Hsi, Hsing-Cheng; Lee, Hsiu-Hsia; Hwang, Jyh-Feng; Chen, Wang
2010-05-01
Mercury speciation and distribution in a 660-MW tangential-fired utility boiler in Taiwan burning Australian and Chinese bituminous coal blends was investigated. Flue gases were simultaneously sampled at the selective catalytic reduction (SCR) inlet, the SCR outlet, the electrostatic precipitator (ESP) outlet, and the stack. Samplings of coal, lime, bottom ash/slag, fly ash, and gypsum slurry were also conducted. Results indicated that flue gases at the inlet to SCR contained a great potion of particle-bound mercury (Hg(p)), 59-92% of the total mercury. Removal of mercury was not observed for the SCR system. However, repartitioning of mercury species across the SCR occurred that significantly increased the portion of elemental mercury (Hg0) to up to 29% and oxidized mercury (Hg2+) to up to 33% in the SCR outlet gas. Overreporting of Hg(p) at the inlet of SCR may cause the observed repartitioning; the high ammonia/nitric oxide circumstance in the SCR unit was also speculated to cause the mercury desorption from ash particles and subsequent reentrance into the gas phase. ESP can remove up to 99% of Hg(p), and wet flue gas desulfurization (FGD) can remove up to 84% of Hg2+. Mercury mass balances were calculated to range between 81 and 127.4%, with an average of 95.7% wherein 56-82% was in ESP fly ash, 8.7-18.6% was retained in the FGD gypsum, and 6.2-26.1% was emitted from the stack. Data presented here suggest that mercury removal can be largely enhanced by increasing the conversion of Hg0 into Hg(p) and Hg2+.
Fate of Mercury in Synthetic Gypsum Used for Wallboard Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jessica Marshall Sanderson
2006-06-01
This report presents and discusses results from Task 5 of the study ''Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,'' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. The FGD process is used to control the sulfur dioxide emissions which would result in acid rain if not controlled. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasingmore » the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies developed for power plants involve the capture of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the atmosphere when the synthetic gypsum material is used as a feedstock for wallboard production. The project is being co-funded by the U.S. DOE National Energy Technology Laboratory (Cooperative Agreement DE-FC26-04NT42080), USG Corporation, and EPRI. USG Corporation is the prime contractor, and URS Group is a subcontractor. The project scope includes five discrete tasks, each conducted at various USG wallboard plants using synthetic gypsum from different FGD systems. The five tasks were to include (1) a baseline test, then variations representing differing power plant (2) emissions control configurations, (3) treatment of fine gypsum particles, (4) coal types, and (5) FGD reagent types. However, Task 5, which was to evaluate gypsum produced from an alternate FGD reagent, could not be conducted as planned. Instead, Task 5 was conducted at conditions similar to a previous task, Task 3, although with gypsum from an alternate FGD system. In this project, process stacks in the wallboard plant have been sampled using the Ontario Hydro method. The stack locations sampled for each task include a dryer for the wet gypsum as it enters the plant and a gypsum calciner. The stack of the dryer for the wet wallboard product was also tested as part of this task, and was tested as part of Tasks 1 and 4. Also at each site, in-stream process samples were collected and analyzed for mercury concentration before and after each significant step in wallboard production. The Ontario Hydro results, process sample mercury concentration data, and process data were used to construct mercury mass balances across the wallboard plants. Task 5 was conducted at a wallboard plant processing synthetic gypsum from a power plant that fires Eastern bituminous coal. The power plant is equipped with a selective catalytic reduction (SCR) system for NOX emissions control, but the SCR was bypassed during the time period the gypsum tested was produced. The power plant has a single-loop, open spray tower, limestone reagent FGD system, with forced oxidation conducted in a reaction tank integral with the FGD absorber. The FGD system has gypsum fines blow down as part of the dewatering step. Gypsum fines blow down is believed to be an important variable that impacts the amount of mercury in the gypsum byproduct and possibly its stability during the wallboard process. The results of the Task 5 stack testing, as measured by the Ontario Hydro method, detected that an average of 51% of the incoming mercury in the FGD gypsum was emitted during wallboard production. These losses were distributed as 2% or less each across the wet gypsum dryer and product wallboard dryer, and about 50% across the gypsum calciner. Emissions were similar to what Task 3 results showed, on both a percentage and a mass basis, for gypsum produced by a power plant firing bituminous coal and also having gypsum fines blow down as part of the FGD dewatering scheme. As was seen in the Task 1 through 4 results, most of the mercury detected in the stack testing on the wet gypsum dryer and kettle calciner was in the form of elemental mercury. In the wallboard dryer kiln, a more significant percentage of the mercury detected was in the oxidized form, particularly from the stack near the product discharge end of the kiln. However, this represented a very small percentage of the overall mercury loss.« less
Fate of Mercury in Synthetic Gypsum Used for Wallboard Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jessica Sanderson; Gary M. Blythe; Mandi Richardson
2006-12-01
This report presents and discusses results from Task 6 of the study 'Fate of Mercury in Synthetic Gypsum Used for Wallboard Production,' performed at a full-scale commercial wallboard plant. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies involve the capturemore » of mercury in FGD systems. The objective of this study is to determine whether any mercury is released into the atmosphere when the synthetic gypsum material is used as a feedstock for wallboard production. The project is being co-funded by the U.S. DOE National Energy Technology Laboratory (Cooperative Agreement DE-FC26-04NT42080), USG Corporation, and EPRI. USG Corporation is the prime contractor, and URS Group is a subcontractor. The project scope now includes six discrete tasks, each conducted at various USG wallboard plants using synthetic gypsum from different FGD systems. The project was originally composed of five tasks, which were to include (1) a baseline test, then variations representing differing power plant: (2) emissions control configurations, (3) treatment of fine gypsum particles, (4) coal types, and (5) FGD reagent types. However, Task 5, which was to include testing with an alternate FGD reagent, could not be conducted as planned. Instead, Task 5 was conducted at conditions similar to Task 3, although with gypsum from an alternate FGD system. Subsequent to conducting Task 5 under these revised conditions, an opportunity arose to test gypsum produced at the same FGD system, but with an additive (Degussa Corporation's TMT-15) being used in the FGD system. TMT-15 was expected to impact the stability of mercury in synthetic gypsum used to produce wallboard, so Task 6 was added to the project to test this theory. In this project, process stacks in the wallboard plant have been sampled using the Ontario Hydro method. For every task, the stack locations sampled have included a dryer for the wet gypsum as it enters the plant and a gypsum calciner. For Tasks 1, 4, 5 and 6, the stack of the dryer for the wet wallboard product was also tested. Also at each site, in-stream process samples were collected and analyzed for mercury concentration before and after each significant step in wallboard production. The Ontario Hydro results, process sample mercury concentration data, and process data were used to construct mercury mass balances across the wallboard plants. Task 6 was conducted at a wallboard plant processing synthetic gypsum from a power plant that fires Eastern bituminous coal. The power plant has a single-loop, open spray tower limestone forced oxidation FGD system, with the forced oxidation conducted in the reaction tank integral with the FGD absorber. The FGD system has gypsum fines blow down as part of the dewatering step. The power plant is equipped with a selective catalytic reduction (SCR) system for NOX emissions control, and the SCR was in service during the time period the gypsum tested was produced. Also, as mentioned above, Degussa additive TMT-15 was being added to the FGD system when this gypsum was produced. The results of the Task 6 stack testing, as measured by the Ontario Hydro method, detected that an average of 55% of the incoming mercury was emitted during wallboard production. These losses were distributed as about 4% across the dryer mill, 6% across the board dryer kiln, and 45% across the kettle calciner. Emissions were similar to what Task 5 results showed on a percentage basis, but about 30% lower on a mass basis. The same power plant FGD system produced the synthetic gypsum used in Task 5 (with no use of TMT-15) and in Task 6 (with TMT-15 added to the FGD system). The lower emissions on a mass basis appeared to be due to lower average mercury content in the gypsum being processed. It is not certain whether the lower average mercury content in the gypsum was an effect of TMT-15 addition to the FGD system. As was seen in the Task 1 through 5 results, most of the mercury detected in the Ontario Hydro method stack testing was in the form of elemental mercury.« less
Modular fuel-cell stack assembly
Patel, Pinakin
2010-07-13
A fuel cell assembly having a plurality of fuel cells arranged in a stack. An end plate assembly abuts the fuel cell at an end of said stack. The end plate assembly has an inlet area adapted to receive an exhaust gas from the stack, an outlet area and a passage connecting the inlet area and outlet area and adapted to carry the exhaust gas received at the inlet area from the inlet area to the outlet area. A further end plate assembly abuts the fuel cell at a further opposing end of the stack. The further end plate assembly has a further inlet area adapted to receive a further exhaust gas from the stack, a further outlet area and a further passage connecting the further inlet area and further outlet area and adapted to carry the further exhaust gas received at the further inlet area from the further inlet area to the further outlet area.
Method of making a small inlet optical panel
Veligdan, James T.; Slobodin, David E.
2004-02-03
An optical panel having a small inlet, and a method of making a small inlet optical panel, are disclosed, which optical panel includes a individually coating, stacking, and cutting a first plurality of stacked optical waveguides to form an outlet face body with an outlet face, individually coating, stacking, and cutting a second plurality of stacked optical waveguides to form an inlet face body with an inlet face, and connecting an optical coupling element to the first plurality and second plurality of stacked optical waveguides, wherein the optical coupling element redirects light along a parallel axis of the inlet face to a parallel axis of the outlet face. In the preferred embodiment of the present invention, the inlet face is disposed obliquely with and askew from the outlet face.
Monopolar fuel cell stack coupled together without use of top or bottom cover plates or tie rods
NASA Technical Reports Server (NTRS)
Narayanan, Sekharipuram R. (Inventor); Valdez, Thomas I. (Inventor)
2009-01-01
A monopolar fuel cell stack comprises a plurality of sealed unit cells coupled together. Each unit cell comprises two outer cathodes adjacent to corresponding membrane electrode assemblies and a center anode plate. An inlet and outlet manifold are coupled to the anode plate and communicate with a channel therein. Fuel flows from the inlet manifold through the channel in contact with the anode plate and flows out through the outlet manifold. The inlet and outlet manifolds are arranged to couple to the inlet and outlet manifolds respectively of an adjacent one of the plurality of unit cells to permit fuel flow in common into all of the inlet manifolds of the plurality of the unit cells when coupled together in a stack and out of all of the outlet manifolds of the plurality of unit cells when coupled together in a stack.
Small inlet optical panel and a method of making a small inlet optical panel
Veligdan, James T.; Slobodin, David
2001-01-01
An optical panel having a small inlet, and a method of making a small inlet optical panel, are disclosed, which optical panel includes a individually coating, stacking, and cutting a first plurality of stacked optical waveguides to form an outlet face body with an outlet face, individually coating, stacking, and cutting a second plurality of stacked optical waveguides to form an inlet face body with an inlet face, and connecting an optical coupling element to the first plurality and to the second plurality, wherein the optical coupling element redirects light along a parallel axis of the inlet face to a parallel axis of the outlet face. In the preferred embodiment of the present invention, the inlet face is disposed obliquely with and askew from the outlet face.
Light Redirective Display Panel And A Method Of Making A Light Redirective Display Panel
Veligdan, James T.
2005-07-26
An optical display panel which provides improved light intensity at a viewing angle by redirecting light emitting from the viewing screen, and a method of making a light redirective display panel, are disclosed. The panel includes an inlet face at one end for receiving light, and an outlet screen at an opposite end for displaying the light. The inlet face is defined at one end of a transparent body, which body may be formed by a plurality of waveguides, and the outlet screen is defined at an opposite end of the body. The screen includes light redirective elements at the outlet screen for re-directing light emitting from the outlet screen. The method includes stacking a plurality of glass sheets, with a layer of adhesive or epoxy between each sheet, curing the adhesive to form a stack, placing the stack against a saw and cutting the stack at two opposite ends to form a wedge-shaped panel having an inlet face and an outlet face, and forming at the outlet face a plurality of light redirective elements which direct light incident on the outlet face into a controlled light cone.
Light redirective display panel and a method of making a light redirective display panel
Veligdan, James T.
2002-01-01
An optical display panel which provides improved light intensity at a viewing angle by redirecting light emitting from the viewing screen, and a method of making a light redirective display panel, are disclosed. The panel includes an inlet face at one end for receiving light, and an outlet screen at an opposite end for displaying the light. The inlet face is defined at one end of a transparent body, which body may be formed by a plurality of waveguides, and the outlet screen is defined at an opposite end of the body. The screen includes light redirective elements at the outlet screen for re-directing light emitting from the outlet screen. The method includes stacking a plurality of glass sheets, with a layer of adhesive or epoxy between each sheet, curing the adhesive to form a stack, placing the stack against a saw and cutting the stack at two opposite ends to form a wedge-shaped panel having an inlet face and an outlet face, and forming at the outlet face a plurality of light redirective elements which direct light incident on the outlet face into a controlled light cone.
Summary of Part 75 Administrative Processes: Table 6
Learn how to submit information for a new unit, new stack or new FGD; unit shutdown and restart, long term cold storage (LTCS), expected restart date, postponement of Appendix E testing, backup fuel used, and notice of combustion of emergency fuel.
Selenium Partitioning and Removal Across a Wet FGD Scrubber at a Coal-Fired Power Plant.
Senior, Constance L; Tyree, Corey A; Meeks, Noah D; Acharya, Chethan; McCain, Joseph D; Cushing, Kenneth M
2015-12-15
Selenium has unique fate and transport through a coal-fired power plant because of high vapor pressures of oxide (SeO2) in flue gas. This study was done at full-scale on a 900 MW coal-fired power plant with electrostatic precipitator (ESP) and wet flue gas desulfurization (FGD) scrubber. The first objective was to quantify the partitioning of selenium between gas and condensed phases at the scrubber inlet and outlet. The second objective was to determine the effect of scrubber operation conditions (pH, mass transfer, SO2 removal) on Se removal in both particulate and vapor phases. During part of the testing, hydrated lime (calcium hydroxide) was injected upstream of the scrubber. Gas-phase selenium and particulate-bound selenium were measured as a function of particle size at the inlet and outlet of the scrubber. The total (both phases) removal of Se across the scrubber averaged 61%, and was enhanced when hydrated lime sorbent was injected. There was evidence of gas-to-particle conversion of selenium across the scrubber, based on the dependence of selenium concentration on particle diameter downstream of the scrubber and on thermodynamic calculations.
Biomass bale stack and field outlet locations assessment for efficient infield logistics
USDA-ARS?s Scientific Manuscript database
Harvested hay or biomass are traditionally baled for better handling and they are transported to the outlet for final utilization. For better management of bale logistics, producers often aggregate bales into stacks so that bale-hauling equipment can haul multiple bales for improved efficiency. Obje...
Fate of Mercury in Synthetic Gypsum Used for Wallboard Production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jessica Sanderson
2007-12-31
This report presents and discusses results from the project 'Fate of Mercury in Synthetic Gypsum Used for Wallboard Production', performed at five different full-scale commercial wallboard plants. Synthetic gypsum produced by wet flue gas desulfurization (FGD) systems on coal-fired power plants is commonly used in the manufacture of wallboard. This practice has long benefited the environment by recycling the FGD gypsum byproduct, which is becoming available in increasing quantities, decreasing the need to landfill this material, and increasing the sustainable design of the wallboard product. However, new concerns have arisen as recent mercury control strategies involve the capture of mercurymore » in FGD systems. The objective of this study has been to determine whether any mercury is released into the atmosphere at wallboard manufacturing plants when the synthetic gypsum material is used as a feedstock for wallboard production. The project has been co-funded by the U.S. DOE National Energy Technology Laboratory (Cooperative Agreement DE-FC26-04NT42080), USG Corporation, and EPRI. USG Corporation is the prime contractor, and URS Group is a subcontractor. The project scope included seven discrete tasks, each including a test conducted at various USG wallboard plants using synthetic gypsum from different wet FGD systems. The project was originally composed of five tasks, which were to include (1) a base-case test, then variations representing differing power plant: (2) emissions control configurations, (3) treatment of fine gypsum particles, (4) coal types, and (5) FGD reagent types. However, Task 5,could not be conducted as planned and instead was conducted at conditions similar to Task 3. Subsequently an opportunity arose to test gypsum produced from the Task 5 FGD system, but with an additive expected to impact the stability of mercury, so Task 6 was added to the project. Finally, Task 7 was added to evaluate synthetic gypsum produced at a power plant from an additional coal type. In the project, process stacks in the wallboard plant were sampled using the Ontario Hydro method. In every task, the stack locations sampled included a gypsum dryer and a gypsum calciner. In Tasks 1 and 4 through 7, the stack of the dryer for the wet wallboard product was also tested. Also at each site, in-stream process samples were collected and analyzed for mercury concentration before and after each significant step in wallboard production. These results and process data were used to construct mercury mass balances across the wallboard plants. The results from the project showed a wide range of percentage mercury losses from the synthetic gypsum feedstocks as measured by the Ontario Hydro method at the process stacks, ranging from 2% to 55% of the mercury in the gypsum feedstock. For the tasks exceeding 10% mercury loss across the wallboard plant, most of the loss occurred across the gypsum calciner. When total wallboard emissions remained below 10%, the primary emission location varied with a much less pronounced difference in emission between the gypsum dryer, calciner and board dryer. For all seven tasks, the majority of the mercury emissions were measured to be in the elemental form (Hg{sup 0}). Overall, the measured mercury loss mass rates ranged from 0.01 to 0.17 grams of mercury per dry ton of synthetic gypsum processed, or 0.01 to 0.4 pounds of mercury released per million square feet of wallboard produced from synthetic gypsum. The Coal Combustion Product Production and Use Survey from the American Coal Ash Association (ACAA) indicate that 7,579,187 short tons of synthetic gypsum were used for wallboard production in 2006. Extrapolating the results of this study to the ACAA industry usage rate, we estimate that mercury releases from wallboard production plants in 2006 ranged between 150 to 3000 pounds for the entire U.S. wallboard industry. With only seven sets of wallboard plant measurements, it is difficult to draw firm conclusions about what variables impact the mercury loss percentages across the wallboard plants. One significant observation from this study was that higher purge rates of chlorides and fine solid particles from the wet FGD systems appear to produce gypsum with lower mercury concentrations. Any chemical interaction between mercury and chlorides is not well understood; however, based on the information available the lower mercury content in the gypsum product is likely due to the blow down of fine, mercury-rich particles as opposed to a decreased chloride concentration. One possible explanation is that a decrease of fine particles in the FGD slurry allows for less adsorption of mercury onto those particles, thus the mercury remains with the FGD liquor rather than the gypsum product. A more detailed discussion on synthetic gypsum sources and FGD chemistry data can be found in the Experimental section of this report and Table 4.« less
Ultrathin Optical Panel And A Method Of Making An Ultrathin Optical Panel.
Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Veligdan, James T.
2005-02-15
An ultrathin optical panel, and a method of producing an ultrathin optical panel, are disclosed, including stacking a plurality of glass sheets, which sheets may be coated with a transparent cladding substance or may be uncoated, fastening together the plurality of stacked coated glass sheets using an epoxy or ultraviolet adhesive, applying uniform pressure to the stack, curing the stack, sawing the stack to form an inlet face on a side of the stack and an outlet face on an opposed side of the stack, bonding a coupler to the inlet face of the stack, and fastening the stack, having the coupler bonded thereto, within a rectangular housing having an open front which is aligned with the outlet face, the rectangular housing having therein a light generator which is optically aligned with the coupler. The light generator is preferably placed parallel to and proximate with the inlet face, thereby allowing for a reduction in the depth of the housing.
Ultrathin Optical Panel And A Method Of Making An Ultrathin Optical Panel.
Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Veligdan, James T.
2005-05-17
An ultrathin optical panel, and a method of producing an ultrathin optical panel, are disclosed, including stacking a plurality of glass sheets, which sheets may be coated with a transparent cladding substance or may be uncoated, fastening together the plurality of stacked coated glass sheets using an epoxy or ultraviolet adhesive, applying uniform pressure to the stack, curing the stack, sawing the stack to form an inlet face on a side of the stack and an outlet face on an opposed side of the stack, bonding a coupler to the inlet face of the stack, and fastening the stack, having the coupler bonded thereto, within a rectangular housing having an open front which is aligned with the outlet face, the rectangular housing having therein a light generator which is optically aligned with the coupler. The light generator is preferably placed parallel to and proximate with the inlet face, thereby allowing for a reduction in the depth of the housing.
Ultrathin optical panel and a method of making an ultrathin optical panel
Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Veligdan, James T.
2003-02-11
An ultrathin optical panel, and a method of producing an ultrathin optical panel, are disclosed, including stacking a plurality of glass sheets, which sheets may be coated with a transparent cladding substance or may be uncoated, fastening together the plurality of stacked coated glass sheets using an epoxy or ultraviolet adhesive, applying uniform pressure to the stack, curing the stack, sawing the stack to form an inlet face on a side of the stack and an outlet face on an opposed side of the stack, bonding a coupler to the inlet face of the stack, and fastening the stack, having the coupler bonded thereto, within a rectangular housing having an open front which is aligned with the outlet face, the rectangular housing having therein a light generator which is optically aligned with the coupler. The light generator is preferably placed parallel to and proximate with the inlet face, thereby allowing for a reduction in the depth of the housing.
Ultrathin optical panel and a method of making an ultrathin optical panel
Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Veligdan, James T.
2001-10-09
An ultrathin optical panel, and a method of producing an ultrathin optical panel, are disclosed, including stacking a plurality of glass sheets, which sheets may be coated with a transparent cladding substance or may be uncoated, fastening together the plurality of stacked coated glass sheets using an epoxy or ultraviolet adhesive, applying uniform pressure to the stack, curing the stack, sawing the stack to form an inlet face on a side of the stack and an outlet face on an opposed side of the stack, bonding a coupler to the inlet face of the stack, and fastening the stack, having the coupler bonded thereto, within a rectangular housing having an open front which is aligned with the outlet face, the rectangular housing having therein a light generator which is optically aligned with the coupler. The light generator is preferably placed parallel to and proximate with the inlet face, thereby allowing for a reduction in the depth of the housing.
Ultrathin optical panel and a method of making an ultrathin optical panel
Biscardi, Cyrus; Brewster, Calvin; DeSanto, Leonard; Veligdan, James T.
2002-01-01
An ultrathin optical panel, and a method of producing an ultrathin optical panel, are disclosed, including stacking a plurality of glass sheets, which sheets may be coated With a transparent cladding substance or may be uncoated, fastening together the plurality of stacked coated glass sheets using an epoxy or ultraviolet adhesive, applying uniform pressure to the stack, curing the stack, sawing the stack to form an inlet face on a side of the stack and an outlet face on an opposed side of the stack, bonding a coupler to the inlet face of the stack, and fastening the stack, having the coupler bonded thereto, within a rectangular housing having an open front which is aligned with the outlet face, the rectangular housing having therein a light generator which is optically aligned with the coupler. The light generator is preferably placed parallel to and proximate with the inlet face, thereby allowing for a reduction in the depth of the housing.
New design of a PEFC cathode separator of for water management
NASA Astrophysics Data System (ADS)
Sugiura, K.; Takahashi, N.; Kamimura, T.
2017-11-01
Generally, polymer electrolyte fuel cells (PEFCs) need humidifiers to prevent the drying of the membrane, but this use of humidifiers creates water management issues, such as the flooding/plugging phenomena and decreased system efficiency because of an increase in the electric energy needed for auxiliary equipment. Although most researchers have developed high-temperature membranes that do not need humidifiers, a lot of time is necessary for the development of these membranes, and these membranes drive up costs. Therefore, we propose a new cathode separator design that can recycle water generated by power generation in the same cell and a stack structure that can redistribute water collected in the cathode outlet manifold to drying cells. Because the new cathode separator has a bypass channel from the gas outlet to the gas inlet to transport excess water, a dry part in the gas inlet is supplied with excess water in the gas outlet through the bypass channel even if the PEFC is operated under dry conditions. Excess water in the PEFC stack can be transported from the cell with excess water to the drying cell through the cathode outlet manifold with a porous wall. Therefore, we confirm the influence of the plugging phenomenon in the cathode gas outlet manifold on the cell performance of each cell in the stack. As a result, the cell performance of the new cathode separator design is better than that of the standard separator under the low humidity conditions. We confirm that the plugging phenomenon in the cathode outlet manifold affects the cell performance of each cell in the stack.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Under contract with the US Department of Energy (DE-AC22-92PCO0367), Pittsburgh Energy Technology Center, Radian Corporation has conducted a test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPS). Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical charactization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on themore » relative toxicological effects of exposure to particulate emissions.« less
Wu, Chengli; Cao, Yan; Dong, Zhongbing; Cheng, Chinmin; Li, Hanxu; Pan, Weiping
2010-01-01
Air pollution control devices (APCDs) are installed at coal-fired power plants for air pollutant regulation. Selective catalytic reduction (SCR) and wet flue gas desulfurization (FGD) systems have the co-benefits of air pollutant and mercury removal. Configuration and operational conditions of APCDs and mercury speciation affect mercury removal efficiently at coal-fired utilities. The Ontario Hydro Method (OHM) recommended by the U.S. Environmental Protection Agency (EPA) was used to determine mercury speciation simultaneously at five sampling locations through SCR-ESP-FGD at a 190 MW unit. Chlorine in coal had been suggested as a factor affecting the mercury speciation in flue gas; and low-chlorine coal was purported to produce less oxidized mercury (Hg2+) and more elemental mercury (Hg0) at the SCR inlet compared to higher chlorine coal. SCR could oxidize elemental mercury into oxidized mercury when SCR was in service, and oxidation efficiency reached 71.0%. Therefore, oxidized mercury removal efficiency was enhanced through a wet FGD system. In the non-ozone season, about 89.5%-96.8% of oxidized mercury was controlled, but only 54.9%-68.8% of the total mercury was captured through wet FGD. Oxidized mercury removal efficiency was 95.9%-98.0%, and there was a big difference in the total mercury removal efficiencies from 78.0% to 90.2% in the ozone season. Mercury mass balance was evaluated to validate reliability of OHM testing data, and the ratio of mercury input in the coal to mercury output at the stack was from 0.84 to 1.08.
High specific power, direct methanol fuel cell stack
Ramsey, John C [Los Alamos, NM; Wilson, Mahlon S [Los Alamos, NM
2007-05-08
The present invention is a fuel cell stack including at least one direct methanol fuel cell. A cathode manifold is used to convey ambient air to each fuel cell, and an anode manifold is used to convey liquid methanol fuel to each fuel cell. Tie-bolt penetrations and tie-bolts are spaced evenly around the perimeter to hold the fuel cell stack together. Each fuel cell uses two graphite-based plates. One plate includes a cathode active area that is defined by serpentine channels connecting the inlet manifold with an integral flow restrictor to the outlet manifold. The other plate includes an anode active area defined by serpentine channels connecting the inlet and outlet of the anode manifold. Located between the two plates is the fuel cell active region.
Improved Direct Methanol Fuel Cell Stack
Wilson, Mahlon S.; Ramsey, John C.
2005-03-08
A stack of direct methanol fuel cells exhibiting a circular footprint. A cathode and anode manifold, tie-bolt penetrations and tie-bolts are located within the circular footprint. Each fuel cell uses two graphite-based plates. One plate includes a cathode active area that is defined by serpentine channels connecting the inlet and outlet cathode manifold. The other plate includes an anode active area defined by serpentine channels connecting the inlet and outlet of the anode manifold, where the serpentine channels of the anode are orthogonal to the serpentine channels of the cathode. Located between the two plates is the fuel cell active region.
Active microchannel fluid processing unit and method of making
Bennett, Wendy D [Kennewick, WA; Martin, Peter M [Kennewick, WA; Matson, Dean W [Kennewick, WA; Roberts, Gary L [West Richland, WA; Stewart, Donald C [Richland, WA; Tonkovich, Annalee Y [Pasco, WA; Zilka, Jennifer L [Pasco, WA; Schmitt, Stephen C [Dublin, OH; Werner, Timothy M [Columbus, OH
2001-01-01
The present invention is an active microchannel fluid processing unit and method of making, both relying on having (a) at least one inner thin sheet; (b) at least one outer thin sheet; (c) defining at least one first sub-assembly for performing at least one first unit operation by stacking a first of the at least one inner thin sheet in alternating contact with a first of the at least one outer thin sheet into a first stack and placing an end block on the at least one inner thin sheet, the at least one first sub-assembly having at least a first inlet and a first outlet; and (d) defining at least one second sub-assembly for performing at least one second unit operation either as a second flow path within the first stack or by stacking a second of the at least one inner thin sheet in alternating contact with second of the at least one outer thin sheet as a second stack, the at least one second sub-assembly having at least a second inlet and a second outlet.
Active microchannel fluid processing unit and method of making
Bennett, Wendy D [Kennewick, WA; Martin, Peter M [Kennewick, WA; Matson, Dean W [Kennewick, WA; Roberts, Gary L [West Richland, WA; Stewart, Donald C [Richland, WA; Tonkovich, Annalee Y [Pasco, WA; Zilka, Jennifer L [Pasco, WA; Schmitt, Stephen C [Dublin, OH; Werner, Timothy M [Columbus, OH
2002-12-10
The present invention is an active microchannel fluid processing unit and method of making, both relying on having (a) at least one inner thin sheet; (b) at least one outer thin sheet; (c) defining at least one first sub-assembly for performing at least one first unit operation by stacking a first of the at least one inner thin sheet in alternating contact with a first of the at least one outer thin sheet into a first stack and placing an end block on the at least one inner thin sheet, the at least one first sub-assembly having at least a first inlet and a first outlet; and (d) defining at least one second sub-assembly for performing at least one second unit operation either as a second flow path within the first stack or by stacking a second of the at least one inner thin sheet in alternating contact with second of the at least one outer thin sheet as a second stack, the at least one second sub-assembly having at least a second inlet and a second outlet.
Mercury emission and speciation of coal-fired power plants in China
NASA Astrophysics Data System (ADS)
Wang, S. X.; Zhang, L.; Li, G. H.; Wu, Y.; Hao, J. M.; Pirrone, N.; Sprovieri, F.; Ancora, M. P.
2010-02-01
Comprehensive field measurements are needed to understand the mercury emissions from Chinese power plants and to improve the accuracy of emission inventories. Characterization of mercury emissions and their behavior were measured in six typical coal-fired power plants in China. During the tests, the flue gas was sampled simultaneously at inlet and outlet of Selective Catalytic Reduction (SCR), electrostatic precipitators (ESP), and flue gas desulfurization (FGD) using the Ontario Hydro Method (OHM). The pulverized coal, bottom ash, fly ash and gypsum were also sampled in the field. Mercury concentrations in coal burned in the measured power plants ranged from 17 to 385 μg/kg. The mercury mass balances for the six power plants varied from 87 to 116% of the input coal mercury for the whole system. The total mercury concentrations in the flue gas from boilers were at the range of 1.92-27.15 μg/m3, which were significantly related to the mercury contents in burned coal. The mercury speciation in flue gas right after the boiler is influenced by the contents of halogen, mercury, and ash in the burned coal. The average mercury removal efficiencies of ESP, ESP plus wet FGD, and ESP plus dry FGD-FF systems were 24%, 73% and 66%, respectively, which were similar to the average removal efficiencies of pollution control device systems in other countries such as US, Japan and South Korea. The SCR system oxidized 16% elemental mercury and reduced about 32% of total mercury. Elemental mercury, accounting for 66-94% of total mercury, was the dominant species emitted to the atmosphere. The mercury emission factor was also calculated for each power plant.
Mercury emission and speciation of coal-fired power plants in China
NASA Astrophysics Data System (ADS)
Wang, S.; Zhang, L.; Li, G.; Wu, Y.; Hao, J.; Pirrone, N.; Sprovieri, F.; Ancora, M. P.
2009-11-01
Comprehensive field measurements are needed to understand the mercury emissions from Chinese power plants and to improve the accuracy of emission inventories. Characterization of mercury emissions and their behavior were measured in six typical coal-fired power plants in China. During the tests, the flue gas was sampled simultaneously at inlet and outlet of selective catalyst reduction (SCR), electrostatic precipitators (ESP), and flue gas desulfurization (FGD) using the Ontario Hydro Method (OHM). The pulverized coal, bottom ash, fly ash and gypsum were also sampled in the field. Mercury concentrations in coal burned in the measured power plants ranged from 17 to 385 μg/kg. The mercury mass balances for the six power plants varied from 87 to 116% of the input coal mercury for the whole system. The total mercury concentrations in the flue gas from boilers were at the range of 1.92-27.15 μg/m3, which were significantly related to the mercury contents in burned coal. The mercury speciation in flue gas right after the boiler is influenced by the contents of halogen, mercury, and ash in the burned coal. The average mercury removal efficiencies of ESP, ESP plus wet FGD, and ESP plus dry FGD-FF systems were 24%, 73% and 66%, respectively, which were similar to the average removal efficiencies of pollution control device systems in other countries such as US, Japan and South Korea. The SCR system oxidized 16% elemental mercury and reduced about 32% of total mercury. Elemental mercury, accounting for 66-94% of total mercury, was the dominant species emitted to the atmosphere. The mercury emission factor was also calculated for each power plant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ettore Guerriero; Antonina Lutri; Rosanna Mabilia
2008-11-15
A monitoring campaign of polychlorinated dibenzo-p-dioxins and dibenzofurans, polyaromatic hydrocarbons (PAHs), and polychlorinated biphenyl was carried out in an Italian iron ore sintering plant by sampling the combustion gases at the electrostatic precipitator (ESP) outlet, at the Wetfine scrubber (WS) outlet, and by collecting the ESP dust. Few data are available on these micropollutants produced in iron ore sintering plants, particularly from Italian plants. This study investigates the PAH emission profiles and the removal efficiency of ESPs and WS. PAHs were determined at the stack, ESP outlet flue gases, and in ESP dust to characterize the emission profiles and themore » performance of the ESP and the WS for reducing PAH emission. The 11 PAHs monitored are listed in the Italian legislative decree 152/2006. The mean total PAH sum concentration in the stack flue gases is 3.96 {mu}g/N m{sup 3}, in ESP outlet flue gases is 9.73 {mu}g/N m{sup 3}, and in ESP dust is 0.53 {mu}g/g. Regarding the emission profiles, the most abundant compound is benzo(b)fluoranthene, which has a relative low BaP toxic equivalency factors (TEF) value, followed by dibenzo(a,l)pyrene, which has a very high BaP(TEF) value. The emission profiles in ESP dust and in the flue gases after the ESP show some changes, whereas the fingerprint in ESP and stack flue gases is very similar. The removal efficiency of the ESP and of WS on the total PAH concentration is 5.2 and 59.5%, respectively. 2 figs., 5 tabs.« less
Internal reforming fuel cell assembly with simplified fuel feed
Farooque, Mohammad; Novacco, Lawrence J.; Allen, Jeffrey P.
2001-01-01
A fuel cell assembly in which fuel cells adapted to internally reform fuel and fuel reformers for reforming fuel are arranged in a fuel cell stack. The fuel inlet ports of the fuel cells and the fuel inlet ports and reformed fuel outlet ports of the fuel reformers are arranged on one face of the fuel cell stack. A manifold sealing encloses this face of the stack and a reformer fuel delivery system is arranged entirely within the region between the manifold and the one face of the stack. The fuel reformer has a foil wrapping and a cover member forming with the foil wrapping an enclosed structure.
Fuel cell system blower configuration
Patel, Kirtikumar H.; Saito, Kazuo
2017-11-28
An exemplary fuel cell system includes a cell stack assembly having a plurality of cathode components and a plurality of anode components. A first reactant blower has an outlet situated to provide a first reactant to the cathode components. A second reactant blower has an outlet situated to provide a second reactant to the anode components. The second reactant blower includes a fan portion that moves the second reactant through the outlet. The second reactant blower also includes a motor portion that drives the fan portion and a bearing portion associated with the fan portion and the motor portion. The motor portion has a motor coolant inlet coupled with the outlet of the first reactant blower to receive some of the first reactant for cooling the motor portion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong Shiyun, E-mail: tjzhongshiyun@163.com; Ni Kun; Li Jinmei
2012-07-15
Highlights: Black-Right-Pointing-Pointer The mortar with uncalcined FGD gypsum has suitable workability. Black-Right-Pointing-Pointer The strength of mortar with uncalcined FGD gypsum is higher than that of mortar without uncalcined FGD gypsum. Black-Right-Pointing-Pointer The dry shrinkage of mortar with uncalcined FGD gypsum is lower than that of mortar without uncalcined FGD gypsum. Black-Right-Pointing-Pointer The leaching of sulfate ion of mortar is studied. - Abstract: A series of novel mortars were developed from composite binder of uncalcined FGD gypsum, fly ash (FA) and ground granulated blast furnace slag (GGBFS) for the good utilization of flue gas desulphurization (FGD) gypsum. At a fixed ratiomore » (20%) of GGBFS to the composite binder, keeping consistency of the mortar between 9.5 and 10.0 cm, the properties of the composite mortar were studied. The results show that higher water/binder (W/B) is required to keep the consistency when increasing the percentage of FGD gypsum. No obvious influences of the W/B and content of FGD gypsum on the bleeding of paste were observed which keeps lower than 2% under all experimental conditions tried. The highest compressive and flexural strengths (ratio is 20% FGD gypsum, 20% GGBFS and 60% FA) are 22.6 and 4.3 MPa at 28 days, respectively. Scanning electron microscopy (SEM) and X-ray diffraction (XRD) results indicate that massive ettringite crystals and C-S-H gels exist in the hydration products. At 90 days the mortars with FGD gypsum is dramatically smaller drying shrinkage (563-938 micro strain) than that without FGD gypsum (about 2250 micro strain). The release of the SO{sub 4}{sup 2-} from the mortar was analyzed, indicating that the dissolution of sulfate increases with FGD gypsum. The concentration of SO{sub 4}{sup 2-} releasing from the mortar with 10% FGD gypsum is almost equal to that obtained from the mortar without FGD gypsum. The release of SO{sub 4}{sup 2-} from the mortar with 20% FGD gypsum is 9200 mg{center_dot}m{sup -2}, which is lower than that from the mortar with 95% cement clinker and 5% FGD gypsum.« less
Kippenhan, D.O.
1962-09-25
An accurately controlled, pulse gas valve is designed capable of delivering output pulses which vary in length from one-tenth millisecond to one second or more, repeated at intervals of a few milliseconds or- more. The pulsed gas valve comprises a column formed of barium titanate discs mounted in stacked relation and electrically connected in parallel, with means for applying voltage across the discs to cause them to expand and effect a mechanical elongation axially of the column. The column is mounted within an enclosure having an inlet port and an outlet port with an internal seat in communication with the outlet port, such that a plug secured to the end of the column will engage the seat of the outlet port to close the outlet port in response to the application of voltage is regulated by a conventional electronic timing circuit connected to the column. (AEC)
NASA Astrophysics Data System (ADS)
Suter, C.; Jovanovic, Z.; Steinfeld, A.
2012-06-01
A thermoelectric stack composed of arrays of Bi-Te alloy thermoelectric converter (TEC) modules is considered for geothermal heat conversion. The TEC modules consist of Al2O3 plates with surface 30×30 mm2 and 127 p-type (Bi0.2Sb0.8)2Te3 and n-type Bi2(Te0.96Se0.04)3 thermoelement pairs, each having a cross-section of 1.05×1.05 mm2, and with a figure-of-merit of 1 and a heat-to-electricity conversion efficiency of ˜5%. A heat transfer model is formulated to couple conduction in the thermoelements with convection between the Al2O3 plates and the water flow in counter-flow channel configuration. The calculated open-circuit voltages are compared to those resulting from the mean temperature differences across the TEC modules computed by CFD. The investigated parameters are: hot water inlet and outlet temperatures (373 - 413 K and 323 - 363 K, respectively), stack length (300 - 1500 mm), thermoelement length (1 - 4 mm) and hot channel heights (0.2 - 2 mm). The heat transfer model is then applied to optimize a 1 kWel stack with hot water inlet at 393 K and outlet at 353 K for either maximum heat-to-electricity conversion efficiency of 2.9% or minimum size of 0.0044 m3.
Veligdan, James T.
2001-01-01
An optical panel includes stacked optical waveguides having stepped inlet facets collectively defining an inlet face for receiving image light, and having beveled outlet faces collectively defining a display screen for displaying the image light channeled through the waveguides by internal reflection.
Flue gas desulfurization method and apparatus
Madden, Deborah A.; Farthing, George A.
1998-08-18
A combined furnace limestone injection and dry scrubber flue gas desulfurization (FGD) system collects solids from the flue gas stream in first particulate collection device located downstream of an outlet of a convection pass of the furnace and upstream of the dry scrubber. The collected solids are diverted to the dry scrubber feed slurry preparation system to increase sulfur oxide species removal efficiency and sorbent utilization. The level of lime in the feed slurry provided to the dry scrubber is thus increased, which enhances removal of sulfur oxide species in the dry scrubber. The decreased particulate loading to the dry scrubber helps maintain a desired degree of free moisture in the flue gas stream entering the dry scrubber, which enhances sulfur oxide species removal both in the dry scrubber and downstream particulate collector, normally a baghouse.
Flue gas desulfurization method and apparatus
Madden, Deborah A.; Farthing, George A.
1998-09-29
A combined furnace limestone injection and dry scrubber flue gas desulfurization (FGD) system collects solids from the flue gas stream in first particulate collection device located downstream of an outlet of a convection pass of the furnace and upstream of the dry scrubber. The collected solids are diverted to the dry scrubber feed slurry preparation system to increase sulfur oxide species removal efficiency and sorbent utilization. The level of lime in the feed slurry provided to the dry scrubber is thus increased, which enhances removal of sulfur oxide species in the dry scrubber. The decreased particulate loading to the dry scrubber helps maintain a desired degree of free moisture in the flue gas stream entering the dry scrubber, which enhances sulfur oxide species removal both in the dry scrubber and downstream particulate collector, normally a baghouse.
Effects of FGD-gypsum, used-wallboard and calcium sulfate on corn and soybean root growth
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization (FGD)-gypsum production has increased 44 percent from 2007 to 2008. The major use of FGD-gypsum today is in the wallboard industry. Reduction in the construction, however, reduces the demand for wallboard. Agriculture could become the second largest user of FGD-gypsum. F...
Disturbances of automatic gait control mechanisms in higher level gait disorder.
Danoudis, Mary; Ganesvaran, Ganga; Iansek, Robert
2016-07-01
The underlying mechanisms responsible for the gait changes in frontal gait disorder (FGD), a form of higher level gait disorders, are poorly understood. We investigated the relationship between stride length and cadence (SLCrel) in people with FGD (n=15) in comparison to healthy older adults (n=21) to improve our understanding of the changes to gait in FGD. Gait data was captured using an electronic walkway system as participants walked at five self-selected speed conditions: preferred, very slow, slow, fast and very fast. Linear regression was used to determine the strength of the relationship (R(2)), slope and intercept. In the FGD group 9 participants had a strong SLCrel (linear group) (R(2)>0.8) and 6 a weak relationship (R(2)<0.8) (nonlinear group). The linear FGD group did not differ to healthy control for slope (p>0.05) but did have a lower intercept (p<0.001). The linear FGD group modulated gait speed by adjusting stride length and cadence similar to controls whereas the nonlinear FGD participants adjusted stride length but not cadence similar to controls. The non-linear FGD group had greater disturbance to their gait, poorer postural control and greater fear of falling compared to the linear FGD group. Investigation of the SLCrel resulted in new insights into the underlying mechanisms responsible for the gait changes found in FGD. The findings suggest stride length regulation was disrupted in milder FGD but as the disorder worsened, cadence control also became disordered resulting in a break down in the relationship between stride length and cadence. Copyright © 2016 Elsevier B.V. All rights reserved.
40 CFR 60.747 - Reporting and recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...
40 CFR 60.747 - Reporting and recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...
40 CFR 60.747 - Reporting and recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...
40 CFR 60.747 - Reporting and recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels... recent performance test that demonstrated compliance. (ii) For carbon adsorption systems with individual...
THE EFFECT OF MERCURY CONTROLS ON WALLBOARD MANUFACTURE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandra Meischen
2004-07-01
Pending EPA regulations may mandate 70 to 90% mercury removal efficiency from utility flue gas. A mercury control option is the trapping of oxidized mercury in wet flue gas desulfurization systems (FGD). The potential doubling of mercury in the FGD material and its effect on mercury volatility at temperatures common to wallboard manufacture is a concern that could limit the growing byproduct use of FGD material. Prediction of mercury fate is limited by lack of information on the mercury form in the FGD material. The parts per billion mercury concentrations prevent the identification of mercury compounds by common analytical methods.more » A sensitive analytical method, cold vapor atomic fluorescence, coupled with leaching and thermodecomposition methods were evaluated for their potential to identify mercury compounds in FGD material. The results of the study suggest that the mercury form is dominated by the calcium sulfate matrix and is probably associated with the sulfate form in the FGD material. Additionally, to determine the effect of high mercury concentration FGD material on wallboard manufacture, a laboratory FGD unit was built to trap the oxidized mercury generated in a simulated flue gas. Although the laboratory prepared FGD material did not contain the mercury concentrations anticipated, further thermal tests determined that mercury begins to evolve from FGD material at 380 to 390 F, consequently dropping the drying temperature should mitigate mercury evolution if necessary. Mercury evolution is also diminished as the weight of the wallboard sample increased. Consequently, mercury evolution may not be a significant problem in wallboard manufacture.« less
Hoffman, Melvin G.; Janneck, Frank W.
1982-01-01
A combustor for a gas turbine engine includes a metal engine block including a wall portion defining a housing for a combustor having ceramic liner components. A ceramic outlet duct is supported by a compliant seal on the metal block and a reaction chamber liner is stacked thereon and partly closed at one end by a ceramic bypass swirl plate which is spring loaded by a plurality of circumferentially spaced, spring loaded guide rods and wherein each of the guide rods has one end thereof directed exteriorly of a metal cover plate on the engine block to react against externally located biasing springs cooled by ambient air and wherein the rod spring support arrangement maintains the stacked ceramic components together so that a normal force is maintained on the seal between the outlet duct and the engine block under all operating conditions. The support arrangement also is operative to accommodate a substantial difference in thermal expansion between the ceramic liner components of the combustor and the metal material of the engine block.
Ochoa-González, R; Córdoba, P; Díaz-Somoano, M; Font, O; López-Antón, M A; Leiva, C; Martínez-Tarazona, M R; Querol, X; Pereira, C Fernández; Tomás, A; Gómez, P; Mesado, P
2011-10-01
This paper evaluates the speciation and partitioning of mercury in two Spanish pulverised coal combustion power plants (PP1 and PP2), equipped with wet limestone-based flue gas desulphurisation facilities (FGD) operating with forced oxidation and re-circulation of FGD water streams. These plants are fed with coal (PP1) and coal/pet-coke blends (PP2) with different mercury contents. The behaviour, partitioning and speciation of Hg were found to be similar during the combustion processes but different in the FGD systems of the two power plants. A high proportion (86-88%) of Hg escaped the electrostatic precipitator in gaseous form, Hg2+ being the predominant mercury species (68-86%) to enter the FGD. At this point, a relatively high total Hg retention (72% and 65%) was achieved in the PP1 and PP2 (2007) FGD facilities respectively. However, during the second sampling campaign for PP2 (2008), the mercury removal achieved by the FGD was much lower (26%). Lab-scale tests point to liquid/gas ratio as the main parameter affecting oxidised mercury capture in the scrubber. The partitioning of the gaseous mercury reaching the FGD system in the wastes and by-products differed. In the low mercury input power plant (PP1) most of the mercury (67%) was associated with the FGD gypsum. Moreover in PP2 a significant proportion of the gaseous mercury reaching the FGD system remained in the aqueous phase (45%) in the 2007 sampling campaign while most of it escaped in 2008 (74%). This may be attributed to the scrubber operating conditions and the different composition and chemistry of the scrubber solution probably due to the use of an additive. Copyright © 2011 Elsevier Ltd. All rights reserved.
He, Chiyang; Zhu, Zaifang; Gu, Congying; Lu, Joann; Liu, Shaorong
2012-03-02
Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet and outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (∼3100 psi). We further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides. Copyright © 2012 Elsevier B.V. All rights reserved.
He, Chiyang; Zhu, Zaifang; Gu, Congying; ...
2012-01-09
Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet andmore » outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (~3100 psi). Here, we further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides.« less
Flue gas desulfurization method and apparatus
Madden, D.A.; Farthing, G.A.
1998-08-18
A combined furnace limestone injection and dry scrubber flue gas desulfurization (FGD) system collects solids from the flue gas stream in first particulate collection device located downstream of an outlet of a convection pass of the furnace and upstream of the dry scrubber. The collected solids are diverted to the dry scrubber feed slurry preparation system to increase sulfur oxide species removal efficiency and sorbent utilization. The level of lime in the feed slurry provided to the dry scrubber is thus increased, which enhances removal of sulfur oxide species in the dry scrubber. The decreased particulate loading to the dry scrubber helps maintain a desired degree of free moisture in the flue gas stream entering the dry scrubber, which enhances sulfur oxide species removal both in the dry scrubber and downstream particulate collector, normally a baghouse. 5 figs.
Flue gas desulfurization method and apparatus
Madden, D.A.; Farthing, G.A.
1998-09-29
A combined furnace limestone injection and dry scrubber flue gas desulfurization (FGD) system collects solids from the flue gas stream in first particulate collection device located downstream of an outlet of a convection pass of the furnace and upstream of the dry scrubber. The collected solids are diverted to the dry scrubber feed slurry preparation system to increase sulfur oxide species removal efficiency and sorbent utilization. The level of lime in the feed slurry provided to the dry scrubber is thus increased, which enhances removal of sulfur oxide species in the dry scrubber. The decreased particulate loading to the dry scrubber helps maintain a desired degree of free moisture in the flue gas stream entering the dry scrubber, which enhances sulfur oxide species removal both in the dry scrubber and downstream particulate collector, normally a baghouse. 5 figs.
Daubon, Thomas; Buccione, Roberto; Génot, Elisabeth
2011-01-01
Podosomes are dynamic actin-rich adhesion plasma membrane microdomains endowed with extracellular matrix-degrading activities. In aortic endothelial cells, podosomes are induced by transforming growth factor β (TGF-β), but how this occurs is largely unknown. It is thought that, in endothelial cells, podosomes play a role in vessel remodeling and/or in breaching anatomical barriers. We demonstrate here that, in bovine aortic endothelial cells, that the Cdc42-specific guanine exchange factor (GEF) Fgd1 is expressed and regulated by TGF-β to induce Cdc42-dependent podosome assembly. Within 15 min of TGF-β stimulation, Fgd1, but none of the other tested Cdc42 GEFs, undergoes tyrosine phosphorylation, associates with Cdc42, and translocates to the subcortical cytoskeleton via a cortactin-dependent mechanism. Small interfering RNA-mediated Fgd1 knockdown inhibits TGF-β-induced Cdc42 activation. Fgd1 depletion also reduces podosome formation and associated matrix degradation and these defects are rescued by reexpression of Fgd1. Although overexpression of Fgd1 does not promote podosome formation per se, it enhances TGF-β-induced matrix degradation. Our results identify Fgd1 as a TGF-β-regulated GEF and, as such, the first GEF to be involved in the process of cytokine-induced podosome formation. Our findings reveal the involvement of Fgd1 in endothelial cell biology and open up new avenues to study its role in vascular pathophysiology. PMID:21911474
Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Pilot-Scale Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary M. Blythe
2006-03-01
This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, ''Field Testing of a Wet FGD Additive.'' The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemissions of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate that the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project will conduct pilot and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosage requirements to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB co-fired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot and full-scale jet bubbling reactor (JBR) FGD systems to be tested. A third utility, to be named later, will provide the high-sulfur Eastern bituminous coal full-scale FGD test site. Degussa Corporation is providing the TMT-15 additive and technical support to the test program. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High Sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. This topical report presents the results from the Task 2 and Task 4 pilot-scale additive tests. The Task 3 and Task 5 full-scale additive tests will be conducted later in calendar year 2006.« less
Chen, Qun; Wang, Shujuan; Li, Yan; Zhang, Ning; Zhao, Bo; Zhuo, Yuqun; Chen, Changhe
2015-01-01
Abstract Although flue gas desulfurization (FGD) gypsum has become an effective soil amendment for sodic soil reclamation, it carries extra heavy metal contamination into the soil environment. The fate of heavy metals introduced by FGD gypsum in sodic or saline–alkali soils is still unclear. This work aims to investigate the effects of FGD gypsum addition on the heavy metal distributions in a sodic soil. Original soil samples were collected from typical sodic land in north China. Soil column leaching tests were conducted to investigate the influence of FGD gypsum addition on the soil properties, especially on distribution profiles of the heavy metals (Pb, Cd, Cr, As, and Hg) in the soil layers. Results showed that pH, electrical conductivity, and exchangeable sodium percentage in amended soils were significantly reduced from 10.2 to 8.46, 1.8 to 0.2 dS/m, and 18.14% to 1.28%, respectively. As and Hg concentrations in the soils were found to be positively correlated with FGD gypsum added. The amount of Hg in the leachate was positively correlated with FGD gypsum application ratio, whereas a negative correlation was observed between the Pb concentration in the leachate and the FGD gypsum ratio. Results revealed that heavy metal concentrations in soils complied well with Environmental Quality Standard for Soils in China (GB15618-1995). This work helps to understand the fate of FGD gypsum-introduced heavy metals in sodic soils and provides a baseline for further environmental risk assessment associated with applying FGD gypsum for sodic soil remediation. PMID:26064038
Chen, Qun; Wang, Shujuan; Li, Yan; Zhang, Ning; Zhao, Bo; Zhuo, Yuqun; Chen, Changhe
2015-06-01
Although flue gas desulfurization (FGD) gypsum has become an effective soil amendment for sodic soil reclamation, it carries extra heavy metal contamination into the soil environment. The fate of heavy metals introduced by FGD gypsum in sodic or saline-alkali soils is still unclear. This work aims to investigate the effects of FGD gypsum addition on the heavy metal distributions in a sodic soil. Original soil samples were collected from typical sodic land in north China. Soil column leaching tests were conducted to investigate the influence of FGD gypsum addition on the soil properties, especially on distribution profiles of the heavy metals (Pb, Cd, Cr, As, and Hg) in the soil layers. Results showed that pH, electrical conductivity, and exchangeable sodium percentage in amended soils were significantly reduced from 10.2 to 8.46, 1.8 to 0.2 dS/m, and 18.14% to 1.28%, respectively. As and Hg concentrations in the soils were found to be positively correlated with FGD gypsum added. The amount of Hg in the leachate was positively correlated with FGD gypsum application ratio, whereas a negative correlation was observed between the Pb concentration in the leachate and the FGD gypsum ratio. Results revealed that heavy metal concentrations in soils complied well with Environmental Quality Standard for Soils in China (GB15618-1995). This work helps to understand the fate of FGD gypsum-introduced heavy metals in sodic soils and provides a baseline for further environmental risk assessment associated with applying FGD gypsum for sodic soil remediation.
