Treatment of Early Post-Op Wound Infection after Internal Fixation
2017-10-01
the fracture stable while the bone heals. Approximately 10%-40% of severe fractures fixed with internal fixation develop a deep wound infection during...effect of treatment of post-op wound infection in bones after fracture fixation or joint fusion and either: (Group 1) operative debridement and PO
Gbara, Ali; Heiland, Max; Schmelzle, Rainer; Blake, Felix
2008-04-01
Following open reduction, internal fixation of fractures of the mandible is predominantly achieved using plates and screws. Today, a multitude of osteosynthesis systems are available on the market. One therapy modality, primarily developed for orthopaedic surgery, is using angular stable osteosynthesis plate systems. The dominating principle of these is the bond between screw and plate following insertion. This principle of an "internal fixateur" results in a more stable fixation of the fragments associated with less compression of the bone surfaces. A new multidirectional osteosynthesis system (TiFix=Smartlock, Hamburg - Germany) was modified to fit the maxillofacial region and compared with four other well established osteosynthesis systems developed by Mondial, Medicon, Synthes, Leibinger-Stryker, one of these (Unilock by Synthes) being also angular stable. The resistance to deformation in varying directions was investigated following fixation in four different materials. The TiFix system proved more resistant to deformation even when mounted with fewer screws than the non-angular stable systems. This system results in greater stability even when fewer screws are used. For the clinician this means smaller access incisions, less soft tissue trauma, better aesthetic results, decreased duration of operation and a reduction of costs.
Operative Fixation Options for Elective and Diabetic Ankle Arthrodesis.
Ramanujam, Crystal L; Stapleton, John J; Zgonis, Thomas
2017-07-01
Ankle arthrodesis remains one of the most definitive treatment options for end-stage arthritis, paralysis, posttraumatic and postinfectious conditions, failed total ankle arthroplasty, and severe deformities. The general aims of ankle arthrodesis are to decrease pain and instability, correct the accompanying deformity, and create a stable plantigrade foot. Several surgical approaches have been reported for ankle arthrodesis with internal fixation options. External fixation has also evolved for ankle arthrodesis in certain clinical scenarios. This article provides a comprehensive analysis of midterm to long-term outcomes for ankle arthrodesis using internal and/or external fixation each for elective and diabetic conditions. Copyright © 2017 Elsevier Inc. All rights reserved.
Anderson, Richard C E; Ragel, Brian T; Mocco, J; Bohman, Leif-Erik; Brockmeyer, Douglas L
2007-07-01
Atlantoaxial and occipitocervical instability in children have traditionally been treated with posterior bone and wire fusion and external halo orthoses. Recently, successful outcomes have been achieved using rigid internal fixation, particularly C1-2 transarticular screws. The authors describe flow diagrams created to help clinicians determine which method of internal fixation to use in complex anatomical circumstances when bilateral transarticular screw placement is not possible. The records of children who underwent either atlantoaxial or occipitocervical fixation with rigid internal fixation over an 11-year period were retrospectively reviewed to define flow diagrams used to determine treatment protocols. Among the 95 patients identified who underwent atlantoaxial or occipitocervical fixation, the craniocervical anatomy in 25 patients (six atlantoaxial and 19 occipitocervical fixations [26%]) required alternative methods of internal fixation. Types of screw fixation included loop or rod constructs anchored by combinations of C1-2 transarticular screws (15 constructs), C-1 lateral mass screws (11), C-2 pars screws (24), C-2 translaminar screws (one), and subaxial lateral mass screws (six). The mean age of the patients (15 boys and 10 girls) was 9.8 years (range 1.3-17 years). All 22 patients with greater than 3-month follow-up duration achieved solid bone fusion and maintained stable constructs on radiographic studies. Clinical improvement was seen in all patients who had preoperative symptoms. Novel flow diagrams are suggested to help guide selection of rigid internal fixation constructs when performing pediatric C1-2 and occipitocervical stabilizations. Use of these flow diagrams has led to successful fusion in 25 pediatric patients with difficult anatomy requiring less common constructs.
[How to make your own custom cutting guides for both mandibular and fibular stair step osteotomies?
Rem, K; Bosc, R; De Kermadec, H; Hersant, B; Meningaud, J-P
2017-12-01
Using tailored cutting guides for osteocutaneous free fibula flap in complex mandibular reconstruction after cancer resection surgery constitutes a substantial improvement. Autonomously conceiving and manufacturing the cutting guides within a plastic surgery department with computer-aided design (CAD) and three-dimensional (3D) printing allows planning more complex osteotomies, such as stair-step osteotomies, in order to achieve more stable internal fixations. For the past three years, we have been producing by ourselves patient-tailored cutting guides using CAD and 3D printing. Osteotomies were virtually planned, making the cutting lines more complex in order to optimize the internal fixation stability. We also printed reconstructed mandible templates and shaped the reconstruction plates on them. We recorded data including manufacturing techniques and surgical outcomes. Eleven consecutive patients were operated on for an oral cavity cancer. For each patient, we planned the fibular and mandibular stair-step osteotomies and we produced tailored cutting guides. In all patients, we achieved to get immediately stable internal fixations and in 10 patients, a complete bone consolidation after 6 months. Autonomously manufacturing surgical cutting guides for mandibular reconstruction by free fibula flap is a significant improvement, regarding ergonomics and precision. Planning stair-step osteotomies to perform complementary internal fixation increases contact surface and congruence between the bone segments, thus improving the reconstructed mandible stability. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Jain, Mantu; Nanda, Saurav Narayan; Mohapatra, Soumya Shrikanta; Samal, Barada Prasanna
2017-08-01
Stabilization after a pelvic fracture can be accomplished using multiple techniques. The anterior external fixator has been traditionally used in variety of unstable pelvis either singly or in combination of posterior screws. These devices are cumbersome and restrict side turning and sitting particularly in obese patients. An alternative, anterior subcutaneous pelvic internal fixation technique (ASPIF) was developed which is well tolerated by patients for mobility and comfort and biomechanically more stable construct Complications of this construct included irritation of the lateral femoral cutaneous nerve, femoral nerve palsy &heterotypic ossification with reduced rates of infections and aseptic loosening as compared to external fixator. Bladder incarceration following treatment has never been reported and we encountered such a problem during management which we want to highlight.
Yeon, Yeung Kyu; Park, Hae Sang; Lee, Jung Min; Lee, Ji Seung; Lee, Young Jin; Sultan, Md Tipu; Seo, Ye Bin; Lee, Ok Joo; Kim, Soon Hee; Park, Chan Hum
Open reduction with internal fixation is commonly used for the treatment of bone fractures. However, postoperative infection associated with internal fixation devices (intramedullary nails, plates, and screws) remains a significant complication, and it is technically difficult to fix multiple fragmented bony fractures using internal fixation devices. In addition, drilling in the bone to install devices can lead to secondary fracture, bone necrosis associated with postoperative infection. In this study, we developed bone clip type internal fixation device using three- dimensional (3D) printing technology. Standard 3D model of the bone clip was generated based on computed tomography (CT) scan of the femur in the rat. Polylacticacid (PLA), hydroxyapatite (HA), and silk were used for bone clip material. The purpose of this study was to characterize 3D printed PLA, PLA/HA, and PLA/HA/Silk composite bone clip and evaluate the feasibility of these bone clips as an internal fixation device. Based on the results, PLA/HA/Silk composite bone clip showed similar mechanical property, and superior biocompatibility compared to other types of the bone clip. PLA/HA/Silk composite bone clip demonstrated excellent alignment of the bony segments across the femur fracture site with well-positioned bone clip in an animal study. Our 3D printed bone clips have several advantages: (1) relatively noninvasive (drilling in the bone is not necessary), (2) patient-specific design (3) mechanically stable device, and (4) it provides high biocompatibility. Therefore, we suggest that our 3D printed PLA/HA/Silk composite bone clip is a possible internal fixation device.
Sun, Yapeng; Zhang, Wei; Qie, Suhui; Zhang, Nan; Ding, Wenyuan; Shen, Yong
2017-07-01
The study was to comprehensively compare the postoperative outcome and imaging parameter characters in a short/middle period between the percutaneous endoscopic lumbar discectomy (PELD) and the internal fixation of bone graft fusion (the most common form is posterior lumbar interbody fusion [PLIF]) for the treatment of adjacent segment lumbar disc prolapse with stable retrolisthesis after a previous lumbar internal fixation surgery.In this retrospective case-control study, we collected the medical records from 11 patients who received PELD operation (defined as PELD group) for and from 13 patients who received the internal fixation of bone graft fusion of lumbar posterior vertebral lamina decompression (defined as control group) for the treatment of the lumbar disc prolapse combined with stable retrolisthesis at Department of Spine Surgery, the Third Hospital of Hebei Medical University (Shijiazhuang, China) from May 2010 to December 2015. The operation time, the bleeding volume of perioperation, and the rehabilitation days of postoperation were compared between 2 groups. Before and after surgery at different time points, ODI, VAS index, and imaging parameters (including Taillard index, inter-vertebral height, sagittal dislocation, and forward bending angle of lumbar vertebrae) were compared.The average operation time, the blooding volume, and the rehabilitation days of postoperation were significantly less in PELD than in control group. The ODI and VAS index in PELD group showed a significantly immediate improving on the same day after the surgery. However, Taillard index, intervertebral height, sagittal dislocation in control group showed an immediate improving after surgery, but no changes in PELD group till 12-month after surgery. The forward bending angle of lumbar vertebrae was significantly increased and decreased in PELD and in control group, respectively.PELD operation was superior in terms of operation time, bleeding volume, recovery period, and financial support, if compared with lumbar internal fixation operation. Radiographic parameters reflect lumber structure changes, which could be observed immediately after surgery in both methods; however, the recoveries on nerve function and pain relief required a longer time, especially after PLIF operation.
Mumtaz, Mohammad Umar; Farooq, Muneer Ahmad; Rasool, Altaf Ahmad; Kawoosa, Altaf Ahmad; Badoo, Abdul Rashid; Dhar, Shabir Ahmad
2010-07-01
Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can provide rigid fixation, allowing early mobilization of joints and hence good functional results while avoiding problems associated with protruding K-wires and immobilization. The advantages of such internal fixation urged us to undertake such a study in our state where such hand injuries are commonly seen. Forty patients with 42 unstable metacarpal and phalangeal fractures were treated with open reduction and internal fixation using AO mini-fragment screws and plates over a period of three years in a prospective manner. The overall results were good in 78.5% of cases, fair in 19% of cases and poor in 2.5% of cases, as judged according to the criteria of the American Society for Surgery of the Hand. This technique is a reasonable option for treating unstable metacarpal and phalangeal fractures as it provides a highly rigid fixation, which is sufficient to allow early mobilization of the adjacent joints, thus helping to achieve good functional results.
Cervical osteotomy in ankylosing spondylitis: evaluation of new developments.
Langeloo, Danielle D; Journee, Henricus L; Pavlov, Paul W; de Kleuver, Marinus
2006-04-01
Cervical osteotomy can be performed on patients with cervical kyphosis due to ankylosing spondylitis. This study reviews the role of two new developments in cervical osteotomy surgery: internal fixation and transcranial electrical stimulated motor evoked potential monitoring (TES-MEP). From 1999 to 2004, 16 patients underwent a C7-osteotomy with internal fixation. In 11 patients, cervical osteotomy was performed in a sitting position with halo-cast immobilization (group S), five patients underwent surgery in prone position with Mayfield clamp fixation (group P). In group P, longer fusion towards T4-T6 could be obtained that created a more stable fixation. Therefore, post-operative immobilization protocol of group P was simplified from halo-cast to cervical orthosis. Consolidation was obtained in all patients without loss of correction. Post-operative chin-brow to vertical angle measured 5 degrees (range 0-15). TES-MEP was successfully performed during all surgical procedures. In total, nine neurological events were registered. Additional surgical intervention resulted in recovery of amplitudes in six of nine events. In two patients spontaneous recovery took place. One patient showed no recovery of amplitudes despite surgical intervention and a partial C6 spinal cord lesion occurred. We conclude that C7 osteotomy with internal fixation has been shown to be a reliable and stable technique. When surgery is performed the in prone position, distal fixation can be optimally obtained allowing post-operative treatment by cervical orthosis instead of a halo-cast. TES-MEP monitoring has been shown to be a reliable neuromonitoring technique with high clinical relevancy during cervical osteotomy because it allows timely intervention before occurrence of permanent cord damage in a large proportion of the patients.
Aquilina, Peter; Parr, William C.H.; Chamoli, Uphar; Wroe, Stephen; Clausen, Philip
2014-01-01
The most stable pattern of internal fixation for mandibular condyle fractures is an area of ongoing discussion. This study investigates the stability of three patterns of plate fixation using readily available, commercially pure titanium implants. Finite element models of a simulated mandibular condyle fracture were constructed. The completed models were heterogeneous in bone material properties, contained approximately 1.2 million elements and incorporated simulated jaw adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. No human subjects were involved in this investigation. The stability of the simulated condylar fracture reduced with the different implant configurations, and the von Mises stresses of a 1.5-mm X-shaped plate, a 1.5-mm rectangular plate, and a 1.5-mm square plate (all Synthes (Synthes GmbH, Zuchwil, Switzerland) were compared. The 1.5-mm X plate was the most stable of the three 1.5-mm profile plate configurations examined and had comparable mechanical performance to a single 2.0-mm straight four-hole plate. This study does not support the use of rectangular or square plate patterns in the open reduction and internal fixation of mandibular condyle fractures. It does provide some support for the use of a 1.5-mm X plate to reduce condylar fractures in selected clinical cases. PMID:25136411
Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S
2016-05-18
Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.
[Finite element study of maxillary Le Fort-I osteotomy with rigid internal fixation].
Zhou, Jian; Sun, Geng-Lin; Wu, Wei; Xu, Chong-Tao; Wang, Peng-Lin
2010-05-01
To study the biomechanical characteristic of maxillary Le fort- I osteotomy with rigid internal fixation (RIF) , so as to choose best fixation method. The 3-dimensional finite element models of maxillary Le Fort-I osteotomy with 9 kinds of RIF methods were established. Then the models were divided into three groups to calculate the stress distribution of the maxilla and the displacement of bone segment under 3 kinds of occlusion condition. The fixation stability of the different RIF methods was evaluated. Under the incisor occlusion condition, the stress of the cranio maxillary complex transmits mainly along the nasal-maxillary buttress. Under the premolar and molar occlusion condition, the stress transmits along the alveolar process first, then turns to the nasal-maxillary and zygomatic-maxillary buttress. The focused stress position of the internal fixation system is at the connection between the screws and the plate and at the plate near the osteotomy line. Under the premolar occlusion condition, the displacement of bone segment with different RIF methods was (in a decreasing order) 0.396509 mm (with bio-absorbable plate), 0.148393 mm (with micro-plate ), 0.078436 mm (with mini-plate) in group 1; 0.188791 mm (fixing at the nasal-maxillary buttress), 0.121718 mm (fixing at the zygomatic-maxillary buttress), 0.078436 mm (fixing at the both buttress) in group 2; 0.091023 mm (with straight plate), 0.078436 mm (with L shape plate), 0.072450 mm (with Y shape plate), 0.065617 mm (with T shape plate) in group 3. The fixation stability of using the bio-absorbable plate in Le Fort-I osteotomy is less stable than using the titanium plate. Fixing at the zygomatic-maxillary buttress is more stable than at the naso-maxillary buttress. The fixation stability is different by using different shapes of plates.
Titanium Mesh Shaping and Fixation for the Treatment of Comminuted Mandibular Fractures.
Dai, Jiewen; Shen, Guofang; Yuan, Hao; Zhang, Wenbin; Shen, Shunyao; Shi, Jun
2016-02-01
Treating comminuted mandibular fractures remains a challenge. In this study, we used titanium mesh to treat comminuted mandibular fractures. Nine patients with traumatically comminuted mandibular fractures who received open reduction and internal stable fixation with titanium mesh were retrospectively reviewed. Open reduction-internal stable fixation was performed 7 to 10 days after primary debridement of the facial trauma. After the fractured mandible and the displaced fragments were reduced, the titanium mesh was reshaped according to the morphology of the mandible, and the reduced bone fragments were fixed with the reshaped titanium mesh and screws. Then, the surgical effects were evaluated during routine follow-up. Most of the displaced fragments were preserved and exhibited a favorable shaping ability in restoring the morphology of the mandible during surgery. No intraoperative complications were encountered. In addition, all patients were infection free, with no obvious resorption in the fixed fragments after surgery. The mandible also exhibited favorable morphology and offered sufficient bone mass for dental implantation or a denture prosthesis. We conclude that titanium mesh shaping and fixation can effectively treat comminuted mandibular fractures with little bone fragment loss, little soft tissue exposure, a low infection rate, and favorable mandibular morphology. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Aquilina, Peter; Chamoli, Uphar; Parr, William C H; Clausen, Philip D; Wroe, Stephen
2013-06-01
The most stable pattern of internal fixation for fractures of the mandibular condyle is a matter for ongoing discussion. In this study we investigated the stability of three commonly used patterns of plate fixation, and constructed finite element models of a simulated mandibular condylar fracture. The completed models were heterogeneous in the distribution of bony material properties, contained about 1.2 million elements, and incorporated simulated jaw-adducting musculature. Models were run assuming linear elasticity and isotropic material properties for bone. This model was considerably larger and more complex than previous finite element models that have been used to analyse the biomechanical behaviour of differing plating techniques. The use of two parallel 2.0 titanium miniplates gave a more stable configuration with lower mean element stresses and displacements over the use of a single miniplate. In addition, a parallel orientation of two miniplates resulted in lower stresses and displacements than did the use of two miniplates in an offset pattern. The use of two parallel titanium plates resulted in a superior biomechanical result as defined by mean element stresses and relative movement between the fractured fragments in these finite element models. Copyright © 2012 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
He, Dongmei; Yang, Chi; Chen, Minjie; Bin, Jiang; Zhang, Xiaohu; Qiu, Yating
2010-07-01
This article reports a modified preauricular approach for intracapsular condyle fracture (ICF) of the mandible and evaluates the stability of various internal fixation methods in the temporomandibular joint (TMJ) division of the Shanghai Ninth People's Hospital. One hundred fifty-one patients with 208 ICFs diagnosed by panoramic radiograph and computed tomographic (CT) scan received open treatment in the TMJ division from 1999 to 2008. Their charts were reviewed. Classification of the fracture was based on coronal CT scan. Forty-three patients also underwent magnetic resonance imaging before the operation to check displacement of the disc. A modified preauricular approach was used for all patients. Various internal fixation methods from wire, to screw, to plate were evaluated for stability. There were 110 ICFs of type A fracture, 60 of type B fracture, 9 of type C fracture, 25 of type M fracture, and 4 fractures without displacement. A modified preauricular approach was used for open treatment, which can better expose and protect the TMJ and superficial temporal vessels. Wire and plate is the commonly used stable fixation method for type A, B, and M fractures, which accounted for 56.7% (101/178). Small fracture fragments were removed with disc repositioning for all type C fractures (n = 9) and some type B (n = 9) and M fractures (n = 5). Three type M fracture and 3 nondisplaced ICFs were treated closed. Eighty-nine patients with 115 ICFs had postoperative CT scan, which showed anatomic and nearly anatomic fracture reduction rates of 95.6%. Thirty-five patients with 44 ICFs had long-term follow-ups from 3 months to 5 years. Among them, 63.2% (n = 12/19) pediatric ICFs had continuous condyle growth after open reduction and rigid fixation; 92% adults had ICFs that healed well (n = 23/25). Postoperative complications were facial nerve injury (n = 3), TMJ clicking (n = 1), and condyle resorption that required plate removal (n = 4). A modified preauricular approach provides better exposure and protection of the TMJ and superficial temporal vessels. Wire and plate provides stable fixation for type A and some type B and M fractures. Open reduction and rigid fixation produce good results for adult patients. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Moore, Amy M; Dennison, David G
2014-06-01
The volar lunate facet fragment of a distal radius fracture may not be stabilized with volar-locked plating alone due to the small size and distal location of the fragment. Identification and stabilization of this small fragment is critical as unstable fixation may result in radiocarpal and radioulnar joint subluxation. The addition of spring wire fixation with volar plating can provide stable internal fixation of this critical fracture fragment. A retrospective review (2006-2011) identified nine patients with distal radius fractures with an associated volar lunate facet fragment that were treated with volar-locked plating and spring wire fixation of the volar lunate facet fragment. Radiographic indices, range of motion, grip strength, and postoperative Patient-related wrist evaluation (PRWE) scores were obtained to assess pain and function. All distal radius fractures healed, and the volar lunate facet fragment reduction was maintained. The mean follow-up was 54 weeks. Mean active range of motion was 46° wrist flexion, 51° wrist extension, 80° pronation, and 68° supination. The mean grip strength was 21 Kg, achieving 66 % of the uninjured limb. The average PRWE score was 17. No patient required removal of hardware or had evidence of tendon irritation. The addition of spring wire fixation to volar-locked plating provided stable fixation of the volar lunate facet fragment of distal radius fractures without complication. This technique addresses a limitation of volar-locked plating to control the small volar lunate facet fragment in distal radius fractures otherwise amenable to volar plating. A retrospective case series, Level IV.
The management of ankle fractures in patients with diabetes.
Wukich, Dane K; Kline, Alex J
2008-07-01
Patients with diabetes mellitus have higher complication rates following both open and closed management of ankle fractures. Diabetic patients with neuropathy or vasculopathy have higher complication rates than both diabetic patients without these comorbidities and nondiabetic patients. Unstable ankle fractures in diabetic patients without neuropathy or vasculopathy are best treated with open reduction and internal fixation with use of standard techniques. Patients with neuropathy or vasculopathy are at increased risk for both soft-tissue and osseous complications, including delayed union and nonunion. Careful soft-tissue management as well as stable, rigid internal fixation are crucial to obtaining a good outcome. Prolonged non-weight-bearing and subsequently protected weight-bearing are recommended following both operative and nonoperative management of ankle fractures in patients with diabetes.
Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you
2015-06-01
To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation,rapid recovery, less complications and good functional recovery, it has better clinical effects.
MacDonald, James H; Agarwal, Sanjeev; Lorei, Matthew P; Johanson, Norman A; Freiberg, Andrew A
2006-03-01
Arthrodesis is one of the last options available to obtain a stable, painless knee in a patient with a damaged knee joint that is not amenable to reconstructive measures. Common indications for knee arthrodesis include failed total knee arthroplasty, periarticular tumor, posttraumatic arthritis, and chronic sepsis. The primary contraindications to knee fusion are bilateral involvement or an ipsilateral hip arthrodesis. A variety of techniques has been described, including external fixation, internal fixation by compression plates, intramedullary fixation through the knee with a modular nail, and antegrade nailing through the piriformis fossa. Allograft or autograft may be necessary to restore lost bone stock or to augment fusion. For the carefully selected patient with realistic expectations, knee arthrodesis may relieve pain and obviate the need for additional surgery or extensive postoperative rehabilitation.
In Situ Subtalar Arthrodesis for Posttraumatic Arthritis of the Calcaneus.
Probe, Robert
2016-08-01
One of the most frequent complications after intraarticular fracture of the calcaneus is the development of posttraumatic arthritis of the subtalar joint. If conservative measures fail in the treatment of this condition, consideration of arthrodesis should be given. This video depicts the preoperative assessment and surgical technique applied to one such 54-year-old patient who had undergone internal fixation of a calcaneal fracture 9 years before. Shown within the video is exposure of the subtalar joint through a lateral incision, joint preparation, and the application of stable fixation. Subtleties of exposure, osteogenesis maximization, and postoperative management are covered.
Wong, Lydia Chwang Yuh; Chiu, Wing Kong; Russ, Matthias; Liew, Susan
2012-03-01
Sacral fractures from high-impact trauma often cause instability in the pelvic ring structure. Treatment is by internal fixation which clamps the fractured edges together to promote healing. Healing could take up to 12 weeks whereby patients are bedridden to avoid hindrances to the fracture from movement or weight bearing activities. Immobility can lead to muscle degradation and longer periods of rehabilitation. The ability to determine the time at which the fracture is stable enough to allow partial weight-bearing is important to reduce hospitalisation time. This review looks into different techniques used for monitoring the fracture healing of bones which could lead to possible methods for in situ and non-invasive assessment of healing fracture in a fixated pelvis. Traditional techniques being used include radiology and CT scans but were found to be unreliable at times and very subjective in addition to being non in situ. Strain gauges have proven to be very effective for accurate assessment of fracture healing as well as stability for long bones with external fixators but may not be suitable for an internally fixated pelvis. Ultrasound provides in situ monitoring of stiffness recovery but only assesses local fracture sites close to the skin surface and has only been tested on long bones. Vibration analysis can detect non-uniform healing due to its assessment of the overall structure but may suffer from low signal-to-noise ratio due to damping. Impedance techniques have been used to assess properties of non-long bones but recent studies have only been conducted on non-biological materials and more research needs to be done before it can be applicable for monitoring healing in the fixated pelvis. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures.
Burnei, C; Popescu, Gh; Barbu, D; Capraru, F
2011-11-14
Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach.
Intramedullary osteosynthesis versus plate osteosynthesis in subtrochanteric fractures
Burnei, C; Popescu, Gh; Barbu, D; Capraru, F
2011-01-01
Due to an ever-aging population and a growing prevalence of osteoporosis and motor vehicle accidents, the number of subtrochanteric fractures is increasing worldwide. The choice of the appropriate implant continues to be critical for fixation of unstable hip fractures. The subtrochanteric region has certain anatomical and biomechanical features that can make fractures in this region difficult to treat. The preferred type of device is a matter of debate. Increased understandings of biomechanical characteristics of the hip and improvement of the implant materials have reduced the incidence of complications. The surgeons choose between the two methods according to Seinsheimer's classification and also to their personal preferences. As a general principle, the open reduction and internal fixation were performed in stable fractures, and the closed reduction and internal fixation were performed in unstable fractures. The advantages of intramedullary nailing consist in a small skin incision, lower operating times, preservation of fracture hematoma and the possibility of early weight bearing. The disadvantages consist in a difficult closed reduction due to important muscular forces, although the nail can be used as a reduction instrument, and higher implant cost. In open reduction internal fixation techniques, the advantage is represented by anatomical reduction which, in our opinion, is not necessary. The disadvantages are represented by: higher operating time, demanding surgery, large devascularization, higher infection rates, late weight bearing, medial instability, refracture after plate removal and inesthetic approach. PMID:22514563
Thukral, Rajiv; Marya, SKS; Singh, Chandeep
2015-01-01
Background: Management of periprosthetic supracondylar femoral fractures is difficult. Osteoporosis, comminution and bone loss, compromise stability with delayed mobility and poor functional outcomes. Open reduction and internal fixation (ORIF) with anatomic distal femoral (DF) locking plate permits early mobilization. However, this usually necessitates bone grafting (BG). Biological fixation using minimally invasive techniques minimizes periosteal stripping and morbidity. Materials and Methods: 31 patients with comminuted periprosthetic DF fractures were reviewed retrospectively from October 2006 to September 2012. All patients underwent fixation using a DF locking compression plate (Synthes). 17 patients underwent ORIF with primary BG, whereas 14 were treated by closed reduction (CR) and internal fixation using biological minimally invasive techniques. Clinical and radiological followup were recorded for an average 36 months. Results: Mean time to union for the entire group was 5.6 months (range 3-9 months). Patients of ORIF group took longer (Mean 6.4 months, range 4.5-9 months) than the CR group (mean 4.6 months, range 3-7 months). Three patients of ORIF and one in CR group had poor results. Mean knee society scores were higher for CR group at 6 months, but nearly identical at 12 months, with similar eventual range of motion. Discussion: Locked plating of comminuted periprosthetic DF fractures permits stable rigid fixation and early mobilization. Fixation using minimally invasive biological techniques minimizes morbidity and may obviate the need for primary BG. PMID:26015610
Wang, Benjie; Zhao, Dewei; Guo, Lin; Yang, Lei; Li, Zhigang; Cui, Daping; Tian, Fengde; Liu, Baoyi
2011-05-01
To explore the effectiveness of pedicled iliac bone graft transposition for treatment of avascular necrosis of femoral head (ANFH) after femoral neck fracture. Between June 2002 and December 2006, 22 cases (22 hips, 16 left hips and 6 right hips) of ANFH after femoral neck fracture were treated with iliac bone graft pedicled with ascending branch of the lateral femoral circumflex vessels. There were 18 males and 4 females with an age range from 28 to 48 years (mean, 37.5 years). The time from injury to internal fixation was 2-31 days, and all fractures healed within 12 months after internal fixation. The ANFH was diagnosed at 15-40 months (mean, 22 months) after internal fixation. The ANFH duration was 3-11 months (mean, 8 months). According to Association Research Circulation Osseous (ARCO) staging system, 2 hips were classified as stage IIa, 3 hips as stage IIb, 3 hips as stage IIc, 3 hips as stage IIIa, 7 hips as stage IIIb, and 4 hips as stage IIIc. The preoperative Harris hip score (HHS) was 64.10 +/- 5.95. All incisions healed by first intention and the patients had no complication of lung embolism, sciatic nerve injury, lower limb deep venous thrombosis, and numbness and pain of donor site. All patients were followed up 2.5 to 6.3 years (mean, 4.8 years). The fracture healing time was 8-12 months, and no femoral neck fracture recurred. The HHS was 90.20 +/- 5.35 at last follow-up, showing significant difference when compared with the preoperative value (t = -18.447, P = 0.000). The hip function were excellent in 11 hips, good in 10 hips, fair in 1 hip, and the excellent and good rate was 95.5%. Four hips were radiographically progressed in ARCO staging, 18 hips remained stable with a stable rate of 81.8%. Pedicled iliac bone graft transposition is an ideal option for treatment of ANFH after internal fixation of femoral neck fracture for the advantages of femoral head revascularization, sufficient cancellous bone supply, and relatively simple procedure.
Morgan, S J; Thordarson, D B; Shepherd, L E
1999-06-01
Six patients with ankle joint destruction and delayed metaphyseal union after tibial plafond fracture were surgically treated with tibiotalar arthrodesis and metaphyseal reconstruction, using a fixed-angle cannulated blade-plate. The procedure was performed through a posterior approach in five cases and a lateral approach in one case. The subtalar joint was preserved in all cases. Metaphyseal union and a stable arthrodesis were obtained in all cases without loss of fixation and with no mechanical failure of the blade-plate. Union was obtained in an average of 26 weeks. No secondary procedures were required to obtain union. All six patients were ambulatory at last follow-up. Stable internal fixation for simultaneous tibiotalar fusion and metaphyseal reconstruction can be achieved with a cannulated blade-plate while preserving the subtalar joint in complex plafond fractures.
[Arthroscopic reconstruction of anterior cruciate ligament with press-fit technique].
Halder, A M
2010-08-01
Problems related to the use of interference screws for fixation of bone-patellar tendon-bone grafts for anterior cruciate ligament (ACL) replacement have led to increasing interest in press-fit techniques. Most of the described techniques use press-fit fixation on either the femoral or tibial side. Therefore an arthroscopic technique was developed which achieves bone-patellar tendon-bone graft fixation by press-fit on both sides without the need for supplemental fixation material. The first consecutive 40 patients were examined clinically with a KT-1000 arthrometer and radiologically after a mean of 28.7 months (range 20-40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2 mm) and the results according to the International Knee Documentation Committee (IKDC) score were as follows: 7 A, 28 B, 5 C, 0 D. The presented press-fit technique avoids all complications related to the use of interference screws. It achieves primary stable fixation of the bone-patellar tendon-bone graft thereby allowing early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding. The results showed reliable stabilization of the operated knees.
Halder, Andreas M; Ludwig, Silke; Neumann, Wolfram
2002-01-01
Patellar tendon autograft fixation in arthroscopic anterior cruciate ligament reconstruction is commonly accomplished using interference screws. However, improper insertion of the screws may reduce primary stability, injure the posterior femoral cortex, or displace hardware into the joint. Even if placed properly, metallic screws interfere with postoperative magnetic resonance imaging. In case of revision surgery, removing screws may be difficult and leaves bone defects. Retrospective study. An arthroscopic technique was developed that achieves patellar tendon autograft fixation by press-fit without any supplemental internal fixation. Forty patients were examined clinically and by KT-1000 arthrometer 28.7 months (range, 22 to 40 months) postoperatively. The mean difference in side-to-side laxity was 1.3 mm (SD 2.2) and the results according to the IKDC score were as follows: 7 A, 28 B, 5 C, and 0 D. The double press-fit technique we present avoids all complications related to the use of interference screws and creates an ideal environment for osseous integration of the bone-patellar tendon-bone autograft. Concurrently, it achieves a stable fixation of the autograft and allows early functional rehabilitation. However, fixation strength depends on bone quality and the arthroscopic procedure is demanding.
Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.
Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S
1979-01-01
The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.
Open reduction internal fixation of the unstable mallet fracture.
Phadnis, Joideep; Yousaf, Sohail; Little, Nicholas; Chidambaram, Ramiah; Mok, Daniel
2010-09-01
Unstable mallet fractures of the digit pose a challenge when treated surgically. We present the results of a technique, not earlier described, for the fixation of these uncommon injuries. The technique involves anatomical reduction and stable fixation of the distal articular fragment combined with stabilization of the distal interphalangeal joint with buried Kirschner wires allowing early mobilization of the digit. Twenty patients with an average follow-up of 12.7 months (10 mo to 21 mo) are presented. Results were good/excellent (Crawford's criteria) in 16 patients, fair in 3, and poor in 1 with those operated upon within 2 weeks postinjury achieving the best results. There were no incidences of fixation failure, loss of reduction, or posttraumatic osteoarthritis. One patient had a minor infection, but there were no cases of nail deformity or wound breakdown. There was high patient satisfaction and all patients returned to work after treatment. We conclude that this is a reliable technique with minimal complications and is comparable with other published operative and nonoperative treatment modalities.
Oh, Hyoung-Keun; Choo, Suk-Kyu; Kim, Ji-Wan; Lee, Mark
2015-12-01
We present the surgical technique of separate vertical wiring for displaced inferior pole fractures of the patella combined with Krachow suture and report the surgical outcomes. Between September 2007 to May 2012, 11 consecutive patients (mean age, 54.6 years) with inferior pole fractures of the patella (AO/OTA 34-A1) were retrospectively enrolled in this study. Through longitudinal incision, all patients underwent open reduction and internal fixation by separate vertical wiring combined with Krackow suture. The range of motion, loss of fixation, and Bostman score were primary outcome measures. The union time was 10 weeks after surgery on average (range: 8-12). No patient had nonunion, loss of reduction and wire breakage. There was no case of wound problem and irritation from the implant. At final follow-up, the average range of motion arc was 129.4° (range: 120-140). The mean Bostman score at last follow-up was 29.6 points (range: 28-30) and graded excellent in all cases. Separate vertical wiring combined with Krackow suture for inferior pole fractures of the patella is a useful technique that is easy to perform and can provide stable fixation with excellent results in knee function. Copyright © 2015 Elsevier Ltd. All rights reserved.
The floating knee: a review on ipsilateral femoral and tibial fractures
Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros
2016-01-01
In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916
Facaros, Zacharia; Ramanujam, Crystal L.; Stapleton, John J.
2010-01-01
The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws) to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF) of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This techniqu may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss. PMID:22396812
Kopylov, Philippe; Geijer, Mats; Tägil, Magnus
2009-01-01
Background and purpose In unstable distal radial fractures that are impossible to reduce or to maintain in reduced position, the treatment of choice is operation. The type of operation and the choice of implant, however, is a matter of discussion. Our aim was to investigate whether open reduction and internal fixation would produce a better result than traditional external fixation. Methods 50 patients with an unstable or comminute distal radius fracture were randomized to either closed reduction and bridging external fixation, or open reduction and internal fixation using the TriMed system. The primary outcome parameter was grip strength, but the patients were followed for 1 year with objective clinical assessment, subjective outcome using DASH, and radiographic examination. Results At 1 year postoperatively, grip strength was 90% (SD 16) of the uninjured side in the internal fixation group and 78% (17) in the external fixation group. Pronation/supination was 150° (15) in the internal fixation group and 136° (20) in the external fixation group at 1 year. There were no differences in DASH scores or in radiographic parameters. 5 patients in the external fixation group were reoperated due to malunion, as compared to 1 in the internal fixation group. 7 other cases were classified as radiographic malunion: 5 in the external fixation group and 2 in the internal fixation group. Interpretation Internal fixation gave better grip strength and a better range of motion at 1 year, and tended to have less malunions than external fixation. No difference could be found regarding subjective outcome. PMID:19857180
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Jin, Jiewen; Meng, Jia; Wang, Jun; Zhao, Jianning; Sun, Guojing; Qian, Hongbo
2017-01-01
To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled.
Wang, Yicun; Jiang, Hui; Deng, Zhantao; Meng, Jia; Wang, Jun
2017-01-01
Background To compare the salvage rate and complication between internal fixation and external fixation in patients with small bone defects caused by chronic infectious osteomyelitis debridement. Methods 125 patients with chronic infectious osteomyelitis of tibia fracture who underwent multiple irrigation, debridement procedure, and local/systemic antibiotics were enrolled. Bone defects, which were less than 4 cm, were treated with bone grafting using either internal fixation or monolateral external fixation. 12-month follow-up was conducted with an interval of 3 months to evaluate union of bone defect. Results Patients who underwent monolateral external fixation had higher body mass index and fasting blood glucose, longer time since injury, and larger bone defect compared with internal fixation. No significant difference was observed in incidence of complications (23.5% versus 19.3%), surgery time (156 ± 23 minutes versus 162 ± 21 minutes), and time to union (11.1 ± 3.0 months versus 10.9 ± 3.1 months) between external fixation and internal fixation. Internal fixation had no significant influence on the occurrence of postoperation complications after multivariate adjustment when compared with external fixation. Furthermore, patients who underwent internal fixation experienced higher level of daily living scales and lower level of anxiety. Conclusions It was relatively safe to use internal fixation for stabilization in osteomyelitis patients whose bone defects were less than 4 cm and infection was well controlled. PMID:29333448
Use of resorbable plates and screws in pediatric facial fractures.
Eppley, Barry L
2005-03-01
The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. No long-term implant-related complications were seen in any of the treated patients. Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.
Iliac screw for reconstructing posterior pelvic ring in Tile type C1 pelvic fractures.
Li, Yonggang; Sang, Xiguang; Wang, Zhiyong; Cheng, Lin; Liu, Hao; Qin, Tao; Di, Kai
2018-06-18
It is often difficult to achieve stable fixation in Tile type C1 pelvic fractures and there is no standard fixation technique for these types of injuries. Iliac screw fixation can be used for treating Type C1 pelvic fractures. A retrospective review was performed on 47 patients who underwent iliac screw fixation in posterior column of ilium (PCI) for Tile type C1 pelvic fractures from July 2007 to December 2014. All patients were treated with fracture reduction, sacral nerve root decompression (if needed), internal fixation by iliac screw and connecting rod. The data on surgical time, intraoperative bleeding volume, postoperative neurologic functions and postoperative complications were analyzed. Patients were follow-up for at least 12months. The mean surgical time was 148minutes, and the mean intraoperative bleeding volume was 763ml. Patients were encouraged in-bed activities immediately after surgery. The postoperative Majeed functional score was 48-100 points (mean 80.2), corresponding to an excellent and good recovery of 91.5%. Postoperative X-radiographs and CT scans indicated satisfactory fracture reduction. Iliac screw fixation combined with sacral nerve canal decompression could effectively restore pelvic alignment and improve neurological functions for complex pelvic trauma. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul
2012-09-27
We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.
Claessen, Femke M A P; Stoop, Nicky; Doornberg, Job N; Guitton, Thierry G; van den Bekerom, Michel P J; Ring, David
2016-10-01
Stable fixation of distal humerus fracture fragments is necessary for adequate healing and maintenance of reduction. The purpose of this study was to measure the reliability and accuracy of interpretation of postoperative radiographs to predict which implants will loosen or break after operative treatment of bicolumnar distal humerus fractures. We also addressed agreement among surgeons regarding which fracture fixation will loosen or break and the influence of years in independent practice, location of practice, and so forth. A total of 232 orthopedic residents and surgeons from around the world evaluated 24 anteroposterior and lateral radiographs of distal humerus fractures on a Web-based platform to predict which implants would loosen or break. Agreement among observers was measured using the multi-rater kappa measure. The sensitivity of prediction of failure of fixation of distal humerus fracture on radiographs was 63%, specificity was 53%, positive predictive value was 36%, the negative predictive value was 78%, and accuracy was 56%. There was fair interobserver agreement (κ = 0.27) regarding predictions of failure of fixation of distal humerus fracture on radiographs. Interobserver variability did not change when assessed for the various subgroups. When experienced and skilled surgeons perform fixation of type C distal humerus fracture, the immediate postoperative radiograph is not predictive of fixation failure. Reoperation based on the probability of failure might not be advisable. Diagnostic III. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Domos, Peter; Tytherleigh-Strong, Graham; Van Rensburg, Lee
2017-01-01
Adult mid-shaft clavicle fractures are common injuries. For displaced fractures, open reduction with plate or intramedullary (IM) fixation is the widely used techniques. All methods have their own potential drawbacks, especially related to local soft tissue complications. There is little information about outcome and management of local wound complications after clavicle fracture fixations. Ninety-seven patients underwent open reduction and internal fixation, 17 were treated with IM screw fixation and 80 with plate fixation. Wound complication occurred in eight patients (8.2%) and rates differed significantly between IM and plate fixations (29.4% vs. 3.8%). Patients were assessed on average 58.3 months with visual analogue pain scores (VASs), Oxford Shoulder Score (OSS), and QuickDash (QD) score. Five patients had wound breakdown and three patients had wound erythema. In seven patients with stable fixation, it was possible to "dress and suppress" with average 3 weeks of oral antibiotics. One patient had unstable fixation and required longer antibiotic treatment with early screw removal. One patient developed a chronic discharging wound, requiring debridement and later plate removal. At final follow-up, all wounds remained healed, bony union was achieved in all. The average scores were: VAS 1, OSS 46, and QD 4.5. Good function with dry healed wound and united clavicle can be achieved. Further studies are required to investigate the difference in soft tissue complication rates, which may be due to the IM technique of retrograde drilling with a guide wire and due to aseptic thermal bone necrosis, rather than true infection.
Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F
2015-03-31
This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P < 0.05); however, there were no significant differences in radial-ulnar deviation, wrist range of motion, or wrist function score between groups (P > 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.
Nelson, Joshua D; McIff, Terence E; Moodie, Patrick G; Iverson, Jamey L; Horton, Greg A
2010-03-01
Internal fixation of the os calcis is often complicated by prolonged soft tissue management and posterior facet disruption. An ideal calcaneal construct would include minimal hardware prominence, sturdy posterior facet fixation and nominal soft tissue disruption. The purpose of this study was to develop such a construct and provide a biomechanical analysis comparing our technique to a standard internal fixation technique. Twenty fresh-frozen cadaver calcanei were used to create a reproducible Sanders type-IIB calcaneal fracture pattern. One calcaneus of each pair was randomly selected to be fixed using our compressive headless screw technique. The contralateral matched calcaneus was fixed with a nonlocking calcaneal plate in a traditional fashion. Each calcaneus was cyclically loaded at a frequency of 1 Hz for 4000 cycles using an increasing force from 250 N to 1000 N. An Optotrak motion capturing system was used to detect relative motion of the three fracture fragments at eight different points along the fracture lines. Horizontal separation and vertical displacement at the fracture lines was recorded, as well as relative rotation at the primary fracture line. When the data were averaged, there was more horizontal displacement at the primary fracture line of the plate and screw construct compared to the headless screw construct. The headless screw construct also had less vertical displacement at the primary fracture line at every load. On average those fractures fixed with the headless screw technique had less rotation than those fixed with the side plate technique. A new headless screw technique for calcaneus fracture fixation was shown to provide stability as good as, or better than, a standard side plating technique under the axial loading conditions of our model. Although further testing is needed, the stability of the proposed technique is similar to that typically provided by intramedullary fixation. This fixation technique provides a biomechanically stable construct with the potential for a minimally invasive approach and improved post-operative soft tissue healing.
Internal Versus External Fixation of Charcot Midfoot Deformity Realignment.
Lee, Daniel J; Schaffer, Joseph; Chen, Tien; Oh, Irvin
2016-07-01
Internal and external fixation techniques have been described for realignment and arthrodesis of Charcot midfoot deformity. There currently is no consensus on the optimal method of surgical reconstruction. This systematic review compared the clinical results of surgical realignment with internal and external fixation, specifically in regard to return to functional ambulation, ulcer occurrence, nonunion, extremity amputation, unplanned further surgery, deep infection, wound healing problems, peri- or intraoperative fractures, and total cases with any complication. A search of multiple databases for all relevant articles published from January 1, 1990, to March 22, 2014, was performed. A logistic regression model evaluated each of the outcomes and its association with the type of fixation method. The odds of returning to functional ambulation were 25% higher for internal fixation (odds ratio [OR], 1.259). Internal fixation had a 42% reduced rate of ulcer occurrence (OR, 0.578). External fixation was 8 times more likely to develop radiographic nonunion than internal fixation (OR, 8.2). Internal fixation resulted in a 1.5-fold increase in extremity amputation (OR, 1.488), a 2-fold increase in deep infection (OR, 2.068), a 3.4-fold increase in wound healing complications (OR, 3.405), and a 1.5-fold increase in the total number of cases experiencing any complication (OR, 1.525). This was associated with a 20% increase in the need for unplanned further surgery with internal fixation (OR, 1.221). Although internal fixation may decrease the risk of nonunion and increase return to functional ambulation, it had a higher rate of overall complications than external fixation for realignment and arthrodesis of Charcot midfoot deformity. [Orthopedics. 2016; 39(4):e595-e601.]. Copyright 2016, SLACK Incorporated.
Fujita, Masaru; Diab, Mohammad; Xu, Zheng; Puttlitz, Christian M
2006-09-01
An in vitro biomechanical calf thoracic spine study. To evaluate the biomechanical stability of sublaminar and subtransverse process fixation using stainless steel wires and ultra-high molecular weight polyethylene (UHMWPE) cables. It is commonly held that transverse process fixation provides less stability than sublaminar fixation. To our knowledge, this is the first biomechanical study to compare the stability afforded by sublaminar fixation and subtransverse process fixation using metal wire and UHMWPE cable before and after cyclic loading. There were 6 fresh-frozen calf thoracic spines (T4-T9) used to determine the sublaminar fixation stiffness and subtransverse process fixation stiffness in each group. Double strands of 18-gauge stainless steel wire, 3 and 5 mm-width UHMWPE cable (Nesplon; Alfresa, Inc., Osaka, Japan) were applied to each spine. Cyclic pure flexion-extension moment loading (2 Nm, 0.5 Hz, 5000 cycles) was applied after the initial stability was analyzed by measuring the range of motion. Statistical analyses were used to delineate differences between the various experimental groups. Subtransverse process wiring was more stable than sublaminar wiring after cyclic loading in flexion-extension (P < 0.05). There were no significant differences between each group in lateral bending and axial rotation after cyclic loading. Sublaminar stainless steel wiring was more stable than sublaminar 3 and 5-mm cable before and after cyclic loading in axial rotation (P < 0.01). Acute subtransverse process fixation using 3-mm cable was less stable after cyclic loading in axial rotation (P < 0.05). All other groups did not produce statistically significant differences. Subtransverse process fixation provides at least as much stability as sublaminar fixation. A 5-mm UHMWPE cable and stainless steel wire result in equivalent sublaminar and subtransverse process stability.
Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L
2016-12-20
Objective: To make a systematic assessment of the complications of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Method: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed.The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected.The included trials were screened out strictly based on the criterion of inclusion and exclusion.The quality of included trials was evaluated.RevMan 5.0 was used for data analysis. Result: A total of 17 studies involving 1 402 patients were included.There were 687 patients with open reduction and internal fixation and 715 with external fixation.The results of Meta-analysis indicated that there were statistically significant differences with regard to the postoperatively total complications, infection, malunion, tendon rupture ( I 2 =8%, RR =0.77(95% CI 0.65-0.91, Z =3.10, P <0.05). There were no statistically significant differences observed between two approaches with respect to nounion, re-operation, complex regional pain syndrome, carpal tunnel syndrome, neurapraxia, tendonitis, painful hardware, scar( P >0.05). Conclusion: Postoperative complications are present in both open reduction and internal fixation and external fixation.Compared with external fixation, open reduction and internal fixation is lower in total complications postoperatively, infection and malunion, but external fixation has lower tendon rupture incidence.
Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan
2017-02-23
Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.
O'Regan, Barry; Devine, Maria; Bhopal, Sats
2013-01-01
Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763
Eighth international congress on nitrogen fixation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
Eighth international congress on nitrogen fixation. Final program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-12-31
This volume contains the proceedings of the Eighth International Congress on Nitrogen Fixation held May 20--26, 1990 in Knoxville, Tennessee. The volume contains abstracts of individual presentations. Sessions were entitled Recent Advances in the Chemistry of Nitrogen Fixation, Plant-microbe Interactions, Limiting Factors of Nitrogen Fixation, Nitrogen Fixation and the Environment, Bacterial Systems, Nitrogen Fixation in Agriculture and Industry, Plant Function, and Nitrogen Fixation and Evolution.
[Early operative treatment of pelvic fractures associated with urethral disruption].
Jia, Jian; Guo, Lu-Zeng; Wu, Chang-Lin; Chen, Jia-Geng; Zhang, Tie-Liang; Pei, Fu-Xing
2007-02-15
To evaluate the early operative treatment and clinical results of pelvic fractures associated with urethra disruption. From January 1995 to January 2005, 25 patients suffered from pelvic fractures combined urethra disruption treated by operation were retrospectively analyzed. According to Tile's classification, 1 case was stable pelvic fracture, 17 rotational unstable fractures, and 7 rotational combined vertical unstable fractures. The complete urethra rupture were in 23 cases and incomplete in 2 cases. The operative methods included: (1) emergency open reduction and internal fixation of the pelvis combined primary urethra suturing in 2 cases, partial suturing after realignment in 4 cases, realignment in 2 cases, and urethrovaginal penetrating wound repairing in 1 case; (2) primary urethra realignment only and delayed (range, 7 to 21 days) pelvic internal fixation in 10 cases; (3) early cystostomy and delayed (range, 3 to 21 days) urethra realignment and pelvic internal fixation in 6 cases. The mean follow-up time of all patients was 34 months (range from 6 to 120 months). According to Majeed's evaluation, 17 cases of pelvic injury showed excellent results, 5 good, and 3 fare. After urinary catheter removed, the mean maximal urine flow rate of 19 (76%) patients was 18.6 ml/s and the mean scar length between both disrupted ends on the film of excretion urethrography was 0.51 cm. Five (20%) cases suffered in dysuria needed urethral dilatation or further surgery. One (4%) female could not control urination who need a second-look operation. The primary suprapubic soft tissue avulsion wound infection secondary to retropubic abscess was found in 1 case, posterior urethra-stenosis in 5 cases, sexual impotence in 3 cases, and incontinence in 1 case. The satisfactory reduction and effective fixation of the pelvic fractures is an anatomical basis for receiving "tension-free urethral anastomosis".
Complications of ankle fracture in patients with diabetes.
Chaudhary, Saad B; Liporace, Frank A; Gandhi, Ankur; Donley, Brian G; Pinzur, Michael S; Lin, Sheldon S
2008-03-01
Ankle fractures in patients with diabetes mellitus have long been recognized as a challenge to practicing clinicians. Complications of impaired wound healing, infection, malunion, delayed union, nonunion, and Charcot arthropathy are prevalent in this patient population. Controversy exists as to whether diabetic ankle fractures are best treated noninvasively or by open reduction and internal fixation. Patients with diabetes are at significant risk for soft-tissue complications. In addition, diabetic ankle fractures heal, but significant delays in bone healing exist. Also, Charcot ankle arthropathy occurs more commonly in patients who were initially undiagnosed and had a delay in immobilization and in patients treated nonsurgically for displaced ankle fractures. Several techniques have been described to minimize complications associated with diabetic ankle fractures (eg, rigid external fixation, use of Kirschner wires or Steinmann pins to increase rigidity). Regardless of the specifics of treatment, adherence to the basic principles of preoperative planning, meticulous soft-tissue management, and attention to stable, rigid fixation with prolonged, protected immobilization are paramount in minimizing problems and yielding good functional outcomes.
Pseudoelastic intramedullary nailing for tibio-talo-calcaneal arthrodesis.
Yakacki, Christopher M; Gall, Ken; Dirschl, Douglas R; Pacaccio, Douglas J
2011-03-01
Tibio-talo-calcaneal (TTC) arthrodesis is a procedure to treat severe ankle arthropathy by providing a pain-free and stable fusion. Intramedullary (IM) nails offer a method of internal fixation for TTC arthrodesis by providing compressive stability, as well as shear and torsional rigidity. IM nails have been developed to apply compression to the TTC complex during installation; however, current designs are highly susceptible to a loss of compression when exposed to small amounts of bone resorption and cyclic loading. Nickel titanium (NiTi) is a shape-memory alloy capable of recovering large amounts of deformation via shape-memory or pseudoelasticity. Currently, the next generation of IM nails is being developed to utilize the adaptive, pseudoelastic properties of NiTi and provide a fusion nail that is resistant to loss of compression or loosening. Specifically, the pseudoelastic IM nail contains an internal NiTi compression element that applies sustained compression during the course of fusion, analogous to external fixators. © 2011 Expert Reviews Ltd
[Comparison of external fixation with or without limited internal fixation for open knee fractures].
Li, K N; Lan, H; He, Z Y; Wang, X J; Yuan, J; Zhao, P; Mu, J S
2018-03-01
Objective: To explore the characteristics and methods of different fixation methods and prevention of open knee joint fracture. Methods: The data of 86 cases of open knee joint fracture admitted from January 2002 to December 2015 in Department of Orthopaedics, Affiliated Hospital of Chengdu University were analyzed retrospectively.There were 65 males and 21 females aged of 38.6 years. There were 38 cases treated with trans articular external fixation alone, 48 cases were in the trans articular external fixation plus auxiliary limited internal fixation group. All the patients were treated according to the same three stages except for different fixation methods. Observation of external fixation and fracture fixation, fracture healing, wound healing and treatment, treatment and related factors of infection control and knee function recovery. χ(2) test was used to analyze data. Results: Eleven patients had primary wound healing, accounting for 12.8%. Seventy-five patients had two wounds healed, accounting for 87.2%. Only 38 cases of trans articular external fixator group had 31 cases of articular surface reduction, accounting for 81.6%; Five cases of trans articular external fixator assisted limited internal fixation group had 5 cases of poor reduction, accounting for 10.4%; There was significant difference between the two groups (χ(2)=44.132, P <0.05). Take a single cross joint external fixation group, a total of 23 cases of patients with infection, accounted for 60.5% of external fixation group; trans articular external fixation assisted limited internal fixation group there were 30 cases of patients with infection, accounting for the assistance of external fixator and limited internal fixation group 62.5%; There was significant difference between the two groups(χ(2)=0.035, P >0.05). Five cases of fracture nonunion cases of serious infection, patients voluntarily underwent amputation. The Lysholm Knee Scale: In the external fixation group, 23 cases were less than 50 points, accounting for 60.5%, 15 cases were more than 50 points, accounting for 39.5%, external fixation and limited internal fixation group 20 cases were less than 50 points, accounting for 41.7%, 28 cases were more than 50 points, accounting for 58.3%; There was significant difference between the two groups(χ(2)=1.279, P >0.05). Conclusions: Prevention and control of infection is a central link in the treatment of open fracture of the knee. Trans articular external fixator plus limited internal fixation is an important measure to treat open fracture of the knee-joint.
Duan, Da-Peng; You, Wu-Lin; Ji, Le; Zhang, Yong-Tao; Dang, Xiao-Qian; Wang, Kun-Zheng
2014-01-01
To analyze the effects of three surgical operations in the treatment of Pilon fracture of Rüedi-Allgower type III, and put forward the best therapeutic method. The clinical data of 33 patients with Pilon fracture who received surgical operations (plaster immobilization group, 10 cases; distal tibia anatomical plate group, 11 cases; external fixation with limited internal fixation group, 12 cases) from October 2009 to January 2012 were analyzed. There were 5 males and 5 females, ranging in age from 24 to 61 years in the plaster immobilization group. There were 7 males and 4 females, ranging in age from 21 to 64 years in the distal tibia anatomical plate group. There were 7 males and 5 females, ranging in age from 23 to 67 years in the external fixation with limited internal fixation group. The Ankle X-ray of Pilon fracture after operation, ankle score, early and late complications were collected. Bourne system was used to evaluate ankle joint function. After 8 months to 3 years follow-up, it was found that three kinds of treatment had significant differences in the outcomes and complications (P < 0.05): the external fixation with limited internal fixation group got the best results. The number of anatomic reduction cases in the external fixation with limited internal fixation group (7 cases) and the distal tibia anatomical plate group (8 cases) was more than the plaster immobilization group (2 cases). According to the ankle score, 8 patients got an excellent result, 3 good and 1 poor in the limited internal fixation group ,which was better than those of distal tibia anatomical plate group (5 excellent, 4 good and 2 poor) and the plaster immobilization group (3 excellent, 4 good and 3 poor). The number of early and late complications in the external fixation with limited internal fixation group was more than those in the plaster immobilization group and the distal tibia anatomical plate group (P< 0.05). Treatment of external fixation with limited internal fixation in the treatment of Pilon fracture of Rüedi-Allgower type III is effective and safe.
Biomechanical characteristics of fixation methods for floating pubic symphysis.
Song, Wenhao; Zhou, Dongsheng; He, Yu
2017-03-07
Floating pubic symphysis (FPS) is a relatively rare injury caused by high-energy mechanisms. There are several fixation methods used to treat FPS, including external fixation, subcutaneous fixation, internal fixation, and percutaneous cannulated screw fixation. To choose the appropriate fixation, it is necessary to study the biomechanical performance of these different methods. The goal of this study was to compare the biomechanical characteristics of six methods by finite element analysis. A three-dimensional finite element model of FPS was simulated. Six methods were used in the FPS model, including external fixation (Ext), subcutaneous rod fixation (Sub-rod), subcutaneous plate fixation (Sub-plate), superior pectineal plate fixation (Int-sup), infrapectineal plate fixation (Int-ifa), and cannulated screw fixation (Int-scr). Compressive and rotational loads were then applied in all models. Biomechanical characteristics that were recorded and analyzed included construct stiffness, micromotion of the fracture gaps, von Mises stress, and stress distribution. The construct stiffness of the anterior pelvic ring was decreased dramatically when FPS occurred. Compressive stiffness was restored by the three internal fixation and Sub-rod methods. Unfortunately, rotational stiffness was not restored satisfactorily by the six methods. For micromotion of the fracture gaps, the displacement was reduced significantly by the Int-sup and Int-ifa methods under compression. The internal fixation methods and Sub-plate method performed well under rotation. The maximum von Mises stress of the implants was not large. For the plate-screw system, the maximum von Mises stress occurred over the region of the fracture and plate-screw joints. The maximum von Mises stress appeared on the rod-screw and screw-bone interfaces for the rod-screw system. The present study showed the biomechanical advantages of internal fixation methods for FPS from a finite element view. Superior stabilization of the anterior pelvic ring and fracture gaps was obtained by internal fixation. Subcutaneous fixation had satisfactory outcomes as well. Sub-rod fixation offered good anti-compression, while the Sub-plate fixation provided favorable anti-rotational capacity.
Vesnaver, Ales
2008-10-01
Treatment of intra-articular fractures of the mandibular condyle head is conservative at most institutions dealing with facial fractures. Recently, reports had been published about benefits of surgical treatment in these fractures. From July 2004 until the end of June 2006, 13 patients with 16 displaced intra-articular fractures of the mandibular condyle were treated with open reduction and internal fixation at the Department of Oral and Maxillofacial Surgery in Ljubljana, Slovenia, using the preauricular approach and the lag screw technique. Twelve of the 13 patients could open their mouths for 40 mm or more, and 10 had a deflection of the chin of less than 2 mm upon maximal opening. None of the patients experienced pain upon rest, palpation, or chewing. Occlusion was not noted as altered in any of the cases, neither subjectively, nor on examination. There were no cases of postoperative weakness of the temporal branch of the facial nerve. Surgical treatment of intra-articular condyle fractures using the preauricular approach achieves a good exposure and enables proper reduction. Stable fixation of fractured bony fragments can be achieved using the lag screw technique. Another benefit of open exposure is revision and repair of TMJ soft tissues. With the appropriate surgical technique, the surgical procedure is safe and leads to good results.
Outcome of 28 open pilon fractures with injury severity-based fixation.
Danoff, Jonathan R; Saifi, Comron; Goodspeed, David C; Reid, J Spence
2015-04-01
Open pilon fracture management and treatment poses a significant challenge to orthopedic surgeons. The purpose of this study was to determine patient outcomes for open pilon fractures based on wound complication and infection rates, as well as subjective outcome instruments. This was a retrospective consecutive case series of 28 fractures with Orthopaedic Trauma Association (OTA)-type 43-B and 43-C open pilon fractures. Mean length of follow-up was 36 months and minimum of 1 year. Ten fractures were Gustilo and Anderson grade IIIB, and the remaining fractures were grades I-IIIA. Patients were initially treated with spanning external fixation and staged wound debridement followed by osteosynthesis of the articular surface. Metaphyseal fixation was by either plate fixation or Ilizarov frame. The primary outcome was the incidence of deep tissue infection requiring surgery. Secondary outcomes included the incidence of other complications (nonunion, malunion, amputation) and functional outcomes (Short Musculoskeletal Functional Assessment Questionnaire and AAOS Foot and Ankle Questionnaire). Four patients developed deep tissue infections, three in the internal fixation group and one in the Ilizarov group, and all were treated successfully with staged debridement. There were two delayed unions required bone grafting, and infection-free union was ultimately achieved in all fractures. Two patients underwent arthrodesis secondary to post-traumatic arthritis, while no patients experienced malunions or amputations. The use of staged wound debridement in conjunction with either plate fixation or Ilizarov frame achieves low rates of wound infection and stable fixation after anatomic joint reconstruction for OTA-type 43-B and 43-C open pilon fractures.
External fixation using locking plate in distal tibial fracture: a finite element analysis.
Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei
2015-08-01
External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.
Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E
2005-01-01
Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.
Davis, Erika N; Chung, Kevin C; Kotsis, Sandra V; Lau, Frank H; Vijan, Sandeep
2006-04-01
Open reduction and internal fixation and cast immobilization are both acceptable treatment options for nondisplaced waist fractures of the scaphoid. The authors conducted a cost/utility analysis to weigh open reduction and internal fixation against cast immobilization in the treatment of acute nondisplaced mid-waist scaphoid fractures. The authors used a decision-analytic model to calculate the outcomes and costs of open reduction and internal fixation and cast immobilization, assuming the societal perspective. Utilities were assessed from 50 randomly selected medical students using the time trade-off method. Outcome probabilities taken from the literature were factored into the calculation of quality-adjusted life-years associated with each treatment. The authors estimated medical costs using Medicare reimbursement rates, and costs of lost productivity were estimated by average wages obtained from the U.S. Bureau of Labor Statistics. Open reduction and internal fixation offers greater quality-adjusted life-years compared with casting, with an increase ranging from 0.21 quality-adjusted life-years for the 25- to 34-year age group to 0.04 quality-adjusted life-years for the > or =65-year age group. Open reduction and internal fixation is less costly than casting ($7940 versus $13,851 per patient) because of a longer period of lost productivity with casting. Open reduction and internal fixation is therefore the dominant strategy. When considering only direct costs, the incremental cost/utility ratio for open reduction and internal fixation ranges from $5438 per quality-adjusted life-year for the 25- to 34-year age group to $11,420 for the 55- to 64-year age group, and $29,850 for the > or =65-year age group. Compared with casting, open reduction and internal fixation is cost saving from the societal perspective ($5911 less per patient). When considering only direct costs, open reduction and internal fixation is cost-effective relative to other widely accepted interventions.
Anticipatory dynamics of biological systems: from molecular quantum states to evolution
NASA Astrophysics Data System (ADS)
Igamberdiev, Abir U.
2015-08-01
Living systems possess anticipatory behaviour that is based on the flexibility of internal models generated by the system's embedded description. The idea was suggested by Aristotle and is explicitly introduced to theoretical biology by Rosen. The possibility of holding the embedded internal model is grounded in the principle of stable non-equilibrium (Bauer). From the quantum mechanical view, this principle aims to minimize energy dissipation in expense of long relaxation times. The ideas of stable non-equilibrium were developed by Liberman who viewed living systems as subdivided into the quantum regulator and the molecular computer supporting coherence of the regulator's internal quantum state. The computational power of the cell molecular computer is based on the possibility of molecular rearrangements according to molecular addresses. In evolution, the anticipatory strategies are realized both as a precession of phylogenesis by ontogenesis (Berg) and as the anticipatory search of genetic fixation of adaptive changes that incorporates them into the internal model of genetic system. We discuss how the fundamental ideas of anticipation can be introduced into the basic foundations of theoretical biology.
Wang, Dong; Xiang, Jian-Ping; Chen, Xiao-Hu; Zhu, Qing-Tang
2015-01-01
The treatment of tibial plafond fractures is challenging to foot and ankle surgeons. Open reduction and internal fixation and limited internal fixation combined with an external fixator are 2 of the most commonly used methods of tibial plafond fracture repair. However, conclusions regarding the superior choice remain controversial. The present meta-analysis aimed to quantitatively compare the postoperative complications between open reduction and internal fixation and limited internal fixation combined with an external fixator for tibial plafond fractures. Nine studies with 498 fractures in 494 patients were included in the present study. The meta-analysis found no significant differences in bone healing complications (risk ratio [RR] 1.17, 95% confidence interval [CI] 0.68 to 2.01, p = .58], nonunion (RR 1.09, 95% CI 0.51 to 2.36, p = .82), malunion or delayed union (RR 1.24, 95% CI 0.57 to 2.69, p = .59), superficial (RR 1.56, 95% CI 0.43 to 5.61, p = .50) and deep (RR 1.89, 95% CI 0.62 to 5.80) infections, arthritis symptoms (RR 1.20, 95% CI 0.92 to 1.58, p = .18), or chronic osteomyelitis (RR 0.31, 95% CI 0.05 to 1.84, p = .20) between the 2 groups. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Wilke, Benjamin; Houdek, Matthew; Rao, Rameshwar R; Caird, Michelle S; Larson, A Noelle; Milbrandt, Todd
2017-09-01
Little data exist to guide the treatment of unicameral bone cysts in the proximal femur. Methods of treatment include corticosteroid injections, curettage and bone grafting, and internal fixation. The authors completed a multi-institutional, retrospective review to evaluate their experience with proximal femoral unicameral bone cysts. They posed the following questions: (1) Does internal fixation reduce the risk of further procedures for the treatment of a unicameral bone cyst? (2) Is radiographic healing faster with internal fixation? Following institutional review board approval, the authors conducted a retrospective review of 36 patients treated for a unicameral bone cyst of the proximal femur at their institutions between 1974 and 2014. Medical records and radiographs were reviewed to identify patient demographics and treatment outcomes. Tumor locations included femoral neck (n=13), intertrochanteric (n=16), and subtrochanteric (n=7). Initial treatment included steroid injection (n=2), curettage and bone grafting (n=9), and internal fixation with curettage and bone grafting (n=25). Mean time was 9 months to radiographic healing and 15 months to return to full activity. The number of patients requiring additional surgeries was increased among those who did not undergo internal fixation. There was no difference in time to radiographic healing. However, time to return to normal activities was reduced if patients had received internal fixation. A significant reduction in additional procedures was observed when patients had been treated with internal fixation. Although this did not influence time to radiographic healing, patients did return to normal activities sooner. Internal fixation should be considered in the treatment of proximal femoral unicameral bone cysts. [Orthopedics. 2017; 40(5):e862-e867.]. Copyright 2017, SLACK Incorporated.
Kim, Kyeong Hwan; Kim, Wan Soo
2015-09-01
To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism, immediate postoperative inflammation, earlier recurrence, and less stable refraction. Copyright © 2015 Elsevier Inc. All rights reserved.
Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien
2011-09-01
The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.
Radiological evaluation of ankle arthrodesis with Ilizarov fixation compared to internal fixation.
Morasiewicz, Piotr; Dejnek, Maciej; Urbański, Wiktor; Dragan, Szymon Łukasz; Kulej, Mirosław; Dragan, Szymon Feliks
2017-07-01
We asked whether the type of ankle joint arthrodesis stabilization will affect: (1) rate of union, (2) rate of adjacted-joint arthritis, (3) malalignment of the ankle joint. We retrospectively radiological studied 62 patients who underwent ankle arthrodesis with Ilizarov external fixator stabilization (group 1,n=29) or internal stabilization (group 2,n=33) from 2006 to 2015. Radiologic outcomes were mesure by: (1) rate of union, (2) rate of adjacent-joint arthritis, (3) malalignment of the ankle joint. The Levene's test,Mann-Whitney U test and Students t-test were used to the statistical analyses. Ankle fusion was achieved in 100% of patients treated with external fixation and in 88% with internal stabilization. Desired frontal plane alignment was achieved in 100% of patients with external fixation and 76% with internal stabilization. Desired sagittal plane alignment was achieved in 100% of external fixation and 85% of internal stabilization. A total of 14 (48.3%) patients from group 1 showed a radiographic evidence of pre-existing adjacent-joint OA. The radiographic evidence of pre-existing adjacent-joint OA was also found in 27(81.8%) subjects from group 2. Alterations of adjacent joints were also found on postoperative radiograms of 19 (65.5%) patients subjected to Ilizarov fixation and in all 33 patients from group 2. Ilizarov fixation of ankle arthrodesis is associated with lower prevalence of adjacent-joint OA and ankle joint misalignment,and with higher fusion rates than after internal fixation.Although achieving a complex ankle fusion is generally challenging,radiological outcomes after fixation with the Ilizarov apparatus are better than after internal stabilization. Copyright © 2017 Elsevier Ltd. All rights reserved.
