (DP) and methocarbamol (MT) in ternary mixture with guaifenesin (GF), degradation product of methocarbamol. Chromatographic separation was achieved on a Symmetry Waters C18 column (150 mm x 4. 6mm, 5 microm). Gradient elution based on phosphate buffer pH (8)-acetonitrile at a flow rate of 1 mL min(-1) was applied. The UV detector was operated at 282 nm for DP and 274 nm for MT and GF. Linearity, accuracy and precision were found to be acceptable over the concentration ranges of 0.05-16, 0.5-160 and 0.5-160 microg mL(-1) for DP, MT and GF, respectively. The optimized method proved to be specific, robust and accurate for the quality control of the cited drugs in pharmaceutical preparation. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  18. Liquid chromatographic and ultraviolet spectrophotometric determination of bevantolol and hydrochlorothiazide in feeds.

    PubMed

    Spurlock, C H; Schneider, H G

    1984-01-01

    Separate assay methods have been developed for the 2 components of an 80 + 20 drug blend of bevantolol and hydrochlorothiazide (HCT) in admixtures with animal feed. Drug/diet admixtures are extracted with methanol for reverse phase ion-pair liquid chromatographic (LC) assay of bevantolol, and with acetonitrile for ultraviolet spectrophotometric assay of HCT. Bevantolol, a cardioselective beta blocker, is separated from soluble feed components with an RP-18 column, using methanol-water-acetic acid (60 + 40 + 1) containing 0. 005M octane-sulfonic acid, sodium salt, as ion-pairing reagent. HCT is determined spectrophotometrically in acetonitrile extracts, using a suitable blank extract as reference. Average recovery of HCT from an admixture of 0.5 mg blend/g diet is 94.5% +/- 4.3 RSD and at 2.0 mg/g, 101.5% +/- 3.5 RSD. Bevantolol recovery from the same admixtures is 101.8% +/- 2.7 RSD and 99.0% +/- 3.5 RSD, respectively, using the method as described.

  19. Determination of ragaglitazar, a novel dual acting peroxisome proliferator-activated receptor (PPAR) alpha and -gamma agonist, in human plasma by high-performance liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Andersen, Michael P; Nielsen, Karin K

    2003-05-05

    A sensitive and specific LC/MS/MS method has been developed and validated for determination of ragaglitazar (NNC 61-0029 or DRF 2725) in human plasma. After solid-phase extraction (SPEC((R)) PLUS C(8)) of plasma, separation was performed on a Symmetry Shield RP8 column (mobile phase: acetonitrile: 10 mM ammonium acetate, pH 5.6 (40:60 v/v)). Two ranges were validated having LLOQs of either 0.500 or 100 ng/ml and linearity up to either 500 or 50000 ng/ml. The intra-assay precision and accuracy were 1.1% to 15.7% and 85.8% to 118.2% (range 0.500-500 ng/ml) and 2.0% to 8.8% and 92.9% to 104.8% (range 100-50000 ng/ml). The method was applied for determination of ragaglitazar in plasma from phase 1 and 2 clinical studies.

  20. Immunoaffinity column cleanup with liquid chromatography using postcolumn bromination for the determination of aflatoxins in black and white sesame seed: single-laboratory validation.

    PubMed

    Liu, Guihua; Zhu, Zhou; Cheng, Jinquan; Senyuva, Hamide Z

    2012-01-01

    A single-laboratory validation was conducted to establish the effectiveness of an immunoaffinity column cleanup procedure followed by LC with fluorescence detection for the determination of aflatoxins B1, B2, G1, and G2 in sesame seeds. The sample is homogenized with 50% water (w/w) to form a slurry, then the test portion is extracted with methanol-water (60 + 40, v/v) using a high-speed blender. The sample extract is filtered, diluted with 15% Tween 20 in phosphate-buffered saline solution, and applied to an immunoaffinity column. Aflatoxins are removed with neat methanol, then directly determined by RP-LC with fluorescence detection using postcolumn bromination (Kobra cell). Test portions of blank white sesame seed slurry were spiked with a mixture of aflatoxins to give total levels of 4 and 10 microg/kg. Recoveries for individual and total aflatoxins ranged from 92.7 to 110.3% for spiked samples. Based on results for spiked sesame paste (triplicates at two levels), the RSD for repeatability (RSD(r)) averaged 1.1% for total aflatoxins and 1.4% for aflatoxin B1. The method was demonstrated to be applicable to naturally contaminated samples of black and white sesame seeds obtained from local markets in China.

  1. Assessing the correlation between mutant rhodopsin stability and the severity of retinitis pigmentosa

    PubMed Central

    McKeone, Richard; Wikstrom, Matthew; Kiel, Christina

    2014-01-01

    Purpose Following a previous study that demonstrated a correlation between rhodopsin stability and the severity of retinitis pigmentosa (RP), we investigated whether predictions of severity can be improved with a regional analysis of this correlation. The association between changes to the stability of the protein and the relative amount of rhodopsin reaching the plasma membrane was assessed. Methods Crystallography-based estimations of mutant rhodopsin stability were compared with descriptions in the scientific literature of the visual function of mutation carriers to determine the extent of associations between rhodopsin stability and clinical phenotype. To test the findings of this analysis, three residues of a green fluorescent protein (GFP) tagged rhodopsin plasmid were targeted with site-directed random mutagenesis to generate mutant variants with a range of stability changes. These plasmids were transfected into HEK-293 cells, and then flow cytometry was used to measure rhodopsin on the cells’ plasma membrane. The GFP signal was used to measure the ratio between this membrane-bound rhodopsin and total cellular rhodopsin. FoldX stability predictions were then compared with the surface staining data and clinical data from the database to characterize the relationship between rhodopsin stability, the severity of RP, and the expression of rhodopsin at the cell surface. Results There was a strong linear correlation between the scale of the destabilization of mutant variants and the severity of retinal disease. A correlation was also seen in vitro between stability and the amount of rhodopsin at the plasma membrane. Rhodopsin is drastically reduced on the surface of cells transfected with variants that differ in their inherent stability from the wild-type by more than 2 kcal/mol. Below this threshold, surface levels are closer to those of the wild-type. Conclusions There is a correlation between the stability of rhodopsin mutations and disease severity and levels of membrane-bound rhodopsin. Measuring membrane-bound rhodopsin with flow cytometry could improve prognoses for poorly characterized mutations and could provide a platform for measuring the effectiveness of treatments. PMID:24520188

  2. Determination of osthol and its metabolites in a phase I reaction system and the Caco-2 cell model by HPLC-UV and LC-MS/MS

    PubMed Central

    Yuan, Zhenting; Xu, Haiyan; Wang, Ke; Zhao, Zhonghua; Hu, Ming

    2012-01-01

    A straightforward and sensitive reversed-phase high-performance liquid chromatography (HPLC) assay was developed and validated for the analysis of osthol and its phase I metabolites (internal standard: umbelliferone). The method was validated for the determination of osthol with respect to selectivity, precision, linearity, limit of detection, recovery, and stability. The linear response range was 0.47 ~ 60 μM, and the average recoveries ranged from 98 to 101%. The inter-day and intra-day relative standard deviations were both less than 5%. Using this method, we showed that more than 80% of osthol was metabolized in 20 min in a phase I metabolic reaction system. Transport experiments in the Caco-2 cell culture model indicated that osthol was easily absorbed with high absorptive permeability (>10×10-6 cm/sec). The permeability did not display concentration-dependence or vectorial-dependence and is mildly temperature sensitive (activation energy less than 10 Kcal/mole), indicating passive mechanism of transport. When analyzed by LC-MS/MS, five metabolites were detected in a phase I reaction system and in the receiver side of a modified Caco-2 cell model, which was supplemented with the phase I reaction system. The major metabolites appeared to be desmethyl-osthol and multiple isomers of dehydro-osthol. In conclusion, a likely cause of poor osthol bioavailability is rapid phase I metabolism via the cytochrome P-450 pathways. PMID:19304430

  3. LOX/hydrocarbon rocket engine analytical design methodology development and validation. Volume 2: Appendices

    NASA Technical Reports Server (NTRS)

    Niiya, Karen E.; Walker, Richard E.; Pieper, Jerry L.; Nguyen, Thong V.

    1993-01-01

    This final report includes a discussion of the work accomplished during the period from Dec. 1988 through Nov. 1991. The objective of the program was to assemble existing performance and combustion stability models into a usable design methodology capable of designing and analyzing high-performance and stable LOX/hydrocarbon booster engines. The methodology was then used to design a validation engine. The capabilities and validity of the methodology were demonstrated using this engine in an extensive hot fire test program. The engine used LOX/RP-1 propellants and was tested over a range of mixture ratios, chamber pressures, and acoustic damping device configurations. This volume contains time domain and frequency domain stability plots which indicate the pressure perturbation amplitudes and frequencies from approximately 30 tests of a 50K thrust rocket engine using LOX/RP-1 propellants over a range of chamber pressures from 240 to 1750 psia with mixture ratios of from 1.2 to 7.5. The data is from test configurations which used both bitune and monotune acoustic cavities and from tests with no acoustic cavities. The engine had a length of 14 inches and a contraction ratio of 2.0 using a 7.68 inch diameter injector. The data was taken from both stable and unstable tests. All combustion instabilities were spontaneous in the first tangential mode. Although stability bombs were used and generated overpressures of approximately 20 percent, no tests were driven unstable by the bombs. The stability instrumentation included six high-frequency Kistler transducers in the combustion chamber, a high-frequency Kistler transducer in each propellant manifold, and tri-axial accelerometers. Performance data is presented, both characteristic velocity efficiencies and energy release efficiencies, for those tests of sufficient duration to record steady state values.

  4. N-glycosylation of plant recombinant pharmaceuticals.

    PubMed

    Bardor, Muriel; Cabrera, Gleysin; Stadlmann, Johannes; Lerouge, Patrice; Cremata, José A; Gomord, Véronique; Fitchette, Anne-Catherine

    2009-01-01

    N-glycosylation is a maturation event necessary for the correct function, efficiency, and stability of a high number of biopharmaceuticals. This chapter presented here proposes various methods to determine whether, how, and where a plant pharmaceutical is N-glycosylated. These methods rely on blot detection with glycan-specific probes, specific deglycosylation of glycoproteins followed by mass spectrometry, N-glycan profile analysis, and glycopeptide identification by LC-MS.

  5. Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum.

    PubMed

    Chen, Lin; Xiao, Qingqing; Zhang, Xian; Yang, Jin

    2016-03-20

    2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). Copyright © 2015 Elsevier B.V. All rights reserved.

  6. A 500-600 MHz GaN power amplifier with RC-LC stability network

    NASA Astrophysics Data System (ADS)

    Ma, Xinyu; Duan, Baoxing; Yang, Yintang

    2017-08-01

    A 500-600 MHz high-efficiency, high-power GaN power amplifier is designed and realized on the basis of the push-pull structure. The RC-LC stability network is proposed and applied to the power amplifier circuit for the first time. The RC-LC stability network can significantly reduce the high gain out the band, which eliminates the instability of the power amplifier circuit. The developed power amplifier exhibits 58.5 dBm (700 W) output power with a 17 dB gain and 85% PAE at 500-600 MHz, 300 μs, 20% duty cycle. It has the highest PAE in P-band among the products at home and abroad. Project supported by the National Key Basic Research Program of China (No. 2014CB339901).

  7. An efficient HPLC method for the analysis of isomeric purity of technetium-99m-exametazime and identity confirmation using LC-MS.

    PubMed

    Vanderghinste, D; Van Eeckhoudt, M; Terwinghe, C; Mortelmans, L; Bormans, G M; Verbruggen, A M; Vanbilloen, H P

    2003-08-08

    99mTc-exametazime (99mTc-d,l-HMPAO, 99mTc-d,l-hexamethylpropyleneamine oxime) is a neutral rather unstable complex of short-lived 99mTc (t(1/2)=6 h) with the d,l-isomer (mixture of D,D- and L,L-isomers) of a bis-amine bis-oxime tetraligand. It is widely used for measurement of regional cerebral perfusion in nuclear medicine. The meso-isomer (D,L-form) should not be present in a preparation as it is not retained in brain and thus does not provide clinically useful information. Meso-HMPAO is removed from the ligand during the synthesis procedure by repeated recrystallization, but can still be present as impurity in d,l-isomer. Due to the lack of a suitable chromatographic method for analysis of the isomeric purity of 99mTc-exametazime preparations, United States Pharmacopoeia 25 (USP 25) prescribes a biological test in rats for quality control purpose. In this study, we developed a suitable high-performance liquid chromatography (HPLC) method which allows to demonstrate the relative amounts of d,l- and meso-isomer in 99mTc-exametazime and so obviates the need for a biodistribution test in animals as part of the quality control. Due to the low concentrations in which 99mTc-d,l-HMPAO is obtained (typically 2-6 ng/ml), confirmation of the identity of 99mTc-d,l-HMPAO in the monograph of the European Pharmacopoeia is now performed only indirectly by TLC and assessment of its retention time on RP-HPLC. To investigate the potential of radio-LC-MS for assessment of the identity of 99mTc-exametazime, 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO prepared using a Tc-rich eluate were analyzed using a radio-LC-MS system equipped with a time-of-flight mass spectrometer with electrospray ionization. The main peak in the radiometric channel coincided with the molecular ion mass of 99mTc-d,l-HMPAO in the mass spectrometer channel and the measured accurate mass differed only by 0.26 ppm from the theoretical mass. The identity of 99mTc-meso-HMPAO was also confirmed. Thus, radio-LC-MS allowed to obtain strong evidence for the structure of 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO at nanomolar concentration. It is concluded that radio-LC-MS can become a sensitive aid in quality control of "no carrier added" radiopharmaceutical preparations.

  8. Self-assembled lecithin/chitosan nanoparticles for oral insulin delivery: preparation and functional evaluation

    PubMed Central

    Liu, Liyao; Zhou, Cuiping; Xia, Xuejun; Liu, Yuling

    2016-01-01

    Purpose Here, we investigated the formation and functional properties of self-assembled lecithin/chitosan nanoparticles (L/C NPs) loaded with insulin following insulin–phospholipid complex preparation, with the aim of developing a method for oral insulin delivery. Methods Using a modified solvent-injection method, insulin-loaded L/C NPs were obtained by combining insulin–phospholipid complexes with L/C NPs. The nanoparticle size distribution was determined by dynamic light scattering, and morphologies were analyzed by cryogenic transmission electron microscopy. Fourier transform infrared spectroscopy analysis was used to disclose the molecular mechanism of prepared insulin-loaded L/C NPs. Fast ultrafiltration and a reversed-phase high-performance liquid chromatography assay were used to separate free insulin from insulin entrapped in the L/C NPs, as well as to measure the insulin-entrapment and drug-loading efficiencies. The in vitro release profile was obtained, and in vivo hypoglycemic effects were evaluated in streptozotocin-induced diabetic rats. Results Our results indicated that insulin-containing L/C NPs had a mean size of 180 nm, an insulin-entrapment efficiency of 94%, and an insulin-loading efficiency of 4.5%. Cryogenic transmission electron microscopy observations of insulin-loaded L/C NPs revealed multilamellar structures with a hollow core, encircled by several bilayers. In vitro analysis revealed that insulin release from L/C NPs depended on the L/C ratio. Insulin-loaded L/C NPs orally administered to streptozotocin-induced diabetic rats exerted a significant hypoglycemic effect. The relative pharmacological bioavailability following oral administration of L/C NPs was 6.01%. Conclusion With the aid of phospholipid-complexation techniques, some hydrophilic peptides, such as insulin, can be successfully entrapped into L/C NPs, which could improve oral bioavailability, time-dependent release, and therapeutic activity. PMID:26966360

  9. Collisionless Isotropization of the Solar-Wind Protons by Compressive Fluctuations and Plasma Instabilities

    NASA Astrophysics Data System (ADS)

    Verscharen, D.; Chandran, B. D. G.; Klein, K. G.; Quataert, E.

    2016-12-01

    Compressive fluctuations are a minor yet significant component of astrophysical plasma turbulence. In the solar wind, long-wavelength compressive slow-mode fluctuations lead to changes in β∥p ≡ 8πnpkBT∥p/B2 and in Rp ≡ T⊥p/T∥p, where T⊥p and T∥p are the perpendicular and parallel temperatures of the protons, B is the magnetic field strength, and np is the proton density. If the amplitude of the compressive fluctuations is large enough, Rp crosses one or more instability thresholds for anisotropy-driven micro-instabilities. The enhanced field fluctuations from these micro-instabilities scatter the protons so as to reduce the anisotropy of the pressure tensor, driving the average value of Rp away from the marginal stability boundary until the fluctuating value of Rp stops crossing the boundary. We model this "fluctuating-anisotropy effect" using linear Vlasov-Maxwell theory to describe the large-scale compressive fluctuations. We show that this effect can explain why, in the nearly collisionless solar wind, the average value of Rp is close to unity.

  10. Simultaneous quantitative analyses of indole and oxindole alkaloids of Uncaria Hook in rat plasma and brain after oral administration of the traditional Japanese medicine Yokukansan using high-performance liquid chromatography with tandem mass spectrometry.

    PubMed

    Kushida, Hirotaka; Fukutake, Miwako; Tabuchi, Masahiro; Katsuhara, Takao; Nishimura, Hiroaki; Ikarashi, Yasushi; Kanitani, Masanao; Kase, Yoshio

    2013-12-01

    Uncaria Hook (UH) alkaloids are involved in the beneficial effects of Yokukansan. However, the pharmacokinetics of UH alkaloids after oral administration of Yokukansan has not yet been sufficiently investigated. Therefore, we developed and validated a sensitive and specific high-performance liquid chromatography with tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantitation of seven UH alkaloids (corynoxeine, isocorynoxeine, rhynchophylline, isorhynchophylline, hirsutine, hirsuteine and geissoschizine methyl ether) in rat plasma and brain. After protein precipitation with acetonitrile, chromatographic separation was performed using an Ascentis Express RP-amide column, with gradient elution with 0.2% formic acid and acetonitrile at 0.3 mL/min. All analytes in the plasma and brain showed good linearity over a wide concentration range (r > 0.995). Intra-day and inter-day variations of each constituent were 8.6 and 8.0% or less in the plasma, and 14.9 and 15.0% or less in the brain, respectively. The validated LC/MS/MS method was applied in the pharmacokinetic studies of UH alkaloids after oral administration of Yokukansan to rats. In the plasma, rhynchophylline, hirsutine, hirsuteine and geissoschizine methyl ether were detected, but only geissoschizine methyl ether was detected in the brain. These results suggest that geissoschizine methyl ether is an important constituent of the pharmacological effects of Yokukansan. Copyright © 2013 John Wiley & Sons, Ltd.

  11. Determination of esters in glycerol phase after transesterification of vegetable oil.

    PubMed

    Hájek, Martin; Skopal, Frantisek; Kwiecien, Jirí; Cernoch, Michal

    2010-06-30

    In biodiesel production, glycerol is formed as a side product and it is contained in the glycerol phase. This phase contains (besides glycerol): water, soaps, alcohol, traces of catalyst and glycerides and the remaining esters. In this paper, a new method for the determination of esters in the glycerol phase is introduced. The determination enables the minimization of the losses of biodiesel within the production process. It is based on the gradient RP-LC method (water and acetonitrile) with refractometric detection. The analysis is easy and the samples do not need any treatment (only dilution by water) and has a low detection limit. The results of this method were compared with the results of two other published methods: isocratic HPLC and GC. The disadvantage of these two methods is that they need extensive treatment of the sample, which takes many hours, and they are able to determine only the sum of esters. The new method is reliable, much faster and able to differentiate esters of almost each higher fatty acid (e.g. linoleic, linolenic, strearic alkyl ester) in the glycerol phase. Copyright 2010 Elsevier B.V. All rights reserved.

  12. In vitro antioxidant activity of rice protein affected by alkaline degree and gastrointestinal protease digestion.

    PubMed

    Liu, Ye; Wang, Zhengxuan; Li, Hui; Liang, Mingcai; Yang, Lin

    2016-12-01

    To elucidate whether and how alkali treatment, which is a common process for rice protein (RP) extraction, affects antioxidant activity of RP, the different degree of alkali (from 0.1% to 0.4% of NaOH) was used to extract RP (RP-1, RP-2, RP-3, RP-4). The antioxidant capacities of scavenging free radicals [2,2'-azinobis(3-ethylbenzothiazoline-6-sulfonic acid] diammonium salt, ABTS; 1,1-diphenyl-2-picrylhydrazyl, DPPH), chelating metals (iron, copper) and reducing power investigated in the hydrolysates of RPs (RP-1, RP-2, RP-3, RP-4) during in vitro pepsin-pancreatin digestion were effectively affected by alkali treatment. The present study demonstrated that the weakest antioxidant responses to ABTS radical-scavenging activity, DPPH radical-scavenging activity, iron chelating activity, copper chelating activity and reducing power were produced by RP-4 extracted by the highest alkali proportion (0.4% NaOH). The present study indicates that antioxidant capacity of RP could be more readily depressed by strict alkali degree and affected by gastrointestinal proteases. Results suggest that alkali extraction is a vital process to regulate the antioxidant activity of RP through modifying the compositions of amino acids, which are dependent on alkali magnitude. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  13. Biomechanical assessment and 3D finite element analysis of the treatment of tibial fractures using minimally invasive percutaneous plates

    PubMed Central

    Hu, Xin-Jia; Wang, Hua

    2017-01-01

    The aim of the present study was to investigate the biomechanical effects of varying the length of a limited contact-dynamic compression plate (LC-DCP) and the number and position of screws on middle tibial fractures, and to provide biomechanical evidence regarding minimally invasive plate osteosynthesis (MIPO). For biomechanical testing, 60 tibias from cadavers (age at mortality, 20–40 years) were used to create middle and diagonal fracture models without defects. Tibias were randomly grouped and analyzed by biomechanic and three-dimensional (3D) finite element analysis. The differences among LC-DCPs of different lengths (6-, 10- and 14-hole) with 6 screws, 14-hole LC-DCPs with different numbers of screws (6, 10 and 14), and 14-hole LC-DCPs with 6 screws at different positions with regard to mechanical characteristics, including compressing, torsion and bending, were examined. The 6-hole LC-DCP had greater vertical compression strain compared with the 10- and 14-hole LC-DCPs (P<0.01), and the 14-hole LC-DCP had greater lateral strain than the 6- and 10-hole LC-DCPs (P<0.01). Furthermore, significant differences in torque were observed among the LC-DPs of different lengths (P<0.01). For 14-hole LC-DCPs with different numbers of screws, no significant differences in vertical strain, lateral strain or torque were detected (P>0.05). However, plates with 14 screws had greater vertical strain compared with those fixed with 6 or 10 screws (P<0.01). For 4-hole LC-DCPs with screws at different positions, vertical compression strain values were lowest for plates with screws at positions 1, 4, 7, 8, 11 and 14 (P<0.01). The lateral strain values and vertical strain values for plates with screws at positions 1, 3, 6, 9, 12 and 14 were significantly lower compared with those at the other positions (P<0.01), and torque values were also low. Thus, the 14-hole LC-DCP was the most stable against vertical compression, torsion and bending, and the 6-hole LC-DCP was the least stable. However, the use of 14 screws with a 14-hole LC-DCP provided less stability against bending than did 6 or 10 screws. Furthermore, fixation with distributed screws, in which some screws were close to the fracture line, provided good stability against compression and torsion, while fixation with screws at the ends of the LC-DCP provided poor stability against bending, compressing and torsion. PMID:28781632

  14. Reduction in PSA messenger-RNA expression and clinical recurrence in patients with prostatic cancer undergoing neoadjuvant therapy before radical prostatectomy

    PubMed Central

    Grasso, Marco; Lania, Caterina; Blanco, Salvatore; Baruffi, Marco; Mocellin, Simone

    2004-01-01

    Background We assessed the incidence of micro-metastases at surgical margins (SM) and pelvic lymph nodes (LN) in patients submitted to radical retropubic prostatectomy (RP) after neoadjuvant therapy (NT) or to RP alone. We compared traditional staging to molecular detection of PSA using Taqman-based quantitative real-time PCR (qrt-PCR) never used before for this purpose. Methods 29 patients were assigned to NT plus RP (arm A) or RP alone (arm B). Pelvic LN were dissected for qrt-PCR analysis, together with right and left lateral SM. Results 64,3% patients of arm B and 26.6% of arm A had evidence of PSA mRNA expression in LN and/or SM. 17,2% patients, all of arm B, had biochemical recurrence. Conclusions Qrt-PCR may be more sensitive, compared to conventional histology, in identifying presence of viable prostate carcinoma cells in SM and LN. Gene expression of PSA in surgical periprostatic samples might be considered as a novel and reliable indicator of minimal residual disease after NT. PMID:15104791

  15. Determination of supplier-to-supplier and lot-to-lot variability in glycation of recombinant human serum albumin expressed in Oryza sativa.

    PubMed

    Frahm, Grant E; Smith, Daryl G S; Kane, Anita; Lorbetskie, Barry; Cyr, Terry D; Girard, Michel; Johnston, Michael J W

    2014-01-01

    The use of different expression systems to produce the same recombinant human protein can result in expression-dependent chemical modifications (CMs) leading to variability of structure, stability and immunogenicity. Of particular interest are recombinant human proteins expressed in plant-based systems, which have shown particularly high CM variability. In studies presented here, recombinant human serum albumins (rHSA) produced in Oryza sativa (Asian rice) (OsrHSA) from a number of suppliers have been extensively characterized and compared to plasma-derived HSA (pHSA) and rHSA expressed in yeast (Pichia pastoris and Saccharomyces cerevisiae). The heterogeneity of each sample was evaluated using size exclusion chromatography (SEC), reversed-phase high-performance liquid chromatography (RP-HPLC) and capillary electrophoresis (CE). Modifications of the samples were identified by liquid chromatography-mass spectrometry (LC-MS). The secondary and tertiary structure of the albumin samples were assessed with far U/V circular dichroism spectropolarimetry (far U/V CD) and fluorescence spectroscopy, respectively. Far U/V CD and fluorescence analyses were also used to assess thermal stability and drug binding. High molecular weight aggregates in OsrHSA samples were detected with SEC and supplier-to-supplier variability and, more critically, lot-to-lot variability in one manufactures supplied products were identified. LC-MS analysis identified a greater number of hexose-glycated arginine and lysine residues on OsrHSA compared to pHSA or rHSA expressed in yeast. This analysis also showed supplier-to-supplier and lot-to-lot variability in the degree of glycation at specific lysine and arginine residues for OsrHSA. Both the number of glycated residues and the degree of glycation correlated positively with the quantity of non-monomeric species and the chromatographic profiles of the samples. Tertiary structural changes were observed for most OsrHSA samples which correlated well with the degree of arginine/lysine glycation. The extensive glycation of OsrHSA from multiple suppliers may have further implications for the use of OsrHSA as a therapeutic product.

  16. The cervical end of an occipitocervical fusion: a biomechanical evaluation of 3 constructs. Laboratory investigation.

    PubMed

    Finn, Michael A; Fassett, Daniel R; Mccall, Todd D; Clark, Randy; Dailey, Andrew T; Brodke, Darrel S

    2008-09-01

    Stabilization with rigid screw/rod fixation is the treatment of choice for craniocervical disorders requiring operative stabilization. The authors compare the relative immediate stiffness for occipital plate fixation in concordance with transarticular screw fixation (TASF), C-1 lateral mass and C-2 pars screw (C1L-C2P), and C-1 lateral mass and C-2 laminar screw (C1L-C2L) constructs, with and without a cross-link. Ten intact human cadaveric spines (Oc-C4) were prepared and mounted in a 7-axis spine simulator. Each specimen was precycled and then tested in the intact state for flexion/extension, lateral bending, and axial rotation. Motion was tracked using the OptoTRAK 3D tracking system. The specimens were then destabilized and instrumented with an occipital plate and TASF. The spine was tested with and without the addition of a cross-link. The C1L-C2P and C1L-C2L constructs were similarly tested. All constructs demonstrated a significant increase in stiffness after instrumentation. The C1L-C2P construct was equivalent to the TASF in all moments. The C1L-C2L was significantly weaker than the C1L-C2P construct in all moments and significantly weaker than the TASF in lateral bending. The addition of a cross-link made no difference in the stiffness of any construct. All constructs provide significant immediate stability in the destabilized occipitocervical junction. Although the C1L-C2P construct performed best overall, the TASF was similar, and either one can be recommended. Decreased stiffness of the C1L-C2L construct might affect the success of clinical fusion. This construct should be reserved for cases in which anatomy precludes the use of the other two.

  17. Effects and mechanism of ultrasound pretreatment on rapeseed protein enzymolysis.

    PubMed

    Jin, Jian; Ma, Haile; Wang, Weiwei; Luo, Min; Wang, Bei; Qu, Wenjuan; He, Ronghai; Owusu, John; Li, Yunliang

    2016-03-15

    The disadvantages which stem from the use of traditional enzymolysis of protein has necessitated the need to employ sweeping frequency and pulsed ultrasound (SFPU) in the pretreatment of rapeseed protein prior to proteolysis in order to bring about improvement in enzymolysis efficiency. Further, in order to determine the mechanism of ultrasound-accelerated enzymolysis of RP, the effects of SFPU on the kinetics, thermodynamics, molecular conformation and microstructure of RP were investigated. Kinetic studies showed that SFPU pretreatment on RP improved enzymolysis by decreasing the apparent constant KM significantly (P < 0.05) by 32.8% and reducing the thermodynamic parameters Ea , ΔH and ΔS by 16.6%, 17.7% and 9.2% respectively. Fluorescence spectra revealed that SFPU pretreatment induced molecular unfolding, causing more hydrophobic groups and regions inside the molecules to be exposed to the outside. Circular dichroism analysis indicated that SFPU pretreatment decreased the α-helix content by 16.1% and increased the random coil content by 3.6%. In addition, scanning electron microscopy showed that SFPU pretreatment increased the specific surface area of RP. Ultrasound pretreatment is an efficient method in RP proteolysis to produce peptides through its impact on the molecular conformation and microstructure of proteins. © 2015 Society of Chemical Industry.

