Sample records for stand high performance

  1. Laparoscopic cholecystectomy poses physical injury risk to surgeons: analysis of hand technique and standing position.

    PubMed

    Youssef, Yassar; Lee, Gyusung; Godinez, Carlos; Sutton, Erica; Klein, Rosemary V; George, Ivan M; Seagull, F Jacob; Park, Adrian

    2011-07-01

    This study compares surgical techniques and surgeon's standing position during laparoscopic cholecystectomy (LC), investigating each with respect to surgeons' learning, performance, and ergonomics. Little homogeneity exists in LC performance and training. Variations in standing position (side-standing technique vs. between-standing technique) and hand technique (one-handed vs. two-handed) exist. Thirty-two LC procedures performed on a virtual reality simulator were video-recorded and analyzed. Each subject performed four different procedures: one-handed/side-standing, one-handed/between-standing, two-handed/side-standing, and two-handed/between-standing. Physical ergonomics were evaluated using Rapid Upper Limb Assessment (RULA). Mental workload assessment was acquired with the National Aeronautics and Space Administration-Task Load Index (NASA-TLX). Virtual reality (VR) simulator-generated performance evaluation and a subjective survey were analyzed. RULA scores were consistently lower (indicating better ergonomics) for the between-standing technique and higher (indicating worse ergonomics) for the side-standing technique, regardless of whether one- or two-handed. Anatomical scores overall showed side-standing to have a detrimental effect on the upper arms and trunk. The NASA-TLX showed significant association between the side-standing position and high physical demand, effort, and frustration (p<0.05). The two-handed technique in the side-standing position required more effort than the one-handed (p<0.05). No difference in operative time or complication rate was demonstrated among the four procedures. The two-handed/between-standing method was chosen as the best procedure to teach and standardize. Laparoscopic cholecystectomy poses a risk of physical injury to the surgeon. As LC is currently commonly performed in the United States, the left side-standing position may lead to increased physical demand and effort, resulting in ergonomically unsound conditions for the surgeon. Though further investigations should be conducted, adopting the between-standing position deserves serious consideration as it may be the best short-term ergonomic alternative.

  2. Reward and Visual Feedback Relative to the Performance and Mechanical Efficiency of High School Girls in the Standing Broad Jump.

    ERIC Educational Resources Information Center

    Zebas, Carole J.

    This study focuses on changes occurring in selected mechanical components of high school girls performing the standing broad jump, and collects data pertaining to the effects of monetary reward and videotape feedback upon the following components: (a) distance jumped, (b) maximum angle of knee flexion, (c) maximum angle of hip flexion, (d) hip…

  3. Added Value of Physical Performance Measures in Predicting Adverse Health-Related Events: Results from the Health, Aging, and Body Composition Study

    PubMed Central

    Cesari, Matteo; Kritchevsky, Stephen B; Newman, Anne B; Simonsick, Eleanor M; Harris, Tamara B; Penninx, Brenda W; Brach, Jennifer S; Tylavsky, Frances A; Satterfield, Suzanne; Bauer, Doug C; Rubin, Susan M; Visser, Marjolein; Pahor, Marco

    2009-01-01

    Objectives To determine how three different physical performance measures (PPM) combine for added utility in predicting adverse health events in elders. Design Prospective cohort study. Setting Health, Aging, and Body Composition Study. Participants 3,024 well-functioning older persons (mean age 73.6 years). Measurements Timed gait, repeated chair stands and balance (semi- and full-tandem, and single leg stands each held for 30 seconds) tests were administered at baseline. Usual gait speed was categorized to distinguish high and low risk participants using the previously established 1 m/sec cut-point. The same population-percentile (21.3%) was used to identify cut-points for repeated chair stands (17.05 sec) and balance (53 sec) tests. Cox proportional hazard analyses were performed to evaluate the added value of PPM in predicting mortality, hospitalization, and (severe) mobility limitation events over 6.9 years of follow-up. Results Risk estimates for developing adverse health-related events were similarly large for each of the three high risk groups considered separately. A greater number of PPM scores at the high risk level was associated with a greater risk of developing adverse health-related events. When all three PPMs were considered, having only one poor performance was sufficient to indicate a highly significant higher risk of (severe) lower extremity and mortality events. Conclusion Although gait speed is considered the most important predictor of adverse health events, these findings demonstrate that poor performance on other tests of lower extremity function are equally prognostic. This suggests that chair stand and standing balance performance may be adequate substitutes when gait speed is unavailable. PMID:19207142

  4. Assisting people with multiple disabilities actively correct abnormal standing posture with a Nintendo Wii balance board through controlling environmental stimulation.

    PubMed

    Shih, Ching-Hsiang; Shih, Ching-Tien; Chu, Chiung-Ling

    2010-01-01

    The latest researches adopted software technology turning the Nintendo Wii Balance Board into a high performance change of standing posture (CSP) detector, and assessed whether two persons with multiple disabilities would be able to control environmental stimulation using body swing (changing standing posture). This study extends Wii Balance Board functionality for standing posture correction (i.e., actively adjust abnormal standing posture) to assessed whether two persons with multiple disabilities would be able to actively correct their standing posture by controlling their favorite stimulation on/off using a Wii Balance Board with a newly developed standing posture correcting program (SPCP). The study was performed according to an ABAB design, in which A represented baseline and B represented intervention phases. Data showed that both participants significantly increased time duration of maintaining correct standing posture (TDMCSP) to activate the control system to produce environmental stimulation during the intervention phases. Practical and developmental implications of the findings were discussed.

  5. Humor-ing the Local: Multivocal Performance in Stand-Up Comedy in Hawai'i

    ERIC Educational Resources Information Center

    Furukawa, Toshiaki

    2011-01-01

    This dissertation takes a discursive approach to Hawai'i stand-up comedy, which is a highly dramaturgical genre, and it examines the cultural specificity of Hawaii comedy in an explicitly interactional context. This culturally-specific performative genre is a discursive site where comedians and their audiences jointly construct multivocal humor…

  6. Assisting People with Multiple Disabilities Actively Correct Abnormal Standing Posture with a Nintendo Wii Balance Board through Controlling Environmental Stimulation

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Shih, Ching-Tien; Chu, Chiung-Ling

    2010-01-01

    The latest researches adopted software technology turning the Nintendo Wii Balance Board into a high performance change of standing posture (CSP) detector, and assessed whether two persons with multiple disabilities would be able to control environmental stimulation using body swing (changing standing posture). This study extends Wii Balance Board…

  7. In situ coating nickel organic complexes on free-standing nickel wire films for volumetric-energy-dense supercapacitors.

    PubMed

    Hong, Min; Xu, Shusheng; Yao, Lu; Zhou, Chao; Hu, Nantao; Yang, Zhi; Hu, Jing; Zhang, Liying; Zhou, Zhihua; Wei, Hao; Zhang, Yafei

    2018-07-06

    A self-free-standing core-sheath structured hybrid membrane electrodes based on nickel and nickel based metal-organic complexes (Ni@Ni-OC) was designed and constructed for high volumetric supercapacitors. The self-standing Ni@Ni-OC film electrode had a high volumetric specific capacity of 1225.5 C cm -3 at 0.3 A cm -3 and an excellent rate capability. Moreover, when countered with graphene-carbon nanotube (G-CNT) film electrode, the as-assembled Ni@Ni-OC//G-CNT hybrid supercapacitor device delivered an extraordinary volumetric capacitance of 85 F cm -3 at 0.5 A cm -3 and an outstanding energy density of 33.8 at 483 mW cm -3 . Furthermore, the hybrid supercapacitor showed no capacitance loss after 10 000 cycles at 2 A cm -3 , indicating its excellent cycle stability. These fascinating performances can be ascribed to its unique core-sheath structure that high capacity nano-porous nickel based metal-organic complexes (Ni-OC) in situ coated on highly conductive Ni wires. The impressive results presented here may pave the way to construct s self-standing membrane electrode for applications in high volumetric-performance energy storage.

  8. Impaired Postural Control Reduces Sit-to-Stand-to-Sit Performance in Individuals with Chronic Obstructive Pulmonary Disease

    PubMed Central

    Janssens, Lotte; Brumagne, Simon; McConnell, Alison K.; Claeys, Kurt; Pijnenburg, Madelon; Goossens, Nina; Burtin, Chris; Janssens, Wim; Decramer, Marc; Troosters, Thierry

    2014-01-01

    Background Functional activities, such as the sit-to-stand-to-sit (STSTS) task, are often impaired in individuals with chronic obstructive pulmonary disease (COPD). The STSTS task places a high demand on the postural control system, which has been shown to be impaired in individuals with COPD. It remains unknown whether postural control deficits contribute to the decreased STSTS performance in individuals with COPD. Methods Center of pressure displacement was determined in 18 individuals with COPD and 18 age/gender-matched controls during five consecutive STSTS movements with vision occluded. The total duration, as well as the duration of each sit, sit-to-stand, stand and stand-to-sit phase was recorded. Results Individuals with COPD needed significantly more time to perform five consecutive STSTS movements compared to healthy controls (19±6 vs. 13±4 seconds, respectively; p = 0.001). The COPD group exhibited a significantly longer stand phase (p = 0.028) and stand-to-sit phase (p = 0.001) compared to the control group. In contrast, the duration of the sit phase (p = 0.766) and sit-to-stand phase (p = 0.999) was not different between groups. Conclusions Compared to healthy individuals, individuals with COPD needed significantly more time to complete those phases of the STSTS task that require the greatest postural control. These findings support the proposition that suboptimal postural control is an important contributor to the decreased STSTS performance in individuals with COPD. PMID:24533072

  9. Free-standing 3D polyaniline-CNT/Ni-fiber hybrid electrodes for high-performance supercapacitors.

    PubMed

    Li, Yuan; Fang, Yuzhu; Liu, Hong; Wu, Xiaoming; Lu, Yong

    2012-04-28

    Free-standing 3D macroscopic polyaniline (PANi)-carbon nanotube (CNT)-nickel fiber hybrids have been developed, and they deliver high specific capacitance (725 F g(-1) at 0.5 A g(-1)) and high energy density at high rates (~22 W h kg(-1) at 2000 W kg(-1), based on total electrode mass) with good cyclability. This journal is © The Royal Society of Chemistry 2012

  10. A facile synthesis of zinc oxide/multiwalled carbon nanotube nanocomposite lithium ion battery anodes by sol-gel method

    NASA Astrophysics Data System (ADS)

    Köse, Hilal; Karaal, Şeyma; Aydın, Ali Osman; Akbulut, Hatem

    2015-11-01

    Free standing zinc oxide (ZnO) and multiwalled carbon nanotube (MWCNT) nanocomposite materials are prepared by a sol gel technique giving a new high capacity anode material for lithium ion batteries. Free-standing ZnO/MWCNT nanocomposite anodes with two different chelating agent additives, triethanolamine (TEA) and glycerin (GLY), yield different electrochemical performances. Field emission gun scanning electron microscopy (FEG-SEM), energy dispersive X-ray spectrometer (EDS), high resolution transmission electron microscopy (HRTEM) and X-ray diffraction (XRD) analyses reveal the produced anode electrodes exhibit a unique structure of ZnO coating on the MWCNT surfaces. Li-ion cell assembly using a ZnO/MWCNT/GLY free-standing anode and Li metal cathode possesses the best discharge capacity, remaining as high as 460 mAh g-1 after 100 cycles. This core-shell structured anode can offer increased energy storage and performance over conventional anodes in Li-ion batteries.

  11. Forest Stand Segmentation Using Airborne LIDAR Data and Very High Resolution Multispectral Imagery

    NASA Astrophysics Data System (ADS)

    Dechesne, Clément; Mallet, Clément; Le Bris, Arnaud; Gouet, Valérie; Hervieu, Alexandre

    2016-06-01

    Forest stands are the basic units for forest inventory and mapping. Stands are large forested areas (e.g., ≥ 2 ha) of homogeneous tree species composition. The accurate delineation of forest stands is usually performed by visual analysis of human operators on very high resolution (VHR) optical images. This work is highly time consuming and should be automated for scalability purposes. In this paper, a method based on the fusion of airborne laser scanning data (or lidar) and very high resolution multispectral imagery for automatic forest stand delineation and forest land-cover database update is proposed. The multispectral images give access to the tree species whereas 3D lidar point clouds provide geometric information on the trees. Therefore, multi-modal features are computed, both at pixel and object levels. The objects are individual trees extracted from lidar data. A supervised classification is performed at the object level on the computed features in order to coarsely discriminate the existing tree species in the area of interest. The analysis at tree level is particularly relevant since it significantly improves the tree species classification. A probability map is generated through the tree species classification and inserted with the pixel-based features map in an energetical framework. The proposed energy is then minimized using a standard graph-cut method (namely QPBO with α-expansion) in order to produce a segmentation map with a controlled level of details. Comparison with an existing forest land cover database shows that our method provides satisfactory results both in terms of stand labelling and delineation (matching ranges between 94% and 99%).

  12. The front end test stand high performance H- ion source at Rutherford Appleton Laboratory.

    PubMed

    Faircloth, D C; Lawrie, S; Letchford, A P; Gabor, C; Wise, P; Whitehead, M; Wood, T; Westall, M; Findlay, D; Perkins, M; Savage, P J; Lee, D A; Pozimski, J K

    2010-02-01

    The aim of the front end test stand (FETS) project is to demonstrate that chopped low energy beams of high quality can be produced. FETS consists of a 60 mA Penning Surface Plasma Ion Source, a three solenoid low energy beam transport, a 3 MeV radio frequency quadrupole, a chopper, and a comprehensive suite of diagnostics. This paper details the design and initial performance of the ion source and the laser profile measurement system. Beam current, profile, and emittance measurements are shown for different operating conditions.

  13. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies

    NASA Astrophysics Data System (ADS)

    Arunkumar, R.; Hogancamp, Kristina U.; Parsons, Michael S.; Rogers, Donna M.; Norton, Olin P.; Nagel, Brian A.; Alderman, Steven L.; Waggoner, Charles A.

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30×30×29cm3 nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5to12standardm3/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150°C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7standardm3/min, high mass concentrations (˜25mg/m3) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

  14. High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.

    PubMed

    Arunkumar, R; Hogancamp, Kristina U; Parsons, Michael S; Rogers, Donna M; Norton, Olin P; Nagel, Brian A; Alderman, Steven L; Waggoner, Charles A

    2007-08-01

    This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. Relative humidity levels are controllable from 5%-90% and the temperature of the aerosol stream is variable from ambient to 150 degrees C. Test aerosols are produced through spray drying source material solutions that are introduced into a heated stainless steel evaporation chamber through an air-atomizing nozzle. Regulation of the particle size distribution of the aerosol challenge is achieved by varying source solution concentrations and through the use of a postgeneration cyclone. The aerosol generation system is unique in that it facilitates the testing of standard HEPA filters at and beyond rated media velocities by consistently providing, into a nominal flow of 7 standard m(3)/min, high mass concentrations (approximately 25 mg/m(3)) of dry aerosol streams having count mean diameters centered near the most penetrating particle size for HEPA filters (120-160 nm). Aerosol streams that have been generated and characterized include those derived from various concentrations of KCl, NaCl, and sucrose solutions. Additionally, a water insoluble aerosol stream in which the solid component is predominantly iron (III) has been produced. Multiple ports are available on the test stand for making simultaneous aerosol measurements upstream and downstream of the test filter. Types of filter performance related studies that can be performed using this test stand system include filter lifetime studies, filtering efficiency testing, media velocity testing, evaluations under high mass loading and high humidity conditions, and determination of the downstream particle size distributions.

  15. A Performance and Plume Comparison of Xenon and Krypton Propellant on the SPT-100

    DTIC Science & Technology

    2012-07-02

    HET (1.35 kW), performance measurements were made using an inverted pendulum thrust stand. The plume was also characterized by a Faraday probe and RPA...performance reduction for the case of the flight model SPT-100 HET (1.35 kW), per- formance measurements were made using an inverted pendulum thrust stand...where high thrust at reduced specific impulse is advantageous, such as orbit raising missions. Bismuth’s main drawback is that the metal must be

  16. Developments in Test Facility and Data Networking for the Altitude Test Stand at the John C. Stennis Space Center: A General Overview

    NASA Technical Reports Server (NTRS)

    Hebert, Phillip W.

    2008-01-01

    NASA/SSC's Mission in Rocket Propulsion Testing Is to Acquire Test Performance Data for Verification, Validation and Qualification of Propulsion Systems Hardware: Accurate, Reliable, Comprehensive, and Timely. Data Acquisition in a Rocket Propulsion Test Environment Is Challenging: a) Severe Temporal Transient Dynamic Environments; b) Large Thermal Gradients; c) Vacuum to high pressure regimes. A-3 Test Stand Development is equally challenging with respect to accommodating vacuum environment, operation of a CSG system, and a large quantity of data system and control channels to determine proper engine performance as well as Test Stand operation. SSC is currently in the process of providing modernized DAS, Control Systems, Video, and network systems for the A-3 Test Stand to overcome these challenges.

  17. Inflight exercise affects stand test responses after space flight

    NASA Technical Reports Server (NTRS)

    Lee, S. M.; Moore, A. D. Jr; Fritsch-Yelle, J. M.; Greenisen, M. C.; Schneider, S. M.

    1999-01-01

    PURPOSE: The purpose of this study was to determine whether exercise performed by Space Shuttle crew members during short-duration space flights (9-16 d) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 h of landing. METHODS: Thirty crew members performed self-selected inflight exercise and maintained exercise logs to monitor their exercise intensity and duration. Two subjects participated in this investigation during two different flights. A 10-min stand test, preceded by at least 6 min of quiet supine rest, was completed 10-15 d before launch (PRE) and within 4 h of landing (POST). Based upon their inflight exercise records, subjects were grouped as either high (HIex: > or = 3 times/week, HR > or = 70% HRmax, > or = 20 min/session, N = 11), medium (MEDex: > or = 3 times/week, HR < 70% HRmax, > or = 20 min/session, N = 10), or low (LOex: < or = 3 times/week, HR and duration variable, N = 11) exercisers. HR and BP responses to standing were compared between groups (ANOVA, P < or = 0.05). RESULTS: There were no PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared with PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36 +/- 5 bpm) compared with HIex or MEDex groups (25 +/- 1 bpm; 22 +/- 2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after space flight in the MEDex and HIex groups but was significantly greater in the LOex group (PRE: -9 +/- 3; POST: -19 +/- 4 mm Hg). CONCLUSIONS: Thus, moderate to high levels of inflight exercise attenuated HR and PP responses to standing after space flight.

  18. Effect of In-Flight Exercise and Extravehicular Activity on Postflight Stand Tests

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Moore, Alan D., Jr.; Fritsch-Yelle, Janice; Greenisen, Michael; Schneider, Suzanne M.; Foster, Philip P.

    2000-01-01

    The purpose of this study was to determine whether exercise performed by Space Shuttle crewmembers during short-duration spaceflights (9-16 days) affects the heart rate (HR) and blood pressure (BP) responses to standing within 2-4 hr of landing. Thirty crewmembers performed self-selected in-flight exercise and maintained exercise logs to monitor their exercise intensity and duration. A 10min stand test, preceded by at least 6 min of quiet supine rest, was completed 10- 15 d before launch (PRE) and within four hours of landing (POST). Based upon their in-flight exercise records, subjects were grouped as either high (HIex: = 3x/week, HR = 70% ,HRMax, = 20 min/session, n = 11), medium (MEDex: = 3x/week, HR = 70% HRmax, = 20 min/session, n = 10), or low (LOex: = 3x/week, HR and duration variable, n = 11) exercisers. HR and BP responses to standing were compared between groups (ANOVA, or analysis of variance, P < 0.05). There were no PRE differences between the groups in supine or standing HR and BP. Although POST supine HR was similar to PRE, all groups had an increased standing HR compared to PRE. The increase in HR upon standing was significantly greater after flight in the LOex group (36+/-5 bpm) compared to HIex or MEDex groups (25+/-1bpm; 22+/-2 bpm). Similarly, the decrease in pulse pressure (PP) from supine to standing was unchanged after spaceflight in the MEDex and HIex groups, but was significantly less in the LOex group (PRE: -9+/- 3, POST: -19+/- 4 mmHg). Thus, moderate to high levels of in-flight exercise attenuated HR and PP responses to standing after spaceflight compared.

  19. Energy expended and knee joint load accumulated when walking, running, or standing for the same amount of time.

    PubMed

    Miller, Ross H; Edwards, W Brent; Deluzio, Kevin J

    2015-01-01

    Evidence suggests prolonged bouts of sitting are unhealthy, and some public health messages have recently recommended replacing sitting with more standing. However, the relative benefits of replacing sitting with standing compared to locomotion are not known. Specifically, the biomechanical consequences of standing compared to other sitting-alternatives like walking and running are not well known and are usually not considered in studies on sitting. We compared the total knee joint load accumulated (TKJLA) and the total energy expended (TEE) when performing either walking, running, or standing for a common exercise bout duration (30 min). Walking and running both (unsurprisingly) had much more TEE than standing (+300% and +1100%, respectively). TKJLA was similar between walking and standing and 74% greater in running. The results suggest that standing is a poor replacement for walking and running if one wishes to increases energy expenditure, and may be particularly questionable for use in individuals at-risk for knee osteoarthritis due to its surprisingly high TKJLA (just as high as walking, 56% of the load in running) and the type of loading (continuous compression) it places on cartilage. However, standing has health benefits as an "inactivity interrupter" that extend beyond its direct energy expenditure. We suggest that future studies on standing as an inactivity intervention consider the potential biomechanical consequences of standing more often throughout the day, particularly in the case of prolonged bouts of standing. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. A Performance Comparison of Xenon and Krypton Propellant on an SPT-100 Hall Thruster (Preprint)

    DTIC Science & Technology

    2011-08-10

    plume data from electrostatic probes. This paper presents the results of performance measurements made using an inverted pendulum thrust stand. Krypton...inverted pendulum thrust stand. Krypton operating conditions were tested over a large range of operating powers from 800 W to 3.9 kW. Analysis of how...advantages for missions where high thrust at reduced specific impulse is advantageous, primarily for orbit raising missions. Bismuth’s main drawback is

  1. Free-standing 3D polyaniline-CNT/Ni-fiber hybrid electrodes for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Li, Yuan; Fang, Yuzhu; Liu, Hong; Wu, Xiaoming; Lu, Yong

    2012-04-01

    Free-standing 3D macroscopic polyaniline (PANi)-carbon nanotube (CNT)-nickel fiber hybrids have been developed, and they deliver high specific capacitance (725 F g-1 at 0.5 A g-1) and high energy density at high rates (~22 W h kg-1 at 2000 W kg-1, based on total electrode mass) with good cyclability.Free-standing 3D macroscopic polyaniline (PANi)-carbon nanotube (CNT)-nickel fiber hybrids have been developed, and they deliver high specific capacitance (725 F g-1 at 0.5 A g-1) and high energy density at high rates (~22 W h kg-1 at 2000 W kg-1, based on total electrode mass) with good cyclability. Electronic supplementary information (ESI) available: Experimental details on preparation, characterization, and electrochemical testing; Fig. S1-S8, Schemes S1 and S2. See DOI: 10.1039/c2nr30252g

  2. Electrospun N-Doped Porous Carbon Nanofibers Incorporated with NiO Nanoparticles as Free-Standing Film Electrodes for High-Performance Supercapacitors and CO2 Capture.

    PubMed

    Li, Qi; Guo, Jiangna; Xu, Dan; Guo, Jianqiang; Ou, Xu; Hu, Yin; Qi, Haojun; Yan, Feng

    2018-04-01

    Carbon nanofibers (CNF) with a 1D porous structure offer promising support to encapsulate transition-metal oxides in energy storage/conversion relying on their high specific surface area and pore volume. Here, the preparation of NiO nanoparticle-dispersed electrospun N-doped porous CNF (NiO/PCNF) and as free-standing film electrode for high-performance electrochemical supercapacitors is reported. Polyacrylonitrile and nickel acetylacetone are selected as precursors of CNF and Ni sources, respectively. Dicyandiamide not only improves the specific surface area and pore volume, but also increases the N-doping level of PCNF. Benefiting from the synergistic effect between NiO nanoparticles (NPs) and PCNF, the prepared free-standing NiO/PCNF electrodes show a high specific capacitance of 850 F g -1 at a current density of 1 A g -1 in 6 m KOH aqueous solution, good rate capability, as well as excellent long-term cycling stability. Moreover, NiO NPs dispersed in PCNF and large specific surface area provide many electroactive sites, leading to high CO 2 uptake, and high-efficiency CO 2 electroreduction. The synthesis strategy in this study provides a new insight into the design and fabrication of promising multifunctional materials for high-performance supercapacitors and CO 2 electroreduction. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Toward Directly-Deposited Optical Blocking Filters for High-performance, Back-illuminated Imaging X-ray Detectors

    NASA Astrophysics Data System (ADS)

    Bautz, Mark W.; Kissel, S. E.; Ryu, K.; Suntharalingam, V.

    2014-01-01

    Silicon X-ray detectors require optical blocking filters to prevent out-of-band (UV, visible and near-IR) radiation from corrupting the X-ray signal. Traditionally, blocking filters have been deposited on thin, free-standing membranes suspended over the detector. Free-standing filters are fragile, however, and in past instruments have required heavy and complex vacuum housings to protect them from acoustic loads during ground operations and launch. A directly-deposited blocking filter greatly simplifies the instrument and in principle permits better soft X-ray detection efficiency than a traditional free-standing filter. Directly-deposited filters have flown in previous generation instruments (e.g. the XMM/Newton Reflection Grating Spectrometer) but none has yet been demonstrated on a modern, high-performance back-illuminated X-ray CCD. We report here on the status of our NASA-funded Strategic Astrophysics Technology program to demonstrate such filters.

  4. In Situ Synthesis of Vertical Standing Nanosized NiO Encapsulated in Graphene as Electrodes for High-Performance Supercapacitors.

    PubMed

    Lin, Jinghuang; Jia, Henan; Liang, Haoyan; Chen, Shulin; Cai, Yifei; Qi, Junlei; Qu, Chaoqun; Cao, Jian; Fei, Weidong; Feng, Jicai

    2018-03-01

    NiO is a promising electrode material for supercapacitors. Herein, the novel vertically standing nanosized NiO encapsulated in graphene layers (G@NiO) are rationally designed and synthesized as nanosheet arrays. This unique vertical standing structure of G@NiO nanosheet arrays can enlarge the accessible surface area with electrolytes, and has the benefits of short ion diffusion path and good charge transport. Further, an interconnected graphene conductive network acts as binder to encapsulate the nanosized NiO particles as core-shell structure, which can promote the charge transport and maintain the structural stability. Consequently, the optimized G@NiO hybrid electrodes exhibit a remarkably enhanced specific capacity up to 1073 C g -1 and excellent cycling stability. This study provides a facial strategy to design and construct high-performance metal oxides for energy storage.

  5. Digital Analysis of Sit-to-Stand in Masters Athletes, Healthy Old People, and Young Adults Using a Depth Sensor.

    PubMed

    Leightley, Daniel; Yap, Moi Hoon

    2018-03-02

    The aim of this study was to compare the performance between young adults ( n = 15), healthy old people ( n = 10), and masters athletes ( n = 15) using a depth sensor and automated digital assessment framework. Participants were asked to complete a clinically validated assessment of the sit-to-stand technique (five repetitions), which was recorded using a depth sensor. A feature encoding and evaluation framework to assess balance, core, and limb performance using time- and speed-related measurements was applied to markerless motion capture data. The associations between the measurements and participant groups were examined and used to evaluate the assessment framework suitability. The proposed framework could identify phases of sit-to-stand, stability, transition style, and performance between participant groups with a high degree of accuracy. In summary, we found that a depth sensor coupled with the proposed framework could identify performance subtleties between groups.

  6. Digital Analysis of Sit-to-Stand in Masters Athletes, Healthy Old People, and Young Adults Using a Depth Sensor

    PubMed Central

    2018-01-01

    The aim of this study was to compare the performance between young adults (n = 15), healthy old people (n = 10), and masters athletes (n = 15) using a depth sensor and automated digital assessment framework. Participants were asked to complete a clinically validated assessment of the sit-to-stand technique (five repetitions), which was recorded using a depth sensor. A feature encoding and evaluation framework to assess balance, core, and limb performance using time- and speed-related measurements was applied to markerless motion capture data. The associations between the measurements and participant groups were examined and used to evaluate the assessment framework suitability. The proposed framework could identify phases of sit-to-stand, stability, transition style, and performance between participant groups with a high degree of accuracy. In summary, we found that a depth sensor coupled with the proposed framework could identify performance subtleties between groups. PMID:29498644

  7. Effects of sitting versus standing and scanner type on cashiers.

    PubMed

    Lehman, K R; Psihogios, J P; Meulenbroek, R G

    2001-06-10

    In the retail supermarket industry where cashiers perform repetitive, light manual material-handling tasks when scanning and handling products, reports of musculoskeletal disorders and discomfort are high. Ergonomics tradeoffs exist between sitting and standing postures, which are further confounded by the checkstand design and point-of-sale technology, such as the scanner. A laboratory experiment study was conducted to understand the effects of working position (sitting versus standing) and scanner type (bi-optic versus single window) on muscle activity, upper limb and spinal posture, and subjective preference of cashiers. Ten cashiers from a Dutch retailer participated in the study. Cashiers exhibited lower muscle activity in the neck and shoulders when standing and using a bi-optic scanner. Shoulder abduction was also less for standing conditions. In addition, all cashiers preferred using the bi-optic scanner with mixed preferences for sitting (n = 6) and standing (n = 4). Static loading of the muscles was relatively high compared with benchmarks, suggesting that during the task of scanning, cashiers may not have adequate recovery time to prevent fatigue. It is recommended that retailers integrate bi-optic scanners into standing checkstands to minimize postural stress, fatigue and discomfort in cashiers.

  8. 3D graphene nanomaterials for binder-free supercapacitors: scientific design for enhanced performance.

    PubMed

    He, Shuijian; Chen, Wei

    2015-04-28

    Because of the excellent intrinsic properties, especially the strong mechanical strength, extraordinarily high surface area and extremely high conductivity, graphene is deemed as a versatile building block for fabricating functional materials for energy production and storage applications. In this article, the recent progress in the assembly of binder-free and self-standing graphene-based materials, as well as their application in supercapacitors are reviewed, including electrical double layer capacitors, pseudocapacitors, and asymmetric supercapacitors. Various fabrication strategies and the influence of structures on the capacitance performance of 3D graphene-based materials are discussed. We finally give concluding remarks and an outlook on the scientific design of binder-free and self-standing graphene materials for achieving better capacitance performance.

  9. 3D graphene nanomaterials for binder-free supercapacitors: scientific design for enhanced performance

    NASA Astrophysics Data System (ADS)

    He, Shuijian; Chen, Wei

    2015-04-01

    Because of the excellent intrinsic properties, especially the strong mechanical strength, extraordinarily high surface area and extremely high conductivity, graphene is deemed as a versatile building block for fabricating functional materials for energy production and storage applications. In this article, the recent progress in the assembly of binder-free and self-standing graphene-based materials, as well as their application in supercapacitors are reviewed, including electrical double layer capacitors, pseudocapacitors, and asymmetric supercapacitors. Various fabrication strategies and the influence of structures on the capacitance performance of 3D graphene-based materials are discussed. We finally give concluding remarks and an outlook on the scientific design of binder-free and self-standing graphene materials for achieving better capacitance performance.

  10. Semantic segmentation of forest stands of pure species combining airborne lidar data and very high resolution multispectral imagery

    NASA Astrophysics Data System (ADS)

    Dechesne, Clément; Mallet, Clément; Le Bris, Arnaud; Gouet-Brunet, Valérie

    2017-04-01

    Forest stands are the basic units for forest inventory and mapping. Stands are defined as large forested areas (e.g., ⩾ 2 ha) of homogeneous tree species composition and age. Their accurate delineation is usually performed by human operators through visual analysis of very high resolution (VHR) infra-red images. This task is tedious, highly time consuming, and should be automated for scalability and efficient updating purposes. In this paper, a method based on the fusion of airborne lidar data and VHR multispectral images is proposed for the automatic delineation of forest stands containing one dominant species (purity superior to 75%). This is the key preliminary task for forest land-cover database update. The multispectral images give information about the tree species whereas 3D lidar point clouds provide geometric information on the trees and allow their individual extraction. Multi-modal features are computed, both at pixel and object levels: the objects are individual trees extracted from lidar data. A supervised classification is then performed at the object level in order to coarsely discriminate the existing tree species in each area of interest. The classification results are further processed to obtain homogeneous areas with smooth borders by employing an energy minimum framework, where additional constraints are joined to form the energy function. The experimental results show that the proposed method provides very satisfactory results both in terms of stand labeling and delineation (overall accuracy ranges between 84 % and 99 %).

  11. A comparison of sampling methods for a standing tree acoustic device

    Treesearch

    Jerry M. Mahon, Jr.; Lewis Jordan; Lawrence R. Schimleck; Alexander Clark, III; Richard F. Daniels

    2009-01-01

    One method of evaluating potential product performance is the use of acoustic tools for identifying trees with high stiffness. Acoustic velocities for 100 standing loblolly pine (Pinus taeda) trees, obtained with the transmitting and receiving probes placed on the same face and opposite faces, were compared. Significant differences in velocity between the two...

  12. Sit-to-Stand Movement in Children with Cerebral Palsy: A Critical Review

    ERIC Educational Resources Information Center

    dos Santos, Adriana Neves; Pavao, Silvia Leticia; Rocha, Nelci Adriana Cicuto Ferreira

    2011-01-01

    Sit-to-stand (STS) movement is widely performed in daily life and an important pre requisite for acquisition of functional abilities. However, STS is a biomechanical demanding task which requires high levels of neuromuscular coordination, muscle strength and postural control. As children with cerebral palsy (CP) exhibit a series of impairments in…

  13. Simple synthesis of highly catalytic carbon-free MnCo2O4@Ni as an oxygen electrode for rechargeable Li–O2 batteries with long-term stability

    PubMed Central

    Kalubarme, Ramchandra S.; Jadhav, Harsharaj S.; Ngo, Duc Tung; Park, Ga-Eun; Fisher, John G.; Choi, Yun-Il; Ryu, Won-Hee; Park, Chan-Jin

    2015-01-01

    An effective integrated design with a free standing and carbon-free architecture of spinel MnCo2O4 oxide prepared using facile and cost effective hydrothermal method as the oxygen electrode for the Li–O2 battery, is introduced to avoid the parasitic reactions of carbon and binder with discharge products and reaction intermediates, respectively. The highly porous structure of the electrode allows the electrolyte and oxygen to diffuse effectively into the catalytically active sites and hence improve the cell performance. The amorphous Li2O2 will then precipitate and decompose on the surface of free-standing catalyst nanorods. Electrochemical examination demonstrates that the free-standing electrode without carbon support gives the highest specific capacity and the minimum capacity fading among the rechargeable Li–O2 batteries tested. The Li-O2 cell has demonstrated a cyclability of 119 cycles while maintaining a moderate specific capacity of 1000 mAh g−1. Furthermore, the synergistic effect of the fast kinetics of electron transport provided by the free-standing structure and the high electro-catalytic activity of the spinel oxide enables excellent performance of the oxygen electrode for Li-O2 cells. PMID:26292965

  14. Fatigue does not conjointly alter postural and cognitive performance when standing in a shooting position under dual-task conditions.

    PubMed

    Bermejo, José Luis; García-Massó, Xavier; Paillard, Thierry; Noé, Frédéric

    2018-02-01

    This study investigated the effects of fatigue on balance control and cognitive performance in a standing shooting position. Nineteen soldiers were asked to stand while holding a rifle (single task - ST). They also had to perform this postural task while simultaneously completing a cognitive task (dual task - DT). Both the ST and DT were performed in pre- and post-fatigue conditions. In pre-fatigue, participants achieved better balance control in the DT than in the ST, thus suggesting that the increased cognitive activity associated with the DT improves balance control by shifting the attentional focus away from a highly automatised activity. In post-fatigue, balance control was degraded in both the ST and DT, while reaction time was enhanced in the first minutes following the fatiguing exercise without affecting the accuracy of response in the cognitive task, which highlights the relative independent effects of fatigue on balance control and cognitive performance.

  15. Free-standing porous manganese dioxide/graphene composite films for high performance supercapacitors.

    PubMed

    Guo, Wang-Huan; Liu, Teng-Jiao; Jiang, Peng; Zhang, Zhan-Jun

    2015-01-01

    A simple hard template method and hydrothermal process have been employed to fabricate a self-standing hierarchical porous MnO2/graphene film. Thus-constructed electrode materials for binder-free supercapacitors exhibit a high specific capacitance of 266.3 F g(-1) at the density of 0.2 A g(-1). Moreover, the two-electrode device demonstrates an excellent rate capability and cycling stability with capacitance retention of 85.1% after 2000 charge-discharge cycles at a current density of 1 A g(-1). The porous nanostructured design can effectively improve the specific surface areas and account for the shorter relaxation time for the electrodes, resulting in a high electrochemical performance. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Validation of Cardiovascular Parameters During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, Steven H.

    2008-01-01

    Microgravity-induced physiological changes, including cardiovascular deconditioning may impair crewmembers f capabilities during exploration missions on the Moon and Mars. The Functional Task Test (FTT), which will be used to assess task performance in short and long duration astronauts, consists of 7 functional tests to evaluate crewmembers f ability to perform activities to be conducted in a partial-gravity environment or following an emergency landing on Earth. The Recovery from Fall/Stand Test (RFST) tests both the subject fs ability to get up from a prone position and orthostatic intolerance. PURPOSE: Crewmembers have never become presyncopal in the first 3 min of quiet stand, yet it is unknown whether 3 min is long enough to cause similar heart rate fluctuations to a 5-min stand. The purpose of this study was to validate and test the reliability of heart rate variability (HRV) analysis of a 3-min quiet stand. METHODS: To determine the validity of using 3 vs. 5-min of standing to assess HRV, 7 healthy subjects remained in a prone position for 2 min, stood up quickly and stood quietly for 6 min. ECG and continuous blood pressure data were recorded. Mean R-R interval and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the complete FTT on separate days, including the RFST with a 3-min stand test. Analysis of variance (ANOVA) was performed on the HRV measures. RESULTS: Spectral HRV measures reflecting autonomic activity were not different (p>0.05) during the 0-3 and 0-5 min segment (mean R-R interval: 738+/-74 ms, 728+/-69 ms; low frequency to high frequency ratio: 6.5+/-2.2, 7.7+/-2.7; normalized high frequency: 0.19+/-0.03, 0.18+/-0.04). The average coefficient of variation for mean R-R interval, systolic and diastolic blood pressures in the prone position and stand test were less than 8% for the test sessions. ANOVA results yielded a greater inter-subject variability (p.0.006) than inter-session variability (p>0.05) for HRV in the stand test. CONCLUSION: These studies show that a 3 minute stand delivers repeatable cardiovascular heart rate and BP data in the context of this larger series of tests such as the FTT.

  17. Value of the "Standing Test" in the Diagnosis and Evaluation of Beta-blocker Therapy Response in Long QT Syndrome.

    PubMed

    Muñoz-Esparza, Carmen; Zorio, Esther; Domingo Valero, Diana; Peñafiel-Verdú, Pablo; Sánchez-Muñoz, Juan J; García-Molina, Esperanza; Sabater, María; Navarro, Marina; San-Román, Irene; Pérez, Inmaculada; Santos, Juan J; Cabañas-Perianes, Valentín; Valdés, Mariano; Pascual, Domingo; García-Alberola, Arcadio; Gimeno Blanes, Juan R

    2017-11-01

    Patients with congenital long QT syndrome (LQTS) have an abnormal QT adaptation to sudden changes in heart rate provoked by standing. The present study sought to evaluate the standing test in a cohort of LQTS patients and to assess if this QT maladaptation phenomenon is ameliorated by beta-blocker therapy. Electrographic assessments were performed at baseline and immediately after standing in 36 LQTS patients (6 LQT1 [17%], 20 LQT2 [56%], 3 LQT7 [8%], 7 unidentified-genotype patients [19%]) and 41 controls. The corrected QT interval (QTc) was measured at baseline (QTc supine ) and immediately after standing (QTc standing ); the QTc change from baseline (ΔQTc) was calculated as QTc standing - QTc supine . The test was repeated in 26 patients receiving beta-blocker therapy. Both QTc standing and ΔQTc were significantly higher in the LQTS group than in controls (QTc standing , 528 ± 46ms vs 420 ± 15ms, P < .0001; ΔQTc, 78 ± 40ms vs 8 ± 13ms, P < .0001). No significant differences were noted between LQT1 and LQT2 patients. Typical ST-T wave patterns appeared after standing in LQTS patients. Receiver operating characteristic curves of QTc standing and ΔQTc showed a significant increase in diagnostic value compared with the QTc supine (area under the curve for both, 0.99 vs 0.85; P < .001). Beta-blockers attenuated the response to standing in LQTS patients (QTc standing , 440 ± 32ms, P < .0001; ΔQTc, 14 ± 16ms, P < .0001). Evaluation of the QTc after the simple maneuver of standing shows a high diagnostic performance and could be important for monitoring the effects of beta-blocker therapy in LQTS patients. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  18. Integrative Examination of Motor Abilities in Dialysis Patients and Selection of Tests for a Standardized Physical Function Assessment.

    PubMed

    Bučar Pajek, Maja; Leskošek, Bojan; Vivoda, Tjaša; Svilan, Katarina; Čuk, Ivan; Pajek, Jernej

    2016-06-01

    To reduce the need for a large number of executed physical function tests we examined inter-relations and determined predictive power for daily physical activity of the following tests: 6-min walk, 10 repetition sit-to-stand, time up-and-go, Storke balance, handgrip strength, upper limb tapping and sitting forward bend tests. In 90 dialysis and 140 healthy control subjects we found high correlations between all tests, especially those engaging lower extremities. Sit-to-stand, forward bend and handgrip strength were selected for the test battery and composite motor performance score. Sit-to-stand test was superior in terms of sensitivity to uremia effects and association with daily physical function in adjusted analyses. There was no incremental value in calculating the composite performance score. We propose to standardize the physical function assessment of dialysis patients for cross-sectional and longitudinal observations with three simple, cheap, well-accessible and easily performed test tools: sit-to-stand test, handgrip strength and Human Activity Profile questionnaire. © 2016 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  19. Development of a Transient Thrust Stand with Sub-Millisecond Resolution

    NASA Astrophysics Data System (ADS)

    Spells, Corbin Fraser

    The transient thrust stand has been developed to offer 0.1 ms time resolved thrust measurements for the characterization of mono-propellant thrusters for spacecraft applications. Results demonstrated that the system was capable of obtaining dynamic thrust profiles within 5 % and 0.1 ms. Measuring and improving the thrust performance of mono-propellant thrusters will require 1 ms time resolved forces to observe shot-to-shot variations, oscillations, and minimum impulse bits. To date, no thrust stand is capable of measuring up to 22 N forces with a time response of up to 10 kHz. Calibration forces up to 22 N with a frequency response greater than 0.1 ms were obtained using voice coil actuators. Steady state and low frequency measurements were obtained using displacement and velocity sensors and were combined with high frequency vibration modes measured using several accelerometers along the thrust stand arm. The system uses a predictor-based subspace algorithm to obtain a high order state space model of the thrust stand capable of defining the high frequency vibration modes. The high frequency vibration modes are necessary to provide the time response of 0.1 ms. Thruster forces are estimated using an augmented Kalman filter to combine sensor traces from four accelerometers, a velocity sensor, and displacement transducer. Combining low frequency displacement data with high frequency acceleration measurements provides accurate force data across a broad time domain. The transient thrust stand uses a torsional pendulum configuration to minimize influence from external vibration and achieve high force resolution independent of thruster weight.

  20. A Wireless Object Location Detector Enabling People with Developmental Disabilities to Control Environmental Stimulation through Simple Occupational Activities with Nintendo Wii Balance Boards

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Chang, Man-Ling

    2012-01-01

    The latest researches have adopted software technology, turning the Nintendo Wii Balance Board into a high performance standing location detector with a newly developed standing location detection program (SLDP). This study extended SLDP functionality to assess whether two people with developmental disabilities would be able to actively perform…

  1. Hold Firm: Gifted Learners Value Standing One's Ground in Disagreements with a Friend

    ERIC Educational Resources Information Center

    Chichekian, Tanya; Shore, Bruce M.