Goldzak, M; Simon, P; Mittlmeier, T; Chaussemier, M; Chiergatti, R
2014-01-01
Nowadays, open anatomic reduction and internal fixation can be considered as a valuable treatment for displaced intra-articular fractures of the calcaneus. However, the application of a calcaneal plate via an extensile lateral approach is at risk for a substantial rate of complications including delayed healing, skin necrosis, or infection. There is some evidence that a limited exposure might contribute to a decreased soft tissue complication rate bearing in mind that most minimally invasive techniques have to accept a reduced primary stability compared with the open application of an angular stable plate. Recently, an intrafocal minimal invasive reduction technique has been established employing an intramedullary nail for fracture stabilisation and support of the subtalar joint. The aim of this study was to compare the primary biomechanical performance of the new device versus lateral angular stable plating. Biomechanical testings were performed on 14 human cadaveric feet (7 pairs). Dry calcaneal bones were fractured resulting in a Sanders type IIB fracture pattern and fixed by either a calcaneal locking plate or an intramedullary calcaneal nail. Compressive testing via the corresponding talus was employed at a constant loading velocity until failure with an universal testing machine and a specific mounting device to avoid any shear forces. Apart from the data of the load deformation diagram the relative motion of the fracture elements during loading was recorded by 8 extensometric transducers. After failure the specimens were carefully examined to check the failure patterns. The displacement of the subtalar joint fragment was substantially lower in specimens fixed with the nail. Stiffness and load to failure were significantly higher after fixation with the intramedullary nail than after application of the angular stable plate. Failure with both fixation modes generally occurred at the anterior calcaneal process fragment. The primary stability of an intramedullary nail appeared to be superior to an angular stable plate representing the present standard technique in open reconstruction of the fractured calcaneus. The results from the experimental model speak in favour of the clinical use of the intramedullary calcaneal nail. Copyright © 2013 Elsevier Ltd. All rights reserved.
Ibrahim, Mohammad; Terai, Hidetomi; Yamada, Kentaro; Suzuki, Akinobu; Toyoda, Hiromitsu; Nakamura, Hiroaki
2013-07-01
Patients with long bone metastasis have many therapeutic options, including surgery. However, the appropriate time for surgical intervention and the use of internal fixation prior to impending fracture remains controversial. The purpose of this study was to establish a long bone metastatic model with internal fixation, and to determine whether prophylactic internal fixation for long bone metastasis prior to impending fracture would affect bone destruction, tumor progression, and mortality. We implanted VX2 tumor cells into the tibiae of 45 rabbits divided equally into three groups: internal fixation, control, and sham groups. Rabbits were monitored by X-ray and computed tomography, and blood serum levels were examined every 2 weeks. Computed tomography data revealed significantly higher bone destruction in rabbit tibiae in the sham and control groups compared with those in the fixation group; there were volumetric bone losses of 0.2, 0.4, and 2.3% in the fixation, sham, and control groups, respectively, at 3 weeks, which increased to 1.2, 2.5, and 6.1% at 5 weeks. Rabbits in the fixation group showed significantly prolonged survival (64.5 ± 13.5 days) in comparison with rabbits in the sham group (50.3 ± 11.6 days) and control group (38.2 ± 4.9 days). Our results suggest that prophylactic internal fixation may hinder bone destruction and tumor progression, thus extending the survival period for patients with long bone metastasis.
Klems, H
1976-02-01
High tibial osteotomy has proved its value in the treatment of gonarthrosis with or without axis deformity. The thrust of weight-bearing and other stresses is lessened on the degenerated tibial condyle and transferred to the more normal condyle. The stable fixation by means of external fixation allows early movement of the knee joint.-R-ferences to operative technique, indication, complications and after-treatment.
OʼToole, Robert V; Gary, Joshua L; Reider, Lisa; Bosse, Michael J; Gordon, Wade T; Hutson, James; Quinnan, Stephen M; Castillo, Renan C; Scharfstein, Daniel O; MacKenzie, Ellen J
2017-04-01
The treatment of high-energy open tibia fractures is challenging in both the military and civilian environments. Treatment with modern ring external fixation may reduce complications common in these patients. However, no study has rigorously compared outcomes of modern ring external fixation with commonly used internal fixation approaches. The FIXIT study is a prospective, multicenter randomized trial comparing 1-year outcomes after treatment of severe open tibial shaft fractures with modern external ring fixation versus internal fixation among men and women of ages 18-64. The primary outcome is rehospitalization for major limb complications. Secondary outcomes include infection, fracture healing, limb function, and patient-reported outcomes including physical function and pain. One-year treatment costs and patient satisfaction will be compared between the 2 groups, and the percentage of Gustilo IIIB fractures that can be salvaged without soft tissue flap among patients receiving external fixation will be estimated.
Milenković, Sasa; Mitković, Milorad; Micić, Ivan; Mladenović, Desimir; Najman, Stevo; Trajanović, Miroslav; Manić, Miodrag; Mitković, Milan
2013-09-01
Distal tibial pilon fractures include extra-articular fractures of the tibial metaphysis and the more severe intra-articular tibial pilon fractures. There is no universal method for treating distal tibial pilon fractures. These fractures are treated by means of open reduction, internal fixation (ORIF) and external skeletal fixation. The high rate of soft-tissue complications associated with primary ORIF of pilon fractures led to the use of external skeletal fixation, with limited internal fixation as an alternative technique for definitive management. The aim of this study was to estimate efficacy of distal tibial pilon fratures treatment using the external skeletal and minimal internal fixation method. We presented a series of 31 operated patients with tibial pilon fractures. The patients were operated on using the method of external skeletal fixation with a minimal internal fixation. According to the AO/OTA classification, 17 patients had type B fracture and 14 patients type C fractures. The rigid external skeletal fixation was transformed into a dynamic external skeletal fixation 6 weeks post-surgery. This retrospective study involved 31 patients with tibial pilon fractures, average age 41.81 (from 21 to 60) years. The average follow-up was 21.86 (from 12 to 48) months. The percentage of union was 90.32%, nonunion 3.22% and malunion 6.45%. The mean to fracture union was 14 (range 12-20) weeks. There were 4 (12.19%) infections around the pins of the external skeletal fixator and one (3.22%) deep infections. The ankle joint arthrosis as a late complication appeared in 4 (12.90%) patients. All arthroses appeared in patients who had type C fractures. The final functional results based on the AOFAS score were excellent in 51.61%, good in 32.25%, average in 12.90% and bad in 3.22% of the patients. External skeletal fixation and minimal internal fixation of distal tibial pilon fractures is a good method for treating all types of inta-articular pilon fractures. In fractures types B and C dynamic external skeletal fixation allows early mobility in the ankle joint.
Yang, Z; Yuan, Z Z; Ma, J X; Ma, X L
2017-11-07
Objective: To make a systematic assessment of the Long-term efficacy of open reduction and internal fixation versus external fixation for unstable distal radius fractures. Methods: A computer-based online search of PubMed, ScienceDirect, EMBASE, BIOSIS, Springer and Cochrane Library were performed. The randomized and controlled trials of open reduction and internal fixation versus external fixation for unstable distal radius fractures were collected. The included trials were screened out strictly based on the criterion of inclusion and exclusion. The quality of included trials was evaluated. RevMan 5.0 was used for data analysis. Results: Sixteen studies involving 1 268 patients were included. There were 618 patients with open reduction and internal fixation and 650 with external fixation. The results of meta-analysis indicated that there were statistically significant differences with regard to the complications postoperatively (infection( I (2)=0%, RR =0.27, 95% CI 0.16-0.45, Z =4.92, P <0.000 01) and total complications( I (2)=0%, RR =0.71, 95% CI 0.59-0.85, Z =3.65, P =0.000 3) ), DASH scores( I (2)=37%, MD =-5.67, 95% CI -8.31--3.04, Z =4.22, P <0.000 1) and volar tilt( I (2)=78%, MD =2.29, 95% CI 0.33-4.24, Z =2.30, P =0.02)( P <0.05) at the end of follow-up period were noted. There were no statistically significant differences observed between two approaches with respect to the clinical outcomes (grip strength, flexion, extension, pronation, supination, radial deviation and ulnar deviation) and radiographic outcome(radial length) at the end of follow-up period( P <0.05). Conclusion: Both open reduction and internal fixation and external fixation are effective treatment for unstable distal radius fractures. Compared with external fixation, open reduction and internal fixation provides reduced complications postoperatively, lower DASH scores and better restoration of volar tilt for treatment of distal radius fractures.
Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun
2017-07-01
To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P <0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B ( P <0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference ( χ 2 =0.055, P =0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups ( χ 2 =0.056, P =0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups ( t =-0.028, P =0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P <0.05). The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.
Murphy, Ryan M; Fallat, Lawrence M; Kish, John P
2014-01-01
The distal chevron osteotomy is a widely accepted technique for the treatment of hallux abductovalgus deformity. Although the osteotomy is considered to be stable, displacements of the capital fragment has been described. We propose a new method for fixation of the osteotomy involving the axial loading screw (ALS) used in addition to single screw fixation. We believe this method will provide a more mechanically stable construct. We reviewed the charts of 46 patients in whom 52 feet underwent a distal chevron osteotomy that was fixated with either 1 screw or 2 screws that included the ALS. We hypothesized that the ALS group would have fewer displacements and would heal more quickly than the single screw fixation group. We found that the group with ALS fixation had healed at a mean of 6.5 weeks and that the group with single screw fixation had healed at 9.53 weeks (p = .001). Also, 8 cases occurred of displacement of the capital fragment in the single screw, control group compared with 2 cases of displacement in the ALS group. However, this finding was not statistically significant. The addition of the ALS to single screw fixation allowed the patients to heal approximately 3 weeks earlier than single screw fixation alone. The ALS is a fixation option for the surgeon to consider when osseous correction of hallux abducto valgus is performed. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Long-bone fractures in llamas and alpacas: 28 cases (1998–2008)
Knafo, S. Emmanuelle; Getman, Liberty M.; Richardson, Dean W.; Fecteau, Marie-Eve
2012-01-01
Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998–2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids. PMID:23277645
Long-bone fractures in llamas and alpacas: 28 cases (1998-2008).
Knafo, S Emmanuelle; Getman, Liberty M; Richardson, Dean W; Fecteau, Marie-Eve
2012-07-01
Treatment and outcome of camelids with long-bone fractures are described. Medical records (1998-2008) of camelids (n = 28) with long-bone fractures were reviewed for signalment, time to presentation, fracture type, method of repair, duration of hospitalization, and post-operative complications. Follow-up information was obtained via telephone interviews with owners. Mean age and weight at presentation were 3.4 years and 56.3 kg, respectively. Twenty-six fractures were treated with internal fixation (n = 11), external fixation (n = 10), combination of internal and external fixation (n = 3), amputation (n = 1), and external fixation followed by amputation (n = 1). Long-term follow-up information was obtained for 19 of the 26 animals. The post-operative complication rate was 23% and owner satisfaction was high. Animals with open fractures were more likely to experience complications. Internal fixation was associated with superior alignment and outcome. Internal fixation techniques should be recommended for camelids.
Guo, Zengjing; Cai, Xiaochun; Xie, Jingyan; Wang, Xiaochen; Zhou, Yu; Wang, Jun
2016-05-25
An ionic copolymer catalyst with nanopores, large surface area, high ionic density, and superior basicity was prepared via the radical copolymerization of amino-functionalized ionic liquid bromide and divinylbenzene, followed with a hydroxyl exchange for removing bromonium. Evaluated in chemical fixation of CO2 with epoxides into cyclic carbonates in the absence of any solvent and basic additive, the nanoporous copolymer catalyst showed high and stable activity, superior to various control catalysts including the halogen-containing analogue. Further, high yields were obtained over a wide scope of substrates including aliphatic long carbon-chain alkyl epoxides and internal epoxide, even under atmospheric pressure and less than 100 °C for the majority of the substrates. On the basis of in situ Fourier transform infrared (FT-IR) investigation and density functional theory (DFT) calculation for the reaction intermediates, we proposed a possible reaction mechanism accounting for the superior catalytic activity of the ionic copolymer. The specifically prepared ionic copolymer material of this work features highly stable, noncorrosive, and sustainable catalysis and, thus, may be a new possibility for efficient chemical fixation of CO2 since it is an environmentally friendly, metal-free solid catalyst.
History of internal fixation (part 1): early developments with wires and plates before World War II.
Hernigou, Philippe; Pariat, Jacques
2017-06-01
Though the date at which an orthopaedic implant was first used cannot be ascertained with any certainty, the fixation of bone fracture using an iron wire was reported for the first time in a French manuscript in 1775. The first techniques of operative fracture treatment were developed at the end of the 18th and in the beginning of the 19th centuries. The use of cerclage wires to fix fractures was the most frequent fixation at this time. The French Berenger-Feraud (1832-1900) had written the first book on internal fixation. However internal fixation of fractures could not become a practical method before Lister had ensured the safety of open reduction and internal fixation in the treatment of fractures. Lister is not only the father of asepsis; he also used metal wires to fix even closed fractures. The first internal fixation by means of a plate and screws was described by Carl Hansmann in 1858 in Hamburg. Nevertheless, Arbuthnot Lane (1892) and Albin Lambotte (1905) are considered to be the founders of this method, which was further developed by Sherman in the first part of the 20th century.
Xing, Jin-Ming; Peng, Wen-Ming; Shi, Chu-Yun; Xu, Lei; Pan, Qi-Huao
2013-03-01
To analyze the reason and strategy for failure of posterior pedicle screw short-segment internal fixation on thoracolumbar fractures. From March 2008 to December 2010,the clinical data of 18 patients with thoracolumbar fracture failed in posterior pedicle screw short-segment internal fixation were retrospectively analyzed. There were 11 males and 7 females with an average age of 37.2 years (ranged, 19 to 63). The time from the first operation to complication occurrence was from 6 to 44 months with an average of 14.3 months. Of them,fusion failure was in 7 cases (combined with screw breakage in 4 cases), the progressive neuro-dysfunction was in 5 cases,the progressive lumbodorsal pain was in 6 cases. All 18 patients with kyphosis were treated with anterior internal fixation remaining posterior fixation (9 cases) and anterior internal fixation after posterior fixation removal (9 cases). All the patients were followed up from 18 to 50 months with an average of 30.5 months. No intetnal fixation loosening and breakage were found, moreover, X-ray and lamellar CT showed bone healing well. Preoperative, postoperative at 3 months and at final follow-up, ODI score was respectively 31.6+/-5.1, 8.6+/-5.7, 8.3+/-3.2; VAS score was respectively 7.2+/-2.3, 2.3+/-0.7, 2.1+/-1.1; kyphosis angle was respectively (-21.2/-+7.8 degreeso, (-5.3+/-6.8 degrees ), (-5.8+/-7.8 )degrees. Compared with preoperative data ,above-listed items had obviously ameliorated(P<0.05). Treatment of thoracolumbar fracture with posterior pedicle screw short-segment internal fixation may result in the complications such as bone nonunion ,internal fixation breakage and progressive kyphosis. Anterior reconstruction may be a good strategy for the failure of posterior operation.
Meena, Umesh Kumar; Bansal, Mahesh Chand; Behera, Prateek; Upadhyay, Rahul; Gothwal, Gyan Chand
2017-11-01
The management of pilon fractures is controversial primarily due to the high rate of complications irrespective of the mode of treatment. Limited internal fixation with external fixation is associated with minimal soft tissue handling. This may reduce the chances of wound dehiscence and infection. This study was designed to evaluate the functional and clinical outcomes in patients treated with limited internal fixation combined with external fixation in pilon fractures. This study was conducted as a prospective clinical study on 56 skeletally mature patients with closed fractures with poor skin condition, and with open grade 1 and grade 2 distal tibial intra-articular fractures. All patients were treated with combined limited internal fixation and ankle spanning external fixation. All fractures in this series united with an average time period of union of 18.3weeks (ranging from 13 weeks to 30 weeks). There was no non-union in any case. There was malunion in 4 cases, varus malunion (>5 degree) in 2 cases and recurvatum in another 2 cases). Excellent to good functional results were observed in 88% cases based on the modified Ovadia and Beals score. The mean ankle dorsiflexion and planter flexion movements were 10.2±5.3 degrees and 27.4±7.2 degrees respectively. infections occurred in 6 patients which included 4 pin tract infections and 2 superficial wound infection, all 6 healed after removal of pin tract and with oral antibiotics. The technique of combined external fixation with internal fixation is safe and effective management option for intra-articular distal tibial fractures.
Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi
2018-01-01
To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.
Son, Jang-Ho; Ha, Jinhee; Cho, Yeong-Cheol; Sung, Iel-Yong
2017-08-01
To investigate whether biodegradable plates are applicable in endoscope-assisted open reduction and internal fixation (EAORIF) of mandibular subcondyle fractures. This retrospective case-series study included patients with mandibular subcondyle fractures treated with EAORIF using an unsintered hydroxyapatite particles/poly-l-lactide biodegradable plate system, with at least 6 months of clinical follow-up data available. The outcome variables were fracture healing with postoperative stability and postoperative complications. Other variables included age, gender, fracture site, cause of injury, accompanying mandibular fracture, total follow-up period, fracture classification, extent of displacement, preoperative status of occlusion, preoperative mandibular movements, fixation materials in accompanying mandibular fracture, location and number of fixation plates, periods of intermaxillary fixation/elastic bands, and postoperative mandibular movements. Fracture healing in these patients was assessed by comparing the immediate postoperative cone-beam computed tomography (CBCT) images with those obtained at least 3 months after surgery. A total of 11 patients, 9 male and 2 female, with a mean ± standard deviation age of 35.3 ± 15.9 years, were included. The mean follow-up period was 18.8 ± 7.8 months. Four patients had an accompanying mandibular fracture. Two 4-hole, 2.0-mm biodegradable plates were fixed with 6-mm screws along the posterior border of the mandibular ramus and near the sigmoid notch. Complete bone formation around the fracture lines or fading of the fracture lines, with no change in the position of the fractured segments, was observed on the postoperative CBCT images at 3 months. With the exception of 2 patients, no patient complained of plate palpability, deviation in occlusion, or discomfort during the postoperative follow-up period. EAORIF using biodegradable plates for mandible subcondylar fractures is a stable and reliable method, with considerable advantages compared with titanium plates. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Fixation of tritium in a highly stable polymer form
Steinberg, Meyer; Colombo, Peter; Pruzansky, Jacob
1977-01-01
A method for the fixation of tritium comprising reacting tritiated water with calcium carbide to produce calcium hydroxide and tritiated acetylene, polymerizing the acetylene, and then incorporating the polymer in a solidifying matrix.
Outcomes of internal fixation in a combat environment.
Stinner, Daniel J; Keeney, James A; Hsu, Joseph R; Rush, Jeremy K; Cho, Mickey S; Wenke, Joseph C; Ficke, James R
2010-01-01
Due to the nature of the wounds and environment, internal fixation in battlefield treatment facilities is discouraged despite the lack of data. The purpose of this review is to describe the outcomes of fractures that were internally fixed in the combat environment. The records of patients who had internal fixation performed in the theater of combat operations were reviewed. Demographics, injury characteristics, procedure history, and outcomes were recorded and analyzed. Forty-seven patients had internal fixation performed on 50 fractures in a combat theater hospital. Hip, forearm, and ankle fractures made up the majority of cases with 14 (28%), 14 (28%), and 10 (20%), respectively. Sixteen (32%) fractures were open. The average Injury Severity Score was 11.4 +/- 1.1 (range, 4-34). Thirty-nine fractures (78%) healed without incidence. There was one (2%) infection and one (2%) acute surgical complication. Ten (20%) fractures, including the one infection, required additional procedures. Because internal fixation in the combat environment was used judiciously, complications were not higher than previously reported.
Rajan, Prashant V; Qudsi, Rameez A; Dyer, George S M; Losina, Elena
2018-02-07
There is no consensus on the optimal fixation method for patients who require a surgical procedure for distal radial fractures. We used cost-effectiveness analyses to determine which of 3 modalities offers the best value: closed reduction and percutaneous pinning, open reduction and internal fixation, or external fixation. We developed a Markov model that projected short-term and long-term health benefits and costs in patients undergoing a surgical procedure for a distal radial fracture. Simulations began at the patient age of 50 years and were run over the patient's lifetime. The analysis was conducted from health-care payer and societal perspectives. We estimated transition probabilities and quality-of-life values from the literature and determined costs from Medicare reimbursement schedules in 2016 U.S. dollars. Suboptimal postoperative outcomes were determined by rates of reduction loss (4% for closed reduction and percutaneous pinning, 1% for open reduction and internal fixation, and 11% for external fixation) and rates of orthopaedic complications. Procedural costs were $7,638 for closed reduction and percutaneous pinning, $10,170 for open reduction and internal fixation, and $9,886 for external fixation. Outputs were total costs and quality-adjusted life-years (QALYs), discounted at 3% per year. We considered willingness-to-pay thresholds of $50,000 and $100,000. We conducted deterministic and probabilistic sensitivity analyses to evaluate the impact of data uncertainty. From the health-care payer perspective, closed reduction and percutaneous pinning dominated (i.e., produced greater QALYs at lower costs than) open reduction and internal fixation and dominated external fixation. From the societal perspective, the incremental cost-effectiveness ratio for closed reduction and percutaneous pinning compared with open reduction and internal fixation was $21,058 per QALY and external fixation was dominated. In probabilistic sensitivity analysis, open reduction and internal fixation was cost-effective roughly 50% of the time compared with roughly 45% for closed reduction and percutaneous pinning. When considering data uncertainty, there is only a 5% to 10% difference in the frequency of probability combinations that find open reduction and internal fixation to be more cost-effective. The current degree of uncertainty in the data produces difficulty in distinguishing either strategy as being more cost-effective overall and thus it may be left to surgeon and patient shared decision-making. Economic Level III. See Instructions for Authors for a complete description of levels of evidence.
Proffit, William R; Turvey, Timothy A; Phillips, Ceib
2007-04-30
A hierarchy of stability exists among the types of surgical movements that are possible with orthognathic surgery. This report updates the hierarchy, focusing on comparison of the stability of procedures when rigid fixation is used. Two procedures not previously placed in the hierarchy now are included: correction of asymmetry is stable with rigid fixation and repositioning of the chin also is very stable. During the first post-surgical year, surgical movements in patients treated for Class II/long face problems tend to be more stable than those treated for Class III problems. Clinically relevant changes (more than 2 mm) occur in a surprisingly large percentage of orthognathic surgery patients from one to five years post-treatment, after surgical healing is complete. During the first post-surgical year, patients treated for Class II/long face problems are more stable than those treated for Class III problems; from one to five years post-treatment, some patients in both groups experience skeletal change, but the Class III patients then are more stable than the Class II/long face patients. Fewer patients exhibit long-term changes in the dental occlusion than skeletal changes, because the dentition usually adapts to the skeletal change.
Methanotrophy induces nitrogen fixation during peatland development
Larmola, Tuula; Leppänen, Sanna M.; Tuittila, Eeva-Stiina; Aarva, Maija; Merilä, Päivi; Fritze, Hannu; Tiirola, Marja
2014-01-01
Nitrogen (N) accumulation rates in peatland ecosystems indicate significant biological atmospheric N2 fixation associated with Sphagnum mosses. Here, we show that the linkage between methanotrophic carbon cycling and N2 fixation may constitute an important mechanism in the rapid accumulation of N during the primary succession of peatlands. In our experimental stable isotope enrichment study, previously overlooked methane-induced N2 fixation explained more than one-third of the new N input in the younger peatland stages, where the highest N2 fixation rates and highest methane oxidation activities co-occurred in the water-submerged moss vegetation. PMID:24379382
Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Marx, Frank; Koller, Heiko; Kolb, Klaus
2010-09-01
The complication rate of periprosthetic femoral fractures above well-fixed total knee arthroplasties is high. The Less Invasive Stabilization System (LISS) was introduced to reduce surgical dissections at the fracture site. The purpose of this retrospective study was to evaluate the midterm functional outcome of a group of patients with periprosthetic fractures above well-fixed total knee arthroplasties treated with the LISS. Between January 1999 and June 2004, 23 consecutive patients (all women) with periprosthetic fractures above well-fixed total knee arthroplasties were treated with the LISS. The mean age was 77 years (range, 61-90 years). Nineteen of the patients (83%) were seen after a midterm follow-up of 46 months (range, 26-67 months). Three patients (13%) died, and one patient (4%) was lost to follow-up. A proximal screw pull-out of the internal fixator occurred in one patient (4%). All fractures healed within a mean of 14 weeks (range, 9-21 weeks). No bone graft was required. There were two delayed unions, no nonunions or infections. One patient (4%) had a malalignment with 7° varus. The mean range of motion was 102° (range, 65-120°). The mean knee score of the Knee Society was 81 points (range, 65-90 points), and the mean function score of the Knee Society was 56 points (range, 35-90 points). We found that a minimally invasive, locked plating system permitted stable fixation, early knee motion with good midterm results, and minimal complications. These techniques should be used in place of less stable and more invasive methods.
Use of Resorbable Fixation System in Pediatric Facial Fractures.
Wong, Frankie K; Adams, Saleigh; Hudson, Donald A; Ozaki, Wayne
2017-05-01
Resorbable fixation system (RFS) is an alternative to titanium in open reduction and internal fixation of pediatric facial fractures. This study retrospectively reviewed all medical records in a major metropolitan pediatric hospital in Cape Town, South Africa from September 2010 through May 2014. Inclusion criteria were children under the age of 13 with facial fractures who have undergone open reduction and internal fixation using RFS. Intraoperative and postoperative complications were reviewed. A total of 21 patients were included in this study. Twelve were males and 9 were females. Good dental occlusion was achieved in all patients and there were no complications intraoperatively. Three patients developed postoperative implanted-related complications: all 3 patients developed malocclusions and 1 developed an additional sterile abscess over the right zygomatic bone. For the latter, incision and drainage was performed and the problem resolved without additional operations. Resorbable fixation system is an alternative to titanium products in the setting of pediatric facial fractures without complications involving delayed union or malunion. The combination of intermaxillary fixation and RFS is not needed postoperatively for adequate fixation of mandible fractures. Resorbable fixation system is able to provide adequate internal fixation when both low-stress and high-stress craniofacial fractures occur simultaneously.
Free flap reconstructions of tibial fractures complicated after internal fixation.
Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S
1995-04-01
The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.
Outcome of distal end clavicle fractures treated with locking plates.
Vaishya, Raju; Vijay, Vipul; Khanna, Vikram
2017-02-01
Fractures of the lateral end of the clavicle are relatively uncommon. These fractures are unstable due to the various deforming forces which act on the fragments as well as the small distal fracture fragment. At most times the deforming forces are not taken into consideration, and the fracture is not fixed securely. In this study, we assessed a fixation technique using the precontoured locking plates to find out whether it provided a stable fixation with good functional outcome. Totally, 32 patients with lateral end clavicle fracture (Neer's Type II) were included in the study. After the informed consent and preoperative investigations were obtained, open reduction and internal fixation was done using a 3.5 mm precontoured superior locking plate with lateral extension under general anesthesia. Postoperative X-rays were done on day 1 and every 6 weeks after operation, until radiological union was achieved. The postoperative pain was assessed using Visual Analogue Scale (VAS) on postoperative days 1, 2 and 10. Postoperatively arm pouch sling was given for 2 weeks followed by active mobilization. Patients were asked to do their daily routine work and avoid lifting heavy weights. The functional outcome was assessed at the end of 2nd and 6th months with the help of Disabilities of the Arm, Shoulder and Hand (DASH) scoring. There were no intraoperative complications in the procedure. The mean VAS score on postoperative day 1 was found to be 5 which decreased to 3 on day 2 and 0 on day 10. The mean DASH score was calculated as 11.63 at the end of postoperative month 2 and then 4.6 at the end of month 6. There was one case of malunion in whom the overhead abduction was restricted but was not painful and was managed conservatively. The precontoured locking plates with lateral extension may be a good method to fix the fractures of the lateral end clavicle, which provide a stable fixation with good functional outcome with very few instances of stiffness and decreased range of motion of the shoulder with the hook plates and failure of fixation in screw and K-wire fixations. It may well be the answer to the fixation questions of the lateral clavicle fractures, although larger comparative studies between the surgical treatment methods are required to confirm the same. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.
Choi, Sungwook; Kim, Sang-Rim; Kang, Hyunseong; Kim, Donghee; Park, Yong-Geun
2015-02-01
The purpose of this study was to report a new surgical technique for the treatment of unstable distal clavicle fracture with modified tension band fixation (MTBF) and coracoclavicular (CC) stabilisation, and evaluate the radiologic and clinical outcome of these patients. Thirteen patients who had a fracture of the distal clavicle (Neer classification type IIb) were treated with MTBF and CC stabilisation. After the CC stabilisation was performed with a suture anchor or flip button, internal fixation using MTBF was carried out. Each patient was followed up for a minimum of 12 months and their clinical and radiological results were analysed. The mean period required for fracture union was 12.6 (range, 8-24) weeks and union was successfully completed in all cases. The mean Constant score at the final follow-up was 94.7 (88-100); the modified University of California, Los Angeles (UCLA) shoulder rating scale was 31.3 points (range, 22-35). All patients returned to normal daily activities at an average of 3.7 months postoperatively (range, 3-5 months). One patient had a new fracture around drilled holes for CC stabilisation by inappropriate tunnelling. MTBF and CC stabilisation is a useful technique for treating an unstable distal clavicle fracture. This procedure provides minimal incision and stable fixation without causing any further acromioclavicular joint injury to those with distal clavicle fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.
Outcomes of Internal Fixation in a Combat Environment
2010-01-01
analyzed. Forty-seven patients had internal fixation performed on 50 fractures in a combat theater hospital. Hip, forearm, and ankle fractures made up the...limited number of fracture patterns associated with a significant risk of failure if definitive treatment is delayed (4). Because of the limited...Injuries Hip, forearm, and ankle fractures made up the majority of internal fixation cases with 14 (28%), 14 (28%), and 10 TABLE 1 Mechanism of
Wardle, B; Eslick, G D; Sunner, P
2016-10-01
Improving reduction of the pelvic ring improves long-term functional outcomes for patients. It has been demonstrated that posterior internal fixation is necessary to adequately control fractures to the posterior ring and there is evidence that supplementing this with fixation of the anterior ring improves stability. It is accepted that internal fixation provides greater stability than external fixation of the anterior ring but long-term differences in radiographic and functional outcomes have not yet been quantified. A search of electronic databases, reference lists and review articles from 1989 to 2015 yielded 18 studies (n = 884) that met our inclusion criteria. We included studies that discussed pelvic ring injuries in adults, reported functional or radiological outcomes or complications by anterior ring intervention and exceeded 14 patients. We excluded biomechanical and cadaver studies. Internal fixation of the anterior pelvic ring had better functional and radiographic outcomes. Residual displacement of >10 mm was less common with internal fixation (ER 0.12, 95 % CI 0.06-0.24) than external fixation (ER 0.31, 95 % CI 0.11-0.62). Unsatisfactory outcomes also occurred at a lower rate (ER 0.09, 95 % CI 0.03-0.22) compared to external fixation (ER 0.32, 95 % CI 0.18-0.50). Losses of reduction (ER 0.02, 95 % CI 0.01-0.04 versus ER 0.07, 95 % CI 0.02-0.21), malunions (ER 0.03, 95 % CI 0.01-0.08 versus ER 0.07, 95 % CI 0.02-0.21) and delayed/non-unions (ER 0.02, 95 % CI 0.01-0.05 versus ER 0.04, 95 % CI 0.02-0.07). Internal fixation of the anterior pelvic ring as supplementary fixation for unstable injuries to the pelvic ring appears to result in better radiographic and functional outcomes as well as fewer complications. However, data that separated outcomes and complications in relation to interventions of the anterior pelvic ring were limited. More studies looking specifically at outcomes in relation to the type of anterior ring intervention are needed.
Pan, M; Chai, L; Xue, F; Ding, L; Tang, G; Lv, B
2017-07-01
The aim of this study was to compare the biomechanical stability and clinical outcome of external fixator combined with limited internal fixation (EFLIF) and open reduction and internal fixation (ORIF) in treating Sanders type 2 calcaneal fractures. Two types of fixation systems were selected for finite element analysis and a dual cohort study. Two fixation systems were simulated to fix the fracture in a finite element model. The relative displacement and stress distribution were analysed and compared. A total of 71 consecutive patients with closed Sanders type 2 calcaneal fractures were enrolled and divided into two groups according to the treatment to which they chose: the EFLIF group and the ORIF group. The radiological and clinical outcomes were evaluated and compared. The relative displacement of the EFLIF was less than that of the plate (0.1363 mm to 0.1808 mm). The highest von Mises stress value on the plate was 33% higher than that on the EFLIF. A normal restoration of the Böhler angle was achieved in both groups. No significant difference was found in the clinical outcome on the American Orthopedic Foot and Ankle Society Ankle Hindfoot Scale, or on the Visual Analogue Scale between the two groups (p > 0.05). Wound complications were more common in those who were treated with ORIF (p = 0.028). Both EFLIF and ORIF systems were tested to 160 N without failure, showing the new construct to be mechanically safe to use. Both EFLIF and ORIF could be effective in treating Sanders type 2 calcaneal fractures. The EFLIF may be superior to ORIF in achieving biomechanical stability and less blood loss, shorter surgical time and hospital stay, and fewer wound complications. Cite this article : M. Pan, L. Chai, F. Xue, L. Ding, G. Tang, B. Lv. Comparisons of external fixator combined with limited internal fixation and open reduction and internal fixation for Sanders type 2 calcaneal fractures: Finite element analysis and clinical outcome. Bone Joint Res 2017;6:433-438. DOI: 10.1302/2046-3758.67.2000640. © 2017 Xue et al.
2010-01-01
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67,1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AO-FAS-Score and radiographs. 92,7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63,7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection. PMID:20452884
Kienast, Benjamin; Kiene, J; Gille, J; Thietje, R; Gerlach, U; Schulz, A P
2010-02-26
Although there is a clear trend toward internal fixation for ankle arthrodesis, there is general consensus that external fixation is required for cases of posttraumatic infection. We retrospectively evaluated the technique and clinical long term results of external fixation in a triangular frame for cases of posttraumatic infection of the ankle. From 1993 to 2006 a consecutive series of 155 patients with an infection of the ankle was included in our study. 133 cases of the advanced "Gächter" stage III and IV were treated with arthrodesis. We treated the patients with a two step treatment plan. After radical debridement and sequestrectomy the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted in the tibia and in the calcaneus and the gap was temporary filled with gentamicin beads as the first step. In the second step we performed an autologous bone graft after a period of four weeks. The case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues. Mean age at the index procedure was 49.7 years (18-82), 104 patients were male (67.1%). Follow up examination after mean 4.5 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. 92.7% of the cases lead to a stable arthrodesis. In 5 patients the arthrodesis was found partly-stable. In six patients (4,5%) the infection was not controllable during the treatment process. These patients had to be treated with a below knee amputation. The mean AOFAS score at follow up was 63.7 (53-92). Overall there is a high degree of remaining disability. The complication rate and the reduced patient comfort reserve this method mainly for infection. Joint salvage is possible in the majority of cases with an earlier stage I and II infection.
Chen, Fang-Hu; Zhao, Xiao-Ping; Zheng, Wen-Biao; Zeng, Han-Bing; Ran, Bo; Huang, Hui; Wang, Hai-Bao
2013-05-01
To observe the clinical therapeutic effects of sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation. From June 2010 to June 2012, 7 patients with sternoclavicular joint dislocation were treated with sternoclavicular hook plate fixation. Among the 7 patients, 5 patients were male and 2 patients were female, and the average age was 42.3 years, ranging from 38 to 54 years. The course of the disease ranged from 1 to 4 weeks. All the patients had trauma history. The clinical manifestations included: obvious swelling and pain of sternoclavicular joint, restricted shoulder joint activity. The sternoclavicular joint dislocation was proved by preoperative X-ray and CT. The postoperative curative effect was evaluated according to Rockwood scoring method. According to Rockwood scoring method, the excellent results obtained in 6 cases, good in 1. There were no complications such as internal fixation loosening or broken, second dislocation, pain in the sternoclavicular joint, and deformity. The function of shoulder joint was good, and the limb activity was free and no pain appeared. The sternoclavicular hook plate for the treatment of sternoclavicular joint dislocation has follow advantages: simple procedure, stable fixation, definite therapeutic effects.
Complex ankle arthrodesis: Review of the literature
Rabinovich, Remy V; Haleem, Amgad M; Rozbruch, S Robert
2015-01-01
Complex ankle arthrodesis is defined as an ankle fusion that is at high risk of delayed and nonunion secondary to patient comorbidities and/or local ankle/hindfoot factors. Risk factors that contribute to defining this group of patients can be divided into systemic factors and local factors pertaining to co-existing ankle or hindfoot pathology. Orthopaedic surgeons should be aware of these risk factors and their association with patients’ outcomes after complex ankle fusions. Both external and internal fixations have demonstrated positive outcomes with regards to achieving stable fixation and minimizing infection. Recent innovations in the application of biophysical agents and devices have shown promising results as adjuncts for healing. Both osteoconductive and osteoinductive agents have been effectively utilized as biological adjuncts for bone healing with low complication rates. Devices such as pulsed electromagnetic field bone stimulators, internal direct current stimulators and low-intensity pulsed ultrasound bone stimulators have been associated with faster bone healing and improved outcomes scores when compared with controls. The aim of this review article is to present a comprehensive approach to the management of complex ankle fusions, including the use of biophysical adjuncts for healing and a proposed algorithm for their treatment. PMID:26396936
Proffit, William R; Turvey, Timothy A; Phillips, Ceib
2007-01-01
A hierarchy of stability exists among the types of surgical movements that are possible with orthognathic surgery. This report updates the hierarchy, focusing on comparison of the stability of procedures when rigid fixation is used. Two procedures not previously placed in the hierarchy now are included: correction of asymmetry is stable with rigid fixation and repositioning of the chin also is very stable. During the first post-surgical year, surgical movements in patients treated for Class II/long face problems tend to be more stable than those treated for Class III problems. Clinically relevant changes (more than 2 mm) occur in a surprisingly large percentage of orthognathic surgery patients from one to five years post-treatment, after surgical healing is complete. During the first post-surgical year, patients treated for Class II/long face problems are more stable than those treated for Class III problems; from one to five years post-treatment, some patients in both groups experience skeletal change, but the Class III patients then are more stable than the Class II/long face patients. Fewer patients exhibit long-term changes in the dental occlusion than skeletal changes, because the dentition usually adapts to the skeletal change. PMID:17470277
Yang, Mingjie; Sun, Guixin; Guo, Song; Zeng, Cheng; Yan, Meijun; Han, Yingchao; Xia, Dongdong; Zhang, Jingjie; Li, Xinhua; Xiang, Yang; Pan, Jie; Li, Lijun; Tan, Jun
2017-01-01
Finite-element method was used to evaluate biomechanics stability of extraforaminal lumbar interbody fusion (ELIF) under different internal fixation. The L3-L5 level finite-element model was established to simulate decompression and internal fixation at L4-L5 segment. The intact finite model was treated in accordance with the different internal fixation. The treatment groups were exerted 400 N load and 6 N·m additional force from motion to calculate the angular displacement of L4-L5. The ROMs were smaller in all internal fixation groups than those in the intact model. Furthermore, the ROMs were smaller in ELIF + UPS group than in TLIF + UPS group under all operating conditions, especially left lateral flexion and right rotation. The ROMs were higher in ELIF + UPS group than in TLIF + BPS group. The ROMs of ELIF + UPS + TLFS group were much smaller than those in ELIF + UPS group, and as compared with TLIF + BPS group, there was no significant difference in the range of experimental loading. The biomechanical stability of ELIF with unilateral pedicle screw fixation is superior to that of TLIF with unilateral pedicle screw fixation but lower than that of TLIF with bilateral pedicle screws fixation. The stability of ELIF with unilateral fixation can be further improved by supplementing a translaminar facet screw.
Wu, Tao; Ren, Xuejiao; Cui, Yunwei; Cheng, Xiaodong; Peng, Shuo; Hou, Zhiyong; Han, Yongtai
2018-06-19
To compare the stability of sacroiliac joint disruption fixed with three kinds of internal fixation using both biomechanical test and finite element analysis. Five embalmed specimens of an adult were used. The symphysis pubis rupture and left sacroiliac joint disruption were created. The symphysis pubis was stabilized with a five-hole plate. The sacroiliac joint disruption was fixed with three kinds of internal fixation in a randomized design. Displacements of the whole specimen and shifts in the gap were recorded. Three-dimensional finite element models of the pelvis, the pelvis with symphysis pubis rupture and left sacroiliac joint disruption, and three kinds of internal fixation techniques were created and analyzed. Under the vertical load, the displacements and shifts in the gap of the pelvis fixed with minimally invasive adjustable plate (MIAP) combined with one iliosacral (IS) screw were the smallest, and the average displacements of the pelvis fixed with an anterior plate were the largest one. The differences among them were significant. In finite element analysis and MIAP combined with one IS screw fixation showed relatively best fixation stability and lowest risks of implant failure than two IS screws fixation and anterior plate fixation. The stability of sacroiliac joint disruption fixed with MIAP combined with one IS screw is better than that fixed with two IS screws and anterior plate under vertical load.
Novel Anterior Plating Technique for Patella Fracture Fixation.
Siljander, Matthew P; Vara, Alexander D; Koueiter, Denise M; Wiater, Brett P; Wiater, Patrick J
2017-07-01
Patella fracture fixation remains a significant challenge for orthopedic surgeons. Although tension band fixation allows for reliable osseous union, especially in simple fracture patterns, it still presents several problems. Plate fixation of patella fractures is a method that allows for more rigid stabilization and earlier mobilization. At the authors' level 1 trauma center, one fellowship-trained trauma surgeon has transitioned to using a novel anterior, low-profile mesh plate construct for all types of patella fractures. This construct allows for stable fixation, osseous union, and neutralization of the inferior pole for even the most comminuted of patella fractures. [Orthopedics. 2017; 40(4):e739-e743.]. Copyright 2017, SLACK Incorporated.
[The biomechanics of screws, cerclage wire and cerclage cable].
Schröder, C; Woiczinski, M; Utzschneider, S; Kraxenberger, M; Weber, P; Jansson, V
2013-05-01
In contrast to fracture fixation, when performing an osteotomy the surgeon is able to plan preoperatively. The resulting fixation and compression of the bone fragments are the most important points. A stable osteosynthesis should prevent dislocation of bone fragments and improve bone healing. Beside plates, cerclages can be used for tension band or diaphysis bone fixation. Moreover, cortical or cancellous screws can be used for osteotomy fixation. This work describes biomechanical principles for fixation after an osteotomy with cerclages and cortical or cancellous screws. It also summarizes the materials and geometries used, as well as their influence on the stability of the osteosynthesis.
Salden, O A E; van Everdingen, W M; Spee, R; Doevendans, P A; Cramer, M J
2018-03-27
Stress echocardiography (SE) has recently regained momentum as an important diagnostic tool for the assessment of both ischemic and non-ischemic heart disease. Performing SE during physical exercise is challenging due to a suboptimal patient position and vigorous movements of the patient's chest. This hampers a stable ultrasound position and reduces the diagnostic performance of SE. A stable ultrasound probe position would facilitate producing high quality images during continuous measurements. With Probefix (Usono, Eindhoven, The Netherlands), a newly developed tool to fixate the ultrasound probe to the patient's chest, stabilization of the probe during physical exercise is possible. The technique of SE with the Probefix and its' feasibility are evaluated in a small pilot study. Probefix fixates the ultrasound probe to the patient's chest, using two chest straps and a fixation device. The ultrasound probe position and angle may be altered with a relative high degree of freedom. We tested the Probefix for continuous echocardiographic imaging in 12 study subjects during supine and upright ergometer stress tests. One patient was unable to perform exercise and in two study subjects good quality images were not achieved. In the other patients (82%) a stable probe position was obtained, with subsequent good quality echocardiographic images during SE. We have demonstrated the feasibility of the Probefix support during ergometer tests in supine and upright positions and conclude that this external fixator may facilitate continuous monitoring of cardiac function in a group of patients.
An Overview of Internal and External Fixation Methods for the Diabetic Charcot Foot and Ankle.
Ramanujam, Crystal L; Zgonis, Thomas
2017-01-01
Diabetic Charcot neuroarthropathy (DCN) of the foot and ankle is a challenging disease with regard to clinical presentation, pathogenesis, and prognosis. Its surgical management is equally difficult to interpret based on the wide array of options available. In the presence of an ulceration or concomitant osteomyelitis, internal fixation by means of screws, plates, or intramedullary nailing needs to be avoided when feasible. External fixation becomes a great surgical tool when managing DCN with concomitant osteomyelitis. This article describes internal and external fixation methods along with available literature to enlighten surgeons faced with treating this complex condition. Copyright © 2016 Elsevier Inc. All rights reserved.
Waaler Bjørnelv, G M; Frihagen, F; Madsen, J E; Nordsletten, L; Aas, E
2012-06-01
We estimated the cost-effectiveness of hemiarthroplasty compared to internal fixation for elderly patients with displaced femoral neck fractures. Over 2 years, patients treated with hemiarthroplasty gained more quality-adjusted life years than patients treated with internal fixation. In addition, costs for hemiarthroplasty were lower. Hemiarthroplasty was thus cost effective. Estimating the cost utility of hemiarthroplasty compared to internal fixation in the treatment of displaced femoral neck fractures in the elderly. A cost-utility analysis (CUA) was conducted alongside a clinical randomized controlled trial at a university hospital in Norway; 166 patients, 124 (75%) women with a mean age of 82 years were randomized to either internal fixation (n = 86) or hemiarthroplasty (n = 80). Patients were followed up at 4, 12, and 24 months. Health-related quality of life was assessed with the EQ-5D, and in combination with time used to calculate patients' quality-adjusted life years (QALYs). Resource use was identified, quantified, and valued for direct and indirect hospital costs and for societal costs. Results were expressed in incremental cost-effectiveness ratios. Over the 2-year period, patients treated with hemiarthroplasty gained 0.15-0.20 more QALYs than patients treated with internal fixation. For the hemiarthroplasty group, the direct hospital costs, total hospital costs, and total costs were non-significantly less costly compared with the internal fixation group, with an incremental cost of €2,731 (p = 0.81), €2,474 (p = 0.80), and €14,160 (p = 0.07), respectively. Thus, hemiarthroplasty was the dominant treatment. Sensitivity analyses by bootstrapping supported these findings. Hemiarthroplasty was a cost-effective treatment. Trial registration, NCT00464230.
Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M
2014-12-01
To determine patient independency, health-related and disease-specific quality of life (QOL), gait pattern, and muscle strength in patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture. Secondary cohort study to a randomized controlled trial. Multicenter trial in the Netherlands, including 14 academic and nonacademic hospitals. Patients after salvage arthroplasty for failed internal fixation of a femoral neck fracture were studied. A comparison was made with patients who healed uneventfully after internal fixation. None (observatory study). Patient characteristics, SF-12, and Western Ontario McMaster osteoarthritis index scores were collected. Gait parameters were measured using plantar pressure measurement. Maximum isometric forces of the hip muscles were measured using a handheld dynamometer. Differences between the fractured and contralateral leg were calculated. Groups were compared using univariate analysis. Of 248 internal fixation patients (median age, 72 years), salvage arthroplasty was performed in 68 patients (27%). Salvage arthroplasty patients had a significantly lower Western Ontario McMaster osteoarthritis index score (median, 73 vs. 90; P = 0.016) than patients who healed uneventfully after internal fixation. Health-related QOL (SF-12) and patient independency did not differ significantly between the groups. Gait analysis showed a significantly impaired progression of the center of pressure in the salvage surgery patients (median ratio, -8.9 vs. 0.4, P = 0.013) and a significant greater loss of abduction strength (median, -25.4 vs. -20.4 N, P = 0.025). Despite a similar level of dependency and QOL, salvage arthroplasty patients have inferior functional outcome than patients who heal after internal fixation of a femoral neck fracture. Therapeutic level III.
Spross, Christian; Zeledon, Rebeca; Zdravkovic, Vilijam; Jost, Bernhard
2017-09-01
With the introduction of the deltoid tuberosity index (DTI), a simple radiographic tool has become available to measure bone mineral density of the proximal humerus. The aim of this study was to assess the influence of local bone mineral density on the early failure rate after angular stable open reduction-internal fixation of proximal humeral fractures (PHFs). We retrospectively followed up all patients treated with angular stable implants for PHFs from 2007 to 2014. The fractures were classified according to Neer, and the DTI, metaphyseal head extension (MHE), medial hinge displacement, and quality of reduction were assessed. Failures were defined as head screw cutouts. The study included 146 patients (mean age, 66 years; range, 20-94 years). The mean follow-up period was 11 months (range, 3-94 months). Of the fractures, 91% were classified as 2- or 3-part fractures and 9% as 4-part fractures. The mean DTI was 1.44 (range, 1.19-2.11), and the mean MHE was 12 mm (range, 0-48 mm). The reduction result was at least acceptable in 80% of fractures. Screw cutouts were found in 23%. The DTI and MHE were the most significant preoperative predictors for the reduction result. The DTI (P = .036) and age (P = .02) were independent preoperative factors, and a good reduction (P = .001) was the only intraoperative factor influencing cutout. This study proves that good bone quality and a long MHE are helpful for the reduction. Furthermore, good bone quality, a younger age, and a good reduction prevent later cutout. We conclude that local bone quality is a relevant factor in the treatment plan for PHFs. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao
2017-01-01
Abstract The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation. Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups. The mean follow-up time was 18.6 months (range: 5–24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5–9 months) and 6.0 months (range: 5–8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°–150°) and 135° (range: 100°–160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05). External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation. PMID:29019890
Tao, Xingguang; Chen, Nong; Pan, Fugen; Cheng, Biao
2017-10-01
The aim of this study was to evaluate the clinical efficacy of external fixation, delayed open reduction, and internal fixation in treating tibial plateau fracture with dislocation.Clinical data of 34 patients diagnosed with tibial plateau fracture complicated with dislocation between January 2009 and May 2015 were retrospectively analyzed. Fifteen patients in group A underwent early calcaneus traction combined with open reduction and internal fixation and 19 in group B received early external fixation combined with delayed open reduction and internal fixation. Operation time, postoperative complication, bone healing time, knee joint range of motion, initial weight-bearing time, Rasmussen tibial plateau score, and knee function score (HSS) were statistically compared between 2 groups.The mean follow-up time was 18.6 months (range: 5-24 months). The mean operation time in group A was 96 minutes, significantly longer than 71 minutes in group B (P < .05). In group A, 5 cases had postoperative complications and 1 in group B (P < .05). The mean bone healing time in group A was 6.9 months (range: 5-9 months) and 6.0 months (range: 5-8 months) in group B (P > .05). In group A, initial weight-bearing time in group A was (14.0 ± 3.6) weeks, significantly differing from (12.9 ± 2.8) weeks in group B (P < 0.05). In group A, the mean knee joint range of motion was 122° (range: 95°-150°) and 135° (range: 100°-160°) in group B (P > 0.05). Rasmussen tibial plateau score in group A was slightly lower than that in group B (P > .05). The excellent rate of knee joint function in group A was 80% and 84.21% in group B (P > .05).External fixation combined with delayed open reduction and internal fixation is a safer and more efficacious therapy of tibial plateau fracture complicated with dislocation compared with early calcaneus traction and open reduction and internal fixation.
Emara, Khaled; El Moatasem, El Hussein; El Shazly, Ossama
2011-12-01
Complex foot deformity is a multi-planar foot deformity with many etiologic factors. Different corrective procedures using Ilizarov external fixation have been described which include, soft tissue release, V-osteotomy, multiple osteotomies and triple fusion. In this study we compare the results of two groups of skeletally mature patients with complex foot deformity who were treated by two different protocols. The first group (27 patients, 29 feet) was treated by triple fusion fixed by Ilizarov external fixator until union. The second group (29 patients, 30 feet), was treated by triple fusion with initial fixation by Ilizarov external fixation until correction of the deformity was achieved clinically, and then the Ilizarov fixation was replaced by internal fixation using percutaneous screws. Both groups were compared as regard the surgical outcome and the incidence of complications. There was statistically significant difference between the two groups regarding duration of external fixation and duration of casting with shorter duration in the group 2. Also there was statistically significant difference between both groups regarding pin tract infection with less incidence in group 2. Early removal of Ilizarov external fixation after correction of the deformity and percutaneous internal fixation using 6.5 cannulated screws can shorten the duration of treatment and be more comfortable for the patient with a low risk of recurrence or infection. Copyright © 2010 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Tonetti, J
2013-02-01
Traumatic injury to the pelvic ring is a result of high energy trauma in young patients. These osteo-ligamentous injuries are associated with numerous lesions including retroperitoneal hematoma, urogenital, cutaneous and neurological (lumbosacral plexus). The goal of initial management is to restore vital indicators, urinary excretion function and protect the patient from infectious complications. An emergency decisional algorithm helps manage haemodynamic instability. Initial bone and ligament procedures should reduce displacement and make it possible for the patient the wait until his condition is stable enough for definitive surgical fixation. The goal of surgical treatment is to avoid nonunion and malunion. Stable fixation of the posterior arch after reduction favors union. Different techniques can be used by the posterior, anterior ilio-inguinal or lateral percutaneous approaches. Anterior fixation is discussed to improve reduction and increase the stability obtained with a posterior procedure. Anterior external fixation is useful to temporarily reinforce posterior stabilization. Copyright © 2013. Published by Elsevier Masson SAS.
Mcdonald, E; Theologis, A A; Horst, P; Kandemir, U; Pekmezci, M
2015-12-01
This study aimed at evaluating the additional stability that is provided by anterior external and internal fixators in an unstable pelvic fracture model (OTA 61-C). An unstable pelvic fracture (OTA 61-C) was created in 27 synthetic pelves by making a 5-mm gap through the sacral foramina (posterior injury) and an ipsilateral pubic rami fracture (anterior injury). The posterior injury was fixed with either a single iliosacral (IS) screw, a single trans-iliac, trans-sacral (TS) screw, or two iliosacral screws (S1S2). Two anterior fixation techniques were utilized: external fixation (Ex-Fix) and supra-acetabular external fixation and internal fixation (In-Fix); supra-acetabular pedicle screws connected with a single subcutaneous spinal rod. The specimens were tested using a nondestructive single-leg stance model. Peak-to-peak (P2P) displacement and rotation and conditioning displacement (CD) were calculated. The Ex-Fix group failed in 83.3 % of specimens with concomitant single-level posterior fixation (Total: 15/18-7 of 9 IS fixation, 8 of 9 TS fixation), and 0 % (0/9) of specimens with concomitant two-level (S1S2) posterior fixation. All specimens with the In-Fix survived testing except for two specimens treated with In-Fix combined with IS fixation. Trans-sacral fixation had higher pubic rotation and greater sacral and pubic displacement than S1S2 (p < 0.05). Rotation of the pubis and sacrum was not different between In-Fix constructs combined with single-level IS and TS fixation. In this model of an unstable pelvic fracture (OTA 61-C), anterior fixation with an In-Fix was biomechanically superior to an anterior Ex-Fix in the setting of single-level posterior fixation. There was no biomechanical difference between the In-Fix and Ex-Fix when each was combined with two levels of posterior sacral fixation.
Tibial Plateau Fractures in Elderly Patients
Vemulapalli, Krishna C.; Gary, Joshua L.; Donegan, Derek J.
2016-01-01
Tibial plateau fractures are common in the elderly population following a low-energy mechanism. Initial evaluation includes an assessment of the soft tissues and surrounding ligaments. Most fractures involve articular depression leading to joint incongruity. Treatment of these fractures may be complicated by osteoporosis, osteoarthritis, and medical comorbidities. Optimal reconstruction should restore the mechanical axis, provide a stable construct for mobilization, and reestablish articular congruity. This is accomplished through a variety of internal or external fixation techniques or with acute arthroplasty. Regardless of the treatment modality, particular focus on preservation and maintenance of the soft tissue envelope is paramount. PMID:27551570
Biomechanical principles and mechanobiologic aspects of flexible and locked plating.
Claes, Lutz
2011-02-01
The goal of minimally invasive surgery in extramedullary internal fixation has led to the development of flexible plates, bridging plates, and locked internal fixators. The change from conventional compression plates to these new implants, however, resulted in different biomechanics of fixation and different mechanobiologic processes for fracture healing. The aim of a flexible fixation is the stimulation of fracture healing by callus formation. Fracture healing follows mechanobiologic rules based mainly on interfragmentary strain, which is dependent on the stability of the fixation construct and the type of fracture. Knowledge of the mechanobiologic processes and the factors influencing the stability of fracture fixation are necessary for the surgeon to choose the correct technique for fracture fixation. Problems in the selection of the correct technique and limitations with the available implants as well as possible future developments are discussed.
Baker, Stephen B; Reid, Russell R; Burkey, Brooke; Bartlett, Scott P
2007-09-01
To shorten head frame wear time associated with external halo distraction (HD), we have adapted a protocol for maxillary distraction with the halo system that integrates plate fixation. All patients had a history of cleft lip and/or palate and maxillary retrusion > or = 8 mm. Five patients treated with this protocol and followed for at least 1 year were included in this study. The protocol included a 3-day latency period, variable maxillary distraction, and removal of the halo device with simultaneous rigid internal fixation. Two patients had a variable period of maxillomandibular fixation (MMF), which maintained the maxillary advancement and idealized intercuspal position while permitting further callus maturation. Cephalographs were obtained preoperatively, immediately following distractor removal, and 1 year after rigid internal fixation. The mean age at time of surgery was 18.7 years. The maxillary deficiency ranged from 8 to 15 mm (mean = 10.6 mm). All five patients demonstrated excellent occlusion. Cephalometric analysis 1-year post rigid internal fixation revealed minimal (<1 mm) skeletal relapse. Rapid maxillary distraction followed by MMF to maintain maxillary advancement may reduce halo device wear to 1 to 2 weeks. MMF optimizes occlusion by forcing the maxillary teeth into maximal intercuspal position. Rigid fixation is not only associated with less long-term relapse compared to nonrigid forms of fixation, but also minimizes the incidence of nonunion. This treatment protocol provides the advancement possible with distraction osteogenesis and the accuracy of orthognathic surgery, thereby minimizing external head frame wear.
First metatarsal-phalangeal joint arthrodesis: a biomechanical assessment of stability.
Politi, Joel; John, Hayes; Njus, Glen; Bennett, Gordon L; Kay, David B
2003-04-01
First metatarsal phalangeal joint (MTP) arthrodesis is a commonly performed procedure for the treatment of hallux rigidus, severe and recurrent bunion deformities, rheumatoid arthritis and other less common disorders of the joint. There are different techniques of fixation of the joint to promote arthrodesis including oblique lag screw fixation, lag screw and dorsal plate fixation, crossed Kirschner wires, dorsal plate fixation alone and various types of external fixation. Ideally the fixation method should be reproducible, lead to a high rate of fusion, and have a low incidence of complications. In the present study, we compared the strength of fixation of five commonly utilized techniques of first MTP joint arthrodesis. These were: 1. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical interfragmentary lag screw. 2. Surface excision with machined conical reaming and fixation with crossed 0.062 Kirschner wires. 3. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical lag screw and a four hole dorsal miniplate secured with 3.5 mm cortical screws. 4. Surface excision with machined conical reaming and fixation with a four hole dorsal miniplate secured with 3.5 mm cortical screws and no lag screw. 5. Planar surface excision and fixation with a single oblique 3.5 mm interfragmentary cortical lag screw. Testing was done on an Instron materials testing device loading the first MTP joint in dorsiflexion. Liquid metal strain gauges were placed over the joint and micromotion was detected with varying loads and cycles. The most stable technique was the combination of machined conical reaming and an oblique interfragmentary lag screw and dorsal plate. This was greater than two times stronger than an oblique lag screw alone. Dorsal plate alone and Kirschner wire fixation were the weakest techniques. First MTP fusion is a commonly performed procedure for the treatment of a variety of disorders of the first MTP joint. The most stable technique for obtaining fusion in this study was the combination of an oblique lag screw and a dorsal plate. This should lead to higher rates of arthrodesis.
Cui, Xueliang; Chen, Hui; Rui, Yunfeng; Niu, Yang; Li, He
2018-01-01
Objectives Two-stage open reduction and internal fixation (ORIF) and limited internal fixation combined with external fixation (LIFEF) are two widely used methods to treat Pilon injury. However, which method is superior to the other remains controversial. This meta-analysis was performed to quantitatively compare two-stage ORIF and LIFEF and clarify which method is better with respect to postoperative complications in the treatment of tibial Pilon fractures. Methods We conducted a meta-analysis to quantitatively compare the postoperative complications between two-stage ORIF and LIFEF. Eight studies involving 360 fractures in 359 patients were included in the meta-analysis. Results The two-stage ORIF group had a significantly lower risk of superficial infection, nonunion, and bone healing problems than the LIFEF group. However, no significant differences in deep infection, delayed union, malunion, arthritis symptoms, or chronic osteomyelitis were found between the two groups. Conclusion Two-stage ORIF was associated with a lower risk of postoperative complications with respect to superficial infection, nonunion, and bone healing problems than LIFEF for tibial Pilon fractures. Level of evidence 2.
A new adhesive technique for internal fixation in midfacial surgery
Endres, Kira; Marx, Rudolf; Tinschert, Joachim; Wirtz, Dieter Christian; Stoll, Christian; Riediger, Dieter; Smeets, Ralf
2008-01-01
Background The current surgical therapy of midfacial fractures involves internal fixation in which bone fragments are fixed in their anatomical positions with osteosynthesis plates and corresponding screws until bone healing is complete. This often causes new fractures to fragile bones while drilling pilot holes or trying to insert screws. The adhesive fixation of osteosynthesis plates using PMMA bone cement could offer a viable alternative for fixing the plates without screws. In order to achieve the adhesive bonding of bone cement to cortical bone in the viscerocranium, an amphiphilic bone bonding agent was created, analogous to the dentin bonding agents currently on the market. Methods The adhesive bonding strengths were measured using tension tests. For this, metal plates with 2.0 mm diameter screw holes were cemented with PMMA bone cement to cortical bovine bone samples from the femur diaphysis. The bone was conditioned with an amphiphilic bone bonding agent prior to cementing. The samples were stored for 1 to 42 days at 37 degrees C, either moist or completely submerged in an isotonic NaCl-solution, and then subjected to the tension tests. Results Without the bone bonding agent, the bonding strength was close to zero (0.2 MPa). Primary stability with bone bonding agent is considered to be at ca. 8 MPa. Moist storage over 42 days resulted in decreased adhesion forces of ca. 6 MPa. Wet storage resulted in relatively constant bonding strengths of ca. 8 MPa. Conclusion A new amphiphilic bone bonding agent was developed, which builds an optimizied interlayer between the hydrophilic bone surface and the hydrophobic PMMA bone cement and thus leads to adhesive bonding between them. Our in vitro investigations demonstrated the adhesive bonding of PMMA bone cement to cortical bone, which was also stable against hydrolysis. The newly developed adhesive fixing technique could be applied clinically when the fixation of osteosynthesis plates with screws is impossible. With the detected adhesion forces of ca. 6 to 8 MPa, it is assumed that the adhesive fixation system is able to secure bone fragments from the non-load bearing midfacial regions in their orthotopic positions until fracture consolidation is complete. PMID:18489785
Analysis of functional outcome of Hoffa fractures: A retrospective review of 32 patients.
Trikha, Vivek; Das, Saubhik; Gaba, Sahil; Agrawal, Prabhat
2017-01-01
Hoffa fractures are uncommon intra-articular fractures of femoral condyle in coronal plane. The purpose of our study is to assess radiologic and functional outcome in operatively treated Hoffa fractures. We retrospectively reviewed 32 patients of isolated Hoffa fracture from January 2010 to March 2015. All were treated with open reduction and internal fixation using lateral approach for lateral Hoffa and medial approach for medial Hoffa fracture. Cancellous screws in lag mode and/or antiglide plate were employed for fixation in accordance with fracture anatomy. All patients were subjected to aggressive physical therapy postoperatively. Knee Society Score (KSS), International Knee Documentation Committee Score (IKDC), and Knee range of motion (ROM) were documented at final follow-up for functional evaluation. All fractures united by mean time of 11.56 ± 1.5 weeks. No evidence of subsequent displacement or fixation failure, arthritis, Avascular necrosis (AVN) of femoral condyle was elicited in any of the patients. Documented mean KSS and mean IKDC Score at final follow-up were 83.19 ± 8.43 and 81.62± 6.95, respectively. ROM at final follow-up was ranging from 0° to mean 116.41° ± 13.98°. Complications included stiffness of the involved knee in four patients, including one patient who developed infection and had to undergo implant removal after fracture union. Operative treatment of Hoffa fractures yields fairly good functional outcome. One must endeavor to achieve adequate intraoperative exposure and stable congruous articular reconstruction. Early aggressive physical therapy is a harbinger of optimal outcome.
Shao, Jiashen; Chang, Hengrui; Zhu, Yanbin; Chen, Wei; Zheng, Zhanle; Zhang, Huixin; Zhang, Yingze
2017-05-01
This study aimed to quantitatively summarize the risk factors associated with surgical site infection after open reduction and internal fixation of tibial plateau fracture. Medline, Embase, CNKI, Wanfang database and Cochrane central database were searched for relevant original studies from database inception to October 2016. Eligible studies had to meet quality assessment criteria according to the Newcastle-Ottawa Scale, and had to evaluate the risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture. Stata 11.0 software was used for this meta-analysis. Eight studies involving 2214 cases of tibial plateau fracture treated by open reduction and internal fixation and 219 cases of surgical site infection were included in this meta-analysis. The following parameters were identified as significant risk factors for surgical site infection after open reduction and internal fixation of tibial plateau fracture (p < 0.05): open fracture (OR 3.78; 95% CI 2.71-5.27), compartment syndrome (OR 3.53; 95% CI 2.13-5.86), operative time (OR 2.15; 95% CI 1.53-3.02), tobacco use (OR 2.13; 95% CI 1.13-3.99), and external fixation (OR 2.07; 95% CI 1.05-4.09). Other factors, including male sex, were not identified as risk factors for surgical site infection. Patients with the abovementioned medical conditions are at risk of surgical site infection after open reduction and internal fixation of tibial plateau fracture. Surgeons should be cognizant of these risks and give relevant preoperative advice. Copyright © 2017. Published by Elsevier Ltd.
Shimamura, Yoshio; Kaneko, Kazuo; Kume, Kazuhiko; Maeda, Mutsuhiro; Iwase, Hideaki
2006-07-01
Previous studies have demonstrated the safe passive range of ankle motion for inter-bone stiffness after internal fixation under load but there is a lack of information about the safe range of ankle motion for early rehabilitation in the absence of loading. The present study was designed to assess the effect of ankle movement on inter-bone displacement characteristics of medial malleolus fractures following three types of internal fixation to determine the safe range of motion. Five lower legs obtained during autopsy were used to assess three types of internal fixation (two with Kirschner-wires alone; two with Kirschner-wires plus tension band wiring; and, one with an AO/ASIF malleolar screw alone). Following a simulated fracture by sawing through the medial malleolus the displacement between the fractured bone ends was measured during a passive range of movement with continuous monitoring using omega (Omega) shaped transducers and a biaxial flexible goniometer. Statistical analysis was performed with repeated measures analysis of variance. Inter-bone displacement was not proportional to the magnitude of movement throughout the range of ankle motion as, when separation exceeded 25 microm, there was increasingly wide separation as plantar-flexion or dorsal-flexion was increased. There was no statistical significant difference between the small amount of inter-bone displacement observed with three types of fixation within the safe range of dorsal-flexion and plantar-flexion for early rehabilitation. However the inter-bone separation when fixation utilized two Kirschner-wires alone tended to be greater than when using the other two types of fixation during dorsal-flexion and eversion. The present study revealed a reproducible range of ankle motion for early rehabilitation which was estimated to be within the range of 20 degrees of dorsal-flexion and 10 degrees of plantar-flexion without eversion. Also, internal fixation with two Kirschner-wires alone does not seem to provide stability achieved by the other two forms of fixation.
Distal femoral osteotomy in genovalgum: internal fixation with blade plate versus casting.