Analysis of Flue Gas Desulfurization (FGD) Processes for Potential Use on Army Coal-Fired Boilers
1980-09-01
TECHNICAL REPORT N-93 September 1980 ANALYSIS OF FLUE GAS DESULFURIZATION (FGD) PROCESSES FOR POTENTIAL USE ON ARMY COAL-FIRED BOILERS TECHNICAL LIBRARY...REFERENCE: Technical Report N-93, Analysis of Flue Gas Desulfurization (FGD) Ppooesses for Potential Use on Army Coal-Fired Boilers Please take a few...REPORT DOCUMENTATION PAGE 1. REPORT NUMBER CERL-TR-N-93 2. GOVT ACCESSION NO «. TITLE (end Subtitle) ANALYSIS OF FLUE GAS DESULFURIZATION (FGD
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
40 CFR 60.717 - Reporting and monitoring requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...
40 CFR 60.717 - Reporting and monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...
40 CFR 60.717 - Reporting and monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...
40 CFR 60.717 - Reporting and monitoring requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...
40 CFR 60.717 - Reporting and monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in § 60.713(b)(1) (liquid material balance); (2) The VOC contained in the coatings for the... monitoring only the carbon adsorption system outlet concentration levels of organic compounds, the periods.... (i) For carbon adsorption systems with a common exhaust stack for all the individual adsorber vessels...
SO2 SCRUBBING TECHNOLOGIES: A REVIEW
The paper gives results of a review of commercially available flue gas desulfurization (FGD) technologies that have an established record of performance. Data on worldwide FGD applications reflect that wet FGD technologies have been used at most of the installations. Among the ...
Capturing CO2 from Coal-Fired Power Plants: Challenges for a Comprehensive Strategy
2008-08-15
efficient flue gas desulfurization (FGD) or selective catalytic reduction (SCR) devices (or none), requiring either upgrading of existing FGD and SCR...saturated flue Figure 6. CO2 Price Projections CRS-16 42 Donald Shattuck, et al., A History of Flue Gas Desulfurization (FGD) — The Early Years, UE Technical...available in both the eastern and western parts of the United States, or by the use of emerging flue gas desulfurization (FGD) devices.46 At the time
Porter, Chad K; Gormley, Robert; Tribble, David R; Cash, Brooks D; Riddle, Mark S
2011-01-01
Functional gastrointestinal disorders (FGDs) are recognized sequelae of infectious gastroenteritis (IGE). Within the active duty military population, a group with known high IGE rates, the population-based incidence, risk factors, and attributable burden of care referable to FGD after IGE are poorly defined. Using electronic medical encounter data (1999-2007) on active duty US military, a matched, case-control study describing the epidemiology and risk determinants of FGD (irritable bowel syndrome (IBS), functional constipation (FC), functional diarrhea (FD), dyspepsia (D)) was conducted. Incidence rates and duration of FGD-related medical care were estimated, and conditional logistic regression was utilized to evaluate FGD risk after IGE. A total of 31,866 cases of FGD identified were distributed as follows: FC 55% (n=17,538), D 21.2% (n=6,750), FD 2.1% (n=674), IBS 28.5% (n=9,091). Previous IGE episodes were distributed as follows: specific bacterial pathogen (n=65, 1.2%), bacterial, with no pathogen specified (n=2155, 38.9%), protozoal (n=38, 0.7%), viral (n=3431, 61.9%). A significant association between IGE and all FGD (odds ratio (OR) 2.64; P<0.001) was seen, with highest risk for FD (OR 6.28, P<0.001) and IBS (OR 3.72, P<0.001), and moderate risk for FC (2.15, P<0.001) and D (OR 2.39, P<0.001). Risk generally increased with temporal proximity to, and bacterial etiology of, exposure. Duration of FGD-related care was prolonged with 22.7% having FGD-associated medical encounters 5 years after diagnosis. FGD are common in this population at high risk for IGE. When considering effective countermeasures and mitigation strategies, attention directed toward prevention as well as the acute and chronic sequelae of these infections is needed.
Devanarayana, Niranga Manjuri; Mettananda, Sachith; Liyanarachchi, Chathurangi; Nanayakkara, Navoda; Mendis, Niranjala; Perera, Nimnadi; Rajindrajith, Shaman
2011-12-01
Functional gastrointestinal disorders (FGD) are common among children, but little is known regarding their prevalence in developing countries. We assessed the prevalence of abdominal pain-predominant FGD, in addition to the predisposing factors and symptomatology, in Sri Lankan children. A cross-sectional survey was conducted among a randomly selected group of 10- to 16-year-olds in 8 randomly selected schools in 4 provinces in Sri Lanka. A validated, self-administered questionnaire was completed by children independently in an examination setting. FGD were diagnosed using Rome III criteria. A total of 2180 questionnaires were distributed and 2163 (99.2%) were included in the analysis (1189 [55%] boys, mean age 13.4 years, standard deviation 1.8 years). Of them, 270 (12.5%) had at least 1 abdominal pain-predominant FGD. Irritable bowel syndrome (IBS) was seen in 107 (4.9%), functional dyspepsia in 54 (2.5%), functional abdominal pain in 96 (4.4%), and abdominal migraine (AM) in 21 (1.0%) (2 had AM and functional dyspepsia, 6 had AM and IBS). Extraintestinal symptoms were more common among affected children (P < 0.05). Abdominal pain-predominant FGD were higher in girls and those exposed to stressful events (P < 0.05). Prevalence negatively correlated with age (r = -0.05, P = 0.02). Abdominal pain-predominant FGD affects 12.5% of children ages 10 to 16 years and constitutes a significant health problem in Sri Lanka. IBS is the most common FGD subtype present. Abdominal pain-predominant FGD are higher in girls and those exposed to emotional stress. Prevalence of FGD decreased with age. Extraintestinal symptoms are more frequent in affected children.
STATUS OF COMMERCIAL UTILITY FGD (FLUE GAS DESULFURIZATION) TECHNOLOGY
The paper summarizes the status of FGD technology as of March 1983 and highlights recent trends in process selection, design, and performance of FGD systems. The information collected in the program is stored in the Flue Gas Desulfurization Information System (FGDIS), a collectio...
Application study of Bio-FGD based on environmental safety during the coal combustion
NASA Astrophysics Data System (ADS)
Zhang, Pin
2018-05-01
Coal combustion produces a large amount of acidic gas, which is the main cause of acid rain and other natural disasters. Flue Gas Desulfurization (FGD) is a necessary requirement for clean coal combustion. Compared with the traditional chemical desulfurization technology, biological desulfurization has the advantages of low operating cost, without secondary pollution, low carbon emission and the additional economic benefits. The process and structure of BioDeSOx which as one of Bio-FGD technology is introduced. The major factors that influent BioDeSOx Bio- FGD system is the pH, oxidation reduction potential (-300 MV to -400MV), electrical conductivity, the adding amount of nutrient and temperature (30°C-40°C). Taking the Bio- FGD project of Yixing xielian thermal power plant as an example, the BioDeSOx technology was applied in this project. The environmental and economic benefits of the project were greater than the traditional desulfurization technology. With the continuous improvement of environmental safety standards, Bio- FGD technology will have broad application prospects.
Use Of limestone resources in flue-gas desulfurization power plants in the Ohio River Valley
Foose, M.P.; Barsotti, A.F.
1999-01-01
In 1994, more than 41 of the approximately 160 coal-fired, electrical- power plants within the six-state Ohio River Valley region used flue-gas desulfurization (FGD) units to desulfurize their emissions, an approximately 100% increase over the number of plants using FGD units in 1989. This increase represents a trend that may continue with greater efforts to meet Federal Clean Air Act standards. Abundant limestone resources exist in the Ohio River Valley and are accessed by approximately 975 quarries. However, only 35 of these are believed to have supplied limestone for FGD electrical generating facilities. The locations of these limestone suppliers do not show a simple spatial correlation with FGD facilities, and the closest quarries are not being used in most cases. Thus, reduction in transportation costs may be possible in some cases. Most waste generated by FGD electrical-generating plants is not recycled. However, many FGD sites are relatively close to gypsum wallboard producers that may be able to process some of their waste.
Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 5 Full-Scale Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary Blythe; MariJon Owens
2007-12-01
This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from the FGD liquor and bulkmore » solid byproducts for separate disposal. The project is conducting pilot- and full-scale tests of the additives in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power has provided the Texas lignite/PRB co-fired test site for pilot FGD tests and cost sharing. Southern Company has provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation is providing the TMT-15 additive, and the Nalco Company is providing the Nalco 8034 additive. Both companies are also supplying technical support to the test program as in-kind cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High-sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Plant Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. The pilot-scale tests and the full-scale test using high-sulfur coal were completed in 2005 and 2006 and have been previously reported. This topical report presents the results from the Task 5 full-scale additive tests, conducted at Southern Company's Plant Yates Unit 1. Both additives were tested there.« less
Field Testing of a Wet FGD Additive for Enhanced Mercury Control - Task 3 Full-scale Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary Blythe
2007-05-01
This Topical Report summarizes progress on Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project is to demonstrate the use of a flue gas desulfurization (FGD) additive, Degussa Corporation's TMT-15, to prevent the reemission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project intends to demonstrate whether the additive can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine TMT salt that can be separated from the FGD liquor and bulk solid byproducts for separate disposal.more » The project is conducting pilot- and full-scale tests of the TMT-15 additive in wet FGD absorbers. The tests are intended to determine required additive dosages to prevent Hg{sup 0} reemissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Power River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, TXU Generation Company LP, Southern Company, and Degussa Corporation. TXU Generation has provided the Texas lignite/PRB cofired test site for pilot FGD tests, Monticello Steam Electric Station Unit 3. Southern Company is providing the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, as well as the pilot- and full-scale jet bubbling reactor (JBR) FGD systems to be tested. IPL, an AES company, provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Degussa Corporation is providing the TMT-15 additive and technical support to the test program as cost sharing. The project is being conducted in six tasks. Of the six project tasks, Task 1 involves project planning and Task 6 involves management and reporting. The other four tasks involve field testing on FGD systems, either at pilot or full scale. The four tasks include: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High-sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Plant Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. The pilot-scale tests were completed in 2005 and have been previously reported. This topical report presents the results from the Task 3 full-scale additive tests, conducted at IPL's Petersburg Station Unit 2. The Task 5 full-scale additive tests will be conducted later in calendar year 2007.« less
Sustainable Uses of FGD Gypsum in Agricultural Systems: Introduction.
Watts, Dexter B; Dick, Warren A
2014-01-01
Interest in using gypsum as a management tool to improve crop yields and soil and water quality has recently increased. Abundant supply and availability of flue gas desulfurization (FGD) gypsum, a by-product of scrubbing sulfur from combustion gases at coal-fired power plants, in major agricultural producing regions within the last two decades has attributed to this interest. Currently, published data on the long-term sustainability of FGD gypsum use in agricultural systems is limited. This has led to organization of the American Society of Agronomy's Community "By-product Gypsum Uses in Agriculture" and a special collection of nine technical research articles on various issues related to FGD gypsum uses in agricultural systems. A brief review of FGD gypsum, rationale for the special collection, overviews of articles, knowledge gaps, and future research directions are presented in this introductory paper. The nine articles are focused in three general areas: (i) mercury and other trace element impacts, (ii) water quality impacts, and (iii) agronomic responses and soil physical changes. While this is not an exhaustive review of the topic, results indicate that FGD gypsum use in sustainable agricultural production systems is promising. The environmental impacts of FGD gypsum are mostly positive, with only a few negative results observed, even when applied at rates representing cumulative 80-year applications. Thus, FGD gypsum, if properly managed, seems to represent an important potential input into agricultural systems. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization gypsum (FGD-gypsum), a byproduct from coal fired electricity generators, has the potential for beneficial use in agricultural systems as a soil amendment. Similar to mined gypsum it can improve soil chemical and physical properties and increase crop productivity. FGD-gypsum ...
Impact of FGD gypsum on soil fertility and plant nutrient uptake
USDA-ARS?s Scientific Manuscript database
Use of FGD gypsum is thought to improve soil productivity and increase plant production. Thus, a study was conducted to evaluate the effects of FGD gypsum on yield, plant nutrient uptake and soil productivity. The study was conducted on an established bermudagrass pasture. Poultry litter was applied...
Influence Of Coal Combustion Flue Gas Desulfurization Waste On Element Uptake By Maize (Zea Mays L.)
DOE Office of Scientific and Technical Information (OSTI.GOV)
ANNA, KNOX
2005-01-10
A greenhouse study was conducted to determine the effect of coal combustion flue gas desulfurization (FGD) waste from a coal combustion electric power facility on element uptake by maize (Zea mays L.). Unweathered FGD was applied to an Orangeburg Series (Typic Paleudult) soil with an initial soil pH salt of 4.90. The FGD was added at 0, 1, 2, 4, 6, 8, and 10 per cent by weight. The test plant, maize, was harvested after 6 weeks of growth. Within 56 days of the FGD application, all rates of FGD significantly increased pH in the soil and the soil leachatemore » above 6.0. The elemental concentration of the maize tissues indicated a characteristic elevation of B, Se, Mo, and As. However, no visual symptoms of toxicity of B or other elements in plants were observed. Increasing level of FGD caused a steady decline in dry weight, with the highest treatment producing plants which had approximately half the biomass of the control plants. Due to elevated concentrations of B and other elements and due to adverse yield effects measured on plants, unweathered FGD would not be a suitable amendment for 6-week old maize on this soil.« less
Field Testing of a Wet FGD Additive for Enhanced Mercury Control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gary Blythe; MariJon Owens
2007-12-31
This document is the final report for DOE-NETL Cooperative Agreement DE-FC26-04NT42309, 'Field Testing of a Wet FGD Additive'. The objective of the project has been to demonstrate the use of two flue gas desulfurization (FGD) additives, Evonik Degussa Corporation's TMT-15 and Nalco Company's Nalco 8034, to prevent the re-emission of elemental mercury (Hg{sup 0}) in flue gas exiting wet FGD systems on coal-fired boilers. Furthermore, the project was intended to demonstrate whether such additives can be used to precipitate most of the mercury (Hg) removed in the wet FGD system as a fine salt that can be separated from themore » FGD liquor and bulk solid byproducts for separate disposal. The project involved pilot- and full-scale tests of the additives in wet FGD absorbers. The tests were intended to determine required additive dosages to prevent Hg{sup 0} re-emissions and to separate mercury from the normal FGD byproducts for three coal types: Texas lignite/Powder River Basin (PRB) coal blend, high-sulfur Eastern bituminous coal, and low-sulfur Eastern bituminous coal. The project team consists of URS Group, Inc., EPRI, Luminant Power (was TXU Generation Company LP), Southern Company, IPL (an AES company), Evonik Degussa Corporation and the Nalco Company. Luminant Power provided the Texas lignite/PRB co-fired test site for pilot FGD tests and project cost sharing. Southern Company provided the low-sulfur Eastern bituminous coal host site for wet scrubbing tests, the pilot- and full-scale jet bubbling reactor (JBR) FGD systems tested, and project cost sharing. IPL provided the high-sulfur Eastern bituminous coal full-scale FGD test site and cost sharing. Evonik Degussa Corporation provided the TMT-15 additive, and the Nalco Company provided the Nalco 8034 additive. Both companies also supplied technical support to the test program as in-kind cost sharing. The project was conducted in six tasks. Of the six tasks, Task 1 involved project planning and Task 6 involved management and reporting. The other four tasks involved field testing on FGD systems, either at pilot or full scale. These four tasks included: Task 2 - Pilot Additive Testing in Texas Lignite Flue Gas; Task 3 - Full-scale FGD Additive Testing in High-sulfur Eastern Bituminous Flue Gas; Task 4 - Pilot Wet Scrubber Additive Tests at Plant Yates; and Task 5 - Full-scale Additive Tests at Plant Yates. The pilot-scale tests were completed in 2005 and the full-scale test using high-sulfur coal was completed in 2006; only the TMT-15 additive was tested in these efforts. The Task 5 full-scale additive tests conducted at Southern Company's Plant Yates Unit 1 were completed in 2007, and both the TMT-15 and Nalco 8034 additives were tested.« less
Use of FGD gypsum on a bermudagrass pasture in the Appalachian Plateau Region
USDA-ARS?s Scientific Manuscript database
Addition of industrial by-products from coal fired power plants (FGD gypsum and FGD gypsum + fly ash) are thought to increase plant production. Thus, a study was conducted to evaluate the effects of industrial by-products as a soil amendment on bermudagrass (Cynodon dactylon L.) yield. The study was...
Key issues for low-cost FGD installations
DOE Office of Scientific and Technical Information (OSTI.GOV)
DePriest, W.; Mazurek, J.M.
1995-12-01
This paper will discuss various methods for installing low-cost FGD systems. The paper will include a discussion of various types of FGD systems available, both wet and dry, and will compare the relative cost of each type. Important design issues, such as use of spare equipment, materials of construction, etc. will be presented. An overview of various low-cost construction techniques (i.e., modularization) will be included. This paper will draw heavily from Sargent & Lundy`s database of past and current FGD projects together with information we gathered for several Electric Power Research Institute (EPRI) studies on the subject.
Modeling and optimization of the air system in polymer exchange membrane fuel cell systems
NASA Astrophysics Data System (ADS)
Bao, Cheng; Ouyang, Minggao; Yi, Baolian
Stack and air system are the two most important components in the fuel cell system (FCS). It is meaningful to study their properties and the trade-off between them. In this paper, a modified one-dimensional steady-state analytical fuel cell model is used. The logarithmic mean of the inlet and the outlet oxygen partial pressure is adopted to avoid underestimating the effect of air stoichiometry. And the pressure drop model in the grid-distributed flow field is included in the stack analysis. Combined with the coordinate change preprocessing and analog technique, neural network is used to treat the MAP of compressor and turbine in the air system. Three kinds of air system topologies, the pure screw compressor, serial booster and exhaust expander are analyzed in this article. A real-code genetic algorithm is programmed to obtain the global optimum air stoichiometric ratio and the cathode outlet pressure. It is shown that the serial booster and expander with the help of exhaust recycling, can improve more than 3% in the FCS efficiency comparing to the pure screw compressor. As the net power increases, the optimum cathode outlet pressure keeps rising and the air stoichiometry takes on the concave trajectory. The working zone of the proportional valve is also discussed. This presented work is helpful to the design of the air system in fuel cell system. The steady-state optimum can also be used in the dynamic control.
Use of FGD gypsum to reduce p loss from agricultural fields
USDA-ARS?s Scientific Manuscript database
Controlling P loss from agricultural fields has become a major issue in recent years, especially in areas where manure is used as nutrient sources. It is believed that FGD gypsum can be used as a management practice to reduce soluble P loss. Thus, the objective of this study was to determine FGD gy...
Córdoba, Patricia; Castro, Iria; Maroto-Valer, Mercedes; Querol, Xavier
2015-06-01
Experimental and geochemical modelling studies were carried out to identify mineral and solid phases containing major, minor, and trace elements and the mechanism of the retention of these elements in Flue Gas Desulphurisation (FGD)-gypsum samples from a coal-fired power plant under filtered water recirculation to the scrubber and forced oxidation conditions. The role of the pH and related environmental factors on the mobility of Li, Ni, Zn, As, Se, Mo, and U from FGD-gypsums for a comprehensive assessment of element leaching behaviour were also carried out. Results show that the extraction rate of the studied elements generally increases with decreasing the pH value of the FGD-gypsum leachates. The increase of the mobility of elements such as U, Se, and As in the FGD-gypsum entails the modification of their aqueous speciation in the leachates; UO2SO4, H2Se, and HAsO2 are the aqueous complexes with the highest activities under acidic conditions. The speciation of Zn, Li, and Ni is not affected in spite of pH changes; these elements occur as free cations and associated to SO4(2) in the FGD-gypsum leachates. The mobility of Cu and Mo decreases by decreasing the pH of the FGD-gypsum leachates, which might be associated to the precipitation of CuSe2 and MoSe2, respectively. Time-of-Flight mass spectrometry of the solid phase combined with geochemical modelling of the aqueous phase has proved useful in understanding the mobility and geochemical behaviour of elements and their partitioning into FGD-gypsum samples. Copyright © 2015. Published by Elsevier B.V.
Conversion of waste FGD gypsum into hydroxyapatite for removal of Pb²⁺ and Cd²⁺ from wastewater.
Yan, Yubo; Dong, Xiaoli; Sun, Xiaolei; Sun, Xiuyun; Li, Jiansheng; Shen, Jinyou; Han, Weiqing; Liu, Xiaodong; Wang, Lianjun
2014-09-01
Flue gas desulfurization (FGD) gypsum, a familiar waste generated from coal-fired power plants, was successfully transformed to hydroxyapatite (FGD-HAP) by hydrothermal method. The obtained FGD-HAP was characterized by XRD, FTIR, TEM and BET methods and investigated as adsorbent for removal of Pb(2+) and Cd(2+) from wastewater. Batch experiments were performed by varying the pH values, contact time and initial metal concentration. The result of pH impact showed that the adsorption of two ions was pH dependent process, and the pH 5.0-6.0 was found to be the optimum condition. The achieved experimental data were analyzed with various kinetic and isotherm models. The kinetic studies displayed that the pseudo-second order kinetic model could describe adsorption processes well with high correlation coefficient, and the Langmuir isotherm model provided the best fit to the equilibrium experimental data. The maximum adsorption capacities calculated from Langmuir equation were 277.8 and 43.10mg/g for Pb(2+) and Cd(2+), respectively, which can compete with other adsorbents. The thermodynamic parameters revealed the adsorption processes were endothermic and spontaneous in nature. In binary adsorption, the amount of Cd(2+) adsorbed on FGD-HAP decreased by 46.0% with increasing concentration of Pb(2+), which was higher than that of Pb(2+)(21.7%), demonstrating the stronger affinity between FGD-HAP and Pb(2+). The highest amount of Pb(2+) and Cd(2+) desorbed from saturated FGD-HAP by EDTA solution confirmed the FGD-HAP was a promising alternative adsorbent in treatment of toxic Pb(2+) and Cd(2+) wastewater. Copyright © 2014 Elsevier Inc. All rights reserved.
Devanarayana, Niranga Manjuri; Rajindrajith, Shaman; Benninga, Marc A
2014-08-21
Abdominal pain predominant functional gastrointestinal diseases (AP-FGD) are commonly seen in the paediatric age group. It has significant impact on daily activities of affected children. Main objective of this study was to assess the health related quality of life (HRQoL) in children with AP-FGD. This was a cross sectional survey conducted in children aged 13-18 years, in four randomly selected schools in Western province of Sri Lanka. Data was collected using a previously validated, self-administered questionnaire. It had questions on symptoms, HRQoL and health care consultation. AP-FGD were diagnosed using Rome III criteria. A total of 1850 questionnaires were included in the analysis [males 1000 (54.1%), mean age 14.4 years and SD 1.3 years]. Of them, 305 (16.5%) had AP-FGD [irritable bowel syndrome = 91(4.9%), functional dyspepsia = 11 (0.6%), abdominal migraine = 37 (1.9%) and functional abdominal pain = 180 (9.7%)]. Lower HRQoL scores for physical (83.6 vs. 91.4 in controls), social (85.0 vs. 92.7), emotional (73.6 vs. 82.7) and school (75.0 vs. 82.5) functioning domains, and lower overall scores (79.6 vs. 88.0) were seen in children with AP-FGD (p < 0.001). A weak but significant negative correlation was observed between HRQoL score and severity of abdominal pain (r = -0.24, p < 0.0001). Eighty five children (27.9%) had sought healthcare for AP-FGD. Factors determining healthcare seeking were presence of abdominal bloating and vomiting (p < 0.05). Children with AP-FGD have lower quality of life in all 4 domains. Those with severe symptoms have lower HRQoL. Approximately 28% of children with AP-FGD seek healthcare for their symptoms.
Predicting the Performance of an Axial-Flow Compressor
NASA Technical Reports Server (NTRS)
Steinke, R. J.
1986-01-01
Stage-stacking computer code (STGSTK) developed for predicting off-design performance of multi-stage axial-flow compressors. Code uses meanline stagestacking method. Stage and cumulative compressor performance calculated from representative meanline velocity diagrams located at rotor inlet and outlet meanline radii. Numerous options available within code. Code developed so user modify correlations to suit their needs.
NASA Technical Reports Server (NTRS)
Steinke, R. J.
1982-01-01
A FORTRAN computer code is presented for off-design performance prediction of axial-flow compressors. Stage and compressor performance is obtained by a stage-stacking method that uses representative velocity diagrams at rotor inlet and outlet meanline radii. The code has options for: (1) direct user input or calculation of nondimensional stage characteristics; (2) adjustment of stage characteristics for off-design speed and blade setting angle; (3) adjustment of rotor deviation angle for off-design conditions; and (4) SI or U.S. customary units. Correlations from experimental data are used to model real flow conditions. Calculations are compared with experimental data.
In 2007, 12.3 million tons of flue gas desulfurization (FGD) gypsum was produced due to air emission controls at coal-fired power plants. With increasing use of wet scrubbers in response to more stringent air pollution control requirements, FGD gypsum production is expected to in...
[Multimodal therapy of functional gastrointestinal disorders].
Egloff, N; Beer, C; Gschossmann, J M; Sendensky, A; von Känel, R
2010-04-14
A multimodal approach is state-of-the art for effective treatment of functional gastrointestinal disorders (FGD) like irritable bowel syndrome and functional dyspepsia. Based on the now established view that the pathogenesis of FGD is multicausal, evidence-based therapeutic options comprise education about the nature of the disorder, dietary modifications, relaxation techniques, behavioral changes, and pharmacological treatments. These therapies are variously combined depending on the severity of the FGD and the individual needs of the patient. Our overview portrays the options for the therapy of FGD and proposes that these are best provided by an interdisciplinary team of primary care physicians, gastroenterologists, and psychosomatic medicine specialists.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, E.C.
2005-09-30
According to ACAA's 'Coal combustion production and user survey' covering 2003, FGD gypsum utilization in the USA has risen to 70% but with 12 m tons being produced annually there is great opportunity to expand its use in producing wallboard (its primary use) and also in cement and concrete products and agriculture. In 2003 less than 1 mt of FGD gypsum was sold into these latter markets. Although nearly all the 12 newest wallboard plants announced since 1995 have been designed to use this material, only 27% of total gypsum wallboard production in the USA utilizes FGD gypsum. 1 ref.,more » 2 figs., 2 photos.« less
Microbial communities associated with wet flue gas desulfurization systems
Brown, Bryan P.; Brown, Shannon R.; Senko, John M.
2012-01-01
Flue gas desulfurization (FGD) systems are employed to remove SOx gasses that are produced by the combustion of coal for electric power generation, and consequently limit acid rain associated with these activities. Wet FGDs represent a physicochemically extreme environment due to the high operating temperatures and total dissolved solids (TDS) of fluids in the interior of the FGD units. Despite the potential importance of microbial activities in the performance and operation of FGD systems, the microbial communities associated with them have not been evaluated. Microbial communities associated with distinct process points of FGD systems at several coal-fired electricity generation facilities were evaluated using culture-dependent and -independent approaches. Due to the high solute concentrations and temperatures in the FGD absorber units, culturable halothermophilic/tolerant bacteria were more abundant in samples collected from within the absorber units than in samples collected from the makeup waters that are used to replenish fluids inside the absorber units. Evaluation of bacterial 16S rRNA genes recovered from scale deposits on the walls of absorber units revealed that the microbial communities associated with these deposits are primarily composed of thermophilic bacterial lineages. These findings suggest that unique microbial communities develop in FGD systems in response to physicochemical characteristics of the different process points within the systems. The activities of the thermophilic microbial communities that develop within scale deposits could play a role in the corrosion of steel structures in FGD systems. PMID:23226147
77 FR 3712 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Regional Haze
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-25
... equal incremental change in visibility perceived by the human eye. Most people can detect a change in... desulfurization (FGD), semi-dry FGD, and over-fire air (OFA) with a sorbent injection system (SIS). Ohio and MPRO... on up to 7 days a year. Ohio selected semi-dry FGD as the BART SO 2 control, which is expected to...
Application Potential of Energy Systems at Navy Sites. Volume I. Methodology and Results.
1980-01-01
see Table 5-4). Flue gas desulfurization (FGD), electrostatic precipitators (ESP), and staged combustion (SC) were selected to control SOX...energy sources are required to meet proposed Federal Stationary Source Standards. Flue gas desulfurization (FGD), electrostatic precipitators (ESP...pollution control equipment follows: * FGD -- Flue gas from the furnace is passed counter-currently through a limestone (CaCO3) slurry which reacts with
Landslide remediation on Ohio State Route 83 using clean coal combustion by-products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Payette, R.; Chen, Xi You; Wolfe, W.
1995-12-31
The disposal of flue gas desulfurization (FGD) by-products has become a major concern as issues of emission cleansing and landfill costs continue to rise. Laboratory tests conducted at the Ohio State University have shown that dry FGD by-products possess certain engineering properties that have proven desirable in a number of construction uses. As a follow on to the laboratory program, a field investigation into engineering uses of dry FGD wastes was initiated. In the present work, an FGD by-product was used to reconstruct the failed portion of a highway embankment. The construction process and the stability of the repaired embankmentmore » are examined.« less
40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests
Code of Federal Regulations, 2013 CFR
2013-07-01
... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...
40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests
Code of Federal Regulations, 2010 CFR
2010-07-01
... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...
40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests
Code of Federal Regulations, 2011 CFR
2011-07-01
... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...
40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests
Code of Federal Regulations, 2012 CFR
2012-07-01
... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...
40 CFR Table 4 to Subpart Sssss to... - Requirements for Performance Tests
Code of Federal Regulations, 2014 CFR
2014-07-01
... OM&M plan; and (6) If complying with the THC concentration or THC percentage reduction limits... continuous process unit that is subject to the THC emission limit listed in item 2.a., 3.a., 4, or 5 of Table 1 to this subpart a. Measure THC concentrations at the outlet of the control device or in the stack...
Investigation of a mercury speciation technique for flue gas desulfurization materials.
Lee, Joo-Youp; Cho, Kyungmin; Cheng, Lei; Keener, Tim C; Jegadeesan, Gautham; Al-Abed, Souhail R
2009-08-01
Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to benefit from the partial mercury control that these systems provide, some mercury is likely to be bound in with the FGD gypsum and wallboard. In this study, the feasibility of identifying mercury species in the FGD gypsum and wallboard samples was investigated using a large sample size thermal desorption method. Potential candidates of pure mercury standards including mercuric chloride (HgCl2), mercurous chloride (Hg2Cl2), mercury oxide (HgO), mercury sulfide (HgS), and mercuric sulfate (HgSO4) were analyzed to compare their results with those obtained from FGD gypsum and dry wallboard samples. Although any of the thermal evolutionary curves obtained from these pure mercury standards did not exactly match with those of the FGD gypsum and wallboard samples, it was identified that Hg2Cl2 and HgCl2 could be candidates. An additional chlorine analysis from the gypsum and wallboard samples indicated that the chlorine concentrations were approximately 2 orders of magnitude higher than the mercury concentrations, suggesting possible chlorine association with mercury.
FGD Additives to Segregate and Sequester Mercury in Solid Byproducts - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Searcy, K; Bltyhe, G M; Steen, W A
2012-02-28
Many mercury control strategies for U.S. coal-fired power generating plants involve co-benefit capture of oxidized mercury from flue gases treated by wet flue gas desulfurization (FGD) systems. For these processes to be effective at overall mercury control, the captured mercury must not be re-emitted to the atmosphere or into surface or ground water. The project sought to identify scrubber additives and FGD operating conditions under which mercury re-emissions would decrease and mercury would remain in the liquor and be blown down from the system in the chloride purge stream. After exiting the FGD system, mercury would react with precipitating agentsmore » to form stable solid byproducts and would be removed in a dewatering step. The FGD gypsum solids, free of most of the mercury, could then be disposed or processed for reuse as wallboard or in other beneficial reuse. The project comprised extensive bench-scale FGD scrubber tests in Phases I and II. During Phase II, the approaches developed at the bench scale were tested at the pilot scale. Laboratory wastewater treatment tests measured the performance of precipitating agents in removing mercury from the chloride purge stream. Finally, the economic viability of the approaches tested was evaluated.« less
Investigation of a mercury speciation technique for flue gas desulfurization materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J.Y.; Cho K.; Cheng L.
2009-08-15
Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to benefit from the partial mercury control that these systems provide, some mercury is likely to be bound in with the FGD gypsum and wallboard. In this study, the feasibility of identifying mercury species in the FGD gypsum and wallboard samples was investigated using a large sample size thermal desorption method and samples from power plants in Pennsylvania. Potential candidatesmore » of pure mercury standards including mercuric chloride, mercurous chloride, mercury oxide, mercury sulfide, and mercuric sulfate were analyzed to compare their results with those obtained from FGD gypsum and dry wallboard samples. Although any of the thermal evolutionary curves obtained from these pure mercury standards did not exactly match with those of the FGD gypsum and wallboard samples, it was identified that Hg{sub 2}Cl{sub 2} and HgCl{sub 2} could be candidates. An additional chlorine analysis from the gypsum and wallboard samples indicated that the chlorine concentrations were approximately 2 orders of magnitude higher than the mercury concentrations, suggesting possible chlorine association with mercury. 21 refs., 5 figs., 3 tabs.« less
[Irritable bowel syndrome and cardiac right-to-left shunt through a patent foramen ovale].
Alarcón-Fernández, Onofre; Alvarez-Fernández, Jesús-Andrés; Baudet, Juan-Salvador; Pérez-Quintero, Raquel; Sánchez-Del Río, Antonio; Borja-Gutiérrez, Elisa; Borque-Barrera, Pilar
2008-05-31
Both irritable bowel syndrome (IBS) and patent foramen ovale (PFO) have a similar prevalence in the general population, affect more commonly women and are related to comorbidities such as migraine. In IBS there are alterations in the metabolism of certain substances like serotonin. In the presence of PFO with a right- to left-shunt (RLS), a percentage of venous blood bypasses the lung filter and may increase these substances in blood. A phone interview was done to determine the presence of IBS in patients previously attended for detection of RLS with transcranial Doppler ultrasound. The presence and grade of RLS was analyzed and compared with subjects without gastrointestinal symptoms (NoGI). Rome II criteria were used to diagnose IBS or other functional gastrointestinal disorder (FGD) and Venice 1999 consensus were used for the diagnosis of RLS. Thirthy-three (18.3%) of 180 interviewed patients had IBS and 62 (34.4%) other FGD. RLS was found in 41% of NoGI patients, 64% of patients with IBS and 68% of patients with other FGD (odds ratio [OR] = 2.56; p < 0.05 for SII, and OR = 3.06; p < 0.01 for other FGD). RLS with a massive pattern was registered in en 27% of NoGI patients, 39% of patients with IBS and 45% of patients with other FGD (OR = 1.73; p = 1 for IBS, and OR = 2.21; p < 0.05 for other FGD). We found a higher prevalence of cardiac RLS through a PFO in patients with IBS and other FGD. A possible etiopathogenic relationship must be considered in future studies.
Galkaduwa, Madhubhashini B; Hettiarachchi, Ganga M; Kluitenberg, Gerard J; Hutchinson, Stacy L; Davis, Lawrence; Erickson, Larry E
2017-03-01
Constructed wetland treatment systems are used to remove selenium (Se) from flue-gas desulfurization (FGD) wastewater (WW). However, direct confirmation of the mechanism responsible for FGD WW Se retention in soil is lacking. A laboratory-based soil column study was performed to develop an evidence-based mechanism of Se retention and to study the behavior and the retention capacity of FGD WW constituents in water-saturated soil. A deoxygenated 1:1 mixture of FGD WW and raw water was delivered to the columns bottom-up at a flux of 1.68 cm d for 100 d. Some of the columns were flushed with the raw water at the same rate for an additional 100 d. Column effluent was analyzed for constituents of concern. Results showed a complete retention of FGD WW Se in the soil materials. Boron and fluorine were partially retained; however, sulfur, sodium, and chlorine retention was poor, agreeing with field observations. The FGD WW Se was retained in soil near the inlet end of the columns, indicating its limited mobility under reduced conditions. Sequential extraction procedure revealed that retained Se was mainly sequestered as stable/residual forms. Bulk- and micro-X-ray absorption near-edge structure spectroscopy confirmed that Se was mainly retained as reduced/stable species [Se(IV), organic Se, and Se(0)]. This study provides direct evidence for FGD WW Se retention in water-saturated soil via the transformation of oxidized Se into reduced/stable forms. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
A novel application of dielectric stack actuators: a pumping micromixer
NASA Astrophysics Data System (ADS)
Solano-Arana, Susana; Klug, Florian; Mößinger, Holger; Förster-Zügel, Florentine; Schlaak, Helmut F.
2018-07-01
The fabrication of pumping micromixers as a novel application of dielectric stack actuators is proposed in this work. DEA micromixers can be valuable for medical and pharmaceutical applications, due to: firstly, the biocompatibility of the used materials (PDMS and graphite); secondly, the pumping is done with peristaltic movements, allowing only the walls of the channel to be in contact with the liquid, avoiding possible contamination from external parts; and thirdly, the low flow velocity in the micromixers required in many applications. The micromixer based on peristasltic movements will not only mix, but also pump the fluids in and out the device. The developed device is a hybrid micromixer: active, because it needs a voltage source to enhance the quality and speed of the mixing; and passive, with a similar shape to the well-known Y-type micromixers. The proposed micromixer is based on twelve stack actuators distributed in: two pumping chambers, consisting of four stack actuators in series; and a mixing chamber, made of four consecutive stack actuators with 30 layers per stack. The DEA micromixer is able to mix two solutions with a flow rate of 21.5 μl min–1 at the outlet, applying 1500 V at 10 Hz and actuating two actuators at a time.
Optimization Design of Bipolar Plate Flow Field in PEM Stack
NASA Astrophysics Data System (ADS)
Wen, Ming; He, Kanghao; Li, Peilong; Yang, Lei; Deng, Li; Jiang, Fei; Yao, Yong
2017-12-01
A new design of bipolar plate flow field in proton exchange membrane (PEM) stack was presented to develop a high-performance transfer efficiency of the two-phase flow. Two different flow fields were studied by using numerical simulations and the performance of the flow fields was presented. the hydrodynamic properties include pressure gap between inlet and outlet, the Reynold’s number of the two types were compared based on the Navier-Stokes equations. Computer aided optimization software was implemented in the design of experiments of the preferable flow field. The design of experiments (DOE) for the favorable concept was carried out to study the hydrodynamic properties when changing the design parameters of the bipolar plate.
Porter, Chad K; Thura, Nadia; Schlett, Carey D; Sanders, John W; Tribble, David R; Monteville, Marshall R; Riddle, Mark S
2015-01-01
Knowledge of disease burden attributable to functional gastrointestinal disorders (FGD) in travelers is lacking, despite the high incidence of travelers' diarrhea (TD) associated with increased FGD risk. One tool for assessing the impact of disease on health-related quality of life is the health utility index (HUI), which values health states based on preferential health outcomes. Health utilities can be used as preference weights in the estimation of quality-adjusted life-years (QALYs). Six months following travel to Egypt or Turkey, 120 US military personnel completed a survey on TD during deployment, health-related quality of life (SF-36), and the onset of functional bowel disorders (Rome II). Elements from the SF-36 were used to develop SF-6D values, which were combined with health state valuations to enable calculation of HUI scores for each subject. Mean index scores were compared across functional outcomes, specific symptoms, and demographic profiles. The presence of FGD significantly reduced index scores, with irritable bowel syndrome (IBS) and dyspepsia showing the greatest impact (-0.17 and -0.19, respectively) compared with those with no FGD (p < 0.05). Importantly, however, several individuals met multiple FGD outcome definitions. Additionally, a number of symptoms associated with abnormal bowel habits and abdominal pain were associated with reduced index scores regardless of outcome. FGD are associated with significant morbidity as assessed by HUIs. Given the strong link between TD and FGD as well as the large number of travelers from the developed to the developing world, additional study is needed to further understand this association and efforts aimed at primary disease prevention are warranted. Published 2015. This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Development of a Cl-impregnated activated carbon for entrained-flow capture of elemental mercury.
Ghorishi, S Behrooz; Keeney, Robert M; Serre, Shannon D; Gullett, Brian K; Jozewicz, Wojciech S
2002-10-15
Efforts to discern the role of an activated carbon's surface functional groups on the adsorption of elemental mercury (Hg0) and mercuric chloride demonstrated that chlorine (Cl) impregnation of a virgin activated carbon using dilute solutions of hydrogen chloride leads to increases (by a factor of 2-3) in fixed-bed capture of these mercury species. A commercially available activated carbon (DARCO FGD, NORITAmericas Inc. [FGD])was Cl-impregnated (Cl-FGD) [5 lb (2.3 kg) per batch] and tested for entrained-flow, short-time-scale capture of Hg0. In an entrained flow reactor, the Cl-FGD was introduced in Hg0-laden flue gases (86 ppb of Hg0) of varied compositions with gas/solid contact times of about 3-4 s, resulting in significant Hg0 removal (80-90%), compared to virgin FGD (10-15%). These levels of Hg0 removal were observed across a wide range of very low carbon-to-mercury weight ratios (1000-5000). Variation of the natural gas combustion flue gas composition, by doping with nitrogen oxides and sulfur dioxide, and the flow reactor temperature (100-200 degrees C) had minimal effects on Hg0 removal bythe Cl-FGD in these carbon-to-mercury weight ratios. These results demonstrate significant enhancement of activated carbon reactivity with minimal treatment and are applicable to combustion facilities equipped with downstream particulate matter removal such as an electrostatic precipitator.
NASA Astrophysics Data System (ADS)
Swanger, K. M.; Schaefer, J. M.; Winckler, G.; Lamp, J. L.; Marchant, D. R.
2016-12-01
Based on surface exposure dating of moraines and drifts, East Antarctic outlet glaciers in the McMurdo Dry Valleys (MDV) advanced during the mid-Pliocene and/or early-Pleistocene. However, scatter in exposure ages is common for these deposits (and other glacial drifts throughout Antarctica), making it difficult to tie glacial advances to specific climate intervals. In order to constrain the sources of scatter, we mapped and dated 15 cold-based drifts in Taylor Valley and the Olympus Range in the MDV. A secondary goal was to build a regional climate record, for comparison with fluctuations of the local outlet glaciers. Our alpine drift record is confined to the late-Pleistocene, with glacial advances during interglacial periods. Based on 54 3He exposure dates on alpine drifts, age scatter is common in the MDV on both recent and ancient deposits. Where it occurs, age scatter is likely caused by inheritance of cosmogenic nuclides previous to glacial entrainment and stacking of multiple cold-based drifts. Nuclide inheritance of >1 Myr is possible, but this is relatively rare and confined to regions where englacial debris is sourced from stable, high-elevation plateaus. On the other hand, drifts associated with glaciers bound by steep cirque headwalls and arêtes exhibit significantly less age scatter. Given the cold-based nature of MDV alpine and outlet glaciers, deposition of multiple stacked drift sheets also contributes to age scatter, with the implication that it might be possible to date multiple advances of cold-based ice. These results serve to inform better sampling strategies on cold-based drifts throughout Antarctica.
Manifold regularized discriminative nonnegative matrix factorization with fast gradient descent.
Guan, Naiyang; Tao, Dacheng; Luo, Zhigang; Yuan, Bo
2011-07-01
Nonnegative matrix factorization (NMF) has become a popular data-representation method and has been widely used in image processing and pattern-recognition problems. This is because the learned bases can be interpreted as a natural parts-based representation of data and this interpretation is consistent with the psychological intuition of combining parts to form a whole. For practical classification tasks, however, NMF ignores both the local geometry of data and the discriminative information of different classes. In addition, existing research results show that the learned basis is unnecessarily parts-based because there is neither explicit nor implicit constraint to ensure the representation parts-based. In this paper, we introduce the manifold regularization and the margin maximization to NMF and obtain the manifold regularized discriminative NMF (MD-NMF) to overcome the aforementioned problems. The multiplicative update rule (MUR) can be applied to optimizing MD-NMF, but it converges slowly. In this paper, we propose a fast gradient descent (FGD) to optimize MD-NMF. FGD contains a Newton method that searches the optimal step length, and thus, FGD converges much faster than MUR. In addition, FGD includes MUR as a special case and can be applied to optimizing NMF and its variants. For a problem with 165 samples in R(1600), FGD converges in 28 s, while MUR requires 282 s. We also apply FGD in a variant of MD-NMF and experimental results confirm its efficiency. Experimental results on several face image datasets suggest the effectiveness of MD-NMF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, J.S., Westinghouse Hanford
1996-05-10
This report shows the methods used to test the stack gas outlet concentration and emission rate of Volatile Organic Compounds as Total Non-Methane Hydrocarbons in parts per million by volume,grams per dry standard cubic meter, and grams per minute from the PUREX ETF stream number G6 on the Hanford Site. Test results are shown in Appendix B.1.
Multi-clad black display panel
Veligdan, James T.; Biscardi, Cyrus; Brewster, Calvin
2002-01-01
A multi-clad black display panel, and a method of making a multi-clad black display panel, are disclosed, wherein a plurality of waveguides, each of which includes a light-transmissive core placed between an opposing pair of transparent cladding layers and a black layer disposed between transparent cladding layers, are stacked together and sawed at an angle to produce a wedge-shaped optical panel having an inlet face and an outlet face.
Co-flow anode/cathode supply heat exchanger for a solid-oxide fuel cell assembly
Haltiner, Jr., Karl J.; Kelly, Sean M.
2005-11-22
In a solid-oxide fuel cell assembly, a co-flow heat exchanger is provided in the flow paths of the reformate gas and the cathode air ahead of the fuel cell stack, the reformate gas being on one side of the exchanger and the cathode air being on the other. The reformate gas is at a substantially higher temperature than is desired in the stack, and the cathode gas is substantially cooler than desired. In the co-flow heat exchanger, the temperatures of the reformate and cathode streams converge to nearly the same temperature at the outlet of the exchanger. Preferably, the heat exchanger is formed within an integrated component manifold (ICM) for a solid-oxide fuel cell assembly.
Dou, Weixiao; Zhou, Zhen; Ye, Jiongjiong; Huang, Rongwei; Jiang, Lu-Man; Chen, Guofeng; Fei, Xiaoyun
2017-09-01
Flue gas desulfurization (FGD) wastewater treatment by conventional neutralization, chemical precipitation and coagulation process removes most suspended solids and heavy metals, and provides an effluent rich in calcium, alkalinity and chloride, which obstructs its reclamation and reuse but is in favor of phosphorus (P) precipitation. The goals of this study were to investigate feasibility of reusing FGD effluent as a calcium source for P removal from P-rich wastewater. Results revealed that increasing the volumetric ratio between FGD effluent and P-rich wastewater achieved higher pH value and Ca/P ratio, and thus enhanced P removal efficiency to 94.3% at the ratio of 40%. X-ray diffraction and scanning electron microscope analysis of harvested precipitates showed that increasing pH from 8 to 10 induced the conversion of hydroxyapatite to tri-calcium phosphate, and then to whitlockite. This study demonstrated that for reusing FGD effluent for P removal was highly feasible, both technically and economically. This process not only saves the cost of precipitants for P removal, but also provides an economical alternative for current zero liquid discharge technology for FGD wastewater, which requires high energy consumption and capital costs.
Coal Combustion Residual Beneficial Use Evaluation: Fly Ash Concrete and FGD Gypsum Wallboard
This page contains documents related to the evaluation of coal combustion residual beneficial use of fly ash concrete and FGD gypsum wallboard including the evaluation itself and the accompanying appendices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapoza, R.J.; Vollmer, H.R.; Haberly, K.L.
1992-11-01
Fiberglass reinforced plastic (FRP) materials offer excellent corrosion-resistant properties and long-term cost advantages compared to exotic alloys or organic lining systems. This guideline document provides potential buyers of FRP FGD (flue gas desulfurization) equipment with enough knowledge of FRP materials and methods to make informed decisions when procuring FRP equipment or services. It is divided into the following chapters: application criteria, procurement strategies, FRP basics, guidelines for designing FRP equipment, quality management. A glossary and manufacturers information/recommendations are included.
CONTROLLING SO2 EMISSIONS: A REVIEW OF TECHNOLOGIES
The report describes flue gas desulfurization (FGD) technologies, assesses their applications, and characterizes their performance. Additionally, it describes some of the advancements that have occurred in FGD technologies. Finally, it presents an analysis of the costs associated...
Identification of novel mutations in Mexican patients with Aarskog-Scott syndrome.
Pérez-Coria, Mariana; Lugo-Trampe, José J; Zamudio-Osuna, Michell; Rodríguez-Sánchez, Iram P; Lugo-Trampe, Angel; de la Fuente-Cortez, Beatriz; Campos-Acevedo, Luis D; Martínez-de-Villarreal, Laura E
2015-05-01
Aarskog-Scott syndrome (AAS), also known as faciogenital dysplasia (FGD, OMIM # 305400), is an X-linked disorder of recessive inheritance, characterized by short stature and facial, skeletal, and urogenital abnormalities. AAS is caused by mutations in the FGD1 gene (Xp11.22), with over 56 different mutations identified to date. We present the clinical and molecular analysis of four unrelated families of Mexican origin with an AAS phenotype, in whom FGD1 sequencing was performed. This analysis identified two stop mutations not previously reported in the literature: p.Gln664* and p.Glu380*. Phenotypically, every male patient met the clinical criteria of the syndrome, whereas discrepancies were found between phenotypes in female patients. Our results identify two novel mutations in FGD1, broadening the spectrum of reported mutations; and provide further delineation of the phenotypic variability previously described in AAS.
Identification of novel mutations in Mexican patients with Aarskog–Scott syndrome
Pérez-Coria, Mariana; Lugo-Trampe, José J; Zamudio-Osuna, Michell; Rodríguez-Sánchez, Iram P; Lugo-Trampe, Angel; de la Fuente-Cortez, Beatriz; Campos-Acevedo, Luis D; Martínez-de-Villarreal, Laura E
2015-01-01
Aarskog–Scott syndrome (AAS), also known as faciogenital dysplasia (FGD, OMIM # 305400), is an X-linked disorder of recessive inheritance, characterized by short stature and facial, skeletal, and urogenital abnormalities. AAS is caused by mutations in the FGD1 gene (Xp11.22), with over 56 different mutations identified to date. We present the clinical and molecular analysis of four unrelated families of Mexican origin with an AAS phenotype, in whom FGD1 sequencing was performed. This analysis identified two stop mutations not previously reported in the literature: p.Gln664* and p.Glu380*. Phenotypically, every male patient met the clinical criteria of the syndrome, whereas discrepancies were found between phenotypes in female patients. Our results identify two novel mutations in FGD1, broadening the spectrum of reported mutations; and provide further delineation of the phenotypic variability previously described in AAS. PMID:26029706
Environmental chamber measurements of mercury flux from coal utilization by-products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pekney, Natalie J.; Martello, Donald; Schroeder, Karl
2009-05-01
An environmental chamber was constructed to measure the mercury flux from coal utilization by-product (CUB) samples. Samples of fly ash, FGD gypsum, and wallboard made from FGD gypsum were tested under both dark and illuminated conditions with or without the addition of water to the sample. Mercury releases varied widely, with 7- day experiment averages ranging from -6.8 to 73 ng/m(2) h for the fly ash samples and -5.2 to 335 ng/m(2) h for the FGD/wallboard samples. Initial mercury content, fly ash type, and light exposure had no observable consistent effects on the mercury flux. For the fly ash samples,more » the effect of a mercury control technology was to decrease the emission. For three of the four pairs of FGD gypsum and wallboard samples, the wallboard sample released less (or absorbed more) mercury than the gypsum.« less
Environmental chamber measurements of mercury flux from coal utilization by-products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pekney, N.J.; Martello, D.V.; Schroeder, K.T.
2009-05-01
An environmental chamber was constructed to measure the mercury flux from coal utilization by-product (CUB) samples. Samples of fly ash, FGD gypsum, and wallboard made from FGD gypsum were tested under both dark and illuminated conditions with or without the addition of water to the sample. Mercury releases varied widely, with 7-day experiment averages ranging from -6.8 to 73 ng/m2 h for the fly ash samples and -5.2 to 335 ng/m2 h for the FGD/wallboard samples. Initial mercury content, fly ash type, and light exposure had no observable consistent effects on the mercury flux. For the fly ash samples, themore » effect of a mercury control technology was to decrease the emission. For three of the four pairs of FGD gypsum and wallboard samples, the wallboard sample released less (or absorbed more) mercury than the gypsum.« less
The effects of flue gas desulfurization (FGD) system additives on solid by-products. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huyck, K.A.; Tatum, G.S.; DeKraker, D.P.
This study was designed to examine characteristics of by-products from flue gas desulfurization (FGD) systems that use performance-enhancing additives. The by-products were evaluated for handling, disposal, properties, and utilization potential. This study was designed to identify potential operation-limiting consequences (fatal flaws) caused by using FGD system additives. It was not intended to be an all-encompassing study of the possible process, environmental, and utilization circumstances at each plant. Seven utilities conducting additive testing agreed to provide samples for this study both before and during their testing. Solid samples were collected from FGD systems using the following additives: di-basic acid (DBA), whichmore » is a mixture of succinic, glutaric, and adipic acids; formate; sulfur; ethylene diamine tetraacetic acid (EDTA); and chloride. Changes in handling properties that may alter process operations were observed at sites where DBS was used. Changes in leaching behavior, permeability and unconfined compressive strength (properties that affect by-product disposal properties) showed no clear trend for additive or system type. The intent of this study is to provide an overall assessment of potential system-limiting effects of FGD additive use. There were no overriding problems relating to disposal with the use of additives. However, properties of solids produced with and without additives should be tested at each site prior to use of an FGD system additive. This is necessary because of the variability in state disposal and permitting requirements and the influence of specific operating conditions on by-product properties.« less
Pressurized Testing of Solid Oxide Electrolysis Stacks with Advanced Electrode-Supported Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
J. E. O'Brien; X. Zhang; G. K. Housley
2012-06-01
A new facility has been developed at the Idaho National Laboratory for pressurized testing of solid oxide electrolysis stacks. Pressurized operation is envisioned for large-scale hydrogen production plants, yielding higher overall efficiencies when the hydrogen product is to be delivered at elevated pressure for tank storage or pipelines. Pressurized operation also supports higher mass flow rates of the process gases with smaller components. The test stand can accommodate cell dimensions up to 8.5 cm x 8.5 cm and stacks of up to 25 cells. The pressure boundary for these tests is a water-cooled spool-piece pressure vessel designed for operation upmore » to 5 MPa. The stack is internally manifolded and operates in cross-flow with an inverted-U flow pattern. Feed-throughs for gas inlets/outlets, power, and instrumentation are all located in the bottom flange. The entire spool piece, with the exception of the bottom flange, can be lifted to allow access to the internal furnace and test fixture. Lifting is accomplished with a motorized threaded drive mechanism attached to a rigid structural frame. Stack mechanical compression is accomplished using springs that are located inside of the pressure boundary, but outside of the hot zone. Initial stack heatup and performance characterization occurs at ambient pressure followed by lowering and sealing of the pressure vessel and subsequent pressurization. Pressure equalization between the anode and cathode sides of the cells and the stack surroundings is ensured by combining all of the process gases downstream of the stack. Steady pressure is maintained by means of a backpressure regulator and a digital pressure controller. A full description of the pressurized test apparatus is provided in this paper.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... produces both electric (or mechanical) and useful thermal energy from the same primary energy source. Coke.... Conventional technology means wet flue gas desulfurization (FGD) technology, dry FGD technology, atmospheric fluidized bed combustion technology, and oil hydrodesulfurization technology. Distillate oil means fuel oils...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isaacs, G.A.; Zada, F.K.