  18. MS(n) , LC-MS-TOF and LC-PDA studies for identification of new degradation impurities of bupropion.

    PubMed

    Bansal, Rohit; Saini, Balraj; Bansal, Yogita; Bansal, Gulshan

    2013-11-01

    Three new degradation impurities of bupropion were characterized through high performance liquid chromatography coupled to photodiode array detection and to time-of-flight mass spectrometry. Bupropion was subjected to the ICH prescribed stress conditions. It degraded to seven impurities (I-VII) in alkaline hydrolytic conditions which were optimally resolved on an XTerra C18 column (250 × 4.6 mm, 5 µm) with a ternary mobile phase comprising ammonium formate (20 mm, pH 4.0), methanol and acetonitrile (75:10:15, v/v). The degradation impurities (III-V and VII) were characterized on the basis of mass fragmentation pattern of drug, accurate mass spectral and photodiode array data of the drug and degradation impurities. Compound V was found to be a known degradation impurity [1-hydroxy-1-(3-chlorophenyl)propan-2-one], whereas III, IV and VII were characterized as 2-hydroxy-2-(3'-chlorophenyl)-3,5,5-trimethylmorpholine, (2,4,4-trimethyl-1,3-oxazolidin-2-yl)(3-chlorophenyl)-methanone and 2-(3'-chlorophenyl)-3,5,5-trimethylmorphol-2-ene, respectively. Compound III was a known metabolite of the drug. This additional information on the degradation impurities can help in the development of a new stability-indicating assay method to monitor the stability of the drug product during its shelf-life as well as in development of a drug product with increased shelf-life. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Therapeutic Approaches for Botulinum Intoxication Targeting Degradation of the Light Chain

    DTIC Science & Technology

    2013-04-01

    SUBJECT TERMS Botulinum toxin , ubiquitin, chimeric toxin light chains, LcA, LcE, Yeast 2 hybrid, intracellular therapy. 16. SECURITY...Synaptic Research will develop dichain hybrids consisting of Clostridium botulinum toxin light chains (LCs) from serotypes A (long-lived) and E...stability to LCs of botulinum toxin can be assessed by mutation of dileucine residues and systematic deletion of residues from LcA-LcE chimeras to provide a

  20. Analysis of formononetin from black cohosh (Actaea racemosa).

    PubMed

    Jiang, B; Kronenberg, F; Balick, M J; Kennelly, E J

    2006-07-01

    Black cohosh has been widely used as an herbal medicine for the treatment of symptoms related to menopause in America and Europe during the past several decades, but the bioactive constituents are still unknown. Formononetin is an isoflavone with known estrogen-like activity. This compound was first reported to be isolated from black cohosh in 1985, but subsequent research in 2002 using HPLC-PDA and LC-MS revealed no evidence to show the presence of formononetin in 13 populations of American black cohosh. A more recent report published in 2004 claimed to detect formononetin in an extract of black cohosh rhizomes using a TLC-fluorescent densitometry method. To further resolve these conflicting reports, we analyzed black cohosh roots and rhizomes for the presence of formononetin, using a combined TLC, HPLC-PDA and LC-MS method. We examined both methanolic and aqueous methanolic black cohosh extracts by HPLC-PDA and LC-MS methods, and did not detect formononetin in any extracts. We further determined the limits of detection of formononetin by HPLC-PDA and LC-MS. Our experimental results indicated that the sensitivity and accuracy of the HPLC-PDA and LC-MS methods for the analysis of formononetin were slightly higher than those of the reported fluorescent method, suggesting that the HPLC-PDA and LC-MS methods were reliable for the analysis of formononetin from black cohosh. We also repeated the reported TLC method to concentrate two fractions from a modern black cohosh sample and an 86-year-old black cohosh sample, respectively, and then analyzed these two fractions for formononetin using the HPLC-PDA and LC-MS method instead of the fluorescent method. Formononetin was not detected by HPLC-PDA or LC-MS. From the results of the present study it is not reasonable to attribute the estrogen-like activity of black cohosh extracts to formononetin.

  1. A pipeline of spatio-temporal filtering for predicting the laterality of self-initiated fine movements from single trial readiness potentials.

    PubMed

    Zeid, Elias Abou; Sereshkeh, Alborz Rezazadeh; Chau, Tom

    2016-12-01

    In recent years, the readiness potential (RP), a type of pre-movement neural activity, has been investigated for asynchronous electroencephalogram (EEG)-based brain-computer interfaces (BCIs). Since the RP is attenuated for involuntary movements, a BCI driven by RP alone could facilitate intentional control amid a plethora of unintentional movements. Previous studies have attempted single trial classification of RP via spatial and temporal filtering methods, or by combining the RP with event-related desynchronization. However, RP feature extraction remains challenging due to the slow non-oscillatory nature of the potential, its variability among participants and the inherent noise in EEG signals. Here, we propose a participant-specific, individually optimized pipeline of spatio-temporal filtering (PSTF) to improve RP feature extraction for laterality prediction. PSTF applies band-pass filtering on RP signals, followed by Fisher criterion spatial filtering to maximize class separation, and finally temporal window averaging for feature dimension reduction. Optimal parameters are simultaneously found by cross-validation for each participant. Using EEG data from 14 participants performing self-initiated left or right key presses as well as two benchmark BCI datasets, we compared the performance of PSTF to two popular methods: common spatial subspace decomposition, and adaptive spatio-temporal filtering. On the BCI benchmark data sets, PSTF performed comparably to both existing methods. With the key press EEG data, PSTF extracted more discriminative features, thereby leading to more accurate (74.99% average accuracy) predictions of RP laterality than that achievable with existing methods. Naturalistic and volitional interaction with the world is an important capacity that is lost with traditional system-paced BCIs. We demonstrated a significant improvement in fine movement laterality prediction from RP features alone. Our work supports further study of RP-based BCI for intuitive asynchronous control of the environment, such as augmentative communication or wheelchair navigation.

  2. A pipeline of spatio-temporal filtering for predicting the laterality of self-initiated fine movements from single trial readiness potentials

    NASA Astrophysics Data System (ADS)

    Abou Zeid, Elias; Rezazadeh Sereshkeh, Alborz; Chau, Tom

    2016-12-01

    Objective. In recent years, the readiness potential (RP), a type of pre-movement neural activity, has been investigated for asynchronous electroencephalogram (EEG)-based brain-computer interfaces (BCIs). Since the RP is attenuated for involuntary movements, a BCI driven by RP alone could facilitate intentional control amid a plethora of unintentional movements. Previous studies have attempted single trial classification of RP via spatial and temporal filtering methods, or by combining the RP with event-related desynchronization. However, RP feature extraction remains challenging due to the slow non-oscillatory nature of the potential, its variability among participants and the inherent noise in EEG signals. Here, we propose a participant-specific, individually optimized pipeline of spatio-temporal filtering (PSTF) to improve RP feature extraction for laterality prediction. Approach. PSTF applies band-pass filtering on RP signals, followed by Fisher criterion spatial filtering to maximize class separation, and finally temporal window averaging for feature dimension reduction. Optimal parameters are simultaneously found by cross-validation for each participant. Using EEG data from 14 participants performing self-initiated left or right key presses as well as two benchmark BCI datasets, we compared the performance of PSTF to two popular methods: common spatial subspace decomposition, and adaptive spatio-temporal filtering. Main results. On the BCI benchmark data sets, PSTF performed comparably to both existing methods. With the key press EEG data, PSTF extracted more discriminative features, thereby leading to more accurate (74.99% average accuracy) predictions of RP laterality than that achievable with existing methods. Significance. Naturalistic and volitional interaction with the world is an important capacity that is lost with traditional system-paced BCIs. We demonstrated a significant improvement in fine movement laterality prediction from RP features alone. Our work supports further study of RP-based BCI for intuitive asynchronous control of the environment, such as augmentative communication or wheelchair navigation.

  3. Quantitation and Identification of Intact Major Milk Proteins for High-Throughput LC-ESI-Q-TOF MS Analyses.

    PubMed

    Vincent, Delphine; Elkins, Aaron; Condina, Mark R; Ezernieks, Vilnis; Rochfort, Simone

    2016-01-01

    Cow's milk is an important source of proteins in human nutrition. On average, cow's milk contains 3.5% protein. The most abundant proteins in bovine milk are caseins and some of the whey proteins, namely beta-lactoglobulin, alpha-lactalbumin, and serum albumin. A number of allelic variants and post-translationally modified forms of these proteins have been identified. Their occurrence varies with breed, individuality, stage of lactation, and health and nutritional status of the animal. It is therefore essential to have reliable methods of detection and quantitation of these proteins. Traditionally, major milk proteins are quantified using liquid chromatography (LC) and ultra violet detection method. However, as these protein variants co-elute to some degree, another dimension of separation is beneficial to accurately measure their amounts. Mass spectrometry (MS) offers such a tool. In this study, we tested several RP-HPLC and MS parameters to optimise the analysis of intact bovine proteins from milk. From our tests, we developed an optimum method that includes a 20-28-40% phase B gradient with 0.02% TFA in both mobile phases, at 0.2 mL/min flow rate, using 75°C for the C8 column temperature, scanning every 3 sec over a 600-3000 m/z window. The optimisations were performed using external standards commercially purchased for which ionisation efficiency, linearity of calibration, LOD, LOQ, sensitivity, selectivity, precision, reproducibility, and mass accuracy were demonstrated. From the MS analysis, we can use extracted ion chromatograms (EICs) of specific ion series of known proteins and integrate peaks at defined retention time (RT) window for quantitation purposes. This optimum quantitative method was successfully applied to two bulk milk samples from different breeds, Holstein-Friesian and Jersey, to assess differences in protein variant levels.

  4. Thermal stability of chemically bonded phases on silica gel by photoacoustic FT-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Kierys, A.; Pasieczna, S.; Ryczkowski, J.; Goworek, J.

    2006-11-01

    The temperature resistance of chemically bonded phases on commercial silica gel, LiChrosorb RP 2, RP 8, RP 18 and unmodified Si 60 were tested at different temperatures by photoacoustic FT-IR spectroscopy. The surface characteristics and possible degradation of hydrocarbon phase at higher temperatures were investigated by means of FT-IR/PAS technique. For a series of investigated samples heated up to 423 K, the FT-IR/PAS spectra are similar to those for initial silica samples. The most characteristic band for alkyl modified silica gel, i.e., RP 2, RP 8, and RP 18 was observed between 3200 cm-1 to 2800 cm-1 corresponding to various hydrocarbon species. The bands at 3745 cm-1, 3650 cm-1, and 3430 cm-1 observed in the photoacoustic FT-IR spectra may be ascribed to isolated silanol groups (Si-OH), geminal groups (Si-(OH)2) and hydrogen-bonded Si-OH groups, respectively. For all samples the intensity of the broad band in the region 3800 cm-1 to 3200 cm-1 decreases with the increasing temperature. The additional peak at 3745 cm-1 for chemically bonded long hydrocarbon chain, i.e., C18 and C8 after thermal treatment at 573 K is observed.

  5. Analysis of nicotine and cotinine in hair by on-line in-tube solid-phase microextraction coupled with liquid chromatography-tandem mass spectrometry as biomarkers of exposure to tobacco smoke.

    PubMed

    Inukai, Takehito; Kaji, Sanae; Kataoka, Hiroyuki

    2018-07-15

    Smoking not only increases the risk of lung cancer but is strongly related to the onset of cardiovascular disease. Particularly, passive smoking due to sidestream smoke is a critical public health problem. To assess active and passive exposure to tobacco smoke, we developed a simple and sensitive method, consisting of on-line in-tube solid phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS), to determine nicotine and its metabolite cotinine in hair samples. These compounds were separated within 5 min using a Polar-RP80A column and detected in the positive ion mode by multiple reaction monitoring. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Carboxen 1006 capillary column as an extraction device. The extracted compounds in the stationary phase on the inner wall of the capillary could be dissolved easily into the mobile phase and transferred to an LC column. Using the in-tube SPME LC-MS/MS method, the calibration curves were linear in the 5-1000 pg/mL ranges for nicotine and cotinine, and the detection limits (signal to noise ratio of 3) were 0.45 and 0.13 pg/mL, respectively. The intra-day and inter-day precisions were below 3.4% and 6.0% (n = 5), respectively. This method was utilized successfully to analyze pg/mg levels of nicotine and cotinine in 1 mg of hairs without interference peaks, and good recoveries were obtained. The concentration of cotinine in hair was two orders of magnitude lower than that of nicotine, but a good positive correlation was found between the concentrations of these compounds. This method can automate the extraction, concentration and analysis of samples, and is useful for the assessment of long-term exposure to tobacco smoke. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Photoalignment and resulting holographic vector grating formation in composites of low molecular weight liquid crystals and photoreactive liquid crystalline polymers

    NASA Astrophysics Data System (ADS)

    Sasaki, Tomoyuki; Shoho, Takashi; Goto, Kohei; Noda, Kohei; Kawatsuki, Nobuhiro; Ono, Hiroshi

    2015-08-01

    Polarization holographic gratings were formed in liquid crystal (LC) cells fabricated from a mixture of low molecular weight nematic LC and a photoreactive liquid crystalline polymer (PLCP) with 4-(4-methoxycinnamoyloxy)biphenyl side groups. The diffraction properties of the gratings were analyzed using theoretical models which were determined based on the polarization patterns of the polarization holography. The results demonstrated that vector gratings comprised of periodic orientation distributions of the LC molecule were induced in the cells based on the axis-selective photoreaction of the PLCP. The vector gratings were erased by applying a sufficiently high voltage to the cells and then were reformed with no hysteresis after the voltage was removed. This phenomenon suggested that the PLCP molecules were stabilized based on the axis-selective photocrosslink reaction and that the LC molecules were aligned by the photocrosslinked PLCP. This LC composite with axis-selective photoreactivity is useful for various optical applications, because of their stability, transparency, and response to applied voltage.

  7. Selection of Reference Genes for Expression Studies of Xenobiotic Adaptation in Tetranychus urticae.

    PubMed

    Morales, Mariany Ashanty; Mendoza, Bianca Marie; Lavine, Laura Corley; Lavine, Mark Daniel; Walsh, Douglas Bruce; Zhu, Fang

    2016-01-01

    Quantitative real-time PCR (qRT-PCR) is an extensively used, high-throughput method to analyze transcriptional expression of genes of interest. An appropriate normalization strategy with reliable reference genes is required for calculating gene expression across diverse experimental conditions. In this study, we aim to identify the most stable reference genes for expression studies of xenobiotic adaptation in Tetranychus urticae, an extremely polyphagous herbivore causing significant yield reduction of agriculture. We chose eight commonly used housekeeping genes as candidates. The qRT-PCR expression data for these genes were evaluated from seven populations: a susceptible and three acaricide resistant populations feeding on lima beans, and three other susceptible populations which had been shifted host from lima beans to three other plant species. The stability of the candidate reference genes was then assessed using four different algorithms (comparative ΔCt method, geNorm, NormFinder, and BestKeeper). Additionally, we used an online web-based tool (RefFinder) to assign an overall final rank for each candidate gene. Our study found that CycA and Rp49 are best for investigating gene expression in acaricide susceptible and resistant populations. GAPDH, Rp49, and Rpl18 are best for host plant shift studies. And GAPDH and Rp49 were the most stable reference genes when investigating gene expression under changes in both experimental conditions. These results will facilitate research in revealing molecular mechanisms underlying the xenobiotic adaptation of this notorious agricultural pest.

  8. Selection of Reference Genes for Expression Studies of Xenobiotic Adaptation in Tetranychus urticae

    PubMed Central

    Morales, Mariany Ashanty; Mendoza, Bianca Marie; Lavine, Laura Corley; Lavine, Mark Daniel; Walsh, Douglas Bruce; Zhu, Fang

    2016-01-01

    Quantitative real-time PCR (qRT-PCR) is an extensively used, high-throughput method to analyze transcriptional expression of genes of interest. An appropriate normalization strategy with reliable reference genes is required for calculating gene expression across diverse experimental conditions. In this study, we aim to identify the most stable reference genes for expression studies of xenobiotic adaptation in Tetranychus urticae, an extremely polyphagous herbivore causing significant yield reduction of agriculture. We chose eight commonly used housekeeping genes as candidates. The qRT-PCR expression data for these genes were evaluated from seven populations: a susceptible and three acaricide resistant populations feeding on lima beans, and three other susceptible populations which had been shifted host from lima beans to three other plant species. The stability of the candidate reference genes was then assessed using four different algorithms (comparative ΔCt method, geNorm, NormFinder, and BestKeeper). Additionally, we used an online web-based tool (RefFinder) to assign an overall final rank for each candidate gene. Our study found that CycA and Rp49 are best for investigating gene expression in acaricide susceptible and resistant populations. GAPDH, Rp49, and Rpl18 are best for host plant shift studies. And GAPDH and Rp49 were the most stable reference genes when investigating gene expression under changes in both experimental conditions. These results will facilitate research in revealing molecular mechanisms underlying the xenobiotic adaptation of this notorious agricultural pest. PMID:27570487

  9. A comparison of viscous-plastic sea ice solvers with and without replacement pressure

    NASA Astrophysics Data System (ADS)

    Kimmritz, Madlen; Losch, Martin; Danilov, Sergey

    2017-07-01

    Recent developments of the explicit elastic-viscous-plastic (EVP) solvers call for a new comparison with implicit solvers for the equations of viscous-plastic sea ice dynamics. In Arctic sea ice simulations, the modified and the adaptive EVP solvers, and the implicit Jacobian-free Newton-Krylov (JFNK) solver are compared against each other. The adaptive EVP method shows convergence rates that are generally similar or even better than those of the modified EVP method, but the convergence of the EVP methods is found to depend dramatically on the use of the replacement pressure (RP). Apparently, using the RP can affect the pseudo-elastic waves in the EVP methods by introducing extra non-physical oscillations so that, in the extreme case, convergence to the VP solution can be lost altogether. The JFNK solver also suffers from higher failure rates with RP implying that with RP the momentum equations are stiffer and more difficult to solve. For practical purposes, both EVP methods can be used efficiently with an unexpectedly low number of sub-cycling steps without compromising the solutions. The differences between the RP solutions and the NoRP solutions (when the RP is not being used) can be reduced with lower thresholds of viscous regularization at the cost of increasing stiffness of the equations, and hence the computational costs of solving them.

  10. Two-dimensional RPLC-RPLC system with different pH in two dimensions for separation of alkaloids from Corydalis yanhusuo W. T. Wang.

    PubMed

    Zhang, Jing; Jin, Yu; Liu, Yanfang; Xiao, Yuansheng; Feng, Jiatao; Xue, Xingya; Zhang, Xiuli; Liang, Xinmiao

    2009-06-01

    An effective method utilizing the same RP chromatographic column with different pH in first and second LC dimensions has been developed for separation of the basic compounds from traditional Chinese medicines (TCMs). In this work, the alkaloids in Corydalis yanhusuo which is an important TCM were selected as a model to develop the method. The additives and pH values of the mobile phase were optimized in this work. To investigate the feasibility of this method, off-line mode separation was performed in the experiments. According to the UV-absorption intensity, there were eight fractions collected in acidic conditions. All the fractions were analyzed in basic conditions. The results showed that the chromatographic selectivities were significantly different in the separations performed with acidic and alkaline elution systems. Complementary separation was achieved in this work. It is demonstrated that this method would be an effective tool for alkaloids research. Based on the different pH of the mobile phase in this method, it could also be suitable to analyze compounds which were sensible to the pH of the solution.

  11. Characterization of local complex structures in a recurrence plot to improve nonlinear dynamic discriminant analysis.

    PubMed

    Ding, Hang

    2014-01-01

    Structures in recurrence plots (RPs), preserving the rich information of nonlinear invariants and trajectory characteristics, have been increasingly analyzed in dynamic discrimination studies. The conventional analysis of RPs is mainly focused on quantifying the overall diagonal and vertical line structures through a method, called recurrence quantification analysis (RQA). This study extensively explores the information in RPs by quantifying local complex RP structures. To do this, an approach was developed to analyze the combination of three major RQA variables: determinism, laminarity, and recurrence rate (DLR) in a metawindow moving over a RP. It was then evaluated in two experiments discriminating (1) ideal nonlinear dynamic series emulated from the Lorenz system with different control parameters and (2) data sets of human heart rate regulations with normal sinus rhythms (n = 18) and congestive heart failure (n = 29). Finally, the DLR was compared with seven major RQA variables in terms of discriminatory power, measured by standardized mean difference (DSMD). In the two experiments, DLR resulted in the highest discriminatory power with DSMD = 2.53 and 0.98, respectively, which were 7.41 and 2.09 times the best performance from RQA. The study also revealed that the optimal RP structures for the discriminations were neither typical diagonal structures nor vertical structures. These findings indicate that local complex RP structures contain some rich information unexploited by RQA. Therefore, future research to extensively analyze complex RP structures would potentially improve the effectiveness of the RP analysis in dynamic discrimination studies.

  12. Corrosion sensor for monitoring the service condition of chloride-contaminated cement mortar.

    PubMed

    Lu, Shuang; Ba, Heng-Jing

    2010-01-01

    A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions on concrete structures. In brief, a linear polarization resistance method combined with an embeddable reference electrode was utilized to measure the polarization resistance (Rp) using built-in sensor electrodes. Subsequently, electrochemical impedance spectroscopy in the frequency range of 1 kHz to 50 kHz was used to obtain the cement mortar resistance (Rs). The results show that the polarization resistance is related to the chloride content and Rs; ln (Rp) is linearly related to the Rs values in mortar without added chloride. The relationships observed between the Rp of the steel anodes and the resistance of the surrounding cement mortar measured by the corrosion sensor confirms that Rs can indicate the corrosion state of concrete structures.

  13. Arcuate AgRP neurons mediate orexigenic and glucoregulatory actions of ghrelin★

    PubMed Central

    Wang, Qian; Liu, Chen; Uchida, Aki; Chuang, Jen-Chieh; Walker, Angela; Liu, Tiemin; Osborne-Lawrence, Sherri; Mason, Brittany L.; Mosher, Christina; Berglund, Eric D.; Elmquist, Joel K.; Zigman, Jeffrey M.

    2013-01-01

    The hormone ghrelin stimulates eating and helps maintain blood glucose upon caloric restriction. While previous studies have demonstrated that hypothalamic arcuate AgRP neurons are targets of ghrelin, the overall relevance of ghrelin signaling within intact AgRP neurons is unclear. Here, we tested the functional significance of ghrelin action on AgRP neurons using a new, tamoxifen-inducible AgRP-CreERT2 transgenic mouse model that allows spatiotemporally-controlled re-expression of physiological levels of ghrelin receptors (GHSRs) specifically in AgRP neurons of adult GHSR-null mice that otherwise lack GHSR expression. AgRP neuron-selective GHSR re-expression partially restored the orexigenic response to administered ghrelin and fully restored the lowered blood glucose levels observed upon caloric restriction. The normalizing glucoregulatory effect of AgRP neuron-selective GHSR expression was linked to glucagon rises and hepatic gluconeogenesis induction. Thus, our data indicate that GHSR-containing AgRP neurons are not solely responsible for ghrelin's orexigenic effects but are sufficient to mediate ghrelin's effects on glycemia. PMID:24567905

  14. Arcuate AgRP neurons mediate orexigenic and glucoregulatory actions of ghrelin.

    PubMed

    Wang, Qian; Liu, Chen; Uchida, Aki; Chuang, Jen-Chieh; Walker, Angela; Liu, Tiemin; Osborne-Lawrence, Sherri; Mason, Brittany L; Mosher, Christina; Berglund, Eric D; Elmquist, Joel K; Zigman, Jeffrey M

    2014-02-01

    The hormone ghrelin stimulates eating and helps maintain blood glucose upon caloric restriction. While previous studies have demonstrated that hypothalamic arcuate AgRP neurons are targets of ghrelin, the overall relevance of ghrelin signaling within intact AgRP neurons is unclear. Here, we tested the functional significance of ghrelin action on AgRP neurons using a new, tamoxifen-inducible AgRP-CreER(T2) transgenic mouse model that allows spatiotemporally-controlled re-expression of physiological levels of ghrelin receptors (GHSRs) specifically in AgRP neurons of adult GHSR-null mice that otherwise lack GHSR expression. AgRP neuron-selective GHSR re-expression partially restored the orexigenic response to administered ghrelin and fully restored the lowered blood glucose levels observed upon caloric restriction. The normalizing glucoregulatory effect of AgRP neuron-selective GHSR expression was linked to glucagon rises and hepatic gluconeogenesis induction. Thus, our data indicate that GHSR-containing AgRP neurons are not solely responsible for ghrelin's orexigenic effects but are sufficient to mediate ghrelin's effects on glycemia.

  15. LC-UV assay method and UPLC/Q-TOF-MS characterisation of saponins from Ilex paraguariensis A. St. Hil. (mate) unripe fruits.

    PubMed

    Peixoto, Maria Paula Garofo; Kaiser, Samuel; Verza, Simone Gasparin; de Resende, Pedro Ernesto; Treter, Janine; Pavei, Cabral; Borré, Gustavo Luís; Ortega, George González

    2012-01-01

    Ilex paraguariensis A. St. Hil. (mate) is known in several South American countries because of the use of its leaves in stimulant herbal beverages. High saponin contents were reported in mate leaves and unripe fruits that possess a dissimilar composition. Two LC-UV methods previously reported for mate saponins assay focused on mate leaves and the quantification of the less polar saponin fraction in mate fruits. To develop and validate a LC-UV method to assay the total content of saponins in unripe mate fruits and characterise the chemical structure of triterpenic saponins by UPLC/Q-TOF-MS. From unripe fruits of mate a crude ethanolic extract was prepared (EX40) and the mate saponin fraction (MSF) purified by solid phase extraction. The LC-UV method was validated using ilexoside II as external standard. UPLC/Q-TOF-MS was adjusted from the LC-UV method to obtain the fragmentation patterns of the main saponins present in unripe fruits. Both LC-UV and UPLC/Q-TOF-MS methods indicate a wide range of Ilex saponins polarity. The ilexoside II and total saponin content of EX40 were 8.20% (w/w) and 47.60% (w/w), respectively. The total saponin content in unripe fruits was 7.28% (w/w). The saponins present in MSF characterised by UPLC/Q-TOF-MS are derived mainly from ursolic/oleanolic, acetyl ursolic or pomolic acid. The validated LC-UV method was shown to be linear, precise, accurate and to cover several saponins previously isolated from Ilex species and could be applied for the quality control of unripe fruit saponins. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Fabrication of channeled scaffolds with ordered array of micro-pores through microsphere leaching and indirect Rapid Prototyping technique.

    PubMed

    Tan, J Y; Chua, C K; Leong, K F

    2013-02-01

    Advanced scaffold fabrication techniques such as Rapid Prototyping (RP) are generally recognized to be advantageous over conventional fabrication methods in terms architectural control and reproducibility. Yet, most RP techniques tend to suffer from resolution limitations which result in scaffolds with uncontrollable, random-size pores and low porosity, albeit having interconnected channels which is characteristically present in most RP scaffolds. With the increasing number of studies demonstrating the profound influences of scaffold pore architecture on cell behavior and overall tissue growth, a scaffold fabrication method with sufficient architectural control becomes imperative. The present study demonstrates the use of RP fabrication techniques to create scaffolds having interconnected channels as well as controllable micro-size pores. Adopted from the concepts of porogen leaching and indirect RP techniques, the proposed fabrication method uses monodisperse microspheres to create an ordered, hexagonal closed packed (HCP) array of micro-pores that surrounds the existing channels of the RP scaffold. The pore structure of the scaffold is shaped using a single sacrificial construct which comprises the microspheres and a dissolvable RP mold that were sintered together. As such, the size of pores as well as the channel configuration of the scaffold can be tailored based on the design of the RP mold and the size of microspheres used. The fabrication method developed in this work can be a promising alternative way of preparing scaffolds with customized pore structures that may be required for specific studies concerning cell-scaffold interactions.

  17. Influence of storage conditions on the stability of monomeric anthocyanins studied by reversed-phase high-performance liquid chromatography.

    PubMed

    Morais, Helena; Ramos, Cristina; Forgács, Esther; Cserháti, Tibor; Oliviera, José

    2002-04-25

    The effect of light, storage time and temperature on the decomposition rate of monomeric anthocyanin pigments extracted from skins of grape (Vitis vinifera var. Red globe) was determined by reversed-phase high-performance liquid chromatography (RP-HPLC). The impact of various storage conditions on the pigment stability was assessed by stepwise regression analysis. RP-HPLC separated well the five anthocyanins identified and proved the presence of other unidentified pigments at lower concentrations. Stepwise regression analysis confirmed that the overall decomposition rate of monomeric anthocyanins, peonidin-3-glucoside and malvidin-3-glucoside significantly depended on the time and temperature of storage, the effect of storage time being the most important. The presence or absence of light exerted a negligible impact on the decomposition rate.