    2017-01-01

    Seventy-four students in three different Grade 9 classrooms of high-performing learners from the same suburban, comprehensive secondary school, completed a questionnaire focused on their preferences for a friend to stand by his or her position in case of a disagreement, to maintain their own position themselves, and to modify their own stance.…

  2. Thrust stand evaluation of engine performance improvement algorithms in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Conners, Timothy R.

    1992-01-01

    An investigation is underway to determine the benefits of a new propulsion system optimization algorithm in an F-15 airplane. The performance seeking control (PSC) algorithm optimizes the quasi-steady-state performance of an F100 derivative turbofan engine for several modes of operation. The PSC algorithm uses an onboard software engine model that calculates thrust, stall margin, and other unmeasured variables for use in the optimization. As part of the PSC test program, the F-15 aircraft was operated on a horizontal thrust stand. Thrust was measured with highly accurate load cells. The measured thrust was compared to onboard model estimates and to results from posttest performance programs. Thrust changes using the various PSC modes were recorded. Those results were compared to benefits using the less complex highly integrated digital electronic control (HIDEC) algorithm. The PSC maximum thrust mode increased intermediate power thrust by 10 percent. The PSC engine model did very well at estimating measured thrust and closely followed the transients during optimization. Quantitative results from the evaluation of the algorithms and performance calculation models are included with emphasis on measured thrust results. The report presents a description of the PSC system and a discussion of factors affecting the accuracy of the thrust stand load measurements.

  3. Validation of the VitaBit Sit–Stand Tracker: Detecting Sitting, Standing, and Activity Patterns

    PubMed Central

    Plasqui, Guy

    2018-01-01

    Sedentary behavior (SB) has detrimental consequences and cannot be compensated for through moderate-to-vigorous physical activity (PA). In order to understand and mitigate SB, tools for measuring and monitoring SB are essential. While current direct-to-customer wearables focus on PA, the VitaBit validated in this study was developed to focus on SB. It was tested in a laboratory and in a free-living condition, comparing it to direct observation and to a current best-practice device, the ActiGraph, on a minute-by-minute basis. In the laboratory, the VitaBit yielded specificity and negative predictive rates (NPR) of above 91.2% for sitting and standing, while sensitivity and precision ranged from 74.6% to 85.7%. For walking, all performance values exceeded 97.3%. In the free-living condition, the device revealed performance of over 72.6% for sitting with the ActiGraph as criterion. While sensitivity and precision for standing and walking ranged from 48.2% to 68.7%, specificity and NPR exceeded 83.9%. According to the laboratory findings, high performance for sitting, standing, and walking makes the VitaBit eligible for SB monitoring. As the results are not transferrable to daily life activities, a direct observation study in a free-living setting is recommended. PMID:29543766

  4. Relationship between performance variables and baseball ability in youth baseball players.

    PubMed

    Nakata, Hiroki; Nagami, Tomoyuki; Higuchi, Takatoshi; Sakamoto, Kiwako; Kanosue, Kazuyuki

    2013-10-01

    The present study investigated the relationship of performance variables and anthropometric measurements on baseball ability in 164 youth baseball players (age: 6.4-15.7 years). To evaluate their baseball performance, ball speeds in pitching and batting were recorded and kinetic energies of the pitched and hit balls were calculated. To record anthropometric and physical fitness characteristics, height and weight were measured and a battery of physical fitness tests covering standing long jump, side steps, sit-ups, 10-m sprint, trunk flexion, back strength, and grip strengths of both hands were conducted. The results of a multiple regression analysis revealed several significant predictors: age, body mass index (BMI), standing long jump, 10-m sprint, and grip strength for pitched ball kinetic energy and age, BMI, standing long jump, and back strength for hit ball kinetic energy. This study provides scientific evidence that relates certain specific physical performance tests and body characteristics with high achievement in the actual performance of pitching and batting. Youth players, their parents, coaches, and trainers would benefit by addressing these characteristics when planning training programs to improve the baseball performance of youth players.

  5. Free-standing anode of N-doped carbon nanofibers containing SnO{sub x} for high-performance lithium batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zou, Mingzhong; Li, Jiaxin, E-mail: ljx3012982@yahoo.com; Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou 350002

    2014-12-15

    Highlights: • Self-standing SnO{sub x} N-CNF electrodes were synthesized by electrospinning. • The SnO{sub x} N-CNFs anode exhibits high capacity, good cyclic stability, and excellent rate performance for lithium ion batteries. • The enhanced performance is ascribed to the synergetic effects between N-CNFs and SnO{sub x} nanoparticles. - Abstract: Free-standing paper of N-doped carbon nanofibers (NCNFs) containing SnO{sub x} was prepared by electrospinning. The structure and morphology of the sample were analyzed by XRD, XPS, SEM, and TEM. The results show that nitrogen atoms were successfully doped into CNFs. The SnO{sub x} were homogenously embedded in the N-doped CNFs viamore » annealing treatment. Subsequently, the SnO{sub x} NCNF paper was cut into disks and used as anodes for lithium ion batteries (LIBs). The anodes of SnO{sub x} NCNFs exhibit excellent cycling stability and show high capacity of 520 mA h g{sup −1} tested at a 200 mA g{sup −1} after 100 cycles. More importantly, at a high current density of 500 mA g{sup −1}, a large reversible capacity of 430 mA h g{sup −1} after 100 cycles can still be obtained. The good electrochemical performance should be attributed to the good electronic conductivity from the NCNFs and the synergistic effects from NCNFs and SnO{sub x} materials.« less

  6. Taking a Stand: The Effects of Standing Desks on Task Performance and Engagement

    PubMed Central

    Tomiyama, A. Janet; Ward, Andrew

    2017-01-01

    Time spent sitting is associated with negative health outcomes, motivating some individuals to adopt standing desk workstations. This study represents the first investigation of the effects of standing desk use on reading comprehension and creativity. In a counterbalanced, within-subjects design, 96 participants completed reading comprehension and creativity tasks while both sitting and standing. Participants self-reported their mood during the tasks and also responded to measures of expended effort and task difficulty. In addition, participants indicated whether they expected that they would perform better on work-relevant tasks while sitting or standing. Despite participants’ beliefs that they would perform worse on most tasks while standing, body position did not affect reading comprehension or creativity performance, nor did it affect perceptions of effort or difficulty. Mood was also unaffected by position, with a few exceptions: Participants exhibited greater task engagement (i.e., interest, enthusiasm, and alertness) and less comfort while standing rather than sitting. In sum, performance and psychological experience as related to task completion were nearly entirely uninfluenced by acute (~30-min) standing desk use. PMID:28825655

  7. Associations of occupational standing with musculoskeletal symptoms: a systematic review with meta-analysis.

    PubMed

    Coenen, Pieter; Willenberg, Lisa; Parry, Sharon; Shi, Joyce W; Romero, Lorena; Blackwood, Diana M; Maher, Christopher G; Healy, Genevieve N; Dunstan, David W; Straker, Leon M

    2018-02-01

    Given the high exposure to occupational standing in specific occupations, and recent initiatives to encourage intermittent standing among white-collar workers, a better understanding of the potential health consequences of occupational standing is required. We aimed to review and quantify the epidemiological evidence on associations of occupational standing with musculoskeletal symptoms. A systematic review was performed. Data from included articles were extracted and described, and meta-analyses conducted when data were sufficiently homogeneous. Electronic databases were systematically searched. Peer-reviewed articles on occupational standing and musculoskeletal symptoms from epidemiological studies were identified. Of the 11 750 articles screened, 50 articles reporting 49 studies were included (45 cross-sectional and 5 longitudinal; n=88 158 participants) describing the associations of occupational standing with musculoskeletal symptoms, including low-back (39 articles), lower extremity (14 articles) and upper extremity (18 articles) symptoms. In the meta-analysis, 'substantial' (>4 hours/workday) occupational standing was associated with the occurrence of low-back symptoms (pooled OR (95% CI) 1.31 (1.10 to 1.56)). Evidence on lower and upper extremity symptoms was too heterogeneous for meta-analyses. The majority of included studies reported statistically significant detrimental associations of occupational standing with lower extremity, but not with upper extremity symptoms. The evidence suggests that substantial occupational standing is associated with the occurrence of low-back and (inconclusively) lower extremity symptoms, but there may not be such an association with upper extremity symptoms. However, these conclusions are tentative as only limited evidence was found from high-quality, longitudinal studies with fully adjusted models using objective measures of standing. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  8. Aerobic power and peak power of elite America's Cup sailors.

    PubMed

    Neville, Vernon; Pain, Matthew T G; Folland, Jonathan P

    2009-05-01

    Big-boat yacht racing is one of the only able bodied sporting activities where standing arm-cranking ('grinding') is the primary physical activity. However, the physiological capabilities of elite sailors for standing arm-cranking have been largely unreported. The purpose of the study was to assess aerobic parameters, VO(2peak) and onset of blood lactate (OBLA), and anaerobic performance, torque-crank velocity and power-crank velocity relationships and therefore peak power (P (max)) and optimum crank-velocity (omega(opt)), of America's Cup sailors during standing arm-cranking. Thirty-three elite professional sailors performed a step test to exhaustion, and a subset of ten grinders performed maximal 7 s isokinetic sprints at different crank velocities, using a standing arm-crank ergometer. VO(2peak) was 4.7 +/- 0.5 L/min (range 3.6-5.5 L/min) at a power output of 332 +/- 44 W (range 235-425 W). OBLA occurred at a power output of 202 +/- 31 W (61% of W(max)) and VO(2) of 3.3 +/- 0.4 L/min (71% of VO(2peak)). The torque-crank velocity relationship was linear for all participants (r = 0.9 +/- 0.1). P (max) was 1,420 +/- 37 W (range 1,192-1,617 W), and omega(opt) was 125 +/- 6 rpm. These data are among the highest upper-body anaerobic and aerobic power values reported. The unique nature of these athletes, with their high fat-free mass and specific selection and training for standing arm cranking, likely accounts for the high values. The influence of crank velocity on peak power implies that power production during on-board 'grinding' may be optimised through the use of appropriate gear-ratios and the development of efficient gear change mechanisms.

  9. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    PubMed

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  10. Longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury.

    PubMed

    Triolo, Ronald J; Bailey, Stephanie Nogan; Miller, Michael E; Rohde, Loretta M; Anderson, James S; Davis, John A; Abbas, James J; DiPonio, Lisa A; Forrest, George P; Gater, David R; Yang, Lynda J

    2012-05-01

    To investigate the longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury. Case series. Research or outpatient physical therapy departments of 4 academic hospitals. Subjects (N=15) with thoracic or low cervical level spinal cord injuries who had received the 8-channel neuroprosthesis for exercise and standing. After completing rehabilitation with the device, the subjects were discharged to unrestricted home use of the system. A series of assessments were performed before discharge and at a follow-up appointment approximately 1 year later. Neuroprosthesis usage, maximum standing time, body weight support, knee strength, knee fatigue index, electrode stability, and component survivability. Levels of maximum standing time, body weight support, knee strength, and knee fatigue index were not statistically different from discharge to follow-up (P>.05). Additionally, neuroprosthesis usage was consistent with subjects choosing to use the system on approximately half of the days during each monitoring period. Although the number of hours using the neuroprosthesis remained constant, subjects shifted their usage to more functional standing versus more maintenance exercise, suggesting that the subjects incorporated the neuroprosthesis into their lives. Safety and reliability of the system were demonstrated by electrode stability and a high component survivability rate (>90%). This group of 15 subjects is the largest cohort of implanted lower-extremity neuroprosthetic exercise and standing system users. The safety and efficiency data from this group, and acceptance of the neuroprosthesis as demonstrated by continued usage, indicate that future efforts toward commercialization of a similar device may be warranted. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Developing custom fire behavior fuel models from ecologically complex fuel structures for upper Atlantic Coastal Plain forests.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parresol, Bernard, R.; Scott, Joe, H.; Andreu, Anne

    2012-01-01

    Currently geospatial fire behavior analyses are performed with an array of fire behavior modeling systems such as FARSITE, FlamMap, and the Large Fire Simulation System. These systems currently require standard or customized surface fire behavior fuel models as inputs that are often assigned through remote sensing information. The ability to handle hundreds or thousands of measured surface fuelbeds representing the fine scale variation in fire behavior on the landscape is constrained in terms of creating compatible custom fire behavior fuel models. In this study, we demonstrate an objective method for taking ecologically complex fuelbeds from inventory observations and converting thosemore » into a set of custom fuel models that can be mapped to the original landscape. We use an original set of 629 fuel inventory plots measured on an 80,000 ha contiguous landscape in the upper Atlantic Coastal Plain of the southeastern United States. From models linking stand conditions to component fuel loads, we impute fuelbeds for over 6000 stands. These imputed fuelbeds were then converted to fire behavior parameters under extreme fuel moisture and wind conditions (97th percentile) using the fuel characteristic classification system (FCCS) to estimate surface fire rate of spread, surface fire flame length, shrub layer reaction intensity (heat load), non-woody layer reaction intensity, woody layer reaction intensity, and litter-lichen-moss layer reaction intensity. We performed hierarchical cluster analysis of the stands based on the values of the fire behavior parameters. The resulting 7 clusters were the basis for the development of 7 custom fire behavior fuel models from the cluster centroids that were calibrated against the FCCS point data for wind and fuel moisture. The latter process resulted in calibration against flame length as it was difficult to obtain a simultaneous calibration against both rate of spread and flame length. The clusters based on FCCS fire behavior parameters represent reasonably identifiable stand conditions, being: (1) pine dominated stands with more litter and down woody debriscomponents than other stands, (2) hardwood and pine stands with no shrubs, (3) hardwood dominated stands with low shrub and high non-woody biomass and high down woody debris, (4) stands with high grass and forb (i.e., non-woody) biomass as well as substantial shrub biomass, (5) stands with both high shrub and litter biomass, (6) pine-mixed hardwood stands with moderate litter biomass and low shrub biomass, and (7) baldcypress-tupelo stands. Models representing these stand clusters generated flame lengths from 0.6 to 2.3 musing a 30 km h{sub 1} wind speed and fireline intensities of 100-1500 kW m{sub 1} that are typical within the range of experience on this landscape. The fuel models ranked 1 < 2 < 7 < 5 < 4 < 3 < 6 in terms of both flame length and fireline intensity. The method allows for ecologically complex data to be utilized in order to create a landscape representative of measured fuel conditions and to create models that interface with geospatial fire models.« less

  12. Miniaturized spectrometer for stand-off chemical detection

    NASA Astrophysics Data System (ADS)

    Henning, Patrick F.; Chadha, Suneet; Damren, Richard; Rowe, Rebecca C.; Stevenson, Chuck; Curtiss, Lawrence E.; DiGiuseppe, Thomas G.

    2002-02-01

    Advanced autonomous detection of both chemical warfare agents and toxic industrial chemicals has long been of major military concern and is becoming an increasingly realistic need. Foster-Miller has successfully designed and demonstrated a high spectral throughput monolithic wedge spectrometer capable of providing early, stand-off detection of chemical threats. Recent breakthrough innovations in IR source technologies, high D* multispectral array detectors, and IR waveguide materials has allowed for the development of a robust, miniature, monolithic infrared spectrometer. Foster-Miller recently demonstrated a high resolution spectrometer operating in the 8 to 12 micron region for chemical agent detection. Results will be presented demonstrating the feasibility of adapting the wedge spectrometer to operate as an upward looking ground sensor for stand-off chemical detection. Our miniaturized spectrometer forms the basis for deploying low cost, lightweight sensors which may be used for reconnaissance missions or delivered to remote locations for unattended operation. The ability of perform passive stand-off infrared chemical agent and chemical emissions detection with a low cost, compact device that can operate autonomously in remote environments has broad applications in both the military and commercial marketplace.

  13. Mapping of past stand-level forest disturbances and estimation of time since disturbance using simulated spaceborne LiDAR data

    NASA Astrophysics Data System (ADS)

    Sanchez Lopez, N.; Hudak, A. T.; Boschetti, L.

    2017-12-01

    Explicit information on the location, the size or the time since disturbance (TSD) at the forest stand level complements field inventories, improves the monitoring of forest attributes and the estimation of biomass and carbon stocks. Even-aged stands display homogenous structural parameters that have often been used as a proxy of stand age. Consequently, performing object-oriented analysis on Light Detection and Ranging (LiDAR) data has potential to detect historical stand-replacing disturbances. Recent research has shown good results in the delineation of forest stands as well as in the prediction of disturbance occurrence and TSD using airborne LiDAR data. Nevertheless, the use of airborne LiDAR for systematic monitoring of forest stands is limited by the sporadic availability of data and its high cost compared to satellite instruments. NASA's forthcoming Global Ecosystem Dynamics Investigations (GEDI) mission will provide systematically data on the vertical structure of the vegetation, but its use presents some challenges compared to the common discrete-return airborne LiDAR. GEDI will be a waveform instrument, hence the summary metrics will be different to those obtained with airborne LiDAR, and the sampling configuration could limit the utility of the data, especially on heterogeneous landscapes. The potential use of GEDI data for forest characterization at the stand level would therefore depend on the predictive power of the GEDI footprint metrics, and on the density of point samples relative to forest stand size (i.e. the number of observation/footprints per stand).In this study, we assess the performance of simulated GEDI-derived metrics for stand characterization and estimation of TSD, and the point density needed to adequately identify forest stands, which translates - due to the fixed sampling configuration - into the minimum temporal interval needed to collect a sufficient number of points. The study area was located in the Clear Creek, Selway River, and Elk Creek watersheds ( 54,000 ha) within the Nez Perce-Clearwater National Forest in Idaho, where airborne LiDAR and reference maps on TSD were available. Simulated GEDI footprints and waveforms were obtained from airborne LiDAR point clouds and the results were compared to similar analysis performed with airborne LiDAR.

  14. A flexible, gigahertz, and free-standing thin film piezoelectric MEMS resonator with high figure of merit

    NASA Astrophysics Data System (ADS)

    Jiang, Yuan; Zhang, Menglun; Duan, Xuexin; Zhang, Hao; Pang, Wei

    2017-07-01

    In this paper, a 2.6 GHz air-gap type thin film piezoelectric MEMS resonator was fabricated on a flexible polyethylene terephthalate film. A fabrication process combining transfer printing and hot-embossing was adopted to form a free-standing structure. The flexible radio frequency MEMS resonator possesses a quality factor of 946 and an effective coupling coefficient of 5.10%, and retains its high performance at a substrate bending radius of 1 cm. The achieved performance is comparable to that of conventional resonators on rigid silicon wafers. Our demonstration provides a viable approach to realizing universal MEMS devices on flexible polymer substrates, which is of great significance for building future fully integrated and multi-functional wireless flexible electronic systems.

  15. Impact of Fibromyalgia in the Sit-to-Stand-to-Sit Performance Compared With Healthy Controls.

    PubMed

    Collado-Mateo, Daniel; Adsuar, Jose C; Dominguez-Muñoz, Francisco J; Olivares, Pedro R; Gusi, Narcis

    2017-06-01

    Fibromyalgia is associated with a reduction in the ability to perform activities of daily living. Sit-to-stand-to-sit performance is one of the most common activities of daily living and often is evaluated by counting the number of repetitions of the 30-second chair-stand test. No study, however, has examined the performance over the 30 seconds of this test of female patients with fibromyalgia on a phase-by-phase basis. To evaluate the impact of fibromyalgia on performance of the 30-second chair-stand test and to analyze how the kinematic performance changed over the 30-second test period. A cross-sectional study. Local association of fibromyalgia. Fifteen females with fibromyalgia and nine healthy female controls. Participants performed the 30-second chair-stand test while wearing a motion capture device. Duration of each sit-to-stand-to-sit phase within the 30-second time limit was compared between groups using repeated measures analysis of variance. The association between duration of phases and scores from the revised version of the Fibromyalgia Impact Questionnaire was tested using bivariate correlations. The duration of impulse and sit-to-stand phases were gradually increased over the 30 seconds of the chair-stand test for women with fibromyalgia compared with healthy controls (P = .04 and P = .02, respectively). The mean duration of these 2 phases was associated with symptom duration and the function domain of the revised version of the Fibromyalgia Impact Questionnaire (P < .05). Also, stiffness was directly associated with the duration of the stand-up phase (P = .04). Kinematic performance during the 30-second chair-stand test differed between women with fibromyalgia and healthy controls. Since sit-to-stand from a chair is a common daily activity, women with fibromyalgia may require specific exercises to improve performance of this task. Not applicable. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Using laser altimetry-based segmentation to refine automated tree identification in managed forests of the Black Hills, South Dakota

    Treesearch

    Eric Rowell; Carl Selelstad; Lee Vierling; Lloyd Queen; Wayne Sheppard

    2006-01-01

    The success of a local maximum (LM) tree detection algorithm for detecting individual trees from lidar data depends on stand conditions that are often highly variable. A laser height variance and percent canopy cover (PCC) classification is used to segment the landscape by stand condition prior to stem detection. We test the performance of the LM algorithm using canopy...

  17. Effect of bed height and use of hands on trunk angular velocity during the sit-to-stand transfer.

    PubMed

    Lindemann, Ulrich; van Oosten, Leon; Evers, Jordi; Becker, Clemens; van Dieen, Jaap H; van Lummel, Rob C

    2014-01-01

    The ability to rise from a chair or bed is critical to an individual's quality of life because it determines functional independence. This study was to investigate the effect of bed height and use of hands on trunk angular velocity and trunk angles during the sit-to-stand (STS) performance. Twenty-four older persons (median age 74 years) were equipped with a body-fixed gyroscopic sensor and stood up from a bed adjusted to different heights, with and without the use of hands at each height. Peak angular velocity and trunk range of motion decreased with increasing bed height (all p ≤ 0.038) and were lower using hands during STS transfer indicating less effort. In conclusion, gyroscopic sensor data of the STS transfer of older persons show differences as an effect of bed height and use of hands. These results provide the rationale for recommending a relatively high bed height for most of the older persons. To minimise the effort during sit-to-stand transfer performance from bed, it is necessary to understand the effect of bed height and use of hands. It is concluded that a relatively high bed height and the use of hands is helpful for most of the older persons during sit-to-stand transfer.

  18. Use of the color trails test as an embedded measure of performance validity.

    PubMed

    Henry, George K; Algina, James

    2013-01-01

    One hundred personal injury litigants and disability claimants referred for a forensic neuropsychological evaluation were administered both portions of the Color Trails Test (CTT) as part of a more comprehensive battery of standardized tests. Subjects who failed two or more free-standing tests of cognitive performance validity formed the Failed Performance Validity (FPV) group, while subjects who passed all free-standing performance validity measures were assigned to the Passed Performance Validity (PPV) group. A cutscore of ≥45 seconds to complete Color Trails 1 (CT1) was associated with a classification accuracy of 78%, good sensitivity (66%) and high specificity (90%), while a cutscore of ≥84 seconds to complete Color Trails 2 (CT2) was associated with a classification accuracy of 82%, good sensitivity (74%) and high specificity (90%). A CT1 cutscore of ≥58 seconds, and a CT2 cutscore ≥100 seconds was associated with 100% positive predictive power at base rates from 20 to 50%.

  19. Low intensity vibration of ankle muscles improves balance in elderly persons at high risk of falling

    PubMed Central

    Toosizadeh, Nima; Mohler, Jane

    2018-01-01

    In our study we examined postural performance of young healthy persons (HY), elderly healthy persons (HE), and elderly persons at high risk of falling (FR). Anterio-posterior (AP) and medio-lateral (ML) ankle and hip angular deviations, as well as linear displacements of the center of mass (COM) were assessed in persons standing with eyes either open or closed, while none, and 40 and 30 Hz vibrations were applied bilaterally to the ankle muscle gastrocnemius. During quiet standing with eyes open, balance parameters in FR group differed from those in healthy groups. ML ankle and hip angular deviations, as well as COM linear displacements were noticeably larger in FR group. During quiet standing with eyes closed, all balance parameters in participants of all groups had a clear trend to increase. During standing with eyes open, 40 Hz vibration increased all but one balance parameter within HY group, ankle angular deviations in HE group, but none in FR group. In response to 30 Hz vibration, only ankle angular deviations and COM linear displacements increased in HY group. There were no changes in both elderly groups. During standing with eyes closed, 40 and 30 Hz vibrations did not produce consistent changes in balance parameters in HY and HE groups. In FR persons, 40 Hz vibration did not change balance parameters. However, in FR groups, 30 Hz vibration decreased ankle and hip angular deviations, and COM linear displacements. The major result of the study is a finding that low intensity vibration of ankle muscles makes balance better in elderly persons at high risk of falling. This result is clinically relevant because it suggests that applying mild vibration to ankle muscles while standing and walking might benefit elderly persons, improving their postural performance and reducing a risk of unexpected falls. PMID:29579098

  20. Design and characterization of a torque-controllable actuator for knee assistance during sit-to-stand.

    PubMed

    Shepherd, Max K; Rouse, Elliott J

    2016-08-01

    Individuals with post-stroke hemiparesis often have difficulty standing out of a chair. One way to potentially improve sit-to-stand is to provide knee extension assistance using a powered knee exoskeleton. An exoskeleton providing unilateral, partial assistance during sit-to-stand would need to be torque-controllable. There are no knee exoskeletons on the market suitable for conducting experiments assisting stroke patients with sit-to-stand, so to enable such experiments a research device was developed. The purpose of this report is to present the design of a novel knee exoskeleton actuator that uses a fiberglass leaf spring in series to improve torque-controllability, and present a characterization of the actuator performance. The actuator is capable of the required torque and speed for sit-to-stand, has high bandwidth (25 Hz), low output impedance at low frequencies (<;0.5 Nm), and excellent torque tracking. An orthotic brace built upon this actuator will enable an in-depth study on the biomechanical effects of providing stroke subjects with knee extension assistance during sit-to-stand.

  1. Standing wave performance test of IDT-SAW transducer prepared by silk-screen printing

    NASA Astrophysics Data System (ADS)

    Wang, Ziping; Jiang, Zhengxuan; Chen, Liangbin; Li, Yefei; Li, Meixia; Wang, Shaohan

    2018-05-01

    With the advantages of high performance and low loss, interdigital surface acoustic wave (IDT-SAW) transducers are widely used in the fields of nondestructive testing, communication and broadcasting. The production, performance and application of surface acoustic wave (SAW) actuators has become a research hotspot. Based on the basic principle of SAW, an IDT-SAW transducer is designed and fabricated using silk-screen printing in this work. The experiment results show that in terms of SAW performance, the fabricated IDT-SAW transducer can generate standing wave fields comparable to those generated using traditional fabrication methods. The resonant frequency response of the IDT-SAW transducer and SAW attenuation coefficient were obtained by experiments. It has provided a method to test the transducer sensing performance by using fabricated IDT-SAW transducer.

  2. Posture and performance: sitting vs. standing for security screening.

    PubMed

    Drury, C G; Hsiao, Y L; Joseph, C; Joshi, S; Lapp, J; Pennathur, P R

    2008-03-01

    A classification of the literature on the effects of workplace posture on performance of different mental tasks showed few consistent patterns. A parallel classification of the complementary effect of performance on postural variables gave similar results. Because of a lack of data for signal detection tasks, an experiment was performed using 12 experienced security operators performing an X-ray baggage-screening task with three different workplace arrangements. The current workplace, sitting on a high chair viewing a screen placed on top of the X-ray machine, was compared to a standing workplace and a conventional desk-sitting workplace. No performance effects of workplace posture were found, although the experiment was able to measure performance effects of learning and body part discomfort effects of workplace posture. There are implications for the classification of posture and performance and for the justification of ergonomics improvements based on performance increases.

  3. Wafer-size free-standing single-crystalline graphene device arrays

    NASA Astrophysics Data System (ADS)

    Li, Peng; Jing, Gaoshan; Zhang, Bo; Sando, Shota; Cui, Tianhong

    2014-08-01

    We report an approach of wafer-scale addressable single-crystalline graphene (SCG) arrays growth by using pre-patterned seeds to control the nucleation. The growth mechanism and superb properties of SCG were studied. Large array of free-standing SCG devices were realized. Characterization of SCG as nano switches shows excellent performance with life time (>22 000 times) two orders longer than that of other graphene nano switches reported so far. This work not only shows the possibility of producing wafer-scale high quality SCG device arrays but also explores the superb performance of SCG as nano devices.

  4. Correlation of Space Shuttle Landing Performance with Post-Flight Cardiovascular Dysfunction

    NASA Technical Reports Server (NTRS)

    McCluskey, R.

    2004-01-01

    Introduction: Microgravity induces cardiovascular adaptations resulting in orthostatic intolerance on re-exposure to normal gravity. Orthostasis could interfere with performance of complex tasks during the re-entry phase of Shuttle landings. This study correlated measures of Shuttle landing performance with post-flight indicators of orthostatic intolerance. Methods: Relevant Shuttle landing performance parameters routinely recorded at touchdown by NASA included downrange and crossrange distances, airspeed, and vertical speed. Measures of cardiovascular changes were calculated from operational stand tests performed in the immediate post-flight period on mission commanders from STS-41 to STS-66. Stand test data analyzed included maximum standing heart rate, mean increase in maximum heart rate, minimum standing systolic blood pressure, and mean decrease in standing systolic blood pressure. Pearson correlation coefficients were calculated with the null hypothesis that there was no statistically significant linear correlation between stand test results and Shuttle landing performance. A correlation coefficient? 0.5 with a p<0.05 was considered significant. Results: There were no significant linear correlations between landing performance and measures of post-flight cardiovascular dysfunction. Discussion: There was no evidence that post-flight cardiovascular stand test data correlated with Shuttle landing performance. This implies that variations in landing performance were not due to space flight-induced orthostatic intolerance.

  5. Continuous fabrication of a MnS/Co nanofibrous air electrode for wide integration of rechargeable zinc-air batteries.

    PubMed

    Wang, Yang; Fu, Jing; Zhang, Yining; Li, Matthew; Hassan, Fathy Mohamed; Li, Guang; Chen, Zhongwei

    2017-10-26

    Exploring highly efficient bifunctional electrocatalysts toward the oxygen reduction and evolution reactions is essential for the realization of high-performance rechargeable zinc-air batteries. Herein, a novel nanofibrous bifunctional electrocatalyst film, consisting of metallic manganese sulfide and cobalt encapsulated by nitrogen-doped carbon nanofibers (CMS/NCNF), is prepared through a continuous electrospinning method followed by carbonization treatment. The CMS/NCNF bifunctional catalyst shows both comparable ORR and OER performances to those of commercial precious metal-based catalysts. Furthermore, the free-standing CMS/NCNF fibrous thin film is directly used as the air electrode in a solid-state zinc-air battery, which exhibits superior flexibility while retaining stable battery performance at different bending angles. This study provides a versatile design route for the rational design of free-standing bifunctional catalysts for direct use as the air electrode in rechargeable zinc-air batteries.

  6. Cardiopulmonary, blood and peritoneal fluid alterations associated with abdominal insufflation of carbon dioxide in standing horses.

    PubMed

    Latimer, F G; Eades, S C; Pettifer, G; Tetens, J; Hosgood, G; Moore, R M

    2003-05-01

    Abdominal insufflation is performed routinely during laparoscopy in horses to improve visualisation and facilitate instrument and visceral manipulations during surgery. It has been shown that high-pressure pneumoperitoneum with carbon dioxide (CO2) has deleterious cardiopulmonary effects in dorsally recumbent, mechanically ventilated, halothane-anaesthetised horses. There is no information on the effects of CO2 pneumoperitoneum on cardiopulmonary function and haematology, plasma chemistry and peritoneal fluid (PF) variables in standing sedated horses during laparoscopic surgery. To determine the effects of high pressure CO2 pneumoperitoneum in standing sedated horses on cardiopulmonary function, blood gas, haematology, plasma chemistry and PF variables. Six healthy, mature horses were sedated with an i.v. bolus of detomidine (0.02 mg/kg bwt) and butorphanol (0.02 mg/kg bwt) and instrumented to determine the changes in cardiopulmonary function, haematology, serum chemistry and PF values during and after pneumoperitoneum with CO2 to 15 mmHg pressure for standing laparoscopy. Each horse was assigned at random to either a standing left flank exploratory laparoscopy (LFL) with CO2 pneumoperitoneum or sham procedure (SLFL) without insufflation, and instrumented for measurement of cardiopulmonary variables. Each horse underwent a second procedure in crossover fashion one month later so that all 6 horses had both an LFL and SLFL performed. Cardiopulmonary variables and blood gas analyses were obtained 5 mins after sedation and every 15 mins during 60 mins baseline (BL), insufflation (15 mmHg) and desufflation. Haematology, serum chemistry analysis and PF analysis were performed at BL, insufflation and desufflation, and 24 h after the conclusion of each procedure. Significant decreases in heart rate, cardiac output and cardiac index and significant increases in mean right atrial pressure, systemic vascular resistance and pulmonary vascular resistance were recorded immediately after and during sedation in both groups of horses. Pneumoperitoneum with CO2 at 15 mmHg had no significant effect on cardiopulmonary function during surgery. There were no significant differences in blood gas, haematology or plasma chemistry values within or between groups at any time interval during the study. There was a significant increase in the PF total nucleated cell count 24 h following LFL compared to baseline values for LFL or SLFL at 24 h. There were no differences in PF protein concentrations within or between groups at any time interval. Pneumoperitoneum with CO2 during standing laparoscopy in healthy horses does not cause adverse alterations in cardiopulmonary, haematology or plasma chemistry variables, but does induce a mild inflammatory response within the peritoneal cavity. High pressure (15 mmHg) pneumoperitoneum in standing sedated mature horses for laparoscopic surgery can be performed safely without any short-term or cumulative adverse effects on haemodynamic or cardiopulmonary function.

  7. Fabrication of free-standing copper foils covered with highly-ordered copper nanowire arrays

    NASA Astrophysics Data System (ADS)

    Zaraska, Leszek; Sulka, Grzegorz D.; Jaskuła, Marian

    2012-07-01

    The through-hole nanoporous anodic aluminum oxide (AAO) membranes with relatively large surface area (ca. 2 cm2) were employed for fabrication of free-standing and mechanically stable copper foils covered with close-packed and highly-ordered copper nanowire arrays. The home-made AAO membranes with different pore diameters and interpore distances were fabricated via a two-step self-organized anodization of aluminum performed in sulfuric acid, oxalic acid and phosphoric acid followed by the pore opening/widening procedure. The direct current (DC) electrodeposition of copper was performed efficiently on both sides of AAO templates. The bottom side of the AAO templates was not insulated and consequently Cu nanowire arrays on thick Cu layers were obtained. The proposed template-assisted fabrication of free-standing copper nanowire array electrodes is a promising method for synthesis of nanostructured current collectors. The composition of Cu nanowires was confirmed by energy dispersive X-Ray spectroscopy (EDS) and X-ray diffraction (XRD) analyses. The structural features of nanowires were evaluated from field emission scanning electron microscopy (FE-SEM) images and compared with the characteristic parameters of anodic alumina membranes.

  8. Effects of standing on typing task performance and upper limb discomfort, vascular and muscular indicators.

    PubMed

    Fedorowich, Larissa M; Côté, Julie N

    2018-10-01

    Standing is a popular alternative to traditionally seated computer work. However, no studies have described how standing impacts both upper body muscular and vascular outcomes during a computer typing task. Twenty healthy adults completed two 90-min simulated work sessions, seated or standing. Upper limb discomfort, electromyography (EMG) from eight upper body muscles, typing performance and neck/shoulder and forearm blood flow were collected. Results showed significantly less upper body discomfort and higher typing speed during standing. Lower Trapezius EMG amplitude was higher during standing, but this postural difference decreased with time (interaction effect), and its variability was 68% higher during standing compared to sitting. There were no effects on blood flow. Results suggest that standing computer work may engage shoulder girdle stabilizers while reducing discomfort and improving performance. Studies are needed to identify how standing affects more complex computer tasks over longer work bouts in symptomatic workers. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Acute effects on cognitive performance following bouts of standing and light-intensity physical activity in a simulated workplace environment.

    PubMed

    Mullane, Sarah L; Buman, Matthew P; Zeigler, Zachary S; Crespo, Noe C; Gaesser, Glenn A

    2017-05-01

    To compare acute cognitive effects following bouts of standing (STAND), cycling (CYCLE) and walking (WALK) to a sit-only (SIT) condition. Randomized cross-over full-factorial study. Nine overweight (BMI=29±3kg/m 2 ) adults (30±15years; 7 females, 2 males) completed four conditions (SIT, STAND, WALK and CYCLE) across a 6h period with a 7days washout period between conditions. SIT consisted of uninterrupted sitting. Experimental conditions included intermittent bouts of standing (STAND), cycling (CYCLE) and walking (WALK). A cognitive performance battery (Cogstate) was completed twice in a seated position following bouts of standing and light-intensity physical activity. Mixed-effects models compared between-condition differences in standardized score (z-score), accuracy (%), and speed (log10ms). Cognitive performance z-score and accuracy measures were higher during STAND, CYCLE and WALK (P<0.05) conditions compared to the SIT condition. CYCLE was better than other experimental conditions. Compared to uninterrupted sitting, short bouts of standing or light-intensity cycling and walking may improve acute cognitive performance. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Accuracy of recumbent height measurement.

    PubMed

    Gray, D S; Crider, J B; Kelley, C; Dickinson, L C

    1985-01-01

    Since many patients requiring specialized nutritional support are bedridden, measurement of height for purposes of nutritional assessment or prescription must often be done with the patient in bed. This study examined the accuracy of measuring body height in bed in the supine position. Two measurements were performed on 108 ambulatory inpatients: (1) standing height using a standard height-weight scale, and (2) bed height using a flexible tape. Patients were divided into four groups based on which of two researchers performed each of the two measurements. Each patient was also weighed and self-reported height, weight, sex, and age were recorded. Bed height was significantly longer than standing height by 3.68 cm, but the two measurements were equally precise. It was believed, however, that this 2% difference was probably not clinically significant in most circumstances. Bed height correlated highly with standing height (r = 0.95), and the regression equation was standing height = 13.82 +/- 0.09 bed height. Patients overestimated their heights. Heights recorded by nurses were more accurate when patients were measured than when asked about their heights, but the patients were more often asked than measured.

  11. Stand for testing the electrical race car engine

    NASA Astrophysics Data System (ADS)

    Baier, M.; Franiasz, J.; Mierzwa, P.; Wylenzek, D.

    2015-11-01

    An engine test stand created especially for research of electrical race car is described in the paper. The car is an aim of Silesian Greenpower project whose participants build and test electrical vehicles to take part in international races in Great Britain. The engine test stand is used to test and measure the characteristics of vehicles and their engines. It has been designed particularly to test the electric cars engineered by students of Silesian Greenpower project. The article contains a description how the test stand works and shows its versatility in many areas. The paper presents both construction of the test stand, control system and sample results of conducted research. The engine test stand was designed and modified using PLM Siemens NX 8.5. The construction of the test stand is highly modular, which means it can be used both for testing the vehicle itself or for tests without the vehicle. The test stand has its own wheel, motor, powertrain and braking system with second engine. Such solution enables verifying various concepts without changing the construction of the vehicle. The control system and measurement system are realized by enabling National Instruments product myRIO (RIO - Reconfigurable Input/Output). This controller in combination with powerful LabVIEW environment performs as an advanced tool to control torque and speed simultaneously. It is crucial as far as the test stand is equipped in two motors - the one being tested and the braking one. The feedback loop is realized by an optical encoder cooperating with the rotor mounted on the wheel. The results of tests are shown live on the screen both as a chart and as single values. After performing several tests there is a report generated. The engine test stand is widely used during process of the Silesian Greenpower vehicle design. Its versatility enables powertrain testing, wheels and tires tests, thermal analysis and more.

  12. The Relationship of Reduced Peripheral Nerve Function and Diabetes With Physical Performance in Older White and Black Adults

    PubMed Central

    Strotmeyer, Elsa S.; de Rekeneire, Nathalie; Schwartz, Ann V.; Faulkner, Kimberly A.; Resnick, Helaine E.; Goodpaster, Bret H.; Shorr, Ronald I.; Vinik, Aaron I.; Harris, Tamara B.; Newman, Anne B.

    2008-01-01

    OBJECTIVE—Poor peripheral nerve function is prevalent in diabetes and older populations, and it has great potential to contribute to poor physical performance. RESEARCH DESIGN AND METHODS—Cross-sectional analyses were done for the Health, Aging, and Body Composition (Health ABC) Study participants (n = 2,364; 48% men; 38% black; aged 73–82 years). Sensory and motor peripheral nerve function in legs/feet was assessed by 10- and 1.4-g monofilament perception, vibration detection, and peroneal motor nerve conduction amplitude and velocity. The Health ABC lower-extremity performance battery was a supplemented version of the Established Populations for the Epidemiologic Studies of the Elderly battery (chair stands, standing balance, and 6-m walk), adding increased stand duration, single foot stand, and narrow walk. RESULTS—Diabetic participants had fewer chair stands (0.34 vs. 0.36 stands/s), shorter standing balance time (0.69 vs. 0.75 ratio), slower usual walking speed (1.11 vs. 1.14 m/s), slower narrow walking speed (0.80 vs. 0.90 m/s), and lower performance battery score (6.43 vs. 6.93) (all P < 0.05). Peripheral nerve function was associated with each physical performance measure independently. After addition of peripheral nerve function in fully adjusted models, diabetes remained significantly related to a lower performance battery score and slower narrow walking speed but not to chair stands, standing balance, or usual walking speed. CONCLUSIONS—Poor peripheral nerve function accounts for a portion of worse physical performance in diabetes and may be directly associated with physical performance in older diabetic and nondiabetic adults. The impact of peripheral nerve function on incident disability should be evaluated in older adults. PMID:18535192

  13. Porous MoO2 nanowires as stable and high-rate negative electrodes for electrochemical capacitors.

    PubMed

    Zheng, Dezhou; Feng, Haobin; Zhang, Xiyue; He, Xinjun; Yu, Minghao; Lu, Xihong; Tong, Yexiang

    2017-04-04

    Free-standing porous MoO 2 nanowires with extraordinary capacitive performance are developed as high-performance electrodes for electrochemical capacitors. The as-obtained MoO 2 electrode exhibits a remarkable capacitance of 424.4 mF cm -2 with excellent electrochemical durability (no capacitance decay after 10 000 cycles at various scan rates).

  14. NASA's Functional Task Test: High Intensity Exercise Improves the Heart Rate Response to a Stand Test Following 70 Days of Bedrest

    NASA Technical Reports Server (NTRS)

    Laurie, Steven S.; Lee, Stuart M. C.; Phillips, Tiffany R.; Dillon, E. Lichar; Sheffield-Moore, Melinda; Urban, Randall J.; Ploutz-Snyder, Lori; Stenger, Michael B.; Bloomberg, Jacob J.

    2015-01-01

    Cardiovascular adaptations due to spaceflight are modeled with 6deg head-down tilt bed rest (BR) and result in decreased orthostatic tolerance. We investigated if high-intensity resistive and aerobic exercise with and without testosterone supplementation would improve the heart rate (HR) response to a 3.5-min stand test and how quickly these changes recovered following BR. During 70 days of BR male subjects performed no exercise (Control, n=10), high intensity supine resistive and aerobic exercise (Exercise, n=9), or supine exercise plus supplemental testosterone (Exercise+T, n=8; 100 mg i.m., weekly in 2-week on/off cycles). We measured HR for 2 min while subjects were prone and for 3 min after standing twice before and 0, 1, 6, and 11 days after BR. Mixed-effects linear regression models were used to evaluate group, time, and interaction effects. Compared to pre-bed rest, prone HR was elevated on BR+0 and BR+1 in Control, but not Exercise or Exercise+T groups, and standing HR was greater in all 3 groups. The increase in prone and standing HR in Control subjects was greater than either Exercise or Exercise+T groups and all groups recovered by BR+6. The change in HR from prone to standing more than doubled on BR+0 in all groups, but was significantly less in the Exericse+T group compared to the Control, but not Exercise group. Exercise reduces, but does not prevent the increase in HR observed in response to standing. The significantly lower HR response in the Exercise+T group requires further investigation to determine physiologic significance.