1975-09-01
Results are given of a survey of the flue gas desulfurization (FGD) systems at Kansas City Power and Light Co.'s Hawthorn Power Station. The FGD systems on Hawthorn boilers 3 and 4 were designed to operate by injection of dry limestone in the boiler's furnace, followed by tail gas scrubbing. Because of tube plugging in boiler 4 the mode of operation of the FGD system on that boiler was modified: ground limestone is now introduced into the flue gas near the gas inlet to the scrubber tower. (GRA)
FGD liner experiments with wetlands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitsch, W.J.; Ahn, C.; Wolfe, W.E.
1999-07-01
The construction of artificial wetlands for wastewater treatment often requires impermeable liners not only to protect groundwater resources but also to ensure that there is adequate water in the wetland to support appropriate aquatic life, particularly wetland vegetation. Liners or relatively impervious site soils are very important to the success of constructed treatment wetlands in areas where ground water levels are typically close to the ground surface. This study, carried out at the Olentangy River Wetland Research Park, investigated the use of FGD material from sulfur scrubbers as a possible liner material for constructed wetlands. While several studies have investigatedmore » the use of FGD material to line ponds, no studies have investigated the use of this material as a liner for constructed wetlands. They used experimental mesocosms to see the effect of FGD liner materials in constructed wetlands on water quality and on wetland plant growth. This paper presents the results of nutrient analyses and physicochemical investigation of leachate and surface outflow water samples collected from the mesocosms. Plant growth and biomass of wetland vegetation are also included in this paper. First two year results are reported by Ahn et al. (1998, 1999). The overall goal of this study is the identification of advantages and disadvantages of using FGD by-product as an artificial liner in constructed wetlands.« less
Liu, Ren-ping; Guo, Bin; Ren, Ailing; Bian, Jing-feng
2010-10-01
Some samples of semi-dry flue gas desulfurization (FGD) ash were taken from sinter gas of a steel factory. Scanning electron microscope (SEM) and X-ray diffraction (XRD) analyses were employed to identify the samples in order to investigate their physical and chemical characteristics. The results show that semi-dry FGD ash from a steel factory is stable under atmospheric conditions. It has irregular shape, a smooth surface and loose construction. The size of FGD ash particles is around 0.5-25 µm, the average size is about 5 µm and the median diameter is 4.18 µm. Semi-dry FGD ash from a steel factory consists of CaSO₃, CaSO₄, CaCO₃, some amorphous vitreous material and unburned carbon. An experimental method was found to study the oxidation characteristics of ash. A prediction model of the oxidation efficiency was obtained based on response surface methodology. The results show that not only the temperature, but also gas:solid ratio, play an important role in influencing the oxidation efficiency. The interactions of the gas:solid ratio with temperature play an essential role. An improved response surface model was obtained which can be helpful to describe the degree of oxidation efficiency of semi-dry FGD ash.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
A test program to collect and analyze size-fractionated stack gas particulate samples for selected inorganic hazardous air pollutants (HAPs) was conducted . Specific goals of the program are (1) the collection of one-gram quantities of size-fractionated stack gas particulate matter for bulk (total) and surface chemical characterization, and (2) the determination of the relationship between particle size, bulk and surface (leachable) composition, and unit load. The information obtained from this program identifies the effects of unit load, particle size, and wet FGD system operation on the relative toxicological effects of exposure to particulate emissions. Field testing was conducted in twomore » phases. The Phase I field program was performed over the period of August 24 through September 20, 1992, at the Tennessee Valley Authority Widows Creek Unit 8 Power Station, located near Stevenson (Jackson County), Alabama, on the Tennessee River. Sampling activities for Phase II were conducted from September 11 through October 14, 1993. Widows Creek Unit 8 is a 575-megawatt plant that uses bituminous coal averaging 3.7% sulfur and 13% ash. Downstream of the boiler, a venture wet scrubbing system is used for control of both sulfur dioxide and particulate emissions. There is no electrostatic precipitator (ESP) in this system. This system is atypical and represents only about 5% of the US utility industry. However, this site was chosen for this study because of the lack of information available for this particulate emission control system.« less
DEFINITIVE SOX CONTROL PROCESS EVALUATIONS: LIMESTONE, DOUBLE ALKALI, AND CITRATE FGD PROCESSES
The report gives results of a detailed comparative technical and economic evaluation of limestone slurry, generic double alkali, and citrate flue gas desulfurization (FGD) processes, assuming proven technology and using representative power plant, process design, and economic pre...
Adeli, Ardeshir; Read, John J; Brooks, John P; Miles, Dana; Feng, Gary; Jenkins, Johnie N
2017-03-01
The inability to incorporate broiler litter (BL) into permanent hayfields and pastures leads to nutrient accumulation near the soil surface and increases the potential transport of nutrients in runoff. This study was conducted on Marietta silt loam soil to determine the effect of flue gas desulfurization (FGD) gypsum and lignite on P, N, C, and microbial concentrations in runoff. Treatments were (i) control (unfertilized) and (ii) BL at 13.4 Mg ha alone or (iii) treated with either FGD gypsum or lignite applied at 20% (w/w) (2.68 Mg ha). Rainfall simulators were used to produce a 5.6 cm h storm event sufficient in duration to cause 15 min of continuous runoff. Repeated rains were applied at 3-d intervals to determine how long FGD gypsum and lignite are effective in reducing loss of litter-derived N, P, and C from soil. Application of BL increased N, P, and C concentrations in runoff as compared to the control. Addition of FGD gypsum reduced ( < 0.05) water-soluble P and dissolved organic C concentrations in runoff by 39 and 16%, respectively, as compared to BL alone. Lignite reduced runoff total N and NH-N concentrations by 38 and 70%, respectively, as compared to BL alone. Addition of FGD gypsum or lignite failed to significantly reduce microbial loads in runoff, although both treatments reduced microbial concentration by >20%. Thus, BL treated with FGD and lignite can be considered as cost-effective management practices in the mitigation of P, N, and C and possibly microbial concentration in runoff. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Chemical and physical properties of dry flue gas desulfurization products.
Kost, David A; Bigham, Jerry M; Stehouwer, Richard C; Beeghly, Joel H; Fowler, Randy; Traina, Samuel J; Wolfe, William E; Dick, Warren A
2005-01-01
Beneficial and environmentally safe recycling of flue gas desulfurization (FGD) products requires detailed knowledge of their chemical and physical properties. We analyzed 59 dry FGD samples collected from 13 locations representing four major FGD scrubbing technologies. The chemistry of all samples was dominated by Ca, S, Al, Fe, and Si and strong preferential partitioning into the acid insoluble residue (i.e., coal ash residue) was observed for Al, Ba, Be, Cr, Fe, Li, K, Pb, Si, and V. Sulfur, Ca, and Mg occurred primarily in water- or acid-soluble forms associated with the sorbents or scrubber reaction products. Deionized water leachates (American Society for Testing and Materials [ASTM] method) and dilute acetic acid leachates (toxicity characteristic leaching procedure [TCLP] method) had mean pH values of >11.2 and high mean concentrations of S primarily as SO(2-)4 and Ca. Concentrations of Ag, As, Ba, Cd, Cr, Hg, Pb, and Se (except for ASTM Se in two samples) were below drinking water standards in both ASTM and TCLP leachates. Total toxicity equivalents (TEQ) of dioxins, for two FGD products used for mine reclamation, were 0.48 and 0.53 ng kg(-1). This was similar to the background level of the mine spoil (0.57 ng kg(-1)). The FGD materials were mostly uniform in particle size. Specific surface area (m2 g(-1)) was related to particle size and varied from 1.3 for bed ash to 9.5 for spray dryer material. Many of the chemical and physical properties of these FGD samples were associated with the quality of the coal rather than the combustion and SO2 scrubbing processes used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Y.S.
Dry regenerative sorption processes have recently attracted increasing attention in flue gas desulfurization (FGD) because of their several advantages over the conventional wet-scrubbing processes. Dry sorbents are usually made by coating a transition or alkaline earth metal precursor on the surface of a porous support. Major disadvantages of these sorbents prepared by the conventional methods include relatively poor attrition resistance and low SO{sub 2} sorption capacity. The physical and especially chemical attrition (associated with the sulphation-oxidation-reduction cycles in the process) deteriorates the performance of the sorbents. The low SO{sub 2} sorption capacity is primarily due to the small surface areamore » of the support. Materials with a high surface area are not used as the supports for FGD sorbents because these materials usually are not thermally stable at high temperatures. In the past year, the research supported by Ohio Coal Development Office was focused on synthesis and properties of sol-gel derived alumina and zeolite sorbents with improved properties for FGD. The sol-gel derived alumina has large surface area, mesopore size and excellent mechanical strength. Some alumina-free zeolites not only posses the basic properties required as a sorbent for FGD (hydrophobicity, thermal and chemical stability, mechanical strength) but also have extremely large surface area and selective surface chemistry. The major objectives of this research program were to synthesize the sol-gel derived sorbents and to explore the use of the zeolites either directly as adsorbents or as sorbent support for FGD. The research was aimed at developing novel FGD sorbents possessing better sorption equilibrium and kinetic properties and improved physical and chemical attrition resistance.« less
THE ADVANTAGE OF ILLINOIS COAL FOR FGD REMOVAL OF MERCURY
The paper gives results of an investigation conducted to characterize and modify mercury (Hg) speciation in Illinois coal combustion flue gas so that a Hg control strategy can be implemented in conventional flue gas desulfurization (FGD) units. Hg, in trace concentration in coal,...
Code of Federal Regulations, 2011 CFR
2011-07-01
... oven gas, and coal-water mixtures, are also included in this definition for the purposes of this.... Conventional technology means wet flue gas desulfurization (FGD) technology, dry FGD technology, atmospheric... with an alkaline reagent and water, whether introduced separately or as a premixed slurry or solution...
Producing ammonium sulfate from flue gas desulfurization by-products
Chou, I.-Ming; Bruinius, J.A.; Benig, V.; Chou, S.-F.J.; Carty, R.H.
2005-01-01
Emission control technologies using flue gas desulfurization (FGD) have been widely adopted by utilities burning high-sulfur fuels. However, these technologies require additional equipment, greater operating expenses, and increased costs for landfill disposal of the solid by-products produced. The financial burdens would be reduced if successful high-volume commercial applications of the FGD solid by-products were developed. In this study, the technical feasibility of producing ammonium sulfate from FGD residues by allowing it to react with ammonium carbonate in an aqueous solution was preliminarily assessed. Reaction temperatures of 60, 70, and 80??C and residence times of 4 and 6 hours were tested to determine the optimal conversion condition and final product evaluations. High yields (up to 83%) of ammonium sulfate with up to 99% purity were achieved under relatively mild conditions. The optimal conversion condition was observed at 60??C and a 4-hour residence time. The results of this study indicate the technical feasibility of producing ammonium sulfate fertilizer from an FGD by-product. Copyright ?? Taylor & Francis Inc.
Testing of heat exchanger systems for reheating flue gases from wet scrubbing desulfurization plants
NASA Astrophysics Data System (ADS)
Than, K.
1982-09-01
Two heat exchanger systems: the cyclic process of GEA and, the plate heat exchanger of Kablitz/Thyssen, for reheating flue gases, which have been cooled to about 50 to 55 C due to wet scrubbing, to the required temperature at the outlet of the stack by extracting the sensible heat of the hot flue gases were tested. The problem of building materials and on keeping clean the heat exchanger surface are emphasized.
Planar optical waveguides for optical panel having gradient refractive index core
Veligdan, James T.
2001-01-01
An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.
Planar optical waveguides for optical panel having gradient refractive index core
Veligdan, James T.
2004-08-24
An optical panel is disclosed. A plurality of stacked planar optical waveguides are used to guide light from an inlet face to an outlet face of an optical panel. Each of the optical waveguides comprises a planar sheet of core material having a central plane. The core material has an index of refraction which decreases as the distance from the central plane increases. The decrease in the index of refraction occurs gradually and continuously.
Modular package for cooling a laser diode array
Mundinger, David C.; Benett, William J.; Beach, Raymond J.
1992-01-01
A laser diode array is disclosed that includes a plurality of planar packages and active cooling. The laser diode array may be operated in a long duty cycle, or in continuous operation. A laser diode bar and a microchannel heat sink are thermally coupled in a compact, thin planar package having the laser diode bar located proximate to one edge. In an array, a number of such thin planar packages are secured together in a stacked configuration, in close proximity so that the laser diodes are spaced closely. The cooling means includes a microchannel heat sink that is attached proximate to the laser bar so that it absorbs heat generated by laser operation. To provide the coolant to the microchannels, each thin planar package comprises a thin inlet manifold and a thin outlet manifold connected to an inlet corridor and an outlet corridor. The inlet corridor comprises a hole extending through each of the packages in the array, and the outlet corridor comprises a hole extending through each of the packages in the array. The inlet and outlet corridors are connected to a conventional coolant circulation system. The laser diode array with active cooling has application as an optical pump for high power solid state lasers. Further, it can be incorporated in equipment such as communications devices and active sensors, and in military and space applications, and it can be useful in applications having space constraints and energy limitations.
Investigation Of A Mercury Speciation Technique For Flue Gas Desulfurization Materials
Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to bene...
Sustainable uses of FGD gypsum in agricultural systems
USDA-ARS?s Scientific Manuscript database
Interest in using gypsum as a management tool to improve crop yields and soil/water quality has recently increased. Abundant supply and availability of flue gas desulfurization (FGD) gypsum, a by-product of scrubbing sulfur (S) from combustion gases at coal-fired power plants, in major agricultural...
Santhanam, C J; Lunt, R R; Johnson, S L; Cooper, C B; Thayer, P S; Jones, J W
1979-01-01
This paper focuses on the incremental impacts of coal ash and flue gas desulfurization (FGD) wastes associated with increased coal usage by utilities and industry under the National Energy Plan (NEP). In the paper, 1985 and 2000 are the assessment points using the baseline data taken from the Annual Environmental Analysis Report (AEAR, September 1977). In each EPA region, the potential mix of disposal options has been broadly estimated and impacts assessed therefrom. In addition, future use of advanced combustion techniques has been taken into account. The quantities of coal ash and FGD wastes depend on ash and sulfur content of the coal, emission regulations, the types of ash collection and FGD systems, and operating conditions of the systems and boiler. The disposal of these wastes is (or will be) subject to Federal and State regulations. The one key legal framework concerning environmental impact on land is the Resource Conservation and Recovery Act (RCRA). RCRA and related Federal and State laws provide a sufficient statutory basis for preventing significant adverse health and environmental impacts from coal ash and FGD waste disposal. However, much of the development and implementation of specific regulations lie ahead. FGD wastes and coal ash and FGD wastes are currently disposed of exclusively on land. The most common land disposal methods are inpoundments (ponds) and landfills, although some mine disposal is also practiced. The potential environmental impacts of this disposal are dependent on the characteristics of the disposal site, characteristics of the coal ash and FGD wastes, control method and the degree of control employed. In general, the major potential impacts are ground and surface water contamination and the "degradation" of large quantities of land. However, assuming land is available for disposal of these wastes, control technology exists for environmentally sound disposal. Because of existing increases in coal use, the possibility of significant environmental impacts, both regionally and nationally, exists regardless of whether the NEP scenario develops or not. Existing baseline data indicate that with sound control technology and successful development and implementation of existing regulatory framework, regional scale impacts are likely to be small; however, site-specific impacts could be significant and need to be evaluated on a case-by-case basis. Both Federal and privately-funded programs are developing additional data and information on disposal of FGD sludges and coal ash. Continuation of these programs will provide additional vital information in the future. However, further information in several areas if desirable: further data on levels of radionuclides and trace metals in these wastes: studies on biological impacts of trace metals; and completion of current and planned studies on disposal problems associated with advanced combustion techniques like fluid bed combustion. PMID:540614
DEMONSTRATION OF WELLMAN-LORD/ALLIED CHEMICAL FGD TECHNOLOGY: DEMONSTRATION TEST SECOND YEAR RESULTS
The report gives results of an evaluation of the performance (over a 2-year period) of a full-scale flue gas desulfurization (FGD) unit to demonstrate the Wellman-Lord/Allied Chemical process. The process is regenerable, employing sodium sulfite wet scrubbing, thermal regeneratio...
SURVEY OF FLUE GAS DESULFURIZATION SYSTEMS: ST. CLAIR STATION, DETROIT EDISON CO
The report gives results of a survey of the flue gas desulfurization (FGD) system retrofitted on Unit 6 of Detroit Edison Co.'s St. Clair Station. The experimental FGD system, which operated through a 2-month (October 1976-January 1977) demonstration program, utilized a limestone...
Hydrologic transport of fecal bacteria attenuated by flu gas desulfurized (FGD) gypsum
USDA-ARS?s Scientific Manuscript database
Background Flue gas desulfurized (FGD) gypsum is a byproduct of coal-fired power plants. As a soil amendment for crop production it has the potential of improving soil water infiltration, soil conservation, and decreasing nutrient losses from broiler litter applications. Because broiler litter is a ...
Use of Flue Gas Desulfurization (FGD) Gypsum as a Heavy Metal Stabilizer in Contaminated Soils
Flue Gas Desulfurization (FGD) gypsum is a synthetic by-product generated from the flue gas desulfurization process in coal power plants. It has several beneficial applications such as an ingredient in cement production, wallboard production and in agricultural practice as a soil...
ASSESSING AS, HG AND SE SPECIATION AND TRANSPORT IN FLUE GAS DESULPHURIZATION MATERIAL AND DRYWALL
The risk associated with the reuse of flue gas desulphurization (FGD) material in drywall manufacture is largely determined by the distribution or mineralogical fractionation of mercury(Hg), arsenic (As) and selenium (Se). During coal combustion, FGD material is enriched in volat...
Stackable multi-port gas nozzles
Poppe, Steve; Rozenzon, Yan; Ding, Peijun
2015-03-03
One embodiment provides a reactor for material deposition. The reactor includes a chamber and at least one gas nozzle. The chamber includes a pair of susceptors, each having a front side and a back side. The front side mounts a number of substrates. The susceptors are positioned vertically so that the front sides of the susceptors face each other, and the vertical edges of the susceptors are in contact with each other, thereby forming a substantially enclosed narrow channel between the substrates mounted on different susceptors. The gas nozzle includes a gas-inlet component situated in the center and a detachable gas-outlet component stacked around the gas-inlet component. The gas-inlet component includes at least one opening coupled to the chamber, and is configured to inject precursor gases into the chamber. The detachable gas-outlet component includes at least one opening coupled to the chamber, and is configured to output exhaust gases from the chamber.
Small-Scale Metal Tanks for High Pressure Storage of Fluids
NASA Technical Reports Server (NTRS)
London, Adam (Inventor)
2016-01-01
Small scale metal tanks for high-pressure storage of fluids having tank factors of more than 5000 meters and volumes of ten cubic inches or less featuring arrays of interconnected internal chambers having at least inner walls thinner than gage limitations allow. The chambers may be arranged as multiple internal independent vessels. Walls of chambers that are also portions of external tank walls may be arcuate on the internal and/or external surfaces, including domed. The tanks may be shaped adaptively and/or conformally to an application, including, for example, having one or more flat outer walls and/or having an annular shape. The tanks may have dual-purpose inlet/outlet conduits of may have separate inlet and outlet conduits. The tanks are made by fusion bonding etched metal foil layers patterned from slices of a CAD model of the tank. The fusion bonded foil stack may be further machined.
Animal waste and FGD gypsum effects on bermudagrass and soil leachate nutrient contents
USDA-ARS?s Scientific Manuscript database
In previous experiments on newly relcaimed coal mine soils in northeastern Mississippi, applying poultry litter at 22.4 Mg ha-1 yr-1 enhanced bermudagrass (Cynodon dactylon L.) biomass and selected soil quality parameters. Additionally, co-application of 11.2 Mg ha-1 FGD gypsum and litter reduced so...
FGD gypsum filters remove soluble phosphorus from agricultural drainage waters
USDA-ARS?s Scientific Manuscript database
Decades of chicken litter applications has led to phosphorus (P) levels up to ten times the agronomic optimum in soils of the Delmarva Peninsula. This legacy P is a major source of P entering drainage ditches that eventually empty into the Chesapeake Bay. A Flue Gas Desulfurization (FGD) gypsum ditc...
SURVEY OF FLUE GAS DESULFURIZATION SYSTEMS: WILL COUNTY STATION, COMMONWEALTH EDISON CO
The report gives results of a second survey of the flue gas desulfurization (FGD) system on Unit 1 of Commonwealth Edison Co.'s Will County Station. The FGD system, started up in February 1972, uses a limestone slurry in two parallel scrubbing trains. Each train includes a ventur...
Effects of gypsum on trace metals in soils and earthworms
USDA-ARS?s Scientific Manuscript database
Mined gypsum has been beneficially used for many years as an agricultural amendment. Currently a large amount of flue gas desulfurization (FGD) gypsum is produced by removal of SO2 from flue gas streams when fuels with high S content are burned. The FGD gypsum, similar to mined gypsum, can enhance c...
Framework of risk assessment in relation to FGD-gypsum use as agricultural amendment
USDA-ARS?s Scientific Manuscript database
Due to the concerns by EPA of air pollution from coal fired power plants, the industry are building and retrofitting existing facilities to remove more impurities from the environment. Industry has introduced removal of fly ash contaminates before SO2 removal, allowing generation of FGD-gypsum with...
Utilization of FGD gypsum in agriculture for environmental benefits
USDA-ARS?s Scientific Manuscript database
This paper will discuss the utilization of FGD gypsum in agriculture for environmental benefits. Gypsum (CaSO4 .2H2O) has been used as an agricultural soil amendment for over 250 years. It is a soluble source of calcium and sulfur for crops and has been shown to improve soil physical and chemical pr...
FGD gypsum application: Impacts on soil P from city parks in the Tampa area
USDA-ARS?s Scientific Manuscript database
Controlling excessive P loss from agricultural fields has become a major issue in recent years. However, managed city parks may also contribute to P loss. Thus, a study was conducted at three different city parks located in the Tampa Area to evaluate the use of FGD gypsum as an amendment to reduce w...
Soil test and bermudagrass forage yield responses to animal waste and FGD gypsum ammendments
USDA-ARS?s Scientific Manuscript database
Knowledge of soil and plant responses to animal or industrial byproducts is needed for effective use of these potential amendments on reclaimed mine soil. This study compared seven treatments of 11.2 Mg ha-1 flue gas desulfurized (FGD) gypsum (control), 896 kg ha-1 NPK fertilizer (13-13-13), 22.4 M...
NASA Astrophysics Data System (ADS)
Picot, D.; Metkemeijer, R.; Bezian, J. J.; Rouveyre, L.
In this paper, experimental water and thermal balances with three proton exchange membrane fuel cells (PEMFC) are proposed. On the test facility of Ecole des Mines de Paris, three De Nora SPA fuel cell stacks have been successfully studied: An 1 kW e prototype using Nafion® 117, a 5 and a 10 kW e module using Nafion® 115. The averaged water symmetry factor determines strategies to avoid drying membrane. So, we propose analytical solutions to find compromises between humidification and cooling conditions, which determines outlet temperatures of gases. For transport applications, the space occupied by the power module must be reduced. One of the main efforts consists in decreasing the operative pressure. Thus, if adequate cooling power is applied, we show experimentally and theoretically the possibility to use De Nora PEM fuel cells with low pressure, without specific external humidification.
Impact of FGD gypsum soil amendment applications on soil and environmental quality
USDA-ARS?s Scientific Manuscript database
This paper will discuss the utilization of FGD gypsum in agriculture for improving soil quality and other environmental benefits. Gypsum (CaSO4 .2H2O) has been used as an agricultural soil amendment for over 250 years. It is a soluble source of calcium and sulfur- for crops and has been shown to i...
Tanum, L; Malt, U F
2000-09-01
We investigated the relationship between personality traits and response to treatment with the tetracyclic antidepressant mianserin or placebo in patients with functional gastrointestinal disorder (FGD) without psychopathology. Forty-eight patients completed the Buss-Durkee Hostility Inventory, Neuroticism Extroversion Openness -Personality Inventory (NEO-PI), and Eysenck Personality Questionnaire (EPQ), neuroticism + lie subscales, before they were consecutively allocated to a 7-week double-blind treatment study with mianserin or placebo. Treatment response to pain and target symptoms were recorded daily with the Visual Analogue Scale and Clinical Global Improvement Scale at every visit. A low level of neuroticism and little concealed aggressiveness predicted treatment outcome with the antidepressant drug mianserin in non-psychiatric patients with FGD. Inversely, moderate to high neuroticism and marked concealed aggressiveness predicted poor response to treatment. These findings were most prominent in women. Personality traits were better predictors of treatment outcome than serotonergic sensitivity assessed with the fenfluramine test. Assessment of the personality traits negativism, irritability, aggression, and neuroticism may predict response to drug treatment of FGD even when serotonergic sensitivity is controlled for. If confirmed in future studies, the findings point towards a more differential psychopharmacologic treatment of FGD.
Power Plant Bromide Discharges and Downstream Drinking Water Systems in Pennsylvania.
Good, Kelly D; VanBriesen, Jeanne M
2017-10-17
Coal-fired power plants equipped with wet flue gas desulfurization (FGD) systems have been implicated in increasing bromide levels and subsequent increases in disinfection byproducts at downstream drinking water plants. Bromide was not included as a regulated constituent in the recent steam electric effluent limitations guidelines and standards (ELGs) since the U.S. EPA analysis suggested few drinking water facilities would be affected by bromide discharges from power plants. The present analysis uses a watershed approach to identify Pennsylvania drinking water intakes downstream of wet FGD discharges and to assess the potential for bromide discharge effects. Twenty-two (22) public drinking water systems serving 2.5 million people were identified as being downstream of at least one wet FGD discharge. During mean August conditions (generally low-flow, minimal dilution) in receiving rivers, the median predicted bromide concentrations contributed by wet FGD at Pennsylvania intake locations ranged from 5.2 to 62 μg/L for the Base scenario (including only natural bromide in coal) and from 16 to 190 μg/L for the Bromide Addition scenario (natural plus added bromide for mercury control); ranges depend on bromide loads and receiving stream dilution capacity.
Takasuga, Akiko; Sato, Kunio; Nakamura, Ryouichi; Saito, Yosuke; Sasaki, Shinji; Tsuji, Takehito; Suzuki, Akio; Kobayashi, Hiroshi; Matsuhashi, Tamako; Setoguchi, Koji; Okabe, Hiroshi; Ootsubo, Toshitake; Tabuchi, Ichiro; Fujita, Tatsuo; Watanabe, Naoto; Hirano, Takashi; Nishimura, Shota; Watanabe, Toshio; Hayakawa, Makio; Sugimoto, Yoshikazu; Kojima, Takatoshi
2015-01-01
Recessive skeletal dysplasia, characterized by joint- and/or hip bone-enlargement, was mapped within the critical region for a major quantitative trait locus (QTL) influencing carcass weight; previously named CW-3 in Japanese Black cattle. The risk allele was on the same chromosome as the Q allele that increases carcass weight. Phenotypic characterization revealed that the risk allele causes disproportional tall stature and bone size that increases carcass weight in heterozygous individuals but causes disproportionately narrow chest width in homozygotes. A non-synonymous variant of FGD3 was identified as a positional candidate quantitative trait nucleotide (QTN) and the corresponding mutant protein showed reduced activity as a guanine nucleotide exchange factor for Cdc42. FGD3 is expressed in the growth plate cartilage of femurs from bovine and mouse. Thus, loss of FDG3 activity may lead to subsequent loss of Cdc42 function. This would be consistent with the columnar disorganization of proliferating chondrocytes in chondrocyte-specific inactivated Cdc42 mutant mice. This is the first report showing association of FGD3 with skeletal dysplasia. PMID:26306008
Steenblock, Charlotte; Heckel, Tobias; Czupalla, Cornelia; Espírito Santo, Ana Isabel; Niehage, Christian; Sztacho, Martin; Hoflack, Bernard
2014-06-27
The initial step of bone digestion is the adhesion of osteoclasts onto bone surfaces and the assembly of podosomal belts that segregate the bone-facing ruffled membrane from other membrane domains. During bone digestion, membrane components of the ruffled border also need to be recycled after macropinocytosis of digested bone materials. How osteoclast polarity and membrane recycling are coordinated remains unknown. Here, we show that the Cdc42-guanine nucleotide exchange factor FGD6 coordinates these events through its Src-dependent interaction with different actin-based protein networks. At the plasma membrane, FGD6 couples cell adhesion and actin dynamics by regulating podosome formation through the assembly of complexes comprising the Cdc42-interactor IQGAP1, the Rho GTPase-activating protein ARHGAP10, and the integrin interactors Talin-1/2 or Filamin A. On endosomes and transcytotic vesicles, FGD6 regulates retromer-dependent membrane recycling through its interaction with the actin nucleation-promoting factor WASH. These results provide a mechanism by which a single Cdc42-exchange factor controlling different actin-based processes coordinates cell adhesion, cell polarity, and membrane recycling during bone degradation. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.
Apparatus for sampling and characterizing aerosols
Dunn, Patrick F.; Herceg, Joseph E.; Klocksieben, Robert H.
1986-01-01
Apparatus for sampling and characterizing aerosols having a wide particle size range at relatively low velocities may comprise a chamber having an inlet and an outlet, the chamber including: a plurality of vertically stacked, successive particle collection stages; each collection stage includes a separator plate and a channel guide mounted transverse to the separator plate, defining a labyrinthine flow path across the collection stage. An opening in each separator plate provides a path for the aerosols from one collection stage to the next. Mounted within each collection stage are one or more particle collection frames.
NASA Astrophysics Data System (ADS)
Sun, Ye; Li, Zhi; Wang, Jian; Zhang, Dan; Gao, Yang; Zhang, He
2018-02-01
According to the installed capacity, coal type and the kinds of environmental protection facilities of coal-fired power plants in Jilin Province in China, five typical coal-fired units were chosen. PM2.5 from final stack outlet of five typical units was gain by Dekati PM2.5(Finland). The characteristics of PM2.5 composition in flue gases discharged into the air from selected coal-fueled power plants are analyzed in this paper.
Shock, Scott S; Noggle, Jessica J; Bloom, Nicholas; Yost, Lisa J
2009-04-01
Synthetic gypsum produced by flue-gas desulfurization (FGD) in coal-fired power plants (FGD gypsum) is put to productive use in manufacturing wallboard. FGD gypsum wallboard is widely used, accounting for nearly 30% of wallboard sold in the United States. Mercury is captured in flue gas and thus is one of the trace metals present in FGD gypsum; raising questions about the potential for mercury exposure from wallboard. Mercury is also one of the trace metals present in "natural" mined gypsum used to make wall board. Data available in the literature were not adequate to assess whether mercury in wallboard from either FGD or natural gypsum could volatilize into indoor air. In this study, mercury volatilization was evaluated using small-scale (5 L) glass and Teflon flux chambers, with samples collected using both iodated carbon and gold-coated sand traps. Mercury flux measurements made using iodated carbon traps (n=6) were below the detection limit of 11.5 ng/m2-day for all natural and synthetic gypsum wallboard samples. Mercury flux measurements made using gold-coated sand traps (n=6) were 0.92 +/- 0.11 ng/m2-day for natural gypsum wallboard and 5.9 +/- 2.4 ng/m2-day for synthetic gypsum wallboard. Room air mercury concentrations between 0.028 and 0.28 ng/m3 and between 0.13 and 2.2 ng/m3 were estimated based on the flux-rate data for natural and synthetic gypsum wallboard samples, respectively, and were calculated assuming a 3 m x 4 m x 5 m room, and 10th and 90th percentile air exchange rates of 0.18/hour and 1.26/hour. The resulting concentration estimates are well below the U.S. Environmental Protection Agency (EPA) reference concentration for indoor air elemental mercury of 300 ng/m3 and the Agency for Toxic Substances and Disease Registry minimal risk level (MRL) of 200 ng/m3. Further, these estimates are below background mercury concentrations in indoor air and within or below the range of typical background mercury concentrations in outdoor air.
Applying ACF to Desulfurization Process from Flue Gas
NASA Astrophysics Data System (ADS)
Liu, Yi; Zhang, Zhigang; Tang, Qiang; Cao, Zidong
2004-08-01
Inasmuch as the status of environmental pollution caused by SO2 is more and more serious and the policy of environmental protection is executed more and more strictly, desulfurization from flue gas (FGD) is introduced to a wide-spread field of national economy. By a comparison with lime-limestone method, the application of adsorption method in FGD is more effective in desulfurization and more adapted to the situation of our country in respect of its more valuable byproduct. However, the technique of adsorption method is limited by the large amount of adsorbent used. In this paper, activated carbon fiber (ACF) is proposed as a new type of adsorbent to apply in FGD. A series of experiments have been made in order to compare the performances between ACF and granular activated carbon (GAC) which has been mostly used. Experiments show that under the same working conditions ACF's adsorption capacity is 16.6 times as high as that of GAC, mass loss rate is 1/12 of GAC's, desorption efficiency of ACF can reach 99.9%. The theory of micropore adsorption dynamics is adopted to analyze the characteristics of both adsorbents. It is indicated that adsorbability and perfectibility of desorption are tightly related to the distribution of pores and the surface micromechanism of adsorbent surface. The accessibility of pores for specified adsorptive and the effects of capillary condensation are crucial factors to influence the process of FGD. According to the research of different adsorbents, conclusion can be drawn that ACF is a kind of good material with a strong selectivity for SO2. Compared with the traditional methods of FGD, the use of ACF can greatly economize the consumption of adsorbent and obviously reduce the introduction of new adsorbent, and at the same time keep down the equipment investment and operating cost.
Chen, Liming; Stehouwer, Richard; Tong, Xiaogang; Kost, Dave; Bigham, Jerry M; Dick, Warren A
2015-09-01
Abandoned coal-mined lands are a worldwide concern due to their potential negative environmental impacts, including erosion and development of acid mine drainage. A field study investigated the use of a dry flue gas desulfurization product for reclamation of abandoned coal mined land in USA. Treatments included flue gas desulfurization product at a rate of 280 Mg ha(-1) (FGD), FGD at the same rate plus 112 Mg ha(-1) yard waste compost (FGD/C), and conventional reclamation that included 20 cm of re-soil material plus 157 Mg ha(-1) of agricultural limestone (SOIL). A grass-legume sward was planted after treatment applications. Chemical properties of surface runoff and tile water (collected from a depth of 1.2m below the ground surface) were measured over both short-term (1-4 yr) and long-term (14-20 yr) periods following reclamation. The pH of surface runoff water was increased from approximately 3, and then sustained at 7 or higher by all treatments for up to 20 yr, and the pH of tile flow water was also increased and sustained above 5 for 20 yr. Compared with SOIL, concentrations of Ca, S and B in surface runoff and tile flow water were generally increased by the treatments with FGD product in both short- and long-term measurements and concentrations of the trace elements were generally not statistically increased in surface runoff and tile flow water over the 20-yr period. However, concentrations of As, Ba, Cr and Hg were occasionally elevated. These results suggest the use of FGD product for remediating acidic surface coal mined sites can provide effective, long-term reclamation. Copyright © 2015. Published by Elsevier Ltd.
Niksa, Stephen; Fujiwara, Naoki
2005-07-01
This article introduces a predictive capability for Hg retention in any Ca-based wet flue gas desulfurization (FGD) scrubber, given mercury (Hg) speciation at the FGD inlet, the flue gas composition, and the sulphur dioxide (SO2) capture efficiency. A preliminary statistical analysis of data from 17 full-scale wet FGDs connects flue gas compositions, the extents of Hg oxidation at FGD inlets, and Hg retention efficiencies. These connections clearly signal that solution chemistry within the FGD determines Hg retention. A more thorough analysis based on thermochemical equilibrium yields highly accurate predictions for total Hg retention with no parameter adjustments. For the most reliable data, the predictions were within measurement uncertainties for both limestone and Mg/lime systems operating in both forced and natural oxidation mode. With the U.S. Environmental Protection Agency's (EPA) Information Collection Request (ICR) database, the quantitative performance was almost as good for the most modern FGDs, which probably conform to the very high SO2 absorption efficiencies assumed in the calculations. The large discrepancies for older FGDs are tentatively attributed to the unspecified SO2 capture efficiencies and operating temperatures and to the possible elimination of HCl in prescrubbers. The equilibrium calculations suggest that Hg retention is most sensitive to inlet HCl and O2 levels and the FGD temperature; weakly dependent on SO2 capture efficiency; and insensitive to HgCl2, NO, CA:S ratio, slurry dilution level in limestone FGDs, and MgSO3 levels in Mg/lime systems. Consequently, systems with prescrubbers to eliminate HCl probably retain less Hg than fully integrated FGDs. The analysis also predicts re-emission of Hg(O) but only for inlet O2 levels that are much lower than those in full-scale FGDs.
Wh-filler-gap dependency formation guides reflexive antecedent search
Frazier, Michael; Ackerman, Lauren; Baumann, Peter; Potter, David; Yoshida, Masaya
2015-01-01
Prior studies on online sentence processing have shown that the parser can resolve non-local dependencies rapidly and accurately. This study investigates the interaction between the processing of two such non-local dependencies: wh-filler-gap dependencies (WhFGD) and reflexive-antecedent dependencies. We show that reflexive-antecedent dependency resolution is sensitive to the presence of a WhFGD, and argue that the filler-gap dependency established by WhFGD resolution is selected online as the antecedent of a reflexive dependency. We investigate the processing of constructions like (1), where two NPs might be possible antecedents for the reflexive, namely which cowgirl and Mary. Even though Mary is linearly closer to the reflexive, the only grammatically licit antecedent for the reflexive is the more distant wh-NP, which cowgirl. (1). Which cowgirl did Mary expect to have injured herself due to negligence? Four eye-tracking text-reading experiments were conducted on examples like (1), differing in whether the embedded clause was non-finite (1 and 3) or finite (2 and 4), and in whether the tail of the wh-dependency intervened between the reflexive and its closest overt antecedent (1 and 2) or the wh-dependency was associated with a position earlier in the sentence (3 and 4). The results of Experiments 1 and 2 indicate the parser accesses the result of WhFGD formation during reflexive antecedent search. The resolution of a wh-dependency alters the representation that reflexive antecedent search operates over, allowing the grammatical but linearly distant antecedent to be accessed rapidly. In the absence of a long-distance WhFGD (Experiments 3 and 4), wh-NPs were not found to impact reading times of the reflexive, indicating that the parser's ability to select distant wh-NPs as reflexive antecedents crucially involves syntactic structure. PMID:26500579
Thioredoxin Reductase 2 (TXNRD2) mutation associated with familial glucocorticoid deficiency (FGD).
Prasad, Rathi; Chan, Li F; Hughes, Claire R; Kaski, Juan P; Kowalczyk, Julia C; Savage, Martin O; Peters, Catherine J; Nathwani, Nisha; Clark, Adrian J L; Storr, Helen L; Metherell, Louise A
2014-08-01
Classic ACTH resistance, due to disruption of ACTH signaling, accounts for the majority of cases of familial glucocorticoid deficiency (FGD). Recently FGD cases caused by mutations in the mitochondrial antioxidant, nicotinamide nucleotide transhydrogenase, have highlighted the importance of redox regulation in steroidogenesis. We hypothesized that other components of mitochondrial antioxidant systems would be good candidates in the etiology of FGD. Whole-exome sequencing was performed on three related patients, and segregation of putative causal variants confirmed by Sanger sequencing of all family members. A TXNRD2-knockdown H295R cell line was created to investigate redox homeostasis. The study was conducted on patients from three pediatric centers in the United Kingdom. Seven individuals from a consanguineous Kashmiri kindred, six of whom presented with FGD between 0.1 and 10.8 years, participated in the study. There were no interventions. Identification and functional interrogation of a novel homozygous mutation segregating with the disease trait were measured. A stop gain mutation, p.Y447X in TXNRD2, encoding the mitochondrial selenoprotein thioredoxin reductase 2 (TXNRD2) was identified and segregated with disease in this extended kindred. RT-PCR and Western blotting revealed complete absence of TXNRD2 in patients homozygous for the mutation. TXNRD2 deficiency leads to impaired redox homeostasis in a human adrenocortical cell line. In contrast to the Txnrd2-knockout mouse model, in which embryonic lethality as a consequence of hematopoietic and cardiac defects is described, absence of TXNRD2 in humans leads to glucocorticoid deficiency. This is the first report of a homozygous mutation in any component of the thioredoxin antioxidant system leading to inherited disease in humans.
Desulfurization: Critical step towards enhanced selenium removal from industrial effluents.
Staicu, Lucian C; Morin-Crini, Nadia; Crini, Grégorio
2017-04-01
Selenium (Se) removal from synthetic solutions and from real Flue Gas Desulfurization (FGD) wastewater generated by a coal-fired power plant was studied for the first time using a commercial iron oxide impregnated strong base anion exchange resin, Purolite ® FerrIX A33E. In synthetic solutions, the resin showed high affinity for selenate and selenite, while sulfate exhibited a strong competition for both oxyanions. The FGD wastewater investigated is a complex system that contains Se (∼1200 μg L -1 ), SO 4 2- (∼1.1 g L -1 ), Cl - (∼9.5 g L -1 ), and Ca 2+ (∼5 g L -1 ), alongside a broad spectrum of toxic trace metals including Cd, Cr, Hg, Ni, and Zn. The resin performed poorly against Se in the raw FGD wastewater and showed moderate to good removal of several trace elements such as Cd, Cr, Hg, and Zn. In FGD effluent, sulfate was identified as a powerful competing anion for Se, having high affinity for the exchange active sites of the resin. The desulfurization of the FGD effluent using BaCl 2 led to the increase in Se removal from 3% (non-desulfurized effluent) to 80% (desulfurized effluent) by combined precipitation and ion exchange treatment. However, complete desulfurization using equimolar BaCl 2 could not be achieved due to the presence of bicarbonate that acts as a sulfate competitor for barium. In addition to selenium and sulfate removal, several toxic metals were efficiently removed (Cd: 91%; Cr: 100%; Zn: 99%) by the combined (desulfurization and ion exchange) treatment. Copyright © 2016 Elsevier Ltd. All rights reserved.
High Temperature Electrolysis Pressurized Experiment Design, Operation, and Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
J.E. O'Brien; X. Zhang; G.K. Housley
2012-09-01
A new facility has been developed at the Idaho National Laboratory for pressurized testing of solid oxide electrolysis stacks. Pressurized operation is envisioned for large-scale hydrogen production plants, yielding higher overall efficiencies when the hydrogen product is to be delivered at elevated pressure for tank storage or pipelines. Pressurized operation also supports higher mass flow rates of the process gases with smaller components. The test stand can accommodate planar cells with dimensions up to 8.5 cm x 8.5 cm and stacks of up to 25 cells. It is also suitable for testing other cell and stack geometries including tubular cells.more » The pressure boundary for these tests is a water-cooled spool-piece pressure vessel designed for operation up to 5 MPa. Pressurized operation of a ten-cell internally manifolded solid oxide electrolysis stack has been successfully demonstrated up 1.5 MPa. The stack is internally manifolded and operates in cross-flow with an inverted-U flow pattern. Feed-throughs for gas inlets/outlets, power, and instrumentation are all located in the bottom flange. The entire spool piece, with the exception of the bottom flange, can be lifted to allow access to the internal furnace and test fixture. Lifting is accomplished with a motorized threaded drive mechanism attached to a rigid structural frame. Stack mechanical compression is accomplished using springs that are located inside of the pressure boundary, but outside of the hot zone. Initial stack heatup and performance characterization occurs at ambient pressure followed by lowering and sealing of the pressure vessel and subsequent pressurization. Pressure equalization between the anode and cathode sides of the cells and the stack surroundings is ensured by combining all of the process gases downstream of the stack. Steady pressure is maintained by means of a backpressure regulator and a digital pressure controller. A full description of the pressurized test apparatus is provided in this report. Results of initial testing showed the expected increase in open-cell voltage associated with elevated pressure. However, stack performance in terms of area-specific resistance was enhanced at elevated pressure due to better gas diffusion through the porous electrodes of the cells. Some issues such as cracked cells and seals were encountered during testing. Full resolution of these issues will require additional testing to identify the optimum test configurations and protocols.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jarvis, J.B.; Terry, J.C.; Schubert, S.A.
The report gives results of the measurement of the adipic acid degradation rate in a bench-scale flue gas desulfurization (FGD) system, designed to simulate many of the important aspects of full-scale FGD systems. Results show that the adipic acid degradation rate depends on the sulfite oxidation rate, the adipic acid concentration, the presence of manganese in solution, and temperature. The degradation rate is also affected by pH, but only when manganese is present. Adipic acid degradation products identified in the liquid phase include valeric, butyric, propionic, succinic, and glutaric acids. When manganese was present, the predominant degradation products were succinicmore » and glutaric acids. Analysis of solids from the bench scale tests shows large concentrations of coprecipitated adipic acid in low oxidation sulfite solids. By contrast, low quantities of coprecipitated adipic acid were found in high oxidation gypsum solids.« less
Use of flue gas desulfurization gypsum for leaching Cd and Pb in reclaimed tidal flat soil.
Yang, Ping; Li, Xian; Tong, Ze-Jun; Li, Qu-Sheng; He, Bao-Yan; Wang, Li-Li; Guo, Shi-Hong; Xu, Zhi-Min
2016-04-01
A soil column leaching experiment was conducted to eliminate heavy metals from reclaimed tidal flat soil. Flue gas desulfurization (FGD) gypsum was used for leaching. The highest removal rates of Cd and Pb in the upper soil layers (0-30 cm) were 52.7 and 30.5 %, respectively. Most of the exchangeable and carbonate-bound Cd and Pb were removed. The optimum FGD gypsum application rate was 7.05 kg·m(-2), and the optimum leaching water amount for the application was 217.74 L·m(-2). The application of FGD gypsum (two times) and the extension of the leaching interval time to 20 days increased the heavy metal removal rate in the upper soil layers. The heavy metals desorbed from the upper soil layers were re-adsorbed and fixed in the 30-70 cm soil layers.
Sekoni, A O; Balogun, M R; Odukoya, O O; Inem, V; Onigbogi, O O
2014-03-01
This study was carried out to assess the blood donation practices and willingness to donate among residents of an urban slum. Cross sectional descriptive study design with a qualitative and quantitative component. Multistage sampling was used to select 400 respondents for the questionnaire interview while three FGD sessions were conducted guide among three groups of participants namely youths, men and women. The information collected was analyzed manually (FGD) and with Epi info version 3.5.3. Majority of the questionnaire respondents were female, married, traders, had at least secondary school education, with mean age of 37.6 years. Only 12.0% had donated in the past, the main reason given by non donors was that they had never been asked to donate; this was also a key finding in the FGD. Willingness to donate was positively associated with being a male, single and Christian, age was a significant predictor of previous donation while more of the previous donors were still willing to donate, more for family/friends (p=0.036) than voluntarily (p=0.001) this view was supported by the participants at the FGD. Members of this urban slum had poor practice of blood donation,had positive attitude and were willing to donate, there is need to mobilise and organise outreach blood donation programs to convert attitude into actual practice.
The near-source impacts of diesel backup generators in urban environments
NASA Astrophysics Data System (ADS)
Tong, Zheming; Zhang, K. Max
2015-05-01
Distributed power generation, located close to consumers, plays an important role in the current and future power systems. However, its near-source impacts in complex urban environments are not well understood. In this paper, we focused on diesel backup generators that participate in demand response (DR) programs. We first improved the micro-environmental air quality simulations by employing a meteorology processor, AERMET, to generate site-specific boundary layer parameters for the Large Eddy Simulation (LES) modeling. The modeling structure was then incorporated into the CTAG model to evaluate the environmental impacts of diesel backup generators in near-source microenvironments. We found that the presence of either tall upwind or downwind building can deteriorate the air quality in the near-stack street canyons, largely due to the recirculation zones generated by the tall buildings, reducing the near-stack dispersion. Decreasing exhaust momentum ratio (stack exit velocity/ambient wind velocity) draws more exhaust into the recirculation zone, and reduces the effective stack height, which results in elevated near-ground concentrations inside downwind street canyons. The near-ground PM2.5 concentration for the worst scenarios could well exceed 100 μg m-3, posing potential health risk to people living and working nearby. In general, older diesel backup generators (i.e., Tier 1, 2 or older) without the up-to-date emission control may significantly increase the pollutant concentration in the near-source street canyons if participating in DR programs. Even generators that comply with Tier-4 standards could lead to PM hotspots if their stacks are next to tall buildings. Our study implies that the siting of diesel backup generators stacks should consider not only the interactions of fresh air intake and exhaust outlet for the building housing the backup generators, but also the dispersion of exhaust plumes in the surrounding environment.
Limited-memory fast gradient descent method for graph regularized nonnegative matrix factorization.
Guan, Naiyang; Wei, Lei; Luo, Zhigang; Tao, Dacheng
2013-01-01
Graph regularized nonnegative matrix factorization (GNMF) decomposes a nonnegative data matrix X[Symbol:see text]R(m x n) to the product of two lower-rank nonnegative factor matrices, i.e.,W[Symbol:see text]R(m x r) and H[Symbol:see text]R(r x n) (r < min {m,n}) and aims to preserve the local geometric structure of the dataset by minimizing squared Euclidean distance or Kullback-Leibler (KL) divergence between X and WH. The multiplicative update rule (MUR) is usually applied to optimize GNMF, but it suffers from the drawback of slow-convergence because it intrinsically advances one step along the rescaled negative gradient direction with a non-optimal step size. Recently, a multiple step-sizes fast gradient descent (MFGD) method has been proposed for optimizing NMF which accelerates MUR by searching the optimal step-size along the rescaled negative gradient direction with Newton's method. However, the computational cost of MFGD is high because 1) the high-dimensional Hessian matrix is dense and costs too much memory; and 2) the Hessian inverse operator and its multiplication with gradient cost too much time. To overcome these deficiencies of MFGD, we propose an efficient limited-memory FGD (L-FGD) method for optimizing GNMF. In particular, we apply the limited-memory BFGS (L-BFGS) method to directly approximate the multiplication of the inverse Hessian and the gradient for searching the optimal step size in MFGD. The preliminary results on real-world datasets show that L-FGD is more efficient than both MFGD and MUR. To evaluate the effectiveness of L-FGD, we validate its clustering performance for optimizing KL-divergence based GNMF on two popular face image datasets including ORL and PIE and two text corpora including Reuters and TDT2. The experimental results confirm the effectiveness of L-FGD by comparing it with the representative GNMF solvers.
'Bugs' used to treat FGD wastewater
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blankinship, S.
2009-09-15
Tough regulation of heavy metals may justify a bioreactor approach in addition to chemical treatment of FGD wastewater. Two of Duke Energy' coal-fired plants, Belews Creek and Allen (in North Carolina) have installed new biological reactor systems to increase selenium removal to levels not achievable by existing scrubber waste water systems. The ABMet system removes nitrate and selenium in a single step. Progress Energy has installed the system at Roxboro and Mayo Stations, also in North Carolina. 1 fig., 2 photos.
Life Sciences Laboratory 2 Fan Exhaust Mixing Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flaherty, Julia E.; Antonio, Ernest J.
An SF 6 tracer release was performed in the LSL-II ventilation stack over the weekend of March 5, 2016. The primary purpose of this study was to experimentally determine the gaseous concentration of material from a fume hood to the fan outlet, as well as at typical worker locations, to gain an understanding of potential worker exposures impacts. Five different fan operating configurations were utilized to ensure that the full spectrum of historical operating configurations was addressed. Some summary points from this study include: •Relatively high concentrations were observed within the stack area. –Between 50 and 100% of the exhaustmore » concentration may be observed within the stack. •Background concentrations were observed outside the stack area. –Workers outside the stack itself, but on the roof, are unlikely to be impacted by the exhaust. •Elevated concentrations on the order of 25% of the exhaust concentrations were observed within the Penthouse. •Transport time from a laboratory fume hood to the exhaust fan is within one to two minutes. •Penthouse concentrations climb from background levels to steady state over 15+ minutes. •Wind speed and wind direction did not play a significant role in the test outcomes. –A slight bias in the concentration distribution may be discernable based on wind speed and direction. •When both fans are operating, material from fume hoods on the east side preferentially flow through the east fan, while material from fume hoods on the west side preferentially flow through the west fan. This effectively doubles the concentration at that fan. This mixing study will inform other study components to develop a more complete picture of the worker potential exposure from LSL-II Rooftop activities. Estimating the mean concentration in the stack from chemical inventories and fume hood emissions for both current and historical laboratory activities is a separate effort. These estimates of mean ventilation concentrations will utilize this mixing study to estimate the potential exposure to workers working in and around the LSL-II stack.« less
High precision innovative micropump for artificial pancreas
NASA Astrophysics Data System (ADS)
Chappel, E.; Mefti, S.; Lettieri, G.-L.; Proennecke, S.; Conan, C.
2014-03-01
The concept of artificial pancreas, which comprises an insulin pump, a continuous glucose meter and a control algorithm, is a major step forward in managing patient with type 1 diabetes mellitus. The stability of the control algorithm is based on short-term precision micropump to deliver rapid-acting insulin and to specific integrated sensors able to monitor any failure leading to a loss of accuracy. Debiotech's MEMS micropump, based on the membrane pump principle, is made of a stack of 3 silicon wafers. The pumping chamber comprises a pillar check-valve at the inlet, a pumping membrane which is actuated against stop limiters by a piezo cantilever, an anti-free-flow outlet valve and a pressure sensor. The micropump inlet is tightly connected to the insulin reservoir while the outlet is in direct communication with the patient skin via a cannula. To meet the requirement of a pump dedicated to closed-loop application for diabetes care, in addition to the well-controlled displacement of the pumping membrane, the high precision of the micropump is based on specific actuation profiles that balance effect of pump elasticity in low-consumption push-pull mode.
A rare genetic disorder causing persistent severe neonatal hypoglycaemia the diagnostic workup.