  18. An Optimized Method for the Measurement of Acetaldehyde by High-Performance Liquid Chromatography

    PubMed Central

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2011-01-01

    Background Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase, and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). Methods We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent,, time and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DPN) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison to AcH-DPN standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Results Derivatization of acetaldehyde was performed at pH 4.0 with a 80-fold molar excess of DNPH. The reaction was completed in 40 min at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-min chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media, and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. Conclusions An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small volume sampling of culture media and biological fluids. PMID:21895715

  19. Evidence of Liquid Crystal-Assisted Abiotic Ligation of Nucleic Acids

    NASA Astrophysics Data System (ADS)

    Fraccia, Tommaso P.; Zanchetta, Giuliano; Rimoldi, Valeria; Clark, Noel A.; Bellini, Tommaso

    2015-06-01

    The emergence of early life must have been marked by the appearance in the prebiotic era of complex molecular structures and systems, motivating the investigation of conditions that could not only facilitate appropriate chemical synthesis, but also provide the mechanisms of molecular selection and structural templating necessary to pilot the complexification toward specific molecular patterns. We recently proposed and demonstrated that these functions could be afforded by the spontaneous ordering of ultrashort nucleic acids oligomers into Liquid Crystal (LC) phases. In such supramolecular assemblies, duplex-forming oligomers are held in average end-to-end contact to form chemically discontinuous but physically continuous double helices. Using blunt ended duplexes, we found that LC formation could both provide molecular selection mechanisms and boost inter-oligomer ligation. This paper provides an essential extension to this notion by investigating the catalytic effects of LC ordering in duplexes with mutually interacting overhangs. Specifically, we studied the influence of LC ordering of 5'-hydroxy-3'-phosphate partially self-complementary DNA 14mers with 3'-CG sticky-ends, on the efficiency of non-enzymatic ligation reaction induced by water-soluble carbodiimide EDC as condensing agent. We investigated the ligation products in mixtures of DNA with poly-ethylene glycol (PEG) at three PEG concentrations at which the system phase separates creating DNA-rich droplets that organize into isotropic, nematic LC and columnar LC phases. We observe remarkable LC-enhanced chain lengthening, and we demonstrate that such lengthening effectively promotes and stabilizes LC domains, providing the kernel of a positive feedback cycle by which LC ordering promotes elongation, in turn stabilizing the LC ordering.

  20. [Influence of liquid ceramic additive on binding of heavy metal during the vitrification of fly ash from municipal solid waste incinerator].

    PubMed

    Li, Run-dong; Nie, Yong-feng; Li, Ai-min; Wang, Lei; Chi, Yong; Cen, Ke-fa

    2004-09-01

    Vitrification process can effectively control the leachability of heavy metals in fly ash generated from municipal solid waste incinerator (MWSI). The use of liquid ceramic (LC) additive as a heavy metal chemical stabilization agent was evaluated for MSWI fly ash. The residuals of chromium, lead and zinc in slag increase by different degree with liquid ceramic additive at 1400 degrees C, while those of cadmium and copper decreases. The migrating characteristic of nickel is hardly affected by the additive less than 10%. The volatilization of Cr and Zn occurs after 61 minute with 10% addition of LC, and the binding efficiency of Cr decreases with increasing of melting temperature. The results indicate that the binding efficiency of heavy metals was affected greatly by LC additive and showed significant differences according to type of heavy metal during melting process. The short melting time (no longer than 33 min) is useful to obtain high binding efficiency of heavy metals.

  1. High-Throughput Quantification of GFP-LC3+ Dots by Automated Fluorescence Microscopy.

    PubMed

    Bravo-San Pedro, J M; Pietrocola, F; Sica, V; Izzo, V; Sauvat, A; Kepp, O; Maiuri, M C; Kroemer, G; Galluzzi, L

    2017-01-01

    Macroautophagy is a specific variant of autophagy that involves a dedicated double-membraned organelle commonly known as autophagosome. Various methods have been developed to quantify the size of the autophagosomal compartment, which is an indirect indicator of macroautophagic responses, based on the peculiar ability of microtubule-associated protein 1 light chain 3 beta (MAP1LC3B; best known as LC3) to accumulate in forming autophagosomes upon maturation. One particularly convenient method to monitor the accumulation of mature LC3 within autophagosomes relies on a green fluorescent protein (GFP)-tagged variant of this protein and fluorescence microscopy. In physiological conditions, cells transfected temporarily or stably with a GFP-LC3-encoding construct exhibit a diffuse green fluorescence over the cytoplasm and nucleus. Conversely, in response to macroautophagy-promoting stimuli, the GFP-LC3 signal becomes punctate and often (but not always) predominantly cytoplasmic. The accumulation of GFP-LC3 in cytoplasmic dots, however, also ensues the blockage of any of the steps that ensure the degradation of mature autophagosomes, calling for the implementation of strategies that accurately discriminate between an increase in autophagic flux and an arrest in autophagic degradation. Various cell lines have been engineered to stably express GFP-LC3, which-combined with the appropriate controls of flux, high-throughput imaging stations, and automated image analysis-offer a relatively straightforward tool to screen large chemical or biological libraries for inducers or inhibitors of autophagy. Here, we describe a simple and robust method for the high-throughput quantification of GFP-LC3 + dots by automated fluorescence microscopy. © 2017 Elsevier Inc. All rights reserved.

  2. Method transfer from high-pressure liquid chromatography to ultra-high-pressure liquid chromatography. I. A thermodynamic perspective.

    PubMed

    Åsberg, Dennis; Leśko, Marek; Samuelsson, Jörgen; Kaczmarski, Krzysztof; Fornstedt, Torgny

    2014-10-03

    This is the first investigation in a series that aims to enhance the scientific knowledge needed for reliable analytical method transfer between HPLC and UHPLC using the quality by design (QbD) framework. Here, we investigated the differences and similarities from a thermodynamic point of view between RP-LC separations conducted with 3.5μm (HPLC) and 1.7μm (UHPLC) C18 particles. Three different model solutes and one pharmaceutical compound were used: the uncharged cycloheptanone, the cationic benzyltriethylammonium chloride, the anionic sodium 2-naphatlene sulfonate and the pharmaceutical compound omeprazole, which was anionic at the studied pH. Adsorption data were determined for the four solutes at varying fractions of organic modifier and in gradient elution in both the HPLC and UHPLC system, respectively. From the adsorption data, the adsorption energy distribution of each compound was calculated and the adsorption isotherm model was estimated. We found that the adsorption energy distribution was similar, with only minor differences in degree of homogeneity, for HPLC and UHPLC stationary phases. The adsorption isotherm model did not change between HPLC and UHPLC, but the parameter values changed considerably especially for the ionic compounds. The dependence of the organic modifier followed the same trend in HPLC as in UHPLC. These results indicates that the adsorption mechanism of a solute is the same on HPLC and UHPLC stationary phases which simplifies design of a single analytical method applicable to both HPLC and UHPLC conditions within the QbD framework. Copyright © 2014. Published by Elsevier B.V.

  3. Screening of 23 β-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction.

    PubMed

    Bessaire, Thomas; Mujahid, Claudia; Beck, Andrea; Tarres, Adrienne; Savoy, Marie-Claude; Woo, Pei-Mun; Mottier, Pascal; Desmarchelier, Aurélien

    2018-04-01

    A fast and robust high performance LC-MS/MS screening method was developed for the analysis of β-lactam antibiotics in foods of animal origin: eggs, raw milk, processed dairy ingredients, infant formula, and meat- and fish-based products including baby foods. QuEChERS extraction with some adaptations enabled 23 drugs to be simultaneously monitored. Screening target concentrations were set at levels adequate to ensure compliance with current European, Chinese, US and Canadian regulations. The method was fully validated according to the European Community Reference Laboratories Residues Guidelines using 93 food samples of different composition. False-negative and false-positive rates were below 5% for all analytes. The method is adequate for use in high-routine laboratories. A 1-year study was additionally conducted to assess the stability of the 23 analytes in the working standard solution.

  4. Role of neutrophils in radical production during ischemia and reperfusion of the rat brain: effect of neutrophil depletion on extracellular ascorbyl radical formation.

    PubMed

    Matsuo, Y; Kihara, T; Ikeda, M; Ninomiya, M; Onodera, H; Kogure, K

    1995-11-01

    A growing body of experimental data indicate that oxygen radicals may mediate the brain injury during ischemia-reperfusion. One potential source of oxygen radicals is activated neutrophils. To study the role of neutrophils in radical production during cerebral ischemia-reperfusion, we evaluated the effects of depletion of circulating neutrophils by administration of an anti-neutrophil monoclonal antibody (RP3) on radical formation in rats with 1-h middle cerebral artery (MCA) occlusion. In the present study, we employed a new electron spin resonance method coupled with brain microdialysis. The method uses the endogenous ascorbyl radical (AR) concentration as a marker of oxygen radicals and requires no spin-trapping agents. In the vehicle controls, extracellular AR decreased during MCA occlusion. After reperfusion, AR significantly increased at 30 min and 1 h, returned to near basal level until 2 h, and increased again at 24 h after reperfusion. In the rats treated with RP3, AR decreased during MCA occlusion to the same extent as in the vehicle control. However, RP3 treatment completely inhibited the increase in extracellular AR after reperfusion. RP3 treatment exerted no effect on the changes in extracellular ascorbate or tissue PO2 throughout the experimental period. In conclusion, neutrophils are a major source of oxygen radicals during reperfusion after focal cerebral ischemia.

  5. Controlling Oxygen Mobility in Ruddlesden–Popper Oxides

    PubMed Central

    Lee, Dongkyu; Lee, Ho Nyung

    2017-01-01

    Discovering new energy materials is a key step toward satisfying the needs for next-generation energy conversion and storage devices. Among the various types of oxides, Ruddlesden–Popper (RP) oxides (A2BO4) are promising candidates for electrochemical energy devices, such as solid oxide fuel cells, owing to their attractive physicochemical properties, including the anisotropic nature of oxygen migration and controllable stoichiometry from oxygen excess to oxygen deficiency. Thus, understanding and controlling the kinetics of oxygen transport are essential for designing optimized materials to use in electrochemical energy devices. In this review, we first discuss the basic mechanisms of oxygen migration in RP oxides depending on oxygen nonstoichiometry. We then focus on the effect of changes in the defect concentration, crystallographic orientation, and strain on the oxygen migration in RP oxides. We also briefly review their thermal and chemical stability. Finally, we conclude with a perspective on potential research directions for future investigation to facilitate controlling oxygen ion migration in RP oxides. PMID:28772732

  6. An assessment of the feasibility and effectiveness of an e-learning module in delivering a curriculum in radiation protection to undergraduate medical students.

    PubMed

    Leong, Sum; Mc Laughlin, Patrick; O'Connor, Owen J; O'Flynn, Siun; Maher, Michael M

    2012-03-01

    Integrating radiation protection (RP) education in the undergraduate medical curriculum is gaining importance and is mandatory in certain jurisdictions. An e-learning module for RP was developed at the authors' medical school and was integrated into year 4 of the 5-year undergraduate medical program. The aim of this study was to investigate its impact on RP knowledge, student preferences for various teaching methods, self-assessment of RP knowledge, and perceptions of career prospects in radiology. Likert-type 5-point scale evaluations and general comments about the RP module and various methods of teaching were also obtained. An e-learning module in RP was designed and presented to year 4 medical undergraduates. All students were required to complete premodule and postmodule questionnaires. Eighty-nine percent (n = 113) and 99% (n = 126) of the 127 medical students successfully completed and returned the premodule and postmodule questionnaires, respectively. After the e-learning module, students' postmodule RP knowledge had improved significantly. Analysis of postmodule RP knowledge suggested that a favorable self-assessment of knowledge of RP, perception of career prospects in radiology, and completion of the e-learning module with an increased number of sessions were factors predictive of improved RP knowledge. Students expressed a preference for didactic lectures and clinical attachment for instruction in RP over e-learning. The development of an e-learning module in RP is feasible and results in improved knowledge of RP among medical undergraduates. Combining e-learning and more traditional educational programs such as a clinical radiology rotation is likely to improve student experience. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Synthesis of structured lipid enriched with omega fatty acids and sn-2 palmitic acid by enzymatic esterification and its incorporation in powdered infant formula.

    PubMed

    Nagachinta, Supakana; Akoh, Casimir C

    2013-05-08

    Structured lipid (SL) enriched with arachidonic (ARA) and docosahexaenoic (DHA) acids was produced from tripalmitin using Lipozyme TL IM. The effects of acyl donors, that is, free fatty acids vs fatty acid ethyl esters, on the reactions were compared. The highest total incorporation of ARA and DHA was obtained when the reaction continued for 24 h, at a substrate mole ratio of 9, using free fatty acids as acyl donors (acidolysis). The SL prepared by a large-scale acidolysis reaction contained 17.69 ± 0.09% total ARA, 10.75 ± 0.15% total DHA, and 48.53 ± 1.40% sn-2 palmitic acid. SL thermograms exhibited multiple peaks indicating complexity of the triacylglycerol (TAG) distribution. RP-HPLC analysis of SL revealed nine of 26 TAG molecular species that were similar to those of human milk fat. Powdered infant formulas containing the SL were prepared by wet-mixing/spray-drying and dry-blending methods. Formula prepared with microencapsulated SL and the dry-blending method had better oxidative stability and color quality.

  8. Selective ribosome profiling as a tool to study the interaction of chaperones and targeting factors with nascent polypeptide chains and ribosomes

    PubMed Central

    Becker, Annemarie H.; Oh, Eugene; Weissman, Jonathan S.; Kramer, Günter; Bukau, Bernd

    2014-01-01

    A plethora of factors is involved in the maturation of newly synthesized proteins, including chaperones, membrane targeting factors, and enzymes. Many factors act cotranslationally through association with ribosome-nascent chain complexes (RNCs), but their target specificities and modes of action remain poorly understood. We developed selective ribosome profiling (SeRP) to identify substrate pools and points of RNC engagement of these factors. SeRP is based on sequencing mRNA fragments covered by translating ribosomes (general ribosome profiling, RP), combined with a procedure to selectively isolate RNCs whose nascent polypeptides are associated with the factor of interest. Factor–RNC interactions are stabilized by crosslinking, the resulting factor–RNC adducts are then nuclease-treated to generate monosomes, and affinity-purified. The ribosome-extracted mRNA footprints are converted to DNA libraries for deep sequencing. The protocol is specified for general RP and SeRP in bacteria. It was first applied to the chaperone trigger factor and is readily adaptable to other cotranslationally acting factors, including eukaryotic factors. Factor–RNC purification and sequencing library preparation takes 7–8 days, sequencing and data analysis can be completed in 5–6 days. PMID:24136347

  9. The Structural Basis for Lipid and Endotoxin Binding in RP105-MD-1, and Consequences for Regulation of Host Lipopolysaccharide Sensitivity.

    PubMed

    Ortiz-Suarez, Maite L; Bond, Peter J

    2016-01-05

    MD-1 is a member of the MD-2-related lipid-recognition (ML) family, and associates with RP105, a cell-surface protein that resembles Toll-like receptor 4 (TLR4). The RP105⋅MD-1 complex has been proposed to play a role in fine-tuning the innate immune response to endotoxin such as bacterial lipopolysaccharide (LPS) via TLR4⋅MD-2, but controversy surrounds its mechanism. We have used atomically detailed simulations to reveal the structural basis for ligand binding and consequent functional dynamics of MD-1 and the RP105 complex. We rationalize reports of endogenous phospholipid binding, by showing that they prevent collapse of the malleable MD-1 fold, before refining crystallographic models and uncovering likely binding modes for LPS analogs. Subsequent binding affinity calculations reveal that endotoxin specificity arises from the entropic cost of expanding the MD-1 cavity to accommodate bulky lipid tails, and support the role of MD-1 as a "sink" that sequesters endotoxin from TLR4 and stabilizes RP105/TLR4 interactions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.

    PubMed

    Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans

    2018-06-01

    In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.

  11. Stability of CIGS Solar Cells and Component Materials Evaluated by a Step-Stress Accelerated Degradation Test Method: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pern, F. J.; Noufi, R.

    A step-stress accelerated degradation testing (SSADT) method was employed for the first time to evaluate the stability of CuInGaSe2 (CIGS) solar cells and device component materials in four Al-framed test structures encapsulated with an edge sealant and three kinds of backsheet or moisture barrier film for moisture ingress control. The SSADT exposure used a 15oC and then a 15% relative humidity (RH) increment step, beginning from 40oC/40%RH (T/RH = 40/40) to 85oC/70%RH (85/70) as of the moment. The voluminous data acquired and processed as of total DH = 3956 h with 85/70 = 704 h produced the following results. Themore » best CIGS solar cells in sample Set-1 with a moisture-permeable TPT backsheet showed essentially identical I-V degradation trend regardless of the Al-doped ZnO (AZO) layer thickness ranging from standard 0.12 μm to 0.50 μm on the cells. No clear 'stepwise' feature in the I-V parameter degradation curves corresponding to the SSADT T/RH/time profile was observed. Irregularity in I-V performance degradation pattern was observed with some cells showing early degradation at low T/RH < 55/55 and some showing large Voc, FF, and efficiency degradation due to increased series Rs (ohm-cm2) at T/RH ≥ 70/70. Results of (electrochemical) impedance spectroscopy (ECIS) analysis indicate degradation of the CIGS solar cells corresponded to increased series resistance Rs (ohm) and degraded parallel (minority carrier diffusion/recombination) resistance Rp, capacitance C, overall time constant Rp*C, and 'capacitor quality' factor (CPE-P), which were related to the cells? p-n junction properties. Heating at 85/70 appeared to benefit the CIGS solar cells as indicated by the largely recovered CPE-P factor. Device component materials, Mo on soda lime glass (Mo/SLG), bilayer ZnO (BZO), AlNi grid contact, and CdS/CIGS/Mo/SLG in test structures with TPT showed notable to significant degradation at T/RH ≥ 70/70. At T/RH = 85/70, substantial blistering of BZO layers on CIGS cell pieces was observed that was not seen on BZO/glass, and a CdS/CIGS sample displayed a small darkening and then flaking feature. Additionally, standard AlNi grid contact was less stable than thin Ni grid contact at T/RH ≥ 70/70. The edge sealant and moisture-blocking films were effective to block moisture ingress, as evidenced by the good stability of most CIGS solar cells and device components at T/RH = 85/70 for 704 h, and by preservation of the initial blue color on the RH indicator strips. The SSADT experiment is ongoing to be completed at T/RH = 85/85.« less

  12. Therapeutic Approaches for Botulinum Intoxication Targeting Degradation of the Light Chain

    DTIC Science & Technology

    2014-06-01

    protein and producing adequate amounts for in vitro testing. 15. SUBJECT TERMS- Botulinum toxin , ubiquitin, chimeric toxin light chains, LcA, LcE...that confer stability to LCs of botulinum toxin can be assessed by mutation of dileucine residues and systematic deletion of residues from LcA-LcE...cells. So What? Currently, there is no cure for botulinum poisoning once the toxin has entered a neuron. Moreover, the half-life of BoNT/A is very

  13. [Experimental study of infrasonic phonophoresis].

    PubMed

    Filatov, V V

    2001-01-01

    A new method of drug administration, infrared phonophoresis, was experimentally studied. The method has no analogs in the world. The study was carried out on 20 Chinchilla rabbits. Water applications impregnated with equal volumes of the radiopharmaceutical (RP) were placed into the conjunctival cavities of both eyes. The right eye was control and the left was treated by infrasound (experiment). The information was recorded in live animals after removal of the application and thorough washing of the conjunctival cavity immediately, 30 min, and 1 h after infrasound phonophoresis session. Radioactivity measurements at all terms indicate its stable increase in the experimental eye and a progressive decrease in the control eye. Hence, infrasound promoted long accumulation of the RP in the eye at anterior route of the drug delivery without preliminary injection of the drug into ocular vessels.

  14. Interactions of amelogenin with phospholipids

    DOE PAGES

    Bekshe Lokappa, Sowmya; Chandrababu, Karthik Balakrishna; Dutta, Kaushik; ...

    2014-11-22

    Amelogenin protein has the potential to interact with other enamel matrix proteins, mineral, and cell surfaces. In this paper, we investigated the interactions of recombinant amelogenin rP172 with small unilamellar vesicles as model membranes, toward the goal of understanding the mechanisms of amelogenin–cell interactions during amelogenesis. Dynamic light scattering (DLS), fluorescence spectroscopy, circular dichroism (CD), and nuclear magnetic resonance (NMR) were used. In the presence of phospholipid vesicles, a blue shift in the Trp fluorescence emission maxima of rP172 was observed (~334 nm) and the Trp residues of rP172 were inaccessible to the aqueous quencher acrylamide. DLS studies indicated complexationmore » of rP172 and phospholipids, although the possibility of fusion of phospholipids following amelogenin addition cannot be ruled out. NMR and CD studies revealed a disorder–order transition of rP172 in a model membrane environment. Strong fluorescence resonance energy transfer from Trp in rP172 to DNS-bound-phospholipid was observed, and fluorescence polarization studies indicated that rP172 interacted with the hydrophobic core region of model membranes. Finally, our data suggest that amelogenin has ability to interact with phospholipids and that such interactions may play key roles in enamel biomineralization as well as reported amelogenin signaling activities.« less

  15. Validation of RP-HPLC method and stress degradation for the combination of metformin HCl, atorvastatin calcium and glimepiride: application to nanoparticles.

    PubMed

    Gite, Sandip; Patravale, Vandana

    2015-01-01

    A stability-indicating high-performance liquid chromatography (HPLC) procedure was developed for the determination of metformin HCl (MTH), atorvastatin calcium (AC) and glimepiride (GP) in combination and their main degradation products. The separation and quantization were achieved on a 5-µm Qualisil gold, C18 column (4.6 mm × 250 mm). The mobile phase selected was phosphate buffer (pH 2.9)-organic phase in proportion of 70:30. Organic phase consisted of methanol-acetonitrile (90:10) at a flow rate of 1 mL/min and detection of analytes was carried out at 230 nm. The method exhibited good linearity over the range of 10-60 µg/mL for MTH, 2-20 µg/mL for AC and 5-30 µg/mL for GP. Square of the correlation coefficients was found to be >0.999. Various stress degradation studies were carried out in combination as per International Conference of Harmonization (ICH) guidelines for 4 h. The recovery and precision were determined in terms of intraday and interday precisions and expressed as relative standard deviations. These were <1 and <2%, respectively. Finally, the applicability of the method was evaluated in nanoparticle analysis of MTH, AC and GP as well as in stability studies of nanoformulation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. The prognostic value of interleukin-17 in lung cancer: A systematic review with meta-analysis based on Chinese patients.

    PubMed

    Wang, Xiao-Fei; Zhu, Yi-Tong; Wang, Jia-Jia; Zeng, Da-Xiong; Mu, Chuan-Yong; Chen, Yan-Bin; Lei, Wei; Zhu, Ye-Han; Huang, Jian-An

    2017-01-01

    Interleukin-17 (IL-17) plays an important role in cancer progression. Previous studies remained controversial regarding the correlation between IL-17 expression and lung cancer (LC) prognosis. To comprehensively and quantitatively summarize the prognostic value of IL-17 expression in LC patients, a systematic review and meta-analysis were performed. We identified the relevant literatures by searching the PubMed, EMBASE, Cochrane Library, SinoMed, China National Knowledge Infrastructure (CNKI) and Wanfang Data databases, up until April 1, 2017. Overall survival (OS), disease free survival (DFS) and clinicopathological characteristics were collected from relevant studies. Pooled hazard ratios (HR) and corresponding 95% confidence intervals (CI) were calculated to estimate the effective value of IL-17 expression on clinical outcomes. Six studies containing 479 Chinese LC patients were involved in this meta-analysis. The results indicated high IL-17 expression was independently correlated with poorer OS (HR = 1.82, 95% CI 1.44-2.29, P < 0.00001) and shorter DFS (HR = 2.41, 95% CI 1.42-4.08, P = 0.001) in LC patients. Further, when stratified by LC histological type (non-small cell lung cancer and small cell lung cancer), tumor stage (Ⅰ-Ⅲ,Ⅰ-Ⅳ and Ⅳ), detection specimen (serum, intratumoral tissue and pleural effusion), test method (immunological histological chemistry and enzyme linked immunosorbent assay), and HR estimated method (reported and estimated), all of the results were statistically significant. These data indicated that elevated IL-17 expression is correlated with poor clinical outcomes in LC. The meta-analysis did not show heterogeneity or publication bias. The present meta-analysis revealed that high IL-17 expression was an indicator of poor prognosis for Chinese patients with LC. It could potentially help to assess patients' prognosis and estimate treatment efficacy in therapeutic interventions.

  17. An optimized method for the measurement of acetaldehyde by high-performance liquid chromatography.

    PubMed

    Guan, Xiangying; Rubin, Emanuel; Anni, Helen

    2012-03-01

    Acetaldehyde is produced during ethanol metabolism predominantly in the liver by alcohol dehydrogenase and rapidly eliminated by oxidation to acetate via aldehyde dehydrogenase. Assessment of circulating acetaldehyde levels in biological matrices is performed by headspace gas chromatography and reverse phase high-performance liquid chromatography (RP-HPLC). We have developed an optimized method for the measurement of acetaldehyde by RP-HPLC in hepatoma cell culture medium, blood, and plasma. After sample deproteinization, acetaldehyde was derivatized with 2,4-dinitrophenylhydrazine (DNPH). The reaction was optimized for pH, amount of derivatization reagent, time, and temperature. Extraction methods of the acetaldehyde-hydrazone (AcH-DNP) stable derivative and product stability studies were carried out. Acetaldehyde was identified by its retention time in comparison with AcH-DNP standard, using a new chromatography gradient program, and quantitated based on external reference standards and standard addition calibration curves in the presence and absence of ethanol. Derivatization of acetaldehyde was performed at pH 4.0 with an 80-fold molar excess of DNPH. The reaction was completed in 40 minutes at ambient temperature, and the product was stable for 2 days. A clear separation of AcH-DNP from DNPH was obtained with a new 11-minute chromatography program. Acetaldehyde detection was linear up to 80 μM. The recovery of acetaldehyde was >88% in culture media and >78% in plasma. We quantitatively determined the ethanol-derived acetaldehyde in hepatoma cells, rat blood and plasma with a detection limit around 3 μM. The accuracy of the method was <9% for intraday and <15% for interday measurements, in small volume (70 μl) plasma sampling. An optimized method for the quantitative determination of acetaldehyde in biological systems was developed using derivatization with DNPH, followed by a short RP-HPLC separation of AcH-DNP. The method has an extended linear range, is reproducible and applicable to small-volume sampling of culture media and biological fluids. Copyright © 2011 by the Research Society on Alcoholism.

  18. Effects of the pH and Concentration on the Stability of Standard Solutions of Proteinogenic Amino Acid Mixtures.

    PubMed

    Kato, Megumi; Yamazaki, Taichi; Kato, Hisashi; Yamanaka, Noriko; Takatsu, Akiko; Ihara, Toshihide

    2017-01-01

    To prepare metrologically traceable amino acid mixed standard solutions, it is necessary to determine the stability of each amino acid present in the mixed solutions. In the present study, we prepared amino acid mixed solutions using certified reference standards of 17 proteinogenic amino acids, and examined the stability of each of these amino acids in 0.1 N HCl. We found that the concentration of glutamic acid decreased significantly during storage. LC/MS analysis indicated that the instability of glutamic acid was due to the partial degradation of glutamic acid to pyroglutamic acid in 0.1 N HCl. Using accelerated degradation tests, we investigated several solvent compositions to improve the stability of glutamic acid in amino acid mixed solution, and determined that the change of the pH by diluting the mixed solution improved the stability of glutamic acid.

  19. Modeling RP-1 fuel advanced distillation data using comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry and partial least squares analysis.

    PubMed

    Kehimkar, Benjamin; Parsons, Brendon A; Hoggard, Jamin C; Billingsley, Matthew C; Bruno, Thomas J; Synovec, Robert E

    2015-01-01

    Recent efforts in predicting rocket propulsion (RP-1) fuel performance through modeling put greater emphasis on obtaining detailed and accurate fuel properties, as well as elucidating the relationships between fuel compositions and their properties. Herein, we study multidimensional chromatographic data obtained by comprehensive two-dimensional gas chromatography combined with time-of-flight mass spectrometry (GC × GC-TOFMS) to analyze RP-1 fuels. For GC × GC separations, RTX-Wax (polar stationary phase) and RTX-1 (non-polar stationary phase) columns were implemented for the primary and secondary dimensions, respectively, to separate the chemical compound classes (alkanes, cycloalkanes, aromatics, etc.), providing a significant level of chemical compositional information. The GC × GC-TOFMS data were analyzed using partial least squares regression (PLS) chemometric analysis to model and predict advanced distillation curve (ADC) data for ten RP-1 fuels that were previously analyzed using the ADC method. The PLS modeling provides insight into the chemical species that impact the ADC data. The PLS modeling correlates compositional information found in the GC × GC-TOFMS chromatograms of each RP-1 fuel, and their respective ADC, and allows prediction of the ADC for each RP-1 fuel with good precision and accuracy. The root-mean-square error of calibration (RMSEC) ranged from 0.1 to 0.5 °C, and was typically below ∼0.2 °C, for the PLS calibration of the ADC modeling with GC × GC-TOFMS data, indicating a good fit of the model to the calibration data. Likewise, the predictive power of the overall method via PLS modeling was assessed using leave-one-out cross-validation (LOOCV) yielding root-mean-square error of cross-validation (RMSECV) ranging from 1.4 to 2.6 °C, and was typically below ∼2.0 °C, at each % distilled measurement point during the ADC analysis.

  20. Characterization of macular structure and function in two Swedish families with genetically identified autosomal dominant retinitis pigmentosa

    PubMed Central

    Abdulridha-Aboud, Wissam; Kjellström, Ulrika; Andréasson, Sten

    2016-01-01

    Purpose To study the phenotype in two families with genetically identified autosomal dominant retinitis pigmentosa (adRP) focusing on macular structure and function. Methods Clinical data were collected at the Department of Ophthalmology, Lund University, Sweden, for affected and unaffected family members from two pedigrees with adRP. Examinations included optical coherence tomography (OCT), full-field electroretinography (ffERG), and multifocal electroretinography (mfERG). Molecular genetic screening was performed for known mutations associated with adRP. Results The mode of inheritance was autosomal dominant in both families. The members of the family with a mutation in the PRPF31 (p.IVS6+1G>T) gene had clinical features characteristic of RP, with severely reduced retinal rod and cone function. The degree of deterioration correlated well with increasing age. The mfERG showed only centrally preserved macular function that correlated well with retinal thinning on OCT. The family with a mutation in the RHO (p.R135W) gene had an extreme intrafamilial variability of the phenotype, with more severe disease in the younger generations. OCT showed pathology, but the degree of morphological changes was not correlated with age or with the mfERG results. The mother, with a de novo mutation in the RHO (p.R135W) gene, had a normal ffERG, and her retinal degeneration was detected merely with the reduced mfERG. Conclusions These two families demonstrate the extreme inter- and intrafamilial variability in the clinical phenotype of adRP. This is the first Swedish report of the clinical phenotype associated with a mutation in the PRPF31 (p.IVS6+1G>T) gene. Our results indicate that methods for assessment of the central retinal structure and function may improve the detection and characterization of the RP phenotype. PMID:27212874

  1. Stability-indicating LC assay for butenafine hydrochloride in creams using an experimental design for robustness evaluation and photodegradation kinetics study.