Makhmalbaf, Hadi; Moradi, Ali; Ganji, Saeid
2014-10-01
To compare the results of two different ways of distal femoral osteotomy stabilization in patients suffering from genuvalgum: internal fixation with plate, and casting. In a non-randomized prospective study, after distal femoral osteotomy with the zigzag method, patients were divided into two groups: long leg casting, and internal fixation with blade plate. For all patients, questionnaires were filled to obtain data. Information such as range of motion, tibiofemoral anatomical angle and complications were recorded. 38 knees with valgus deformity underwent distal femoral supracondylar osteotomy. (8 with plaster cast and 30 with internal fixation using a blade plate). Preoperative range of motion was 129±6° and six months later it was 120±14°. The preoperative tibiofemoral angle was 32±6°; postoperative tibiofemoral angles were 3±3°, 6±2°, and 7±3° just after operation, six months, and two years later, respectively. Although this angle was greater among the group stabilized with a cast, this difference was not statistically significant. In postoperative complications, over-correction was found in five, recorvatom deformity in one, knee stiffness in three and superficial wound infection was recorded in three knees. There is no prominent difference in final range of motion and alignment whether fixation is done with casting or internal fixation. However, the complication rate seems higher in the casting method.
Pan, Hao; Yu, Guangrong; Xiong, Wen; Zhao, Zhiming; Ding, Fan; Zheng, Qiong; Kan, Wushen
2011-07-01
To summarize the experience of treating old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone. Between May 2009 and July 2010, 7 patients with old metatarsal fractures were treated surgically, including 5 multi-metatarsal fractures and 2 single metatarsal fractures. There were 5 males and 2 females aged from 25 to 43 years (mean, 33 years). The time from fracture to operation was 4-12 weeks. The X-ray films showed that a small amount of callus formed at both broken ends with shortening, angulation, or rotation displacement. The surgical treatments included open reduction, internal fixation by miniplate, and autogenous iliac bone graft (1.5-2.5 cm(3)). The external plaster fixation was used in all patients for 4 to 6 weeks postoperatively (mean, 5 weeks). All incisions healed by first intention. The 7 patients were followed up 8-18 months (mean, 13.5 months). The clinical fracture healing time was 6 to 12 weeks postoperatively (mean, 8.4 weeks). No pain of planta pedis occurred while standing and walking. The American Orthopaedic Foot and Ankle Society (AOFAS) mesopedes and propodium score was 75-96 (mean, 86.4). It has the advantages of reliable internal fixation, high fracture healing rate, less complications to treat old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone graft, so it is an effective treatment method.
Christie, J; Howie, C R; Armour, P C
1988-03-01
One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.
Pediatric mandibular fractures treated by rigid internal fixation.
Wong, G B
1993-09-01
Mandibular fractures in the pediatric patient population are relatively uncommon. These patients present with their own unique treatment requirements. Most fractures have been treated conservatively by dental splints. Closed reduction techniques with maxillomandibular fixation (MMF) in very young children can pose several concerns, including cooperation, compliance and adequate nutritional intake. Rigid internal fixation of unstable mandibular fractures using miniplates and screws circumvents the need for MMF and allows immediate jaw mobilization. At major pediatric trauma institutions, there has been an increasing trend toward the use of this treatment when open reduction is necessary. This article presents a report of a five-year-old child who presented with bilateral mandibular fractures and was treated by rigid internal fixation and immediate mandibular mobilization.
Sharma, Krishn M; Parks, Brent G; Nguyen, Augustine; Schon, Lew C
2005-10-01
A change in screw orientation in fixing the chevron proximal first metatarsal osteotomy was noted anecdotally to improve fixation strength. The authors hypothesized that plantar-to-dorsal screw orientation would be more stable than the conventional dorsal-to-plantar screw orientation for fixation of the chevron osteotomy. The purpose of this study was to determine if the load-to-failure and stiffness of the chevron type proximal first metatarsal osteotomy stabilized using plantar-to-dorsal screw fixation were greater than with the more conventional dorsal-to-plantar screw fixation method. One foot from each of eight matched cadaver pairs was randomly assigned to one of two groups: 1) fixation with a dorsal-to-plantar lag screw or 2) fixation with a plantar-to-dorsal lag screw. A proximal chevron osteotomy was then created using standard technique and the metatarsal was fixed according to previously established method. The bone was potted in polyester resin, and the construct was fitted into a materials testing system machine in which load was applied to the plantar aspect of the metatarsal until failure. The two groups were compared using a two-tailed Student t test. The average load-to-failure and stiffness of the chevron osteotomy fixed with the plantar-to-dorsal lag screw were significantly greater (p < 0.05) than the group fixed with more conventional dorsal-to-plantar lag screws. Plantar-to-dorsal screw orientation was more stable than the conventional dorsal-to-plantar screw orientation for fixation of the proximal chevron osteotomy. Plantar-to-dorsal screw orientation should be considered when using the chevron proximal first metatarsal osteotomy.
Metcalfe, David; Hickson, Craig J; McKee, Lesley; Griffin, Xavier L
2015-12-01
It is uncertain whether external fixation or open reduction internal fixation (ORIF) is optimal for patients with bicondylar tibial plateau fractures. A systematic review using Ovid MEDLINE, Embase Classic, Embase, AMED, the Cochrane Library, Open Grey, Orthopaedic Proceedings, WHO International Clinical Trials Registry Platform, Current Controlled Trials, US National Institute for Health Trials Registry, and the Cochrane Central Register of Controlled Trials. The search was conducted on 3rd October 2014 and no language limits were applied. Inclusion criteria were all clinical study designs comparing external fixation with open reduction internal fixation of bicondylar tibial plateau fractures. Studies of only one treatment modality were excluded, as were those that included unicondylar tibial plateau fractures. Treatment effects from studies reporting dichotomous outcomes were summarised using odds ratios. Continuous outcomes were converted to standardized mean differences to assess the treatment effect, and inverse variance methods used to combine data. A fixed effect model was used for meta-analyses. Patients undergoing external fixation were more likely to have returned to preinjury activities by six and twelve months (P = 0.030) but not at 24 months follow-up. However, external fixation was complicated by a greater number of infections (OR 2.59, 95 % CI 1.25-5.36, P = 0.01). There were no statistically significant differences in the rates of deep infection, venous thromboembolism, compartment syndrome, or need for re-operation between the two groups. Although external fixation and ORIF are associated with different complication profiles, both are acceptable strategies for managing bicondylar tibial plateau fractures.
Katsenis, Dimitris; Athanasiou, Vasilis; Vasilis, Athanasiou; Megas, Panayiotis; Panayiotis, Megas; Tyllianakis, Minos; Minos, Tillianakis; Lambiris, Elias
2005-04-01
To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.
Larsson, Sune; Procter, Philip
2011-09-01
When stabilising a fracture the contact between the screw and the surrounding bone is crucial for mechanical strength. Through development of screws with new thread designs, as well as optimisation of other properties, improved screw purchase has been gained. Other alternatives to improve screw fixation in osteoporotic bone, as well as normal bone if needed, includes the use of various coatings on the screw that will induce a bonding between the implant surface and the bone implant, as well as application of drugs such as bisphosphonates locally in the screw hole to induce improved screw anchorage through their anticatabolic effect on the bone tissue. As failure of internal fixation of fractures in osteoporotic bone typically occurs through breakage of the bone that surrounds the implant, rather than the implant itself, an alternative strategy in osteoporotic bone can include augmentation of the bone around the screw. This is useful when screws alone are being used for fixation, as it will increase pull-out resistance, but also when conventional plates and screws are used. In angularly stable plate-screw systems, screw back-out is not a problem if the locking mechanism between the screws and the plate works. However, augmentation that will strengthen the bone around the screws can also be useful in conjunction with angle-stable plate-screw systems, as the augmentation will provide valuable support when subjected to loading that might cause cut-out. For many years conventional bone cement, polymethylmethacrylate (PMMA), has been used for augmentation, but due to side effects--including great difficulties if removal becomes necessary--the use of PMMA has never gained wide acceptance. With the introduction of bone substitutes, such as calcium phosphate cement, it has been shown that augmentation around screws can be achieved without the drawbacks seen with PMMA. When dealing with fixation of fractures in osteoporotic bone where screw stability might be inadequate, it therefore seems an attractive option to include bone substitutes for augmentation around screws as part of the armamentarium. Clinical studies now are needed to determine the indications in which bone augmentation with bone-graft substitutes (BGSs) would merit clinical usage. Copyright © 2011. Published by Elsevier Ltd.
Elliott, E; Dennison, C; Fortgens, P H; Travis, J
1995-10-01
Paraformaldehyde (PFA) fixation was optimized to facilitate the immobilization and labeling of multiple granule antigens, using short fixation regimens and cryoultramicrotomy of unembedded neutrophils (PMNs). In the optimal protocol, extraction of azurophil granule antigens (especially of the abundant elastase) was obviated by manipulating the polymeric state of PFA, and hence its rate of cross-linking, by altering its concentration and pH in a multistep process. Primary fixation conditions used (4% PFA, pH 8.0, 5 min) favor fixative penetration and rapid cross-linking. Stable cross-linking of the antigen was achieved in a secondary fixation step using conditions that favor larger, more cross-linking polymeric forms of PFA (8% PFA, pH 7.2, 15 min). Immobilization of granule antigens was enhanced by flotation of cut sections on fixative (8% PFA, pH 8.0) before labeling and by using post-labeling fixation with 1% glutaraldehyde. The optimized protocol facilitated immobilization and immunolabeling of elastase, myeloperoxidase, lactoferrin, and cathepsin D in highly hydrated, unembedded PMNs.
NIR tracking assists sports medicine in junior basketball training
NASA Astrophysics Data System (ADS)
Paeglis, Roberts; Bluss, Kristaps; Rudzitis, Andris; Spunde, Andris; Brice, Tamara; Nitiss, Edgars
2011-07-01
We recorded eye movements of eight elite junior basketball players. We hypothesized that a more stable gaze is correlated to a better shot rate. Upon preliminary testing we invited male juniors whose eyes could be reliably tracked in a game situation. To these ends, we used a head-mounted video-based eye tracker. The participants had no record of ocular or other health issues. No significant differences were found between shots made with and without the tracker cap, Paired samples t-test yielded p= .130 for the far and p=..900 > .050 for the middle range shots. The players made 40 shots from common far and middle range locations, 5 and 4 meters respectively for aged 14 years As expected, a statistical correlation was found between gaze fixation (in milliseconds) for the far and middle range shot rates, r=.782, p=.03. Notably, juniors who fixated longer before a shot had a more stable fixation or a lower gaze dispersion (in tracker's screen pixels), r=-.786, p=.02. This finding was augmented by the observation that the gaze dispersion while aiming at the basket was less (i.e., gaze more stable) in those who were more likely to score. We derived a regression equation linking fixation duration to shot success. We advocate infra-red eye tracking as a means to monitor player selection and training success.
Jennings, Ryan de Montmollin; Moran, James J.; Jay, Zackary J.; ...
2017-02-03
Biological fixation of CO 2 is the primary mechanism of C reduction in natural systems, and provides a diverse suite of organic compounds utilized by chemoorganoheterotrophs. The extent and mechanisms of CO 2 fixation were evaluated across a comprehensive set of high-temperature, chemotrophic microbial communities in Yellowstone National Park by combining metagenomic and stable 13C isotope analyses. Fifteen geothermal sites representing three distinct habitat types (iron-oxide mats, anoxic sulfur sediments, and filamentous ‘streamer’ communities) were investigated. Genes of the 3-hydroxypropionate/4-hydroxybutyrate, dicarboxylate/4-hydroxybutyrate, and reverse tricarboxylic acid CO 2 fixation pathways were identified in assembled genome sequence corresponding to the predominant Crenarchaeotamore » and Aquificales observed across this habitat range. Stable 13C analyses of dissolved inorganic and organic C (DIC, DOC), and possible landscape C sources were used to interpret the 13C content of microbial community samples. Isotope mixing models showed that the minimum amounts of autotrophic C in microbial biomass were > 50 % in the majority of communities analyzed, but were also dependent on the amounts of heterotrophy and/or accumulation of landscape C. Furthermore, the significance of CO 2 as a C source in these communities provides a foundation for understanding metabolic linkages among autotrophs and heterotrophs, community assembly and succession, and the likely coevolution of deeply-branching thermophiles.« less
Wu, Quan-Zhou; Huang, Shu-Ming; Cai, Qi-Xun; Chu, Xu-Feng
2017-01-25
To compare the complications and clinical outcome of titanium elastic nail(TEN) versus K-wire fixation(KW) for the treatment of displaced radial neck fractures in children. From January 2009 to December 2014, 56 children with displaced radial neck fractures were studied retrospectively according to the inclusion criteria. Based on the different methods of internal fixation, patients were divided into two groups: titanium elastic nail (TEN group) and K-wire fixation (KW group). Among 25 patients(15 males and 11 females, aged from 3 to 12 years old with an average of 8.6±2.1) treated with TEN, 16 patients had type III fractures, 19 patients had type IV fractures according to Metaizeau-Judet modified classification; 20 patients were treated with closed reduction and 5 patients were treated with open reduction; the time from injury to treatment ranged from 1 to 8 days with an average of (3.6±1.7) days. Among 31 patients (20 males and 11 females, aged from 3 to 11 years old with an average of 9.1±1.9 years old) treated with KW, 19 patients had type III fractures, 12 patients had type IV fractures; 22 patients were treated with closed reduction, and 9 patients were treated with open reduction; the time from injury to treatment ranged from 2 to 7 days with an average of (3.7±1.5) days. No significant differences between two groups were found in general data. Operative time, hospitalization time, healing time of fracture, internal fixation time, postoperative complications and function recovery of the two groups were compared and evaluated. The average follow-up period of the patients was 22.1 months in TEN group(ranged, 16 to 48 months), and 21.9 months in KW group(ranged, 13 to 48 months). There were no significant differences between these 2 groups in follow-up duration, average hospitalization time and fracture healing time. The operation time, hospital costs and internal fixation time in TEN group were (56.6±11.8) min, (18 000±3 000) Yuan(RMB), (9.1±2.5) weeks respectively; and in KW group were(45.5±10.3) min, (8 000±1 000) Yuan(RMB), (4.8±1.6) weeks respectively, there were significant differences between two groups( P <0.05). Outcome scores according to Metaizeau and Tibone-Stoltz had no significant differences between two groups( P >0.05). There is no significant difference of therapeutic effects between TEN and KW for children with displaced radial neck fractures. Because the removal of TEN fixation requires the secondary anesthesia, and the TEN costs significantly more than KW, TEN still can't replace the traditional KW for the treatment of radial neck fracture in children.
Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao
2016-03-01
To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.
Natoli, R M; Baer, M R; Bednar, M S
2016-05-01
Distal radius fractures are common injuries treated in a multitude of ways. One treatment paradigm not extensively studied is initial treatment by external fixation (EF) followed by conversion to open reduction internal fixation (ORIF). Such a paradigm may be beneficial in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. There is no increased risk of infection when converting EF to ORIF in the treatment of complex distal radius fractures when conversion occurs early or if EF pin sites are overlapped by the definitive fixation. Using an IRB approved protocol, medical records over nine years were queried to identify patients with distal radius fractures that had undergone initial EF and were later converted to ORIF. Charts were reviewed for demographic data, injury characteristics, operative details, time to conversion from EF to ORIF, assessment of whether the EF pin sites overlapped the definitive fixation, presence of infection after ORIF, complications, and occupational therapy measurements of range of motion and strength. In total, 16 patients were identified, only one of which developed an infection following conversion to ORIF. Fisher's exact testing showed that infection did not depend on open fracture, time to conversion of one week or less, presence of EF pin sites overlapping definitive fixation, fracture classification, high energy mechanism of injury, or concomitant injury to the DRUJ. Planned staged conversion from EF to ORIF for complex distal radius fractures does not appear to result in an increased rate of infection if conversion occurs early or if the EF pin sites are overlapped by definitive fixation. This treatment paradigm may be reasonable for treating complex distal radius fractures in damage control situations, when there is extensive soft tissue injury, or when appropriate personnel/hospital resources are not available for immediate internal fixation. IV, retrospective case series. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter
2018-02-01
Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.
Pediatric mandibular fractures.
Schweinfurth, J M; Koltai, P J
1998-01-01
Over the last 20 years, a revolution in the management of facial fractures has taken place. Refinements in biocompatible materials of great delicacy and strength along with advances in our understanding of biomechanics of the face, have rendered complex injuries consistently amenable to accurate 3-dimensional reconstruction. Furthermore, with the availability of education in the techniques of internal rigid fixation, these advanced techniques have become routine practice in adults. However, the suitability of rigid internal fixation for children remains controversial. There are many concerns about the effect of implanted hardware in the mandible of a growing child. In addition, some evidence suggests that the elevation of functional matrix off of bone may result in alterations in development. The goal is to restore the underlying bony architecture to its pre-injury position in a stable fashion, with a minimal of aesthetic and functional impairment. However, in children the treatment of bony injuries is most easily accomplished by techniques that may adversely effect craniofacial development. While it is not entirely possible to resolve this dilemma, there exists an extensive body of experimental and clinical information on the appropriate management of pediatric mandibular fractures which can be used to formulate a rational treatment plan for most cases. This paper presents an overview of the contemporary understanding and application of these treatment principles.
Kim, Bong Chul; Padwa, Bonnie L; Park, Hyung-Sik; Jung, Young-Soo
2011-05-01
The purpose of this study was to evaluate the stability of Le Fort I osteotomy using self-reinforced biodegradable poly-70L/30DL-lactide miniplates and screws. Nineteen patients who had Le Fort I osteotomy and internal fixation using self-reinforced biodegradable poly-70L/30DL-lactide miniplates and screws were evaluated both radiographically and clinically. Changes in maxillary position after operation were documented 1 week, 1, 3, 6 mo, and/or 1-yr postoperatively with lateral cephalometric tracings. Complications of the self-reinforced biodegradable poly-70L/30DL-lactide miniplates and screws were evaluated by follow-up roentgenograms and clinical observation. A mixed model analysis for repeated measures was used for statistical analysis. Maxillary position was stable after operation with no change between time points (P > .05). There were no complications with the self-reinforced biodegradable poly-70L/30DL-lactide miniplates and screws. Internal fixation of the maxilla after Le Fort I osteotomy with self-reinforced biodegradable poly-70L/30DL-lactide miniplates and screws is a reliable method for maintaining the postoperative maxillary position after Le Fort I osteotomy. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Zhu, Jie; Usov, Pavel M; Xu, Wenqian; Celis-Salazar, Paula J; Lin, Shaoyang; Kessinger, Matthew C; Landaverde-Alvarado, Carlos; Cai, Meng; May, Ann M; Slebodnick, Carla; Zhu, Dunru; Senanayake, Sanjaya D; Morris, Amanda J
2018-01-24
Metal-organic frameworks (MOFs) have shown great promise in catalysis, mainly due to their high content of active centers, large internal surface areas, tunable pore size, and versatile chemical functionalities. However, it is a challenge to rationally design and construct MOFs that can serve as highly stable and reusable heterogeneous catalysts. Here two new robust 3D porous metal-cyclam-based zirconium MOFs, denoted VPI-100 (Cu) and VPI-100 (Ni), have been prepared by a modulated synthetic strategy. The frameworks are assembled by eight-connected Zr 6 clusters and metallocyclams as organic linkers. Importantly, the cyclam core has accessible axial coordination sites for guest interactions and maintains the electronic properties exhibited by the parent cyclam ring. The VPI-100 MOFs exhibit excellent chemical stability in various organic and aqueous solvents over a wide pH range and show high CO 2 uptake capacity (up to ∼9.83 wt% adsorption at 273 K under 1 atm). Moreover, VPI-100 MOFs demonstrate some of the highest reported catalytic activity values (turnover frequency and conversion efficiency) among Zr-based MOFs for the chemical fixation of CO 2 with epoxides, including sterically hindered epoxides. The MOFs, which bear dual catalytic sites (Zr and Cu/Ni), enable chemistry not possible with the cyclam ligand under the same conditions and can be used as recoverable stable heterogeneous catalysts without losing performance.
Inverted distal clavicle anatomic locking plate for displaced medial clavicle fracture.
Wang, Yong; Jiang, Jiannong; Dou, Bin; Zhang, Panjun
2015-09-01
Fractures of the medial clavicle are rare injuries. Recently, open reduction and internal fixation has been recommended for displaced medial clavicle fractures in order to prevent non-union and dysfunction. Because of the rarity of this injury, the optimal fixation device has not yet been established. In this report, we describe a case of a 40-year-old male patient who sustained a significantly displaced medial clavicle fracture treated by open reduction and internal fixation using an inverted distal clavicle anatomic locking plate. At the 12 months follow-up, the patient recovered well, had returned to pre-injury job, and was quite satisfied with the outcome. Internal fixation of medial clavicle fracture using an inverted distal clavicle anatomic locking plate of the ipsilateral side appears to be a good treatment option.
Osterhoff, G; Tiziani, S; Hafner, C; Ferguson, S J; Simmen, H-P; Werner, C M L
2016-04-01
This study investigates the biomechanical stability of a novel technique for symphyseal internal rod fixation (SYMFIX) using a multiaxial spinal screw-rod implant that allows for direct reduction and can be performed percutaneously and compares it to standard internal plate fixation of the symphysis. Standard plate fixation (PLATE, n = 6) and the SYMFIX (n = 6) were tested on pelvic composite models with a simulated open book injury using a universal testing machine. On a previously described testing setup, 500 consecutive cyclic loadings were applied with sinusoidal resulting forces of 200 N. Displacement under loading was measured using an optoelectronic camera system and construct rigidity was calculated as a function of load and displacement. The rigidity of the PLATE construct was 122.8 N/mm (95 % CI: 110.7-134.8), rigidity of the SYMFIX construct 119.3 N/mm (95 % CI: 105.8-132.7). Displacement in the symphyseal area was mean 0.007 mm (95 % CI: 0.003-0.012) in the PLATE group and 0.021 mm (95 % CI: 0.011-0.031) in the SYMFIX group. Displacement in the sacroiliac joint area was mean 0.156 mm (95 % CI: 0.051-0.261) in the PLATE group and 0.120 mm (95 % CI: 0.039-0.201) in the SYMFIX group. In comparison to standard internal plate fixation for the stabilization of open book pelvic ring injuries, symphyseal internal rod fixation using a multiaxial spinal screw-rod implant in vitro shows a similar rigidity and comparable low degrees of displacement.
Li, Jiaming; Wang, Decheng; He, Zhiliang; Shi, Hao
2018-01-08
To determine the efficacy of modified titanium tension band plus patellar tendon tunnel steel 8 "reduction band" versus titanium cable tension band fixation for the treatment of patellar lower pole fracture. 58 patients with lower patella fracture were enrolled in this study, including 30 patients treated with modified titanium cable tension band plus patellar tibial tunnel wire "8" tension band internal fixation (modified group), and 28 patients with titanium cable tension band fixation. All patients were followed up for 9∼15 months with an average of 11.6 months. Knee flexion was significantly improved in the modified group than in the titanium cable tension band group (111.33 ± 13 degrees versus 98.21 ± 21.70 degrees, P = 0.004). The fracture healing time showed no significant difference. At the end of the follow-up, the improvement excellent rate was 93.33% in the modified group, and 82.14% in the titanium cable tension band group. Titanium cable tension band internal fixation loosening was found in 2 cases, including 1 case of treatment by two surgeries without loose internal fixation. The modified titanium cable tension band with "8" tension band fixation showed better efficacy for lower patella fractures than titanium cable tension band fixation.
Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira
2015-12-01
The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Fibrin glue versus autologous blood for conjunctival autograft fixation in pterygium surgery.
Boucher, Sophie; Conlon, Ronan; Teja, Salina; Teichman, Joshua C; Yeung, Season; Ziai, Setareh; Baig, Kashif
2015-08-01
To compare the outcomes between autologous blood- and fibrin glue-fixated conjunctival autografts in pterygium excision surgery. Retrospective case series. Forty eyes of 40 patients who had a primary nasal pterygium excision. A retrospective comparative case series of 40 eyes (40 patients) that had a primary nasal pterygium excision. All eyes had a conjunctival autograft from the superior bulbar conjunctiva to cover the scleral bed. Twenty eyes (20 patients) had fixation of the autograft using autologous blood (AB), and 20 eyes (20 patients) had fixation using fibrin glue (FG). One year of follow-up data included conjunctival graft stability (graft loss, graft retraction), pterygium recurrence, visual acuity, and postoperative complications. Descriptive and inferential statistics were performed. Intraoperatively, no complications occurred in either group. Graft loss occurred in 6 patients in the AB group, compared with none in the FG group. Graft retraction occurred in 3 patients in the AB group and 2 patients in the FG group. At 1 year postoperatively, pterygium recurrence occurred in 4 patients in the AB group and 1 patient in the FG group. One patient in the AB group developed a small pyogenic granuloma that resolved by 6 months with conservative management. Visual acuity remained stable in both groups. Conjunctival autograft fixation with autologous blood resulted in less stable conjunctival autografts and a higher recurrence rate compared with fixation with fibrin glue. Copyright © 2015 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Zhu, Zhonglin; Ding, Hui; Shao, Hongyi; Zhou, Yixin; Wang, Guangzhi
2013-04-09
The wire fixation and the cable grip fixation have been developed for the extended trochanteric osteotomy (ETO) in the revision of total hip arthroplasty (THA). Many studies reported the postoperative performance of the patients, but with little quantitative biomechanical comparison of the two fixation systems. An in-vitro testing approach was designed to record the loosening between the femoral bed and the greater trochanter after fixations. Ten cadaveric femurs were chosen in this study. Each femur underwent the THA, revision by ETO and fixations. The tension to the greater trochanter was from 0 to 500N in vertical and lateral direction, respectively. The translation and rotation of the greater trochanter with respect to the bony bed were captured by an optical tracking system. In the vertical tension tests, the overall translation of the greater trochanter was observed 0.4 mm in the cable fixations and 7.0 mm in the wire fixations. In the lateral tension tests, the overall motion of the greater trochanter was 2.0 mm and 1.2° in the cable fixations, while it was 6.2 mm and 5.3° in the wire fixations. The result was significantly different between the two fixation systems. The stability of the proximal femur after ETO using different fixations in the revision THA was investigated. The cable grip fixation was significantly more stable than the wire fixation.
Fixation of strategies with the Moran and Fermi processes in evolutionary games
NASA Astrophysics Data System (ADS)
Liu, Xuesong; He, Mingfeng; Kang, Yibin; Pan, Qiuhui
2017-10-01
A model of stochastic evolutionary game dynamics with finite population was built. It combines the standard Moran and Fermi rules with two strategies cooperation and defection. We obtain the expressions of fixation probabilities and fixation times. The one-third rule which has been found in the frequency dependent Moran process also holds for our model. We obtain the conditions of strategy being an evolutionarily stable strategy in our model, and then make a comparison with the standard Moran process. Besides, the analytical results show that compared with the standard Moran process, fixation occurs with higher probabilities under a prisoner's dilemma game and coordination game, but with lower probabilities under a coexistence game. The simulation result shows that the fixation time in our mixed process is lower than that in the standard Fermi process. In comparison with the standard Moran process, fixation always takes more time on average in spatial populations, regardless of the game. In addition, the fixation time decreases with the growth of the number of neighbors.
Tan, Hong-lie; Qian, Chen; Zhao, Jin-kun; Shi, Yan; Zhou, Qi
2009-02-01
To study the clinical efficacy of the treatment of comminuted patellar fractures with internal NiTi-Patellar concentrator and tension bind wire fixation. From March 2004 to June 2007, 38 cases of fresh comminuted patellar fractures were treated with internal NiTi-Patellar concentrator and tension bind wire fixation. There were 25 males and 13 females,ranging from 21 to 64 years (mean 42.5 years). All were comminuted fractures with displacement, 16 cases were 3 fragments, 14 cases were 4 fragments, 8 cases were 5 fragments. There were other fractures in 8 cases. During followed-up, knee function and complications were evaluated. All patients were followed up for 8 to 24 months (mean 15 months) and obtained complete bone union. No case of implant was loosening and fragment displacement, traumatic arthritis occured in 2 cases. Under Lysholm & Gillquist score, the results were excellent in 17 cases, good in 19, fair in 2. Internal Ni-Ti-Patellar concentrator and tension bind wire fixation is one of the ideal methods for the treatment of comminuted patellar fracture, which could provide satisfied reduction, reliable fixation and good functional recovery.
Santos, Antonio; Moreira, Fernando
2014-01-01
With objective of analyzing the mechanical behavior of the internal fixators of spine and of the bony structure, the pieces and the group were made (it structures bony x internal fixator) with the aid a software of solid modeling. The materials used in the rehearsals had been the titanium, now in the market and a castor oil polyurethane destined to the development of you implant bony. PMID:24825938
Mathew, G; Kowalczuk, M; Hetaimish, B; Bedi, A; Philippon, M J; Bhandari, M; Simunovic, N; Crouch, S; Ayeni, O R
2014-04-01
The purpose of this study was to estimate the radiographic prevalence of CAM-type femoroacetabular impingement (FAI) in elderly patients (≥ 50 years) who have undergone internal fixation for femoral neck fracture. A total of 187 frog-leg lateral radiographs of elderly patients who underwent internal fixation for a femoral neck fracture were reviewed by two independent reviewers. The alpha angle, beta angle, and femoral head-neck offset ratio were calculated. The presence of two abnormal radiographic parameters was deemed to be diagnostic of radiographic CAM-type impingement. Radiographic CAM-type FAI was identified in 157 out of 187 (84 %) patients who underwent internal fixation for fractures of the femoral neck. Moderate-to-good inter-observer reliability was achieved in the measurement of radiographic parameters. With reference to fracture subtypes and prevalence of radiographic features of CAM-type morphology, 97 (72 %) out of 134 patients were positive for CAM in Garden subtypes I and II, whereas 49 (85.9 %) out of 57 patients had radiographic CAM in Garden III and IV subtypes. There was a high prevalence of CAM-type FAI in patients that underwent surgical fixation of femoral neck fractures. This is significantly higher than the reported prevalence in non-fracture patient populations. The high prevalence of CAM morphology could be related to several factors, including age, fracture morphology, quality of reduction, type of fixation, and fracture healing.
Liu, Jinliang; Li, Keyao; Ju, Zhenlong; Bai, Yan
2011-03-01
To study the indications, methods and experience of absorbable rib-connecting-pins fixation in the treatment of multiple rib fractures. 52 cases with multiple rib fractures were performed internal fixation with absorbable rib-connecting-pins under epidural anesthesia. All cases were followed up for 1 to 12 months, with an average of 5 months. All fractures were achieved healing in 3 to 6 months after the operation and were not found chest wall deformity. Absorbable rib-connecting-pins fixation is a simple and effective method and worthies recommending to perform operation for the appropriate cases with multiple rib fractures.
Tiwana, Paul S; Kushner, George M; Alpert, Brian
2007-06-01
To review, retrospectively, the outcomes of 102 patients who underwent lag screw technique fixation of fractures of the anterior mandible. A total of 102 consecutive, skeletally mature patients who have undergone open reduction internal fixation for fractures of the anterior mandible utilizing the lag screw technique were reviewed. All patients had a clinically mobile fracture between the mental foramina of the mandible. The patients were followed at usual postoperative intervals with shortest long-term follow-up of 2 months. Intraoperative and long-term postoperative outcomes including status of union, infection, and intraoperative surgical misadventure were recorded. Data from the 102 patients showed that there was 1 fixation failure due to inappropriate patient selection, 1 nonunion requiring bone grafting, 1 with infected screws but with union, 1 with an infected screw and delayed union treated conservatively, and 6 with broken drills from intraoperative surgical misadventures. Lag screw osteosynthesis of anterior mandibular fractures is a sensitive, facile, predictable, and relatively inexpensive method for internal fixation of indicated fractures. As with all methods of rigid internal fixation, most failures or complications are the result of operator judgment or technique.
Zeng, Canjun; Xiao, Jidong; Wu, Zhanglin; Huang, Wenhua
2015-01-01
The aim of this study is to evaluate the efficacy and feasibility of three-dimensional printing (3D printing) assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach. A total of 38 patients with unstable pelvic fractures were analyzed retrospectively from August 2012 to February 2014. All cases were treated operatively with internal fixation assisted by three-dimensional printing from minimal invasive para-rectus abdominis approach. Both preoperative CT and three-dimensional reconstruction were performed. Pelvic model was created by 3D printing. Data including the best entry points, plate position and direction and length of screw were obtained from simulated operation based on 3D printing pelvic model. The diaplasis and internal fixation were performed by minimal invasive para-rectus abdominis approach according to the optimized dada in real surgical procedure. Matta and Majeed score were used to evaluate currative effects after operation. According to the Matta standard, the outcome of the diaplasis achieved 97.37% with excellent and good. Majeed assessment showed 94.4% with excellent and good. The imageological examination showed consistency of internal fixation and simulated operation. The mean operation time was 110 minutes, mean intraoperative blood loss 320 ml, and mean incision length 6.5 cm. All patients have achieved clinical healing, with mean healing time of 8 weeks. Three-dimensional printing assisted internal fixation of unstable pelvic fracture from minimal invasive para-rectus abdominis approach is feasible and effective. This method has the advantages of trauma minimally, bleeding less, healing rapidly and satisfactory reduction, and worthwhile for spreading in clinical practice.
Rostral mandibular fracture repair in a pet bearded dragon (Pogona vitticeps).
Nau, Melissa R; Eshar, David
2018-04-15
CASE DESCRIPTION A 2-year-old male bearded dragon (Pogona vitticeps) was evaluated because of a traumatic mandibular fracture. CLINICAL FINDINGS An open comminuted fracture of the rostral aspect of the right mandible was evident, with a fragment of bone exposed and dorsally displaced. Whole-body radiography revealed no evidence of additional injury. Other findings were unremarkable, except for moderate anemia (PCV, 19%). TREATMENT AND OUTCOME The fracture fragments were stabilized with 2 crossed 36-gauge interfragmentary wire loops. An external fixator device was fashioned from four 25-gauge needles inserted at alternating angles through the fracture fragments; plastic IV fluid line tubing filled with dental acrylic was used as a connecting bar. One day after surgery, the lizard had regained its typical activity level and appetite. Body weight was measured and the external fixator was inspected 1 week after surgery and monthly thereafter. Three months after initial injury, the fracture was stable, radiography revealed bony callus formation at the fracture site, and the external fixator was removed. Recheck radiography performed 5.5 months after initial injury revealed complete osseous union of the fracture fragments, and the interfragmentary wires were removed. CLINICAL RELEVANCE Surgical management of the traumatic comminuted mandibular fracture in this bearded dragon by means of a combination of internal and external fixation resulted in complete healing of the mandible and restoration of function. Management of this complicated fracture was achieved with the aid of readily available and inexpensive supplies in a clinical setting, which may be useful to other clinicians in the management of similar cases.
Andersen, Robert C; Neiderer, Katherine; Martin, Billy; Dancho, James
2013-01-01
Body fractures of the tarsal navicular are relatively uncommon. To date, there is little literature discussing a navicular body fracture with dorsal subluxation of the first and second cuneiforms over the navicular. This case study presents a 30-year-old patient with this injury. He underwent open reduction internal fixation of the navicular body fracture successfully but failed adequate reduction of the navicular cuneiform joint after ligamentous reconstruction. After revisional surgery, he also failed 6 weeks of percutanous pinning with Kirschner-wire fixation. When comparing the literature of a similar injury, the Lisfranc fracture disclocation, the same principles may apply. One should consider rigid open reduction internal fixation or even primary fusion to treat disclocation of the naviculocuneiform joint following a navicular body fracture.
Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim
2017-04-01
Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.
Biomechanical Concepts for Fracture Fixation
Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.
2015-01-01
Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263
Kim, Young-Ho
2017-09-01
The use of acetabular cup revision arthroplasty is on the rise as demands for total hip arthroplasty, improved life expectancies, and the need for individual activity increase. For an acetabular cup revision to be successful, the cup should gain stable fixation within the remaining supportive bone of the acetabulum. Since the patient's remaining supportive acetabular bone stock plays an important role in the success of revision, accurate classification of the degree of acetabular bone defect is necessary. The Paprosky classification system is most commonly used when determining the location and degree of acetabular bone loss. Common treatment options include: acetabular liner exchange, high hip center, oblong cup, trabecular metal cup with augment, bipolar cup, bulk structural graft, cemented cup, uncemented cup including jumbo cup, acetabular reinforcement device (cage), trabecular metal cup cage. The optimal treatment option is dependent upon the degree of the discontinuity, the amount of available bone stock and the likelihood of achieving stable fixation upon supportive host bone. To achieve successful acetabular cup revision, accurate evaluation of bone defect preoperatively and intraoperatively, proper choice of method of acetabular revision according to the evaluation of acetabular bone deficiency, proper technique to get primary stability of implant such as precise grafting technique, and stable fixation of implant are mandatory.
Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul
2015-01-01
To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.
The use of resorbable hardware for fixation of pediatric mandible fracture. Case report.
Poore, Matthew C; Penna, Kevin J
2008-01-01
The diagnosis and management of mandible fractures in the pediatric patient population can pose multiple challenges to the oral and maxillofacial surgeon. Resorbable plates and screws for fixation in this population are both well tolerated and effective. They enable realignment and stable positioning of rapidly healing fracture segments, while obviating any potential impediments to long-term metal retention.
Ford, Samuel E; Ellington, J Kent
2017-08-01
Difficult problems that are faced when reconstructing severe pilon fractures include filling metaphyseal defects and supporting an impacted, multifragmented articular surface. Supplements to plate fixation currently available in a surgeon's armamentarium include cancellous bone autograft, structural bone allograft, demineralized bone matrix, and calcium-based cements. Cancellous autograft possesses limited inherent mechanical stability and is associated with graft site morbidity. Structural allografts incorporate inconsistently and are plagued by late resorption. Demineralized bone matrix also lacks inherent structural stability. Calcium phosphate cements are not rigidly fixed to bone unless fixation is applied from cortical bone or through a plate, which must be taken into consideration when planning fixation. The Conventus DRS (Conventus Orthopaedics, Maple Grove, MN) implant is an expandable nitinol scaffold that takes advantage of the elasticity and shape memory of nitinol alloy. Once deployed and locked, it serves as a stable intramedullary base for fragment-specific periarticular fracture fixation, even in the face of metaphyseal bone loss. Two cases of successful implant use are presented. In both cases, the implant is used to fill a metaphyseal void and provide stable articular support to the distal tibial plafond. Therapeutic Level V: Case Report, Expert Opinion.
Wang, Yan-jie; Wang, Shi-gang; Miao, Shu-juan; Su, Xia
2011-06-01
To investigate the effects of open reduction by palm side for the distal radius fracture and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection for the prevention of delayed carpal tunnel syndrome after operation. From March 2000 to March 2007, 32 patients (8 males and 24 females, ranging in age from 46 to 66 years) with distal radius fracture were treated with open reduction by palm side and T shape plate internal fixation with simultaneous anterior transverse carpal ligament resection; while 30 patients (7 males and 23 females,ranging in age from 45 to 65 years) only with open reduction by palm side and T shape plate internal fixation. The incidences of delayed carpal tunnel syndrome between the two groups were compared. Among 32 patients treated with open reduction by palm side and T shape plate internal fixation with anterior transverse carpal ligament resection, 3 patients had delayed carpal tunnel syndrome; while in 30 patients treated with open reduction by palm side and T shape plate internal fixation, 10 patients had delayed carpal tunnel syndrome. There was significant statistically difference (P < 0.05%). Simultaneous anterior transverse carpal ligament resection can effectively prevent the delayed carpal tunnel syndrome occurrence for the distal radius fracture with open reduction by palm side.
Iundusi, Riccardo; Gasbarra, Elena; D'Arienzo, Michele; Piccioli, Andrea; Tarantino, Umberto
2015-05-13
Reduction of tibial plateau fractures and maintain a level of well aligned congruent joint is key to a satisfactory clinical outcome and is important for the return to pre-trauma level of activity. Stable internal fixation support early mobility and weight bearing. The augmentation with bone graft substitute is often required to support the fixation to mantain reduction. For these reasons there has been development of novel bone graft substitutes for trauma applications and in particular synthetic materials based on calcium phosphates and/or apatite combined with calcium sulfates. Injectable bone substitutes can optimize the filling of irregular bone defects. The purpose of this study was to assess the potential of a novel injectable bone substitute CERAMENT™|BONE VOID FILLER in supporting the initial reduction and preserving alignment of the joint surface until fracture healing. From June 2010 through May 2011 adult patients presenting with acute, closed and unstable tibial plateau fractures which required both grafting and internal fixation, were included in a prospective study with percutaneous or open reduction and internal fixation (ORIF) augmented with an injectable ceramic biphasic bone substitute CERAMENT™|BONE VOID FILLER (BONESUPPORT™, Lund, Sweden) to fill residual voids. Clinical follow up was performed at 1, 3, 9 and 12 months and any subsequent year; including radiographic analysis and Rasmussen system for knee functional grading. Twenty four patients, balanced male-to-female, with a mean age of 47 years, were included and followed with an average of 44 months (range 41-52 months). Both Schatzker and Müller classifications were used and was type II or 41-B3 in 7 patients, type III or 41-B2 in 12 patients, type IV or 41-C1 in 2 patients and type VI or 41-C3 in 3 patients, respectively. The joint alignement was satisfactory and manteined within a range of 2 mm, with an average of 1.18 mm. The mean Rasmussen knee function score was 26.5, with 14 patients having an excellent result and the remaining 10 with a good result. It can be concluded that radiological and clinical outcome was satisfactory and obtained in all cases without complications. This injectable novel biphasic hydroxyapatite and calcium sulfate ceramic material is a valuable armamentarium in the treatment of trauma where bone graft is required.
Fixation systems of greater trochanteric osteotomies: biomechanical and clinical outcomes.
Jarit, Gregg J; Sathappan, Sathappan S; Panchal, Anand; Strauss, Eric; Di Cesare, Paul E
2007-10-01
The development of cerclage systems for fixation of greater trochanteric osteotomies has progressed from monofilament wires to multifilament cables to cable grip and cable plate systems. Cerclage wires and cables have various clinical indications, including fixation for fractures and for trochanteric osteotomy in hip arthroplasty. To achieve stable fixation and eventual union of the trochanteric osteotomy, the implant must counteract the destabilizing forces associated with pull of the peritrochanteric musculature. The material properties of cables and cable grip systems are superior to those of monofilament wires; however, potential complications with the use of cables include debris generation and third-body polyethylene wear. Nevertheless, the cable grip system provides the strongest fixation and results in lower rates of nonunion and trochanteric migration. Cable plate constructs show promise but require further clinical studies to validate their efficacy and safety.
Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam
2013-01-01
Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504
Eye position changes during reading fixations are spatially selective.
Inhoff, Albrecht W; Solomon, Matthew S; Seymour, Bradley A; Radach, Ralph
2008-03-01
Intra-fixation location changes were measured when one-line sentences written in lower or aLtErNaTiNg case were read. Intra-fixation location changes were common and their size was normally distributed except for a relatively high proportion of fixations without a discernible location change. Location changes that did occur were systematically biased toward the right when alternating case was read. Irrespective of case type, changes of the right eye were biased toward the right at the onset of sentence reading, and this spatial bias decreased as sentence reading progressed from left to right. The left eye showed a relatively stable right-directed bias. These results show that processing demands can pull the two fixated eyes in the same direction and that the response to this pull can differ for the right and left eye.
Effect of allocentric landmarks on primate gaze behavior in a cue conflict task.
Li, Jirui; Sajad, Amirsaman; Marino, Robert; Yan, Xiaogang; Sun, Saihong; Wang, Hongying; Crawford, J Douglas
2017-05-01
The relative contributions of egocentric versus allocentric cues on goal-directed behavior have been examined for reaches, but not saccades. Here, we used a cue conflict task to assess the effect of allocentric landmarks on gaze behavior. Two head-unrestrained macaques maintained central fixation while a target flashed in one of eight radial directions, set against a continuously present visual landmark (two horizontal/vertical lines spanning the visual field, intersecting at one of four oblique locations 11° from the target). After a 100-ms delay followed by a 100-ms mask, the landmark was displaced by 8° in one of eight radial directions. After a second delay (300-700 ms), the fixation point extinguished, signaling for a saccade toward the remembered target. When the landmark was stable, saccades showed a significant but small (mean 15%) pull toward the landmark intersection, and endpoint variability was significantly reduced. When the landmark was displaced, gaze endpoints shifted significantly, not toward the landmark, but partially (mean 25%) toward a virtual target displaced like the landmark. The landmark had a larger influence when it was closer to initial fixation, and when it shifted away from the target, especially in saccade direction. These findings suggest that internal representations of gaze targets are weighted between egocentric and allocentric cues, and this weighting is further modulated by specific spatial parameters.
El-Mowafi, Hani; El-Hawary, Ahmed; Kandil, Yasser
2017-03-06
Charcot arthropathy of the peritalar complex carries a high risk of amputation if not properly managed. Our aim is to assess the functional outcome of severe Charcot arthropathy of the peritalar complex following enblock resection of the ulcer, massive debridement and stabilizing all the elements of the peritalar complex. We prospectively studied 38 feet in 35 patients with peritalar complex Charcot arthropathy. All Feet underwent intense debridement and fusion using a combination of (Ilizarov) external fixation, and (plate and locked nail) internal fixation. Thirty two feet were graded as Eichenholtz 2, and six feet were graded as Eichenholtz 3. The mean follow up was 35.9months. The mean AOFAS score was significantly elevated from 25.4±9.1 preoperatively to 67.6±5.7 at the most recent follow-up (p<0.001). Complete bony fusion was achieved in 28 feet. Unsound bony fusion occurred in 8 feet. Two feet required below knee amputation. Peritalar complex Charcot arthropathy is not uncommon variety. Such cases carry high risk of complications and amputation is not excluded. The proper timing of surgery is crucial. Massive debridement and rigid fixation with strict follow up is mandatory to achieve the ultimate goal of obtaining a plantigrade, stable, mechanically sound, painless and infection free pedal construct. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Intraoperative reduction of the scapular body--a technical trick.
Bartonícek, Jan; Fric, Vladimír; Tucek, Michal
2009-04-01
When internal fixation of the scapular neck and body fractures is performed, a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own technique of stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with an intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the "medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of fragments without compromising the subsequent fixation by plate screws.
Miniplate for osteosynthesis in a 9-year-old with symphysis fracture: clinical report.
Srinivasan, Ila; Kumar, Naveen; Jaganathan, Udhya; Bhandari, Arihant
2013-09-01
Osteosynthesis using minimum material in pediatric mandibular fractures is the key, due to the limited space available in the mandible, especially in the mental foramen and apical region. There is an important role of open reduction and rigid internal fixation in re-establishing facial height, width and projection. During the early years of growth and development, there is a high osteogenic potential of the bones. The thick periosteum allows for rapid consolidation and remodeling at the site of fracture. Primary teeth have short, bulbous crowns which compromise stable maxillomandibular fixation during fracture reduction and stabilization using traditional methods. Further, stability of the fractured segments may be hampered because of the displaced or mobile permanent anterior teeth in the mixed dentition along the line of fracture. This clinical report outlines the use of miniplate with monocortical screws in a 9-year-old boy with symphysis fracture. How to cite this article: Srinivasan I, Kumar N, Jaganathan U, Bhandari A. Miniplate for Osteosynthesis in a 9-Year-Old with Symphysis Fracture: Clinical Report. Int J Clin Pediatr Dent 2013;6(3):213-216.
Schmoelz, Werner; Sandriesser, Sabrina; Loebl, Oded; Bauer, Marlies; Krappinger, Dietmar
2017-10-01
There are various techniques and approaches for lumbar interbody fusion differing in access, cage type and type of supplemental posterior instrumentation. While a transforaminal access usually includes a hemifacetectomy, the facet joint can be preserved with a more lateral extraforaminal access. The supplemental posterior instrumentation required for both fusion techniques is still debated. The purpose of the present study was to compare primary stability of the two accesses for two different cage types with none, unilateral and bilateral supplemental posterior instrumentation. Six monosegmental lumbar functional spinal units (FSUs) were included in each of the two groups, and subjected to a flexibility test. As cages, a newly designed cage was compared to a standard cage in the following states: (a) native, (b) stand-alone cage, (c) bilateral internal fixator, (d) unilateral internal fixator, (e) unilateral facetectomy+bilateral internal fixator, (f) unilateral facetectomy+unilateral internal fixator and (g) unilateral facetectomy with stand-alone cage. For comparison the range of motion was normalized to the native state and the effects of the facetectomy, cage type, and supplemental instrumentation was compared. Within the subject comparison showed a significantly higher flexibility for the unilateral facetectomy in all motion directions (p<0.001). In between subject comparison showed a significant effect of cage type on flexibility in flexion/extension (p=0.002) and lateral bending (p=0.028) but not in axial rotation (p=0.322). The type of supplemental posterior fixation had a significant effect on the flexibility in all motion directions (stand-alone>unilateral fixator>bilateral fixator). Cage design and approach type are affecting the primary stability of lumbar interbody fusion procedures while the type of posterior instrumentation is the most influencing factor. Copyright © 2017 Elsevier Ltd. All rights reserved.
Cost-effectiveness analysis of fixation options for intertrochanteric hip fractures.
Swart, Eric; Makhni, Eric C; Macaulay, William; Rosenwasser, Melvin P; Bozic, Kevin J
2014-10-01
Intertrochanteric hip fractures are a major source of morbidity and financial burden, accounting for 7% of osteoporotic fractures and costing nearly $6 billion annually in the United States. Traditionally, "stable" fracture patterns have been treated with an extramedullary sliding hip screw whereas "unstable" patterns have been treated with the more expensive intramedullary nail. The purpose of this study was to identify parameters to guide cost-effective implant choices with use of decision-analysis techniques to model these common clinical scenarios. An expected-value decision-analysis model was constructed to estimate the total costs and health utility based on the choice of a sliding hip screw or an intramedullary nail for fixation of an intertrochanteric hip fracture. Values for critical parameters, such as fixation failure rate, were derived from the literature. Three scenarios were evaluated: (1) a clearly stable fracture (AO type 31-A1), (2) a clearly unstable fracture (A3), or (3) a fracture with questionable stability (A2). Sensitivity analysis was performed to test the validity of the model. The fixation failure rate and implant cost were the most important factors in determining implant choice. When the incremental cost for the intramedullary nail was set at the median value ($1200), intramedullary nailing had an incremental cost-effectiveness ratio of $50,000/quality-adjusted life year when the incremental failure rate of sliding hip screws was 1.9%. When the incremental failure rate of sliding hip screws was >5.0%, intramedullary nails dominated with lower cost and better health outcomes. The sliding hip screw was always more cost-effective for A1 fractures, and the intramedullary nail always dominated for A3 fractures. As for A2 fractures, the sliding hip screw was cost-effective in 70% of the cases, although this was highly sensitive to the failure rate. Sliding hip screw fixation is likely more cost-effective for stable intertrochanteric fractures (A1) or those with questionable stability (A2), whereas intramedullary nail fixation is more cost-effective for reverse obliquity fractures (A3). These conclusions are highly sensitive to the fixation failure rate, which was the major influence on the model results. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Jie; Usov, Pavel M.; Xu, Wenqian
Metal–organic frameworks (MOFs) have shown great promise in catalysis, mainly due to their high content of active centers, large internal surface areas, tunable pore size, and versatile chemical functionalities. However, it is a challenge to rationally design and construct MOFs that can serve as highly stable and reusable heterogeneous catalysts. Here two new robust 3D porous metal-cyclam-based zirconium MOFs, denoted VPI-100 (Cu) and VPI-100 (Ni), have been prepared by a modulated synthetic strategy. The frameworks are assembled by eight-connected Zr 6 clusters and metallocyclams as organic linkers. Importantly, the cyclam core has accessible axial coordination sites for guest interactions andmore » maintains the electronic properties exhibited by the parent cyclam ring. The VPI-100 MOFs exhibit excellent chemical stability in various organic and aqueous solvents over a wide pH range and show high CO 2 uptake capacity (up to ~9.83 wt% adsorption at 273 K under 1 atm). Moreover, VPI-100 MOFs demonstrate some of the highest reported catalytic activity values (turnover frequency and conversion efficiency) among Zr-based MOFs for the chemical fixation of CO 2 with epoxides, including sterically hindered epoxides. Thus, the MOFs, which bear dual catalytic sites (Zr and Cu/Ni), enable chemistry not possible with the cyclam ligand under the same conditions and can be used as recoverable stable heterogeneous catalysts without losing performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Jie; Usov, Pavel M.; Xu, Wenqian
Metal-organic frameworks (MOFs) have shown great promise in catalysis, mainly due to their high content of active centers, large internal surface areas, tunable pore size, and versatile chemical functionalities. However, it is a challenge to rationally design and construct MOFs that can serve as highly stable and reusable heterogeneous catalysts. Here two new robust 3D porous metal-cyclam-based zirconium MOFs, denoted VPI-100 (Cu) and VPI-100 (Ni), have been prepared by a modulated synthetic strategy. The frameworks are assembled by eight-connected Zr-6 clusters and metallocyclams as organic linkers. Importantly, the cyclam core has accessible axial coordination sites for guest interactions and maintainsmore » the electronic properties exhibited by the parent cyclam ring. The VPI-100 MOFs exhibit excellent chemical stability in various organic and aqueous solvents over a wide pH range and show high CO2 uptake capacity (up to similar to 9.83 wt% adsorption at 273 K under 1 atm). Moreover, VPI-100 MOFs demonstrate some of the highest reported catalytic activity values (turnover frequency and conversion efficiency) among Zr-based MOFs for the chemical fixation of CO2 with epoxides, including sterically hindered epoxides. The MOFs, which bear dual catalytic sites (Zr and Cu/Ni), enable chemistry not possible with the cyclam ligand under the same conditions and can be used as recoverable stable heterogeneous catalysts without losing performance.« less
Zhu, Jie; Usov, Pavel M.; Xu, Wenqian; ...
2017-12-22
Metal–organic frameworks (MOFs) have shown great promise in catalysis, mainly due to their high content of active centers, large internal surface areas, tunable pore size, and versatile chemical functionalities. However, it is a challenge to rationally design and construct MOFs that can serve as highly stable and reusable heterogeneous catalysts. Here two new robust 3D porous metal-cyclam-based zirconium MOFs, denoted VPI-100 (Cu) and VPI-100 (Ni), have been prepared by a modulated synthetic strategy. The frameworks are assembled by eight-connected Zr 6 clusters and metallocyclams as organic linkers. Importantly, the cyclam core has accessible axial coordination sites for guest interactions andmore » maintains the electronic properties exhibited by the parent cyclam ring. The VPI-100 MOFs exhibit excellent chemical stability in various organic and aqueous solvents over a wide pH range and show high CO 2 uptake capacity (up to ~9.83 wt% adsorption at 273 K under 1 atm). Moreover, VPI-100 MOFs demonstrate some of the highest reported catalytic activity values (turnover frequency and conversion efficiency) among Zr-based MOFs for the chemical fixation of CO 2 with epoxides, including sterically hindered epoxides. Thus, the MOFs, which bear dual catalytic sites (Zr and Cu/Ni), enable chemistry not possible with the cyclam ligand under the same conditions and can be used as recoverable stable heterogeneous catalysts without losing performance.« less
Li, Baichuan
2014-05-01
To explore the effectiveness of open reduction and internal fixation through anterior and posterior approaches in treatment of open Tile type C pelvic fractures at early stage. Between January 2009 and April 2012, 12 patients with open Tile C pelvic fractures were treated. There were 7 males and 5 females, aged 6-53 years (median, 31 years). Of 12 cases, 4 were classified as Tile type C1, 6 as Tile type C2, and 2 as Tile type C3; 5 were rated as Gustilo type II and 7 as Gustilo type III. The injury severity score was 18-57 (mean, 37.2). The interval of injury and admission ranged from 15 minutes to 3 days (median, 50 minutes). The debridement and external fixation were performed at first stage; then open reduction and internal fixation were used through anterior approach (reconstruction plate) and posterior approach (cannulated lag screws). The vacuum sealing drainage was performed during treatment until the wounds healed. Delayed healing of incison was obtained in 12 cases because of wound infection. Anatomical reduction or approximate anatomical reduction was achieved in all 12 cases. The patients were followed up 3-39 months (median, 18 months). No loosening of internal fixation or fracture displacement was observed during follow-up. The fracture healing time was 7-13 weeks (mean, 9.7 weeks). At last follow-up, according to the Matta standard, the outcome was excellent in 10 cases and good in 2 cases; according to Majeed score, the results were excellent in 9 cases, good in 1, and poor in 2. Early internal fixation operation of open Tile type C pelvic fractures can effectively restore the pelvic anatomical structure and stability, reduce the complication, and achieve satisfactory effectiveness.
Longo, F; Finotti, L; Bellini, L; Zavan, B; Busetto, R; Isola, M
2016-05-01
A 15-year-old female huacaya alpaca (Vicugna pacos) was referred because of a non-weight-bearing lameness (4/4) in the left pelvic limb caused by a grade three open metatarsal fracture. The referring veterinarian treated the fracture with conservative management using bandages, but it progressively evolved to a non-union. Clinical examination revealed external wounds on the medial and lateral surfaces of the metatarsus. Radiographs confirmed an open, nonarticular, displaced, diaphyseal fracture of the left metatarsus. Cancellous bone was sourced from bovine proximal and distal femur epiphyses, followed by a thermal shock procedure to achieve decellularisation, to produce a xenograft. Open reduction and internal fixation of the fracture using locking plates was performed. Alignment of the fracture fragments was corrected and the xenograft was placed at the debrided fracture site to stimulate and harness osteogenesis in situ. Clinical and radiographic follow-up was performed up to 40 weeks postoperatively. Clinical evaluations revealed that the alpaca gradually increased weight bearing following bandage removal 10 days after surgery. Serial radiographs showed correct alignment of the left metatarsus, progressive bone modelling and, complete bone union at 12 weeks. Ten months postoperatively the alpaca showed no signs of lameness and resumed normal activity. For management of a metatarsal non-union, a combination of bovine xenograft application and angular stable internal fixation progressed toward an excellent long-term recovery.
[Principles of management of periprosthetic fractures].
Röderer, G; Gebhard, F; Scola, A
2016-03-01
The increasing numbers of primary total hip and knee replacements have subsequently led to growing rates of periprosthetic fractures. In many cases geriatric patients with osteopenia or osteoporotic bone quality are affected. The goal of treatment is the retention or reconstruction of joint function using open reduction and internal fixation or a revision prosthesis. The aim of this article is a description of the basic principles of treatment of periprosthetic fractures of the lower extremities. An exact description of the fracture using current classification systems with imaging diagnostics is mandatory. This also includes an assessment of the stability of the prosthesis. In the case of a stable prosthesis and a good bone stock open reduction and internal fixation should be performed. In these cases locking plates are standard procedure. If fracture reduction is possible minimally invasive procedures can be performed which help to reduce the surgical trauma and accelerate rehabilitation. If the prosthesis is loose it has to be exchanged for a revision implant. If vast bony defects result they can be augmented using wedges. Conservative treatment plays only a subordinate role in selected cases. Periprosthetic fractures show an increasing incidence and occur more frequently in the geriatric patient population. Due to comorbidities and poor bone quality surgical treatment is a challenge. The fracture must be exactly classified using the appropriate classification system in order to clarify if the prosthesis can be retained or if it has to be exchanged.
Kozlov, V K; Akhmedov, B G; Chililov, A M
To increase an efficiency of complex treatment of patients with diaphyseal gunshot fractures of long bones by introduction of modern minimally invasive surgical techniques of internal osteosynthesis into clinical practice of civil health care and to improve the outcomes in victims. Prospective comparative clinical trial included 104 victims from the Republic of Yemen with gunshot wounds of limbs of various severity for the period 2009-2011. There were diaphyseal fractures of long bones of limbs associated with soft tissue injuries. Men were predominant (80.7%). Age ranged from 15 to 80 years (mean 38,5 ± 5,7 years). Various surgical techniques of simultaneous and staged treatment were used for gunshot fractures of long bones of limbs. Additional immune therapy was prescribed to prevent infectious complications in the most severe cases. Victims were comprehensively treated according to different staged treatment: conventional surgical treatment with external fixation devices or early primary minimally invasive functionally stable osteosynthesis with LCP/BIOS plates were applied for low-energy fractures; in case of high-energy fractures the first stage included external fixation devices deployment followed by their subsequent replacement during delayed minimally invasive osteosynthesis. The essence of improvement is pursuit to simultaneous minimally invasive surgery by using of current plates for osteosynthesis and preventive immunotherapy of immune dysfunction to eliminate infectious complications. As a result, we obtained 2-fold decrease of surgical invasiveness (r≤0,01) and hospital-stay (r≤0,01). Repeated osteosynthesis was not made. Also 4-fold and 40-fold reduction of infectious and noninfectious complications was observed. This management was accompanied by reduced rehabilitation tine and significantly improved quality of life. Improved technique and algorithm of complex treatment of diaphyseal gunshot fractures of long bones of limbs were described. Early minimally invasive functionally stable osteosynthesis with modern implants and non-specific immune prevention of infectious complications are more effective and economically justified compared with conventional treatment including external fixation devices without immunoactive therapy.
The effect of early operative stabilization on late displacement of zone I and II sacral fractures.
Emohare, Osa; Slinkard, Nathaniel; Lafferty, Paul; Vang, Sandy; Morgan, Robert
2013-02-01
This study was designed to evaluate the effect on displacement of early operative stabilization on unstable fractures when compared to stable fractures of the sacrum. Patient consisted of those sustaining traumatic pelvic fractures that also included sacral fractures of Denis type I and type II classification, who were over 18 at the time of the study. Patients were managed emergently, as judged appropriate at the time and then subsequently divided into two cohorts, comprising those who were either treated operatively or non-operatively. The operative group comprised those treated with either internal fixation or external fixation. Twenty-eight patients had zone II fractures, and 20 had zone I fractures. Zone II fractures showed average displacements of 6.5mm and 6.9mm in the rostral-caudal and anteroposterior directions, respectively, at final follow up. Zone I fractures had average displacements of 6.6mm and 6.1mm in both directions. There were no significant differences between zone I and II sacral fractures (rostral-caudal P=0.74, anteroposterior P=0.24). Average changes in fracture displacement in patients with zone I fractures were 0.6-1.0mm in both directions. Average changes in zone II fractures were 1.8-1.5mm in both directions. There were no significant differences between the average changes in zone I and II fractures in any direction (rostral-caudal P=0.64, anteroposterior P=0.68) or in average displacements at final follow up in any of zone or the entire cohort. Statistically significant differences were noted in average changes in displacement in zone II fractures in the anteroposterior plane (P=0.03) and the overall cohort in the anteroposterior plane (P=0.02). Operative fixation for unstable sacral fractures ensures displacement at follow up is comparable with stable fractures treated non operatively. Copyright © 2012 Elsevier Ltd. All rights reserved.
An Overview of Internal Fixation Implant Metallurgy and Galvanic Corrosion Effects.
Koh, Justin; Berger, Aaron; Benhaim, Prosper
2015-08-01
Orthopedic and hand surgery implants for internal fixation of fractures have evolved substantially over the past 50 years. Newer metal compositions have been used, and new standards have been applied to older alloys, resulting in modern implants with unique physical properties and better clinical performances. Conventional wisdom has long dictated that implanting different metals should be avoided, but few guidelines exist regarding the safety of using in proximity implant systems of dissimilar metals. To better characterize the landscape of internal fixation implant metallurgy, we have compiled the recommendations and conclusions of the currently available and pertinent literature. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Malcolm, James G; Tan, Lee A; Johnson, Andrew K
2017-07-20
A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature.
Galante, Vito N; Vicenti, Giovanni; Corina, Gianfranco; Mori, Claudio; Abate, Antonella; Picca, Girolamo; Conserva, Vito; Speciale, Domenico; Scialpi, Lorenzo; Tartaglia, Nicola; Caiaffa, Vincenzo; Moretti, Biagio
2016-10-01
To determine the efficacy of hybrid external fixation in the treatment of tibial pilon fractures. Retrospective, multicentre study. Adult patients with tibial pilon fractures treated with hybrid external fixation. Fracture reduction with ligamentotaxis and fixation with XCaliber hybrid external fixator. Fracture union, complications, functional outcome (Mazur Ankle Score). Union was obtained in 159 fractures at an average of 125days; there were three delayed unions and three non-unions. The most frequent complication was superficial pin-track infections (48), all of which responded to local wound care and antibiotics. There were no deep infections and no DVT. Only one fracture had loss of reduction that required frame revision. The overall functional scores were 91 (excellent) for AO/OTA type A fractures, 89 (good) for type B fractures, and 75 (satisfactory) for type C fractures. Hybrid external fixation is an effective method of stabilising tibial pilon fractures, particularly those with marked comminution. The minimally-invasive technique and stable fixation enable early mobilisation, with good functional results and minimal complications. Level IV Case series. Copyright © 2016 Elsevier Ltd. All rights reserved.
Design and Optimization of Resorbable Silk Internal Fixation Devices
NASA Astrophysics Data System (ADS)
Haas, Dylan S.
Limitations of current material options for internal fracture fixation devices have resulted in a large gap between user needs and hardware function. Metal systems offer robust mechanical strength and ease of implantation but require secondary surgery for removal and/or result in long-term complications (infection, palpability, sensitivity, etc.). Current resorbable devices eliminate the need for second surgery and long-term complications but are still associated with negative host response as well as limited functionality and more difficult implantation. There is a definitive need for orthopedic hardware that is mechanically capable of immediate fracture stabilization and fracture fixation during healing, can safely biodegrade while allowing complete bone remodeling, can be resterilized for reuse, and is easily implantable (self-tapping). Previous work investigated the use of silk protein to produce resorbable orthopedic hardware for non- load bearing fracture fixation. In this study, silk orthopedic hardware was further investigated and optimized in order to better understand the ability of silk as a fracture fixation system and more closely meet the unfulfilled market needs. Solvent-based and aqueous-based silk processing formulations were cross-linked with methanol to induce beta sheet structure, dried, autoclaved and then machined to the desired device/geometry. Silk hardware was evaluated for dry, hydrated and fatigued (cyclic) mechanical properties, in vitro degradation, resterilization, functionalization with osteoinductive molecules and implantation technique for fracture fixation. Mechanical strength showed minor improvements from previous results, but remains comparable to current resorbable fixation systems with the advantages of self-tapping ability for ease of implantation, full degradation in 10 months, ability to be resterilized and reused, and ability to release molecules for osteoinudction. In vivo assessment confirmed biocompatibility, showed improved bone deposition and remodeling with functionalization and showed promising feasibility of fracture fixations with minor adjustments to geometry. The proposed silk orthopedic hardware exhibits high potential as a resorbable fixation system that can bridge the gap between the current materials for internal fixation devices.
Dorsal Plating of Unstable Scaphoid Fractures and Nonunions.
Bain, Gregory I; Turow, Arthur; Phadnis, Joideep
2015-09-01
Achieving stable fixation of displaced acute and chronic nonunited scaphoid fractures continues to be a challenge for the treating surgeon. The threaded compression screw has been the mainstay of treatment of these fractures for the last 3 decades; however, persistent nonunion after screw fixation has prompted development of new techniques. Recent results of volar buttress plating have been promising. We describe a novel technique of dorsal scaphoid plating. In contrast to volar plating, the dorsal plate is biomechanically more favorable as it utilizes the tension side of the scaphoid bone for dynamic compression. Dorsal scaphoid plating provides a more stable construct than the traditional Herbert screw and mitigates the need for vascular or corticocancellous bone grafting in most cases.
Liu, Xi; Cen, Shiqiang; Xiang, Zhou; Zhong, Gang; Yi, Min; Fang, Yue; Liu, Lei; Huang, Fuguo
2017-06-01
To evaluate the safety of conversion from external fixation to internal fixation for open tibia fractures. Between January 2010 and December 2014, 94 patients (98 limbs) with open tibia fractures were initially treated with external fixators at the first stage, and the clinical data were retrospectively analyzed. In 29 cases (31 limbs), the external fixators were changed to internal fixation for discomfort, pin tract response, Schantz pin loosening, delayed union or non-union after complete wound healing and normal or close to normal levels of erythrocyte sedimentation rate (ESR), C reactive protein (CRP), and the leucocyte count as well as the neutrophil ratio (trial group); in 65 cases (67 limbs), the external fixators were used as the ultimate treatment in the control group. There was no significant difference in gender, age, side of the limbs, interval from injury to the first debridement, initial pathogenic bacteria, the limbs that skin grafting or flap transferring for skin and soft tissue defect between the two groups ( P >0.05). The incidence of Gustilo type III fractures in the control group was significantly higher than that in the trial group ( P =0.000). The overall incidence of infection was calculated respectively in the two groups. The incidence of infection according to different fracture types and whether skin grafting or flap transferring was compared between the two groups. The information of the pathogenic bacteria was recorded in the infected patients, and it was compared with the results of the initial culture. The incidence of infection in the patients of the trial group using different internal fixation instruments was recorded. The overall incidences of infection for the trial and control groups were 9.7% (3/31) and 9.0% (6/67) respectively, showing no significant difference ( χ 2 =0.013, P =0.909). No infection occurred in Gustilo type I and type II patients. The incidence of infection for Gustilo type IIIA patients in the trial group and the control group were 14.3% (1/7) and 6.3% (2/32) respectively, showing no significant difference ( χ 2 =0.509, P =0.476); the incidence of infection for type IIIB patients in the two groups were 50.0% (2/4) and 14.3% (2/14) respectively, showing no significant difference ( χ 2 =2.168, P =0.141); and the incidence of infection for type IIIC patients in the two groups were 0 and 16.7% (2/12) respectively, showing no significant difference ( χ 2 =0.361, P =0.548). Of all the infected limbs, only 1 limb in the trial group had the same Staphylococcus Aureus as the result of the initial culture. In the patients who underwent skin grafting or flap transferring, the incidence of infection in the trial and control groups were 33.3% (2/6) and 13.3% (2/15) respectively, showing no significant difference ( χ 2 =1.059, P =0.303). After conversion to internal fixation, no infection occurred in the cases that fixed with nails (11 limbs), and infection occurred in 4 of 20 limbs that fixed with plates, with an incidence of infection of 20%. Conversion from external fixation to internal fixation for open tibia fractures is safe in most cases. However, for open tibia fractures with extensive and severe soft tissue injury, especially Gustilo type III patients who achieved wound heal after flap transfer or skin grafting, the choice of secondary conversion to internal fixation should carried out cautiously. Careful pre-operative evaluation of soft tissue status, cautious choice of fixation instrument and meticulous intra-operative soft tissue protection are essential for its safety.