Francescato, Gaia; Salvatoni, Alessandro; Persani, Luca; Agosti, Massimo
2012-07-19
We report a case of familial glucocorticoid deficiency (FGD), a rare genetic autosomal-recessive disorder with typical hyperpigmentation of the skin and mucous membranes, severe hypoglycaemia, occasionally leading to seizures and coma, feeding difficulties, failure to thrive and infections. A newborn child was admitted, on his second day of life, to our neonatal intensive care unit because of seizures and respiratory insufficiency. Hyperpigmentation was not evident due to his Senegalese origin. The clinical presentation led us to consider a wide range of diagnostic hypothesis. Laboratory findings brought us to the diagnosis of FGD that was confirmed by molecular analysis showing an MC2R:p.Y254C mutation previously reported as causative of type 1 FGD and two novel heterozygous non-synonymous single-nucleotide polymorphisms in exon 2 and 3 of melanocortin 2 receptor accessory protein-α, whose role in the disease is currently unknown. The importance of an early collection and storage of blood samples during hypoglycaemic event is emphasised.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laseke, B.A. Jr.
The report presents the results of a survey of operational flue gas desulfurization (FGD) systems on coal-fired utility boilers in the United States. The FGD system installed on Unit 1 at the Duck Creek Station of Central Illinois Light Company is described in terms of design and performance. The system consists of four parallel, wet-limestone, rod-deck scrubber modules designed for 25% capacity each, providing a total sulfur dioxide removal efficiency of 85%. The bottom ash, fly ash, and scrubbing wastes are disposed of in a sludge pond lined with a natural impermeable material. The first module of this four modulemore » FGD system was placed in service on July 1, 1976, and operated intermittently throughout the remainder of the year and for approximately one month in early 1977. On July 23, 1978, the three remaining modules were completed and all four modules were placed in the gas path for treatment of high sulfur flue gas.« less
Xia, Min; Ye, Chunsong; Pi, Kewu; Liu, Defu; Gerson, Andrea R
2017-11-01
Selective removal of Ca and recovery of Mg by precipitation from flue gas desulfurization (FGD) wastewater has been investigated. Thermodynamic analysis of four possible additives, Na 2 CO 3 , Na 2 C 2 O 4 , NaF and Na 2 SO 4 , indicated that both carbonate and oxalate could potentially provide effective separation of Ca via precipitation from Mg in FGD wastewater. However, it was found experimentally that the carbonate system was not as effective as oxalate in this regard. The oxalate system performed considerably better, with Ca removal efficiency of 96% being obtained, with little Mg inclusion at pH 6.0 when the dosage was ×1.4 the stoichiometric requirement. On this basis, the subsequent recovery process for Mg was carried out using NaOH with two-step precipitation. The product was confirmed to be Mg(OH) 2 (using X-ray diffraction and thermo gravimetric analysis) with elemental analysis suggesting a purity of 99.3 wt.%.
Watanabe, Yoichi; Warmington, Leighton; Gopishankar, N
2017-01-01
Accurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the material property in response to radiation. These are available in the gel form as polymer gel dosimeter (PGD) and ferrous gel dosimeter (FGD) and in the solid form as solid plastic dosimeter (SPD). Those are made of a continuous uniform medium which polymerizes upon irradiation. Hence, the intrinsic spatial resolution of those dosimeters is very high, and it is only limited by the method by which one converts the dose information recorded by the medium to the absorbed dose. The current standard methods of the dose quantification are magnetic resonance imaging, optical computed tomography, and X-ray computed tomography. In particular, magnetic resonance imaging is well established as a method for obtaining clinically relevant dosimetric data by PGD and FGD. Despite the likely possibility of doing 3D dosimetry by PGD, FGD or SPD, the tools are still lacking wider usages for clinical applications. In this review article, we summarize the current status of PGD, FGD, and SPD and discuss the issue faced by these for wider acceptance in radiation oncology clinic and propose some directions for future development. PMID:28396725
Brynsvold, Glen V.; Lopez, John T.; Olich, Eugene E.; West, Calvin W.
1989-01-01
An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates.
Brynsvold, G.V.; Lopez, J.T.; Olich, E.E.; West, C.W.
1989-11-21
An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates. 14 figs.
Selenium Speciation and Management in Wet FGD Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Searcy, K; Richardson, M; Blythe, G
2012-02-29
This report discusses results from bench- and pilot-scale simulation tests conducted to determine the factors that impact selenium speciation and phase partitioning in wet FGD systems. The selenium chemistry in wet FGD systems is highly complex and not completely understood, thus extrapolation and scale-up of these results may be uncertain. Control of operating parameters and application of scrubber additives have successfully demonstrated the avoidance or decrease of selenite oxidation at the bench and pilot scale. Ongoing efforts to improve sample handling methods for selenium speciation measurements are also discussed. Bench-scale scrubber tests explored the impacts of oxidation air rate, tracemore » metals, scrubber additives, and natural limestone on selenium speciation in synthetic and field-generated full-scale FGD liquors. The presence and concentration of redox-active chemical species as well as the oxidation air rate contribute to the oxidation-reduction potential (ORP) conditions in FGD scrubbers. Selenite oxidation to the undesirable selenate form increases with increasing ORP conditions, and decreases with decreasing ORP conditions. Solid-phase manganese [Mn(IV)] appeared to be the significant metal impacting the oxidation of selenite to selenate. Scrubber additives were tested for their ability to inhibit selenite oxidation. Although dibasic acid and other scrubber additives showed promise in early clear liquor (sodium based and without calcium solids) bench-scale tests, these additives did not show strong inhibition of selenite oxidation in tests with higher manganese concentrations and with slurries from full-scale wet FGD systems. In bench-tests with field liquors, addition of ferric chloride at a 250:1 iron-to-selenium mass ratio sorbed all incoming selenite to the solid phase, although addition of ferric salts had no impact on native selenate that already existed in the field slurry liquor sample. As ORP increases, selenite may oxidize to selenate more rapidly than it sorbs to ferric solids. Though it was not possible to demonstrate a decrease in selenium concentrations to levels below the project'ale testing were evident at the pilot scale. Specifically, reducing oxidation air rate and ORP tends to either retain selenium as selenite in the liquor or shift selenium phase partitioning to the solid phase. Oxidation air flow rate control may be one option for managing selenium behavior in FGD scrubbers. Units that cycle load widely may find it more difficult to impact ORP conditions with oxidation air flow rate control alone. Because decreasing oxidation air rates to the reaction tank showed that all new selenium reported to the solids, the addition of ferric chloride to the pilot scrubber could not show further improvements in selenium behavior. Ferric chloride addition did shift mercury to the slurry solids, specifically to the fine particles. Several competing pathways may govern the reporting of selenium to the slurry solids: co-precipitation with gypsum into the bulk solids and sorption or co-precipitation with iron into the fine particles. Simultaneous measurement of selenium and mercury behavior suggests a holistic management strategy is best to optimize the fate of both of these elements in FGD waters. Work conducted under this project evaluated sample handling and analytical methods for selenium speciation in FGD waters. Three analytical techniques and several preservation methods were employed. Measurements of selenium speciation over time indicated that for accurate selenium speciation, it is best to conduct measurements on unpreserved, filtered samples as soon after sampling as possible. The capital and operating costs for two selenium management strategies were considered: ferric chloride addition and oxidation air flow rate control. For ferric chloride addition, as might be expected the reagent makeup costs dominate the overall costs, and range from 0.22 to 0.29 mills/kWh. For oxidation air flow rate control, a cursory comparison of capital costs and turndown capabilities for multi-stage and single-stage centrifugal blowers and several flow control methods was completed. For greenfield systems, changing the selection of blower type and flow control method may have payback periods of 4 to 5 years or more if based on energy savings alone. However, the benefits to managing redox chemistry in the scrubber could far outweigh the savings in electricity costs under some circumstances.« less
How does feedback in mini-CEX affect students' learning response?
Sudarso, Sulistiawati; Rahayu, Gandes Retno; Suhoyo, Yoyo
2016-12-19
This study was aimed to explore students' learning response toward feedback during mini-CEX encounter. This study used a phenomenological approach to identify the students' experiences toward feedback during mini-CEX encounter. Data was collected using Focus Group Discussion (FGD) for all students who were in their final week of clerkship in the internal medicine rotation. There were 4 FGD groups (6 students for each group). All FGD were audio-taped and transcribed verbatim. The FGD transcripts were analyzed thematically and managed using Atlas-ti (version 7.0). Feedback content and the way of providing feedback on mini-CEX stimulated students' internal process, including self-reflection, emotional response, and motivation. These internal processes encouraged the students to take action or do a follow-up on the feedback to improve their learning process. In addition, there was also an external factor, namely consequences, which also influenced the students' reaction to the follow-up on feedback. In the end, this action caused several learning effects that resulted in the students' increased self-efficacy, attitude, knowledge and clinical skill. Feedback content and the way of providing feedback on mini-CEX stimulates the students' internal processes to do a follow-up on feedback. However, another external factor also affects the students' decision on the follow-up actions. The follow-ups result in various learning effects on the students. Feedback given along with summative assessment enhances learning effects on students, as well. It is suggested that supervisors of clinical education are prepared to comprehend every factor influencing feedback on mini CEX to improve the students' learning response.
Identification of Risk Factors Associated with Transmission of Plague Disease in Eastern Zambia.
Nyirenda, Stanley S; Hang'ombe, Bernard M; Machang'u, Robert; Mwanza, Jackson; Kilonzo, Bukheti S
2017-09-01
Plague is a fatal, primarily rodent-flea-borne zoonotic disease caused by Yersinia pestis . The identification of risk factors of plague was investigated through questionnaire interview and conducting focus group discussion (FGD) in Sinda and Nyimba districts of eastern Zambia. A total of 104 questionnaires were administered to individual respondents and 20 groups consisting of 181 discussants, which comprised FGD team in this study. The study revealed that trapping, transportation, and preparation of rodents for food exposed the community to rodent and their fleas suggesting that plague may have occurred primarily by either flea bites or contact with infected wild rodents. The study also revealed that most people in communities consumed rodents as part of their regular diet; therefore, contact with small wild mammals was a common practice. The mode of transportation of freshly trapped rodents, in particular, carcasses risked human to flea bites. Questionnaire respondents (75%) and FGD discussants (55%) indicated that trappers preferred to carry rodent carcasses in small bags, whereas 55.8% and 20% respectively, reported hunters carrying carcasses in their pockets. Carrying of carcass skewers on trappers' shoulders was reported by 38.4% and 20% of individual respondents and FGD, respectively. All these activities were exposing humans to rodents and their fleas, the natural reservoirs and vectors of plague, respectively. This study also showed that there is a statistically significant (χ 2 = 4.6878, P < 0.05), between digging of rodents from their burrows and the presence of fleas on the hunter's bodies or clothes, which exposes humans to potentially flea bites in an enzootic cycle.
Burgess-Conforti, Jason R; Brye, Kristofor R; Miller, David M; Pollock, Erik D; Wood, Lisa S
2018-02-01
Environmental regulations mandate that sulfur dioxide (SO 2 ) be removed from the flue gases of coal-fired power plants, which results in the generation of flue gas desulfurization (FGD) by-products. These FGD by-products may be a viable soil amendment, but the large amounts of trace elements contained in FGD by-products are potentially concerning. The objective of this study was to evaluate the effects of land application of a high-Ca dry FGD (DFGD) by-product on trace elements in aboveground biomass and soil. A high-Ca DFGD by-product was applied once at a rate of 9 Mg ha -1 on May 18, 2015 to small plots with mixed-grass vegetation. Soil and biomass were sampled prior to application and several times thereafter. Aboveground dry matter and tissue As, Co, Cr, Hg, Se, U, and V concentrations increased (P < 0.05) following application, but did not differ (P > 0.05) from pre-application levels or the unamended control within 3 to 6 months of application. Soil pH in the amended treatment 6 months after application was greater (P < 0.05) than in the unamended control. Soil Ca, S, and Na contents also increased (P < 0.05), following by-product application compared to the unamended control. High-Ca DFGD by-products appear to be useful as a soil amendment, but cause at least a temporary increase in tissue concentrations of trace elements, which may be problematic for animal grazing situations.
Decreasing Phosphorus Loss in Tile-Drained Landscapes Using Flue Gas Desulfurization Gypsum.
King, K W; Williams, M R; Dick, W A; LaBarge, G A
2016-09-01
Elevated phosphorus (P) loading from agricultural nonpoint-source pollution continues to impair inland waterbodies throughout the world. The application of flue gas desulfurization (FGD) gypsum to agricultural fields has been suggested to decrease P loading because of its high calcium content and P sorbing potential. A before-after control-impact paired field experiment was used to examine the water quality effects of successive FGD gypsum applications (2.24 Mg ha; 1 ton acre each) to an Ohio field with high soil test P levels (>480 ppm Mehlich-3 P). Analysis of covariance was used to compare event discharge, dissolved reactive P (DRP), and total P (TP) concentrations and loadings in surface runoff and tile discharge between the baseline period (86 precipitation events) and Treatment Period 1 (42 precipitation events) and Treatment Period 2 (84 precipitation events). Results showed that, after the first application of FGD gypsum, event mean DRP and TP concentrations in treatment field tile water were significantly reduced by 21 and 10%, respectively, and DRP concentrations in surface runoff were significantly reduced by 14%; however, no significant reductions were noted in DRP or TP loading. After the second application, DRP and TP loads were significantly reduced in surface runoff (DRP, 41%; TP 40%), tile discharge (DRP, 35%; TP, 15%), and combined (surface + tile) discharge (DRP, 36%; TP, 38%). These findings indicate that surface application of FGD gypsum can be used as a tool to address elevated P concentrations and loadings in drainage waters. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Beaudoin, A L; Kitikoon, P; Schreiner, P J; Singer, R S; Sasipreeyajan, J; Amonsin, A; Gramer, M R; Pakinsee, S; Bender, J B
2014-08-01
Free-grazing ducks (FGD) have been associated with highly pathogenic avian influenza (HPAI) H5N1 outbreaks and may be a viral reservoir. In July-August 2010, we assessed influenza exposure of Thai FGD and risk factors thereof. Serum from 6254 ducks was analysed with enzyme-linked immunosorbent assay (ELISA) to detect antibodies to influenza A nucleoprotein (NP), and haemagglutinin H5 protein. Eighty-five per cent (5305 ducks) were seropositive for influenza A. Of the NP-seropositive sera tested with H5 assays (n = 1423), 553 (39%) were H5 ELISA positive and 57 (4%) suspect. Twelve per cent (74 of 610) of H5 ELISA-positive/suspect ducks had H5 titres ≥ 1 : 20 by haemagglutination inhibition. Risk factors for influenza A seropositivity include older age, poultry contact, flock visitors and older purchase age. Study flocks had H5 virus exposure as recently as March 2010, but no HPAI H5N1 outbreaks have been identified in Thailand since 2008, highlighting a need for rigorous FGD surveillance. © 2012 Blackwell Verlag GmbH.
Focus group discussion in mathematical physics learning
NASA Astrophysics Data System (ADS)
Ellianawati; Rudiana, D.; Sabandar, J.; Subali, B.
2018-03-01
The Focus Group Discussion (FGD) activity in Mathematical Physics learning has helped students perform the stages of problem solving reflectively. The FGD implementation was conducted to explore the problems and find the right strategy to improve the students' ability to solve the problem accurately which is one of reflective thinking component that has been difficult to improve. The research method used is descriptive qualitative by using single subject response in Physics student. During the FGD process, one student was observed of her reflective thinking development in solving the physics problem. The strategy chosen in the discussion activity was the Cognitive Apprenticeship-Instruction (CA-I) syntax. Based on the results of this study, it is obtained the information that after going through a series of stages of discussion, the students' reflective thinking skills is increased significantly. The scaffolding stage in the CA-I model plays an important role in the process of solving physics problems accurately. Students are able to recognize and formulate problems by describing problem sketches, identifying the variables involved, applying mathematical equations that accord to physics concepts, executing accurately, and applying evaluation by explaining the solution to various contexts.
Processing of aerosol particles within the Habshan pollution plume
NASA Astrophysics Data System (ADS)
Semeniuk, T. A.; Bruintjes, R.; Salazar, V.; Breed, D.; Jensen, T.; Buseck, P. R.
2015-03-01
The Habshan industrial site in the United Arab Emirates produces a regional-scale pollution plume associated with oil and gas processing, discharging high loadings of sulfates and chlorides into the atmosphere, which interact with the ambient aerosol population. Aerosol particles and trace gas chemistry at this site were studied on two flights in the summer of 2002. Measurements were collected along vertical plume profiles to show changes associated with atmospheric processing of particle and gas components. Close to the outlet stack, particle concentrations were over 10,000 cm-3, dropping to <2000 cm-3 in more dilute plume around 1500 m above the stack. Particles collected close to the stack and within the dilute plume were individually measured for size, morphology, composition, and mixing state using transmission electron microscopy coupled with energy-dispersive X-ray spectroscopy. Close to the stack, most coarse particles consisted of mineral dust and NaCl crystals from burning oil brines, while sulfate droplets dominated the fine mode. In more dilute plume, at least 1500 m above the stack, the particle spectrum was more diverse, with a significant increase in internally mixed particle types. Dilute plume samples consisted of coarse NaCl/silicate aggregates or NaCl-rich droplets, often with a sulfate component, while fine-fraction particles were of mixed cation sulfates, also internally mixed with nanospherical soot or silicates. Thus, both chloride and sulfate components of the pollution plume rapidly reacted with ambient mineral dust to form coated and aggregate particles, enhancing particle size, hygroscopicity, and reactivity of the coarse mode. The fine-fraction sulfate-bearing particles formed in the plume contribute to regional transport of sulfates, while coarse sulfate-bearing fractions locally reduced the SO2 loading through sedimentation. The chloride- and sulfate-bearing internally mixed particles formed in the plume markedly changed the reflectivity and scattering properties of the ambient aerosol population, as well as its hygroscopic and ice nucleation properties.
The effects of opening areas on solar chimney performance
NASA Astrophysics Data System (ADS)
Ling, L. S.; Rahman, M. M.; Chu, C. M.; Misaran, M. S. bin; Tamiri, F. M.
2017-07-01
To enhance natural ventilation at day time, solar chimney is one of the suitable options for topical country like Malaysia. Solar chimney creates air flow due to stack effect caused by temperature difference between ambient and inside wall. In the solar chimney, solar energy is harvested by the inner wall that cause temperature rise compare to ambient. Therefore, the efficiency of the solar chimney depends on the availability of solar energy as well as the solar intensity. In addition, it is very hard to get good ventilation at night time by using a solar chimney. To overcome this problem one of the suitable valid option is to integrate solar chimney with turbine ventilator. A new type of solar chimney is designed and fluid flow analyzed with the computational fluid dynamics (CFD) software. The aim of CFD and theoretical study are to investigate the effect of opening areas on modified solar chimney performance. The inlet and outlet area of solar chimney are varied from 0.0224m2 to 0.6m2 and 0.1m2 to 0.14m2 respectively based on the changes of inclination angle and gap between inner and outer wall. In the CFD study the constant heat flux is considered as 500W/m2. CFD result shows that there is no significant relation between opening areas and the air flow rate through solar chimney but the ratio between inlet and outlet is significant on flow performance. If the area ratio between inlet and outlet are equal to two or larger, the performance of the solar chimney is better than the solar chimney with ratio lesser than two. The solar chimney performance does not effect if the area ratio between inlet and outlet varies from 1 to 2. This result will be useful for design and verification of actual solar chimney performance.
Gurajada, Navya; Reed, Debra B; Taylor, Ashlee L
2017-12-13
Background: In US, approximately 23% of children between the ages of 2-5 years are overweight or obese. Parents need access to information to create healthy home environments for obesity prevention, yet participation for in-person education programs is challenging. Web-based interventions are promising educational tools due to 24/7 availability. However, information is limited on their development and evaluation. Design and Methods: This study reports on a rigorous development process that included six focus group discussions (FGD) with stakeholders (three FGD each with parents and teachers) to assess education needs and inform the development of the Jump2Health Website ™ by a multidisciplinary team. After development, the Website was evaluated by telephone interviews with stakeholders (five parents and six teachers) and reviewed by an expert panel of five Registered Dietitians. Results: Twenty Head Start parents and 22 Head Start teachers participated in the FGD. To address the needs identified by these stakeholders, the Website was designed to include components that were enabling and motivating, such as descriptions of health benefits by achieving the desired behaviours, short videos on easy meal preparation, and tip sheets on how to achieve healthy behaviours in easy, economical ways. Stakeholder evaluation of the Website indicated that the information was helpful, easy to use, and would be beneficial for parents. Conclusions: The development of Jump2Health Website ™ was strengthened by FGD with stakeholders that assessed educational needs. Interviews with stakeholders and an expert panel review showed that the Website may be an effective educational method to teach parents about healthy behaviours related to obesity prevention.
NASA Astrophysics Data System (ADS)
Pudasainee, Deepak; Kim, Jeong-Hun; Seo, Yong-Chil
2009-12-01
Regulatory control of mercury emission from anthropogenic sources has become a global concern in the recent past. Coal-fired power plants are one of the largest sources of anthropogenic mercury emission into the atmosphere. This paper summarizes the current reducing trend of mercury emission as co-beneficial effect by more stringent regulation changes to control primary air pollutants with introducing test results from the commercial coal-fired facilities and suggesting a guideline for future regulatory development in Korea. On average, mercury emission concentrations ranged 16.3-2.7 μg Sm -3, 2.4-1.1 μg Sm -3, 3.1-0.7 μg Sm -3 from anthracite coal-fired power plants equipped with electrostatic precipitator (ESP), bituminous coal-fired power plants with ESP + flue gas desulphurization (FGD) and bituminous coal-fired power plants with selective catalytic reactor (SCR) + cold side (CS) - ESP + wet FGD, respectively. Among the existing air pollution control devices, the best configuration for mercury removal in coal-fired power plants was SCR + CS - ESP + wet FGD, which were installed due to the stringent regulation changes to control primary air pollutants emission such as SO 2, NOx and dust. It was estimated that uncontrolled and controlled mercury emission from coal-fired power plants as 10.3 ton yr -1 and 3.2 ton yr -1 respectively. After the installation of ESP, FGD and SCR system, following the enforcement of the stringent regulation, 7.1 ton yr -1 of mercury emission has been reduced (nearly 69%) from coal-fired power plants as a co-benefit control. Based on the overall study, a sample guideline including emission limits were suggested which will be applied to develop a countermeasure for controlling mercury emission from coal-fired power plants.
Thanh, B D; Lefevre, T
2001-02-01
The impact pathway approach (IPA) is used to estimate quantitatively the level of health effects caused by particulate matter (PM10) and sulfur dioxide (SO2) emission from a lignite-fired power plant located in the Mae Moh area in northern region of Thailand. Health benefits are then assessed by comparing the levels of estimated health impacts without and with the installation of the flue gas desulfurization (FGD) equipment. The US EPA industrial source complex model is used to model air pollution dispersion at the local scale, and the sector average limited mixing meso-scale model is used to model air pollution transport at the regional scale. The quantification of the health end points in physical terms is carried out using the dose-response functions established recently for the population in Bangkok, Thailand. Monetarization of these effects is based on the benefit transfer method with appropriate adjustment. Finally, it has been found that the installation of the FGD to control SO2 emission at Mae Moh significantly reduces adverse health effects not only on the population living near the power plant but also all over the country. A FGD unit installed at the 300-MW power unit can result, on average, in 16 fewer cases of acute mortality, 12 fewer cases of respiratory and cardiac hospital admissions, and almost 354,000 fewer days with acute respiratory symptoms annually. In monetary terms this benefit is equivalent to US $18.2 million (1995 prices) per annum. This benefit is much higher than the annualized investment and operation costs of FGD (US $7.4 million/yr). Copyright 2001 Springer-Verlag
Satisfaction of Nigerian stroke survivors with outpatient physiotherapy care.
Olaleye, Olubukola A; Hamzat, Talhatu K; Akinrinsade, Marvellous A
2017-01-01
To investigate the satisfaction of stroke survivors with outpatient physiotherapy care. Sixty stroke survivors were surveyed using the European Physiotherapy Treatment Outpatient Satisfaction Survey (EPTOPS). Focus group discussion (FGD) was also conducted with four stroke survivors from the same sample. Data were analyzed using the Kruskal Wallis test and Spearman's correlation coefficients at p = 0.05. FGD was transcribed and thematically analyzed. Nearly all the participants (98.3%) indicated one of good, very good, and excellent improvement in their clinical conditions with physiotherapy. Majority expressed satisfaction with their physiotherapy care, the modal response being very good (59.3%). Patients' satisfaction and socio-demographics were not significantly correlated (p > 0.05). Overarching themes from FGD were physiotherapy in stroke rehabilitation, satisfaction with physiotherapy care, cost, and lack of continuity of care as sources of dissatisfaction. Physiotherapists' demeanor was a facilitator of satisfaction. The stroke survivors were generally satisfied with outpatient physiotherapy care. However, lack of continuity and cost of care were sources of dissatisfaction among patients. Delivery of physiotherapy to stroke survivors in Nigeria should be structured to allow for continuity of care as this may enhance satisfaction. Implementation of inexpensive rehabilitation strategies may help reduce cost of physiotherapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grant L. Hawkes; James E. O'Brien; Greg Tao
2011-11-01
A three-dimensional computational fluid dynamics (CFD) electrochemical model has been created to model high-temperature electrolysis cell performance and steam electrolysis in an internally manifolded planar solid oxide electrolysis cell (SOEC) stack. This design is being evaluated at the Idaho National Laboratory for hydrogen production from nuclear power and process heat. Mass, momentum, energy, and species conservation and transport are provided via the core features of the commercial CFD code FLUENT. A solid-oxide fuel cell (SOFC) model adds the electrochemical reactions and loss mechanisms and computation of the electric field throughout the cell. The FLUENT SOFC user-defined subroutine was modified formore » this work to allow for operation in the SOEC mode. Model results provide detailed profiles of temperature, operating potential, steam-electrode gas composition, oxygen-electrode gas composition, current density and hydrogen production over a range of stack operating conditions. Single-cell and five-cell results will be presented. Flow distribution through both models is discussed. Flow enters from the bottom, distributes through the inlet plenum, flows across the cells, gathers in the outlet plenum and flows downward making an upside-down ''U'' shaped flow pattern. Flow and concentration variations exist downstream of the inlet holes. Predicted mean outlet hydrogen and steam concentrations vary linearly with current density, as expected. Effects of variations in operating temperature, gas flow rate, oxygen-electrode and steam-electrode current density, and contact resistance from the base case are presented. Contour plots of local electrolyte temperature, current density, and Nernst potential indicate the effects of heat transfer, reaction cooling/heating, and change in local gas composition. Results are discussed for using this design in the electrolysis mode. Discussion of thermal neutral voltage, enthalpy of reaction, hydrogen production, cell thermal efficiency, cell electrical efficiency, and Gibbs free energy are discussed and reported herein.« less
NASA Astrophysics Data System (ADS)
Bellaiche, Gilbert; Loncke, Lies; Gaullier, Virginie; Mascle, Jean; Courp, Thierry; Moreau, Alain; Radan, Silviu; Sardou, Olivier
2001-10-01
The meandrous leveed channels of the Nile Cone show clear evidence of avulsions. Their sedimentary architecture is founded on numerous stacked lens-shaped acoustic units. In the areas of the distal fan, lobe deposits are apparent from multichannel imagery. Huge debris flow deposits, sometimes associated with pockmarks, are recognized. Mud volcanoes and gas seeping are closely associated with faulting. In the East, a very long north-trending channel, originating from the Egyptian coast, merges with a network of channels, very probably originating from the Levantine coasts. Both networks outlet in the sedimentary basin located south of Cyprus.
Mao, Yumei; Li, Xiaping; Dick, Warren A; Chen, Liming
2016-07-01
Salinization and sodicity are obstacles for vegetation reconstruction of coastal tidal flat soils. A study was conducted with flue gas desulfurization (FGD)-gypsum applied at rates of 0, 15, 30, 45 and 60Mg/ha to remediate tidal flat soils of the Yangtze River estuary. Exchangeable sodium percentage (ESP), exchangeable sodium (ExNa), pH, soluble salt concentration, and composition of soluble salts were measured in 10cm increments from the surface to 30cm depth after 6 and 18months. The results indicated that the effect of FGD-gypsum is greatest in the 0-10cm mixing soil layer and 60Mg/ha was the optimal rate that can reduce the ESP to below 6% and decrease soil pH to neutral (7.0). The improvement effect was reached after 6months, and remained after 18months. The composition of soluble salts was transformed from sodic salt ions mainly containing Na(+), HCO3(-)+CO3(2-) and Cl(-) to neutral salt ions mainly containing Ca(2+) and SO4(2-). Non-halophyte plants were survived at 90%. The study demonstrates that the use of FGD-gypsum for remediating tidal flat soils is promising. Copyright © 2016. Published by Elsevier B.V.
Ahn, C; Mitsch, W J
2001-01-01
Small-scale (1 m2) wetland mesocosm experiments were conducted over two consecutive growing seasons to investigate the effects on soil and leachate chemistry of using a recycled coal combustion product as a liner. The coal combustion product used as a liner consisted of flue gas desulfurization (FGD) by-products and fly ash. This paper provides the chemical characteristics of mesocosm soil and leachate after 2 yr of experimentation. Arsenic, Ca, and pH were higher in FGD-lined mesocosm surface soil relative to unlined mesocosms. Aluminum was higher in the soils of unlined mesocosms relative to FGD-lined mesocosms. No significant difference of potentially phytotoxic B was observed between lined and unlined mesocosms in the soil. Higher pH, conductivity, and concentrations of Al, B, Ca, K, and S (SO4-S) were observed in leachate from lined mesocosms compared with unlined controls while Fe, Mg, and Mn were higher in leachate from unlined mesocosms. Concentrations of most elements analyzed in the leachate were below national primary and secondary drinking water standards after 2 yr of experimentation. Initially high pH and soluble salt concentrations measured in the leachate from the lined mesocosms may indicate the reason for early effects noted on the development of wetland vegetation in the mesocosms.
Study of boron behaviour in two Spanish coal combustion power plants.
Ochoa-González, Raquel; Cuesta, Aida Fuente; Córdoba, Patricia; Díaz-Somoano, Mercedes; Font, Oriol; López-Antón, M Antonia; Querol, Xavier; Martínez-Tarazona, M Rosa; Giménez, Antonio
2011-10-01
A full-scale field study was carried out at two Spanish coal-fired power plants equipped with electrostatic precipitator (ESP) and wet flue gas desulfurisation (FGD) systems to investigate the distribution of boron in coals, solid by-products, wastewater streams and flue gases. The results were obtained from the simultaneous sampling of solid, liquid and gaseous streams and their subsequent analysis in two different laboratories for purposes of comparison. Although the final aim of this study was to evaluate the partitioning of boron in a (co-)combustion power plant, special attention was paid to the analytical procedure for boron determination. A sample preparation procedure was optimised for coal and combustion by-products to overcome some specific shortcomings of the currently used acid digestion methods. In addition boron mass balances and removal efficiencies in ESP and FGD devices were calculated. Mass balance closures between 83 and 149% were obtained. During coal combustion, 95% of the incoming boron was collected in the fly ashes. The use of petroleum coke as co-combustible produced a decrease in the removal efficiency of the ESP (87%). Nevertheless, more than 90% of the remaining gaseous boron was eliminated via the FGD in the wastewater discharged from the scrubber, thereby causing environmental problems. Copyright © 2011 Elsevier Ltd. All rights reserved.
Nisita, Cristiana; Cortopassi, Sonia; Corretti, Giorgio; Gambaccini, Dario; De Bortoli, Nicola; Fani, Bernardo; Simonetti, Natalia; Ricchiuti, Angelo; Dell'Osso, Liliana; Marchi, Santino; Bellini, Massimo
2017-01-01
Background and Aims Functional gastrointestinal disorders (FGDs) are multifactorial disorders of the gut-brain interaction. This study investigated the prevalence of Axis I and spectrum disorders in patients with FGD and established the link between FGDs and psychopathological dimensions. Methods A total of 135 consecutive patients with FGD were enrolled. The symptoms' severity was evaluated using questionnaires, while the psychiatric evaluation by clinical interviews established the presence/absence of mental (Diagnostic and Statistical Manual—4th edition, Axis I Diagnosis) or spectrum disorders. Results Of the 135 patients, 42 (32.3%) had functional dyspepsia, 52 (40.0%) had irritable bowel syndrome, 21 (16.2%) had functional bloating, and 20 (15.4%) had functional constipation. At least one psychiatric disorder was present in 46.9% of the patients, while a suprathreshold panic spectrum was present in 26.2%. Functional constipation was associated with depressive disorders (p < 0.05), while functional dyspepsia was related to the current major depressive episode (p < 0.05). Obsessive-compulsive spectrum was correlated with the presence of functional constipation and irritable bowel syndrome (p < 0.05). Conclusion The high prevalence of subthreshold psychiatric symptomatology in patients with FGD, which is likely to influence the expression of gastrointestinal symptoms, suggested the usefulness of psychological evaluation in patients with FGDs. PMID:29213280
Solid oxide fuel cell with monolithic core
McPheeters, Charles C.; Mrazek, Franklin C.
1988-01-01
A solid oxide fuel cell in which fuel and oxidant gases undergo an electrochemical reaction to produce an electrical output includes a monolithic core comprised of a corrugated conductive sheet disposed between upper and lower generally flat sheets. The corrugated sheet includes a plurality of spaced, parallel, elongated slots which form a series of closed, linear, first upper and second lower gas flow channels with the upper and lower sheets within which a fuel gas and an oxidant gas respectively flow. Facing ends of the fuel cell are generally V-shaped and provide for fuel and oxidant gas inlet and outlet flow, respectively, and include inlet and outlet gas flow channels which are continuous with the aforementioned upper fuel gas and lower oxidant gas flow channels. The upper and lower flat sheets and the intermediate corrugated sheet are preferably comprised of ceramic materials and are securely coupled together such as by assembly in the green state and sintering together during firing at high temperatures. A potential difference across the fuel cell, or across a stacked array of similar fuel cells, is generated when an oxidant gas such as air and a fuel such as hydrogen gas is directed through the fuel cell at high temperatures, e.g., between 700.degree. C. and 1100.degree. C.
Solid oxide fuel cell with monolithic core
McPheeters, C.C.; Mrazek, F.C.
1988-08-02
A solid oxide fuel cell in which fuel and oxidant gases undergo an electrochemical reaction to produce an electrical output includes a monolithic core comprised of a corrugated conductive sheet disposed between upper and lower generally flat sheets. The corrugated sheet includes a plurality of spaced, parallel, elongated slots which form a series of closed, linear, first upper and second lower gas flow channels with the upper and lower sheets within which a fuel gas and an oxidant gas respectively flow. Facing ends of the fuel cell are generally V-shaped and provide for fuel and oxidant gas inlet and outlet flow, respectively, and include inlet and outlet gas flow channels which are continuous with the aforementioned upper fuel gas and lower oxidant gas flow channels. The upper and lower flat sheets and the intermediate corrugated sheet are preferably comprised of ceramic materials and are securely coupled together such as by assembly in the green state and sintering together during firing at high temperatures. A potential difference across the fuel cell, or across a stacked array of similar fuel cells, is generated when an oxidant gas such as air and a fuel such as hydrogen gas is directed through the fuel cell at high temperatures, e.g., between 700 C and 1,100 C. 8 figs.
Compliance to Gutka ban and other provisons of COTPA in Mumbai.
Pimple, S; Gunjal, S; Mishra, G A; Pednekar, M S; Majmudar, P; Shastri, S S
2014-12-01
Cigarettes and other tobacco products act 2003 (COTPA) is the principal law governing tobacco control in India. Government of Maharashtra in one of its landmark decisions also banned manufacturing, sale and distribution of gutka and pan masala since July 2012. The desired impact and level of enforcement of the COTPA legislation and the gutka and pan masala ban in Maharashtra State, however, needs assessment. Among the many provisions within COTPA, the present study seeks to assess compliance to implementation and enforcement of Section 5 and 6 of COTPA including compliance to gutka and pan masala ban in Mumbai, India. Six educational institutes (EI) within the Mumbai metropolitan region were selected in a two stage random sampling process. Area around each EI was manually mapped and all the tobacco products selling outlets with in the 100 yards distance were listed by trained Field Social Investigators and were observed to determine compliance for Section 5 and Section 6 of the COTPA legislation and for gutka and pan masala ban. The vendors/shop owners manning these outlets were also interviewed for their personal sociodemographic details, self-tobacco use, awareness and perception about ill-effects of tobacco and existing tobacco control legislation in the country. A total of 222 tobacco retail outlets were listed within 100 yards of the EI in violation to the provisions of Section 6 of COTPA, of which 72 (32.4%) were selling tobacco products on mobile structures. About 53.2% of the tobacco vendors were also users of some form of tobacco. Whereas, nearly 217 (97.7%) vendors were aware about the gutka and pan masala ban in the State, only 48.2% were aware about the existence of COTPA legislation. None of the EI had a display board prohibiting the sale of tobacco products within a radius of 100 yards of their EI. Only 56.3% tobacco outlets had complied with the mandatory warning display boards indicating tobacco products will not be sold to people below 18 years of age. With regards to point of sale advertisement only 25.2% compliance was noted for display of health warning boards at the point of sale. Nearly 48.6% tobacco outlets exhibited >2 display boards and another 43.2% exhibited hoardings with brand pack photo, brand name in violation to the provision under Section 5. Violation by visible stacking and open display of tobacco products for sale was observed at 51.3% of tobacco outlets. While 41% of tobacco outlets were found displaying gutka and pan masala packets in violation to the ban. Enacting of the law without robust measures for enforcement has led to widespread noncompliance to the provisions with in the tobacco control legislation in the metropolitan city of Mumbai. Strong and sustainable measures needs to be incorporated both by civic administration and public health departments for its forceful implementation.
Specifically Designed Constructed Wetlands: A Novel Treatment Approach for Scrubber Wastewater
DOE Office of Scientific and Technical Information (OSTI.GOV)
John H. Rodgers Jr; James W. Castle; Chris Arrington: Derek Eggert
2005-09-01
A pilot-scale wetland treatment system was specifically designed and constructed at Clemson University to evaluate removal of mercury, selenium, and other constituents from flue gas desulfurization (FGD) wastewater. Specific objectives of this research were: (1) to measure performance of a pilot-scale constructed wetland treatment system in terms of decreases in targeted constituents (Hg, Se and As) in the FGD wastewater from inflow to outflow; (2) to determine how the observed performance is achieved (both reactions and rates); and (3) to measure performance in terms of decreased bioavailability of these elements (i.e. toxicity of sediments in constructed wetlands and toxicity ofmore » outflow waters from the treatment system). Performance of the pilot-scale constructed wetland treatment systems was assessed using two criteria: anticipated NPDES permit levels and toxicity evaluations using two sentinel toxicity-testing organisms (Ceriodaphnia dubia and Pimephales promelas). These systems performed efficiently with varied inflow simulations of FGD wastewaters removing As, Hg, and Se concentrations below NPDES permit levels and reducing the toxicity of simulated FGD wastewater after treatment with the constructed wetland treatment systems. Sequential extraction procedures indicated that these elements (As, Hg, and Se) were bound to residual phases within sediments of these systems, which should limit their bioavailability to aquatic biota. Sediments collected from constructed wetland treatment systems were tested to observe toxicity to Hyalella azteca or Chironomus tetans. Complete survival (100%) was observed for H. azteca in all cells of the constructed wetland treatment system and C. tentans had an average of 91% survival over the three treatment cells containing sediments. Survival and growth of H. azteca and C. tentans did not differ significantly between sediments from the constructed wetland treatment system and controls. Since the sediments of the constructed wetland treatment system are repositories for As, Hg, and Se and the bioavailability of these elements decreased after deposition, the pilot-scale constructed wetland treatment system contributed significantly to mitigation of risks to aquatic life from these elements.« less
Aarskog-Scott syndrome: clinical update and report of nine novel mutations of the FGD1 gene.
Orrico, A; Galli, L; Faivre, L; Clayton-Smith, J; Azzarello-Burri, S M; Hertz, J M; Jacquemont, S; Taurisano, R; Arroyo Carrera, I; Tarantino, E; Devriendt, K; Melis, D; Thelle, T; Meinhardt, U; Sorrentino, V
2010-02-01
Mutations in the FGD1 gene have been shown to cause Aarskog-Scott syndrome (AAS), or facio-digito-genital dysplasia (OMIM#305400), an X-linked disorder characterized by distinctive genital and skeletal developmental abnormalities with a broad spectrum of clinical phenotypes. To date, 20 distinct mutations have been reported, but little phenotypic data are available on patients with molecularly confirmed AAS. In the present study, we report on our experience of screening for mutations in the FGD1 gene in a cohort of 60 European patients with a clinically suspected diagnosis of AAS. We identified nine novel mutations in 11 patients (detection rate of 18.33%), including three missense mutations (p.R402Q; p.S558W; p.K748E), four truncating mutations (p.Y530X; p.R656X; c.806delC; c.1620delC), one in-frame deletion (c.2020_2022delGAG) and the first reported splice site mutation (c.1935+3A>C). A recurrent mutation (p.R656X) was detected in three independent families. We did not find any evidence for phenotype-genotype correlations between type and position of mutations and clinical features. In addition to the well-established phenotypic features of AAS, other clinical features are also reported and discussed. Copyright 2010 Wiley-Liss, Inc.
Multiple Rap1 effectors control Epac1-mediated tightening of endothelial junctions.
Pannekoek, Willem-Jan; Vliem, Marjolein J; Bos, Johannes L
2018-02-17
Epac1 and Rap1 mediate cAMP-induced tightening of endothelial junctions. We have previously found that one of the mechanisms is the inhibition of Rho-mediated tension in radial stress fibers by recruiting the RhoGAP ArhGAP29 in a complex containing the Rap1 effectors Rasip1 and Radil. However, other mechanisms have been proposed as well, most notably the induction of tension in circumferential actin cables by Cdc42 and its GEF FGD5. Here, we have investigated how Rap1 controls FGD5/Cdc42 and how this interconnects with Radil/Rasip1/ArhGAP29. Using endothelial barrier measurements, we show that Rho inhibition is not sufficient to explain the barrier stimulating effect of Rap1. Indeed, Cdc42-mediated tension is induced at cell-cell contacts upon Rap1 activation and this is required for endothelial barrier function. Depletion of potential Rap1 effectors identifies AF6 to mediate Rap1 enhanced tension and concomitant Rho-independent barrier function. When overexpressed in HEK293T cells, AF6 is found in a complex with FGD5 and Radil. From these results we conclude that Rap1 utilizes multiple pathways to control tightening of endothelial junctions, possibly through a multiprotein effector complex, in which AF6 functions to induce tension in circumferential actin cables.
NASA Astrophysics Data System (ADS)
Zhang, Liang; Lin, Xiaojuan; Wang, Jinting; Jiang, Feng; Wei, Li; Chen, Guanghao; Hao, Xiaodi
2016-07-01
Biological sulfate-reducing bacteria (SRB) may be effective in removing toxic lead and mercury ions (Pb(II) and Hg(II)) from wet flue gas desulfurization (FGD) wastewater through anaerobic sulfite reduction. To confirm this hypothesis, a sulfite-reducing up-flow anaerobic sludge blanket reactor was set up to treat FGD wastewater at metal loading rates of 9.2 g/m3-d Pb(II) and 2.6 g/m3-d Hg(II) for 50 days. The reactor removed 72.5 ± 7% of sulfite and greater than 99.5% of both Hg(II) and Pb(II). Most of the removed lead and mercury were deposited in the sludge as HgS and PbS. The contribution of cell adsorption and organic binding to Pb(II) and Hg(II) removal was 20.0 ± 0.1% and 1.8 ± 1.0%, respectively. The different bioavailable concentration levels of lead and mercury resulted in different levels of lethal toxicity. Cell viability analysis revealed that Hg(II) was less toxic than Pb(II) to the sludge microorganisms. In the batch tests, increasing the Hg(II) feeding concentration increased sulfite reduction rates. In conclusion, a sulfite-reducing reactor can efficiently remove sulfite, Pb(II) and Hg(II) from FGD wastewater.
Zhang, Liang; Lin, Xiaojuan; Wang, Jinting; Jiang, Feng; Wei, Li; Chen, Guanghao; Hao, Xiaodi
2016-01-01
Biological sulfate-reducing bacteria (SRB) may be effective in removing toxic lead and mercury ions (Pb(II) and Hg(II)) from wet flue gas desulfurization (FGD) wastewater through anaerobic sulfite reduction. To confirm this hypothesis, a sulfite-reducing up-flow anaerobic sludge blanket reactor was set up to treat FGD wastewater at metal loading rates of 9.2 g/m3-d Pb(II) and 2.6 g/m3-d Hg(II) for 50 days. The reactor removed 72.5 ± 7% of sulfite and greater than 99.5% of both Hg(II) and Pb(II). Most of the removed lead and mercury were deposited in the sludge as HgS and PbS. The contribution of cell adsorption and organic binding to Pb(II) and Hg(II) removal was 20.0 ± 0.1% and 1.8 ± 1.0%, respectively. The different bioavailable concentration levels of lead and mercury resulted in different levels of lethal toxicity. Cell viability analysis revealed that Hg(II) was less toxic than Pb(II) to the sludge microorganisms. In the batch tests, increasing the Hg(II) feeding concentration increased sulfite reduction rates. In conclusion, a sulfite-reducing reactor can efficiently remove sulfite, Pb(II) and Hg(II) from FGD wastewater. PMID:27455890
Proceedings: 1995 SO{sub 2} control symposium. Volume 1, Sessions 1, 2, 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-01
Cosponsored by EPRI, DOE, and EPA, this conference provided a forum for the exchange of economic, technical, and regulatory information on sulfur dioxide control technology. From March 28--31, 1995, participants presented 100 technical papers to an audience of 525 people from around the world. Given in thirteen technical sessions, the papers included regulatory and economic issues, wet and dry SO{sub 2} control processes, emerging technologies, and experience with Clean Air Act Amendments (CAAA) Phase I startups. The fifteenth in a series of symposia over the past two decades, the conference included these key points: the domestic flue gas desulfurization (FGD)more » market is likely to be modest over the next ten years, with most activity overseas; FGD awards could reach over $4 billion a year from 1996--2003, with more than half going to Eastern Europe and Asia; worldwide, at the start of 1994, FGD systems were installed on 609 coal-fired power plants; the average capital cost for Phase I retrofits has been $233/kW; and, trends point to simpler designs, such as towers that operate at higher gas velocities with fewer internals. Published proceedings from these regularly scheduled symposia are valuable resources for engineers and utility planners who need up-to-date information to comply with clean air legislation. Selected papers have been processed separately for inclusion in the Energy Science and Technology database.« less
Proceedings: 1995 SO{sub 2} control symposium. Volume 4, Sessions Ba, 8b
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-01
Cosponsored by EPRI, DOE, and EPA, this conference provided a forum for the exchange of economic, technical, and regulatory information on sulfur dioxide control technology. From March 28--31, 1995, participants presented 100 technical papers to an audience of 525 people from around the world. Given in thirteen technical sessions, the papers included regulatory and economic issues, wet and dry SO{sub 2} control processes, emerging technologies, and experience with Clean Air Act Amendments (CAAA) Phase I startups. The fifteenth in a series of symposia over the past two decades, the conference included these key points: the domestic flue gas desulfurization (FGD)more » market is likely to be modest over the next ten years, with most activity overseas; FGD awards could reach over $4 billion a year from 1996--2003, with more than half going to Eastern Europe and Asia; worldwide, at the start of 1994, FGD systems were installed on 609 coal-fired power plants; the average capital cost for Phase I retrofits has been $233/kW; and, trends point to simpler designs, such as towers that operate at higher gas velocities with fewer internals. Published proceedings from these regularly scheduled symposia are valuable resources for engineers and utility planners who need up-to-date information to comply with clean air legislation. Selected papers have been processed separately for inclusion in the Energy Science and Technology database.« less
PCDD/F emissions during startup and shutdown of a hazardous waste incinerator.
Li, Min; Wang, Chao; Cen, Kefa; Ni, Mingjiang; Li, Xiaodong
2017-08-01
Compared with municipal solid waste incineration, studies on the PCDD/F emissions of hazardous waste incineration (HWI) under transient conditions are rather few. This study investigates the PCDD/F emission level, congener profile and removal efficiency recorded during startup and shutdown by collecting flue gas samples at the bag filter inlet and outlet and at the stack. The PCDD/F concentration measured in the stack gas during startup and shutdown were 0.56-4.16 ng I-TEQ Nm -3 and 1.09-3.36 ng I-TEQ Nm -3 , respectively, far exceeding the present codes in China. The total amount of PCDD/F emissions, resulting from three shutdown-startup cycles of this HWI-unit is almost equal to that generated during one year under normal operating conditions. Upstream the filter, the PCDD/F in the flue gas is mainly in the particle phase; however, after being filtered PCDD/F prevails in the gas phase. The PCDD/F fraction in the gas phase even exceeds 98% after passing through the alkaline scrubber. Especially higher chlorinated PCDD/F accumulate on inner walls of filters and ducts during these startup periods and could be released again during normal operation, significantly increasing PCDD/F emissions. Copyright © 2017. Published by Elsevier Ltd.
STGSTK- PREDICTING MULTISTAGE AXIAL-FLOW COMPRESSOR PERFORMANCE BY A MEANLINE STAGE-STACKING METHOD
NASA Technical Reports Server (NTRS)
Steinke, R. J.
1994-01-01
The STGSTK computer program was developed for predicting the off-design performance of multistage axial-flow compressors. The axial-flow compressor is widely used in aircraft engines. In addition to its inherent advantage of high mass flow per frontal area, it can exhibit very good aerodynamic performance. However, good aerodynamic performance over an acceptable range of operating conditions is not easily attained. STGSTK provides an analytical tool for the development of new compressor designs. The simplicity of a one-dimensional compressible flow model enables the stage-stacking method used in STGSTK to have excellent convergence properties and short computer run times. Also, the simplicity of the model makes STGSTK a manageable code that eases the incorporation, or modification, of empirical correlations directly linked to test data. Thus, the user can adapt the code to meet varying design needs. STGSTK uses a meanline stage-stacking method to predict off-design performance. Stage and cumulative compressor performance is calculated from representative meanline velocity diagrams located at rotor inlet and outlet meanline radii. STGSTK includes options for the following: 1) non-dimensional stage characteristics may be input directly or calculated from stage design performance input, 2) stage characteristics may be modified for off-design speed and blade reset, and 3) rotor design deviation angle may be modified for off-design flow, speed, and blade setting angle. Many of the code's options use correlations that are normally obtained from experimental data. The STGSTK user may modify these correlations as needed. This program is written in FORTRAN IV for batch execution and has been implemented on an IBM 370 series computer with a central memory requirement of approximately 85K of 8 bit bytes. STGSTK was developed in 1982.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milton Wu; Paul Yuran
2006-12-31
Universal Aggregates LLC (UA) was awarded a cost sharing Co-operative Agreement from the Department of Energy (DOE) through the Power Plant Improvement Initiative Program (PPII) to design, construct and operate a lightweight aggregate manufacturing plant at the Birchwood Power Facility in King George, Virginia in October 2001. The Agreement was signed in November 2002. The installation and start-up expenses for the Birchwood Aggregate Facility are $19.5 million. The DOE share is $7.2 million (37%) and the UA share is $12.3 million (63%). The original project team consists of UA, SynAggs, LLC, CONSOL Energy Inc. and P. J. Dick, Inc. Usingmore » 115,000 ton per year of spray dryer ash (SDA), a dry FGD by-product from the power station, UA will produce 167,000 tons of manufactured lightweight aggregate for use in production of concrete masonry units (CMU). Manufacturing aggregate from FGD by-products can provide an economical high-volume use and substantially expand market for FGD by-products. Most of the FGD by-products are currently disposed of in landfills. Construction of the Birchwood Aggregate Facility was completed in March 2004. Operation startup was begun in April 2004. Plant Integration was initiated in December 2004. Integration includes mixing, extrusion, curing, crushing and screening. Lightweight aggregates with proper size gradation and bulk density were produced from the manufacturing aggregate plant and loaded on a stockpile for shipment. The shipped aggregates were used in a commercial block plant for CMU production. However, most of the production was made at low capacity factors and for a relatively short time in 2005. Several areas were identified as important factors to improve plant capacity and availability. Equipment and process control modifications and curing vessel clean up were made to improve plant operation in the first half of 2006. About 3,000 tons of crushed aggregate was produced in August 2006. UA is continuing to work to improve plant availability and throughput capacity and to produce quality lightweight aggregate for use in commercial applications.« less
Vu, Michael M. K.; Jameson, Nora E.; Masuda, Stuart J.; Lin, Dana; Larralde-Ridaura, Rosa; Lupták, Andrej
2012-01-01
SUMMARY Aptamers are structured macromolecules in vitro evolved to bind molecular targets, whereas in nature they form the ligand-binding domains of riboswitches. Adenosine aptamers of a single structural family were isolated several times from random pools but they have not been identified in genomic sequences. We used two unbiased methods, structure-based bioinformatics and human genome-based in vitro selection, to identify aptamers that form the same adenosine-binding structure in a bacterium, and several vertebrates, including humans. Two of the human aptamers map to introns of RAB3C and FGD3 genes. The RAB3C aptamer binds ATP with dissociation constants about ten times lower than physiological ATP concentration, while the minimal FGD3 aptamer binds ATP only co-transcriptionally. PMID:23102219
TT, Chung; TR, Webb; LF, Chan; SN, Cooray; LA, Metherell; PJ, King; JP, Chapple; AJL, Clark
2008-01-01
Context: There are at least twenty-four missense, non-conservative mutations found in the ACTH receptor (Melanocortin 2 receptor, MC2R) which have been associated with the autosomal recessive disease Familial Glucocorticoid Deficiency (FGD) type 1. The characterization of these mutations has been hindered by difficulties in establishing a functional heterologous cell transfection system for MC2R. Recently the melanocortin 2 receptor accessory protein (MRAP) was identified as essential for trafficking of MC2R to the cell surface; therefore a functional characterization of MC2R mutations is now possible. Objective: To elucidate the molecular mechanisms responsible for defective MC2R function in FGD. Methods: Stable cell lines expressing human MRAPα were established and transiently transfected with wild-type or mutant MC2R. Functional characterization of mutant MC2R was performed using a cell surface expression assay, a cAMP reporter assay, confocal microscopy and co-immunoprecipitation of MRAPα. Results: Two thirds of all MC2R mutations had a significant reduction in cell surface trafficking even though MRAPα interacted with all mutants. Analysis of those mutant receptors that reached the cell surface indicated that 4/6 failed to signal, following stimulation with ACTH. Conclusion: The majority of MC2R mutations found in FGD fail to function because they fail to traffic to the cell surface. PMID:18840636
Zacharia, Balaji; Paul, Manu; Thanveeruddin Sherule, Mohammed
2016-01-01
Total knee replacement (TKR) results in an excellent outcome in terms of pain relief. The reporting of outcomes was traditionally focused on implant survivorship and objective outcomes such as range of motion, knee stability, and radiographic alignment. However, patients and doctors had differing perceptions of all domains of outcome, especially subjective quality of life domains such as emotions and social functioning. In this study, we tried to find out the expectations of Indian patients regarding TKR and assess the level of satisfaction among our patients from their view point using focus group discussion (FGD), and whether these expectations have an impact on outcomes and patient satisfaction. This study was conducted in the Department of Orthopedics, Government Medical College, Kozhikode, Kerala, India, in November 2014. Patients between the ages 60 and 65 years who met inclusion criteria were selected. A total of 50 patients were selected for FGDs. Among them, 42 patients participated in FGD. The remaining eight did not appear for the discussion. A total of four FGD sessions were conducted. It was found that there is a discrepancy between the satisfaction levels of patient and surgeon. There is a difference in satisfaction level achieved depending on socioeconomic, geographic, and cultural characteristics. Newer methods of TKR outcome assessment combining radiological outcome, surgeon-based assessment, and patient satisfaction based on their socioeconomic status and cultural characteristics should be developed for different populations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nick Degenstein; Minish Shah; Doughlas Louie
2012-05-01
The goal of this project is to develop a near-zero emissions flue gas purification technology for existing PC (pulverized coal) power plants that are retrofitted with oxy-combustion technology. The objective of Task 2 of this project was to evaluate an alternative method of SOx, NOx and Hg removal from flue gas produced by burning high sulfur coal in oxy-combustion power plants. The goal of the program was not only to investigate a new method of flue gas purification but also to produce useful acid byproduct streams as an alternative to using a traditional FGD and SCR for flue gas processing.more » During the project two main constraints were identified that limit the ability of the process to achieve project goals. 1) Due to boiler island corrosion issues >60% of the sulfur must be removed in the boiler island with the use of an FGD. 2) A suitable method could not be found to remove NOx from the concentrated sulfuric acid product, which limits sale-ability of the acid, as well as the NOx removal efficiency of the process. Given the complexity and safety issues inherent in the cycle it is concluded that the acid product would not be directly saleable and, in this case, other flue gas purification schemes are better suited for SOx/NOx/Hg control when burning high sulfur coal, e.g. this project's Task 3 process or a traditional FGD and SCR.« less
Kotwani, Anita; Wattal, Chand; Joshi, P C; Holloway, Kathleen
2016-01-01
To explore the perceptions and knowledge of school teachers and students about antibiotic use, resistance, and suggestions for practical interventions for the rational use of antibiotics. Five focus group discussions (FGDs) with high school students (Class: 9-11) and five with teachers were conducted in two private and three public schools (one teacher and one student FGD per school) in five municipal wards of Delhi. Qualitative data on antibiotic knowledge, resistance, and behaviors with respect to antibiotics use were collected. There were 4-8 persons per teacher FGD and 15-20 persons per student FGD. FGDs were analyzed using "thematic analyses." Students had poor knowledge regarding antibiotics and antibiotic resistance, while only some teachers had a basic understanding. Four broad themes needing attention emerged: definition of antibiotic and antibiotic resistance, antibiotic use behavior, doctor-patient relationship, and interventional strategies suggested to curtail the misuse of antibiotics and to spread awareness. In order to tackle these problems, both groups suggested a multipronged approach including robust public awareness campaigns also involving schools, better doctor-patient relationships, and stronger regulations. Although students and teachers exhibited poor knowledge about antibiotic use and resistance, they were keen to learn about these issues. School education programs and public education could be used to shape correct perceptions about antibiotic use among all stakeholders including children. This may help in the containment of antibiotic resistance and thus preservation of antibiotics for future generations.