    PubMed

    Barth, Aline Bergesch; de Oliveira, Gabriela Bolfe; Malesuik, Marcelo Donadel; Paim, Clésio Soldatelli; Volpato, Nadia Maria

    2011-08-01

    A stability-indicating liquid chromatography method for the determination of the antifungal agent butenafine hydrochloride (BTF) in a cream was developed and validated using the Plackett-Burman experimental design for robustness evaluation. Also, the drug photodegradation kinetics was determined. The analytical column was operated with acetonitrile, methanol and a solution of triethylamine 0.3% adjusted to pH 4.0 (6:3:1) at a flow rate of 1 mL/min and detection at 283 nm. BTF extraction from the cream was done with n-butyl alcohol and methanol in ultrasonic bath. The performed degradation conditions were: acid and basic media with HCl 1M and NaOH 1M, respectively, oxidation with H(2)O(2) 10%, and the exposure to UV-C light. No interference in the BTF elution was verified. Linearity was assessed (r(2) = 0.9999) and ANOVA showed non-significative linearity deviation (p > 0.05). Adequate results were obtained for repeatability, intra-day precision, and accuracy. Critical factors were selected to examine the method robustness with the two-level Plackett-Burman experimental design and no significant factors were detected (p > 0.05). The BTF photodegradation kinetics was determined for the standard and for the cream, both in methanolic solution, under UV light at 254 nm. The degradation process can be described by first-order kinetics in both cases.

  2. Biological properties of prolactin-releasing peptide analogs with a modified aromatic ring of a C-terminal phenylalanine amide.

    PubMed

    Maletínská, Lenka; Spolcová, Andrea; Maixnerová, Jana; Blechová, Miroslava; Zelezná, Blanka

    2011-09-01

    Prolactin-releasing peptide (PrRP)-induced secretion of prolactin is not currently considered a primary function of PrRP, but the development of late-onset obesity in both PrRP and PrRP receptor knock-out mice indicates the unique anorexigenic properties of PrRP. In our recent study, we showed comparable potencies of peptides PrRP31 and PrRP20 in binding, intracellular signaling and prolactin release in pituitary RC-4B/C cells, and anorexigenic effect after central administration in fasted mice. In the present study, eight analogs of PrRP20 with C-terminal Phe amide modified with a bulky side chain or a halogenated aromatic ring revealed high binding potency, activation of mitogen-activated protein kinase/extracellular-regulated kinase (MAPK/ERK1/2) and cAMP response element-binding protein (CREB) and prolactin release in RC-4B/C cells. In particular, [PheNO(2)(31)]PrRP20, [1-Nal(31)]PrRP20, [2-Nal(31)]PrRP20 and [Tyr(31)]PrRP20 showed not only in vitro effects comparable or higher than those of PrRP20, but also a very significant and long-lasting anorexigenic effect after central administration in fasted mice. The design of potent and long-lasting PrRP analogs with selective anorexigenic properties promises to contribute to the study of food intake disorders. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Characterization of Retinitis Pigmentosa Using Fluorescence Lifetime Imaging Ophthalmoscopy (FLIO).

    PubMed

    Andersen, Karl M; Sauer, Lydia; Gensure, Rebekah H; Hammer, Martin; Bernstein, Paul S

    2018-06-01

    We investigated fundus autofluorescence (FAF) lifetimes in patients with retinitis pigmentosa (RP) using fluorescence lifetime imaging ophthalmoscopy (FLIO). A total of 33 patients (mean age, 40.0 ± 17.0 years) with RP and an age-matched healthy group were included. The Heidelberg FLIO was used to detect FAF decays in short (SSC; 498-560 nm) and long (LSC; 560-720 nm) spectral channels. We investigated a 30° retinal field and calculated the amplitude-weighted mean fluorescence lifetime (τ m ). Additionally, macular pigment measurements, macular optical coherence tomography (OCT) scans, fundus photographs, visual fields, and fluorescein angiograms were recorded. Genetic studies were performed on nearly all patients. In RP, FLIO shows a typical pattern of prolonged τ m in atrophic regions in the outer macula (SSC, 419 ± 195 ps; LSC, 401 ± 111 ps). Within the relatively preserved retina in the macular region, ring-shaped patterns were found, most distinctive in patients with autosomal dominant RP inheritance. Mean FAF lifetimes were shortened in rings in the LSC. Central areas remained relatively unaffected. FLIO uniquely presents a distinct and specific signature in eyes affected with RP. The ring patterns show variations that indicate genetically determined pathologic processes. Shortening of FAF lifetimes in the LSC may indicate disease progression, as was previously demonstrated for Stargardt disease. Therefore, FLIO might be able to indicate disease progression in RP as well. Hyperfluorescent FLIO rings with short FAF lifetimes may provide insight into the pathophysiologic disease status of RP-affected retinas potentially providing a more detailed assessment of disease progression.

  4. Biosimilars in Inflammatory Bowel Disease: Facts and Fears of Extrapolation.

    PubMed

    Ben-Horin, Shomron; Vande Casteele, Niels; Schreiber, Stefan; Lakatos, Peter Laszlo

    2016-12-01

    Biologic drugs such as infliximab and other anti-tumor necrosis factor monoclonal antibodies have transformed the treatment of immune-mediated inflammatory conditions such as Crohn's disease and ulcerative colitis (collectively known as inflammatory bowel disease [IBD]). However, the complex manufacturing processes involved in producing these drugs mean their use in clinical practice is expensive. Recent or impending expiration of patents for several biologics has led to development of biosimilar versions of these drugs, with the aim of providing substantial cost savings and increased accessibility to treatment. Biosimilars undergo an expedited regulatory process. This involves proving structural, functional, and biological biosimilarity to the reference product (RP). It is also expected that clinical equivalency/comparability will be demonstrated in a clinical trial in one (or more) sensitive population. Once these requirements are fulfilled, extrapolation of biosimilar approval to other indications for which the RP is approved is permitted without the need for further clinical trials, as long as this is scientifically justifiable. However, such justification requires that the mechanism(s) of action of the RP in question should be similar across indications and also comparable between the RP and the biosimilar in the clinically tested population(s). Likewise, the pharmacokinetics, immunogenicity, and safety of the RP should be similar across indications and comparable between the RP and biosimilar in the clinically tested population(s). To date, most anti-tumor necrosis factor biosimilars have been tested in trials recruiting patients with rheumatoid arthritis. Concerns have been raised regarding extrapolation of clinical data obtained in rheumatologic populations to IBD indications. In this review, we discuss the issues surrounding indication extrapolation, with a focus on extrapolation to IBD. Copyright © 2016 AGA Institute. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of the effect of various beverages and food material on the color stability of provisional materials – An in vitro study

    PubMed Central

    Gupta, Gaurav; Gupta, Tina

    2011-01-01

    Aim: This study evaluated the color stability of four provisional materials: 1) Poly-methyl methacrylates (DPI); 2) Bis-acryl composite (ProtempTM II – 3M ESPE); 3) Bis-acryl composite (Systemp® c and b – Ivoclar Vivadent) and 4) Light polymerized composite resin (Revotek LC- GC). Materials and Methods: The color and color difference of each specimen after immersion in different staining solutions i.e. 1) tea and artificial saliva, 2) coffee and artificial saliva, 3) Pepsi and artificial saliva, 4) turmeric solution and artificial saliva was measured using reflectance spectrophotometer with CIELAB system before immersion and after immersion at 2, 5 ,7 , 10 and 15 days. Results: Revotek LC- GC (light polymerized composite resin) was found to be the most color stable provisional restorative material followed by Protemp II (Bis-acryl composite), Systemp (Bis-acryl composite) and DPI (Methylmethacrylate resin). Turmeric solution had the maximum staining potential followed by coffee, tea and Pepsi. PMID:22025835

  6. Validation of HPLC and UV spectrophotometric methods for the determination of meropenem in pharmaceutical dosage form.

    PubMed

    Mendez, Andreas S L; Steppe, Martin; Schapoval, Elfrides E S

    2003-12-04

    A high-performance liquid chromatographic method and a UV spectrophotometric method for the quantitative determination of meropenem, a highly active carbapenem antibiotic, in powder for injection were developed in present work. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by reversed-phase technique on an RP-18 column with a mobile phase composed of 30 mM monobasic phosphate buffer and acetonitrile (90:10; v/v), adjusted to pH 3.0 with orthophosphoric acid. The UV spectrophotometric method was performed at 298 nm. The samples were prepared in water and the stability of meropenem in aqueous solution at 4 and 25 degrees C was studied. The results were satisfactory with good stability after 24 h at 4 degrees C. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and can be used for the reliable quantitation of meropenem in pharmaceutical dosage form.

  7. Absolute quantitation of disease protein biomarkers in a single LC-MS acquisition using apolipoprotein F as an example.

    PubMed

    Kumar, Abhinav; Gangadharan, Bevin; Cobbold, Jeremy; Thursz, Mark; Zitzmann, Nicole

    2017-09-21

    LC-MS and immunoassay can detect protein biomarkers. Immunoassays are more commonly used but can potentially be outperformed by LC-MS. These techniques have limitations including the necessity to generate separate calibration curves for each biomarker. We present a rapid mass spectrometry-based assay utilising a universal calibration curve. For the first time we analyse clinical samples using the HeavyPeptide IGNIS kit which establishes a 6-point calibration curve and determines the biomarker concentration in a single LC-MS acquisition. IGNIS was tested using apolipoprotein F (APO-F), a potential biomarker for non-alcoholic fatty liver disease (NAFLD). Human serum and IGNIS prime peptides were digested and the IGNIS assay was used to quantify APO-F in clinical samples. Digestion of IGNIS prime peptides was optimised using trypsin and SMART Digest™. IGNIS was 9 times faster than the conventional LC-MS method for determining the concentration of APO-F in serum. APO-F decreased across NAFLD stages. Inter/intra-day variation and stability post sample preparation for one of the peptides was ≤13% coefficient of variation (CV). SMART Digest™ enabled complete digestion in 30 minutes compared to 24 hours using in-solution trypsin digestion. We have optimised the IGNIS kit to quantify APO-F as a NAFLD biomarker in serum using a single LC-MS acquisition.

  8. The Impact of Symptom Dimensions on Outcome for Exposure and Ritual Prevention Therapy in Obsessive-Compulsive Disorder

    PubMed Central

    Williams, Monnica T.; Farris, Samantha G.; Turkheimer, Eric N.; Franklin, Martin E.; Simpson, H. Blair; Liebowitz, Michael; Foa, Edna B.

    2014-01-01

    Objective Obsessive-compulsive disorder (OCD) is a severe condition with varied symptom presentations. The behavioral treatment with the most empirical support is exposure and ritual prevention (EX/RP). This study examined the impact of symptom dimensions on EX/RP outcomes in OCD patients. Method The Yale-Brown Obsessive-Compulsive Scale (Y-BOCS) was used to determine primary symptoms for each participant. An exploratory factor analysis (EFA) of 238 patients identified five dimensions: contamination/cleaning, doubts about harm/checking, hoarding, symmetry/ordering, and unacceptable/taboo thoughts (including religious/moral and somatic obsessions among others). A linear regression was conducted on those who had received EX/RP (n = 87) to examine whether scores on the five symptom dimensions predicted post-treatment Y-BOCS scores, accounting for pre-treatment Y-BOCS scores. Results The average reduction in Y-BOCS score was 43.0%, however the regression indicated that unacceptable/taboo thoughts (β = .27, p = .02) and hoarding dimensions (β = .23, p = .04) were associated with significantly poorer EX/RP treatment outcomes. Specifically, patients endorsing religious/moral obsessions, somatic concerns, and hoarding obsessions showed significantly smaller reductions in Y-BOCS severity scores. Conclusions EX/RP was effective for all symptom dimensions, however it was less effective for unacceptable/taboo thoughts and hoarding than for other dimensions. Clinical implications and directions for research are discussed. PMID:24983796

  9. Shrinking of core neoclassical tearing mode magnetic islands due to edge localized modes and the role of ion-scale turbulence in island recovery in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardóczi, Laszlo; Rhodes, Terry L.; Carter, Troy A.

    Experimental signature of long-wavelength turbulence accelerating the recovery of Neoclassical Tearing Mode (NTM) magnetic islands after they have been transiently reduced in size due to inter- action with Edge Localized Modes (ELMs) is reported for the first time. This work shows that per- turbations associated with ELMs result in peaking of the electron temperature (Te) in the O-point region of saturated core m/n 1/4 2/1 islands (m/n being the poloidal/toroidal mode numbers). In syn- chronization with this Te peak, the island width shrinks by as much as 30% suggesting a key role of the Te peak in NTM stability duemore » to modified pressure gradient (rp) and perturbed bootstrap cur- rent (djBS) at the O-point. Next, this Te peak relaxes via anomalous transport (i.e., the diffusivity is 2 orders of magnitude larger than the neoclassical value) and the island recovers. Long-wavelength turbulent density fluctuations (n~) are reduced at the O-point of flat islands but these fluctuations are increased when Te is peaked which offers an explanation for the observed anomalous transport that is responsible for the relaxation of the Te peak. Linear gyrokinetic simulations indicate that n~ inside the peaked island is dominantly driven by the Ion Temperature Gradient instability. These measure- ments suggest that n~ accelerates NTM recovery after an ELM crash via accelerating the relaxation of rp at the O-point. These observations are qualitatively replicated by coupled predator-prey equations and modified Rutherford equation. In this simple model, turbulence accelerates NTM recovery via relaxing rp and therefore restoring djBS at the O-point. The key physics of the rela- tionship between the Te peak and NTM stability has potentially far-reaching consequences, such as NTM control via pellet injection in high-b tokamak plasmas.« less

  10. Shrinking of core neoclassical tearing mode magnetic islands due to edge localized modes and the role of ion-scale turbulence in island recovery in DIII-D

    DOE PAGES

    Bardóczi, Laszlo; Rhodes, Terry L.; Carter, Troy A.; ...

    2017-06-08

    Experimental signature of long-wavelength turbulence accelerating the recovery of Neoclassical Tearing Mode (NTM) magnetic islands after they have been transiently reduced in size due to inter- action with Edge Localized Modes (ELMs) is reported for the first time. This work shows that per- turbations associated with ELMs result in peaking of the electron temperature (Te) in the O-point region of saturated core m/n 1/4 2/1 islands (m/n being the poloidal/toroidal mode numbers). In syn- chronization with this Te peak, the island width shrinks by as much as 30% suggesting a key role of the Te peak in NTM stability duemore » to modified pressure gradient (rp) and perturbed bootstrap cur- rent (djBS) at the O-point. Next, this Te peak relaxes via anomalous transport (i.e., the diffusivity is 2 orders of magnitude larger than the neoclassical value) and the island recovers. Long-wavelength turbulent density fluctuations (n~) are reduced at the O-point of flat islands but these fluctuations are increased when Te is peaked which offers an explanation for the observed anomalous transport that is responsible for the relaxation of the Te peak. Linear gyrokinetic simulations indicate that n~ inside the peaked island is dominantly driven by the Ion Temperature Gradient instability. These measure- ments suggest that n~ accelerates NTM recovery after an ELM crash via accelerating the relaxation of rp at the O-point. These observations are qualitatively replicated by coupled predator-prey equations and modified Rutherford equation. In this simple model, turbulence accelerates NTM recovery via relaxing rp and therefore restoring djBS at the O-point. The key physics of the rela- tionship between the Te peak and NTM stability has potentially far-reaching consequences, such as NTM control via pellet injection in high-b tokamak plasmas.« less

  11. Sensitivity improvement in hydrophilic interaction chromatography negative mode electrospray ionization mass spectrometry using 2-(2-methoxyethoxy)ethanol as a post-column modifier for non-targeted metabolomics.

    PubMed

    Koch, Wendelin; Forcisi, Sara; Lehmann, Rainer; Schmitt-Kopplin, Philippe

    2014-09-26

    The application of ammonia acetate buffered liquid chromatography (LC) eluents is known to concomitantly lead to ion suppression when electrospray ionization mass spectrometry (ESI-MS) detection is used. In negative ESI mode, post column infusion of 2-(2-methoxyethoxy)ethanol (2-MEE) was shown in the literature to help to compensate this adverse effect occurring in reversed phase liquid chromatography mass spectrometry (RP-LC-MS) analyses. Here a setup of direct infusion and hydrophilic interaction chromatography (HILIC) post-column infusion experiments was established in order to investigate systematically the beneficial effects of 2-MEE. We demonstrate that, 2-MEE can help to improve ESI-MS sensitivity in HILIC too and reveal analyte structure specific behaviors. Our study indicates that 2-MEE especially improves ESI response for small and polar molecules. The ESI response of stable isotope labeled amino acids spiked into biological matrices increases up to 50-fold (i.e. D5-l-glutamic acid) when post column infusion of 2-MEE is applied. A non-targeted analysis of a pooled urine sample via HILIC-ESI-QTOF-MS supports this hypothesis. In direct infusion, the combined application of an ammonia acetate buffered solution together with 2-MEE results in an improved ESI response compared to a non-buffered solution. We observed up to 60-fold increased ESI response of l-lysine. We propose this effect is putatively caused by the formation of smaller ESI droplets and stripping of positive charge from ESI droplets due to evaporation of acetic acid anions. In summary, post-column infusion of 2-MEE especially enhances ESI response of small and polar molecules. Therefore it can be regarded as a valuable add-on in targeted or non-targeted metabolomic HILIC-MS studies since this method sets a focus on this molecule category. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Degradation product characterization of therapeutic oligonucleotides using liquid chromatography mass spectrometry.

    PubMed

    Elzahar, N M; Magdy, N; El-Kosasy, Amira M; Bartlett, Michael G

    2018-05-01

    Synthetic antisense phosphorothioate oligonucleotides (PS) have undergone rapid development as novel therapeutic agents. The increasing significance of this class of drugs requires significant investment in the development of quality control methods. The determination of the many degradation pathways of such complex molecules presents a significant challenge. However, an understanding of the potential impurities that may arise is necessary to continue to advance these powerful new therapeutics. In this study, four different antisense oligonucleotides representing several generations of oligonucleotide therapeutic agents were evaluated under various stress conditions (pH, thermal, and oxidative stress) using ion-pairing reversed-phase liquid chromatography tandem mass spectrometry (IP-RPLC-MS/MS) to provide in-depth characterization and identification of the degradation products. The oligonucleotide samples were stressed under different pH values at 45 and 90 °C. The main degradation products were observed to be losses of nucleotide moieties from the 3'- and 5'-terminus, depurination, formation of terminal phosphorothioates, and production of ribose, ribophosphorothioates (Rp), and phosphoribophosphorothioates (pRp). Moreover, the effects of different concentrations of hydrogen peroxide were studied resulting in primarily extensive desulfurization and subsequent oxidation of the phosphorothioate linkage to produce the corresponding phosphodiester. The reaction kinetics for the degradation of the oligonucleotides under the different stress conditions were studied and were found to follow pseudo-first-order kinetics. Differences in rates exist even for oligonucleotides of similar length but consisting of different sequences. Graphical abstract Identification of degradation products across several generations of oligonucleotide therapeutics using LC-MS.

  13. Quantitative analysis of factor P (Properdin) in monkey serum using immunoaffinity capturing in combination with LC-MS/MS.

    PubMed

    Gao, Xinliu; Lin, Hui; Krantz, Carsten; Garnier, Arlette; Flarakos, Jimmy; Tse, Francis L S; Li, Wenkui

    2016-01-01

    Factor P (Properdin), an endogenous glycoprotein, plays a key role in innate immune defense. Its quantification is important for understanding the pharmacodynamics (PD) of drug candidate(s). In the present work, an immunoaffinity capturing LC-MS/MS method has been developed and validated for the first time for the quantification of factor P in monkey serum with a dynamic range of 125 to 25,000 ng/ml using the calibration standards and QCs prepared in factor P depleted monkey serum. The intra- and inter-run precision was ≤7.2% (CV) and accuracy within ±16.8% (%Bias) across all QC levels evaluated. Results of other evaluations (e.g., stability) all met the acceptance criteria. The validated method was robust and implemented in support of a preclinical PK/PD study.

  14. Stability studies of crude plant material of Bacopa monnieri and quantitative determination of bacopaside I and bacoside A by HPLC.

    PubMed

    Srivastava, Pratibha; Raut, Hema N; Puntambekar, Hemalata M; Desai, Anagha C

    2012-01-01

    Bacopa monnieri (BM) contains several dammarane-type triterpenoid saponins including bacopaside I and bacoside A. These bioactive compounds may be used as chemical markers for the quality control of different BM products used for promoting mental health and intellect. Quantification of bacopaside I and bacoside A in crude plant material of BM stored under the stability study conditions by HPLC. Crude BM samples were stored at long-term (LS; 30°C and 65% RH), accelerated (AS; 40°C and 75% RH) and real-time (RT) study conditions. HPLC of BM extracts was carried out using a LiChroCART Purospher® STAR RP-18 endcapped column along with a guard column, Purospher STAR RP 18e 4.0 4.0 mm 5 µm using a gradient of acetonitrile (A) and water containing 0.05% (v/v) orthophosphoric acid (B) at a flow rate 1.5 mL/min with UV detection at 205 nm. The linear range of bacopaside I and bacoside A was 0.2 to 1 mg/mL. With the help of a regression equation the coefficient of determination (r²) values for bacopaside I and bacoside A were found to be > 0.999 and > 0.994 respectively. Relative standard deviation (RSD) values were < 4.0 for all the concentrations injected (n = 3). The HPLC study indicated that BM samples kept under LS condition are rich in saponin contents as compared with the samples stored under AS and RT study conditions. The study indicated that BM plant material should be used fresh to obtain maximum concentration of active saponins or it should be stored under LS conditions up to 3 months. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Opioid receptor involvement in the effect of AgRP- (83-132) on food intake and food selection.

    PubMed

    Hagan, M M; Rushing, P A; Benoit, S C; Woods, S C; Seeley, R J

    2001-03-01

    Agouti-related peptide (AgRP) is a receptor antagonist of central nervous system (CNS) melanocortin receptors and appears to have an important role in the control of food intake since exogenous CNS administration in rats and overexpression in mice result in profound hyperphagia and weight gain. Given that AgRP is heavily colocalized with neuropeptide Y (NPY) and that orexigenic effects of NPY depend on activity at opioid receptors, we hypothesized that AgRP's food-intake effects are also mediated by opioid receptors. Subthreshold doses of the opioid receptor antagonist naloxone blocked AgRP-induced intake when given simultaneously but not 24 h after AgRP injection. Opioids not only influence food intake but food selection as well. Hence, we tested AgRP's effect to alter food choice between matched diets with differing dietary fat content. AgRP selectively enhanced intake of the high-fat but not the low-fat diet. Additionally, AgRP selectively increased chow intake in rats given ad libitum access to a 20% sucrose solution and standard rat chow. The current results indicate that AgRP influences not only caloric intake but food selection as well and that the early effects of AgRP depend critically on an interaction with opioid receptors.

  16. Self-assembled lecithin/chitosan nanoparticles for oral insulin delivery: preparation and functional evaluation.

    PubMed

    Liu, Liyao; Zhou, Cuiping; Xia, Xuejun; Liu, Yuling

    2016-01-01

    Here, we investigated the formation and functional properties of self-assembled lecithin/chitosan nanoparticles (L/C NPs) loaded with insulin following insulin-phospholipid complex preparation, with the aim of developing a method for oral insulin delivery. Using a modified solvent-injection method, insulin-loaded L/C NPs were obtained by combining insulin-phospholipid complexes with L/C NPs. The nanoparticle size distribution was determined by dynamic light scattering, and morphologies were analyzed by cryogenic transmission electron microscopy. Fourier transform infrared spectroscopy analysis was used to disclose the molecular mechanism of prepared insulin-loaded L/C NPs. Fast ultrafiltration and a reversed-phase high-performance liquid chromatography assay were used to separate free insulin from insulin entrapped in the L/C NPs, as well as to measure the insulin-entrapment and drug-loading efficiencies. The in vitro release profile was obtained, and in vivo hypoglycemic effects were evaluated in streptozotocin-induced diabetic rats. Our results indicated that insulin-containing L/C NPs had a mean size of 180 nm, an insulin-entrapment efficiency of 94%, and an insulin-loading efficiency of 4.5%. Cryogenic transmission electron microscopy observations of insulin-loaded L/C NPs revealed multilamellar structures with a hollow core, encircled by several bilayers. In vitro analysis revealed that insulin release from L/C NPs depended on the L/C ratio. Insulin-loaded L/C NPs orally administered to streptozotocin-induced diabetic rats exerted a significant hypoglycemic effect. The relative pharmacological bioavailability following oral administration of L/C NPs was 6.01%. With the aid of phospholipid-complexation techniques, some hydrophilic peptides, such as insulin, can be successfully entrapped into L/C NPs, which could improve oral bioavailability, time-dependent release, and therapeutic activity.

  17. HIF-1α stabilization reduces retinal degeneration in a mouse model of retinitis pigmentosa.

    PubMed

    Olivares-González, Lorena; Martínez-Fernández de la Cámara, Cristina; Hervás, David; Millán, José María; Rodrigo, Regina

    2018-05-01

    Retinitis pigmentosa (RP) is a group of inherited retinal dystrophies characterized by progressive and irreversible loss of vision due to rod and cone degeneration. Evidence suggests that an inappropriate oxygen level could contribute to its pathogenesis. Rod cell death could increase oxygen concentration, reduce hypoxia-inducible factor 1 (HIF-1α) and contribute to cone cell death. The purposes of this study were: 1) to analyze the temporal profile of HIF-1α, its downstream effectors VEGF, endothelin-1 (ET-1), iNOS, and glucose transporter 1 (GLUT1), and neuroinflammation in retinas of the murine model of rd10 ( retinal degeneration 10) mice with RP; 2) to study oxygen bioavailability in these retinas; and 3) to investigate how stabilizing HIF-1α proteins with dimethyloxaloglycine (DMOG), a prolyl hydroxylase inhibitor, affects retinal degeneration, neuroinflammation, and antioxidant response in rd10 mice. A generalized down-regulation of HIF-1α and its downstream targets was detected in parallel with reactive gliosis, suggesting high oxygen levels during retinal degeneration. At postnatal d 18, DMOG treatment reduced photoreceptor cell death and glial activation. In summary, retinas of rd10 mice seem to be exposed to a hyperoxic environment even at early stages of degeneration. HIF-1α stabilization could have a temporal neuroprotective effect on photoreceptor cell survival, glial activation, and antioxidant response at early stages of RP.-Olivares-González, L., Martínez-Fernández de la Cámara, C., Hervás, D., Millán, J. M., Rodrigo, R. HIF-1α stabilization reduces retinal degeneration in a mouse model of retinitis pigmentosa.

  18. An improved method for fast and selective separation of carotenoids by LC-MS.

    PubMed

    Abate-Pella, Daniel; Freund, Dana M; Slovin, Janet P; Hegeman, Adrian D; Cohen, Jerry D

    2017-11-01

    Carotenoids are a large class of compounds that are biosynthesized by condensation of isoprene units in plants, fungi, bacteria, and some animals. They are characteristically highly conjugated through double bonds, which lead to many isomers as well susceptibility to oxidation and other chemical modifications. Carotenoids are important because of their potent antioxidant activity and are the pigments responsible for color in a wide variety of foods. Human consumption is correlated to many health benefits including prevention of cancer, cardiovascular disease, and age-related disease. Extreme hydrophobicity, poor stability, and low concentration in biological samples make these compounds difficult to analyze and difficult to develop analytical methods for aimed towards identification and quantification. Examples in the literature frequently report the use of exotic stationary phases, solvents, and additives, such as ethyl acetate, dichloromethane, and methyl tert-butyl ether that are incompatible with liquid chromatography mass spectrometry (LC-MS). In order to address these issues, we implemented the use of LC-MS friendly conditions using a low-hydrophobicity cyano-propyl column (Agilent Zorbax SB-CN). We successfully differentiated between isomeric carotenoids by optimizing two gradient methods and using a mixture of 11 standards and LC-MS in positive ionization mode. Three complex biological samples from strawberry leaf, chicken feed supplement, and the photosynthetic bacterium Chloroflexus aurantiacus were analyzed and several carotenoids were resolved in these diverse backgrounds. Our results show this methodology is a significant improvement over other alternatives for analyzing carotenoids because of its ease of use, rapid analysis time, high selectivity, and, most importantly, its compatibility with typical LC-MS conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Stability of 10 mg/mL cefuroxime solution for intracameral injection in commonly used polypropylene syringes and new ready-to-use cyclic olefin copolymer sterile vials using the LC-UV stability-indicating method.