Anterior subcutaneous internal fixation for treatment of unstable pelvic fractures
2014-01-01
Background Fractures of the pelvic ring including disruption of the posterior elements in high-energy trauma have both high morbidity and mortality rates. For some injury pattern part of the initial resuscitation includes either external fixation or plate fixation to close the pelvic ring and decrease blood loss. In certain situations – especially when associated with abdominal trauma and the need to perform laparotomies – both techniques may put the patient at risk of either pintract or deep plate infections. We describe an operative approach to percutaneously close and stabilize the pelvic ring using spinal implants as an internal fixator and report the results in a small series of patients treated with this technique during the resuscitation phase. Findings Four patients were treated by subcutaneous placement of an internal fixator. Screw fixation was carried out by minimally invasive placement of two supra-acetabular iliac screws. Afterwards, a subcutaneous transfixation rod was inserted and attached to the screws after reduction of the pelvic ring. All patients were allowed to fully weight-bear. No losses of reduction or deep infections occurred. Fracture healing was uneventful in all cases. Conclusion Minimally invasive fixation is an alternative technique to stabilize the pelvic ring. The clinical results illustrate that this technique is able to achieve good results in terms of maintenance of reduction the pelvic ring. Also, abdominal surgeries no longer put the patient at risk of infected pins or plates. PMID:24606833
Stable fixation with absorbable sutures in craniofacial surgery.
Linz, C; Kunz, F; Krauß, J; Böhm, H; Wirth, C; Hartmann, S; Wirbelauer, J; Schweitzer, T
2016-05-01
The present study analyses the exclusive use of absorbable suture material (Vicryl(®), Ethicon, Germany) in the fixation of transposed bone segments in craniofacial surgery without modification of the osteotomy design. Among 129 children up to 24 months of age, osteosynthesis was conducted exclusively with Vicryl(®) sutures. The stability of postoperative results was evaluated and possible foreign body reactions were examined within the framework of clinical and radiological routine checks. All examined children exhibited stable postoperative conditions while the length of hospital stay was not affected. X-ray examinations of the skull in two planes demonstrated good bony union in all cases. Relevant foreign body reactions were not observed. The exclusive application of absorbable suture material enables stable and cost effective osteosynthesis. Significant foreign body reactions were not observed. The exclusive use of absorbable sutures did not alter the osteotomy design. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J
2013-08-01
The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.
Chess, David G.; Grainger, R. Wayne; Phillips, Tom; Zarzour, Zane D.; Sheppard, Bruce R.
1996-01-01
Objective To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty. Design A clinical and radiographic review. Setting A tertiary lower limb joint replacement centre. Patients Two hundred and twenty-one patients with noninflammatory gonarthrosis. Interventions Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons. Main Outcome Measures Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill. Results Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases. Conclusion The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. PMID:8857987
Salvage of infected total knee fusion: the last option.
Wiedel, Jerome D
2002-11-01
Currently the most common indication for an arthrodesis of the knee is a failed infected total knee prosthesis. Other causes of a failed total knee replacement that might necessitate a knee fusion include aseptic loosening, deficient extensor mechanism, poor soft tissues, and Charcot joint. Techniques available for achieving a knee fusion are external fixation and internal fixation methods. The external fixation compression devices have been the most widely used for knee fusion and have been successful until the indications for fusion changed to mostly failed prosthetic knee replacement. With failed total knee replacement, the problem of severe bone loss became an issue, and the external fixation compression devices, even including the biplane external fixators, have been the least successful method reported for gaining fusion. The Ilizarov technique has been shown to achieve rigid fixation despite this bone loss, and a review of reports are showing high fusion rates using this method. Internal fixation methods including plate fixation and intramedullary nails have had the best success in gaining fusion in the face of this bone loss and have replaced external fixation methods as the technique of choice for knee fusion when severe bone loss is present. A review of the literature and a discussion of different fusion techniques are presented including a discussion of the influence that infection has on the success of fusion.
Wannicke, Nicola; Liskow, Iris; Voss, Maren
2010-09-01
During two independent cruises in the north-eastern tropical Atlantic Ocean, we applied two different approaches to investigate the impact of diazotrophy on nitrogen stable isotope signatures in nitrate and particulate organic nitrogen (PON) of the food-web constituents. The first approach, used during the Poseidon cruise 348 in the Mauritanian upwelling, investigated the long-term influence of diazotrophy on the natural abundance of δ(15)N-NO(-)(3) and PON. The second approach, adopted during the Cape Verde field cruise, applied stable isotope tracer addition experiments. These served to determine the instantaneous transfer of diazotrophic N to the higher trophic level. Both approaches showed that N(2) fixation was compatible with the pattern and the magnitude of the isotopic depletion of dissolved NO(-)(3) during the Mauritanian upwelling cruise, as well as PON in zooplankton and phytoplankton during the Cape Verde cruises. An N-budget using (15)N incorporation rates and diazotrophic N(2) fixation rates showed that 6 % of the daily N(2) fixation was potentially taken up by the mesozooplankton community. Direct grazing accounted for 56 % of gross mesozooplanktonic N incorporation, while 46 % occurred due to channelling through the microbial loop.
Duriez, P; Devaux, T; Chantelot, C; Baudrier, N; Hery, J-Y; Mainard, D; Favier, T; Massin, P
2016-10-01
Although internal fixation is the reference treatment for extracapsular fracture of the upper femur, indications for arthroplasty are broadening, especially in unstable comminutive fracture in fragile bone. The present study hypothesis was that arthroplasty reduces early mortality and morbidity and provides better recovery of autonomy in over-80 year-old patients than does internal fixation. A prospective multicenter study was conducted on 8 sites. Internal fixation was systematically used in 5 centers; arthroplasty was used systematically in 1 center, and reserved for unstable fracture in 2 centers. A total of 697 patients aged over 80 years (mean age, 85±5 years), presenting with extracapsular fracture, were included; 521 were treated by internal fixation and 176 by arthroplasty. Results were studied on multivariate analysis of ASA score, blood loss, transfusion, and also of treatment modality as an independent factor for early (first 6 months) mortality and morbidity (mechanical, general and nutritional complications) and functional outcome (autonomy and dependence). Overall mortality was 19.2%. Autonomy deteriorated in 56% of patients alive at 6 months and dependence worsened in 44%. Two percent of those managed by internal fixation underwent revision for disassembly (n=8) or infection (n=1). Eight percent of those managed by arthroplasty underwent revision for dislocation (n=4), implant loosening (n=3) or infection (n=7). On univariate analysis, mortality was higher in the arthroplasty group (25%) than with internal fixation (17%; P=0.002), as were blood loss (425±286mL versus 333±223mL; P<0.0001), transfusion rate (61% versus 32%; P<0.0001) and infection (4% versus 0.2%; P<0.001). On multivariate analysis, however, treatment modality no longer showed impact on mortality or on morbidity and autonomy at 6 months. Nutritional status was better conserved at 6 months following arthroplasty, but dependence worsened. Poor preoperative autonomy, ASA score, and nutritional status and time to treatment were independent factors for mortality. Transfusion, associated with onset of mechanical complications, significantly increased dependence. Type of treatment had little impact on mortality, morbidity or functional outcome. Differences seemed more related to preoperative functional and nutritional status. III, prospective case-control study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Eye movement-invariant representations in the human visual system.
Nishimoto, Shinji; Huth, Alexander G; Bilenko, Natalia Y; Gallant, Jack L
2017-01-01
During natural vision, humans make frequent eye movements but perceive a stable visual world. It is therefore likely that the human visual system contains representations of the visual world that are invariant to eye movements. Here we present an experiment designed to identify visual areas that might contain eye-movement-invariant representations. We used functional MRI to record brain activity from four human subjects who watched natural movies. In one condition subjects were required to fixate steadily, and in the other they were allowed to freely make voluntary eye movements. The movies used in each condition were identical. We reasoned that the brain activity recorded in a visual area that is invariant to eye movement should be similar under fixation and free viewing conditions. In contrast, activity in a visual area that is sensitive to eye movement should differ between fixation and free viewing. We therefore measured the similarity of brain activity across repeated presentations of the same movie within the fixation condition, and separately between the fixation and free viewing conditions. The ratio of these measures was used to determine which brain areas are most likely to contain eye movement-invariant representations. We found that voxels located in early visual areas are strongly affected by eye movements, while voxels in ventral temporal areas are only weakly affected by eye movements. These results suggest that the ventral temporal visual areas contain a stable representation of the visual world that is invariant to eye movements made during natural vision.
Malcolm, James G; Johnson, Andrew K
2017-01-01
A sagittal split fracture of the C1 lateral mass is an unstable subtype of C1 fractures and has a high propensity for developing late deformities and pain with nonoperative management. A primary internal fixation of this type of fracture has been recently described with good clinical outcomes and preservation of motion. We present a modified technique of primary internal fixation using an obliquely inserted C1 lag screw with imaging guidance. We successfully treated a 55-year-old woman with a unilateral C1 oblique sagittal split fracture who failed nonoperative management. Technical nuances are discussed with a review of pertinent literature. PMID:28948116
Scapular thickness--implications for fracture fixation.
Burke, Charity S; Roberts, Craig S; Nyland, John A; Radmacher, Paula G; Acland, Robert D; Voor, Michael J
2006-01-01
The purpose of this study was to measure and map scapula osseous thickness to identify the optimal areas for internal fixation. Eighteen (9 pairs) scapulae from 2 female and 7 male cadavers were used. After harvest and removal of all soft tissues, standardized measurement lines were made based on anatomic landmarks. For consistency among scapulae, measurements were taken at standard percentage intervals along each line approximating the distance between two consecutive reconstruction plate screw holes. Two-mm-diameter drill holes were made at each point, and a standard depth gauge was used to measure thickness. The glenoid fossa (25 mm) displayed the greatest mean osseous thickness, followed by the lateral scapular border (9.7 mm), the scapula spine (8.3 mm), and the central portion of the body of the scapula (3.0 mm). To optimize screw purchase and internal fixation strength, the lateral border, the lateral aspect of the base of the scapula spine, and the scapula spine itself should be used for anatomic sites of internal fixation of scapula fractures.
Hao, Yinglu; Li, Yanping; Liao, Derong; Yang, Ling; Liu, Fangyan
2017-03-01
Data comparing active atrial lead fixation with passive atrial lead fixation in Chinese patients with cardiovascular implantable electronic devices (CIEDs) for atrial pacing is limited. Our study evaluated the effectiveness of active fixation versus passive fixation of atrial leads by observing the lead performance parameters. This retrospective, long-term, single-center study included a cohort of Chinese patients who underwent CIED implantation at the Department of Cardiology of People's Hospital of Yuxi City, China, from 1 March 2010 to 1 March 2015. Efficacy was determined by comparing implantation time, threshold values, incidence of lead dislocation/failure, and lead-related complications between the two groups. Of the 1217 patients, active and passive atrial lead fixation were performed in 530 (mean age, 69.37 ± 11.44 years) and 497 (mean age, 68.33 ± 10.96 years). The active fixation group reported significantly lower mean atrial implantation times (P = .0001) and threshold values (P = .044) compared with the passive atrial lead fixation group. In addition, threshold values in the active atrial lead fixation group were stable throughout the observation period. No instances of myocardial perforation, cardiac tamponade, implantation failure, or electrode dislocation/re-fixation were reported in the active atrial lead fixation group. A favorable decrease in patient comfort parameters such as bed rest time (P = .027) and duration of hospital stay (P = .038) were also observed in the active lead fixation group. Active atrial lead fixation demonstrated greater stability, steady long-term thresholds and minimal lead-related complications compared to passive lead fixation in Chinese patients with CIEDs.
Li, C-L
2014-01-01
To investigate clinical efficacy of unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. 64 patients with unstable pelvic fractures were selected in the hospital from January 2008 to June 2011, and were randomly divided into two groups.(32 patients with sacroiliac anterior plate fixation as the control group, and another 32 patients with percutaneous sacroiliac screw internal fixation as the observation group). The perioperative period clinical indicators, postoperative Matta score, postoperative Majeed function score of all patients were compared and analyzed. The operation time, intraoperative blood loss, wound total length, postoperative fever time, duration of hospitalization in the observation group were significantly less than those in the control group. The complication rate (3.1%) in the observation group was lower than that in the control group (21.9%). The rate of Matta score excellent (96.9%) in the observation group was higher than that in the control group (81.2%) after the treatment. The rate of Majeed function score excellent (93.8%) in the observation group was significantly higher than that in the control group (75%) after the treatment. Percutaneous sacroiliac screw internal fixation in the treatment of unstable pelvic fractures has less injury, less bleeding, less pain and rapid recovery which is a safe and effective minimally invasive operation method. The clinical curative effect of percutaneous sacroiliac screw internal fixation is better than anterior plate fixation for the treatment of sacroiliac joint. The full preparation before the surgery and patients with positive can substantially reduce the occurrence of complications rate.
Releasing the circumferential fixation of the medial meniscus does not affect its kinematics.
Vrancken, A C T; van Tienen, T G; Hannink, G; Janssen, D; Verdonschot, N; Buma, P
2014-12-01
Meniscal functioning depends on the fixation between the meniscal horns and the surrounding tissues. It is unknown, however, whether the integration between the outer circumference of the medial meniscus and the knee capsule/medial collateral ligament also influences the biomechanical behavior of the meniscus. Therefore, we aimed to determine whether detaching and resuturing the circumferential fixation of the medial meniscus influence its kinematic pattern. Human cadaveric knee joints were flexed (0°-30°-60°-90°) in a knee loading rig, in neutral orientation and under internal and external tibial torques. Roentgen stereophotogrammetric analysis was used to determine the motion of the meniscus in anteroposterior (AP) and mediolateral (ML) directions. Three fixation conditions were evaluated: (I) intact, (II) detached and (III) resutured. Detaching and resuturing the circumferential fixation did not alter the meniscal motion pattern in either the AP or ML direction. Applying an additional internal tibial torque caused the medial meniscus to move slightly anteriorly, and an external torque caused a little posterior translation with respect to the neutral situation. These patterns did not change when the circumferential fixation condition was altered. This study demonstrated that the motion pattern of the medial meniscus is independent of its fixation to the knee capsule and medial collateral ligament. The outcomes of this study can be deployed to design the fixation strategy of a permanent meniscus prosthesis. As peripheral fixation is a complicated step during meniscal replacement, the surgical procedure is considerably simplified when non-resorbable implants do not require circumferential fixation. Copyright © 2014 Elsevier B.V. All rights reserved.
Rate of avascular necrosis and time to surgery in proximal humerus fractures.
Archer, L A; Furey, A
2016-12-01
Avascular necrosis (AVN) of the humeral head is a devastating complication of proximal humeral fracture (PHF) that often results in long-term morbidity for the patient. Rates of AVN depend on the number of fracture fragments and are highly variable. The literature suggests that timely stable and anatomic reduction may decrease the rate at which AVN develops after PHF. To our knowledge, there is no literature published investigating a temporal relationship between the timing of PHF fixation and rates of AVN. Operative records of one orthopedic trauma surgeon were used to identify patients that underwent open reduction internal fixation for PHF at our institution between 2007 and 2012. Radiographs at presentation were reviewed and used to classify the fractures into two, three or four parts. Date and time of the initial radiograph were recorded as were the date and time of available intra-operative fluoroscopic images. The time from presentation radiograph to operative fixation was calculated (hours). Available follow-up plain films were then reviewed and evaluated for the presence or absence of humeral head AVN. Time to surgery (less than or greater than 72 h) and patient age did not correlate with development of AVN after PHF (p > 0.26). Notably, the number of fracture fragments did influence the rate of AVN identified in patients with PHF (p = 0.002). Early operative intervention does not appear to decrease the rate of development of avascular necrosis after PHF.
Internal fixators: a safe option for managing distal femur fractures?
Batista, Bruno Bellaguarda; Salim, Rodrigo; Paccola, Cleber Antonio Jansen; Kfuri, Mauricio
2014-01-01
OBJECTIVE: Evaluate safety and reliability of internal fixator for the treatment of intra-articular and periarticular distal femur fractures. METHODS: Retrospective data evaluation of 28 patients with 29 fractures fixed with internal fixator was performed. There was a predominance of male patients (53.5%), with 52% of open wound fractures, 76% of AO33C type fractures, and a mean follow up of 21.3 months. Time of fracture healing, mechanical axis deviation, rate of infection and postoperative complications were registered. RESULTS: Healing rate was 93% in this sample, with an average time of 5.5 months. Twenty-seven percent of patients ended up with mechanical axis deviation, mostly resulting from poor primary intra-operative reduction. There were two cases of implant loosening; two implant breakage, and three patients presented stiff knee. No case of infection was observed. Healing rate in this study was comparable with current literature; there was a high degree of angular deviation, especially in the coronal plane. CONCLUSION: Internal fixators are a breakthrough in the treatment of knee fractures, but its use does not preclude application of principles of anatomical articular reduction and mechanical axis restoration. Level of Evidence II, Retrospective Study. PMID:25061424
Prudnikova, Oksana G; Shchurova, Elena N
2018-02-01
There is high risk of neurologic complications in one-stage management of severe rigid spinal deformities in adolescents. Therefore, gradual spine stretching variants are applied. One of them is the use of external transpedicular fixation. Our aim was to retrospectively study the outcomes of gradual correction with an apparatus for external transpedicular fixation followed by internal fixation used for high-grade kyphoscoliosis in adolescents. Twenty five patients were reviewed (mean age, 15.1 ± 0.4 years). Correction was performed in two stages: 1) gradual controlled correction with the apparatus for external transpedicular fixation; and 2) internal posterior transpedicular fixation. Rigid deformities in eight patients required discapophysectomy. Clinical and radiographic study of the outcomes was conducted immediately after treatment and at a mean long-term period of 3.8 ± 0.4 years. Pain was evaluated using the visual analogue scale (VAS, 10 points). The Oswestry questionnaire (ODI scale) was used for functional assessment. Deformity correction with the external apparatus was 64.2 ± 4.6% in the main curve and 60.7 ± 3.7% in the compensatory one. It was 72.8 ± 4.1% and 66.2 ± 5.3% immediately after treatment and 70.8 ± 4.6% and 64.3 ± 4.2% at long term, respectively. Pain relieved by 33.2 ± 4.2% (p < 0.05) immediately after treatment and by 55.6 ± 2.8% (p < 0.05) at long term. ODI reduced by 30.2 ± 1.7% (p < 0.05) immediately after treatment and by 37.2 ± 1.6% (p < 0.05) at long term. The apparatus for external transpedicular fixation provides gradual controlled correction for high-grade kyphoscoliosis in adolescents. Transition to internal fixation preserves the correction achieved, and correction is maintained at long term.
[Surgical strategy for upper cervical vertebrae instability through the anterior approach].
Huang, Wei-bing; Cai, Xian-hua; Chen, Zhuang-hong; Huang, Ji-feng; Liu, Xi-ming; Wei, Shi-jun
2013-07-01
To explore the choice and effect of internal fixation in treating upper cervical vertebrae instability through anterior approach. From March 2000 to September 2010,83 patients with upper cervical vertebrae instability were treated with internal fixation through anterior approach. There were 59 males and 24 females with a mean age of 42 years old (ranged, 20 to 68). Among these patients, 36 patients were treated with odontoid screw fixation, 16 patients with C1,2 transarticular screw fixation, 23 patients with C2,3 steel plate fixation, 5 patients with odontoid screw and transarticular screw fixation,2 patients with odontoid screw and C2.3 steel plate fixation, 1 patient with C1,2 transarticular screw and C2,3 steel plate fixation. One patient with completely cervical vertebrae cord injury died of pulmonary infection after C1,2 transarticular screw fixation. Other patients were followed up from 8 to 36 months with an average of 15 months. Upper cervical vertebrae stability were restored without vertebral artery and spinal cord injury. Thirty-six patients were treated with odontoid screw fixation and 5 patients were treated with screw combined with transarticular screw fixation obtained bone union in the dentations without bone graft. Among the 16 patients treated with C1,2 transarticular screw fixation, 13 patients obtained bone union after bone graft; 1 patient died of pulmonary infection after surgery; 1 patient with comminuted odontoid fracture of type II C and atlantoaxial anterior dislocation did not obtain bone union after bone graft,but the fibrous healing was strong enough to maintain the atlantoaixal joint stability; 1 patient with obsolete atlantoaxial anterior dislocation were re-treated with Brooks stainless steel wire fixation and bone graft through posterior approach, and finally obtained bone union. It could obtain satisfactory effects depending on the difference of cervical vertebrae instability to choose the correctly surgical method.
Posterior cervical fixation for fracture and degenerative disc disease.
An, H S; Coppes, M A
1997-02-01
There are numerous newer techniques that have been developed for the internal fixation of the cervical spine in recent years. Wiring techniques are still appropriate for posterior stabilization of the cervical spine. The halo vest is still widely used for the conservative management of cervical fractures and for postoperative external immobilization. The authors stress that the surgical indications for more modern rigid implants should be adhered to strictly. These implants also should be selected by weighing their advantages versus potential risks. In the upper cervical spine, the surgeon may choose traditional wiring methods and newer C1-C2 screw fixation, occipitocervical plate fixation. For the lower cervical spine, triple wiring technique or lateral mass plating may be used. The surgeon must choose an appropriate device based on the mechanism of injury, pathoanatomy of the lesion, and familiarity with the device, keeping in mind that the goals of internal fixation are stabilization, reduction and maintenance of alignment, early rehabilitation and perhaps enhancement of fusion rates, and avoidance of use of an external halo vest.
NASA Astrophysics Data System (ADS)
Widner, B.; Mulholland, M. R.; Bernhardt, P. W.; Chang, B. X.; Jayakumar, A.
2016-02-01
Recent work suggests that planktonic diazotrophs are geographically more widely distributed than previously thought including relatively warm (14-23oC) aphotic oxygenated pelagic waters and in aphotic waters within oxygen deficient zones. Because the volume of aphotic water in the ocean is large and may increase in the future, if dinitrogen (N2) fixation is widely occurring at sub-euphotic depths, this could result in a dramatic upward revision of global nitrogen (N) inputs via this process. N2 fixation rates were measured during a cruise in the Eastern Tropical South Pacific using stable isotope tracer techniques that account for slow gas dissolution. Results are compared with light, nutrient, and oxygen gradients (and necessarily temperature gradients). In addition, rates of N2 fixation made in vertical profiles within and above oxygen deficient waters are compared with those measured in vertical profiles adjacent to oxygen deficient waters. Results suggest that while rates of N2 fixation were measurable in deeper anoxic waters, volumetric N2 fixation rates were higher in surface waters.
Chen, Xue-Qiang; Wu, Qun-Feng; Dong, Wei-Qin; Yu, Li-Xin; Li, Xiong-Feng
2018-03-25
To explore clinical effect of modified Chevron osteotomy combined with lateral tissue loosening for the treatment of mild-moderate hallux valgus through internal signal approach. From July 2015 to June 2016, 26 patients with mild-moderate hallux valgus treated with modified Chevron osteotomy combined with lateral tissue loosening through internal signal approach, including 2 males and 24 females aged from 45 to 65 years old with an average of(54.6±4.8) years old;the courses of diseases ranged from 1 to 5 months with an average of (7.5±3.3) months. Hallux valgus angle(HVA), inter metatarsal angle(IMA) were measured at 12 months after operation, and AOFAS score was applied to evaluate clinical effect before and after operation. All incisions were healed at stage I. No incision occurred infection, metatarsal necrosis and recurrence of hallux valgus deformity. Two patients occurred skin numbness caused by musculocutaneous nerve injury. Twenty-six patients were followed up from 6 to 12 months with an average of(9.12±2.06) months. HVA, IMA were(30.01±3.71)°, (14.00±1.50)° before operation and(9.41±4.16)°, (7.00±0.60)° after operation, which had significant difference. There was statistical significance in AOFAS score before operation 54.77±9.59 and after operation 92.73±5.47, and 19 cases obtained excellent results and 7 moderate. Modified Chevron osteotomy combined with full thread headless pressure screw fixation and lateral tissue loosening for the treatment of mild-moderate hallux valgus has advantages of excellent exposure, simple operation, stable fixation, rapid recovery. Akin osteotomy with internal capsulorrhaphy were used with lateral loosening and could recover soft tissue balance between lateral and internal, and could receive satisfied clinical effects. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.
Bonne, Stephanie L; Turnbull, Isaiah R; Southard, Robert E
2015-06-01
Internal fixation of the ribs has been shown in numerous studies to decrease complications following traumatic rib fractures. Anterior injuries to the chest wall causing cartilaginous fractures, although rare, can cause significant disability and can lead to a variety of complications and, therefore, pose a unique clinical problem. Here, we report the surgical technique used for four patients with internal fixation of injuries to the cartilaginous portions of the chest wall treated at our center. All patients had excellent clinical outcomes and reported improvement in symptoms, with no associated complications. Patients who have injuries to the anterior portions of the chest wall should be considered for internal fixation of the chest wall when the injuries are severe and can lead to clinical disability.
Ono, Hiroshi; Furuta, Kazuhiko; Fujitani, Ryotaro; Katayama, Takeshi; Akahane, Manabu
2010-07-01
The purpose of this study was to assess articular surface reduction arthroscopically after volar locked-plate fixation of distal radius fractures (DRFs) via fluoroscopyguided open reduction/internal fixation. We also aimed to develop preoperative radiographic criteria to help assist in determining which DRFs may need arthroscopic evaluation. A total of 31 consecutive patients with DRF were prospectively enrolled. Posteroanterior (PA) and lateral radiographs as well as axial, coronal, and sagittal CT scans were obtained just after attempted reduction of the DRF. The widest articular displacement at the radiocarpal joint surface of the distal radius (preopD) was then measured using a digital radiography imaging system. The DRF was reduced under fluoroscopy, and a volar locked plate was applied. The degree of residual articular displacement was then measured arthroscopically, and the maximum displacement (postopD) was measured with a calibrated probe. Of the 31 patients, 7 had an arthroscopically assessed maximum postopD of > or = 2 mm after internal fixation. The correlation coefficients between each preopD and postopD of all radiographs and CTs were statistically significant. The cutoff values were 0.5 mm for PA radiographs, 2.10 mm for lateral radiographs, 2.15 mm for axial CT scans, 3.15 mm for coronal CT scans, and 1.20 mm for sagittal CT scans. All cutoff values for PA and lateral radiographs and for axial, coronal, and sagittal CT scans were unsuitable as screening criteria for arthroscopic reduction of DRF because of their low sensitivities and specificities. The cutoff value of the new preopD (the sum of the preopDs determined by lateral radiography and coronal CT scan) was 5.80 mm, and its sensitivity and specificity were 100% and 83.3%, respectively. Because a new preopD cutoff value of 5.80 mm is a good indicator for residual articular displacement after internal fixation of >2 mm, it is also a good indicator for the need for arthroscopic evaluation after internal fixation.
Kwiatkowska, Maria; Stępiński, Dariusz; Polit, Justyna T; Popłońska, Katarzyna; Wojtczak, Agnieszka
2011-01-01
Lipotubuloids, structures containing lipid bodies and microtubules, are described in ovary epidermal cells of Ornithogalum umbellatum. Microtubules of lipotubuloids can be fixed in electron microscope fixative containing only buffered OsO(4) or in glutaraldehyde with OsO(4) post-fixation, or in a mixture of OsO(4) and glutaraldehyde. None of these substances fixes cortical microtubules of ovary epidermis of this plant which is characterized by dynamic longitudinal growth. However, cortical microtubules can be fixed with cold methanol according immunocytological methods with the use of β-tubulin antibodies and fluorescein. The existence of cortical microtubules has also been evidenced by EM observations solely after the use of taxol, microtubule stabilizer, and fixation in a glutaraldehyde/OsO(4) mixture. These microtubules mostly lie transversely, sometimes obliquely, and rarely parallel to the cell axis. Staining, using Ruthenium Red and silver hexamine, has revealed that lipotubuloid microtubules surface is covered with polysaccharides. The presumption has been made that the presence of a polysaccharide layer enhances the stability of lipotubuloid microtubules.
Fixation of osteoporotic fractures in the upper limb with a locking compression plate.
Neuhaus, V; King, J D; Jupiter, J B
2012-01-01
Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques. Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.
Hsu, Andrew R; Szatkowski, Jan P
2015-06-01
Management of severely comminuted, complete articular tibial pilon fractures (AO/OTA 43-C) remains a challenge, with few treatment options providing good clinical outcomes. Open reduction and internal fixation of the tibial plafond, tibiotalar arthrodesis, and salvage hindfoot reconstruction procedures are all associated with surgical complications and functional limitations. In this report, we present a case of a complex pilon fracture in a patient with multiple medical comorbidities and socioeconomic disadvantages that was successfully and acutely treated with a retrograde tibiotalocalcaneal hindfoot arthrodesis nail. At final follow-up examination, the patient had decreased pain, a stable plantigrade foot, and could ambulate with normal shoes without any assistive devices. Therapeutic, Level IV: Case series. © 2014 The Author(s).
Chemosynthetic symbionts of marine invertebrate animals are capable of nitrogen fixation.
Petersen, Jillian M; Kemper, Anna; Gruber-Vodicka, Harald; Cardini, Ulisse; van der Geest, Matthijs; Kleiner, Manuel; Bulgheresi, Silvia; Mußmann, Marc; Herbold, Craig; Seah, Brandon K B; Antony, Chakkiath Paul; Liu, Dan; Belitz, Alexandra; Weber, Miriam
2016-10-24
Chemosynthetic symbioses are partnerships between invertebrate animals and chemosynthetic bacteria. The latter are the primary producers, providing most of the organic carbon needed for the animal host's nutrition. We sequenced genomes of the chemosynthetic symbionts from the lucinid bivalve Loripes lucinalis and the stilbonematid nematode Laxus oneistus. The symbionts of both host species encoded nitrogen fixation genes. This is remarkable as no marine chemosynthetic symbiont was previously known to be capable of nitrogen fixation. We detected nitrogenase expression by the symbionts of lucinid clams at the transcriptomic and proteomic level. Mean stable nitrogen isotope values of Loripes lucinalis were within the range expected for fixed atmospheric nitrogen, further suggesting active nitrogen fixation by the symbionts. The ability to fix nitrogen may be widespread among chemosynthetic symbioses in oligotrophic habitats, where nitrogen availability often limits primary productivity.
An approximate model for cancellous bone screw fixation.
Brown, C J; Sinclair, R A; Day, A; Hess, B; Procter, P
2013-04-01
This paper presents a finite element (FE) model to identify parameters that affect the performance of an improved cancellous bone screw fixation technique, and hence potentially improve fracture treatment. In cancellous bone of low apparent density, it can be difficult to achieve adequate screw fixation and hence provide stable fracture fixation that enables bone healing. Data from predictive FE models indicate that cements can have a significant potential to improve screw holding power in cancellous bone. These FE models are used to demonstrate the key parameters that determine pull-out strength in a variety of screw, bone and cement set-ups, and to compare the effectiveness of different configurations. The paper concludes that significant advantages, up to an order of magnitude, in screw pull-out strength in cancellous bone might be gained by the appropriate use of a currently approved calcium phosphate cement.
Operative Fixation of Rib Fractures Indications, Techniques, and Outcomes.
Galos, David; Taylor, Benjamin; McLaurin, Toni
2017-01-01
Rib fractures are extremely common injuries and vary in there severity from single nondisplaced fractures to multiple segmental fractures resulting in flail chest and respiratory compromise. Historically, rib fractures have been treated conservatively with pain control and respiratory therapy. However this method may not be the best treatment modality in all situations. Operative fixation of select rib fractures has been increasing in popularity especially in patients with flail chest and respiratory compromise. Newer techniques use muscle sparing approaches and precontoured locking plate technology to obtain stable fixation and allow improved respiration. Current reports shows that rib fracture fixation offers the benefits of improved respiratory mechanics and improved pain control in the severe chest wall injury with resultant improvement in patient outcomes by decreasing time on the ventilator, time in the intensive care unit, and overall hospital length of stay.
Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki
2015-12-07
In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.
An orthopedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views
Chua, David; Jaglal, Susan B.; Schatzker, Joseph
1997-01-01
Objective To examine the reasons for practice variation in the treatment of displaced femoral neck fractures. Design A survey, asking surgeons to choose either hemiarthroplasty or internal fixation for 2 different female patients with a displaced femoral neck fracture. Setting The Canadian Orthopaedic Association Meeting, Halifax, May 1995. Patients The scenario in the first patient was of an independent 70-year-old woman with no pre-existing medical conditions. The scenario in the second patient was of a housebound 84-year-old woman with co-morbidity. Main outcome measures Proportion of surgeons choosing either hemiarthroplasty or internal fixation for each case scenario. Distribution of reasons to explain the treatment decision. Results Ninety-nine surgeons responded. For the case of the 70-year-old woman, 47% chose hemiarthroplasty and 53% chose internal fixation (p = 0.60), and for the 84-year-old woman, 96% chose hemiarthroplasty. These findings were consistent within the subgroups of teaching surgeons and community practice surgeons. Surgeons with 10 years or less of practice tended to favour hemiarthroplasty whereas those with more than 15 years’ practice favoured internal fixation. Important reasons for treatment choice were avoidance of reoperation in the hemiarthroplasty group (85%) and better hip function in the fixation group (83%), durability (83%) and ease of revision (77%). Conclusion The surgeon’s interpretation of the importance of reoperation and function underlies the differences in treatment decision regarding the management of femoral neck fractures in elderly patients. PMID:9267295
Numerical-experimental study of internal fixation system "Dufoo" for vertebral fractures.
Nieto-Miranda, J Jesús; Faraón-Carbajal Romero, Manuel; Sánchez-Aguilar, Jons
2012-01-01
We describe a numerical experimental study of the stress generated by the internal fixation system "Dufoo" used in the treatment of vertebral fractures with the purpose of validating the numerical model of human lumbar vertebrae under the main physiological loads that the human body is exposed to in this area. The objective is to model and numerically simulate the elements of the musculoskeletal system to collect the stresses generated and other parameters that are difficult to measure experimentally in the thoracic lumbar vertebrae. We used an internal fixator "Dufoo" and vertebrae L2-L3-L4 specimens from pig and human. The system uses a total L3 corpectomy. The fixator acts as a mechanical bridge implant from L2 to L4. Numerical analysis was performed using the finite element method (FEM). For the experimental study, reflective photoelasticity and extensometry were used. Torsion and combined loads generate the main displacements and stresses in the study system, determining that the internal fixation carries out part of the function of the damaged organ structure when absorbing the stresses presented by applied loads. Numerical analysis allows great freedom in the management of the variables involved in the developed models using radiological images. Geometric models are obtained and are entered into FEM programs that allow testing using parameters that, under actual conditions, may not be easily carried out, allowing to comprehensively determine the biomechanical behavior of the coupled system of study.
Zrounba, Hugues; Lutz, Jean-Christophe; Zink, Simone; Wilk, Astrid
2014-09-01
Surgical management of mandibular condyle fractures is still controversial. Although it provides better outcome than closed treatment questions still remain about the surgical approach and the osteosynthesis devices to be used. Between 2005 and 2010, we managed 168 mandibular condyle fractures with open treatment. Two surgical approaches were used in this study, a pre-auricular and a high submandibular approach (one or the other or as a combined approach). Internal fixation was performed using TCP(®) plates (Medartis, Basel, Switzerland) or with two lag screws (15 and 17 mm). Delta plates were used in 15 cases (8.9%). We report the epidemiology of these fractures and the outcomes of the surgical treatment. We assessed the complications related to the surgical procedure and those related to the osteosynthesis material. The facial nerve related complication rate was very low and the osteosynthesis materials used proved to be strong enough to realize a stable fixation. The two approaches used in this study appeared to be safe with good aesthetic results. Most of the surgical procedure failures occurred in high subcondylar fractures especially when bilateral. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Significance of Phosphoenolpyruvate Carboxylase during Ammonium Assimilation
Guy, Robert D.; Vanlerberghe, Greg C.; Turpin, David H.
1989-01-01
The effect of N-assimilation on the partitioning of carbon fixation between phosphoenolpyruvate carboxylase (PEPcase) and ribulose bisphosphate carboxylase/oxygenase (Rubisco) was determined by measuring stable carbon isotope discrimination during photosynthesis by an N-limited green alga, Selenastrum minutum (Naeg.) Collins. This was facilitated by a two process model accounting for simultaneous CO2 fixation and respiratory CO2 release. Discrimination by control cells was consistent with the majority of carbon being fixed by Rubisco. During nitrogen assimilation however, discrimination was greatly reduced indicating an enhanced flux through PEPcase which accounted for upward of 70% of total carbon fixation. This shift toward anaplerotic metabolism supports a large increase in tricarboxylic acid cycle activity primarily between oxaloacetate and α-ketoglutarate thereby facilitating the provision of carbon skeletons for amino acid synthesis. This provides an example of a unique set of conditions under which anaplerotic carbon fixation by PEPcase exceeds photosynthetic carbon fixation by Rubisco in a C3 organism. Images Figure 6 PMID:16666678
Guy, R D; Vanlerberghe, G C; Turpin, D H
1989-04-01
The effect of N-assimilation on the partitioning of carbon fixation between phosphoenolpyruvate carboxylase (PEPcase) and ribulose bisphosphate carboxylase/oxygenase (Rubisco) was determined by measuring stable carbon isotope discrimination during photosynthesis by an N-limited green alga, Selenastrum minutum (Naeg.) Collins. This was facilitated by a two process model accounting for simultaneous CO(2) fixation and respiratory CO(2) release. Discrimination by control cells was consistent with the majority of carbon being fixed by Rubisco. During nitrogen assimilation however, discrimination was greatly reduced indicating an enhanced flux through PEPcase which accounted for upward of 70% of total carbon fixation. This shift toward anaplerotic metabolism supports a large increase in tricarboxylic acid cycle activity primarily between oxaloacetate and alpha-ketoglutarate thereby facilitating the provision of carbon skeletons for amino acid synthesis. This provides an example of a unique set of conditions under which anaplerotic carbon fixation by PEPcase exceeds photosynthetic carbon fixation by Rubisco in a C(3) organism.
In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.
Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko
2013-03-01
Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.
Evaluation of Bite Force After Open Reduction and Internal Fixation Using Microplates
Kumar, S Tharani; Saraf, Saurabh; Devi, S Prasanna
2013-01-01
The primary aim of this study is to determine maximum bite force in molar and incisor regions of healthy individuals, to evaluate the bite force after open reduction and internal fixation of mandibular fractures using micro plates, for a period of up to 6 weeks and to determine the rate of recovery of maximum bite force in an Indian population. PMID:24910656
Sunness, Janet S.; Applegate, Carol A.; Haselwood, David; Rubin, Gary S.
2009-01-01
Purpose To study fixation patterns and reading rates in eyes with central scotomas from geographic atrophy (GA) of age-related macular degeneration and to compare fixation patterns with those of patients with Stargardt disease. Methods Scanning laser ophthalmoscope analysis of fixation patterns in eyes with 20/80 to 20/200 visual acuity. Included were 41 eyes of 35 patients with GA and 10 eyes of 5 patients with Stargardt disease. The patients with GA also were tested for maximum reading rate, and the size of the areas of atrophy were measured by fundus photograph analysis. Results Sixty-three percent of GA eyes fixating outside the atrophy placed the scotoma to the right of fixation in visual field space, 22% placed the scotoma above fixation, and 15% placed it to the left, regardless of the laterality of the GA eye. Fixation was stable in subsequent years of testing for scotoma placement to the right of or above fixation. All GA eyes fixated immediately adjacent to the atrophy. In contrast, seven of ten eyes with Stargardt disease fixated at a considerable distance from the scotoma border, with the dense scotoma far above the fixation site in visual field space. For the patients with GA, the maximum reading rate was highly correlated with size of the atrophic area, but not with age or visual acuity within the limited visual acuity range tested. There was a trend to more rapid reading with the scotoma above fixation and slower reading with the scotoma to the left. Conclusion There is a preference for fixation with the scotoma to the right in eyes with GA. Patients with Stargardt disease use different strategies for fixation, perhaps due to subclinical pathology adjacent to the atrophic regions. The size of the atrophic area in GA plays the predominant role in reading rate for eyes that have already lost foveal vision. PMID:8841306
Zhang, Shi-min; Zhang, Zhao-jie; Liu, Yu-zhang; Zhang, Lu-tang; Li, Xing
2011-11-01
To discuss the efficacy of lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh in the treatment of severe thoracolumbar burst fracture. From January 2008 to January 2010, 21 patients with severe thoracolumbar burst fracture were treated with lateral anterior decompression, internal fixation with Ventrofix, bone graft with titanic mesh. There were 15 males and 6 females, ranging in age from 21 to 46 years with an average of 32.2 years. Segment of fracture: 3 cases were in T11, 6 cases in T12, 7 cases in L1, 5 cases in L2. The mean kyphosis angle was 20.1 degrees and loading of fracture was 7.8 scores. Twenty-one cases accompany with incomplete paralysis. Nerves functions were observed according to Frankel grade; correction and maintain of kyphosis angle were observed by X-rays and CT. All the patients were followed up from 12 to 34 months with an average of 18.5 years. Postoperative complication including injury of pleura in 1 case, dynamic ileus in 2 cases, ilioinguinal nerve injury in 1 case, faulty union of wound in 1 case. All the above complications got recovery after symptomatic treatment. The mean kyphosis angle in fusional segment were 4.2 degrees and the rate of correction was 79%. Nerves functions of all patients got improvement and no internal fixation fail, kyphosis angle obviously lost, titanium mesh shifting, loosening and breakage of screw were found at final follow-up. Lateral anterior decompression, bone graft with titanic mesh, internal fixation with Ventrofix is an idea technique for severe thoracolumber burst fracture, but the method can not be used for patient with severity osteoporosis.
Routt, M L; Simonian, P T; Defalco, A J; Miller, J; Clarke, T
1996-05-01
Associated urological and orthopedic injuries of the pelvic ring are complex with numerous potential complications. These patients are treated optimally using a team approach. The combined expertise is not only helpful initially when managing these difficult patients, but also later as problems develop. This study describes a treatment protocol and reports the early results of 23 patients with unstable pelvic fractures and associated bladder or urethral disruptions, or both, treated surgically with open reduction and internal fixation of the anterior pelvic ring injuries at the same anesthetic and using the same surgical exposure as the urethral realignments or bladder repairs or both. Early complications occurred in four patients (17%): one patient sustained a fifth lumbar nerve injury caused by the pelvic reduction procedure, and three patients had anterior pelvic internal fixation failures. Late complications occurred in eight patients (35%). There was one deep wound infection (4.3%) that presented 6 weeks after injury. Late urological complications occurred in seven patients (30%). Four of the nine male patients with urethral disruptions had urethral stricture after their primary urethral realignments (44%). Three of the 18 male patients admitted to impotence (16.7%). One of the three had a residual thoracic paraplegia caused by a burst fracture. One of the five female patients had urinary incontinence and required a bladder suspension operation to restore normal function (20%). A low infection rate can be expected despite the use of internal fixation. Early urethral "indirect" realignments avoid more difficult delayed open repairs; however, late urological complication rates are still high. Early "direct" bladder repairs are easily performed at the time of anterior pelvic open reduction and internal fixation. Suprapubic tubes are not necessary to adequately divert the urine when large diameter urethral catheters are used in these patients.
Wang, Gang; Xu, Yiming; Zhang, Lina; Ye, Dongmei; Feng, Xianxuan; Fu, Tengfei; Bai, Yuehong
2015-01-01
Microwaves are used in one method of physical therapy and can increase muscle tissue temperature which is useful for improving muscle, tendon and bone injuries. In the study, we sought to determine whether titanium alloy internal fixations influence apoptosis in tissues subjected to microwave treatments at 2,450 MHz and 40 W during the healing of fractures because this issue is not yet fully understood. In this study, titanium alloy internal fixations were used to treat 3.0-mm transverse osteotomies in the middle of New Zealand rabbits' femurs. After the operation, 30-day microwave treatments were applied to the 3.0 mm transverse osteotomies 3 days after the operation. The changes in the temperatures of the muscle tissues in front of the implants or the 3.0 mm transverse osteotomies were measured during the microwave treatments. To characterize the effects of titanium alloy internal fixations on apoptosis in the muscles after microwave treatment, we performed TUNEL assays, fluorescent real-time (quantitative) PCR, western blotting analyses, reactive oxygen species (ROS) detection and transmission electron microscopy examinations. The temperatures were markedly increased in the animals with the titanium alloy implants. Apoptosis in the muscle cells of the implanted group was significantly more extensive than that in the non-implanted control group at different time points. Transmission electron microscopy examinations of the skeletal muscles of the implanted groups revealed muscular mitochondrial swelling, vacuolization. ROS, Bax and Hsp70 were up-regulated, and Bcl-2 was down-regulated in the implanted group. Our results suggest that titanium alloy internal fixations caused greater muscular tissue cell apoptosis following 2,450 MHz, 40 W microwave treatments in this rabbit femur fracture models.
Zhang, Lina; Ye, Dongmei; Feng, Xianxuan; Fu, Tengfei; Bai, Yuehong
2015-01-01
Objective Microwaves are used in one method of physical therapy and can increase muscle tissue temperature which is useful for improving muscle, tendon and bone injuries. In the study, we sought to determine whether titanium alloy internal fixations influence apoptosis in tissues subjected to microwave treatments at 2,450 MHz and 40 W during the healing of fractures because this issue is not yet fully understood. Methods In this study, titanium alloy internal fixations were used to treat 3.0-mm transverse osteotomies in the middle of New Zealand rabbits’ femurs. After the operation, 30-day microwave treatments were applied to the 3.0 mm transverse osteotomies 3 days after the operation. The changes in the temperatures of the muscle tissues in front of the implants or the 3.0 mm transverse osteotomies were measured during the microwave treatments. To characterize the effects of titanium alloy internal fixations on apoptosis in the muscles after microwave treatment, we performed TUNEL assays, fluorescent real-time (quantitative) PCR, western blotting analyses, reactive oxygen species (ROS) detection and transmission electron microscopy examinations. Results The temperatures were markedly increased in the animals with the titanium alloy implants. Apoptosis in the muscle cells of the implanted group was significantly more extensive than that in the non-implanted control group at different time points. Transmission electron microscopy examinations of the skeletal muscles of the implanted groups revealed muscular mitochondrial swelling, vacuolization. ROS, Bax and Hsp70 were up-regulated, and Bcl-2 was down-regulated in the implanted group. Conclusion Our results suggest that titanium alloy internal fixations caused greater muscular tissue cell apoptosis following 2,450 MHz, 40 W microwave treatments in this rabbit femur fracture models. PMID:26132082
PECTUS CARINATUM: A NOVEL METHOD OF STERNAL FIXATION.
Taha, Assad; Sfeir, Pierre; Al-Taki, Muhyeddine
2016-01-01
The traditional method for fixing the sternum during surgical repair of pectus carinatum is through the use of a stainless steel bar (Adkin’s strut). In this article we describe a new method of sternal fixation using nonabsorbable sutures which are placed in a transverse and crossed fashion anterior to the sternum. This method provides stable sternal fixation and spares the patient a second operation to remove the steel bar. The absence of metallic implants allows clearer view of the thoracic structures in future X-rays, CT scans and MRI, and is likely to be more acceptable to patients than the implantation of a metallic strut in their chest. In addition, it is less costly.
Bednarz, Vanessa N; Naumann, Malik S; Cardini, Ulisse; van Hoytema, Nanne; Rix, Laura; Al-Rshaidat, Mamoon M D; Wild, Christian
2018-01-01
Tropical corals are often associated with dinitrogen (N2)-fixing bacteria (diazotrophs), and seasonal changes in key environmental parameters, such as dissolved inorganic nitrogen (DIN) availability and seawater temperature, are known to affect N2 fixation in coral-microbial holobionts. Despite, then, such potential for seasonal and depth-related changes in N2 fixation in reef corals, such variation has not yet been investigated. Therefore, this study quantified seasonal (winter vs. summer) N2 fixation rates associated with the reef-building coral Stylophora pistillata collected from depths of 5, 10 and 20 m in the northern Gulf of Aqaba (Red Sea). Findings revealed that corals from all depths exhibited the highest N2 fixation rates during the oligotrophic summer season, when up to 11% of their photo-metabolic nitrogen demand (CPND) could be met by N2 fixation. While N2 fixation remained seasonally stable for deep corals (20 m), it significantly decreased for the shallow corals (5 and 10 m) during the DIN-enriched winter season, accounting for less than 2% of the corals' CPND. This contrasting seasonal response in N2 fixation across corals of different depths could be driven by 1) release rates of coral-derived organic matter, 2) the community composition of the associated diazotrophs, and/or 3) nutrient acquisition by the Symbiodinium community.
NASA Astrophysics Data System (ADS)
Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng
2017-07-01
The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.
Carlsson, Ake; Björkman, Anders; Besjakov, Jack; Onsten, Ingemar
2005-06-01
The question whether the tibial component of a total knee arthroplasty should be fixed to bone with or without bone cement has not yet been definitely answered. We studied movements between the tibial component and bone by radiostereometry (RSA) in total knee replacement (TKR) for 3 different types of fixation: cemented fixation (C-F), uncemented porous fixation (UC-F) and uncemented porous hydroxyapatite fixation (UCHA-F). 116 patients with osteoarthrosis, who had 146 TKRs, were included in 2 randomized series. The first series included 86 unilateral TKRs stratified into 1 of the 3 types of fixation. The second series included 30 patients who had simultaneous bilateral TKR surgery, and who were stratified into 3 subgroups of pairwise comparisons of the 3 types of fixation. After 5 years 2 knees had been revised, neither of which were due to loosening. 1 UCHA-F knee in the unilateral series showed a large and continuous migration and a poor clinical result, and is a pending failure. The C-F knees rotated and migrated less than UC-F and UCHA-F knees over 5 years. UCHA-F migrated less than UC-F after 1 year. Cementing of the tibial component offers more stable bone-implant contact for 5 years compared to uncemented fixation. When using uncemented components, however, there is evidence that augmenting a porous surface with hydroxyapatite may mean less motion between implant and bone after the initial postoperative year.
Long, Xi-En; Yao, Huaiying; Wang, Juan; Huang, Ying; Singh, Brajesh K; Zhu, Yong-Guan
2015-06-16
Previous studies suggested that microbial photosynthesis plays a potential role in paddy fields, but little is known about chemoautotrophic carbon fixers in drained paddy soils. We conducted a microcosm study using soil samples from five paddy fields to determine the environmental factors and quantify key functional microbial taxa involved in chemoautotrophic carbon fixation. We used stable isotope probing in combination with phospholipid fatty acid (PLFA) and molecular approaches. The amount of microbial (13)CO2 fixation was determined by quantification of (13)C-enriched fatty acid methyl esters and ranged from 21.28 to 72.48 ng of (13)C (g of dry soil)(-1), and the corresponding ratio (labeled PLFA-C:total PLFA-C) ranged from 0.06 to 0.49%. The amount of incorporationof (13)CO2 into PLFAs significantly increased with soil pH except at pH 7.8. PLFA and high-throughput sequencing results indicated a dominant role of Gram-negative bacteria or proteobacteria in (13)CO2 fixation. Correlation analysis indicated a significant association between microbial community structure and carbon fixation. We provide direct evidence of chemoautotrophic C fixation in soils with statistical evidence of microbial community structure regulation of inorganic carbon fixation in the paddy soil ecosystem.
Marie, Cronskär
2015-08-01
In the cases, when clavicle fractures are treated with a fixation plate, opinions are divided about the best position of the plate, type of plate and type of screw units. Results from biomechanical studies of clavicle fixation devices are contradictory, probably partly because of simplified and varying load cases used in different studies. The anatomy of the shoulder region is complex, which makes it difficult and expensive to perform realistic experimental tests; hence, reliable simulation is an important complement to experimental tests. In this study, a method for finite element simulations of stresses in the clavicle plate and bone is used, in which muscle and ligament force data are imported from a multibody musculoskeletal model. The stress distribution in two different commercial plates, superior and anterior plating position and fixation including using a lag screw in the fracture gap or not, was compared. Looking at the clavicle fixation from a mechanical point of view, the results indicate that it is a major benefit to use a lag screw to fixate the fracture. The anterior plating position resulted in lower stresses in the plate, and the anatomically shaped plate is more stress resistant and stable than a regular reconstruction plate.
Fixation of mandibular fractures with biodegradable plates and screws.
Yerit, Kaan C; Enislidis, Georg; Schopper, Christian; Turhani, Dritan; Wanschitz, Felix; Wagner, Arne; Watzinger, Franz; Ewers, Rolf
2002-09-01
Little data exist regarding the use of biodegradable plates and screws for the internal fixation of human mandibular fractures. The purpose of this study was to evaluate the stability of biodegradable, self-reinforced poly-L-lactide plates and screws for the internal fixation of fractures of the human mandible. Twenty-two individuals (14 male, 8 female; average age, 26.3 years) with a variety of fracture patterns of the mandible underwent management with a biodegradable fixation system. After surgery, maxillomandibular fixation was applied in 3 cases. Images (panoramic radiograph, computed tomographic scan) were taken immediately after surgery and at the 4-week, 8-week, 12-week, and 24-week intervals. The follow-up period averaged 49.1 weeks (range, 22 to 78 weeks). Mucosal dehiscences over the resorbable devices were present in 2 patients. In 1 of these 2 cases, the material had to be replaced with titanium plates. Mucosal healing and consolidation of the fracture were normal in all other patients. Self-reinforced biodegradable osteosynthesis materials provide a reliable and sufficient alternative to conventional titanium plate systems.
Sun, Yufu; Sun, Kai; Jiang, Wenxue
2018-06-01
To conduct a meta-analysis with randomized controlled trials (RCTs) published in full text to demonstrate database to show the associations of perioperative, postoperative outcomes of arthroscopic reduction and percutaneous fixation(ARPF) and open reduction and internal fixation(ORIF) for tibial plateau fractures to provide the predictive diagnosis for clinic. Literature search was performed in PubMed, Embase, Web of Science and Cochrane Library for information from the earliest date of data collection to June 2017. RCTs comparing the benefits and risks of ARPF with those of ORIF in tibial plateau fractures were included. Statistical heterogeneity was quantitatively evaluated by X 2 test with the significance set P < 0.10 or I 2 > 50%. Seven RCTs consisting of 571 patients were included.(288 ARPF patients; 283 ORIF patients;). Pooled results showed that ORIF was related to a greater increase in operative time, incision length, hospital stay, perioperative complications, and full weight bearing compared with ARPF. The results showed that ARPF was related to a greater increase in ROM Rasmussen Scores compared with ORIF (WMD = 10.38; 95% CI, 8.31, 12.45; P < 0.10). This meta-analysis showed that arthroscopic reduction and percutaneous fixation for tibial plateau fractures, compared with open reduction and internal fixation, could demonstrate an decreased risk of perioperative and postoperative complications and improve clinical outcome in operative time, incision length, hospital stay, perioperative complications, full weight bearing and Rasmussen Scores. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fractures of the growing mandible.
Kushner, George M; Tiwana, Paul S
2009-03-01
Oral and maxillofacial surgeons must constantly weigh the risks of surgical intervention for pediatric mandible fractures against the wonderful healing capacity of children. The majority of pediatric mandibular fractures can be managed with closed techniques using short periods of maxillomandibular fixation or training elastics alone. Generally, the use of plate- and screw-type internal fixation is reserved for difficult fractures. This article details general and special considerations for this surgery including: craniofacial growth & development, surgical anatomy, epidemiology evaluation, various fractures, the role rigid internal fixation and the Risdon cable in pediatric maxillofacial trauma. It concludes with suggestions concerning long-term follow-up care in light of the mobility, insurance obstacles, and family dynamics facing the patient population.
Gunst, S; Del Chicca, F; Fürst, A E; Kuemmerle, J M
2016-09-01
There are no reports on the configuration of equine central tarsal bone fractures based on cross-sectional imaging and clinical and radiographic long-term outcome after internal fixation. To report clinical, radiographic and computed tomographic findings of equine central tarsal bone fractures and to evaluate the long-term outcome of internal fixation. Retrospective case series. All horses diagnosed with a central tarsal bone fracture at our institution in 2009-2013 were included. Computed tomography and internal fixation using lag screw technique was performed in all patients. Medical records and diagnostic images were reviewed retrospectively. A clinical and radiographic follow-up examination was performed at least 1 year post operatively. A central tarsal bone fracture was diagnosed in 6 horses. Five were Warmbloods used for showjumping and one was a Quarter Horse used for reining. All horses had sagittal slab fractures that began dorsally, ran in a plantar or plantaromedial direction and exited the plantar cortex at the plantar or plantaromedial indentation of the central tarsal bone. Marked sclerosis of the central tarsal bone was diagnosed in all patients. At long-term follow-up, 5/6 horses were sound and used as intended although mild osteophyte formation at the distal intertarsal joint was commonly observed. Central tarsal bone fractures in nonracehorses had a distinct configuration but radiographically subtle additional fracture lines can occur. A chronic stress related aetiology seems likely. Internal fixation of these fractures based on an accurate diagnosis of the individual fracture configuration resulted in a very good prognosis. © 2015 EVJ Ltd.
Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.
Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P
1998-02-01
A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.
Central Field Index Versus Visual Field Index for Central Visual Function in Stable Glaucoma.
Rao, Aparna; Padhy, Debananda; Mudunuri, Harika; Roy, Avik K; Sarangi, Sarada P; Das, Gopinath
2017-01-01
To compare the variability of central field index (CFI) versus visual field index (VFI) in stable glaucoma with central fixation involvement. For this retrospective study, we identified multiple visual fields (VFs) of patients with repeatable central fixation involvement on Humphrey VFs (24-2 and 10-2 program) which were stable (clinically and on VFs) over a very short period of 2 to 3 months. The VFI and CFI were calculated as described in earlier reports. We graded the fields as early [mean deviation (MD)>-6 dB], moderate (-6.1 to -12 dB), and severe glaucoma (<-12 dB) based on MD on 24-2 program. The variability of CFI and VFI between visits and across different severity of glaucoma was compared. Relation of the divergence to field indices and clinical parameters were assessed. The intervisit difference for VFI was greater than CFI ranging from -4% to 9% versus -1% to 8% in early (P=0.9), -13% to 18% versus -6% to 17% (P=0.056) in moderate, and -21% to 19% versus -9% to 9% (P<0.001) in severe glaucoma. The CFI within each group had narrower range than VFI with maximum range in severe glaucoma (33% to 95%). The divergence of CFI from VFI started at MD 24-2 beyond (worse) -10 dB. This difference between CFI and VFI was associated significantly with number of points with P<1% on 24-2 (R=80.3%). CFI is less variable than VFI in stable eyes with fixation involvement especially in severe glaucoma indicating need for incorporating CFI calculation for monitoring advanced disease in eyes with central defects.
Management of comminuted but continuous mandible defects after gunshot injuries.
Rana, Majeed; Warraich, Riaz; Rashad, Ashkan; von See, Constantin; Channar, Kashif A; Rana, Madiha; Stoetzer, Marcus; Gellrich, Nils-Claudius
2014-01-01
Firearm injuries continue as a major public health problem, contributing significant morbidity, mortality, and expense to our society. There are four main steps in the management of patients with gunshot wounds to the face: securing an airway, controlling haemorrhage, identifying other injuries and definitive repair of the traumatic facial deformities. The objective of this study was to determine late outcome of two treatment options by open reduction and internal fixation versus closed reduction and maxillomandibular fixation (MMF) in the treatment of gunshot injuries of the mandible. Sixty patients of gunshot injury were randomly allocated in two groups. In group A, 30 patients were treated by open reduction and internal fixation and in group B, 30 patients were treated by closed reduction and maxillomandibular fixation. Patients were discharged as the treatment completed and recalled for follow up. Up to 3 months after injury, fortnightly complications like infection, malocclusion, malunion of fractured fragments, facial asymmetry, sequestration of bone and exposed plates were evaluated and the differences between two groups were assessed. The follow-up period ranged from 3 months to 10 months. Patients treated by open reduction tended to have less complications as compared to closed reduction. Based on this study open reduction and internal fixation is the best available method for the treatment of gunshot mandible fractures without continuity defect. Copyright © 2012 Elsevier Ltd. All rights reserved.
Wang, Cheng; Li, Ying; Huang, Lei; Wang, Manyi
2010-10-01
To compare the results of two-staged open reduction and internal fixation (ORIF) and limited internal fixation with external fixator (LIFEF) for closed tibial plafond fractures. From January 2005 to June 2007, 56 patients with closed type B3 or C Pilon fractures were randomly allocated into groups I and II. Two-staged ORIF was performed in group I and LIFEF in group II. The outcome measures included bone union, nonunion, malunion, pin-tract infection, wound infection, osteomyelitis, ankle joint function, etc. These postoperative data were analyzed with Statistical Package for Social Sciences (SPSS) 13.0. Incidence of superficial soft tissue infection (involved in wound infection or pin-tract infection) in group I was lower than that in group II (P < 0.05), with significant difference. Group I has significantly less radiation exposure (P < 0.001). Group II had higher rates of malunion, delayed union, and arthritis symptoms, with no statistical significance. Both groups resulted similar ankle joint function. Logistic regression analysis indicated that smoking and fracture pattern were the two factors significantly influencing the final outcomes. In the treatment of closed tibial plafond fractures, both two-staged ORIF and LIFEF offer similar results. Patients undergo LIFEF carry significantly greater radiation exposure and higher superficial soft tissue infection rate (usually occurs on pin tract and does not affect the final outcomes).
Xie, Si-Tian; Singhal, Dhruv; Chen, Chien-Tzung; Chen, Yu-Ray
2013-12-01
Although the appropriate management of condylar process fractures after miniplate or microplate fixation has been described, there has been no comparative analysis of these plating systems. A retrospective review of patients who underwent open reduction and internal fixation (ORIF) of condylar head or neck fractures at our institution from January 2000 through August 2010 identified 70 patients. Of these, 38 were treated with microplates and 32 with miniplates. The primary functional and radiographic results were the maximal mouth opening and condylar bone resorption, respectively. The rates of complications, including malocclusion, chin deviation, temporomandibular joint complaints, and facial nerve palsy, were recorded. The maximal mouth opening was larger in the microplate group than in the miniplate group throughout the follow-up period; this difference was statistically significant 12 (P = 0.020), 18 (P = 0.026), and 24 (P = 0.032) months after ORIF. Similarly, the radiographic scores for bone resorption and condyle morphology were significantly better in the microplate group than in the miniplate group throughout the follow-up period [6 (P = 0.011), 12 (P = 0.035), 24 (P = 0.026), and 48 (P = 0.040) months after ORIF]. Moreover, patients who underwent miniplate fixation experienced a significantly higher incidence of temporomandibular joint click than those who underwent microplate fixation (P = 0.014). Microplates limit dissection, providing excellent fixation for intracapsular condylar head fractures, and also provide adequate rigidity for fixation of condylar neck fractures. Microplate fixation of condylar head and neck fractures yielded excellent functional and radiographic results. The rates of complications after microplate fixation were equal to or less than those in the miniplate group. Prospective studies are needed to confirm these findings.
Jani, Mihir M; Ricci, William M; Borrelli, Joseph; Barrett, Susan E; Johnson, Jeffrey E
2003-11-01
Surgical treatment of ankle fractures in patients with diabetes mellitus is associated with a high complication rate. Diabetic patients with peripheral neuropathy are a particularly difficult group to treat because of their inability to sense deep infection, repeat trauma, and wound complications. The purpose of this study was to evaluate a protocol that included transarticular fixation and prolonged, protected weightbearing in the treatment of unstable ankle fractures in diabetic patients with peripheral neuropathy and loss of protective sensibility. The authors retrospectively reviewed the records of 15 patients with diabetes mellitus, unstable ankle fractures (AO classification 44B), and loss of protective sensibility confirmed via testing with a 5.07 Semmes-Weinstein monofilament. Retrograde transcalcaneal-talar-tibial fixation using large Steinmann pins or screws in conjunction with standard techniques of open reduction and internal fixation was used. The postoperative treatment protocol included: 1) short leg, total contact casting and nonweightbearing status for 12 weeks; 2) removal of the intramedullary implants between 12 and 16 weeks; 3) application of a walker boot or short leg cast with partial weightbearing for an additional 12 weeks; and 4) transition to a custom-molded ankle-foot orthosis (AFO) or custom total-contact inserts in appropriate diabetic footwear. The major complication rate for all fractures was 25% (4/16) and for closed fractures was 23% (3/13). These are lower than previously reported rates between 30% (3/10) and 43% (9/21) for diabetic patients with and without neuropathy. The amputation rate for all fractures was 13% (2/16) and for closed fractures alone was 8% (1/13). These are similar to previously reported rates of 10% (2/10) to 20% (2/21). There were no deaths or Charcot malunions in this series. The combination of transarticular fixation and prolonged, protected weightbearing provided 13 of 15 patients with a stable ankle for weightbearing. Although these fractures remain a treatment challenge, this study presents a successful, multidisciplinary protocol for treatment of unstable ankle fractures in the most challenging group of diabetic patients - those with loss of protective sensibility.
Molecular Ecological and Stable Isotopic Studies of Nitrogen Fixation in Modern Microbial Mats
NASA Technical Reports Server (NTRS)
Bebout, B. M.; Crumbliss, L. L.; DesMarais, D. J.; Hogan, M. E.; Omoregie, E.; Turk, K. A.; Zehr, J. P.
2003-01-01
Nitrogen is usually the element limiting biological productivity in the marine environment. Microbial mats, laminated microbial communities analogous to some of the oldest forms of life on Earth, are often the sites of high rates of N fixation (the energetically expensive conversion of atmospheric dinitrogen into a biologically useful form). The N fixing enzyme nitrogenase is generally considered to be of ancient origin, and is widely distributed throughout the Bacterial and Archaeal domains of life, indicating an important role for this process over evolutionary time. The stable isotopic signature of N fixation is purportedly recognizable in organic matter (ancient kerogens as well as present-day microbial mats) as a delta (15)N(sub organic) near zero. We studied two microbial mats exhibiting different rates of N fixation in order to better understand the impact of N fixation on the delta (15)N (sub organic) of the mats, as well as what organisms are important in this process. Mats dominated by the cyanobacterium Microcoleus chthonoplastes grow in permanently submerged hypersaline salterns, and exhibit low rates of N fixation, whereas mats dominated by the cyanobacterium Lyngbya spp grow in an intertidal area, and exhibit rates of N fixation an order of magnitude higher. To examine successional stages in mat growth, both developing and established mats at each location were sampled. PCR and RT-PCR based approaches were used to identify, respectively, the organisms containing nifH (one of the genes that encode nitrogenase) as well as those expressing nifH in these mats. Both mats exhibited a distinct diel cycle of N fixation, with highest rates occurring at night. The delta (15)N(sub organic) of the subtidal Microcoleus mats is near zero whereas the delta (15)N(sub organic) is slightly more positive (+ 2-3%), in the intertidal Lyngbya mats, an interesting difference in view of the fact that overall rates of activity in the intertidal mats are much higher that those in the submerged hypersaline mats. Developing mats in both the subtidal and intertidal locations had delta (15)N(sub organic) values very near those of the established mats. Further work is necessary in order to determine the importance of other transformations of nitrogen on the delta (15)N(sub organic) signature of the mats.
Rhee, John M; Register, Bradley; Hamasaki, Takahiko; Franklin, Betty
2011-01-01
Prospective clinical series. To evaluate the ability of plate-only laminoplasty to achieve stable laminar arch reconstruction and to determine the rate and time course with which bony healing occurs in such constructs. Reconstruction of a stable laminar arch with sufficient room for the decompressed spinal cord is a desired goal when performing cervical laminoplasty for myelopathy. Traditional forms of laminoplasty fixation, such as sutures, bone struts, and ceramic spacers, may be associated with complications including loss of fixation, dislodgement with neurologic compromise, and premature laminoplasty closure. Plates, in contrast, provide more rigid fixation. Plate-only laminoplasty is gaining popularity as a method of laminoplasty fixation, but there is little data on its effectiveness. Fifty-four patients who underwent open door laminoplasty for cervical myelopathy and had available postoperative computed tomography (CT) scans formed the basis of this study. In all cases, a 4-mm round burr was used to create the hinge at the junction of the lateral mass and lamina by completely removing the dorsal cortex and thinning the ventral cortex until a greenstick deformation of the hinge could be produced. Laminoplasty plates were used as the sole method of fixation. No supplemental bone graft struts were used on the plated side, and the hinge side was not bone grafted. Axial CT scans obtained at 3, 6, and 12 months postoperatively were assessed for plate complications and bony healing of the hinge. No plate failures, dislodgements, or premature closures occurred in any of the levels at any time postoperatively. Computed tomography scan review demonstrated that 55% of levels were healed at 3 months, 77% at 6 months, and 93% at 12 months. At each timepoint, C6 and C7 had the highest hinge healing rates. Laminar screw backout was seen in 5/217 (2.3%) of levels, but was not associated with plate dislodgement, laminoplasty closure, or neurologic consequences, and did not occur in any case in which 2 laminar screws had been placed. Plate-only laminoplasty provided stable reconstruction of an expanded laminar arch with no failures, dislodgements, adverse neurologic consequences, or premature closures in 217 levels. Ninety-three percent of hinges demonstrated radiographic union at 12 months, and even those that did not heal by CT scan criteria maintained patent expansion of the spinal canal without adverse neurologic consequences. Supplemental bone graft does not appear necessary when plated laminoplasty is performed.