Proceedings: 1995 SO{sub 2} control symposium. Volume 3, Sessions 6a, 6b, 7a, 7b
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-01
Cosponsored by EPRI, DOE, and EPA, this conference provided a forum for the exchange of economic, technical, and regulatory information on sulfur dioxide control technology. From March 28--31, 1995, participants presented 100 technical papers to an audience of 525 people from around the world. Given in thirteen technical sessions, the papers included regulatory and economic issues, wet and dry SO{sub 2} control processes, emerging technologies, and experience with Clean Air Act Amendments (CAAA) Phase I startups. The fifteenth in a series of symposia over the past two decades, the conference included these key points: the domestic flue gas desulfurization (FGD)more » market is likely to be modest over the next ten years, with most activity overseas; FGD awards could reach over $4 billion a year from 1996--2003, with more than half going to Eastern Europe and Asia; worldwide, at the start of 1994, FGD systems were installed on 609 coal-fired power plants; the average capital cost for Phase I retrofits has been $233/kW; and, trends point to simpler designs, such as towers that operate at higher gas velocities with fewer internals. Published proceedings from these regularly scheduled symposia are valuable resources for engineers and utility planners who need up-to-date information to comply with clean air legislation. Selected papers have been processed separately for inclusion in the Energy Science and Technology database.« less
Proceedings: 1995 SO{sub 2} control symposium. Volume 2, Sessions 4a, 4b, 5a, 5b
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-06-01
Cosponsored by EPRI, DOE, and EPA, this conference provided a forum for the exchange of economic, technical, and regulatory information on sulfur dioxide control technology. From March 28--31, 1995, participants presented 100 technical papers to an audience of 525 people from around the world. Given in thirteen technical sessions, the papers included regulatory and economic issues, wet and dry SO{sub 2} control processes, emerging technologies, and experience with Clean Air Act Amendments (CAAA) Phase I startups. The fifteenth in a series of symposia over the past two decades, the conference included these key points: the domestic flue gas desulfurization (FGD)more » market is likely to be modest over the next ten years, with most activity overseas; FGD awards could reach over $4 billion a year from 1996--2003, with more than half going to Eastern Europe and Asia; worldwide, at the start of 1994, FGD systems were installed on 609 coal-fired power plants; the average capital cost for Phase I retrofits has been $233/kW; and, trends point to simpler designs, such as towers that operate at higher gas velocities with fewer internals. Published proceedings from these regularly scheduled symposia are valuable resources for engineers and utility planners who need up-to-date information to comply with clean air legislation. Selected papers have been processed separately for inclusion in the Energy Science and Technology database.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bashiri, G.; Squire, C.J.; Moreland, N.J.
2009-05-11
The modified flavin coenzyme F{sub 420} is found in a restricted number of microorganisms. It is widely distributed in mycobacteria, however, where it is important in energy metabolism, and in Mycobacterium tuberculosis (Mtb) is implicated in redox processes related to non-replicating persistence. In Mtb, the F{sub 420}-dependent glucose-6-phosphate dehydrogenase FGD1 provides reduced F{sub 420} for the in vivo activation of the nitroimidazopyran prodrug PA-824, currently being developed for anti-tuberculosis therapy against both replicating and persistent bacteria. The structure of M. tuberculosis FGD1 has been determined by x-ray crystallography both in its apo state and in complex with F{sub 420} andmore » citrate at resolutions of 1.90 and 1.95{angstrom}, respectively. The structure reveals a highly specific F{sub 420} binding mode, which is shared with several other F{sub 420}-dependent enzymes. Citrate occupies the substrate binding pocket adjacent to F{sub 420} and is shown to be a competitive inhibitor (IC{sub 50} 43 {micro}m). Modeling of the binding of the glucose 6-phosphate (G6P) substrate identifies a positively charged phosphate binding pocket and shows that G6P, like citrate, packs against the isoalloxazine moiety of F{sub 420} and helps promote a butterfly bend conformation that facilitates F{sub 420} reduction and catalysis.« less
You, Changfu; Li, Yuan
2013-03-19
Semidry flue gas desulfurization (FGD) experiments were conducted using rapidly hydrated sorbents with four different adhesive carrier particles: circulation ash from a circulating fluidized bed boiler (CFBB circulation ash), fly ash from the first electrical field of the electrostatic precipitator of a circulating fluidized bed boiler (CFBB ESP ash), fly ash from a chain boiler (chain boiler ash), and river sand smaller than 1 mm. The influences of various adhesive carrier particles and operating conditions on the desulfurization characteristics of the sorbents were investigated, including sprayed water, reaction temperature, and the ratio of calcium to sulfur (Ca/S). The experimental results indicated that the rapidly hydrated sorbents had better desulfurization characteristics by using adhesive carrier particles which possessed better pore, adhesion, and fluidization characteristics. The desulfurization efficiency of the system increased as the reaction temperature decreased, it improved from 35% to 90% as the mass flow rate of the sprayed water increased from 0 to 10 kg/h, and it increased from 65.6% to 82.7% as Ca/S increased from 1.0 to 2.0. Based on these findings, a new semidry circulating fluidized bed (CFB)-FGD system using rapidly hydrated sorbent was developed. Using the rapidly hydrated sorbent, this system uses a cyclone separator instead of an ESP or a bag filter to recycle the sorbent particles, thereby decreasing the system flow resistance, saving investment and operating costs of the solids collection equipment.
Mineralogical Associations of Mercury in FGD Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beatty, William Lee; Schroeder, Karl; Beatty, Candace L. Kairies
2012-06-21
The natural mode of retention of mercury in flue gas desulfurization gypsum used in wallboard manufacturing has been investigated using a series of phase-targeted reagents. Results indicate that mercury was associated with two distinct phases.
Lin, Hung-Ju; Hsieh, Kun-Pin; Chiou, Shyh-Shin; Kou, Hwang-Shang; Wu, Shou-Mei
2016-11-30
A field-amplified sample stacking-sweeping micellar electrokinetic chromatography with short-end injection was established for determination of deferasirox (DFX) in plasma. DFX was extracted from plasma and reconstituted with deionized water (lower conductivity solution). Capillary (effective length, 10cm) was filled with background electrolyte (40mM phosphate buffer, pH 4.5, containing 20% methanol). After sample loading from outlet end at 5psi for 15s, separation was carried out by applying high voltage at 15kV for 10min. Sodium dodecyl sulfate (SDS) was used to sweep DFX for enhancing sensitivity. The optimal CE separation conditions were 40mM phosphate buffer at pH 4.5 containing 100mM SDS and 20% methanol. The analysis time was about 3.5min for DFX. The calibration curve of DFX was ranged from 1 to 20μg/ml. The linearity (r) was more than 0.998. RSD and RE in intra- and inter-day assays were all below 12.14%. The limit of detection (LOD, S/N=3) for DFX was 0.3μg/ml. The sensitivity enhancement factor between sweeping-FASS MEKC and capillary zone electrophoresis is 3.3. Finally, the method was applied for determination of DFX in β-thalassemia patients. Copyright © 2016 Elsevier B.V. All rights reserved.
Kivihiilivoimalan Sivutuotteiden Maarakennuskaeytoen Elinkaariarviointi
DOT National Transportation Integrated Search
1998-01-01
The goal of this project was to assess the environmental impact of using fly ash and flue gas desulphurization (FGD) residues (produced by pulverized coal-fired power plants which employ semi dry scrubbing technology) in earthworks. The use of fly as...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richmann, D.L.; Rossi, J.P.; Rashin, E.B.
1984-07-01
The major objective of this project is to provide electric utilities with information concerning the availability of flue gas desulfurization (FGD) system reagents. Data presented in this report were obtained primarily from a comprehensive review of available literature. These were augmented by information gathered through interviews with knowledgeable individuals from industry, government, and academic institutions. Limestone data are presented on regional and state maps displaying, respectively, annual limestone production and number of active quarries by county; and areas most likely to contain potentially commercial deposits of high-Ca (greater than or equal to 90% CaCO/sub 3/) limestone. Lime data are presentedmore » on regional maps indicating ranges of annual production and number of active lime plants by county. Identification of commercial versus captive operations and estimates of lime availability on the open market are summarized in tables accompanying each map.« less
Ore sintering flue gas desulfurization and its resoureilization by using pyrolusite
NASA Astrophysics Data System (ADS)
Li, S. E.; Long, Z. G.; Wu, F. Z.; Li, H. Y.; Cui, T. M.; Zhou, X. Z.
2017-11-01
Flue gas desulfurization (FGD) has been implemented for sulfur dioxide gas emission reduction by pyrolusite in iron ore sintering. However, the mechanism of SO2 reduction through FGD is still not fully clear. And in present work, the effects of operating conditions on desulfurization rate and Mn2+ leaching rate of pyrolusite were investigated. Six hours later, the desulfurization rate and Mn2+ leaching rate all can be higher than 70%. And a higher absorption temperature was good for desulfurization rate, while a middle temperature was good for Mn2+ leaching rate. A higher manganese ore granularity and SO2 concentration were good for desulfurization rate and Mn2+ leaching rate. However, a higher liquid-solid rate was only good for desulfurization rate, but Mn2+ leaching rate. The results demonstrate that the pyrolusite is a kind of very promising adsorbent in industrial flue gas desulfurization application due to its low cost and good desulfurization capacity.
NASA Astrophysics Data System (ADS)
Gong, Jianying; Zhang, Xingwang; Wang, Xiaoping; Lei, Lecheng
2013-12-01
Oxidation of S(IV) to S(VI) in the effluent of a flue gas desulfurization(FGD) system is very critical for industrial applications of seawater FGD. This paper reports a pulsed corona discharge oxidation process combined with a TiO2 photocatalyst to convert S(IV) to S(VI) in artificial seawater. Experimental results show that the oxidation of S(IV) in artificial seawater is enhanced in the pulsed discharge plasma process through the application of TiO2 coating electrodes. The oxidation rate of S(IV) using Ti metal as a ground electrode is about 2.0×10-4 mol · L-1 · min-1, the oxidation rate using TiO2/Ti electrode prepared by annealing at 500°C in air is 4.5×10-4 mol · L-1 · min-1, an increase with a factor 2.25. The annealing temperature for preparing TiO2/Ti electrode has a strong effect on the oxidation of S(IV) in artificial seawater. The results of in-situ emission spectroscopic analysis show that chemically active species (i.e. hydroxyl radicals and oxygen radicals) are produced in the pulsed discharge plasma process. Compared with the traditional air oxidation process and the sole plasma-induced oxidation process, the combined application of TiO2 photocatalysts and a pulsed high-voltage electrical discharge process is useful in enhancing the energy and conversion efficiency of S(IV) for the seawater FGD system.
Masilela, E; Lerotholi, L; Seodigeng, T; Rutto, H
2018-02-01
The disposal of industrial brine sludge waste (IBSW) in chlor-alkali plants can be avoided by utilization of IBSW as a sorbent in wet flue gas desulfurization (FGD). The shrinking core model was used to determine the dissolution kinetics of IBSW, which is a vital step in wet FGD. The effects of solid-to-liquid ratio (m/v), temperature, pH, particle size, and stirring speed on the conversion and dissolution rate constant are determined. The conversion and dissolution rate constant decreases as the pH, particle size, and solid-to-liquid ratio are increased and increases as the temperature, concentration of acid, and stirring speed are increased. The sorbents before and after dissolution were characterized using x-ray fluorescence (XRF), x-ray diffraction (XRD), and scanning electron microscopy (SEM). An activation energy of 7.195 kJ/mol was obtained and the product layer diffusion model was found to be the rate-controlling step. The use of industrial brine sludge waste as an alternative sorbent in wet flue gas desulfurization can reduce the amounts of industrial wastes disposed of in landfills. This study has proved that the sorbent can contain up to 91% calcium carbonate and trace amounts of sulfate, magnesium, and so on. This can be used as new sorbent to reduce the amount of sulfur dioxide in the atmosphere and the by-product gypsum can be used in construction, as a plaster ingredient, as a fertilizer, and for soil conditioning. Therefore, the sorbent has both economic and environmental benefits.
Testing Mechanisms of Mercury Retention in GFD Products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beatty, W.L.; Schroeder, K.T.; Kairies, C.L.
2007-07-01
The natural mode of retention of Hg in FGD products is a key issue in the utilization of coal byproducts as environmentally acceptable resources. This is being investigated with a sequential extraction scheme that subjects FGD material to a series of phase-targeted reagents. Mineral phases with the greatest affinity for Hg and the form in which Hg is naturally immobilized can be discovered by observing the amount of Hg mobilized by each successive extracting solution. The extraction procedure consists of a prolonged water rinse in a continuously stirred tank extractor to dissolve CaSO4 followed by a series of batch extractions.more » These extraction include: a water rinse of the resulting residue to remove any remaining water soluble and loosely sorbed ions, 0.11M acetic acid to target carbonate minerals and exchangeable ions, 0.1 M hydroxylamine hydrochloride to dissolve manganese oxides and hydroxides, 0.25 M hydroxylamine hydrochloride in 0.25 M HCl to dissolve iron oxides and hydroxides, and hydrogen peroxide and 0.1 M ammonium acetate to oxidize organic matter and dissolve sulfide minerals. Analysis of the supernatant after each extraction step includes ICP-OES or ICP-MS for major and trace elemental composition and CVAF for mercury. Initial results indicate that Hg is associated with two distinct fractions of FGD materials. Although most of the solubilized Hg is extracted by the iron oxide and hydroxide dissolution reagent, ICP analysis suggests an association with clay minerals present in this fraction. The organic matter and sulfide minerals fraction typically yields lower but still significant amounts of Hg.« less
Safety considerations in testing a fuel-rich aeropropulsion gas generator
NASA Technical Reports Server (NTRS)
Rollbuhler, R. James; Hulligan, David D.
1991-01-01
A catalyst containing reactor is being tested using a fuel-rich mixture of Jet A fuel and hot input air. The reactor product is a gaseous fuel that can be utilized in aeropropulsion gas turbine engines. Because the catalyst material is susceptible to damage from high temperature conditions, fuel-rich operating conditions are attained by introducing the fuel first into an inert gas stream in the reactor and then displacing the inert gas with reaction air. Once a desired fuel-to-air ratio is attained, only limited time is allowed for a catalyst induced reaction to occur; otherwise the inert gas is substituted for the air and the fuel flow is terminated. Because there presently is not a gas turbine combustor in which to burn the reactor product gas, the gas is combusted at the outlet of the test facility flare stack. This technique in operations has worked successfully in over 200 tests.
Non-planar microfabricated gas chromatography column
Lewis, Patrick R.; Wheeler, David R.
2007-09-25
A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.
Thin planar package for cooling an array of edge-emitting laser diodes
Mundinger, David C.; Benett, William J.
1992-01-01
A laser diode array is disclosed that includes a plurality of planar assemblies and active cooling of each assembly. The laser diode array may be operated in a long duty cycle, or in continuous operation. A laser diode bar and a microchannel heat sink are thermally coupled in a compact, thin planar assembly having the laser diode bar located proximate to one edge. In an array, a number of such thin planar assemblies are secured together in a stacked configuration, in close proximity so that the laser diodes are spaced closely. The cooling means includes a microchannel heat sink proximate to the laser diode bar to absorb heat generated by laser operation. To provide the coolant to the microchannels, each thin planar assembly comprises passageways that connect the microchannels to inlet and outlet corridors. Each inlet passageway may comprise a narrow slot that directs coolant into the microchannels and increases the velocity of flow therethrough. The corridors comprises holes extending through each of the assemblies in the array. The inlet and outlet corridors are connected to a conventional coolant circulation system. The laser diode array with active cooling has applications as an optical pump for high power solid state lasers, or by mating the diodes with fiber optic lenses. Further, the arrays can be useful in applications having space constraints and energy limitations, and in military and space applications. The arrays can be incorporated in equipment such as communications devices and active sensors.
Bonora, Gianluca; Mancini, Martina; Carpinella, Ilaria; Chiari, Lorenzo; Ferrarin, Maurizio; Nutt, John G.; Horak, Fay B.
2017-01-01
The One-Leg Stance (OLS) test is a widely adopted tool for the clinical assessment of balance in the elderly and in subjects with neurological disorders. It was previously showed that the ability to control anticipatory postural adjustments (APAs) prior to lifting one leg is significantly impaired by idiopathic Parkinson’s disease (iPD). However, it is not known how APAs are affected by other types of parkinsonism, such as frontal gait disorders (FGD). In this study, an instrumented OLS test based on wearable inertial sensors is proposed to investigate both the initial anticipatory phase and the subsequent unipedal balance. The sensitivity and the validity of the test have been evaluated. Twenty-five subjects with iPD presenting freezing of gait (FOG), 33 with iPD without FOG, 13 with FGD, and 32 healthy elderly controls were recruited. All subjects wore three inertial sensors positioned on the posterior trunk (L4–L5), and on the left and right frontal face of the tibias. Participants were asked to lift a foot and stand on a single leg as long as possible with eyes open, as proposed by the mini-BESTest. Temporal parameters and trunk acceleration were extracted from sensors and compared among groups. The results showed that, regarding the anticipatory phase, the peak of mediolateral trunk acceleration was significantly reduced compared to healthy controls (p < 0.05) in subjects with iPD with and without FOG, but not in FGD group (p = 0.151). Regarding the balance phase duration, a significant shortening was found in the three parkinsonian groups compared to controls (p < 0.001). Moreover, balance was significantly longer (p < 0.001) in iPD subjects without FOG compared to subjects with FGD and iPD subjects presenting FOG. Strong correlations between balance duration extracted by sensors and clinical mini-BESTest scores were found (ρ > 0.74), demonstrating the method’s validity. Our findings support the validity of the proposed method for assessing the OLS test and its sensitivity in distinguishing among the tested groups. The instrumented test discriminated between healthy controls and people with parkinsonism and among the three groups with parkinsonism. The objective characterization of the initial anticipatory phase represents an interesting improvement compared to most clinical OLS tests. PMID:28790972
Bonora, Gianluca; Mancini, Martina; Carpinella, Ilaria; Chiari, Lorenzo; Ferrarin, Maurizio; Nutt, John G; Horak, Fay B
2017-01-01
The One-Leg Stance (OLS) test is a widely adopted tool for the clinical assessment of balance in the elderly and in subjects with neurological disorders. It was previously showed that the ability to control anticipatory postural adjustments (APAs) prior to lifting one leg is significantly impaired by idiopathic Parkinson's disease (iPD). However, it is not known how APAs are affected by other types of parkinsonism, such as frontal gait disorders (FGD). In this study, an instrumented OLS test based on wearable inertial sensors is proposed to investigate both the initial anticipatory phase and the subsequent unipedal balance. The sensitivity and the validity of the test have been evaluated. Twenty-five subjects with iPD presenting freezing of gait (FOG), 33 with iPD without FOG, 13 with FGD, and 32 healthy elderly controls were recruited. All subjects wore three inertial sensors positioned on the posterior trunk (L4-L5), and on the left and right frontal face of the tibias. Participants were asked to lift a foot and stand on a single leg as long as possible with eyes open, as proposed by the mini-BESTest. Temporal parameters and trunk acceleration were extracted from sensors and compared among groups. The results showed that, regarding the anticipatory phase, the peak of mediolateral trunk acceleration was significantly reduced compared to healthy controls ( p < 0.05) in subjects with iPD with and without FOG, but not in FGD group ( p = 0.151). Regarding the balance phase duration, a significant shortening was found in the three parkinsonian groups compared to controls ( p < 0.001). Moreover, balance was significantly longer ( p < 0.001) in iPD subjects without FOG compared to subjects with FGD and iPD subjects presenting FOG. Strong correlations between balance duration extracted by sensors and clinical mini-BESTest scores were found (ρ > 0.74), demonstrating the method's validity. Our findings support the validity of the proposed method for assessing the OLS test and its sensitivity in distinguishing among the tested groups. The instrumented test discriminated between healthy controls and people with parkinsonism and among the three groups with parkinsonism. The objective characterization of the initial anticipatory phase represents an interesting improvement compared to most clinical OLS tests.
Soluble calcium amendments: reducing pathogen losses
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization (FGD) gypsum is a byproduct of coal-fired power plants. Its application to agricultural fields may increase water infiltration, reduce soil erosion, and decrease nutrient losses from applications of animal manures. It may also reduce fecal bacterial contamination of surface ...
40 CFR 60.257 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... opacity in that portion of the plume where condensed water vapor is not present. Water vapor is not... after wet FGD systems if the effluent is saturated or laden with water droplets. (6) Method 6, 6A, or 6C...
40 CFR 60.257 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... opacity in that portion of the plume where condensed water vapor is not present. Water vapor is not... after wet FGD systems if the effluent is saturated or laden with water droplets. (6) Method 6, 6A, or 6C...
40 CFR 60.257 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... opacity in that portion of the plume where condensed water vapor is not present. Water vapor is not... after wet FGD systems if the effluent is saturated or laden with water droplets. (6) Method 6, 6A, or 6C...
40 CFR 60.257 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... opacity in that portion of the plume where condensed water vapor is not present. Water vapor is not... after wet FGD systems if the effluent is saturated or laden with water droplets. (6) Method 6, 6A, or 6C...
40 CFR 60.257 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... opacity in that portion of the plume where condensed water vapor is not present. Water vapor is not... after wet FGD systems if the effluent is saturated or laden with water droplets. (6) Method 6, 6A, or 6C...
SHAWNEE FLUE GAS DESULFURIZATION COMPUTER MODEL USERS MANUAL
The manual describes a Shawnee flue gas desulfurization (FGD) computer model and gives detailed instructions for its use. The model, jointly developed by Bechtel National, Inc. and TVA (in conjunction with the EPA-sponsored Shawnee test program), is capable of projecting prelimin...
FLUE GAS DESULFURIZATION: THE STATE OF THE ART
The paper gives results of a review of commercially available flue gas desulfurization (FGD) technologies that have an established record of full-scale performance. (NOTE: Sulfur dioxide (SO2) scrubbers may be used by coal-fired electrcity generating units to meet the requiremen...
EFFECTS OF LEACHING ON PORE SIZE DISTRIBUTION OF SOLIDIFIED/STABILIZED WASTES
Chemical solidification/stabilization processes are commonly used to immobilize metals in fly ash and flue gas desulfurization (FGD) sludges and to convert these wastes into monolithic or granular materials with better handling properties and reduced permeabilities. his study eva...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prudich, M.E.; Appell, K.W.; McKenna, J.D.
ETS, Inc., a pollution consulting firm with headquarters in Roanoke, Virginia, has developed a dry, limestone-based flue gas desulfurization (FGD) system. This SO{sub 2} removal system, called Limestone Emission Control (LEC), can be designed for installation on either new or existing coal-fired boilers. In the LEC process, the SO{sub 2} in the flue gas reacts with wetted granular limestone that is contained in a moving bed. A surface layer of principally calcium sulfate (CaSO{sub 4}) is formed on the limestone. Periodic removal of this surface layer by mechanical agitation allows high utilization of the limestone granules. A nominal 5,000 acfmmore » LEC pilot plant has been designed, fabricated and installed on the slipstream of a 70,000 pph stoker boiler providing steam to Ohio University`s Athens, Ohio campus. A total of over 90 experimental trials have been performed using the pilot-scale moving-bed LEC dry scrubber as a part of this research project with run times ranging up to a high of 125 hours. SO{sub 2} removal efficiencies as high as 99.9% were achievable for all experimental conditions studied during which sufficient humidification was added to the LEC bed. The LEC process and conventional limestone scrubbing have been compared on an equatable basis using flue gas conditions that would be expected at the outlet of the electrostatic precipitator (ESP) of a 500 MW coal-fired power plant. The LEC was found to have a definite economic advantage in both direct capital costs and operating costs. Based on the success and findings of the present project, the next step in LEC process development will be a full-scale commercial demonstration unit.« less
Gingerich, Daniel B; Sun, Xiaodi; Behrer, A Patrick; Azevedo, Inês L; Mauter, Meagan S
2017-02-21
Coal-fired power plants (CFPPs) generate air, water, and solids emissions that impose substantial human health, environmental, and climate change (HEC) damages. This work demonstrates the importance of accounting for cross-media emissions tradeoffs, plant and regional emissions factors, and spatially variation in the marginal damages of air emissions when performing regulatory impact analyses for electric power generation. As a case study, we assess the benefits and costs of treating wet flue gas desulfurization (FGD) wastewater at US CFPPs using the two best available treatment technology options specified in the 2015 Effluent Limitation Guidelines (ELGs). We perform a life-cycle inventory of electricity and chemical inputs to FGD wastewater treatment processes and quantify the marginal HEC damages of associated air emissions. We combine these spatially resolved damage estimates with Environmental Protection Agency estimates of water quality benefits, fuel-switching benefits, and regulatory compliance costs. We estimate that the ELGs will impose average net costs of $3.01 per cubic meter for chemical precipitation and biological wastewater treatment and $11.26 per cubic meter for zero-liquid discharge wastewater treatment (expected cost-benefit ratios of 1.8 and 1.7, respectively), with damages concentrated in regions containing a high fraction of coal generation or a large chemical manufacturing industry. Findings of net cost for FGD wastewater treatment are robust to uncertainty in auxiliary power source, location of chemical manufacturing, and binding air emissions limits in noncompliant regions, among other variables. Future regulatory design will minimize compliance costs and HEC tradeoffs by regulating air, water, and solids emissions simultaneously and performing regulatory assessments that account for spatial variation in emissions impacts.
Landslide remediation on Ohio State Route 83 using clean coal combustion by-products
DOE Office of Scientific and Technical Information (OSTI.GOV)
Payette, R.; Chen, X.Y.; Wolfe, W.
1995-12-31
In the present work, a flue gas desulfurization (FGD) by-product was used to reconstruct the failed portion of a highway embankment. The construction process and the stability of the repaired embankment are examined. State Route 83 in Cumberland, Ohio has been damaged by a slow moving slide which has forced the Ohio Department of Transportation to repair the roadway several times. In the most recent repair FGD by-products obtained from American Electric Power`s Tidd PFBC plant were used to construct a wall through the failure plane to prevent further slippage. In order to evaluate the utility of using coal combustionmore » by-products in this type of highway project the site was divided into three test sections. In the first repair section, natural soil removed form the slide area was recompacted and replaced according to standard ODOT construction practices. In the second section the natural soil was field mixed with the Tidd PFBC ash in approximately equal proportions. The third section was all Tidd ash. The three test sections were capped by a layer of compacted Tidd ash or crushed stone to provide a wearing surface to allow ODOT to open the roadway before applying a permanent asphalt surface. Measurement of slope movement as well as water levels and quality have begun at the site in order to evaluate long term project performance. The completion of this project should lead to increased acceptance of FGD materials in construction projects. Monetary savings will be realized in avoiding some of the disposal costs for the waste, as well as in the reduced reliance on alternative engineering materials.« less
Wood, Molly E; Mansoor, G Farooq; Hashemy, Pashton; Namey, Emily; Gohar, Fatima; Ayoubi, Saadia Fayeq; Todd, Catherine S
2013-10-01
to examine factors that affect retention of public sector midwives throughout their career in Afghanistan. qualitative assessment using semi-structured in-depth interviews (IDIs) and focus group discussions (FGDs). health clinics in eight provinces in Afghanistan, midwifery education schools in three provinces, and stakeholder organisations in Kabul. purposively sampled midwifery profession stakeholders in Kabul (n=14 IDIs); purposively selected community midwifery students in Kabul (n=3 FGDs), Parwan (n=1 FGD) and Wardak (n=1 FGD) provinces (six participants per FGD); public sector midwives, health facility managers, and community health workers from randomly selected clinics in eight provinces (n=48 IDIs); midwives who had left the public sector midwifery service (n=5 IDIs). several factors affect a midwife throughout her career in the public sector, including her selection as a trainee, the training itself, deployment to her pre-assigned post, and working in clinics. Overall, appropriate selection is the key to ensuring deployment and retention later on in a midwife's career. Other factors that affect retention of midwives include civil security concerns in rural areas, support of family and community, salary levels, professional development opportunities and workplace support, and inefficient human resources planning in the public sector. Factors affecting midwife retention are linked to problems within the community midwifery education (CME) programme and those reflecting the wider Afghan context. Civil insecurity and traditional attitudes towards women were major factors identified that negatively affect midwifery retention. Factors such as civil insecurity and traditional attitudes towards women require a multisectoral response and innovative strategies to reduce their impact. However, factors inherent to midwife career development also impact retention and may be more readily modified. © 2013 Elsevier Ltd. All rights reserved.
Gingerich, Daniel B.; Behrer, A. Patrick; Azevedo, Inês L.
2017-01-01
Coal-fired power plants (CFPPs) generate air, water, and solids emissions that impose substantial human health, environmental, and climate change (HEC) damages. This work demonstrates the importance of accounting for cross-media emissions tradeoffs, plant and regional emissions factors, and spatially variation in the marginal damages of air emissions when performing regulatory impact analyses for electric power generation. As a case study, we assess the benefits and costs of treating wet flue gas desulfurization (FGD) wastewater at US CFPPs using the two best available treatment technology options specified in the 2015 Effluent Limitation Guidelines (ELGs). We perform a life-cycle inventory of electricity and chemical inputs to FGD wastewater treatment processes and quantify the marginal HEC damages of associated air emissions. We combine these spatially resolved damage estimates with Environmental Protection Agency estimates of water quality benefits, fuel-switching benefits, and regulatory compliance costs. We estimate that the ELGs will impose average net costs of $3.01 per cubic meter for chemical precipitation and biological wastewater treatment and $11.26 per cubic meter for zero-liquid discharge wastewater treatment (expected cost-benefit ratios of 1.8 and 1.7, respectively), with damages concentrated in regions containing a high fraction of coal generation or a large chemical manufacturing industry. Findings of net cost for FGD wastewater treatment are robust to uncertainty in auxiliary power source, location of chemical manufacturing, and binding air emissions limits in noncompliant regions, among other variables. Future regulatory design will minimize compliance costs and HEC tradeoffs by regulating air, water, and solids emissions simultaneously and performing regulatory assessments that account for spatial variation in emissions impacts. PMID:28167772
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, R.L.
A literature survey was conducted in order to determine the amount of information available to the public concerning the impact of the Resource Conservation and Recovery Act of 1976 (RCRA) on the use or disposal of solid wastes from Texas lignite-fired utility boilers. The utility power plants of ALCOA, Big Brown, Martin Lake, Monticello and San Miguel are the only facilities currently using Texas lignite as fuel. RCRA is a comprehensive federal law which provides for the management of hazardous waste from generation to ultimate disposal. Utility solid wastes such as fly ash and flue gas desulfurization (FGD) sludge aremore » currently classified as excluded wastes (wastes exempt from hazardous classification) pending further information regarding these high-volume, low risk wastes. RCRA also provides for the increased need of recovered materials in Subtitle F - Federal Procurement. The lignite deposits of Texas occur in belts that stretch diagonally across the state from Laredo to Texarkana. The sulfur content and Btu value of Texas lignite combined requires that sulfur scrubbers be installed on new power plant units. The utility solid wastes occur in large quantities and leachate from some of these wastes contained detectable amounts of chromium and selenium. However, the concentration of these elements in the leachate was not sufficient to classify any of the utility wastes in this study as hazardous per current RCRA guidelines. In general, fly ash and FGD sludge are classified as Class II wastes and disposed of in an environmentally acceptable manner. Considerable amounts of bottom ash and fly ash are utilized but, thus far, FGD sludge has been landfilled, usually in combination with fly ash.« less
Leaching of FGD Byproducts Using a CSTX
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kairies, C.L.; Schroeder, K.T.; Cardone, C.R.
2005-09-01
Leaching studies of coal utilization byproducts (CUB) are often performed to determine the compatibility of the material in a particular end-use or disposal environment. Typically, these studies are conducted using either a batch or a fixed-bed column technique. Fixed-bed columns offer the advantage of a continuous flow of effluent that provides elution profiles with changing elution volume and pH. Unfortunately, clogs can form in fixed-bed leaching columns, either because of cementitious properties of the material itself, such as is seen for fluidized bed combustion (FBC) fly ash, or because of precipitate formation, such as can occur when a high-calcium ashmore » is subjected to sulfate-containing leachates. Also, very fine-grained materials, such as gypsum, do not provide sufficient permeability for study in a fixed-bed column. A continuous, stirred-tank extractor (CSTX) is being used as an alternative technique that can provide the elution profile of column leaching but without the low permeability problems. The CSTX has been successfully employed in the leaching of flue gas desulfurization products that would not be sufficiently permeable under traditional column leaching conditions. The results indicate that the leaching behavior depends on a number of factors, including (but not limited to) solubility and neutralization capacity of the mineral phases present, sorption properties of these phases, behavior of the solubilized material in the tank, and the type of species in solution. In addition, leaching to near-exhaustion of a wallboard produced from FGD gypsum has allowed the isolation of a highly adsorptive phase. This phase appears to be present in at least some FGD gypsums and accounts for the immobilization of trace metals such as arsenic, cobalt, lead, and mercury.« less
Feuerriegel, Silke; Köser, Claudio U.; Baù, Davide; Rüsch-Gerdes, Sabine; Summers, David K.; Archer, John A. C.; Marti-Renom, Marc A.; Niemann, Stefan
2011-01-01
PA-824 is a promising drug candidate for the treatment of tuberculosis (TB). It is in phase II clinical trials as part of the first newly designed regimen containing multiple novel antituberculosis drugs (PA-824 in combination with moxifloxacin and pyrazinamide). However, given that the genes involved in resistance against PA-824 are not fully conserved in the Mycobacterium tuberculosis complex (MTBC), this regimen might not be equally effective against different MTBC genotypes. To investigate this question, we sequenced two PA-824 resistance genes (fgd1 [Rv0407] and ddn [Rv3547]) in 65 MTBC strains representing major phylogenetic lineages. The MICs of representative strains were determined using the modified proportion method in the Bactec MGIT 960 system. Our analysis revealed single-nucleotide polymorphisms in both genes that were specific either for several genotypes or for individual strains, yet none of these mutations significantly affected the PA-824 MICs (≤0.25 μg/ml). These results were supported by in silico modeling of the mutations identified in Fgd1. In contrast, “Mycobacterium canettii” strains displayed a higher MIC of 8 μg/ml. In conclusion, we found a large genetic diversity in PA-824 resistance genes that did not lead to elevated PA-824 MICs. In contrast, M. canettii strains had MICs that were above the plasma concentrations of PA-824 documented so far in clinical trials. As M. canettii is also intrinsically resistant against pyrazinamide, new regimens containing PA-824 and pyrazinamide might not be effective in treating M. canettii infections. This finding has implications for the design of multiple ongoing clinical trials. PMID:21930879
The Turbo-Fuel-Cell 1.0 - family concept
NASA Astrophysics Data System (ADS)
Berg, H. P.; Himmelberg, A.; Lehmann, M.; Dückershoff, R.; Neumann, M.
2018-01-01
The “Turbo-Fuel-Cell-Technology” has been described as a MGT-SOFC hybrid system consisting of a recuperated micro gas turbine (MGT) process with an embedded solid oxide fuel cell (SOFC) subsystem. SOFC stacks are connected to “SOFC stack grapes” and are equipped with the so called HEXAR-Module. This module is composed of a high-temperature heat exchanger (HEX), an afterburner (A) and a steam reformer (R). The MGT-concept is based on a generator driven directly by the turbomachine and a recuperator, which returns the exhaust heat to the pressurized compressor outlet air. This provides the necessary base for a highly effective, pure MGT process and the “MGT-SOFC-high-efficiency process”. This paper describes the concept and the thermodynamic background of a highly effective and compact design of the “Turbo-Fuel-Cell 1.0-Family” in the electrical performance class from 100 to 500 kW. The technological state of the system is shown and a rating of the system with comparative parameters is discussed. It becomes visible that all necessary basic technologies should be available and that the technology (for stationary applications) can have the “entry into services (E.I.S.)” in the next 10 years. The MGT-SOFC performance map under different operation conditions is discussed. This article also provides an overview of the research on MGT-SOFC-Systems and the scenario of an energy supply network and a mobile energy conversion of the future introduction.
Zhu, Weibin; Park, Jong M.; White, Michael J.; Nellis, Gregory F.; Gianchandani, Yogesh B.
2011-01-01
This article reports the evaluation of a Joule–Thomson (JT) cooling system that combines two custom micromachined components—a Si/glass-stack recuperative heat exchanger and a piezoelectrically actuated expansion microvalve. With the microvalve controlling the flow rate, this system can modulate cooling to accommodate varying refrigeration loads. The perforated plate Si/glass heat exchanger is fabricated with a stack of alternating silicon plates and Pyrex glass spacers. The microvalve utilizes a lead zirconate titanate actuator to push a Si micromachined valve seat against a glass plate, thus modulating the flow passing through the gap between the valve seat and the glass plate. The fabricated heat exchanger has a footprint of 1×1 cm2 and a length of 35 mm. The size of the micromachined piezoelectrically actuated valve is about 1×1×1 cm3. In JT cooling tests, the temperature of the system was successfully controlled by adjusting the input voltage of the microvalve. When the valve was fully opened (at an input voltage of −30 V), the system cooled down to a temperature as low as 254.5 K at 430 kPa pressure difference between inlet and outlet at steady state and 234 K at 710 kPa in a transient state. The system provided cooling powers of 75 mW at 255 K and 150 mW at 258 K. Parasitic heat loads at 255 K are estimated at approximately 700 mW. PMID:21552354
Lowenstein, Andrew; Sibilia, Marc; Miller, Jeffrey; Tonon, Thomas S.
2004-06-08
A heat exchange assembly comprises a plurality of plates disposed in a spaced-apart arrangement, each of the plurality of plates includes a plurality of passages extending internally from a first end to a second end for directing flow of a heat transfer fluid in a first plane, a plurality of first end-piece members equaling the number of plates and a plurality of second end-piece members also equaling the number of plates, each of the first and second end-piece members including a recessed region adapted to fluidly connect and couple with the first and second ends of the plate, respectively, and further adapted to be affixed to respective adjacent first and second end-piece members in a stacked formation, and each of the first and second end-piece members further including at least one cavity for enabling entry of the heat transfer fluid into the plate, exit of the heat transfer fluid from the plate, or 180.degree. turning of the fluid within the plate to create a serpentine-like fluid flow path between points of entry and exit of the fluid, and at least two fluid conduits extending through the stacked plurality of first and second end-piece members for providing first fluid connections between the parallel fluid entry points of adjacent plates and a fluid supply inlet, and second fluid connections between the parallel fluid exit points of adjacent plates and a fluid discharge outlet so that the heat transfer fluid travels in parallel paths through each respective plate.
Lowenstein, Andrew; Sibilia, Marc; Miller, Jeffrey; Tonon, Thomas S.
2003-05-27
A heat exchange assembly comprises a plurality of plates disposed in a spaced-apart arrangement, each of the plurality of plates includes a plurality of passages extending internally from a first end to a second end for directing flow of a heat transfer fluid in a first plane, a plurality of first end-piece members equaling the number of plates and a plurality of second end-piece members also equaling the number of plates, each of the first and second end-piece members including a recessed region adapted to fluidly connect and couple with the first and second ends of the plate, respectively, and further adapted to be affixed to respective adjacent first and second end-piece members in a stacked formation, and each of the first and second end-piece members further including at least one cavity for enabling entry of the heat transfer fluid into the plate, exit of the heat transfer fluid from the plate, or 180.degree. turning of the fluid within the plate to create a serpentine-like fluid flow path between points of entry and exit of the fluid, and at least two fluid conduits extending through the stacked plurality of first and second end-piece members for providing first fluid connections between the parallel fluid entry points of adjacent plates and a fluid supply inlet, and second fluid connections between the parallel fluid exit points of adjacent plates and a fluid discharge outlet so that the heat transfer fluid travels in parallel paths through each respective plate.
Characteristics of dioxin emissions at startup and shutdown of MSW incinerators.
Tejima, Hajime; Nishigaki, Masahide; Fujita, Yasuyuki; Matsumoto, Akihiro; Takeda, Nobuo; Takaoka, Masaki
2007-01-01
Dioxin concentrations from municipal waste incinerators in Japan and elsewhere often show low concentrations that comply with legal limits (in this paper, the term "dioxin" designates WHO-TEQ: PCDD/Fs+dioxin-like PCB). However, such data is usually generated under normal steady state operational conditions, and there has been little investigation of releases occurring during startup and shutdown. It is important, therefore, to ascertain quantitatively emissions in an unsteady state (startup and shutdown) in order to correctly evaluate the relationship between emissions from a facility and the surrounding environment. The present study aimed to examine dioxin emissions of a continuously operated incinerator at startup and shutdown, and estimating the time period of greatest emission, and the processes causing dioxin generation. The startup process was divided into five stages and the shutdown into two; at each stage, dioxins in the flue gas were measured at the boiler outlet and the stack. From the concentration of dioxins and the flue gas volume at each stage, the amount of dioxins at startup and shutdown were calculated, and these were compared with that under steady state conditions. Dioxin concentration at the stack under steady state conditions was a very low level, while those at startup and shutdown were higher. In the case where dioxin concentration under a steady state is a low level like in this study, it is indicated that the total annual dioxin emission from a facility could be attributed to the startup periods.
COMPUTERIZED SHAWNEE LIME/LIMESTONE SCRUBBING MODEL USERS MANUAL
The manual gives a general description of a computerized model for estimating design and cost of lime or limestone scrubber systems for flue gas desulfurization (FGD). It supplements PB80-123037 by extending the number of scrubber options which can be evaluated. It includes spray...
DISPOSAL OF BY-PRODUCTS FROM NONREGENERABLE FLUE GAS DESULFURIZATION SYSTEMS
The report gives results of a 4-year study to determine environmentally sound methods for disposing of wastes from nonregenerable flue gas desulfurization (FGD) systems. Data presented incorporates results obtained during the fourth year with material from report EPA-600/7-77-052...
COMPUTERIZED FGD BYPRODUCT PRODUCTION AND MARKETING SYSTEM: USERS MANUAL
The users manual describes a computerized system--consisting of a number of integrated programs, models, and data bases--that has been developed to compare the costs of power plant strategies designed to meet clean air regulations. It describes the data bases, programs, and proce...
ENGINEERING APPLICATION AND ECONOMICS OF LIMB (LIMESTONE INJECTION/MULTISTAGE BURNERS)
The paper describes the use of an EPA LIMB cost model, in conjunction with cost and performance models for flue gas desulfurization (FGD), to compare these two technologies under similar premises. (NOTE: The performance goals of LIMB, EPA's acronym for Limestone Injection/Multist...
MARKETING OF BYPRODUCT GYPSUM FROM FLUE GAS DESULFURIZATION
The report gives results of an evaluation of the 1985 marketing potential of byproduct gypsum from utility flue gas desulfurization (FGD), for the area east of the Rocky Mountains, using the calculated gypsum production rates of 14 selected power plants. The 114 cement plants and...
Impact of FGD gypsum application on trace elements
USDA-ARS?s Scientific Manuscript database
There are concerns regarding the fate of nutrients from surface application of animal waste. One approach to reduce losses of P is to treat manure with the industrial byproducts flue gas desulfurization gypsum (FGDG). However, concerns regarding heavy metal contributions to the environment have ar...
SOXAL{trademark} pilot plant demonstration at Niagara Mohawk`s Dunkirk Station
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strangway, P.K.
The Clean Air Act Amendments of 1990 made it necessary to accelerate the development of scrubber systems for use by some utilities burning sulfur-containing fuels, primarily coal. While many types of Flue Gas Desulfurization (FGD) systems operate based on lime and limestone scrubbing, these systems have drawbacks when considered for incorporation into long-term emissions control plans. Although the costs associated with disposal of large amounts of scrubber sludge may be manageable today, the trend is toward increased disposal costs. Many new SO{sub 2} control technologies are being pursued in the hope of developing an economical regenerable FGD system did recoversmore » the SO{sub 2} as a saleable commercial product, thus minimizing the formation of disposal waste. Some new technologies include the use of exotic chemical absorbents which are alien to the utility industry and utilities` waste treatment facilities. These systems present utilities with new environmental issues. The SOXAL{trademark} process has been developed so as to eliminate such issues.« less
Factors influencing gypsum crystal morphology within a flue gas desulfurization vessel
NASA Astrophysics Data System (ADS)
Lewis, Kinsey M.
Flue gas desulfurization (FGD) is utilized by the coal--powered generating industry to safely eliminate sulfur dioxide. A FGD vessel (scrubber) synthetically creates gypsum crystals by combining limestone (CaCO3), SO2 flue gas, water and oxygen resulting in crystalline gypsum (CaSO4 · 2H2O), which can be sold for an economic return. Flat disk--like crystals, opposed to rod--like crystals, are hard to dewater, lowering economic return. The objectives were to investigate the cause of varying morphologies, understand the environment of precipitation, as well as identify correlations between operating conditions and resulting unfavorable gypsum crystal growth. Results show evidence supporting airborne impurities due to the onsite coal pile, the abundance and size of CaCO 3 and high Ca:SO4 ratios within the scrubber as possible factors controlling gypsum crystal morphology. In conclusion, regularly purging the system and incorporating a filter on the air intake valve will provide an economic byproduct avoiding costly landfill deposits.
Altmetric: Top 50 dental articles in 2014.
Kolahi, J; Khazaei, S
2016-06-10
Introduction Altmetrics is a new and emerging scholarly tool that measures online attention surrounding journal articles. Altmetric data resources include: policy documents, news outlets, blogs, online reference managers (eg Mendeley and CiteULike), post-publication peer-review forums (eg PubPeer and Publons), social media (eg Twitter, Facebook, Weibo, Google(+), Pinterest, Reddit), Wikipedia, sites running Stack Exchange (Q&A), and reviews on F1000 and YouTube.Methods To identify the top 50 dental articles in 2014, PubMed was searched using the following query "("2014/1/1"[PDAT]:"2014/12/31"[PDAT]) and jsubsetd[text]" in December, 2015. Consequently, all PubMed records were extracted and sent to Altmetric LLP (London, UK) as a CSV file for examination. Data were analysed by Microsoft Office Excel 2010 using descriptive statistics and charts.Results Using PubMed searches,15,132 dental articles were found in 2014. The mean Altmetric score of 50 top dental articles in 2014 was 69.5 ± 73.3 (95% CI: -74.14 to 213.14). The British Dental Journal (48%) and Journal of Dental Research (16%) had the maximum number of top articles. Twitter (67.13%), Mendeley (15.89%) and news outlets (10.92%) were the most popular altmetric data resources.Discussion Altmetrics are intended to supplement bibliometrics, not replace them. Altmetrics is a fresh and emerging arena for the dental research community. We believe that dental clinical practitioners, research scientists, research directors and journal editors must pay more attention to altmetrics as a new and rapid tool to measure the social impact of scholarly articles.
SORPTION OF ELEMENTAL MERCURY BY ACTIVATED CARBONS
The mechanisms and rate of elemental mercury (HgO) capture by activated carbons have been studied using a bench-scale apparatus. Three types of activated carbons, two of which are thermally activated (PC-100 and FGD) and one with elemental sulfur (S) impregnated in it (HGR), were...
NOVEL OXIDANT FOR ELEMENTAL MERCURY CONTROL FROM FLUE GAS
A novel economical oxidant has been developed for elemental mercury (Hg(0)) removal from coal-fired boilers. The oxidant was rigorously tested in a lab-scale fixed-bed system with the Norit America's FGD activated carbon (DOE's benchmark sorbent) in a typical PRB subbituminous/l...
The report gives results of research to investigate prospects for increasing the size of calcium sulfite sludge particles in flue gas desulfurization systems. The approach included four work packages: a literature survey and development of a mathematical basis for predicting calc...
ASSESSING SPECIATION AND RELEASE OF HEAVY METALS FROM COAL COMBUSTION PRODUCTS
In this study, the speciation of heavy metals such as arsenic, selenium, lead, zinc and mercury in coal combustion products (CCPs) was evaluated using sequential extraction procedures. Coal fly ash, bottom ash and flue gas desulphurization (FGD) sludge samples were used in the ex...
Gurajada, Navya; Reed, Debra B.; Taylor, Ashlee L.
2017-01-01
Background: In US, approximately 23% of children between the ages of 2-5 years are overweight or obese. Parents need access to information to create healthy home environments for obesity prevention, yet participation for in-person education programs is challenging. Web-based interventions are promising educational tools due to 24/7 availability. However, information is limited on their development and evaluation. Design and Methods: This study reports on a rigorous development process that included six focus group discussions (FGD) with stakeholders (three FGD each with parents and teachers) to assess education needs and inform the development of the Jump2Health Website™ by a multidisciplinary team. After development, the Website was evaluated by telephone interviews with stakeholders (five parents and six teachers) and reviewed by an expert panel of five Registered Dietitians. Results: Twenty Head Start parents and 22 Head Start teachers participated in the FGD. To address the needs identified by these stakeholders, the Website was designed to include components that were enabling and motivating, such as descriptions of health benefits by achieving the desired behaviours, short videos on easy meal preparation, and tip sheets on how to achieve healthy behaviours in easy, economical ways. Stakeholder evaluation of the Website indicated that the information was helpful, easy to use, and would be beneficial for parents. Conclusions: The development of Jump2Health Website™ was strengthened by FGD with stakeholders that assessed educational needs. Interviews with stakeholders and an expert panel review showed that the Website may be an effective educational method to teach parents about healthy behaviours related to obesity prevention. Significance for public health Overweight and obesity in preschool children are at undesirable levels, reflecting a need for parent education programs that address a comprehensive set of obesigenic behaviors (diet, family meals, physical activity, sleep, and screen time) and meet parental needs in terms of accessibility and appeal. Formative evaluation with stakeholders (parents, teachers, and nutrition experts) was useful in shaping the development of the Jump2Health Website™. Websites may be able to overcome some of the challenges of traditional in-person education programs as parents can learn at their own pace and schedule. Parents may be able to obtain information from a website that they would have not felt comfortable asking their paediatrician. Stakeholders suggested that shorter text passages and additional topics on weight control and bullying be included. To provide more access and appeal, a mobile website for smartphones and other supportive materials (newsletters, text messages, and an interactive discussion blog) may be needed. PMID:29291193
FGD uses in agriculture: status of federal regulations and support
USDA-ARS?s Scientific Manuscript database
In 2010 the EPA proposed regulations under RCRA to address the disposal of CCRs. Initially, the EPA proposed two regulatory options: 1) continue to regulate under Subtitle D, or 2) regulate under the more restrictive Subtitle C. After extensive study during the rulemaking process, EPA established r...
The report discusses recent work addressing lime enhancement by slurrying with siliceous materials and testing in a laboratory packed-bed reactor, as part of EPA's efforts to develop low cost, retrofit flue gas cleaning technology, including the development of highly reactive sor...
Speciation, Characterization, And Mobility Of As, Se and Hg In Flue Gas Desulphurization Residues
Flue gas from coal combustion contains significant amounts of volatile toxic trace elements such as arsenic (As), selenium (Se) and mercury (Hg). The capture of these elements in the flue gas desulphurization (FGD) scrubber unit has resulted in generation of a metal-laden residue...
Speciation, Characterization, And Mobility Of As, Se, and Hg In Flue Gas Desulphurization Residues
Flue gas from coal combustion contains significant amounts of volatile elements, such as arsenic (As), selenium (Se) and mercury (Hg), which could lead to serious environmental health risks. The capture of these toxic elements in the scrubber with a flue gas desulphurization (FGD...