    PubMed

    Feutry, Frédéric; Simon, Nicolas; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Décaudin, Bertrand; Labalette, Pierre; Odou, Pascal

    2016-01-01

    Injecting intracameral cefuroxime has been found beneficial in reducing the risk of postoperative endophthalmitis but its use has been limited through a lack of approved marketing and of ready-to-use single-units as well as the problem of aseptic compounding. Our aim was to assess a new automated primary packaging system which should ensure a higher level of sterility, thanks to its closed, sterile, ready-to-use polymer vial called "Crystal® vial". The chemical stability of a 10 mg/mL cefuroxime solution was compared in 1 mL Crystal® vials and 1 mL Luer-lock polypropylene syringes (actual reference) to eliminate any potential and specific interactions with its cyclic olefin copolymer (COC) body and elastomer stopper. Cefuroxime solution was introduced into vials and syringes and stored at -20 °C, +5 °C and +25°C/60% Relative Humidity. Cefuroxime concentration and the relative amount of the main degradation product (descarbamoyl-cefuroxime) were both determined by an HPLC/UV method indicating stability. Solutions were considered steady if the concentration remained at over 90% of the initial value. In the adapted storage conditions, the evolution of osmolality, pH and sterility was assessed. Stability profiles were identical between vials and syringes in all storage and temperature conditions. The solution was stable (cefuroxime concentration, pH and osmolality) and still sterile for 365 days at -20°C. The concentration fell below 90% after 21 days at +5 °C and after 16 h at +25°C/60%s relative humidity. The COC and thermoplastic elastomer of the vials had no impact on the degradation process confirming its possible use for a ready-to-use cefuroxime solution single-unit dose.

  20. Enhanced Bioaccessibility of Crocetin Sugar Esters from Saffron in Infusions Rich in Natural Phenolic Antioxidants.

    PubMed

    Ordoudi, Stella A; Kyriakoudi, Anastasia; Tsimidou, Maria Z

    2015-09-25

    The present study aims to examine whether and to what extent the bioaccessibility of the major saffron apocarotenoids, namely crocetin sugar esters (CRTSEs), is affected by the presence of strong water-soluble antioxidants, ingredients of the herbs found in commercial tea blends with saffron. An in vitro digestion model was applied to infusions from these products to investigate the possible changes. All of the studied infusions were rich in total phenols (9.9-22.5 mg caffeic acid equivalents/100 mg dry infusion) and presented strong DPPH radical scavenging activity regardless of the composition of the corresponding herbal blends. RP-HPLC-DAD and LC-MS analysis enabled the grouping of the infusions into hydroxycinnamic acid-rich and in flavan-3-ol-rich ones. CRTSEs in herbal tea infusions were found to be significantly more bioaccessible (66.3%-88.6%) than those in the reference saffron infusion (60.9%). The positive role of strong phenolic antioxidants (caffeic acid, rosmarinic acid) on the stability of CRTSEs was also evidenced in model binary mixtures. On the contrary, cinnamic acid, exerting no antioxidant activity, did not have such an effect. Our findings suggest that strong radical scavengers may protect the crocetin sugar esters from oxidation during digestion when present in excess.

  1. Thiol-Disulfide Exchange in Peptides Derived from Human Growth Hormone

    PubMed Central

    Chandrasekhar, Saradha; Epling, Daniel E.; Sophocleous, Andreas M.; Topp, Elizabeth M.

    2014-01-01

    Disulfide bonds stabilize proteins by crosslinking distant regions into a compact three-dimensional structure. They can also participate in hydrolytic and oxidative pathways to form non-native disulfide bonds and other reactive species. Such covalent modifications can contribute to protein aggregation. Here we present experimental data for the mechanism of thiol-disulfide exchange in tryptic peptides derived from human growth hormone in aqueous solution. Reaction kinetics were monitored to investigate the effect of pH (6.0-10.0), temperature (4-50 °C), oxidation suppressants (EDTA and N2 sparging) and peptide secondary structure (amide cyclized vs. open form). The concentrations of free thiol containing peptides, scrambled disulfides and native disulfide-linked peptides generated via thiol-disulfide exchange and oxidation reactions were determined using RP-HPLC and LC-MS. Concentration vs. time data were fitted to a mathematical model using non-linear least squares regression analysis. At all pH values, the model was able to fit the data with R2≥0.95. Excluding oxidation suppressants (EDTA and N2 sparging) resulted in an increase in the formation of scrambled disulfides via oxidative pathways but did not influence the intrinsic rate of thiol-disulfide exchange. In addition, peptide secondary structure was found to influence the rate of thiol-disulfide exchange. PMID:24549831

  2. Facile Fabrication of a PDMS@Stearic Acid-Kaolin Coating on Lignocellulose Composites with Superhydrophobicity and Flame Retardancy

    PubMed Central

    Wang, Zhe; Shen, Xiaoping; Qian, Temeng; Wang, Junjie; Sun, Qingfeng; Jin, Chunde

    2018-01-01

    The disadvantages such as swelling after absorbing water and flammability restrict the widespread applications of lignocellulose composites (LC). Herein, a facile and effective method to fabricate superhydrophobic surfaces with flame retardancy on LC has been investigated by coating polydimethylsiloxane (PDMS) and stearic acid (STA) modified kaolin (KL) particles. The as-prepared coatings on the LC exhibited a good repellency to water (a contact angle = 156°). Owing to the excellent flame retardancy of kaolin particles, the LC coated with PDMS@STA-KL displayed a good flame retardancy during limiting oxygen index and cone calorimeter tests. After the coating treatment, the limiting oxygen index value of the LC increased to 41.0. Cone calorimetry results indicated that the ignition time of the LC coated with PDMS@STA-KL increased by 40 s compared with that of uncoated LC. Moreover, the peak heat release rate (PHRR) and the total heat release (THR) of LC coated with PDMS@STA-KL reduced by 18.7% and 19.2% compared with those of uncoated LC, respectively. This LC coating with improved water repellency and flame retardancy can be considered as a potential alternative to protect the lignocellulose composite. PMID:29751575

  3. Simultaneous and confirmative detection of multi-residues of β₂-agonists and β-blockers in urine using LC-MS/MS/MS coupled with β-receptor molecular imprinted polymer SPE clean-up.

    PubMed

    Fan, S; Zou, J H; Miao, H; Zhao, Y F; Chen, H J; Zhao, R; Wu, Y N

    2013-01-01

    A liquid chromatography-linear ion-trap spectrometry (LC-MS³) method using β-receptor molecular-imprinted polymer (MIP) solid-phase extraction (SPE) as clean-up was developed to determine simultaneously and confirmatively residues of 25 β₂-agonists and 21 β-blockers in urine samples. Urine samples were subjected to enzymatic hydrolysis by β-glucoronidase/arylsulphatase, and then extracted with perchloric acid. Sample clean-up was performed using β-receptor MIP SPE. A Supelco Ascentis® express Rp-Amide column was used to separate the analytes, and MS³ detection used an electrospray ionisation source in positive-ion mode. Recovery studies were carried out using blank urine samples fortified with the 46 analytes at the levels of 0.5, 1.0 and 2.0 μg l⁻¹. Recoveries were obtained ranging from 60.1% to 109.9% with relative standard deviations (RSDs, n = 7) from 0.5% to 19.4%. The limits of detection (LODs) and limits of quantitation (LOQs) of the 46 analytes in urine were 0.02-0.18 and 0.05-0.60 μg l⁻¹, respectively. As a result of the selective clean-up by MIP SPE and MS³ detection of the target drugs, the sensitivity and accuracy of the present method was high enough for monitoring β₂-agonist and β-blocker residues in urine samples. Satisfactory results were obtained in the process of the determination of positive urine samples.

  4. Performance Analysis of AeroRP with Ground Station Advertisements

    DTIC Science & Technology

    2012-03-12

    results showed that AeroRP outperforms the traditional MANET routing protocols in terms of throughput and packet delivery ra - tio (PDR) [5, 6]. AeroRP...and waiting for the source to re- send the packet increases the end-to-end delay. The AeroNP corruption indicator and HEC -CRC (header error check...Dev ID | NP HEC CRC-16 | +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+ \\ \\ / AeroTP Payload

  5. Langerhans cells from women with cervical precancerous lesions become functionally responsive against human papillomavirus after activation with stabilized Poly-I:C.

    PubMed

    Da Silva, Diane M; Woodham, Andrew W; Skeate, Joseph G; Rijkee, Laurie K; Taylor, Julia R; Brand, Heike E; Muderspach, Laila I; Roman, Lynda D; Yessaian, Annie A; Pham, Huyen Q; Matsuo, Koji; Lin, Yvonne G; McKee, Greg M; Salazar, Andres M; Kast, W Martin

    2015-12-01

    Human papillomavirus (HPV)-mediated suppression of Langerhans cell (LC) function can lead to persistent infection and development of cervical intraepithelial neoplasia (CIN). Women with HPV-induced high-grade CIN2/3 have not mounted an effective immune response against HPV, yet it is unknown if LC-mediated T cell activation from such women is functionally impaired against HPV. We investigated the functional activation of in vitro generated LC and their ability to induce HPV16-specific T cells from CIN2/3 patients after exposure to HPV16 followed by treatment with stabilized Poly-I:C (s-Poly-I:C). LC from patients exposed to HPV16 demonstrated a lack of costimulatory molecule expression, inflammatory cytokine secretion, and chemokine-directed migration. Conversely, s-Poly-I:C caused significant phenotypic and functional activation of HPV16-exposed LC, which resulted in de novo generation of HPV16-specific CD8(+) T cells. Our results highlight that LC of women with a history of persistent HPV infection can present HPV antigens and are capable of inducing an adaptive T cell immune response when given the proper stimulus, suggesting that s-Poly-I:C compounds may be attractive immunomodulators for LC-mediated clearance of persistent HPV infection. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Multivalency regulates activity in an intrinsically disordered transcription factor

    PubMed Central

    Clark, Sarah; Myers, Janette B; King, Ashleigh; Fiala, Radovan; Novacek, Jiri; Pearce, Grant; Heierhorst, Jörg; Reichow, Steve L

    2018-01-01

    The transcription factor ASCIZ (ATMIN, ZNF822) has an unusually high number of recognition motifs for the product of its main target gene, the hub protein LC8 (DYNLL1). Using a combination of biophysical methods, structural analysis by NMR and electron microscopy, and cellular transcription assays, we developed a model that proposes a concerted role of intrinsic disorder and multiple LC8 binding events in regulating LC8 transcription. We demonstrate that the long intrinsically disordered C-terminal domain of ASCIZ binds LC8 to form a dynamic ensemble of complexes with a gradient of transcriptional activity that is inversely proportional to LC8 occupancy. The preference for low occupancy complexes at saturating LC8 concentrations with both human and Drosophila ASCIZ indicates that negative cooperativity is an important feature of ASCIZ-LC8 interactions. The prevalence of intrinsic disorder and multivalency among transcription factors suggests that formation of heterogeneous, dynamic complexes is a widespread mechanism for tuning transcriptional regulation. PMID:29714690

  7. Rapid and reliable quantitation of amino acids and myo-inositol in mouse brain by high performance liquid chromatography and tandem mass spectrometry.

    PubMed

    Bathena, Sai P; Huang, Jiangeng; Epstein, Adrian A; Gendelman, Howard E; Boska, Michael D; Alnouti, Yazen

    2012-04-15

    Amino acids and myo-inositol have long been proposed as putative biomarkers for neurodegenerative diseases. Accurate measures and stability have precluded their selective use. To this end, a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method based on multiple reaction monitoring was developed to simultaneously quantify glutamine, glutamate, γ-aminobutyric acid (GABA), aspartic acid, N-acetyl aspartic acid, taurine, choline, creatine, phosphocholine and myo-inositol in mouse brain by methanol extractions. Chromatography was performed using a hydrophilic interaction chromatography silica column within in a total run time of 15 min. The validated method is selective, sensitive, accurate, and precise. The method has a limit of quantification ranging from 2.5 to 20 ng/ml for a range of analytes and a dynamic range from 2.5-20 to 500-4000 ng/ml. This LC-MS/MS method was validated for biomarker discovery in models of human neurological disorders. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices

    PubMed Central

    ARMSTRONG, JENNA L.; DILLS, RUSSELL L.; YU, JIANBO; YOST, MICHAEL G.; FENSKE, RICHARD A.

    2018-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15–1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78–113% from XAD-2 active air sampling tubes and 71–108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74–94% after time periods ranging from 2–10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method. PMID:24328542

  9. A sensitive LC-MS/MS method for measurement of organophosphorus pesticides and their oxygen analogs in air sampling matrices.

    PubMed

    Armstrong, Jenna L; Dills, Russell L; Yu, Jianbo; Yost, Michael G; Fenske, Richard A

    2014-01-01

    A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed for determination of levels of the organophosphorus (OP) pesticides chlorpyrifos (CPF), azinphos methyl (AZM), and their oxygen analogs chlorpyrifos-oxon (CPF-O) and azinphos methyl-oxon (AZM-O) on common active air sampling matrices. XAD-2 resin and polyurethane foam (PUF) matrices were extracted with acetonitrile containing stable-isotope labeled internal standards (ISTD). Analysis was accomplished in Multiple Reaction Monitoring (MRM) mode, and analytes in unknown samples were identified by retention time (±0.1 min) and qualifier ratio (±30% absolute) as compared to the mean of calibrants. For all compounds, calibration linearity correlation coefficients were ≥0.996. Limits of detection (LOD) ranged from 0.15-1.1 ng/sample for CPF, CPF-O, AZM, and AZM-O on active sampling matrices. Spiked fortification recoveries were 78-113% from XAD-2 active air sampling tubes and 71-108% from PUF active air sampling tubes. Storage stability tests also yielded recoveries ranging from 74-94% after time periods ranging from 2-10 months. The results demonstrate that LC-MS/MS is a sensitive method for determining these compounds from two different matrices at the low concentrations that can result from spray drift and long range transport in non-target areas following agricultural applications. In an inter-laboratory comparison, the limit of quantification (LOQ) for LC-MS/MS was 100 times lower than a typical gas chromatography-mass spectrometry (GC-MS) method.

  10. The possible crossover effects of NaNO3 confined in porous media: From bulk to clusters

    NASA Astrophysics Data System (ADS)

    Mu, R.; Jin, F.; Morgan, S. H.; Henderson, D. O.; Silberman, E.

    1994-05-01

    Differential scanning calorimetry (DSC) and Raman spectra are reported for NaNO3 bulk and for NaNO3 confined in porous silica with pore radii, rp=2.5, 5, 10, 20 nm. Raman spectra are also given for a 6 M solution of NaNO3. The melting transition for the confined NaNO3 exhibits a 1/rp dependence where rp is the pore radius for rp≳5 nm. No melting transition is observed for NaNO3 confined in 2.5 nm pores. Above this pore size, their appears to be a deviation in the melting transition dependence on rp. The internal modes observed in the Raman spectra for the confined material are in agreement with those of the bulk solid except for a feature observed on the low frequency side of the ν1 band. The external TO mode observed at 100 cm-1 and the librational mode at 175 cm-1 for NaNO3 both decrease in intensity and broaden as rp decreases and both bands disappear at rp=2.5 nm. An additional peak at 70 cm-1 not observed in the solution or bulk NaNO3 spectra appears in the spectra of confined NaNO3 and increases in intensity as rp decreases. We assign this band to a new phase of NaNO3 which is stabilized by the surface hydroxyl groups of the porous silica. For NaNO3 confined in pores, rp≤2.5 nm, we suggest that NaNO3 exists as disordered aggregates.

  11. Fractionation and identification of novel antioxidant peptides from buffalo and bovine casein hydrolysates.

    PubMed

    Shazly, Ahmed Behdal; He, Zhiyong; El-Aziz, Mahmoud Abd; Zeng, Maomao; Zhang, Shuang; Qin, Fang; Chen, Jie

    2017-10-01

    Buffalo and bovine caseins were hydrolysed by alcalase and trypsin to produce novel antioxidant peptides. The casein hydrolysates were purified using ultrafiltration (UF) and further characterized by RP-HPLC. The fractions produced higher antioxidant activities were identified for their peptides using LC MS/MS. All UF-VI (MW<1kDa) fractions showed higher antioxidant activity. Hydrolysate produced by alcalase for buffalo casein (UF-VI with 54.84-fold purification) showed higher antioxidant activity than that obtained by trypsin. Trypsin hydrolysate contained high amount of hydrophobic amino acids while alcalase hydrolysate consisted mainly of Ser, Arg, Ala and Leu. The antioxidant peptides identified by LC MS/MS were RELEE, MEDNKQ and TVA, EQL in buffalo casein hydrolysates produced by trypsin and alcalase, respectively. Mechanism and reaction pathways of selected antioxidant peptides with ABTS were proposed. Conclusively, buffalo casein provided antioxidant peptides similar to bovine, suggesting that buffalo casein is a novel source of antioxidant. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. RP5063, an atypical antipsychotic drug with a unique pharmacologic profile, improves declarative memory and psychosis in mouse models of schizophrenia.

    PubMed

    Rajagopal, Lakshmi; Kwon, Sunoh; Huang, Mei; Michael, Eric; Bhat, Laxminarayan; Cantillon, Marc; Meltzer, Herbert Y

    2017-08-14

    Various types of atypical antipsychotic drugs (AAPDs) modestly improve the cognitive impairment associated with schizophrenia (CIAS). RP5063 is an AAPD with a diverse and unique pharmacology, including partial agonism at dopamine (DA) D 2 , D 3 , D 4 , serotonin (5-HT) 1A , and 5-HT 2A receptors (Rs), full agonism at α 4 β 2 nicotinic acetylcholine (ACh)R (nAChR), and antagonism at 5-HT 2B , 5-HT 6 , and 5-HT 7 Rs. Most atypical APDs are 5-HT 2A inverse agonists. The efficacy of RP5063 in mouse models of psychosis and episodic memory were studied. RP5063 blocked acute phencyclidine (PCP)-as well as amphetamine-induced hyperactivity, indicating antipsychotic activity. Acute administration of RP5063 significantly reversed subchronic (sc)PCP-induced impairment in novel object recognition (NOR), a measure of episodic memory, but not reversal learning, a measure of executive function. Co-administration of a sub-effective dose (SED) of RP5063 with SEDs of a 5-HT 7 R antagonist, a 5-HT 1B R antagonist, a 5-HT 2A R inverse agonist, or an α 4 β 2 nAChR agonist, restored the ability of RP5063 to ameliorate the NOR deficit in scPCP mice. Pre-treatment with a 5-HT 1A R, a D 4 R, antagonist, but not an α 4 β 2 nAChR antagonist, blocked the ameliorating effect of RP5063. Further, co-administration of scRP5063 prior to each dose of PCP prevented the effect of PCP to produce a deficit in NOR for one week. RP5063, given to scPCP-treated mice for one week restored NOR for one week only. Acute administration of RP5063 significantly increased cortical DA efflux, which may be critical to some of its cognitive enhancing properties. These results indicate that RP5063, by itself, or as an adjunctive treatment has a multifaceted basis for improving some cognitive deficits associated with schizophrenia. Copyright © 2017. Published by Elsevier B.V.

  13. Detection of novel mutations that cause autosomal dominant retinitis pigmentosa in candidate genes by long-range PCR amplification and next-generation sequencing

    PubMed Central

    Dias, Miguel de Sousa; Hernan, Imma; Pascual, Beatriz; Borràs, Emma; Mañé, Begoña; Gamundi, Maria José

    2013-01-01

    Purpose To devise an effective method for detecting mutations in 12 genes (CA4, CRX, IMPDH1, NR2E3, RP9, PRPF3, PRPF8, PRPF31, PRPH2, RHO, RP1, and TOPORS) commonly associated with autosomal dominant retinitis pigmentosa (adRP) that account for more than 95% of known mutations. Methods We used long-range PCR (LR-PCR) amplification and next-generation sequencing (NGS) performed in a GS Junior 454 benchtop sequencing platform. Twenty LR-PCR fragments, between 3,000 and 10,000 bp, containing all coding exons and flanking regions of the 12 genes, were obtained from DNA samples of patients with adRP. Sequencing libraries were prepared with an enzymatic (Fragmentase technology) method. Results Complete coverage of the coding and flanking sequences of the 12 genes assayed was obtained with NGS, with an average sequence depth of 380× (ranging from 128× to 1,077×). Five previous known mutations in the adRP genes were detected with a sequence variation percentage between 35% and 65%. We also performed a parallel sequence analysis of four samples, three of them new patients with index adRP, in which two novel mutations were detected in RHO (p.Asn73del) and PRPF31 (p.Ile109del). Conclusions The results demonstrate that genomic LR-PCR amplification together with NGS is an effective method for analyzing individual patient samples for mutations in a monogenic heterogeneous disease such as adRP. This approach proved effective for the parallel analysis of adRP and has been introduced as routine. Additionally, this approach could be extended to other heterogeneous genetic diseases. PMID:23559859

  14. Simultaneous determination of water-soluble vitamins in SRM 1849 Infant/Adult Nutritional Formula powder by liquid chromatography-isotope dilution mass spectrometry.

    PubMed

    Goldschmidt, Robert J; Wolf, Wayne R

    2010-05-01

    Assessing dietary intake of vitamins from all sources, including foods, dietary supplements, and fortified foods, would be aided considerably by having analytical methodologies that are capable of simultaneous determination of several vitamins. Vitamins naturally present in foods may occur in different chemical forms, with levels ranging over several orders of magnitude. Vitamins in dietary supplements and fortified foods, however, are typically added in a single chemical form, and matrix issues are usually not as complex. These sources should thus be relatively amenable to approaches that aim for simultaneous determination of multiple vitamins. Our recent work has focused on development of liquid chromatography (LC)-UV/fluorescence and LC-tandem mass spectrometry methods for the simultaneous determination of water-soluble vitamins (thiamine, niacin, pyridoxine, pantothenic acid, folic acid, biotin, and riboflavin) in dietary supplement tablets and fortified foods, such as formula powders and breakfast cereals. As part of the validation of our methods and collaboration in characterization of a new NIST SRM 1849 Infant/Adult Nutritional Formula powder, we report data on SRM 1849 using isotope dilution mass spectrometric methods. Use of available NIST Standard Reference Materials(R) as test matrices in our method development and validation gives a benchmark for future application of these methods. We compare three chromatographic approaches and provide data on stability of vitamin standard solutions for LC-based multiple vitamin determinations.

  15. Stability-Indicating Related Substances HPLC Method for Droxidopa and Characterization of Related Substances Using LC-MS and NMR.

    PubMed

    Kumar, Thangarathinam; Ramya, Mohandass; Arockiasamy Xavier, S J

    2016-11-01

    Stress degradation studies using high-performance liquid chromatography (HPLC) was performed and validated for Droxidopa (L-DOPS). Droxidopa was susceptible to acid hydrolysis (0.1 N HCl), alkaline hydrolysis (0.15 N NaOH) and thermal degradation (105°C). It was found to be resistant to white light, oxidation and UV light exposure (72 h). The thermal, acid and alkali degradation impurities were detected with the retention time (RT) of 12.7, 19.25 and 22.95 min. Our HPLC method detected process impurities (2R,3R)-2-amino-3-(3,4-dihydroxyphenyl)-3-hydroxypropionic acid (Impurity H), N-Hydroxypthalimide (Impurity N), (2R,3S)-2-amino-3-(benzo[d][1,3]dioxol-5-yl)-3-hydroxypropionic acid (Impurity L) and L-threo n-phthaloyl-3-(3, 4-dihydroxyphenyl)-serine (Intermediate) with RTs of 3.48, 15.5, 25.76 and 28.0 min. The related substances were further characterized and confirmed by liquid chromatography-mass spectroscopy (LC-MS), and nuclear magnetic resonance spectroscopy analysis. Our HPLC method detected up to 0.05 µg/mL of Droxidopa with S/N > 3.0 and quantified up to 0.10 µg /mL of Droxidopa with S/N ratio > 10.0. Droxidopa was highly stable for 12 h after its preparation for HPLC analysis. Our newly developed HPLC method was highly precise, specific, reliable and accurate for the analysis of Droxidopa and its related substances. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica

    PubMed Central

    Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748

  17. Rapid Development and Validation of Improved Reversed-Phase High-performance Liquid Chromatography Method for the Quantification of Mangiferin, a Polyphenol Xanthone Glycoside in Mangifera indica.

    PubMed

    Naveen, P; Lingaraju, H B; Prasad, K Shyam

    2017-01-01

    Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.

  18. Development and stability of semisolid preparations based on a supercritical CO2 Arnica extract.

    PubMed

    Bilia, Anna Rita; Bergonzi, Maria Camilla; Mazzi, Giovanni; Vincieri, Franco Francesco

    2006-05-03

    Conventional herbal drug preparations (HDP) based on Arnica montana L. have a low content of the active principles, sesquiterpene lactones, which show poor stability and low physical compatibility in semisolid formulations. Recently, an innovative supercritical carbon dioxide (CO2) extract with high sesquiterpene content has been marketed. Development of six semisolid preparations (cetomacrogol, polysorbate 60, polawax, anphyphil, natrosol and sepigel) based on this innovative CO2 extract is discussed. Stability of these preparations was investigated according to ICH guidelines. The evaluation of in vitro release of active constituents was performed using the cell method reported in the European Pharmacopoeia. Preliminary data on in vivo permeation of three selected formulations is demonstrated using the "skin stripping" test, according to the FDA, in healthy subjects. Analysis of sesquiterpene lactones within the extract and in vitro and in vivo studies was performed by RP-HPLC-DAD-MS method. The cetomacrogol showed the best release profile in the in vitro test, while in the in vivo test the best preparation resulted polysorbate 60 and polawax.

  19. Determination of pterins in urine by HPLC with UV and fluorescent detection using different types of chromatographic stationary phases (HILIC, RP C8, RP C18).

    PubMed

    Kośliński, Piotr; Jarzemski, Piotr; Markuszewski, Michał J; Kaliszan, Roman

    2014-03-01

    Pterins are a class of potential cancer biomarkers. New methods involving hydrophilic interaction liquid chromatography (HILIC) and reversed phase (RP) high-performance liquid chromatography have been developed for analysis of eight pterin compounds: 6,7-dimethylpterin, pterin, 6-OH-methylpterin, biopterin, isoxanthopterin, neopterin, xanthopterin, and pterin-6-carboxylic acid. The effect of mobile phase composition, buffer type, pH and concentration on retention using HILIC, C8 and C18 RP stationary phases were examined. Separation of pterins on RP and HILIC stationary phase was performed and optimized. Eight pterins were successfully separated on HILIC Luna diol-bonded phases, Aquasil C18 RP column and LiChrospher C8 RP column. Determination and separation of the pterins from urine samples were performed on HILIC Luna and LiChrospher C8 RP columns which were chosen as the most appropriate ones. Finally, LiChrospher C8 RP column with fluorescence detection was selected for further validation of the method. The optimum chromatographic condition was mobile phase methanol (A)/phosphoric buffer pH 7, 10mM (B), isocratic elution 0-15min 5% A flow=0.5ml/min 15-17min. 5% A, flow=0.5-1ml/min the linearity (R(2)>0.997) and retention time repeatability (RSD%<1) were at satisfactory level. The precision of peak areas expressed as RSD in % was between 0.55 and 14. Pterins detection limits varied from 0.041ng/ml to 2.9ng/ml. Finally, HPLC method was used for the analysis of pterins in urine samples with two different oxidation procedures. Concentration levels of pterin compounds in bladder cancer patients and healthy subjects were compared. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Analytical techniques and method validation for the measurement of selected semivolatile and nonvolatile organofluorochemicals in air.

    PubMed

    Reagen, William K; Lindstrom, Kent R; Thompson, Kathy L; Flaherty, John M

    2004-09-01

    The widespread use of semi- and nonvolatile organofluorochemicals in industrial facilities, concern about their persistence, and relatively recent advancements in liquid chromatography/mass spectrometry (LC/MS) technology have led to the development of new analytical methods to assess potential worker exposure to airborne organofluorochemicals. Techniques were evaluated for the determination of 19 organofluorochemicals and for total fluorine in ambient air samples. Due to the potential biphasic nature of most of these fluorochemicals when airborne, Occupational Safety and Health Administration (OSHA) versatile sampler (OVS) tubes were used to simultaneously trap fluorochemical particulates and vapors from workplace air. Analytical methods were developed for OVS air samples to quantitatively analyze for total fluorine using oxygen bomb combustion/ion selective electrode and for 17 organofluorochemicals using LC/MS and gas chromatography/mass spectrometry (GC/MS). The experimental design for this validation was based on the National Institute of Occupational Safety and Health (NIOSH) Guidelines for Air Sampling and Analytical Method Development and Evaluation, with some revisions of the experimental design. The study design incorporated experiments to determine analytical recovery and stability, sampler capacity, the effect of some environmental parameters on recoveries, storage stability, limits of detection, precision, and accuracy. Fluorochemical mixtures were spiked onto each OVS tube over a range of 0.06-6 microg for each of 12 compounds analyzed by LC/MS and 0.3-30 microg for 5 compounds analyzed by GC/MS. These ranges allowed reliable quantitation at 0.001-0.1 mg/m3 in general for LC/MS analytes and 0.005-0.5 mg/m3 for GC/MS analytes when 60 L of air are sampled. The organofluorochemical exposure guideline (EG) is currently 0.1 mg/m3 for many analytes, with one exception being ammonium perfluorooctanoate (EG is 0.01 mg/m3). Total fluorine results may be used to determine if the individual compounds quantified provide a suitable mass balance of total airborne organofluorochemicals based on known fluorine content. Improvements in precision and/or recovery as well as some additional testing would be needed to meet all NIOSH validation criteria. This study provided valuable information about the accuracy of this method for organofluorochemical exposure assessment.

  1. Identification of four new degradation products of epirubicin through forced degradation, LC-UV, MSn and LC-MS-TOF studies.