  15. The Innovative Design and Prototype Verification of Wheelchair with One Degree of Freedom to Perform Lifting and Standing Functions

    NASA Astrophysics Data System (ADS)

    Hsieh, Long-Chang; Chen, Tzu-Hsia

    2017-12-01

    Traditionally, the mechanism of wheelchair with lifting and standing functions has 2 degrees of freedom, and used 2 power sources to perform these 2 motion function. The purpose of this paper is to invent new wheelchair with 1 degree of freedom to perform these 2 motion functions. Hence, we can use only 1 power source to drive the mechanism to achieve lifting and standing motion functions. The new design has the advantages of simple operation, more stability, and more safety. For traditional standing wheelchair, its’ centre of gravity moves forward when standing up and it needs 2 auxiliary wheels to prevent dumping. In this paper, by using the checklist method of Osborn, the wheelchair with 1 DOF is invented to perform lifting and standing functions. The centre of gravity of this new wheelchair after standing up still located between the front and rear wheels, no auxiliary wheels needed. Finally, the prototype is manufactured to verify the theoretical results.

  16. PubMed Central

    VANNI, S.; CASATI, C.; MORONI, F.; RISSO, M.; OTTAVIANI, M.; NAZERIAN, P.; GRIFONI, S.; VANNUCCHI, P.

    2014-01-01

    SUMMARY Vertigo is generally due to a benign disorder, but it is the most common symptom associated with misdiagnosis of stroke. In this pilot study, we preliminarily assessed the diagnostic performance of a structured bedside algorithm to differentiate central from non-central acute vertigo (AV). Adult patients presenting to a single Emergency Department with vertigo were evaluated with STANDING (SponTAneous Nystagmus, Direction, head Impulse test, standiNG) by one of five trained emergency physicians or evaluated ordinarily by the rest of the medical staff (control group). The gold standard was a complete audiologic evaluation by a clinicians who are experts in assessing dizzy patients and neuroimaging. Reliability, sensibility and specificity of STANDING were calculated. Moreover, to evaluate the potential clinical impact of STANDING, neuroimaging and hospitalisation rates were compared with control group. A total of 292 patients were included, and 48 (16.4%) had a diagnosis of central AV. Ninety-eight (33.4%) patients were evaluated with STANDING. The test had good interobserver agreement (k = 0.76), with very high sensitivity (100%, 95%CI 72.3-100%) and specificity (94.3%, 95%CI 90.7-94.3%). Furthermore, hospitalisation and neuroimaging test rates were lower in the STANDING than in the control group (27.6% vs. 50.5% and 31.6% vs. 71.1%, respectively). In conclusion, STANDING seems to be a promising simple structured bedside algorithm that in this preliminary study identified central AV with a very high sensitivity, and was associated with significant reduction of neuroimaging and hospitalisation rates. PMID:25762835

  17. Quasi-free-standing bilayer epitaxial graphene field-effect transistors on 4H-SiC (0001) substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, C.; Li, J.; Song, X. B.

    2016-01-04

    Quasi-free-standing epitaxial graphene grown on wide band gap semiconductor SiC demonstrates high carrier mobility and good material uniformity, which make it promising for graphene-based electronic devices. In this work, quasi-free-standing bilayer epitaxial graphene is prepared and its transistors with gate lengths of 100 nm and 200 nm are fabricated and characterized. The 100 nm gate length graphene transistor shows improved DC and RF performances including a maximum current density I{sub ds} of 4.2 A/mm, and a peak transconductance g{sub m} of 2880 mS/mm. Intrinsic current-gain cutoff frequency f{sub T} of 407 GHz is obtained. The exciting DC and RF performances obtained in the quasi-free-standingmore » bilayer epitaxial graphene transistor show the great application potential of this material system.« less

  18. Assisting children with attention deficit hyperactivity disorder to reduce the hyperactive behavior of arbitrary standing in class with a Nintendo Wii remote controller through an active reminder and preferred reward stimulation.

    PubMed

    Shih, Ching-Hsiang; Wang, Shu-Hui; Wang, Yun-Ting

    2014-09-01

    Recent studies in the field of special education have shown that in combination with software technology, high-tech commercial products can be applied as useful assistive technology devices to help people with disabilities. This study extended this concept to turn a Nintendo Wii Remote Controller into a high-performance limb action detector, in order to evaluate whether two students with Attention Deficit Hyperactivity Disorder (ADHD) could reduce their hyperactive behavior through an active reminder and stimulation in the form of the participants' preferred rewards. This study focused on one particular hyperactive behavior common to both students: standing up arbitrarily during class. The active reminder was in the form of vibration feedback provided via the built-in function of the Wii Remote Controller, which was controlled and triggered by a control system to remind participants when they were engaging in standing behavior. This study was performed according to a multiple baseline design across participants. The results showed that both participants significantly improved their control over their hyperactive behavior during the intervention phase, and retained this effective performance in the maintenance phase. The practical and developmental implications of the findings are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Semantic Segmentation of Forest Stands of Pure Species as a Global Optimization Problem

    NASA Astrophysics Data System (ADS)

    Dechesne, C.; Mallet, C.; Le Bris, A.; Gouet-Brunet, V.

    2017-05-01

    Forest stand delineation is a fundamental task for forest management purposes, that is still mainly manually performed through visual inspection of geospatial (very) high spatial resolution images. Stand detection has been barely addressed in the literature which has mainly focused, in forested environments, on individual tree extraction and tree species classification. From a methodological point of view, stand detection can be considered as a semantic segmentation problem. It offers two advantages. First, one can retrieve the dominant tree species per segment. Secondly, one can benefit from existing low-level tree species label maps from the literature as a basis for high-level object extraction. Thus, the semantic segmentation issue becomes a regularization issue in a weakly structured environment and can be formulated in an energetical framework. This papers aims at investigating which regularization strategies of the literature are the most adapted to delineate and classify forest stands of pure species. Both airborne lidar point clouds and multispectral very high spatial resolution images are integrated for that purpose. The local methods (such as filtering and probabilistic relaxation) are not adapted for such problem since the increase of the classification accuracy is below 5%. The global methods, based on an energy model, tend to be more efficient with an accuracy gain up to 15%. The segmentation results using such models have an accuracy ranging from 96% to 99%.

  20. Bilayer free-standing beam splitter for Fourier transform infrared spectrometry.

    PubMed

    Rowell, N L; Wang, E A

    1996-06-01

    We describe the design, fabrication, testing, and performance of a two-layer free-standing beam splitter for use in far-infrared Fourier transform infrared spectrometers. This bilayer beam splitter, consisting of a low-index polymer layer in combination with a high-index semiconductor layer, has an efficiency that is higher than that of the best combination of four single-layer Mylar beam splitters currently in use for spectrometry from 50 to 550 cm(-1).

  1. School Furniture Dimensions: Standing and Reaching.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    Performance of school children in regard to their standing and reach postures are described with dimensions given on the limits of their performance only. The facts of task performances are presented for the following tasks--(1) seeing into a shelf, (2) reaching into a shelf, (3) drawing on a vertical surface, (4) sitting or standing while…

  2. Makers of the United States Air Force,

    DTIC Science & Technology

    1987-01-01

    in a larger percentage of high performance , large capacity bombers. . ... In every test or exercise we have ever had . .. this plane stands out head...believed large formations of heavily armed, high - performance B-17Es could succeed, but a serious effort should be made to develop escort fighters. No...multi-engined bombers: one with high speed , substantial firepower, and short range; the other, a long-range bomber with heavy load capacity. In the summer

  3. Laboratories | Energy Systems Integration Facility | NREL

    Science.gov Websites

    laboratories to be safely divided into multiple test stand locations (or "capability hubs") to enable Fabrication Laboratory Energy Systems High-Pressure Test Laboratory Energy Systems Integration Laboratory Energy Systems Sensor Laboratory Fuel Cell Development and Test Laboratory High-Performance Computing

  4. Doping and controllable pore size enhanced electrochemical performance of free-standing 3D graphene films

    NASA Astrophysics Data System (ADS)

    Wang, Liping; Qin, Kaiqiang; Li, Jiajun; Zhao, Naiqin; Shi, Chunsheng; Ma, Liying; He, Chunnian; He, Fang; Liu, Enzuo

    2018-01-01

    High quality free-standing 3D nanoporous graphene (3DNG) films were fabricated using nanoporous nickel as template and catalyst. The effect of heteroatom doping and pore size on the electrochemical performance of the 3D graphene films as supercapacitor electrodes are systematically studied. Compared with macroporous graphene films, nanoporous graphene films exhibit an extraordinarily large operational window in neutral, acidic and alkaline aqueous electrolytes, as well as high packing density. Nitrogen and oxygen doping play different roles in different aqueous electrolytes on the electrical conductivity and pseudocapacitance of 3DNG. The realization of both high packing density, 3.65 mg/cm2, and the maximum working window, as well as the synergistic effect between N and O doping, gives rise to a high areal capacitance of 435 mF/cm2 in neutral electrolyte and excellent cycle stability up to 5000 cycles. The results provide a potential strategy to further increase the volumetric or areal energy density of carbon-based aqueous supercapacitor.

  5. The Utility of the Supine-to-Stand Test as a Measure of Functional Motor Competence in Children Aged 5–9 Years

    PubMed Central

    Duncan, Michael J.; Lawson, Chelsey; Walker, Leanne Jaye; Stodden, David; Eyre, Emma L. J.

    2017-01-01

    This study examined how supine-to-stand (STS) performance is related to process and product assessment of motor competence (MC) in children. Ninety-one children aged 5–9 years were assessed for process and product MC (10 m running speed and standing long jump) as well as process and product measures of STS. Tertiles were created for STS process and STS product scores to create 3 groups reflecting low, medium, and high STS competency. ANCOVA analysis, controlling for age, for process STS, indicated that process MC was significantly higher in children, classified as medium STS (p = 0.048) and high STS (p = 0.011) competence, and that 10 m run speed was slower for low STS compared to medium (p = 0.019) and high STS (p = 0.004). For product STS tertiles, process MC was significantly higher for children in the lowest (fastest) STS tertile compared to those in the medium highest (slowest) tertile (p = 0.01). PMID:29910427

  6. Investigating the performance of LiDAR-derived biomass information in hydromechanic slope stability modelling

    NASA Astrophysics Data System (ADS)

    Schmaltz, Elmar; Steger, Stefan; Bogaard, Thom; Van Beek, Rens; Glade, Thomas

    2017-04-01

    Hydromechanic slope stability models are often used to assess the landslide susceptibility of hillslopes. Some of these models are able to account for vegetation related effects when assessing slope stability. However, spatial information of required vegetation parameters (especially of woodland) that are defined by land cover type, tree species and stand density are mostly underrepresented compared to hydropedological and geomechanical parameters. The aim of this study is to assess how LiDAR-derived biomass information can help to distinguish distinct tree stand-immanent properties (e.g. stand density and diversity) and further improve the performance of hydromechanic slope stability models. We used spatial vegetation data produced from sophisticated algorithms that are able to separate single trees within a stand based on LiDAR point clouds and thus allow an extraordinary detailed determination of the aboveground biomass. Further, this information is used to estimate the species- and stand-related distribution of the subsurface biomass using an innovative approach to approximate root system architecture and development. The hydrological tree-soil interactions and their impact on the geotechnical stability of the soil mantle are then reproduced in the dynamic and spatially distributed slope stability model STARWARS/PROBSTAB. This study highlights first advances in the approximation of biomechanical reinforcement potential of tree root systems in tree stands. Based on our findings, we address the advantages and limitations of highly detailed biomass information in hydromechanic modelling and physically based slope failure prediction.

  7. Free-Standing Hybrid Graphene Paper Encapsulating Nanostructures for High Cycle-Life Supercapacitors.

    PubMed

    Jiao, Xinyan; Hao, Qingli; Xia, Xifeng; Lei, Wu; Ouyang, Yu; Ye, Haitao; Mandler, Daniel

    2018-03-09

    The incorporation of spacers between graphene sheets has been investigated as an effective method to improve the electrochemical performance of graphene papers (GPs) for supercapacitors. Here, we report the design of free-standing GP@NiO and GP@Ni hybrid GPs in which NiO nanoclusters and Ni nanoparticles are encapsulated into graphene sheets through electrostatic assembly and subsequent vacuum filtration. The encapsulated NiO nanoclusters and Ni nanoparticles can mitigate the restacking of graphene sheets, providing sufficient spaces for high-speed ion diffusion and electron transport. In addition, the spacers strongly bind to graphene sheets, which can efficiently improve the electrochemical stability. Therefore, at a current density of 0.5 A g -1 , the GP@NiO and GP@Ni electrodes exhibit higher specific capacitances of 306.9 and 246.1 F g -1 than the GP electrode (185.7 F g -1 ). The GP@NiO and GP@Ni electrodes exhibit capacitance retention of 98.7 % and 95.6 % after 10000 cycles, demonstrating an outstanding cycling stability. Additionally, the GP@NiO∥GP@Ni delivers excellent cycling stability (93.7 % after 10 000 cycles) and high energy density. These free-standing encapsulated hybrid GPs have great potential as electrode for high-performance supercapacitors. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. A novel application of PageRank and user preference algorithms for assessing the relative performance of track athletes in competition.

    PubMed

    Beggs, Clive B; Shepherd, Simon J; Emmonds, Stacey; Jones, Ben

    2017-01-01

    Ranking enables coaches, sporting authorities, and pundits to determine the relative performance of individual athletes and teams in comparison to their peers. While ranking is relatively straightforward in sports that employ traditional leagues, it is more difficult in sports where competition is fragmented (e.g. athletics, boxing, etc.), with not all competitors competing against each other. In such situations, complex points systems are often employed to rank athletes. However, these systems have the inherent weakness that they frequently rely on subjective assessments in order to gauge the calibre of the competitors involved. Here we show how two Internet derived algorithms, the PageRank (PR) and user preference (UP) algorithms, when utilised with a simple 'who beat who' matrix, can be used to accurately rank track athletes, avoiding the need for subjective assessment. We applied the PR and UP algorithms to the 2015 IAAF Diamond League men's 100m competition and compared their performance with the Keener, Colley and Massey ranking algorithms. The top five places computed by the PR and UP algorithms, and the Diamond League '2016' points system were all identical, with the Kendall's tau distance between the PR standings and '2016' points system standings being just 15, indicating that only 5.9% of pairs differed in their order between these two lists. By comparison, the UP and '2016' standings displayed a less strong relationship, with a tau distance of 95, indicating that 37.6% of the pairs differed in their order. When compared with the standings produced using the Keener, Colley and Massey algorithms, the PR standings appeared to be closest to the Keener standings (tau distance = 67, 26.5% pair order disagreement), whereas the UP standings were more similar to the Colley and Massey standings, with the tau distances between these ranking lists being only 48 (19.0% pair order disagreement) and 59 (23.3% pair order disagreement) respectively. In particular, the UP algorithm ranked 'one-off' victors more highly than the PR algorithm, suggesting that the UP algorithm captures alternative characteristics to the PR algorithm, which may more suitable for predicting future performance in say knockout tournaments, rather than for use in competitions such as the Diamond League. As such, these Internet derived algorithms appear to have considerable potential for objectively assessing the relative performance of track athletes, without the need for complicated points equivalence tables. Importantly, because both algorithms utilise a 'who beat who' model, they automatically adjust for the strength of the competition, thus avoiding the need for subjective decision making.

  9. Free-Standing Air Cathodes Based on 3D Hierarchically Porous Carbon Membranes: Kinetic Overpotential of Continuous Macropores in Li-O2 Batteries.

    PubMed

    Xu, Shu-Mao; Liang, Xiao; Ren, Zhi-Chu; Wang, Kai-Xue; Chen, Jie-Sheng

    2018-06-04

    Free-standing macroporous air electrodes with enhanced interfacial contact, rapid mass transport, and tailored deposition space for large amounts of Li 2 O 2 are essential for improving the rate performance of Li-O 2 batteries. An ordered mesoporous carbon membrane with continuous macroporous channels was prepared by inversely topological transformation from ZnO nanorod array. Utilized as a free-standing air cathode for Li-O 2 battery, the hierarchically porous carbon membrane shows superior rate performance. However, the increased cross-sectional area of the continuous macropores on the cathode surface leads to a kinetic overpotential with large voltage hysteresis and linear voltage variation against Butler-Volmer behavior. The kinetics were investigated based on the rate-determining step of second electron transfer accompanied by migration of Li + in solid or quasi-solid intermediates. These discoveries shed light on the design of the air cathode for Li-O 2 batteries with high-rate performance. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Free-standing ultrathin CoMn2O4 nanosheets anchored on reduced graphene oxide for high-performance supercapacitors.

    PubMed

    Gao, Guoxin; Lu, Shiyao; Xiang, Yang; Dong, Bitao; Yan, Wei; Ding, Shujiang

    2015-11-21

    Ultrathin CoMn2O4 nanosheets supported on reduced graphene oxide (rGO) are successfully synthesized through a simple co-precipitation method with a post-annealing treatment. With the assistance of citrate, the free-standing CoMn2O4 ultrathin nanosheets can form porous overlays on both sides of the rGO sheets. Such a novel hybrid nanostructure can effectively promote charge transport and accommodate volume variation upon prolonged charge/discharge cycling. When evaluated as a promising electrode for supercapacitors in a 6 M KOH solution electrolyte, the hybrid nanocomposites demonstrate highly enhanced capacitance and excellent cycling stability.

  11. Electrospinning preparation of oxygen-deficient nano TiO2-x/carbon fibre membrane as a self-standing high performance anode for Li-ion batteries

    PubMed Central

    Li, Jing-quan; Han, Chong; Yao, Shan-shan; Zhang, Ji; Zhai, Hong-ai; Chen, Li-li; Shen, Xiang-qian; Xiao, Ke-song

    2017-01-01

    Improving the specific capacity and electronic conductivity of TiO2 can boost its practical application as a promising anode material for lithium ion batteries. In this work, a three-dimensional networking oxygen-deficient nano TiO2-x/carbon fibre membrane was achieved by combining the electrospinning process with a hot-press sintering method and directly used as a self-standing anode. With the synergistic effects of three-dimensional conductive networks, surface oxygen deficiency, high specific surface area and high porosity, binder-free and self-standing structure, etc., the nano TiO2-x/carbon fibre membrane electrode displays a high electrochemical reaction kinetics and a high specific capacity. The reversible capacity could be jointly generated from porous carbon, full-lithiation of TiO2 and interfacial lithium storage. At a current density of 100 mA g−1, the reversible discharge capacity can reach 464 mA h g−1. Even at 500 mA g−1, the discharge capacity still remains at 312 mA h g−1. Compared with pure carbon fibre and TiO2 powder, the TiO2-x/C fibre membrane electrode also exhibits an excellent cycle performance with a discharge capacity of 209 mA h g−1 after 700 cycles at the current density of 300 mA g−1, and the coulombic efficiency always remains at approximately 100%. PMID:28791160

  12. Electrospinning preparation of oxygen-deficient nano TiO2-x/carbon fibre membrane as a self-standing high performance anode for Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Jing, Mao-xiang; Li, Jing-quan; Han, Chong; Yao, Shan-shan; Zhang, Ji; Zhai, Hong-ai; Chen, Li-li; Shen, Xiang-qian; Xiao, Ke-song

    2017-07-01

    Improving the specific capacity and electronic conductivity of TiO2 can boost its practical application as a promising anode material for lithium ion batteries. In this work, a three-dimensional networking oxygen-deficient nano TiO2-x/carbon fibre membrane was achieved by combining the electrospinning process with a hot-press sintering method and directly used as a self-standing anode. With the synergistic effects of three-dimensional conductive networks, surface oxygen deficiency, high specific surface area and high porosity, binder-free and self-standing structure, etc., the nano TiO2-x/carbon fibre membrane electrode displays a high electrochemical reaction kinetics and a high specific capacity. The reversible capacity could be jointly generated from porous carbon, full-lithiation of TiO2 and interfacial lithium storage. At a current density of 100 mA g-1, the reversible discharge capacity can reach 464 mA h g-1. Even at 500 mA g-1, the discharge capacity still remains at 312 mA h g-1. Compared with pure carbon fibre and TiO2 powder, the TiO2-x/C fibre membrane electrode also exhibits an excellent cycle performance with a discharge capacity of 209 mA h g-1 after 700 cycles at the current density of 300 mA g-1, and the coulombic efficiency always remains at approximately 100%.

  13. Effects of unipedal standing balance exercise on the prevention of falls and hip fracture among clinically defined high-risk elderly individuals: a randomized controlled trial.

    PubMed

    Sakamoto, Keizo; Nakamura, Toshitaka; Hagino, Hiroshi; Endo, Naoto; Mori, Satoshi; Muto, Yoshiteru; Harada, Atsushi; Nakano, Tetsuo; Itoi, Eiji; Yoshimura, Mitsuo; Norimatsu, Hiromichi; Yamamoto, Hiroshi; Ochi, Takahiro

    2006-10-01

    The aim of this study was to assess the effectiveness of the unipedal standing balance exercise for 1 min to prevent falls and hip fractures in high-risk elderly individuals with a randomized controlled trial. This control study was designed as a 6-month intervention trial. Subjects included 553 clinically defined high-risk adults who were living in residences or in the community. They were randomized to an exercise group and a control group. Randomization to the subjects was performed by a table of random numbers. A unipedal standing balance exercise with open eyes was performed by standing on each leg for 1 min three times per day. As a rule, subjects of the exercise group stood on one leg without holding onto any support, but unstable subjects were permitted to hold onto a bar during the exercise time. Falls and hip fractures were reported by nurses, physical therapists, or facility staff with a survey sheet every month. This survey sheet was required every month for both groups. Registered subjects were 553 persons ranging in age from 37 to 102 years (average, 81.6 years of age). Twenty-six subjects dropped out. The number of falls and hip fractures for the 6-month period after the trial for 527 of the 553 subjects for whom related data were available were assessed. The exercise group comprised 315 subjects and the control group included 212 subjects. The cumulative number of falls of the exercise group, with 1 multiple faller omitted, was 118, and the control group recorded 121 falls. A significant intergroup difference was observed. However, the cumulative number of hip fractures was only 1 case in both groups. This difference was not statistically significant. The unipedal standing balance exercise is effective to prevent falls but was not shown to be statistically significant in the prevention of hip fracture in this study.

  14. Standing enucleation in the horse: A report of 5 cases

    PubMed Central

    Hewes, Christina A.; Keoughan, G. Curry; Gutierrez–Nibeyro, Santiago

    2007-01-01

    Enucleation was performed in 5 horses under local anesthesia and sedation with the horse standing. Minimal hemorrhage occurred during the surgical procedure, and there were no other reported complications. Standing enucleation is a surgery that is safe to perform in horses. PMID:17542371

  15. Design and implementation of a crystal collimation test stand at the Large Hadron Collider

    NASA Astrophysics Data System (ADS)

    Mirarchi, D.; Hall, G.; Redaelli, S.; Scandale, W.

    2017-06-01

    Future upgrades of the CERN Large Hadron Collider (LHC) demand improved cleaning performance of its collimation system. Very efficient collimation is required during regular operations at high intensities, because even a small amount of energy deposited on superconducting magnets can cause an abrupt loss of superconducting conditions (quench). The possibility to use a crystal-based collimation system represents an option for improving both cleaning performance and impedance compared to the present system. Before relying on crystal collimation for the LHC, a demonstration under LHC conditions (energy, beam parameters, etc.) and a comparison against the present system is considered mandatory. Thus, a prototype crystal collimation system has been designed and installed in the LHC during the Long Shutdown 1 (LS1), to perform feasibility tests during the Run 2 at energies up to 6.5 TeV. The layout is suitable for operation with proton as well as heavy ion beams. In this paper, the design constraints and the solutions proposed for this test stand for feasibility demonstration of crystal collimation at the LHC are presented. The expected cleaning performance achievable with this test stand, as assessed in simulations, is presented and compared to that of the present LHC collimation system. The first experimental observation of crystal channeling in the LHC at the record beam energy of 6.5 TeV has been obtained in 2015 using the layout presented (Scandale et al., Phys Lett B 758:129, 2016). First tests to measure the cleaning performance of this test stand have been carried out in 2016 and the detailed data analysis is still on-going.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bonachea, Dan; Hargrove, P.

    GASNet is a language-independent, low-level networking layer that provides network-independent, high-performance communication primitives tailored for implementing parallel global address space SPMD languages and libraries such as UPC, UPC++, Co-Array Fortran, Legion, Chapel, and many others. The interface is primarily intended as a compilation target and for use by runtime library writers (as opposed to end users), and the primary goals are high performance, interface portability, and expressiveness. GASNet stands for "Global-Address Space Networking".

  17. Free-standing Fe2O3 nanomembranes enabling ultra-long cycling life and high rate capability for Li-ion batteries.

    PubMed

    Liu, Xianghong; Si, Wenping; Zhang, Jun; Sun, Xiaolei; Deng, Junwen; Baunack, Stefan; Oswald, Steffen; Liu, Lifeng; Yan, Chenglin; Schmidt, Oliver G

    2014-12-12

    With Fe2O3 as a proof-of-concept, free-standing nanomembrane structure is demonstrated to be highly advantageous to improve the performance of Li-ion batteries. The Fe2O3 nanomembrane electrodes exhibit ultra-long cycling life at high current rates with satisfactory capacity (808 mAh g(-1) after 1000 cycles at 2 C and 530 mAh g(-1) after 3000 cycles at 6 C) as well as repeatable high rate capability up to 50 C. The excellent performance benefits particularly from the unique structural advantages of the nanomembranes. The mechanical feature can buffer the strain of lithiation/delithiation to postpone the pulverization. The two-dimensional transport pathways in between the nanomembranes can promote the pseudo-capacitive type storage. The parallel-laid nanomembranes, which are coated by polymeric gel-like film and SEI layer with the electrolyte in between layers, electrochemically behave like numerous "mini-capacitors" to provide the pseudo-capacitance thus maintain the capacity at high rate.

  18. Investigation of postural hypotension due to static prolonged standing in female workers.

    PubMed

    Kabe, Isamu; Tsuruoka, Hiroko; Tokujitani, Yoko; Endo, Yuichi; Furusawa, Mami; Takebayashi, Toru

    2007-07-01

    The "Just-in-Time system" improves productivity and efficiency through cost reduction while it makes workers work in a standing posture. The aim of this study was to investigate the prevalence of postural hypotension in females during prolonged standing work, and to discuss preventive methods. Twelve female static standing workers (mean age+/-standard deviation; 32+/-14 yr old), 6 male static standing workers (30+/-4 yr old), 10 female walking workers (27+/-7 yr old) and 9 female desk workers (31+/-5 yr old) in a certain telecommunications equipment manufacturing factory agreed to participate in this study. All participants received an interview with an occupational physician, and performed the standing up test before working and ambulatory blood pressure monitoring (ABPM) while working. Although the blood pressure of the standing up test did not differ among the groups, mean pulse rates on standing up significantly increased in every group. Hypotension rates in the female standing workers' group by ABPM were 9 persons of 12 participants (75%) for systolic blood pressure (SBP), and were 11 persons of 12 participants (92%) for diastolic blood pressure (DBP). There were significantly higher than those in the female desk workers' group, none of 9 participants (0%) for SBP and 2 of 9 participants (22%) for DBP. The hypotension rates both male standing and female walking worker groups did not differ. Because all 8 workers who were found to have postural hypotension by the standing up test had decreased SBP and/or DBP by ABPM, it is suggested that persons at high risk of postural hypotension during standing work could be screened by the standing up test. The mechanism of postural hypotension may be a decrease of venous return due to leg swelling, and neurocardiogenic or vasovagal response. Preventing the congestion of the lower limbs by walking, managing standing time and wearing elastic hose to keep the amount of the venous return could prevent postural hypotension during prolonged standing work.

  19. Identification of Left Atrial Appendage Thrombi in Patients With Persistent and Long-Standing Persistent Atrial Fibrillation Using Intra-Cardiac Echocardiography and Cardiac Computed Tomography.

    PubMed

    Ikegami, Yukinori; Tanimoto, Kojiro; Inagawa, Kohei; Shiraishi, Yasuyuki; Fuse, Jun; Sakamoto, Munehisa; Momiyama, Yukihiko; Takatsuki, Seiji

    2017-12-25

    Intracardiac echocardiography (ICE) and cardiac computed tomography (CCT), in addition to standard transesophageal echocardiography (TEE), have been used to identify left atrial (LA) thrombi prior to ablation for atrial fibrillation (AF). The clinical advantages of this, however, remain unclear. This study therefore investigated the advantages of additional pre-procedural LA appendage (LAA) thrombus evaluation using ICE and the clinical value of CCT in persistent and long-standing persistent AF.Methods and Results:We analyzed data from 108 consecutive patients with persistent and long-standing persistent AF who were scheduled to undergo AF ablation. TEE was performed within 24 h prior to ablation. ICE was performed for 97 patients in whom a thrombus was not detected on TEE. CCT was performed in 95 patients. Thrombus or sludge was detected on TEE in 11 patients (10.3%), for whom ablation was cancelled. Four additional patients were diagnosed with LAA thrombus on ICE. When TEE and ICE were used as the reference for thrombus detection, the sensitivity, specificity, positive predictive value, and negative predictive value of CCT for identifying contrast defects in the LAA were 100%, 81.0%, 40.7%, and 100%, respectively. ICE combined with TEE increased the detection rate of LAA thrombi in patients with persistent and long-standing persistent AF. Moreover, CCT had high sensitivity and negative predictive value for LAA thrombus detection.

  20. High Speed Prototype Car Test

    NASA Image and Video Library

    2014-01-10

    CAPE CANAVERAL, Fla. - A Hennessey Venom GT stands on the 3.5-mile long runway between test runs at the Shuttle Landing Facility at NASA's Kennedy Space Center in Florida. The flat concrete runway is one of the few places in the world where high performance automobiles can be tested for aerodynamic and safety designs. Hennessey Performance of Sealy, Texas, worked with Performance Power Racing in West Palm Beach to arrange use of the NASA facility. Performance Power Racing has conducted numerous engineering tests on the runway with a variety of vehicles. Photo credit: NASA/Kim Shiflett

  1. Solid Propellant Test Article (SPTA) Test Stand

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  2. Morbidity in patients with or at high risk for obstructive sleep apnea after ambulatory laparoscopic gastric banding.

    PubMed

    Kurrek, Matt M; Cobourn, Chris; Wojtasik, Ziggy; Kiss, Alexander; Dain, Steven L

    2011-10-01

    Considerable controversy exists about the perioperative management of patients at high risk for obstructive sleep apnea (OSA) in free-standing clinics. Eighty-eight percent of an American Society of Anesthesiologists expert panel felt that upper abdominal laparoscopic surgery could not be performed safely on an outpatient basis. We sought to review the incidence of major adverse events after outpatient laparoscopic adjustable gastric banding (LAGB) in a high risk population for OSA at a free-standing facility. Research Ethics Board approval was obtained and charts were reviewed retrospectively for 2,370 LAGB performed at a free-standing clinic between 2005 and 2009. In this observational cohort study, patients were classified as high risk for OSA if they received continuous positive airway pressure (CPAP) treatment for OSA pre-operatively or had a history of at least three STOP-BANG criteria. Follow-up was verified and adverse events reviewed, including death, unanticipated transfer or admission to hospital within 30 days. A total of 746 of the 2,370 patients (31%) met criteria for or were at high risk for OSA (357 received CPAP for OSA and 389 by STOP-BANG criteria). The incidence of transient desaturation to less than 93% was 39.5%. There were no deaths and no cases of respiratory failure or re-intubation. The 30-day mortality was zero and the 30-day anesthesia related morbidity was less than 0.5%. For patients at high risk for OSA after LAGB, the significance of transient oxygen desaturation and the need to develop monitoring and admission standards remain to be determined.

  3. Performance scores and standings during the 43rd Artistic Gymnastics World Championships, 2011.

    PubMed

    Massidda, Myosotis; Calò, Carla M

    2012-01-01

    Scores in artistic gymnastics are subject to changes in the rules that occur each Olympic cycle as outlined in the Code of Points, because rules influence the composition of routines and therefore performance. The aim of this study was to identify the most important routine apparatus for success in a World competition. The data were the official results for the 478 gymnasts (262 men, 216 women) who competed in the 43rd Artistic Gymnastic World Championships in 2011 in Tokyo, Japan. The factors least influenced by the technical standard of competitors were performance scores on uneven bars and balance beam for women, and those on pommel horse for men. For uneven bars, balance beam, and pommel horse, scores were consistently good predictors of final standing. Our results suggest that high scores on these apparatus have a greater influence on overall performance than scores on the other apparatus, regardless of the competitors' standard.

  4. Association of unipedal standing time and bone mineral density in community-dwelling Japanese women.

    PubMed

    Sakai, A; Toba, N; Takeda, M; Suzuki, M; Abe, Y; Aoyagi, K; Nakamura, T

    2009-05-01

    Bone mineral density (BMD) and physical performance of the lower extremities decrease with age. In community-dwelling Japanese women, unipedal standing time, timed up and go test, and age are associated with BMD while in women aged 70 years and over, unipedal standing time is associated with BMD. The aim of this study was to clarify whether unipedal standing time is significantly associated with BMD in community-dwelling women. The subjects were 90 community-dwelling Japanese women aged 54.7 years. BMD of the second metacarpal bone was measured by computed X-ray densitometry. We measured unipedal standing time as well as timed up and go test to assess physical performance of the lower extremities. Unipedal standing time decreased with increased age. Timed up and go test significantly correlated with age. Low BMD was significantly associated with old age, short unipedal standing time, and long timed up and go test. Stepwise regression analysis revealed that age, unipedal standing time, and timed up and go test were significant factors associated with BMD. In 21 participants aged 70 years and over, body weight and unipedal standing time, but not age, were significantly associated with BMD. BMD and physical performance of the lower extremities decrease with older age. Unipedal standing time, timed up and go test, and age are associated with BMD in community-dwelling Japanese women. In women aged 70 years and over, unipedal standing time is significantly associated with BMD.

  5. Standing Vs Supine; Does it Matter in Cough Stress Testing?

    PubMed

    Patnam, Radhika; Edenfield, Autumn L; Swift, Steven E

    The aim of this study was to compare the sensitivity of cough stress test in the standing versus supine position in the evaluation of incontinent females. We performed a prospective observational study of women with the chief complaint of urinary incontinence (UI) undergoing a provocative cough stress test (CST). Subjects underwent both a standing and a supine CST. Testing order was randomized via block randomization. Cough stress test was performed in a standard method via backfill of 200 mL or until the subject described strong urge. The subjects were asked to cough, and the physician documented urine leakage by direct observation. The gold standard for stress UI diagnosis was a positive CST in either position. Sixty subjects were enrolled, 38 (63%) tested positive on any CST, with 38 (63%) positive on standing compared with 29 (28%) positive on supine testing. Nine women (15%) had positive standing and negative supine testing. No subjects had negative standing with positive supine testing. There were no significant differences in positive tests between the 2 randomized groups (standing first and supine second vs. supine first and standing second). When compared with the gold standard of any positive provocative stress test, the supine CST has a sensitivity of 76%, whereas the standing CST has a sensitivity of 100%. The standing CST is more sensitive than the supine CST and should be performed in any patient with a complaint of UI and negative supine CST. The order of testing either supine or standing first does not affect the results.

  6. Postural strategy and trunk muscle activation during prolonged standing in chronic low back pain patients.

    PubMed

    Ringheim, Inge; Austein, Helene; Indahl, Aage; Roeleveld, Karin

    2015-10-01

    Prolonged standing has been associated with development and aggravation of low back pain (LBP). However, the underlying mechanisms are not well known. The aim of the present study was to investigate postural control and muscle activation during and as a result of prolonged standing in chronic LBP (cLBP) patients compared to healthy controls (HCs). Body weight shifts and trunk and hip muscle activity was measured during 15 min standing. Prior and after the standing trial, strength, postural sway, reposition error (RE), flexion relaxation ratio (FRR), and pain were assessed and after the prolonged standing, ratings of perceived exertion. During prolonged standing, the cLBP patients performed significantly more body weight shifts (p<.01) with more activated back and abdominal muscles (p=.01) and similar temporal variability in muscle activation compared to HCs, while the cLBP patients reported more pain and perceived exertion at the end of prolonged standing. Moreover, both groups had a similar change in strength, postural sway, RE and FRR from before to after prolonged standing, where changes in HC were towards pre-standing values of cLBP patients. Thus, despite a more variable postural strategy, the cLBP patients did not have higher muscle activation variability, but a general increased muscle activation level. This may indicate a reduced ability to individually deactivate trunk muscles. Plausibly, due to the increased variable postural strategy, the cLBP patients could compensate for the relatively high muscle activation level, resulting in normal variation in muscle activation and normal reduction in strength, RE and FRR after prolonged standing. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Standing-up exerciser based on functional electrical stimulation and body weight relief.

    PubMed

    Ferrarin, M; Pavan, E E; Spadone, R; Cardini, R; Frigo, C

    2002-05-01

    The goal of the present work was to develop and test an innovative system for the training of paraplegic patients when they are standing up. The system consisted of a computer-controlled stimulator, surface electrodes for quadricep muscle stimulation, two knee angle sensors, a digital proportional-integrative-derivative (PID) controller and a mechanical device to support, partially, the body weight (weight reliever (WR)). A biomechanical model of the combined WR and patient was developed to find an optimum reference trajectory for the PID controller. The system was tested on three paraplegic patients and was shown to be reliable and safe. One patient completed a 30-session training period. Initially he was able to stand up only with 62% body weight relief, whereas, after the training period, he performed a series of 30 standing-up/sitting-down cycles with 45% body weight relief. The closed-loop controller was able to keep the patient standing upright with minimum stimulation current, to compensate automatically for muscle fatigue and to smooth the sitting-down movement. The limitations of the controller in connection with a highly non-linear system are considered.

  8. Increasing passive energy expenditure during clerical work.

    PubMed

    Beers, Erik A; Roemmich, James N; Epstein, Leonard H; Horvath, Peter J

    2008-06-01

    Sitting on a therapy ball or standing may be a passive means of increasing energy expenditure throughout the workday. The purpose of this study was to determine the energy expenditure and liking of performing clerical work in various postures. Subjects included 24 men and women employed in sedentary clerical occupations. Energy expenditure was measured while word processing in three standardized postures; sitting in an office chair, sitting on a therapy ball, and standing. Adults ranked their comfort, fatigue, and liking of each posture and were asked to perform their choice of 20 min of additional clerical work in one of the postures. Energy expenditure was 4.1 kcal/h greater (p or= 0.48). Subjects also liked sitting on a therapy ball as much as sitting in an office chair and liked sitting on a therapy ball more than standing (p

  9. 49 CFR 40.21 - May an employer stand down an employee before the MRO has completed the verification process?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... which DOT agencies regulate your employees. (2) Your proposed written company policy concerning stand... temporary removal from performance of safety-sensitive functions becomes available, directly or indirectly... a covered employee will be subject to stand-down only with respect to the actual performance of...

  10. Enabling People with Developmental Disabilities to Actively Follow Simple Instructions and Perform Designated Physical Activities According to Simple Instructions with Nintendo Wii Balance Boards by Controlling Environmental Stimulation

    ERIC Educational Resources Information Center

    Shih, Ching-Hsiang; Chung, Chiao-Chen; Shih, Ching-Tien; Chen, Ling-Che

    2011-01-01

    The latest researches have adopted software technology turning the Nintendo Wii Balance Board into a high performance standing location detector. This study extended Wii Balance Board functionality to assess whether two people with developmental disabilities would be able to actively perform designated physical activities according to simple…

  11. [Sequential sampling plans to Orthezia praelonga Douglas (Hemiptera: Sternorrhyncha, Ortheziidae) in citrus].

    PubMed

    Costa, Marilia G; Barbosa, José C; Yamamoto, Pedro T

    2007-01-01

    The sequential sampling is characterized by using samples of variable sizes, and has the advantage of reducing sampling time and costs if compared to fixed-size sampling. To introduce an adequate management for orthezia, sequential sampling plans were developed for orchards under low and high infestation. Data were collected in Matão, SP, in commercial stands of the orange variety 'Pêra Rio', at five, nine and 15 years of age. Twenty samplings were performed in the whole area of each stand by observing the presence or absence of scales on plants, being plots comprised of ten plants. After observing that in all of the three stands the scale population was distributed according to the contagious model, fitting the Negative Binomial Distribution in most samplings, two sequential sampling plans were constructed according to the Sequential Likelihood Ratio Test (SLRT). To construct these plans an economic threshold of 2% was adopted and the type I and II error probabilities were fixed in alpha = beta = 0.10. Results showed that the maximum numbers of samples expected to determine control need were 172 and 76 samples for stands with low and high infestation, respectively.

  12. Formation of definite GaN p-n junction by Mg-ion implantation to n--GaN epitaxial layers grown on a high-quality free-standing GaN substrate

    NASA Astrophysics Data System (ADS)

    Oikawa, Takuya; Saijo, Yusuke; Kato, Shigeki; Mishima, Tomoyoshi; Nakamura, Tohru

    2015-12-01

    P-type conversion of n--GaN by Mg-ion implantation was successfully performed using high quality GaN epitaxial layers grown on free-standing low-dislocation-density GaN substrates. These samples showed low-temperature PL spectra quite similar to those observed from Mg-doped MOVPE-grown p-type GaN, consisting of Mg related donor-acceptor pair (DAP) and acceptor bound exciton (ABE) emission. P-n diodes fabricated by the Mg-ion implantation showed clear rectifying I-V characteristics and UV and blue light emissions were observed at forward biased conditions for the first time.

  13. High-power arrays of quantum cascade laser master-oscillator power-amplifiers.

    PubMed

    Rauter, Patrick; Menzel, Stefan; Goyal, Anish K; Wang, Christine A; Sanchez, Antonio; Turner, George; Capasso, Federico

    2013-02-25

    We report on multi-wavelength arrays of master-oscillator power-amplifier quantum cascade lasers operating at wavelengths between 9.2 and 9.8 μm. All elements of the high-performance array feature longitudinal (spectral) as well as transverse single-mode emission at peak powers between 2.7 and 10 W at room temperature. The performance of two arrays that are based on different seed-section designs is thoroughly studied and compared. High output power and excellent beam quality render the arrays highly suitable for stand-off spectroscopy applications.

  14. A three-dimensional self-assembled SnS 2 -nano-dots@graphene hybrid aerogel as an efficient polysulfide reservoir for high-performance lithium–sulfur batteries

    DOE PAGES

    Luo, Liu; Chung, Sheng-Heng; Manthiram, Arumugam

    2018-01-01

    A free-standing self-assembled graphene aerogel embedded with SnS 2 nano-dots (SnS 2 -ND@G) is established as an efficient substrate for high-loading sulfur cathodes with synergistically physical and chemical polysulfide-trapping capability.

  15. A three-dimensional self-assembled SnS 2 -nano-dots@graphene hybrid aerogel as an efficient polysulfide reservoir for high-performance lithium–sulfur batteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Liu; Chung, Sheng-Heng; Manthiram, Arumugam

    A free-standing self-assembled graphene aerogel embedded with SnS 2 nano-dots (SnS 2 -ND@G) is established as an efficient substrate for high-loading sulfur cathodes with synergistically physical and chemical polysulfide-trapping capability.

  16. Nanoporous distributed Bragg reflectors on free-standing nonpolar m-plane GaN

    NASA Astrophysics Data System (ADS)

    Mishkat-Ul-Masabih, Saadat; Luk, Ting Shan; Rishinaramangalam, Ashwin; Monavarian, Morteza; Nami, Mohsen; Feezell, Daniel

    2018-01-01

    We report the fabrication of m-plane nanoporous distributed Bragg reflectors (DBRs) on free-standing GaN substrates. The DBRs consist of 15 pairs of alternating undoped and highly doped n-type ([Si] = ˜3.7 × 1019 cm-3) GaN. Electrochemical (EC) etching was performed to convert the highly doped regions into a porous material, consequently reducing the effective refractive index of the layers. We demonstrate a DBR with peak reflectance greater than 98% at 450 nm with a stopband width of ˜72 nm. The polarization ratio of an incident polarized light source remains identical after reflection from the DBR, verifying that there is no drop in the polarization ratio due to the interfaces between the porous layers. We also quantify the porosity under various EC bias conditions for layers with different doping concentrations. The bias voltage controls the average pore diameter, while the pore density is primarily determined by the doping concentration. The results show that nanoporous DBRs on nonpolar free-standing GaN are promising candidates for high-reflectance, lattice-matched DBR mirrors for GaN-based resonant cavity devices.

  17. A wireless object location detector enabling people with developmental disabilities to control environmental stimulation through simple occupational activities with Nintendo Wii Balance Boards.