Assessment of Mercury in Soils, Crops, Earthworms, and Water when Soil is Treated with Gypsum
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization (FGD) gypsum from fossil fuel combustion has many potential uses in agriculture, but there is concern about the potential environmental effects of its elevated mercury (Hg) concentration. The wet limestone scrubbing process that removes sulfur from flue gas (and produces gyp...
Composting and gypsum amendment of broiler litter to reduce nutrient leaching loss
USDA-ARS?s Scientific Manuscript database
Relative to fresh broiler litter, little is known about the dynamics of composted litter derived-nutrient in the ecosystem. In this study, the potential leaching losses of nutrients from compost relative to fresh broiler litter along with flue gas desulfurization (FGD gypsum), as a nutrient immobil...
NOVEL ECONOMICAL HG(0) OXIDATION REAGENT FOR MERCURY EMISSIONS CONTROL FROM COAL-FIRED BOILERS
The authors have developed a novel economical additive for elemental mercury (Hg0) removal from coal-fired boilers. The oxidation reagent was rigorously tested in a lab-scale fixed-bed column with the Norit America's FGD activated carbon (DOE's benchmark sorbent) in a typical PRB...
ELEMENTAL MERCURY CAPTURE BY ACTIVATED CARBON IN A FLOW REACTOR
The paper gives results of bench-scale experiments in a flow reactor to simulate the entrained-flow capture of elemental mercury (Hgo) using solid sorbents. Adsorption of Hgo by a lignite-based activated carbon (Calgon FGD) was examined at different carbon/mercury (C/Hg) rat...
Hydrologic transport of fecal bacteria attenuated by flue gas desulfurization gypsum
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization (FGD) gypsum is a byproduct of coal-fired power plants. As a soil amendment for crop and pasture production it may increase water infiltration, reduce soil erosion, and decrease nutrient losses from applications of animal manures. Broiler litter is used as a source of plan...
USDA-ARS?s Scientific Manuscript database
Flue gas desulfurization gypsum (FGDG) may be a viable low-cost alternative bedding material for broiler production. In order to evaluate FGD gypsum’s viability, three consecutive trials were conducted to determine its influence on live performance (body weight, feed consumption, feed efficiency, an...
Decreasing phosphorus loss in tile-drained landscapes using flue gas desulfurization gypsum
USDA-ARS?s Scientific Manuscript database
Elevated phosphorus (P) loading from agricultural non-point source pollution continues to impair inland waterbodies throughout the world. The application of flue gas desulfurization (FGD) gypsum to agricultural fields has been suggested to decrease P loading because of its high calcium content and P...
Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Xiao-Ying; Recknagle, Kurtis P.; Glissmeyer, John A.
2013-12-01
In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteriamore » for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.« less
Vertical feed stick wood fuel burning furnace system
Hill, Richard C.
1984-01-01
A new and improved stove or furnace for efficient combustion of wood fuel including a vertical feed combustion chamber for receiving and supporting wood fuel in a vertical attitude or stack, a major upper portion of the combustion chamber column comprising a water jacket for coupling to a source of water or heat transfer fluid and for convection circulation of the fluid for confining the locus of wood fuel combustion to the bottom of the vertical gravity feed combustion chamber. A flue gas propagation delay channel extending from the laterally directed draft outlet affords delayed travel time in a high temperature environment to assure substantially complete combustion of the gaseous products of wood burning with forced air as an actively induced draft draws the fuel gas and air mixture laterally through the combustion and high temperature zone. Active sources of forced air and induced draft are included, multiple use and circuit couplings for the recovered heat, and construction features in the refractory material substructure and metal component superstructure.
NASA Technical Reports Server (NTRS)
Tsuchiya, T.; Murthy, S. N. B.
1982-01-01
A computer code is presented for the prediction of off-design axial flow compressor performance with water ingestion. Four processes were considered to account for the aero-thermo-mechanical interactions during operation with air-water droplet mixture flow: (1) blade performance change, (2) centrifuging of water droplets, (3) heat and mass transfer process between the gaseous and the liquid phases and (4) droplet size redistribution due to break-up. Stage and compressor performance are obtained by a stage stacking procedure using representative veocity diagrams at a rotor inlet and outlet mean radii. The Code has options for performance estimation with (1) mixtures of gas and (2) gas-water droplet mixtures, and therefore can take into account the humidity present in ambient conditions. A test case illustrates the method of using the Code. The Code follows closely the methodology and architecture of the NASA-STGSTK Code for the estimation of axial-flow compressor performance with air flow.
NASA Astrophysics Data System (ADS)
Renfer, Adrian; Tiwari, Manish K.; Brunschwiler, Thomas; Michel, Bruno; Poulikakos, Dimos
2011-09-01
Hydrodynamics in microcavities with cylindrical micropin fin arrays simulating a single layer of a water-cooled electronic chip stack is investigated experimentally. Both inline and staggered pin arrangements are investigated using pressure drop and microparticle image velocimetry (μPIV) measurements. The pressure drop across the cavity shows a flow transition at pin diameter-based Reynolds numbers ( Re d ) ~200. Instantaneous μPIV, performed using a pH-controlled high seeding density of tracer microspheres, helps visualize vortex structure unreported till date in microscale geometries. The post-transition flow field shows vortex shedding and flow impingement onto the pins explaining the pressure drop increase. The flow fluctuations start at the chip outlet and shift upstream with increasing Re d . No fluctuations are observed for a cavity with pin height-to-diameter ratio h/ d = 1 up to Re d ~330; however, its pressure drop was higher than for a cavity with h/d = 2 due to pronounced influence of cavity walls.
16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM ...
16. DOWNSTREAM VIEW OF OUTLET STRUCTURE AND OUTLET CHANNEL, FROM WEST END OF EMBANKMENT. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
50. OUTLET WORKS: OUTLET STRUCTURE PLAN AND SECTIONS. Sheet ...
50. OUTLET WORKS: OUTLET STRUCTURE - PLAN AND SECTIONS. Sheet C-1, September, 1939. File no. SA 343/50. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, ...
21. AERIAL VIEW OF THE OUTLET STRUCTURE AND OUTLET CHANNEL, LOOKING UPSTREAM.... Volume XVII, No. 11, December 26, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
Social disadvantage and exposure to lower priced alcohol in off-premise outlets.
Morrison, Christopher; Ponicki, William R; Smith, Karen
2015-07-01
Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models, we related the minimum purchase price for a 750 mL bottle of wine to a national index of socioeconomic advantage for the census areas in which the outlets were located. Other independent variables characterised outlet features (e.g. volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). A one decile increase in socioeconomic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet and those located in areas with more students also had cheaper alcohol. Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. © 2015 Australasian Professional Society on Alcohol and other Drugs.
Marashi-Pour, Sadaf; Cretikos, Michelle; Lyons, Claudine; Rose, Nick; Jalaludin, Bin; Smith, Joanne
2015-01-01
We explored the association between the density of tobacco outlets and neighbourhood socioeconomic status, and between neighbourhood tobacco outlet density and individual smoking status. We also investigated the density of tobacco outlets around primary and secondary schools in New South Wales (NSW). We calculated the mean density of retail tobacco outlets registered in NSW between 2009 and 2011, using kernel density estimation with an adaptive bandwidth. We used generalised ordered logistic regression model to explore the association between socioeconomic status and density of tobacco outlets. The association between neighbourhood tobacco outlet density and individuals' current smoking status was investigated using random-intercept generalised linear mixed models. We also calculated the median tobacco outlet density around NSW schools. More disadvantaged Census Collection Districts (CDs) were significantly more likely to have higher tobacco outlet densities. After adjusting for neighbourhood socioeconomic status and participants' age, sex, country of birth and Aboriginal status, neighbourhood mean tobacco outlet density was significantly and positively associated with individuals' smoking status. The median of tobacco outlet density around schools was significantly higher than the state median. Policymakers could consider exploring a range of strategies that target tobacco outlets in proximity to schools, in more disadvantaged neighbourhoods and in areas of existing high tobacco outlet density. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.
Brown, Qiana; Milam, Adam J; Bowie, Janice V; Ialongo, Nicholas S; Gaskin, Darrell J; Furr-Holden, Debra
2016-04-01
Tobacco outlet exposure is a correlate of tobacco use with potential differences by gender that warrant attention. The aim of this study is to explore the moderating role of gender in the relationship between tobacco outlet exposure and past month tobacco use among African American young adults 21 to 24 years old. This cross-sectional study (n = 283) used geospatial methods to determine the number of tobacco outlets within walking distance (i.e., a quarter mile) of participants' homes and distance to the nearest outlet. Logistic regression models were used to test interactions between gender and tobacco outlet exposure (i.e., density and proximity). Tobacco outlets were classified based on whether or not they were licensed to sell tobacco only (TO outlets) or tobacco and alcohol (TA outlets). Neither density nor proximity was associated with past month tobacco use in the pooled models. However, gender modified the relationship between TO outlet density and tobacco use, and this relationship was significant only among women (OR = 1.02; p < 0.01; adjusted OR = 1.01; p < 0.05). This study underscores the importance of reducing tobacco outlet density in residential neighborhoods, especially TO outlets, as well as highlights potential gender differences in the relationship between tobacco outlet density and tobacco use.
Audit of tobacco retail outlets in Hangzhou, China.
Gong, Ting; Lv, Jun; Liu, Qingmin; Ren, Yanjun; Li, Liming; Kawachi, Ichiro
2013-07-01
To determine the prevalence of tobacco advertisements and warning messages at points of sale as well as to examine the density of tobacco retail outlets in neighbourhoods and around schools in Hangzhou, China. Tobacco retail outlets (n=1639) in all food and tobacco specialty stores were observed objectively by trained students. Tobacco advertisements and warning messages were assessed with an audit, and stores' addresses were recorded with Global Positioning System coordinates. The distances (1) between all pairs of tobacco retail outlets (2) between each tobacco retail outlet and 15 middle schools were calculated to assess the density of tobacco retail outlets in neighbourhoods and around schools. Among the 1639 tobacco retail outlets, <1% had 'no sales to minors' signs, 1.5% had tobacco warning messages, 28% had signs indicating tobacco sale and 12.4% had tobacco advertisements. For 48.7% of tobacco retail outlets, the nearest distances to other tobacco retail outlets were <50 m. For 80% of schools, there was at least one tobacco retail outlets within a 100 m radius. Tobacco advertisement in retail outlets is prevalent and the density of tobacco retail outlets is high in Hangzhou, China. Signs indicating 'no sales to minors' and tobacco warning signs are almost non-existent. These findings point to an urgent need for the enforcement of regulations on display of 'no sales to minors' and a new density standard for tobacco retail outlets based on protecting the public's health.
Social Disadvantage and Exposure to Lower Priced Alcohol in Off-Premise Outlets
Morrison, Christopher; Ponicki, William R; Smith, Karen
2015-01-01
Introduction and Aims Greater concentrations of off-premise alcohol outlets are found in areas of social disadvantage, exposing disadvantaged populations to excess risk for problems such as assault, child abuse and intimate partner violence. This study examines whether the outlets to which they are exposed also sell cheaper alcohol, potentially further contributing to income-related health disparities. Design and Methods We conducted unobtrusive observations in 295 off-premise outlets in Melbourne, Australia, randomly selected using a spatial sample frame. In semi-logged linear regression models we related the minimum purchase price for a 750ml bottle of wine to a national index of socio-economic advantage for the Census areas in which the outlets were located. Other independent variables characterised outlet features (e.g., volume, chain management) and conditions of the local alcohol market (adjacent outlet characteristics, neighbourhood characteristics). Results A one decile increase in socio-economic advantage was related to a 1.3% increase in logged price. Larger outlets, chains, outlets adjacent to chains, outlets in greater proximity to the nearest neighbouring outlet, those located in areas with more students also had cheaper alcohol. Discussion and Conclusions Not only are disadvantaged populations exposed to more outlets, the outlets to which they are exposed sell cheaper alcohol. This finding appears to be consistent with the spatial dynamics of typical retail markets. PMID:25808717
PROCEEDINGS: SYMPOSIUM ON FLUE GAS DESULFURIZATION HELD AT LAS VEGAS, NEVADA, MARCH 1979; VOLUME II
The publication, in two volumes, contains the text of all papers presented at EPA's fifth flue gas desulfurization (FGD) symposium, March 5-8, 1979, at Las Vegas, Nevada. A partial listing of papers in Volume 2 includes the following: Basin Electric's involvement with dry flue ga...
Applications of selective catalytic reduction (SCR) systems and wet flue gas desulfurization (FGD) scrubbers on coal-fired boilers have led to substantial reductions in emissions of nitrogen oxides (NOX) and sulfur dioxide (SO2). However, observations of pilot- and full-scale tes...
Flue gas desulfurization (FGD) products use on agricultural land
USDA-ARS?s Scientific Manuscript database
Over half of the electricity used in the U.S. is presently produced by burning coal. Currently 114 m mt/year of coal combustion by products (CCP) are produced when coal is burned for generation of electricity. Only about 43% of CCPs currently produced in the U.S. are utilized. Opportunities should b...
Influence of FGD gypsum on the properties of a highly erodible soil under conservation tillage
USDA-ARS?s Scientific Manuscript database
The performance of conservation tillage practices imposed on highly erodible soils may be improved by the use of amendments with a high solubility rate, and whose dissolution products are translocated at depth in the soil profile faster than normally used agricultural lime and fertilizer products. T...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., means a 24-hour period during which fossil fuel is combusted in a steam-generating unit for the entire... another form. Alkaline slurries or solutions used in dry FGD technology include, but are not limited to... CFR 52.21 or under 40 CFR 51.18 and 51.24. Fossil fuel means natural gas, petroleum, coal, and any...
Code of Federal Regulations, 2010 CFR
2010-07-01
..., means a 24-hour period during which fossil fuel is combusted in a steam-generating unit for the entire... another form. Alkaline slurries or solutions used in dry FGD technology include, but are not limited to... CFR 52.21 or under 40 CFR 51.18 and 51.24. Fossil fuel means natural gas, petroleum, coal, and any...
COMPARISON OF WEST GERMAN AND U.S. FLUE GAS DESULFURIZATION AND SELECTIVE CATALYTIC REDUCTION COSTS
The report documents a comparison of the actual cost retrofitting flue gas desulfurization (FGD) and selective catalytic reduction (SCR) on Federal Republic of German (FRG) boilers to cost estimating procedures used in the U.S. to estimate the retrofit of these controls on U.S. b...
Removing soluble phosphorus from agricultural drainage waters using FGD gypsum filters
USDA-ARS?s Scientific Manuscript database
Decades of applying chicken litter to meet nitrogen demand has led to accumulation of phosphorus (P) in soils of the Delmarva Peninsula. This legacy P that now approaches levels up to ten times the agronomic optimum is a major source of P entering drainage ditches that eventually empty into the Ches...
Current methods designed to control and reduce the amount of sulfur dioxide emitted into the atmosphere from coal-fired power plants and factories rely upon the reaction between SO2 and alkaline earth compounds and are called flue gas desulfurization (FGD) processes. Of these met...
Duet for menstrual protection: a feasibility study in Zimbabwe.
Averbach, Sarah; Sahin-Hodoglugil, Nuriye; Musara, Petina; Chipato, Tsungai; van der Straten, Ariane
2009-06-01
Managing menses is a challenge for women in developing countries. Duet is a cervical barrier being developed for contraception and STI prevention. We explored the hypothetical acceptability of using Duet as a menstrual cup, among Zimbabwean women. A survey and focus group discussions (FGD) were conducted with 43 women aged 18-45 years to gain information about their menstrual practices and attitudes regarding the use of Duet for menstrual protection. All 43 women reported that if Duet were available, they would "definitely" try it, and that it was "very important" that Duet is low cost and easy to clean; 86% reported that using it would make a difference in their lives. FGD findings highlighted unhygienic practices due to the lack of affordable options for menstrual management and a genuine interest in Duet, including its potential use for multiple purposes (contraception, disease prevention and menstrual protection). Accessing affordable and hygienic menstrual protection was a problem for these Zimbabwean women. Duet appeared acceptable and it would be feasible to conduct a user-acceptability study of Duet as a menstrual cup in Zimbabwe.
[Mechanism and technology of recovery flue gas desulphurization with magnesium oxide].
Cui, Ke; Chai, Ming; Xu, Kang-fu; Ma, Yong-liang
2006-05-01
Taking magnesium oxide slurry as absorption solution, the simulation of bubbling absorption process of mixed SO2 gases was observed in laboratory. Experiment results show that with a high efficiency and stable situation, acidification of absorbing solution was caused by HSO3-; the acidification trend was in accordance with the pattern of hydrolyzing of SO2, pH changes slowly at high pH value with SO3(2-) and rapidly at low value with HSO3-. The experiments also show the insensitive effect of liquid temperature on the high desulphurization efficiency. With relatively high dissolution rate and oxidizability of MgSO3 as well as the high solubility of MgSO4, the desulphurization efficiency utilization of MgO. Industrial experiment of FGD of coal-fired boiler showed that by recycling absorbing liquid could be raised to the concentration of MgSO4 to the saturation concentration at the operation temperature (40-50 degrees C) without any adverse effects on FGD efficiency. Refinement and enrichment of active substance could promote the desulphurization process, thus showed the availability of technical and economy feasibility of recovery technology.
Liu, Guorui; Zhan, Jiayu; Zheng, Minghui; Li, Li; Li, Chunping; Jiang, Xiaoxu; Wang, Mei; Zhao, Yuyang; Jin, Rong
2015-12-15
A pilot study was performed to evaluate formation, distribution and emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from cement kilns that co-process fly ash from municipal solid waste incineration (MSWI). Stack gas and particulate samples from multiple stages in the process were collected and analyzed for PCDD/Fs. Stack emissions of PCDD/Fs were below the European Union limit for cement kilns (0.1 ng TEQ m(-3)). PCDD/F concentrations in particulates from the cyclone preheater outlet, suspension preheater boiler, humidifier tower, and back-end bag filter were much higher than in other samples, which suggests that these areas are the major sites of PCDD/F formation. Comparison of PCDD/F homolog and congener profiles from different stages suggested that tetra- and penta-chlorinated furans were mainly formed during cement kiln co-processing of MSWI fly ash. Three lower chlorinated furan congeners, including 2,3,7,8-tetrachlorodibenzofuran, 1,2,3,7,8-pentachlorodibenzo-p-dioxin and 2,3,4,7,8-pentachlorodibenzofuran, were identified as dominant contributors to the toxic equivalents (TEQ) of the PCDD/Fs. The concentration of PCDD/Fs in particulates was correlated with chloride content, which is consistent with its positive effect on PCDD/F formation. This could be mitigated by pretreating the feedstock to remove chloride and metals. Mass balance indicated that cement kilns eliminated about 94% of the PCDD/F TEQ input from the feedstock. Copyright © 2015 Elsevier B.V. All rights reserved.
Using virtual worlds for patient and public engagement
Taylor, Michael J.; Kaur, Meerat; Sharma, Uvarshi; Taylor, Dave; Reed, Julie E.; Darzi, Ara
2015-01-01
Patient and public involvement is fundamental in healthcare and many methods attempt to facilitate this engagement. The present study investigated use of computer-generated environments known as ‘virtual worlds’ (VW) as an involvement method. The VW used in the present research was Second Life, which is 3-dimensional, publically accessible and internet-based. It is accessed using digital self-representations, or ‘avatars’, through which users navigate the virtual environment and communicate with one another. Participants were patients with long-term conditions, frequently involved in shaping health research and care. Some had mobility and communication difficulties, potentially making involvement through traditional face-to-face modes of engagement challenging. There were 2 stages to this study. Stage-1: Participants were introduced to VWs and Second Life. This was followed by a face-to-face focus group discussion (FGD) in order to gain their views on use of SL. Stage-2: An FGD attended by 8 people (4 patients, 3 researchers, 1 healthcare professional) was conducted in Second Life. Training and support on using Second Life had been provided for participants. The FGD took place successfully, although some technical and communication difficulties were experienced. Data was collected in the form of interviews and questionnaires from the patients about their experience of using the virtual world. Participants recognised the potential of VWs as a platform for patient engagement, especially for those who suffer from chronic conditions that impact severely upon their mobility and communication. Participant feedback indicated that potential barriers include technical problems with VW programs and potential user inexperience of using VWs, which may be counteracted by ensuring provision of continuous training and support. In conclusion, this study established the feasibility of using VWs for patient FGDs and indicates a potential of use of VWs for engagement in future, particularly for peer-led support and to engage people with particular long-term conditions. PMID:26543506
Cultural challenges to implementation of formative assessment in Saudi Arabia: an exploratory study.
Al-Wassia, Rolina; Hamed, Omayma; Al-Wassia, Heidi; Alafari, Reem; Jamjoom, Reda
2015-04-01
This study investigates challenges that students and faculty face to implement assessment for learning; and the activities, capabilities, enablers, and indicators which could impact performance. The study is a mixed methods research, cross-sectional, exploratory study. The study was organized through two phases of data collection and analysis (QUAL → quan). Based on qualitative focus group discussions (FGD), we first gathered data through field notes. Later, we engaged in analysis using techniques drawn from qualitative data including categorization, theme identification, and connection to existing literature. Based on this analysis, we developed a questionnaire that could provide quantitative measures based on the qualitative FGD. We then administered the questionnaire, and the quantitative data were analyzed to quantitatively test the qualitative findings. Twenty-four faculty and 142 students from the 4th and 5th clinical years participated voluntarily. Their perception of FA and the cultural challenges that hinder its adoption were evaluated through a FGD and a questionnaire. The mean score of understanding FA concept was equal in faculty and students (p = 0.08). The general challenge that scored highest was the need to balance work and academic load in faculty and the need to balance study load and training and mental anxiety in students. There was no difference between faculty and students in perceiving "learning is teacher-centered" (p = 0.481); and "past learning and assessment experience" (p = 0.322). There was a significant difference between them regarding interaction with opposite gender (p <0.001). Students showed higher value as regards the "gap between learning theories and assessment practice", "grade as a priority", and "discrimination by same faculty gender". The authors suggested a "Framework of Innovation in Endorsing Assessment for Learning". It emphasizes a holisitic approach through all levels of the System: Government, Accreditation Bodies, Policy makers; Institution, and Classroom levels.
Paz-Soldan, Valerie A; Yukich, Josh; Soonthorndhada, Amara; Giron, Maziel; Apperson, Charles S; Ponnusamy, Loganathan; Schal, Coby; Morrison, Amy C; Keating, Joseph; Wesson, Dawn M
2016-01-01
Dengue virus (and Chikungunya and Zika viruses) is transmitted by Aedes aegypti and Aedes albopictus mosquitoes and causes considerable human morbidity and mortality. As there is currently no vaccine or chemoprophylaxis to protect people from dengue virus infection, vector control is the only viable option for disease prevention. The purpose of this paper is to illustrate the design and placement process for an attractive lethal ovitrap to reduce vector populations and to describe lessons learned in the development of the trap. This study was conducted in 2010 in Iquitos, Peru and Lopburi Province, Thailand and used an iterative community-based participatory approach to adjust design specifications of the trap, based on community members' perceptions and feedback, entomological findings in the lab, and design and research team observations. Multiple focus group discussions (FGD) were held over a 6 month period, stratified by age, sex and motherhood status, to inform the design process. Trap testing transitioned from the lab to within households. Through an iterative process of working with specifications from the research team, findings from the laboratory testing, and feedback from FGD, the design team narrowed trap design options from 22 to 6. Comments from the FGD centered on safety for children and pets interacting with traps, durability, maintenance issues, and aesthetics. Testing in the laboratory involved releasing groups of 50 gravid Ae. aegypti in walk-in rooms and assessing what percentage were caught in traps of different colors, with different trap cover sizes, and placed under lighter or darker locations. Two final trap models were mocked up and tested in homes for a week; one model was the top choice in both Iquitos and Lopburi. The community-based participatory process was essential for the development of novel traps that provided effective vector control, but also met the needs and concerns of community members.
Utilization of the gypsum from a wet limestone flue gas desulfurization process
Chou, I.-Ming; Patel, V.; Lytle, J.M.; Chou, S.J.; Carty, R.H.
1999-01-01
The authors have been developing a process which converts FGD-gypsum to ammonium sulfate fertilizer with precipitated calcium carbonate as a by-product during the conversion. Preliminary cost estimates suggest that the process is economically feasible when ammonium sulfate crystals are produced in a granular size (1.2 to 3.3 mm), instead of a powder form. However, if additional revenue from the sale of the PCC for higher-value commercial application is applicable, this could further improve the economics of the process. Ammonium sulfate is known to be an excellent source of nitrogen and sulfur in fertilizer for corn and wheat production. It was not known what impurities might co-exist in ammonium sulfate derived from scrubber gypsum. Before the product could be recommended for use on farm land, the impurities and their impact on soil productivity had to be assessed. The objectives of this phase of the study were to evaluate the chemical properties of ammonium sulfate made from the FGD-gypsum, to estimate its effects on soil productivity, and to survey the marketability of the two products. The results of this phase of the study indicated that the impurities in the ammonium sulfate produced would not impose any practical limitations on its use at application levels used by farmers. The market survey showed that the sale price of solid ammonium sulfate fertilizer increased significantly from 1974 at $110/ton to 1998 at $187/ton. Utilities currently pay $16 to $20/ton for the calcium carbonate they use in their flue gas scrubber system. The industries making animal-feed grade calcium supplement pay $30/ton to $67/m-ton for their source of calcium carbonate. Paper, paint, and plastic industries pay as much as $200 to $300/ton for their calcium carbonate filers. The increased sale price of solid ammonium sulfate fertilizer and the possible additional revenue from the sale of the PCC by-product could further improve the economics of producing ammonium sulfate from FGD-gypsum.
Communication of geohazard risks by focus group discussions in the Mount Cameroon area, Cameroon.
NASA Astrophysics Data System (ADS)
del Marmol, M.-A.; Suh Atanga, M. Bi; Njome, S.; Mafany Teke, G.; Jacobs, P.; Suh, C. E.
2012-04-01
The inappropriate translation of scientific information of geohazard (volcanic, landslide and crater lake outgassing) risks to any local population leaves people with incongruent views of the real dangers. Initial workshops organized under the supervision of the VLIR-OI (Flemish Interuniversity Council - Own Initiatives) members have led to the deployment of billboards as requested and drawn up by the locals. The VLIR-OI project has also organized focus group discussions (FGD) with the local stakeholders to find out in various cities, the state of preparedness, the response to emergency situations, the recovery from the emergency and the mitigation. Researchers have preferred open discussion with the local population and its representatives in order to elicit information that otherwise might not be found on a structured questionnaire. FGD provide a meaningful interactive opportunity to collect information and reflection on a wide range of input. The method provides an insight into problems that require a solution through a process of discovering the meaning attributed to certain events or issues. In this research four cardinal points as preparedness, response, recovery and mitigation (Fothergill, 1996) guided the FGD. The population (i.e. local town councils) were constituted by a mix of chiefs, engineers, technicians and civil servants and government officials. In all the three city councils concerned, the engineers in charge complained about the lack of strategic planning, and about the missing of an elaborated strategy for disasters. They are aware of the existence of an organigram in the "Département de l'Action Civile" in Yaounde but never received any "strategic" document. Therefore inappropriate actions might be taken by the municipalities themselves. Fortunately all people interrogated at the FDG always mentioned solidarity in any event. Fothergill, 1996, Gender, Risk, and Disasters, Intern. Jour. of Mass Emergencies and Disasters, vol.14, n°1, 33-56
Yukich, Josh; Soonthorndhada, Amara; Giron, Maziel; Apperson, Charles S.; Ponnusamy, Loganathan; Schal, Coby; Morrison, Amy C.; Keating, Joseph; Wesson, Dawn M.
2016-01-01
Background Dengue virus (and Chikungunya and Zika viruses) is transmitted by Aedes aegypti and Aedes albopictus mosquitoes and causes considerable human morbidity and mortality. As there is currently no vaccine or chemoprophylaxis to protect people from dengue virus infection, vector control is the only viable option for disease prevention. The purpose of this paper is to illustrate the design and placement process for an attractive lethal ovitrap to reduce vector populations and to describe lessons learned in the development of the trap. Methods This study was conducted in 2010 in Iquitos, Peru and Lopburi Province, Thailand and used an iterative community-based participatory approach to adjust design specifications of the trap, based on community members’ perceptions and feedback, entomological findings in the lab, and design and research team observations. Multiple focus group discussions (FGD) were held over a 6 month period, stratified by age, sex and motherhood status, to inform the design process. Trap testing transitioned from the lab to within households. Results Through an iterative process of working with specifications from the research team, findings from the laboratory testing, and feedback from FGD, the design team narrowed trap design options from 22 to 6. Comments from the FGD centered on safety for children and pets interacting with traps, durability, maintenance issues, and aesthetics. Testing in the laboratory involved releasing groups of 50 gravid Ae. aegypti in walk-in rooms and assessing what percentage were caught in traps of different colors, with different trap cover sizes, and placed under lighter or darker locations. Two final trap models were mocked up and tested in homes for a week; one model was the top choice in both Iquitos and Lopburi. Discussion The community-based participatory process was essential for the development of novel traps that provided effective vector control, but also met the needs and concerns of community members. PMID:27532497
24 CFR 3280.806 - Receptacle outlets.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., 125-volt, either single or duplex. (b) All 120 volt single phase, 15 and 20 ampere receptacle outlets... Receptacle outlets. (b) All 125-volt, single-phase, 15- and 20-ampere receptacle outlets installed outdoors... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Receptacle outlets. 3280.806...
5 CFR 591.217 - In which outlets does OPM collect prices?
Code of Federal Regulations, 2010 CFR
2010-01-01
... popular outlets in each survey area. OPM selects these outlets based on their proximity to the housing... that reflect sales volume. To the extent practical, OPM prices like items in the same types of outlets... surveys and select outlets based on the results of those surveys. ...
Young, Robert; Macdonald, Laura; Ellaway, Anne
2013-01-01
Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. Copyright © 2012 Elsevier Ltd. All rights reserved.
Young, Robert; Macdonald, Laura; Ellaway, Anne
2013-01-01
Associations between different alcohol outcomes and outlet density measures vary between studies and may not be generalisable to adolescents. In a cross-sectional study of 979 15-year old Glaswegians, we investigated the association between alcohol outlet availability (outlet density and proximity), outlet type (on-premise vs. off-premise) and frequent (weekly) alcohol consumption. We adjusted for social background (gender, social class, family structure). Proximity and density of on-premise outlets were not associated with weekly drinking. However, adolescents living close (within 200 m) to an off-sales outlet were more likely to drink frequently (OR 1.97, p=0.004), as were adolescents living in areas with many nearby off-premises outlets (OR 1.60, p=0.016). Our findings suggest that certain alcohol behaviours (e.g. binge drinking) may be linked to the characteristics of alcohol outlets in the vicinity. PMID:23220375
Zhang, Xingyou; Hatcher, Bonnie; Clarkson, Lydia; Holt, James; Bagchi, Suparna; Kanny, Dafna; Brewer, Robert D
2015-05-28
Regulating alcohol outlet density is an evidence-based strategy for reducing excessive drinking. However, the effect of this strategy on violent crime has not been well characterized. A reduction in alcohol outlet density in the Buckhead neighborhood of Atlanta from 2003 through 2007 provided an opportunity to evaluate this effect. We conducted a community-based longitudinal study to evaluate the impact of changes in alcohol outlet density on violent crime in Buckhead compared with 2 other cluster areas in Atlanta (Midtown and Downtown) with high densities of alcohol outlets, from 1997 through 2002 (preintervention) to 2003 through 2007 (postintervention). The relationship between exposures to on-premises retail alcohol outlets and violent crime were assessed by using annual spatially defined indices at the census block level. Multilevel regression models were used to evaluate the relationship between changes in exposure to on-premises alcohol outlets and violent crime while controlling for potential census block-level confounders. A 3% relative reduction in alcohol outlet density in Buckhead from 1997-2002 to 2003-2007 was associated with a 2-fold greater reduction in exposure to violent crime than occurred in Midtown or Downtown, where exposure to on-premises retail alcohol outlets increased. The magnitude of the association between exposure to alcohol outlets and violent crime was 2 to 5 times greater in Buckhead than in either Midtown or Downtown during the postintervention period. A modest reduction in alcohol outlet density can substantially reduce exposure to violent crime in neighborhoods with high density of alcohol outlets. Routine monitoring of community exposure to alcohol outlets could also inform the regulation of alcohol outlet density, consistent with Guide to Community Preventive Services recommendations.
Relating off-premises alcohol outlet density to intentional and unintentional injuries.
Morrison, Christopher; Smith, Karen; Gruenewald, Paul J; Ponicki, William R; Lee, Juliet P; Cameron, Peter
2016-01-01
This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Ecological cross-sectional. From the 256 Statistical Area level 2 (SA2) census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. The selected units contained 295 off-premises outlets. Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price) and other operating characteristics (chain versus independent, drive-through). Outlet counts, assessed outlet characteristics and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries and object strikes). In univariable analyses, chain outlets were larger (r = 0.383; P < 0.001) and sold cheaper alcohol (r = -0.484; P < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional [incidence rate ratio (IRR) = 1.38; 95% credible interval (CI) = 1.19, 1.60] and unintentional injuries (IRR = 1.18; 95% CI = 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI = 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI = 1.08, 1.38). Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets appear to contribute most substantially to traumatic injury risk. © 2015 Society for the Study of Addiction.
Relating Off-Premises Alcohol Outlet Density to Intentional and Unintentional Injuries
Morrison, Christopher; Smith, Karen; Gruenewald, Paul J.; Ponicki, William R.; Lee, Juliet P.; Cameron, Peter
2015-01-01
Aims This study investigated the hypotheses that (i) intentional and unintentional injuries occur more frequently in areas with greater density of off-premises alcohol outlets; and (ii) larger and chain outlets selling cheaper alcohol contribute more substantially to injury risk than smaller and independent outlets. Design Ecological cross-sectional. Setting From the 256 Statistical Area level 2 (SA2) Census units in Melbourne, Australia, we selected a random sample of 62 units. There were 2,119 Statistical Area level 1 (SA1) units nested within the selected SA2 units. Participants The selected units contained 295 off-premises outlets. Measurements Two independent observers conducted premises assessments in all off-premises outlets, assessing the volume of alcohol available for sale (paces of shelf space), price (least wine price), and other operating characteristics (chain vs. independent, drive-through). Outlet counts, assessed outlet characteristics, and other area characteristics (population density, median age, median income, retail zoning) were aggregated within SA1 units. Dependent variables were counts of ambulance attended intentional injuries (assaults, stabbings, shootings) and unintentional injuries (falls, crush injuries, and object strikes). Findings In univariable analyses, chain outlets were larger (r = 0.383; p < 0.001) and sold cheaper alcohol (r = −0.484; p < 0.001) compared with independent outlets. In Bayesian spatial Poisson models, off-premises outlet density was positively related to both intentional (Incidence Rate Ratio = 1.38; 95% Credible Interval: 1.19, 1.60) and unintentional injuries (IRR = 1.18; 95% CI: 1.06, 1.30). After disaggregation by outlet characteristics, chain outlet density was also related to both intentional (IRR = 1.35; 95% CI: 1.11, 1.64) and unintentional injuries (IRR = 1.20; 95% CI: 1.08, 1.38). Conclusions Greater off-premises outlet density is related to greater incidence of traumatic injury, and chain outlets appear to contribute most substantially to traumatic injury risk. PMID:26283189
Liang, Wenbin; Chikritzhs, Tanya
2011-09-01
Associations between alcohol-related harms and numbers of outlets at the neighbourhood level have been demonstrated; however, the degree to which alcohol consumption or sales plays a part in levels of violence is not clear. This has contributed to uncertainty regarding the actual mechanisms by which outlet density may influence levels of violence. This ecological cross-sectional study investigated the effect of outlet numbers and alcohol sales on the risk of assault in Western Australia. For 2000/2001, information on type, number and wholesale alcohol purchases of all licensed outlets in operation, police-reported assault offences, socioeconomic/demographic data were obtained from official sources. Multivariate negative binomial regression was applied to at local government area level in order to assess associations between outlet density, alcohol sales and violence occurring in both licensed and domestic settings. Average alcohol sales volume per off-site outlet was significantly associated with all measures of assault. Numbers of on-site outlets significantly predicted violence with the exception of assaults occurring at residential premises. Alcohol sales from off-site outlets predicted violence occurring at on-site outlets. The link between on-site outlets and violence may be primarily underpinned by negative amenity effects while off-site outlet effects occur via increased availability. Alcohol sales volumes from off-site outlets influence levels of violence, which occur at both licensed and residential settings. The substantial and wide-ranging effects of liquor stores on alcohol-related harms may have been underestimated in the literature and by policy makers. © 2011 Australasian Professional Society on Alcohol and other Drugs.
Fakunle, D O; Milam, A J; Furr-Holden, C D; Butler, J; Thorpe, R J; LaVeist, T A
2016-07-01
Studies have shown that communities with higher concentrations of low-income racial and ethnic minorities correlate with a greater presence of tobacco outlets. Community-level income has consistently been among the strongest predictors of tobacco outlet density. This study analyzes two Maryland geopolitical areas with similar racial concentrations yet differing income levels in an attempt to disentangle the race-income relationship with tobacco outlet density. In this cross-sectional examination of tobacco outlet and census tract-level sociodemographic data, Baltimore City, Maryland, and Prince George's County, Maryland, were geocoded to determine tobacco outlet density. Tobacco outlet density was defined as the mean number of tobacco outlets per 1000 persons per census tract. Comparisons of tobacco outlet density and sociodemographic variables were analysed via two-sample t-tests, and the direct effect of sociodemographic variables on tobacco outlet density for each area was analysed via spatial lag regressions. Prince George's County, the area with the higher income level ($77,190 vs $43,571), has a significantly lower tobacco outlet density than Baltimore City (P < 0.001). Prince George's County has a 67.5% Black population and an average of 3.94 tobacco outlets per 1000 persons per tract. By contrast, Baltimore City has a 65.3% Black population and an average of 7.95 tobacco outlets per 1000 persons per tract. Spatial lag regression model results indicate an inverse relationship between income and tobacco outlet density in Baltimore City and Prince George's County (β = -0.03, P < 0.01 &β = -0.01, P = 0.02, respectively), and a significant interaction term indicating a greater magnitude in the relationship between income and tobacco outlet density in Baltimore City (β = -0.05, P < 0.01). Results suggest that higher socio-economic status, even in primarily underrepresented racial and ethnic geopolitical areas, is linked to lower tobacco outlet density. Copyright © 2016 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A pilot-scale field study was carried out to investigate the distribution of Hg and other selected elements in the three potential mitigation pathways, i.e., emission to ambient air, uptake by surface vegetation (i.e., grass), and rainfall infiltration, after flue gas desulfurization (FGD) material ...
The report, the fifth of five volumes, focuses on disposal of coal ash and FGD wastes which (together) comprise FGC wastes. The report assesses the various options for the disposal of FGC wastes with emphasis on disposal on land. A number of technical, economic, and regulatory fa...
ERIC Educational Resources Information Center
Dalanon, Junhel; Diano, Liz Muriel; Belarmino, Ma Paciencia; Hayama, Rika; Miyagi, Mayu; Matsuka, Yoshizo
2018-01-01
This 2016 cross-sectional inquiry used quantitative and thematic content analysis to determine the organizational climate (OC) with empirical and theoretical relation to the teachers' performance (TP) and management competencies (MC) of a rural, K-12, private school in the Philippines. Analyses from a focus group discussion (FGD) was done using…
ERIC Educational Resources Information Center
Onwuegbuzie, Anthony J.; Frels, Rebecca K.
2015-01-01
Although focus group discussions (FGDs) represent a popular data collection tool for researchers, they contain an extremely serious flaw: FGD researchers have ultimate power over all decisions made at every stage of the research process--from the conceptualization of the research, to the planning of the research study, to the implementation of the…
USDA-ARS?s Scientific Manuscript database
Gypsum has various potential benefits as a soil amendment, but data are lacking on gypsum effects on crop yields and on environmental impacts across diverse field sites. Gypsum studies were conducted in six states using a common design with three rates each of mined and flue gas desulfurization (FGD...
USDA-ARS?s Scientific Manuscript database
A study was conducted to evaluate the growth response and consumer preference of three plant species to substrate blends containing flue gas desulfurization gypsum (FGDG). Substrate blends used in this study were derived from a previous experiment that evaluated the use of FGD Gas a bedding material...
2002-06-01
Interior’s Bureau of Land Management (BLM). Flue - Gas Desulfurization (FGD). Post-combustion sulfur dioxide control technology in which a scrubber...4. Individual Control Strategies for Toxic Pollutants. a. The CWA requires states to identify “impaired” water bodies within their...water quality standards. Thereafter, states must develop “individual control strategies ” (ICSs) to regulate such pollutants and achieve water quality
1991-10-01
Agency FFA Federal Facilities Agreement FFCA Federal Facilities Compliance Agreement FGD Flue Gas Desulfurization FIFRA Federal Insecticide, Fungicide...carrying out response. If none, state why. EXAMPLE: Gas barriers used to control and contain vapor emissions. Runoff contained by excavating ditch...NPDES PERMITS 20-2 2006 WATER QUALITY STANDARDS 20-2 2007 POLLUTION CONTROL TECHNOLOGY 20-3 2008 TECHNOLOGY VARIANCE AND MODIFICATIONS 20-4 2009
1995-11-01
jurisdiction of the Department of the Interior’s Bureau of Land Management (BLM). Flue - Gas Desulfurization (FGD). Post-combustion sulfur dioxide control ...National Pollution Discharge Elimination System Permits .......... 11 VIII Individual Control Strategies for Toxic Pollutants (ICS) ........... 14 IX Storm...individual control strategies be integrated into the sources’ NPDES permits. EPA has established water quality standards for a number of toxic
ERIC Educational Resources Information Center
Geary, Cynthia Waszak; Burke, Holly M.; Johnson, Laura; Liku, Jennifer; Castelnau, Laure; Neupane, Shailes; Niang, Cheikh
2008-01-01
To examine young people's reactions to and understanding of HIV prevention messages developed for MTV's global HIV prevention campaign Staying Alive, videotaped campaign materials were shown to focus group discussion (FGD) participants living in urban areas of Brazil, Kenya, Nepal, and Senegal. Responses related to "personal involvement"…
Failure mode analysis for lime/limestone FGD system. Volume III. Plant profiles. Part 1 of 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenney, S.M.; Rosenberg, H.S.; Nilsson, L.I.O.
1984-08-01
This volume contains plant profiles for: Petersburg 3; Hawthorn 3, 4; La Cygne 1; Jeffry 1, 2; Lawrence 4, 5; Green River 1-3; Cane Run 4, 5; Mill Creek 1, 3; Paddy's Run 6; Clay Boswell 4; Milton R. Young 2; Pleasants 1, 2; and Colstrip 1, 2. (DLC)
The report describes a mini-pilot test program to investigate potential new sorbents and processes for dry SO2 removal. Initial tests showed that the 85 cu m/h pilot plant could be used successfully to evaluate both spray dryer and dry injection processes using traditional calciu...
40 CFR 60.50Da - Compliance determination procedures and methods.
Code of Federal Regulations, 2011 CFR
2011-07-01
... after wet FGD systems if the effluent is saturated or laden with water droplets. (2) The Fc factor (CO2...) Electric utility combined cycle gas turbines that are not designed to burn fuels containing 50 percent (by... emission rates calculations from the gas turbine used in Method 19 of appendix A-7 of this part are...
Availability of limited service food outlets surrounding schools in British Columbia.
Black, Jennifer L; Day, Meghan
2012-06-05
The purpose of this study was to provide a descriptive profile of the availability of limited service food outlets surrounding public schools in British Columbia, Canada. Data from the 2010 Canadian Business Data Files were used to identify limited service food outlets including fast food outlets, beverage and snack food stores, delis and convenience stores. The number of food outlets within 800 metres of 1,392 public schools and the distance from schools to the nearest food outlets were assessed. Multivariate regression models examined the associations between food outlet availability and school-level characteristics. In 2010, over half of the public schools in BC (54%) were located within a 10-12 minute walk from at least one limited service food outlet. The median closest distance to a food outlet was just over 1 km (1016 m). Schools comprised of students living in densely populated urban neighbourhoods and neighbourhoods characterized by lower socio-economic status were more likely to have access to limited service food outlets within walking distance. After adjusting for school-level median family income and population density, larger schools had higher odds of exposure to food vendors compared to schools with fewer students. The availability of and proximity to limited service food outlets vary widely across schools in British Columbia and school-level characteristics are significantly associated with food outlet availability. Additional research is needed to understand how food environment exposures inside and surrounding schools impact students' attitudes, food choices and dietary quality.
Fischer, Harry C.
1977-01-01
This invention is a reversing valve having an inlet, an outlet, and an inlet-outlet port. The valve is designed to respond to the introduction of relatively high-pressure fluid at its inlet or, alternatively, of lower-pressure fluid at its inlet-outlet port. The valve includes an axially slidable assembly which is spring-biased to a position where it isolates the inlet and connects the inlet-outlet port to the outlet. The admission of high-pressure fluid to the inlet displaces the slidable assembly to a position where the outlet is isolated and the inlet is connected to the inlet-outlet port. The valve is designed to minimize pressure drops and leakage. It is of a reliable and comparatively simple design.
Effects of Outlets on Cracking Risk and Integral Stability of Super-High Arch Dams
Hu, Hang
2014-01-01
In this paper, case study on outlet cracking is first conducted for the Goupitan and Xiaowan arch dams. A nonlinear FEM method is then implemented to study effects of the outlets on integral stability of the Xiluodu arch dam under two loading conditions, i.e., normal loading and overloading conditions. On the basis of the case study and the numerical modelling, the outlet cracking mechanism, risk, and corresponding reinforcement measures are discussed. Furthermore, the numerical simulation reveals that (1) under the normal loading conditions, the optimal distribution of the outlets will contribute to the tensile stress release in the local zone of the dam stream surface and decrease the outlet cracking risk during the operation period. (2) Under the overloading conditions, the cracks initiate around the outlets, then propagate along the horizontal direction, and finally coalesce with those in adjacent outlets, where the yield zone of the dam has a shape of butterfly. Throughout this study, a dam outlet cracking risk control and reinforcement principle is proposed to optimize the outlet design, select the appropriate concrete material, strengthen the temperature control during construction period, design reasonable impounding scheme, and repair the cracks according to their classification. PMID:25152907
Rosenberg, Molly; Pettifor, Audrey; Lippman, Sheri A; Thirumurthy, Harsha; Emch, Michael; Miller, William C; Selin, Amanda; Gómez-Olivé, Francesc Xavier; Hughes, James P; Laeyendecker, Oliver; Tollman, Stephen; Kahn, Kathleen
2015-05-01
Exposure to alcohol outlets may influence sexual health outcomes at the individual and community levels. Visiting alcohol outlets facilitates alcohol consumption and exposes patrons to a risky environment and network of potential partners, whereas the presence of alcohol outlets in the community may shift social acceptance of riskier behavior. We hypothesize that living in communities with more alcohol outlets is associated with increased sexual risk. We performed a cross-sectional analysis in a sample of 2174 South African schoolgirls (ages 13-21 years) living across 24 villages in the rural Agincourt subdistrict, underpinned by long-term health and sociodemographic surveillance. To examine the association between number of alcohol outlets in village of residence and individual-level prevalent herpes simplex virus type 2 (HSV-2) infection, we used generalized estimating equations with logit links, adjusting for individual- and village-level covariates. The median number of alcohol outlets per village was 3 (range, 0-7). Herpes simplex virus type 2 prevalence increased from villages with no outlets (1.4% [95% confidence interval, 0.2-12.1]), to villages with 1 to 4 outlets (4.5% [3.7-5.5]), and to villages with more than 4 outlets (6.3% [5.6, 7.1]). An increase of 1 alcohol outlet per village was associated with an 11% increase in the odds of HSV-2 infection (adjusted odds ratio [95% confidence interval], 1.11 [0.98-1.25]). Living in villages with more alcohol outlets was associated with increased prevalence of HSV-2 infection in young women. Structural interventions and sexual health screenings targeting villages with extensive alcohol outlet environments could help prevent the spread of sexually transmitted infections.
Deierlein, Andrea L; Galvez, Maida P; Yen, Irene H; Pinney, Susan M; Biro, Frank M; Kushi, Lawrence H; Teitelbaum, Susan; Wolff, Mary S
2014-10-01
To describe availability and frequency of use of local snack-food outlets and determine whether reported use of these outlets was associated with dietary intakes. Data were cross-sectional. Availability and frequency of use of three types of local snack-food outlets were reported. Daily dietary intakes were based on the average of up to four 24 h dietary recalls. Multivariable linear regression models estimated average daily intakes of energy, sugar-sweetened beverages (SSB) and snack foods/sweets associated with use of outlets. Multi-site, observational cohort study in the USA, 2004-2006. Girls aged 6-8 years (n 1010). Weekly frequency of use of local snack-food outlets increased with number of available types of outlets. Girls with access to only one type of outlet reported consuming food/beverage items less frequently than girls with access to two or three types of outlets (P <0·001). Girls' daily energy, SSB and snack foods/sweets intakes increased with greater use of outlets. Girls who reported using outlets>1 to 3 times/week consumed 0·27 (95 % CI 0·13, 0·40) servings of SSB more daily than girls who reported no use. Girls who reported using outlets>3 times/week consumed 449·61 (95 % CI 134·93, 764·29) kJ, 0·43 (95 % CI 0·29, 0·58) servings of SSB and 0·38 (95 % CI 0·12, 0·65) servings of snack foods/sweets more daily than those who reported no use. Girls' frequency of use of local snack-food outlets increases with the number of available types of outlets and is associated with greater daily intakes of energy and servings of SSB and snack foods/sweets.
Snowden, Aleksandra J; Freiburger, Tina L
2015-05-01
We estimated spatially lagged regression and spatial regime models to determine if the variation in total, on-premise, and off-premise alcohol outlet(1) density is related to robbery density, while controlling for direct and moderating effects of social disorganization.(2) Results suggest that the relationship between alcohol outlet density and robbery density is sensitive to the measurement of social disorganization levels. Total alcohol outlet density and off-premise alcohol outlet density were significantly associated with robbery density when social disorganization variables were included separately in the models. However, when social disorganization levels were captured as a four item index, only the association between off-premise alcohol outlets and robbery density remained significant. More work is warranted in identifying the role of off-premise alcohol outlets and their characteristics in robbery incidents. Copyright © 2015 Elsevier Inc. All rights reserved.
Organic flash cycles for efficient power production
Ho, Tony; Mao, Samuel S.; Greif, Ralph
2016-03-15
This disclosure provides systems, methods, and apparatus related to an Organic Flash Cycle (OFC). In one aspect, a modified OFC system includes a pump, a heat exchanger, a flash evaporator, a high pressure turbine, a throttling valve, a mixer, a low pressure turbine, and a condenser. The heat exchanger is coupled to an outlet of the pump. The flash evaporator is coupled to an outlet of the heat exchanger. The high pressure turbine is coupled to a vapor outlet of the flash evaporator. The throttling valve is coupled to a liquid outlet of the flash evaporator. The mixer is coupled to an outlet of the throttling valve and to an outlet of the high pressure turbine. The low pressure turbine is coupled to an outlet of the mixer. The condenser is coupled to an outlet of the low pressure turbine and to an inlet of the pump.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true How do I determine the outlet THC.../outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and add-on control... section to determine either the outlet THC emissions or add-on control device emission destruction or...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false How do I determine the outlet THC... Control Efficiency/outlet Concentration Option § 63.3555 How do I determine the outlet THC emissions and... methods in this section to determine either the outlet THC emissions or add-on control device emission...
Alcohol outlets and clusters of violence
2011-01-01
Background Alcohol related violence continues to be a major public health problem in the United States. In particular, there is substantial evidence of an association between alcohol outlets and assault. However, because the specific geographic relationships between alcohol outlets and the distribution of violence remains obscured, it is important to identify the spatial linkages that may exist, enhancing public health efforts to curb both violence and morbidity. Methods The present study utilizes police-recorded data on simple and aggravated assaults in Cincinnati, Ohio. Addresses of alcohol outlets for Cincinnati, including all bars, alcohol-serving restaurants, and off-premise liquor and convenience stores were obtained from the Ohio Division of Liquor Control and geocoded for analysis. A combination of proximity analysis, spatial cluster detection approaches and a geographic information system were used to identify clusters of alcohol outlets and the distribution of violence around them. Results A brief review of the empirical work relating to alcohol outlet density and violence is provided, noting that the majority of this literature is cross-sectional and ecological in nature, yielding a somewhat haphazard and aggregate view of how outlet type(s) and neighborhood characteristics like social organization and land use are related to assaultive violence. The results of the statistical analysis for Cincinnati suggest that while alcohol outlets are not problematic per se, assaultive violence has a propensity to cluster around agglomerations of alcohol outlets. This spatial relationship varies by distance and is also related to the characteristics of the alcohol outlet agglomeration. Specifically, spatially dense distributions of outlets appear to be more prone to clusters of assaultive violence when compared to agglomerations with a lower density of outlets. Conclusion With a more thorough understanding of the spatial relationships between alcohol outlets and the distribution of assaults, policymakers in urban areas can make more informed regulatory decisions regarding alcohol licenses. Further, this research suggests that public health officials and epidemiologists need to develop a better understanding of what actually occurs in and around alcohol outlets, determining what factors (whether outlet, neighborhood, or spatially related) help fuel their relationship with violence and other alcohol-related harm. PMID:21542932
Neighbourhood fast food outlets and obesity in children and adults: the CLAN Study.
Crawford, David A; Timperio, Anna F; Salmon, Jo A; Baur, Louise; Giles-Corti, Billie; Roberts, Rebecca J; Jackson, Michelle L; Andrianopoulos, Nick; Ball, Kylie
2008-01-01
We examined associations between density of and proximity to fast food outlets and body weight in a sample of children (137 aged 8-9 years and 243 aged 13-15 years) and their parents (322 fathers and 362 mothers). Children's measured and parents' self-reported heights and weights were used to calculate body mass index (BMI). Locations of major fast food outlets were geocoded. Bivariate linear regression analyses examined associations between the presence of any fast food outlet within a 2 km buffer around participants' homes, fast food outlet density within the 2 km buffer, and distance to the nearest outlet and BMI. Each independent variable was also entered into separate bivariate logistic regression analyses to predict the odds of being overweight or obese. Among older children, those with at least one outlet within 2 km had lower BMI z-scores. The further that fathers lived from an outlet, the higher their BMI. Among 13-15-year-old girls and their fathers, the likelihood of overweight/obesity was reduced by 80% and 50%, respectively, if they had at least one fast food outlet within 2 km of their home. Among older girls, the likelihood of being overweight/obese was reduced by 14% with each additional outlet within 2 km. Fathers' odds of being overweight/obese increased by 13% for each additional kilometre to the nearest outlet. While consumption of fast food has been shown to be associated with obesity, this study provides little support for the concept that exposure to fast food outlets in the local neighbourhood increases risk of obesity.
Underage purchasing of alcohol from packaged liquor outlets: an Australian study.