    PubMed

    Kaushik, Dheeraj; Saini, Balraj; Bansal, Gulshan

    2015-01-01

    Epirubicin (EPI) was subjected to International Conference on Harmonization recommended forced degradation under the conditions of hydrolysis, oxidation, dry heat and photolysis to characterize its possible impurities and/or degradation products. The drug was found highly unstable to alkaline hydrolysis even at room temperature, unstable to acid hydrolysis at 80°C and to oxidation at room temperature. The hydrolytic and oxidative degradation products were resolved on an Agilent RP8 (150 mm × 4.6 mm; 5 µm) column with isocratic elution using mobile phase composed of ammonium formate (10 mM, pH 3.0), acetonitrile and methanol. The drug degraded to four oxidative products (O-I, O-II, O-III and O-IV) and to one acid hydrolyzed product (A-I). Purity of each peak in liquid chromatography-ultraviolet (LC-UV) chromatogram was ascertained through photodiode array (LC-PDA) analysis. The products were characterized through electrospray ionization-mass spectrometry (+ESI-MS(n)) studies on EPI and liquid chromatography-time of flight mass spectrometry (LC-MS-TOF) studies on degraded drug solutions. The products, O-I-O-IV, were characterized as 2-hydroxy-8-desacetylepirubicin-8-hydroperoxide, 4-hydroxy-8-desacetylepirubicin-8-hydroperoxide, 8-desacetylepirubicin-8-hydroperoxide and 8-desacetylepirubicin, respectively, and product A-I was characterized as deglucosaminylepirubicin. While A-I was found to be a pharmacopoeial impurity, all oxidative products were found to be new degradation impurities. The mechanisms and pathways of degradation of EPI were discussed and outlined. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Comparative study on toxicity of methylmercury chloride and methylmercury hydroxide to the human neuroblastoma cell line SH-SY5Y.

    PubMed

    Patnaik, Rajashree; Padhy, Rabindra N

    2018-05-11

    Toxicities of methylmercury chloride (CH 3 HgCl) and methylmercury hydroxide (CH 3 HgOH) to cultured neuroblastoma cell line SH-SY5Y in vitro are evaluated. This is the comparative study between two methylmercury compounds to find out the extent of toxicity of these compounds are toxic to SH-SY5Y cell line. Both cytotoxicity and genotoxicity experiments were carried out to find out the more toxic compound. For cytotoxicity study, four staining assay methods independently with trypan blue (TB), acridine orange/ethidium bromide (AO/EB), 3-(4,5-dimethylthiazol-2-yl) 2,5-diphenyl tetrazolium bromide (MTT), and neutral red (NR) were used and the comet assay method was done for genotoxicity study. The obtained toxicity data were used for probit analysis. In cytotoxicity, CH 3 HgCl had minimum inhibitory concentration (MIC) value in each assay method as 3 mg/L invariably; LC 25 values were in the range 7.41 to 10.23 mg/L, and LC 50 values were 14.79 to 15.48 mg/L; while LC 75 values were 20.89 to 26.91 mg/L. Moreover, LC 100 value was 30 mg/L, known from comet assay experiments for CH 3 HgCl. Similarly for CH 3 HgOH, the MIC value in each assay method was invariably 3 mg/L, the LC 25 values were in the range 12.58 to 16.59 mg/L, and LC 50 values were 19.49 to 23.44 mg/L; LC 75 values were 27.54 to 30.90 mg/L and LC 100 value was 42 mg/L in each assay done for cytotoxicity and genotoxicity studies. Computed DNA fragmentation indices in comet assays were 98.6 ± 0.57 30 mg/L with CH 3 HgCl and 76 ± 5.29 30 mg/L with CH 3 HgOH. This study clearly indicated that methylmercury chloride is more toxic than methylmercury hydroxide to SH-SY5Y cell line. Toxicity of Hg had been quantified with in vitro cultured human neuroblastoma cell line; since it has neurotoxic effects, its neural evaluation has implications in environmental health issues.

  3. Analysis of host-cell proteins in biotherapeutic proteins by comprehensive online two-dimensional liquid chromatography/mass spectrometry

    PubMed Central

    Xenopoulos, Alex; Fadgen, Keith; Murphy, Jim; Skilton, St. John; Prentice, Holly; Stapels, Martha

    2012-01-01

    Assays for identification and quantification of host-cell proteins (HCPs) in biotherapeutic proteins over 5 orders of magnitude in concentration are presented. The HCP assays consist of two types: HCP identification using comprehensive online two-dimensional liquid chromatography coupled with high resolution mass spectrometry (2D-LC/MS), followed by high-throughput HCP quantification by liquid chromatography, multiple reaction monitoring (LC-MRM). The former is described as a “discovery” assay, the latter as a “monitoring” assay. Purified biotherapeutic proteins (e.g., monoclonal antibodies) were digested with trypsin after reduction and alkylation, and the digests were fractionated using reversed-phase (RP) chromatography at high pH (pH 10) by a step gradient in the first dimension, followed by a high-resolution separation at low pH (pH 2.5) in the second dimension. As peptides eluted from the second dimension, a quadrupole time-of-flight mass spectrometer was used to detect the peptides and their fragments simultaneously by alternating the collision cell energy between a low and an elevated energy (MSE methodology). The MSE data was used to identify and quantify the proteins in the mixture using a proven label-free quantification technique (“Hi3” method). The same data set was mined to subsequently develop target peptides and transitions for monitoring the concentration of selected HCPs on a triple quadrupole mass spectrometer in a high-throughput manner (20 min LC-MRM analysis). This analytical methodology was applied to the identification and quantification of low-abundance HCPs in six samples of PTG1, a recombinant chimeric anti-phosphotyrosine monoclonal antibody (mAb). Thirty three HCPs were identified in total from the PTG1 samples among which 21 HCP isoforms were selected for MRM monitoring. The absolute quantification of three selected HCPs was undertaken on two different LC-MRM platforms after spiking isotopically labeled peptides in the samples. Finally, the MRM quantitation results were compared with TOF-based quantification based on the Hi3 peptides, and the TOF and MRM data sets correlated reasonably well. The results show that the assays provide detailed valuable information to understand the relative contributions of purification schemes to the nature and concentrations of HCP impurities in biopharmaceutical samples, and the assays can be used as generic methods for HCP analysis in the biopharmaceutical industry. PMID:22327428

  4. Phosphorylated ribosomal S6 (p-rpS6) as a post-treatment indicator of HER2 signalling targeted drug resistance.

    PubMed

    Yang-Kolodji, Gloria; Mumenthaler, Shannon M; Mehta, Arjun; Ji, Lingyun; Tripathy, Debu

    2015-01-01

    To identify clinically relevant predictive biomarkers of trastuzumab resistance. MTT, FACS assays, immunoblotting and immunocytochemistry were used to phenotypically characterize drug responses of two cell models BT474R and SKBR3R. Student's t-test and Spearman's correlation were applied for statistic analysis. The activity of a downstream effector of the HER2 pathway phosphorylated ribosomal protein S6 (p-rpS6), was suppressed by trastuzumab in the parental cell lines yet remained unchanged in the resistant cells following treatment. The level of p-rpS6 was inversely correlated to the drug induced growth inhibition of trastuzumab-resistant cells when they are treated with selected HER2 targeting drugs. p-rpS6 is a robust post-treatment indicator of HER2 pathway-targeted therapy resistance.

  5. Discovery of recombining plasma from the faintest GeV supernova remnant HB 21 and a possible scenario for cosmic rays escaping from supernova remnant shocks

    NASA Astrophysics Data System (ADS)

    Suzuki, Hiromasa; Bamba, Aya; Nakazawa, Kazuhiro; Furuta, Yoshihiro; Sawada, Makoto; Yamazaki, Ryo; Koyama, Katsuji

    2018-06-01

    We present an X-ray study of the GeV gamma-ray supernova remnant (SNR) HB 21 with Suzaku. HB 21 is interacting with molecular clouds, and is the faintest in the GeV band among known GeV SNRs. We discovered strong radiative recombination continua of Si and S from the center of the remnant, which provide direct evidence of a recombining plasma (RP). The total emission can be explained with the RP and ionizing plasma components. The electron temperature and recombination timescale of the RP component were estimated as 0.17 (0.15-0.18) keV and 3.2 (2.0-4.8) × 1011 s cm-3, respectively. The estimated age of the RP (˜170 kyr) is the longest among known recombining GeV SNRs, because of a very low density of electrons (˜0.05 cm-3). We have examined the dependencies of GeV spectral indices on each of RP ages and SNR diameters for nine recombining GeV SNRs. Both showed possible positive correlations, indicating that both the parameters can be good indicators of properties of accelerated protons, for instance the degree of escape from SNR shocks. A possible scenario for a process of proton escape is introduced: interaction with molecular clouds makes weaker magnetic turbulence and cosmic-ray protons escape, simultaneously cooling down the thermal electrons and generating an RP.

  6. Sunitinib induces genomic instability of renal carcinoma cells through affecting the interaction of LC3-II and PARP-1.

    PubMed

    Yan, Siyuan; Liu, Ling; Ren, Fengxia; Gao, Quan; Xu, Shanshan; Hou, Bolin; Wang, Yange; Jiang, Xuejun; Che, Yongsheng

    2017-08-10

    Deficiency of autophagy has been linked to increase in nuclear instability, but the role of autophagy in regulating the formation and elimination of micronuclei, a diagnostic marker for genomic instability, is limited in mammalian cells. Utilizing immunostaining and subcellular fractionation, we found that either LC3-II or the phosphorylated Ulk1 localized in nuclei, and immunoprecipitation results showed that both LC3 and Unc-51-like kinase 1 (Ulk1) interacted with γ-H2AX, a marker for the DNA double-strand breaks (DSB). Sunitinib, a multi-targeted receptor tyrosine kinase inhibitor, was found to enhance the autophagic flux concurring with increase in the frequency of micronuclei accrued upon inhibition of autophagy, and similar results were also obtained in the rasfonin-treated cells. Moreover, the punctate LC3 staining colocalized with micronuclei. Unexpectedly, deprivation of SQSTM1/p62 alone accumulated micronuclei, which was not further increased upon challenge with ST. Rad51 is a protein central to repairing DSB by homologous recombination and treatment with ST or rasfonin decreased its expression. In several cell lines, p62 appeared in the immunoprecipites of Rad51, whereas LC3, Ulk1 and p62 interacted with PARP-1, another protein involved in DNA repair and genomic stability. In addition, knockdown of either Rad51 or PARP-1 completely inhibited the ST-induced autophagic flux. Taken together, the data presented here demonstrated that both LC3-II and the phosphorylated Ulk1 localized in nuclei and interacted with the proteins essential for nuclear stability, thereby revealing a more intimate relationship between autophagy and genomic stability.

  7. Sunitinib induces genomic instability of renal carcinoma cells through affecting the interaction of LC3-II and PARP-1

    PubMed Central

    Yan, Siyuan; Liu, Ling; Ren, Fengxia; Gao, Quan; Xu, Shanshan; Hou, Bolin; Wang, Yange; Jiang, Xuejun; Che, Yongsheng

    2017-01-01

    Deficiency of autophagy has been linked to increase in nuclear instability, but the role of autophagy in regulating the formation and elimination of micronuclei, a diagnostic marker for genomic instability, is limited in mammalian cells. Utilizing immunostaining and subcellular fractionation, we found that either LC3-II or the phosphorylated Ulk1 localized in nuclei, and immunoprecipitation results showed that both LC3 and Unc-51-like kinase 1 (Ulk1) interacted with γ-H2AX, a marker for the DNA double-strand breaks (DSB). Sunitinib, a multi-targeted receptor tyrosine kinase inhibitor, was found to enhance the autophagic flux concurring with increase in the frequency of micronuclei accrued upon inhibition of autophagy, and similar results were also obtained in the rasfonin-treated cells. Moreover, the punctate LC3 staining colocalized with micronuclei. Unexpectedly, deprivation of SQSTM1/p62 alone accumulated micronuclei, which was not further increased upon challenge with ST. Rad51 is a protein central to repairing DSB by homologous recombination and treatment with ST or rasfonin decreased its expression. In several cell lines, p62 appeared in the immunoprecipites of Rad51, whereas LC3, Ulk1 and p62 interacted with PARP-1, another protein involved in DNA repair and genomic stability. In addition, knockdown of either Rad51 or PARP-1 completely inhibited the ST-induced autophagic flux. Taken together, the data presented here demonstrated that both LC3-II and the phosphorylated Ulk1 localized in nuclei and interacted with the proteins essential for nuclear stability, thereby revealing a more intimate relationship between autophagy and genomic stability. PMID:28796254

  8. Corrosion Sensor for Monitoring the Service Condition of Chloride-Contaminated Cement Mortar

    PubMed Central

    Lu, Shuang; Ba, Heng-Jing

    2010-01-01

    A corrosion sensor for monitoring the corrosion state of cover mortar was developed. The sensor was tested in cement mortar, with and without the addition of chloride to simulate the adverse effects of chloride-contaminated environmental conditions on concrete structures. In brief, a linear polarization resistance method combined with an embeddable reference electrode was utilized to measure the polarization resistance (Rp) using built-in sensor electrodes. Subsequently, electrochemical impedance spectroscopy in the frequency range of 1 kHz to 50 kHz was used to obtain the cement mortar resistance (Rs). The results show that the polarization resistance is related to the chloride content and Rs; ln (Rp) is linearly related to the Rs values in mortar without added chloride. The relationships observed between the Rp of the steel anodes and the resistance of the surrounding cement mortar measured by the corrosion sensor confirms that Rs can indicate the corrosion state of concrete structures. PMID:22319347

  9. [Simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using solid phase extraction-reversed-phase high performance liquid chromatography].

    PubMed

    Zhang, Hua; Yang, Xin; Ma, Ying; Dong, Aijun; Zhang, Yingchun

    2008-05-01

    A method was developed for the simultaneous determination of canthaxanthin and astaxanthin in feedstuffs using reversed-phase high performance liquid chromatography (RP-HPLC). The sample was extracted by acetonitrile, and cleaned up by an LC-NH2 column. An Agilent ZORBAX Eclipse XDB-C18 analytical column (150 mm x 4.6 mm, 5 microm) was used and kept at 25 degrees C. Acetonitrile-methanol (95 : 5, v/v) was used as the mobile phase at a flow rate of 1.0 mL/min. The detection was performed by a diode array detector at 474 nm. The quantitive analysis of external standard calibration curves was used. The linear ranges of the method for canthaxanthin and astaxanthin were 1.0 - 30.0 mg/L (r = 0.999 0) and 1.0 - 20.0 mg/L (r = 0.999 1), respectively. The average recoveries were 90% - 101% with the relative standard deviations of 0.62% - 3.68%. The detection limits were 0.84 and 0.60 mg/L for canthaxanthin and astaxanthin, respectively. The method is simple, precise, sensitive and reproductive. It can be used to determine the contents of canthaxanthin and astaxanthin in feedstuffs.

  10. Determination of adulteration of malachite green in green pea and some prepared foodstuffs by micellar liquid chromatography.

    PubMed

    Ashok, Vipin; Agrawal, Nitasha; Durgbanshi, Abhilasha; Esteve-Romero, Josep; Bose, Devasish

    2014-01-01

    A simple, fast, and robust micellar LC method was developed for the separation and identification of the nonpermitted color malachite green in green pea and some ready-to-eat foodstuffs. Malachite green (4-[(4-dimethylaminophenyl) phenyl-methyl]-N,N-dimethylaniline) is a hazardous dye that is used to treat fungal and protozoan infections in fish and is a common adulterant (coloring agent) in green pea and other green vegetables because of its green color. In the present work, malachite green was determined in various foodstuffs using a direct injection technique on an RP C18 column with isocratic elution. The optimum mobile phase consisted of 0.15 M sodium dodecyl sulfate (SDS), 6% pentanol buffered at pH 5. Detection was carried out at 620 nm. Malachite green was eluted in 9.2 min without any interference caused by endogenous compounds. Linearities (r > 0.9999), intraday and interday precision (RSD less than 1.00%) in micellar media, and robustness were studied for method validation. LOD and LOQ were 0.10 and 0.25 ppm, respectively. The simplicity of the developed method makes it useful for routine analysis in the area of food QC.

  11. Isolation of a small molecule with anti-MRSA activity from a mangrove symbiont Streptomyces sp. PVRK-1 and its biomedical studies in Zebrafish embryos.

    PubMed

    Kannan, Rajaretinam Rajesh; Iniyan, Appadurai Muthamil; Prakash, Vincent Samuel Gnana

    2011-10-01

    The aim of the present study was to isolate the anti-MRSA (Methicillin Resistant Staphylococcus aureus) molecule from the Mangrove symbiont Streptomyces and its biomedical studies in Zebrafish embryos. MRSA was isolated from the pus samples of Colachal hospitals and confirmed by amplification of mecA gene. Anti-MRSA molecule producing strain was identified by 16s rRNA gene sequencing. Anti-MRSA compound production was optimized by Solid State Fermentation (SSF) and the purification of the active molecule was carried out by TLC and RP-HPLC. The inhibitory concentration and LC50 were calculated using Statistical software SPSS. The Biomedical studies including the cardiac assay and organ toxicity assessment were carried out in Zebrafish. The bioactive anti-MRSA small molecule A2 was purified by TLC with Rf value of 0.37 with 1.389 retention time at RP-HPLC. The Inhibitory Concentration of the purified molecule A2 was 30 µg/mL but, the inhibitory concentration of the MRSA in the infected embryo was 32-34 µg/mL for TLC purified molecule A2 with LC50 mean value was 61.504 µg/mL. Zebrafish toxicity was assessed in 48-60 µg/mL by observing the physiological deformities and the heart beat rates (HBR) of embryos for anti MRSA molecule showed the mean of 41.33-41.67 HBR/15 seconds for 40 µg/mL and control was 42.33-42.67 for 15 seconds which significantly showed that the anti-MRSA molecule A2 did not affected the HBR. Anti-MRSA molecule from Streptomyces sp PVRK-1 was isolated and biomedical studies in Zebrafish model assessed that the molecule was non toxic at the minimal inhibitory concentration of MRSA.

  12. Online solid phase extraction liquid chromatography tandem mass spectrometry (SPE-LC-MS/MS) method for the determination of sucralose in reclaimed and drinking waters and its photo degradation in natural waters from South Florida

    PubMed Central

    2013-01-01

    Background Sucralose has gained popularity as a low calorie artificial sweetener worldwide. Due to its high stability and persistence, sucralose has shown widespread occurrence in environmental waters, at concentrations that could reach up to several μg/L. Previous studies have used time consuming sample preparation methods (offline solid phase extraction/derivatization) or methods with rather high detection limits (direct injection) for sucralose analysis. This study described a faster and sensitive analytical method for the determination of sucralose in environmental samples. Results An online SPE-LC–MS/MS method was developed, being capable to quantify sucralose in 12 minutes using only 10 mL of sample, with method detection limits (MDLs) of 4.5 ng/L, 8.5 ng/L and 45 ng/L for deionized water, drinking and reclaimed waters (1:10 diluted with deionized water), respectively. Sucralose was detected in 82% of the reclaimed water samples at concentrations reaching up to 18 μg/L. The monthly average for a period of one year was 9.1 ± 2.9 μg/L. The calculated mass loads per capita of sucralose discharged through WWTP effluents based on the concentrations detected in wastewaters in the U. S. is 5.0 mg/day/person. As expected, the concentrations observed in drinking water were much lower but still relevant reaching as high as 465 ng/L. In order to evaluate the stability of sucralose, photodegradation experiments were performed in natural waters. Significant photodegradation of sucralose was observed only in freshwater at 254 nm. Minimal degradation (<20%) was observed for all matrices under more natural conditions (350 nm or solar simulator). The only photolysis product of sucralose identified by high resolution mass spectrometry was a de-chlorinated molecule at m/z 362.0535, with molecular formula C12H20Cl2O8. Conclusions Online SPE LC-APCI/MS/MS developed in the study was applied to more than 100 environmental samples. Sucralose was frequently detected (>80%) indicating that the conventional treatment process employed in the sewage treatment plants is not efficient for its removal. Detection of sucralose in drinking waters suggests potential contamination of surface and ground waters sources with anthropogenic wastewater streams. Its high resistance to photodegradation, minimal sorption and high solubility indicate that sucralose could be a good tracer of anthropogenic wastewater intrusion into the environment. PMID:23965251

  13. A Novel LC-MS-MS Method With an Effective Antioxidant for the Determination of Edaravone, a Free-Radical Scavenger in Dog Plasma and its Application to a Pharmacokinetic Study.

    PubMed

    Shao, Feng; Hu, Xiao-Ling; Liu, Xin; Shan, Mang-Ting

    2017-07-01

    The objective of this study was to investigate the stability of edaravone in dog plasma by using an added antioxidant stabilizer, with an ultimate goal of developing and validating a sensitive, reliable and robust LC-MS-MS method for determination of edaravone in plasma samples. Edaravone was unstable in plasma, but it presented a good stability performance in the plasma with sodium metabisulfite (SMB), an effective antioxidant. The blood sample was collected in the heparinized eppendorf tube containing SMB and plasma sample was deproteinized using acetonitrile containing 20 ng/mL of phenacetin (Internal standard). The chromatographic separation was performed on a Zorbax Extend-C18 analytical column (2.1 mm × 150 mm I.D., particle size 3.5 µm, Agilent Technologies, USA). The mobile phase consisted of 0.1% formic acid in water (v/v) and methanol, and gradient elution was used. The analyte detection was performed on a triple quadrupole tandem mass spectrometer equipped with positive-ion electrospray ionization by multiple reaction ion monitoring mode of the transitions at m/z [M + H]+ 175.1 → 77.1 for edaravone, and m/z [M + H]+ 180.2 → 110.0 for phenacetin. The linearity of this method was within the concentration range of 10-1000 ng/mL for edaravone in dog plasma. The lower limit of quantification was 10 ng/mL. The relative standard deviations of intra- and inter-precision were <10%. This method was successfully employed in the pharmacokinetics evaluation of edaravone in beagle dogs after intravenous administration. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. [Analysis on microdialysis probe recovery of baicalin in vitro and in vivo based on LC-MS/MS].

    PubMed

    Chen, Teng-Fei; Liu, Jian-Xun; Zhang, Ying; Lin, Li; Song, Wen-Ting; Yao, Ming-Jiang

    2017-06-01

    To further study the brain behavior and the pharmacokinetics of baicalin in intercellular fluid of brain, and study the recovery rate and stability of brain and blood microdialysis probe of baicalin in vitro and in vivo. The concentration of baicalin in brain and blood microdialysates was determined by LC-MS/MS and the probe recovery for baicalin was calculated. The effects of different flow rates (0.50, 1.0, 1.5, 2.0,3.0 μL•min⁻¹) on recovery in vitro were determined by incremental method and decrement method. The effects of different drug concentrations (50.00, 200.0, 500.0, 1 000 μg•L⁻¹) and using times (0, 1, 2) on recovery in vitro were determined by incremental method. The probe recovery stability and effect of flow rate on recovery in vivo were determined by decrement method, and its results were compared with those in in vitro trial. The in vitro recovery of brain and blood probe of baicalin was decreased with the increase of flow rate under the same concentration; and at the same flow rate, different concentrations of baicalin had little influence on the recovery. The probe which had been used for 2 times showed no obvious change in probe recovery by syringe with 2% heparin sodium and ultrapure water successively. In vitro recovery rates obtained by incremental method and decrement method were approximately equal under the same condition, and the in vivo recovery determined by decrement method was similar with the in vitro results and they were showed a good stability within 10 h. The results showed that decrement method can be used for pharmacokinetic study of baicalin, and can be used to study probe recovery in vivo at the same time. Copyright© by the Chinese Pharmaceutical Association.

  15. Simultaneous LC-MS/MS determination of phenylbutyrate, phenylacetate benzoate and their corresponding metabolites phenylacetylglutamine and hippurate in blood and urine.

    PubMed

    Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan

    2010-12-01

    Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.

  16. Identifying initiation and elongation inhibitors of dengue virus RNA polymerase in a high-throughput lead-finding campaign.

    PubMed

    Smith, Thomas M; Lim, Siew Pheng; Yue, Kimberley; Busby, Scott A; Arora, Rishi; Seh, Cheah Chen; Wright, S Kirk; Nutiu, Razvan; Niyomrattanakit, Pornwaratt; Wan, Kah Fei; Beer, David; Shi, Pei-Yong; Benson, Timothy E

    2015-01-01

    Dengue virus (DENV) is the most significant mosquito-borne viral pathogen in the world and is the cause of dengue fever. The DENV RNA-dependent RNA polymerase (RdRp) is conserved among the four viral serotypes and is an attractive target for antiviral drug development. During initiation of viral RNA synthesis, the polymerase switches from a "closed" to "open" conformation to accommodate the viral RNA template. Inhibitors that lock the "closed" or block the "open" conformation would prevent viral RNA synthesis. Herein, we describe a screening campaign that employed two biochemical assays to identify inhibitors of RdRp initiation and elongation. Using a DENV subgenomic RNA template that promotes RdRp de novo initiation, the first assay measures cytosine nucleotide analogue (Atto-CTP) incorporation. Liberated Atto fluorophore allows for quantification of RdRp activity via fluorescence. The second assay uses the same RNA template but is label free and directly detects RdRp-mediated liberation of pyrophosphates of native ribonucleotides via liquid chromatography-mass spectrometry. The ability of inhibitors to bind and stabilize a "closed" conformation of the DENV RdRp was further assessed in a differential scanning fluorimetry assay. Last, active compounds were evaluated in a renilla luciferase-based DENV replicon cell-based assay to monitor cellular efficacy. All assays described herein are medium to high throughput, are robust and reproducible, and allow identification of inhibitors of the open and closed forms of DENV RNA polymerase. © 2014 Society for Laboratory Automation and Screening.

  17. Gradient polymer network liquid crystal with a large refractive index change.

    PubMed

    Ren, Hongwen; Xu, Su; Wu, Shin-Tson

    2012-11-19

    A simple approach for preparing gradient polymer network liquid crystal (PNLC) with a large refractive index change is demonstrated. To control the effective refractive index at a given cell position, we applied a voltage to a homogeneous cell containing LC/diacrylate monomer mixture to generate the desired tilt angle and then stabilize the LC orientation with UV-induced polymer network. By varying the applied voltage along with the cells' movement, a PNLC with a gradient refractive index distribution is obtained. In comparison with conventional approaches using patterned photomask or electrode, our method offers following advantages: large refractive index change, freedom to design specific index profile, and large panel capability. Potential applications include tunable-focus lenses, prism gratings, phase modulators, and other adaptive photonic devices.

  18. RP-HPLC method development and validation for simultaneous estimation of atorvastatin calcium and pioglitazone hydrochloride in pharmaceutical dosage form.

    PubMed

    Peraman, Ramalingam; Mallikarjuna, Sasikala; Ammineni, Pravalika; Kondreddy, Vinod kumar

    2014-10-01

    A simple, selective, rapid, precise and economical reversed-phase high-performance liquid chromatographic (RP-HPLC) method has been developed for simultaneous estimation of atorvastatin calcium (ATV) and pioglitazone hydrochloride (PIO) from pharmaceutical formulation. The method is carried out on a C8 (25 cm × 4.6 mm i.d., 5 μm) column with a mobile phase consisting of acetonitrile (ACN):water (pH adjusted to 6.2 using o-phosphoric acid) in the ratio of 45:55 (v/v). The retention time of ATV and PIO is 4.1 and 8.1 min, respectively, with the flow rate of 1 mL/min with diode array detector detection at 232 nm. The linear regression analysis data from the linearity plot showed good linear relationship with a correlation coefficient (R(2)) value for ATV and PIO of 0.9998 and 0.9997 in the concentration range of 10-80 µg mL(-1), respectively. The relative standard deviation for intraday precision has been found to be <2.0%. The method is validated according to the ICH guidelines. The developed method is validated in terms of specificity, selectivity, accuracy, precision, linearity, limit of detection, limit of quantitation and solution stability. The proposed method can be used for simultaneous estimation of these drugs in marketed dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Application of LC-MS analysis to the characterisation of the in vitro and in vivo metabolite profiles of RGH-1756 in the rat.

    PubMed

    Gémesi, L I; Kapás, M; Szeberényi, S

    2001-03-01

    RGH-1756, 1-(2-methoxy-phenyl)-4-(4-[4-(6-imidazol[2,1-b] thiazolyl)-phenoxy]-butyl-4-(14)C)-piperazine dimethane is a novel atypical antipsychotic drug candidate of Gedeon Richter Ltd. The metabolic pathways of the compound have been investigated by profiling the metabolites present in plasma, bile, and faeces samples of rats treated with (14)C-RGH-1756. The metabolites formed in vitro by rat liver microsomes have also been analysed. Good separation of the compounds has been achieved by gradient HPLC method on Zorbax/Bonus RP-C18 column. Radiometry and mass spectrometry have been applied to detect and characterise the metabolites. The metabolite formed by oxidative cleavage of the chain at the carbon atom adjacent to the piperazine nitrogen has been identified as the major plasma metabolite. Glucuronide conjugate of hydroxy-RGH-1756 has been found as one of the main metabolites excreted in the bile where the unchanged compound has not been detected.