    PubMed

    Shih, Ching-Hsiang; Chang, Man-Ling

    2012-01-01

    The latest researches have adopted software technology, turning the Nintendo Wii Balance Board into a high performance standing location detector with a newly developed standing location detection program (SLDP). This study extended SLDP functionality to assess whether two people with developmental disabilities would be able to actively perform simple occupational activities by controlling their favorite environmental stimulation using Nintendo Wii Balance Boards and SLDP software. An ABAB design was adopted in this study to perform the tests. The test results showed that, during the intervention phases, both participants significantly increased their target response (i.e. simple occupational activity) to activate the control system to produce environmental stimulation. The practical and developmental implications of the findings are discussed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Robot-operated quality control station based on the UTT method

    NASA Astrophysics Data System (ADS)

    Burghardt, Andrzej; Kurc, Krzysztof; Szybicki, Dariusz; Muszyńska, Magdalena; Nawrocki, Jacek

    2017-03-01

    This paper presents a robotic test stand for the ultrasonic transmission tomography (UTT) inspection of stator vane thickness. The article presents the method of the test stand design in Autodesk Robot Structural Analysis Professional 2013 software suite. The performance of the designed test stand solution was simulated in the RobotStudio software suite. The operating principle of the test stand measurement system is presented with a specific focus on the measurement strategy. The results of actual wall thickness measurements performed on stator vanes are presented.

  19. A novel application of PageRank and user preference algorithms for assessing the relative performance of track athletes in competition

    PubMed Central

    Shepherd, Simon J.; Emmonds, Stacey; Jones, Ben

    2017-01-01

    Ranking enables coaches, sporting authorities, and pundits to determine the relative performance of individual athletes and teams in comparison to their peers. While ranking is relatively straightforward in sports that employ traditional leagues, it is more difficult in sports where competition is fragmented (e.g. athletics, boxing, etc.), with not all competitors competing against each other. In such situations, complex points systems are often employed to rank athletes. However, these systems have the inherent weakness that they frequently rely on subjective assessments in order to gauge the calibre of the competitors involved. Here we show how two Internet derived algorithms, the PageRank (PR) and user preference (UP) algorithms, when utilised with a simple ‘who beat who’ matrix, can be used to accurately rank track athletes, avoiding the need for subjective assessment. We applied the PR and UP algorithms to the 2015 IAAF Diamond League men’s 100m competition and compared their performance with the Keener, Colley and Massey ranking algorithms. The top five places computed by the PR and UP algorithms, and the Diamond League ‘2016’ points system were all identical, with the Kendall’s tau distance between the PR standings and ‘2016’ points system standings being just 15, indicating that only 5.9% of pairs differed in their order between these two lists. By comparison, the UP and ‘2016’ standings displayed a less strong relationship, with a tau distance of 95, indicating that 37.6% of the pairs differed in their order. When compared with the standings produced using the Keener, Colley and Massey algorithms, the PR standings appeared to be closest to the Keener standings (tau distance = 67, 26.5% pair order disagreement), whereas the UP standings were more similar to the Colley and Massey standings, with the tau distances between these ranking lists being only 48 (19.0% pair order disagreement) and 59 (23.3% pair order disagreement) respectively. In particular, the UP algorithm ranked ‘one-off’ victors more highly than the PR algorithm, suggesting that the UP algorithm captures alternative characteristics to the PR algorithm, which may more suitable for predicting future performance in say knockout tournaments, rather than for use in competitions such as the Diamond League. As such, these Internet derived algorithms appear to have considerable potential for objectively assessing the relative performance of track athletes, without the need for complicated points equivalence tables. Importantly, because both algorithms utilise a ‘who beat who’ model, they automatically adjust for the strength of the competition, thus avoiding the need for subjective decision making. PMID:28575009

  20. Effects of pelvic compression belts on the kinematics and kinetics of the lower extremities during sit-to-stand maneuvers

    PubMed Central

    Kim, Jong Moon; Je, Hyun Dong; Kim, Hyeong-Dong

    2017-01-01

    [Purpose] To investigate the effects of a pelvic compression belt (PCB) and chair height on the kinematics and kinetics of the lower extremity during sit-to-stand (STS) maneuvers in healthy people. [Subjects and Methods] Twenty-two people participated in this study. They were required to perform STS maneuvers under four conditions. Hip joint moment and angular displacement of the hip, knee, and ankle were measured. A PCB was also applied below the anterior superior iliac spine. [Results] The angular displacement of the ankle joint increased while performing STS maneuvers from a normal chair with a PCB in phase 1, and decreased during phase 2 when performing STS maneuvers from a high chair. The overall angular displacement in phase 3 was decreased while rising from a chair with a PCB and rising from a high chair. When performed STS maneuvers from a high chair, the angular displacement of the hip, knee, and ankle joint decreased considerably in phase 3. This decreased lower extremity motion in phase 3 indicated that participants required less momentum to complete the maneuver. [Conclusion] The results of this study suggest that a PCB might be appropriate for patients with pelvic girdle pain and lower back pain related to pregnancy. PMID:28878454

  1. Effects of pelvic compression belts on the kinematics and kinetics of the lower extremities during sit-to-stand maneuvers.

    PubMed

    Kim, Jong Moon; Je, Hyun Dong; Kim, Hyeong-Dong

    2017-08-01

    [Purpose] To investigate the effects of a pelvic compression belt (PCB) and chair height on the kinematics and kinetics of the lower extremity during sit-to-stand (STS) maneuvers in healthy people. [Subjects and Methods] Twenty-two people participated in this study. They were required to perform STS maneuvers under four conditions. Hip joint moment and angular displacement of the hip, knee, and ankle were measured. A PCB was also applied below the anterior superior iliac spine. [Results] The angular displacement of the ankle joint increased while performing STS maneuvers from a normal chair with a PCB in phase 1, and decreased during phase 2 when performing STS maneuvers from a high chair. The overall angular displacement in phase 3 was decreased while rising from a chair with a PCB and rising from a high chair. When performed STS maneuvers from a high chair, the angular displacement of the hip, knee, and ankle joint decreased considerably in phase 3. This decreased lower extremity motion in phase 3 indicated that participants required less momentum to complete the maneuver. [Conclusion] The results of this study suggest that a PCB might be appropriate for patients with pelvic girdle pain and lower back pain related to pregnancy.

  2. B-1 and B-3 Test Stands at NASA’s Plum Brook Station

    NASA Image and Video Library

    1966-09-21

    Operation of the High Energy Rocket Engine Research Facility (B-1), left, and Nuclear Rocket Dynamics and Control Facility (B-3) at the National Aeronautics and Space Administration’s (NASA) Plum Brook Station in Sandusky, Ohio. The test stands were constructed in the early 1960s to test full-scale liquid hydrogen fuel systems in simulated altitude conditions. Over the next decade each stand was used for two major series of liquid hydrogen rocket tests: the Nuclear Engine for Rocket Vehicle Application (NERVA) and the Centaur second-stage rocket program. The different components of these rocket engines could be studied under flight conditions and adjusted without having to fire the engine. Once the preliminary studies were complete, the entire engine could be fired in larger facilities. The test stands were vertical towers with cryogenic fuel and steam ejector systems. B-1 was 135 feet tall, and B-3 was 210 feet tall. Each test stand had several levels, a test section, and ground floor shop areas. The test stands relied on an array of support buildings to conduct their tests, including a control building, steam exhaust system, and fuel storage and pumping facilities. A large steam-powered altitude exhaust system reduced the pressure at the exhaust nozzle exit of each test stand. This allowed B-1 and B-3 to test turbopump performance in conditions that matched the altitudes of space.

  3. Free-standing and flexible organic cathode based on aromatic carbonyl compound/carbon nanotube composite for lithium and sodium organic batteries.

    PubMed

    Yuan, Chenpei; Wu, Qiong; Shao, Qi; Li, Qiang; Gao, Bo; Duan, Qian; Wang, Heng-Guo

    2018-05-01

    Free-standing and flexible organic cathode based on aromatic carbonyl compound/carbon nanotubes (CNTs) has been successfully synthesized by a simple vacuum filtration strategy. The obtained flexible and free-standing film could be directly used as the binder-, additive- and current collector-free cathode for lithium ion batteries (LIBs) and sodium ion batteries (SIBs). Benefitting from the synergistic effect provided by the aromatic carbonyl compound and CNTs, the flexible organic cathode shows excellent lithium and sodium storage properties, including high reversible capacity (∼150 mAh g -1 at 50 mA g -1 for LIBs and 57.8 mAh g -1 at 25 mA g -1 for SIBs), excellent cycling stability (over 500 cycles for LIBs and 300 cycles for SIBs) and good rate capability (48 mAh g -1 even at 2000 mA g -1 for LIBs and 48 mAh g -1 even at 1000 mA g -1 for SIBs). In view of the simple preparation process and excellent performance, the proposed strategy might open new avenues for the design of high-performance flexible organic electrode for the application in energy storage and conversion. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. The correlations of the electronic structure and film growth of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on SiO2.

    PubMed

    Lyu, Lu; Niu, Dongmei; Xie, Haipeng; Zhao, Yuan; Cao, Ningtong; Zhang, Hong; Zhang, Yuhe; Liu, Peng; Gao, Yongli

    2017-01-04

    Combining ultraviolet photoemission spectroscopy (UPS), X-ray photoemission spectroscopy (XPS), atomic force microscopy (AFM) and small angle X-ray diffraction (SAXD) measurements, we perform a systematic investigation on the correlations of the electronic structure, film growth and molecular orientation of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on silicon oxide (SiO 2 ). AFM analysis reveals a phase transition of disorderedly oriented molecules in clusters in thinner films to highly ordered standing-up molecules in islands in thicker films. SAXD peaks consistently support the standing-up configuration in islands. The increasing ordering of the molecular orientation with film thickness contributes to the changing of the shape and lowering of the leading edge of the highest occupied molecular orbital (HOMO). The end methyl of the highly ordered standing molecules forms an outward pointing dipole layer which makes the work function (WF) decrease with increasing thickness. The downward shift of the HOMO and a decrease of WF result in unconventional downward band bending and decreased ionization potential (IP). The correlations of the orientation ordering of molecules, film growth and interface electronic structures provide a useful design strategy to improve the performance of C8-BTBT thin film based field effect transistors.

  5. Stand structure modulates the long-term vulnerability of Pinus halepensis to climatic drought in a semiarid Mediterranean ecosystem.

    PubMed

    Moreno-Gutiérrez, Cristina; Battipaglia, Giovanna; Cherubini, Paolo; Saurer, Matthias; Nicolás, Emilio; Contreras, Sergio; Querejeta, José Ignacio

    2012-06-01

    We investigated whether stand structure modulates the long-term physiological performance and growth of Pinus halepensis Mill. in a semiarid Mediterranean ecosystem. Tree radial growth and carbon and oxygen stable isotope composition of latewood (δ(13)C(LW) and δ(18)O(LW), respectively) from 1967 to 2007 were measured in P. halepensis trees from two sharply contrasting stand types: open woodlands with widely scattered trees versus dense afforested stands. In both stand types, tree radial growth, δ(13)C(LW) and δ(18)O(LW) were strongly correlated with annual rainfall, thus indicating that tree performance in this semiarid environment is largely determined by inter-annual changes in water availability. However, trees in dense afforested stands showed consistently higher δ(18)O(LW) and similar δ(13)C(LW) values compared with those in neighbouring open woodlands, indicating lower stomatal conductance and photosynthesis rates in the former, but little difference in water use efficiency between stand types. Trees in dense afforested stands were more water stressed and showed lower radial growth, overall suggesting greater vulnerability to drought and climate aridification compared with trees in open woodlands. In this semiarid ecosystem, the negative impacts of intense inter-tree competition for water on P. halepensis performance clearly outweigh potential benefits derived from enhanced infiltration and reduced run-off losses in dense afforested stands. © 2011 Blackwell Publishing Ltd.

  6. Comparison of Test Stand and Helicopter Oil Cooler Bearing Condition Indicators

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Branning, Jeremy; Wade, Damiel R.; Bolander, Nathan

    2010-01-01

    The focus of this paper was to compare the performance of HUMS condition indicators (CI) when detecting a bearing fault in a test stand or on a helicopter. This study compared data from two sources: first, CI data collected from accelerometers installed on two UH-60 Black Hawk helicopters when oil cooler bearing faults occurred, along with data from helicopters with no bearing faults; and second, CI data that was collected from ten cooler bearings, healthy and faulted, that were removed from fielded helicopters and installed in a test stand. A method using Receiver Operating Characteristic (ROC) curves to compare CI performance was demonstrated. Results indicated the bearing energy CI responded differently for the helicopter and the test stand. Future research is required if test stand data is to be used validate condition indicator performance on a helicopter.

  7. A comparative study of the five-times-sit-to-stand and timed-up-and-go tests as measures of functional mobility in persons with and without injection-related venous ulcers.

    PubMed

    Pieper, Barbara; Templin, Thomas N; Goldberg, Allon

    2014-02-01

    To provide information on the Five-Times-Sit-to-Stand (FTSTS) and Timed-Up-and-Go (TUG) tests in persons with injection-related venous ulcers (VU+) and persons without venous ulcers (VU-). This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to: To examine functional mobility using Five-Times-Sit-to-Stand (FTSTS) and Timed-Up-and-Go (TUG) tests in persons with injection-related venous ulcers (VU+) and compare these findings to persons without venous ulcers (VU-). Cross-sectional, comparative design. Outpatient clinic.PARTICPANTS: Participants (n = 61) were 31 persons VU+ and 30 persons VU-; 57.4% men; mean age, 54 years; 93% African American. Five-Times-Sit-to-Stand, TUG, physical activity, quality of life, comorbidities, falls, and body mass index. Participants VU+ were 36.8% slower on completion of the TUG test (P = .012) and 26.5% slower on completion of the FTSTS test (P = .081). Five-Times-Sit-to-Stand and TUG were strongly correlated with each other, r = 0.93, 0.87, P < .001 for VU- and VU+, respectively. Test-retest reliabilities for the FTSTS and TUG tests were high (intraclass correlation coefficient = 0.89-0.94) for the VU+ and VU-. Within each group, correlations of FTSTS and TUG were similar for each of the variables examined. Across groups, correlations showed that the time to complete FTSTS and TUG increased as a function of comorbidities in the VU+ group; the correlations in the VU- group were not significantly different from zero. The VU+ group exhibited poorer physical performance than the VU- group. The high correlation between FTSTS and TUG and the similarity of correlations with other variables suggest that these physical performance measures may be interchangeable in their ability to predict physical functioning in these clinical groups despite differences in test demands. Clinicians need easy-to-perform reliable clinical tests such as FTSTS and TUG to assess mobility of aging injection users with venous ulcers.

  8. Validity of linear encoder measurement of sit-to-stand performance power in older people.

    PubMed

    Lindemann, U; Farahmand, P; Klenk, J; Blatzonis, K; Becker, C

    2015-09-01

    To investigate construct validity of linear encoder measurement of sit-to-stand performance power in older people by showing associations with relevant functional performance and physiological parameters. Cross-sectional study. Movement laboratory of a geriatric rehabilitation clinic. Eighty-eight community-dwelling, cognitively unimpaired older women (mean age 78 years). Sit-to-stand performance power and leg power were assessed using a linear encoder and the Nottingham Power Rig, respectively. Gait speed was measured on an instrumented walkway. Maximum quadriceps and hand grip strength were assessed using dynamometers. Mid-thigh muscle cross-sectional area of both legs was measured using magnetic resonance imaging. Associations of sit-to-stand performance power with power assessed by the Nottingham Power Rig, maximum gait speed and muscle cross-sectional area were r=0.646, r=0.536 and r=0.514, respectively. A linear regression model explained 50% of the variance in sit-to-stand performance power including muscle cross-sectional area (p=0.001), maximum gait speed (p=0.002), and power assessed by the Nottingham Power Rig (p=0.006). Construct validity of linear encoder measurement of sit-to-stand power was shown at functional level and morphological level for older women. This measure could be used in routine clinical practice as well as in large-scale studies. DRKS00003622. Copyright © 2015 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  9. Thoracoscopic diaphragmatic hernia repair in a warmblood mare.

    PubMed

    Röcken, Michael; Mosel, Gesine; Barske, Katharine; Witte, Tanja S

    2013-06-01

    To describe successful repair of a diaphragmatic hernia in a standing sedated horse using a minimally invasive thoracoscopic technique. Clinical report. Warmblood mare with a diaphragmatic hernia. An 18-year-old Warmblood mare with severe colic was referred for surgical treatment of small intestinal strangulation in a diaphragmatic defect. Twelve days after initial conventional colic surgery, left-sided laparoscopy in the standing sedated mare for diaphragmatic herniorrhaphy failed because the spleen obscured the hernia. One week later, a left-sided thoracoscopy was performed in the standing sedated horse and the hernia repaired by an intrathoracic suture technique. No long-term complications occurred (up to 4 years) and the mare returned to her previous athletic activity, followed by use as a broodmare. To avoid the high risks associated with general anesthesia, and to reduce surgical trauma and postoperative recovery, central diaphragmatic hernias are amenable to repair using a minimally invasive thoracoscopic technique in the standing sedated horse. © Copyright 2013 by The American College of Veterinary Surgeons.

  10. DMI's Baltic Sea Coastal operational forecasting system

    NASA Astrophysics Data System (ADS)

    Murawski, Jens; Berg, Per; Weismann Poulsen, Jacob

    2017-04-01

    Operational forecasting is challenged with bridging the gap between the large scales of the driving weather systems and the local, human scales of the model applications. The limit of what can be represented by local model has been continuously shifted to higher and higher spatial resolution, with the aim to better resolve the local dynamic and to make it possible to describe processes that could only be parameterised in older versions, with the ultimate goal to improve the quality of the forecast. Current hardware trends demand a str onger focus on the development of efficient, highly parallelised software and require a refactoring of the code with a solid focus on portable performance. The gained performance can be used for running high resolution model with a larger coverage. Together with the development of efficient two-way nesting routines, this has made it possible to approach the near-coastal zone with model applications that can run in a time effective way. Denmarks Meteorological Institute uses the HBM(1) ocean circulation model for applications that covers the entire Baltic Sea and North Sea with an integrated model set-up that spans the range of horizontal resolution from 1nm for the entire Baltic Sea to approx. 200m resolution in local fjords (Limfjord). For the next model generation, the high resolution set-ups are going to be extended and new high resolution domains in coastal zones are either implemented or tested for operational use. For the first time it will be possible to cover large stretches of the Baltic coastal zone with sufficiently high resolution to model the local hydrodynamic adequately. (1) HBM stands for HIROMB-BOOS-Model, whereas HIROMB stands for "High Resolution Model for the Baltic Sea" and BOOS stands for "Baltic Operational Oceanography System".

  11. Kinematic Analysis of the Standing Long Jump in Children 6- to 12-Years-Old

    ERIC Educational Resources Information Center

    Fernandez-Santos, Jorge R.; Gonzalez-Montesinos, Jose Luis; Ruiz, Jonatan R.; Jiménez-Pavón, David; Castro-Piñero, Jose

    2018-01-01

    The purpose of this study was to analyze the kinematic variables that determine the performance of the standing long jump in children 6- to 12-years-old. There were 121 healthy children (58 girls) recorded while they performed the standing long jump test. All kinematic variables showed a significant correlation with calculated jump distance and…

  12. Collective hormonal profiles predict group performance.

    PubMed

    Akinola, Modupe; Page-Gould, Elizabeth; Mehta, Pranjal H; Lu, Jackson G

    2016-08-30

    Prior research has shown that an individual's hormonal profile can influence the individual's social standing within a group. We introduce a different construct-a collective hormonal profile-which describes a group's hormonal make-up. We test whether a group's collective hormonal profile is related to its performance. Analysis of 370 individuals randomly assigned to work in 74 groups of three to six individuals revealed that group-level concentrations of testosterone and cortisol interact to predict a group's standing across groups. Groups with a collective hormonal profile characterized by high testosterone and low cortisol exhibited the highest performance. These collective hormonal level results remained reliable when controlling for personality traits and group-level variability in hormones. These findings support the hypothesis that groups with a biological propensity toward status pursuit (high testosterone) coupled with reduced stress-axis activity (low cortisol) engage in profit-maximizing decision-making. The current work extends the dual-hormone hypothesis to the collective level and provides a neurobiological perspective on the factors that determine who rises to the top across, not just within, social hierarchies.

  13. Collective hormonal profiles predict group performance

    PubMed Central

    Akinola, Modupe; Page-Gould, Elizabeth; Mehta, Pranjal H.; Lu, Jackson G.

    2016-01-01

    Prior research has shown that an individual’s hormonal profile can influence the individual’s social standing within a group. We introduce a different construct—a collective hormonal profile—which describes a group’s hormonal make-up. We test whether a group’s collective hormonal profile is related to its performance. Analysis of 370 individuals randomly assigned to work in 74 groups of three to six individuals revealed that group-level concentrations of testosterone and cortisol interact to predict a group’s standing across groups. Groups with a collective hormonal profile characterized by high testosterone and low cortisol exhibited the highest performance. These collective hormonal level results remained reliable when controlling for personality traits and group-level variability in hormones. These findings support the hypothesis that groups with a biological propensity toward status pursuit (high testosterone) coupled with reduced stress-axis activity (low cortisol) engage in profit-maximizing decision-making. The current work extends the dual-hormone hypothesis to the collective level and provides a neurobiological perspective on the factors that determine who rises to the top across, not just within, social hierarchies. PMID:27528679

  14. The Effects of the Mountain Pine Beetle on Snow Accumulation and Melt Timing in the Headwaters of the Colorado River

    NASA Astrophysics Data System (ADS)

    Pugh, E. T.; Small, E. E.

    2010-12-01

    The high-elevation forests that are a primary source for Colorado’s domestic and agricultural water needs are changing rapidly due to an infestation by the mountain pine beetle (MPB). MPB are native to Colorado’s high elevation forests. However, the frequency of MPB infestation and resulting tree death has increased dramatically over the past 15 years. In Colorado, over 8,000 km2 of Lodgepole (Pinus contorta) and Ponderosa Pine (Pinus ponderosa) forest have been infested by MPB since 1996. It is predicted that the current epidemic will kill most of the pines in these areas; MPB are very destructive to forest canopies, often killing all of the overhead trees within lodgepole pine stands. Current widespread MPB outbreaks are not limited to Colorado; they are also impacting forests in much of the Western US and British Columbia, Canada. This study is focused on quantifying the impacts of widespread tree death on Colorado’s mountain snowpack. The data were collected one to three years after beetle infestation, at various stages of tree mortality. During the winters of 2009 and 2010, snowpack and meteorological properties were measured at eight pairs of dead and living lodgepole pine stands. All stands are located at an elevation of 2720 ± 32m, in a subalpine region along the headwaters of the Colorado River. Trees in living stands were generally smaller in diameter and more densely populated than trees in dead stands. In the red phase of tree death, snowpack accumulated equally beneath living and dead tree stands. Additionally, snow under all tree stands became isothermal on the same date regardless of mortality. However, the snow was depleted as much as one week earlier beneath red phase dead stands. Canopy transmission of solar radiation was not consistently different between living and red phase dead stands. We noted more ground litter in red phase dead stands which would decrease snowpack albedo and lead to the snowmelt differences observed. We also performed an albedo experiment to quantify the impact of surface litter on snow albedo. Results are also reported for more advanced grey phase dead stands. Lastly, we present a conceptual model of how the primary snow processes change with time as tree mortality progresses through various stages and introduce future work.

  15. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board.

    PubMed

    Yamako, Go; Chosa, Etsuo; Totoribe, Koji; Fukao, Yuu; Deng, Gang

    2017-01-01

    Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score) and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20-88 years; male/female ratio, 226/277) without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual's mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland-Altman plot (bias = -3.1 [ms]-1, 95% limit of agreement: -11.0 to 3.9 [ms]-1). The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87). Furthermore, the test-retest reliability is substantial (intraclass correlation coefficient = 0.64). Thus, the proposed STS score will be useful to detect the early deterioration of motor performance.

  16. Quantification of the sit-to-stand movement for monitoring age-related motor deterioration using the Nintendo Wii Balance Board

    PubMed Central

    Chosa, Etsuo; Totoribe, Koji; Fukao, Yuu; Deng, Gang

    2017-01-01

    Simple methods for quantitative evaluations of individual motor performance are crucial for the early detection of motor deterioration. Sit-to-stand movement from a chair is a mechanically demanding component of activities of daily living. Here, we developed a novel method using the ground reaction force and center of pressure measured from the Nintendo Wii Balance Board to quantify sit-to-stand movement (sit-to-stand score) and investigated the age-related change in the sit-to-stand score as a method to evaluate reduction in motor performance. The study enrolled 503 participants (mean age ± standard deviation, 51.0 ± 19.7 years; range, 20–88 years; male/female ratio, 226/277) without any known musculoskeletal conditions that limit sit-to-stand movement, which were divided into seven 10-year age groups. The participants were instructed to stand up as quickly as possible, and the sit-to-stand score was calculated as the combination of the speed and balance indices, which have a tradeoff relationship. We also performed the timed up and go test, a well-known clinical test used to evaluate an individual’s mobility. There were significant differences in the sit-to-stand score and timed up and go time among age groups. The mean sit-to-stand score for 60s, 70s, and 80s were 77%, 68%, and 53% of that for the 20s, respectively. The timed up and go test confirmed the age-related decrease in mobility of the participants. In addition, the sit-to-stand score measured using the Wii Balance Board was compared with that from a laboratory-graded force plate using the Bland–Altman plot (bias = −3.1 [ms]-1, 95% limit of agreement: −11.0 to 3.9 [ms]-1). The sit-to-stand score has good inter-device reliability (intraclass correlation coefficient = 0.87). Furthermore, the test–retest reliability is substantial (intraclass correlation coefficient = 0.64). Thus, the proposed STS score will be useful to detect the early deterioration of motor performance. PMID:29136031

  17. High sensitivity stand-off detection and quantification of chemical mixtures using an active coherent laser spectrometer (ACLaS)

    NASA Astrophysics Data System (ADS)

    MacLeod, Neil A.; Weidmann, Damien

    2016-05-01

    High sensitivity detection, identification and quantification of chemicals in a stand-off configuration is a highly sought after capability across the security and defense sector. Specific applications include assessing the presence of explosive related materials, poisonous or toxic chemical agents, and narcotics. Real world field deployment of an operational stand-off system is challenging due to stringent requirements: high detection sensitivity, stand-off ranges from centimeters to hundreds of meters, eye-safe invisible light, near real-time response and a wide chemical versatility encompassing both vapor and condensed phase chemicals. Additionally, field deployment requires a compact, rugged, power efficient, and cost-effective design. To address these demanding requirements, we have developed the concept of Active Coherent Laser Spectrometer (ACLaS), which can be also described as a middle infrared hyperspectral coherent lidar. Combined with robust spectral unmixing algorithms, inherited from retrievals of information from high-resolution spectral data generated by satellitebased spectrometers, ACLaS has been demonstrated to fulfil the above-mentioned needs. ACLaS prototypes have been so far developed using quantum cascade lasers (QCL) and interband cascade lasers (ICL) to exploit the fast frequency tuning capability of these solid state sources. Using distributed feedback (DFB) QCL, demonstration and performance analysis were carried out on narrow-band absorbing chemicals (N2O, H2O, H2O2, CH4, C2H2 and C2H6) at stand-off distances up to 50 m using realistic non cooperative targets such as wood, painted metal, and bricks. Using more widely tunable external cavity QCL, ACLaS has also been demonstrated on broadband absorbing chemicals (dichloroethane, HFC134a, ethylene glycol dinitrate and 4-nitroacetanilide solid) and on complex samples mixing narrow-band and broadband absorbers together in a realistic atmospheric background.

  18. Overdetermined shooting methods for computing standing water waves with spectral accuracy

    NASA Astrophysics Data System (ADS)

    Wilkening, Jon; Yu, Jia

    2012-01-01

    A high-performance shooting algorithm is developed to compute time-periodic solutions of the free-surface Euler equations with spectral accuracy in double and quadruple precision. The method is used to study resonance and its effect on standing water waves. We identify new nucleation mechanisms in which isolated large-amplitude solutions, and closed loops of such solutions, suddenly exist for depths below a critical threshold. We also study degenerate and secondary bifurcations related to Wilton's ripples in the traveling case, and explore the breakdown of self-similarity at the crests of extreme standing waves. In shallow water, we find that standing waves take the form of counter-propagating solitary waves that repeatedly collide quasi-elastically. In deep water with surface tension, we find that standing waves resemble counter-propagating depression waves. We also discuss the existence and non-uniqueness of solutions, and smooth versus erratic dependence of Fourier modes on wave amplitude and fluid depth. In the numerical method, robustness is achieved by posing the problem as an overdetermined nonlinear system and using either adjoint-based minimization techniques or a quadratically convergent trust-region method to minimize the objective function. Efficiency is achieved in the trust-region approach by parallelizing the Jacobian computation, so the setup cost of computing the Dirichlet-to-Neumann operator in the variational equation is not repeated for each column. Updates of the Jacobian are also delayed until the previous Jacobian ceases to be useful. Accuracy is maintained using spectral collocation with optional mesh refinement in space, a high-order Runge-Kutta or spectral deferred correction method in time and quadruple precision for improved navigation of delicate regions of parameter space as well as validation of double-precision results. Implementation issues for transferring much of the computation to a graphic processing units are briefly discussed, and the performance of the algorithm is tested for a number of hardware configurations.

  19. Effect of Caregiver Driven Robot-Assisted In-Ward Training in Subacute Stroke Patients: A Case Series

    PubMed Central

    2018-01-01

    Objective To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. Methods A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Results Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Conclusion Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients. PMID:29765872

  20. Effect of Caregiver Driven Robot-Assisted In-Ward Training in Subacute Stroke Patients: A Case Series.

    PubMed

    Kim, Sang Beom; Lee, Kyeong Woo; Lee, Jong Hwa; Lee, Sook Joung; Park, Jin Gee; Park, Joo Won

    2018-04-01

    To evaluate the effect of caregiver driven robot-assisted in-ward training in subacute stroke patients. A retrospective evaluation was performed for patients treated with caregiver driven robot-assisted in-ward training to retain gait function from June 2014 and December 2016. All patients received more than 2 weeks of caregiver driven robot-assisted in-ward training after undergoing conventional programs. The robot was used as a sitting device, a standing frame, or a high-walker depending on functional status of the patient. Patients were evaluated before and after robot training. Patient records were assessed by Korean version of Modified Barthel Index (K-MBI), Functional Independence Measure (FIM), and Functional Ambulation Category (FAC). Initially, patients used the robot as a sitting device (n=6), a standing frame (n=7), or a partial body-weight support high-walker (n=2). As patient functions were improved, usage level of the robot was changed to the next level. At the end of the treatment, the robot was used as a sitting device (n=1), a standing frame (n=6), or high-walker (n=8). Scores of K-MBI (Δ17.47±10.72) and FIM (Δ19.80±12.34) were improved in all patients. Patients' usage level of the robot and functional scores were improved. Therefore, performing additional caregiver driven robot-assisted in-ward training is feasible and beneficial for subacute stroke patients.

  1. A 20-liter test stand with gas purification for liquid argon research

    DOE PAGES

    Li, Y.; Thorn, C.; Tang, W.; ...

    2016-06-06

    Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  2. A 20-liter test stand with gas purification for liquid argon research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y.; Thorn, C.; Tang, W.

    Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  3. Comparisons of musculoskeletal complaints and data entry between a sitting and a sit-stand workstation paradigm.

    PubMed

    Husemann, Britta; Von Mach, Carolin Yvonne; Borsotto, Daniel; Zepf, Kirsten Isabel; Scharnbacher, Jutta

    2009-06-01

    Seated working positions are often regarded as a cause for discomfort in the musculoskeletal system. Performing work in different working positions--that is, alternating between sitting and standing (sit-stand workstation paradigm)--could help reduce physical complaints. The questions were whether performing office work partly in a standing position leads to reduced complaints and whether standing would change the efficiency of data entry office work. We investigated the effect of a sit-stand workstation paradigmd during experimental data entry office work on physical and psychological complaints and data entry efficiency by conducting a randomized controlled trial with 60 male participants ages 18 to 35 years. In this experiment, musculoskeletal complaints were reduced by a sit-stand workstation paradigm. A trend could be identified indicating a small but nonsignificant loss of efficiency in data entry while standing. A sit-stand workstation paradigm reduces musculoskeletal complaints without considerably affecting data entry efficiency under the presented study conditions (young male participants, short duration, fixed and controlled sit-stand workstation paradigm, simulated experimental working condition). According to the present data, implementing a sit-stand workstation paradigm can be an effective workplace health intervention to reduce musculoskeletal complaints. This experiment encourages further studies on the effectiveness of a sit-stand workstation paradigm. Experimental research and field studies that prove the reduction of complaints when introducing a sit-stand workstation paradigm in the workplace could be the basis for evidence-based recommendations regarding such interventions.

  4. Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1987-01-01

    A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.

  5. Suicide bomber detection

    NASA Astrophysics Data System (ADS)

    Alexander, Naomi; Callejero, Carlos; Fiore, Franco; Gómez, Ignacio; Gonzalo, Ramón; Enríquez de Luna, Álvaro; Ederra, Iñigo; Palacios, Inés

    2009-05-01

    The chance of suicide bomber attacks against troops in the Theatre of Operations is currently quite high. Most of the time checkpoints and compound gates are not equipped with the appropriate equipment to screen for potential suicide bombers. The ultimate solution would be to be able to perform stand-off screening under various weather conditions whilst avoiding contact between Force Protection personnel and potential suicide bombers. Radiation in the millimeterwave and the lower Terahertz range, having the useful property of being able to penetrate clothing in addition to fog and rain, makes it a clear candidate for imaging in this situation. A study has been made simulating real case scenarios to test practical detection performance and stand-off distances at a range of frequencies in this band, the results of which will be presented.

  6. Test stand performance of a convertible engine for advanced V/STOL and rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1988-01-01

    A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.

  7. Particulate matter concentrations in residences: an intervention study evaluating stand-alone filters and air conditioners

    PubMed Central

    Batterman, S.; Du, L.; Mentz, G.; Mukherjee, B.; Parker, E.; Godwin, C.; Chin, J.-Y.; O'Toole, A.; Robins, T.; Rowe, Z.; Lewis, T.

    2014-01-01

    This study, a randomized controlled trial, evaluated the effectiveness of free-standing air filters and window air conditioners (ACs) in 126 low-income households of children with asthma. Households were randomized into a control group, a group receiving a free-standing HEPA filter placed in the child's sleeping area, and a group receiving the filter and a window-mounted AC. Indoor air quality (IAQ) was monitored for week-long periods over three to four seasons. High concentrations of particulate matter (PM) and carbon dioxide were frequently seen. When IAQ was monitored, filters reduced PM levels in the child's bedroom by an average of 50%. Filter use varied greatly among households and declined over time, for example, during weeks when pollutants were monitored, filter use was initially high, averaging 84 ± 27%, but dropped to 63 ± 33% in subsequent seasons. In months when households were not visited, use averaged only 34 ± 30%. Filter effectiveness did not vary in homes with central or room ACs. The study shows that measurements over multiple seasons are needed to characterize air quality and filter performance. The effectiveness of interventions using free-standing air filters depends on occupant behavior, and strategies to ensure filter use should be an integral part of interventions. PMID:22145709

  8. Orientation-dependent energy level alignment and film growth of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on HOPG

    NASA Astrophysics Data System (ADS)

    Lyu, Lu; Niu, Dongmei; Xie, Haipeng; Cao, Ningtong; Zhang, Hong; Zhang, Yuhe; Liu, Peng; Gao, Yongli

    2016-01-01

    Combining ultraviolet photoemission spectroscopy, X-ray photoemission spectroscopy, atomic force microscopy, and X-ray diffraction measurements, we performed a systematic investigation on the correlation of energy level alignment, film growth, and molecular orientation of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on highly oriented pyrolytic graphite. The molecules lie down in the first layer and then stand up from the second layer. The ionization potential shows a sharp decrease from the lying down region to the standing up region. When C8-BTBT molecules start standing up, unconventional energy level band-bending-like shifts are observed as the film thickness increases. These shifts are ascribed to gradual decreasing of the molecular tilt angle about the substrate normal with the increasing film thickness.

  9. Orientation-dependent energy level alignment and film growth of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on HOPG.

    PubMed

    Lyu, Lu; Niu, Dongmei; Xie, Haipeng; Cao, Ningtong; Zhang, Hong; Zhang, Yuhe; Liu, Peng; Gao, Yongli

    2016-01-21

    Combining ultraviolet photoemission spectroscopy, X-ray photoemission spectroscopy, atomic force microscopy, and X-ray diffraction measurements, we performed a systematic investigation on the correlation of energy level alignment, film growth, and molecular orientation of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on highly oriented pyrolytic graphite. The molecules lie down in the first layer and then stand up from the second layer. The ionization potential shows a sharp decrease from the lying down region to the standing up region. When C8-BTBT molecules start standing up, unconventional energy level band-bending-like shifts are observed as the film thickness increases. These shifts are ascribed to gradual decreasing of the molecular tilt angle about the substrate normal with the increasing film thickness.

  10. Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions

    NASA Astrophysics Data System (ADS)

    Giffin, Paxton K.; Parsons, Michael S.; Unz, Ronald J.; Waggoner, Charles A.

    2012-05-01

    The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m3/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.

  11. An Interactive Simulation System for Modeling Stands, Harvests, and Machines

    Treesearch

    Jingxin Wang; W. Dale Greene

    1999-01-01

    A interactive computer simulation program models stands, harvest, and machine factors and evaluates their interatcitons while performing felling, skidding, or fowarding activities. A stand generator allows the user to generate either natural or planted stands. Fellings with chainsaw, drive-to-tree feller-bunchers, or harvesters and extraction with grapple skidders or...

  12. Time delay and integration array (TDI) using charge transfer device technology. Phase 2, volume 1: Technical

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The 20x9 TDI array was developed to meet the LANDSAT Thematic Mapper Requirements. This array is based upon a self-aligned, transparent gate, buried channel process. The process features: (1) buried channel, four phase, overlapping gate CCD's for high transfer efficiency without fat zero; (2) self-aligned transistors to minimize clock feedthrough and parasitic capacitance; and (3) transparent tin oxide electrode for high quantum efficiency with front surface irradiation. The requirements placed on the array and the performance achieved are summarized. This data is the result of flat field measurements only, no imaging or dynamic target measurements were made during this program. Measurements were performed with two different test stands. The bench test equipment fabricated for this program operated at the 8 micro sec line time and employed simple sampling of the gated MOSFET output video signal. The second stand employed Correlated Doubled Sampling (CDS) and operated at 79.2 micro sec line time.

  13. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    PubMed

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  14. 80-MHz intravascular ultrasound transducer using PMN-PT free-standing film.

    PubMed

    Li, Xiang; Wu, Wei; Chung, Youngsoo; Shih, Wan Y; Shih, Wei-Heng; Zhou, Qifa; Shung, K Kirk

    2011-11-01

    [Pb(Mg(1/3)Nb(2/3))O(3)](0.63)[PbTiO(3)](0.37) (PMN-PT) free-standing film of comparable piezoelectric properties to bulk material with thickness of 30 μm has been fabricated using a modified precursor coating approach. At 1 kHz, the dielectric permittivity and loss were 4364 and 0.033, respectively. The remnant polarization and coercive field were 28 μC/cm(2) and 18.43 kV/cm. The electromechanical coupling coefficient k(t) was measured to be 0.55, which was close to that of bulk PMN-PT single-crystal material. Based on this film, high-frequency (82 MHz) miniature ultrasonic transducers were fabricated with 65% bandwidth and 23 dB insertion loss. Axial and lateral resolutions were determined to be as high as 35 and 176 μm. In vitro intravascular imaging on healthy rabbit aorta was performed using the thin film transducers. In comparison with a 35-MHz IVUS transducer, the 80-MHz transducer showed superior resolution and contrast with satisfactory penetration depth. The imaging results suggest that PMN-PT free-standing thin film technology is a feasible and efficient way to fabricate very-high-frequency ultrasonic transducers.

  15. A Performance Analysis of a Stand-Up Paddle Board Marathon Race.

    PubMed

    Schram, Ben L; Hing, Wayne A; Climstein, Mike; Furness, James W

    2017-06-01

    Stand-up paddle boarding (SUP) is a rapidly growing sport and recreational activity in which little scientific research exists. A review of the literature failed to identify a single article pertaining to the physiological demands of SUP competition. The purpose of this study was to conduct a performance analysis of a national-level SUP marathon race. Ten elite SUP athletes (6 male and 4 female athletes) were recruited from the Stand Up Paddle Surfing Association of Australia to have their race performance in the Australian Titles analyzed. Performance variables included SUP speed, course taken, and heart rate (HR), measured with a 15-Hz global positioning system unit. Results demonstrated that there was a variation in distance covered (13.3-13.9 km), peak speed (18.8-26.4 km·h), and only moderate correlations (r = 0.38) of race result to distance covered. Significantly greater amounts of time were spent in the 5- to 10-km·h speed zones (p ≤ 0.05) during the race. Peak HR varied from 168 to 208 b·min among the competitors with the average HR being 168.6 ± 9.8 b·min. Significantly higher durations were spent in elevated HR zones (p ≤ 0.05) with participants spending 89.3% of their race within 80-100% of their age-predicted HRmax. Marathon SUP races seem to involve a high aerobic demand, with maintenance of near-maximal HRs required for the duration of the race. There is a high influence of tactical decisions and extrinsic variables to race results. These results provide a greater understanding of the physiological demands of distance events and may assist in the development of specialized training programs for SUP athletes.

  16. iPhone Sensors in Tracking Outcome Variables of the 30-Second Chair Stand Test and Stair Climb Test to Evaluate Disability: Cross-Sectional Pilot Study

    PubMed Central

    Samaan, Michael A; Schultz, Brooke; Popovic, Tijana; Souza, Richard B; Majumdar, Sharmila

    2017-01-01

    Background Performance tests are important to characterize patient disabilities and functional changes. The Osteoarthritis Research Society International and others recommend the 30-second Chair Stand Test and Stair Climb Test, among others, as core tests that capture two distinct types of disability during activities of daily living. However, these two tests are limited by current protocols of testing in clinics. There is a need for an alternative that allows remote testing of functional capabilities during these tests in the osteoarthritis patient population. Objective Objectives are to (1) develop an app for testing the functionality of an iPhone’s accelerometer and gravity sensor and (2) conduct a pilot study objectively evaluating the criterion validity and test-retest reliability of outcome variables obtained from these sensors during the 30-second Chair Stand Test and Stair Climb Test. Methods An iOS app was developed with data collection capabilities from the built-in iPhone accelerometer and gravity sensor tools and linked to Google Firebase. A total of 24 subjects performed the 30-second Chair Stand Test with an iPhone accelerometer collecting data and an external rater manually counting sit-to-stand repetitions. A total of 21 subjects performed the Stair Climb Test with an iPhone gravity sensor turned on and an external rater timing the duration of the test on a stopwatch. App data from Firebase were converted into graphical data and exported into MATLAB for data filtering. Multiple iterations of a data processing algorithm were used to increase robustness and accuracy. MATLAB-generated outcome variables were compared to the manually determined outcome variables of each test. Pearson’s correlation coefficients (PCCs), Bland-Altman plots, intraclass correlation coefficients (ICCs), standard errors of measurement, and repeatability coefficients were generated to evaluate criterion validity, agreement, and test-retest reliability of iPhone sensor data against gold-standard manual measurements. Results App accelerometer data during the 30-second Chair Stand Test (PCC=.890) and gravity sensor data during the Stair Climb Test (PCC=.865) were highly correlated to gold-standard manual measurements. Greater than 95% of values on Bland-Altman plots comparing the manual data to the app data fell within the 95% limits of agreement. Strong intraclass correlation was found for trials of the 30-second Chair Stand Test (ICC=.968) and Stair Climb Test (ICC=.902). Standard errors of measurement for both tests were found to be within acceptable thresholds for MATLAB. Repeatability coefficients for the 30-second Chair Stand Test and Stair Climb Test were 0.629 and 1.20, respectively. Conclusions App-based performance testing of the 30-second Chair Stand Test and Stair Climb Test is valid and reliable, suggesting its applicability to future, larger-scale studies in the osteoarthritis patient population. PMID:29079549

  17. Relationship-Driven Teaching Style: The Impact of Teacher-Student Relationships on Academic Performance

    ERIC Educational Resources Information Center

    Schlichte, Jacqueline; Stroud, James; Girdley, Donna

    2006-01-01

    Numbers of At-risk students are rising in the public classrooms of our day. Standardized testing is a reality that is clearly defining the great chasm that stands between the performance of these children and what is expected of their age mates. Public junior and senior high schools face the quandary: How are At-risk students to be aided in their…

  18. Inertial Sensor Based Analysis of Lie-to-Stand Transfers in Younger and Older Adults

    PubMed Central

    Schwickert, Lars; Boos, Ronald; Klenk, Jochen; Bourke, Alan; Becker, Clemens; Zijlstra, Wiebren

    2016-01-01

    Many older adults lack the capacity to stand up again after a fall. Therefore, to analyse falls it is relevant to understand recovery patterns, including successful and failed attempts to get up from the floor in general. This study analysed different kinematic features of standing up from the floor. We used inertial sensors to describe the kinematics of lie-to-stand transfer patterns of younger and healthy older adults. Fourteen younger (20–50 years of age, 50% men) and 10 healthy older community dwellers (≥60 years; 50% men) conducted four lie-to-stand transfers from different initial lying postures. The analysed temporal, kinematic, and elliptic fitting complexity measures of transfer performance were significantly different between younger and older subjects (i.e., transfer duration, angular velocity (RMS), maximum vertical acceleration, maximum vertical velocity, smoothness, fluency, ellipse width, angle between ellipses). These results show the feasibility and potential of analysing kinematic features to describe the lie-to-stand transfer performance, to help design interventions and detection approaches to prevent long lies after falls. It is possible to describe age-related differences in lie-to-stand transfer performance using inertial sensors. The kinematic analysis remains to be tested on patterns after real-world falls. PMID:27529249

  19. Effects of Post-Fire Plant Cover in the Performance of Two Cordilleran Cypress (Austrocedrus chilensis) Seedling Stocktypes Planted in Burned Forests of Northeastern Patagonia, Argentina.