Rowland, Bosco C; Hall, Jessica K; Kremer, Peter J; Miller, Peter G; Toumbourou, John W
2017-10-01
Access to the supply of alcohol is an important factor influencing adolescent alcohol consumption. Although alcohol sales outlets are prohibited from selling alcohol to underage youth, there has been limited research investigating compliance. The present study sought to estimate the extent to which adolescents that appeared underage were successfully able to purchase alcohol from packaged liquor outlets in Australia; and to identify store and sales characteristics associated with illegal purchasing. In 2012, purchase surveys were conducted (n= 310) at packaged liquor outlets in 28 urban and rural communities across three states of Australia: Western Australia, Queensland and Victoria. Confederates successfully purchased alcohol at 60% (95% CI: 55-66) of outlets. The density of general alcohol outlets in the surrounding area and the type of liquor outlet were predictors of successful alcohol purchases; however, this was moderated by the state in which the purchase was made. Regional geographical location was also found to predict underage alcohol purchase. The majority of alcohol sales outlets in Australia breach regulations prohibiting sales to underage youth. Consistent enforcement of policies across the states of Australia, and reducing the number of alcohol outlets, will help prevent alcohol outlets illegally selling alcohol to underage adolescents. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M; Wright, Annie
2011-06-01
Environmental strategies to prevent the misuse of alcohol among youth--e.g., use of public policies to restrict minors' access to alcohol--have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings.
Chinman, Matthew; Burkhart, Q; Ebener, Patricia; Fan, Cha-Chi; Imm, Pamela; Osilla, Karen Chan; Paddock, Susan M.; Wright, Patricia Ann
2017-01-01
Environmental strategies to prevent the misuse of alcohol among youth—e.g., use of public policies to restrict minors’ access to alcohol—have been shown to reduce underage drinking. However, implementation of policy changes often requires public and private partnerships. One way to support these partnerships is to better understand the target of many of the environmental strategies, which is the alcohol sales outlet. Knowing more about how off-premises outlets (e.g., liquor and convenience stores) and on-premises outlets (e.g., bars and restaurants) are alike and different could help community-based organizations better tailor, plan, and implement their environmental strategies and strengthen partnerships between the public and commercial sectors. We conducted a survey of managerial or supervisory staff and/or owners of 336 off- and on-premises alcohol outlets in six counties in South Carolina, comparing these two outlet types on their preferences regarding certain alcohol sales practices, beliefs toward underage drinking, alcohol sales practices, and outcomes. Multilevel logistic regression showed that while off- and on-premises outlets did have many similarities, off-premises outlets appear to engage in more practices designed to prevent sales of alcohol to minors than on-premises outlets. The relationship between certain Responsible Beverage Service (RBS) practices and outcomes varied by outlet type. This study furthers the understanding of the differences between off- and on-premises alcohol sales outlets and offers options for increasing and tailoring environmental prevention efforts to specific settings. PMID:21373877
Perceptions of and Attitudes towards Ageing in Zambia
ERIC Educational Resources Information Center
Mapoma, Christopher C.; Masaiti, Gift
2012-01-01
This paper reflects part of the wider outlook on ageing in general in Zambia and was intended to investigate perceptions of and attitudes towards the aged and ageing in Zambia by members of the community who, by definition and chronologically are not classified as aged i.e. not yet 60 years and over. Focus Group Discussions (FGD) were used to…
USDA-ARS?s Scientific Manuscript database
Considerable amounts of flue gas desulfurization (FGD) gypsum are being produced as a by-product of generating electricity. As a result, beneficial reuse of this by-product is being sought to reduce landfilling and its associated cost. The use of this byproduct as a low-cost soil amendment for suppl...
Software Development for Decision Analysis
1975-03-01
to p Pollution Cost/lb Sulfur Emitted ( Flue Gas Desulfurization ) 178 3.11 Sensitivity of Total Societal Cost/KWH to...34 and "FGD ( flue gas desulfurization ) technology" have all been represented. The branching structure shown in Figure 3.7 (and for that matter each... Gas Desulfurization ) technol- ogy" are decision variables representing possible means of sulfur oxide emission control avallabie for the electric
Guide to Technical Documents. Volume 2. January 1983 through December 1983
1983-12-01
4) inclu- sion of the fluid-structural interaction. CR 80.023 Flue Gas Desulfurization at Navy Bases, Navy Energy Guidance...availability, costs, and operating performance of industrial-sized flue gas desulfurization (FGD) systems for coal-fired boilers was performed for...to close visual inspection. N-1658 Control Strategies for Reducing Heating, Ventilating, and Air Conditioning (HVAC) Energy Consumption in Single
2005-09-01
the Interior’s Bureau of Land Management (BLM). Flue - Gas Desulfurization (FGD). Post-combustion sulfur dioxide control technology in which a...8 (3) Special “transitional” classifications will be assigned to eligible areas participating in regional emission control strategies . b) Ozone...42 U.S.C. § 7411(f). C. States develop control strategies in their SIPs to achieve compliance with the NAAQS, but the federal government promulgates
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-19
... FGD Systems During Downtime as a Function of PSD,'' from Edward E. Reich to G.T. Helms and January 28... in the index, some information is not publicly available, e.g., CBI or other information whose... alternatives. g. Explain your views as clearly as possible, avoiding the use of profanity or personal threats...
16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, ...
16. VIEW OF HIGHLINE CANAL PIPELINE OUTLET, SHOWING THE OUTLET, A GROUNDWATER PUMP (LEFT), AND THE SOUTH BRANCH OF THE CANAL (FOREGROUND), August 1989 - Highline Canal & Pumping Station, South side of Salt River between Tempe, Phoenix & Mesa, Tempe, Maricopa County, AZ
6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET ...
6. VIEW OF OUTLET GATE WHEEL AND STEM, WITH OUTLET CHANNEL IN BACKGROUND, LOOKING SOUTHEAST - High Mountain Dams in Upalco Unit, Island Lake Dam, Ashley National Forest, 4.8 miles North of Miners Gulch Campground, Mountain Home, Duchesne County, UT
Out-of-home food outlets and area deprivation: case study in Glasgow, UK
Macintyre, Sally; McKay, Laura; Cummins, Steven; Burns, Cate
2005-01-01
Background There is a popular belief that out-of-home eating outlets, which typically serve energy dense food, may be more commonly found in more deprived areas and that this may contribute to higher rates of obesity and related diseases in such areas. Methods We obtained a list of all 1301 out-of-home eating outlets in Glasgow, UK, in 2003 and mapped these at unit postcode level. We categorised them into quintiles of area deprivation using the 2004 Scottish Index of Multiple Deprivation and computed mean density of types of outlet (restaurants, fast food restaurants, cafes and takeaways), and all types combined, per 1000 population. We also estimated odds ratios for the presence of any outlets in small areas within the quintiles. Results The density of outlets, and the likelihood of having any outlets, was highest in the second most affluent quintile (Q2) and lowest in the second most deprived quintile (Q4). Mean outlets per 1,000 were 4.02 in Q2, 1.20 in Q4 and 2.03 in Q5. With Q2 as the reference, Odds Ratios for having any outlets were 0.52 (CI 0.32–0.84) in Q1, 0.50 (CI 0.31 – 0.80) in Q4 and 0.61 (CI 0.38 – 0.98) in Q5. Outlets were located in the City Centre, West End, and along arterial roads. Conclusion In Glasgow those living in poorer areas are not more likely to be exposed to out-of-home eating outlets in their neighbourhoods. Health improvement policies need to be based on empirical evidence about the location of fast food outlets in specific national and local contexts, rather than on popular 'factoids'. PMID:16248898
Solution Conformations of Graphene Oxide Sheets, and Two-Dimensional Nanofluidics
NASA Astrophysics Data System (ADS)
Koltonow, Andrew R.
This work reports studies on the physical properties of collections of nanosheets. First, the configurations of graphene oxide sheets in solution are studied. Polarized optical microscopy reveals quickly and decisively that sheets remain flat and form lyotropic liquid crystals over a wide range of solvent conditions. When solvent conditions are inhospitable enough, sheets agglomerate into stacks rather crumpling upon themselves. Theory and simulation suggest that the crumpled state, which can be formed by compressing sheets, is metastable. This work might correct a persistent misunderstanding about the solution physics of graphene oxide. The other major area of study concerns the hydration layers in between lamellar stacks of exfoliated, restacked nanosheets. These layers comprise massive arrays of parallel two-dimensional nanofluidic channels, which exhibit enhanced unipolar ionic conductivity with counterions as the majority charge carriers. Based on the previously discovered graphene oxide nanofluidic platform, exfoliated vermiculite nanofluidic channels are constructed, which shuttle protons through the hydration channels by a Grotthuss mechanism, and which show superior thermal stability to graphene oxide. The 2D nanofluidics platform is also used to demonstrate "kirigami nanofluidics", where ion transport can be manipulated by cutting the film into specific shapes. This can give rise to ionic current rectification. The rectification effect is attributed to the size and shape mismatch of the concentration polarization zones developed at the inlets and outlets of the nanofluidic channels. The kirigami nanofluidic platform can be used to fabricate ionic diodes and other simple devices. This material platform is expected to be a useful tool for nanofluidics researchers, because it offers a way to carry out nanofluidic experiments quickly with minimal equipment and little expense.
Neighborhood deprivation and access to fast-food retailing: a national study.
Pearce, Jamie; Blakely, Tony; Witten, Karen; Bartie, Phil
2007-05-01
Obesogenic environments may be an important contextual explanation for the growing obesity epidemic, including its unequal social distribution. The objective of this study was to determine whether geographic access to fast-food outlets varied by neighborhood deprivation and school socioeconomic ranking, and whether any such associations differed to those for access to healthier food outlets. Data were collected on the location of fast-food outlets, supermarkets, and convenience stores across New Zealand. The data were geocoded and geographic information systems used to calculate travel distances from each census meshblock (i.e., neighborhood), and each school, to the closest fast-food outlet. Median travel distances are reported by a census-based index of socioeconomic deprivation for each neighborhood, and by a Ministry of Education measure of socioeconomic circumstances for each school. Analyses were repeated for outlets selling healthy food to allow comparisons. At the national level, statistically significant negative associations were found between neighborhood access to the nearest fast-food outlet and neighborhood deprivation (p<0.001) for both multinational fast-food outlets and locally operated outlets. The travel distances to both types of fast food outlet were at least twice as far in the least socially deprived neighborhoods compared to the most deprived neighborhoods. A similar pattern was found for outlets selling healthy food such as supermarkets and smaller food outlets (p<0.001). These relationships were broadly linear with travel distances tending to be shorter in more-deprived neighborhoods. There is a strong association between neighborhood deprivation and geographic access to fast food outlets in New Zealand, which may contribute to the understanding of environmental causes of obesity. However, outlets potentially selling healthy food (e.g., supermarkets) are patterned by deprivation in a similar way. These findings highlight the importance of considering all aspects of the food environment (healthy and unhealthy) when developing environmental strategies to address the obesity epidemic.
A longitudinal analysis of alcohol outlet density and assault.
Livingston, Michael
2008-06-01
The majority of studies that have examined the local-level relationship between alcohol outlet density and violence have utilized cross-sectional data. These studies have consistently demonstrated that there is a spatial link between outlets and violence, but because of their design they have not been able to determine whether changes in outlet density result in changes in rates of violence. The few studies that have examined this question over time have found that the violence rates are related to changes in outlet density. This study provides further evidence of this link and examines the characteristics of regions in which changes in outlet density are most strongly associated with changes in violence rates. The study examined 9 years of data measuring alcohol outlet density (using liquor licensing records) and alcohol-related violence (using police recorded night-time assaults) from 186 postcodes in the metropolitan area of Melbourne, Australia. The relationships between 3 types of alcohol outlet density and alcohol-related violence were assessed using fixed-effects models. The postcodes were then grouped into 5 clusters based on their socio-demographic profile and separate fixed-effects models were fitted to assess whether the relationships between outlets and violence differed based on the type of region being examined. The initial models found overall positive relationships between all 3 types of alcohol outlets and violence. When separate models were developed for postcode clusters, they demonstrated that the link between outlet density and violence was significant in all neighborhood types, but the specific relationships varied substantially. Changes in the number of alcohol outlets in a community are linked to changes in the amount of violence the community experiences. This relationship varies across the clusters of suburbs examined, with packaged liquor outlets consistently associated with violence in suburban areas and general (hotel) and on-premise (nightclubs, restaurants, and bars) licenses associated with violence in inner-city and inner-suburban areas.
Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C
2012-07-01
Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Cross-sectional study. 3293 students, aged 12 ± 0.6 years, randomly selected from eastern France middle schools. Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25-2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20-2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio-economically disadvantaged youth. These data should be relevant for influencing health policies and urban planning at both a national and local level.
40 CFR 86.884-8 - Dynamometer and engine equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...
40 CFR 86.884-8 - Dynamometer and engine equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...
40 CFR 86.884-8 - Dynamometer and engine equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...
40 CFR 86.884-8 - Dynamometer and engine equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
...), turbocharger outlet(s), exhaust aftertreatment device(s), or crossover junction (on Vee engines), whichever is... manifold, turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For... smoke levels 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust...
40 CFR 63.453 - Monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... outlet total HAP or methanol concentration, as an alternative to monitoring thermal oxidizer operating... operated to measure the methanol outlet concentration to comply with the steam stripper outlet... requirements specified in paragraphs (j)(1)(ii)(A) and (B) of this section. (A) Obtain daily inlet and outlet...
40 CFR 63.453 - Monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... outlet total HAP or methanol concentration, as an alternative to monitoring thermal oxidizer operating... operated to measure the methanol outlet concentration to comply with the steam stripper outlet... requirements specified in paragraphs (j)(1)(ii)(A) and (B) of this section. (A) Obtain daily inlet and outlet...
Roman, Caterina G; Reid, Shannon E
2012-01-01
Studies have consistently found a positive relationship between alcohol outlet density and assault, but only a handful of studies have examined whether outlet density has an influence on domestic violence. Using a framework based in crime opportunity theories, this study estimates spatial econometric regression models to test whether the density of alcohol outlets across neighborhoods is positively associated with police calls for service for domestic violence. Models also were developed to test whether the relationships found were consistent across time periods associated with the use of alcohol outlets (weeknights and weekends). The findings indicate that off-premise outlets were associated with a significant increase in domestic violence, but on-premise outlets (specifically restaurants and nightclubs) were associated with a decrease in domestic violence. The risk for domestic violence in areas of high densities of off-premise outlets was found to be high during the weekend but not during the weeknight, suggesting different routine activities for domestic violence offenders during the week.
40 CFR 86.884-8 - Dynamometer and engine equipment.
Code of Federal Regulations, 2014 CFR
2014-07-01
... appropriate type of smokemeter placed no more than 32 feet from the exhaust manifold(s), turbocharger outlet(s..., turbocharger outlet, or exhaust aftertreatment device, whichever is farthest downstream. (3) For engines with... 10 to 32 feet downstream from the exhaust manifold, turbocharger outlet, or exhaust aftertreatment...
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 193.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 76.15-25 - Discharge outlets.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Discharge outlets. 76.15-25 Section 76.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-25 Discharge outlets. (a) Discharge outlets shall...
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 95.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.15-25 Section 95.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-25 Discharge outlets. (a) Discharge outlets...
46 CFR 193.15-25 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Discharge outlets. 193.15-25 Section 193.15-25 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-25 Discharge outlets. (a) Discharge outlets...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aceves, Salvador M.; Ledesma-Orozco, Elias Rigoberto; Espinosa-Loza, Francisco
A pressure vessel apparatus for cryogenic capable storage of hydrogen or other cryogenic gases at high pressure includes an insert with a parallel inlet duct, a perpendicular inlet duct connected to the parallel inlet. The perpendicular inlet duct and the parallel inlet duct connect the interior cavity with the external components. The insert also includes a parallel outlet duct and a perpendicular outlet duct connected to the parallel outlet duct. The perpendicular outlet duct and the parallel outlet duct connect the interior cavity with the external components.
Community organization moderates the effect of alcohol outlet density on violence.
Pridemore, William Alex; Grubesic, Tony H
2012-12-01
There is growing evidence from multiple disciplines that alcohol outlet density is associated with community levels of assault. Based on the theoretical and empirical literatures on social organization and crime, we tested the hypothesis that the association between alcohol outlet density and neighbourhood violence rates is moderated by social organization. Using geocoded police data on assaults, geocoded data on the location of alcohol outlets, and controlling for several structural factors thought to be associated with violence rates, we tested this hypothesis employing negative binomial regression with our sample of 298 block groups in Cincinnati. Our results revealed direct effects of alcohol outlet density and social organization on assault density, and these effects held for different outlet types (i.e., off-premise, bars, restaurants) and levels of harm (i.e., simple and aggravated assaults). More importantly, we found that the strength of the outlet-assault association was significantly weaker in more socially organized communities. Subsequent analyses by level of organization revealed no effects of alcohol outlet density on aggravated assaults in organized block groups, but significant effects in disorganized block groups. We found no association between social (dis)organization and outlet density. These results clarify the community-level relationship between alcohol outlets and violence and have important implications for municipal-level alcohol policies. © London School of Economics and Political Science 2012.
Ecological Associations of Alcohol Outlets with Underage and Young Adult Injuries
Gruenewald, Paul J.; Freisthler, Bridget; Remer, Lillian; LaScala, Elizabeth A.; Treno, Andrew J.; Ponicki, William R.
2010-01-01
Objective This paper argues that associations between rates of three specific problems related to alcohol (i.e., accidents, traffic crashes, and assaults) should be differentially related to densities of off-premise outlets among underage youth and young adults based upon age related-patterns of alcohol outlet use. Methods Zip code-level population models assessed local and distal effects of alcohol outlets upon rates of hospital discharges for these outcomes. Results Densities of off-premise alcohol outlets were significantly related to injuries from accidents, assaults, and traffic crashes for both underage youth and young adults. Densities of bars were associated with more assaults and densities of restaurants were associated with more traffic crash injuries for young adults. Conclusions The distribution of alcohol-related injuries relative to alcohol outlets reflect patterns of alcohol outlet use. PMID:20028361
Freisthler, Bridget; Gaidus, Andrew; Tam, Christina; Ponicki, William R; Gruenewald, Paul J
2017-06-01
A movement from medical to recreational marijuana use allows for a larger base of potential users who have easier access to marijuana, because they do not have to visit a physician before using marijuana. This study examines whether changes in the density of marijuana outlets were related to violent, property, and marijuana-specific crimes in Denver, CO during a time in which marijuana outlets began selling marijuana for recreational, and not just medical, use. We collected data on locations of crimes, marijuana outlets and covariates for 481 Census block groups over 34 months (N = 16,354 space-time units). A Bayesian Poisson space-time model assessed statistical relationships between independent measures and crime counts within "local" Census block groups. We examined spatial "lag" effects to assess whether crimes in Census block groups adjacent to locations of outlets were also affected. Independent of the effects of covariates, densities of marijuana outlets were unrelated to property and violent crimes in local areas. However, the density of marijuana outlets in spatially adjacent areas was positively related to property crime in spatially adjacent areas over time. Further, the density of marijuana outlets in local and spatially adjacent blocks groups was related to higher rates of marijuana-specific crime. This study suggests that the effects of the availability of marijuana outlets on crime do not necessarily occur within the specific areas within which these outlets are located, but may occur in adjacent areas. Thus studies assessing the effects of these outlets in local areas alone may risk underestimating their true effects.
Alcohol beverage control, privatization and the geographic distribution of alcohol outlets
2012-01-01
Background With Pennsylvania currently considering a move away from an Alcohol Beverage Control state to a privatized alcohol distribution system, this study uses a spatial analytical approach to examine potential impacts of privatization on the number and spatial distribution of alcohol outlets in the city of Philadelphia over a long time horizon. Methods A suite of geospatial data were acquired for Philadelphia, including 1,964 alcohol outlet locations, 569,928 land parcels, and school, church, hospital, park and playground locations. These data were used as inputs for exploratory spatial analysis to estimate the expected number of outlets that would eventually operate in Philadelphia. Constraints included proximity restrictions (based on current ordinances regulating outlet distribution) of at least 200 feet between alcohol outlets and at least 300 feet between outlets and schools, churches, hospitals, parks and playgrounds. Results Findings suggest that current state policies on alcohol outlet distributions in Philadelphia are loosely enforced, with many areas exhibiting extremely high spatial densities of outlets that violate existing proximity restrictions. The spatial model indicates that an additional 1,115 outlets could open in Philadelphia if privatization was to occur and current proximity ordinances were maintained. Conclusions The study reveals that spatial analytical approaches can function as an excellent tool for contingency-based “what-if” analysis, providing an objective snapshot of potential policy outcomes prior to implementation. In this case, the likely outcome is a tremendous increase in alcohol outlets in Philadelphia, with concomitant negative health, crime and quality of life outcomes that accompany such an increase. PMID:23170899
49 CFR 178.337-8 - Openings, inlets, and outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...
49 CFR 178.337-8 - Openings, inlets, and outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... used to transport chlorine. The requirements for inlets and outlets on chlorine cargo tanks are in... dioxide, helium, krypton, neon, nitrogen, and xenon, or mixtures thereof. (6) In addition to the internal... equalization of pressure. (b) Inlets and discharge outlets on chlorine tanks. The inlet and discharge outlets...
46 CFR 76.17-20 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...
46 CFR 95.17-20 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...
46 CFR 95.17-20 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 95.17-20 Section 95.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 95.17-20 Discharge outlets. (a) Discharge outlets shall be...
46 CFR 76.17-20 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Discharge outlets. 76.17-20 Section 76.17-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Foam Extinguishing Systems, Details § 76.17-20 Discharge outlets. (a) Discharge outlets shall be of an...
ERIC Educational Resources Information Center
Wiggins, Lyna; Nower, Lia; Mayers, Raymond Sanchez; Peterson, N. Andrew
2010-01-01
This study examines the density of lottery outlets within ethnically concentrated neighborhoods in Middlesex County, New Jersey, using geospatial statistical analyses. No prior studies have empirically examined the relationship between lottery outlet density and population demographics. Results indicate that lottery outlets were not randomly…
Youth activity spaces and daily exposure to tobacco outlets.
Lipperman-Kreda, Sharon; Morrison, Christopher; Grube, Joel W; Gaidus, Andrew
2015-07-01
We explored whether exposure to tobacco outlets in youths' broader activity spaces differs from that obtained using traditional geographic measures of exposure to tobacco outlet within buffers around homes and schools. Youths completed an initial survey, daily text-prompted surveys, and carried GPS-enabled phones for one week. GPS locations were geocoded and activity spaces were constructed by joining sequential points. We calculated the number of tobacco outlets around these polylines and around homes and schools. Results suggest that activity spaces provide a more accurate measure of tobacco outlet exposures than traditional measures. Assessing tobacco outlet exposure within activity spaces may yield significant information to advance the field. Copyright © 2015 Elsevier Ltd. All rights reserved.
Richardson, E A; Hill, S E; Mitchell, R; Pearce, J; Shortt, N K
2015-05-01
Alcohol consumption may be influenced by the local alcohol retailing environment. This study is the first to examine neighbourhood alcohol outlet availability (on- and off-sales outlets) and alcohol-related health outcomes in Scotland. Alcohol-related hospitalisations and deaths were significantly higher in neighbourhoods with higher outlet densities, and off-sales outlets were more important than on-sales outlets. The relationships held for most age groups, including those under the legal minimum drinking age, although were not significant for the youngest legal drinkers (18-25 years). Alcohol-related deaths and hospitalisations were higher in more income-deprived neighbourhoods, and the gradient in deaths (but not hospitalisations) was marginally larger in neighbourhoods with higher off-sales outlet densities. Efforts to reduce alcohol-related harm should consider the potentially important role of the alcohol retail environment. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Transporting particulate material
Aldred, Derek Leslie [North Hollywood, CA; Rader, Jeffrey A [North Hollywood, CA; Saunders, Timothy W [North Hollywood, CA
2011-08-30
A material transporting system comprises a material transporting apparatus (100) including a material transporting apparatus hopper structure (200, 202), which comprises at least one rotary transporting apparatus; a stationary hub structure (900) constraining and assisting the at least one rotary transporting apparatus; an outlet duct configuration (700) configured to permit material to exit therefrom and comprising at least one diverging portion (702, 702'); an outlet abutment configuration (800) configured to direct material to the outlet duct configuration; an outlet valve assembly from the material transporting system venting the material transporting system; and a moving wall configuration in the material transporting apparatus capable of assisting the material transporting apparatus in transporting material in the material transporting system. Material can be moved from the material transporting apparatus hopper structure to the outlet duct configuration through the at least one rotary transporting apparatus, the outlet abutment configuration, and the outlet valve assembly.
Richardson, E.A.; Hill, S.E.; Mitchell, R.; Pearce, J.; Shortt, N.K.
2015-01-01
Alcohol consumption may be influenced by the local alcohol retailing environment. This study is the first to examine neighbourhood alcohol outlet availability (on- and off-sales outlets) and alcohol-related health outcomes in Scotland. Alcohol-related hospitalisations and deaths were significantly higher in neighbourhoods with higher outlet densities, and off-sales outlets were more important than on-sales outlets. The relationships held for most age groups, including those under the legal minimum drinking age, although were not significant for the youngest legal drinkers (18–25 years). Alcohol-related deaths and hospitalisations were higher in more income-deprived neighbourhoods, and the gradient in deaths (but not hospitalisations) was marginally larger in neighbourhoods with higher off-sales outlet densities. Efforts to reduce alcohol-related harm should consider the potentially important role of the alcohol retail environment. PMID:25840352
7 CFR 993.108 - Non-human consumption outlet.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., that any prunes or prune waste received for a non-human use will be used only within such outlet. [26... 7 Agriculture 8 2012-01-01 2012-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human...
7 CFR 993.108 - Non-human consumption outlet.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., that any prunes or prune waste received for a non-human use will be used only within such outlet. [26... 7 Agriculture 8 2014-01-01 2014-01-01 false Non-human consumption outlet. 993.108 Section 993.108... CALIFORNIA Administrative Rules and Regulations Definitions § 993.108 Non-human consumption outlet. Non-human...
The role of tobacco outlet density in a smoking cessation intervention for urban youth.
Mennis, Jeremy; Mason, Michael; Way, Thomas; Zaharakis, Nikola
2016-03-01
This study investigates the role of tobacco outlet density in a randomized controlled trial of a text messaging-based smoking cessation intervention conducted among a sample of 187 primarily African American youth in a midsize U.S. city. A moderated mediation model was used to test whether the indirect effect of residential tobacco outlet density on future smoking was mediated by the intention to smoke, and whether this indirect effect differed between adolescents who received the intervention and those who did not. Results indicated that tobacco outlet density is associated with intention to smoke, which predicts future smoking, and that the indirect effect of tobacco outlet density on future smoking is moderated by the intervention. Tobacco outlet density and the intervention can be viewed as competing forces on future smoking behavior, where higher tobacco outlet density acts to mitigate the sensitivity of an adolescent to the intervention's intended effect. Smoking cessation interventions applied to youth should consider tobacco outlet density as a contextual condition that can influence treatment outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Race, Ethnicity, and Exposure to Alcohol Outlets.
Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R
2016-01-01
Prior studies suggest that Black and Hispanic minority populations are exposed to greater concentrations of alcohol outlets, potentially contributing to health disparities between these populations and the White majority. We tested the alternative hypothesis that urban economic systems cause outlets to concentrate in low-income areas and, controlling for these effects, lower demand among minority populations leads to fewer outlets. Market potential for alcohol sales, a surrogate for demand, was estimated from survey and census data across census block groups for 50 California cities. Hierarchical Bayesian conditional autoregressive Poisson models then estimated relationships between observed geographic distributions of outlets and the market potential for alcohol, income, population size, and racial and ethnic composition. Market potentials were significantly smaller among lower income Black, Hispanic, and Asian populations. Block groups with greater market potential and lower income had greater concentrations of outlets. When we controlled for these effects, the racial and ethnic group composition of block groups was mostly unrelated to outlet concentrations. Health disparities related to exposure to alcohol outlets are primarily driven by distributions of income and population density across neighborhoods.
Race, Ethnicity, and Exposure to Alcohol Outlets
Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.
2016-01-01
Objective: Prior studies suggest that Black and Hispanic minority populations are exposed to greater concentrations of alcohol outlets, potentially contributing to health disparities between these populations and the White majority. We tested the alternative hypothesis that urban economic systems cause outlets to concentrate in low-income areas and, controlling for these effects, lower demand among minority populations leads to fewer outlets. Method: Market potential for alcohol sales, a surrogate for demand, was estimated from survey and census data across census block groups for 50 California cities. Hierarchical Bayesian conditional autoregressive Poisson models then estimated relationships between observed geographic distributions of outlets and the market potential for alcohol, income, population size, and racial and ethnic composition. Results: Market potentials were significantly smaller among lower income Black, Hispanic, and Asian populations. Block groups with greater market potential and lower income had greater concentrations of outlets. When we controlled for these effects, the racial and ethnic group composition of block groups was mostly unrelated to outlet concentrations. Conclusions: Health disparities related to exposure to alcohol outlets are primarily driven by distributions of income and population density across neighborhoods. PMID:26751356
D'Angelo, Heather; Fleischhacker, Sheila; Rose, Shyanika W; Ribisl, Kurt M
2014-07-01
Identifying tobacco retail outlets for U.S. FDA compliance checks or calculating tobacco outlet density is difficult in the 13 States without tobacco retail licensing or where licensing lists are unavailable for research. This study uses primary data collection to identify tobacco outlets in three counties in a non-licensing state and validate two commercial secondary data sources. We calculated sensitivity and positive predictive values (PPV) to examine the evidence of validity for two secondary data sources, and conducted a geospatial analysis to determine correct allocation to census tract. ReferenceUSA had almost perfect sensitivity (0.82) while Dun & Bradstreet (D&B) had substantial sensitivity (0.69) for identifying tobacco outlets; combined, sensitivity improved to 0.89. D&B identified fewer "false positives" with a PPV of 0.82 compared to 0.71 for ReferenceUSA. More than 90% of the outlets identified by ReferenceUSA were geocoded to the correct census tract. Combining two commercial data sources resulted in enumeration of nearly 90% of tobacco outlets in a three county area. Commercial databases appear to provide a reasonably accurate way to identify tobacco outlets for enforcement operations and density estimation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Socio-Spatial Patterning of Off-Sale and On-Sale Alcohol Outlets in a Texas City
Han, Daikwon; Gorman, Dennis M.
2014-01-01
Introduction and Aims To examine the socio-spatial patterning of off-sale and on-sale alcohol outlets following a policy change that ended prohibition of off-sale outlets in Lubbock, Texas. Design and Methods The spatial patterning of alcohol outlets by licensing type was examined using the k-function difference (D statistic) to compare the relative degree of spatial aggregation of the two types of alcohol outlets and by the spatial scan statistic to identify statistically significant geographic clusters of outlets. The sociodemographic characteristics of the areas containing clusters of outlets were compared to the rest of the city. In addition, the socioeconomic characteristics of census block groups with and without existing on-sale outlets were compared, as were the socioeconomic characteristics of census block groups with and without the newly issued off-sale licenses. Results The existing on-sale premises in Lubbock and the newly established off-sale premises introduced as a result of the 2009 policy change displayed different spatial patterns, with the latter being more spatially dispersed. A large cluster of on-sale outlets identified in the north-east of the city was located in a socially and economically disadvantaged area of the city. Discussion and Conclusion The findings support the view that it is important to understand the local context of deprivation within a city when examining the location of alcohol outlets and add to the existing research by drawing attention to the importance of geographic scale in assessing such relationships. PMID:24320205
Socio-spatial patterning of off-sale and on-sale alcohol outlets in a Texas city.
Han, Daikwon; Gorman, Dennis M
2014-03-01
To examine the socio-spatial patterning of off-sale and on-sale alcohol outlets following a policy change that ended prohibition of off-sale outlets in Lubbock, Texas. The spatial patterning of alcohol outlets by licensing type was examined using the k-function difference (D statistic) to compare the relative degree of spatial aggregation of the two types of alcohol outlets and by the spatial scan statistic to identify statistically significant geographic clusters of outlets. The sociodemographic characteristics of the areas containing clusters of outlets were compared with the rest of the city. In addition, the socioeconomic characteristics of census block groups with and without existing on-sale outlets were compared, as were the socioeconomic characteristics of census block groups with and without the newly issued off-sale licenses. The existing on-sale premises in Lubbock and the newly established off-sale premises introduced as a result of the 2009 policy change displayed different spatial patterns, with the latter being more spatially dispersed. A large cluster of on-sale outlets identified in the north-east of the city was located in a socially and economically disadvantaged area of the city. The findings support the view that it is important to understand the local context of deprivation within a city when examining the location of alcohol outlets and add to the existing research by drawing attention to the importance of geographic scale in assessing such relationships. © 2013 Australasian Professional Society on Alcohol and other Drugs.
Global Climate Change: Three Policy Perspectives
2008-11-26
example, the EPA spent approximately $2 billion supporting development of a feasible flue gas desulfurization (FGD) device for electric utility use to...Framework Convention on Climate Change, the United States committed to the objective of achieving “stabilization of greenhouse gas concentrations in...the United States would convene a meeting of the world’s “major economies” that are responsible for most greenhouse gas emissions. Held in September
JPRS Report, Science & Technology, China: Energy
1988-11-30
most electric power plants there have flue gas desulfuring (FGD) facilities, and 40 units (still in the design, demonstration program or experimental... control , the production of industrial substitute fuels (for petroleum and natural gas ) and other areas. The advanced character of new technologies, in...OIL, GAS Problems Facing Petroleum Industry Analyzed [Yang Wanli; JINGJI GUANLI, No 7, 1988] 64 Prospects for Petrochemical Industry in the 1990’s
Tobacco outlet density near home and school: Associations with smoking and norms among US teens
Schleicher, Nina C.; Johnson, Trent O.; Fortmann, Stephen P.; Henriksen, Lisa
2016-01-01
This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2,771, surveyed June 2011– December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant’s home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13–16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1,000 feet of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00,1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01,0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. PMID:27569829
Tobacco outlet density near home and school: Associations with smoking and norms among US teens.
Schleicher, Nina C; Johnson, Trent O; Fortmann, Stephen P; Henriksen, Lisa
2016-10-01
This study examined whether living or going to school in neighborhoods with higher tobacco outlet density is associated with higher odds of cigarette smoking among teens, and with perceptions of greater smoking prevalence and peer approval. Using an Internet panel that is representative of US households, we matched data from teen-parent pairs (n=2771, surveyed June 2011-December 2012) with environmental data about home and school neighborhoods. Density was measured as the number of tobacco outlets per square mile for a ½-mile roadway service area around each participant's home and school. Logistic regressions tested relationships between tobacco outlet density near home and schools with ever smoking. Linear regressions tested relationships between density, perceived prevalence and peer approval. Models were adjusted for teen, parent/household and neighborhood characteristics. In total, 41.0% of US teens (ages 13-16) lived within ½ mile of a tobacco outlet, and 44.4% attended school within 1000ft of a tobacco outlet. Higher tobacco outlet density near home was associated with higher odds of ever smoking, although the relationship was small, OR=1.01, 95% CI (1.00, 1.02). Higher tobacco outlet density near home was also associated with perceptions that more adults smoked, coef.=0.09, 95% CI (0.01, 0.17). Higher tobacco outlet density near schools was not associated with any outcomes. Living in neighborhoods with higher tobacco outlet density may contribute to teen smoking by increasing access to tobacco products and by cultivating perceptions that smoking is more prevalent. Policy interventions to restrict tobacco outlet density should not be limited to school environments. Copyright © 2016 Elsevier Inc. All rights reserved.
Reash, Robin J; Brown, Lauren; Merritt, Karen
2015-07-01
Many coal-fired electric generating facilities in the United States are discharging higher loads of Hg, Se, and other chemicals to receiving streams due to the installation of flue gas desulfurization (FGD) air pollution control units. There are regulatory concerns about the potential increased uptake of these bioaccumulative trace elements into food webs. We evaluated the concentrations of As, total Hg (THg), methylmercury (MeHg), and Se in Ohio River fish collected proximal to coal-fired power plants, of which 75% operate FGD systems. Fillet samples (n = 50) from 6 fish species representing 3 trophic levels were analyzed. Geometric mean fillet concentrations of THg (wet wt), MeHg (wet wt), and Se (dry wt) in 3 species were 0.136, 0.1181, and 3.19 mg/kg (sauger); 0.123, 0.1013, and 1.56 mg/kg (channel catfish); and 0.127, 0.0914, and 3.30 mg/kg (hybrid striped bass). For all species analyzed, only 3 fillet samples (6% of total) had MeHg concentrations that exceeded the US Environmental Protection Agency (USEPA) human health criterion (0.3 mg/kg wet wt); all of these were freshwater drum aged ≥ 19 y. None of the samples analyzed exceeded the USEPA proposed muscle and whole body Se thresholds for protection against reproductive effects in freshwater fish. All but 8 fillet samples had a total As concentration less than 1.0 mg/kg dry wt. Mean Se health benefit values (HBVSe ) for all species were ≥ 4, indicating that potential Hg-related health risks associated with consumption of Ohio River fish are likely to be offset by adequate Se concentrations. Overall, we observed no measurable evidence of enhanced trace element bioaccumulation associated with proximity to power plant FGD facilities, however, some enhanced bioaccumulation could have occurred in the wastewater mixing zones. Furthermore, available evidence indicates that, due to hydraulic and physical factors, the main stem Ohio River appears to have low net Hg methylation potential. © 2015 SETAC.
Strategy for integration of coastal culture in learning process of mathematics in junior high school
NASA Astrophysics Data System (ADS)
Suyitno, H.; Zaenuri; Florentinus, T. S.; Zakaria, E.
2018-03-01
Traditional life in the fishing family is part of the local culture. Many School-age children in the fishing family drop-outs due to lack of parents motivation and the environment was less supportive. The problems were: (1) How the strategy of integration of local culture in learning process of mathematics in Junior High School (JHS)? (2) How to prepare the Mathematics Student’s Book for grade 7 of JHS that based on coastal culture, that has an ISBN, has international level, applicable, and in accordance with the current curriculum? The purposes of this research were: (1) to obtain the strategy of integration of local culture in learning process of mathematics in JHS, through FGD between UNNES and UKM; (2) to obtain the experts validation, through Focus Group Discussion (FGD) between UNNES and UKM toward the draft of the Mathematics Student’s Book for grade 7 of JHS that based on coastal culture; (3) produces Mathematics Student’s Book for grade 7 SMP which based on coastal culture and has an ISBN, international, applicable, and in accordance with the curriculum. The research activity was a qualitative research, so that the research methods include: (1) data reduction, (2) display data, (3) data interpretation, and (4) conclusion/verification. The main activities of this research: drafting the Mathematics Student’s Book of Grade 7 which based on coastal culture; get the validation from international partners;conducting FGD at Education Faculty of Universiti Kebangsaan Malaysia through the program of visiting lecturers for getting the Mathematics Student’s Book of grade 7 which based on coastal culture, registering for ISBN, and publishing the reasearch results in International seminar and International Journals. The results of this research were as follows. (1) Getting a good strategy for integration of local culture in learning process of mathematics in JHS. (2) Getting the Mathematics Student’s Book for grade 7 of JHS that based on coastal culture, that has an ISBN, international level, applicable, and in accordance with the current curriculum.
Hobday, Michelle; Chikritzhs, Tanya; Liang, Wenbin; Meuleners, Lynn
2015-12-01
Few studies have investigated the combined effects of alcohol sales, outlet numbers and trading hours on alcohol-related harms. This study aimed to test whether associations: (i) exist between alcohol-related emergency department (ED) injuries and alcohol sales and counts of outlets; (ii) vary between on- and off-premises outlets; and (iii) vary by trading hours conditions [extended trading permits (ETP) versus standard hours]. Panel study using 117 postcodes over 8 years (2002-10): 936 data points. Perth, Australia. ED injury presentations, aggregated to postcode-level. Alcohol-related injuries were identified using time-based surrogate measures: night injuries (n=51,241) and weekend night injuries (n=30,682). Measures of alcohol availability included number of outlets with standard and extended trading hours and mean sales per postcode. Negative binomial regression modelling with random effects was used to examine associations between availability and alcohol-related injury, controlling for socio-demographic characteristics. (i) Night injuries were associated significantly with counts of on-premises outlets [incident rate ratio (IRR)=1.046; 95% confidence interval (CI)=1.014-1.078] and sales per off-premises outlet (IRR=1.019; 95% CI=1.004-1.035); (ii) counts of on-premises outlets were positively associated with alcohol-related injury while counts of off-premises outlets indicated a negative association; and (iii) weekend night injuries increased by about 5% per on-premises outlet with an ETP (IRR=1.049; 95% CI=1.015-1.084) and by less than 1% for outlets with standard trading hours (IRR=1.008; 95% CI=1.004-1.013). Regions of Perth, Australia with greater off-premises alcohol sales and counts of on-premises alcohol outlets, particularly those with extended trading hours, appear to have higher levels of alcohol-related injuries. © 2015 Society for the Study of Addiction.
Obesity-promoting food environments and the spatial clustering of food outlets around schools.
Day, Peter L; Pearce, Jamie
2011-02-01
The increasing prevalence of overweight and obesity in school-aged children is potentially linked to contextual influences such as the food environment around schools. The proximity of fast-food and convenience stores to schools may enhance access to unhealthy foods and have a negative impact on diet. This study used spatial cluster analysis to determine whether food outlets are clustered around schools and evaluated the extent of food outlet clustering by school and school neighborhood sociodemographic characteristics. The locations in 2008 of all schools, fast-food outlets, and convenience stores in five urban regions across New Zealand were geocoded. Using GIS analysis conducted in 2009, the number and proportion of outlets within 400-m and 800-m road distance around each school was calculated. The spatial clustering of food outlets within 1.5 km of schools was determined using a multi-type K-function. Food outlet type, school level, SES, the degree of population density, and commercial land use zoning around each school were compared. Primary/intermediate schools had a total proportion of 19.3 outlets per 1000 students within 800 m compared to 6.6 for secondary schools. The most socially deprived quintile of schools had three times the number and proportion of food outlets compared to the least-deprived quintile. There was a high degree of clustering of food outlets around schools, with up to 5.5 times more outlets than might be expected. Outlets were most clustered up to 800 m from schools and around secondary schools, socially deprived schools, and schools in densely populated and commercially zoned areas. Food environments in New Zealand within walking proximity to schools are characterized by a high density of fast-food outlets and convenience stores, particularly in more-socially deprived settings. These obesogenic environments provide ready access to obesity-promoting foods that may have a negative impact on student diet and contribute to inequalities in health. Copyright © 2011 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.
Casey, R; Chaix, B; Weber, C; Schweitzer, B; Charreire, H; Salze, P; Badariotti, D; Banos, A; Oppert, J-M; Simon, C
2012-01-01
Objective: Some characteristics of the built environment have been associated with obesity in youth. Our aim was to determine whether individual and environmental socio-economic characteristics modulate the relation between youth overweight and spatial accessibility to physical activity (PA) facilities and to food outlets. Design: Cross-sectional study. Subjects: 3293 students, aged 12±0.6 years, randomly selected from eastern France middle schools. Measurements and methods: Using geographical information systems (GIS), spatial accessibility to PA facilities (urban and nature) was assessed using the distance to PA facilities at the municipality level; spatial accessibility to food outlets (general food outlets, bakeries and fast-food outlets) was calculated at individual level using the student home address and the food outlets addresses. Relations of weight status with spatial accessibility to PA facilities and to food outlets were analysed using mixed logistic models, testing potential direct and interaction effects of individual and environmental socio-economic characteristics. Results: Individual socio-economic status modulated the relation between spatial accessibility to PA facilities and to general food outlets and overweight. The likelihood of being overweight was higher when spatial accessibility to urban PA facilities and to general food outlets was low, but in children of blue-collar-workers only. The odds ratio (OR) (95% confidence interval) for being overweight of blue-collar-workers children compared with non-blue-collar-workers children was 1.76 (1.25–2.49) when spatial accessibility to urban PA facilities was low. This OR was 1.86 (1.20–2.86) when spatial accessibility to general food outlets was low. There was no significant relationship of overweight with either nature PA facilities or other food outlets (bakeries and fast-food outlets). Conclusion: These results indicate that disparities in spatial accessibility to PA facilities and to general food outlets may amplify the risk of overweight in socio-economically disadvantaged youth. These data should be relevant for influencing health policies and urban planning at both a national and local level. PMID:22310474
Holmes, John; Green, Mark; Strong, Mark; Pearson, Tim; Meier, Petra
2016-01-01
Background Availability of alcohol is a major policy issue for governments, and one of the availability factors is the density of alcohol outlets within geographic areas. Objective The aim of this study is to investigate the association between alcohol outlet density and hospital admissions for alcohol-related conditions in a national (English) small area level ecological study. Methods This project will employ ecological correlation and cross-sectional time series study designs to examine spatial and temporal relationships between alcohol outlet density and hospital admissions. Census units to be used in the analysis will include all Lower and Middle Super-Output Areas (LSOAs and MSOAs) in England (53 million total population; 32,482 LSOAs and 6781 MSOAs). LSOAs (approximately 1500 people per LSOA) will support investigation at a fine spatial resolution. Spatio-temporal associations will be investigated using MSOAs (approximately 7500 people per MSOA). The project will use comprehensive coverage data on alcohol outlets in England (from 2003, 2007, 2010, and 2013) from a commercial source, which has estimated that the database includes 98% of all alcohol outlets in England. Alcohol outlets may be classified into two broad groups: on-trade outlets, comprising outlets from which alcohol can be purchased and consumed on the premises (eg, pubs); and off-trade outlets, in which alcohol can be purchased but not consumed on the premises (eg, off-licenses). In the 2010 dataset, there are 132,989 on-trade and 51,975 off-trade outlets. The longitudinal data series will allow us to examine associations between changes in outlet density and changes in hospital admission rates. The project will use anonymized data on alcohol-related hospital admissions in England from 2003 to 2013 and investigate associations with acute (eg, admissions for injuries) and chronic (eg, admissions for alcoholic liver disease) harms. The investigation will include the examination of conditions that are wholly and partially attributable to alcohol, using internationally standardized alcohol-attributable fractions. Results The project is currently in progress. Results are expected in 2017. Conclusions The results of this study will provide a national evidence base to inform policy decisions regarding the licensing of alcohol sales outlets. PMID:27986646
Wilkins, Emma L; Radley, Duncan; Morris, Michelle A; Griffiths, Claire
2017-12-20
Secondary data containing the locations of food outlets is increasingly used in nutrition and obesity research and policy. However, evidence evaluating these data is limited. This study validates two sources of secondary food environment data: Ordnance Survey Points of Interest data (POI) and food hygiene data from the Food Standards Agency (FSA), against street audits in England and appraises the utility of these data. Audits were conducted across 52 Lower Super Output Areas in England. All streets within each Lower Super Output Area were covered to identify the name and street address of all food outlets therein. Audit-identified outlets were matched to outlets in the POI and FSA data to identify true positives (TP: outlets in both the audits and the POI/FSA data), false positives (FP: outlets in the POI/FSA data only) and false negatives (FN: outlets in the audits only). Agreement was assessed using positive predictive values (PPV: TP/(TP + FP)) and sensitivities (TP/(TP + FN)). Variations in sensitivities and PPVs across environment and outlet types were assessed using multi-level logistic regression. Proprietary classifications within the POI data were additionally used to classify outlets, and agreement between audit-derived and POI-derived classifications was assessed. Street audits identified 1172 outlets, compared to 1100 and 1082 for POI and FSA respectively. PPVs were statistically significantly higher for FSA (0.91, CI: 0.89-0.93) than for POI (0.86, CI: 0.84-0.88). However, sensitivity values were not different between the two datasets. Sensitivity and PPVs varied across outlet types for both datasets. Without accounting for this, POI had statistically significantly better PPVs in rural and affluent areas. After accounting for variability across outlet types, FSA had statistically significantly better sensitivity in rural areas and worse sensitivity in rural middle affluence areas (relative to deprived). Audit-derived and POI-derived classifications exhibited substantial agreement (p < 0.001; Kappa = 0.66, CI: 0.63-0.70). POI and FSA data have good agreement with street audits; although both datasets had geographic biases which may need to be accounted for in analyses. Use of POI proprietary classifications is an accurate method for classifying outlets, providing time savings compared to manual classification of outlets.
12 CFR 7.1014 - Sale of money orders at nonbanking outlets.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 1 2011-01-01 2011-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...
12 CFR 7.1014 - Sale of money orders at nonbanking outlets.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 12 Banks and Banking 1 2012-01-01 2012-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...
12 CFR 7.1014 - Sale of money orders at nonbanking outlets.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 12 Banks and Banking 1 2014-01-01 2014-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...
12 CFR 7.1014 - Sale of money orders at nonbanking outlets.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 12 Banks and Banking 1 2013-01-01 2013-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...
12 CFR 7.1014 - Sale of money orders at nonbanking outlets.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Sale of money orders at nonbanking outlets. 7... ACTIVITIES AND OPERATIONS Bank Powers § 7.1014 Sale of money orders at nonbanking outlets. A national bank may designate bonded agents to sell the bank's money orders at nonbanking outlets. The responsibility...
49 CFR 179.220-18 - Bottom outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Specifications for Non-Pressure Tank Car Tanks (Classes DOT-111AW and 115AW) § 179.220-18 Bottom outlets. (a) The... equivalent, except that bottom outlet closure plugs may be attached by 1/4-inch chain. When the bottom outlet... valve body may be steam jacketed, in which case the breakage groove or its equivalent must be below the...
Bharathan, Desikan [Lakewood, CO; Hassani, Vahab [Golden, CO
2008-05-20
A stratified vapor generator (110) comprises a first heating section (H.sub.1) and a second heating section (H.sub.2). The first and second heating sections (H.sub.1, H.sub.2) are arranged so that the inlet of the second heating section (H.sub.2) is operatively associated with the outlet of the first heating section (H.sub.1). A moisture separator (126) having a vapor outlet (164) and a liquid outlet (144) is operatively associated with the outlet (124) of the second heating section (H.sub.2). A cooling section (C.sub.1) is operatively associated with the liquid outlet (144) of the moisture separator (126) and includes an outlet that is operatively associated with the inlet of the second heating section (H.sub.2).
Angus, Colin; Holmes, John; Maheswaran, Ravi; Green, Mark A; Meier, Petra; Brennan, Alan
2017-04-12
Much literature examines the relationship between the spatial availability of alcohol and alcohol-related harm. This study aims to address an important gap in this evidence by using detailed outlet data to examine recent temporal trends in the sociodemographic distribution of spatial availability for different types of alcohol outlet in England. Descriptive analysis of measures of alcohol outlet density and proximity using extremely high resolution market research data stratified by outlet type and quintiles of area-level deprivation from 2003, 2007, 2010 and 2013 was undertaken and hierarchical linear growth models fitted to explore the significance of socioeconomic differences. We find that overall availability of alcohol changed very little from 2003 to 2013 (density +1.6%), but this conceals conflicting trends by outlet type and area-level deprivation. Mean on-trade density has decreased substantially (-2.2 outlets within 1 km (Inter-Quartile Range (IQR) -3-0), although access to restaurants has increased (+1.0 outlets (IQR 0-1)), while off-trade access has risen substantially (+2.4 outlets (IQR 0-3)). Availability is highest in the most deprived areas ( p < 0.0001) although these areas have also seen the greatest falls in on-trade outlet availability ( p < 0.0001). This study underlines the importance of using detailed, low-level geographic data to understand patterns and trends in the spatial availability of alcohol. There are significant variations in these trends by outlet type and deprivation level which may have important implications for health inequalities and public health policy.
Mayo, Mariel Leah; Pitts, Stephanie B Jilcott; Chriqui, Jamie F
2013-12-05
Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents' attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents' access to fruit and vegetable outlets in rural northeastern North Carolina. From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities.
Angus, Colin; Holmes, John; Maheswaran, Ravi; Green, Mark A.; Meier, Petra; Brennan, Alan
2017-01-01
Much literature examines the relationship between the spatial availability of alcohol and alcohol-related harm. This study aims to address an important gap in this evidence by using detailed outlet data to examine recent temporal trends in the sociodemographic distribution of spatial availability for different types of alcohol outlet in England. Descriptive analysis of measures of alcohol outlet density and proximity using extremely high resolution market research data stratified by outlet type and quintiles of area-level deprivation from 2003, 2007, 2010 and 2013 was undertaken and hierarchical linear growth models fitted to explore the significance of socioeconomic differences. We find that overall availability of alcohol changed very little from 2003 to 2013 (density +1.6%), but this conceals conflicting trends by outlet type and area-level deprivation. Mean on-trade density has decreased substantially (−2.2 outlets within 1 km (Inter-Quartile Range (IQR) −3–0), although access to restaurants has increased (+1.0 outlets (IQR 0–1)), while off-trade access has risen substantially (+2.4 outlets (IQR 0–3)). Availability is highest in the most deprived areas (p < 0.0001) although these areas have also seen the greatest falls in on-trade outlet availability (p < 0.0001). This study underlines the importance of using detailed, low-level geographic data to understand patterns and trends in the spatial availability of alcohol. There are significant variations in these trends by outlet type and deprivation level which may have important implications for health inequalities and public health policy. PMID:28417941
Mayo, Mariel Leah; Chriqui, Jamie F.
2013-01-01
Introduction Zoning ordinances and land-use plans may influence the community food environment by determining placement and access to food outlets, which subsequently support or hinder residents’ attempts to eat healthfully. The objective of this study was to examine associations between healthful food zoning scores as derived from information on local zoning ordinances, county demographics, and residents’ access to fruit and vegetable outlets in rural northeastern North Carolina. Methods From November 2012 through March 2013, county and municipality zoning ordinances were identified and double-coded by using the Bridging the Gap food code/policy audit form. A healthful food zoning score was derived by assigning points for the allowed use of fruit and vegetable outlets. Pearson coefficients were calculated to examine correlations between the healthful food zoning score, county demographics, and the number of fruit and vegetable outlets. In March and April 2013, qualitative interviews were conducted among county and municipal staff members knowledgeable about local zoning and planning to ascertain implementation and enforcement of zoning to support fruit and vegetable outlets. Results We found a strong positive correlation between healthful food zoning scores and the number of fruit and vegetable outlets in 13 northeastern North Carolina counties (r = 0.66, P = .01). Major themes in implementation and enforcement of zoning to support fruit and vegetable outlets included strict enforcement versus lack of enforcement of zoning regulations. Conclusion Increasing the range of permitted uses in zoning districts to include fruit and vegetable outlets may increase access to healthful fruit and vegetable outlets in rural communities. PMID:24309091
Socioeconomic area disparities in tobacco retail outlet density: a Western Australian analysis.