2012-01-01
The present study is a report of retrospective case series of stress fracture of the olecranon. Six patients presented posterior elbow pain in throwing in baseball and softball, but fracture was not diagnosed in radiographs. We detected stress fracture of the olecranon using computed tomographic (CT) scan and treated the patient with internal fixation with a headless cannulated double threaded screw through a small skin incision. All patients returned to competitive level without elbow complaints after the operation. When throwing athletes present with unusual posterior elbow pain and no significant findings on radiographs, a CT scan examination should be performed. We recommend surgical treatment of internal fixation with a screw through a small skin incision, as a good option for stress fracture of the olecranon in order to allow early return to sports activity in competitive athletes. PMID:23241173
Luo, Xiaohui; Wang, Hang; Fan, Yubo
2007-04-01
This study was aimed to develop a 3-D finite element (3-D FE) model of the mental fractured mandible and design the boundary constrains. The CT images from a health volunteer were used as the original information and put into ANSYS program to build a 3-D FE model. The model of the miniplate and screw which were used for the internal fixation was established by Pro/E. The boundary constrains of different muscle loadings were used to simulate the 3 functional conditions of the mandible. A 3-D FE model of mental fractured mandible under the miniplate-screw internal fixation system was constructed. And by the boundary constraints, the 3 biting conditions were simulated and the model could serve as a foundation on which to analyze the biomechanical behavior of the fractured mandible.
Retinal micropseudocysts in diabetic retinopathy: prospective functional and anatomic evaluation.
Forte, Raimondo; Cennamo, Gilda; Finelli, Maria Luisa; Bonavolontà, Paola; Greco, Giovanni Maria; de Crecchio, Giuseppe
2012-01-01
To evaluate the prevalence, progression and functional predictive value of retinal micropseudocysts (MPCs) in diabetic patients. Prospective controlled observational study. From among all the type 2 diabetic patients evaluated during a period of 5 months between September 2009 and January 2010, we enrolled all patients with retinal MPCs at spectral-domain scanning laser ophthalmoscope/optical coherence tomography (SD-SLO/OCT) not previously treated for diabetic retinopathy. Forty diabetic patients without MPCs served as the control group. Best-corrected visual acuity (BCVA), central retinal thickness (CRT), macular sensitivity and stability of fixation at SD-SLO/OCT microperimetry were measured monthly for 12 months. 22/156 patients with type 2 diabetes (14.1%, 32 eyes) met the inclusion criteria. The 95% confidence interval for the prevalence estimate of MPCs was 12.3-16.6%. Mean BCVA, CRT and central retinal sensitivity at baseline were 77.53 ± 2.2 Early Treatment Diabetic Retinopathy Study letters, 242.31 ± 31.0 µm and 15.95 ± 0.61 dB, respectively. Fixation was stable in all cases. Compared to the control group, eyes with MPCs had similar BCVA but greater CRT (p = 0.01) and reduced macular sensitivity (p = 0.001) at baseline and at each follow-up visit. Over time, CRT remained stable in eyes with MPCs, whereas macular sensitivity progressively decreased. MPCs in diabetic retinopathy are associated, temporally or causally, with a progressive reduction of macular sensitivity despite a stable BCVA, CRT and fixation. Copyright © 2011 S. Karger AG, Basel.
Zhang, Hengyan; Li, Qiyi
2018-01-01
Abstract Rationale: Surgical site infection (SSI) following spine surgeries involving internal fixation often require removing the instrument; however, this can cause spinal instability. Previous reports have demonstrated the usefulness of vacuum sealing drainage (VSD) therapy, but the cases require wound opening, aseptic condition to replace the VSD device, and a secondary operation to close the wound. Thus, to improve the VSD treatment and develop a maneuverable procedure, make sense in spine surgery. Patients concerns: A 59-year-old male patient with a T12 vertebral fracture was affected by SSIs after spinal osteotomy with internal fixation. Diagnoses: The patient complained of wound exudation and had a fever 3 weeks after posterior spinal surgery. Initial serum investigations showed elevated white blood cell count and bacterial cultures of wound exudate were positive for Enterococcus faecalis. Therefore, SSI is confirmed. Interventions: The infection was not controlled after 2 debridements, so the patient was treated with VSD treatment. The VSD foam dressings containing a drainage tube were placed into the wound from the exudation site of the wound until they contacted the internal fixation devices. After covering external fixation devices, continuous drainage was performed for 24 h. The VSD device was replaced every 4 to 5 days until the wound effusion stopped. All of the operations were performed at the bedside without complex manipulation or secondary closure under harsh aseptic condition. Outcomes: Wound exudation decreased remarkably and the infection was controlled 2 weeks after the application of VSD treatment. After 5 weeks, inflammatory indicators all decreased to normal levels and the exudate of the wound had stopped. The VSD treatment was then terminated and the drainage site of the wound was sutured. After 7 weeks, complete wound healing was achieved and no infection recurred during the 6-month follow-up. Lessons: VSD could be a reliable treatment for SSIs that require preservation of internal fixation. Complete opening of the wound during the VSD treatment and secondary wound closure surgery were avoided. PMID:29443786
Murawski, Christopher D; Kennedy, John G
2011-06-01
Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P < .01). The mean physical component of the SF-12 score significantly improved, from 25.69 points preoperatively (range, 6-39) to 54.62 at final follow-up (range, 32-62; P < .01). The mean mental component of the SF-12 score also significantly improved, from 28.20 points preoperatively (range, 14-45) to 58.41 at final follow-up (range, 36-67; P < .01). The mean time to fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.
Judging the judges' performance in rhythmic gymnastics.
Flessas, Konstantinos; Mylonas, Dimitris; Panagiotaropoulou, Georgia; Tsopani, Despina; Korda, Alexandrea; Siettos, Constantinos; Di Cagno, Alessandra; Evdokimidis, Ioannis; Smyrnis, Nikolaos
2015-03-01
Rhythmic gymnastics (RG) is an aesthetic event balancing between art and sport that also has a performance rating system (Code of Points) given by the International Gymnastics Federation. It is one of the sports in which competition results greatly depend on the judges' evaluation. In the current study, we explored the judges' performance in a five-gymnast ensemble routine. An expert-novice paradigm (10 international-level, 10 national-level, and 10 novice-level judges) was implemented under a fully simulated procedure of judgment in a five-gymnast ensemble routine of RG using two videos of routines performed by the Greek national team of RG. Simultaneous recordings of two-dimensional eye movements were taken during the judgment procedure to assess the percentage of time spent by each judge viewing the videos and fixation performance of each judge when an error in gymnast performance had occurred. All judge level groups had very modest performance of error recognition on gymnasts' routines, and the best international judges reported approximately 40% of true errors. Novice judges spent significantly more time viewing the videos compared with national and international judges and spent significantly more time fixating detected errors than the other two groups. National judges were the only group that made efficient use of fixation to detect errors. The fact that international-level judges outperformed both other groups, while not relying on visual fixation to detect errors, suggests that these experienced judges probably make use of other cognitive strategies, increasing their overall error detection efficiency, which was, however, still far below optimum.
Dong, Jian-Bin; Wang, Zhi-Yong; Lu, Hao; Tian, Yuan; Wang, Xin-Rui; Zhang, Zhi-Qiang
2015-03-01
To compare the efficacy of internal fixation (including PFNA and PFN) versus hip replacement (including FHR or THA) in the treatment of trochanteric fractures in adults. Reports of studies using randomized controlled trials (RCT) to compare internal fixationg with hip replacement in the management of intertrochanteric fractures were retrieved (up to January 1, 2013) from the Cochrane Library, PUBMED Data, CNKI (China National Knowledge infrastructure), Elsevier, the Chinese Biomedical Database, Wanfang Data, and manually. Methodological quality of the trials was critically assessed, and relevant data were extracted. Statistical software RevMan 5.0 was used for data-analysis. Seven articles were included in the meta-analysis. The results showed that,compared internal fixation with hip replacement,there were statistical significance in the duration of surgery time [WMD = -2.66, 95% CI (-5.25,-0.06), P = 0.05], intra-operative blood loss [WMD = -24.20, 95% CI (-30.38, -18.02), P < 0.000 01], hospital stays time [WMD = -4.72, 95% CI (-5.18, -4.25), P < 0.000 01], bearing load time [WMD = -29.54, 95% CI (-30.77, -28.31), P < 0.000 01], total complications rate [WMD = 0.15, 95% CI (0.11, 0.22), P < 0.000 01], the good rate of Harris scores [WMD = 1.09, 95% CI (0.54,1.32), P < 0.05]. However, there were no statistical significance in the rate of deep venous thrombosis [WMD = 1.09, 95% CI (0.47, 2.55), P > 0.05]. CON- CLUSION: Hip replacement (containing FHR or THA) for the treatment of intertrochanteric fractures is superior to internal fixa- tion in regards to the duration of surgery time, the mean duration of hosipital stays, mean post-operative down time, intra-opera- tive blood loss, the rate of post-operative good Harris scores. But there is not enough evidence to show any difference between hip replacement (containing THA or FHR) and internal fixation in regards to the rate of deep venous thrombosis. However, internal fixation for the treatment of intertrochanteric fractures is superior to hip replacement (containing FHR or THA) in regards to total complications rate.
The lingual splint: an often forgotten method for fixating pediatric mandibular fractures.
Binahmed, Abdulaziz; Sansalone, Claudio; Garbedian, Justin; Sándor, George K B
2007-01-01
Maxillofacial fractures are uncommon in the pediatric population, and their treatment is unique due to the psychological, physiological, developmental and anatomical characteristics of children. We present the case of a boy who was treated in an outpatient dental clinic using a lingual splint for the reduction, stabilization and fixation of a mandibular body fracture. This technique is a reliable, noninvasive procedure that dentists may consider in selected cases by referral to an oral and maxillofacial surgeon. It also limits the discomfort and morbidity that can be associated with maxillomandibular fixation or open reduction and internal fixation in pediatric patients.
Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y
2013-09-01
To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended than that in S1. Experimental study Level III. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Osmers, I; Winter, M; Krieger, S
2011-03-01
Internal fixation of fractures is an integral part of health care. However this is a privilege of the developed world. For humanitarian aid internal fixation has always been considered as too prone to infection given the poor hygienic conditions, too specialized, too costly and the infrastructure of so-called developing countries too weak to perform internal fixation successfully. Due to the globally increasing density of road traffic an alarming increase in victims of road traffic accidents can be observed. The World Health Organization (WHO) estimates that in 2030 road traffic accidents will be responsible for twice as many deaths as caused by HIV/AIDS.Road traffic accidents are considered to be the new global epidemic. Since the victims are generally young, their rehabilitation has not only a humanitarian, but also an economic impact for low-income countries. The organization Doctors Without Borders (Médecins Sans Frontières; MSF) is not only providing surgical care for victims of violence in war and conflict regions, but has expanded its portfolio to include victims of road traffic accidents and started to perform internal fixation under good hygienic circumstances in closed fractures. The following is a report about the work in a hospital for surgical trauma care in Port Harcourt, Nigeria where victims of road traffic accidents are treated besides victims of urban violence.
Treatment Approach for Infection of Healed Fractures After Internal Fixation.
Lawrenz, Joshua M; Frangiamore, Salvatore J; Rane, Ajinkya A; Cantrell, William Alex; Vallier, Heather A
2017-11-01
To review the efficacy of a treatment approach for patients with infection and colonized implants after open reduction and internal fixation of fractures. Retrospective case series. Level one trauma center. Twenty patients were treated for wound infection with colonized implants after open reduction and internal fixation. Surgical debridement, removal of implants, and a short postoperative oral antibiotic course. The course of patients after surgical debridement and removal of implants, including culture results, antibiotic administration, and presence of recurrent clinical infection and radiographic union. Twenty patients had clinical presentations, including skin breakdown, serous drainage, purulent drainage and/or exposed implants, most commonly of the tibia (15 of 20). Mean time from index procedure to debridement with implant removal was 19.7 months. At the time of debridement and implant removal, 18 of 20 (90%) patients had a positive intraoperative culture (16 routine cultures and 2 broth cultures). The most common bacteria were Enterobacter cloacae (5/17) and methicillin-sensitive Staphylococcus aureus (4/17). All patients had soft tissue healing without signs of recurrent infection after mean follow up of 40 months after implant removal. Surgical debridement with implant removal plus a short oral antibiotic course is effective to resolve wound infection with a colonized implant in the setting of healed fracture after internal fixation. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Li, Jia; Sun, Jin-Ke; Wang, Chen-Lin
2017-06-25
To investigate surgical skills and clinical effects of manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures. From May 2013 to October 2016, 35 patients with grade IV supination-external rotation ankle fractures were treated with percutaneous Kirschner wire internal fixation, involving 22 males and 13 females with an average age of 38.2 years ranged from 18 to 65 years old. The time from injury to operation ranged from 2 h to 10 d with an average of 5 d. Reduction quality was assessed by Burwell-Charnley radiological criteria. Baird-Jackson ankle scoring system was used to assess clinical effects. Thirty-three patients were followed up from 10 to 28 months with an average of 14 months. Fracture healing time ranged from 10 to 18 weeks with an average of 12 weeks. According to Burwell-Charnley radiological criteria, 30 cases were obtained anatomic reduction, 3 cases moderate. According to Baird-Jackson ankle scoring system, total score was 93.8±5.4, 17 cases got excellent result, 12 good, 2 fair and 2 poor. Manipulative reduction and percutaneous Kirschner wire internal fixation in treating grade IV supination-external rotation ankle fractures has advantages of reliable efficacy, less complications. But higher require techniques were required for closed reduction. It is not suitable for severe crushed fracture and compressive articular surface fracture.
Carbon sequestration in soybean crop soils: the role of hydrogen-coupled CO2 fixation
NASA Astrophysics Data System (ADS)
Graham, A.; Layzell, D. B.; Scott, N. A.; Cen, Y.; Kyser, T. K.
2011-12-01
Conversion of native vegetation to agricultural land in order to support the world's growing population is a key factor contributing to global climate change. However, the extent to which agricultural activities contribute to greenhouse gas emissions compared to carbon storage is difficult to ascertain, especially for legume crops, such as soybeans. Soybean establishment often leads to an increase in N2O emissions because N-fixation leads to increased soil available N during decomposition of the low C:N legume biomass. However, soybean establishment may also reduce net greenhouse gas emissions by increasing soil fertility, plant growth, and soil carbon storage. The mechanism behind increased carbon storage, however, remains unclear. One explanation points to hydrogen coupled CO2 fixation; the process by which nitrogen fixation releases H2 into the soil system, thereby promoting chemoautotrophic carbon fixation by soil microbes. We used 13CO2 as a tracer to track the amount and fate of carbon fixed by hydrogen coupled CO2 fixation during one-year field and laboratory incubations. The objectives of the research are to 1) quantify rates of 13CO2 fixation in soil collected from a field used for long-term soybean production 2) examine the impact of H2 gas concentration on rates of 13CO2 fixation, and 3) measure changes in δ13C signature over time in 3 soil fractions: microbial biomass, light fraction, and acid stable fraction. If this newly-fixed carbon is incorporated into the acid-stable soil C fraction, it has a good chance of contributing to long-term soil C sequestration under soybean production. Soil was collected in the field both adjacent to root nodules (nodule soil) and >3cm away (root soil) and labelled with 13CO2 (1% v/v) in the presence and absence of H2 gas. After a two week labelling period, δ13C signatures already revealed differences in the four treatments of bulk soil: -17.1 for root, -17.6 for nodule, -14.2 for root + H2, and -6.1 for nodule + H2. Labelled soil was then placed in nylon mesh bags and buried in the field at a depth of 15cm in a soybean field at the Central Experiment Farm in Ottawa, Ontario. Samples will be removed at intervals of 1,2,3,6,9,12, and 15 months, and the δ13C of three soil fractions will be examined to reveal changes in carbon storage over time. Our results will provide insights into the fate of carbon fixed during hydrogen coupled CO2 fixation, and demonstrate whether this CO2 fixation can contribute to the long-term greenhouse gas balance of soybean production systems.
Blomqvist, J E; Ahlborg, G; Isaksson, S; Svartz, K
1997-06-01
Two different methods of rigid fixation were compared for postoperative stability 6 months after mandibular advancement for treatment of Class II malocclusion. Sixty (30 + 30) patients from two different oral and maxillofacial units treated for a Class II malocclusion by bilateral saggital split osteotomy (BSSO), and two different methods of internal rigid fixation were prospectively investigated. Two groups (S1, n = 15; S2, n = 15) had bicortical noncompressive screws inserted in the gonial area through a transcutaneous approach, and the other two groups (P1, n = 15; P2, n = 15) had the bone segments fixed with unicortical screws and miniplates on the lateral surface of the mandibular body. Cephalograms were taken preoperatively, 2 days postoperatively and 6 months after the operation. A computer program was used to superimpose the three cephalograms and to register the mandibular advancement and postoperative change both sagittally and vertically. These were minor differences in the advancement and postoperative changes between the four groups, but statistically no significant difference was shown in either sagittal or vertical directions. However, statistically verified differences proved that increasing age was associated with a smaller amount of postsurgical relapse. Low-angle cases (ML/NSL < 25 degrees) had a bigger amount of surgical (P = .0008) and postsurgical (P = .0195) movement compared with the patients in the high-angle group (ML/NSL < 38 degrees). Using a multiple regression test, a positive correlation was also shown between the amount of surgical advancement and the amount of postsurgical instability (P = .018). This prospective dual-center study indicates that the two different methods of internal rigid fixation after surgical advancement of the mandible by BSSO did not significantly differ from each other, and it is up to the individual operator to choose the method for internal rigid fixation.
Villiers, M B; Villiers, C L; Jacquier-Sarlin, M R; Gabert, F M; Journet, A M; Colomb, M G
1996-01-01
Antigen opsonization by the C3b fragment of complement is a significant event in the modulation of cell-mediated immune response, but its mechanism is still largely unknown. The structural characteristics of C3b allow it to act as a bifunctional ligand between antigen and cells via their membrane C3b receptors. It was thus of interest to study the influence of the covalent link between C3b and antigen on the fixation and internalization of this antigen by antigen-presenting cells. Tetanus toxin (TT) was used as antigen, either free or covalently linked to C3b (TT-C3b). The antigen-presenting cells were TT-specific (4.2) or non-specific (BL15) Epstein-Barr virus (EBV)-transformed B cells. C3b was found to play an important role in antigen fixation and internalization by both antigen-specific and antigen non-specific cells. Covalent binding of C3b on TT (1) permitted fixation and internalization of this antigen by non-specific cells via their complement receptors; (2) enhanced antigen fixation and resulted in cross-linking between membrane immunoglobulins and complement receptors on antigen-specific cells. The consequences of covalent C3b binding to TT were analysed using antigen-specific and antigen-nonspecific cells. In both cases, a net increase in antigen fixation was observed. At the intracellular level, covalent C3b binding to TT resulted in a large TT incorporation in endosomes of nonspecific cells, similar to that observed in antigen-specific cells. Thus, C3b covalently linked to antigen enlarges the array of B-cell types capable of presenting antigen, including non-specific cells. Images Figure 2 PMID:8958046
Fixation and partitioning of heavy metals in slag after incineration of sewage sludge.
Chen, Tao; Yan, Bo
2012-05-01
Fixation of heavy metals in the slag produced during incineration of sewage sludge will reduce emission of the metals to the atmosphere and make the incineration process more environmentally friendly. The effects of incineration conditions (incineration temperature 500-1100°C, furnace residence time 0-60min, mass fraction of water in the sludge 0-75%) on the fixation rates and species partitioning of Cd, Pb, Cr, Cu, Zn, Mn and Ni in slag were investigated. When the incineration temperature was increased from 500 to 1100°C, the fixation rate of Cd decreased from 87% to 49%, while the fixation rates of Cu and Mn were stable. The maximum fixation rates for Pb and Zn and for Ni and Cr were reached at 900 and 1100°C, respectively. The fixation rates of Cu, Ni, Cd, Cr and Zn decreased as the residence time increased. With a 20min residence time, the fixation rates of Pb and Mn were low. The maximum fixation rates of Ni, Mn, Zn, Cu and Cr were achieved when the mass fraction of water in the sludge was 55%. The fixation rate of Cd decreased as the water mass fraction increased, while the fixation rate of Pb increased. Partitioning analysis of the metals contained in the slag showed that increasing the incineration temperature and residence time promoted complete oxidation of the metals. This reduced the non-residual fractions of the metals, which would lower the bioavailability of the metals. The mass fraction of water in the sludge had little effect on the partitioning of the metals. Correlation analysis indicated that the fixation rates of heavy metals in the sludge and the forms of heavy metals in the incinerator slag could be controlled by optimization of the incineration conditions. These results show how the bioavailability of the metals can be reduced for environmentally friendly disposal of the incinerator slag. Copyright © 2011 Elsevier Ltd. All rights reserved.
Methanotrophy Induces Nitrogen Fixation in Boreal Mosses
NASA Astrophysics Data System (ADS)
Tiirola, M. A.
2014-12-01
Many methanotrophic bacterial groups fix nitrogen in laboratory conditions. Furthermore, nitrogen (N) is a limiting nutrient in many environments where methane concentrations are highest. Despite these facts, methane-induced N fixation has previously been overlooked, possibly due to methodological problems. To study the possible link between methanotrophy and diazotrophy in terrestrial and aquatic habitats, we measured the co-occurrence of these two processes in boreal forest, peatland and stream mosses using a stable isotope labeling approach (15 N2 and 13 CH4 double labeling) and sequencing of the nifH gene marker. N fixation associated with forest mosses was dependent on the annual N deposition, whereas methane stimulate N fixation neither in high (>3 kg N ha -1 yr -1) nor low deposition areas, which was in accordance with the nifH gene sequencing showing that forest mosses (Pleurozium schreberi and Hylocomium splendens ) carried mainly cyanobacterial N fixers. On the other extreme, in stream mosses (Fontinalis sp.) methane was actively oxidized throughout the year, whereas N fixation showed seasonal fluctuation. The co-occurrence of the two processes in single cell level was proven by co-localizing both N and methane-carbon fixation with the secondary ion mass spectrometry (SIMS) approach. Methanotrophy and diazotrophy was also studied in peatlands of different primary successional stages in the land-uplift coast of Bothnian Bay, in the Siikajoki chronosequence, where N accumulation rates in peat profiles indicate significant N fixation. Based on experimental evidence it was counted that methane-induced N fixation explained over one-third of the new N input in the younger peatland successional stages, where the highest N fixation rates and highest methane oxidation activities co-occurred in the water-submerged Sphagnum moss vegetation. The linkage between methanotrophic carbon cycling and N fixation may therefore constitute an important mechanism in the rapid accumulation of N during the primary succession of peatlands. It is still an open issue whether methanotrophy induces N fixation directly or by enhancing phototrophic or heterotrophic N fixation.
Nagura, Issei; Fujioka, Hiroyuki; Kurosaka, Masahiro; Mori, Hiroyuki; Mitani, Makoto; Ozaki, Akihiro; Fujii, Hideo; Nabeshima, Yuji
2012-01-01
Calcaneal avulsion fractures are not uncommon, and they are probably more likely in patients with osteoporosis. Closed manipulation for this type of fracture often fails to achieve acceptable reduction, and open reduction and internal fixation are usually required. However, open reduction and internal fixation with either a lag screw or Steinmann pins do not provide satisfactory fixation in patients with diabetes and elderly patients because of the presence of porotic bone. Levi described a tension band fixation system used to treat a calcaneal avulsion fracture using a simple technique performed with a transverse Kirschner wire through the os calcaneus, securing a figure-of-8 metal tension band wiring to the fragment. We report the successful treatment of 3 patients with calcaneal avulsion fractures using a modified tension band wiring technique, resulting in satisfactory recovery. Re-displacement of the fragment during the initial follow-up period was not reported, and bony union was achieved in all patients. We believe this technique is a useful surgical option for the treatment of calcaneal avulsion fractures. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Necrotizing fasciitis after internal fixation of fracture of femoral trochanteric☆☆☆
Santos, Leandro Emílio Nascimento; Pires, Robinson Esteves Santos; Figueiredo, Leonardo Brandão; Soares, Eduardo Augusto Marques
2014-01-01
Necrotizing fasciitis is a rare and potentially lethal soft tissue infection. We report a case of trochanteric femur fracture in a patient who underwent fracture fixation and developed necrotizing fasciitis. A literature review on the topic will be addressed. PMID:26229777
Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures.
Taylor, Benjamin C; Hansen, Dane C; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel
2016-01-01
Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted.
Ye, Dongmei; Xu, Yiming; Zhang, Han; Fu, Tengfei; Jiang, Lan; Bai, Yuehong
2013-01-01
Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tissues. Comparing with traditional medical stainless steel, titanium alloy is a kind of medical implants with low magnetic permeability and electric conductivity. But the effects of microwave treatment on fracture with titanium alloy internal fixation in vivo were not reported. The aim of this article was to evaluate the security and effects of microwave on healing of a fracture with titanium alloy internal fixation. Titanium alloy internal fixation systems were implanted in New Zealand rabbits with a 3.0 mm bone defect in the middle of femur. We applied a 30-day microwave treatment (2,450MHz, 25W, 10 min per day) to the fracture 3 days after operation. Temperature changes of muscle tissues around implants were measured during the irradiation. Normalized radiographic density of the fracture gap was measured on the 10th day and 30th day of the microwave treatment. All of the animals were killed after 10 and 30 days microwave treatment with histologic and histomorphometric examinations performed on the harvested tissues. The temperatures did not increase significantly in animals with titanium alloy implants. The security of microwave treatment was also supported by histology of muscles, nerve and bone around the implants. Radiographic assessment, histologic and histomorphometric examinations revealed significant improvement in the healing bone. Our results suggest that, in the healing of fracture with titanium alloy internal fixation, a low dose of microwave treatment may be a promising method.
Zhang, Han; Fu, Tengfei; Jiang, Lan; Bai, Yuehong
2013-01-01
Background Microwave is a method for improving fracture repair. However, one of the contraindications for microwave treatment listed in the literature is surgically implanted metal plates in the treatment field. The reason is that the reflection of electromagnetic waves and the eddy current stimulated by microwave would increase the temperature of magnetic implants and cause heat damage in tissues. Comparing with traditional medical stainless steel, titanium alloy is a kind of medical implants with low magnetic permeability and electric conductivity. But the effects of microwave treatment on fracture with titanium alloy internal fixation in vivo were not reported. The aim of this article was to evaluate the security and effects of microwave on healing of a fracture with titanium alloy internal fixation. Methods Titanium alloy internal fixation systems were implanted in New Zealand rabbits with a 3.0 mm bone defect in the middle of femur. We applied a 30-day microwave treatment (2,450MHz, 25W, 10 min per day) to the fracture 3 days after operation. Temperature changes of muscle tissues around implants were measured during the irradiation. Normalized radiographic density of the fracture gap was measured on the 10th day and 30th day of the microwave treatment. All of the animals were killed after 10 and 30 days microwave treatment with histologic and histomorphometric examinations performed on the harvested tissues. Findings The temperatures did not increase significantly in animals with titanium alloy implants. The security of microwave treatment was also supported by histology of muscles, nerve and bone around the implants. Radiographic assessment, histologic and histomorphometric examinations revealed significant improvement in the healing bone. Conclusion Our results suggest that, in the healing of fracture with titanium alloy internal fixation, a low dose of microwave treatment may be a promising method. PMID:24086626
Morelli, Moreno; Poitras, Philippe; Grimes, Valentine; Backman, David; Dervin, Geoffrey
2007-04-01
The purpose of this study was to determine what characteristics of fixation devices used in the treatment of osteochondritis dissecans (OCD) contribute to improved stability to resist shear loading. An OCD model was designed using rigid polyurethane foam. Each specimen consisted of two components, an osteochondral fragment and a corresponding defect. A total of 40 specimens were prepared and assigned to one of four groups: control (no extrinsic stabilizer); two 2-mm-diameter Kirschner wires (K-wires), 40 mm in length; one threaded washer and a 28-mm screw; and one threaded washer and a 38 mm screw. Each specimen was mounted onto an Iosipescu shear test fixture and subjected to shear loads at a pseudo-static displacement rate of 0.075 mm/s. All groups demonstrated some stability; controls were significantly less stable than all other groups. The group with the threaded washer and 38-mm screw demonstrated the greatest stability (p < 0.001), and no difference was noted between the K-wire and 28-mm screw groups. These results suggest that, in this OCD model, friction conferred some intrinsic stability to resist loads in shear. However, stability was improved with the use of long implants that compressed the fragments together.
Wang, Chaoliang; Huang, Sufang; Wang, Yingzhen; Sun, Xuesheng; Zhu, Tao; Li, Qiang; Lin, Chu
2015-01-01
We evaluated the long-term clinical results of acute complete acromioclavicular dislocations treated by reconstruction of the acromioclavicular and coracoclavicular ligament using trapezius muscle fascia. Open reduction and internal fixation was performed using the clavicular hook plate in 12 patients with acute complete acromioclavicular joint dislocation, and the acromioclavicular and coracoclavicular ligaments were reconstructed using trapezius muscle fascia. Radiographic evaluations were conducted postoperatively. We evaluated the functional results with constant scoring system and radiological results at the final follow-up visit. The mean Constant score at the final follow-up visit was 91.67 (range, 81 to 100). The results were excellent in eight patients (66.7%) and good in four patients (33.3%). Three patients with scores from 80 to 90 had mild pain during activity, but this did not affect the range of motion of the shoulder. All patients have returned to their preoperative work without any limitations. Compared with the contralateral side, radiography showed anatomical reposition in the vertical plane in all cases. The hook-plate fixation with ligament reconstruction was successful in treating AC dislocations. The acromioclavicular and coracoclavicular ligament were reconstructed by trapezius muscle fascia that keep the distal clavicle stable both vertically and horizontally after type III injuries.
Wang, Chaoliang; Huang, Sufang; Wang, Yingzhen; Sun, Xuesheng; Zhu, Tao; Li, Qiang; Lin, Chu
2015-01-01
We evaluated the long-term clinical results of acute complete acromioclavicular dislocations treated by reconstruction of the acromioclavicular and coracoclavicular ligament using trapezius muscle fascia. Open reduction and internal fixation was performed using the clavicular hook plate in 12 patients with acute complete acromioclavicular joint dislocation, and the acromioclavicular and coracoclavicular ligaments were reconstructed using trapezius muscle fascia. Radiographic evaluations were conducted postoperatively. We evaluated the functional results with constant scoring system and radiological results at the final follow-up visit. The mean Constant score at the final follow-up visit was 91.67 (range, 81 to 100). The results were excellent in eight patients (66.7%) and good in four patients (33.3%). Three patients with scores from 80 to 90 had mild pain during activity, but this did not affect the range of motion of the shoulder. All patients have returned to their preoperative work without any limitations. Compared with the contralateral side, radiography showed anatomical reposition in the vertical plane in all cases. The hook-plate fixation with ligament reconstruction was successful in treating AC dislocations. The acromioclavicular and coracoclavicular ligament were reconstructed by trapezius muscle fascia that keep the distal clavicle stable both vertically and horizontally after type III injuries. PMID:28352721
Stabilization of an acetabular fracture with cables for acute total hip arthroplasty.
Mears, D C; Shirahama, M
1998-01-01
A critical stage of total hip arthroplasty for an acute acetabular fracture where extensive comminution, impaction, and osteopenia thwart the application of conventional open or closed methods, especially in the elderly, is stable fixation of the acetabulum. The use of 2-mm braided cables permits effective immobilization of the fracture for use in conjunction with a hybrid arthroplasty. The method is consistent with the use of a conventional arthroplastic incision and is suitable for other applications including the fixation of periprosthetic fractures, bulk allografts, and conventional acetabular fractures.
[Multiple fractures of the lower extremities (a propos of 50 patients)].
Touzard, R C; Kudela, I
1975-04-01
According to a study of 50 multiple fractures of the lower limbs, the frequency of associated lesions justifies the creation of new multiple injury units, well equipped in which may be found specialists of all branches of surgery. Although internal fixation in one stage as an emergency, is ideal in all fractures, one should in fact be circumspect for the danger of infection should lead one to avoid carrying out internal fixation if this is not absolutely necessary.
Significance of fixation of the vertebral column for spinal cord injury experiments.
Liu, Fei; Luo, Zhuo-Jin; You, Si-Wei; Jiao, Xi-Ying; Meng, Xiao-Mei; Shi, Ming; Wang, Chun-Ting; Ju, Gong
2003-08-01
Thoracic spinal cord transections were performed in adult rats. The animals were divided into two groups, with or without internal fixation of the involved vertebral column. Histologic and immunohistochemical studies were performed to compare the effect of internal fixation of the vertebral column. To find out the aspects and extent of beneficial effects of vertebral column fixation for spinal cord repair. Vertebral column fixation is a routine procedure in clinical spinal cord surgery. Paradoxically, most, if not all, animal spinal cord experiments seem to have ignored the importance of vertebral column fixation. During trunk movements, the vertebral column flexes to different directions, accompanied by bending of the spinal cord. Following spinal cord lesions, with frequent bending of the cord there will be repeated bleeding, inflammation, and other pathologic processes at the lesion site. Thus, the healing process will be hampered. The severity of the damages that will be brought about by bending of the cord is, to a certain degree, unpredictable. There will be rather big individual variations in injury and repair among the same type of experiments, rendering quantification and conclusion difficult. Adult Sprague-Dawley rats were used. The thoracic spinal cord was transected. Strong stainless steel wires were used for internal fixation of the vertebral column. The histology of the horizontal sections of the spinal cord segment, which included the lesion site, was examined at the 14th postoperative day. The volumes of the secondary degeneration and meningeal scar, the gap between the borders of the proximal and distal stumps of the transected spinal cord, the thickness of the meningeal scar, the astrocytic reaction, and the abundance of regenerating nerve fibers at the lesion site were compared between the vertebral column fixed and nonfixed groups. Whenever possible, the results were evaluated quantitatively. In all these aspects, the internally fixed group was consistently far better than the unfixed group. The quantitative analyses were as follows (fixed/unfixed): 1)volume of secondary degeneration: 1.07 +/- 0.20/1.81 +/- 0.43 mm3 (P < 0.01); 2) volume of meningeal scar: 2.38 +/- 0.55/4.34 +/- 1.40 mm3 (P < 0.05); 3) distance between cord stumps: 1.38 +/- 0.34/2.35 +/- 0.79 mm (P < 0.05); 4) the mean thinnest dimension of the meningeal scar: 0.90 +/- 0.43/1.98 +/- 0.85 mm (P < 0.05). Vertebral column fixation is a crucial procedure for spinal cord animal experiments.
Knee arthrodesis with the Sheffield external ring fixator: fusion in 6 of 10 consecutive patients.
Ulstrup, Anton K; Folkmar, Klaus; Broeng, Leif
2007-06-01
Knee arthrodesis with external fixation (XF) is a possible salvage procedure for infected total knee arthroplasties (TKA). We report the outcome in 10 patients who underwent arthrodesis with the Sheffield Ring Fixator. The patients had primary arthrosis in 8 cases; 2 cases were due to rheumatoid arthritis and sclerodermia. The mean time between the primary TKA and arthrodesis was 6 (0.5-14) years. The average age at arthrodesis was 69 years. The average follow-up period was 10 months. Stable fusion was obtained in 6 patients after a mean XF time of 3.6 (2-4) months. 1 patient was referred to another hospital because of nonunion. This patient showed fusion with intramedullary nailing after 7 months. 3 nonunion patients required permanent bracing. 7 patients had pin tract infections. Infections healed in all patients. The Sheffield Ring Fixator gives an acceptable fusion rate for arthrodesis in the infected TKA, with limited complications.
Gaze behavior predicts memory bias for angry facial expressions in stable dysphoria.
Wells, Tony T; Beevers, Christopher G; Robison, Adrienne E; Ellis, Alissa J
2010-12-01
Interpersonal theories suggest that depressed individuals are sensitive to signs of interpersonal rejection, such as angry facial expressions. The present study examined memory bias for happy, sad, angry, and neutral facial expressions in stably dysphoric and stably nondysphoric young adults. Participants' gaze behavior (i.e., fixation duration, number of fixations, and distance between fixations) while viewing these facial expressions was also assessed. Using signal detection analyses, the dysphoric group had better accuracy on a surprise recognition task for angry faces than the nondysphoric group. Further, mediation analyses indicated that greater breadth of attentional focus (i.e., distance between fixations) accounted for enhanced recall of angry faces among the dysphoric group. There were no differences between dysphoria groups in gaze behavior or memory for sad, happy, or neutral facial expressions. Findings from this study identify a specific cognitive mechanism (i.e., breadth of attentional focus) that accounts for biased recall of angry facial expressions in dysphoria. This work also highlights the potential for integrating cognitive and interpersonal theories of depression.
Suture Anchors Fixation in MPFL Reconstruction using a Bioactive Synthetic Ligament
Berruto, Massimo; Ferrua, Paolo; Tradati, Daniele; Uboldi, Francesco; Usellini, Eva; Marelli, Bruno Michele
2017-01-01
Medial patellofemoral ligament (MPFL) reconstruction has a key role in patellofemoral instability surgery. Many surgical techniques have been described so far using different types of grafts (autologous, heterologous, or synthetic) and fixation techniques. The hereby described technique for MPFL reconstruction relies on the use of a biosynthetic graft (LARS Arc Sur Tille, France). Fixation is obtained by means of suture anchors on the patellar side and a resorbable interference screw on the femoral side locating the insertion point according to Schottle et al. An early passive range of motion (ROM) recovery is fundamental to reduce the risk of postoperative stiffness; a partial weight bearing with crutches is allowed until 6 weeks after the surgery. In our experience, the use of a biosynthetic graft and suture anchors provides stable fixation, minimizing donor site morbidity and reducing the risk of patellar fracture associated with transosseous tunnels. This technique represents a reliable and reproducible alternative for MPFL reconstruction, thereby minimizing the risk of possible complications. PMID:29270552
Bhandari, Mohit; Tornetta, Paul; Ellis, Thomas; Audige, Laurent; Sprague, Sheila; Kuo, Jonathann C; Swiontkowski, Marc F
2004-01-01
There have been a number of non-randomized studies comparing arthroplasty with internal fixation in patients with femoral neck fractures. However, there remains considerable debate about whether the results of non-randomized studies are consistent with the results of randomized, controlled trials. Given the economic burden of hip fractures, it remains essential to identify therapies to improve outcomes; however, whether data from non-randomized studies of an intervention should be used to guide patient care remains unclear. We aimed to determine whether the pooled results of mortality and revision surgery among non-randomized studies were similar to those of randomized trials in studies comparing arthroplasty with internal fixation in patients with femoral neck fractures. We conducted a Medline search from 1969 to June 2002, identifying both randomized and non-randomized studies comparing internal fixation with arthroplasty in patients with femoral neck fractures. Additional strategies to identify relevant articles included Cochrane database, SCISEARCH, textbooks, annual meeting programs, and content experts. We abstracted information on mortality and revision rates in each study and compared the pooled results between non-randomized and randomized studies. In addition, we explored potential reasons for dissimilar results between the two study designs. We identified 140 citations that addressed the general topic of comparison of arthroplasty and internal fixation for hip fracture. Of these, 27 studies met the eligibility criteria, 13 of which were non-randomized studies and 14 of which were randomized trials. Mortality data was available in all 13 non-randomized studies ( n=3108 patients) and in 12 randomized studies ( n=1767 patients). Non-randomized studies overestimated the risk of mortality by 40% when compared with the results of randomized trials (relative risk 1.44 vs 1.04, respectively). Information on revision risk was available in 9 non-randomized studies ( n=2764 patients) and all 14 randomized studies ( n=1901 patients). Both estimates from non-randomized and randomized studies revealed a significant reduction in the risk of revision surgery with arthroplasty compared with internal fixation (relative risk 0.38 vs 0.23, respectively). The reduction in the risk of revision surgery with arthroplasty compared with internal fixation was 62% for non-randomized studies and 77% for randomized trials. Thus, non-randomized studies underestimated the relative benefit of arthroplasty by 19.5%. Non-randomized studies with point estimates of relative risk similar to the pooled estimate for randomized trials all controlled for patient age, gender, and fracture displacement in their comparisons of mortality. We were unable to identify reasons for differences in the revision rate results between the study designs. Similar to other reports in medical subspecialties, non-randomized studies provided results dissimilar to randomized trials of arthroplasty vs internal fixation for mortality and revision rates in patients with femoral neck fractures. Investigators should be aware of these discrepancies when evaluating the merits of alternative surgical interventions, especially when both randomized trials and non-randomized comparative studies are available.
Kennedy Space Center Fixation Tube (KFT)
NASA Technical Reports Server (NTRS)
Richards, Stephanie E.; Levine, Howard G.; Romero, Vergel
2016-01-01
Experiments performed on the International Space Station (ISS) frequently require the experimental organisms to be preserved until they can be returned to earth for analysis in the appropriate laboratory facility. The Kennedy Fixation Tube (KFT) was developed to allow astronauts to apply fixative, chemical compounds that are often toxic, to biological samples without the use of a glovebox while maintaining three levels of containment (Fig. 1). KFTs have been used over 200 times on-orbit with no leaks of chemical fixative. The KFT is composed of the following elements: a polycarbonate main tube where the fixative is loaded preflight, the sample tube where the plant or other biological specimens is placed during operations, the expansion plug, actuator, and base plug that provides fixative containment (Fig. 2). The main tube is pre-filled with 25 mL of fixative solution prior to flight. When actuated, the specimen contained within the sample tube is immersed with approximately 22 mL (+/- 2 mL) of the fixative solution. The KFT has been demonstrated to maintain its containment at ambient temperatures, 4degC refrigeration and -100 C freezing conditions.
Vascular risk reduction during anterior surgical approach sacroiliac joint plating.
Alla, Sreenivasa R; Roberts, Craig S; Ojike, Nwakile I
2013-02-01
Open reduction and internal fixation of sacroiliac (SI) joint is often performed through an anterior approach. However, there were no studies to our knowledge which described the "at risk area" for injury to the nutrient artery as it relates to open reduction and internal fixation of the SI joint. The purpose of this study was to determine the "at risk area" for the nutrient artery during anterior surgical approaches to the SI joint and to define the safe location of the plate for SI joint fixation. Six right and five left hemipelvises (three male and three female cadavers) were dissected with a mean age of 72 years (range, 51-90 years). Three bony landmarks including the pelvic brim, anterior SI joint line, and the anterior superior iliac spine (ASIS) were identified to quantify the measurements. Three different measurements were taken: from the nutrient foramen to the anterior SI joint line; from the nutrient foramen to the nearest point on the pelvic brim; from the nutrient foramen to ASIS using a flexible ruler with a 1mm base. The nutrient artery courses across the SI joint to enter into the nutrient foramen. Whilst exposing the internal surface of the SI joint, the nutrient foramen was identified at a mean distance of 88.1mm medial to ASIS, 20.1mm above the pelvic brim, and 20.1mm lateral to SI joint. The variability of the location of the nutrient foramen was identified and was located from 80mm to 95mm medial to the ASIS, 12mm to 25mm lateral to the SI joint, and 16mm to 30mm above the pelvic brim. Familiarity of the vasculature of the internal pelvis is of utmost importance for the surgeon when considering operative fixation of the anterior SI joint. We were able to identify the relation of the nutrient artery to the anatomic landmarks of the internal pelvis and to define the "at risk area" for the nutrient artery. We believe increased understanding of the anatomy of the nutrient artery will aid in the avoidance of vascular complications during internal fixation of the anterior SI joint. Copyright © 2012 Elsevier Ltd. All rights reserved.
Hong, Choon Chiet; Nag, Kushal; Yeow, Huifen; Lin, Adrian Zhigao; Tan, Ken Jin
2018-05-17
Fifth metatarsal tuberosity avulsion fractures are common. Despite good outcomes with nonoperative treatment, acute fractures with displacement, intra-articular involvement, comminution, or painful nonunion have been reported to benefit from early open reduction and internal fixation, especially in athletes. No consensus has been reached regarding the best surgical fixation technique. We present a case series of 4 patients with displaced fifth metatarsal tuberosity avulsion fractures and an innovative technique of fixation for the tuberosity avulsion fractures using a suture anchor. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Havlůj, L; Džupa, V; Gürlich, R
2017-01-01
Current polytrauma management is multidisciplinary, with Damage Control Surgery (DCS), Damage Control Orthopaedics (DCO) and Damage Control Resuscitation (DCR) being applied in the first few hours after injury. The most severe group of polytrauma patients are those with circulatory instability and massive blood loss as a consequence of unstable pelvic fractures. In treating these patients, of crucial importance is the speed and quality of stabilisation of pelvic fracture fragments. The authors present two case reports of polytrauma patients with unstable pelvic fractures, in whom open reduction and internal fixation was performed on the anterior fracture segment through extended laparotomy in order to stop bleeding into the abdominopelvic cavity as part of the DCS approach. Key words: exsanguination, polytrauma, unstable pelvic fracture, plate fixation.
Zhao, Wenbo; Tu, Chongqi; Zhang, Hui; Fang, Yue; Wang, Guanglin; Liu, Lei
2014-04-01
To compare the effects and security between internal fixation and total hip arthroplasty for the patients in elderly with femoral neck fracture of displacement type through a meta analysis. Studies on comparison between internal fixation and total hip arthroplasty for the patients in the elderly with femoral neck fracture of displacement type were identified from PubMed database,EMBase database, COCHRANE library, CMB database, CNKI database and MEDLINE database. Data analysis were performed using Revman 5.2.6(the Cochrane Collaboration). Six published randomized controlled trials including 627 patients were suitable for the review, 286 cases in internal fixation group and 341 cases in total hip arthroplasty group. The results of meta analysis indicated that statistically significant difference were observed between the two groups in the quality of life which was reflected by the Harris scale (RR = 0.82, 95%CI:0.72-0.93, P < 0.05) , the reoperation rate (RR = 5.81, 95%CI:3.09-10.95, P < 0.05) and the major complications rate (RR = 3.60, 95%CI:2.29-5.67, P < 0.05) postoperatively. There were no difference in the mortality at 1 year and 5 years postoperatively(P > 0.05). For the patients with femoral neck fracture of displacement type in the elderly, there is no statistical difference between two groups in the mortality postoperatively. The quality of life and the security of operation in internal fixation group is worse than the total hip arthroplasty group.
Panchal, Ripul R; Matheis, Erika A; Gudipally, Manasa; Hussain, Mir M; Kim, Kee D; Bucklen, Brandon S
2015-10-01
Traditional reconstruction for burst fractures involves columnar support with posterior fixation at one or two levels cephalad/caudad; however, some surgeons choose to only stabilize the vertebral column. The aim was to distinguish biomechanical differences in stability between a burst fracture stabilized through a lateral approach using corpectomy spacers of different end plate sizes with and without integrated screws and with and without posterior fixation. This was an in vitro biomechanical study assessing thoracolumbar burst fracture stabilization. Six human spines (T11-L3) were tested on a six-degrees-of-freedom simulator enabling unconstrained range of motion (ROM) at ±6 N·m in flexion-extension (FE), lateral bending (LB), and axial rotation (AR) after a simulated burst fracture at L1. Expandable corpectomy spacers with/without integrated screws (Fi/F; FORTIFY Integrated/FORTIFY; Globus Medical, Inc., Audubon, PA, USA) were tested with different end plate sizes (21×23 mm, 22×40-50 mm). Posterior instrumentation (PI) via bilateral pedicle screws and rods was used one level above and one level below the burst fracture. Lateral plate (LP) fixation was tested. Devices were tested in the following order: intact; Fi21×23; Fi21×23+PI; F21×23+PI+LP; F21×23+LP; F22×40-50+LP; F22×40-50+PI+LP; Fi22×40-50+PI; Fi22×40-50. In FE and AR, constructs without PI showed no significant difference (p<.05) in stability compared with intact. In LB, F22×40-50+LP showed a significant increase in stability relative to intact, but no other construct without PI reached significance. In FE and LB, circumferential constructs were significantly more stable than intact. In AR, no construct showed significant differences in motion when compared with the intact condition. Constructs without posterior fixation were the least stable of all tested constructs. Circumferential fixation provided greater stability in FE and LB than lateral fixation and intact. Axial rotation showed no significant differences in any construct compared with the intact state. Copyright © 2015 Elsevier Inc. All rights reserved.
Biomechanical analysis of posteromedial tibial plateau split fracture fixation.
Zeng, Zhi-Min; Luo, Cong-Feng; Putnis, Sven; Zeng, Bing-Fang
2011-01-01
The purpose of this study was to compare the biomechanical strength of four different fixation methods for a posteromedial tibial plateau split fracture. Twenty-eight tibial plateau fractures were simulated using right-sided synthetic tibiae models. Each fracture model was randomly instrumented with one of the four following constructs, anteroposterior lag-screws, an anteromedial limited contact dynamic compression plate (LC-DCP), a lateral locking plate, or a posterior T-shaped buttress plate. Vertical subsidence of the posteromedial fragment was measured from 500 N to 1500 N during biomechanical testing, the maximum load to failure was also determined. It was found that the posterior T-shaped buttress plate allowed the least subsidence of the posteromedial fragment and produced the highest mean failure load than each of the other three constructs (P=0.00). There was no statistical significant difference between using lag screws or an anteromedial LC-DCP construct for the vertical subsidence at a 1500 N load and the load to failure (P>0.05). This study showed that a posterior-based buttress technique is biomechanically the most stable in-vitro fixation method for posteromedial split tibial plateau fractures, with AP screws and anteromedial-based LC-DCP are not as stable for this type of fracture. Copyright © 2010 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jennings, Ryan de Montmollin; Moran, James J.; Jay, Zackary J.
Biological fixation of CO 2 is the primary mechanism of C reduction in natural systems, and provides a diverse suite of organic compounds utilized by chemoorganoheterotrophs. The extent and mechanisms of CO 2 fixation were evaluated across a comprehensive set of high-temperature, chemotrophic microbial communities in Yellowstone National Park by combining metagenomic and stable 13C isotope analyses. Fifteen geothermal sites representing three distinct habitat types (iron-oxide mats, anoxic sulfur sediments, and filamentous ‘streamer’ communities) were investigated. Genes of the 3-hydroxypropionate/4-hydroxybutyrate, dicarboxylate/4-hydroxybutyrate, and reverse tricarboxylic acid CO 2 fixation pathways were identified in assembled genome sequence corresponding to the predominant Crenarchaeotamore » and Aquificales observed across this habitat range. Stable 13C analyses of dissolved inorganic and organic C (DIC, DOC), and possible landscape C sources were used to interpret the 13C content of microbial community samples. Isotope mixing models showed that the minimum amounts of autotrophic C in microbial biomass were > 50 % in the majority of communities analyzed, but were also dependent on the amounts of heterotrophy and/or accumulation of landscape C. Furthermore, the significance of CO 2 as a C source in these communities provides a foundation for understanding metabolic linkages among autotrophs and heterotrophs, community assembly and succession, and the likely coevolution of deeply-branching thermophiles.« less
Besch, D; Sachs, H; Szurman, P; Gülicher, D; Wilke, R; Reinert, S; Zrenner, E; Bartz-Schmidt, K U; Gekeler, F
2008-10-01
Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.
Brattgjerd, Jan Egil; Loferer, Martin; Niratisairak, Sanyalak; Steen, Harald; Strømsøe, Knut
2018-06-01
In undisplaced femoral neck fractures, internal fixation remains the main treatment, with mechanical failure as a frequent complication. As torsional stable fixation promotes femoral neck fracture healing, the Hansson Pinloc® System with a plate interlocking pins, was developed from the original hook pins. Since its effect on torsional stability is undocumented, the novel implant was compared with the original configurations. Forty-two proximal femur models custom made of two blocks of polyurethane foam were tested. The medial block simulated the cancellous head, while the lateral was laminated with a glass fiber filled epoxy sheet simulating trochanteric cortical bone. Two hollow metal cylinders with a circumferential ball bearing in between mimicked the neck, with a perpendicular fracture in the middle. Fractures were fixated by two or three independent pins or by five configurations involving the interlocking plate (two pins with an optional peg in a small plate, or three pins in a small, medium or large plate). Six torsional tests were performed on each configuration to calculate torsional stiffness, torque at failure and failure energy. The novel configurations improved parameters up to an average of 12.0 (stiffness), 19.3 (torque) and 19.9 (energy) times higher than the original two pins (P < 0.001). The plate, its size and its triangular configuration improved all parameters (P = 0.03), the plate being most effective, also preventing permanent failure (P < 0.001). The novel plate design with its pin configuration enhanced torsional stability. To reveal clinical relevance a clinical study is planned. Copyright © 2018 Elsevier Ltd. All rights reserved.
Complex pelvic ring injuries associated with floating knee in a poly-trauma patient: A case report.
Zhou, Yuebin; Guo, Honggang; Cai, Zhiwei; Zhang, Yuan
2017-12-01
Complex pelvic ring fracture associated with floating knee is comparatively rare which usually results from high-energy trauma including vehicle-related accidence, falls from height, and earthquake-related injury. To our knowledge, few literatures have documented such injuries in the individual patient. Management of both injuries present challenges for surgical management and postoperative care. The purpose of this study is to prove the feasibility and benefits of damage control orthopedics (DCO). Our case involved a 45-year-old lady who was hit by a dilapidated building. The patient was anxious, pale and hemodynamically stable at the initial examination. The pelvis was unstable and there were obvious deformities in the left lower extremities. Significant degloved injuries in the left leg were noted. Her radiographs and physical examination verified the above signs. Unstable pelvic fractures, multiple fractures of bilateral lower limbs with floating knee injury, multiple pelvic and rib fractures and multiple degloving injuries and soft tissue contusion formed the characteristics of the multiple-injury. The algorithm of DCO was determined as the treatment. Early simplified procedures such as wound debridement, pelvis fixation, closed reduction and EF of the right shoulder joint, and chest wall fixation were conducted as soon as possible. After a period of time, internal fixations were applied to the fracture sites. The subsequent functional exercise was also conducted in accordance with this algorithm. This patient got recovery after the treatments which were guided by the criterion of DCO. The restoration of limb functional and the quality of life greatly improved. The DCO plays a decisive role in the first aid and follow-up treatment of this patient. The guidelines of management of complex pelvic ring injuries and floating knee should be established by authorities.
Gueorguiev, Boyko; Wähnert, Dirk; Albrecht, Daniel; Ockert, Ben; Windolf, Markus; Schwieger, Karsten
2011-02-01
Unstable distal tibia fractures are challenging injuries that require surgery. Increasingly, intramedullary nails are being used. However, fracture site anatomy may cause distal-fragment stabilization and fixation problems and lead to malunion/nonunion. We studied the influence of angle-stable nail locking on fracture gap movement and other biomechanical parameters. Eight pairs of fresh human cadaver tibiae were used. The bone mineral density (BMD) was determined. All tibiae were nailed with a Synthes Expert tibial nail. Within each pair, one tibia was randomized to receive conventional locking screws; the other, angle-stable screws with sleeves. A 7-mm osteotomy was created 10 mm above the upper distal locking screw, to simulate an AO 42-A3 fracture. Biomechanical testing involved nondestructive mediolateral and anteroposterior pure bending, followed by cyclic combined axial and torsional loading to catastrophic failure. The neutral zone was determined. Fracture gap movement was monitored with 3-D motion tracking. The angle-stable locked constructs had a significantly smaller mediolateral neutral zone (mean: 0.04 degree; p=0.039) and significantly smaller fracture gap angulation (p=0.043). The number of cycles to failure did not differ significantly between the locking configurations. BMD was a significant covariate affecting the number of cycles to failure (p=0.008). However, over the first 20,000 cycles, there was no significant correlation in the angle-stable construct. Angle-stable locking of the Expert tibial nail was associated with a significant reduction in the mediolateral neutral zone and in fracture gap movement. Angle-stable fixation also reduced the influence of BMD over the first 20,000 cycles.
Yang, Yong-Jun; Zhang, En-Zhong; Tan, Yuan-Chao; Zhou, Ji-Ping; Yao, Shu-Qiang; Jiang, Chuan-Jie; Cong, Pei-Yan
2009-11-01
To investigate the clinical effect of atlantoaxial pedicle screw internal fixation for treatment of atlantoaxial dislocation. Sixteen patients with atlantoaxial dislocation were treated from Dec. 2005 to June 2007, included 10 males and 6 females, aged from 38 to 45 years old (means 40.5 years). Among them 12 patients combined with nerve injury, according to ASIA grade: there were 3 cases in grade B, 5 cases in grade C, 4 cases in grade D. All patients received preoperative CT, radiograph and skull traction. Intraoperative posterior approach general spine pedicle screw-rod orthopaedics fixation system used and iliac bone block were implanted in space of posterior atlantal arch and axial vertebral plate. The outcome and complications were observed in the near future. There was no vascular or neural injury found. The patients were followed up for 12 to 24 months (means 18 months). All head pain, acid storm symptoms were improved after operation. According to the Odom's clinical efficacy evaluation standard, 12 cases were excellent, 4 were good. Eleven cases of 12 with nerve injury recovered significantly. By ASIA classification: 1 cases was in grade B, 2 cases were in grade C, 5 cases were in grade D, 4 cases were in grade E. No looseness or breakage of screw occurred. Bony fusion was achieved in all cases. Posterior approach atlantoaxial pedicle screw internal fixation have the advantages of direct screw placement, short-segment fusion, intraoperative reduction, fixation reliable, high fusion rate, and it can restablish the upper cervical vertebrae stability and help to recover the spinal cord and nerve function.
Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures
Taylor, Benjamin C.; Hansen, Dane C.; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel
2016-01-01
Background Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. Methods In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Results Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. Conclusions This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted. PMID:27528840
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
Aird, J; Noor, S; Lavy, C; Rollinson, P
2011-05-01
There are 33 million people worldwide currently infected with human immunodeficiency virus (HIV). This complex disease affects many of the processes involved in wound and fracture healing, and there is little evidence available to guide the management of open fractures in these patients. Fears of acute and delayed infection often inhibit the use of fixation, which may be the most effective way of achieving union. This study compared fixation of open fractures in HIV-positive and -negative patients in South Africa, a country with very high rates of both HIV and high-energy trauma. A total of 133 patients (33 HIV-positive) with 135 open fractures fulfilled the inclusion criteria. This cohort is three times larger than in any similar previously published study. The results suggest that HIV is not a contraindication to internal or external fixation of open fractures in this population, as HIV is not a significant risk factor for acute wound/implant infection. However, subgroup analysis of grade I open fractures in patients with advanced HIV and a low CD4 count (< 350) showed an increased risk of infection; we suggest that grade I open fractures in patients with advanced HIV should be treated by early debridement followed by fixation at an appropriate time.
Corridors and some ecological and evolutionary consequences of connectivity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orrock, John L
2004-07-01
Abstract - By connecting disjunct patches, corridors may offset the effects of fragmentation by promoting gene flow and population persistence. However, the ultimate effect of corridors on a focal species may hinge upon two considerations: how corridors may affect ecological interactions that impinge upon that species, and how corridors might affect the fixation of novel alleles that ultimately determine fitness and persistence. Using an experimental landscape, I show that corridor-mediated changes in patch shape change seed predation in connected and unconnected patches, and shift the behavior, abundance, and distribution of seed predators. Rodent seed predators removed more seeds in connectedmore » patches, arthropod seed predators removed more seeds in rectangular patches, and avian seed predation did not differ due to patch type. Rodent foraging was greater in the interior of connected patches because changes in patch shape influenced risk perceived by rodents while foraging. Ant communities were also affected by changes in patch shape caused by corridors, rather than corridor effects per se. The distribution and abundance of ants differed among edge-rich areas (corridors and wings), edges, and the patch interior. In rectangular patches, fire ants (Solenopsis spp.) had negative impacts on other ant species. By changing the activity of rodents, and the composition of ant communities, corridors may have important impacts on seeds. Bird-dispersed seeds may benefit from increased dispersal among connected patches, but connected patches also have greater predation risk. Using a simulation model, I demonstrate that gene flow between a stable population and a population that experiences local extinction or a reduction in size (e.g. due to natural or anthropogenic disturbance) can dramatically affect fixation of alleles in the stable population. Alone or in concert, frequent disturbance, high rates of movement, and low habitat quality make it more likely that connectivity-mediated fixation will promote fixation of harmful alleles and reduce fixation of beneficial alleles.« less
Landgren, Marcus; Abramo, Antonio; Geijer, Mats; Kopylov, Philippe; Tägil, Magnus
2017-03-01
To compare the patient-reported, clinical, and radiographic outcome of 2 methods of internal fixation in distal radius fractures. Fifty patients, mean age 56 years (range, 21-69 years) with primarily nonreducible or secondarily redisplaced distal radius fractures were randomized to open reduction internal fixation using volar locking plates (n = 25) or fragment-specific fixation (n = 25). The patients were assessed on grip strength, range of motion, patient-reported outcome (Quick Disabilities of the Arm, Shoulder, and Hand), pain (visual analog scale), health-related quality of life (Short Form-12 [SF-12]), and radiographic evaluation. Grip strength at 12 months was the primary outcome measure. At 12 months, no difference was found in grip strength, which was 90% of the uninjured side in the volar plate group and 87% in the fragment-specific fixation group. No differences were found in range of motion and the median Quick Disabilities of the Arm, Shoulder, and Hand score was 5 in both groups. The overall complication rate was significant, 21% in the volar locking plate group, compared with 52% in the fragment-specific group. In treatment of primarily nonreducible or secondarily redisplaced distal radius fractures, volar locking plates and fragment-specific fixation both achieve good and similar patient-reported outcomes, although more complications were recorded in the fragment-specific group. Therapeutic II. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr; Gallo, Giacomo, E-mail: giacomo.gallo83@gmail.com; Bertrand, Anne-Sophie, E-mail: asbertrand3@hotmail.com
We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation couldmore » be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.« less
Management of complications of open reduction and internal fixation of ankle fractures.
Ng, Alan; Barnes, Esther S
2009-01-01
The management of complications resulting from the open reduction and internal fixation of ankle fractures is discussed in detail. The initial radiographic findings of the most common postsurgical complications of ankle fracture reduction are briefly discussed, namely lateral, medial, and posterior malleolar malunion or nonunion, syndesmotic widening, degenerative changes, and septic arthritis with or without concomitant osteomyelitis. Emphasis is placed on the management of these complications, with a review of the treatment options proposed in the literature, a detailed discussion of the authors' recommendations, and an inclusion of different case presentations.
2012-10-01
W81XWH-10-2-0093 TITLE: Use of the TRPV1 Agonist Capsaicin to Provide Long-Term Analgesia in a Rat Limb Fracture/Open Repair, Internal Fixation Model...2. REPORT TYPE Final 3. DATES COVERED (From - To) 30September2010-29September2012 4. TITLE AND SUBTITLE Use of the TRPV1 Agonist Capsaicin to...capsaicin around the fracture site. 15. SUBJECT TERMS Femur fracture, Rat Model, Pain, Capsaicin, Trauma, TRPV1 16. SECURITY CLASSIFICATION OF
Polycaprolactone/glass bioabsorbable implant in a rabbit humerus fracture model.
Lowry, K J; Hamson, K R; Bear, L; Peng, Y B; Calaluce, R; Evans, M L; Anglen, J O; Allen, W C
1997-09-15
Research in improved materials and methods for internal fixation has centered on internal fixators made of bioabsorbable materials such as polylactic acid, polyglycolic acid, and polyparadioxanone. These materials have two problems: the first is a postoperative complication related to a delayed inflammatory response; and the second is low strength characteristics. An alternative material developed to alleviate these problems is a composite of phosphate glass fibers embedded in the polymer polycaprolactone, referred to as PCL. In this study, intramedullary pins made of PCL were compared to stainless steel pins in a rabbit humerus osteotomy model. Specimens were harvested at 0, 6, and 12 weeks postoperatively, radiographs and mechanical testing to failure were performed at each time interval, and tissue was examined microscopically at 6 and 12 weeks. Histologic results showed PCL pins to be well tolerated with minimal inflammation around the pin. Mechanical testing revealed the PCL fixation to be weaker initially than the stainless steel fixation. There was significant stress shielding of stainless-steel-healed rabbit humeri when compared to the PCL/bone humeri. All osteotomies immobilized with PCL healed with abundant periosteal callus production.
Management of civilian ballistic fractures.
Seng, V S; Masquelet, A C
2013-12-01
The management of ballistic fractures, which are open fractures, has often been studied in wartime and has benefited from the principles of military surgery with debridement and lavage, and the use of external fixation for bone stabilization. In civilian practice, bone stabilization of these fractures is different and is not performed by external fixation. Fifteen civilian ballistic fractures, Gustilo II or IIIa, two associated with nerve damage and none with vascular damage, were reviewed. After debridement and lavage, ten internal fixations and five conservative treatments were used. No superficial or deep surgical site infection was noted. Fourteen of the 15 fractures (93%) healed without reoperation. Eleven of the 15 patients (73%) regained normal function. Ballistic fractures have a bad reputation due to their many complications, including infections. In civilian practice, the use of internal fixation is not responsible for excessive morbidity, provided debridement and lavage are performed. Civilian ballistic fractures, when they are caused by low-velocity firearms, differ from military ballistic fractures. Although the principle of surgical debridement and lavage remains the same, bone stabilization is different and is similar to conventional open fractures. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Shi, Chenglong; Pu, Xiaobing; Zheng, Guan; Feng, Xinglong; Yang, Xuan; Zhang, Baoliang; Zhang, Yu; Yin, Qingshui; Xia, Hong
2016-11-01
Implant-associated infections and non-absorbing materials are two important reasons for a second surgical procedure to remove internal fixation devices after an orthopedic internal fixation surgery. The objective of this study was to produce an antibacterial and absorbable fixation screw by adding gentamicin to silk-based materials. The antibacterial activity was assessed against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) in vitro by plate cultivation and scanning electron microscopy (SEM). We also investigated the properties, such as the mechanical features, swelling properties, biocompatibility and degradation, of gentamicin-loaded silk-based screws (GSS) in vitro. The GSS showed significant bactericidal effects against S. aureus and E. coli. The antibacterial activity remained high even after 4 weeks of immersion in protease solution. In addition, the GSS maintained the remarkable mechanical properties and excellent biocompatibility of pure silk-based screws (PSS). Interestingly, after gentamicin incorporation, the degradation rate and water-absorbing capacity increased and decreased, respectively. These GSS provide both impressive material properties and antibacterial activity and have great potential for use in orthopedic implants to reduce the incidence of second surgeries.
Arastu, Mateen; Sheehan, Brendan; Buckley, Richard
2014-03-01
The optimal treatment of calcaneal fractures is controversial. A specific subgroup of healthy patients has good outcomes with open reduction and internal fixation using an extensile lateral approach. However, there are many patients who do not fit into this category. Consequently, they are either denied surgical intervention or put at significant risk of developing complications as a result of open surgical intervention. Minimally invasive reduction and fixation (MIRF) of calcaneal fractures can restore the height, width, length and shape of the hindfoot in addition to restoring the orientation of the posterior facet of the calcaneus (Böhler's angle). We present a series of 31 patients treated with minimally invasive reduction and fixation technique using threaded K wires and Steinmann pins as an alternative treatment method in patients who are not suitable for open reduction and internal fixation. The mean time to surgery from injury was six days (range one to ten days). The mean duration of surgery was 35 minutes (range 11-52 minutes). The mean followup was 14.9 months (range of seven to 30 months). The mean change in Böhler's angle and length of the calcaneus from intra-operative fixation to final followup were 18.7° and 4.7 mm, respectively. The complication rate was low and there was one case of a superficial wound infection and no cases of deep infection or peroneal impingement in this series. The MIRF technique with the use of threaded K wires has not been previously described in the literature. In our experience, the operative time is short and can be safely performed even in the presence of extensive soft tissue swelling in the immediate period following injury. The infection risk is low and calcaneal morphology was improved and maintained in terms of Böhler's angle. This technique is suitable to be considered in patients who have significant medical co-morbidities (smokers, diabetics, peripheral vascular disease) and in those patients who are not suitable for an extensile lateral approach and internal fixation.
Carbon fixation in oceanic crust: Does it happen, and is it important?
NASA Astrophysics Data System (ADS)
Orcutt, B.; Sylvan, J. B.; Rogers, D.; Lee, R.; Girguis, P. R.; Carr, S. A.; Jungbluth, S.; Rappe, M. S.