    PubMed

    Urretavizcaya, María F; Gonda, Héctor E; Defossé, Guillermo E

    2017-03-01

    Cordilleran cypress (Austrocedrus chilensis [D.Don] Pic. Serm. et Bizarri) forests occupy 140,000 ha along a sharp environmental gradient of central Andean-Patagonia in Argentina. Every summer, about 3200 ha of these forests are affected by wildfires, taking thereafter long time to recover. To accelerate forest recovery, we determined in xeric and mesic cypress stands burned 5 and 2 year before whether survival and growth of two planted cypress seedling stocktypes are affected by plant cover and contrasting precipitation conditions. Two experiments were conducted on each site, involving 100 replicates of two seedling stocktypes, having each significantly different morphological attributes. The experiments comprised a dry and humid growing season on each site. Both stocktypes performed similarly within stands, but differently between stands. In the xeric stand, plant cover had neutral effects on seedling survival, favored seedling height growth in the dry season, and was negative on collar diameter and stem growth. In the mesic site, high plant cover favored survival and height growth, but was inconsequential for collar diameter and stem growth. In this short-term post-fire period, and independent of precipitation received during both seasons (dry or humid), plant cover appears as playing a facilitative role, having neutral or even positive effects on survival and growth of planted seedlings. During the early post-fire successional stages, and besides seedling stocktype, there was a synergistic balance between light and soil moisture that seems to benefit planted seedling performance in burned cypress forests, and especially in mesic sites.

  20. Effects of Post-Fire Plant Cover in the Performance of Two Cordilleran Cypress ( Austrocedrus chilensis) Seedling Stocktypes Planted in Burned Forests of Northeastern Patagonia, Argentina

    NASA Astrophysics Data System (ADS)

    Urretavizcaya, María F.; Gonda, Héctor E.; Defossé, Guillermo E.

    2017-03-01

    Cordilleran cypress ( Austrocedrus chilensis [D.Don] Pic. Serm. et Bizarri) forests occupy 140,000 ha along a sharp environmental gradient of central Andean-Patagonia in Argentina. Every summer, about 3200 ha of these forests are affected by wildfires, taking thereafter long time to recover. To accelerate forest recovery, we determined in xeric and mesic cypress stands burned 5 and 2 year before whether survival and growth of two planted cypress seedling stocktypes are affected by plant cover and contrasting precipitation conditions. Two experiments were conducted on each site, involving 100 replicates of two seedling stocktypes, having each significantly different morphological attributes. The experiments comprised a dry and humid growing season on each site. Both stocktypes performed similarly within stands, but differently between stands. In the xeric stand, plant cover had neutral effects on seedling survival, favored seedling height growth in the dry season, and was negative on collar diameter and stem growth. In the mesic site, high plant cover favored survival and height growth, but was inconsequential for collar diameter and stem growth. In this short-term post-fire period, and independent of precipitation received during both seasons (dry or humid), plant cover appears as playing a facilitative role, having neutral or even positive effects on survival and growth of planted seedlings. During the early post-fire successional stages, and besides seedling stocktype, there was a synergistic balance between light and soil moisture that seems to benefit planted seedling performance in burned cypress forests, and especially in mesic sites.

  1. The Sit & Stand chair. A revolutionary advance in adaptive seating systems.

    PubMed

    Galumbeck, Michael H; Buschbacher, Ralph M; Wilder, Robert P; Winters, Kathryne L; Hudson, Mary Anne; Edlich, Richard F

    2004-01-01

    A major factor governing independence for the elderly and persons with disabilities is the ability to stand from a chair. Factors such as pain, reduced joint range of motion, stiffness, and muscle weakness frequently limit the ability to stand. Sit-to-stand position is even further reduced in patients whose hands and shoulders are afflicted with rheumatoid arthritis. When achieving a sit-to-stand position in the elderly and persons with disabilities, there is considerable risk of the individual falling and sustaining bone fracture. The purposes of this scientific report are to achieve the following goals: (1) to provide a narrative discussion of the senior author's contributions to furniture manufacturing as well as his successful patent application for the SIT & STAND chair, (2) to describe the steps involved in the development of the SIT & STAND prototype, and (3) to examine the performance of the SIT & STAND chair in assisting the elderly or persons with disabilities in achieving a sit-to-stand position. The invention of the SIT & STAND chair by the senior author, Michael Galumbeck, was a culmination of his lifelong interest in adaptive seating systems. His electrically operated chair has the unique ability to assist the occupant to achieve safely a sit-to-stand position. The rear portion of his chair remains in a fixed position to support the buttocks of the user during mechanical lift. The front portion of the seat folds down incrementally as the chair rises to allow the feet of the user to be positioned in a more posterior position firmly on the floor. Using its actuator, the height that the chair rises will vary with the length of the legs of the occupant. Using the drawing program Solid Works (Solid Works, Concord, Massachusetts), drawings of the chair were made. To visualize the operation and performance of the chair, separate drawings were made in the lateral position. The prototype of the SIT & STAND chair was manufactured with an electric actuator that allows elevation of the back portion of the seat. The design of this chair ensured that there were no pinch points that could endanger the user or assistant. Its framework ensured that it was stable and did not tip over. After the prototype chair is manufactured, it is being sent to Underwriters Laboratory Inc. (Los Angeles, California) for review and certification. The performance of the SIT & STAND chair was determined in a clinical study involving seven elderly or disabled individuals who complained of difficulty in rising from a chair from a seated position. During each performance evaluation, a mechanical chest and shoulder harness attached to an overhead sling encircled the individual to ensure that he/she would not fall. In the first part of the evaluation, these individuals were asked to achieve a standing position after being seated in the SIT & STAND chair without the use of the actuator. Three individuals were unable to achieve a standing position, while four achieved this standing position with considerable difficulty and potential instability. When these participants used the SIT & STAND chair with the use of the electrical actuator, all individuals achieved a standing position without difficulty or instability. All individuals expressed disappointment that the SIT & STAND chair was not commercially available for them to purchase and use in their homes. Because the SIT & STAND chair allows the individual to achieve a standing position without assistance, the SIT & STAND chair has other potential benefits not evaluated in this study. The beneficial effects of standing have been documented by comprehensive scientific studies. These benefits include reduction of seating pressure, decreased bone demineralization, increased bladder pressure, enhanced circulatory regulation, reduction in muscular tone, decrease in upper extremity muscle stress, and participation in activities of daily living. Another irrefutable benefit of the SIT & STAND chair is that the chair eliminates the need for physical assistance from family members or health care personnel, preventing the development of disabling back injuries in personal care assistants. In addition, the SIT & STAND chair entirely removes the risk of pain or harm to the individual, which sometimes occurs with manual assist to stand, such as dislocation or fracture of frail shoulders with the under-axilla lift. Realizing the medical benefits of the SIT & STAND chair, Aetna completed a clinical policy bulletin that states that the seat lift mechanism is a medically necessary durable medical product. On the basis of this extensive product and performance evaluation, we recommend the SIT & STAND chair for the elderly as well as persons with disability to safely achieve a sit-to-stand position.

  2. Nanofoaming to Boost the Electrochemical Performance of Ni@Ni(OH)2 Nanowires for Ultrahigh Volumetric Supercapacitors.

    PubMed

    Xu, Shusheng; Li, Xiaolin; Yang, Zhi; Wang, Tao; Jiang, Wenkai; Yang, Chao; Wang, Shuai; Hu, Nantao; Wei, Hao; Zhang, Yafei

    2016-10-10

    Three-dimensional free-standing film electrodes have aroused great interest for energy storage devices. However, small volumetric capacity and low operating voltage limit their practical application for large energy storage applications. Herein, a facile and novel nanofoaming process was demonstrated to boost the volumetric electrochemical capacitance of the devices via activation of Ni nanowires to form ultrathin nanosheets and porous nanostructures. The as-designed free-standing Ni@Ni(OH) 2 film electrodes display a significantly enhanced volumetric capacity (462 C/cm 3 at 0.5 A/cm 3 ) and excellent cycle stability. Moreover, the as-developed hybrid supercapacitor employed Ni@Ni(OH) 2 film as positive electrode and graphene-carbon nanotube film as negative electrode exhibits a high volumetric capacitance of 95 F/cm 3 (at 0.25 A/cm 3 ) and excellent cycle performance (only 14% capacitance reduction for 4500 cycles). Furthermore, the volumetric energy density can reach 33.9 mWh/cm 3 , which is much higher than that of most thin film lithium batteries (1-10 mWh/cm 3 ). This work gives an insight for designing high-volume three-dimensional electrodes and paves a new way to construct binder-free film electrode for high-performance hybrid supercapacitor applications.

  3. Electrochemical performance of electrospun free-standing nitrogen-doped carbon nanofibers and their application for glucose biosensing.

    PubMed

    Liu, Dong; Zhang, Xueping; You, Tianyan

    2014-05-14

    In spite of excellent electrochemical properties, nitrogen-doped carbon nanofibers (NCNFs) have rarely been studied in the field of electroanalysis. In this work, we investigated the electrochemical properties and biosensing performance of NCNFs prepared by a newly proposed approach. The as-obtained NCNFs present a unique free-standing structure with high flexibility which could be convenient for electrode modification. Electrochemical measurements of typical redox species including [Ru(NH3)6]3+/2+, [Fe(CN)6]3-/4-, [Fe(H2O)6]3+/2+, and dopamine indicate that the NCNFs have a larger surface area and faster electron transfer rate compared with carbon nanofibers (CNFs). The presence of high content of pyrrolic-N and abundant defective sites in NCNFs leads to an obvious positive shift of peak potential for oxygen reduction at NCNFs relative to that obtained at CNFs. The unique structure and properties greatly enhance the electrochemical performance of NCNFs. The glucose biosensor based on glucose oxidase/NCNFs shows linear ranges of 0.2-1.2 mM at -0.42 V and 0.05-3 mM at 0.40 V both with high stability. These results suggest that the NCNFs could be a convenient and stable platform for electrochemical biosensors.

  4. Free-standing 3D graphene/polyaniline composite film electrodes for high-performance supercapacitors

    NASA Astrophysics Data System (ADS)

    Wang, Shiyong; Ma, Li; Gan, Mengyu; Fu, Shenna; Dai, Wenqin; Zhou, Tao; Sun, Xiaowu; Wang, Huihui; Wang, Huining

    2015-12-01

    The research paper describes polyaniline (PANI) nanowires array on flexible polystyrene microsphere/reduced graphene (PS/rGN) film is synthesized by dilute polymerization, and then the PS microspheres are removed to form free-standing three-dimensional (3D) rGN/PANI composite film. The chemical and structural properties of the 3D rGN/PANI film are characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and Brunauer-Emmett-Teller (BET), and the results confirm the 3D rGN/PANI film is synthesized successfully. When the film is used as a supercapacitor electrode, the maximum specific capacitance is as high as 740 F g-1 (or 581 F cm-3 for volumetric capacitance) at a current density of 0.5 A g-1 and the specific capacitance retains 87% of the initial after constant charge-discharge 1000 cycles at current density of 10 A g-1. It is believed that the free-standing 3D rGN/PANI film will have a great potential for application in supercapacitors.

  5. A Study of relationship between frailty and physical performance in elderly women.

    PubMed

    Jeoung, Bog Ja; Lee, Yang Chool

    2015-08-01

    Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty.

  6. Free-standing ternary NiWP film for efficient water oxidation reaction

    NASA Astrophysics Data System (ADS)

    Yang, Yunpeng; Zhou, Kuo; Ma, Lili; Liang, Yanqin; Yang, Xianjin; Cui, Zhenduo; Zhu, Shengli; Li, Zhaoyang

    2018-03-01

    High-efficient catalysts for oxygen evolution reaction (OER) is of great concern in improving energy efficiency for water splitting. Here we report a high-performance OER electrocatalyst of nickel-tungsten-phosphorus (NiWP) film prepared by template method. This free-standing ternary electrocatalyst exhibits a remarkable electrocatalytic activity of OER in alkaline medium due to the synergetic effect among these elements and the good electrical conductivity. The reported NiWP composite catalyst has an overpotential of as low as 0.4 V (vs. RHE) at 30 mA cm-2, better than that of the commercial RuO2 catalyst. Moreover, a small charge transfer resistance of 4.06 Ω and a Tafel slope of 68 mV dec-1 demonstrate the outstanding catalytic activity.

  7. Highly flexible, nonflammable and free-standing SiC nanowire paper

    NASA Astrophysics Data System (ADS)

    Chen, Jianjun; Liao, Xin; Wang, Mingming; Liu, Zhaoxiang; Zhang, Judong; Ding, Lijuan; Gao, Li; Li, Ye

    2015-03-01

    Flexible paper-like semiconductor nanowire materials are expected to meet the criteria for some emerging applications, such as components of flexible solar cells, electrical batteries, supercapacitors, nanocomposites, bendable or wearable electronic or optoelectronic components, and so on. As a new generation of wide-bandgap semiconductors and reinforcements in composites, SiC nanowires have advantages in power electronic applications and nanofiber reinforced ceramic composites. Herein, free-standing SiC nanowire paper consisting of ultralong single-crystalline SiC nanowires was prepared through a facile vacuum filtration approach. The ultralong SiC nanowires were synthesized by a sol-gel and carbothermal reduction method. The flexible paper composed of SiC nanowires is ~100 nm in width and up to several hundreds of micrometers in length. The nanowires are intertwisted with each other to form a three-dimensional network-like structure. SiC nanowire paper exhibits high flexibility and strong mechanical stability. The refractory performance and thermal stability of SiC nanowire paper were also investigated. The paper not only exhibits excellent nonflammability in fire, but also remains well preserved without visible damage when it is heated in an electric oven at a high temperature (1000 °C) for 3 h. With its high flexibility, excellent nonflammability, and high thermal stability, the free-standing SiC nanowire paper may have the potential to improve the ablation resistance of high temperature ceramic composites.Flexible paper-like semiconductor nanowire materials are expected to meet the criteria for some emerging applications, such as components of flexible solar cells, electrical batteries, supercapacitors, nanocomposites, bendable or wearable electronic or optoelectronic components, and so on. As a new generation of wide-bandgap semiconductors and reinforcements in composites, SiC nanowires have advantages in power electronic applications and nanofiber reinforced ceramic composites. Herein, free-standing SiC nanowire paper consisting of ultralong single-crystalline SiC nanowires was prepared through a facile vacuum filtration approach. The ultralong SiC nanowires were synthesized by a sol-gel and carbothermal reduction method. The flexible paper composed of SiC nanowires is ~100 nm in width and up to several hundreds of micrometers in length. The nanowires are intertwisted with each other to form a three-dimensional network-like structure. SiC nanowire paper exhibits high flexibility and strong mechanical stability. The refractory performance and thermal stability of SiC nanowire paper were also investigated. The paper not only exhibits excellent nonflammability in fire, but also remains well preserved without visible damage when it is heated in an electric oven at a high temperature (1000 °C) for 3 h. With its high flexibility, excellent nonflammability, and high thermal stability, the free-standing SiC nanowire paper may have the potential to improve the ablation resistance of high temperature ceramic composites. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr00776c

  8. Magnetic resonance studies of the Mg acceptor in thick free-standing and thin-film GaN

    NASA Astrophysics Data System (ADS)

    Zvanut, Mary Ellen

    Mg, the only effective p-type dopant for the nitrides, substitutes for Ga and forms an acceptor with a defect level of about 0.16 eV. The magnetic resonance of such a center should be highly anisotropic, yet early work employing both optically detected magnetic resonance (ODMR) and electron paramagnetic resonance (EPR) spectroscopies revealed a defect with a nearly isotropic g-tensor. The results were attributed to crystal fields caused by compensation and/or strain typical of the heteroepitaxially grown films. The theory was supported by observation of the expected highly anisotropic ODMR signature in homoepitaxially grown films in which dislocation-induced non-uniform strain and compensation are reduced. The talk will review EPR measurements of thin films and describe new work which takes advantage of the recently available thick free-standing GaN:Mg substrates grown by hydride vapor phase epitaxy (HVPE) and high nitrogen pressure solution growth (HNPS). Interestingly, the films and HVPE substrates exhibit characteristically different types of EPR signals, and no EPR response could be induced in the HNPS substrates, with or without illumination. In the heteroepitaxial films, a curious angular dependent line-shape is observed in addition to the nearly isotropic g-tensor characteristic of the Mg-related acceptor. On the other hand, the free-standing HVPE crystals reveal a clear signature of a highly anisotropic shallow acceptor center. Comparison with SIMS measurements implies a direct relation to the Mg impurity, and frequency-dependent EPR studies demonstrate the influence of the anisotropic crystal fields. Overall, the measurements of the thick free-standing crystals show that the Mg acceptor is strongly affected by the local environment. The ODMR was performed by Evan Glaser, NRL and the free-standing Mg-doped HVPE crystals were grown by Jacob Leach, Kyma Tech. The work at UAB is supported by NSF Grant No. DMR-1308446.

  9. Challenging Postural Tasks Increase Asymmetry in Patients with Parkinson’s Disease

    PubMed Central

    Beretta, Victor Spiandor; Gobbi, Lilian Teresa Bucken; Lirani-Silva, Ellen; Simieli, Lucas; Orcioli-Silva, Diego; Barbieri, Fabio Augusto

    2015-01-01

    The unilateral predominance of Parkinson’s disease (PD) symptoms suggests that balance control could be asymmetrical during static tasks. Although studies have shown that balance control asymmetries exist in patients with PD, these analyses were performed using only simple bipedal standing tasks. Challenging postural tasks, such as unipedal or tandem standing, could exacerbate balance control asymmetries. To address this, we studied the impact of challenging standing tasks on postural control asymmetry in patients with PD. Twenty patients with PD and twenty neurologically healthy individuals (control group) participated in this study. Participants performed three 30s trials for each postural task: bipedal, tandem adapted and unipedal standing. The center of pressure parameter was calculated for both limbs in each of these conditions, and the asymmetry between limbs was assessed using the symmetric index. A significant effect of condition was observed, with unipedal standing and tandem standing showing greater asymmetry than bipedal standing for the mediolateral root mean square (RMS) and area of sway parameters, respectively. In addition, a group*condition interaction indicated that, only for patients with PD, the unipedal condition showed greater asymmetry in the mediolateral RMS and area of sway than the bipedal condition and the tandem condition showed greater asymmetry in the area of sway than the bipedal condition. Patients with PD exhibited greater asymmetry while performing tasks requiring postural control when compared to neurologically healthy individuals, especially for challenging tasks such as tandem and unipedal standing. PMID:26367032

  10. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    PubMed Central

    Silva, Paula F. S.; Quintino, Ludmylla F.; Franco, Juliane; Faria, Christina D. C. M.

    2014-01-01

    Background Subjects with neurological disease (ND) usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. Objective To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. Method A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro) were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. Results Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99) for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99) for stroke and inter-rater reliability (ICC=0.99) for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77), and the feasibility and safety were good for subjects with Alzheimer's disease. Conclusions The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement properties were investigated and showed adequate results. PMID:24839043

  11. a High Frequency Thermoacoustically-Driven Pulse Tube Cryocooler with Coaxial Resonator

    NASA Astrophysics Data System (ADS)

    Yu, G. Y.; Wang, X. T.; Dai, W.; Luo, E. C.

    2010-04-01

    High frequency thermoacoustically-driven pulse tube cryocoolers are quite promising due to their compact size and high reliability, which can find applications in space use. With continuous effort, a lowest cold head temperature of 68.3 K has been obtained on a 300 Hz pulse tube cryocooler driven by a standing-wave thermoacoustic heat engine with 4.0 MPa helium gas and 750 W heat input. To further reduce the size of the system, a coaxial resonator was designed and the two sub-systems, i.e., the pulse tube cryocooler and the standing-wave thermoacoustic heat engine were properly coupled through an acoustic amplifier tube, which leads to a system axial length of only about 0.7 m. The performance of the system with the coaxial resonator was tested, and shows moderate degradation compared to that with the in-line resonator, which might be attributed to the large flow loss of the 180 degree corner.

  12. High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator

    NASA Astrophysics Data System (ADS)

    Park, Sae-Hoon; Kim, Yu-Seok

    2015-10-01

    The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.

  13. Orientation-dependent energy level alignment and film growth of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on HOPG

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyu, Lu; Niu, Dongmei, E-mail: mayee@csu.edu.cnmailto; Xie, Haipeng

    Combining ultraviolet photoemission spectroscopy, X-ray photoemission spectroscopy, atomic force microscopy, and X-ray diffraction measurements, we performed a systematic investigation on the correlation of energy level alignment, film growth, and molecular orientation of 2,7-diocty[1]benzothieno[3,2-b]benzothiophene (C8-BTBT) on highly oriented pyrolytic graphite. The molecules lie down in the first layer and then stand up from the second layer. The ionization potential shows a sharp decrease from the lying down region to the standing up region. When C8-BTBT molecules start standing up, unconventional energy level band-bending-like shifts are observed as the film thickness increases. These shifts are ascribed to gradual decreasing of the molecularmore » tilt angle about the substrate normal with the increasing film thickness.« less

  14. Communicating through humour: A project of stand-up comedy about science.

    PubMed

    Pinto, Bruno; Marçal, David; Vaz, Sofia G

    2015-10-01

    A study of a project on science stand-up comedy developed in Portugal between 2009 and 2013 is presented, in which thirteen scientists, coordinated by a science communicator and a professional actor, created and presented comedy acts. Eleven of these scientists were asked about their motivations to participate, the process of performance development and the perceived value of the project. Personal motivations were highly important, but professional reasons were also mentioned. Working in a group with the guidance of coordinators, testing and re-writing the texts and gradually gaining confidence on stage were considered fundamental in the development of the shows. Additionally, a questionnaire revealed that the audience, most of whom were young adults, and held a higher education degree, were satisfied with the show. Overall, both participating scientists and audience members considered that stand-up comedy has potential for science communication. © The Author(s) 2013.

  15. DNA translocation measurements in solid-state nanopores fabricated using helium-ion microscope

    NASA Astrophysics Data System (ADS)

    Liu, Liping; Miao, Wang; Huynh, Chuong; Liu, Quanjun; Ling, Xinsheng

    2012-02-01

    We report high-quality DNA translocation measurements in solid-state nanopores drilled in free-standing SiN membranes by using a helium-ion beam in a Zeiss helium-ion microscope (HIM). We show that the HIM nanopores have similar performance as the TEM-drilled pores.

  16. Forest Stands Selected by Foraging Red-Cockaded Woodpeckers

    Treesearch

    Robert G. Hooper; Richard F. Harlow

    1986-01-01

    Selection of forest stands by 18 clans of foraging red-cockaded woodpeckers was studied in their year-round home ranges. The foraging use of 276 stands relative to their availability within the home ranges was compared to several stand characteristics. Selection among stands with similar characteristics was highly vairable and red-cockadeds foraged in stands with a...

  17. Clinical Rating of Movement-Pattern Quality in Patients With Femoroacetabular Impingement Syndrome: A Methodological Study.

    PubMed

    Casartelli, Nicola C; Maffiuletti, Nicola A; Brunner, Romana; Büchi, Marcel; Sutter, Reto; Pfirrmann, Christian W; Naal, Florian D; Leunig, Michael; Bizzini, Mario

    2018-04-01

    Study Design Cross-sectional study. Objectives To evaluate intrarater and interrater agreement among physical therapists with different clinical experience in performing a visual rating of movement-pattern quality of patients with femoroacetabular impingement (FAI) syndrome using a semi-quantitative scale. Background Visual rating of movement patterns in patients with FAI syndrome is of interest, because poor control of dynamic hip motion is frequently noted. Methods A video camera was used to record the performance of 34 patients with FAI syndrome performing single-limb standing, squat, frontal lunge, hop lunge, bridge, and plank. Visual rating of movement, as recorded on video, was performed by a highly experienced, a moderately experienced, and a novice physical therapist on 2 occasions using a semi-quantitative scale. Hip abductor strength was assessed using dynamometry, and hip pain and function were assessed with a patient-reported questionnaire. Intrarater and interrater agreement among physical therapists was evaluated using Gwet's agreement coefficient 1. Construct validity was evaluated as the association between physical therapists' rating and patients' hip abductor strength, pain, and function. Results Good intrarater and interrater agreement was observed in the highly experienced and moderately experienced physical therapists when rating single-limb standing, bridge, and plank. Poor to moderate intrarater and interrater agreement was found when they rated squat, frontal lunge, and hop lunge. Poor performers, as rated by the highly experienced physical therapist only, demonstrated lower hip abductor strength (P<.05), and similar hip pain and hip function compared to those of good performers. Conclusion Movement-pattern quality of patients with FAI syndrome should be rated by a highly experienced physical therapist. J Orthop Sports Phys Ther 2018;48(4):260-269. doi:10.2519/jospt.2018.7840.

  18. Magnetic field measurements near stand-alone transformer stations.

    PubMed

    Kandel, Shaiela; Hareuveny, Ronen; Yitzhak, Nir-Mordechay; Ruppin, Raphael

    2013-12-01

    Extremely low-frequency (ELF) magnetic field (MF) measurements around and above three stand-alone 22/0.4-kV transformer stations have been performed. The low-voltage (LV) cables between the transformer and the LV switchgear were found to be the major source of strong ELF MFs of limited spatial extent. The strong fields measured above the transformer stations support the assessment method, to be used in future epidemiological studies, of classifying apartments located right above the transformer stations as highly exposed to MFs. The results of the MF measurements above the ground around the transformer stations provide a basis for the assessment of the option of implementing precautionary procedures.

  19. Nine-year performance of four hardwoods on a harvested site with and without fertilizer tree shelters, and weed mats in southern Illinois

    Treesearch

    Felix, Jr. Ponder; J.W. Van Sambeek

    2013-01-01

    Quality hardwood species often dominate stands on intermediate to high quality sites before regeneration. However, successfully regenerating these species after the harvest is rarely achieved on these sites. Hardwood species were planted on a high quality site in southern Illinois after clearcutting to study the effect of several cultural practices on the hardwoods...

  20. Changes in motor skill and fitness measures among children with high and low motor competence: a five-year longitudinal study.

    PubMed

    Hands, Beth

    2008-04-01

    Children with low motor competence (LMC) are less able to participate fully in many sports and recreational activities typically enjoyed by their well-coordinated peers. Poor fitness outcomes have been reported for these children, although previous studies have not tracked these outcomes over time. In this study, 19 children (8 girls and 11 boys) with LMC aged between 5 and 7years were matched by age and gender with 19 children with high motor competence (HMC). Six fitness (body composition and cardiovascular endurance) and motor skill (sprint run, standing broad jump and balance) measures were repeated for each group once a year for five years. For each year of the study, the LMC groups performed less well on all measures than the HMC groups. Changes over time were significantly different between groups for cardiovascular endurance, 50-m run and balance, but not for body composition, overhand throw or standing broad jump. Between the two groups, performances were significantly different for all measures, except body composition. These findings confirm the impact of LMC on fitness measures and skill performances over time.

  1. Stabilisation times after transitions to standing from different working postures.

    PubMed

    DiDomenico, Angela; McGorry, Raymond W; Banks, Jacob J

    2016-10-01

    Transitioning to standing after maintaining working postures may result in imbalance and could elicit a fall. The objective of this study was to quantify the magnitude of imbalance using a stabilisation time metric. Forty-five male participants completed three replications of conditions created by one of four working postures (bent at waist, squat, forward kneel, reclined kneel) and three durations within posture. Participants transitioned to quiet standing at a self-selected pace. Stabilisation time, based on changes in centre of pressure velocity, was used to indicate the initiation of steady state while standing. Stabilisation time was significantly affected by static postures but not duration within posture. The largest stabilisation times resulted from transitions initiated from a bent at waist posture. The smallest were associated with the kneeling postures, which were not significantly different from each other. Findings may lead to recommendations for redesign of tasks, particularly in high-risk environments such as construction. Statement of Relevance: Task performance on the jobsite often requires individuals to maintain non-erect postures. This study suggests that working posture affects stabilisation during transition to a standing position. Bending at the waist and squatting resulted in longer stabilisation times, whereas both kneeling postures evaluated resulted in greater imbalance but for a shorter duration.

  2. Inability to Perform the Repeated Chair Stand Task Predicts Fall-Related Injury in Older Primary Care Patients.

    PubMed

    Shea, Cristina A; Ward, Rachel E; Welch, Sarah A; Kiely, Dan K; Goldstein, Richard; Bean, Jonathan F

    2018-06-01

    The aim of the study was to examine whether the chair stand component of the Short Physical Performance Battery predicts fall-related injury among older adult primary care patients. A 2-yr longitudinal cohort study of 430 Boston-area primary care patients aged ≥65 yrs screened to be at risk for mobility decline was conducted. The three components of the Short Physical Performance Battery (balance time, gait speed, and chair stand time) were measured at baseline. Participants reported incidence of fall-related injuries quarterly for 2 yrs. Complementary log-log discrete time hazard models were constructed to examine the hazard of fall-related injury across Short Physical Performance Battery scores, adjusting for age, sex, race, Digit Symbol Substitution Test score, and fall history. Participants were 68% female and 83% white, with a mean (SD) age of 76.6 (7.0). A total of 137 (32%) reported a fall-related injury during the follow-up period. Overall, inability to perform the chair stand task was a significant predictor of fall-related injury (hazard ratio = 2.11, 95% confidence interval = 1.23-3.62, P = 0.01). Total Short Physical Performance Battery score, gait component score, and balance component score were not predictive of fall-related injury. Inability to perform the repeated chair stand task was associated with increased hazard of an injurious fall for 2 yrs among a cohort of older adult primary care patients.

  3. Effect of calendar age on physical performance: A comparison of standard clinical measures with instrumented measures in middle-aged to older adults.

    PubMed

    Stijntjes, M; Meskers, C G M; de Craen, A J M; van Lummel, R C; Rispens, S M; Slagboom, P E; Maier, A B

    2016-03-01

    Decline in physical performance is highly prevalent during aging. Identification of sensitive markers of age-related changes in physical performance is important for early detection, development of therapeutic strategies and insight into underlying mechanisms. We studied the association of calendar age and familial longevity with standard clinical and instrumented measures of physical performance in a cohort of healthy middle-aged to older adults. Cross-sectional analysis within the Leiden Longevity Study consisting of offspring of nonagenarian siblings and their partners (n=300, mean age (SD) 65.3 (6.7) years). Standard clinical measures were 25-meter walking speed and total duration of the chair stand test (CST). Instrumented measures were determined using a body fixed sensor. Dependence of physical performance on calendar age and familial longevity (offspring versus partner status) was analyzed using linear and logistic regression, respectively, adjusted for gender and height. Higher calendar age was associated with slower walking speed and longer duration of the CST (standardized β (95% CI) -.024 (-.042; -.006) and .035 (.014;.056), respectively). Instrumented measures showed similar effect sizes with strongest associations for gait stability and symmetry in mediolateral direction and for the extension and flexion phase of sit-to-stand and stand-to-sit transfers, respectively. No differences were observed between offspring of nonagenarian siblings and their partners. Standard clinical and instrumented measures of physical performance are associated with similar effect size to age-related changes in physical performance observable from middle age. The potential added value of instrumented measures for understanding underlying mechanisms requires further attention. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Active bialkali photocathodes on free-standing graphene substrates

    DOE PAGES

    Yamaguchi, Hisato; Liu, Fangze; DeFazio, Jeffrey; ...

    2017-06-01

    Here, the hexagonal structure of graphene gives rise to the property of gas impermeability, motivating its investigation for a new application: protection of semiconductor photocathodes in electron accelerators. These materials are extremely susceptible to degradation in efficiency through multiple mechanisms related to contamination from the local imperfect vacuum environment of the host photoinjector. Few-layer graphene has been predicted to permit a modified photoemission response of protected photocathode surfaces, and recent experiments of single-layer graphene on copper have begun to confirm these predictions for single crystal metallic photocathodes. Unlike metallic photoemitters, the integration of an ultra-thin graphene barrier film with conventionalmore » semiconductor photocathode growth processes is not straightforward. A first step toward addressing this challenge is the growth and characterization of technologically relevant, high quantum efficiency bialkali photocathodes on ultra-thin free-standing graphene substrates. Photocathode growth on free-standing graphene provides the opportunity to integrate these two materials and study their interaction. Specifically, spectral response features and photoemission stability of cathodes grown on graphene substrates are compared to those deposited on established substrates. In addition, we observed an increase of work function for the graphene encapsulated bialkali photocathode surfaces, which is predicted by our calculations. The results provide a unique demonstration of bialkali photocathodes on free-standing substrates, and indicate promise towards our goal of fabricating high-performance graphene encapsulated photocathodes with enhanced lifetime for accelerator applications.« less

  5. Active bialkali photocathodes on free-standing graphene substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamaguchi, Hisato; Liu, Fangze; DeFazio, Jeffrey

    Here, the hexagonal structure of graphene gives rise to the property of gas impermeability, motivating its investigation for a new application: protection of semiconductor photocathodes in electron accelerators. These materials are extremely susceptible to degradation in efficiency through multiple mechanisms related to contamination from the local imperfect vacuum environment of the host photoinjector. Few-layer graphene has been predicted to permit a modified photoemission response of protected photocathode surfaces, and recent experiments of single-layer graphene on copper have begun to confirm these predictions for single crystal metallic photocathodes. Unlike metallic photoemitters, the integration of an ultra-thin graphene barrier film with conventionalmore » semiconductor photocathode growth processes is not straightforward. A first step toward addressing this challenge is the growth and characterization of technologically relevant, high quantum efficiency bialkali photocathodes on ultra-thin free-standing graphene substrates. Photocathode growth on free-standing graphene provides the opportunity to integrate these two materials and study their interaction. Specifically, spectral response features and photoemission stability of cathodes grown on graphene substrates are compared to those deposited on established substrates. In addition, we observed an increase of work function for the graphene encapsulated bialkali photocathode surfaces, which is predicted by our calculations. The results provide a unique demonstration of bialkali photocathodes on free-standing substrates, and indicate promise towards our goal of fabricating high-performance graphene encapsulated photocathodes with enhanced lifetime for accelerator applications.« less

  6. Regulating Stand Density by Precommercial Thinning in Naturally Regenerated Loblolly Pine Stands: Evaluation of Management and Economic Opportunities

    Treesearch

    David J. Moorhead; Coleman W. Dangerfield; M. Boyd Edwards

    1997-01-01

    The economic performance of converting 13-year-old, overstocked (>3,000 trees per acre), naturally regenerated pine stands using precommercial thinning at a cost of $140 per acre was modeled for 25-, 35-, and 50-year rotations. The stand density was reduced to 283 trees per acre. Subsequent management scenarios recovered establishment and management costs through...

  7. Cross-cultural adaptation, reliability and validity of the Turkish version of the Hospital for Special Surgery (HSS) Knee Score.

    PubMed

    Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi

    2014-01-01

    The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.

  8. High Rates of Gene Flow by Pollen and Seed in Oak Populations across Europe

    PubMed Central

    Gerber, Sophie; Chadœuf, Joël; Gugerli, Felix; Lascoux, Martin; Buiteveld, Joukje; Cottrell, Joan; Dounavi, Aikaterini; Fineschi, Silvia; Forrest, Laura L.; Fogelqvist, Johan; Goicoechea, Pablo G.; Jensen, Jan Svejgaard; Salvini, Daniela; Vendramin, Giovanni G.; Kremer, Antoine

    2014-01-01

    Gene flow is a key factor in the evolution of species, influencing effective population size, hybridisation and local adaptation. We analysed local gene flow in eight stands of white oak (mostly Quercus petraea and Q. robur, but also Q. pubescens and Q. faginea) distributed across Europe. Adult trees within a given area in each stand were exhaustively sampled (range [239, 754], mean 423), mapped, and acorns were collected ([17,147], 51) from several mother trees ([3], [47], 23). Seedlings ([65,387], 178) were harvested and geo-referenced in six of the eight stands. Genetic information was obtained from screening distinct molecular markers spread across the genome, genotyping each tree, acorn or seedling. All samples were thus genotyped at 5–8 nuclear microsatellite loci. Fathers/parents were assigned to acorns and seedlings using likelihood methods. Mating success of male and female parents, pollen and seed dispersal curves, and also hybridisation rates were estimated in each stand and compared on a continental scale. On average, the percentage of the wind-borne pollen from outside the stand was 60%, with large variation among stands (21–88%). Mean seed immigration into the stand was 40%, a high value for oaks that are generally considered to have limited seed dispersal. However, this estimate varied greatly among stands (20–66%). Gene flow was mostly intraspecific, with large variation, as some trees and stands showed particularly high rates of hybridisation. Our results show that mating success was unevenly distributed among trees. The high levels of gene flow suggest that geographically remote oak stands are unlikely to be genetically isolated, questioning the static definition of gene reserves and seed stands. PMID:24454802

  9. Evaluation of the ICET Test Stand to Assess the Performance of a Range of Ceramic Media Filter Elements in Support of ASME AG-1 Subsection FO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schemmel, A.

    High Efficiency Particulate Air (HEPA) filters are defined as extended-medium, dry-type filters with: (1) a minimum particle removal efficiency of no less than 99.97 percent for 0.3 micrometer particles, (2) a maximum, clean resistance of 1.0 inch water column (in. WC) when operated at 1,000 cubic feet per minute (CFM), and (3) a rigid casing that extends the full depth of the medium. Specifically, ceramic media HEPA filters provide better performance at elevated temperatures, are moisture resistant and nonflammable, can perform their function if wetted and exposed to greater pressures, and can be cleaned and reused. This paper describes themore » modification and design of a large scale test stand which properly evaluates the filtration characteristics of a range of ceramic media filters challenged with a nuclear aerosol agent in order to develop Section FO of ASME AG-1.« less

  10. Multiple degree-of-freedom force and moment measurement for static propulsion testing using magnetic suspension technology

    NASA Technical Reports Server (NTRS)

    Stuart, Keith; Bartosh, Blake

    1993-01-01

    Innovative Information Systems (IIS), Inc. is in the process of designing and fabricating a high bandwidth force and moment measuring device (i.e. the Magnetic Thruster Test Stand). This device will use active magnetic suspension to allow direct measurements of the forces and torques generated by the rocket engines of the missile under test. The principle of operation of the Magnetic Thruster Test Stand (MTTS) is based on the ability to perform very precise, high bandwidth force and position measurements on an object suspended in a magnetic field. This ability exists due to the fact that the digital servo control mechanism that performs the magnetic suspension uses high bandwidth (10 kHz) position data (via an eddy-current proximity sensor) to determine the amount of force required to maintain stable suspension at a particular point. This force is converted into required electromagnet coil current, which is then output to a current amplifier driving the coils. A discussion of how the coil current and magnetic gap distance (the distance between the electromagnet and the object being suspended) is used to determine the forces being applied from the suspended assembly is presented.

  11. Contributions to lateral balance control in ambulatory older adults.

    PubMed

    Sparto, Patrick J; Newman, A B; Simonsick, E M; Caserotti, P; Strotmeyer, E S; Kritchevsky, S B; Yaffe, K; Rosano, C

    2018-06-01

    In older adults, impaired control of standing balance in the lateral direction is associated with the increased risk of falling. Assessing the factors that contribute to impaired standing balance control may identify areas to address to reduce falls risk. To investigate the contributions of physiological factors to standing lateral balance control. Two hundred twenty-two participants from the Pittsburgh site of the Health, Aging and Body Composition Study had lateral balance control assessed using a clinical sensory integration balance test (standing on level and foam surface with eyes open and closed) and a lateral center of pressure tracking test using visual feedback. The center of pressure was recorded from a force platform. Multiple linear regression models examined contributors of lateral control of balance performance, including concurrently measured tests of lower extremity sensation, knee extensor strength, executive function, and clinical balance tests. Models were adjusted for age, body mass index, and sex. Larger lateral sway during the sensory integration test performed on foam was associated with longer repeated chair stands time. During the lateral center of pressure tracking task, the error in tracking increased at higher frequencies; greater error was associated with worse executive function. The relationship between sway performance and physical and cognitive function differed between women and men. Contributors to control of lateral balance were task-dependent. Lateral standing performance on an unstable surface may be more dependent upon general lower extremity strength, whereas visual tracking performance may be more dependent upon cognitive factors. Lateral balance control in ambulatory older adults is associated with deficits in strength and executive function.

  12. iPhone Sensors in Tracking Outcome Variables of the 30-Second Chair Stand Test and Stair Climb Test to Evaluate Disability: Cross-Sectional Pilot Study.

    PubMed

    Adusumilli, Gautam; Joseph, Solomon Eben; Samaan, Michael A; Schultz, Brooke; Popovic, Tijana; Souza, Richard B; Majumdar, Sharmila

    2017-10-27

    Performance tests are important to characterize patient disabilities and functional changes. The Osteoarthritis Research Society International and others recommend the 30-second Chair Stand Test and Stair Climb Test, among others, as core tests that capture two distinct types of disability during activities of daily living. However, these two tests are limited by current protocols of testing in clinics. There is a need for an alternative that allows remote testing of functional capabilities during these tests in the osteoarthritis patient population. Objectives are to (1) develop an app for testing the functionality of an iPhone's accelerometer and gravity sensor and (2) conduct a pilot study objectively evaluating the criterion validity and test-retest reliability of outcome variables obtained from these sensors during the 30-second Chair Stand Test and Stair Climb Test. An iOS app was developed with data collection capabilities from the built-in iPhone accelerometer and gravity sensor tools and linked to Google Firebase. A total of 24 subjects performed the 30-second Chair Stand Test with an iPhone accelerometer collecting data and an external rater manually counting sit-to-stand repetitions. A total of 21 subjects performed the Stair Climb Test with an iPhone gravity sensor turned on and an external rater timing the duration of the test on a stopwatch. App data from Firebase were converted into graphical data and exported into MATLAB for data filtering. Multiple iterations of a data processing algorithm were used to increase robustness and accuracy. MATLAB-generated outcome variables were compared to the manually determined outcome variables of each test. Pearson's correlation coefficients (PCCs), Bland-Altman plots, intraclass correlation coefficients (ICCs), standard errors of measurement, and repeatability coefficients were generated to evaluate criterion validity, agreement, and test-retest reliability of iPhone sensor data against gold-standard manual measurements. App accelerometer data during the 30-second Chair Stand Test (PCC=.890) and gravity sensor data during the Stair Climb Test (PCC=.865) were highly correlated to gold-standard manual measurements. Greater than 95% of values on Bland-Altman plots comparing the manual data to the app data fell within the 95% limits of agreement. Strong intraclass correlation was found for trials of the 30-second Chair Stand Test (ICC=.968) and Stair Climb Test (ICC=.902). Standard errors of measurement for both tests were found to be within acceptable thresholds for MATLAB. Repeatability coefficients for the 30-second Chair Stand Test and Stair Climb Test were 0.629 and 1.20, respectively. App-based performance testing of the 30-second Chair Stand Test and Stair Climb Test is valid and reliable, suggesting its applicability to future, larger-scale studies in the osteoarthritis patient population. ©Gautam Adusumilli, Solomon Eben Joseph, Michael A Samaan, Brooke Schultz, Tijana Popovic, Richard B Souza, Sharmila Majumdar. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 27.10.2017.