Wood, Lisa J; Pereira, Gavin; Middleton, Nick; Foster, Sarah
2013-05-20
To examine the association between tobacco outlet density and area socioeconomic status (SES) in Western Australia. Ecological cross-sectional study investigating the relationship between the area SES of, and the density of tobacco retail outlets in, WA suburbs and towns for the Perth metropolitan area, and at the regional and state level. SES was determined using the 2006 Australian Bureau of Statistics Index of Relative Socioeconomic Advantage and Disadvantage (IRSAD) and classified into quartiles (very low, low, high and very high); tobacco outlet data were sourced from the WA Department of Health register of retailers licensed to sell tobacco at May 2011. Tobacco outlet density rate (per 10 000 residents). In WA overall, suburbs and towns with a very low IRSAD had more than four times the number of tobacco outlets compared with those with a very high IRSAD (P> < 0.001). This trend was similar when analyses were restricted to the Perth metropolitan area and to regional areas. Suburbs and towns in regional WA with a very low IRSAD had more than five times the number of tobacco outlets than those with a very high IRSAD (P> < 0.001). This study provides the first Australian evidence of a strong relationship between area SES and tobacco outlet density. Findings are consistent with a number of United States studies that report higher tobacco outlet densities in lower SES or minority neighbourhoods. The results underscore the importance of policy approaches to limit the number of tobacco retail licences granted, and to reduce the geographic density of outlets in more disadvantaged suburbs and towns.
Tobacco Retail Outlets and Vulnerable Populations in Ontario, Canada
Chaiton, Michael O.; Mecredy, Graham C.; Cohen, Joanna E.; Tilson, Melodie L.
2013-01-01
Interest has been increasing in regulating the location and number of tobacco vendors as part of a comprehensive tobacco control program. The objective of this paper is to examine the distribution of tobacco outlets in a large jurisdiction, to assess: (1) whether tobacco outlets are more likely to be located in vulnerable areas; and (2) what proportion of tobacco outlets are located close to schools. Retail locations across the Province of Ontario from Ministry of Health Promotion data were linked to 2006 Census data at the neighbourhood level. There was one tobacco retail outlet for every 1,000 people over age 15 in Ontario. Density of outlets varied by public health unit, and was associated with the number of smokers. Tobacco outlets were more likely to be located in areas that had high neighbourhood deprivation, in both rural and urban areas. Outlets were less likely to be located in areas with high immigrant populations in urban areas, with the reverse being true for rural areas. Overall, 65% of tobacco retailers were located within 500 m of a school. The sale of tobacco products is ubiquitous, however, neighbourhoods with lower socio-economic status are more likely to have easier availability of tobacco products and most retailers are located within walking distance of a school. The results suggest the importance of policies to regulate the location of tobacco retail outlets. PMID:24351748
Astudillo, Mariana; Kuendig, Hervé; Centeno-Gil, Adriana; Wicki, Matthias; Gmel, Gerhard
2014-09-01
This study investigated the associations of alcohol outlet density with specific alcohol outcomes (consumption and consequences) among young men in Switzerland and assessed the possible geographically related variations. Alcohol consumption and drinking consequences were measured in a 2010-2011 study assessing substance use risk factors (Cohort Study on Substance Use Risk Factors) among 5519 young Swiss men. Outlet density was based on the number of on- and off-premise outlets in the district of residence. Linear regression models were run separately for drinking level, heavy episodic drinking (HED) and drinking consequences. Geographically weighted regression models were estimated when variations were recorded at the district level. No consistent association was found between outlet density and drinking consequences. A positive association between drinking level and HED with on-premise outlet density was found. Geographically weighted regressions were run for drinking level and HED. The predicted values for HED were higher in the southwest part of Switzerland (French-speaking part). Among Swiss young men, the density of outlets and, in particular, the abundance of bars, clubs and other on-premise outlets was associated with drinking level and HED, even when drinking consequences were not significantly affected. These findings support the idea that outlet density needs to be considered when developing and implementing regional-based prevention initiatives. © 2014 Australasian Professional Society on Alcohol and other Drugs.
Isolated colonic inertia is not usually the cause of chronic constipation.
Ragg, J; McDonald, R; Hompes, R; Jones, O M; Cunningham, C; Lindsey, I
2011-11-01
Chronic constipation is classified as outlet obstruction, colonic inertia or both. We aimed to determine the incidence of isolated colonic inertia in chronic constipation and to study symptom pattern in those with prolonged colonic transit time. Chronic constipation patients were classified radiologically by surgeon-reported defaecating proctography and transit study into four groups: isolated outlet obstruction, isolated colonic inertia, outlet obstruction plus colonic inertia, or normal. Symptom patterns were defined as stool infrequency (twice weekly or less) or frequent unsuccessful evacuations (more than twice weekly). Of 541 patients with chronic constipation, 289 (53%) were classified as isolated outlet obstruction, 26 (5%) as isolated colonic inertia, 159 (29%) as outlet obstruction plus colonic inertia and 67 (12%) as normal. Of 448 patients (83%) with outlet obstruction, 35% had additional colonic inertia. Only 14% of those with prolonged colonic transit time had isolated colonic inertia. Frequent unsuccessful evacuations rather than stool infrequency was the commonest symptom pattern in all three disease groups (isolated outlet obstruction 86%, isolated colonic inertia 54% and outlet obstruction plus colonic inertia 63%). Isolated colonic inertia is an unusual cause of chronic constipation. Most patients with colonic inertia have associated outlet obstruction. These data question the clinical significance of isolated colonic inertia. © 2011 The Authors. Colorectal Disease © 2011 The Association of Coloproctology of Great Britain and Ireland.
Community Alcohol Outlet Density and Underage Drinking
Chen, Meng-Jinn; Grube, Joel W.; Gruenewald, Paul J.
2009-01-01
Aim This study examined how community alcohol outlet density may be associated with drinking among youths. Methods Longitudinal data were collected from 1091 adolescents (aged 14–16 at baseline) recruited from 50 zip codes in California with varying levels of alcohol outlet density and median household income. Hierarchical linear models were used to examine the associations between zip code alcohol outlet density and frequency rates of general alcohol use and excessive drinking, taking into account zip code median household income and individual-level variables (age, gender, race/ethnicity, personal income, mobility, and perceived drinking by parents and peers). Findings When all other factors were controlled, higher initial levels of drinking and excessive drinking were observed among youths residing in zip codes with higher alcohol outlet densities. Growth in drinking and excessive drinking was on average more rapid in zip codes with lower alcohol outlet densities. The relation of zip code alcohol outlet density with drinking appeared to be mitigated by having friends with access to a car. Conclusion Alcohol outlet density may play a significant role in initiation of underage drinking during early teen ages, especially when youths have limited mobility. Youth who reside in areas with low alcohol outlet density may overcome geographic constraints through social networks that increase their mobility and the ability to seek alcohol and drinking opportunities beyond the local community. PMID:20078485
16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...
16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...
16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...
16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...
16 CFR Appendix D to Part 436 - Sample Item 20(3) Table-Status of Franchise Outlets
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Sample Item 20(3) Table-Status of Franchise Outlets D Appendix D to Part 436 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES... Item 20(3) Table—Status of Franchise Outlets Status of Franchise Outlets For years 2004 to 2006 Column...
46 CFR 153.352 - B/3 and 4 m venting system outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...
46 CFR 153.352 - B/3 and 4 m venting system outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false B/3 and 4 m venting system outlets. 153.352 Section 153.352 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES... Cargo Venting Systems § 153.352 B/3 and 4 m venting system outlets. A B/3 or 4 m venting system outlet...
Electrically heated particulate matter filter with recessed inlet end plugs
Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI
2012-02-21
A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.
Rutta, E; Tarimo, A; Delmotte, E; James, I; Mwakisu, S; Kasembe, D; Konduri, N; Silumbe, R; Kakanda, K; Valimba, R
2014-09-01
Private sector accredited drug dispensing outlets in Morogoro and pharmacies in Dar es Salaam, Tanzania. To assess 1) the level of knowledge about tuberculosis (TB) among dispensers in Tanzania's retail pharmaceutical sector; 2) practices related to identification of patients with suspected TB; 3) the availability of educational materials and training; and 4) the availability of first- and second-line anti-tuberculosis treatment in retail drug outlets. A cross-sectional descriptive study involving the administration of a structured questionnaire among drug dispensers in 122 pharmacies and 173 accredited drug dispensing outlets. Private retail drug outlets are convenient; most are open at least 12 h per day, 7 days/week. Although 95% of dispensers identified persistent cough as a symptom of TB, only 1% had received TB-related training in the previous 3 years; 8% of outlets stocked first-line anti-tuberculosis medicines, which are legally prohibited from being sold at retail outlets. The majority of respondents reported seeing clients with TB-like symptoms, and of these 95% reported frequently referring clients to nearby health facilities. Private retail pharmaceutical outlets can potentially contribute to TB case detection and treatment; however, a coordinated effort is needed to train dispensers and implement appropriate referral procedures.
49 CFR 178.345-11 - Tank outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... unloading of lading, as distinguished from outlets such as manhole covers, vents, vapor recovery devices... away from the loading/unloading outlet. The actuating mechanism must be corrosion-resistant and...
NASA Technical Reports Server (NTRS)
Symons, E. P.
1979-01-01
An analysis is presented for defining the outlet contour of a hemispherical-bottomed cylindrical tank that will prevent vapor ingestion when the tank is drained. The analysis was used to design two small-scale tanks that were fabricated and then tested in a low gravity environment. The draining performance of the tanks was compared with that for a tank with a conventional outlet having a constant circular cross-sectional area, under identical conditions. Even when drained at off-design conditions, the contoured tank had less liquid residuals at vapor ingestion than the conventional outlet tank. Effects of outflow rate, gravitational environment, and fluid properties on the outlet contour are discussed. Two potential applications of outlet contouring are also presented and discussed.
State-of-the-art Magnetic Resonance Imaging in Vascular Thoracic Outlet Syndrome.
Aghayev, Ayaz; Rybicki, Frank J
2015-05-01
Vascular thoracic outlet syndrome is caused by compression of subclavian/axillary vessels during their passage from the thoracic cavity to the axilla. Early diagnosis and treatment is important to prevent debilitating outcomes of vascular thoracic outlet syndrome. Contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) with equilibrium phase using provocative arm positioning is the optimal examination to determine presence, degree of vascular compression, and complications of vascular thoracic outlet syndrome. This article reviews thoracic outlet anatomy, disorders of the vascular component, and typical imaging findings by contrast-enhanced 3D MRA. Published by Elsevier Inc.
Fluidic Oscillator Having Decoupled Frequency and Amplitude Control
NASA Technical Reports Server (NTRS)
Koklu, Mehti (Inventor)
2017-01-01
A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.
Fluidic Oscillator Having Decoupled Frequency and Amplitude Control
NASA Technical Reports Server (NTRS)
Koklu, Mehti (Inventor)
2016-01-01
A fluidic oscillator having independent frequency and amplitude control includes a fluidic-oscillator main flow channel having a main flow inlet, a main flow outlet, and first and second control ports disposed at opposing sides thereof. A fluidic-oscillator controller has an inlet and outlet. A volume defined by the main flow channel is greater than the volume defined by the controller. A flow diverter coupled to the outlet of the controller defines a first fluid flow path from the controller's outlet to the first control port and defines a second fluid flow path from the controller's outlet to the second control port.
The Patient Burden of Bladder Outlet Obstruction after Prostate Cancer Treatment.
Liberman, Daniel; Jarosek, Stephanie; Virnig, Beth A; Chu, Haitao; Elliott, Sean P
2016-05-01
Bladder outlet obstruction after prostate cancer therapy imposes a significant burden on health and quality of life in men. Our objective was to describe the burden of bladder outlet obstruction after prostate cancer therapy by detailing the type of procedures performed and how often those procedures were repeated in men with recurrent bladder outlet obstruction. Using SEER (Surveillance, Epidemiology and End Results)-Medicare linked data from 1992 to 2007 with followup through 2009 we identified 12,676 men who underwent at least 1 bladder outlet obstruction procedure after prostate cancer therapy, including external beam radiotherapy in 3,994, brachytherapy in 1,485, brachytherapy plus external beam radiotherapy in 1,847, radical prostatectomy in 4,736, radical prostatectomy plus external beam radiotherapy in 369 and cryotherapy in 245. Histogram, incidence rates and Cox proportional hazards models with repeat events analysis were done to describe the burden of repeat bladder outlet obstruction treatments stratified by prostate cancer therapy type. We describe the type of bladder outlet obstruction surgery grouped by level of invasiveness. At a median followup of 8.8 years 44.6% of men underwent 2 or more bladder outlet obstruction procedures. Compared to men who underwent radical prostatectomy those treated with brachytherapy and brachytherapy plus external beam radiotherapy were at increased adjusted risk for repeat bladder outlet obstruction treatment (HR 1.2 and 1.32, respectively, each p <0.05). After stricture incision the men treated with radical prostatectomy or radical prostatectomy plus external beam radiotherapy were most likely to undergo dilation at a rate of 34.7% to 35.0%. Stricture resection/ablation was more common after brachytherapy, external beam radiotherapy or brachytherapy plus external beam radiotherapy at a rate of 28.9% to 41.2%. Almost half of the men with bladder outlet obstruction after prostate cancer therapy undergo more than 1 procedure. Furthermore men with bladder outlet obstruction after radiotherapy undergo more invasive endoscopic therapies and are at higher risk for multiple treatments than men with bladder outlet obstruction after radical prostatectomy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Energy Trends and Their Implications for U.S. Army Installations
2005-09-01
technolo- gies—primarily flue gas desulfurization (FGD) equipment—that reduce the amounts of sulfur dioxide emitted with coal combustion. As mentioned...natural gas are past their peak and world petroleum production is nearing its peak. Growing domestic consump- tion will continue to increase dependence...on foreign and potentially unstable energy sources. Almost half of the existing U.S. natural gas reserves are considered to be either remote or
Central Heating Plant Coal Use Handbook. Volume 1: Technical Reference.
1996-11-01
variation of a dry desulfurization system simply uses dry calcium hydroxide that is injected into the flue gas stream before entry to a fabric filter...97/14, Voll 173 competitive capital and operating costs compared with conventional technology using flue gas desulfurization reduced NOx emissions...ferric iron in slag, expressed as a percentage of the total iron calculated as ferric iron FGD: Flue gas desulfurization filter: A device for
Environmental Compliance Assessment System (ECAS). Kentucky Supplement (Revised)
1994-02-01
vehicles or vehicle bodies. "* FGD - Flue Gas Desulfurization . "* Field-Erected - assembled from components at a final site of operation. "* Flare - a...34* Spare Flue Gas Desulfurization System Module - a separate system of sulfur dioxide emission con- trol equipment capable of treating an amount of flue ...Carryover - particulate matter which is passed from the primary chamber of an incinerator into the flue gas stream. " Particulate Matter Emissions
Consolidated Navy-Marines Environmental Law Deskbook. Revised
1994-05-01
106 ????? 1505 (1992)) FGD Flue Gas Desulfurization FGS Final Governing Standards FICUN Federal Interagency Committee on Urban Noise FIFRA Federal...SIPs. A. SIP management. Each SIP must be approved by EPA and must contain a mix of controls and strategies sufficient to achieve and maintain the...and contain release. Identify the parties carrying out response. If none, state why. EXAMPLE: Gas barriers used to control and contain vapor emissions
Concepts of Resilience for Coastal Systems
2015-11-06
respond to, and adapt to changing conditions and to withstand and recover rapidly from disruptions with minimal damage.” Urban Land Institute, “After...AR5/images/uploads/WGIIAR5-Glossary_FGD.pdf “The capacity of a social- ecological system to cope with a hazardous event or disturbance, responding or...dunes, wetlands Ecological Resilience The capacity of a system to absorb disturbance and reorganize while undergoing change Ecological Resilience
Saramunee, K; Krska, J; Mackridge, A; Richards, J; Suttajit, S; Phillips-Howard, P
2015-06-01
To explore the experience of and willingness to use seven pharmacy public health services related to cardiovascular risk among the general public in England. Mixed-methods study. A mixed-methods study, involving a cross-sectional survey using multiple distribution methods followed by a focus group discussion (FGD) with a sample of survey respondents. From 3596 approachable individuals, 908 questionnaires were completed (response rate 25.3%). Few respondents (2.1-12.7%) had experienced any of the seven pharmacy public health services. About 40% stated they would be willing to use health check services, fewer (9.3-26.3%) were willing to use advisory services. More females, frequent pharmacy users and those in good health were willing to use services in general (P < 0.05). Smokers, overweight individuals and those with alcohol-related problems were most willing to use specific advisory services supporting their problems (P < 0.05). FGD identified barriers to service use; for example, frequent staff changes, seeing pharmacist as medicines suppliers and concerns about competence for these services. The general public are receptive to pharmacy public health services. Pharmacists must consider barriers if uptake of services is to increase. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.
Rehan, Rabiya; Ahmed, Khalid; Khan, Hira; Rehman, Rehana
2016-01-01
Objective: To compare the perception of medical students on the usefulness of the interactive lectures, case-based lectures, and structured interactive sessions (SIS) in teaching and learning of Physiology. Methods: A cross-sectional study was carried out from January to December 2012 at Bahria University Medical & Dental College, Karachi, which had qualitative and quantitative aspects, assessed by self- reported questionnaire and focused group discussion (FGD). The questionnaire was distributed to 100 medical students after completion of first year of teaching of MBBS Physiology. The data was analyzed using SPSS version 15. Differences were considered significant at p-values <0.05 after application of Friedman test. Responses of FGD were analyzed. Results: All the teaching methodologies helped in understanding of precise learning objectives. The comprehension of structure and functions with understanding of difficult concepts was made best possible by SIS (p=0.04, p<0.01). SIS enabled adult learning, self-directed learning, peer learning and critical reasoning more than the other teaching strategies (p< 0.01). Conclusion: SIS involved students who used reasoning skills and power of discussion in a group to comprehend difficult concepts for better understanding of Physiology as compared to interactive and case-based lectures. PMID:28083047
Local election: does bureaucracy become one of main political power?
NASA Astrophysics Data System (ADS)
Amin, Muryanto; Musthafa Sembiring, Walid
2018-03-01
This writing aims to analyze the emergence of bureaucracy as one of political power in local level after the local election is held in Indonesia. Due to information authorization, media network, and stable structure, the bureaucracy soon transforms into political power which can compete with the other political power at the local level. In Medan local election in 2010 and 2015 has evidently proven the power of bureaucracy network in winning the bureaucrat-background candidates. As methods of the research, the researcher held a Focus-Group Discussion (FGD) and had an in-depth interview with ten bureaucracy elites in Medan and local political elites. The observation and Focus-Group Discussion (FGD) are analyzed using qualitative analysis technique typology. The result states that the bureaucracy network in Medan has been used in a massive way as the political power of winning. The structure of bureaucracy – from the top to the low – is involved in the winning. The most governmental programs were applied to attract the mass’ sympathy toward the candidates. The bureaucratic proximity to media network is also used to do a campaign in a massive way. The conclusion of the research is that bureaucracy emerges as a new, massive, effective local political power in the local election.
[Preparation of titanium dioxide particles and properties for flue gas desulfurization].
Luo, Yonggang; Li, Daji; Huang, Zhen
2003-01-01
Under different sintering temperatures(340 degrees C, 440 degrees C, 540 degrees C, 640 degrees C), four TiO2 particles were prepared. The crystal types of all four samples were found to possess anatase structures by XRD. It was obtained by N2 experimental adsorption at low temperature (77K) that their surface areas and average pore size were between 79 and 124 m2/g, 56.8 and 254.8 A respectively. The pore structure of TiO2 particles was characterized by scanning electron microscope (SEM). The tests of adsorption dynamics for FGD and the performance of SO2 removal were investigated in a fixed-bed system for different samples. The results show that SG540 sample which made at 540 degrees C sintering temperature had the most quality among the four samples. It can adsorb SO2 of 38.9 mg for one gram SG540 sample. Different operating conditions for SG540 such as adsorption temperature, SO2 concentration in flue gas and the superficial velocity of flue gas were investigated. TiO2 particles for FGD had more efficiency than other physical sorbents such as active carbon and zeolite. The mechanism for SO2 removal was demonstrated by infrared (IR) spectroscopy and desorption test results to be mainly physical adsorption.
The fate of mercury in coal utilization byproducts
DOE Office of Scientific and Technical Information (OSTI.GOV)
William Aljoe; Thomas Feeley; James Murphy
2005-05-01
The US Department of Energy National Energy Technology Laboratory's (DOE/NETL's) research has helped to further scientific understanding of the environmental characteristics of coal-utilization by-products (CUBs) in both disposal and beneficial utilization applications. The following general observations can be drawn from results of the research that has been carried out to date: There appears to be only minimal mercury release to the environment in typical disposal or utilization applications for CUBs generated using activated carbon injection (ACI) control technologies; There appears to be only minimal mercury release to the environment in typical disposal and utilization applications for CUBs generated using wetmore » FGD control technologies. The potential release of mercury from wet FGD gypsum during the manufacture of wallboard is still under evaluation; The amount of mercury leached from CUB samples tested by DOE/NETL is significantly lower than the federal drinking water standards and water quality criteria for the protection of aquatic life; in many cases, leachate concentrations were below the standard test method detection limits. DOE/NETL will continue to partner with industry and other key stakeholders in carrying out research to better understand the fate of mercury and other trace elements in the byproducts from coal combustion. 16 refs., 6 tabs.« less
Flue gas desulfurization gypsum and fly ash
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-05-01
The Cumberland Fossil Plant (CUF) is located in Stewart County, Tennessee, and began commercial operation in 1972. This is the Tennessee Valley Authority`s newest fossil (coal-burning) steam electric generating plant. Under current operating conditions, the plant burns approximately seven million tons of coal annually. By-products from the combustion of coal are fly ash, approximately 428,000 tons annually, and bottom ash, approximately 115,000 tons annually. Based on historical load and projected ash production rates, a study was initially undertaken to identify feasible alternatives for marketing, utilization and disposal of ash by-products. The preferred alternative to ensure that facilities are planned formore » all by-products which will potentially be generated at CUF is to plan facilities to handle wet FGD gypsum and dry fly ash. A number of different sites were evaluated for their suitability for development as FGD gypsum and ash storage facilities. LAW Engineering was contracted to conduct onsite explorations of sites to develop information on the general mature of subsurface soil, rock and groundwater conditions in the site areas. Surveys were also conducted on each site to assess the presence of endangered and threatened species, wetlands and floodplains, archaeological and cultural resources, prime farmland and other site characteristics which must be considered from an environmental perspective.« less
Tunstall, Helena; Shortt, Niamh K; Niedzwiedz, Claire L; Richardson, Elizabeth A; Mitchell, Richard J; Pearce, Jamie R
2018-06-01
Despite long-term falls in global adult smoking prevalence and over 50 years of tobacco control policies, adolescent smoking persists. Research suggests greater densities of tobacco retail outlets in residential neighbourhoods are associated with higher adolescent smoking rates. Policies to reduce retail outlets have therefore been identified by public health researchers as a potential 'new frontier' in tobacco control. Better understanding of the pathways linking density of tobacco retailers and smoking behaviour could support these policies. In this study we use path analysis to assess how outlet density in the home environment is related to adolescent tobacco knowledge, beliefs, retail purchases and price in Scotland. We assessed 22,049 13 and 15 year old respondents to the nationally representative cross-sectional 2010 Scottish School Adolescent Lifestyle and Substance Use Survey. Outlet density was based on Scottish Tobacco Retailers Register, 2012, data. A spatially-weighted Kernel Density Estimation measure of outlet density within 400 m of respondents' home postcode was grouped into tertiles. The analysis considered whether outlet density was associated with the number of cigarette brands adolescents could name, positive beliefs about smoking, whether smokers purchased cigarettes from shops themselves or through adult proxies and perceived cost of cigarettes. Models were stratified by adolescent smoking status. The path analyses indicated that outlet density was not associated with most outcomes, but small, significant direct effects on knowledge of cigarette brands among those who had never smoked were observed. With each increase in outlet density tertile the mean number of brands adolescents could name rose by 0.07 (mean = 1.60; SD = 1.18; range = 4). This suggests greater outlet densities may have affected adolescents' knowledge of cigarette brands but did not encourage positive attitudes to smoking, purchases from shops or lower cigarette prices. Exposure to tobacco outlets may influence adolescents' awareness of tobacco products, a potential pathway to smoking behaviour. Copyright © 2018 Elsevier Ltd. All rights reserved.
Tobacco Retail Outlet Density and Young Adult Tobacco Initiation
Pearson, Jennifer L.; Anesetti-Rothermel, Andrew; Xiao, Haijun; Kirchner, Thomas R.; Vallone, Donna
2016-01-01
Background: A growing body of evidence indicates that the density of tobacco retail outlets around the home residence may influence tobacco use among youth and adults. The purpose of this study was to examine the impact of neighborhood tobacco retail outlet density on young adult initiation of different tobacco product types. Methods: Cross-sectional data from a 2013 nationally representative sample of young adults aged 18–34 was examined in relation to a 2012 geocoded listing of all outlets likely to sell tobacco in the United States. Separate multivariable logistic regression analyses examined associations between neighborhood outlet density and past 6 months first use of cigarettes, non-cigarette combustible products, and noncombustible products among adults aged 18–24 and 25–34. Results: Outlet density was significantly associated with recent initiation of cigarettes and other combustibles, but this impact varied for younger and older groups. Increased density was significantly associated with a higher likelihood of initiating cigarette use among adults aged 25–34 (OR = 3.75, 95% CI = 1.18, 11.90), and of initiating non-cigarette combustible use among 18–24 year olds (OR = 3.16, 95% CI = 1.03, 9.74). There was no impact of outlet density on recent noncombustible product initiation among either group. Conclusion: This study is the first to examine the impact of tobacco outlet density on young adult initiation of cigarettes and other tobacco products. Findings demonstrate that residential neighborhood outlet density is associated with recent initiation of combustible products and this effect varies by product type and age. The tobacco outlet environment may be a critical factor in promoting young adult tobacco use initiation. PMID:25666816
Tobacco retail outlet density and risk of youth smoking in New Zealand.
Marsh, Louise; Ajmal, Ali; McGee, Rob; Robertson, Lindsay; Cameron, Claire; Doscher, Crile
2016-12-01
Evidence suggests inconsistent findings on the relationship between density of tobacco outlets around schools and risk of smoking among students. This study examines the density of tobacco outlets around secondary schools in New Zealand (NZ) and current smoking, experimental smoking, susceptibility to smoking, and attempted and successful tobacco purchasing. Smoking data came from the 2012 ASH Year 10 survey, a national survey of youth smoking in NZ. Geographic Information Systems were used to map tobacco retail outlets; a layer of secondary school locations was obtained from Koordinates.com. Logistic regression examined the relationship between density of outlets around schools and smoking behaviours, adjusting for individual-level and school-level confounders. Of the 27 238 students surveyed, 3.5% (952) were current smokers, 4.1% (n=1 128) were experimental smokers, and 39.8% (10 454) of nonsmokers were susceptible to smoking. An inverse relationship was found between the density of tobacco retail outlets and current smoking. Current smokers were significantly more likely to attempt to purchase tobacco if the density of tobacco retail outlets around their school was high. Non-smoking students were more likely to be susceptible to smoking if the density of tobacco outlets around their school was high. There was no statistically significant association between density of tobacco outlets and successful purchasing, nor experimental smoking. Restricting the permitted density of tobacco retail outlets around schools should be part of comprehensive tobacco control. In this regard, both smokers and non-smokers support the introduction of increased regulation of the tobacco retail environment to achieve our national smoke-free 2025 goal. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Local tobacco policy and tobacco outlet density: associations with youth smoking.
Lipperman-Kreda, Sharon; Grube, Joel W; Friend, Karen B
2012-06-01
This study investigates the associations between local tobacco policy, tobacco outlet density, and youth smoking. A primary focus is on whether local tobacco policy moderates the relation between outlet density and youth smoking. In all, 1,491 youth (51.9% male, mean age = 14.7 years, standard deviation = 1.05) in 50 midsized California cities were surveyed through a computer-assisted telephone interview. Measures of local clean air policy and youth access policy were created based on a review of tobacco policies in these cities. Outlet density was calculated as the number of retail tobacco outlets per 10,000 persons, and city characteristics were obtained from 2000 U.S. Census data. Using multilevel regression analyses and controlling for city characteristics, tobacco outlet density was positively associated with youth smoking. No significant main effects were found for the two tobacco policy types on any of the smoking outcomes after controlling for interactions and covariates. However, statistically significant interactions were found between local clean air policy and tobacco outlet density for ever smoked and past 12-month cigarette smoking. Comparisons of simple slopes indicated that the positive associations between tobacco outlet density and youth smoking behaviors were stronger at the lowest level of local clean air policy compared with the moderate and high levels. Our results suggest that tobacco outlet density is related to youth smoking. In addition, local clean air policy may act as a moderator of relationship between tobacco outlet density and youth smoking, such that density is less important at moderate and high levels of this tobacco policy. Copyright © 2012 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.
Maguire, Eva R.; Burgoine, Thomas; Monsivais, Pablo
2015-01-01
Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. PMID:25841285
The Geography of Fast Food Outlets: A Review
Fraser, Lorna K.; Edwards, Kimberly L.; Cade, Janet; Clarke, Graham P.
2010-01-01
The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity. PMID:20623025
The geography of Fast Food outlets: a review.
Fraser, Lorna K; Edwards, Kimberly L; Cade, Janet; Clarke, Graham P
2010-05-01
The availability of food high in fat, salt and sugar through Fast Food (FF) or takeaway outlets, is implicated in the causal pathway for the obesity epidemic. This review aims to summarise this body of research and highlight areas for future work. Thirty three studies were found that had assessed the geography of these outlets. Fourteen studies showed a positive association between availability of FF outlets and increasing deprivation. Another 13 studies also included overweight or obesity data and showed conflicting results between obesity/overweight and FF outlet availability. There is some evidence that FF availability is associated with lower fruit and vegetable intake. There is potential for land use policies to have an influence on the location of new FF outlets. Further research should incorporate good quality data on FF consumption, weight and physical activity.
Socioeconomic Determinants of Exposure to Alcohol Outlets
Morrison, Christopher; Gruenewald, Paul J.; Ponicki, William R.
2015-01-01
Objective: Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Method: Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Results: Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. Conclusions: These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world. PMID:25978830
Off-premise alcohol outlet characteristics and violence.
Snowden, Aleksandra J; Pridemore, William Alex
2014-07-01
There is considerable evidence of an association between alcohol outlet density and violence. Although prior research reveals the importance of specific characteristics of bars on this association and that the relationship between bar density and violence may be moderated by these characteristics, there are few similar studies of the characteristics of off-premise outlets (e.g., liquor and convenience stores). We examined whether immediate environment, business practice, staff, and patron characteristics of off-premise alcohol outlets are associated with simple and aggravated assault density. Cross-sectional design using aggregate data from 65 census block groups in a non-metropolitan college town, systematic social observation, and spatial modeling techniques. We found limited effects of immediate environment, business practice, staff, and patron characteristics on simple assault density and no effect on aggravated assault density. Only two out of 17 characteristics were associated with simple assault density (i.e., nearby library and male patrons). This is the first study to examine the association between several off-premise alcohol outlet characteristics and assault. Our findings suggest that where the off-premise outlets are located, how well the immediate environment is maintained, what types of beverages the outlets sell, who visits them, and who works there matter little in their association with violence. This suggests the importance of outlet density itself as a primary driver of any association with violence. Public policies aimed at reducing alcohol outlet density or clustering may be useful for reducing violence.
Mair, Christina; Gruenewald, Paul J; Ponicki, William R; Remer, Lillian
2013-01-01
Groups of potentially violent drinkers may frequent areas of communities with large numbers of alcohol outlets, especially bars, leading to greater rates of alcohol-related assaults. This study assessed direct and moderating effects of bar densities on assaults across neighborhoods. We analyzed longitudinal population data relating alcohol outlet densities (total outlet density, proportion bars/pubs, proportion off-premise outlets) to hospitalizations for assault injuries in California across residential ZIP code areas from 1995 through 2008 (23,213 space-time units). Because few ZIP codes were consistently defined over 14 years and these units are not independent, corrections for unit misalignment and spatial autocorrelation were implemented using Bayesian space-time conditional autoregressive models. Assaults were related to outlet densities in local and surrounding areas, the mix of outlet types, and neighborhood characteristics. The addition of one outlet per square mile was related to a small 0.23% increase in assaults. A 10% greater proportion of bars in a ZIP code was related to 7.5% greater assaults, whereas a 10% greater proportion of bars in surrounding areas was related to 6.2% greater assaults. The impacts of bars were much greater in areas with low incomes and dense populations. The effect of bar density on assault injuries was well supported and positive, and the magnitude of the effect varied by neighborhood characteristics. Posterior distributions from these models enabled the identification of locations most vulnerable to problems related to alcohol outlets.
Socioeconomic determinants of exposure to alcohol outlets.
Morrison, Christopher; Gruenewald, Paul J; Ponicki, William R
2015-05-01
Alcohol outlets tend to be located in lower income areas, exposing lower income populations to excess risks associated with alcohol sales through these establishments. The objective of this study was to test two hypotheses about the etiology of these differential exposures based on theories of the economic geography of retail markets: (a) outlets will locate within or near areas of high alcohol demand, and (b) outlets will be excluded from areas with high land and structure rents. Data from the 2010 National Drug Strategy Household Survey were used to develop a surrogate for alcohol demand (i.e., market potential) at two census geographies for the city of Melbourne, Australia. Bayesian conditional autoregressive Poisson models estimated multilevel spatial relationships between counts of bars, restaurants, and off-premise outlets and market potential, income, and zoning ordinances (Level 1: n = 8,914). Market potentials were greatest in areas with larger older age, male, English-speaking, high-income populations. Independent of zoning characteristics, greater numbers of outlets appeared in areas with greater market potentials and the immediately surrounding areas. Greater income excluded outlets in local and surrounding areas. These findings are consistent with the hypothesis that alcohol outlets are located in areas with high demand and are excluded from high-income areas. These processes appear to take place at relatively small geographic scales, encourage the concentration of outlets in specific low-income areas, and represent a very general economic process likely to take place in communities throughout the world.
Concentration of tobacco advertisements at SNAP and WIC stores, Philadelphia, Pennsylvania, 2012.
Hillier, Amy; Chilton, Mariana; Zhao, Qian-Wei; Szymkowiak, Dorota; Coffman, Ryan; Mallya, Giridhar
2015-02-05
Tobacco advertising is widespread in urban areas with racial/ethnic minority and low-income households that participate in nutrition assistance programs. Tobacco sales and advertising are linked to smoking behavior, which may complicate matters for low-income families struggling with disparate health risks relating to nutrition and chronic disease. We investigated the relationship between the amount and type of tobacco advertisements on tobacco outlets and the outlet type and location. By using field visits and online images, we inspected all licensed tobacco retail outlets in Philadelphia (N = 4,639). Point pattern analyses were used to identify significant clustering of tobacco outlets and outlets with exterior tobacco advertisements. Logistic regression was used to analyze the relationship between the outlet's acceptance of Supplemental Nutrition Assistance Program (SNAP) and Special Supplemental Nutrition Program for Women, Infants, and Children (WIC) and the presence of tobacco advertisements. Tobacco outlets with exterior tobacco advertisements were significantly clustered in several high-poverty areas. Controlling for racial/ethnic and income composition and land use, SNAP and WIC vendors were significantly more likely to have exterior (SNAP odds ratio [OR], 2.11; WIC OR, 1.59) and interior (SNAP OR, 3.43; WIC OR, 1.69) tobacco advertisements than other types of tobacco outlets. Tobacco advertising is widespread at retail outlets, particularly in low-income and racial/ethnic minority neighborhoods. Policy makers may be able to mitigate the effects of this disparate exposure through tobacco retail licensing, local sign control rules, and SNAP and WIC authorization.
The association between the geography of fast food outlets and childhood obesity rates in Leeds, UK.
Fraser, Lorna K; Edwards, Kimberley L
2010-11-01
To analyse the association between childhood overweight and obesity and the density and proximity of fast food outlets in relation to the child's residential postcode. This was an observational study using individual level height/weight data and geographic information systems methodology. Leeds in West Yorkshire, UK. This area consists of 476 lower super-output areas. Children aged 3-14 years who lived within the Leeds metropolitan boundaries (n=33,594). The number of fast food outlets per area and the distance to the nearest fast food outlet from the child's home address. The weight status of the child: overweight, obese or neither. 27.1% of the children were overweight or obese with 12.6% classified as obese. There is a significant positive correlation (p<0.001) between density of fast food outlets and higher deprivation. A higher density of fast food outlets was significantly associated (p=0.02) with the child being obese (or overweight/obese) in the generalised estimating equation model which also included sex, age and deprivation. No significant association between distance to the nearest fast food outlet and overweight or obese status was found. There is a positive relationship between the density of fast food outlets per area and the obesity status of children in Leeds. There is also a significant association between fast food outlet density and areas of higher deprivation. Copyright © 2010 Elsevier Ltd. All rights reserved.
Alcohol outlet density and assault: a spatial analysis.
Livingston, Michael
2008-04-01
A large number of studies have found links between alcohol outlet densities and assault rates in local areas. This study tests a variety of specifications of this link, focusing in particular on the possibility of a non-linear relationship. Cross-sectional data on police-recorded assaults during high alcohol hours, liquor outlets and socio-demographic characteristics were obtained for 223 postcodes in Melbourne, Australia. These data were used to construct a series of models testing the nature of the relationship between alcohol outlet density and assault, while controlling for socio-demographic factors and spatial auto-correlation. Four types of relationship were examined: a normal linear relationship between outlet density and assault, a non-linear relationship with potential threshold or saturation densities, a relationship mediated by the socio-economic status of the neighbourhood and a relationship which takes into account the effect of outlets in surrounding neighbourhoods. The model positing non-linear relationships between outlet density and assaults was found to fit the data most effectively. An increasing accelerating effect for the density of hotel (pub) licences was found, suggesting a plausible upper limit for these licences in Melbourne postcodes. The study finds positive relationships between outlet density and assault rates and provides evidence that this relationship is non-linear and thus has critical values at which licensing policy-makers can impose density limits.
NASA Technical Reports Server (NTRS)
Howe, Robert H. (Inventor); Flynn, Kenneth P. (Inventor); Stapleton, Thomas J. (Inventor)
2014-01-01
A contaminate control device for filtering contaminates from a gas such as air is provided. The device includes a housing having a first inlet and a first outlet. An axial flow filter is fluidly coupled between the first inlet and the first outlet, the axial flow filter has a second inlet and a second outlet. A second filter disposed about the axial flow filter and is fluidly coupled between the first inlet and the first outlet, the second filter having a third inlet on an inner diameter and a third outlet disposed on an outer diameter. A flow restrictor is fluidly coupled between the second inlet and the first inlet.
23. DOWNSTREAM VIEW OF COMPLETED OUTLET CONTROL STRUCTURE.... Volume XIX, ...
23. DOWNSTREAM VIEW OF COMPLETED OUTLET CONTROL STRUCTURE.... Volume XIX, No. 8, April 12, 1940. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
Outlet diffusers to increase culvert capacity.
DOT National Transportation Integrated Search
2016-06-01
Aging infrastructure and changing weather patterns present the need to increase the capacity of existing highway culverts. This research approaches this challenge through the use of diffuser outlet systems to increase pipe capacity and reduce outlet ...
Snowden, Aleksandra J
2016-01-01
This study examined the role that race/ethnicity and social disorganization play in alcohol availability in Milwaukee, Wisconsin, census block groups. This study estimated negative binomial regression models to examine separately the relationship between neighborhood racial/ethnic composition and social disorganization levels for (1) total, (2) on-premise, and (3) off-premise alcohol outlets. Results of this study suggest that proportion Hispanic was positively associated with total and with off-premise alcohol outlets. Second, proportion African American was negatively associated with on-premise alcohol outlets and positively associated with off-premise alcohol outlets. Proportion Asian was not associated with total, on-premise, or off-premise alcohol outlets. However, the effects of race/ethnicity on alcohol availability were either unrelated or negatively related to alcohol outlet availability once neighborhood social disorganization levels were taken into account, and social disorganization was positively and significantly associated with all alcohol outlet types. Neighborhood characteristics contribute to alcohol availability and must be considered in any efforts aimed toward prevention of alcohol-related negative health and social outcomes.
NASA Astrophysics Data System (ADS)
Leydet, D.; Carlson, A. E.; Sinclair, G.; Teller, J. T.; Breckenridge, A. J.; Caffee, M. W.; Barth, A. M.
2015-12-01
The chronology for the eastern outlets of glacial Lake Agassiz holds important consequences for the cause of Younger Dryas cold event during the last deglaciation. Eastward routing of Lake Agassiz runoff was originally hypothesized to have triggered the Younger Dryas. However, currently the chronology of the eastern outlets is only constrained by minimum-limiting radiocarbon ages that could suggest the eastern outlets were still ice covered at the start of the Younger Dryas at ~12.9 ka BP, requiring a different forcing of this abrupt climate event. Nevertheless, the oldest radiocarbon ages are still consistent with an ice-free eastern outlet at the start of the Younger Dryas. Here we will present preliminary 10-Be cosmogenic surface exposure ages from the North Lake, Flat Rock Lake, glacial Lake Kaministiquia, and Lake Nipigon outlets located near Thunder Bay, Ontario. These ages will date the timing of the deglaciation of the Laurentide ice sheet in the eastern outlet region of glacial Lake Agassiz. This will provide an important constraint for the hypothesized freshwater forcing of the cause of Younger Dryas cold event.
Lean direct injection diffusion tip and related method
Varatharajan, Balachandar [Cincinnati, OH; Ziminsky, Willy S [Simpsonville, SC; Lipinski, John [Simpsonville, SC; Kraemer, Gilbert O [Greer, SC; Yilmaz, Ertan [Niskayuna, NY; Lacy, Benjamin [Greer, SC
2012-08-14
A nozzle for a gas turbine combustor includes a first radially outer tube defining a first passage having an inlet and an outlet, the inlet adapted to supply air to a reaction zone of the combustor. A center body is located within the first radially outer tube, the center body including a second radially intermediate tube for supplying fuel to the reaction zone and a third radially inner tube for supplying air to the reaction zone. The second intermediate tube has a first outlet end closed by a first end wall that is formed with a plurality of substantially parallel, axially-oriented air outlet passages for the additional air in the third radially inner tube, each air outlet passage having a respective plurality of associated fuel outlet passages in the first end wall for the fuel in the second radially intermediate tube. The respective plurality of associated fuel outlet passages have non-parallel center axes that intersect a center axis of the respective air outlet passage to locally mix fuel and air exiting said center body.
Binfa, Lorena; Pantoja, Loreto; Ortiz, Jovita; Gurovich, Marcela; Cavada, Gabriel; Foster, Jennifer
2016-04-01
in 2010, a pilot study was conducted among women who were attended by midwives in the public sector in Santiago, Chile. The purpose of that study was to evaluate the implementation of the 'Model of Integrated and Humanized Health Services', and the Clinical Guide for Humanized Attention during Labour and Childbirth. Results of that study indicated 92.7% of women had medically augmented labours (artificial rupture of the membranes, oxytocin and epidural analgesia). One third of the women reported discontent with the care they received. This study replicated the pilot study (2010) and was conducted in seven regional hospitals across Chile. The objectives were to : (i) describe selected obstetric and neonatal outcomes of women who received care according to this new guide, (ii) identify the level of maternal-neonatal well-being after experiencing this modality of attention, and (iii) explore professionals' perceptions (obstetricians and midwives), as well as consumers' perceptions of this humanised assistance during labour and childbirth. this is a cross sectional and descriptive, mixed methods study, conducted in two phases. The first phase was quantitative, measuring midwifery processes of care and maternal perceptions of well-being in labour and childbirth. The second phase was qualitative, exploring the perceptions of women, midwives and obstetricians regarding the discrepancy between the national guidelines and actual practice. maternity units from seven regional hospitals from the northern, central and southern regions and two metropolitan hospitals across Chile. 1882 parturient women in the quantitative phase (including the two Metropolitan hospitals published previously). Twenty-six focus groups discussions (FGD) participated from the regional and metropolitan hospitals for the qualitative phase. MEASUREMENTS/FINDINGS: all women started labour spontaneously; 74% of women had spontaneous vaginal childbirth. Caesarean section was the outcome for 20%, and 6% had childbirth assisted with forceps. A high number of medical interventions continued to be performed in all regions, deviating widely from adherence to the national clinical guidelines. Most of the women did not receive any oral hydration, almost all received intravenous hydration; most were under continuous foetal monitoring and medically augmented labour. The majority of women received artificial rupture of membranes, epidural anaesthesia and episiotomy. Most delivered in the lithotomy position. Two thirds of women surveyed perceived adequate well-being in labour and childbirth. Findings from focus group discussions of women (FGD=9; n=27 women), midwives (FGD=9; n=40) and doctors (FGD=8; n=29) indicated lack of infrastructure for family participation in birth, inadequate training and orientation to the national guidelines for practice, and lack of childbirth preparation among women. Some women reported mistreatment by personnel. Some midwives reported lack of autonomy to manage birth physiologically. birth is managed by midwives across the public sector in Chile. Despite evidence-based guidelines published in 2007 by the Ministry of Health, birth is not managed according to the guidelines in most cases. Women feel that care is adequate, although some women report mistreatment. efforts to provide midwife-led care and include women in participatory models of antenatal care are recommended to promote women-centred care in accordance with the Chilean national guidelines. Copyright © 2016 Elsevier Ltd. All rights reserved.
39. OUTLET WORKS: CONTROL HOUSE STRUCTURAL DETAILS. Sheet 33, ...
39. OUTLET WORKS: CONTROL HOUSE - STRUCTURAL DETAILS. Sheet 33, August 20, 1938. File no. SA 121/72. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
38. OUTLET WORKS: CONTROL HOUSE PLAN AND ELEVATIONS. Sheet ...
38. OUTLET WORKS: CONTROL HOUSE - PLAN AND ELEVATIONS. Sheet 32, August 20, 1938. File no. SA 121/71. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
34. OUTLET WORKS: GATES ELEVATIONS AND SECTION. Sheet 43, ...
34. OUTLET WORKS: GATES - ELEVATIONS AND SECTION. Sheet 43, August 20, 1938. File no. SA 121/89(?). - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
43. OUTLET WORKS: SERVICE BRIDGE PLAN AND ELEVATION. Sheet ...
43. OUTLET WORKS: SERVICE BRIDGE - PLAN AND ELEVATION. Sheet 37, August 20, 1938. File no. SA 121/76. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
45. OUTLET WORKS: SERVICE BRIDGE BEARING DETAILS. Sheet 39, ...
45. OUTLET WORKS: SERVICE BRIDGE - BEARING DETAILS. Sheet 39, August 20, 1938. File no. SA 121/78. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
26. UPSTREAM VIEW OF DISCHARGE END OF OUTLET STRUCTURE.... Volume ...
26. UPSTREAM VIEW OF DISCHARGE END OF OUTLET STRUCTURE.... Volume XVI, No. 17, September 29, 1939. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
44. OUTLET WORKS: SERVICE BRIDGE GIRDER DETAILS. Sheet 38, ...
44. OUTLET WORKS: SERVICE BRIDGE - GIRDER DETAILS. Sheet 38, August 20, 1938. File no. SA 121/77. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
35. OUTLET WORKS: GATE HOIST ASSEMBLY. Sheet 44, August 20, ...
35. OUTLET WORKS: GATE HOIST ASSEMBLY. Sheet 44, August 20, 1938. File no. SA 121/84(?). - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
31. OUTLET WORKS: INTAKE PLAN AND SECTIONS. Sheet 21, ...
31. OUTLET WORKS: INTAKE - PLAN AND SECTIONS. Sheet 21, August 20, 1938. File no. SA 121/60. - Prado Dam, Outlet Works, Santa Ana River near junction of State Highways 71 & 91, Corona, Riverside County, CA
Antivortex Device for Multi-Outlet Liquid Reservoir
NASA Technical Reports Server (NTRS)
Grayson, Gary David (Inventor); Addison, Stephen Michael (Inventor)
2016-01-01
A liquid reservoir with a sump includes at least two outlet ports in fluid communication with a fluid conduit. An anti-vortex device includes a first plate extending across the at least two outlet ports and a second plate coupled to the first plate and extending substantially perpendicular to the first plate. The anti-vortex device is configured to disrupt formation of a vortex formed by liquid passing from the reservoir through said outlet ports.
Maguire, Eva R; Burgoine, Thomas; Monsivais, Pablo
2015-05-01
Socioeconomic disparities in the food environment are known to exist but with little understanding of change over time. This study investigated the density of takeaway food outlets and presence of supermarkets in Norfolk, UK between 1990 and 2008. Data on food retail outlet locations were collected from telephone directories and aggregated within electoral wards. Supermarket presence was not associated with area deprivation over time. Takeaway food outlet density increased overall, and was significantly higher in more deprived areas at all time points; furthermore, socioeconomic disparities in takeaway food outlet density increased across the study period. These findings add to existing evidence and help assess the need for environmental interventions to reduce disparities in the prevalence of unhealthy food outlets. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Sorbent-Based Atmosphere Revitalization System
NASA Technical Reports Server (NTRS)
Knox, James C (Inventor); Miller, Lee A. (Inventor)
2017-01-01
The present invention is a sorbent-based atmosphere revitalization (SBAR) system using treatment beds each having a bed housing, primary and secondary moisture adsorbent layers, and a primary carbon dioxide adsorbent layer. Each bed includes a redirecting plenum between moisture adsorbent layers, inlet and outlet ports connected to inlet and outlet valves, respectively, and bypass ports connected to the redirecting plenums. The SBAR system also includes at least one bypass valve connected to the bypass ports. An inlet channel connects inlet valves to an atmosphere source. An outlet channel connects the bypass valve and outlet valves to the atmosphere source. A vacuum channel connects inlet valves, the bypass valve and outlet valves to a vacuum source. In use, one bed treats air from the atmosphere source while another bed undergoes regeneration. During regeneration, the inlet, bypass, and outlet valves sequentially open to the vacuum source, removing accumulated moisture and carbon dioxide.
Thoracic outlet syndrome part 2: conservative management of thoracic outlet.
Watson, L A; Pizzari, T; Balster, S
2010-08-01
Thoracic outlet syndrome (TOS) is a symptom complex attributed to compression of the nerves and vessels as they exit the thoracic outlet. Classified into several sub-types, conservative management is generally recommended as the first stage treatment in favor of surgical intervention. In cases where postural deviations contribute substantially to compression of the thoracic outlet, the rehabilitation approach outlined in this masterclass will provide the clinician with appropriate management strategies to help decompress the outlet. The main component of the rehabilitation program is the graded restoration of scapula control, movement, and positioning at rest and through movement. Adjunctive strategies include restoration of humeral head control, isolated strengthening of weak shoulder muscles, taping, and other manual therapy techniques. The rehabilitation outlined in this paper also serves as a model for the management of any shoulder condition where scapula dysfunction is a major contributing factor. Copyright 2010 Elsevier Ltd. All rights reserved.
Complex Greenland outlet glacier flow captured
Aschwanden, Andy; Fahnestock, Mark A.; Truffer, Martin
2016-01-01
The Greenland Ice Sheet is losing mass at an accelerating rate due to increased surface melt and flow acceleration in outlet glaciers. Quantifying future dynamic contributions to sea level requires accurate portrayal of outlet glaciers in ice sheet simulations, but to date poor knowledge of subglacial topography and limited model resolution have prevented reproduction of complex spatial patterns of outlet flow. Here we combine a high-resolution ice-sheet model coupled to uniformly applied models of subglacial hydrology and basal sliding, and a new subglacial topography data set to simulate the flow of the Greenland Ice Sheet. Flow patterns of many outlet glaciers are well captured, illustrating fundamental commonalities in outlet glacier flow and highlighting the importance of efforts to map subglacial topography. Success in reproducing present day flow patterns shows the potential for prognostic modelling of ice sheets without the need for spatially varying parameters with uncertain time evolution. PMID:26830316
Alcohol outlet business hours and violent crime in New York state.
Schofield, Timothy P; Denson, Thomas F
2013-01-01
Alcohol-related harm places a significant strain on victims, perpetrators and society. The present research reports on how licensed alcohol outlet business hours may influence the reported incidence of interpersonal violence and the associated burden of disease. We examined the relationship between alcohol outlet business hours and violent crime in 2009 in New York State (excluding New York City). Regression analyses modeled the burden of disease for the violence associated with outlet business hours. Every 1 h increase in weekly outlet business hours was associated with a greater reported incidence of violent crimes generally, more reported aggravated assaults and more reported non-gun violence. The estimated cost from having licensed premises open after 1 a.m. was $194 million in 2009. The findings suggest that alcohol outlet business hours affect the incidence of reported violence even in regions that would not be considered to have severe problems with alcohol-fueled violence.
Glacier Changes in the Russian High Arctic.
NASA Astrophysics Data System (ADS)
Pritchard, M. E.; Willis, M. J.; Melkonian, A. K.; Golos, E. M.; Stewart, A.; Ornelas, G.; Ramage, J. M.
2014-12-01
We provide new surveys of ice speeds and surface elevation changes for ~40,000 km2 of glaciers and ice caps at the Novaya Zemlya (NovZ) and Severnaya Zemlya (SevZ) Archipelagoes in the Russian High Arctic. The contribution to sea level rise from this ice is expected to increase as the region continues to warm at above average rates. We derive ice speeds using pixel-tracking on radar and optical imagery, with additional information from InSAR. Ice speeds have generally increased at outlet glaciers compared to those measured using interferometry from the mid-1990s'. The most pronounced acceleration is at Inostrantseva Glacier, one of the northernmost glaciers draining into the Barents Sea on NovZ. Thinning rates over the last few decades are derived by regressing stacked elevations from multiple Digital Elevations Models (DEMs) sourced from ASTER and Worldview stereo-imagery and cartographically derived DEMs. DEMs are calibrated and co-registered using ICESat returns over bedrock. On NovZ thinning of between 60 and 100 meters since the 1950s' is common. Similar rates between the late 1980s' and the present are seen at SevZ. We examine in detail the response of the outlet glaciers of the Karpinsky and Russanov Ice Caps on SevZ to the rapid collapse of the Matusevich Ice Shelf in the late summer of 2012. We do not see a dynamic thinning response at the largest feeder glaciers. This may be due to the slow response of the cold polar glaciers to changing boundary conditions, or the glaciers may be grounded well above sea level. Speed increases in the interior are difficult to assess with optical imagery as there are few trackable features. We therefore use pixel tracking on Terra SARX acquisitions before and after the collapse of the ice shelf to compute rates of flow inland, at slow moving ice. Interior ice flow has not accelerated in response to the collapse of the ice shelf but interior rates at the Karpinsky Ice Cap have increased by about 50% on the largest outlet glacier compared to rates found using ERS data in the mid-90s. Speeds have at least doubled at some of the smaller glaciers that feed the Matusevich from the south. We investigate the causes of acceleration at both archipelagoes by comparing sea surface temperatures and passive microwave observations of the timing and duration of ice surface melting.