2014-12-01
The carbon sources supporting a deep biosphere in igneous oceanic crust, and furthermore the balance of heterotrophy and autotrophy, are poorly understood. When the large reservoir size of oceanic crust is considered, carbon transformations in this environment have the potential to significantly impact the global carbon cycle. Furthermore, igneous oceanic crust is the most massive potential habitat for life on Earth, so understanding the carbon sources for this potential biosphere are important for understanding life on Earth. Geochemical evidence suggests that warm and anoxic upper basement is net heterotrophic, but the balance of these processes in cooler and potentially oxic oceanic crust are poorly known. Here, we present data from stable carbon isotope tracer incubations to examine carbon fixation in basalts collected from the Loihi Seamount, the Juan de Fuca Ridge, and the western flank of the Mid-Atlantic Ridge, to provide a first order constraint on the rates of carbon fixation on basalts. These data will be compared to recently available assessments of carbon cycling rates in fluids from upper basement to synthesize our current state of understanding of the potential for carbon fixation and respiration in oceanic crust. Moreover, we will present new genomic data of carbon fixation genes observed in the basalt enrichments as well as from the subsurface of the Juan de Fuca Ridge flank, enabling identification of the microbes and metabolic pathways involved in carbon fixation in these systems.
[Avulsion fracture of the calcaneal tuberosity in athletes].
Glanzmann, M; Veréb, L; Habegger, R
2005-04-01
Avulsion fractures of the calcaneal tuberosity are rare injuries. Several surgical treatment options have been described. The size of the calcaneal fragment is the limiting factor in choosing the method for restoration. Finding the right type of fixation modality remains challenging in this rare kind of injury. In the case presented one Mitek Super Anchor was used to reattach the small fragment of the tuberosity to the calcaneus. Stable fixation with bony reunion and excellent functional outcome were achieved by this technique within 10 weeks. Therefore, we recommend the use of an anchor system for the treatment of small fragment calcaneal avulsion fractures.
Jeong, Soon-Taek; Hwang, Sun-Chul; Kim, Dong-Hee; Nam, Dae-Cheol
2015-01-01
We introduce a case of traumatic dislocation of the posterior tibial tendon with avulsion fracture of the medial malleolus in a 52-year-old female patient who was treated surgically with periosteal flap and suture anchor fixation. Based in the posteromedial ridge of the distal tibia, a quadrilateral periosteal flap was created and folded over the tendon, followed by fixation on the lateral aspect of the groove by use of multiple suture anchors. Clinical and radiological findings 25 months postoperatively showed well-preserved function of the ankle joint with stable tendon gliding.
Kiene, J; Schulz, Arndt P; Hillbricht, S; Jürgens, Ch; Paech, A
2009-01-28
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations.
2009-01-01
The methods for ankle arthrodesis differ significantly, probably a sign that no method is clearly superior to others. In the last ten years there is a clear favour toward internal fixation. We retrospectively evaluate the technique and evaluate the clinical long term results of external fixation in a triangular frame. Patients and Methods From 1994 to 2001 a consecutive series of 95 patients with end stage arthritis of the ankle joint were treated. Retrospectively the case notes were evaluated regarding trauma history, medical complaints, further injuries and illnesses, walking and pain status and occupational issues and the clinical examination before arthrodesis. Mean age at the index procedure was 45.4 years (18-82), 67 patients were male (70.5%). Via a bilateral approach the malleoli and the joint surfaces were resected. An AO fixator was applied with two Steinmann-nails inserted with approximately 8 cm distance in the distal tibia, one in the neck of the talus and one in the dorsal calcaneus. The fixator was removed after approximately 12 weeks. Follow up examination at mean 4.4 years included a standardised questionnaire and a clinical examination including the criteria of the AOFAS-Score and radiographs. Results: Due to different complications, 8 (8.9%) further surgical procedures were necessary including 1 below knee amputation. In 4 patients a non-union of the ankle arthrodesis developed (4.5%). The mean AOFAS score improved from 20.8 to 69.3 points. Conclusion Non-union rates and clinical results of arthrodesis by triangular external fixation of the ankle joint do not differ to internal fixation methods. The complication rate and the reduced patient comfort reserve this method mainly for infected arthritis and complicated soft tissue situations. PMID:19258207
NASA Astrophysics Data System (ADS)
Hou, Lijun; Wang, Rong; Yin, Guoyu; Liu, Min; Zheng, Yanling
2018-03-01
Nitrogen fixation is a microbial-mediated process converting atmospheric dinitrogen gas to biologically available ammonia or other molecules, and it plays an important role in regulating nitrogen budgets in coastal marine ecosystems. In this study, nitrogen fixation in the intertidal sediments of the Yangtze Estuary was investigated using nitrogen isotope tracing technique. The abundance of nitrogen fixation functional gene (nifH) was also quantified. The measured rates of sediment nitrogen fixation ranged from 0.37 to 7.91 nmol N g-1 hr-1, while the abundance of nifH gene varied from 2.28 × 106 to 1.28 × 108 copies g-1 in the study area. The benthic nitrogen fixation was correlated closely to the abundance of nifH gene and was affected significantly by salinity, pH, and availability of sediment organic carbon and ammonium. It is estimated that sediment nitrogen fixation contributed approximately 9.3% of the total terrigenous inorganic nitrogen transported annually into the Yangtze estuarine and coastal environment. This result implies that the occurrence of benthic nitrogen fixation acts as an important internal source of reactive nitrogen and to some extent exacerbates nitrogen pollution in this aquatic ecosystem.
Factors Associated With Revision Surgery After Internal Fixation of Hip Fractures.
Sprague, Sheila; Schemitsch, Emil H; Swiontkowski, Marc; Della Rocca, Gregory J; Jeray, Kyle J; Liew, Susan; Slobogean, Gerard P; Bzovsky, Sofia; Heels-Ansdell, Diane; Zhou, Qi; Bhandari, Mohit
2018-05-01
Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (for every 5-point increase) (HR 1.19, 95% CI 1.02-1.39; P = 0.027), displaced fracture (HR 2.16, 95% CI 1.44-3.23; P < 0.001), unacceptable quality of implant placement (HR 2.70, 95% CI 1.59-4.55; P < 0.001), and smokers treated with cancellous screws versus smokers treated with a sliding hip screw (HR 2.94, 95% CI 1.35-6.25; P = 0.006). Additionally, for every 10-year decrease in age, participants experienced an average increased risk of 39% for hardware removal. Results of this study may inform future research by identifying high-risk patients who may be better treated with arthroplasty and may benefit from adjuncts to care (HR 1.39, 95% CI 1.05-1.85; P = 0.020). Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
NASA Astrophysics Data System (ADS)
Zhang, X.; Kopf, S.; Lee, A. C.
2016-12-01
The N stable isotope composition (δ15N) of biomass provides a powerful tool for reconstructing present and past N cycling, but its interpretation hinges on a complete understanding of the isotopic signature of biological nitrogen fixation, which sets the δ15N of newly fixed N. All biological nitrogen fixation is catalyzed by the metalloenzyme nitrogenase in a complex reaction that reduces inert atmospheric N2 gas into bioavailable ammonium. Recent investigations into the metal cofactor variants of nitrogenase revealed that the canonical Mo-, and alternative V-, and Fe-only isoforms of nitrogenase impart different isotope fractionations during N2 fixation in vivo, challenging the traditional view that N2 fixation only imparts small, invariable isotope effects of 0-2‰. However, the mechanistic basis for the fractionation of N2 fixation remains largely unknown. To better understand mechanisms underlying fractionation, we varied Fe availability and measured in vivo fractionations for the aerobic chemoheterotroph Azotobacter vinelandii utilizing Mo- or V-nitrogenase under batch culture conditions. Under all iron conditions, N2 fixation based on Mo-nitrogenase yielded lower fractionations (heavier biomasss δ15N) compared to V-nitrogenase. For fractionations associated with a single metalloenzyme, higher Fe concentrations, which correlated with faster growth rates, yielded small but systematically larger fractionations ( 1 ‰ increase for Mo- and V- nitrogenases). To directly determine the effect of growth rate on fractionation, we grew Mo-nitrogenase expressing A. vinelandii in Fe-replete medium at different growth rates using chemostats and found that growth rate alone does not alter fractionation. The results indicate that Fe availability, in addition to the type of nitrogenase metalloenzyme, controls 15N fractionation during N2 fixation by A. vinelandii.
Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah
2012-01-01
The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability.
Arnold, Heino; Stukenborg-Colsman, Christina; Hurschler, Christof; Seehaus, Frank; Bobrowitsch, Evgenij; Waizy, Hazibullah
2012-01-01
Introduction: The aim of this study was to examine resistance to angulation and displacement of the internal fixation of a proximal first metatarsal lateral displacement osteotomy, using a locking plate system compared with a conventional crossed screw fixation. Materials and Methodology: Seven anatomical human specimens were tested. Each specimen was tested with a locking screw plate as well as a crossed cancellous srew fixation. The statistical analysis was performed by the Friedman test. The level of significance was p = 0.05. Results: We found larger stability about all three axes of movement analyzed for the PLATE than the crossed screws osteosynthesis (CSO). The Friedman test showed statistical significance at a level of p = 0.05 for all groups and both translational and rotational movements. Conclusion: The results of our study confirm that the fixation of the lateral proximal first metatarsal displacement osteotomy with a locking plate fixation is a technically simple procedure of superior stability. PMID:22675409
Fixation orientation in ankle fractures with syndesmosis injury.
Nimick, Craig J; Collman, David R; Lagaay, Pieter
2013-01-01
Accurate reduction of the syndesmosis has been shown to be an important prognostic factor for functional outcome in ankle injuries that disrupt the syndesmosis. The purpose of the present case series was to assess the fixation orientation and the position of the fibula within the tibial incisura after open reduction and internal fixation of ankle fractures with syndesmosis injury. Computed tomography was used to assess the accuracy of the reduction. Twelve patients were included in the present case series. A ratio representing the relationship between the tibia and fibula and the orientation of the syndesmotic fixation was measured preoperatively and postoperatively and compared with the uninjured contralateral ankle, representing the patient's normal anatomy. The measurements were accomplished electronically to one tenth of 1 mm using Stentor Intelligent Informatics, I-site, version 3.3.1 (Phillips Electronics; Andover, MA). Posteriorly oriented syndesmotic fixation caused posterior translation of the fibula with respect to the tibia and anteriorly oriented syndesmotic fixation caused anterior translation. Copyright © 2013. Published by Elsevier Inc.
External fixators in the treatment of midshaft clavicle non-unions: a systematic review.
Barlow, Tim; Upadhyay, Piyush; Barlow, David
2014-02-01
Non- or mal-union of the clavicle is reported to occur in up to 15 % of conservatively treated fractures: the purpose of this systematic review is to examine the evidence for the use of external fixation in the treatment of clavicular non-union. We performed a search of MEDLINE and Embase, including all papers using external fixators for the treatment of clavicular non-union. Four papers satisfied our eligibility criteria: three case series and one case-control study. Level of evidence and quality assessment scoring were performed using published methods. Due to the heterogeneity of the study populations and interventions, no attempt at meta-analysis was made. External fixation in hypertrophic non-union of the clavicle, but not atrophic non-union, appears to be a reasonable treatment option. A pragmatic, multicentre, randomised controlled trial comparing external fixation and open reduction internal fixation in the treatment of hypertrophic non-union of the clavicle would be valuable.
7-year follow-up after open reduction and internal screw fixation in Bennett fractures.
Leclère, Franck Marie Patrick; Jenzer, Achat; Hüsler, Rolf; Kiermeir, David; Bignion, Dietmar; Unglaub, Frank; Vögelin, Esther
2012-07-01
Bennett fractures are unstable, and, with inadequate treatment, lead to osteoarthritis, weakness and loss of function of the first carpometacarpal joint. This study focuses on long-term functional and radiological outcomes after open reduction and internal fixation. Between June 1997 and December 2005, 24 patients with Bennett fractures were treated with open reduction and internal fixation with screws at our center. Radiological and functional assessments including range of motion of the thumb and pinch and grip strength were performed 4 months post-procedure and at the long-term follow-up, on average 83 months after surgery. Reduction of the Bennett fracture was maintained as it was at the time of the procedure in 96 % of the cases when fixation with two lag screws was performed. At the 4-month follow-up, mean pinch and grip strength reached 92 ± 3 and 89 ± 4 % of the contralateral side, respectively. Long-term follow-up demonstrated no correlation between the accuracy of the fracture reduction and the development of post-traumatic arthritis. Good clinical results could be observed, if successful reduction of the fracture was achieved and maintained. However, there was no correlation between the accuracy of the fracture reduction considering a gap and step <2 mm and the development of arthritis.
Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M
2018-03-01
Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.
Angular Stable Miniplate Fixation of Chronic Unstable Scaphoid Nonunion.
Schormans, Philip M J; Brink, Peter R G; Poeze, Martijn; Hannemann, Pascal F W
2018-02-01
Background Around 5 to 15% of all scaphoid fractures result in nonunion. Treatment of long-lasting scaphoid nonunion remains a challenge for the treating surgeon. Healing of scaphoid nonunion is essential for prevention of scaphoid nonunion advanced collapse and the subsequent predictable pattern of radiocarpal osteoarthritis. Purpose The purpose of this study was to investigate the feasibility of fixation of the scaphoid nonunion with a volar angular stable miniplate and cancellous bone grafting. We hypothesized that this technique could be successful, even in patients with previous surgery for nonunion and in patients with a long duration of nonunion. Patients and Methods A total of 21 patients enrolled in a single-center prospective cohort study. Healing of nonunion was assessed on multiplanar computed tomography scan of the wrist at a 3-month interval. Functional outcome was assessed by measuring grip strength, range of motion, and by means of the patient-rated wrist and hand evaluation (PRWHE) questionnaire. Results During follow-up, 19 out of 21 patients (90%) showed radiological healing of the nonunion. The range of motion did not improve significantly. Postoperative PRWHE scores decreased by 34 points. Healing occurred regardless of the length of time of the nonunion (range: 6-183 months) and regardless of previous surgery (38% of patients). Conclusion Volar angular stable miniplate fixation with autologous cancellous bone grafting is a successful technique for the treatment of chronic unstable scaphoid nonunion, even in patients with long-lasting nonunion and in patients who underwent previous surgery for a scaphoid fracture. Rotational interfragmentary stability might be an important determining factor for the successful treatment of unstable scaphoid nonunion. Level of Evidence Level IV.
Wang, Lei; Wu, Xiaobo; Qi, Wei; Wang, Yongbin; He, Quanjie; Xu, Fengsong; Liu, Hongyang
2015-10-01
To compare the biomechanical difference of 4 kinds of internal fixations for acetabular fracture in quadrilateral area. The transverse fracture models were created in 16 hemipelves specimens from 8 adult males, and were randomly divided into 4 groups according to different internal fixation methods (n = 4): infrapectineal buttress reconstruction plate (group A), infrapectineal buttress locking reconstruction plate (group B), reconstruction plate combined with trans-plate quadrilateral screws (group C), and anterior reconstruction plate-lag screw (group D). Then the horizontal displacement, longitudinal displacement of fractures, and axial stiffness were measured and counted to compare the stability after continuous vertical loading. Under the same loading, the horizontal and longitudinal displacements of groups A, B, C, and D were decreased gradually; when the loading reached 1 800 N, the longitudinal displacement of group A was more than 3.00 mm, indicating the failure criterion, while the axial stiffness increased gradually. Under 200 N loading, there was no significant difference (P > 0.05) in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups. When the loading reached 600-1 800 N, significant differences were found in horizontal displacement, longitudinal displacement, and axial stiffness among 4 groups (P < 0.05) except the horizontal displacement between groups C and D (P > 0.05). For acetabular fracture in the quadrilateral area, anterior reconstruction plate-lag screw for internal fixation has highest stability, followed by reconstruction plate combined with trans-plate quadrilateral screws, and they are better than infrapectineal buttress reconstruction plate and infrapectineal buttress locking reconstruction plate.
Tu, Shu-Qiang; Huang, Ke-Di; Shuai, Yong-Ming; Xu, Nan-Yun; Yuan, Qiu-Wen; Guo, Jian
2012-06-01
To study the curative effects of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture. From May 2006 to October 2009,32 patients (35 feet) with linguiform calcaneus fracture were treated by close nail-pry reduction and internal fixation with hollow screws, including 23 males and 9 females ranging in age from 25 to 46 years, with a mean of 37.6 years. According to Paley classification, 3 cases were Paley II a, and 29 cases were Paley II b. All cases were close fractures. The time from injury to operation was 3 to 10 days after most swelling subsided. Böhler angle and Gissane angle were measured by X-ray before and after operation. The therapeutic effect was assessed according to ZHANG Tie-liang's foot score. All the patients were followed-up for 6 to 18 months, with a mean of 12 months. All fractures gained bone healing. The time of fracture healing averaged 12 months. The fractures healed completely and no infection occurred. According to ZHANG Tie-liang's foot scale, the postoperative function was excellent in 18 feet, good in 10 feet, moderate in 5 feet and poor in 2 feet. The Böhler angle and Gissane angle were significant improved after treatment (P < 0.01). The surgical method of close nail-pry reduction and internal fixation with hollow screws for treatment of linguiform calcaneus fracture can regain the foot function, with minimal injury, fewer complications, earlier recovery and lower costs.
Injectable suture device for intraocular lens fixation.
Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L
2015-12-01
We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Biomechanical evaluation of bone screw fixation with a novel bone cement.
Juvonen, Tiina; Nuutinen, Juha-Pekka; Koistinen, Arto P; Kröger, Heikki; Lappalainen, Reijo
2015-07-30
Bone cement augmentation is commonly used to improve the fixation stability of orthopaedic implants in osteoporotic bone. The aim of this study was to evaluate the effect of novel bone cements on the stability of bone screw fixation by biomechanical testing and to compare them with a conventional Simplex(®)P bone cement and requirements of the standards. Basic biomechanical properties were compared with standard tests. Adhesion of bone cements were tested with polished, glass blasted and corundum blasted stainless steel surfaces. Screw pullout testing with/without cement was carried out using a synthetic bone model and cancellous and cortical bone screws. All the tested bone cements fulfilled the requirements of the standard for biomechanical properties and improved the screw fixation stability. Even a threefold increase in shear and tensile strength was achieved with increasing surface roughness. The augmentation improved the screw pullout force compared to fixation without augmentation, 1.2-5.7 times depending on the cement and the screw type. The good biomechanical properties of novel bone cement for osteoporotic bone were confirmed by experimental testing. Medium viscosity of the bone cements allowed easy handling and well-controlled penetration of bone cement into osteoporotic bone. By proper parameters and procedures it is possible to achieve biomechanically stable fixation in osteoporotic bone. Based on this study, novel biostable bone cements are very potential biomaterials to enhance bone screw fixation in osteoporotic bone. Novel bone cement is easy to use without hand mixing using a dual syringe and thus makes it possibility to use it as required during the operation.
Fuglesang, H F S; Flugsrud, G B; Randsborg, P H; Oord, P; Benth, J Š; Utvåg, S E
2017-08-01
This is a prospective randomised controlled trial comparing the functional outcomes of plate fixation and elastic stable intramedullary nailing (ESIN) of completely displaced mid-shaft fractures of the clavicle in the active adult population. We prospectively recruited 123 patients and randomised them to either plate fixation or ESIN. Patients completed the Quick Disabilities of the Arm, Shoulder and Hand (DASH) score at one to six weeks post-operatively. They were followed up at six weeks, three and six months and one year with radiographs, and their clinical outcome was assessed using both the DASH and the Constant Score. Plate fixation provided a faster functional recovery during the first six months compared with ESIN, but there was no difference after one year. The duration of surgery was shorter for ESIN (mean 53.4 minutes, 22 to 120) than for plate fixation (mean 69.7 minutes, 35 to 106, p < 0.001). The recovery after ESIN was slower with increasing fracture comminution and with open reduction (p < 0.05). Both methods return the patients to their pre-injury functional levels, but plate fixation has a faster recovery period in comminuted fractures than ESIN. ESIN has a shorter operative time and lower infection and implant rates of failure when using 2.5 mm nails or wider, suggesting that this is the preferred method in mid-shaft fractures with no comminution, whereas plate fixation is the superior method in comminuted fractures. Cite this article: Bone Joint J 2017;99-B:1095-1101. ©2017 The British Editorial Society of Bone & Joint Surgery.
Liu, Zhao-Jie; Jia, Jian; Zhang, Yin-Guang; Tian, Wei; Jin, Xin; Hu, Yong-Cheng
2017-05-01
The purpose of this article is to evaluate the efficacy and feasibility of preoperative surgery with 3D printing-assisted internal fixation of complicated acetabular fractures. A retrospective case review was performed for the above surgical procedure. A 23-year-old man was confirmed by radiological examination to have fractures of multiple ribs, with hemopneumothorax and communicated fractures of the left acetabulum. According to the Letounel and Judet classification, T-shaped fracture involving posterior wall was diagnosed. A 3D printing pelvic model was established using CT digital imaging and communications in medicine (DICOM) data preoperatively, with which surgical procedures were simulated in preoperative surgery to confirm the sequence of the reduction and fixation as well as the position and length of the implants. Open reduction with internal fixation (ORIF) of the acetabular fracture using modified ilioinguinal and Kocher-Langenbeck approaches was performed 25 days after injury. Plates that had been pre-bent in the preoperative surgery were positioned and screws were tightened in the directions determined in the preoperative planning following satisfactory reduction. The duration of the operation was 170 min and blood loss was 900 mL. Postoperative X-rays showed that anatomical reduction of the acetabulum was achieved and the hip joint was congruous. The position and length of the implants were not different when compared with those in preoperative surgery on 3D printing models. We believe that preoperative surgery using 3D printing models is beneficial for confirming the reduction and fixation sequence, determining the reduction quality, shortening the operative time, minimizing preoperative difficulties, and predicting the prognosis for complicated fractures of acetabulam. © 2017 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Riedl, Markus; Glisson, Richard R; Matsumoto, Takumi; Hofstaetter, Stefan G; Easley, Mark E
2017-06-01
Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion. Copyright © 2017. Published by Elsevier Ltd.
Zhang, Shao-Bo; Zhang, Yi-Bao; Wang, Sheng-Hong; Zhang, Hua; Liu, Peng; Zhang, Wei; Ma, Jing-Lin; Wang, Jing
2017-04-01
To compare the clinical efficacy and complications of limited internal fixation combined with external fixation (LIFEF) and open reduction and internal fixation (ORIF) in the treatment of Pilon fracture. We searched databases including Pubmed, Embase, Web of science, Cochrane Library and China Biology Medicine disc for the studies comparing clinical efficacy and complications of LIFEF and ORIF in the treatment of Pilon fracture. The clinical efficacy was evaluated by the rate of nonunion, malunion/delayed union and the excellent/good rate assessed by Mazur ankle score. The complications including infections and arthritis symptoms after surgery were also investigated. Nine trials including 498 pilon fractures of 494 patients were identified. The meta-analysis found no significant differences in nonunion rate (RR = 1.60, 95% CI: 0.66 to 3.86, p = 0.30), and the excellent/good rate (RR = 0.95, 95% CI: 0.86 to 1.04, p = 0.28) between LIFEF group and ORIF group. For assessment of infections, there were significant differences in the rate of deep infection (RR = 2.18, 95% CI: 1.34 to 3.55, p = 0.002), and the rate of arthritis (RR = 1.26, 95% CI: 1.03 to 1.53, p = 0.02) between LIFEF group and ORIF group. LIFEF has similar effect as ORIF in the treatment of pilon fractures, however, LIFEF group has significantly higher risk of complications than ORIF group does. So LIFEF is not recommended in the treatment of pilon fracture. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.
Park, Kyung-Soon; Lee, Keun-Bae; Na, Bo-Ram; Yoon, Taek-Rim
2015-07-01
In this work, we present relatively long-term results of femoral head fractures with a specific focus on Pipkin type I fractures. Fifty-nine femoral head fractures were treated according to modified Pipkin's classification as follows: type I, small fragment distal to the fovea centralis (FC); type II, large fragment distal to the FC; type III, large fragment proximal to the FC; type IV, comminuted fracture. There were 15 cases of type I, 28 of type II, 9 of type III, and 7 of type IV fractures. Conservative treatment with skeletal traction was performed in 4 type II cases, excision of the fragment in 15 type I and 10 type II cases, fixation of the fragment in 14 type II and all 9 type III cases, and total hip replacement in all 7 type IV cases. The overall clinical and radiographic outcomes were evaluated using previously published criteria, focusing on the results in Pipkin type I fractures with relatively large fragments. Based on Epstein criteria, in type II fractures, excellent or good clinical results were seen in 6 of 10 patients (60.0 %) treated by excision of the fragment and 12 of 14 patients (85.7 %) treated by internal fixation (p = 0.05). Also, excellent or good radiologic results were seen in 4 of 10 (40.0 %) patients treated by excision of the fragment and 12 of 14 (85.7 %) patients treated by internal fixation (p = 0.03). Even in Pipkin type I fractures, if the fragment is large (modified Pipkin type II), early reduction and internal fixation can produce good results.
Outcome of locking compression plates in humeral shaft nonunions
Kumar, Malhar N; Ravindranath, V Pratap; Ravishankar, MR
2013-01-01
Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used. Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system. Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient. Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands. PMID:23682176
Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo
2017-08-01
To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P <0.05), and the average stress and peak stress were significantly lower than in other 3 groups ( P <0.05). The acetabular weight-bearing area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P <0.05). There was no significant difference in the above indexes between group B and group C ( P >0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.
Outcome of Surgical Fixation of Lateral Column Distal Humerus Fractures.
Von Keudell, Arvind; Kachooei, Amir R; Moradi, Ali; Jupiter, Jesse B
2016-05-01
The purpose of this study was to report the long-term outcome and complications of surgically fixated lateral unicondylar distal humerus fractures. Retrospective Review. Two level 1 Trauma Centers, Massachusetts General Hospital and Brigham and Women's Hospital. Between 2002 and 2014, 24 patients treated with open reduction and internal fixation for lateral unicondylar distal humerus fractures (OTA/AO type B1 fractures) were retrospectively reviewed. Open reduction and internal fixation. Union rates, early complications, functional outcome, and the range of elbow motion were evaluated. Disabilities of the arm, shoulder, and hand, Mayo elbow Performance Index, satisfaction, pain scale, and American Shoulder and Elbow Surgeons. The mean age of patients was 46 ± 23 years at the time of surgery. The average final flexion/extension arc of motion was 108°. Reoperations were performed in 9 of 24 elbows after an average 21 ± 31 months. Twenty of the 24 patients were available for the clinical follow-up at an average of 70 months (range: 16-144 months). Disabilities of the arm, shoulder, and hand averaged at 10.8 ± 11.7 points, satisfaction at 9.5 ± 1.2, American Shoulder and Elbow Surgeons score at 88.5 ± 13.3 points at final follow-up. Based on the functional classification proposed by Jupiter, 16 demonstrated good to excellent results, 2 fair and 2 poor result. Outcome of open reduction and internal fixation of isolated lateral column distal humerus fractures can result in high union rates with acceptable outcome scores and high patient satisfaction despite a high reoperation rate. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
NASA Astrophysics Data System (ADS)
Mompeán, Carmen; Bode, Antonio; Gier, Elizabeth; McCarthy, Matthew D.
2016-08-01
A comparative analysis of natural abundance of stable N isotopes (δ15N) in individual amino acids and bulk organic matter of size-fractionated plankton revealed the differential impact of nitrogen fixation through the food web in a transect across the subtropical North Atlantic. All δ15N measurements showed low values in the central region, followed by the western zone, while maximum δ15N values were found in the eastern zone. These results were consistent with the prevalence of nitrogen fixation in the central and western zones, and the influence of the west Africa upwelling in the eastern zone. Use of compound-specific amino acid isotope data (CSI-AA) revealed relatively low variability in the impact of diazotrophic nitrogen within the different plankton size fractions, while δ15N of bulk organic matter showed high variability with size. Explicit CSI-AA trophic position estimates showed a small increase with mean plankton size class and varied in a relatively narrow range 1.8-2.5), with the lowest values in the central zone. High correlations between bulk plankton δ15N and individual amino acids (in particular Phe and Thr), as well as reconstructed total protein δ15N values, suggest a set of new relationships that may be important to tracing direct plankton contributions to nitrogen recycling in the ocean, including detrital organic nitrogen pools. Overall, these new results represent the most detailed investigation of CSI-AA data in plankton size classes to date, and indicated a greater importance of diazotrophic N than suggested by concurrent measurements of bulk δ15N, abundance of large nitrogen fixing organisms or nitrogen fixation rates.
Wilson, David J; Scully, William F; Min, Kyong S; Harmon, Tess A; Eichinger, Josef K; Arrington, Edward D
2016-06-01
Middle-third clavicle fractures represent 2% to 4% of all skeletal trauma in the United States. Treatment options include intramedullary (IM) as well as plate and screw (PS) constructs. The purpose of this study was to analyze the biomechanical stability of a specific IM system compared with nonlocking PS fixation under low-threshold physiologic load. Twenty fourth-generation Sawbones (Pacific Research Laboratories, Vashon, WA, USA) with a simulated middle-third fracture pattern were repaired with either an IM device (n = 10) or superiorly positioned nonlocking PS construct (n = 10). Loads were modeled to simulate physiologic load. Combined axial compression and torsion forces were sequentially increased until failure. Data were analyzed on the basis of loss of rotational stability using 3 criteria: early (10°), clinical (30°), and terminal (120°). No significant difference was noted between constructs in early loss of rotational stability (P > .05). The PS group was significantly more rotationally stable than the IM group on the basis of clinical and terminal criteria (P < .05 for both). All test constructs failed in rotational stability. When tested under physiologic load, fixation failure occurred from loss of rotational stability. No statistical difference was seen between groups under early physiologic loads. However, during load to failure, the PS group was statistically more rotationally stable than the IM group. Given the clavicle's function as a bony strut for the upper extremity and the biomechanical results demonstrated, rotational stability should be carefully considered during surgical planning and postoperative advancement of activity in patients undergoing operative fixation of middle-third clavicle fractures. Basic Science Study; Biomechanics. Published by Elsevier Inc.
The societal costs of femoral neck fracture patients treated with internal fixation.
Zielinski, S M; Bouwmans, C A M; Heetveld, M J; Bhandari, M; Patka, P; Van Lieshout, E M M
2014-03-01
The study rationale was to provide a detailed overview of the costs for femoral neck fracture treatment with internal fixation in the Netherlands. Mean total costs per patient at 2-years follow-up were
[Surgical approach of internal fixation of maxillofacial fracture].
Liu, Dashun; Zhang, Ruizhen; Dong, Xiao
2013-11-01
By summary and analysis of rigid internal fixation for the treatment of maxillofacial fractures incision and exposure, investigate the plate reasonable surgical approach of fracture reduction and fixation titanium. Summary of the 76 surgical cases, Counting the statistics of the number that the surgery ways choose by facial incision and fractures location, analysis of the indications for surgery and the advantages and disadvantages of various surgical approaches. Followed up for more than six months, in order to observe the recovery of occlusal function and the facial cosmetic results. The upper jaw or cheek bone has the more possibility in facial fracture, which used of a small incision hidden under the lip gingival sulcus and lower eyelid. After six months, the facial wound healing recover in good occlusal with no obvious scarring. Reasonable choice of surgical incision can make the fracture site exposure and the facial aesthetic effect into account.
Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi
2017-01-01
Purpose Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Methods Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. Results A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. Conclusion The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery. PMID:28152039
Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.
Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi
2017-01-01
Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.
Intercondylar humerus fracture- parallel plating and its results.
Kumar, Sanjiv; Singh, Sudhir; Kumar, Dharmender; Kumar, Neeraj; Verma, Reetu
2015-01-01
Intercondylar fracture of humerus is one of the commonest fractures of young adult and counts for about 30% of all elbow fractures. The treatment of these fractures continues to present challenges despite advances in internal fixation. Although orthogonal plating use to provid adequate functional results in these fractures, parallel plating is said to be mechanically more stable construct thus allowing early mobilization and better range of motion. AIM of the study is to assess the clinical as well functional results of these fractures treated with parallel plating. Prospective study in a tertiary care hospital. A total of 23 fresh patients of intercondylar fracture of humerus from Jan 2013 to May 2014 were included in the study and were treated with parallel plating. These patients were followed at 3, 6, 12, 24 weeks and at 1year of follow up and assessed in terms of time for union, range of motion, MAYO score, DASH score and complication rate. At final follow up Mayo score was 96.32±04.96 from 5.00±01.26 and DASH SCORE was 31.42±2.04 which dropped from 150±05.34, Range of motion improved from 21.38±05.70 to 116.1±07.92 with 100% union rate and complications less than 19%. Parallel plating for intercondylar fracture of humerus is excellent method of fixation and results are similar to those treated with orthogonal plating.
Godoy, Heidi M; Micciche, Mark J
It has been proposed that patients with talocalcaneal and talonavicular coalitions have decreased ankle joint range of motion. It has also been reported that rotational forces regularly absorbed by the talocalcaneal joint are transferred to the ankle joint in patients with coalitions, increasing the stress on the ankle joint after trauma. To the best of our knowledge, only 1 reported study has detailed the increased stress placed on the ankle joint secondary to a coalition. We present a case study of a 53-year-old female who experienced a traumatic fall and subsequent right ankle fracture. Advanced imaging studies revealed a comminuted tibial pilon fracture and talocalcaneal and talonavicular joint coalitions. She underwent open reduction and internal fixation for treatment of the fracture, and the coalitions were not treated because they were asymptomatic. She was kept non-weightbearing for 6 weeks postoperatively and was returned to a regular sneaker at 10 weeks postoperatively. The postoperative films revealed stable intact fixation and pain-free gait with no increased restriction in her ankle joint range of motion. The hardware was removed at 13 months postoperatively. She had not experienced increased pain or arthritic changes at 15 months postoperatively. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Osteosynthesis of fractures of the femur with flexible metallic intramedullary nails.
Firica, A; Troianescu, O; Petre, M
1978-04-01
The authors discuss their use of Ender's method in the treatment of fractures of the femur. The diameter and length of the nails depends on the type of fracture. 1) Three nails of 4 mm diameter are introduced in parallel from the medial condyle in fractures of the femoral neck; 2) 5 mm nails are used, in similar fashion, for the fixation of intertrochanteric and subtrochanteric fractures; 3) 5 mm nails are used for diaphyseal, supracondylar and intercondylar fractures, introduced in crossed fashion ("Eiffel Tower" technique) from both medial and lateral condyles. This method of fixation has proved to be extremely stable. The operation itself is quick, with no blood loss or shock. The patient can resume partial weight bearing after a week in stabilised intertrochanteric and shaft fractures, after a month in less stable types, and after three to four months in fractures of the neck of the femur. This report is based on the first 250 cases treated by this method.
Rechargeable Al-CO2 Batteries for Reversible Utilization of CO2.
Ma, Wenqing; Liu, Xizheng; Li, Chao; Yin, Huiming; Xi, Wei; Liu, Ruirui; He, Guang; Zhao, Xian; Luo, Jun; Ding, Yi
2018-05-21
The excessive emission of CO 2 and the energy crisis are two major issues facing humanity. Thus, the electrochemical reduction of CO 2 and its utilization in metal-CO 2 batteries have attracted wide attention because the batteries can simultaneously accelerate CO 2 fixation/utilization and energy storage/release. Here, rechargeable Al-CO 2 batteries are proposed and realized, which use chemically stable Al as the anode. The batteries display small discharge/charge voltage gaps down to 0.091 V and high energy efficiencies up to 87.7%, indicating an efficient battery performance. Their chemical reaction mechanism to produce the performance is revealed to be 4Al + 9CO 2 ↔ 2Al 2 (CO 3 ) 3 + 3C, by which CO 2 is reversibly utilized. These batteries are envisaged to effectively and safely serve as a potential CO 2 fixation/utilization strategy with stable Al. © 2018 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Namib Desert primary productivity is driven by cryptic microbial community N-fixation.
Ramond, Jean-Baptiste; Woodborne, Stephan; Hall, Grant; Seely, Mary; Cowan, Don A
2018-05-02
Carbon exchange in drylands is typically low, but during significant rainfall events (wet anomalies) drylands act as a C sink. During these anomalies the limitation on C uptake switches from water to nitrogen. In the Namib Desert of southern Africa, the N inventory in soil organic matter available for mineralisation is insufficient to support the observed increase in primary productivity. The C4 grasses that flourish after rainfall events are not capable of N fixation, and so there is no clear mechanism for adequate N fixation in dryland ecosystems to support rapid C uptake. Here we demonstrate that N fixation by photoautotrophic hypolithic communities forms the basis for the N budget for plant productivity events in the Namib Desert. Stable N isotope (δ 15 N) values of Namib Desert hypolithic biomass, and surface and subsurface soils were measured over 3 years across dune and gravel plain biotopes. Hypoliths showed significantly higher biomass and lower δ 15 N values than soil organic matter. The δ 15 N values of hypoliths approach the theoretical values for nitrogen fixation. Our results are strongly indicative that hypolithic communities are the foundation of productivity after rain events in the Namib Desert and are likely to play similar roles in other arid environments.
Lee, Daniel J; Elfar, John C
2014-09-01
The optimal management of displaced dorsal radius fractures (DRFs) in older patients remains an issue of debate. Bridging external fixation is a well-accepted treatment modality for severely comminuted DRFs, while open reduction and internal fixation with locked volar plating has emerged as a promising alternative in recent years. The current body of randomized trials supports the trend toward locked volar plating, as it allows for quicker improvement in subjective and functional outcomes. There is no clear evidence to suggest that one technique carries significantly less complications than the other. Locked volar plating should be considered in patients for whom an accelerated functional recovery would be advantageous. Otherwise, both external fixation and locked volar plating provide good long-term clinical outcomes.
Ejaz, Ashir; Laursen, Anders C; Jakobsen, Thomas; Rasmussen, Sten; Nielsen, Poul Torben; Laursen, Mogens B
2015-12-01
We aimed to determine whether not using a tourniquet in cemented TKA would affect migration of the tibial component measured by radiosterometric analysis (RSA). Seventy patients were randomized into a tourniquet group and a non-tourniquet group and using model-based RSA, the migration of the tibial component was analyzed. Primary and secondary outcome measures were maximum total point motion (MTPM) and translations and rotations. Follow-up period was 2 years. The tibial component was well fixated in both groups and no significant difference in migration between the two groups was detected (P=0.632). Mean MTPM (SD) was 0.47 mm (0.16) in the tourniquet group and 0.45 mm (0.21) in the non-tourniquet group. Absence of tourniquet indicates that stable fixation of the tibial component can be achieved in cemented TKA. Copyright © 2015 Elsevier Inc. All rights reserved.
Management of tibial fractures using a circular external fixator in two calves.
Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra
2010-07-01
To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.
Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.
Vedrine, Bertrand
2017-04-01
Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.
Use of an elastic transarticular external fixator construct for immobilization of the elbow joint
Vedrine, Bertrand
2017-01-01
Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726
Pelvic crescent fractures: variations in injury mechanism and radiographic pattern.
Gehlert, Rick J; Xing, Zhiqing; DeCoster, Thomas A
2014-01-01
Pelvic crescent fracture, also known as sacroiliac fracture-dislocation, is traditionally considered as a lateral compression injury and a vertically stable injury. Thirty consecutive cases were analyzed and it was found that 63% of cases were caused by lateral compression (LC), 27% by anteroposterior compression (APC), and 10% by vertical shear (VS). APC and VS injuries cause significant displacement of the anterior iliac fragment, but 21% of LC injury cases showed minimal displacement and were treated successfully with nonoperative treatment. Different injury mechanisms also produce different types of pelvic instability. More important, different injury mechanisms produce distinct radiographic fracture patterns regarding the obliquity of the fracture line and fracture surface. These differences in the fracture pattern will influence the decision of internal fixation options. Therefore, treatment of pelvic crescent fractures should be based on individual analysis of injury mechanism and radiographic fracture pattern.
The Future of Biologic Coatings for Orthopaedic Implants
Goodman, Stuart B.; Yao, Zhenyu; Keeney, Michael; Yang, Fan
2013-01-01
Implants are widely used for othopaedic applications such as fixing fractures, repairing nonunions, obtaining a joint arthrodesis, total joint arthroplasty, spinal reconstruction, and soft tissue anchorage. Previously, orthopaedic implants were designed simply as mechanical devices; the biological aspects of the implant were a byproduct of stable internal/external fixation of the device to the surrounding bone or soft tissue. More recently, biologic coatings have been incorporated into orthopaedic implants in order to modulate the surrounding biological environment. This opinion article reviews current and potential future use of biologic coatings for orthopaedic implants to facilitate osseointegration and mitigate possible adverse tissue responses including the foreign body reaction and implant infection. While many of these coatings are still in the preclinical testing stage, bioengineers, material scientists and surgeons continue to explore surface coatings as a means of improving clinical outcome of patients undergoing orthopaedic surgery. PMID:23391496
Refractures of the paediatric forearm with the intramedullary nail in situ.
van Egmond, Pim W; van der Sluijs, Hans A; van Royen, Barend J; Saouti, Rachid
2013-09-24
Forearm fractures in children are common. When conservative treatment fails, internal fixation with Elastic Stable Intramedullary Nailing (ESIN) become the first choice in the operative treatment of diaphyseal forearm shaft fractures. Refractures with the intramedullary nail in situ are known to occur but formal guidelines to guide management in such fractures are lacking. We present a well-documented case of a radius midshaft refracture in a 12-year-old boy with the intramedullary nail in situ, managed by closed reduction. Literature is reviewed for this type of complication, the treatment of 30 similar cases is discussed and a treatment strategy is defined. The refracture of the paediatric forearm fracture with the intramedullary nail in situ is a rare, but probably under recognised complication which is observed in approximately 2.3% of the study population. Closed reduction may be considered in these cases.
Tong, Wenqing; Dong, Youhai; Wu, Junguo
2014-06-01
To investigate the effectiveness of the opposite Judet approach for internal fixation of scapula neck and body fractures with reconstruction plate. METHODS Between February 2008 and November 2012, 44 cases of scapula neck and body fractures were treated through the opposite Judet approach for internal fixation with reconstruction plate. There were 34 males and 10 females with a mean age of 31 years (range, 20-53 years). Fractures were caused by traffic accident in 30 cases, by falling from height in 10 cases, and by crashing of heavy object in 4 cases. Of 44 cases, 6 were classified as type II A, 14 as type II B, 4 as type II C, and 20 as type IV fractures according to Miller standard. The mean time between operation and trauma was 11 days (range, 5-20 days). The glenopolar angle and the glenoid bank angle were measured on the anterior scapula X-ray films. The shoulder functions were evaluated according to the Rowe's scoring system. RESULTS The mean operation time was 80 minutes (range, 60-110 minutes). The mean intraoperative blood loss was 200 mL (range, 100-400 mL). Superficial wound infection occurred in 2 cases at 5 days after operation, and was cured after change dressing without dysfunction. Primary healing of incision was obtained in the other cases. All cases were followed up 12-23 months (mean, 18.3 months). No nerve or blood vessel injury, breakage of internal fixation, fracture displacement, bone nonunion, or osteomyelitis occurred. The glenopolar angle and glenoid bank angle were significantly improved from (17.08 ± 3.28)° and (23.52 ± 4.35)° before operation to (36.24 ± 5.89)° and (9.27 ± 2.12)° at 6 months after operation respectively (t = 18.792, P = 0.001; t = 19.503, P = 0.001). According to Rowe's scoring system for evaluation of shoulder function, the results were excellent in 32 cases, good in 8 cases, and fair in 4 cases at 1 year after operation; the excellent and 6 months good rate was 90.9%. Opposite Judet approach for internal fixation of scapula neck and body fractures with reconstruction plate has the advantages of less rotator cuff injury, complete exposure of the scapula two column structure through the three gaps, and easy operation, and the satisfactory fracture reduction and rigid fixation can be obtained.
Oztürkmen, Yusuf; Caniklioğlu, Mustafa; Karamehmetoğlu, Mahmut; Sükür, Erhan
2010-01-01
We aimed to evaluate the clinical and radiological outcomes of open reduction and internal fixation augmented with calcium phosphate cement (CPC) in the treatment of depressed tibial plateau fractures. Twenty-eight knees of 28 patients [19 males and 9 females; mean age, 41.2 years (range 22-72 years)] who had open reduction and internal fixation combined with CPC augmentation were included in this study. Seventeen fractures were Schatzker type II, 5 were type III, 3 were type IV, 2 were type V, and 1 was type VI. CPC was used to fill the subchondral bone defects in all knees. Fixation of the fragments was done with screws in 3 knees (10%). Standard proximal tibial plates or buttress plates were used in 25 knees (90%) with an additional split fragment extending distally to achieve internal fixation. Full weight-bearing was allowed in 6.4 weeks (range 6-12 weeks) after surgery. Resorption of CPC granules was defined as the decrease in the size and density of grafting material on radiographs. Rasmussen's radiological and clinical scores were determined postoperatively. Functionality was assessed with Lysholm knee scoring system. Activity was graded with Tegner's activity scale. Union was achieved in all patients with a mean follow-up of 22.2 months (range 6-36 months). There were no intraoperative complications. At the latest follow-up radiographs, resorption of the graft was observed in 25 knees (89%). Rasmussen's radiologic score was excellent in 17 patients (61%), good in 9 patients (32%), and fair in 2 patients (7%). Rasmussen's clinical score was excellent in 9 patients (32%), good in 18 patients (64%), and fair in 1 patient (4%). According to the Lysholm knee score, functional results were excellent in 16 patients (57%), good in 8 patients (29%), and fair in 4 patients (14%). Twenty-two patients (78%) achieved the preoperative activity level after surgery, and there was no significant difference between the mean preoperative and postoperative Tegner scores (4.11±0.68 and 4.04±0.64, respectively, p=0.161). CPC is a safe biomaterial with many advantages in augmenting the open reduction and internal fixation of depressed tibial plateau fractures, including elimination of morbidity associated with bone graft harvesting, the unlimited supply of bone substitute, the optimum filling of irregular bone defects, and shortening of the postoperative full weight-bearing time.
Kortmann, H R; Wolter, D; Meinecke, F W; Eggers, C
1986-11-01
Sixty-five patients with cervical spine injuries and varied neurological deficits were treated operatively. Evaluation revealed an improvement in neurological findings dependent upon the promptness of anatomical reduction in patients with incomplete lesions. The more frequent neurological improvement seen with open reduction and internal fixation as compared with closed reduction was not statistically significant but was felt to justify the additional resources required for internal fixation. In complete lesions, there was no evidence that the time of anatomical reduction was related to improvement in neurological findings.
Wilson, A W; Ethunandan, M; Brennan, P A
2005-02-01
The morbidity that results from surgical approaches to the condylar neck, and the time-consuming nature of the operation inhibits many surgeons from using open reduction and internal fixation for the treatment of condylar fractures. The many approaches that have been described stand testimony to the disadvantages of the individual techniques. The most common problems are limited access and injury to the facial nerve. We describe the transmasseteric antero-parotid (TMAP) technique, which offers swift access to the condylar neck while substantially reducing the risk to the facial nerve and eliminating the complications associated with transparotid approaches.
Archdeacon, Michael T
2015-02-01
The ilioinguinal and anterior intrapelvic approaches to the acetabulum often involve different strategies for the treatment of acetabular fractures. The ilioinguinal approach allows access to the entire internal iliac fossa and pelvic brim, including indirect access to the quadrilateral surface. In contrast, the anterior intrapelvic approach allows access to the anterior elements from inside the pelvis with the surgeon standing opposite the fracture pathology. Therefore, the goal of this article is to clarify the advantages and disadvantages for each approach with respect to exposure, reduction, and fixation.
Krettek, Christian; El Naga, Ashraf
2017-10-01
Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.
Temporary and definitive external fixation of war injuries: use of a French dedicated fixator.
Mathieu, Laurent; Ouattara, Naklan; Poichotte, Antoine; Saint-Macari, Erwan; Barbier, Olivier; Rongiéras, Fréderic; Rigal, Sylvain
2014-08-01
External fixation is the recommended stabilization method for both open and closed fractures of long bones in forward surgical hospitals. Specific combat surgical tactics are best performed using dedicated external fixators. The Percy Fx (Biomet) fixator was developed for this reason by the French Army Medical Service, and has been used in various theatres of operations for more than ten years. The tactics of Percy Fx (Biomet) fixator use were analysed in two different situations: for the treatment of French soldiers wounded on several battlefields and then evacuated to France and for the management of local nationals in forward medical treatment facilities in Afghanistan and Chad. Overall 48 externals fixators were implanted on 37 French casualties; 28 frames were temporary and converted to definitive rigid frames or internal fixation after medical evacuation. The 77 Afghan patients totalled 85 external fixators, including 13 temporary frames applied in Forward Surgical Teams (FSTs) prior to their arrival at the Kabul combat support hospital. All of the 47 Chadian patients were treated in a FST with primary definitive frames because of delayed surgical management and absence of higher level of care in Chad. Temporary frames were mostly used for French soldiers to facilitate strategic air medical evacuation following trauma damage control orthopaedic principles. Definitive rigid frames permitted achieving treatment of all types of war extremity injuries, even in poor conditions.
Identification of an algal carbon fixation-enhancing factor extracted from Paramecium bursaria.
Kato, Yutaka; Imamura, Nobutaka
2011-01-01
The green ciliate Paramecium bursaria contains several hundred symbiotic Chlorella species. We previously reported that symbiotic algal carbon fixation is enhanced by P. bursaria extracts and that the enhancing factor is a heat-stable, low-molecular-weight, water-soluble compound. To identify the factor, further experiments were carried out. The enhancing activity remained even when organic compounds in the extract were completely combusted at 700 degrees C, suggesting that the factor is an inorganic substance. Measurement of the major cations, K+, Ca2+, and Mg2+, by an electrode and titration of the extract resulted in concentrations of 0.90 mM, 0.55 mM, and 0.21 mM, respectively. To evaluate the effect of these cations, a mixture of the cations at the measured concentrations was prepared, and symbiotic algal carbon fixation was measured in the solution. The results demonstrated that the fixation was enhanced to the same extent as with the P. bursaria extract, and thus this mixture of K+, Ca2+, and Mg2+ was concluded to be the carbon fixation-enhancing factor. There was no effect of the cation mixture on free-living C. vulgaris. Comparison of the cation concentrations of nonsymbiotic and symbiotic Paramecium extracts revealed that the concentrations of K+ and Mg2+ in nonsymbiotic Paramecium extracts were too low to enhance symbiotic algal carbon fixation, suggesting that symbiotic P. bursaria provide suitable cation conditions for photosynthesis to its symbiotic Chlorella.
The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review
Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke
2016-01-01
More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439
Assessment of carbon fibre composite fracture fixation plate using finite element analysis.
Saidpour, Seyed H
2006-07-01
In the internal fixation of fractured bone by means of bone-plates fastened to the bone on its tensile surface, an on-going concern has been the excessive stress shielding of the bone by the excessively-stiff stainless-steel plate. The compressive stress shielding at the fracture-interface immediately after fracture-fixation delays callus formation and bone healing. Likewise, the tensile stress shielding in the layer of bone underneath the plate can cause osteoporosis and decrease in tensile strength of this layer. In this study a novel forearm internal fracture fixation plate made from short carbon fibre reinforced plastic (CFRP) was used in an attempt to address the problem. Accordingly, it has been possible to analyse the stress distribution in the composite plates using finite-element modelling. A three-dimensional, quarter-symmetric finite element model was generated for the plate system. The stress state in the underlying bone was examined for several loading conditions. Based on the analytical results the composite plate system is likely to reduce stress-shielding effects at the fracture site when subjected to bending and torsional loads. The design of the plate was further optimised by reducing the width around the innermost holes.
ZHOU, WEI; KONG, WEIQING; ZHAO, BIZHEN; FU, YISHAN; ZHANG, TAO; XU, JIANGUANG
2013-01-01
The aim of this study was to investigate the method of posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid for the treatment of thoracolumbar fractures. The efficacy of the procedure was also measured. Between June 2005 and March 2011, posterior thoracolumbar vertebral pedicle screw reduction and fixation plus artificial bone implantation via the affected vertebral pedicle under navigational aid was used to treat 30 patients with thoracolumbar fractures, including 18 males and 12 females, ranging in age from 21 to 57 years. Compared with the values prior to surgery, intraspinal occupation, vertebral height ratio and Cobb angle at the follow-up were significantly improved. At the long-term follow-up, the postoperative Cobb angle loss was <1° and the anterior vertebral body height loss was <2 mm. Posterior thoracolumbar vertebral pedicle screw reduction and fixation combined with vertebral bone implantation via the affected vertebral body under navigational aid may increase the accuracy and safety of surgery, and it is an ideal method of internal implantation. Bone implantation via the affected vertebral body may increase vertebral stability. PMID:23935737
An integer programming model for distal humerus fracture fixation planning.
Maratt, Joseph D; Peaks, Ya-Sin A; Doro, Lisa Case; Karunakar, Madhav A; Hughes, Richard E
2008-05-01
To demonstrate the feasibility of an integer programming model to assist in pre-operative planning for open reduction and internal fixation of a distal humerus fracture. We describe an integer programming model based on the objective of maximizing the reward for screws placed while satisfying the requirements for sound internal fixation. The model maximizes the number of bicortical screws placed while avoiding screw collision and favoring screws of greater length that cross multiple fracture planes. The model was tested on three types of total articular fractures of the distal humerus. Solutions were generated using 5, 9, 21 and 33 possible screw orientations per hole. Solutions generated using 33 possible screw orientations per hole and five screw lengths resulted in the most clinically relevant fixation plan and required the calculation of 1,191,975 pairs of screws that resulted in collision. At this level of complexity, the pre-processor took 104 seconds to generate the constraints for the solver, and a solution was generated in under one minute in all three cases. Despite the large size of this problem, it can be solved in a reasonable amount of time, making use of the model practical in pre-surgical planning.
Stress Fractures of Tibia Treated with Ilizarov External Fixator.
Górski, Radosław; Żarek, Sławomir; Modzelewski, Piotr; Górski, Ryszard; Małdyk, Paweł
2016-08-30
Stress fractures are the result of cyclic loading of the bone, which gradually becomes damaged. Most often they are treated by rest or plaster cast and, in rare cases, by internal fixation. There is little published data on initial reposition followed by stabilization with the Ilizarov apparatus in such fractures. Six patients were treated with an external fixator according to the Ilizarov method for a stress fracture of the tibia between 2007 and 2015. Three patients were initially treated conservatively. Due to increasing tibial deformation, they were qualified for surgical treatment with external stabilization. In the other patients, surgery was the first-line treatment. All patients demonstrated risk factors for a stress fracture. After the surgery, they fully loaded the operated limb. No patient developed malunion, nonunion, infection or venous thrombosis. The average time from the first operation to the removal of the external fixator was 19 weeks. Radiographic and clinical outcomes were satisfactory in all patients. 1. The Ilizarov method allows for successful stabilization of stress fractures of the tibia. 2. It may be a good alternative to internal stabilization, especially in patients with multiple comorbidities which affect bone quality and may impair soft tissue healing.
Dawei, Tian; Na, Liu; Jun, Lei; Wei, Jin; Lin, Cai
2013-02-01
Although there were many different types of fixation techniques for sacroiliac dislocation fracture, the treat remained challenging in posterior pelvic ring injury. The purpose of this study was to evaluate the biomechanical effects of a novel fixation system we designed. 12 human cadavers (L3-pelvic-femora) were used to compare biomechanical stability after reconstruction on the same specimens in four conditions: (1) intact, (2) cable system, (3) plate-pedicle screw system, and (4) cable system and plate-pedicle screw combination system (combination system). Biomechanical testing was performed on a material testing machine for evaluating the stiffness of the pelvic fixation construct in compression and torsion. The cable system and plate-pedicle screw system alone may be insufficient to resist vertical shearing and rotational loads; however the combination system for unstable sacroiliac dislocation fractures provided significantly greater stability than single plate-pedicle or cable fixation system. The novel fixation system for unstable sacroiliac dislocation fractures produced sufficient stability in axial compression and axial rotation test in type C pelvic ring injuries. It may also offer a better solution for sacroiliac dislocation fractures. Copyright © 2012 Elsevier Ltd. All rights reserved.
Caron, M; Kron, E; Saltrick, K R
1999-04-01
The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.
Long-term results of various therapy concepts in severe pilon fractures.
Koulouvaris, Panagiotis; Stafylas, Kosmas; Mitsionis, Gregory; Vekris, Marios; Mavrodontidis, Alexandros; Xenakis, Theodore
2007-07-01
Intra-articular fractures of the tibia plafond are among the most challenging of orthopaedic problems. This is a retrospective case-control study of surgically treated pilon fractures which was undertaken to compare the internal fixation with the two external fixation methods. This is a case-control study of 55 patients with 55 pilon fractures. There were 36 type C and 19 type B. Of these fractures, 24 were open and 31 closed. Three surgical protocols were used. In 20 patients, Group A, a half pin external fixator with ankle spanning was performed. The mean age of patients was 42.0 years (22.0-74.0), SD 14.1 and the mean follow-up was 77.7 months (38.0-132.0), SD 25.4. In 22 patients, Group B, a single ankle sparring ring hybrid external fixator under a small arthrotomy was performed. The mean age of patients was 48.4 years (28.0-76.0), SD 12.4 and mean follow-up was 67.9 months (36.0-132.0), SD 27.8. In 13 patients, Group C, a two-staged internal fixation was performed. The mean age was 45.6 years (30.0-66.0), SD 9.7 and the mean follow-up was 78.6 months (55.0-132.0), SD 25.4. We addressed the dissimilarity of the type of fracture in each group performing supplementary stratified analyses within each fracture type group. Group A had union in 6.9 months, group B in 5.6 months and group C in 5.1 months; P = 0.009. Six patients (Group A), two (Group B), and one (Group C) had limitation of ankle motion; P = 0.47. One patient from group C developed infection and the plate was removed. Four patients (Group A), one (Group B), and one (Group C) have developed posttraumatic arthritis (loss of joint space and pain); P = 0.25. Seven patients from Group A have reduced their activities; P = 0.004. In stratified statistical analysis by type of fracture, the associations noted for both fracture groups combined were also noted separately within each fracture group. In this long term follow-up study, the two-staged internal fixation and the hybrid fixation with small arthrotomy were equally efficacious in achieving bone union. Patients in external fixation with the ankle spanning had a significantly higher rate of delayed union. Also more patients in this group have reduced their activities.
Han, Sangwon; Oh, Minyoung; Yoon, Seokho; Kim, Jinsoo; Kim, Ji-Wan; Chang, Jae-Suk; Ryu, Jin-Sook
2017-03-01
Avascular necrosis (AVN) of the femoral head is a major complication after internal fixation of a femoral neck fracture and determines the functional prognosis. We investigated postoperative bone single-photon emission computed tomography/computed tomography (SPECT/CT) for assessing the risk of femoral head AVN. We retrospectively reviewed 53 consecutive patients who underwent bone SPECT/CT within 2 weeks of internal fixation of a femoral neck fracture and follow-up serial hip radiographs over at least 12 months. Nine patients developed femoral head AVN. In 15 patients who showed normal uptake on immediate postoperative SPECT/CT, no AVN occurred, whereas 9 of 38 patients who showed cold defects of the femoral head later developed AVN. The negative predictive value of immediate postoperative SPECT/CT for AVN was 100 %, whereas the positive predictive value was 24 %. Among 38 patients with cold defects, 1 developed AVN 3 months postoperatively. A follow-up bone SPECT/CT was performed in the other 37 patients at 2-10 months postoperatively. The follow-up bone SPECT/CT revealed completely normalized femoral head uptake in 27, partially normalized uptake in 8, and persistent cold defects in 2 patients. AVN developed in 3.7 % (1/27), 62.5 % (5/8), and 100 % (2/2) of each group, respectively. According to the time point of imaging, radiotracer uptake patterns of the femoral head on postoperative bone SPECT/CT indicate the risk of AVN after internal fixation of femoral neck fractures differently. Postoperative bone SPECT/CT may help orthopedic surgeons determine the appropriate follow-up of these patients.
Implant Removal After Internal Fixation of a Femoral Neck Fracture: Effects on Physical Functioning.
Zielinski, Stephanie M; Heetveld, Martin J; Bhandari, Mohit; Patka, Peter; Van Lieshout, Esther M M
2015-09-01
The effect of implant removal after internal fixation of a femoral neck fracture on physical functioning was analyzed. Characteristics of patients who had their implant removed were studied, as it is currently unknown from which type of patients implants are removed and what effect removal has on function. Secondary cohort study alongside a randomized controlled trial. Multicenter study in 14 hospitals. Patients who had their implant removed after internal fixation of a femoral neck fracture are compared with patients who did not. Patient characteristics and quality of life (Short Form 12, Western Ontario McMaster Osteoarthritis Index) were compared. Matched pairs were selected based on patient/fracture characteristics and prefracture physical functioning. Of 162 patients, 37 (23%) had their implant removed. These patients were younger (median age: 67 vs. 72 years, P = 0.024) and more often independently ambulatory prefracture (100% vs. 84%, P = 0.008) than patients who did not. They more often had evident implant back-out on x-rays (54% vs. 34%, P = 0.035), possibly related to a higher rate of Pauwels 3 fractures (41% vs. 22%, P = 0.032). In time, quality of life improved more in implant removal patients [+2 vs. -4 points, Short Form 12 (physical component), P = 0.024; +9 vs. 0 points, Western Ontario McMaster Osteoarthritis Index, P = 0.019]. Implant removal after internal fixation of a femoral neck fracture positively influenced quality of life. Implant removal patients were younger and more often independently ambulatory prefracture, more often had a Pauwels 3 fracture, and an evident implant back-out. Implant removal should be considered liberally for these patients if pain persists or functional recovery is unsatisfactory. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Treatment of malreduced pilon fracture: A case report and the result in the long-term follow-up.
Balioğlu, Mehmet Bulent; Akman, Yunus Emre; Bahar, Hakan; Albayrak, Akif
2016-01-01
The risk for post-traumatic osteoarthritis (POA) following tibial plafond joint trauma has been reported to be as high as 70-75%. In the treatment of more severe joint pathologies, with incongruity and intra-articular defects, internal or external fixations techniques may be required. We report the orthopedic management of a pilon fracture in a 30-year-old male with malunion and implant failure after initial mal-reduction of the fracture 9-months earlier. Tricortical iliac crest autologous bone grafting (TCG) was used in combination with internal fixation to restore distal tibial articular. The procedure resulted in a pain free ankle, sufficient range of motion for function and patient satisfaction. Early surgical intervention and anatomical reduction with appropriate fixation are recommended for intra-articular tibial pilon fractures. Autogenous bone grafting is a reliable treatment option to augment structural stability, bone defects and bone-healing. Indications for bone grafting include delayed union or nonunion, malunion, arthrodesis, limb salvage, and reconstruction of bone voids or defects. The application of TCG in the management of a malreduced tibial plafond fracture has not been described before. We performed TCG with internal fixation in order to restore stability, congruency and alignment in a young patient in whom a biological restoration was feasible due to good bone quality. In suitable cases, TCG might provide an alternative to arthrodesis or arthroplasty. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Treatment of malreduced pilon fracture: A case report and the result in the long-term follow-up
Balioğlu, Mehmet Bulent; Akman, Yunus Emre; Bahar, Hakan; Albayrak, Akif
2015-01-01
Introduction The risk for post-traumatic osteoarthritis (POA) following tibial plafond joint trauma has been reported to be as high as 70–75%. In the treatment of more severe joint pathologies, with incongruity and intra-articular defects, internal or external fixations techniques may be required. Presentation of case We report the orthopedic management of a pilon fracture in a 30-year-old male with malunion and implant failure after initial mal-reduction of the fracture 9-months earlier. Tricortical iliac crest autologous bone grafting (TCG) was used in combination with internal fixation to restore distal tibial articular. The procedure resulted in a pain free ankle, sufficient range of motion for function and patient satisfaction. Discussion Early surgical intervention and anatomical reduction with appropriate fixation are recommended for intra-articular tibial pilon fractures. Autogenous bone grafting is a reliable treatment option to augment structural stability, bone defects and bone-healing. Indications for bone grafting include delayed union or nonunion, malunion, arthrodesis, limb salvage, and reconstruction of bone voids or defects. The application of TCG in the management of a malreduced tibial plafond fracture has not been described before. Conclusion We performed TCG with internal fixation in order to restore stability, congruency and alignment in a young patient in whom a biological restoration was feasible due to good bone quality. In suitable cases, TCG might provide an alternative to arthrodesis or arthroplasty. PMID:26724734
Pizanis, Antonius; Holstein, Jörg H; Vossen, Felix; Burkhardt, Markus; Pohlemann, Tim
2013-08-26
Anterior bone grafts are used as struts to reconstruct the anterior column of the spine in kyphosis or following injury. An incomplete fusion can lead to later correction losses and compromise further healing. Despite the different stabilizing techniques that have evolved, from posterior or anterior fixating implants to combined anterior/posterior instrumentation, graft pseudarthrosis rates remain an important concern. Furthermore, the need for additional anterior implant fixation is still controversial. In this bench-top study, we focused on the graft-bone interface under various conditions, using two simulated spinal injury models and common surgical fixation techniques to investigate the effect of implant-mediated compression and contact on the anterior graft. Calf spines were stabilised with posterior internal fixators. The wooden blocks as substitutes for strut grafts were impacted using a "pressfit" technique and pressure-sensitive films placed at the interface between the vertebral bone and the graft to record the compression force and the contact area with various stabilization techniques. Compression was achieved either with posterior internal fixator alone or with an additional anterior implant. The importance of concomitant ligament damage was also considered using two simulated injury models: pure compression Magerl/AO fracture type A or rotation/translation fracture type C models. In type A injury models, 1 mm-oversized grafts for impaction grafting provided good compression and fair contact areas that were both markedly increased by the use of additional compressing anterior rods or by shortening the posterior fixator construct. Anterior instrumentation by itself had similar effects. For type C injuries, dramatic differences were observed between the techniques, as there was a net decrease in compression and an inadequate contact on the graft occurred in this model. Under these circumstances, both compression and the contact area on graft could only be maintained at high levels with the use of additional anterior rods. Under experimental conditions, we observed that ligamentous injury following type C fracture has a negative influence on the compression and contact area of anterior interbody bone grafts when only an internal fixator is used for stabilization. Because of the loss of tension banding effects in type C injuries, an additional anterior compressing implant can be beneficial to restore both compression to and contact on the strut graft.
Luo, Huasong; Chen, Liaobin; Liu, Kebin; Peng, Songming; Zhang, Jien; Yi, Yang
2016-01-01
The aim of this study was to evaluate the clinical outcome of tibial pilon fractures treated with arthroscopy and assisted reduction with an external fixator. Thirteen patients with tibial pilon fractures underwent assisted reduction for limited lower internal fixation with an external fixator under arthroscopic guidance. The weight-bearing time was decided on the basis of repeat radiography of the tibia 3 months after surgery. Postoperative ankle function was evaluated according to the Mazur scoring system. Healing of fractures was achieved in all cases, with no complications such as severe infection, skin necrosis, or an exposed plate. There were 9 excellent, 2 good, and 2 poor outcomes, scored according to the Mazur system. The acceptance rate was 85%. Arthroscopy and external fixator-assisted reduction for the minimally invasive treatment of tibial pilon fractures not only produced less trauma but also protected the soft tissues and blood supply surrounding the fractures. External fixation could indirectly provide reduction and effective operative space for arthroscopic implantation, especially for AO type B fractures and partial AO type C1 fractures.
Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M
2017-12-01
In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial for stability.
Resch, H; Krappinger, D; Moroder, P; Auffarth, A; Blauth, M; Becker, J
2017-04-01
Fractures of the acetabulum in younger patients are commonly treated by open reduction and internal fixation. For elderly patients, stable primary total hip arthroplasty with the advantage of immediate postoperative mobilization might be the adequate treatment. For this purpose, a sufficiently stable fixation of the acetabular component is required. Between August 2009 and 2014, 30 cases were reported in which all patients underwent total hip arthroplasty additionally to a customized implant designed as an antiprotrusion cage. Inclusion criteria were an acetabular fracture with or without a previous hemiarthroplasty, age above 65 years, and pre-injury mobility dependent on a walking frame at the most. The median age was 79.9 years (65-92), and of 30 fractures, 25 were primary acetabular fractures (83%), four periprosthetic acetabular fractures (14%), and one non-union after a failed ORIF (3%). The average time from injury to surgery was 9.4 days (3-23) and 295 days for the non-union case. Mean time of surgery was 154.4 min (range 100 to 303). In 21 cases (70%), mobilization with full weight bearing was possible within the first 10 days. Six patients died before the follow-up examination 3 and 6 months after surgery, while 24 patients underwent radiologic examination showing consolidated fractures in bi-plane radiographs. In 9 patients, additional CT scan was performed which confirmed the radiographical results. 13 had regained their pre-injury level of mobility including the non-union case. Only one patient did not regain independent mobility. Four complications were recognized with necessary surgical revision (one prosthetic head dislocation, one pelvic cement leakage, one femoral shaft fracture, and one infected hematoma). The presented cage provides the possibility of early mobilization with full weight bearing which represents a valuable addition to the treatment spectrum in this challenging patient group.