  13. Physical Performance and Serum 25(OH)vitamin D Status in Community Dwelling Old Mobility Limited Adults: A Cross-Sectional Study.

    PubMed

    von Berens, Å; Cederholm, T; Fielding, R A; Gustafsson, T; Kirn, D; Laussen, J; Nydahl, M; Travison, T G; Reid, K; Koochek, A

    2018-01-01

    To examine the potential association between serum 25(OH) vitamin D and the performance on the Short Physical Performance Battery (SPPB) including the sub-components; five repeated chair stands test, 4 meters walk test and balance in older mobility-limited community-dwelling men and women. A cross sectional study was performed in American and Swedish subjects who were examined for potential participation in a combined exercise and nutrition intervention trial. Logistic regression analysis and linear regression analyses were performed to evaluate the association for 25(OH)D with the overall score on the SBBP, chair stand, gait speed and balance. Community-dwelling (mean age 77.6 ± 5.3 years) mobility limited American (n=494) and Swedish (n=116) females (59%) and males. The SPPB (0-12 points) includes chair stand (s), gait speed (m/s) and a balance test. Mobility limitation i.e., SPPB score ≤ 9 was an inclusion criterion. A blood sample was obtained to measure serum 25(OH)vitamin D concentrations. No clear association of 25(OH)D with SPPB scores was detected either when 25(OH)D was assessed as a continuous variable or when categorized according to serum concentrations of <50, 50-75 or <75 nmol/L. However, when analyzing the relationship between 25(OH)D and seconds to perform the chair stands, a significant quadratic relationship was observed. Thus, at serum levels of 25(OH)D above 74 nmol/L, higher concentrations appeared to be advantageous for the chair stand test, whereas for serum levels below 74 nmol/L this association was not observed. This cross- sectional study lacked clear association between serum 25(OH)D and physical performance in mobility limited adults. A potentially interesting observation was that at higher serum levels of 25(OH)D a better performance on the chair stand test was indicated.

  14. Fabrication of thickness controllable free-standing sandwich-structured hybrid carbon film for high-rate and high-power supercapacitor

    PubMed Central

    Wei, Helin; Wei, Sihang; Tian, Weifeng; Zhu, Daming; Liu, Yuhao; Yuan, Lili; Li, Xin

    2014-01-01

    Hybrid carbon films composed of graphene film and porous carbon film may give full play to the advantages of both carbon materials, and have great potential for application in energy storage and conversion devices. Unfortunately, there are very few reports on fabrication of hybrid carbon films. Here we demonstrate a simple approach to fabricate free-standing sandwich-structured hybrid carbon film composed of porous amorphous carbon film and multilayer graphene film by chemical vapor deposition in a controllable and scalable way. Hybrid carbon films reveal good electrical conductivity, excellent flexibility, and good compatibility with substrate. Supercapacitors assembled by hybrid carbon films exhibit ultrahigh rate capability, wide frequency range, good capacitance performance, and high-power density. Moreover, this approach may provide a general path for fabrication of hybrid carbon materials with different structures by using different metals with high carbon solubility, and greatly expands the application scope of carbon materials. PMID:25394410

  15. Worse self-reported outcomes but no limitations in performance-based measures in patients with long-standing hip and groin pain compared with healthy controls.

    PubMed

    Wörner, Tobias; Sigurðsson, Haraldur B; Pålsson, Anders; Kostogiannis, Ioannis; Ageberg, Eva

    2017-01-01

    This study aimed to evaluate patient-reported outcomes as well as lower extremity and trunk muscle function in patients with long-standing hip and groin pain, in comparison with matched, healthy controls. It was hypothesized that patients with long-standing hip and groin pain would report more deficiency on the Copenhagen Hip and Groin Outcome Score (HAGOS) and have worse outcomes on performance-based measures than healthy controls. Nineteen patients with long-standing hip and groin pain and 19 healthy, activity level-, age-, gender-, and weight-matched controls were assessed with the HAGOS for self-reported outcomes, and a parallel squat (w/kg), single-leg triple jump (cm), single-leg rise (n), barbell roll-out (% of height), and plank test (s) for performance-based measures. Independent sample t test was performed to assess between-group differences. The paired t test was used to analyse between-limb differences in unilateral performance tasks. The patients had worse scores than the controls in all HAGOS subscales (p ≤ 0.001), while no statistically significant differences were observed for any performance measure between groups or between symptomatic and non-symptomatic limbs. Despite significant self-reported functional limitations on the HAGOS, there were no significant differences between groups in performance-based strength or power measures. The results of this study highlight the need to identify performance-based measures, sensitive to functional deficiencies in patients with long-standing hip and groin pain in order to complement the clinical picture obtained by patient-reported outcomes such as the HAGOS. III.

  16. Osteoporosis and gait and balance disturbances in older sarcopenic obese New Zealanders.

    PubMed

    Waters, D L; Hale, L; Grant, A M; Herbison, P; Goulding, A

    2010-02-01

    Bone, muscle, and fat may affect gait and balance in older adults. Osteoporosis was prevalent in low muscle mass participants and related to gait and balance deficits. Low muscle combined with high fat mass had more functional deficits and poorer bone health, which has implications for falls risk and fractures. Decreasing bone density and muscle mass and increasing fat mass may act synergistically to affect gait and balance in older adults. One hundred eighty-three older adults (age 72.7 +/- 6 years, range 56-93; body mass index 28.2 +/- 4.9, range 16.6-46.0) were recruited from a New Zealand falls prevention intervention trial. Total and appendicular skeletal muscle mass (ASM), percent fat, and bone mineralization were assessed by dual energy X-ray absorptiometry and used to characterize normal lean (NL, n = 51), sarcopenic (SS, n = 18), sarcopenic obese (SO, n = 29), and obese (OO, n = 85) phenotypes. Functional performance was assessed using timed up and go, chair stand, single leg stand, and step test. Regression models were adjusted for age, sex, medications, and physical activity. Femoral neck osteoporosis was present in 22% SS, 17% SO, 12% NL, and 7% OO. Femoral neck osteoporosis with low ASM predicted poor chair stand performance (beta -3.3, standard error 1.6, p = 0.04). SO scored lowest on the chair stand (p = 0.03) and step test (p = 0.03). Higher ASM predicted faster timed up and go performance (p = 0.001). Osteoporosis was prevalent in low ASM groups (SS and SO) and related to gait and balance deficits, particularly in the SO. This has implications for falls risk, fractures, and interventions.

  17. Muscle activity of the core during bilateral, unilateral, seated and standing resistance exercise.

    PubMed

    Saeterbakken, Atle Hole; Fimland, Marius Steiro

    2012-05-01

    Little is known about the effect of performing common resistance exercises standing compared to seated and unilaterally compared to bilaterally on muscle activation of the core. Thus, the purpose of this study was to compare the electromyographic activity (EMG) of the superficial core muscles (i.e. rectus abdominis, external oblique and erector spinae) between seated, standing, bilateral and unilateral dumbbell shoulder presses. 15 healthy males performed five repetitions at 80% of one-repetition maximum of the exercises in randomized order. Results were analyzed with a two-way analysis of variance and a Bonferroni post hoc test. The position × exercise interaction was significantly different for rectus abdominis (P = 0.016), but not for external oblique (P = 0.100) and erector spinae (P = 0.151). The following EMG results were observed: For rectus abdominis: ~49% lower in seated bilateral versus unilateral (P < 0.001), similar in standing bilateral versus unilateral (P = 0.408), ~81% lower in bilateral seated versus standing (P < 0.001), ~59% lower in unilateral seated versus standing (P < 0.001); For external oblique: ~81% lower in seated bilateral versus unilateral (P < 0.001), ~68% lower in standing bilateral than unilateral (P < 0.001), ~58% lower in bilateral seated versus standing (P < 0.001), ~28% lower in unilateral seated versus standing (P = 0.002); For erector spinae: similar in seated bilateral versus unilateral (P = 0.737), ~18% lower in standing bilateral versus unilateral (P = 0.001), similar in seated versus standing bilateral (P = 0.480) and unilateral (P = 0.690). In conclusion, to enhance neuromuscular activation of the superficial core muscles, standing exercises should be used instead of seated exercises, and unilateral exercises should be used instead of bilateral exercises.

  18. Stand density, stand structure, and species composition in transition oak stands of northwestern Pennsylvania

    Treesearch

    S.L. Stout

    1991-01-01

    Transition stands, those containing species associated with both the northern hardwood and oak-hickory forest types, are important to forest diversity in northwestern Pennsylvania. These stands have high value for a variety of forest uses, including timber production, wildlife habitat, and aesthetics. Diameter distributions are characteristically stratified by species...

  19. Office ergonomics training and a sit-stand workstation: effects on musculoskeletal and visual symptoms and performance of office workers.

    PubMed

    Robertson, Michelle M; Ciriello, Vincent M; Garabet, Angela M

    2013-01-01

    Work Related Musculoskeletal Disorders (WMSDs) among office workers with intensive computer use is widespread and the prevalence of symptoms is growing. This randomized controlled trial investigated the effects of an office ergonomics training combined with a sit-stand workstation on musculoskeletal and visual discomfort, behaviors and performance. Participants performed a lab-based customer service job for 8 h per day, over 15 days and were assigned to: Ergonomics Trained (n = 11) or Minimally Trained (n = 11). The training consisted of: a 1.5-h interactive instruction, a sit/stand practice period, and ergonomic reminders. Ergonomics Trained participants experienced minimal musculoskeletal and visual discomfort across the 15 days, varied their postures, with significantly higher performance compared to the Minimally Trained group who had a significantly higher number of symptoms, suggesting that training plays a critical role. The ability to mitigate symptoms, change behaviors and enhance performance through training combined with a sit-stand workstation has implications for preventing discomforts in office workers. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. N2-fixation dynamics during ecosystem recovery in longleaf pine savannas

    NASA Astrophysics Data System (ADS)

    Tierney, J. A.

    2016-12-01

    Biological nitrogen fixation (BNF) can alleviate nitrogen (N) deficiencies that inhibit ecosystem recovery. BNF may be particularly important in ecosystems recovering from land-use change and perturbations from fire, as these disturbances can exacerbate N limitation. Here, we investigated how BNF dynamics change throughout ecosystem development in restored longleaf pine savannas, and how BNF responds to fire. We conducted this study in 59 1-ha plots of longleaf pine distributed across gradients of stand age and fire frequency at two sites in the southeastern US. We determined BNF contributions by three functional groups of N2-fixers (herbaceous legumes, biological soil crusts, and asymbiotic N2-fixing bacteria) by quantifying their abundances, assessing nitrogenase activity, and scaling these estimates up to the plot-level. To determine aboveground N demands, we measured tree growth using diameter increments and allometric equations paired with tissue-specific N concentrations. We fit linear models to evaluate the effects of stand age and time since fire on BNF and N demands throughout stand development, and performed separate analyses on mature stands to determine how fire return interval affects BNF. We observed distinct temporal patterns of N2-fixation across stand development among the three groups of N2 fixers. N2-fixation by legumes and asymbiotic bacteria remained low until stands reached maturity, while N2-fixation by biological soil crusts (BSCs) was high in juvenile stands and decreased with stand age. These patterns suggest a compensatory shift in the importance of these functional groups throughout stand development such that contributions from BSCs are critical for meeting N demands when disturbances may hinder the establishment of legumes and asymbiotic bacteria. N2-fixation by BSCs and asymbiotic bacteria throughout stand development was not affected by time since fire, but legume abundance increased the year following fire, suggesting a recovery mechanism provided by this group. Our findings suggest that BSCs are the most important source of new N in the early phases of ecosystem restoration. In contrast, legumes appear to be critical in mature longleaf pine stands that burn frequently, and particularly for supplying new N in the year following a fire event.

  1. A combination of clinical balance measures and FRAX® to improve identification of high-risk fallers.

    PubMed

    Najafi, David A; Dahlberg, Leif E; Hansson, Eva Ekvall

    2016-05-03

    The FRAX® algorithm quantifies a patient's 10-year probability of a hip or major osteoporotic fracture without taking an individual's balance into account. Balance measures assess the functional ability of an individual and the FRAX® algorithm is a model that integrates the individual patients clinical risk factors [not balance] and bone mineral density. Thus, clinical balance measures capture aspects that the FRAX® algorithm does not, and vice versa. It is therefore possible that combining FRAX® and clinical balance measures can improve the identification of patients at high fall risk and thereby high fracture risk. Our study aim was to explore whether there is an association between clinical balance measures and fracture prediction obtained from FRAX®. A cross-sectional study design was used where post hoc was performed on a dataset of 82 participants (54 to 89 years of age, mean age 71.4, 77 female), with a fall-related wrist-fracture between 2008 and 2012. Balance was measured by tandem stance, standing one leg, walking in the figure of eight, walking heel to toe on a line, walking as fast as possible for 30 m and five times sit to stand balance measures [tandem stance and standing one leg measured first with open and then with closed eyes] and each one analyzed for bivariate relations with the 10-year probability values for hip and major osteoporotic fractures as calculated by FRAX® using Spearman's rank correlation test. Individuals with high FRAX® values had poor outcome in balance measures; however the significance level of the correlation differed between tests. Standing one leg eyes closed had strongest correlation to FRAX® (0.610 p = < 0.01) and Five times sit to stand was the only test that did not correlate with FRAX® (0.013). This study showed that there is an association between clinical balance measures and FRAX®. Hence, the use of clinical balance measures and FRAX® in combination, might improve the identification of individuals with high risk of falls and thereby following fractures. Results enable healthcare providers to optimize treatment and prevention of fall-related fractures. The study has been registered in Clinical Trials.gov, registration number NCT00988572 .

  2. Surgical treatment of high-standing greater trochanter.

    PubMed

    Takata, K; Maniwa, S; Ochi, M

    1999-01-01

    Eleven patients with high-standing greater trochanter (13 joints) aged 13-36 years underwent surgery. Distal transfer of the greater trochanter (group T) was performed in 4 patients (5 joints) and lateral displacement osteotomy (group L) in 7 (8 joints). The average follow-up duration was 13.4 years in group T and 5.9 years in group L. Clinical results were evaluated by the hip score according to Merle d'Aubigne. The mean hip score in group T was 13.4 points before operation and 15.4 points after operation, and in group L, 12.8 and 17.4 points, respectively. The postoperative clinical results of group L were significantly better than those of group T (P = 0.0494). In radiological evaluation, although the articulo-trochanteric distance (ATD) increased in both groups in group L it improved remarkably from 9.8 to 24.3, indicating a large descending distance of the greater trochanter. The lever arm ratio (LAR) did not change significantly in group T, but it decreased from 1.97 to 1.60 in group L (P = 0.004). This means that the lever arm of the abductors can certainly be extended by lateral displacement osteotomy. Lateral displacement osteotomy is the most effective procedure for high-standing greater trochanter.

  3. Reliability and prevalence of physical performance examination assessing mobility and balance in older persons in the US: data from the Third National Health and Nutrition Examination Survey.

    PubMed

    Ostchega, Y; Harris, T B; Hirsch, R; Parsons, V L; Kington, R; Katzoff, M

    2000-09-01

    This report provides reliability and prevalence estimates by sex, age, and race/ethnicity of an observed physical performance examination (PPE) assessing mobility and balance. The Third National Health and Nutrition Examination Survey (NHANES III) 1988-1994. A cross-sectional nationally representative survey. All persons aged 60 and older (n = 5,403) who performed the PPE either in the mobile examination center (MEC) or in the home during NHANES III (conducted 1988-1994). The PPE included timed chair stand, full tandem stand, and timed 8-foot walk. Timed chair stand and 8-foot timed walk were reliable measurements (Intraclass Correlations > 0.5). Women were significantly slower (P < .001) than men for both timed chair stands and timed walk. Non-Hispanic white men and women did the maneuvers in significantly less time than non-Hispanic black men and women and Mexican Americans women (P < .001). Lower extremity functions measured by timed chair stand and walk are reliable. Women at every age group were more physically limited than men.

  4. Southern pine beetle in loblolly pine: simulating within stand interactions using the process model SPBLOBTHIN

    Treesearch

    Brian Strom; J. R. Meeker; J. Bishir; James Roberds; X. Wan

    2016-01-01

    Pine stand density is a key determinant of damage resulting from attacks by the southern pine beetle (SPB, Dendroctonus frontalis Zimm.). High-density stands of maturing loblolly pine (Pinus taeda L.) are at high risk for losses to SPB, and reducing stand density is the primary tool available to forest managers for preventing and mitigating damage. Field studies are...

  5. The effect of knee extensor open kinetic chain resistance training in the ACL-injured knee.

    PubMed

    Barcellona, Massimo G; Morrissey, Matthew C; Milligan, Peter; Clinton, Melissa; Amis, Andrew A

    2015-11-01

    To investigate the effect of different loads of knee extensor open kinetic chain resistance training on anterior knee laxity and function in the ACL-injured (ACLI) knee. Fifty-eight ACLI subjects were randomised to one of three (12-week duration) training groups. The STAND group trained according to a standardised rehabilitation protocol. Subjects in the LOW and HIGH group trained as did the STAND group but with the addition of seated knee extensor open kinetic chain resistance training at loads of 2 sets of 20 repetition maximum (RM) and 20 sets of 2RM, respectively. Anterior knee laxity and measurements of physical and subjective function were performed at baseline, 6 and 12 weeks. Thirty-six subjects were tested at both baseline and 12 weeks (STAND n = 13, LOW n = 11, HIGH n = 12). The LOW group demonstrated a reduction in 133 N anterior knee laxity between baseline and 12 weeks testing when compared to the HIGH and the STAND groups (p = 0.009). Specifically, the trained-untrained knee laxity decreased an average of approximately 5 mm in the LOW group while remaining the same in the other two groups. Twelve weeks of knee extensor open kinetic chain resistance training at loads of 2 sets of 20RM led to a reduction in anterior knee laxity in the ACLI knee. This reduction in laxity does not appear to offer any significant short-term functional advantages when compared to a standard rehabilitation protocol. These results indicate that knee laxity can be decreased with resistance training of the thigh muscles. Randomised controlled trial, Level II.

  6. A randomised control trial of the cognitive effects of working in a seated as opposed to a standing position in office workers.

    PubMed

    Russell, Bridget A; Summers, Mathew J; Tranent, Peter J; Palmer, Matthew A; Cooley, P Dean; Pedersen, Scott J

    2016-06-01

    Sedentary behaviour is increasing and has been identified as a potential significant health risk, particularly for desk-based employees. The development of sit-stand workstations in the workplace is one approach to reduce sedentary behaviour. However, there is uncertainty about the effects of sit-stand workstations on cognitive functioning. A sample of 36 university staff participated in a within-subjects randomised control trial examining the effect of sitting vs. standing for one hour per day for five consecutive days on attention, information processing speed, short-term memory, working memory and task efficiency. The results of the study showed no statistically significant difference in cognitive performance or work efficiency between the sitting and standing conditions, with all effect sizes being small to very small (all ds < .2). This result suggests that the use of sit-stand workstations is not associated with a reduction in cognitive performance. Practitioner Summary: Although it has been reported that the use of sit-stand desks may help offset adverse health effects of prolonged sitting, there is scant evidence about changes in productivity. This randomised control study showed that there was no difference between sitting and standing for one hour on cognitive function or task efficiency in university staff.

  7. Urogenital surgery performed with the mare standing.

    PubMed

    Seabaugh, Kathryn A; Schumacher, Jim

    2014-04-01

    Many urogenital procedures of the mare are commonly performed with the mare standing. Ovariectomy via colpotomy was described as early as 1903, and the Caslick vulvoplasty was first described in 1937. As knowledge expands and instruments become more specialized, techniques will improve. With the introduction of laparoscopy, clinicians have not only been able to improve the previously described urogenital procedures but also to devise new procedures. This article describes multiple surgeries of the female urogenital tract, all of which can be performed with the mare standing, and describes a variety of approaches to some portions of the female urogenital tract. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Motherhood, Apple Pie, and Differentiated Instruction

    ERIC Educational Resources Information Center

    VanSciver, James H.

    2005-01-01

    A good Little League baseball coach will analyze a pitcher's performance and develop an individual prescription based on that analysis. Just as all pitchers do not receive the same remedies from high-quality coaches, the author believes, neither should all students. No Child Left Behind (NCLB) stands as the imposing batter to many teachers and…

  9. Treatment for Common Running/Walking Foot Injuries

    ERIC Educational Resources Information Center

    McDaniel, Larry W.; Haar, Calin; Ihlers, Matt; Jackson, Allen; Gaudet, Laura

    2009-01-01

    Whether you are a weekend warrior or a serious athlete, most runners fear the possibility of being injured. For those who are physically active or stand on their feet all day, healthy feet are important Highly conditioned runners spend many hours performing foot maintenance to prevent unnecessary injuries. Some of the common foot injuries are:…

  10. A top-down approach for fabricating free-standing bio-carbon supercapacitor electrodes with a hierarchical structure.

    PubMed

    Li, Yingzhi; Zhang, Qinghua; Zhang, Junxian; Jin, Lei; Zhao, Xin; Xu, Ting

    2015-09-23

    Biomass has delicate hierarchical structures, which inspired us to develop a cost-effective route to prepare electrode materials with rational nanostructures for use in high-performance storage devices. Here, we demonstrate a novel top-down approach for fabricating bio-carbon materials with stable structures and excellent diffusion pathways; this approach is based on carbonization with controlled chemical activation. The developed free-standing bio-carbon electrode exhibits a high specific capacitance of 204 F g(-1) at 1 A g(-1); good rate capability, as indicated by the residual initial capacitance of 85.5% at 10 A g(-1); and a long cycle life. These performance characteristics are attributed to the outstanding hierarchical structures of the electrode material. Appropriate carbonization conditions enable the bio-carbon materials to inherit the inherent hierarchical texture of the original biomass, thereby facilitating effective channels for fast ion transfer. The macropores and mesopores that result from chemical activation significantly increase the specific surface area and also play the role of temporary ion-buffering reservoirs, further shortening the ionic diffusion distance.

  11. 3D free-standing nitrogen-doped reduced graphene oxide aerogel as anode material for sodium ion batteries with enhanced sodium storage.

    PubMed

    Zhang, Jiao; Li, Chuanqi; Peng, Zhikun; Liu, Yushan; Zhang, Jianmin; Liu, Zhongyi; Li, Dan

    2017-07-07

    Sodium ion batteries have drawn extensive attentions for large-scale energy storage to replace lithium ion batteries primarily due to the natural abundance of sodium resource and low cost, but their energy density and electrochemical performance are hindered by the sluggish diffusion kinetics of sodium ion. Herein, free-standing nitrogen-doped graphene aerogel has been fabricated via hydrothermal reaction as the potential anode material for sodium ion batteries. The three dimensional porous network structure of the graphene aerogel provides sufficient interstitial space for sodium ion accommodation, allowing fast and reversible ion intercalation/de-intercalation. The nitrogen doping could introduce defects on the graphene sheets, making the feasible transport of large-sized sodium ion. Benefiting from the effective structure and nitrogen doping, the obtained material demonstrates high reversible capacities, good cycling performance (287.9 mA h g -1 after 200 cycles at a current density of 100 mA g -1 ), especially superior rate capability (151.9 mA h g -1 at a high current density of 5 A g -1 ).

  12. Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation.

    PubMed

    Nataraj, Raviraj; Audu, Musa L; Triolo, Ronald J

    2012-05-06

    The purpose of this study was to determine the comparative effectiveness of feedback control systems for maintaining standing balance based on joint kinematics or total body center of mass (COM) acceleration, and assess their clinical practicality for standing neuroprostheses after spinal cord injury (SCI). In simulation, controller performance was measured according to the upper extremity effort required to stabilize a three-dimensional model of bipedal standing against a variety of postural disturbances. Three cases were investigated: proportional-derivative control based on joint kinematics alone, COM acceleration feedback alone, and combined joint kinematics and COM acceleration feedback. Additionally, pilot data was collected during external perturbations of an individual with SCI standing with functional neuromuscular stimulation (FNS), and the resulting joint kinematics and COM acceleration data was analyzed. Compared to the baseline case of maximal constant muscle excitations, the three control systems reduced the mean upper extremity loading by 51%, 43% and 56%, respectively against external force-pulse perturbations. Controller robustness was defined as the degradation in performance with increasing levels of input errors expected with clinical deployment of sensor-based feedback. At error levels typical for body-mounted inertial sensors, performance degradation due to sensor noise and placement were negligible. However, at typical tracking error levels, performance could degrade as much as 86% for joint kinematics feedback and 35% for COM acceleration feedback. Pilot data indicated that COM acceleration could be estimated with a few well-placed sensors and efficiently captures information related to movement synergies observed during perturbed bipedal standing following SCI. Overall, COM acceleration feedback may be a more feasible solution for control of standing with FNS given its superior robustness and small number of inputs required.

  13. Comparing joint kinematics and center of mass acceleration as feedback for control of standing balance by functional neuromuscular stimulation

    PubMed Central

    2012-01-01

    Background The purpose of this study was to determine the comparative effectiveness of feedback control systems for maintaining standing balance based on joint kinematics or total body center of mass (COM) acceleration, and assess their clinical practicality for standing neuroprostheses after spinal cord injury (SCI). Methods In simulation, controller performance was measured according to the upper extremity effort required to stabilize a three-dimensional model of bipedal standing against a variety of postural disturbances. Three cases were investigated: proportional-derivative control based on joint kinematics alone, COM acceleration feedback alone, and combined joint kinematics and COM acceleration feedback. Additionally, pilot data was collected during external perturbations of an individual with SCI standing with functional neuromuscular stimulation (FNS), and the resulting joint kinematics and COM acceleration data was analyzed. Results Compared to the baseline case of maximal constant muscle excitations, the three control systems reduced the mean upper extremity loading by 51%, 43% and 56%, respectively against external force-pulse perturbations. Controller robustness was defined as the degradation in performance with increasing levels of input errors expected with clinical deployment of sensor-based feedback. At error levels typical for body-mounted inertial sensors, performance degradation due to sensor noise and placement were negligible. However, at typical tracking error levels, performance could degrade as much as 86% for joint kinematics feedback and 35% for COM acceleration feedback. Pilot data indicated that COM acceleration could be estimated with a few well-placed sensors and efficiently captures information related to movement synergies observed during perturbed bipedal standing following SCI. Conclusions Overall, COM acceleration feedback may be a more feasible solution for control of standing with FNS given its superior robustness and small number of inputs required. PMID:22559852

  14. Average Stand Age from Forest Inventory Plots Does Not Describe Historical Fire Regimes in Ponderosa Pine and Mixed-Conifer Forests of Western North America.

    PubMed

    Stevens, Jens T; Safford, Hugh D; North, Malcolm P; Fried, Jeremy S; Gray, Andrew N; Brown, Peter M; Dolanc, Christopher R; Dobrowski, Solomon Z; Falk, Donald A; Farris, Calvin A; Franklin, Jerry F; Fulé, Peter Z; Hagmann, R Keala; Knapp, Eric E; Miller, Jay D; Smith, Douglas F; Swetnam, Thomas W; Taylor, Alan H

    Quantifying historical fire regimes provides important information for managing contemporary forests. Historical fire frequency and severity can be estimated using several methods; each method has strengths and weaknesses and presents challenges for interpretation and verification. Recent efforts to quantify the timing of historical high-severity fire events in forests of western North America have assumed that the "stand age" variable from the US Forest Service Forest Inventory and Analysis (FIA) program reflects the timing of historical high-severity (i.e. stand-replacing) fire in ponderosa pine and mixed-conifer forests. To test this assumption, we re-analyze the dataset used in a previous analysis, and compare information from fire history records with information from co-located FIA plots. We demonstrate that 1) the FIA stand age variable does not reflect the large range of individual tree ages in the FIA plots: older trees comprised more than 10% of pre-stand age basal area in 58% of plots analyzed and more than 30% of pre-stand age basal area in 32% of plots, and 2) recruitment events are not necessarily related to high-severity fire occurrence. Because the FIA stand age variable is estimated from a sample of tree ages within the tree size class containing a plurality of canopy trees in the plot, it does not necessarily include the oldest trees, especially in uneven-aged stands. Thus, the FIA stand age variable does not indicate whether the trees in the predominant size class established in response to severe fire, or established during the absence of fire. FIA stand age was not designed to measure the time since a stand-replacing disturbance. Quantification of historical "mixed-severity" fire regimes must be explicit about the spatial scale of high-severity fire effects, which is not possible using FIA stand age data.

  15. Average Stand Age from Forest Inventory Plots Does Not Describe Historical Fire Regimes in Ponderosa Pine and Mixed-Conifer Forests of Western North America

    PubMed Central

    Stevens, Jens T.; Safford, Hugh D.; North, Malcolm P.; Fried, Jeremy S.; Gray, Andrew N.; Brown, Peter M.; Dolanc, Christopher R.; Dobrowski, Solomon Z.; Falk, Donald A.; Farris, Calvin A.; Franklin, Jerry F.; Fulé, Peter Z.; Hagmann, R. Keala; Knapp, Eric E.; Miller, Jay D.; Smith, Douglas F.; Swetnam, Thomas W.; Taylor, Alan H.

    2016-01-01

    Quantifying historical fire regimes provides important information for managing contemporary forests. Historical fire frequency and severity can be estimated using several methods; each method has strengths and weaknesses and presents challenges for interpretation and verification. Recent efforts to quantify the timing of historical high-severity fire events in forests of western North America have assumed that the “stand age” variable from the US Forest Service Forest Inventory and Analysis (FIA) program reflects the timing of historical high-severity (i.e. stand-replacing) fire in ponderosa pine and mixed-conifer forests. To test this assumption, we re-analyze the dataset used in a previous analysis, and compare information from fire history records with information from co-located FIA plots. We demonstrate that 1) the FIA stand age variable does not reflect the large range of individual tree ages in the FIA plots: older trees comprised more than 10% of pre-stand age basal area in 58% of plots analyzed and more than 30% of pre-stand age basal area in 32% of plots, and 2) recruitment events are not necessarily related to high-severity fire occurrence. Because the FIA stand age variable is estimated from a sample of tree ages within the tree size class containing a plurality of canopy trees in the plot, it does not necessarily include the oldest trees, especially in uneven-aged stands. Thus, the FIA stand age variable does not indicate whether the trees in the predominant size class established in response to severe fire, or established during the absence of fire. FIA stand age was not designed to measure the time since a stand-replacing disturbance. Quantification of historical “mixed-severity” fire regimes must be explicit about the spatial scale of high-severity fire effects, which is not possible using FIA stand age data. PMID:27196621

  16. Performance of a Novel Algorithm Using Automated Digital Microscopy for Diagnosing Tuberculosis.

    PubMed

    Ismail, Nazir A; Omar, Shaheed V; Lewis, James J; Dowdy, David W; Dreyer, Andries W; van der Meulen, Hermina; Nconjana, George; Clark, David A; Churchyard, Gavin J

    2015-06-15

    TBDx automated microscopy is a novel technology that processes digital microscopic images to identify acid-fast bacilli (AFB). Use of TBDx as part of a diagnostic algorithm could improve the diagnosis of tuberculosis (TB), but its performance characteristics have not yet been formally tested. To evaluate the performance of the TBDx automated microscopy system in algorithms for diagnosis of TB. Prospective samples from patients with presumed TB were processed in parallel with conventional smear microscopy, TBDx microscopy, and liquid culture. All TBDx-positive specimens were also tested with the Xpert MTB/RIF (GXP) assay. We evaluated the sensitivity and specificity of two algorithms-(1) TBDx-GXP (TBDx with positive specimens tested by Xpert MTB/RIF) and (2) TBDx alone-against the gold standard liquid media culture. Of 1,210 samples, 1,009 were eligible for evaluation, of which 109 were culture positive for Mycobacterium tuberculosis. The TBDx system identified 70 specimens (68 culture positive) as having 10 or more putative AFB (high positive) and 207 (19 culture positive) as having 1-9 putative AFB (low positive). An algorithm in which "low-positive" results on TBDx were confirmed by GXP had 78% sensitivity (85 of 109) and 99.8% specificity (889 of 900), requiring 21% (207 of 1,009) specimens to be processed by GXP. As a stand-alone test, a "high-positive" result on TBDx had 62% sensitivity and 99.7% specificity. TBDx used in diagnostic algorithms with GXP provided reasonable sensitivity and high specificity for active TB while dramatically reducing the number GXP tests performed. As a stand-alone microscopy system, its performance was equivalent to that of a highly experienced TB microscopist.

  17. Highly stocked coniferous stands on the Olympic Peninsula: chemical composition and implications for harvest strategy.

    Treesearch

    Susan N. Little; Dale R. Waddell

    1987-01-01

    This report presents an assessment of macronutrients and their distribution within highly stocked, stagnant stands of mixed conifers on the Quilcene Ranger District, Olympic National Forest, northwest Washington. These stands consisted of predominantly three species: western hemlock (Tsuga heterophylla (Raf.) Sarg.), coast Douglas-fir (...

  18. Performance comparison investigation on solar photovoltaic-thermoelectric generation and solar photovoltaic-thermoelectric cooling hybrid systems under different conditions

    NASA Astrophysics Data System (ADS)

    Wu, Shuang-Ying; Zhang, Yi-Chen; Xiao, Lan; Shen, Zu-Guo

    2018-07-01

    The performance of solar photovoltaic-thermoelectric generation hybrid system (PV-TGS) and solar photovoltaic-thermoelectric cooling hybrid system (PV-TCS) under different conditions were theoretically analysed and compared. To test the practicality of these two hybrid systems, the performance of stand-alone PV system was also studied. The results show that PV-TGS and PV-TCS in most cases will result in the system with a better performance than stand-alone PV system. The advantage of PV-TGS is emphasised in total output power and conversion efficiency which is even poorer in PV-TCS than that in stand-alone PV system at the ambient wind speed uw being below 3 m/s. However, PV-TCS has obvious advantage on lowering the temperature of PV cell. There is an obvious increase in tendency on the performance of PV-TGS and PV-TCS when the cooling capacity of two hybrid systems varies from around 0.06 to 0.3 W/K. And it is also proved that not just a-Si in PV-TGS can produce a better performance than the stand-alone PV system alone at most cases.

  19. Diamond-Based Supercapacitors: Realization and Properties.

    PubMed

    Gao, Fang; Nebel, Christoph E

    2016-10-26

    In this Spotlight on Applications, we describe our recent progress on the fabrication of surface-enlarged boron-doped polycrystalline diamond electrodes, and evaluate their performance in supercapacitor applications. We begin with a discussion of the fabrication methods of porous diamond materials. The diamond surface enlargement starts with a top-down plasma etching method. Although the extra surface area provided by surface roughening or nanostructuring provides good outcome for sensing applications, a capacitance value <1 mF cm -2 or a surface-enlargement factor <100 fail to meet the requirement of a practical supercapacitor. Driven by the need for large surface areas, we recently focused on the tempated-growth method. We worked on both supported and free-standing porous diamond materials to enhance the areal capacitance to the "mF cm -2 " range. With our newly developed free-standing diamond paper, areal capacitance can be multiplied by stacking multilayers of the electrode material. Finally, considering the fact that there is no real diamond-based supercapacitor device up to now, we fabricated the first prototype pouch-cell device based on the free-standing diamond paper to evaluate its performance. The results reveal that the diamond paper is suitable for operation in high potential windows (up to 2.5 V) in aqueous electrolyte with a capacitance of 0.688 mF cm -2 per layer of paper (or 0.645 F g -1 ). Impedance spectroscopy revealed that the operation frequency of the device exceeds 30 Hz. Because of the large potential window and the ability to work at high frequency, the specific power of the device reached 1 × 10 5 W kg -1 . In the end, we made estimations on the future target performance of diamond supercapacitors based on the existing information.

  20. Evaluation of the Microsoft Kinect as a clinical assessment tool of body sway.

    PubMed

    Yeung, L F; Cheng, Kenneth C; Fong, C H; Lee, Winson C C; Tong, Kai-Yu

    2014-09-01

    Total body center of mass (TBCM) is a useful kinematic measurement of body sway. However, expensive equipment and high technical requirement limit the use of motion capture systems in large-scale clinical settings. Center of pressure (CP) measurement obtained from force plates cannot accurately represent TBCM during large body sway movement. Microsoft Kinect is a rapidly developing, inexpensive, and portable posturographic device, which provides objective and quantitative measurement of TBCM sway. The purpose of this study was to evaluate Kinect as a clinical assessment tool for TBCM sway measurement. The performance of the Kinect system was compared with a Vicon motion capture system and a force plate. Ten healthy male subjects performed four upright quiet standing tasks: (1) eyes open (EOn), (2) eyes closed (ECn), (3) eyes open standing on foam (EOf), and (4) eyes closed standing on foam (ECf). Our results revealed that the Kinect system produced highly correlated measurement of TBCM sway (mean RMSE=4.38 mm; mean CORR=0.94 in Kinect-Vicon comparison), as well as comparable intra-session reliability to Vicon. However, the Kinect device consistently overestimated the 95% CL of sway by about 3mm. This offset could be due to the limited accuracy, resolution, and sensitivity of the Kinect sensors. The Kinect device was more accurate in the medial-lateral than in the anterior-posterior direction, and performed better than the force plate in more challenging balance tasks, such as (ECf) with larger TBCM sway. Overall, Kinect is a cost-effective alternative to a motion capture and force plate system for clinical assessment of TBCM sway. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Behavioral Health and Performance (BHP) Standing Review Panel (SRP) Final Report

    NASA Technical Reports Server (NTRS)

    Suedfeld, Peter; Bootzin, Richard; Harvey, Allison; Leon, Gloria; Musson, David; Oltmanns, Thomas; Paulus, Martin

    2010-01-01

    The first meeting of the Behavioral Health and Performance (BHP) Standing Review Panel (SRP) was held in Houston, TX on November 1-3, 2009. Our task was to assess the Integrated Research Plan (IRP) related to the fields covered in the SRP charge (see section VIII). Having considered and discussed the extensive materials distributed prior to the meeting, and the highly informative briefings by the NASA BHP Human Research Program (HRP) personnel during the site visit, the SRP agreed that the IRP is comprehensive and was developed carefully. Question and answer periods with the presenters were particularly productive and helpful to the SRP. The presenters' willingness to share information and positive responses to the SRP's suggestions were greatly appreciated. Although the IRP and related documents are impressive, the SRP does have a number of recommendations regarding both the overall plan and its component parts.

  2. Long-term stand growth of interior ponderosa pine stands in response to structural modifications and burning treatments in northeastern California

    Treesearch

    Justin S. Crotteau; Martin W. Ritchie

    2014-01-01

    The Blacks Mountain Experimental Research Project created two distinct overstory structural classes (high structural diversity [HiD]; low-structural diversity [LoD]) across 12 stands and subsequently burned half of each stand. We analyzed stand-level growth 10 years after treatment and then modeled individual tree growth to forecast stand-level growth 10–20 years after...

  3. Developing silvicultural systems based on partial cutting in western hemlock–Sitka spruce stands of southeast Alaska.

    Treesearch

    Robert L. Deal; J.C. Tappeiner; Paul E. Hennon

    2002-01-01

    The effects of partial cutting on species composition, stand structure and growth, tree size distribution, and tree disease and mortality were evaluated on 73 plots in 18 stands that were harvested 12–96 years ago in southeast Alaska. Partially-cut stands had diverse and highly complex stand structures similar to uncut stands. Sitka spruce was maintained in mixed...

  4. Office-Cycling: A Promising Way to Raise Pain Thresholds and Increase Metabolism with Minimal Compromising of Work Performance

    PubMed Central

    Nyberg, André; Hedlund, Mattias; Häger, Charlotte K.; McDonough, Suzanne; Björklund, Martin

    2018-01-01

    Aim Establishing the effects of low intensity cycling (LC), moderate intensity cycling (MC), and standing at a simulated office workstation on pain modulation, work performance, and metabolic expenditure. Methods 36 healthy adults (21 females), mean age 26.8 (SD 7.6) years, partook in this randomized 3 × 3 crossover trial with 75 minutes of LC on 20% of maximum aerobic power (MAP) output, 30 minutes of MC on 50% of MAP, and standing 30 minutes with 48-hour wash-out periods. Outcome measures were pain modulation (pressure pain threshold (PPT) and thermal pain threshold)), work performance (transcription, mouse pointing, and cognitive performance), and metabolic expenditure. Results PPTs increased in all conditions. PPT trapezius showed the highest increase after LC, 39.3 kilopascals (kPa) (15.6; 78.6), compared to MC, 17.0 kPa (2.8; 49.9), and standing, 16.8 kPa (−5.6; 39.4), p = 0.015. Transcription was reduced during LC and MC. Mouse pointing precision was best during standing and worst and slowest during MC. Cognitive performance did not differ between conditions. Metabolic expenditure rates were 1.4 (1.3; 1.7), 3.3 (2.3; 3.7), and 7.5 (5.8; 8.7) kcal/minute during standing, LC, and MC, respectively (p < 0.001). Conclusions LC seems to be the preferred option; it raised PPTs, more than doubled metabolic expenditure, whilst minimally influencing work performance. PMID:29607323

  5. Leaf δ18O of remaining trees is affected by thinning intensity in a semiarid pine forest.

    PubMed

    Moreno-Gutiérrez, Cristina; Barberá, Gonzalo G; Nicolás, Emilio; DE Luis, Martín; Castillo, Víctor M; Martínez-Fernández, Faustino; Querejeta, José I

    2011-06-01

    Silvicultural thinning usually improves the water status of remaining trees in water-limited forests. We evaluated the usefulness of a dual stable isotope approach (δ¹³C, δ¹⁸O) for comparing the physiological performance of remaining trees between forest stands subjected to two different thinning intensities (moderate versus heavy) in a 60-year-old Pinus halepensis Mill. plantation in semiarid southeastern Spain. We measured bulk leaf δ¹³C and δ¹⁸O, foliar elemental concentrations, stem water content, stem water δ¹⁸O (δ¹⁸O(stem water)), tree ring widths and leaf gas exchange rates to assess the influence of forest stand density on tree performance. Remaining trees in low-density stands (heavily thinned) showed lower leaf δ¹⁸O, and higher stomatal conductance (g(s)), photosynthetic rate and radial growth than those in moderate-density stands (moderately thinned). By contrast, leaf δ¹³C, intrinsic water-use efficiency, foliar elemental concentrations and δ¹⁸O(stem water) were unaffected by stand density. Lower foliar δ¹⁸O in heavily thinned stands reflected higher g(s) of remaining trees due to decreased inter-tree competition for water, whereas higher photosynthetic rate was largely attributable to reduced stomatal limitation to CO₂ uptake. The dual isotope approach provided insight into the early (12 months) effects of stand density manipulation on the physiological performance of remaining trees. © 2011 Blackwell Publishing Ltd.

  6. A Study of relationship between frailty and physical performance in elderly women

    PubMed Central

    Jeoung, Bog Ja; Lee, Yang Chool

    2015-01-01

    Frailty is a disorder of multiple inter-related physiological systems. It is unclear whether the level of physical performance factors can serve as markers of frailty and a sign. The purpose of this study was to examine the relationship between frailty and physical performance in elderly women. One hundred fourteen elderly women participated in this study, their aged was from 65 to 80. We were measured 6-min walk test, grip-strength, 30-sec arm curl test, 30-sec chair stand test, 8 foot Up- and Go, Back scratch, chair sit and reach, unipedal stance, BMI, and the frailty with questionnaire. The collected data were analyzed by descriptive statistics, frequencies, correlation analysis, ANOVA, and simple liner regression using the IBM 21. SPSS program. In results, statistic tests showed that there were significant differences between frailty and 6-min walk test, 30-sec arm curl test, 30-sec chair stand test, grip-strength, Back scratch, and BMI. However, we did not find significant differences between frailty and 8 foot Up- and Go, unipedal stance. When the subjects were divided into five groups according to physical performance level, subjects with high 6-min walk, 30-sec arm curl test, chair sit and reach test, and high grip strength had low score frailty. Physical performance factors were strongly associated with decreased frailty, suggesting that physical performance improvements play an important role in preventing or reducing the frailty. PMID:26331137

  7. Conservation value of low-productivity forests measured as the amount and diversity of dead wood and saproxylic beetles.