  20. CRF19_cpx is an Evolutionary fit HIV-1 Variant Strongly Associated With Rapid Progression to AIDS in Cuba

    PubMed Central

    Kouri, Vivian; Khouri, Ricardo; Alemán‬, Yoan; Abrahantes, Yeissel; Vercauteren, Jurgen; Pineda-Peña, Andrea-Clemencia; Theys, Kristof; Megens, Sarah; Moutschen, Michel; Pfeifer, Nico; Van Weyenbergh, Johan; Pérez, Ana B.; Pérez, Jorge; Pérez, Lissette; Van Laethem, Kristel; Vandamme, Anne-Mieke

    2015-01-01

    Background Clinicians reported an increasing trend of rapid progression (RP) (AIDS within 3 years of infection) in Cuba. Methods Recently infected patients were prospectively sampled, 52 RP at AIDS diagnosis (AIDS-RP) and 21 without AIDS in the same time frame (non-AIDS). 22 patients were sampled at AIDS diagnosis (chronic-AIDS) retrospectively assessed as > 3 years infected. Clinical, demographic, virological, epidemiological and immunological data were collected. Pol and env sequences were used for subtyping, transmission cluster analysis, and prediction of resistance, co-receptor use and evolutionary fitness. Host, immunological and viral predictors of RP were explored through data mining. Findings Subtyping revealed 26 subtype B strains, 6 C, 6 CRF18_cpx, 9 CRF19_cpx, 29 BG-recombinants and other subtypes/URFs. All patients infected with CRF19 belonged to the AIDS-RP group. Data mining identified CRF19, oral candidiasis and RANTES levels as the strongest predictors of AIDS-RP. CRF19 was more frequently predicted to use the CXCR4 co-receptor, had higher fitness scores in the protease region, and patients had higher viral load at diagnosis. Interpretation CRF19 is a recombinant of subtype D (C-part of Gag, PR, RT and nef), subtype A (N-part of Gag, Integrase, Env) and subtype G (Vif, Vpr, Vpu and C-part of Env). Since subtypes D and A have been associated with respectively faster and slower disease progression, our findings might indicate a fit PR driving high viral load, which in combination with co-infections may boost RANTES levels and thus CXCR4 use, potentially explaining the fast progression. We propose that CRF19 is evolutionary very fit and causing rapid progression to AIDS in many newly infected patients in Cuba. PMID:26137563

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roach, Mack, E-mail: mroach@radonc.ucsf.edu; Ceron Lizarraga, Tania L.; Lazar, Ann A.

    Purpose: The optimal treatment of clinically localized prostate cancer is controversial. Most studies focus on biochemical (PSA) failure when comparing radical prostatectomy (RP) with radiation therapy (RT), but this endpoint has not been validated as predictive of overall survival (OS) or cause-specific survival (CSS). We analyzed the available literature to determine whether reliable conclusions could be made concerning the effectiveness of RP compared with RT with or without androgen deprivation therapy (ADT), assuming current treatment standards. Methods: Articles published between February 29, 2004, and March 1, 2015, that compared OS and CSS after RP or RT with or without ADTmore » were included. Because the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) system emphasis is on randomized controlled clinical trials, a reliability score (RS) was explored to further understand the issues associated with the study quality of observational studies, including appropriateness of treatment, source of data, clinical characteristics, and comorbidity. Lower RS values indicated lower reliability. Results: Fourteen studies were identified, and 13 were completely evaluable. Thirteen of the 14 studies (93%) were observational studies with low-quality evidence. The median RS was 12 (range, 5-18); the median difference in 10-year OS and CSS favored RP over RT: 10% and 4%, respectively. In studies with a RS ≤12 (average RS 9) the 10-year OS and CSS median differences were 17% and 6%, respectively. For studies with a RS >12 (average RS 15.5), the 10-year OS and CSS median differences were 5.5% and 1%, respectively. Thus, we observed an association between low RS and a higher percentage difference in OS and CSS. Conclusions: Reliable evidence that RP provides a superior CSS to RT with ADT is lacking. The most reliable studies suggest that the differences in 10-year CSS between RP and RT are small, possibly <1%.« less

  2. Polyphosphazene toughened high performance thermosets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abu-Shanab, O.L.; Duygulu, M.; Soucek, M.D.

    1995-12-31

    Two modified polyphosphazenes were synthesized and characterized via FT-IR, {sup 1}H and {sup 31}P NMR, and DSC. Semi-Interpenetrating networks based on phenyl imide substituted polyphosphazene and polyimide thermoset resin designated LaRC{trademark} RP46 were prepared. Grafted copolymers were formed by grafting the backbone of maleimide substituted polyphosphazene into LaRC{trademark} RP46 thermoset resin. Thin films with a 0 to 40 Wt% range of polyphosphazene to polyimide ratio were prepared. A structure-property relationships of these inorganic/organic polymeric matrices were studied and evaluated in terms of fracture toughness, thermo-oxidative stability, thermal, and tensile properties.

  3. Determination of illegal adulteration of dietary supplements with synthetic hair-growth compounds by UPLC and LC-Q-TOF/MS.

    PubMed

    Lee, Ji Hyun; Kang, Gihaeng; Park, Han Na; Kim, Jihee; Kim, Nam Sook; Park, Seongsoo; Park, Sung-Kwan; Baek, Sun Young; Kang, Hoil

    2018-02-01

    In this study, we developed a UPLC-PDA and LC-Q-TOF/MS method to identify and measure the following prohibited substances that may be found in dietary supplements:triaminodil, minoxidil, bimatoprost, alimemazine, diphenylcyclopropenone, α-tradiol, finasteride, methyltestosterone, spironolatone, flutamide, cyproterone, dutasteride, and testosterone 17-propionate.The method was validated according to International Conference on Harmonization guidelines in terms of specificity, linearity, accuracy, precision, LOD, LOQ, recovery, and stability. The method was completely validated showing satisfactory data for all method validation parameters. The linearity was good (R 2  > 0.999) with intra- and inter-day precision values of 0.2-3.4% and 0.3-2.9%, respectively. Moreover, the intra- and inter-day accuracies were 87-102% and 86-103%, respectively, and the precision was better than 9.4% (relative standard deviation).Hence, the proposed method is precise and has high quality,and can be utilised to comprehensively and continually monitor illegal drug adulteration in various forms of dietary supplements. Furthermore, to evaluate the applicability of the proposed method, we analysed 13 hair-growth compounds in 78 samples including food and dietary supplements. Minoxidil and triaminodil were detected in capsules at concentrations of 4.69 mg/g and 6.54 mg/g. In addition, finasteride was detected in a tablet at 13.45 mg/g. In addition, the major characteristic fragment ions were confirmed once again using LC-Q-TOF/MS for higher accuracy.

  4. The application of electrochemistry to pharmaceutical stability testing--comparison with in silico prediction and chemical forced degradation approaches.

    PubMed

    Torres, Susana; Brown, Roland; Szucs, Roman; Hawkins, Joel M; Zelesky, Todd; Scrivens, Garry; Pettman, Alan; Taylor, Mark R

    2015-11-10

    The aim of this study was to evaluate the use of electrochemistry to generate oxidative degradation products of a model pharmaceutical compound. The compound was oxidized at different potentials using an electrochemical flow-cell fitted with a glassy carbon working electrode, a Pd/H2 reference electrode and a titanium auxiliary electrode. The oxidative products formed were identified and structurally characterized by LC-ESI-MS/MS using a high resolution Q-TOF mass spectrometer. Results from electrochemical oxidation using electrolytes of different pH were compared to those from chemical oxidation and from accelerated stability studies. Additionally, oxidative degradation products predicted using an in silico commercially available software were compared to those obtained from the various experimental methods. The electrochemical approach proved to be useful as an oxidative stress test as all of the final oxidation products observed under accelerated stability studies could be generated; previously reported reactive intermediate species were not observed most likely because the electrochemical mechanism differs from the oxidative pathway followed under accelerated stability conditions. In comparison to chemical degradation tests electrochemical degradation has the advantage of being much faster and does not require the use of strong oxidizing agents. Moreover, it enables the study of different operating parameters in short periods of time and optimisation of the reaction conditions (pH and applied potential) to achieve different oxidative products mixtures. This technique may prove useful as a stress test condition for the generation of oxidative degradation products and may help accelerate structure elucidation and development of stability indicating analytical methods. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Swirl Coaxial Injector Testing with LOX/RP-J

    NASA Technical Reports Server (NTRS)

    Greene, Sandra Elam; Casiano, Matt

    2013-01-01

    Testing was conducted at NASA fs Marshall Space Flight Center (MSFC) in the fall of 2012 to evaluate the operation and performance of liquid oxygen (LOX) and kerosene (RP ]1) in an existing swirl coaxial injector. While selected Russian engines use variations of swirl coaxial injectors, component level performance data has not been readily available, and all previously documented component testing at MSFC with LOX/RP ]1 had been performed using a variety of impinging injector designs. Impinging injectors have been adequate for specific LOX/RP ]1 engine applications, yet swirl coaxial injectors offer easier fabrication efforts, providing cost and schedule savings for hardware development. Swirl coaxial elements also offer more flexibility for design changes. Furthermore, testing with LOX and liquid methane propellants at MSFC showed that a swirl coaxial injector offered improved performance compared to an impinging injector. So, technical interest was generated to see if similar performance gains could be achieved with LOX/RP ]1 using a swirl coaxial injector. Results would allow such injectors to be considered for future engine concepts that require LOX/RP ]1 propellants. Existing injector and chamber hardware was used in the test assemblies. The injector had been tested in previous programs at MSFC using LOX/methane and LOX/hydrogen propellants. Minor modifications were made to the injector to accommodate the required LOX/RP ]1 flows. Mainstage tests were performed over a range of chamber pressures and mixture ratios. Additional testing included detonated gbombs h for stability data. Test results suggested characteristic velocity, C*, efficiencies for the injector were 95 ]97%. The injector also appeared dynamically stable with quick recovery from the pressure perturbations generated in the bomb tests.

  6. Surface treatment influences electrochemical stability of cpTi exposed to mouthwashes.

    PubMed

    Beline, Thamara; Garcia, Camila S; Ogawa, Erika S; Marques, Isabella S V; Matos, Adaias O; Sukotjo, Cortino; Mathew, Mathew T; Mesquita, Marcelo F; Consani, Rafael X; Barão, Valentim A R

    2016-02-01

    The role of surface treatment on the electrochemical behavior of commercially pure titanium (cpTi) exposed to mouthwashes was tested. Seventy-five disks were divided into 15 groups according to surface treatment (machined, sand blasted with Al2O3, and acid etched) and electrolyte solution (artificial saliva — control, 0.12% chlorhexidine digluconate, 0.05% cetylpyridinium chloride, 0.2% sodium fluoride, and 1.5% hydrogen peroxide) (n = 5). Open-circuit-potential and electrochemical impedance spectroscopy were conducted at baseline and after 7 and 14 days of immersion in each solution. Potentiodynamic test and total weight loss of disks were performed after 14 days of immersion. Scanning electron microscopy, energy dispersive spectroscopy, white light interferometry and profilometry were conducted for surface characterization before and after the electrochemical tests. Sandblasting promoted the lowest polarization resistance (Rp) (P b .0001) and the highest capacitance (CPE) (P b .006), corrosion current density (Icorr) and corrosion rate (P b .0001). In contrast, acid etching increased Rp and reduced CPE, independent to the mouthwash; while hydrogen peroxide reduced Rp (P b .008) and increased Icorr and corrosion rate (P b .0001). The highest CPE values were found for hydrogen peroxide and 0.2% sodium fluoride. Immersion for longer period improved the electrochemical stability of cpTi (P b .05). In conclusion, acid etching enhanced the electrochemical stability of cpTi. Hydrogen peroxide and sodium fluoride reduced the resistance to corrosion of cpTi, independent to the surface treatment. Chlorhexidine gluconate and cetylpyridinium chloride did not alter the corrosive behavior of cpTi.

  7. Lipidomic analysis of glycerolipid and cholesteryl ester autooxidation products.

    PubMed

    Kuksis, Arnis; Suomela, Jukka-Pekka; Tarvainen, Marko; Kallio, Heikki

    2009-06-01

    Thin-layer chromatography (TLC), gas chromatography (GC), and liquid chromatography (LC) in combination with mass spectrometry (MS) have been adopted for the isolation and identification of oxolipids and for determining their functionality. TLC provides a rapid separation and access to most oxolipids as intact molecules and has recently been effectively interfaced with time-of-flight (TOF) MS (TOF-MS). GC with flame ionization (FI) (GC/FI) and electron impact (EI) MS (GC/EI-MS) has been extensively utilized in the analysis of isoprostanes and other low-molecular-weight oxolipids, although these methods require derivatization of the analytes. In contrast, LC with ultraviolet (UV) absorption (LC/UV) or evaporate light scattering detection (ELSD) (LC/ELSD) as well as electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) MS (LC/ESI-MS) or LC/APCI-MS has proven to be well suited for the analysis of intact oxolipids and their conjugates without or with minimal derivatization. Nevertheless, kit-based colorimetric and fluorescent procedures continue to serve as sensitive indicators of the presence of hydroperoxides and aldehydes.

  8. Simultaneous extraction of propofol and propofol glucuronide from hair followed by validated LC-MS/MS analyses.

    PubMed

    Maas, Alexandra; Maier, Christoph; Iwersen-Bergmann, Stefanie; Madea, Burkhard; Hess, Cornelius

    2017-11-30

    Besides its clinical application, the anaesthetic agent propofol is being increasingly misused, mostly by healthcare professionals, and its abuse potential gained worldwide attention after the tragic death of Michael Jackson in 2009. Due to the short duration of its narcotic effects, propofol abuse is especially easy to hide compared with the use of other recreational drugs. However, propofol possesses a very narrow therapeutic window between the desired effect and potentially fatal toxicity, making abuse of the drug extremely dangerous even in experienced physicians. Consequently, it is important that forensic laboratories possess a sensitive and specific method for the detection of chronic propofol abuse. We present a simple, fast and reliable method to simultaneously extract propofol and its main metabolite propofol glucuronide from hair, followed by sensitive LC-MS/MS analyses, allowing to determine a chronic propofol abuse. Difficulties regarding the detection of propofol using LC-MS/MS were solved by using a derivatization reaction with 2-fluoro-1-methylpyridinium-p-toluene-sulfonate and triethylamine. Reliability of extraction method and subsequent LC-MS/MS analyses was confirmed under consideration of the validation parameters selectivity, linearity, accuracy and precision, analytical limits, processed sample stability, matrix effects and recovery. Appropriate quantification (LLOQ=10pg/mg hair) and detection limits (3.6pg/mg hair for propofol and 7.8 pg/mg hair for propofol glucuronide) could be achieved, enabling to detect even small amounts of both analytes. Applicability of the method was confirmed by analysis of three human hair samples from deceased with suspicion of chronic propofol abuse. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. A robust, sensitive assay for genomic uracil determination by LC/MS/MS reveals lower levels than previously reported.

    PubMed

    Galashevskaya, Anastasia; Sarno, Antonio; Vågbø, Cathrine B; Aas, Per A; Hagen, Lars; Slupphaug, Geir; Krokan, Hans E

    2013-09-01

    Considerable progress has been made in understanding the origins of genomic uracil and its role in genome stability and host defense; however, the main question concerning the basal level of uracil in DNA remains disputed. Results from assays designed to quantify genomic uracil vary by almost three orders of magnitude. To address the issues leading to this inconsistency, we explored possible shortcomings with existing methods and developed a sensitive LC/MS/MS-based method for the absolute quantification of genomic 2'-deoxyuridine (dUrd). To this end, DNA was enzymatically hydrolyzed to 2'-deoxyribonucleosides and dUrd was purified in a preparative HPLC step and analyzed by LC/MS/MS. The standard curve was linear over four orders of magnitude with a quantification limit of 5 fmol dUrd. Control samples demonstrated high inter-experimental accuracy (94.3%) and precision (CV 9.7%). An alternative method that employed UNG2 to excise uracil from DNA for LC/MS/MS analysis gave similar results, but the intra-assay variability was significantly greater. We quantified genomic dUrd in Ung(+/+) and Ung(-/-) mouse embryonic fibroblasts and human lymphoblastoid cell lines carrying UNG mutations. DNA-dUrd is 5-fold higher in Ung(-/-) than in Ung(+/+) fibroblasts and 11-fold higher in UNG2 dysfunctional than in UNG2 functional lymphoblastoid cells. We report approximately 400-600 dUrd per human or murine genome in repair-proficient cells, which is lower than results using other methods and suggests that genomic uracil levels may have previously been overestimated. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  10. A review of rapid prototyping (RP) techniques in the medical and biomedical sector.

    PubMed

    Webb, P A

    2000-01-01

    The evolution of rapid prototyping (RP) technology is briefly discussed, and the application of RP technologies to the medical sector is reviewed. Although the use of RP technology has been slow arriving in the medical arena, the potential of the technique is seen to be widespread. Various uses of the technology within surgical planning, prosthesis development and bioengineering are discussed. Some possible drawbacks are noted in some applications, owing to the poor resolution of CT slice data in comparison with that available on RP machines, but overall, the methods are seen to be beneficial in all areas, with one early report suggesting large improvements in measurement and diagnostic accuracy as a result of using RP models.

  11. A Non-Biological Method for Screening Active Components against Influenza Virus from Traditional Chinese Medicine by Coupling a LC Column with Oseltamivir Molecularly Imprinted Polymers

    PubMed Central

    Yang, Ya-Jun; Li, Jian-Yong; Liu, Xi-Wang; Zhang, Ji-Yu; Liu, Yu-Rong; Li, Bing

    2013-01-01

    To develop a non-biological method for screening active components against influenza virus from traditional Chinese medicine (TCM) extraction, a liquid chromatography (LC) column prepared with oseltamivir molecularly imprinted polymer (OSMIP) was employed with LC-mass spectrometry (LC-MS). From chloroform extracts of compound TCM liquid preparation, we observed an affinitive component m/z 249, which was identified to be matrine following analysis of phytochemical literatures, OSMIP-LC column on-line of control compounds and MS/MS off-line. The results showed that matrine had similar bioactivities with OS against avian influenza virus H9N2 in vitro for both alleviating cytopathic effect and hemagglutination inhibition and that the stereostructures of these two compounds are similar while their two-dimensional structures were different. In addition, our results suggested that the bioactivities of those affinitive compounds were correlated with their chromatographic behaviors, in which less difference of the chromatographic behaviors might have more similar bioactivities. This indicates that matrine is a potential candidate drug to prevent or cure influenza for human or animal. In conclusion, the present study showed that molecularly imprinted polymers can be used as a non-biological method for screening active components against influenza virus from TCM. PMID:24386385

  12. Mutation analysis of Leber congenital amaurosis‑associated genes in patients with retinitis pigmentosa.

    PubMed

    Shen, Tao; Guan, Liping; Li, Shiqiang; Zhang, Jianguo; Xiao, Xueshan; Jiang, Hui; Yang, Jianhua; Guo, Xiangming; Wang, Jun; Zhang, Qingjiong

    2015-03-01

    The genetic defects underlying approximately half of all retinitis pigmentosa (RP) cases are unknown. A number of genes responsible for Leber congenital amaurosis (LCA) may also cause RP when they are mutated. Our previous study revealed that variants in the most frequently mutated nine exons accounted for approximately half of the mutations detected in a cohort of patients with LCA. The aim of the present study was to detect mutations in LCA-associated genes in patients with RP using two different strategies. Sanger sequencing was used to screen mutations in the nine exons in 293 patients with RP and exome sequencing was used to detect variants in 12 LCA-associated genes in 157 of the 293 patients with RP and then to validate the variants by Sanger sequencing. Potential pathogenic mutations were identified in four patients with early onset RP, including homozygous CRB1 mutations in two patients, compound heterozygous CRB1 mutations in one patient and compound heterozygous CEP290 mutations in one patient. The present study indicated that mutations in CEP290 may also be associated with RP but not with LCA. With the exception of CEP290, the remaining 11 genes known to be associated with LCA but not with RP are unlikely to be a common cause of RP.

  13. Polar and nonpolar organic polymer-based monolithic columns for capillary electrochromatography and high-performance liquid chromatography.

    PubMed

    Rathnasekara, Renuka; Khadka, Shantipriya; Jonnada, Murthy; El Rassi, Ziad

    2017-01-01

    This review article is a continuation of the previous reviews on the area of monolithic columns covering the progress made in the field over the last couple of years from the beginning of the second half of 2014 until the end of the first half of 2016. It summarizes and evaluates the evolvement of both polar and nonpolar organic monolithic columns and their use in hydrophilic interaction LC and CEC and reversed-phase chromatography and RP-CEC. The review article discusses the results reported in a total of 62 references. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  15. Highlight removal based on the regional-projection fringe projection method

    NASA Astrophysics Data System (ADS)

    Qi, Zhaoshuai; Wang, Zhao; Huang, Junhui; Xing, Chao; Gao, Jianmin

    2018-04-01

    In fringe projection profilometry, highlight usually causes the saturation and blooming in captured fringes and reduces the measurement accuracy. To solve the problem, a regional-projection fringe projection (RP-FP) method is proposed. Regional projection patterns (RP patterns) are projected onto the tested object surface to avoid the saturation and blooming. Then, an image inpainting technique is employed to reconstruct the missing phases in the captured RP patterns and a complete surface of the tested object is obtained. Experiments verified the effectiveness of the proposed method. The method can be widely used in industrial inspections and quality controlling in mechanical and manufacturing industries.

  16. Characterization of the thermolysis products of Nafion membrane: A potential source of perfluorinated compounds in the environment

    NASA Astrophysics Data System (ADS)

    Feng, Mingbao; Qu, Ruijuan; Wei, Zhongbo; Wang, Liansheng; Sun, Ping; Wang, Zunyao

    2015-05-01

    The thermal decomposition of Nafion N117 membrane, a typical perfluorosulfonic acid membrane that is widely used in various chemical technologies, was investigated in this study. Structural identification of thermolysis products in water and methanol was performed using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS). The fluoride release was studied using an ion-chromatography system, and the membrane thermal stability was characterized by thermogravimetric analysis. Notably, several types of perfluorinated compounds (PFCs) including perfluorocarboxylic acids were detected and identified. Based on these data, a thermolysis mechanism was proposed involving cleavage of both the polymer backbone and its side chains by attack of radical species. This is the first systematic report on the thermolysis products of Nafion by simulating its high-temperature operation and disposal process via incineration. The results of this study indicate that Nafion is a potential environmental source of PFCs, which have attracted growing interest and concern in recent years. Additionally, this study provides an analytical justification of the LC/ESI-MS/MS method for characterizing the degradation products of polymer electrolyte membranes. These identifications can substantially facilitate an understanding of their decomposition mechanisms and offer insight into the proper utilization and effective management on these membranes.

  17. 75 FR 8188 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ...-9, and RP 2008-52, RP 2009-XX; Changes in Methods of Accounting. Description: The information... taxpayer properly is requesting to change its method of accounting and the terms and conditions of the... approved collection. Title: REG-141402-02 Limitation on Use of the Nonaccrual-Experience Method of...

  18. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  19. Analysis of bovine milk caseins on organic monolithic columns: an integrated capillary liquid chromatography-high resolution mass spectrometry approach for the study of time-dependent casein degradation.

    PubMed

    Pierri, Giuseppe; Kotoni, Dorina; Simone, Patrizia; Villani, Claudio; Pepe, Giacomo; Campiglia, Pietro; Dugo, Paola; Gasparrini, Francesco

    2013-10-25

    Casein proteins constitute approximately 80% of the proteins present in bovine milk and account for many of its nutritional and technological properties. The analysis of the casein fraction in commercially available pasteurized milk and the study of its time-dependent degradation is of considerable interest in the agro-food industry. Here we present new analytical methods for the study of caseins in fresh and expired bovine milk, based on the use of lab-made capillary organic monolithic columns. An integrated capillary high performance liquid chromatography and high-resolution mass spectrometry (Cap-LC-HRMS) approach was developed, exploiting the excellent resolution, permeability and biocompatibility of organic monoliths, which is easily adaptable to the analysis of intact proteins. The resolution obtained on the lab-made Protein-Cap-RP-Lauryl-γ-Monolithic column (270 mm × 0.250 mm length × internal diameter, L × I.D.) in the analysis of commercial standard caseins (αS-CN, β-CN and κ-CN) through Cap-HPLC-UV was compared to the one observe using two packed capillary C4 columns, the ACE C4 (3 μm, 150 mm × 0.300 mm, L × I.D.) and the Jupiter C4 column (5 μm, 150 mm × 0.300 mm, L × I.D.). Thanks to the higher resolution observed, the monolithic capillary column was chosen for the successive degradation studies of casein fractions extracted from bovine milk 1-4 weeks after expiry date. The comparison of the UV chromatographic profiles of skim, semi-skim and whole milk showed a major stability of whole milk towards time-dependent degradation of caseins, which was further sustained by high-resolution analysis on a 50-cm long monolithic column using a 120-min time gradient. Contemporarily, the exact monoisotopic and average molecular masses of intact αS-CN and β-CN protein standards were obtained through high resolution mass spectrometry and used for casein identification in Cap-LC-HRMS analysis. Finally, the proteolytic degradation of β-CN in skim milk and the contemporary formation of low-molecular-weight proteose-peptones (PP) with exact monoisotopic Mr between 9444.0989 Da and 14098.9861 Da was confirmed through the deconvolution of high resolution mass spectra and literature data. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Clinical and Rehabilitative Management of Retinitis Pigmentosa: Up-to-Date

    PubMed Central

    Parmeggiani, Francesco; Sato, Giovanni; De Nadai, Katia; Romano, Mario R; Binotto, Andrea; Costagliola, Ciro

    2011-01-01

    The term retinitis pigmentosa (RP) indicates a heterogeneous group of genetic rare ocular diseases in which either rods or cones are prevalently damaged. RP represents the most common hereditary cause of blindness in people from 20 to 60 years old. In general, the different RP forms consist of progressive photo-receptorial neuro-degenerations, which are characterized by variable visual disabilities and considerable socio-sanitary burden. Sometimes, RP patients do not become visually impaired or legally blind until their 40-50 years of age and/or maintain a quite acceptable sight for all their life. Other individuals with RP become completely blind very early or in middle childhood. Although there is no treatment that can effectively cure RP, in some case-series the disease’s progression seems to be reducible by specific preventive approaches. In the most part of RP patients, the quality of vision can be considerably increased by means of nanometer-controlled filters. In the present review, the main aspects of the routine clinical and rehabilitative managements for RP patients are described, particularly focusing on the importance of specific referral Centers to practice a real multidisciplinary governance of these dramatic diseases. PMID:22131870

  1. Automated on-line SPE LC-MS/MS method to quantitate 6beta-hydroxycortisol and cortisol in human urine: use of the 6beta-hydroxycortisol to cortisol ratio as an indicator of CYP3A4 activity.

    PubMed

    Barrett, Yu Chen; Akinsanya, Billy; Chang, Shu-Ying; Vesterqvist, Ole

    2005-07-25

    A sensitive method for quantitation of urinary 6beta-hydroxycortisol (6beta-HC) and cortisol using on-line SPE and LC-MS/MS was developed and validated. Human urine samples were injected directly onto an on-line solid phase extraction apparatus, Prospekt-2, followed by HPLC separation and electrospray triple quadrupole LC-MS/MS detection. The inter-day precision for the 6beta-HC:cortisol ratio was 7-9%. The lower limit of quantitation was 1 and 0.2 ng/mL for 6beta-HC and cortisol, respectively. Using the method we observed a diurnal variation on the 6beta-HC:cortisol ratio in healthy volunteers with the maximal ratio observed in the 2-10 pm urine collection period.

  2. Quantification of residual EDU (N-ethyl-N'-(dimethylaminopropyl) carbodiimide (EDC) hydrolyzed urea derivative) and other residual by LC-MS/MS.

    PubMed

    Lei, Q Paula; Lamb, David H; Shannon, Anthony G; Cai, Xinxing; Heller, Ronald K; Huang, Michael; Zablackis, Earl; Ryall, Robert; Cash, Patricia

    2004-12-25

    An LC-MS/MS method for determination of the break down product of N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide (EDC) urea derivative, EDU, has been developed and validated for monitoring the residual coupling reagents. Results indicate that the method exhibits suitable specificity, sensitivity, precision, linearity and accuracy for quantification of residual EDU in the presence of meningococcal polysaccharide-diphtheria toxoid conjugate vaccine and other vaccine matrix compounds. The assay has been validated for a detection range of 10-100 ng/mL and then successfully transferred to quality control (QC) lab. This same method has also been applied to the determination of residual diaminohexane (DAH) in the presence of EDU. LC-MS/MS has proven to be useful as a quick and sensitive approach for simultaneous determination of multiple residual compounds in glycoconjugate vaccine samples.

  3. Liquid crystal materials and tunable devices for optical communications

    NASA Astrophysics Data System (ADS)

    Du, Fang

    In this dissertation, liquid crystal materials and devices are investigated in meeting the challenges for photonics and communications applications. The first part deals with polymer-stabilized liquid crystal (PSLC) materials and devices. Three polymer-stabilized liquid crystal systems are developed for optical communications. The second part reports the experimental investigation of a novel liquid-crystal-infiltrated photonic crystal fiber (PCF) and explores its applications in fiber-optic communications. The curing temperature is found to have significant effects on the PSLC performance. The electro-optic properties of nematic polymer network liquid crystal (PNLC) at different curing temperatures are investigated experimentally. At high curing temperature, a high contrast, low drive voltage, and small hysteresis PNLC is obtained as a result of the formed large LC microdomains. With the help of curing temperature effect, it is able to develop PNLC based optical devices with highly desirable performances for optical communications. Such high performance is generally considered difficult to realize for a PNLC. In fact, the poor performance of PNLC, especially at long wavelengths, has hindered it from practical applications for optical communications for a long time. Therefore, the optimal curing temperature effect discovered in this thesis would enable PSLCs for practical industrial applications. Further more, high birefringence LCs play an important role for near infrared photonic devices. The isothiocyanato tolane liquid crystals exhibit a high birefringence and low viscosity. The high birefringence LC dramatically improves the PSLC contrast ratio while keeping a low drive voltage and fast response time. A free-space optical device by PNLC is experimentally demonstrated and its properties characterized. Most LC devices are polarization sensitive. To overcome this drawback, we have investigated the polymer-stabilized cholesteric LC (PSCLC). Combining the curing temperature effect and high birefringence LC, a polarization independent fiber-optical device is realized with over 30 dB attenuation, ˜12 V rms drive voltage and 11/28 milliseconds (rise/decay) response times. A polymer-stabilized twisted nematic LC (PS TNLC) is also proposed as a variable optical attenuator for optical communications. By using the polarization control system, the device is polarization independent. The polymer network in a PS TNLC not only results in a fast response time (0.9/9 milliseconds for rise/decay respectively), but also removes the backflow effect of TNLC which occurs in the high voltage regime. Another major achievement in this thesis is the first demonstration of an electrically tunable LC-infiltrated photonic crystal fiber (PCF). Two different LC PCF configurations are studied. For the first time, electrically tunable LC PCFs are demonstrated experimentally. The guiding mechanism and polarization properties are studied. Preliminary experimental results are also given for the thermo-optical properties of a LC filled air-core PCF. In conclusion, this dissertation has solved important issues related to PSLC and enables its applications as VOAs and light shutters in optical communications. Through experimental investigations of the LC filled PCFs, a new possibility of developing tunable micro-sized fiber devices is opened for optical communications as well.