Maloney, Karl
2015-09-01
In general, dentoalveolar fractures are a common injury seen in emergency departments, dental offices, and oral and maxillofacial surgery practices. These injuries can be the result of direct trauma or indirect trauma. Direct trauma more often causes trauma to the maxillary dentition due to the exposure of the maxillary anterior teeth. Indirect trauma is usually the result of forced occlusion secondary to a blow to the chin or from a whiplash injury. Falls are the most common mechanism of injury seen in the pediatric group. In adolescents, many of these fractures are sustained during sporting activities. However, the use of mouth guards and other protective equipment has decreased this number. Most adult injuries are caused by motor vehicle accidents, contact sports, falls, bicycles, interpersonal violence, medical/dental mishaps, and industrial accidents. Early intervention to reduce and stabilize the fracture is required to establish a bony union and ensure correct function. Most dentoalveolar fractures have bilateral stable adjacent dentition and are treated with a closed technique utilizing an acid-etch/resin splint followed by splint removal at 4 weeks. Other inferior stabilization treatments used are arch bars and other wiring techniques. It is widely accepted that semirigid stabilization techniques, such as an acid-etch/resin splint or wiring procedures, are adequate to treat dentoalveolar fractures. This is in contrast to the treatment of mandible fractures where AO principles of rigid fixation are often followed. Fractures that are unable to be reduced sometimes necessitate an open reduction followed by internal fixation, sometimes using a secondary splint for mobile teeth. In those rare cases when there are not stable adjacent teeth bilaterally other modalities must be considered. In the present report, two cases are presented where circummandibular wires were used to treat fractured mandibular dentoalveolar segments adjacent to edentulous areas.
The International Student Safety Debate: Moving beyond Denial
ERIC Educational Resources Information Center
Nyland, C.; Forbes-Mewett, H.; Marginson, S.
2010-01-01
In 2009 international student safety became an issue of immediate concern to Australian international education exporters following a series of demonstrations by Indian students and interventions by concerned foreign governments. With these developments the "industry" became fixated on how best to secure Australia's share of the…
A unique physeal injury of the distal phalanx.
Berber, Onur; Singh, Bijayendra
2015-01-01
An unusual Salter-Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation.
Choroidal Blood Flow Decreases with Age: An MRI Study
San Emeterio Nateras, Oscar; Harrison, Joseph M.; Muir, Eric R.; Zhang, Yi; Peng, Qi; Chalfin, Steven; Gutierrez, Juan E.; Johnson, Daniel A.; Kiel, Jeffrey W.; Duong, Timothy Q.
2014-01-01
Purpose To verify that a visual fixation protocol with cued eye blinks achieves sufficient stability for magnetic resonance imaging (MRI) blood-flow measurements and to determine if choroidal blood flow (ChBF) changes with age in humans. Methods The visual fixation stability achievable during an MRI scan was measured in five normal subjects using an eye-tracking camera outside the MRI scanner. Subjects were instructed to blink immediately after recorded MRI sound cues but to otherwise maintain stable visual fixation on a small target. Using this fixation protocol, ChBF was measured with MRI using a 3 Tesla clinical scanner in 17 normal subjects (24–68 years old). Arterial and intraocular pressures (IOP) were measured to calculate perfusion pressure in the same subjects. Results The mean temporal fluctuations (standard deviation) of the horizontal and vertical displacements were 29 ± 9 μm and 38 ± 11 μm within individual fixation periods, and 50 ± 34 μm and 48 ± 19 μm across different fixation periods. The absolute displacements were 67 ± 31 μm and 81 ± 26 μm. ChBF was negatively correlated with age (R =−0.7, p = 0.003), declining 2.7 ml/100 ml/min per year. There were no significant correlations between ChBF versus perfusion pressure, arterial pressure, or IOP. There were also no significant correlations between age versus perfusion pressure, arterial pressure, or IOP. Multiple regression analysis indicated that age was the only measured independent variable that was significantly correlated with ChBF (p = 0.03). Conclusions The visual fixation protocol with cued eye blinks was effective in achieving sufficient stability for MRI measurements. ChBF had a significant negative correlation with age. PMID:24655028
Immediate mobilization following fixation of mandible fractures: a prospective, randomized study.
Kaplan, B A; Hoard, M A; Park, S S
2001-09-01
To compare outcomes of open reduction and internal fixation of displaced mandible fractures followed by either immediate mobilization or 2 weeks of mandibular-maxillary fixation. A prospective, randomized, single-blinded study was performed. The study was performed between January 1, 1997, and March 30, 2000. Inclusion criteria were displaced fractures between the mandibular angles, age greater than 16 years, and no involvement of the alveolus, ramus, condyles, or maxilla. All fractures were repaired by means of open reduction and internal fixation using 2.0-mm titanium plates secured either in transoral fashion or percutaneously. Data were collected at 6-week and 3- and 6-month postoperative examinations. Variables were assessed by a surgeon blinded to the history of immobilization and included pain, malunion or nonunion, occlusion, trismus, wound status, infection rates, dental hygiene, and weight loss. Twenty-nine consecutive patients were enrolled, 16 patients to immediate function and 13 patients to 2 weeks of mandibular-maxillary fixation. No statistically significant differences were found between groups for any of the variables. Immediate release and temporary immobilization showed mean weight loss of 10 and 8 pounds and trismus of 4.2 and 4.6 cm, respectively. One wound separation and one infection were seen in the immobilization population, and no wound separation or infection was seen in the immediate-release group. Dental hygiene was similar between the groups. No malunion or nonunion was noted in either group. In this prospective and randomized study, no significant differences were noted between the groups receiving either immediate release or 2 weeks of mandibular-maxillary fixation. The findings support the treatment of selective mandible fractures with 2.0-mm miniplates and immediate mobilization.
Mao, Ke-ya; Wang, Yan; Xiao, Song-hua; Zhang, Yong-gang; Liu, Bao-wei; Wang, Zheng; Zhang, Xi-Feng; Cui, Geng; Zhang, Xue-song; Li, Peng; Mao, Ke-zheng
2013-08-01
To investigate the feasibility of minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) using hybrid internal fixation of pedicle screws and a translaminar facet screw for recurrent lumbar disc herniation. From January 2010 to December 2011, 16 recurrent lumbar disc herniation patients, 10 male and 6 female patients with an average age of 45 years (35-68 years) were treated with unilateral incision MIS-TLIF through working channel. After decompression, interbody fusion and fixation using unilateral pedicle screws, a translaminar facet screw was inserted from the same incision through spinous process and laminar to the other side facet joint. The results of perioperative parameters, radiographic images and clinical outcomes were assessed. The repeated measure analysis of variance was applied in the scores of visual analogue scale (VAS) and Oswestry disablity index (ODI). All patients MIS-TLIF were accomplished under working channel including decompression, interbody fusion and hybrid fixation without any neural complication. The average operative time was (148 ± 75) minutes, the average operative blood loss was (186 ± 226) ml, the average postoperative ambulation time was (32 ± 15) hours, and the average hospitalization time was (6 ± 4) days. The average length of incision was (29 ± 4) mm, and the average length of translaminar facets screw was (52 ± 6) mm. The mean follow-up was 16.5 months with a range of 12-24 months. The postoperative X-ray and CT images showed good position of the hybrid internal fixation, and all facets screws penetrate through facets joint. The significant improvement could be found in back pain VAS, leg pain VAS and ODI scores between preoperative 1 day and postoperative follow-up at all time-points (back pain VAS:F = 52.845, P = 0.000;leg pain VAS:F = 113.480, P = 0.000;ODI:F = 36.665, P = 0.000). Recurrent lumbar disc herniation could be treated with MIS-TLIF using hybrid fixation through unilateral incision, and the advantage including less invasion and quickly recovery.
Verhage, Samuel Marinus; Hoogendoorn, Jochem Maarten; Krijnen, Pieta; Schipper, Inger Birgitta
2018-05-12
Whether or not and how to fixate the posterior malleolus fracture seems to depend on the fracture fragment size and its amount of dislocation, but clear guidelines for daily practice are lacking. In this review, we summarize the literature on preferred treatment of the posterior fragment in trimalleolar fractures. A systematic review of publications between January 1995 and April 30 2017 on this topic in the PubMed, Embase, and Cochrane databases was performed according to the PRISMA statement. Seventeen (2 prospective and 15 retrospective) of the 180 identified studies were included. Six studies report on indications for fixation of posterior malleolus fracture fragments. Eleven studies compare different fixation approaches and techniques for the posterior fragment. Meta-analysis was not possible due to varying fixation criteria and outcomes. There was no clear association between posterior fragment size and functional outcome or development of osteoarthritis. The non-anatomical reduction of the fragment was of more influence on outcome. Radiological and functional outcome was better after open reduction and internal fixation via the posterolateral approach than after percutaneous anterior-to-posterior screw fixation. The posterior fragment size is not a clear indication for its fixation. A step-off, however, seems an important indicator for developing posttraumatic osteoarthritis and worse functional outcome. Posterior fragments involving the intra-articular surface need to be reduced and fixated to prevent postoperative persisting step-off. Furthermore, fixation of the posterior malleolus via an open posterolateral approach seems superior to percutaneous anterior-to-posterior fixation. However, these results need to be confirmed in a prospective comparative trial. Therapeutic level II.
Lisfranc injuries in children and adolescents.
Hill, Jaclyn F; Heyworth, Benton E; Lierhaus, Anneliese; Kocher, Mininder S; Mahan, Susan T
2017-03-01
In this descriptive analysis of pediatric Lisfranc injuries, records of 56 children treated for bony or ligamentous Lisfranc injuries over a 12-year period were reviewed. Overall, 51% of fractures and 82% of sprains were sports-related (P=0.03). A total of 34% of the cohort underwent open reduction internal fixation, which was more common among patients with closed physes (67%). Full weight bearing was allowed in open reduction internal fixation patients at a mean of 14.5 weeks, compared to 6.5 weeks in the nonoperative group. Complications were rare (4%) and included physeal arrest in one patient and a broken, retained implant in one patient.
PHYSICAL AND BIOLOGICAL PROPERTIES OF INFLUENZA VIRUS COMPONENTS OBTAINED AFTER ETHER TREATMENT
Davenport, Fred M.; Rott, Rudolf; Schäfer, Werner
1960-01-01
The Rostock strain of fowl plague, the swine, A, A', and Asian strains of influenza A as well as their hemagglutinin and internal s antigen subunits obtained after ether splitting, were found to be morphologically indistinguishable when examined simultaneously. Hemagglutinin fractions reacted in a highly strain specific manner when tested by hemagglutination inhibition or by complement fixation using sera obtained after infection. With the same sera internal s antigen fractions were shown to be serologically distinguishable by complement fixation. This observation may stimulate interest in the feasibility of employing immunologic techniques for the study of nucleoproteins. The significance of the findings reported is discussed. PMID:13719952
Femoral neck shortening after internal fixation of a femoral neck fracture.
Zielinski, Stephanie M; Keijsers, Noël L; Praet, Stephan F E; Heetveld, Martin J; Bhandari, Mohit; Wilssens, Jean Pierre; Patka, Peter; Van Lieshout, Esther M M
2013-07-01
This study assesses femoral neck shortening and its effect on gait pattern and muscle strength in patients with femoral neck fractures treated with internal fixation. Seventy-six patients from a multicenter randomized controlled trial participated. Patient characteristics and Short Form 12 and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were collected. Femoral neck shortening, gait parameters, and maximum isometric forces of the hip muscles were measured and differences between the fractured and contralateral leg were calculated. Variables of patients with little or no shortening, moderate shortening, and severe shortening were compared using univariate and multivariate analyses. Median femoral neck shortening was 1.1 cm. Subtle changes in gait pattern, reduced gait velocity, and reduced abductor muscle strength were observed. Age, weight, and Pauwels classification were risk factors for femoral neck shortening. Femoral neck shortening decreased gait velocity and seemed to impair gait symmetry and physical functioning. In conclusion, internal fixation of femoral neck fractures results in permanent physical limitations. The relatively young and healthy patients in our study seem capable of compensating. Attention should be paid to femoral neck shortening and proper correction with a heel lift, as inadequate correction may cause physical complaints and influence outcome. Copyright 2013, SLACK Incorporated.
2018-01-01
Objectives The goal of this study was to evaluate the rates of complications, morbidity, and safety with the transparotid approach. Materials and Methods A retrospective study was conducted and consisted of 53 surgically treated patients in the past five years for low condylar neck and subcondylar fractures. Only patients with malocclusion and who underwent open reduction with internal fixation with the retromandibular transparotid approach were included. The examined parameters were postoperative suboptimal occlusion, deflection, saliva fistula, and facial nerve weakness. Results Fifty-three patients had an open reduction with internal fixation on 55 sides (41 males, 77.4%; mean age, 42 years [range, 18–72 years]). Four patients (7.5%) experienced transient facial nerve weakness of the marginal mandibular branch, but none was permanent. Four patients had a salivary fistula, and 5 patients showed postoperative malocclusion, where one needed repeat surgery after one year. One patient showed long-term deflection. No other complications were observed. Conclusion The retromandibular transparotid approach is a safe procedure for open reduction and internal fixation of low condylar neck and subcondylar fractures, and it has minimal complications. PMID:29732312
Surgical repair of femoral fractures in New World camelids: five cases (1996-2003).
Shoemaker, R W; Wilson, D G
2007-04-01
Five New World camelids were admitted to the Western College of Veterinary Medicine between 1996 and 2003 for evaluation of femoral fractures. There were three alpacas and two llamas. Four of the animals were female and three were less than 3 months of age. Fracture configurations consisted of distal physeal fractures (three), a comminuted diaphyseal/metaphyseal fracture, and a transverse diaphyseal fracture. Fractures were diagnosed with a combination of physical examination and radiographs in all cases. All five fractures were repaired with internal fixation and three animals were discharged from the hospital with fractures that healed. One cria underwent successful internal fixation but died from pulmonary oedema during recovery from anaesthesia. Postoperative complications were rare and limited to inadequate fracture stability in one alpaca and prolonged recovery to weight bearing in another. One llama with a comminuted metaphyseal fracture, repaired with a 4.5 mm dynamic compression plate, subsequently had catastrophic failure of the bone 17 days after surgery. Overall the clients were pleased with the outcome of discharged animals. Although femoral fractures are considered rare, they pose a unique opportunity for the large animal veterinarian to successfully achieve fracture union with the aid of internal fixation.
Brasileiro, Bernardo Ferreira; Grotta-Grempel, Rafael; Ambrosano, Glaucia Maria Bovi; Passeri, Luis Augusto
2012-04-01
The aim of this study was to evaluate the biomechanical features of 3 different methods of rigid internal fixation for sagittal split ramus osteotomy for mandibular setback in vitro. Sixty polyurethane replicas of human hemimandibles were used as substrates, simulating a 5-mm setback surgery by sagittal split ramus osteotomy. These replicas served to reproduce 3 different techniques of fixation, including 1) a 4-hole plate and 4 monocortical screws (miniplate group), 2) a 4-hole plate and 4 monocortical screws with 1 additional bicortical positional screw (hybrid group), and 3) 3 bicortical positional screws in a traditional inverted-L pattern (inverted-L group). After fixation, hemimandibles were adapted to a test support and subjected to lateral torsional forces on the buccal molar surface and vertical cantilever loading on the incisal edge with an Instron 4411 mechanical testing unit. Peak loadings at 1, 3, 5, and 10 mm of displacement were recorded. Means and standard deviation were analyzed using analysis of variance and Tukey test with a 5% level of significance, and failures during tests were recorded. Regardless of the amount of displacement and direction of force, the miniplate group always showed the lowest load peak scores (P < .01) compared with the other fixation techniques. The hybrid group demonstrated behavior similar to the inverted-L group in lateral and vertical forces at any loading displacement (P > .05). Molar load tests required more force than incisal load tests to promote the same displacement in the mandibular setback model (P < .05). For mandibular setback surgery of 5 mm, this study concluded that the fixation technique based on the miniplate group was significantly less rigid than the fixation observed in the hybrid and inverted-L groups. Mechanically, adding 1 bicortical positional screw in the retromolar region in the miniplate technique may achieve the same stabilization offered by inverted-L fixation for mandibular sagittal split ramus osteotomy setback surgery in vitro. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Guan, Ting-Jin; Sun, Peng; Zheng, Liang-Guo; Qi, Xiang-Yang
2014-01-01
To study measurement methods of acromioclavicular and coracoclavicular ligament injuries,its therapeutic effects and complications during internal fixation operation for the treatment of fresh acromioclavicular joint dislocations of Tossy type III. From July 2003 to May 2012,127 patients with acromioclavicular joint dislocations of Tossy type III were treated with wire fixation from coracoid process to clavicle or hook-plate fixation. The patients were divided into group A (63 cases) and group B (64 cases) according to whether acromioclavicular ligament and coracoclavicular ligament were repaired or not. In group A (ligaments repaired), there were 39 males and 24 females with an average age of (33.25 +/- 8.46) years old (ranged from 17 to 59 years). And in group B (no ligaments repaired), there were 41 males and 23 females with an average age of (34.10 +/- 7.19) years (ranged from 19 to 57 years). The operation times, intraoperative blood loss, postoperative infections, internal fixation failure, recurrence and other complications, together with therapeutic effects were compared between two groups. The outcome was analyzed according to Karlsson standard. In group A, 54 patients got an excellent result and 9 good according to Karlsson standard;the average operative time was (55.90 +/- 26.56) min; the average intraoperative bleeding amount was (99.80 +/- 50.30) ml; 1 patient had wire broken without re-dislocation at 16 weeks after operation, 3 patients got wound fat liquefaction and recovered after treatment, 1 patient had pain after shoulder joint motion and pain disappeared after implants were taken out. In group B, 52 patients got an excellent result and 12 good according to Karlsson standard; the average operative time was (49.50 +/- 23.14) min; the average intraoperative bleeding amount was (87.30 +/- 46.41) ml; 2 patients got wound fat liquefaction, and 2 patients had pain after shoulder joint motion. All the patients were followed up, and the duration ranged from 9 to 16 months. All internal steel-wire or hook plate were taken out during 4 to 9 months without acromioclavicular joint re dislocation. There were no significant difference in the average operative time, the average intraoperative blood less, complication recurrence rates of fixation failure, wound fat liquefaction, postoperative infection, acromioclavicular joint re-dislocation, and therapeutic effects between two groups. Both wire and clavicular hook plate fixation, performed for fresh acromioclavicular joint dislocation with Tossy type III, are simple, effective, less invasive method with less blood loss. In addition, the treatment without ligaments repaired could not increase incidence of complications.
Souder, Christopher D; Bomar, James D; Wenger, Dennis R
2014-12-01
Slipped capital femoral epiphysis (SCFE) can be treated by a variety of methods with the traditional method of in situ pin fixation being most commonly used. More recently, the Modified Dunn (Mod. Dunn) procedure consisting of capital realignment has been popularized as a treatment method for SCFE, particularly for more severe cases. Over the last 5 years, our institution has selectively used this method for more complex cases. The purpose of this article is to evaluate the differences between these 2 treatment methods in terms of avascular necrosis (AVN) rate, reoperation rate, and complication rate. Eighty-eight hips that were surgically treated for SCFE between July 2004 and June 2012 met our inclusion criteria. The in situ fixation group included 71 hips, whereas 17 hips were anatomically reduced with the Mod. Dunn procedure. Loder classification, severity, acuity, complication rate, and reoperation rate were determined for the 2 cohorts. The χ analysis was performed to evaluate the relationship between the treatment method and outcome. As expected, stable slips did well with in situ pinning with no cases of AVN, even in more severe slips. Ten stable slips were treated with the Mod. Dunn approach and 2 (20%) developed AVN. Unstable slips were more difficult to treat with 3 of the 7 hips stabilized in situ developing AVN (43%). Two of the 7 unstable slips treated by the Mod. Dunn procedure developed AVN (29%). The other outcomes studied (reoperation rate and complication rate) were not significantly related to the surgical treatment method (P = 0.732 and 0.261, respectively). In situ pinning remains a safe and predictable method for treatment of stable SCFE with no AVN noted, even in severe slips. Attempts to anatomically reduce stable slips led to severe AVN in 20% of cases, thus this treatment approach should be considered with caution. Treatment of unstable slips remains problematic with high AVN rates noted whether treated by in situ fixation or capital realignment (Mod. Dunn). Level III retrospective comparative study.
Kabak, Sevki; Halici, Mehmet; Tuncel, Mehmet; Avsarogullari, Levent; Baktir, Ali; Basturk, Mustafa
2003-09-01
To evaluate functional outcomes, morbidity and mortality rates, and psychological and psychosomatic status in patients treated for completely unstable pelvic injuries (Tile class C). Prospective clinical study. University hospital. Forty patients treated with anterior and posterior internal fixation for unstable pelvic ring fractures between January 1992 and August 1999. Open reduction and anterior and posterior internal fixation of the pelvic ring. The data were analyzed as follows: pelvic fracture classification, Tile classification; severity of trauma, Injury Severity Score (ISS); functional outcomes, the Majeed Outcome Scale; psychological and psychosomatic status, Hamilton Depression and Anxiety Rating Score (HDARS). Preoperatively the average ISS was 29.4 (range 12-66). There was a statistically significant positive correlation between anxiety and ISS (r = 0.536, P < 0.01). Two patients died during the early postoperative period. Two additional patients were lost to follow-up, leaving 36 patients followed for an average of 45 months (range 21-116 months). Deep infections developed in three patients with a posterior pelvic ring injury who had been treated with percutaneous fixation techniques. These were treated successfully with débridement. Nine patients complained of pain of pelvic origin. Nerve deficits recovered completely in four of the seven patients with preoperative neurologic deficiency. Moderate or major depression was diagnosed in sexually dysfunctional patients in the 12th postoperative month according to HDARS (r = -0.559, P < 0.001). At the last visit, there was an inverse correlation between ability to work and depression and anxiety (r = -0.551, r = -0.391). An inverse correlation was found between pain and ability to work (r = 0.597, P < 0.001). Of the 36 patients, 26 returned to their original jobs at the last follow-up visit. Morbidity and mortality rates are higher in patients with a completely unstable pelvic ring injury. Emergency department stabilization and reconstruction of the pelvic ring with optimal operative techniques in these patients can reduce morbidity and mortality rates. Anterior and posterior internal fixation results in satisfactory clinical and radiologic outcomes. The affective status of patients is an important aspect that should be considered during the entire care of the patient.
Dai, Chong-Hua; Sun, Jun; Chen, Kun-Quan; Zhang, Hui-Bo
In the present study, we explored the effectiveness and complications of omnidirectional internal fixation using a double approach for treating Rüedi-Allgöwer type III pilon fractures. A retrospective analysis was performed of 19 cases of Rüedi-Allgöwer type III unilateral closed pilon fracture. With preoperative preparation and correct surgical timing, the reduction was performed using anteromedial and posterolateral approaches, and the fracture fragments were fixed by omnidirectional internal fixation. Imaging evaluation was performed using the Burwell-Charnley scoring system. The Johner-Wruhs scoring system was used to assess the functional status of the patients. A comprehensive evaluation of efficacy was performed using a 5-point Likert score. The complications were also recorded and analyzed. All patients were followed up for an average of 16.2 months. The operative incisions of 15 cases healed by primary intent and with delayed healing in 4. All patients had achieved bony union at an average of 16 weeks postoperatively. No deep infection, broken nail or withdrawn nail, exposed plate, or skin flap necrosis occurred. The Burwell-Charnley imaging evaluation showed that 14 patients had anatomic reduction of the articular surface and 5 had acceptable reduction. Using the Johner-Wruhs scoring system, the results were excellent for 8, good for 7, fair for 2, and poor for 2 patients; the combined rate of excellent and good results was 78.9%. The Likert score of efficacy self-reported by the patients was 3 to 4 points for 12 patients, 2 points for 4 patients, and 0 to 1 point for 3 patients. The Likert score of therapeutic efficacy reported by the physicians was 3 to 4 points for 10 patients, 2 points for 5 patients, and 0 to 1 point for 4 patients. Omnidirectional internal fixation using double approaches was an effective method to treat Rüedi-Allgöwer type III pilon fractures with satisfactory reduction and rigid fixation, good joint function recovery, and few complications. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
[Repair and reconstruction for severe fracture and dislocation of ankle joint].
Yin, Qingwei; Jiang, Yi; Xiao, Lianping; Li, Xiaodong; Fu, Jiaxin; Tian, Yonggang; Han, Liqiang; Liu, Zhi
2008-06-01
To summarize the technique and effect of the therapy for severe fracture and dislocation of ankle joint by operation. From March 2003 to February 2006, 76 cases were treated with primary open restoration and internal fixation for dislocated ankle joint fracture, with 47 males and 29 females, with the average age of 36.4 years (ranging from 18 years to 65 years). According to AO criterion, these fresh fractures were classified into 13 cases for type C3-1, 45 cases for type C3-2 and 18 cases for type C3-3. Based on the Gustilo-Anderson standard, 23 open fractures were classified into 17 cases for type II and 6 cases for type III A. The operation was delayed from 1 hours to 24 hours after the injury. All incisions healed at the first stage except 4 cases which delayed union because of simple infection by revision with ointment. A total of 72 cases were followed up, with the average time of 18.5 months (from 12 months to 35 months). The time of bone union was from 12 weeks to 24 weeks. The screws of fixation for lower tibia-fibula joint were found to be ruptured in 2 cases when further consultation was performed in the 16th and 20th week after the operation, respectively, and were broken within 1 year after the operation. These screws were taken out 12 weeks postoperative in 28 cases, while the whole internal fixations of the rest cases were taken out 1 year after the operation. The postoperative function of malleolus extended from 21.7 degrees to 26.8 degrees and flection from 38.5 degrees to 44.7 degrees. Assessed by the American Orthopaedic Foot and Ankle Society Clinical Rating Scales, 23 cases were excellent, 36 good, 13 fair, and the choiceness rate reached 81.94%. These procedures, together with reduction by twist after hospital, open and internal fixation in time, and parenchyma managed with internal fixation, are important to attain satisfactory effect for the treatment of severe fracture and dislocation of ankle joint.
Internal fixation of pilon fractures of the distal radius.
Trumble, T. E.; Schmitt, S. R.; Vedder, N. B.
1993-01-01
When closed manipulation fails to restore articular congruity in comminuted, displaced fractures of the distal radius, open reduction and internal fixation is required. Results of surgical stabilization and articular reconstruction of these injuries are reviewed in this retrospective study of 49 patients with 52 displaced, intra-articular distal radius fractures. Forty-three patients (87%) with a mean age of 37 years (range of 17 to 79 years) were available for evaluation. The mean follow-up time was 38 months (range 22-69 months). When rated according to the Association for the Study of Internal Fixation (ASIF), 19 were type C2 and 21 were type C3. We devised an Injury Score System based on the initial injury radiographs to classify severely comminuted intra-articular fractures and to identify those associated with carpal injury (3 patients). Post-operative fracture alignment, articular congruity, and radial length were significantly improved following surgery (p < .01). Grip strength averaged 69% +/- 22% of the contralateral side, and the range of motion averaged 75% +/- 18% of the contralateral side post-operatively. A combined outcome rating system that included grip strength, range of motion, and pain relief averaged 76% +/- 19% of the contralateral side. There was a statistically significant decrease in the combined rating with more severe fracture patterns as defined by the ASIF system (p < .01), Malone classification (p < .03), and the Injury Score System (p < .001). The Injury Score System presented here, and in particular the number of fracture fragments, correlated most closely with outcome of all the classification systems studied. Operative treatment of these distal radius fractures with reconstruction of the articular congruity and correction of the articular surface alignment with internal fixation and/or external fixation, can significantly improve the radiographic alignment and functional outcome. Furthermore, the degree to which articular stepoff, gap between fragments, and radial shortening are improved by surgery is strongly correlated with improved outcome, even when the results are corrected for severity of initial injury, whereas correction of radial tilt or dorsal tilt did not correlate with improved outcome. Images Figure 2 PMID:8209554
Hybrid Fixation for Ankle Fusion in Diabetic Charcot Arthropathy.
El-Mowafi, Hani; Abulsaad, Mazen; Kandil, Yasser; El-Hawary, Ahmed; Ali, Samer
2018-01-01
Ankle fusion is difficult to achieve in the diabetic Charcot ankle Brodsky type 3a because of the poor quality of the bone and the inability to achieve a stable biomechanical construct. The aim of this study was to report the outcome of ankle fusion using a combination of an intramedullary nail and a circular external fixator in patients with diabetic Charcot arthropathy. We prospectively studied 24 patients with diabetic Charcot arthropathy of the ankle who were treated by fusion of the tibiotalar joint using a combined retrograde intramedullary nail and Ilizarov external fixator. Their mean age was 50.7 ± 6.9 (range, 43-62) years. The mean follow-up after surgery was 36.4 ± 5.8 (range, 24-98) months. Twenty-two patients (92%) achieved clinical and radiographic solid bony fusion. No patients in this series needed amputation. All the patients were pain free, and the mean American Orthopaedic Foot & Ankle Society Score (AOFAS) improved significantly from 34.6 ± 6.8 to 66.4 ± 4.5 at the last follow-up. Two patients developed an ulcer over the heel due to a prominent nail. The ulcer healed after nail removal. Eight patients developed pin tract infection. We report a successful outcomes of ankle fusions using combined intramedullary nail locked only proximally and ring external fixator (hybrid fixation) in patients with diabetic Charcot arthropathy. Level IV, case series.
Mazur, Marcus D; Ravindra, Vijay M; Brockmeyer, Douglas L
2015-04-01
OBJECT Patients with occipitocervical (OC) instability from congenital vertebral anomalies (CVAs) of the craniocervical junction (CCJ) often have bony abnormalities that make instrumentation placement difficult. Within this patient population, some bilateral instrumentation constructs either fail or are not feasible, and a unilateral construct must be used. The authors describe the surgical management and outcomes of this disorder in patients in whom unilateral fixation constructs were used to treat OC instability. METHODS From a database of OC fusion procedures, the authors identified patients who underwent unilateral fixation for the management of OC instability. Patient characteristics, surgical details, and radiographic outcomes were reviewed. In each patient, CT scans were performed at least 4 months after surgery to evaluate for fusion. RESULTS Eight patients with CVAs of the CCJ underwent unilateral fixation for the treatment of OC instability. For 4 patients, the procedure occurred after a bilateral OC construct failed or infection forced hardware removal. For the remainder, it was the primary procedure. Two patients required reoperation for hardware revision and 1 developed nonunion requiring revision of the bone graft. Ultimately, 7 patients demonstrated osseous fusion on CT scans and 1 had a stable fibrous union. CONCLUSIONS These findings demonstrate that a unilateral OC fixation is effective for the treatment of OC instability in children with CVAs of the CCJ in whom bilateral screw placement fails or is not feasible.
Foveal analysis and peripheral selection during active visual sampling
Ludwig, Casimir J. H.; Davies, J. Rhys; Eckstein, Miguel P.
2014-01-01
Human vision is an active process in which information is sampled during brief periods of stable fixation in between gaze shifts. Foveal analysis serves to identify the currently fixated object and has to be coordinated with a peripheral selection process of the next fixation location. Models of visual search and scene perception typically focus on the latter, without considering foveal processing requirements. We developed a dual-task noise classification technique that enables identification of the information uptake for foveal analysis and peripheral selection within a single fixation. Human observers had to use foveal vision to extract visual feature information (orientation) from different locations for a psychophysical comparison. The selection of to-be-fixated locations was guided by a different feature (luminance contrast). We inserted noise in both visual features and identified the uptake of information by looking at correlations between the noise at different points in time and behavior. Our data show that foveal analysis and peripheral selection proceeded completely in parallel. Peripheral processing stopped some time before the onset of an eye movement, but foveal analysis continued during this period. Variations in the difficulty of foveal processing did not influence the uptake of peripheral information and the efficacy of peripheral selection, suggesting that foveal analysis and peripheral selection operated independently. These results provide important theoretical constraints on how to model target selection in conjunction with foveal object identification: in parallel and independently. PMID:24385588
Fixation, transient landscape, and diffusion dilemma in stochastic evolutionary game dynamics
NASA Astrophysics Data System (ADS)
Zhou, Da; Qian, Hong
2011-09-01
Agent-based stochastic models for finite populations have recently received much attention in the game theory of evolutionary dynamics. Both the ultimate fixation and the pre-fixation transient behavior are important to a full understanding of the dynamics. In this paper, we study the transient dynamics of the well-mixed Moran process through constructing a landscape function. It is shown that the landscape playing a central theoretical “device” that integrates several lines of inquiries: the stable behavior of the replicator dynamics, the long-time fixation, and continuous diffusion approximation associated with asymptotically large population. Several issues relating to the transient dynamics are discussed: (i) multiple time scales phenomenon associated with intra- and inter-attractoral dynamics; (ii) discontinuous transition in stochastically stationary process akin to Maxwell construction in equilibrium statistical physics; and (iii) the dilemma diffusion approximation facing as a continuous approximation of the discrete evolutionary dynamics. It is found that rare events with exponentially small probabilities, corresponding to the uphill movements and barrier crossing in the landscape with multiple wells that are made possible by strong nonlinear dynamics, plays an important role in understanding the origin of the complexity in evolutionary, nonlinear biological systems.
Liquifying PLDLLA Anchor Fixation in Achilles Reconstruction for Insertional Tendinopathy.
Boden, Stephanie A; Boden, Allison L; Mignemi, Danielle; Bariteau, Jason T
2018-04-01
Insertional Achilles tendinopathy (IAT) is a frequent cause of posterior heel pain and is often associated with Haglund's deformity. Surgical correction for refractory cases of IAT has been well studied; however, the method of tendon fixation to bone in these procedures remains controversial, and to date, no standard technique has been identified for tendon fixation in these surgeries. Often, after Haglund's resection, there is large exposed cancellous surface for Achilles reattachment, which may require unique fixation to optimize outcomes. Previous studies have consistently demonstrated improved patient outcomes after Achilles tendon reconstruction with early rehabilitation with protected weight bearing, evidencing the need for a strong and stable anchoring of the Achilles tendon that allows early weight bearing without tendon morbidity. In this report, we highlight the design, biomechanics, and surgical technique of Achilles tendon reconstruction with Haglund's deformity using a novel technique that utilizes ultrasonic energy to liquefy the suture anchor, allowing it to incorporate into surrounding bone. Biomechanical studies have demonstrated superior strength of the suture anchor utilizing this novel technique as compared with prior techniques. However, future research is needed to ensure that outcomes of this technique are favorable when compared with outcomes using traditional suture anchoring methods. Level V: Operative technique.
Contextual predictability enhances reading performance in patients with schizophrenia.
Fernández, Gerardo; Guinjoan, Salvador; Sapognikoff, Marcelo; Orozco, David; Agamennoni, Osvaldo
2016-07-30
In the present work we analyzed fixation duration in 40 healthy individuals and 18 patients with chronic, stable SZ during reading of regular sentences and proverbs. While they read, their eye movements were recorded. We used lineal mixed models to analyze fixation durations. The predictability of words N-1, N, and N+1 exerted a strong influence on controls and SZ patients. The influence of the predictabilities of preceding, current, and upcoming words on SZ was clearly reduced for proverbs in comparison to regular sentences. Both controls and SZ readers were able to use highly predictable fixated words for an easier reading. Our results suggest that SZ readers might compensate attentional and working memory deficiencies by using stored information of familiar texts for enhancing their reading performance. The predictabilities of words in proverbs serve as task-appropriate cues that are used by SZ readers. To the best of our knowledge, this is the first study using eyetracking for measuring how patients with SZ process well-defined words embedded in regular sentences and proverbs. Evaluation of the resulting changes in fixation durations might provide a useful tool for understanding how SZ patients could enhance their reading performance. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Dorsal or Volar Plate Fixation of the Distal Radius: Does the Complication Rate Help Us to Choose?
Disseldorp, D J G; Hannemann, P F W; Poeze, M; Brink, P R G
2016-08-01
Internal fixation with plates is a reliable fixation technique for the treatment of distal radius fractures. An ongoing discussion exists whether volar or dorsal plating is the appropriate technique. In clinical practice, volar plate fixation is usually preferred because of the assumed lower complication frequency. However, recent studies with the newer generation low-profile dorsal plates reported lower complication rates. The aim of our study was to evaluate the differences in complication rates between volar and dorsal plate for the treatment of distal radius fractures in adult patients. A total of 214 patients with acute distal radius fractures were included in this retrospective study with a minimum 2 years of follow-up. In total, 123 patients were treated with dorsal plate fixation and 91 patients with volar plate fixation. Our primary study outcome was complication rate. The overall risk for complications was 15.4% in the dorsal group and 14.3% in the volar group (p = 0.81). A total of 19 patients had implant removal due to complications: 11 patients in the dorsal group and 8 patients in the volar group (p = 0.97). There is no preferred plate fixation technique based on these study results. In our opinion, decision for type of plate fixation should be based on fracture type and surgeon's experience with the specific approach and plate types. Therapeutic level III.
Fracture healing using degradable magnesium fixation plates and screws.
Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles
2015-02-01
Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Miniplate fixation of Le Fort I osteotomies.
Rosen, H M
1986-12-01
The use of rigid, internal, three-dimensional fixation using vitallium bone plates in 28 consecutive Le Fort I osteotomies is presented. A minimum follow-up period of 6 months was required for inclusion in this patient group. Maxillary movements included advancements (17), intrusions (9), lengthenings (5), and retrusions (2). The majority of maxillae were moved in more than one plane of space. Technical details, complications, and relapse potential are discussed. Advantages of rigid plate fixation include marked reductions in the length of intermaxillary fixation with light training elastics only. Immediate postoperative airway problems are thereby eliminated. Six months of follow-up would appear to indicate a low potential for osseous relapse when compared to wire osteosynthesis, regardless of the direction of maxillary movement. The major disadvantage is the decreased ability of postoperative orthodontics to move dento-osseous segments if skeletal occlusal disharmony persists postoperatively. For this reason, close attention to preoperative planning and operative technique is critical for the success of this fixation method.
Giannotti, S; Giovannelli, D; Dell'Osso, G; Bottai, V; Bugelli, G; Celli, F; Citarelli, C; Guido, G
2016-04-01
The tibial plateau fractures involve one of the main weight bearing joints of the human body. The goals of surgical treatment are anatomical reduction, articular surface reconstruction and high primary stability. The aim of this study was to evaluate the clinical and functional outcomes after internal plate fixation of this kind of fractures. From January 2009 to December 2012, we treated 75 cases of tibial plateau fracture with angular stable plates. We used Rasmussen Score and the Knee Society Score for the clinical and functional evaluation. Twenty-five cases that underwent hardware removal had arthroscopic and CT evaluation of the joint. No complications occurred. The clinical and functional evaluation, performed by the KSS and Rasmussen Score, highlighted the high percentage of good-to-excellent results (over 90 %). In every case, the range of motion was good with flexion >90°. Arthroscopy showed the presence of chondral damage in 100 % of patients. In all the cases, we found that X-ray images seem better than the CT images. Angular stable plates allow to obtain a good primary stability, permitting an early joint recovery with an excellent range of motion. Avoiding to perform a knee arthrotomy at the time of fracture reduction could prove to be an advantage in terms of functional recovery. The meniscus on the injured bone should be preserved in order to maintain good function of the joint. X-ray images remain the gold standard in checking the progression of post-traumatic osteoarthritis.
Pelvic ring injuries: Surgical management and long-term outcomes
Halawi, Mohamad J.
2016-01-01
Pelvic ring injuries present a therapeutic challenge to the orthopedic surgeon. Management is based on the patient's physiological status, fracture classification, and associated injuries. Surgical stabilization is indicated in unstable injury patterns and those that fail nonsurgical management. The optimal timing for definitive fixation is not clearly defined, but early stabilization is recommended. Surgical techniques include external fixation, open reduction and internal fixation, and minimally invasive percutaneous osteosynthesis. Special considerations are required for concomitant acetabular fractures, sacral fractures, and those occurring in skeletally immature patients. Long-term outcomes are limited by lack of pelvis-specific outcome measures and burden of associated injuries. PMID:26908968
Late extensor pollicis longus rupture following plate fixation in Galeazzi fracture dislocation
Sabat, Dhananjaya; Dabas, Vineet; Dhal, Anil
2014-01-01
Late rupture of extensor pollicis longus (EPL) tendon after Galeazzi fracture dislocation fixation is an unknown entity though it is a well-established complication following distal radius fractures. We report the case of a 55-year old male who presented with late EPL tendon rupture 4 months following internal fixation of Galeazzi fracture dislocation with a Locking Compression Plate (LCP). He was managed with extensor indicis proprius (EIP) transfer to restore thumb extension. At 4 years followup, functional result of the transfer was good. We identify possible pitfalls with this particular patient and discuss how to avoid them in future. PMID:25143650
Ubiquitous Gammaproteobacteria dominate dark carbon fixation in coastal sediments.
Dyksma, Stefan; Bischof, Kerstin; Fuchs, Bernhard M; Hoffmann, Katy; Meier, Dimitri; Meyerdierks, Anke; Pjevac, Petra; Probandt, David; Richter, Michael; Stepanauskas, Ramunas; Mußmann, Marc
2016-08-01
Marine sediments are the largest carbon sink on earth. Nearly half of dark carbon fixation in the oceans occurs in coastal sediments, but the microorganisms responsible are largely unknown. By integrating the 16S rRNA approach, single-cell genomics, metagenomics and transcriptomics with (14)C-carbon assimilation experiments, we show that uncultured Gammaproteobacteria account for 70-86% of dark carbon fixation in coastal sediments. First, we surveyed the bacterial 16S rRNA gene diversity of 13 tidal and sublittoral sediments across Europe and Australia to identify ubiquitous core groups of Gammaproteobacteria mainly affiliating with sulfur-oxidizing bacteria. These also accounted for a substantial fraction of the microbial community in anoxic, 490-cm-deep subsurface sediments. We then quantified dark carbon fixation by scintillography of specific microbial populations extracted and flow-sorted from sediments that were short-term incubated with (14)C-bicarbonate. We identified three distinct gammaproteobacterial clades covering diversity ranges on family to order level (the Acidiferrobacter, JTB255 and SSr clades) that made up >50% of dark carbon fixation in a tidal sediment. Consistent with these activity measurements, environmental transcripts of sulfur oxidation and carbon fixation genes mainly affiliated with those of sulfur-oxidizing Gammaproteobacteria. The co-localization of key genes of sulfur and hydrogen oxidation pathways and their expression in genomes of uncultured Gammaproteobacteria illustrates an unknown metabolic plasticity for sulfur oxidizers in marine sediments. Given their global distribution and high abundance, we propose that a stable assemblage of metabolically flexible Gammaproteobacteria drives important parts of marine carbon and sulfur cycles.
Nebergall, Audrey; Bragdon, Charles; Antonellis, Anne; Kärrholm, Johan; Brånemark, Rickard; Malchau, Henrik
2012-04-01
Rehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling. 51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant. At 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up. The RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations.
Krappinger, Dietmar; Irenberger, Alexander; Zegg, Michael; Huber, Burkhart
2013-06-01
The treatment of large posttraumatic tibial bone defects using the Ilizarov method was shown to be successful in several studies. These studies, however, typically focus on the radiological and functional outcome using objective parameters only. The aim of the present study was therefore to assess the objective and subjective outcome of a consecutive series of patients with large posttraumatic tibial bone defects using the Ilizarov method. Additionally, it was our goal to assess the physical and mental stress for the patients and their relatives during the long treatment period and the general health status at final follow-up. A consecutive series of 15 patients with posttraumatic tibial bone defects of >30 mm after sustaining open tibial fractures and failure of internal fixation was included. The objective outcome was assessed at final follow-up using Paley's criteria. For the assessment of the subjective outcome, all patients were asked to evaluate their satisfaction with the function of the lower leg, the cosmetic appearance and overall outcome as well. The physical and mental stress of the treatment for the patients and the nearest relative of patients were assessed at the time of frame removal using a custom-made questionnaire. The SF-36 was used to evaluate the general health status at final follow-up. Solid bone union with stable soft tissue coverage and eradication of infection was achieved in all patients despite a high complication rate. The functional outcome at final follow-up was excellent or good in all patients. The patients' satisfaction with the overall outcome and the function of the lower extremity was high as well. The fear of amputation and complications was the major subjective burden for both the patients and their relatives. The long external fixation time is another relevant issue. The Ilizarov method is a safe option for the treatment of large posttraumatic tibial bone defects after failure of internal fixation despite the high complication rate. It is essential to comment this to the patients and their relatives prior to the application of the frame increase their compliance with the long and emotionally draining treatment. The Ilizarov method is worth the effort only in patients, who will presumably comply with this treatment option and all of its drawbacks.
Simon-type effects: chronometric evidence for keypress schemata in typewriting.
Logan, Gordon D
2003-08-01
In 4 experiments, chronometric evidence for keypress schemata in typing was sought by presenting stimuli to be typed in positions that were displaced from a central fixation point. Reaction times were shorter when stimulus positions corresponded to keyboard locations of the letters to be typed, suggesting that position was an important part of the internal representation of the response. Experiment 1 presented single letters left and right of fixation. Experiment 2 presented single letters above and below fixation. Experiment 3 presented words left and right of fixation and found evidence of parallel activation of keypress schemata. Experiment 4 found no effect of the eccentricity of the keyboard locations and responding fingers, suggesting that response-location codes are categorical, not metric. The results are consistent with D. E. Rumelhart and D. A. Norman's (1982) theory of typewriting.
Khan, M A; Hussain, R; Khan, S H; Umar, M
1997-11-01
Between 1993 and 1995, thirty-three patients having 39 fractures caused by missiles fired from a high velocity rifle were reviewed retrospectively between 1 and 3 years after injury and the outcome of treatment assessed. Majority (33 out of 39) were Grade III. Union was achieved in 35 out of 39 fractures, there was deep infection and delayed union in one case each. Non-union occurred in three fractures. The fractures were stabilized using different techniques, but highest complication rate was seen with the use of the static external fixator. This was related to the severe nature of the injury as well as the inherent limitations of the external fixator. Revision of the external fixator with internal fixation after healing of the soft tissues seems to be the direction of the future.
Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.
Wurm, Simone; Augat, Peter; Bühren, Volker
2015-09-01
To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests were performed under combined tension and bending until failure simulating physiological loading of the tibia during walking. Tension-band wiring failed at 66% of the failure load of plating (1052 N, P = 0.002) and had 5 times larger fracture gap displacements (P = 0.002). Based on the biomechanical advantages, locked plating of the patella may constitute a reasonable alternative in the treatment of patella fractures.
Ylikontiola, Leena; Sundqvuist, Kai; Sàndor, George K B; Törmälä, Pertti; Ashammakhi, Nureddin
2004-03-01
Bioresorbable osteofixation devices are being increasingly used in orthognathic surgery and in cases of trauma to avoid problems associated with conventional metal osteofixation devices. The aim of this clinical study was to assess the reliability and efficacy of bioresorbable self-reinforced poly-L/DL-lactide (SR-P(L/DL)LA 70/30) plates and screws in the fixation of mandibular fractures in adults. Ten patients (20 to 49 years old) with isolated anterior mandibular parasymphyseal fractures were treated by means of open reduction and internal fixation using SR-P(L/DL)LA 70/30 bioresorbable plates and screws. During the minimum of 6 months of follow-up, no problems were encountered except for 1 case where a plate became exposed intraorally and infected. This required debridement and later excision of the exposed part of the plate. Despite this setback the fractured bone healed well. SR-P(L/DL)LA 70/30 plates and screws are reliable for internal fixation of anterior mandibular fractures in adults. Proper soft tissue coverage should be ensured to avoid plate exposure. Should implant exposure occur, it might be necessary to excise the exposed part after fracture healing (6-8 weeks postoperatively).
Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.
Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C
1998-01-01
From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.
Diniz, Juliete M; Botelho, Ricardo V
2017-11-01
OBJECTIVE Thoracolumbar fractures account for 90% of spinal fractures, with the burst subtype corresponding to 20% of this total. Controversy regarding the best treatment for this condition remains. The traditional surgical approach, when indicated, involves spinal fixation and arthrodesis. Newer studies have brought the need for fusion associated with internal fixation into question. Not performing arthrodesis could reduce surgical time and intraoperative bleeding without affecting clinical and radiological outcomes. With this study, the authors aimed to assess the effect of fusion, adjuvant to internal fixation, on surgically treated thoracolumbar burst fractures. METHODS A search of the Medline and Cochrane Central Register of Controlled Trials databases was performed to identify randomized trials that compared the use and nonuse of arthrodesis in association with internal fixation for the treatment of thoracolumbar burst fractures. The search encompassed all data in these databases up to February 28, 2016. RESULTS Five randomized/quasi-randomized trials, which involved a total of 220 patients and an average follow-up time of 69.1 months, were included in this review. No significant difference between groups in the final scores of the visual analog pain scale or Low Back Outcome Scale was detected. Surgical time and blood loss were significantly lower in the group of patients who did not undergo fusion (p < 0.05). Among the evaluated radiological outcomes, greater mobility in the affected segment was found in the group of those who did not undergo fusion. No significant difference between groups in the degree of kyphosis correction, loss of kyphosis correction, or final angle of kyphosis was observed. CONCLUSIONS The data reviewed in this study suggest that the use of arthrodesis did not improve clinical outcomes, but it was associated with increased surgical time and higher intraoperative bleeding and did not promote significant improvement in radiological parameters.
Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi
2016-11-01
Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
A unique physeal injury of the distal phalanx
Berber, Onur; Singh, Bijayendra
2015-01-01
Abstract An unusual Salter–Harris Type 1 fracture variant of the distal phalanx of the index finger is described. The epiphysis was dislocated, sitting dorsally over the middle phalanx head with the articular surface facing dorsal. Reduction could only be achieved through an open procedure. The reduction was stable without supplemental fixation. PMID:27252957
Time for cotton to uptake water of a known isotopic signature as measured in leaf petioles
USDA-ARS?s Scientific Manuscript database
While stable isotopes of water have been used to study nutrient cycling, nitrogen fixation and other environmental studies they generally have not been used to examine shorter, more transient events, such as disposition of rainfall into soil water evaporation (E) and transpiration (T). With the deve...
Orthopaedic surgery in natural disaster and conflict settings: how can quality care be ensured?
Alvarado, Oscar; Trelles, Miguel; Tayler-Smith, Katie; Joseph, Holdine; Gesline, Rodné; Wilna, Thélusma Eli; Mohammad Omar, Mohammad Karim; Faiz Mohammad, Niaz Mohammad; Muhima Mastaki, John; Chingumwa Buhu, Richard; Caluwaerts, An; Dominguez, Lynette
2015-10-01
Médecins sans Frontières (MSF) is one of the main providers of orthopaedic surgery in natural disaster and conflict settings and strictly imposes a minimum set of context-specific standards before any surgery can be performed. Based on MSF's experience of performing orthopaedic surgery in a number of such settings, we describe: (a) whether it was possible to implement the minimum standards for one of the more rigorous orthopaedic procedures--internal fixation--and when possible, the time frame, (b) the volume and type of interventions performed and (c) the intra-operative mortality rates and postoperative infection rates. We conducted a retrospective review of routine programme data collected between 2007 and 2014 from three MSF emergency surgical interventions in Haiti (following the 2010 earthquake) and three ongoing MSF projects in Kunduz (Afghanistan), Masisi (Democratic Republic of the Congo) and Tabarre (Haiti). The minimum standards for internal fixation were achieved in one emergency intervention site in Haiti, and in Kunduz and Tabarre, taking up to 18 months to implement in Kunduz. All sites achieved the minimum standards to perform amputations, reductions and external fixations, with a total of 9,409 orthopaedic procedures performed during the study period. Intraoperative mortality rates ranged from 0.6 to 1.9 % and postoperative infection rates from 2.4 to 3.5 %. In settings affected by natural disaster or conflict, a high volume and wide repertoire of orthopaedic surgical procedures can be performed with good outcomes when minimum standards are in place. More demanding procedures like internal fixation may not always be feasible.
Shi, Jun; Yuan, Hao; Xu, Bing
2013-01-01
Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm). No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes. PMID:24386221
Spatial and temporal analysis of postural control in dyslexic children.
Gouleme, Nathalie; Gerard, Christophe Loic; Bui-Quoc, Emmanuel; Bucci, Maria Pia
2015-07-01
The aim of this study is to examine postural control of dyslexic children using both spatial and temporal analysis. Thirty dyslexic (mean age 9.7±0.3years) and thirty non-dyslexic age-matched children participated in the study. Postural stability was evaluated using Multitest Equilibre from Framiral®. Posture was recorded in the following conditions: eyes open fixating a target (EO) and eyes closed (EC) on stable (-S-) and unstable (-U-) platforms. The findings of this study showed poor postural stability in dyslexic children with respect to the non-dyslexic children group, as demonstrated by both spatial and temporal analysis. In both groups of children postural control depends on the condition, and improves when the eyes are open on a stable platform. Dyslexic children have spectral power indices that are higher than in non-dyslexic children and they showed a shorter cancelling time. Poor postural control in dyslexic children could be due to a deficit in using sensory information most likely caused by impairment in cerebellar activity. The reliability of brain activation patterns, namely in using sensory input and cerebellar activity may explain the deficit in postural control in dyslexic children. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Klonz, A; Habermeyer, P
2007-10-01
Arthrodesis of the glenohumeral joint is a difficult intervention that involves a relatively high probability of complications. A stable internal fixation and secure consolidation is required. The operation needs to achieve several conditions: thorough denudation of the cartilage and partial decortication of the subchondral bone; good congruence of the corresponding surfaces; compression of the gap by tension screws and lasting stability. For increased primary stability a neutralizing plate is generally used as well as a compression screw. Up to now, the plate has usually been applied starting from the scapular spine and extending across the acromial corner to the humeral shaft. A wide exposure is needed for this procedure; the plate is difficult to shape during the operation and often causes some discomfort because it protrudes at the acromial corner. We present an alternative position of the plate in the supraspinatus fossa, where we have sited a 4.5 mm LCP locking plate (Synthes). The implant is inserted under the acromion, does not cause any discomfort at the acromial corner, and is far easier to shape. When it is used in association with a transarticular compressive screw, the technique results in a very stable situation, which allows physiotherapy from the first day after surgery onward.
Miller, Timothy L; Skalak, Timothy
2014-02-01
Ankle ligamentous injuries are commonly seen in athletes in a variety of sports. Surveys of physicians and trainers of professional sports teams have identified syndesmotic injuries as among the most difficult to treat. In particular, injuries of the ankle syndesmosis have been strongly linked with a prolonged recovery and increased time to return to play. Due to sudden external rotation with the tibiotalar joint in dorsiflexion, these structures are commonly injured in association with fractures of the distal fibula. Surgery is indicated in cases with associated fractures and ligamentous instability, but optimal treatment for syndesmosis injuries without an associated fracture is less clear. A thorough history and physical examination, as well as appropriate imaging, are necessary to effectively diagnose and classify the injury. For stable injuries, short-term immobilization and functional rehabilitation is recommended. Unstable Grade 2 and 3 injuries require surgical fixation. Debate currently exists over rigid screw fixation versus suture button techniques as the ideal fixation method.
The dynamic volume changes of polymerising polymethyl methacrylate bone cement.
Muller, Scott D; Green, Sarah M; McCaskie, Andrew W
2002-12-01
The Swedish hip register found an increased risk of early revision of vacuum-mixed cemented total hip replacements. The influence of cement mixing technique on the dynamic volume change in polymerising PMMA is not well understood and may be relevant to this observation. Applying Archimedes' principle, we have investigated the dynamic volume changes in polymerising cement and determined the influence of mixing technique. All specimens showed an overall volume reduction: hand-mixed 3.4% and vacuum-mixed 6.0%. Regression analysis of sectional porosity and volume reduction showed a highly significant relationship. Hand-mixed porous cement showed a transient volume increase before solidification. However, vacuum-mixed cement showed a progressive volume reduction throughout polymerisation. Transient expansion of porous cement occurs at the critical time of micro-interlock formation, possibly improving fixation. Conversely, progressive volume reduction of vacuum-mixed cement throughout the formation of interlock may damage fixation. Stable fixation of vacuum-mixed cement may depend on additional techniques to offset the altered volumetric behaviour of vacuum-mixed cement.
A single evolutionary innovation drives the deep evolution of symbiotic N2-fixation in angiosperms
Werner, Gijsbert D. A.; Cornwell, William K.; Sprent, Janet I.; Kattge, Jens; Kiers, E. Toby
2014-01-01
Symbiotic associations occur in every habitat on earth, but we know very little about their evolutionary histories. Current models of trait evolution cannot adequately reconstruct the deep history of symbiotic innovation, because they assume homogenous evolutionary processes across millions of years. Here we use a recently developed, heterogeneous and quantitative phylogenetic framework to study the origin of the symbiosis between angiosperms and nitrogen-fixing (N2) bacterial symbionts housed in nodules. We compile the largest database of global nodulating plant species and reconstruct the symbiosis’ evolution. We identify a single, cryptic evolutionary innovation driving symbiotic N2-fixation evolution, followed by multiple gains and losses of the symbiosis, and the subsequent emergence of ‘stable fixers’ (clades extremely unlikely to lose the symbiosis). Originating over 100 MYA, this innovation suggests deep homology in symbiotic N2-fixation. Identifying cryptic innovations on the tree of life is key to understanding the evolution of complex traits, including symbiotic partnerships. PMID:24912610
Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M
2007-12-01
Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.
A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty
Marsland, Daniel; Mears, Simon C.
2012-01-01
Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704
Sarkar, Saikat; Bandyopadhyay, Ranadeb; Mukherjee, Arindam
2013-01-01
Femoral shaft fracture is the most common major paediatric orthopaedic. For generations traction and casting was the standard treatment for all femoral shaft fractures in children. Over the past two decades the advantages of fixation and rapid mobilisation have been increasingly recognised. A prospective study was conducted in five private hospitals in the district of Bankura, West Bengal over a period of two years (April 2010 to March 2012) on 70 patients with closed shaft femur fractures between 6- 14 years age of either sex. The aim was to find out the short term complications of titanium elastic nailing in diaphyseal fracture of femur in children and compare the findings of this study with pre- existing studies in this field. In our study the most common complication was pain at nail entry site (60%). 5.71% had local inflammatory reaction due to nails. Superficial infection occurred in 2.85%. At the end of 1 year, 2.85% had limb length discripancies. Proximal migration occurred in 2.85%. 2.85% encountered acute reactive synovitis, 5.71% developed angulation of fracture site and 2.85% developed per operative breakage of nail. The treatment of paediatric shaft femur fracture has been drastically changed over the last two decades to internal fixation by elastically stable intra- medullary nail (ESIN). In our study, we encountered only a few complications most of them being minor. Most of the complications were surgical technique related and were seen at the initial phase of the learning curve.
Femoral Reconstruction Using External Fixation
Palatnik, Yevgeniy; Rozbruch, S. Robert
2011-01-01
Background. The use of an external fixator for the purpose of distraction osteogenesis has been applied to a wide range of orthopedic problems caused by such diverse etiologies as congenital disease, metabolic conditions, infections, traumatic injuries, and congenital short stature. The purpose of this study was to analyze our experience of utilizing this method in patients undergoing a variety of orthopedic procedures of the femur. Methods. We retrospectively reviewed our experience of using external fixation for femoral reconstruction. Three subgroups were defined based on the primary reconstruction goal lengthening, deformity correction, and repair of nonunion/bone defect. Factors such as leg length discrepancy (LLD), limb alignment, and external fixation time and complications were evaluated for the entire group and the 3 subgroups. Results. There was substantial improvement in the overall LLD, femoral length discrepancy, and limb alignment as measured by mechanical axis deviation (MAD) and lateral distal femoral angle (LDFA) for the entire group as well as the subgroups. Conclusions. The Ilizarov external fixator allows for decreased surgical exposure and preservation of blood supply to bone, avoidance of bone grafting and internal fixation, and simultaneous lengthening and deformity correction, making it a very useful technique for femoral reconstruction. PMID:21991425
Schönbach, Etienne M; Strauss, Rupert W; Kong, Xiangrong; Muñoz, Beatriz; Ibrahim, Mohamed A; Sunness, Janet S; Birch, David G; Hahn, Gesa-Astrid; Nasser, Fadi; Zrenner, Eberhart; Sadda, SriniVas R; West, Sheila K; Scholl, Hendrik P N
2018-06-08
To investigate the natural history of Stargardt disease (STGD1) using fixation location and fixation stability. Multicenter, international, prospective cohort study. Fixation testing was performed using the Nidek MP-1 microperimeter as part of the prospective, multicenter, natural history study on the Progression of Stargardt disease (ProgStar). A total of 238 patients with ABCA4-related STGD1 were enrolled at baseline (bilateral enrollment in 86.6 %) and underwent repeat testing at month 6 and 12. Outcome measures included the distance of the preferred retinal locus from the fovea (PRL) and the bivariate contour ellipse area (BCEA). After 12 months of follow-up, the change in the eccentricity of the PRL from the anatomical fovea was -0.0014 deg (95 % CI, - 0.27deg - 0.27 deg; p = 0.99). The deterioration in the stability of fixation as expressed by a larger BCEA encompassing 1 SD of all fixation points was 1.21 deg 2 (95 % CI, -1.23 deg 2 , 3.65 deg 2 ; p = 0.33). Eyes with increases and decreases in PRL eccentricity and/or BCEA values were observed. Our observations point to the complexity of fixation parameters. The association of increasingly eccentric and unstable fixation with longer disease duration that is typically found in cross-sectional studies may be countered within individual patients by poorly understood processes like neuronal adaptation. Nevertheless, fixation parameters may serve as useful secondary outcome parameters in selected cases and for counseling patients to explain changes to their visual functionality. Copyright © 2018 Elsevier Inc. All rights reserved.
Bumči, Igor; Vlahović, Tomislav; Jurić, Filip; Žganjer, Mirko; Miličić, Gordana; Wolf, Hinko; Antabak, Anko
2015-11-01
Paediatric ankle fractures comprise approximately 4% of all paediatric fractures and 30% of all epiphyseal fractures. Integrity of the ankle "mortise", which consists of tibial and fibular malleoli, is significant for stability and function of the ankle joint. Tibial malleolar fractures are classified as SH III or SH IV intra-articular fractures and, in cases where the fragments are displaced, anatomic reposition and fixation is mandatory. Type SH III-IV fractures of the tibial malleolus are usually treated with open reduction and fixation with cannulated screws that are parallel to the physis. Two K-wires are used for temporary stabilisation of fragments during reduction. A third "guide wire" for the screw is then placed parallel with the physis. Considering the rules of mechanics, it is assumed that the two temporary pins with the additional third pin placed parallel to the physis create a strong triangle and thus provide strong fracture fixation. To prove this hypothesis, an experiment was conducted on the artificial models of the lower end of the tibia from the company "Sawbones". Each model had been sawn in a way that imitates the fracture of medial malleoli and then reattached with 1.8mm pins in various combinations. Prepared models were then tested for tensile and pressure forces. The least stable model was that in which the fractured pieces were attached with only two parallel pins. The most stable model comprised three pins, where two crossed pins were inserted in the opposite compact bone and the third pin was inserted through the epiphysis parallel with and below the growth plate. A potential method of choice for fixation of tibial malleolar fractures comprises three K-wires, where two crossed pins are placed in the opposite compact bone and one is parallel with the growth plate. The benefits associated with this method include shorter operating times and avoidance of a second operation for screw removal. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ramasamy, P R
2017-01-01
Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.
Biomechanics of far cortical locking.
Bottlang, Michael; Feist, Florian
2011-02-01
The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.
Biomechanics of Far Cortical Locking
Bottlang, Michael; Feist, Florian
2011-01-01
The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556
Predictors of Time to Union After Operative Fixation of Closed Ankle Fractures.
Matson, Andrew P; Hamid, Kamran S; Adams, Samuel B
2017-08-01
Ankle fractures are common and represent a significant burden to society. We aim to report the rate of union as determined by clinical and radiographic data, and to identify factors that predict time to union. A cohort of 112 consecutive patients with isolated, closed, operative malleolar ankle fractures treated with open reduction and internal fixation was retrospectively reviewed for time to clinical union. Clinical union was defined based on radiographic and clinical parameters, and delayed union was defined by time to union >12 weeks. Injury characteristics, patient factors and treatment variables were recorded, and statistical techniques employed included the Chi-square test, the Student's T-test, and multivariate linear regression modeling. Forty-two (37.5%) of patients who achieved union did so in less than 12 weeks, and 69 (61.6%) of these patients demonstrated delayed union at a mean of 16.7 weeks (range, 12.1-26.7 weeks), and the remaining patient required revision surgery. Factors associated with higher rates of delayed union or increased time to union included tobacco use, bimalleolar fixation, and high energy mechanism (all p<0.05). In regression analysis, statistically significant negative predictors of time to union were BMI, dislocation of the tibiotalar joint, external fixation for initial stabilization and delay of definitive management (all p<0.05). Patient characteristics, injury factors and treatment variables are predictive of time to union following open reduction and internal fixation of closed ankle fractures. These findings should assist with patient counseling, and help guide the provider when considering adjunctive therapies that promote bone healing. Prognostic, Level IV: Case series.
Li, Cheng; Li, Lei; Duan, Jingzhu; Zhang, Lijun; Liu, Zhenjiang
2018-05-01
This study aimed to describe the case of a 3-year-old girl with old bilateral facet dislocation on cervical vertebrae 6 and 7, who had spinal cord transection, received surgical treatment, and achieved a relative satisfactory therapeutic effect. A 3-year-old girl was urgently transferred to the hospital after a car accident. DIAGNOSES:: she was diagnosed with splenic rupture, intracranial hemorrhage, cervical dislocation, spinal transection, and Monteggia fracture of the left upper limb. The girl underwent emergency splenectomy and was transferred to the intensive care unit of the hospital 15 days later. One-stage anterior-posterior approach surgery (anterior discectomy, posterior laminectomy, and pedicle screw fixation) was performed when the patient stabilized after 45-day symptomatic treatment. The operation was uneventful. The reduction of lower cervical dislocation was satisfactory, with sufficient spinal cord decompression. The internal fixation position was good, and the spinal sequence was well restored. The girl was discharged 2 weeks later after the operation and followed up for 2 years. The major nerve function of both upper limbs was recovered, with no obvious retardation of the growth of immature spine. A satisfactory therapeutic effect was achieved for a pediatric old subaxial cervical dislocation with bilateral locked facets using anterior discectomy, posterior laminectomy, and pedicle screw fixation. The posterior pedicle screw fixation provided a good three-dimensional stability of the spine, with reduced risk and complications caused by anterior internal fixation. The growth of immature spine was not obviously affected during the 2-year follow-up.
Research perspectives in first metatarsal osteotomy and fixation stability.
Landsman, A S; Higgins, K R; Lampe, N
1996-07-01
Well-designated research is required to provide clinical guidance by validation of old and new methods. Variables, including technologic advancement in surgical techniques, diagnosis, shoe design, and immobilization all contribute to the challenge of investigating surgical procedures of the foot. This article highlights some of the relevant research pertaining to first metatarsal osteotomies and internal fixation and provides direction for potential, future research. Numerous aspects about the research techniques involved are discussed.
Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.
Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed
2015-09-01
This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3-12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact.
Check radiography after fixation of hip fractures: is it necessary?
Mohanty, K; Gupta, S K; Evans, R M
2000-12-01
Technological advances in radiography in the form of image intensification has not only made internal fixation of femoral neck fracture much easier but these high resolution films can be saved as hard copies and can also be reversed into 'positives' at a later date. However, requesting routine post-operative check radiographs for these fractures are still a common practice. A retrospective study was carried out to compare the quality of image intensifier films with conventional post-operative radiographs. 79 sets of films were reviewed with particular reference to adequacy of fixation and possible joint penetration by the screws. No significant difference was noted between the two sets of films. We suggest that routine post-operative radiographs after femoral neck fracture fixation are unnecessary unless there is some clinical indication. This has significant implications in relation to patient discomfort, radiation exposure and cost-effectiveness.
Malunited fracture of the body and condyle of the mandible : A Case Report.
Yeluri, Ramakrishna; Baliga, Sudhindra; Munshi, Autar Krishen
2010-07-01
Mandibular fractures are the most common facial fractures seen in hospitalized children and their incidence increases with age. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. Many factors complicate the management of pediatric mixed-dentition mandibular fractures: tooth eruption, short roots, developing tooth buds and growth issues. One major factor is the inherent instability of the occlusion in the mixed deciduous-permanent tooth phase. This case report documents a child in mixed dentition period with a complication arising due to direct fixation of the fractured mandible.
Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru
2013-11-01
The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.
Firoozabadi, Reza; Kramer, Patricia A; Benirschke, Stephen K
2013-11-01
Although Kirschner wires are useful implants in many situations, migration of the wire and irritation of the surrounding soft tissues are common complications. Seven steps are described herein, which result in a Kirschner wire that is bent 180° angle, providing a smooth anchor into bone. Use of this technique produces implants that provide stable fixation with few soft tissue complications.