    PubMed

    Hämäläinen, Aino; Strengbom, Joachim; Ranius, Thomas

    2018-06-01

    In many managed landscapes, low-productivity land comprises most of the remaining relatively untouched areas, and is often over-represented within protected areas. The relationship between the productivity and conservational value of a site is poorly known; however, it has been hypothesized that biodiversity increases with productivity due to higher resource abundance or heterogeneity, and that the species communities of low-productivity land are a nested subset of communities from more productive land. We tested these hypotheses for dead-wood-dependent beetles by comparing their species richness and composition, as well as the amount and diversity of dead wood, between low-productivity (potential forest growth <1 m 3 ·ha -1 ·yr -1 ) and high-productivity Scots pine-dominated stands in Sweden. We included four stand types: stands situated on (1) thin soils and (2) mires (both low-productivity), (3) managed stands, and (4) unmanaged stands set aside for conservation purposes (both high-productivity). Beetle species richness and number of red-listed species were highest in the high-productivity set-asides. Species richness was positively correlated with the volume and diversity of dead wood, but volume appeared to be a better predictor than diversity for the higher species richness in set-asides. Beetle species composition was similar among stand types, and the assemblages in low-productivity stands were largely subsets of those in high-productivity set-asides. However, 11% of all species and 40% of red-listed species only occurred in high-productivity stands, while no species were unique to low-productivity stands. We conclude that low-productivity forests are less valuable for conservation than high-productivity forest land. Given the generally similar species composition among stand types, a comparable conservational effect could be obtained by setting aside a larger area of low-productivity forest in comparison to the high-productivity. In terms of dead wood volumes, 1.8-3.6 ha of low-productivity forest has the same value as 1 ha of unmanaged high-productivity forest. This figure can be used to estimate the conservation value of low-productivity forests; however, as high-productivity forests harbored some unique species, they are not completely exchangeable. © 2018 The Authors. Ecological Applications published by Wiley Periodicals, Inc. on behalf of Ecological Society of America.

  8. Distribution of standing-wave errors in real-ear sound-level measurements.

    PubMed

    Richmond, Susan A; Kopun, Judy G; Neely, Stephen T; Tan, Hongyang; Gorga, Michael P

    2011-05-01

    Standing waves can cause measurement errors when sound-pressure level (SPL) measurements are performed in a closed ear canal, e.g., during probe-microphone system calibration for distortion-product otoacoustic emission (DPOAE) testing. Alternative calibration methods, such as forward-pressure level (FPL), minimize the influence of standing waves by calculating the forward-going sound waves separate from the reflections that cause errors. Previous research compared test performance (Burke et al., 2010) and threshold prediction (Rogers et al., 2010) using SPL and multiple FPL calibration conditions, and surprisingly found no significant improvements when using FPL relative to SPL, except at 8 kHz. The present study examined the calibration data collected by Burke et al. and Rogers et al. from 155 human subjects in order to describe the frequency location and magnitude of standing-wave pressure minima to see if these errors might explain trends in test performance. Results indicate that while individual results varied widely, pressure variability was larger around 4 kHz and smaller at 8 kHz, consistent with the dimensions of the adult ear canal. The present data suggest that standing-wave errors are not responsible for the historically poor (8 kHz) or good (4 kHz) performance of DPOAE measures at specific test frequencies.

  9. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladder June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  10. A-3 Test Stand

    NASA Image and Video Library

    2012-06-08

    A tethered Stennis Space Center employee climbs an A-3 Test Stand ladded June 8, 2012, against the backdrop of the A-2 and B-1/B-2 stands. The new A-3 Test Stand will enable simulated high-altitude testing of next-generation rocket engines.

  11. Ten-Year Performance of Eastern White Pine - under a Crop Tree Release Regime on an Outwash Site

    Treesearch

    Kenneth M. Desmarais; William B. Leak; William B. Leak

    2005-01-01

    A young stand of eastern white pine aged 38-40 years received a crop tree release cutting reducing stocking to 100 tree/ac. This stocking level reflects the number of sterms per acre that would be contained in a well stocked mature stand at final harvest (20-in. quadratic mean stand diameter). The stand then was monitored for growth and value change. Stems that grew...

  12. Positive edge effects on forest-interior cryptogams in clear-cuts.

    PubMed

    Caruso, Alexandro; Rudolphi, Jörgen; Rydin, Håkan

    2011-01-01

    Biological edge effects are often assessed in high quality focal habitats that are negatively influenced by human-modified low quality matrix habitats. A deeper understanding of the possibilities for positive edge effects in matrix habitats bordering focal habitats (e.g. spillover effects) is, however, essential for enhancing landscape-level resilience to human alterations. We surveyed epixylic (dead wood inhabiting) forest-interior cryptogams (lichens, bryophytes, and fungi) associated with mature old-growth forests in 30 young managed Swedish boreal forest stands bordering a mature forest of high conservation value. In each young stand we registered species occurrences on coarse dead wood in transects 0-50 m from the border between stand types. We quantified the effect of distance from the mature forest on the occurrence of forest-interior species in the young stands, while accounting for local environment and propagule sources. For comparison we also surveyed epixylic open-habitat (associated with open forests) and generalist cryptogams. Species composition of epixylic cryptogams in young stands differed with distance from the mature forest: the frequency of occurrence of forest-interior species decreased with increasing distance whereas it increased for open-habitat species. Generalists were unaffected by distance. Epixylic, boreal forest-interior cryptogams do occur in matrix habitats such as clear-cuts. In addition, they are associated with the matrix edge because of a favourable microclimate closer to the mature forest on southern matrix edges. Retention and creation of dead wood in clear-cuts along the edges to focal habitats is a feasible way to enhance the long-term persistence of epixylic habitat specialists in fragmented landscapes. The proposed management measures should be performed in the whole stand as it matures, since microclimatic edge effects diminish as the matrix habitat matures. We argue that management that aims to increase habitat quality in matrix habitats bordering focal habitats should increase the probability of long-term persistence of habitat specialists.

  13. Positive Edge Effects on Forest-Interior Cryptogams in Clear-Cuts

    PubMed Central

    Caruso, Alexandro; Rudolphi, Jörgen; Rydin, Håkan

    2011-01-01

    Biological edge effects are often assessed in high quality focal habitats that are negatively influenced by human-modified low quality matrix habitats. A deeper understanding of the possibilities for positive edge effects in matrix habitats bordering focal habitats (e.g. spillover effects) is, however, essential for enhancing landscape-level resilience to human alterations. We surveyed epixylic (dead wood inhabiting) forest-interior cryptogams (lichens, bryophytes, and fungi) associated with mature old-growth forests in 30 young managed Swedish boreal forest stands bordering a mature forest of high conservation value. In each young stand we registered species occurrences on coarse dead wood in transects 0–50 m from the border between stand types. We quantified the effect of distance from the mature forest on the occurrence of forest-interior species in the young stands, while accounting for local environment and propagule sources. For comparison we also surveyed epixylic open-habitat (associated with open forests) and generalist cryptogams. Species composition of epixylic cryptogams in young stands differed with distance from the mature forest: the frequency of occurrence of forest-interior species decreased with increasing distance whereas it increased for open-habitat species. Generalists were unaffected by distance. Epixylic, boreal forest-interior cryptogams do occur in matrix habitats such as clear-cuts. In addition, they are associated with the matrix edge because of a favourable microclimate closer to the mature forest on southern matrix edges. Retention and creation of dead wood in clear-cuts along the edges to focal habitats is a feasible way to enhance the long-term persistence of epixylic habitat specialists in fragmented landscapes. The proposed management measures should be performed in the whole stand as it matures, since microclimatic edge effects diminish as the matrix habitat matures. We argue that management that aims to increase habitat quality in matrix habitats bordering focal habitats should increase the probability of long-term persistence of habitat specialists. PMID:22114728

  14. Space Shuttle Projects

    NASA Image and Video Library

    1991-07-01

    This photograph shows the Solid Propellant Test Article (SPTA) test stand with the Modified Nasa Motor (M-NASA) test article at the Marshall Space Flight Center (MSFC). The SPTA test stand, 12-feet wide by 12-feet long by 24-feet high, was built in 1989 to provide comparative performance data on nozzle and case insulation material and to verify thermostructural analysis models. A modified NASA 48-inch solid motor (M-NASA motor) with a 12-foot blast tube and 10-inch throat makes up the SPTA. The M-NASA motor is being used to evaluate solid rocket motor internal non-asbestos insulation materials, nozzle designs, materials, and new inspection techniques. New internal motor case instrumentation techniques are also being evaluated.

  15. A Novel Type of Battery-Supercapacitor Hybrid Device with Highly Switchable Dual Performances Based on a Carbon Skeleton/Mg2Ni Free-Standing Hydrogen Storage Electrode.

    PubMed

    Li, Na; Du, Yi; Feng, Qing-Ping; Huang, Gui-Wen; Xiao, Hong-Mei; Fu, Shao-Yun

    2017-12-27

    The sharp proliferation of high power electronics and electrical vehicles has promoted growing demands for power sources with both high energy and power densities. Under these circumstances, battery-supercapacitor hybrid devices are attracting considerable attention as they combine the advantages of both batteries and supercapacitors. Here, a novel type of hybrid device based on a carbon skeleton/Mg 2 Ni free-standing electrode without the traditional nickel foam current collector is reported, which has been designed and fabricated through a dispersing-freeze-drying method by employing reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) as a hybrid skeleton. As a result, the Mg 2 Ni alloy is able to deliver a high discharge capacity of 644 mAh g -1 and, more importantly, a high cycling stability with a retention of over 78% after 50 charge/discharge cycles have been achieved, which exceeds almost all the results ever reported on the Mg 2 Ni alloy. Simultaneously, the electrode could also exhibit excellent supercapacitor performances including high specific capacities (296 F g -1 ) and outstanding cycling stability (100% retention after 100 cycles). Moreover, the hybrid device can switch between battery and supercapacitor modes immediately as needed during application. These features make the C skeleton/alloy electrode a highly promising candidate for battery-supercapacitor hybrid devices with high power/energy density and favorable cycling stability.

  16. Testing the generality of above-ground biomass allometry across plant functional types at the continent scale.

    PubMed

    Paul, Keryn I; Roxburgh, Stephen H; Chave, Jerome; England, Jacqueline R; Zerihun, Ayalsew; Specht, Alison; Lewis, Tom; Bennett, Lauren T; Baker, Thomas G; Adams, Mark A; Huxtable, Dan; Montagu, Kelvin D; Falster, Daniel S; Feller, Mike; Sochacki, Stan; Ritson, Peter; Bastin, Gary; Bartle, John; Wildy, Dan; Hobbs, Trevor; Larmour, John; Waterworth, Rob; Stewart, Hugh T L; Jonson, Justin; Forrester, David I; Applegate, Grahame; Mendham, Daniel; Bradford, Matt; O'Grady, Anthony; Green, Daryl; Sudmeyer, Rob; Rance, Stan J; Turner, John; Barton, Craig; Wenk, Elizabeth H; Grove, Tim; Attiwill, Peter M; Pinkard, Elizabeth; Butler, Don; Brooksbank, Kim; Spencer, Beren; Snowdon, Peter; O'Brien, Nick; Battaglia, Michael; Cameron, David M; Hamilton, Steve; McAuthur, Geoff; Sinclair, Jenny

    2016-06-01

    Accurate ground-based estimation of the carbon stored in terrestrial ecosystems is critical to quantifying the global carbon budget. Allometric models provide cost-effective methods for biomass prediction. But do such models vary with ecoregion or plant functional type? We compiled 15 054 measurements of individual tree or shrub biomass from across Australia to examine the generality of allometric models for above-ground biomass prediction. This provided a robust case study because Australia includes ecoregions ranging from arid shrublands to tropical rainforests, and has a rich history of biomass research, particularly in planted forests. Regardless of ecoregion, for five broad categories of plant functional type (shrubs; multistemmed trees; trees of the genus Eucalyptus and closely related genera; other trees of high wood density; and other trees of low wood density), relationships between biomass and stem diameter were generic. Simple power-law models explained 84-95% of the variation in biomass, with little improvement in model performance when other plant variables (height, bole wood density), or site characteristics (climate, age, management) were included. Predictions of stand-based biomass from allometric models of varying levels of generalization (species-specific, plant functional type) were validated using whole-plot harvest data from 17 contrasting stands (range: 9-356 Mg ha(-1) ). Losses in efficiency of prediction were <1% if generalized models were used in place of species-specific models. Furthermore, application of generalized multispecies models did not introduce significant bias in biomass prediction in 92% of the 53 species tested. Further, overall efficiency of stand-level biomass prediction was 99%, with a mean absolute prediction error of only 13%. Hence, for cost-effective prediction of biomass across a wide range of stands, we recommend use of generic allometric models based on plant functional types. Development of new species-specific models is only warranted when gains in accuracy of stand-based predictions are relatively high (e.g. high-value monocultures). © 2015 John Wiley & Sons Ltd.

  17. Two-Dimensional Standing Wave Total Internal Reflection Fluorescence Microscopy: Superresolution Imaging of Single Molecular and Biological Specimens

    PubMed Central

    Chung, Euiheon; Kim, Daekeun; Cui, Yan; Kim, Yang-Hyo; So, Peter T. C.

    2007-01-01

    The development of high resolution, high speed imaging techniques allows the study of dynamical processes in biological systems. Lateral resolution improvement of up to a factor of 2 has been achieved using structured illumination. In a total internal reflection fluorescence microscope, an evanescence excitation field is formed as light is total internally reflected at an interface between a high and a low index medium. The <100 nm penetration depth of evanescence field ensures a thin excitation region resulting in low background fluorescence. We present even higher resolution wide-field biological imaging by use of standing wave total internal reflection fluorescence (SW-TIRF). Evanescent standing wave (SW) illumination is used to generate a sinusoidal high spatial frequency fringe pattern on specimen for lateral resolution enhancement. To prevent thermal drift of the SW, novel detection and estimation of the SW phase with real-time feedback control is devised for the stabilization and control of the fringe phase. SW-TIRF is a wide-field superresolution technique with resolution better than a fifth of emission wavelength or ∼100 nm lateral resolution. We demonstrate the performance of the SW-TIRF microscopy using one- and two-directional SW illumination with a biological sample of cellular actin cytoskeleton of mouse fibroblast cells as well as single semiconductor nanocrystal molecules. The results confirm the superior resolution of SW-TIRF in addition to the merit of a high signal/background ratio from TIRF microscopy. PMID:17483188

  18. Free-standing and flexible graphene papers as disposable non-enzymatic electrochemical sensors.

    PubMed

    Zhang, Minwei; Halder, Arnab; Hou, Chengyi; Ulstrup, Jens; Chi, Qijin

    2016-06-01

    We have explored AuNPs (13 nm) both as a catalyst and as a core for synthesizing water-dispersible and highly stable core-shell structural gold@Prussian blue (Au@PB) nanoparticles (NPs). Systematic characterization by transmission electron microscopy (TEM) and X-ray photoelectron spectroscopy (XPS) disclosed AuNPs coated uniformly by a 5 nm thick PB layer. Au@PB NPs were attached to single-layer graphene oxide (GO) to form Au@PB decorated GO sheets. The resulting hybrid material was filtered layer-by-layer into flexible and free-standing GO paper, which was further converted into conductive reduced GO (RGO)/Au@PB paper via hydrazine vapour reduction. High-resolution TEM images suggested that RGO papers are multiply sandwich-like structures functionalized with core-shell NPs. Resulting sandwich functionalized graphene papers have high conductivity, sufficient flexibility, and robust mechanical strength, which can be cut into free-standing electrodes. Such electrodes, used as non-enzymatic electrochemical sensors, were tested systematically for electrocatalytic sensing of hydrogen peroxide. The high performance was indicated by some of the key parameters, for example the linear H2O2 concentration response range (1-30 μM), the detection limit (100 nM), and the high amperometric sensitivity (5 A cm(-2) M(-1)). With the advantages of low cost and scalable production capacity, such graphene supported functional papers are of particular interest in the use as flexible disposable sensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Adaptations to Speed Endurance Training in Highly Trained Soccer Players.

    PubMed

    Nyberg, Michael; Fiorenza, Matteo; Lund, Anders; Christensen, Magnus; Rømer, Tue; Piil, Peter; Hostrup, Morten; Christensen, Peter M; Holbek, Simon; Ravnholt, Thomas; Gunnarsson, Thomas P; Bangsbo, Jens

    2016-07-01

    The present study examined whether a period of additional speed endurance training would improve intense intermittent exercise performance in highly trained soccer players during the season and whether the training changed aerobic metabolism and the level of oxidative enzymes in type I and type II muscle fibers. During the last 9 wk of the season, 13 semiprofessional soccer players performed additional speed endurance training sessions consisting of two to three sets of 8-10 repetitions of 30-m sprints with 10 s of passive recovery (SET). Before and after SET, subjects completed a double-step exercise protocol that included transitions from standing to moderate-intensity running (~75% HRmax), followed by transitions from moderate- to high-intensity running (~90% HRmax) in which pulmonary oxygen uptake (V˙O2) was determined. In addition, the yo-yo intermittent recovery test level 1 was performed, and a muscle biopsy was obtained at rest. The yo-yo intermittent recovery test level 1 performance was 11.6% ± 6.4% (mean ± SD) better (2803 ± 330 vs 3127 ± 383 m, P < 0.05) after SET compared with before SET. In the transition from standing to moderate-intensity running, phase II pulmonary V˙O2 kinetics was 11.4% ± 16.5% faster (P < 0.05), and the running economy at this intensity was 2.3% ± 3.0% better (P < 0.05). These improvements were apparent despite the content of muscle proteins regulating oxidative metabolism (3-hydroxyacyl CoA dehydrogenase, COX IV, and OXPHOS), and capillarization was reduced (P < 0.05). The content of 3-hydroxyacyl CoA dehydrogenase and citrate synthase in type I and type II fibers did not change. In highly trained soccer players, additional speed endurance training is associated with an improved ability to perform repeated high-intensity work. To what extent the training-induced changes in V˙O2 kinetics and mechanical efficiency in type I fibers caused the improvement in performance warrants further investigation.

  20. Relationship between built environment attributes and physical function in Japanese community-dwelling older adults.

    PubMed

    Soma, Yuki; Tsunoda, Kenji; Kitano, Naruki; Jindo, Takashi; Tsuji, Taishi; Saghazadeh, Mahshid; Okura, Tomohiro

    2017-03-01

    To explore the relationships between the built environment and older adults' physical function. The present cross-sectional study carried out in 2010-2012 used data drawn from 509 community-dwelling older adults aged 65-86 years living in Kasama City, a Japanese rural region. We evaluated physical function with the following performance tests: grip strength, sit-to-stand, timed up & go and walking speed. Using geographic information systems, we measured population density and the number of destinations related to daily life, community centers, medical facilities and recreational facilities within participants' neighborhoods. After adjusting for potential confounders, we found lower population density was related to poor performance of sit-to-stand and walking speed in both sexes, and grip strength in women (trend P < 0.05). A lower number of daily life-related destinations was related to poor performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. Similarly, the number of community centers was related to walking speed in both sexes. The number of medical and recreational facilities was also related to some physical performance in both sexes. A lower land use mix score, calculated by principal component analysis, was related to lower performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. The present study suggests that, although there are some sex differences, low population density, land use mix, and fewer daily life-related destinations, community centers, medical facilities and recreational facilities are negative determinants of physical function. Geriatr Gerontol Int 2017; 17: 382-390. © 2016 Japan Geriatrics Society.

  1. Measurement-to-measurement blood pressure variability is related to cognitive performance: the Maine Syracuse study.

    PubMed

    Crichton, Georgina E; Elias, Merrill F; Dore, Gregory A; Torres, Rachael V; Robbins, Michael A

    2014-11-01

    The objective was to investigate the association between variability in blood pressure (BP) and cognitive function for sitting, standing, and reclining BP values and variability derived from all 15 measures. In previous studies, only sitting BP values have been examined, and only a few cognitive measures have been used. A secondary objective was to examine associations between BP variability and cognitive performance in hypertensive individuals stratified by treatment success. Cross-sectional analyses were performed on 972 participants of the Maine Syracuse Study for whom 15 serial BP clinic measures (5 sitting, 5 recumbent, and 5 standing) were obtained before testing of cognitive performance. Using all 15 measures, higher variability in systolic and diastolic BP was associated with poorer performance on multiple measures of cognitive performance, independent of demographic factors, cardiovascular risk factors, and pulse pressure. When sitting, reclining, and standing systolic BP values were compared, only variability in standing BP was related to measures of cognitive performance. However, for diastolic BP, variability in all 3 positions was related to cognitive performance. Mean BP values were weaker predictors of cognition. Furthermore, higher overall variability in both systolic and diastolic BP was associated with poorer cognitive performance in unsuccessfully treated hypertensive individuals (with BP ≥140/90 mm Hg), but these associations were not evident in those with controlled hypertension. © 2014 American Heart Association, Inc.

  2. Standing on a declining surface reduces transient prolonged standing induced low back pain development.

    PubMed

    Gallagher, Kaitlin M; Callaghan, Jack P

    2016-09-01

    While alternating standing position on a sloped surface has proven successful at reducing low back pain during standing, the purpose of this study was to evaluate standing solely on a declining surface to isolate the influence of the postural change. Seventeen participants performed two 75-min prolonged standing occupational simulations- level ground and declining surface. Fifty-three percent of participants (9/17) were categorized as pain developers during the level ground standing condition. For these same pain developers, their average maximum pain scores were 58% lower during sloped standing. All participants showed greater hip flexion, trunk-to-thigh angle flexion, and posterior translation of the trunk center of gravity when standing on the sloped surface. These postural changes could cause the muscles crossing the hip posteriorly to increase passive stiffness and assist with stabilizing the pelvis. This study stresses the importance of hip kinematics, not just lumbar spine posture, in reducing prolonged standing induced low back pain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Series asymmetric supercapacitors based on free-standing inner-connection electrodes for high energy density and high output voltage.

    PubMed

    Tao, Jiayou; Liu, Nishuang; Rao, Jiangyu; Ding, Longwei; Al Bahrani, Majid Raissan; Li, Luying; Su, Jun; Gao, Yihua

    2014-12-21

    Asymmetric supercapacitors (ASCs) based on free-standing membranes with high energy density and high output voltage are reported. MnO(2) nanowire/carbon nanotube (CNT) composites and MoO(3) nanobelt/CNT composites are selected as the anode and the cathode materials of the devices, respectively. The ASC has a high volumetric capacitance of 50.2 F cm(-3) at a scan rate of 2 mV s(-1) and a high operation voltage window of 2.0 V. Especially, after a middle layer with an inner-connection structure was inserted between the anode and the cathode, the output voltage of the whole device can achieve 4.0 V. The full cell of series ASCs (SASC) with an inner-connection middle layer has a high energy density of 28.6 mW h cm(-3) at a power density of 261.4 mW cm(-3), and exhibits excellent cycling performance of 99.6% capacitance retention over 10,000 cycles. This strategy of designing the hybridized structure for SASCs provides a promising route for next-generation SCs with high energy density and high output voltage.

  4. Stand, Harvest, and Equipment Interactions in Simulated Harvesting Prescriptions

    Treesearch

    Jingxin Wang; W. Dale Greene; Bryce J. Stokes

    1998-01-01

    We evaluated potential interactions of stand type, harvesting method, and equipment in an experiment using interactive simulation. We examined three felling methods (chain saw, feller-buncher, harvester) and two extraction methods (grapple skidder and forwarder) performing clearcuts, sheltenvood cuts, and single-tree selection cuts in both an uneven-aged natural stand...

  5. Stocking, growth, and yield of oak stands

    Treesearch

    Samuel F. Gingrich

    1971-01-01

    An appraisal of stocking in even-aged upland oak stands is a prerequisite for determining the cultural needs of a given stand. Most oak stands have sufficient stocking to utilize the site, but are deficient in high-quality trees. Thinning such stands offers a good opportunity to upgrade the relative quality of the growing stock and enhance the growth and yield...

  6. Deer Browse Production of Oak Stands in Central Lower Michigan

    Treesearch

    Leslie W. Gysel; Forest Stearns

    1968-01-01

    The extensive oak forests of Lower Michigan provide essential habitat for whitetailed deer and other wildlife. Clearcutting these stands results in high browse production (500-1000 lbs./acre) compared to uncut stands (200-500 lbs./acre). Most browse in uncut stands is under 18 inches tall, whereas much of that in open stands is above snowline and thus available in...

  7. Flexible integration of free-standing nanowires into silicon photonics.

    PubMed

    Chen, Bigeng; Wu, Hao; Xin, Chenguang; Dai, Daoxin; Tong, Limin

    2017-06-14

    Silicon photonics has been developed successfully with a top-down fabrication technique to enable large-scale photonic integrated circuits with high reproducibility, but is limited intrinsically by the material capability for active or nonlinear applications. On the other hand, free-standing nanowires synthesized via a bottom-up growth present great material diversity and structural uniformity, but precisely assembling free-standing nanowires for on-demand photonic functionality remains a great challenge. Here we report hybrid integration of free-standing nanowires into silicon photonics with high flexibility by coupling free-standing nanowires onto target silicon waveguides that are simultaneously used for precise positioning. Coupling efficiency between a free-standing nanowire and a silicon waveguide is up to ~97% in the telecommunication band. A hybrid nonlinear-free-standing nanowires-silicon waveguides Mach-Zehnder interferometer and a racetrack resonator for significantly enhanced optical modulation are experimentally demonstrated, as well as hybrid active-free-standing nanowires-silicon waveguides circuits for light generation. These results suggest an alternative approach to flexible multifunctional on-chip nanophotonic devices.Precisely assembling free-standing nanowires for on-demand photonic functionality remains a challenge. Here, Chen et al. integrate free-standing nanowires into silicon waveguides and show all-optical modulation and light generation on silicon photonic chips.

  8. Mapping spatial distribution of forest age in China

    NASA Astrophysics Data System (ADS)

    Zhang, Yuan; Yao, Yitong; Wang, Xuhui; Liu, Yongwen; Piao, Shilong

    2017-03-01

    Forest stand age is a meaningful metric, which reflects the past disturbance legacy, provides guidelines for forest management practices, and is an important factor in qualifying forest carbon cycles and carbon sequestration potential. Reliable large-scale forest stand age information with high spatial resolutions, however, is difficult to obtain. In this study, we developed a top-down method to downscale the provincial statistics of national forest inventory data into 1 km stand age map using climate data and light detection and ranging-derived forest height. We find that the distribution of forest stand age in China is highly heterogeneous across the country, with a mean value of 42.6 years old. The relatively young stand age for Chinese forests is mostly due to the large proportion of newly planted forests (0-40 years old), which are more prevailing in south China. Older forests (stand age > 60 years old) are more frequently found in east Qinghai-Tibetan Plateau and the central mountain areas of west and northeast China, where human activities are less intensive. Among the 15 forest types, forests dominated by species of Taxodiaceae, with the exception of Cunninghamia lanceolata stands, have the oldest mean stand age (136 years), whereas Pinus massoniana forests are the youngest (18 years). We further identified uncertainties associated with our forest age map, which are high in west and northeast China. Our work documents the distribution of forest stand age in China at a high resolution which is useful for carbon cycle modeling and the sustainable use of China's forest resources.

  9. A Proposal for a High-Voltage Transmission Line Directional Coupler

    DOE PAGES

    Olsen, R. G.; Li, Zhi

    2017-02-01

    Directional couplers are devices generally used in high frequency transmission lines and waveguides that respond to forward and reverse traveling waves separately. Hence they can be used to either measure standing wave ratio in the steady state or to determine the direction of a propagating transient wave. Here, a design is proposed for a directional coupler to be used on multimode high voltage transmission lines. Its performance is analyzed and several suggestions are made for improving its design.

  10. The ambiguity of standing in standing devices: a qualitative interview study concerning children and parents experiences of the use of standing devices.

    PubMed

    Nordström, Birgitta; Näslund, Annika; Ekenberg, Lilly; Zingmark, Karin

    2014-10-01

    The aim of this study was to describe children's and parents' experiences of the significance of standing in a standing device. Individual interviews were performed with six children/teenagers (aged 7-19 years) and 14 parents. The interviews were transcribed and analyzed using a qualitative content analysis. The analysis resulted in the major theme, the duality of uprightness and the related themes: (1) the instrumental dimension of standing; (2) the social dimension of standing; and (3) the ambivalent dimension of standing. Each of the themes comprised several subthemes. There is an inherent duality related to the use of a standing device. Standing in a standing device was seen as a treatment of body structures and functions, as well as a possible source of pain. Standing was considered to influence freedom in activities and participation both positively and negatively. The parents experienced that standing influenced other peoples' views of their child, while the children experienced standing as a way to extend the body and as something that gave them benefits in some activities. Physiotherapists working with children should take into account both the social and physical dimensions of using a standing device and consider both the child's and the parents' views.

  11. High amplitude nonlinear acoustic wave driven flow fields in cylindrical and conical resonators.

    PubMed

    Antao, Dion Savio; Farouk, Bakhtier

    2013-08-01

    A high fidelity computational fluid dynamic model is used to simulate the flow, pressure, and density fields generated in a cylindrical and a conical resonator by a vibrating end wall/piston producing high-amplitude standing waves. The waves in the conical resonator are found to be shock-less and can generate peak acoustic overpressures that exceed the initial undisturbed pressure by two to three times. A cylindrical (consonant) acoustic resonator has limitations to the output response observed at one end when the opposite end is acoustically excited. In the conical geometry (dissonant acoustic resonator) the linear acoustic input is converted to high energy un-shocked nonlinear acoustic output. The model is validated using past numerical results of standing waves in cylindrical resonators. The nonlinear nature of the harmonic response in the conical resonator system is further investigated for two different working fluids (carbon dioxide and argon) operating at various values of piston amplitude. The high amplitude nonlinear oscillations observed in the conical resonator can potentially enhance the performance of pulse tube thermoacoustic refrigerators and these conical resonators can be used as efficient mixers.

  12. Transition play in team performance of volleyball: a log-linear analysis.

    PubMed

    Eom, H J; Schutz, R W

    1992-09-01

    The purpose of this study was to develop and test a method to analyze and evaluate sequential skill performances in a team sport. An on-line computerized system was developed to record and summarize the sequential skill performances in volleyball. Seventy-two sample games from the third Federation of International Volleyball Cup men's competition were videotaped and grouped into two categories according to the final team standing and game outcome. Log-linear procedures were used to investigate the nature and degree of the relationship in the first-order (pass-to-set, set-to-spike) and second-order (pass-to-spike) transition plays. Results showed that there was a significant dependency in both the first-order and second-order transition plays, indicating that the outcome of a skill performance is highly influenced by the quality of a preceding skill performance. In addition, the pattern of the transition plays was stable and consistent, regardless of the classification status: Game Outcome, Team Standing, or Transition Process. The methodology and subsequent results provide valuable aids for a thorough understanding of the characteristics of transition plays in volleyball. In addition, the concept of sequential performance analysis may serve as an example for sport scientists in investigating probabilistic patterns of motor performance.

  13. An unsupervised two-stage clustering approach for forest structure classification based on X-band InSAR data - A case study in complex temperate forest stands

    NASA Astrophysics Data System (ADS)

    Abdullahi, Sahra; Schardt, Mathias; Pretzsch, Hans

    2017-05-01

    Forest structure at stand level plays a key role for sustainable forest management, since the biodiversity, productivity, growth and stability of the forest can be positively influenced by managing its structural diversity. In contrast to field-based measurements, remote sensing techniques offer a cost-efficient opportunity to collect area-wide information about forest stand structure with high spatial and temporal resolution. Especially Interferometric Synthetic Aperture Radar (InSAR), which facilitates worldwide acquisition of 3d information independent from weather conditions and illumination, is convenient to capture forest stand structure. This study purposes an unsupervised two-stage clustering approach for forest structure classification based on height information derived from interferometric X-band SAR data which was performed in complex temperate forest stands of Traunstein forest (South Germany). In particular, a four dimensional input data set composed of first-order height statistics was non-linearly projected on a two-dimensional Self-Organizing Map, spatially ordered according to similarity (based on the Euclidean distance) in the first stage and classified using the k-means algorithm in the second stage. The study demonstrated that X-band InSAR data exhibits considerable capabilities for forest structure classification. Moreover, the unsupervised classification approach achieved meaningful and reasonable results by means of comparison to aerial imagery and LiDAR data.

  14. Estimating merchantable volumes of second growth Douglas-fir stands from total cubic volume and associated stand characteristics.

    Treesearch

    Richard L. Williamson; Robert O. Curtis

    1980-01-01

    Equations are given for estimating merchantable volumes of second-growth Douglas-fir stands to specified breast-high and top-diameter limits, in cubic feet or board feet, from total volume in cubic feet and certain associated stand characteristics.

  15. High rate capacitive performance of single-walled carbon nanotube aerogels

    DOE PAGES

    Van Aken, Katherine L.; Pérez, Carlos R.; Oh, Youngseok; ...

    2015-05-30

    Single-walled carbon nanotube (SWCNT) aerogels produced by critical-point-drying of wet-gel precursors exhibit unique properties, such as high surface-area-to-volume and strength-to-weight ratios. They are free-standing, are binder-free, and can be scaled to thicknesses of more than 1 mm. In this paper, we examine the electric double layer capacitive behavior of these materials using a common room temperature ionic liquid electrolyte, 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMI-TFSI). Electrochemical performance is assessed through galvanostatic cycling, cyclic voltammetry and impedance spectroscopy. Results indicate stable capacitive performance over 10,000 cycles as well as an impressive performance at high charge and discharge rates, due to accessible pore networks andmore » enhanced electronic and ionic conductivities of SWCNT aerogels. Finally, these materials can find applications in mechanically compressible and flexible supercapacitor devices with high power requirements.« less

  16. Inverted Pendulum Standing Apparatus for Investigating Closed-Loop Control of Ankle Joint Muscle Contractions during Functional Electrical Stimulation.

    PubMed

    Tan, John F; Masani, Kei; Vette, Albert H; Zariffa, José; Robinson, Mark; Lynch, Cheryl; Popovic, Milos R

    2014-01-01

    The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pendulum, whose angular position is determined by the subject's ankle joint angle as controlled by the FES system while having the subject's body fixed in a standing frame. This approach provides a setup that is safe, prevents falling, and enables a research and design team to rigorously test various closed-loop controlled FES systems applied to the ankle joints. To demonstrate the feasibility of using the IPSA, we conducted a case series that employed the device for studying FES closed-loop controllers for regulating ankle joint kinematics during standing. The utilized FES system stimulated, in able-bodied volunteers, the plantarflexors as they prevent toppling during standing. Four different conditions were compared, and we were able to show unique performance of each condition using the IPSA. We concluded that the IPSA is a useful tool for developing and testing closed-loop controlled FES systems for regulating ankle joint position during standing.

  17. Inverted Pendulum Standing Apparatus for Investigating Closed-Loop Control of Ankle Joint Muscle Contractions during Functional Electrical Stimulation

    PubMed Central

    Tan, John F.; Masani, Kei; Vette, Albert H.; Zariffa, José; Robinson, Mark; Lynch, Cheryl; Popovic, Milos R.

    2014-01-01

    The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pendulum, whose angular position is determined by the subject's ankle joint angle as controlled by the FES system while having the subject's body fixed in a standing frame. This approach provides a setup that is safe, prevents falling, and enables a research and design team to rigorously test various closed-loop controlled FES systems applied to the ankle joints. To demonstrate the feasibility of using the IPSA, we conducted a case series that employed the device for studying FES closed-loop controllers for regulating ankle joint kinematics during standing. The utilized FES system stimulated, in able-bodied volunteers, the plantarflexors as they prevent toppling during standing. Four different conditions were compared, and we were able to show unique performance of each condition using the IPSA. We concluded that the IPSA is a useful tool for developing and testing closed-loop controlled FES systems for regulating ankle joint position during standing. PMID:27350992

  18. Series asymmetric supercapacitors based on free-standing inner-connection electrodes for high energy density and high output voltage

    NASA Astrophysics Data System (ADS)

    Tao, Jiayou; Liu, Nishuang; Rao, Jiangyu; Ding, Longwei; Al Bahrani, Majid Raissan; Li, Luying; Su, Jun; Gao, Yihua

    2014-11-01

    Asymmetric supercapacitors (ASCs) based on free-standing membranes with high energy density and high output voltage are reported. MnO2 nanowire/carbon nanotube (CNT) composites and MoO3 nanobelt/CNT composites are selected as the anode and the cathode materials of the devices, respectively. The ASC has a high volumetric capacitance of 50.2 F cm-3 at a scan rate of 2 mV s-1 and a high operation voltage window of 2.0 V. Especially, after a middle layer with an inner-connection structure was inserted between the anode and the cathode, the output voltage of the whole device can achieve 4.0 V. The full cell of series ASCs (SASC) with an inner-connection middle layer has a high energy density of 28.6 mW h cm-3 at a power density of 261.4 mW cm-3, and exhibits excellent cycling performance of 99.6% capacitance retention over 10 000 cycles. This strategy of designing the hybridized structure for SASCs provides a promising route for next-generation SCs with high energy density and high output voltage.Asymmetric supercapacitors (ASCs) based on free-standing membranes with high energy density and high output voltage are reported. MnO2 nanowire/carbon nanotube (CNT) composites and MoO3 nanobelt/CNT composites are selected as the anode and the cathode materials of the devices, respectively. The ASC has a high volumetric capacitance of 50.2 F cm-3 at a scan rate of 2 mV s-1 and a high operation voltage window of 2.0 V. Especially, after a middle layer with an inner-connection structure was inserted between the anode and the cathode, the output voltage of the whole device can achieve 4.0 V. The full cell of series ASCs (SASC) with an inner-connection middle layer has a high energy density of 28.6 mW h cm-3 at a power density of 261.4 mW cm-3, and exhibits excellent cycling performance of 99.6% capacitance retention over 10 000 cycles. This strategy of designing the hybridized structure for SASCs provides a promising route for next-generation SCs with high energy density and high output voltage. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr04819a

  19. Biomass yielding potential of naturally regenerated Prosopis juliflora tree stands at three varied ecosystems in southern districts of Tamil Nadu, India.

    PubMed

    Saraswathi, K; Chandrasekaran, S

    2016-05-01

    Fuel energy demand is of great concern in recent times due to the depletion of fossil fuel resources. Biomass serves as widely available primary renewable energy source. Hence, a study was performed to assess the above-ground biomass yielding capability of fuel wood tree Prosopis juliflora in three varied ecosystems viz., coastal, fallow land and riparian ecosystems in southern districts of Tamil Nadu. The results showed that the biomass production potential and above-ground net primary productivity of P. juliflora depend on the age of the tree stands and the nature of ecosystem. A higher biomass yield was observed for P. juliflora trees with 5 to 10 years old when compared to less than 5 years of their age. Among the three ecosystems, the maximum biomass production was recorded in riparian ecosystem. The stands with less than 5-year-old P. juliflora trees gave 1.40 t/ha, and 5- to 10-year-old tree stands produced 27.69 t/ha in riparian ecosystem. Above-ground net primary productivity of both the age groups was high in fallow land ecosystem. In riparian ecosystem, the wood showed high density and low sulphur content than the other two ecosystems. Hence, P. juliflora biomass can serve as an environmentally and economically feasible fuel as well as their utilization proffers an effective means to control its invasiveness.

  20. Toward high performance nanoscale optoelectronic devices: super solar energy harvesting in single standing core-shell nanowire.

    PubMed

    Zhou, Jian; Wu, Yonggang; Xia, Zihuan; Qin, Xuefei; Zhang, Zongyi

    2017-11-27

    Single nanowire solar cells show great promise for next-generation photovoltaics and for powering nanoscale devices. Here, we present a detailed study of light absorption in a single standing semiconductor-dielectric core-shell nanowire (CSNW). We find that the CSNW structure can not only concentrate the incident light into the structure, but also confine most of the concentrated light to the semiconductor core region, which boosts remarkably the light absorption cross-section of the semiconductor core. The CSNW can support multiple higher-order HE modes, as well as Fabry-Pérot (F-P) resonance, compared to the bare nanowire (BNW). Overlapping of the adjacent higher-order HE modes results in broadband light absorption enhancement in the solar radiation spectrum. Results based on detailed balance analysis demonstrate that the super light concentration of the single CSNW gives rise to higher short-circuit current and open-circuit voltage, and thus higher apparent power conversion efficiency (3644.2%), which goes far beyond that of the BNW and the Shockley-Queisser limit that restricts the performance of a planar counterparts. Our study shows that the single CSNW can be a promising platform for construction of high performance nanoscale photodetectors, nanoelectronic power sources, super miniature cells, and diverse integrated nanosystems.

  1. 3D Interconnected V6O13 Nanosheets Grown on Carbonized Textile via a Seed-Assisted Hydrothermal Process as High-Performance Flexible Cathodes for Lithium-Ion Batteries

    NASA Astrophysics Data System (ADS)

    Xu, Shixing; Cen, Dingcheng; Gao, Peibo; Tang, Huang; Bao, Zhihao

    2018-03-01

    Three-dimensional (3D) free-standing nanostructured materials have been proven to be one of the most promising electrodes for energy storage due to their enhanced electrochemical performance. And they are also widely studied for the wearable energy storage systems. In this work, interconnected V6O13 nanosheets were grown on the flexible carbonized textile (c-textile) via a seed-assisted hydrothermal method to form a 3D free-standing electrode for lithium-ion batteries (LIBs). The electrode exhibited a specific capacity of 170 mA h g-1 at a specific current of 300 mA g-1. With carbon nanotube (CNT) coating, its specific capacities further increased 12-40% at the various current rates. It could retain a reversible capacity of 130 mA h g-1, 74% of the initial capacity after 300 cycles at the specific current of 300 mA g-1. It outperformed most of the mixed-valence vanadium oxides. The improved electrochemical performance was ascribed to the synergistic effect of the 3D nanostructure of V6O13 for feasible Li+ diffusion and transport and highly conductive hierarchical conductive network formed by CNT and carbon fiber in c-textile.

  2. Harvesting small trees for bio-energy

    Treesearch

    John Klepac; Robert Rummer; Jason Thompson

    2011-01-01

    A conventional whole-tree logging operation consisting of 4-wheeled and 3-wheeled saw-head feller-bunchers, two grapple skidders and a chipper that produces dirty chips was monitored across several stands and machine performance evaluated. Stands were inventoried to determine density, volume, and basal area per acre and will be used to relate machine performance to...

  3. Pulsed Electric Propulsion Thrust Stand Calibration Method

    NASA Technical Reports Server (NTRS)

    Wong, Andrea R.; Polzin, Kurt A.; Pearson, J. Boise

    2011-01-01

    The evaluation of the performance of any propulsion device requires the accurate measurement of thrust. While chemical rocket thrust is typically measured using a load cell, the low thrust levels associated with electric propulsion (EP) systems necessitate the use of much more sensitive measurement techniques. The design and development of electric propulsion thrust stands that employ a conventional hanging pendulum arm connected to a balance mechanism consisting of a secondary arm and variable linkage have been reported in recent publications by Polzin et al. These works focused on performing steady-state thrust measurements and employed a static analysis of the thrust stand response. In the present work, we present a calibration method and data that will permit pulsed thrust measurements using the Variable Amplitude Hanging Pendulum with Extended Range (VAHPER) thrust stand. Pulsed thrust measurements are challenging in general because the pulsed thrust (impulse bit) occurs over a short timescale (typically 1 micros to 1 millisecond) and cannot be resolved directly. Consequently, the imparted impulse bit must be inferred through observation of the change in thrust stand motion effected by the pulse. Pulsed thrust measurements have typically only consisted of single-shot operation. In the present work, we discuss repetition-rate pulsed thruster operation and describe a method to perform these measurements. The thrust stand response can be modeled as a spring-mass-damper system with a repetitive delta forcing function to represent the impulsive action of the thruster.

  4. Implementing Athletic Trainers for the Management of Cheerleading Injuries

    ERIC Educational Resources Information Center

    Nakajima, Mikiko; Valdez, Josepha M.