  4. Expansion of the Scope of AOAC First Action Method 2012.25--Single-Laboratory Validation of Triphenylmethane Dye and Leuco Metabolite Analysis in Shrimp, Tilapia, Catfish, and Salmon by LC-MS/MS.

    PubMed

    Andersen, Wendy C; Casey, Christine R; Schneider, Marilyn J; Turnipseed, Sherri B

    2015-01-01

    Prior to conducting a collaborative study of AOAC First Action 2012.25 LC-MS/MS analytical method for the determination of residues of three triphenylmethane dyes (malachite green, crystal violet, and brilliant green) and their metabolites (leucomalachite green and leucocrystal violet) in seafood, a single-laboratory validation of method 2012.25 was performed to expand the scope of the method to other seafood matrixes including salmon, catfish, tilapia, and shrimp. The validation included the analysis of fortified and incurred residues over multiple weeks to assess analyte stability in matrix at -80°C, a comparison of calibration methods over the range 0.25 to 4 μg/kg, study of matrix effects for analyte quantification, and qualitative identification of targeted analytes. Method accuracy ranged from 88 to 112% with 13% RSD or less for samples fortified at 0.5, 1.0, and 2.0 μg/kg. Analyte identification and determination limits were determined by procedures recommended both by the U. S. Food and Drug Administration and the European Commission. Method detection limits and decision limits ranged from 0.05 to 0.24 μg/kg and 0.08 to 0.54 μg/kg, respectively. AOAC First Action Method 2012.25 with an extracted matrix calibration curve and internal standard correction is suitable for the determination of triphenylmethane dyes and leuco metabolites in salmon, catfish, tilapia, and shrimp by LC-MS/MS at a residue determination level of 0.5 μg/kg or below.

  5. Optimization of ultra-high pressure liquid chromatography - tandem mass spectrometry determination in plasma and red blood cells of four sphingolipids and their evaluation as biomarker candidates of Gaucher's disease.

    PubMed

    Chipeaux, Caroline; de Person, Marine; Burguet, Nathalie; Billette de Villemeur, Thierry; Rose, Christian; Belmatoug, Nadia; Héron, Sylvie; Le Van Kim, Caroline; Franco, Mélanie; Moussa, Fathi

    2017-11-24

    While important advances have been recently achieved in the optimization of lipid classes' separation, information on the specific determination of medium polarity lipids such as sphingolipids (SLs) in highly complex matrices remains fragmentary. In human, disorders of SL metabolism known as sphingolipidoses are a heterogeneous group of inherited disorders affecting primarily the central nervous. Early diagnosis of these conditions is of importance notably when a corrective therapy is available. The diagnosis is generally based on the determination of specific SLs in plasma and red blood cells (RBCs). For instance, glucosylceramide (GL1), glucosylsphingosine (Lyso-GL1), sphingosine (Sph), and sphingosine-1-phosphate (S1P) are proposed as relevant biomarkers for Gaucher disease (GD). Our main objective was to evaluate these biomarker candidates in a cohort of GD patients. However, most of current methods of GL1, Lyso-GL1, Sph, and S1P determination in plasma of GD patients require at least two liquid chromatographic runs. On the other hand, except for GL1 nothing is known concerning the RBC sphingolipid content. Yet, several reversed phase LC-MS methods of SLs separation and/or determination in various media with different sample preparation approaches have been proposed since 2010. Here we focused on stationary phase selection and mobile phase composition as well as on the sample preparation step to optimize and validate an UHPLC-MS/MS method for the simultaneous quantification of the four sphingolipids in both plasma and RBCs. A comparison between seven stationary phases including two RP18, two polar embedded RP18, and three HILIC phases shows that under our conditions polar embedded RP18 phases are the most appropriate for the separation of the four SLs, in terms of efficiency, peak symmetry, and separation time. In the same way, a comparison between a single step extraction with methanol and a liquid-liquid extraction with a mixture of methanol/methyl tert-butyl ether, shows that the latter mixture is the most appropriate for the extraction of SLs in terms of recovery and absence of matrix effect. After validation, this method was applied to the evaluation of the targeted SLs in a cohort of 15 known GD patients. The obtained results show that Lyso-GL1 is the only relevant biomarker in both plasma and RBCs for GD diagnosis. As the proposed method is applicable to the determination in such a highly complex matrices of four SLs with a large difference in polarity, and as the sample preparation procedure is freedom of matrix effects, this method can be easily adapted to a large diversity of samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. The replicative DNA polymerase of herpes simplex virus 1 exhibits apurinic/apyrimidinic and 5′-deoxyribose phosphate lyase activities

    PubMed Central

    Bogani, Federica; Boehmer, Paul E.

    2008-01-01

    Base excision repair (BER) is essential for maintaining genome stability both to counter the accumulation of unusual bases and to protect from base loss in the DNA. Herpes simplex virus 1 (HSV-1) is a large dsDNA virus that encodes its own DNA replication machinery, including enzymes involved in nucleotide metabolism. We report on a replicative family B and a herpesvirus-encoded DNA Pol that possesses DNA lyase activity. We have discovered that the catalytic subunit of the HSV-1 DNA polymerase (Pol) (UL30) exhibits apurinic/apyrimidinic (AP) and 5′-deoxyribose phosphate (dRP) lyase activities. These activities are integral to BER and lead to DNA cleavage on the 3′ side of abasic sites and 5′-dRP residues that remain after cleavage by 5′-AP endonuclease. The UL30-catalyzed reaction occurs independently of divalent cation and proceeds via a Schiff base intermediate, indicating that it occurs via a lyase mechanism. Partial proteolysis of the Schiff base shows that the DNA lyase activity resides in the Pol domain of UL30. These observations together with the presence of a virus-encoded uracil DNA glycosylase indicates that HSV-1 has the capacity to perform critical steps in BER. These findings have implications on the role of BER in viral genome maintenance during lytic replication and reactivation from latency. PMID:18695225

  7. Round robin test on quantification of amyloid-β 1-42 in cerebrospinal fluid by mass spectrometry.

    PubMed

    Pannee, Josef; Gobom, Johan; Shaw, Leslie M; Korecka, Magdalena; Chambers, Erin E; Lame, Mary; Jenkins, Rand; Mylott, William; Carrillo, Maria C; Zegers, Ingrid; Zetterberg, Henrik; Blennow, Kaj; Portelius, Erik

    2016-01-01

    Cerebrospinal fluid (CSF) amyloid-β 1-42 (Aβ42) is an important biomarker for Alzheimer's disease, both in diagnostics and to monitor disease-modifying therapies. However, there is a great need for standardization of methods used for quantification. To overcome problems associated with immunoassays, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has emerged as a critical orthogonal alternative. We compared results for CSF Aβ42 quantification in a round robin study performed in four laboratories using similar sample preparation methods and LC-MS instrumentation. The LC-MS results showed excellent correlation between laboratories (r(2) >0.98), high analytical precision, and good correlation with enzyme-linked immunosorbent assay (r(2) >0.85). The use of a common reference sample further decreased interlaboratory variation. Our results indicate that LC-MS is suitable for absolute quantification of Aβ42 in CSF and highlight the importance of developing a certified reference material. Copyright © 2016 The Alzheimer's Association. Published by Elsevier Inc. All rights reserved.

  8. Prolactin-releasing peptide affects gastric motor function in rat by modulating synaptic transmission in the dorsal vagal complex.

    PubMed

    Grabauskas, Gintautas; Zhou, Shi-Yi; Das, Sudipto; Lu, Yuanxu; Owyang, Chung; Moises, Hylan C

    2004-12-15

    Prolactin-releasing peptide (PrRP) is a recently discovered neuropeptide implicated in the central control of feeding behaviour and autonomic homeostasis. PrRP-containing neurones and PrRP receptor mRNA are found in abundance in the caudal portion of the nucleus tractus solitarius (NTS), an area which together with the dorsal motor nucleus of the vagus (DMV) comprises an integrated structure, the dorsal vagal complex (DVC) that processes visceral afferent signals from and provides parasympathetic motor innervation to the gastrointestinal tract. In this study, microinjection experiments were conducted in vivo in combination with whole-cell recording from neurones in rat medullary slices to test the hypothesis that PrRP plays a role in the central control of gastric motor function, acting within the DVC to modulate the activity of preganglionic vagal motor neurones that supply the stomach. Microinjection of PrRP (0.2 pmol (20 nl)(-1)) into the DMV at the level of the area postrema (+0.2 to +0.6 mm from the calamus scriptorius, CS) markedly stimulated gastric contractions and increased intragastric pressure (IGP). Conversely, administration of peptide into the DMV at sites caudal to the obex (0.0 to -0.3 mm from the CS) decreased IGP and reduced phasic contractions. These effects occurred without change in mean arterial pressure and were abolished by ipsilateral vagotomy, indicating mediation via a vagal-dependent mechanism(s). The pattern of gastric motor responses evoked by PrRP mimicked that produced by administration of L-glutamate at the same sites, and both the effects of L-glutamate and PrRP were abolished following local administration of NMDA and non-NMDA-type glutamate receptor antagonists. On the other hand, microinjection of PrRP into the medial or comissural nucleus of the solitary tract (mNTS and comNTS, respectively) resulted in less robust changes in IGP in a smaller percentage of animals, accompanied by marked alterations in arterial pressure. Superfusion of brain slices with PrRP (100-300 nm) produced a small depolarization and increased spontaneous firing in 10 of 30 retrogradely labelled gastric-projecting DMV neurones. The excitatory effects were blocked by administration of TTX (2 mum) or specific glutamate receptor antagonists, indicating that they resulted from interactions of PrRP at a presynaptic site. Congruent with this, PrRP increased the amplitude of excitatory postsynaptic currents (EPSCs, 154 +/- 33%, 12 of 25 neurones) evoked by electrical stimulation in mNTS or comNTS. In addition, administration of PrRP decreased the paired-pulse ratio of EPSCs evoked by two identical stimuli delivered 100 ms apart (from 0.95 +/- 0.08 to 0.71 +/- 0.11, P < 0.05), whereas it did not affect the amplitude of inward currents evoked by exogenous application of L-glutamate to the slice. The frequency, but not amplitude of spontaneous EPSCs and action potential-independent miniature EPSCs was also increased by administration of PrRP, suggesting that the peptide was acting at least in part at receptors on presynaptic nerve terminals to enhance glutamatergic transmission. In recordings obtained from a separate group of slices, we did not observe any direct effects of PrRP on spontaneous discharge or postsynaptic excitability in either mNTS or comNTS neurones (n = 31). These data indicate that PrRP may act within the DVC to regulate gastric motor function by modulating the efficacy of conventional excitatory synaptic inputs from the NTS onto gastric-projecting vagal motor neurones.

  9. Prolactin-releasing peptide affects gastric motor function in rat by modulating synaptic transmission in the dorsal vagal complex

    PubMed Central

    Grabauskas, Gintautas; Zhou, Shi-Yi; Das, Sudipto; Lu, Yuanxu; Owyang, Chung; Moises, Hylan C

    2004-01-01

    Prolactin-releasing peptide (PrRP) is a recently discovered neuropeptide implicated in the central control of feeding behaviour and autonomic homeostasis. PrRP-containing neurones and PrRP receptor mRNA are found in abundance in the caudal portion of the nucleus tractus solitarius (NTS), an area which together with the dorsal motor nucleus of the vagus (DMV) comprises an integrated structure, the dorsal vagal complex (DVC) that processes visceral afferent signals from and provides parasympathetic motor innervation to the gastrointestinal tract. In this study, microinjection experiments were conducted in vivo in combination with whole-cell recording from neurones in rat medullary slices to test the hypothesis that PrRP plays a role in the central control of gastric motor function, acting within the DVC to modulate the activity of preganglionic vagal motor neurones that supply the stomach. Microinjection of PrRP (0.2 pmol (20 nl)−1) into the DMV at the level of the area postrema (+0.2 to +0.6 mm from the calamus scriptorius, CS) markedly stimulated gastric contractions and increased intragastric pressure (IGP). Conversely, administration of peptide into the DMV at sites caudal to the obex (0.0 to −0.3 mm from the CS) decreased IGP and reduced phasic contractions. These effects occurred without change in mean arterial pressure and were abolished by ipsilateral vagotomy, indicating mediation via a vagal-dependent mechanism(s). The pattern of gastric motor responses evoked by PrRP mimicked that produced by administration of l-glutamate at the same sites, and both the effects of l-glutamate and PrRP were abolished following local administration of NMDA and non-NMDA-type glutamate receptor antagonists. On the other hand, microinjection of PrRP into the medial or comissural nucleus of the solitary tract (mNTS and comNTS, respectively) resulted in less robust changes in IGP in a smaller percentage of animals, accompanied by marked alterations in arterial pressure. Superfusion of brain slices with PrRP (100–300 nm) produced a small depolarization and increased spontaneous firing in 10 of 30 retrogradely labelled gastric-projecting DMV neurones. The excitatory effects were blocked by administration of TTX (2 μm) or specific glutamate receptor antagonists, indicating that they resulted from interactions of PrRP at a presynaptic site. Congruent with this, PrRP increased the amplitude of excitatory postsynaptic currents (EPSCs, 154 ± 33%, 12 of 25 neurones) evoked by electrical stimulation in mNTS or comNTS. In addition, administration of PrRP decreased the paired-pulse ratio of EPSCs evoked by two identical stimuli delivered 100 ms apart (from 0.95 ± 0.08 to 0.71 ± 0.11, P < 0.05), whereas it did not affect the amplitude of inward currents evoked by exogenous application of l-glutamate to the slice. The frequency, but not amplitude of spontaneous EPSCs and action potential-independent miniature EPSCs was also increased by administration of PrRP, suggesting that the peptide was acting at least in part at receptors on presynaptic nerve terminals to enhance glutamatergic transmission. In recordings obtained from a separate group of slices, we did not observe any direct effects of PrRP on spontaneous discharge or postsynaptic excitability in either mNTS or comNTS neurones (n = 31). These data indicate that PrRP may act within the DVC to regulate gastric motor function by modulating the efficacy of conventional excitatory synaptic inputs from the NTS onto gastric-projecting vagal motor neurones. PMID:15486017

  10. Label-free offline versus online activity methods for nucleoside diphosphate kinase b using high performance liquid chromatography.

    PubMed

    Lima, Juliana Maria; Salmazo Vieira, Plínio; Cavalcante de Oliveira, Arthur Henrique; Cardoso, Carmen Lúcia

    2016-08-07

    Nucleoside diphosphate kinase from Leishmania spp. (LmNDKb) has recently been described as a potential drug target to treat leishmaniasis disease. Therefore, screening of LmNDKb ligands requires methodologies that mimic the conditions under which LmNDKb acts in biological systems. Here, we compare two label-free methodologies that could help screen LmNDKb ligands and measure NDKb activity: an offline LC-UV assay for soluble LmNDKb and an online two-dimensional LC-UV system based on LmNDKb immobilised on a silica capillary. The target enzyme was immobilised on the silica capillary via Schiff base formation (to give LmNDKb-ICER-Schiff) or affinity attachment (to give LmNDKb-ICER-His). Several aspects of the ICERs resulting from these procedures were compared, namely kinetic parameters, stability, and procedure steps. Both the LmNDKb immobilisation routes minimised the conformational changes and preserved the substrate binding sites. However, considering the number of steps involved in the immobilisation procedure, the cost of reagents, and the stability of the immobilised enzyme, immobilisation via Schiff base formation proved to be the optimal procedure.

  11. Determination of drug residues in urine of dogs receiving anti-cancer chemotherapy by liquid chromatography-electrospray ionization- tandem mass spectrometry: is there an environmental or occupational risk?

    PubMed

    Hamscher, Gerd; Mohring, Siegrun A I; Knobloch, Anna; Eberle, Nina; Nau, Heinz; Nolte, Ingo; Simon, Daniela

    2010-04-01

    Cytotoxic drugs, previously used only in human medicine, are increasingly utilized for cancer treatment in veterinary practice. We developed and validated a liquid chromatography (LC)-electrospray ionization-tandem mass spectrometry (MS-MS) method to determine vincristine, vinblastine, cyclophosphamide, and doxorubicin in canine urine. Sample pretreatment consisted of liquid-liquid extraction, and LC separation was carried out on an RP C(18) column employing a 0.5% formic acid/methanol gradient system. The analytes were detected in positive ion mode using the MS-MS scan mode. The mean recoveries in six different urine samples were between 64.2% and 86.9%. Limits of quantitation were 0.5 microg/L for vincristine and vinblastine, 1 microg/L for cyclophosphamide, and 5 microg/L for doxorubicin; limits of detection were approximately 0.25 microg/L for vincristine, vinblastine, and cyclophosphamide and 0.5 microg/L for doxorubicin. It could be demonstrated that all investigated drugs are found in urine of dogs undergoing chemotherapy. In samples from day 1 after chemotherapy, as much as 63 microg/L vincristine, 111 microg/L vinblastine, and 762 microg/L doxorubicin could be detected. Cyclophosphamide showed only minor concentrations on day 1, but up to 2583 microg/L could be found directly after chemotherapy. These initial data show that there might be a potential contamination risk when administering cytotoxics in veterinary medicine.

  12. N2O emissions in tropical rainforest and rubber plantation, the indicator from landuse changing in Xishuangbanna, Southwest China

    NASA Astrophysics Data System (ADS)

    Zhou, W. J.; Zhu, J.; Ji, H. L.; Zhang, Y.; Zhang, J.; Zheng, X.

    2016-12-01

    To understand the effects of landuse on N2O emissions and local climate change in the tropics, we measured N2O fluxes from a primary tropical rainforest (TRF, with treatments of litter removal and control) and a fertilized rubber plantation (RP, with treatments of fertilization (75 kg N ha-1 yr-1) and unfertilization) at Xishuangbanna, southwest China since 2012. The results have shown: 1) Fertilized RP N2O emission is bimodel, one peak after dry season fertilizer, another after rainy season fertilizer. Otherwise, the unfertilized RP and TRF have the similar seasonal dynamic with one peak in the middle of rainy season. 2) due to the fertilizer influence, the poaitive correlation between soil temperature/soil moisture and N2O was more significantly in unfertilized RP than fertilized RP respectively litter input changed the dominated controller of N2O emission in TRF: litter carbon input and soil DOC content for control treatment and, soil temperature and soil NO3- -N for litter removal treatment. 3) lab incubation indicated denitrification and nitrification as the main source for N2O emission in TRF and RP, respectively. 4) The N2O emissions from the fertilized and unfertilized plots in RP were 4.0 and 2.5 kg N ha-1 yr-1, respectively, from control and litter removal plots in TRF were 0.48 and 0.32 kg N ha-1 yr-1,respectively. 5) 100-year carbon dioxide equivalence of N2O from fertilized RP offsets 5.8% and 31.5% of carbon sink of the rubber plantation and local TRF, respectively. Upscaling it to the whole Xishuangbanna, N2O emissions from fertilized RP offset 17.1% of the tropical rainforest's carbon sink. When tropical rainforests are converted to fertilized rubber plantations, the N2O emission seasonal dynamic and mechanisms changed, the global warming effect is enhanced.

  13. N2O emissions in tropical rainforest and rubber plantation, the indicator from landuse changing in Xishuangbanna, Southwest China

    NASA Astrophysics Data System (ADS)

    Zhou, Wenjun; Zhu, Jing; Ji, Hong-li; Zhang, Yi-Ping; Sha, Li-Qing; Gao, Jin-Bo; Zhang, Jun-Hui; Zheng, Xunhua

    2017-04-01

    To understand the effects of landuse on N2O emissions and local climate change in the tropics, we measured N2O fluxes from a primary tropical rainforest (TRF, with treatments of litter removal and control) and a fertilized rubber plantation (RP, with treatments of fertilization (75 kg N ha-1 yr-1) and unfertilization) at Xishuangbanna, southwest China since 2012. The results have shown: 1) Fertilized RP N2O emission is bimodel, one peak after dry season fertilizer, another after rainy season fertilizer. Otherwise, the unfertilized RP and TRF have the similar seasonal dynamic with one peak in the middle of rainy season. 2) due to the fertilizer influence, the poaitive correlation between soil temperature/soil moisture and N2O was more significantly in unfertilized RP than fertilized RP respectively litter input changed the dominated controller of N2O emission in TRF: litter carbon input and soil DOC content for control treatment and, soil temperature and soil NO3- -N for litter removal treatment. 3) lab incubation indicated denitrification and nitrification as the main source for N2O emission in TRF and RP, respectively. 4) The N2O emissions from the fertilized and unfertilized plots in RP were 4.0 and 2.5 kg N ha-1 yr-1, respectively, from control and litter removal plots in TRF were 0.48 and 0.32 kg N ha-1 yr-1,respectively. 5) 100-year carbon dioxide equivalence of N2O from fertilized RP offsets 5.8% and 31.5% of carbon sink of the rubber plantation and local TRF, respectively. Upscaling it to the whole Xishuangbanna, N2O emissions from fertilized RP offset 17.1% of the tropical rainforest's carbon sink. When tropical rainforests are converted to fertilized rubber plantations, the N2O emission seasonal dynamic and mechanisms changed, the global warming effect is enhanced.

  14. Validation of a high performance liquid chromatography method for the stabilization of epigallocatechin gallate.

    PubMed

    Fangueiro, Joana F; Parra, Alexander; Silva, Amélia M; Egea, Maria A; Souto, Eliana B; Garcia, Maria L; Calpena, Ana C

    2014-11-20

    Epigallocatechin gallate (EGCG) is a green tea catechin with potential health benefits, such as anti-oxidant, anti-carcinogenic and anti-inflammatory effects. In general, EGCG is highly susceptible to degradation, therefore presenting stability problems. The present paper was focused on the study of EGCG stability in HEPES (N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid) medium regarding the pH dependency, storage temperature and in the presence of ascorbic acid a reducing agent. The evaluation of EGCG in HEPES buffer has demonstrated that this molecule is not able of maintaining its physicochemical properties and potential beneficial effects, since it is partially or completely degraded, depending on the EGCG concentration. The storage temperature of EGCG most suitable to maintain its structure was shown to be the lower values (4 or -20 °C). The pH 3.5 was able to provide greater stability than pH 7.4. However, the presence of a reducing agent (i.e., ascorbic acid) was shown to provide greater protection against degradation of EGCG. A validation method based on RP-HPLC with UV-vis detection was carried out for two media: water and a biocompatible physiological medium composed of Transcutol®P, ethanol and ascorbic acid. The quantification of EGCG for purposes, using pure EGCG, requires a validated HPLC method which could be possible to apply in pharmacokinetic and pharmacodynamics studies. Copyright © 2014. Published by Elsevier B.V.

  15. Multi-detection of preservatives in cheeses by liquid chromatography-tandem mass spectrometry.

    PubMed

    Fuselli, Fabio; Guarino, Chiara; La Mantia, Alessandro; Longo, Lucia; Faberi, Angelo; Marianella, Rosa Maria

    2012-10-01

    The incorrect use of preservatives in cheeses may compromise food safety and damage consumers. According to the law, more than one preservative may be contemporarily used in cheeses. So a method for their contemporary detection may be useful for both manufacturers and control agencies quality control. In this research a liquid chromatography-tandem mass spectrometric with electrospray ionization method for the multi-determination of seven preservatives (benzoic acid, citric acid, hexamethylenetetramine, lysozyme, natamycin, nisin and sorbic acid) in cheese was developed. The preservatives were contemporarily extracted from cheese by a single procedure, and analyzed by RP-LC/ESI-MS/MS (Ion Trap) in positive ionization mode, with single reaction monitoring (SRM) acquisition. Three sample types (hard, pasta filata and fresh cheese) were used for method evaluation. Recoveries were mostly higher than 90%; MDLs ranged from 0.02 to 0.26 mgkg(-1), and MQLs were included between 0.07 and 0.88 mgkg(-1). Due to matrix effect, quantitation was performed by referring to a matrix matched calibration curve, for each cheese typology. This method was also applied to commercial cheese samples, with good results. It appears fast, reliable and suitable for both screening and confirmation of the presence and quantitation of the preservatives in a single, multi-detection analysis. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Development and validation of method for TH588 and TH287, potent MTH1 inhibitors and new anti-cancer agents, for pharmacokinetic studies in mice plasma.

    PubMed

    Saleh, Aljona; Gökturk, Camilla; Warpman-Berglund, Ulrika; Helleday, Thomas; Granelli, Ingrid

    2015-02-01

    MTH1 is a protein that is required for cancer cell survival and is overexpressed in cancer cells. TH588 and TH287 are two new compounds that inhibit the MTH1 protein. The inhibitors were tested in pharmacokinetic studies on mice. A bioanalytical method was developed and validated for determination in mice plasma. The method was based on protein precipitation followed by LC-MS/MS analysis. The separation was performed on an Ascentis Express RP-Amide C18 column. The mass spectrometer was operated in positive electrospray ionization mode and the analytes were determined with multiple reaction monitoring (MRM). Abundant monoisotopic fragments were used for quantification. Two additional fragments were used for conformational analysis. The recovery of the compounds in plasma varied between 61 and 91% and the matrix effects were low and ranged between -3% and +2%. The method showed to be selective, linear, accurate and precise, and applicable for preclinical pharmacokinetic studies of TH588 and TH287 in mouse plasma. Half-life (T1/2) was ≤3.5h and maximum concentration (Cmax) ranged between 0.82 and 338μM for the different administration routes and compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Reconstructed Serine 288 in the Left Flipper Region of the Rat P2X7 Receptor Stabilizes Nonsensitized States.

    PubMed

    Ishchenko, Yevheniia; Novosolova, Nataliia; Khafizov, Kamil; Bart, Geneviève; Timonina, Arina; Fayuk, Dmitriy; Skorinkin, Andrei; Giniatullin, Rashid

    2017-07-05

    Serine 275, a conserved residue of the left flipper region of ATP-gated P2X3 receptors, plays a key role in both agonist binding and receptor desensitization. It is conserved in most of the P2X receptors except P2X7 and P2X6. By combining experimental patch-clamp and modeling approaches, we explored the role of the corresponding residue in the rat P2X7 receptor (rP2X7) by replacing the phenylalanine at position 288 with serine and characterizing the membrane currents generated by either the wild-type (WT) or the mutated rP2X7 receptor. F288S, an rP2X7 mutation, slowed the deactivation subsequent to 2 and 20 s applications of 1 mM ATP. F288S also prevented sensitization (a progressive current growth) observed with the WT in response to a 20 s application of 1 mM ATP. Increasing the ATP concentration to 5 mM promoted sensitization also in the mutated rP2X7 receptor, accelerating the deactivation rate to typical WT values. YO-PRO1 uptake in cells expressing either the WT or the F288S P2X7 receptor was consistent with recorded membrane current data. Interestingly, in the human P2X7 (hP2X7) receptor, substitution Y288S did not change the deactivation rate, while the Y288F mutant generated a "rat-like" phenotype with a fast deactivation rate. Our combined experimental, kinetic, and molecular modeling data suggest that the rat F288S novel phenotype is due to a slower rate of ATP binding and/or unbinding and stabilization of nonsensitized receptor states.

  18. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    PubMed Central

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  19. Selective detection of thiosulfate-containing peptides using tandem mass spectrometry.

    PubMed

    Raftery, Mark J

    2005-01-01

    Incubation of proteins or peptides containing disulfide bonds (S-S) with sodium sulfite (Na(2)SO(3)) cleaves S-S bonds producing approximately equimolar amounts of free thiols (-SH) and thiosulfates (-S-SO(3)H), a process known as sulfitolysis. Proteins and peptides containing thiosulfates were separated by reverse-phase high-performance liquid chromatography (RP-HPLC) and characterized by mass spectrometry (MS) and peptide mapping. The mass of the thiosulfate-containing peptide formed from oxidized insulin B chain was 3478.02 Da, 80 Da greater than the reduced peptide and corresponding precisely to addition of sulfur trioxide (SO(3)). Disulfide bond cleavage was also observed using RP-HPLC and MS after incubation of the intramolecular homodimer of mouse S100A8 (mass 20614 Da). The mass of HPLC-separated A8-SH was 10308 Da, and 10388 Da for A8-S-SO(3)H. Loss of SO(3) from multiply charged precursor ions was generally observed at elevated declustering potentials in the source region or within q(2) at relatively low collision energies (approximately 20 V). The characteristic loss of SO(3) at low collision energies preceded peptide backbone fragmentations at higher collision energies. Accurate mass measurement and charge-state discrimination, using a hybrid quadrupole time-of-flight mass spectrometer, allowed specific detection of thiosulfate-containing peptides. An information-dependent acquisition method, where the switch criterion was loss of m/z 79.9568, specifically identified 11 thiosulfate-containing peptides using nano-LC/MS from a tryptic digest of bovine serum albumin (BSA).

  20. Formulation of an RP-1 Pyrolysis Surrogate from Shock Tube Measurements of Fuel and Ethylene Time Histories

    DTIC Science & Technology

    2012-04-01

    They also provide modelers (in both kinetics and computational fluid dynamics) with a method of representing, during simulation, a fuel that may have...1 and RP-2 from [Huber 2009a] Composition, mole fraction Fluid RP-1 surrogate RP-2 surrogate -methyldecalin 0.354 0.354 5-methylnonane 0.150...modeling and experimental results. Experimental Thermal and Fluid Science, 28(7):701–708, 2004. L. F. Albright, B. L. Crynes, and W. H. Corcoran

Top