HETEROGENETIC ANTIBODIES IN ACUTE HEPATITIS
Eaton, Monroe D.; Murphy, William D.; Hanford, V. Lee
1944-01-01
A heterogenetic antibody showing fixation of complement with human liver and agglutination of sheep erythrocytes was found in certain cases of acute infective hepatitis. The antigen concerned in these reactions was apparently heat stable and alcohol soluble. Differences from other heterogenetic antigen-antibody systems have been noted. The possible relation of the heterogenetic antibody to liver damage was considered. PMID:19871386
Wang, Xi-Xun; Sun, De-Tao; Chen, Xu-Hui; Li, Jun; Cui, Yan; Hu, Ji-Chao; Shu, Zheng-Hua; He, Jian; Ding, Chao-Qi; Chen, Bo
2015-03-01
To study clinical effects of one-hole microplate internal fixation for the treatment of collateral ligament injuries of the metacarpophalangeal joint of the thumb combined with fracture. Twenty-two patients (16 males, 6 females) with collateral ligament injuries of the metacarpophalangeal joint of the thumb combined fracture were treated with one-hole microplate internal fixation. The age of the patients ranged from 18 to 53 years old with a mean age of 28.5 years old. The duration from injury to surgery ranged from 2 hours to 2 months, and the mean time was 6 days. All the patients had collateral ligament injuries combined with fracture of the metacarpophalangeal joint of the thumb. Thirteen patients had injuries in the right hand and 9 patients had injuries in the left hand. There were 18 cases of closed wound and 4 cases of open wound. Eighteen patients had fresh injuries (< 2 weeks) and 4 had old injuries (> 2 weeks). Sixteen patients had injuries in the ulnar collateral ligament of the thumb combined with fracture, 6 patients had radial collateral ligament injuries of the thumb combined with fracture, 4 cases of which were complicated with injuries of abductor pollicis brevis and the end of the flexor pollicis brevis tender. The size of the avulsed fragment was about 3.0 mm x 4.0 mm to 6.0 mm x 7.0 mm. The incisions of 22 patients healed by first intention. The follow-up periods ranged from 6 months to 5 years old,with an average of 2.5 years old. The thumb function was evaluated by Saetta and other evaluation criteria, and 20 patients got an excellent result and 2 good. The application of one-hole microplate internal fixation in treating collateral ligament injuries with fracture of the metacarpophalangeal joint of the thumb is an effective method.
Hao, Qing-Ying; Liu, Chu-Yin; Fu, Chan-Juan; Zhang, Xiao-Hua; Tan, Ming-Sheng
2016-01-01
Background: Continuous negative pressure drainage (CNPD) is widely used after lower lumbar internal fixation; however, it may cause tremendous blood loss and lead to postoperative hemorrhagic anemia. The present study explored the efficacy and safety of improved intermittent-clamped drainage (ICD) for lower lumbar internal fixation. Methods: This was a prospective study that included 156 patients with decompression of the spinal canal and internal fixation for the first time from January 2012 to December 2014. The patients were randomly divided into ICD group and CNPD group, and each group had 78 cases. A drainage tube was placed under the deep fascia in all patients within 10 min after the commencement of wound closure. The postoperative drainage amount at different time points, the hemoglobin level, and postoperative complications were recorded and compared between the two groups. Shapiro-Wilk test, independent samples t-test, and Mann-Whitney U-test were used in this study. Results: The drainage amount was significantly reduced in the ICD group, as compared with the CNPD group (Z = 10.74, P < 0.01). The mean total drainage amount (in ml) of the single-segment and two-segment procedures was significantly greater in the CNPD group than the ICD group (Z = 10.63 and 10.75, respectively; P < 0.01). For the adverse events, there was no significant difference in postoperative temperature, wound problem, and complications between the two groups. Conclusions: The present study showed a statistically significant reduction in postoperative drainage amount between ICD and CNPD groups, and ICD is an effective, convenient, and safe method for routine use in lower lumbar surgery. It is essential to focus on the effect of clamping drainage with long-segment surgical procedure and complex lumbar disease in the further investigation, as well as the effect of clamping on long-term functional outcomes. PMID:27900992
Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang
2016-02-01
Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting, and internal fixation can be completed with only one incision and surgical position, and the deformity correction efficiency is higher than anterior surgery. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.
Processing and evaluation of long fiber thermoplastic composite plates for internal fixation
NASA Astrophysics Data System (ADS)
Warren, Paul B.
The metallic plates used in internal fracture fixation may have up to ten times the elastic modulus of normal bone tissue, causing stress shielding-induced osteopenia in healed bone that can lead to re-fracture after plate removal and prolonged and painful recovery. Thermoplastic polymer matrix composites reinforced with long carbon fiber are promising alternative materials for internal fixation plates because they may be produced with relative ease and be tailored to have specific mechanical properties, alleviating the stress shielding problem. Long carbon fiber-reinforced polyetheretherketone (LCF PEEK) plates were produced using the extrusion / compression molding process. Static flexural testing determined that LCF PEEK plates with rectangular cross-section had an average flexural modulus of 12 GPa, or 23% of the flexural modulus of a stainless steel plate. The LCF PEEK plates also experienced negligible (14.7%, 14.5%, and 16.7%) reductions in modulus after fatigue testing at applied moments of 2.5, 3.0, and 3.5 N•m, respectively, over 106 load cycles. Aging the plates in 0.9% NaCl solution for four and eight weeks caused 0.34% and 0.28% increases in plate mass, respectively. No significant decrease of flexural properties due to aging was detected. Differential scanning calorimetry (DSC) revealed the PEEK matrix of the plates to be 24.5% crystalline, which is lower than typical PEEK crystallinity values of 30-35%. Scanning electron microscopy (SEM) revealed three times as many fiber pullout areas in LCF PEEK fracture surfaces as in fracture surfaces of long carbon fiber-reinforced polyphenylenesulfide (LCF PPS), another plate material tested. DSC and SEM data suggest that improvements in processing conditions and fiber/matrix bonding, along with higher carbon fiber fractions, would enhance LCF PEEK plate performance. LCF PEEK remains a promising alternative to stainless steel for internal fixation plates.
NASA Astrophysics Data System (ADS)
Hellweg, Christine E.; Dilruba, Shahana; Adrian, Astrid; Feles, Sebastian; Schmitz, Claudia; Berger, Thomas; Przybyla, Bartos; Briganti, Luca; Franz, Markus; Segerer, Jürgen; Spitta, Luis F.; Henschenmacher, Bernd; Konda, Bikash; Diegeler, Sebastian; Baumstark-Khan, Christa; Panitz, Corinna; Reitz, Günther
2015-11-01
One factor contributing to the high uncertainty in radiation risk assessment for long-term space missions is the insufficient knowledge about possible interactions of radiation with other spaceflight environmental factors. Such factors, e.g. microgravity, have to be considered as possibly additive or even synergistic factors in cancerogenesis. Regarding the effects of microgravity on signal transduction, it cannot be excluded that microgravity alters the cellular response to cosmic radiation, which comprises a complex network of signaling pathways. The purpose of the experiment ;Cellular Responses to Radiation in Space; (CELLRAD, formerly CERASP) is to study the effects of combined exposure to microgravity, radiation and general space flight conditions on mammalian cells, in particular Human Embryonic Kidney (HEK) cells that are stably transfected with different plasmids allowing monitoring of proliferation and the Nuclear Factor κB (NF-κB) pathway by means of fluorescent proteins. The cells will be seeded on ground in multiwell plate units (MPUs), transported to the ISS, and irradiated by an artificial radiation source after an adaptation period at 0 × g and 1 × g. After different incubation periods, the cells will be fixed by pumping a formaldehyde solution into the MPUs. Ground control samples will be treated in the same way. For implementation of CELLRAD in the Biolab on the International Space Station (ISS), tests of the hardware and the biological systems were performed. The sequence of different steps in MPU fabrication (cutting, drilling, cleaning, growth surface coating, and sterilization) was optimized in order to reach full biocompatibility. Different coatings of the foil used as growth surface revealed that coating with 0.1 mg/ml poly-D-lysine supports cell attachment better than collagen type I. The tests of prototype hardware (Science Model) proved its full functionality for automated medium change, irradiation and fixation of cells. Exposure of HEK cells to the β-rays emitted by the radiation source dose-dependently decreased cell growth and increased NF-κB activation. The signal of the fluorescent proteins after formaldehyde fixation was stable for at least six months after fixation, allowing storage of the MPUs after fixation for several months before the transport back to Earth and evaluation of the fluorescence intensity. In conclusion, these tests show the feasibility of CELLRAD on the ISS with the currently available transport mechanisms.
Greenhagen, Robert M; Highlander, Peter D; Burns, Patrick R
2012-01-01
Avulsion fractures of the calcaneal tuberosity represent only 1.3% to 2.7% of calcaneal fractures. These fractures are common pathologically in nature and attributed to decreased bone mineral density. Calcaneal insufficiency avulsion (CIA) fracture in patients with diabetes mellitus is most likely due to Charcot neuroarthropathy (CN) as described by the Brodsky classification (Brodsky 3B). Traditional open reduction and internal fixation is difficult in all calcaneal avulsion fractures because of poor bone quality. The authors report the first known description of the use of fracture fragment excision and double row anchor fixation.A 39-year-old woman with type I diabetes mellitus and a history of CN presented with an avulsion fracture of the calcaneal tuberosity. Excision of the fracture fragment and a gastrocnemius recession and reattachment of the Achilles tendon with double row anchor fixation to the calcaneus were performed. At 1 year, the patient's American Orthopaedic Foot & Ankle Society rearfoot score improved from 27/100 to 88/100. CIA fractures are an infrequently described injury. Because diabetes mellitus is frequently associated with this disease, it most likely represents a CN event. Traditionally, CIA fractures have been operatively treated with open reduction internal fixation. Previous authors have described difficulty with fixation because of poor quality. In the current report, the authors describe a novel operative approach to CIA fractures through the use of double row anchor fixation and excision of the fracture fragments. The authors feel that this previously undescribed treatment is superior to traditional methods and may serve as a new treatment option for all patients who have sustained this unusual pathology regardless of the underlying cause. The current authors provide a novel operative technique that provides inherent advantages to the traditional repair of CIA fractures. We believe CIA fractures represent a CN-type event and care should be taken when evaluating and treating these patients to prevent further sequelae. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Zhonghua; Han, Xuesong; Li, Xiaolei; Qin, Xiaofei
2018-04-01
To report the surgical technique and clinical outcomes for the treatment of AAD with atlas assimilation by single-stage posterior reduction and fixation applying intraoperative distraction between occipital and C2 screws. From April 2008 to January 2014, 25 patients underwent single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws. The pre- and postoperative radiologic parameters and JOA score were examined. Follow-up ranged from 6 to 17months in 25 patients. Clinical symptoms improved in 24 patients (96%) and were stable in 1 patient (4%). Radiologic assessment illustrated that complete reduction was achieved in 24 patients and partial reduction (>60%) in 1 patient. Overall, satisfactory decompression and reduction were showed on postoperative MRT and 3D-CT scans of all 25 patients. The single-stage posterior reduction and fixation applying occipital plate, C2 screws and rigid cantilever beam system through intraoperative distraction between occipital and C2 screws for AAD with atlas assimilation is simple, fast, safe and effective. C1 screws insertion for the treatment of AAD with atlas assimilation should be considered.
Cardini, Ulisse; Bednarz, Vanessa N.; Naumann, Malik S.; van Hoytema, Nanne; Rix, Laura; Foster, Rachel A.; Al-Rshaidat, Mamoon M. D.; Wild, Christian
2015-01-01
Functional traits define species by their ecological role in the ecosystem. Animals themselves are host–microbe ecosystems (holobionts), and the application of ecophysiological approaches can help to understand their functioning. In hard coral holobionts, communities of dinitrogen (N2)-fixing prokaryotes (diazotrophs) may contribute a functional trait by providing bioavailable nitrogen (N) that could sustain coral productivity under oligotrophic conditions. This study quantified N2 fixation by diazotrophs associated with four genera of hermatypic corals on a northern Red Sea fringing reef exposed to high seasonality. We found N2 fixation activity to be 5- to 10-fold higher in summer, when inorganic nutrient concentrations were lowest and water temperature and light availability highest. Concurrently, coral gross primary productivity remained stable despite lower Symbiodinium densities and tissue chlorophyll a contents. In contrast, chlorophyll a content per Symbiodinium cell increased from spring to summer, suggesting that algal cells overcame limitation of N, an essential element for chlorophyll synthesis. In fact, N2 fixation was positively correlated with coral productivity in summer, when its contribution was estimated to meet 11% of the Symbiodinium N requirements. These results provide evidence of an important functional role of diazotrophs in sustaining coral productivity when alternative external N sources are scarce. PMID:26511052
NiTiNol Hernia Device Stability in Inguinal Hernioplasty Without Fixation
2011-01-01
Background and Objective: To determine whether the NiTiNol frame of a novel hernia repair device utilizing polypropylene mesh for inguinal hernioplasty remains stable and intransient without fixation after a minimum of 6 months. Methods: Twenty patients had 27 inguinal hernias repaired using a novel hernia repair device that has a NiTiNol frame without any fixation. Initial single-view, postoperative X-rays were compared with a second X-ray obtained at least 6 months later. The NiTiNol frame, which can be easily visualized on a plain X-ray, was measured in 2 dimensions, as were anatomic landmarks. The measurements obtained and the appearances of the 2 X-rays were compared to determine the percentage of change in device size and device stability with regard to device location and shape. Results: There were minimal changes noted between the 2 sets of measurements obtained with an overall trend towards a slight increase in the size of the hernia repair device. The devices demonstrated intransience of position and stability of shape. Conclusions: The NiTiNol frame of a novel hernia repair device utilizing polypropylene mesh exhibits radiographic evidence of size and shape stability and intransience of position without fixation when used in inguinal hernioplasty after a minimum follow-up of 6 months. PMID:21902967
Ilizarov ring fixator for a difficult case of ankle syndesmosis disruption.
Relwani, Jaikumar; Lahoti, Om; Orakwe, Sam
2002-01-01
Syndesmotic stabilization is recommended for tibiofibular diastasis, a Maisonneuve fracture, or syndesmotic instability after fixation of distal tibia-fibula fractures. In the case presented, a syndesmotic stabilization was performed with a screw inserted 2 cm above the tibiotalar joint Subsequent failure occurred due to the weight of the patient and a lack of compliance with the necessary nonweight bearing protocol. The Ilizarov frame was used to reduce and maintain a stable syndesmosis with a simple two-ring construct which allowed the patient to bear weight on the injured limb while his syndesmosis healed. This is not recommend as a routine method of treatment, but is presented as an extended indication of the Ilizarov frame for difficult cases.
Meling, Terje; Harboe, Knut; Søreide, Kjetil
2009-11-01
Musculoskeletal trauma represents a considerable global health burden; however, reliable population-based incidence data are lacking. Thus, we prospectively investigated the age- and sex-specific incidence patterns of long-bone fractures in a defined population. A 4-year prospective study of all long-bone fractures in a defined Norwegian population was carried out. The demographic data, as well as data on fracture type and location and mode of treatment were collected using recognised classification (e.g., AO/OTA - Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association; Gustilo-Anderson (GA) for open fractures). Age- and sex-adjusted incidences were calculated using population statistics. During the study period, 4890 long-bone fractures were recorded. The overall incidence per 100,000 per year was 406 with a 95% confidence interval (95%CI) of 395-417. The age-adjusted incidence for those <16 years (339; 95%CI: 318-360) was lower than that for those >or=16 years (427; 95%CI: 414-440). The overall male incidence (337; 95%CI: 322-355) was lower than the female (476; 95%CI: 459-493), but the male:female ratio was 2:1 among those <50 years, and 1:3 in those >or=50 years. The upper limb fractures had an overall incidence of 159 (95%CI: 152-166), whereas the lower limb fracture incidence was 247 (95%CI: 238-256). Open fractures occurred in 3%, with an incidence of 13 (95%CI: 11-15). Paediatric fractures were more likely to be treated conservatively with only 8% requiring internal fixation, compared to 56% internal fixation in those >or=16 years of age. An increase in the use of angular stable plates occurred during the study period. This prospectively collected study of long-bone fractures in a defined population recognises age- and gender-specific fracture patterns. Boys predominate in the younger age group for which treatment is basically conservative. In the senior population, women and operative treatment predominate.
Gülke, Joachim; Leopold, Barbara; Grözinger, Daniel; Drews, Björn; Paschke, Stephan; Wachter, Nikolaus J
Prospective cohort randomized controlled trial. Is either a home exercise (HE) program or traditional physical therapy (PT) more effective in the postoperative management of metacarpal fractures? Sixty patients suffering from nonthumb metacarpal fractures who received mobilization-stable open reduction and internal fixation were included. All patients were prospectively randomized into either the PT group or the HE group. Follow-up examinations at 2, 6 and 12 weeks postoperatively. After 2 weeks, the range of motion (ROM) in both groups was still severely reduced. Twelve weeks after surgery the ROM improved to 245° (PT) and 256° (HE). Grip strength after 6 weeks was 68% (PT) and 71% (HE) when compared to the non-injured hand, improving to 91% (PT) and 93% (HE) after 12 weeks. Study results show that both HE program and traditional PT are effective in the postoperative management of metacarpal fractures. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.
Scaphocapitate Syndrome With Associated Trans-Scaphoid, Trans-Hamate Perilunate Dislocation
Nunez, Fiesky A.; Luo, T. David; Jupiter, Jesse B.; Nunez, Fiesky A.
2016-01-01
Background: Perilunate fracture dislocations are often associated with fractures of the distal pole of the scaphoid or the proximal pole of the capitate. However, the combination of perilunate dislocation with multiple carpal fractures and associated scaphocapitate syndrome is very rare. Methods: We report a unique case of scaphocapitate fracture syndrome with perilunate dislocation and fracture of the hamate resulting from a high-energy injury to the wrist during a dirt-bike competition. Results: Open reduction and internal fixation of the scaphoid fracture with a 3.0-mm headless screw, the head of the capitate with a 1.5-mm lag screw, and the hamate fracture with a 1.3-mm lag screw was performed. The lunotriquetral dissociation was reduced, with the ligament repaired and the joint stabilized using a Kirschner wire. All screw heads are carefully buried under the articulate cartilage. Conclusions: Prompt anatomic reduction and stable osteosynthesis of all fractures in this patient resulted in successful healing and return to activity. PMID:28344539
Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A
2017-11-15
The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The customized fixation system with topological optimized structure has good biomechanical behavior for mandibular angle fracture because the stress, strain and displacement within the plate could be reduced significantly comparing to conventional "one mini-plate" or "two mini-plates" systems. The design methodology for customized fixation system could be used for other fractures in mandible or other bones to acquire better mechanical behavior of the system and improve stable environment for bone healing. And together with SLM, the customized plate with optimal structure could be designed and fabricated rapidly to satisfy the urgent time requirements for treatment.
Radiographic outcomes of single versus dual plate fixation of acute mid-shaft clavicle fractures.
Chen, Xiaobin; Shannon, Steven F; Torchia, Michael; Schoch, Bradley
2017-06-01
The clavicle exhibits considerable movement in three planes making rigid fixation challenging. The addition of a second plate may be considered to improve fixation rigidity, but risks compromising the blood supply to the fracture site. The purpose of this study is to assess if extraperiosteal dual plate fixation increases the rate of non-union, reoperation, and complications at 1 year for surgically treated acute mid-shaft clavicle fractures. Between June 1998 and June 2013, surgically treated mid-shaft clavicle fractures undergoing open reduction internal fixation within 4 weeks of injury were retrospectively reviewed. Patients undergoing single plate fixation were compared to dual plate fixation. Patients were followed for a minimum of 1 year. Charts were reviewed to assess union rates, reoperation, and complications. One hundred and sixty-three clavicles (125 single plates, 34 dual plates) were evaluated. All patients (100%) in dual plating group and one hundred and fourteen (91%) in single plating group obtained bony union by 1 year (p = 0.13). Six patients (4.8%) experienced a non-union in the single plating cohort compared to the dual plating cohort who had a 100% union rate. Seven patients required reoperation in the single plate cohort due to implant failure (N = 4), infection (N = 2), and non-union (N = 1). This limited series of patients demonstrates dual plate fixation is a reliable option for acute mid-shaft clavicle fractures, with excellent union rates and low complication rates. Compared to single plate fixation, no significant differences in outcomes were identified. In the case of more complex fracture patterns, application of a second extraperiosteal plate may be utilized without compromising healing or increasing complication rates.
Internal quality assurance in a clinical virology laboratory. II. Internal quality control.
Gray, J J; Wreghitt, T G; McKee, T A; McIntyre, P; Roth, C E; Smith, D J; Sutehall, G; Higgins, G; Geraghty, R; Whetstone, R
1995-01-01
AIMS--In April 1991 additional quality control procedures were introduced into the virology section of the Clinical Microbiology and Public Health Laboratory, Cambridge. Internal quality control (IQC) samples were gradually included in the serological assays performed in the laboratory and supplemented kit controls and standard sera. METHODS--From April 1991 to December 1993, 2421 IQC procedures were carried out with reference sera. RESULTS--The IQC samples were evaluated according to the Westgard rules. Violations were recorded in 60 of 1808 (3.3%) controls and were highest in the IQC samples of complement fixation tests (25/312 (8%) of controls submitted for complement fixation tests). CONCLUSIONS--The inclusion of IQC samples in the serological assays performed in the laboratory has highlighted batch to batch variation in commercial assays. The setting of acceptable limits for the IQC samples has increased confidence in the validity of assay results. PMID:7730475
Janson, Jacques T; Rossouw, Gawie J
2013-02-01
An unstable anterior or posterior sternoclavicular joint dislocation can cause severe morbidity with poor shoulder movement and strength. These dislocations need to be repaired, which can be challenging. Many different procedures have been described to obtain a stable joint fixation with varying results. We report a new technique for repairing a sternoclavicular joint dislocation by using a figure-of-eight sternal cable system. This procedure is relatively simple and reproducible to create a stable and functional sternoclavicular joint. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael
2009-09-01
Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.
White, T O; Bugler, K E; Appleton, P; Will, E; McQueen, M M; Court-Brown, C M
2016-09-01
The fundamental concept of open reduction and internal fixation (ORIF) of ankle fractures has not changed appreciably since the 1960s and, whilst widely used, is associated with complications including wound dehiscence and infection, prominent hardware and failure. Closed reduction and intramedullary fixation (CRIF) using a fibular nail, wires or screws is biomechanically stronger, requires minimal incisions, and has low-profile hardware. We hypothesised that fibular nailing in the elderly would have similar functional outcomes to standard fixation, with a reduced rate of wound and hardware problems. A total of 100 patients (25 men, 75 women) over the age of 65 years with unstable ankle fractures were randomised to undergo standard ORIF or fibular nailing (11 men and 39 women in the ORIF group, 14 men and 36 women in the fibular nail group). The mean age was 74 years (65 to 93) and all patients had at least one medical comorbidity. Complications, patient related outcome measures and cost-effectiveness were assessed over 12 months. Significantly fewer wound infections occurred in the fibular nail group (p = 0.002). At one year, there was no evidence of difference in mean functional scores (Olerud and Molander Scores 63; 30 to 85, versus 61; 10 to 35, p = 0.61) or scar satisfaction. The overall cost of treatment in the fibular nail group was £91 less than in the ORIF group despite the higher initial cost of the implant. We conclude that the fibular nail allows accurate reduction and secure fixation of ankle fractures, with a significantly lower rate of soft-tissue complications, and is more cost-effective than ORIF. Cite this article: Bone Joint J 2016;98-B:1248-52. ©2016 The British Editorial Society of Bone & Joint Surgery.
Bonnevialle, P
2017-02-01
Early infection after open reduction and internal fixation (ORIF) of a limb bone is defined as bacteriologically documented, deep and/or superficial surgical-site infection (SSI) diagnosed within 6months after the surgical procedure. This interval is arbitrarily considered sufficient to obtain fracture healing. The treatment of early infection after ORIF should be decided by a multidisciplinary team. The principles are the same as for revision arthroplasty. Superficial SSIs should be differentiated from deep SSIs, based on the results of bacteriological specimens collected using flawless technique. A turning point in the local microbial ecology occurs around the third or fourth week, when a biofilm develops around metallic implants. This biofilm protects the bacteria. The treatment relies on both non-operative and operative measures, which are selected based on the time to occurrence of the infection, condition of the soft tissues, and stage of bone healing. Both the surgical strategy and the antibiotic regimen should be determined during a multidisciplinary discussion. When treating superficial SSIs after ORIF, soft-tissue management is the main challenge. The treatment differs according to whether the hardware is covered or exposed. Defects in the skin and/or fascia can be managed using reliable reconstructive surgery techniques, either immediately or after a brief period of vacuum-assisted closure. In deep SSIs, deciding whether to leave or to remove the hardware is difficult. If the hardware is removed, the fracture site can be stabilised provisionally using either external fixation or a cement rod. Once infection control is achieved, several measures can be taken to stimulate bone healing before the end of the classical 6-month interval. If the hardware was removed, then internal fixation must be performed once the infection is eradicated. Copyright © 2016. Published by Elsevier Masson SAS.
Pan, Xianming; Quan, Yi; Tan, Yingjun; Zhang, Bo; Wang, Yuanshan; Huang, Tong; Ma, Zehui; Liao, Dongfa; Li, Ting; Liu, Jinbiao
2005-03-15
To evaluate the effect of self-designed anti-rotation reduction internal fixator (ARRIF) on treating different spine segment fracture. From August 1999 to March 2003, 76 patients(48 males and 28 females, aged from 22 to 59 with an average of 34.1) with thoracolumbar fracture were operatively treated by ARRIF. The follow-up period ranged from 6 to 21 months (15 months in average). Classification according to injury segment: flexion compression fracture 27 cases, burst fracture 42 cases, flexion distraction injury 3 cases, flexion revolving type fracture dislocation 2 cases, shear force type dislocation 2 cases. Classification according Frankel's grade: A grade 16 cases, B grade 15 cases, C grade 27 cases, D grade 10 cases, E grade 8 cases. Operation duration, volume of bleeding, incidence post-operation complication and effect of reduction-fixation were observed. The operation duration of ARRIF was 1.2 h in average, and there was about 200 ml volume of bleeding during operation. The nerve function showed one Frankel's grade improvement after operation were as follows: A grade 8 cases (50%), B grade 11 cases (73.3%), C grade 20 cases (74.1%), D grade 3 cases (30%); 2 Frankel's E cases have no nerve function changes. The nerve function damage have no aggravation in all the patients, the postoperation Cobb's angle was averagely corrected 22 degrees. The horizontal displacement of dislocation vertebrae was averagely corrected 28% in sagittal plane, the statistical analysis had significant variance (P < 0.01). ARRIF had no complications of the breakage of screws and rods. ARRIF proves to be a valid internal fixator in reducing and fixing different thoracic lumbar segment spine fracture.
Miao, De-chao; Zhang, Bao-yang; Lei, Tao; Shen, Yong
2017-01-01
Background The aim of this study was to analyze the clinical features and to evaluate the efficacy of anterior partial corpectomy and titanium mesh fusion and internal fixation of old fracture dislocation of the lower cervical spine. Material/Methods We retrospectively analyzed the clinical data of 52 patients with old lower cervical fracture and dislocation treated with anterior partial corpectomy and titanium mesh fusion fixation between January 2008 and December 2013, with a mean follow-up period of 4.1 years. There were 35 males and 17 females. Patient radiological data and clinical parameters were recorded and compared before and after the operations. Results The average follow-up was 4.1 years. Intervertebral height and physiological curvature were well-reconstructed for all cases. No loosening or rupturing of titanium plate or screw occurred. The neurological function of the patients with incomplete spinal cord injury was significantly improved, and the function of the nerve roots at the injury level was also improved in patients with complete spinal cord injury. Bone fusion was completed within 6 months to 1 year after surgery. Conclusions Completed decompression, sequence and physiological curvature of the cervical vertebra, immediate and long-term anterior cervical column support, and nerve function restoration can be achieved by using anterior partial corpectomy and titanium mesh fusion and internal fixation to treat old fracture dislocation of the lower cervical spine. For cases with locked facet joints or posterior structures invading the vertebral canal, the combined anterior and posterior approaches should be performed, when necessary, to achieve better results. PMID:29184051
Treatment of type II odontoid fracture with a novel technique
Zhu, Ce; Wang, Lei; Liu, Hao; Song, Yueming; Liu, Limin; Li, Tao; Gong, Quan
2017-01-01
Abstract Surgical methods for type II odontoid fracture can be classified into 2 main groups: anterior or posterior approach. A more effective way to achieve bone fusion with the lowest possible surgical risk is needed. Therefore, the aim of our study was to describe and evaluate a novel technique, cable-dragged reduction/cantilever beam internal fixation for the treatment of type II odontoid fracture. This was a retrospective study enrolled 34 patients underwent posterior cable-dragged reduction/cantilever-beam internal fixation surgery. Medical records, rates of reduction, the location of the instrumentation and fracture healing during follow-up were analyzed. Once fracture healing was obtained, instrumentation was removed. Neck pain (scored using a visual analog scale [VAS]), neck stiffness, patient satisfaction, and neck disability index (NDI) were recorded before and after removing the instrumentation during follow-up. The mean duration of follow up was 22.8 ± 5.3 months. There was no iatrogenic damage to nerves or blood vessels. Radiographic evaluation showed complete reduction in the 20 patients with fracture displacement and satisfactory fracture healing in all 34 cases. Titanium cable breakage was observed in 4 patients after fracture healing. After removal of instrumentation, significant improvements were seen in neck-pain VAS score, neck stiffness, patient satisfaction, and NDI (all P < .01). Posterior cable-dragged reduction/cantilever-beam internal fixation was an optimal salvage maneuver to conventional surgical methods such as anterior screw fixation and C1–C2 screw-rod system. The operative difficulty and incidence of nerve and vascular injury were reduced. Its major disadvantage is the exposure and screw-setting at C3, which is left intact in traditional surgery, and it is suitable only for patients with intact C1 posterior arches. PMID:29095313
Surgical treatment of open pilon fractures.
Zeng, Xian-tie; Pang, Gui-gen; Ma, Bao-tong; Mei, Xiao-long; Sun, Xiang; Wang, Jia; Jia, Peng
2011-02-01
To discuss the methods, timing and clinical outcomes of surgical treatment for open pilon fractures. From April 2003 to July 2008, 28 patients with open pilon fractures were treated. All had type C fractures according to the Arbeitsgemeinschaft für osteosynthesefragen-Association for the Study of Internal Fixation (AO/ASIF) classification. Three operative methods were applied, the methods being determined by the types of fracture, soft tissue damage and time interval after injury. Seven cases were treated by debridement and internal fixation with plate; 19 by limited internal fixation combined with external fixation; and 2 by delayed surgery. The clinical outcomes were evaluated by the Burwell-Charnley score. All cases were followed up for from 6 to 48 months (average 24 months). The Burwell-Charnley score of clinical outcomes: anatomic reduction achieved in 12 cases, functional reduction in 15, and unsatisfactory reduction in 1. The healing time was from 2.5 to 11 months (average 4.7 months). Two cases had delayed union. According to the American Orthopaedic Foot and Ankle Society (AOFAS) scale for the ankle joint, there were excellent results in 8 cases, good in 14, fair in 5 and poor in 1. Complications included four cases of skin superficial sloughing, two of superficial infection, one of deep infection, two of delayed fracture union and ten of post-traumatic arthritis. It is important to perform appropriate surgeries for open pilon fracture according to fracture classification, different damage to skin and tissue and time interval after injury. Thorough debridement, proper use of anti-infective medication, appropriate bone grafting, and postoperative ankle function exercise can reduce the occurrence of complications. © 2011 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
Wrist Arthrodesis for Failed Total Wrist Arthroplasty.
Adams, Brian D; Kleinhenz, Ben P; Guan, Justin J
2016-06-01
Treatment options for failed total wrist arthroplasty include implant revision, resection arthroplasty, and arthrodesis. Variable results associated with different techniques have been reported for arthrodesis and the procedure has substantial technical challenges, including restoration of wrist height, obtaining stable fixation, and achieving bony fusion. This study evaluates the radiographic results of a surgical technique for conversion of a failed arthroplasty to an arthrodesis. A retrospective chart and radiograph review was performed in 20 wrists in 18 patients in whom conversion to an arthrodesis was performed using a contoured cancellous femoral head structural allograft and a wrist arthrodesis plate. Supplemental demineralized bone matrix combined with corticocancellous allograft chips was also used in 15 wrists. Median age at arthrodesis was 61 years (range, 45-78 years), and median follow-up was 34 months (range, 4-71 months). Nineteen of 20 wrists fused following the index procedure at a median of 4 months (range, 3-7 months). Proximal plate loosening occurred in 1 wrist but the joint still fused at 6 months; a successful osteotomy and revision of screw fixation was done 2 years later to correct the deformity and hardware irritation in this case. Complications were otherwise limited to 1 superficial infection that resolved with intravenous antibiotics. This technique for conversion of a failed total wrist arthroplasty to a wrist arthrodesis is safe, effective, and versatile. Wrist deformity is corrected, wrist height can be restored, stable fixation is obtained, and a high rate of fusion is achieved despite filling large defects using structural cancellous allograft. Therapeutic IV. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
[Clinical practice guideline on closed tibial plateau fractures in adulthood].
Ocegueda-Sosa, Miguel Ángel; Valenzuela-Flores, Adriana Abigail; Aldaco-García, Víctor Daniel; Flores-Aguilar, Sergio; Manilla-Lezama, Nicolás; Pérez-Hernández, Jorge
2013-01-01
Closed tibiae plateau fractures are common injuries in the emergency room. The optimal treatment is not well defined or established. For this reason, there are several surgical management options: open reduction and internal fixation, closed reduction and percutaneous synthesis, external fixation, and even conservative treatment for this kind of fracture. The mechanism of production of this fracture is through large varus or valgus deformation to which is added a factor of axial load. The trauma may be direct or indirect. The degree of displacement, fragmentation and involvement of soft tissues like ligaments, menisci, vascular and nerve structures are determined by the magnitude of the force exerted. Any intra-articular fracture treatment can lead to an erroneous instability, deformity and limitation of motion with subsequent arthritic changes, leading to joint incongruity, limiting activity and significantly altering the quality of life. Open reduction and internal fixation with anatomic restitution is the method used in this type of fracture. However, the results of numerous publications can be questioned due to the inclusion in the same study of fractures treated with very different methods.
Watrous, Gwyneth K; Moens, Noel M M
2017-04-01
This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg.
[Treatment of acromion base fractures with double plates internal fixation].
Lü, Guo-Qiang; Zhu, Jun-Kun; Lan, Shu-Hua; Wu, Quan-Zhou; Zheng, Rong-Zong; Zheng, Chong-Wu
2013-09-01
To study clinical effects of double plates fixation for the treatment of acromion base fracutres. From January 2010 to May 2012, 7 patients with acromion base fractures were treated with double plates ORIF surgical treatment. There were 5 males and 2 females, with an average age of 36.3 years old (ranged, 24 to 62 years old). All fractures were acuted and closed injuries. The duration from injury to surgery was 4.6 days (ranged, 2 to 10 days). Hardegger functional criterion, Visual Analogue Scale (VAS) and complications of the patients were documented analysis. All the patients were followed up,and the duration ranged from 4 to 13 months (averaged 8.9 months). The healing duration of fractures ranged from 8 to 14 weeks without any infection, shoulder instability, subacromial impingement syndrome, nonunion and failure of internal fixation. At the latest follow-up, the VAS ranged from 0 to 5. According to Hardegger criterion, 2 patients got an excellent result, 4 good and 1 poor. Double plates ORIF plays a positive role in the treatment of acromion base fractures, which reduces complications and maximally restore the function of shoulder.
Watrous, Gwyneth K.; Moens, Noel M.M.
2017-01-01
This retrospective study evaluated complication rates for radius and ulna fractures in small breed dogs in which 1.5 mm to 2.7 mm cuttable bone plates were used for internal fixation. The medical records of all cases from 2004 to 2011 that were presented to our clinic were reviewed. Inclusion criteria were: dogs with body weight < 9 kg, fracture of the radius and ulna with open reduction, and internal fixation utilizing a cuttable bone plate. Thirty-four fractures in 31 dogs met the inclusion criteria. Of 25 dogs that were available for follow-up, all achieved union, minor complications occurred in 9, and major complications occurred in 8. External coaptation was responsible for complications in 8 cases and the need for coaptation needs to be investigated. Excluding minor complications, 32% of patients required at least 1 additional surgery or additional hospitalization. All but 2 of the dogs returned to full function. The 1.5 mm straight plate was successfully used in all dogs with a body weight of 0.9 to 2.6 kg. PMID:28373730
A Retrospective Case Series of Carbon Fiber Plate Fixation of Ankle Fractures.
Pinter, Zachariah W; Smith, Kenneth S; Hudson, Parke W; Jones, Caleb W; Hadden, Ryan; Elattar, Osama; Shah, Ashish
2018-06-01
Distal fibula fractures represent a common problem in orthopaedics. When fibula fractures require operative fixation, implants are typically made from stainless steel or titanium alloys. Carbon fiber implants have been used elsewhere in orthopaedics for years, and their advantages include a modulus of elasticity similar to that of bone, biocompatibility, increased fatigue strength, and radiolucency. This study hypothesized that carbon fiber plates would provide similar outcomes for ankle fracture fixation as titanium and steel implants. A retrospective chart review was performed of 30 patients who underwent fibular open reduction and internal fixation (ORIF). The main outcomes assessed were postoperative union rate and complication rate. The nonunion or failure rate for carbon fiber plates was 4% (1/24), and the union rate was 96% (23/24). The mean follow-up time was 20 months, and the complication rate was 8% (2/24). Carbon fiber plates are a viable alternative to metal plates in ankle fracture fixation, demonstrating union and complication rates comparable to those of traditional fixation techniques. Their theoretical advantages and similar cost make them an attractive implant choice for ORIF of the fibula. However, further studies are needed for extended follow-up and inclusion of larger patient cohorts. Level IV: Retrospective Case series.
External fixation of "intertrochanteric" fractures.
Gani, Naseem Ul; Kangoo, Khursheed Ahmed; Bashir, Arshad; Muzaffer, Rahil; Bhat, Mohammad Farooq; Farooq, Munir; Badoo, Abdul Rashid; Dar, Imtiyaz Hussian; Wani, Mudassir Maqbool
2009-10-10
In developing countries, due to limited availability of modern anesthesia and overcrowding of the hospitals with patients who need surgery, high-risk patients with "intertrochanteric" fractures remain unsuita ble for open reduction and internal fixation.The aim of this study was to analyze the results of external fixation of "intertrochanteric" fractures in high-risk geriatric patients in a developing country.The results of 62 ambulatory high-risk geriatric patients with a mean age of 70 years (range 58-90 years) with "intertrochanteric" fractures, in whom external fixation was performed, are reported.Eight patients died during follow-up due to medical causes unrelated to the surgical procedure. So only 54 patients were available for final assessment. Procedure is simple, performed under local anesthesia, requires less time for surgery and is associated with less blood loss. Good fixation and early ambulation was achieved in most of the patients. Average time to union was 14 weeks. Thirty-one patients developed superficial pin tract infection and 28 patients had average shortening of 15 mm due to impaction and varus angulation. Functional outcome was assessed using Judet's point system. Good to excellent results were achieved in 44 patients.This study demonstrated that external fixation of "intertrochantric" fractures performed under local anesthesia offers significant advantage in ambulatory high-risk geriatric patients especially in a developing country.
A Biomechanical Comparison of Distal Fixation for Bridge Plating in a Distal Radius Fracture Model.
Alluri, Ram K; Bougioukli, Sofia; Stevanovic, Milan; Ghiassi, Alidad
2017-09-01
To compare the biomechanical properties of second versus third metacarpal distal fixation when using a radiocarpal spanning distraction plate in an unstable distal radius fracture model. Biomechanical evaluation of the radiocarpal spanning distraction plate comparing second versus third metacarpal distal fixation was performed using a standardized model of an unstable wrist fracture in 10 matched-pair cadaveric specimens. Each fixation construct underwent a controlled cyclic loading protocol in flexion and extension. The resultant displacement and stiffness were calculated at the fracture site. After cyclic loading, each specimen was loaded to failure. The stiffness, maximum displacement, and load to failure were compared between the 2 groups. Cyclic loading in flexion demonstrated that distal fixation to the third metacarpal resulted in greater stiffness compared with the second metacarpal. There was no significant difference between the 2 groups with regards to maximum displacement at the fracture site in flexion. Cyclic loading in extension demonstrated no significant difference in stiffness or maximum displacement between the 2 groups. The average load to failure was similar for both groups. Fixation to the third metacarpal resulted in greater stiffness in flexion. All other biomechanical parameters were similar when comparing distal fixation to the second or third metacarpal in distal radius fractures stabilized with a spanning internal distraction plate. The treating surgeon should choose distal metacarpal fixation primarily based on fracture pattern, alignment, and soft tissue integrity. If a stiffer construct is desired, placement of the radiocarpal spanning plate at the third metacarpal is preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Thomson, Callum M; Esparon, Tom; Rea, Paul M; Jamal, Bilal
2016-10-01
The use of external fixation for intra-articular calcaneal fractures is increasing in popularity. Studies have shown fine wire and monoaxial external fixation to be a viable surgical alternative to more invasive methods of open reduction and internal fixation of the calcaneus. However, there is an absence of literature that quantifies the risk of pin insertion for monoaxial fixation. This study aimed to determine the safety of inserting monoaxial pins within the calcaneus to house the Orthofix Calcaneal Mini-Fixator. Five formalin embalmed cadaveric ankle and lower leg specimens were inserted with six monoaxial pins. Careful dissection then revealed the presence of the tendons of peroneus longus and brevis, the sural nerve and the small saphenous vein in relation to these pins. Measurements from each pin to each of these structures were made as the structures transected lines drawn from each pin to two palpable bony landmarks: the inferior tip of the lateral malleolus and the posterosuperior calcaneus. In doing this, the risk posed by each pin could be evaluated. We found that two particular pins, those used to hold the articular surface of the subtalar joint in a reduced position, posed a larger risk of injury to surrounding structures than the remaining pins. These findings therefore suggest that monoaxial fixation of the calcaneus using a six pin approach is a relatively safe method of rectifying calcaneal fractures and thus may serve as a welcome alternative to other methods of calcaneal fixation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Madsen, Wes; Yaseen, Zaneb; LaFrance, Russell; Chen, Tony; Awad, Hani; Maloney, Michael; Voloshin, Ilya
2013-06-01
The purpose of this study was to determine the effect of coracoclavicular (CC) fixation on biomechanical stability in type IIB distal clavicle fractures fixed with plate and screws. Twelve fresh-frozen matched cadaveric specimens were used to create type IIB distal clavicle fractures. Dual-energy x-ray absorptiometry (DEXA) scans ensured similar bone quality. Group 1 (6 specimens) was stabilized with a superior precontoured distal clavicle locking plate and supplemental suture anchor CC fixation. Group 2 (6 specimens) followed the same construct without CC fixation. Each specimen was cyclically loaded in the coronal plane at 40 to 80 N for 17,500 cycles. Load-to-failure testing was performed on the specimens that did not fail cyclic loading. Outcome measures included mode of failure and the number of cycles or load required to create 10 mm of displacement in the construct. All specimens (12 of 12) completed cyclic testing without failure and underwent load-to-failure testing. Group 1 specimens failed at a mean of 808.5 N (range, 635.4 to 952.3 N), whereas group 2 specimens failed at a mean of 401.3 N (range, 283.6 to 656.0 N) (P = .005). Group 1 specimens failed by anchor pullout without coracoid fracture (4 of 6) and distal clavicle fracture fragment fragmentation (1 of 6); one specimen did not fail at the maximal load the materials testing machine was capable of exerting (1,000 N). Group 2 specimens failed by distal clavicle fracture fragment fragmentation (3 of 6) and acromioclavicular (AC) joint displacement (1 of 6); 2 specimens did not fail at the maximal load of the materials testing machine. During cyclic loading, type IIB distal clavicle fractures with and without CC fixation remain stable. CC fixation adds stability to type IIB distal clavicle fractures fixed with plate and screws when loaded to failure. CC fixation for distal clavicle fractures is a useful adjunct to plate-and-screw fixation to augment stability of the fracture. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Faucett, Scott C; Genuario, James W; Tosteson, Anna N A; Koval, Kenneth J
2010-02-01
: A previous hip fracture more than doubles the risk of a contralateral hip fracture. Pharmacologic and environmental interventions to prevent hip fracture have documented poor compliance. The purpose of this study was to examine the cost-effectiveness of prophylactic fixation of the uninjured hip to prevent contralateral hip fracture. : A Markov state-transition model was used to evaluate the cost and quality-adjusted life-years (QALYs) for unilateral fixation of hip fracture alone (including internal fixation or arthroplasty) compared with unilateral fixation and contralateral prophylactic hip fixation performed at the time of hip fracture or unilateral fixation and bilateral hip pad protection. Prophylactic fixation involved placement of a cephalomedullary nail in the uninjured hip and was initially assumed to have a relative risk of a contralateral fracture of 1%. Health states included good health, surgery-related complications requiring a second operation (infection, osteonecrosis, nonunion, and malunion), fracture of the uninjured hip, and death. The primary outcome measure was the incremental cost-effectiveness ratio estimated as cost per QALY gained in 2006 US dollars with incremental cost-effectiveness ratios below $50,000 per QALY gained considered cost-effective. Sensitivity analyses evaluated the impact of patient age, annual mortality and complication rates, intervention effectiveness, utilities, and costs on the value of prophylactic fixation. : In the baseline analysis, in a 79-year-old woman, prophylactic fixation was not found to be cost-effective (incremental cost-effectiveness ratio = $142,795/QALY). However, prophylactic fixation was found to be a cost-effective method to prevent contralateral hip fracture in: 1) women 71 to 75 years old who had 30% greater relative risk for a contralateral fracture; and 2) women younger than age 70 years. Cost-effectiveness was greater when the additional costs of prophylaxis were less than $6000. However, for most analyses, the success of prophylactic fixation was highly sensitive to the effectiveness and the relative morbidity and mortality of the additional procedure. : Prophylactic fixation with a cephalomedullary nail was not found to be cost-effective for the average older woman who sustained a hip fracture. However, it may be appropriate for select patient populations. The study supports the need for basic science and clinical trials investigating the effectiveness of prophylactic fixation for patient populations at higher lifetime risk for contralateral hip fracture.
Moro, Alessandro; Todaro, Mattia; Pedicelli, Alessandro; Alexandre, Andrea; Pelo, Sandro; Doneddu, Piero; Gasparini, Giulio; Garagiola, Umberto; D'Amato, Giuseppe; Saponaro, Gianmarco
2018-04-01
Pseudoaneurysms are an uncommon complication of mandibular condylar-subcondylar fractures; however, if present, their recognition and management is mandatory to avoid life-threatening situations. The authors report a case of internal maxillary artery pseudoaneurysm rupture that occurred after an open reduction and internal fixation of a mandibular subcondylar fracture, along with a review of the literature.
Hicks, Daniel G; Pitts, Marvin J; Bagley, Rodney S; Vasavada, Anita; Chen, Annie V; Wininger, Fred A; Simon, Julianna C
2009-06-01
To determine the change in stiffness as evaluated by the dorsal bending moment of cervical vertebral specimens obtained from canine cadavers after internally stabilizing the vertebral motion unit (VMU) of C4 and C5 with a traditional pin-polymethylmethacrylate (PMMA) fixation implant or a novel screw-bar-PMMA fixation implant. 12 vertebral column specimens (C3 through C6) obtained from canine cadavers. A dorsal bending moment was applied to the vertebral specimens before and after fixation of the VMU of C4 and C5 by use of a traditional pin-PMMA implant or a novel screw-bar-PMMA implant. Biomechanical data were collected and compared within a specimen (unaltered vs treated) and between treatment groups. Additionally, implant placement was evaluated after biomechanical testing to screen for penetration of the transverse foramen or vertebral canal by the pins or screws. Treated vertebral specimens were significantly stiffer than unaltered specimens. There was no significant difference in stiffness between vertebral specimen groups after treatment. None of the screws in the novel screw-bar-PMMA implant group penetrated the transverse foramen or vertebral canal, whereas there was mild to severe penetration for 22 of 24 (92%) pins in the traditional pin-PMMA implant group. Both fixation treatments altered the biomechanical properties of the cervical vertebral specimens as evaluated by the dorsal bending moment. There was reduced incidence of penetration of the transverse foramen or vertebral canal with the novel screw-bar-PMMA implant, compared with the incidence for the traditional pin-PMMA implant.
Pain as an indication for rib fixation: a bi-institutional pilot study.
de Moya, Marc; Bramos, Thanos; Agarwal, Suresh; Fikry, Karim; Janjua, Sumbal; King, David R; Alam, Hasan B; Velmahos, George C; Burke, Peter; Tobler, William
2011-12-01
In trauma patients, open reduction and internal fixation of rib fractures remain controversial. We hypothesized that patients who have open reduction and internal fixation of rib fractures would experience less pain compared with controls and thus require fewer opiates. Further, we hypothesized that improved pain control would result in fewer pulmonary complications and decreased length of stay. This is a retrospective bi-institutional matched case-control study. Cases were matched 1:2 by age, injury severity Score, chest abbreviated injury severity score, head abbreviated injury severity score, pulmonary contusion score, and number of fractured ribs. The daily total doses of analgesic drugs were converted to equianalgesic intravenous morphine doses, and the primary outcome was inpatient narcotic administration. Sixteen patients between July 2005 and June 2009 underwent rib fixation in 5 ± 3 days after injury using an average of 3 (1-5) metallic plates. Morphine requirements decreased from 110 mg ± 98 mg preoperatively to 63 ± 57 mg postoperatively (p = 0.01). There were no significant differences between cases and controls in the mean morphine dose (79 ± 63 vs. 76 ± 55 mg, p = 0.65), hospital stay (18 ± 12 vs. 16 ± 11 days, p = 0.67), intensive care unit stay (9 ± 8 vs. 7 ± 10 days, p = 0.75), ventilation days (7 ± 8 vs. 6 ± 10, p = 0.44), and pneumonia rates (31% vs. 38%, p = 0.76). The need for analgesia was significantly reduced after rib fixation in patients with multiple rib fractures. However, no difference in outcomes was observed when these patients were compared with matched controls in this pilot study. Further study is required to investigate these preliminary findings.
Reichel, Lee M; MacCormick, Lauren M; Dugarte, Anthony J; Rizkala, Amir R; Graves, Sara C; Cole, Peter A
2018-02-01
Anterior external fixation for pelvic ring fractures has shown to effectively improve stability and reduce mortality. However, these fixators can be associated with substantial morbidity such as pin tract infection, premature loss of fixation, and decreased quality of life in patients. Recently, two new methods of subcutaneous anterior pelvic internal fixation have been developed; the INFIX and the Pelvic Bridge. These methods have the purported advantages of lower wound complications, less surgical site pain, and improved quality of life. We sought to investigate the measured distances to critical anatomic structures, as well as the qualitative and topographic differences notable during implantation of both devices in the same cadaveric specimen. The Pelvic Bridge and INFIX were implanted in eleven fresh cadavers. Distances were then measured to: the superficial inguinal ring, round ligament, spermatic cord, lateral femoral cutaneous nerve (LFCN), femoral nerve, femoral artery, and femoral vein. Observations regarding implantation and topography were also recorded. The INFIX had greater measured distances from all structures except for the LFCN, in which its proximity placed this structure at risk. Neither device appears to put other critical structures at risk in the supine position. Significant implantation and topographic differences exist between the devices. The INFIX application lacked "safety margins" concerning the LFCN in 10/11 (90.9%) specimens, while Pelvic Bridge placement lacked "safety margins" with regard to the right superficial ring (1/11, 9%) and the right spermatic cord (1/11, 9%). Both the Pelvic Bridge and INFIX lie at safe distances from most critical pelvic structures in the supine position, though INFIX application places the LFCN at risk. Copyright © 2017 Elsevier Ltd. All rights reserved.
Use of monocortical miniplates for the intraoral treatment of mandibular fractures.
Chiodo, Thomas A; Milles, Maano
2009-03-01
Fixation of mandibular fractures using rigid hardware has gained wide acceptance over the past 3 decades. The goal of rigid internal fixation is to allow for fracture healing with limited, or no, time in maxillo-mandibular fixation. There has been significant evolution in plate and screw materials and design over the past 30 years. The term miniplate is used to describe a fracture plate with a screw diameter of 2.0 mm or less. With correct diagnosis and understanding of the forces affecting mandible fractures, miniplates can be applied transorally in various situations, allowing for less invasive treatment with open reduction of mandible fractures. This article describes the use of monocortical miniplates for the intraoral treatment of mandibular fractures.
Technical considerations for surgical intervention of Jones fractures.
Mendicino, Robert W; Hentges, Matthew J; Mendicino, Michael R; Catanzariti, Alan R
2013-01-01
Jones fractures are a common injury treated by foot and ankle surgeons. Surgical intervention is recommended because of the high rate of delayed union, nonunion, and repeat fracture, when treated conservatively. Percutaneous intramedullary screw fixation is commonly used in the treatment of these fractures. We present techniques that can increase the surgical efficiency and decrease the complications associated with percutaneous delivery of internal fixation. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Zhang, Zhi-Da; Ye, Xiu-Yi; Shang, Li-Yong; Xu, Rong-Ming; Zhu, Yan-Zhao
2011-12-01
To explore the clinical efficacy of delayed open reduction and internal fixation with minimally invasive percutaneous locking compression plate for the treatment of type II and III Pilon fractures. From January 2007 to September 2009, 32 patients with type II and III Pilon fractures were treated with open reduction and anatomic plate fixation (AP group) and minimally invasive percutaneous locking compression plate osteosynthesis (LCP group). There were 11 males and 6 females in AP group, with an average age of (37.4 +/- 13.3) years (ranged, 19 to 55 years). And there were 10 males and 5 females in LCP group, with an average age of (34.6 +/- 11.3) years(ranged, 21 to 56 years). The operating time, fracture healing time, aligned angulation and ankle function were compared between the two groups. All the patients were followed up, and the during ranged from 12 to 25 months, with a mean of (15.0 +/- 1.7) months. The average operation time was (76.5 +/- 8.3) min for AP group and (58.3 +/- 3.4) min for LCP group; the average time of fracture healing was (20.5 +/- 0.4) weeks for AP group and (15.7 +/- 0.2) weeks for LCP group; the total angulation between anterior posterior film and lateral film was averaged (6.6 +/- 0.5) degrees for AP group and (3.6 +/- 0.2) degrees for LCP group. As to above index, the results of LCP group were better than those of AP group (P < 0.05). According to Kofoed criteria for ankle joint, the results of LCP group were better than those of AP group in ankle joint pain, wakling and ankle joint function (P < 0.05). The method of minimally invasive percutaneous locking compression plate internal fixation is effective in the treatment of Pilon fracture with less invasion, faster bone union, more stabilized fixation, quicker recovery of ankle function and fewer complications, which is more advantaged for type II and III Pilon fractures.
Evolutionary dynamics of fluctuating populations with strong mutualism
NASA Astrophysics Data System (ADS)
Chotibut, Thiparat; Nelson, David
2013-03-01
Evolutionary game theory with finite interacting populations is receiving increased attention, including subtle phenomena associated with number fluctuations, i.e., ``genetic drift.'' Models of cooperation and competition often utilize a simplified Moran model, with a strictly fixed total population size. We explore a more general evolutionary model with independent fluctuations in the numbers of two distinct species, in a regime characterized by ``strong mutualism.'' The model has two absorbing states, each corresponding to fixation of one of the two species, and allows exploration of the interplay between growth, competition, and mutualism. When mutualism is favored, number fluctuations eventually drive the system away from a stable fixed point, characterized by cooperation, to one of the absorbing states. Well-mixed populations will thus be taken over by a single species in a finite time, despite the bias towards cooperation. We calculate both the fixation probability and the mean fixation time as a function of the initial conditions and carrying capacities in the strong mutualism regime, using the method of matched asymptotic expansions. Our results are compared to computer simulations.
O'Shaughnessy, Maureen A.; Shin, Alexander Y.; Kakar, Sanjeev
2016-01-01
Background Distal radius fractures involving the lunate facet can be challenging to manage. Reports have shown the volar carpal subluxation/dislocation that can occur if the facet is not appropriately stabilized. Literature Review Recent emphasis in the literature has underscored the difficulty in managing this fracture fragment, suggesting standard volar plates may not be able to adequately stabilize the fragment. This article reviews the current literature with a special emphasis on fixation with a specifically designed fragment-specific hook plate to secure the lunate facet. Case Description An extended flexor carpi radialis volar approach was made which allows access to the distal volar ulnar fracture fragment. Once provisionally stabilized with Kirschner wire fixation, a volar hook plate was applied to capture this fragment. Additional fracture stabilization was used as deemed necessary to stabilize the remaining distal radius fracture. Clinical Relevance The volar marginal rim fragment remains a challenge in distal radius fracture management. Use of a hook plate to address the volar ulnar corner allows for stable fixation without loss of reduction at intermediate-term follow-up. PMID:27104076
Late Complications of Chest Wall Reconstruction: Management of Painful Sternal Nonunion
Chepla, Kyle J.; Salgado, Christopher J.; Tang, Cathy J.; Mardini, Samir; Evans, Karen K.
2011-01-01
Although rare, sternal nonunion after median sternotomy or traumatic injury is associated with a high rate of morbidity. Pain and sternal clicking are two of the most common complaints and reasons these patients seek evaluation and treatment. Diagnosis of sternal nonunion is based on a thorough history and physical examination and can be confirmed with subsequent radiographic imaging. The treatment for symptomatic sternal nonunion requires stable fixation of the bony fragments and chest wall after the debridement of all nonviable bony and soft tissue by the cardiothoracic or reconstructive surgery team. Multiple fixation techniques have been described and incorporate a wide variety of materials including combinations of wires, cables, pins, bands, staples, and plates. Most recently, several new commercially available plating systems have demonstrated low recurrence and complication rates and resolution of the patient's symptoms on follow-up evaluation. Included in this review are three cases demonstrating the management of symptomatic sternal nonunion using these new techniques and review the history, diagnosis, risk factor, and classification, as well as several of the previously described fixation methods. PMID:22294948
Zhang, Jianlin; Tan, Yu'e; Ye, Jun; Han, Fangmin
2012-02-01
To explore the effectiveness of bone grafting by intervertebral disc endoscope for postoperative nonunion of fracture of lower limb. Between August 2004 and August 2008, 40 patients (23 males and 17 females) with postoperative nonunion of femoral and tibial fracture, aged 20-63 years (mean, 41.5 years) were treated. Nonunion of fracture occurred at 10-16 months after internal fixation. During the first operation, the internal fixation included interlocking intramedullary nailing of femoral fracture in 12 cases and plate in 16 cases, and interlocking intramedullary nailing of tibial fractures in 9 cases and plate in 3 cases. The X-ray films showed hypertrophic nonunion in 24 cases, common nonunion in 3 cases, and atrophic nonunion in 13 cases. The average operation time was 61 minutes (range, 40-80 minutes), and the blood loss was 80-130 mL (mean, 100 mL). The hospitalization time were 6-11 days (mean, 8.1 days). Incisions healed by first intention in all patients with no complication of infection or neurovascular injury. Forty patients were followed up 10-16 months (mean, 12.3 months). The X-ray films showed that all patients achieved healing of fracture after 4-10 months (mean, 6.8 months). No pain, disfunction, or internal fixation failure occurred. Bone grafting by intervertebral disc endoscope is an effective method for treating postoperative nonunion of femoral and tibial fracture.
Razii, Nima; Abbas, Ammar M I; Kakar, Rahul; Agarwal, Sanjeev; Morgan-Jones, Rhidian
2016-12-01
Periprosthetic infection following total knee arthroplasty is a devastating complication, which is not always satisfactorily resolved by revision surgery. Arthrodesis is a salvage alternative to above-knee amputation or permanent resection arthroplasty. Fixation options include internal compression plating, external fixation, and intramedullary nails. We retrospectively reviewed twelve consecutive cases (9 males, 3 females; mean age, 67 years) of knee arthrodesis with a long intramedullary nail, performed at a single institution between 2003 and 2014. Desired outcomes were the ability to mobilize without pain, solid radiographic fusion, and the eradication of infection. Mean follow-up was 48.5 months (range, 9-120 months). Eleven patients (92 %) demonstrated stable fusion, ten patients (83 %) were ambulatory without pain, and ten patients (83 %) remained without infection at most recent follow-up. Eight patients (67 %) achieved union at an average of 12 months; three required repeat procedures, achieving union at an average of 9 months. There was a significant difference (P < 0.01) between the numbers of previous operations amongst the eight patients who initially achieved union (mean, 3.25) and three who subsequently required repeat procedures (mean, 8.33). In contrast to similar studies, we performed a single-stage exchange where possible, while comparable ambulatory and fusion rates were observed. Numerous previous attempts at revision arthroplasty, co-morbidities, and infections with highly resistant organisms have been associated with further complications. Although technically challenging, knee arthrodesis with a long intramedullary nail offers an acceptable limb salvage procedure for carefully selected patients with complex periprosthetic infections.
Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures
Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed
2014-01-01
This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact. PMID:26269728
Intra-articular fractures of the distal tibia
Sitnik, Alexandre; Beletsky, Aleksander; Schelkun, Steven
2017-01-01
Results of the treatment of intra-articular fractures of the distal tibia have improved significantly during the last two decades. Recognition of the role of soft tissues has led to the development of a staged treatment strategy. At the first stage, joint-bridging external fixation and fibular fixation are performed. This leads to partial reduction of the distal tibial fracture and allows time for the healing of soft tissues and detailed surgical planning. Definitive open reduction and internal fixation of the tibial fracture is performed at a second stage, when the condition of the soft tissues is safe. The preferred surgical approach(es) is chosen based on the fracture morphology as determined from standard radiographic views and computed tomography. Meticulous atraumatic soft-tissue handling and the use of modern fixation techniques for the metaphyseal component such as minimally invasive plate osteosynthesis further facilitate healing. Cite this article: EFORT Open Rev 2017;2:352-361. DOI: 10.1302/2058-5241.2.150047 PMID:28932487
Nitrogen fixation in a non-heterocystous cyanobacterial mat from a mountain river
NASA Astrophysics Data System (ADS)
Berrendero, Esther; Valiente, Eduardo Fernández; Perona, Elvira; Gómez, Claudia L.; Loza, Virginia; Muñoz-Martín, M. Ángeles; Mateo, Pilar
2016-08-01
In situ nitrogen fixation was investigated in a cyanobacterial mat growing on the bed of rocks of the Muga River, Spain. The filamentous non-heterocystous cyanobacterium Schizothrix dominated the mat, showing nitrogenase activity in the light at similar rates to those found in nearby heterocystous Rivularia colonies. N2 fixation in the light was significantly increased by an inhibitor of PSII and oxygen evolution, DCMU (3-[3,4-dichlorophenyl]-1,1-dimethylurea), and anaerobic conditions. However, no nitrogenase activity was found in the dark. Addition of fructose as a respiratory substrate induced nitrogenase activity in samples incubated under aerobic conditions in the dark but not in anaerobic conditions. Microelectrode oxygen profiles showed internal microaerobic microzones where nitrogen fixation might concentrate. Analyses of the 16S rRNA gene revealed only the presence of sequences belonging to filamentous non-heterocystous cyanobacteria. nifH gene diversity showed that the major phylotypes also belonged to this group. One of the three strains isolated from the Schizothrix mat was capable of fixing N2 and growing in the absence of combined N. This was consistent with the nifH gene analysis. These results suggest a relevant contribution of non-heterocystous cyanobacteria to nitrogen fixation in these mats.
Operative fixation of chest wall fractures: an underused procedure?
Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David
2007-06-01
Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.
Jo, Jae-Young; Yang, Dong-Seok; Huh, Jung-Bo; Heo, Jae-Chan; Yun, Mi-Jung; Jeong, Chang-Mo
2014-12-01
This study evaluated the influence of abutment materials on the stability of the implant-abutment joint in internal conical connection type implant systems. Internal conical connection type implants, cement-retained abutments, and tungsten carbide-coated abutment screws were used. The abutments were fabricated with commercially pure grade 3 titanium (group T3), commercially pure grade 4 titanium (group T4), or Ti-6Al-4V (group TA) (n=5, each). In order to assess the amount of settlement after abutment fixation, a 30-Ncm tightening torque was applied, then the change in length before and after tightening the abutment screw was measured, and the preload exerted was recorded. The compressive bending strength was measured under the ISO14801 conditions. In order to determine whether there were significant changes in settlement, preload, and compressive bending strength before and after abutment fixation depending on abutment materials, one-way ANOVA and Tukey's HSD post-hoc test was performed. Group TA exhibited the smallest mean change in the combined length of the implant and abutment before and after fixation, and no difference was observed between groups T3 and T4 (P>.05). Group TA exhibited the highest preload and compressive bending strength values, followed by T4, then T3 (P<.001). The abutment material can influence the stability of the interface in internal conical connection type implant systems. The strength of the abutment material was inversely correlated with settlement, and positively correlated with compressive bending strength. Preload was inversely proportional to the frictional coefficient of the abutment material.
Dolatowski, Filip C; Adampour, Mina; Frihagen, Frede; Stavem, Knut; Erik Utvåg, Stein; Hoelsbrekken, Sigurd Erik
2016-06-01
Background and purpose - It has been suggested that preoperative posterior tilt of the femoral head may increase the risk of fixation failure in Garden-I and -II femoral neck fractures. To investigate this association, we studied a cohort of 322 such patients. Patients and methods - Patients treated with internal fixation between 2005 and 2012 were retrospectively identified using hospital records and the digital image bank. 2 raters measured the preoperative posterior tilt angle and categorized it into 3 groups: < 10°, 10-20°, and ≥ 20°. The inter-rater reliability (IRR) was determined. Patients were observed until September 2013 (with a minimum follow-up of 18 months) or until failure of fixation necessitating salvage arthroplasty. The risk of fixation failure was assessed using competing-risk regression analysis, adjusting for time to surgery. Results - Patients with a posterior tilt of ≥ 20° had a higher risk of fixation failure: 19% (8/43) as compared to 11% (14/127) in the 10-20° category and 6% (9/152) in the < 10° category (p = 0.03). Posterior tilt of ≥ 20° increased the risk of fixation failure, with an adjusted hazard ratio of 3.4 (95% CI: 1.3-8.9; p = 0.01). The interclass correlation coefficient for angular measurements of posterior tilt was 0.90 (95% CI: 0.87-0.92), and the IRR for the categorization of posterior tilt into 3 groups was 0.76 (95% CI: 0.69-0.81). Interpretation - Preoperative posterior tilt of ≥ 20° in Garden-I and -II femoral neck fractures increased the risk of fixation failure necessitating salvage arthroplasty. The reliability of the methods that we used to measure posterior tilt ranged from good to excellent.
Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.
Mohammed, R; Syed, S; Metikala, S; Ali, Sa
2011-09-01
With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.
Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury
Mohammed, R; Syed, S; Metikala, S; Ali, SA
2011-01-01
Background: With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. Materials and Methods: 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. Results: At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. Conclusion: We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures. PMID:21886929
Relevance of ammonium oxidation within biological soil crust communities
Johnson, S.L.; Budinoff, C.R.; Belnap, J.; Garcia-Pichel, F.
2005-01-01
Thin, vertically structured topsoil communities that become ecologically important in arid regions (biological soil crusts or BSCs) are responsible for much of the nitrogen inputs into pristine arid lands. We studied N2 fixation and ammonium oxidation (AO) at subcentimetre resolution within BSCs from the Colorado Plateau. Pools of dissolved porewater nitrate/ nitrite, ammonium and organic nitrogen in wetted BSCs were high in comparison with those typical of aridosoils. They remained stable during incubations, indicating that input and output processes were of similar magnitude. Areal N2 fixation rates (6.5-48 ??mol C2H2 m-2 h -1) were high, the vertical distribution of N2 fixation peaking close to the surface if populations of heterocystous cyanobacteria were present, but in the subsurface if they were absent. Areal AO rates (19-46 ??mol N m-2 h-1) were commensurate with N2 fixation inputs. When considering oxygen availability, AO activity invariably peaked 2-3 mm deep and was limited by oxygen (not ammonium) supply. Most probable number (MPN)-enumerated ammonia-oxidizing bacteria (6.7-7.9 ?? 103 cells g-1 on average) clearly peaked at 2-3 mm depth. Thus, AO (hence nitrification) is a spatially restricted but important process in the nitrogen cycling of BSC, turning much of the biologically fixed nitrogen into oxidized forms, the fate of which remains to be determined.
Blažek, Patrick; Ferri-Certić, Jerko; Vražić, Hrvoje; Lennerz, Carsten; Grebmer, Christian; Kaitani, Kazuaki; Karch, Martin; Starčević, Boris; Semmler, Verena; Kolb, Christof
2018-03-20
Fixation of the pacemaker leads during pacemaker implantation leads to an increase of cardiac Troponin T (cTnT) that can be interpreted as a sign of minimal myocardial damage. This trial evaluates whether the mechanism type of lead fixation influences the magnitude of cTnT release. Patients having a de-novo cardiac pacemaker implantation or a lead revision were centrally randomized to receive either a ventricular lead with an active (screw) or passive (tine) fixation mechanism. High-sensitive Troponin T (hsTnT) was determined on the day of the procedure beforehand and on the following day. 326 Patients (median age (IQR) 75.0 (69.0-80.0) years, 64% male) from six international centers were randomized to receive ventricular leads with an active (n = 166) or passive (n = 160) fixation mechanism. Median (IQR) hsTnT levels increased by 0.009 (0.004-0.021) ng/ml in the group receiving screw-in ventricular leads and by 0.008 (0.003-0.030) ng/ml in the group receiving tined ventricular leads (n.s.). In conclusion pacemaker implantations are followed by a release of hsTnT. The choice between active or passive fixation ventricular leads does not have a significant influence on the extent of myocardial injury and the magnitude of hsTnT release.