    2013-01-01

    Cheerleading used to be about standing on the sidelines waving pom-poms. Now, cheerleaders are thrown 10 feet in the air and perform high-level gymnastics skills. For this reason, cheerleading has become the leading cause of catastrophic sport injuries in the United States. Football, which is one of the most dangerous sports, has abundant access…

  5. Kinetic potential influences visual and remote haptic perception of affordances for standing on an inclined surface.

    PubMed

    Malek, Eric A; Wagman, Jeffrey B

    2008-01-01

    The ability of a perceiver-actor to perform a particular behaviour depends on their ability to generate and control the muscular forces required to perform that behaviour. If an intended behaviour is to be successful, perception must be relative to this ability. We investigated whether perceiver-actors were sensitive to how changes in their mass distribution influenced their ability to stand on an inclined surface. Participants reported whether they would be able to stand on an inclined surface while wearing a weighted backpack on their back, while wearing a weighted backpack on their front, and while not wearing a weighted backpack. In addition, participants performed this task by either viewing the surface or exploring it with a hand-held rod (while blindfolded). The results showed that perception of affordances for standing on the inclined surface depended on how the backpack influenced the ability of the participant to stand on the surface. Specifically, perceptual boundaries occurred at steeper inclinations when participants wore the backpack on their front than when they wore it on their back. Moreover, this pattern occurred regardless of the perceptual modality by which the participants explored the inclined surface.

  6. First-year results of a prescribed burn in a high-elevation red oak stand

    Treesearch

    Peter Bates; Dean Simon

    2009-01-01

    In March 2007, a prescribed burn was conducted on approximately 70 acres in a high-elevation red oak stand located on the Cold Mountain Game Land in western North Carolina. This burn was the first in a series of treatments designed to increase oak and hickory regeneration in this stand.

  7. Silvicultural aspects intermediate cuttings

    Treesearch

    Kenneth L. Carvell

    1971-01-01

    Correct timing of the first thinning in mixed oak stands depends largely on the composition and condition of the stands and on available markets for small wood products. Delaying first thinnings in high-quality seedling-origin stands until a long, straight, clear bole has developed is of primary importance in assuring high quality of the final crop trees. However, many...

  8. Novel PMN-PT free standing film for high frequency (80MHz) intravascular ultrasonic imaging

    PubMed Central

    Li, Xiang; Zhou, Qifa; Shung, K. Kirk; Shih, Wei-Heng; Shih, Wan Y.

    2011-01-01

    [Pb(Mg1/3Nb2/3)O3]0.63[PbTiO3]0.37 (PMN-PT) free standing film of comparable piezoelectric property to bulk PMN-PT with a thickness of 33 μm has been fabricated using a modified precursor coating approach. At 1 KHz, the dielectric constant and loss were 4,160 and 0.0291, respectively. The remnant polarization and coercive field were 28 μC/cm2 and 18.43 kV/cm. The electromechanical coupling coefficient kt was measured to be 0.55, which was close to that of bulk PMN-PT single crystal material. A high frequency (80 MHz) miniature ultrasonic transducer with high sensitivity was fabricated from this film. In vitro imaging of a rabbit aorta was performed to demonstrate the application of this material to intravascular ultrasound imaging at 80 MHz. Compared to a 35 MHz ultrasonic image, the 80 MHz image showed superior resolution and contrast. PMID:22083761

  9. Apparatus and methods for real-time detection of explosives devices

    DOEpatents

    Blackburn, Brandon W [Idaho Falls, ID; Hunt, Alan W [Pocatello, ID; Chichester, David L [Idaho Falls, ID

    2014-01-07

    The present disclosure relates, according to some embodiments, to apparatus, devices, systems, and/or methods for real-time detection of a concealed or camouflaged explosive device (e.g., EFPs and IEDs) from a safe stand-off distance. Apparatus, system and/or methods of the disclosure may also be operable to identify and/or spatially locate and/or detect an explosive device. An apparatus or system may comprise an x-ray generator that generates high-energy x-rays and/or electrons operable to contact and activate a metal comprised in an explosive device from a stand-off distance; and a detector operable to detect activation of the metal. Identifying an explosive device may comprise detecting characteristic radiation signatures emitted by metals specific to an EFP, an IED or a landmine. Apparatus and systems of the disclosure may be mounted on vehicles and methods of the disclosure may be performed while moving in the vehicle and from a safe stand-off distance.

  10. Multi-dimensional construction of a novel active yolk@conductive shell nanofiber web as a self-standing anode for high-performance lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Chen, Luyi; Liang, Yeru; Fu, Ruowen; Wu, Dingcai

    2015-11-01

    A novel active yolk@conductive shell nanofiber web with a unique synergistic advantage of various hierarchical nanodimensional objects including the 0D monodisperse SiO2 yolks, the 1D continuous carbon shell and the 3D interconnected non-woven fabric web has been developed by an innovative multi-dimensional construction method, and thus demonstrates excellent electrochemical properties as a self-standing LIB anode.A novel active yolk@conductive shell nanofiber web with a unique synergistic advantage of various hierarchical nanodimensional objects including the 0D monodisperse SiO2 yolks, the 1D continuous carbon shell and the 3D interconnected non-woven fabric web has been developed by an innovative multi-dimensional construction method, and thus demonstrates excellent electrochemical properties as a self-standing LIB anode. Electronic supplementary information (ESI) available: Experimental details and additional information about material characterization. See DOI: 10.1039/c5nr06531c

  11. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-06-22

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test themore » digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.« less

  12. Forging of metallic nano-objects for the fabrication of submicron-size components

    NASA Astrophysics Data System (ADS)

    Rösler, J.; Mukherji, D.; Schock, K.; Kleindiek, S.

    2007-03-01

    In recent years, nanoscale fabrication has developed considerably, but the fabrication of free-standing nanosize components is still a great challenge. The fabrication of metallic nanocomponents utilizing three basic steps is demonstrated here. First, metallic alloys are used as factories to produce a metallic raw stock of nano-objects/nanoparticles in large numbers. These objects are then isolated from the powder containing thousands of such objects inside a scanning electron microscope using manipulators, and placed on a micro-anvil or a die. Finally, the shape of the individual nano-object is changed by nanoforging using a microhammer. In this way free-standing, high-strength, metallic nano-objects may be shaped into components with dimensions in the 100 nm range. By assembling such nanocomponents, high-performance microsystems can be fabricated, which are truly in the micrometre scale (the size ratio of a system to its component is typically 10:1).

  13. Physical performance tests after stroke: reliability and validity.

    PubMed

    Maeda, A; Yuasa, T; Nakamura, K; Higuchi, S; Motohashi, Y

    2000-01-01

    To evaluate the reliability and validity of the modified physical performance tests for stroke survivors who live in a community. The subjects included 40 stroke survivors and 40 apparently healthy independent elderly persons. The physical performance tests for the stroke survivors comprised two physical capacity evaluation tasks that represented physical abilities necessary to perform the main activities of daily living, e.g., standing-up ability (time needed to stand up from bed rest) and walking ability (time needed to walk 10 m). Regarding the reliability of tests, significant correlations were confirmed between test and retest of physical performance tests with both short and long intervals in individuals after stroke. Regarding the validity of tests, the authors studied the significant correlations between the maximum isometric strength of the quardriceps muscle and the time needed to walk 10 m, centimeters reached while sitting and reaching, and the time needed to stand up from bed rest. The authors confirmed that there were significant correlations between the instrumental activity of daily living and the time needed to stand up from bed rest, along with the time needed to walk 10 m for the stroke survivors. These physical performance tests are useful guides for evaluating a level of activity of daily living and physical frailty of stroke survivors living in a community.

  14. Functional Performance As a Predictor of Injurious Falls Among Older Adults

    PubMed Central

    Ward, Rachel E.; Leveille, Suzanne G.; Beauchamp, Marla K.; Travison, Thomas; Alexander, Neil; Jette, Alan M.; Bean, Jonathan F.

    2014-01-01

    OBJECTIVES Guidelines for falls risk assessment include functional performance although evidence supporting specific tests for predicting injurious falls is lacking. We investigated whether a performance battery/its components aid in predicting injurious falls. DESIGN Longitudinal analysis; prospective cohort study. SETTING Clinical site. PARTICIPANTS 755 Boston area community-dwelling adults (mean ± SD: age=78.1 ± 5.4, 64.1% women, 77.6% white). MEASUREMENTS Baseline functional performance was determined by the SPPB measuring balance, gait speed, and 5 repeated chair stands. Fall history (past year) and efficacy in performing 10 daily activities without falling were assessed. Falls were assessed using a daily calendar over 4 years. Injurious falls were defined by fractures, sprains, dislocations, pulled or torn muscles, ligaments, or tendons or by seeking medical attention. RESULTS Poorest chair stand performance was associated with greater hazard of injurious falls compared to all other groups (HR [95% CI]: 1.96 [1.18–3.26], 1.65 [1.07–2.55], and 1.60 [1.03–2.48] for ≥16.7s vs. 13.7–16.6s, 11.2–13.6s, and <11.2s). SPPB did not predict injurious falls. Fall history predicted injurious falls (HR [95% CI]: 1.82 [1.39–2.39]); falls efficacy did not. Fall history and a slow chair stand (<16.7s) compounded 2-year cumulative incidence of an injurious fall (0.46, [0.34–0.58]) compared to positive fall history (0.29, [0.25–0.34]) or a slow chair stand alone (0.21, [0.13–0.30]). CONCLUSION An easily administered chair stand test may be sufficient for evaluating performance as part of a risk stratification strategy for injurious falls. PMID:25688606

  15. Assessment of Site and Stand Disturbance From Cut-To-Length Harvesting

    Treesearch

    Clyde G. Vidrine; Conelius deHoop; Bobby L. Lanford

    1999-01-01

    Assessment of stand and soil disturbance resulting from cut-to-length (CTL) winter season harvest demonstrations performed on a 12-year-old pine plantation first thinning. 23-year-old second thinning, and a mixed pine/hardwood natural stand clearcut harvest is reported. The harvests were perfomed on Martin Timber Company lands in central Louisiana, during February...

  16. Evaluating growth performance of young stands

    Treesearch

    A. L. Roe; R. E. Benson

    1966-01-01

    A simple procedure for evaluating the diameter growth of young stands in relation to potential growth is described. A comparison technique is developed which contrasts relative diameter of crop trees to the relative diameter growth of the last decade to show the condition and trend of growth in the stand. The method is objective, easy to use, and has several...

  17. Predictive Cutoff Values of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for Disability Incidence in Older People Dwelling in the Community.

    PubMed

    Makizako, Hyuma; Shimada, Hiroyuki; Doi, Takehiko; Tsutsumimoto, Kota; Nakakubo, Sho; Hotta, Ryo; Suzuki, Takao

    2017-04-01

    Lower extremity functioning is important for maintaining activity in elderly people. Optimal cutoff points for standard measurements of lower extremity functioning would help identify elderly people who are not disabled but have a high risk of developing disability. The purposes of this study were: (1) to determine the optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability and (2) to examine the impact of poor performance on both tests on the prediction of the risk of disability in elderly people dwelling in the community. This was a prospective cohort study. A population of 4,335 elderly people dwelling in the community (mean age = 71.7 years; 51.6% women) participated in baseline assessments. Participants were monitored for 2 years for the development of disability. During the 2-year follow-up period, 161 participants (3.7%) developed disability. The optimal cutoff points of the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test for predicting the development of disability were greater than or equal to 10 seconds and greater than or equal to 9 seconds, respectively. Participants with poor performance on the Five-Times Sit-to-Stand Test (hazard ratio = 1.88; 95% CI = 1.11-3.20), the Timed "Up & Go" Test (hazard ratio = 2.24; 95% CI = 1.42-3.53), or both tests (hazard ratio = 2.78; 95% CI = 1.78-4.33) at the baseline assessment had a significantly higher risk of developing disability than participants who had better lower extremity functioning. All participants had good initial functioning and participated in assessments on their own. Causes of disability were not assessed. Assessments of lower extremity functioning with the Five-Times Sit-to-Stand Test and the Timed "Up & Go" Test, especially poor performance on both tests, were good predictors of future disability in elderly people dwelling in the community. © 2017 American Physical Therapy Association

  18. Space Shuttle Projects

    NASA Image and Video Library

    1978-09-01

    Workmen in the Dynamic Test Stand lowered the nose cone into place to complete stacking of the left side of the solid rocket booster (SRB) in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). The SRB would be attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT was to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB'S to which the ET was attached.

  19. Foraging and nesting habitat of breeding male northern goshawks in the laurentian mixed forest province, Minnesota

    USGS Publications Warehouse

    Boal, C.W.; Andersen, D.E.; Kennedy, P.L.

    2005-01-01

    We used radiotelemetry to examine foraging habitat preferences of 17 breeding, male northern goshawks (Accipiter gentilis) in Minnesota from 1998-2000. We assessed habitat preference using radio relocation points and 50-m radius buffers of radio relocation points. Our data suggested that foraging male goshawks used early-successional upland conifer stands (???25 yrs old), early-successional upland deciduous stands (???50 yrs old), late-successional upland conifer stands (???50 yrs old), and late-successional upland deciduous stands (???50 yrs old) more frequently than expected based on the abundance of these vegetation types in the landscape. The 2 most available stand types, early-successional upland deciduous (<25 yrs old) and all ages of late-successional lowland conifer stands, were used less than expected by foraging goshawks. Late-successional lowland deciduous stands (???50 yrs old) were used in proportion to availability. Although analysis of relocation points suggested early-successional upland deciduous stands (25-49 yrs old) and late-successional upland conifer stands (???50 yrs old) were used in proportion to availability, analysis of buffers around relocation points indicated that these stand types were also used more than expected by foraging goshawks. Regardless of vegetation community type, stands used by goshawks were structurally similar with high canopy and understory stem densities, high canopy closure, substantial shrub cover, and large amounts of woody debris. Nest stands consisted of taller and larger diameter canopy trees and fewer understory trees than foraging stands, but stands were otherwise similar in structural features, suggesting goshawks used similar stands for nesting and foraging but that they tended to select the most mature stands for nesting. A commonality among nesting and foraging stands was the presence of open spaces between the canopy and understory foliage, and between understory and shrub layer foliage. In our study area, these spaces may have served as relatively unobstructed flight paths where foraging and nesting stands possessed stem densities at the upper end of that reported for goshawk habitat.

  20. Patterns of NPP, GPP, respiration, and NEP during boreal forest succession

    USGS Publications Warehouse

    Goulden, M.L.; Mcmillan, A.M.S.; Winston, G.C.; Rocha, A.V.; Manies, K.L.; Harden, J.W.; Bond-Lamberty, B. P.

    2011-01-01

    We combined year-round eddy covariance with biometry and biomass harvests along a chronosequence of boreal forest stands that were 1, 6, 15, 23, 40, 74, and 154 years old to understand how ecosystem production and carbon stocks change during recovery from stand-replacing crown fire. Live biomass (Clive) was low in the 1 and 6 year old stands, and increased following a logistic pattern to high levels in the 74 and 154year old stands. Carbon stocks in the forest floor (Cforest floor) and coarse woody debris (CCWD) were comparatively high in the 1year old stand, reduced in the 6 through 40year old stands, and highest in the 74 and 154year old stands. Total net primary production (TNPP) was reduced in the 1 and 6year old stands, highest in the 23 through 74year old stands and somewhat reduced in the 154year old stand. The NPP decline at the 154year old stand was related to increased autotrophic respiration rather than decreased gross primary production (GPP). Net ecosystem production (NEP), calculated by integrated eddy covariance, indicated the 1 and 6 year old stands were losing carbon, the 15year old stand was gaining a small amount of carbon, the 23 and 74year old stands were gaining considerable carbon, and the 40 and 154year old stands were gaining modest amounts of carbon. The recovery from fire was rapid; a linear fit through the NEP observations at the 6 and 15year old stands indicated the transition from carbon source to sink occurred within 11-12 years. The NEP decline at the 154year old stand appears related to increased losses from Clive by tree mortality and possibly from Cforest floor by decomposition. Our findings support the idea that NPP, carbon production efficiency (NPP/GPP), NEP, and carbon storage efficiency (NEP/TNPP) all decrease in old boreal stands. ?? 2010 Blackwell Publishing Ltd.

  1. Late quaternary lake level changes of Taro Co and neighbouring lakes, southwestern Tibetan Plateau, based on OSL dating and ostracod analysis

    NASA Astrophysics Data System (ADS)

    Alivernini, Mauro; Lai, Zhongping; Frenzel, Peter; Fürstenberg, Sascha; Wang, Junbo; Guo, Yun; Peng, Ping; Haberzettl, Torsten; Börner, Nicole; Mischke, Steffen

    2018-07-01

    The Late Quaternary lake history of Taro Co and three neighbouring lakes was investigated to reconstruct local hydrological conditions and the regional moisture availability. Ostracod-based water depth and habitat reconstructions combined with OSL and radiocarbon dating are performed to better understand the Taro Co lake system evolution during the Late Quaternary. A high-stand is observed at 36.1 ka before present which represents the highest lake level since then related to a wet stage and resulting in a merging of Taro Co and its neighbouring lakes Zabuye and Lagkor Co this time. The lake level then decreased and reached its minimum around 30 ka. After c. 20 ka, the lake rose above the present day level. A minor low-stand, with colder and drier conditions, is documented at 12.5 cal. ka BP. Taro Co Zabuye and Lagkor Co formed one large lake with a corresponding high-stand during the early Holocene (11.2-9.7 cal. ka BP). After this Holocene lake level maximum, all three lakes shrank, probably related to drier conditions, and Lagkor Co became separated from the Taro Co-Zabuye system at c.7 ka. Subsequently, the lake levels decreased further about 30 m and Taro Co began to separate from Zabuye Lake at around 3.5 ka. The accelerating lake-level decrease of Taro Co was interrupted by a short-term lake level rise after 2 ka BP, probably related to minor variations of the monsoonal components. A last minor high-stand occurred at about 0.8 ka before today and subsequently the lake level of Taro Co registers a slight increase in recent years.

  2. Climate change induced effects on the predisposition of forests of the water protection zone Wildalpen to disturbances by bark beetles

    NASA Astrophysics Data System (ADS)

    Baier, P.; Pennerstorfer, J.; Schopf, A.

    2012-04-01

    The provision of drinking water of high quality is a precious service of forests. Large-scale disturbances like forest fires, wind throws, pest outbreaks and subsequent clear cutting may lead to changes in hydrology (runoff as well as percolation). Furthermore, water quality can be negatively influenced by increased erosion, increased decomposition of litter and humus and leaching of nitrate. Large-scale epidemics of forest pests may induce forest decline at landscape scale with subsequent long-lasting negative effects on water quality. The European spruce bark beetle, Ips typographus (L.), is one of the most significant sources of mortality in mature spruce forest ecosystems in Eurasia. The objective of this study was to apply a complex predisposition assessment system for hazard rating and for the evaluation of climate change impacts for the water protection forests of the City of Vienna in Wildalpen. The following steps have been done to adapt/apply the bark beetle phenology model and the hazard rating system: -application, adaptation and validation of the bark beetle phenology model PHENIPS concerning start of dispersion, brood initiation, duration of development, beginning of sister broods, voltinism and hibernation - spatial/temporal modelling of the phenology and voltinism of I. typographus using past, present as well as projected climate data - application and validation of the stand- and site related long-term predisposition assessment system using forest stand/site data, annual damage reports and outputs of phenology modelling as data input - mapping of endangered areas and assessment of future susceptibility to infestations by I. typographus and other disturbing agents based on climate scenarios using GIS. The assessment of site- and stand-related predisposition revealed that the forest stands in Wildalpen are highly susceptible to bark beetle infestation. More than 65% of the stands were assigned to the predisposition classes high/very high. Only 10% of the stands showed a low stand-related predisposition to bark beetle infestations. This high susceptibility to bark beetle damage is related to the dominance of even-aged, spruce-dominated mature stands. The projected change in voltinism of I. typographus will further increase total predisposition of the stands to bark beetle infestations. Mapping the projected predisposition of present-day forest stands at the end of the century clearly indicated that stands with high/very high susceptibility to bark beetle infestation form large continuous areas, a pre-requisite for extended epidemics of I. typographus.

  3. Developing Novel Machine Learning Algorithms to Improve Sedentary Assessment for Youth Health Enhancement.

    PubMed

    Golla, Gowtham Kumar; Carlson, Jordan A; Huan, Jun; Kerr, Jacqueline; Mitchell, Tarrah; Borner, Kelsey

    2016-10-01

    Sedentary behavior of youth is an important determinant of health. However, better measures are needed to improve understanding of this relationship and the mechanisms at play, as well as to evaluate health promotion interventions. Wearable accelerometers are considered as the standard for assessing physical activity in research, but do not perform well for assessing posture (i.e., sitting vs. standing), a critical component of sedentary behavior. The machine learning algorithms that we propose for assessing sedentary behavior will allow us to re-examine existing accelerometer data to better understand the association between sedentary time and health in various populations. We collected two datasets, a laboratory-controlled dataset and a free-living dataset. We trained machine learning classifiers separately on each dataset and compared performance across datasets. The classifiers predict five postures: sit, stand, sit-stand, stand-sit, and stand\\walk. We compared a manually constructed Hidden Markov model (HMM) with an automated HMM from existing software. The manually constructed HMM gave more F1-Macro score on both datasets.

  4. Repeated Stand-Replacing Crown Fires Affect Seed Morphology and Germination in Aleppo pine.

    PubMed

    Saracino, Antonio; Bellino, Alessandro; Allevato, Emilia; Mingo, Antonio; Conti, Stefano; Rossi, Sergio; Bonanomi, Giuliano; Carputo, Domenico; Mazzoleni, Stefano

    2017-01-01

    Post-fire reproductive niche of Aleppo pine ( Pinus halepensis ) is deeply interlaced with fire products. Indeed, the high pH and low osmotic potentials of ash beds under burnt crowns constitute the main constraints to seed germination. In this study, we aim to investigate whether fire recurrence, through the physico-chemical constraints imposed by the ash beds, affects the reproduction ability of P. halepensis at the germination stage. To this aim, Aleppo pine seeds were collected in neighboring even-aged stands subjected to 0, 1, or 2 fires (namely fire cohorts), and seed morphology and germination performance, in terms of cumulative germination and germination kinetics, were studied under increasing osmotic potentials (from 0.0 to -1.2 MPa) and pH (from 6 to 11). Besides fire history, the role of ontogenetic age of mother plants on seed morphology and germination was also investigated. Differences in seed morphology among the three cohorts have been highlighted in a multivariate context, with anisotropic enlargement of the seeds produced by pine stands experiencing repeated fires. The patterns of seed germination varied primarily in relation to the fire cohort, with seeds from the pine stand experiencing repeated fires exhibiting enhanced tolerance to pH stress. Conversely, germination performances under osmotic constraints mainly depends on tree ontogenetic stage, with an involvement of fire history especially in the timing of seed germination. Our results suggest that, at least in the short term, fire recurrence does not constrain the reproduction ability of Aleppo pine. These results highlight the need for further research to elucidate the mechanisms behind these responses to recurrent fires.

  5. Effects of Stand and Step Training with Epidural Stimulation on Motor Function for Standing in Chronic Complete Paraplegics

    PubMed Central

    Rejc, Enrico; Angeli, Claudia A.; Bryant, Nicole

    2017-01-01

    Abstract Individuals affected by motor complete spinal cord injury are unable to stand, walk, or move their lower limbs voluntarily; this diagnosis normally implies severe limitations for functional recovery. We have recently shown that the appropriate selection of epidural stimulation parameters was critical to promoting full-body, weight-bearing standing with independent knee extension in four individuals with chronic clinically complete paralysis. In the current study, we examined the effects of stand training and subsequent step training with epidural stimulation on motor function for standing in the same four individuals. After stand training, the ability to stand improved to different extents in the four participants. Step training performed afterwards substantially impaired standing ability in three of the four individuals. Improved standing ability generally coincided with continuous electromyography (EMG) patterns with constant levels of ground reaction forces. Conversely, poorer standing ability was associated with more variable EMG patterns that alternated EMG bursts and longer periods of negligible activity in most of the muscles. Stand and step training also differentially affected the evoked potentials amplitude modulation induced by sitting-to-standing transition. Finally, stand and step training with epidural stimulation were not sufficient to improve motor function for standing without stimulation. These findings show that the spinal circuitry of motor complete paraplegics can generate motor patterns effective for standing in response to task-specific training with optimized stimulation parameters. Conversely, step training can lead to neural adaptations resulting in impaired motor function for standing. PMID:27566051

  6. High-performance supercapacitors based on hollow polyaniline nanofibers by electrospinning.

    PubMed

    Miao, Yue-E; Fan, Wei; Chen, Dan; Liu, Tianxi

    2013-05-22

    Hollow polyaniline (PANI) nanofibers with controllable wall thickness are fabricated by in situ polymerization of aniline using the electrospun poly(amic acid) fiber membrane as a template. A maximum specific capacitance of 601 F g(-1) has been achieved at 1 A g(-1), suggesting the potential application of hollow PANI nanofibers for supercapacitors. The superior electrochemical performance of the hollow nanofibers is attributed to their hollow structure, thin wall thickness, and orderly pore passages, which can drastically facilitate the ion diffusion and improve the utilization of the electroactive PANI during the charge-discharge processes. Furthermore, the high flexibility of the self-standing fiber membrane template provides possibilities for the facile construction and fabrication of conducting polymers with hollow nanostructures, which may find potential applications in various high-performance electrochemical devices.

  7. Productivity of a mature Douglas-fir stand.

    Treesearch

    Carl M. Berntsen

    1960-01-01

    Records from a mature Douglas-fir stand on the Mount Hood National Forest in northwestern Oregon indicate that very high rates of gross growth are maintained up to ages as high as 250 years. Where such stands are held in reserve for future clear cutting, forest managers have an opportunity to recapture a large share of this gross production by salvaging mortality at...

  8. Object-oriented classification of forest structure from light detection and ranging data for stand mapping

    Treesearch

    Alicia A. Sullivan; Robert J. McGaughey; Hans-Erik Andersen; Peter Schiess

    2009-01-01

    Stand delineation is an important step in the process of establishing a forest inventory and provides the spatial framework for many forest management decisions. Many methods for extracting forest structure characteristics for stand delineation and other purposes have been researched in the past, primarily focusing on high-resolution imagery and satellite data. High-...

  9. Effects of Short-Term Isokinetic Training on Standing Long-Jump Performance in Untrained Men.

    ERIC Educational Resources Information Center

    Morriss, Calvin J.; Tolfrey, Keith; Coppack, Russell J.

    2001-01-01

    Evaluated the effects of a brief isokinetic training program on quadriceps and hamstring peak torque (PT) and standing long-jump performance. Tests on 12 untrained men indicated that the brief training program was at least as effective in improving quadriceps isokinetic (but not hamstring) PT. PT gains subsequent to isokinetic resistance training…

  10. Calibration of photo sensors for the space-based cosmic ray telescope JEM-EUSO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karus, Michael

    2015-02-24

    In order to unveil the mystery of ultra-high energy cosmic rays (UHECRs), the planned fluorescence telescope JEM-EUSO (Extreme Universe Space Observatory on-board Japanese Experiment Module) will observe extensive air showers induced by UHECRs from the International Space Station (ISS) orbit with a huge acceptance. The JEM-EUSO instrument consists of Fresnel optics and a focal surface detector with 5000 multi-anode photomultiplier tubes (MAPMTs), 300000 channels in total. For fluorescence detection of cosmic rays it is essential to calibrate the detector pre-flight with utmost precision and to monitor the performance of the detector throughout the whole mission time. For that purpose amore » calibration stand on-ground was built to measure precisely the performance of Hamamatsu 64 pixel MAPMTs that are planned to be used for JEM-EUSO. To investigate the suitability of alternative detector devices, further research is done with state-of-the-art silicon photomultipliers (SiPMs), namely Hamamatsu multi-pixel photon counters (MPPCs). These will also be tested in the calibration stand and their performance can be compared to conventional photomultiplier tubes.« less

  11. Electrical Detection of C-Reactive Protein Using a Single Free-Standing, Thermally Controlled Piezoresistive Microcantilever for Highly Reproducible and Accurate Measurements

    PubMed Central

    Yen, Yi-Kuang; Lai, Yu-Cheng; Hong, Wei-Ting; Pheanpanitporn, Yotsapoom; Chen, Chuin-Shan; Huang, Long-Sun

    2013-01-01

    This study demonstrates a novel method for electrical detection of C-reactive protein (CRP) as a means of identifying an infection in the body, or as a cardiovascular disease risk assay. The method uses a single free-standing, thermally controlled piezoresistive microcantilever biosensor. In a commonly used sensing arrangement of conventional dual cantilevers in the Wheatstone bridge circuit, reference and gold-coated sensing cantilevers that inherently have heterogeneous surface materials and different multilayer structures may yield independent responses to the liquid environmental changes of chemical substances, flow field and temperature, leading to unwanted signal disturbance for biosensing targets. In this study, the single free-standing microcantilever for biosensing applications is employed to resolve the dual-beam problem of individual responses in chemical solutions and, in a thermally controlled system, to maintain its sensor performance due to the sensitive temperature effect. With this type of single temperature-controlled microcantilever sensor, the electrical detection of various CRP concentrations from 1 μg/mL to 200 μg/mL was performed, which covers the clinically relevant range. Induced surface stresses were measured at between 0.25 N/m and 3.4 N/m with high reproducibility. Moreover, the binding affinity (KD) of CRP and anti-CRP interaction was found to be 18.83 ± 2.99 μg/mL, which agreed with results in previous reported studies. This biosensing technique thus proves valuable in detecting inflammation, and in cardiovascular disease risk assays. PMID:23899933

  12. A compact electron cyclotron resonance proton source for the Paul Scherrer Institute's proton accelerator facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baumgarten, C.; Barchetti, A.; Einenkel, H.

    2011-05-15

    A compact electron cyclotron resonance proton source has been developed and installed recently at thePaul Scherrer Institute's high intensity proton accelerator. Operation at the ion source test stand and the accelerator demonstrates a high reliability and stability of the new source. When operated at a 10 - 12 mA net proton current the lifetime of the source exceeds 2000 h. The essential development steps towards the observed performance are described.

  13. Study of Stand-Alone Microgrid under Condition of Faults on Distribution Line

    NASA Astrophysics Data System (ADS)

    Malla, S. G.; Bhende, C. N.

    2014-10-01

    The behavior of stand-alone microgrid is analyzed under the condition of faults on distribution feeders. During fault since battery is not able to maintain dc-link voltage within limit, the resistive dump load control is presented to do so. An inverter control is proposed to maintain balanced voltages at PCC under the unbalanced load condition and to reduce voltage unbalance factor (VUF) at load points. The proposed inverter control also has facility to protect itself from high fault current. Existing maximum power point tracker (MPPT) algorithm is modified to limit the speed of generator during fault. Extensive simulation results using MATLAB/SIMULINK established that the performance of the controllers is quite satisfactory under different fault conditions as well as unbalanced load conditions.

  14. Functional Task Test: 2. Spaceflight-Induced Cardiovascular Change and Recovery During NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Phillips, Tiffany; Arzeno, Natalia M.; Stenger, Michael; Lee, Stuart M. C.; Bloomberg, Jacob J.; Platts, Steven H.

    2011-01-01

    The overall objective of the functional task test (FTT) is to correlate spaceflight-induced physiological adaptations with changes in performance of high priority exploration mission-critical tasks. This presentation will focus on the recovery from fall/stand test (RFST), which measures the cardiovascular response to the transition from the prone posture (simulated fall) to standing in normal gravity, as well as heart rate (HR) during 11 functional tasks. As such, this test describes some aspects of spaceflight-induced cardiovascular deconditioning and the course of recovery in Space Shuttle and International Space Station (ISS) astronauts. The sensorimotor and neuromuscular components of the FTT are described in two separate abstracts: Functional Task Test 1 and 3.

  15. Adjustments of individual-tree survival and diameter-growth equations to match whole-stand attributes

    Treesearch

    Quang V. Cao

    2010-01-01

    Individual-tree models are flexible and can perform well in predicting tree survival and diameter growth for a certain growing period. However, the resulting stand-level outputs often suffer from accumulation of errors and subsequently cannot compete with predictions from whole-stand models, especially when the projection period lengthens. Evaluated in this study were...

  16. Design of Mechanism for Assisting Standing Movement Using Planar Linkage and Gear Train

    NASA Astrophysics Data System (ADS)

    Nango, Jun; Yoshizawa, Hisato; Liu, Jiajun

    The number of people who are in need of nursing care due to difficulties they experience with performing various activities of daily living is increasing. In particular, the action of standing up is performed frequently in daily life, and this action starts to induce pain in joints as people age. In this research, we develop a device whose seat plate follows the movement of the thigh in the action of standing up for the purpose of relieving the burden from the joints and reducing the effort associated with nursing care. The device is designed by using a planar five-link mechanism and a gear train, and only a single input is needed to drive the device. The respective lengths of the links are determined by comparing the movement of the seat plate of the device with the movement of the human thigh in the action of standing up. In addition, this device is expected to be useful for assisting users in standing up in a natural manner, including in the case when the body remains supported by the seat plate, as well as for guiding the individual movements of users in the action of standing up.

  17. Estimation of the stand ages of tropical secondary forests after shifting cultivation based on the combination of WorldView-2 and time-series Landsat images

    NASA Astrophysics Data System (ADS)

    Fujiki, Shogoro; Okada, Kei-ichi; Nishio, Shogo; Kitayama, Kanehiro

    2016-09-01

    We developed a new method to estimate stand ages of secondary vegetation in the Bornean montane zone, where local people conduct traditional shifting cultivation and protected areas are surrounded by patches of recovering secondary vegetation of various ages. Identifying stand ages at the landscape level is critical to improve conservation policies. We combined a high-resolution satellite image (WorldView-2) with time-series Landsat images. We extracted stand ages (the time elapsed since the most recent slash and burn) from a change-detection analysis with Landsat time-series images and superimposed the derived stand ages on the segments classified by object-based image analysis using WorldView-2. We regarded stand ages as a response variable, and object-based metrics as independent variables, to develop regression models that explain stand ages. Subsequently, we classified the vegetation of the target area into six age units and one rubber plantation unit (1-3 yr, 3-5 yr, 5-7 yr, 7-30 yr, 30-50 yr, >50 yr and 'rubber plantation') using regression models and linear discriminant analyses. Validation demonstrated an accuracy of 84.3%. Our approach is particularly effective in classifying highly dynamic pioneer vegetation younger than 7 years into 2-yr intervals, suggesting that rapid changes in vegetation canopies can be detected with high accuracy. The combination of a spectral time-series analysis and object-based metrics based on high-resolution imagery enabled the classification of dynamic vegetation under intensive shifting cultivation and yielded an informative land cover map based on stand ages.

  18. Axial acoustic radiation force on rigid oblate and prolate spheroids in Bessel vortex beams of progressive, standing and quasi-standing waves.

    PubMed

    Mitri, F G

    2017-02-01

    The analysis using the partial-wave series expansion (PWSE) method in spherical coordinates is extended to evaluate the acoustic radiation force experienced by rigid oblate and prolate spheroids centered on the axis of wave propagation of high-order Bessel vortex beams composed of progressive, standing and quasi-standing waves, respectively. A coupled system of linear equations is derived after applying the Neumann boundary condition for an immovable surface in a non-viscous fluid, and solved numerically by matrix inversion after performing a single numerical integration procedure. The system of linear equations depends on the partial-wave index n and the order of the Bessel vortex beam m using truncated but converging PWSEs in the least-squares sense. Numerical results for the radiation force function, which is the radiation force per unit energy density and unit cross-sectional surface, are computed with particular emphasis on the amplitude ratio describing the transition from the progressive to the pure standing waves cases, the aspect ratio (i.e., the ratio of the major axis over the minor axis of the spheroid), the half-cone angle and order of the Bessel vortex beam, as well as the dimensionless size parameter. A generalized expression for the radiation force function is derived for cases encompassing the progressive, standing and quasi-standing waves of Bessel vortex beams. This expression can be reduced to other types of beams/waves such as the zeroth-order Bessel non-vortex beam or the infinite plane wave case by appropriate selection of the beam parameters. The results for progressive waves reveal a tractor beam behavior, characterized by the emergence of an attractive pulling force acting in opposite direction of wave propagation. Moreover, the transition to the quasi-standing and pure standing wave cases shows the acoustical tweezers behavior in dual-beam Bessel vortex beams. Applications in acoustic levitation, particle manipulation and acousto-fluidics would benefit from the results of the present investigation. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Effects of DanceSport on walking balance and standing balance among the elderly.

    PubMed

    Sohn, Jeehoon; Park, Sung-Ha; Kim, Sukwon

    2018-05-04

    Dancesport is a popular activity among older adults who look for fun and fitness in Korea. Studies reported positive sociological and psychological effects of dancesport. But, little studies were performed to evaluate the effects of dancesport on balance performances. The objective of the present study was to evaluate the effects of dancesport for 15 weeks on walking balance and standing balance of older adults. Older adults regularly participated in the dancesport program 3 times a week for 15 weeks. The program included Rumba, Cha-cha-cha, and Jive. They exercised the prescribed dancesport at intermediate level for 50-60 mins for each time. A total 22 reflective markers were placed on the anatomical landmarks and 8 cameras were used to measure 3-D positions of participants. Also, center of pressure (COP) data were measured to analyze standing balance using a ground reaction board at 1200 Hz for 30 seconds. One-way analysis of variance (ANOVA) was performed to test the effects of 15 weeks of dancesport on walking balance and standing balance. The results suggested that, after 15 weeks of dancesport participation, older adults' walking balance (48.3 ± 20.3 cm2 vs 38.2 ± 18.2 cm2) and standing balance (COP area: 189.4 ± 85.4 mm2 vs 103.5 ± 55.4mm2, COP distance: 84.2 ± 34.4 cm vs 76.5 ± 21.4 cm) were significantly improved. Performing dancesport would require moving center of mass rapidly and frequently while maintaining posture. This may result in improving walking balance and standing balance in the present study. The study concluded that dancesport would be an effective exercise method in enhancing postural stability of older adults.

  20. High-energy asymmetric supercapacitors based on free-standing hierarchical Co-Mo-S nanosheets with enhanced cycling stability.

    PubMed

    Balamurugan, Jayaraman; Li, Chao; Peera, Shaik Gouse; Kim, Nam Hoon; Lee, Joong Hee

    2017-09-21

    Layered transition metal sulfides (TMS) are emerging as advanced materials for energy storage and conversion applications. In this work, we report a facile and cost-effective anion exchange technique to fabricate a layered, multifaceted, free standing, ultra-thin ternary cobalt molybdenum sulfide nanosheet (Co-Mo-S NS) architecture grown on a 3D porous Ni foam substrate. The unique Co-Mo layered double hydroxides are first synthesized as precursors and consequently transformed into ultra-thin Co-Mo-S NS. When employed as an electrode for supercapacitors, the Co-Mo-S NS delivered an ultra-high specific capacitance of 2343 F g -1 at a current density of 1 mA cm -2 with tremendous rate capability and extraordinary cycling performance (96.6% capacitance retention after 20 000 cycles). Furthermore, assembled Co-Mo-S/nitrogen doped graphene nanosheets (NGNS) in an asymmetric supercapacitor (ASC) device delivered an excellent energy density of 89.6 Wh kg -1 , an amazing power density of 20.07 kW kg -1 , and superior cycling performance (86.8% capacitance retention after 50 000 cycles). Such exceptional electrochemical performance of Co-Mo-S NS is ascribed to the good electrical contact with the 3D Ni foam, ultra-high contact area with the electrolyte, and enhanced architectural softening during the charging/discharging process. It is expected that the fabricated, unique, ultra-thin Co-Mo-S NS have great potential for future energy storage devices.

  1. How the World's Best Schools Stay on Top: Study's Key Findings Pinpoint Practices That Align with Learning Forward

    ERIC Educational Resources Information Center

    Killion, Joellen

    2016-01-01

    Key findings from a new study highlight how Learning Forward's long-standing position on professional learning correlates with practices in high-performing systems in Singapore, Shanghai, Hong Kong, and British Columbia. The purpose of this article is to share key findings from the study so that educators might apply them to strengthening…

  2. Performance on large-scale science tests: Item attributes that may impact achievement scores

    NASA Astrophysics Data System (ADS)

    Gordon, Janet Victoria

    Significant differences in achievement among ethnic groups persist on the eighth-grade science Washington Assessment of Student Learning (WASL). The WASL measures academic performance in science using both scenario and stand-alone question types. Previous research suggests that presenting target items connected to an authentic context, like scenario question types, can increase science achievement scores especially in underrepresented groups and thus help to close the achievement gap. The purpose of this study was to identify significant differences in performance between gender and ethnic subgroups by question type on the 2005 eighth-grade science WASL. MANOVA and ANOVA were used to examine relationships between gender and ethnic subgroups as independent variables with achievement scores on scenario and stand-alone question types as dependent variables. MANOVA revealed no significant effects for gender, suggesting that the 2005 eighth-grade science WASL was gender neutral. However, there were significant effects for ethnicity. ANOVA revealed significant effects for ethnicity and ethnicity by gender interaction in both question types. Effect sizes were negligible for the ethnicity by gender interaction. Large effect sizes between ethnicities on scenario question types became moderate to small effect sizes on stand-alone question types. This indicates the score advantage the higher performing subgroups had over the lower performing subgroups was not as large on stand-alone question types compared to scenario question types. A further comparison examined performance on multiple-choice items only within both question types. Similar achievement patterns between ethnicities emerged; however, achievement patterns between genders changed in boys' favor. Scenario question types appeared to register differences between ethnic groups to a greater degree than stand-alone question types. These differences may be attributable to individual differences in cognition, characteristics of test items themselves and/or opportunities to learn. Suggestions for future research are made.

  3. Trajectories of Lower Extremity Physical Performance: Effects on Fractures and Mortality in Older Women.

    PubMed

    Barbour, Kamil E; Lui, Li-Yung; McCulloch, Charles E; Ensrud, Kristine E; Cawthon, Peggy M; Yaffe, Kristine; Barnes, Deborah E; Fredman, Lisa; Newman, Anne B; Cummings, Steven R; Cauley, Jane A

    2016-12-01

    Prior studies have only considered one measurement of physical performance in its relationship to fractures and mortality. A single measurement is susceptible to large within-person changes over time, and thus, may not capture the true association between physical performance and the outcomes of interest. Using data from the Study of Osteoporotic Fractures, we followed 7,015 women enrolled prior to age 80 years who had outcome information beyond this age. Trajectories of walking speed (m/s) and chair stand speed (stands/s) were estimated up to the last visit prior to age 80 years using mixed-effects linear regression. Physical performance at age 80 (PF_age80) was assessed at the last visit prior to age 80 years. Hazard ratios (HRs) and 95% confidence intervals (CIs) were estimated using Cox proportional hazards regression and multivariate models adjusted for all other covariates. Greatest walking speed decline and chair stand speed decline were both associated with higher risk of hip fracture (HR: 1.28; 95% CI: 1.03, 1.58 and HR: 1.26; 95% CI: 1.03, 1.54, respectively), but not nonspine fractures. Greatest walking speed decline and chair stand speed decline were both associated with a significant 29% (95% CI: 17-42%) and 27% (95% CI: 15-39%) increased risk of mortality, respectively. Greatest declines in walking speed and chair stand speed were both associated with an increased risk of hip fracture and mortality independent of PF_age80 and other important confounders. Both physical performance change and the single physical performance measurement should be considered in the etiology of hip fracture and mortality. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  4. Heteromorphic NiCo2S4/Ni3S2/Ni Foam as a Self-Standing Electrode for Hydrogen Evolution Reaction in Alkaline Solution.

    PubMed

    Liu, Hui; Ma, Xiao; Rao, Yuan; Liu, Yang; Liu, Jialiang; Wang, Luyang; Wu, Mingbo

    2018-04-04

    Considerable works have been devoted on developing high-efficiency nonplatinum electrocatalysts for hydrogen evolution reaction (HER). Herein, 3D heteromorphic NiCo 2 S 4 /Ni 3 S 2 nanosheets network has been constructed on Ni foam (denoted as NiCo 2 S 4 /Ni 3 S 2 /NF) serving as a self-standing electrocatalyst through directly thermal sulfurization of a single-source NiCo-layered double hydroxide precursor. The resultant NiCo 2 S 4 /Ni 3 S 2 /NF electrode exhibits outstanding electrocatalytic HER performance with an extremely low onset overpotential of 15 mV and long-term durability in alkaline solution. Such enhanced HER performance can be credited to (1) the massive exposed active sites provided by mixed transition metal chalcogenides (NiCo 2 S 4 and Ni 3 S 2 ), (2) the strong interfacial interaction at NiCo 2 S 4 /Ni 3 S 2 heterojunction interfaces with the strengthened H binding, and (3) the porous highly conductive Ni foam substrate with accelerated electron transfer. This work opens up a new direction to fabricate effective and non-noble-metal electrodes for water splitting and hydrogen generation.

  5. The association of ACE, ACTN3 and PPARA gene variants with strength phenotypes in middle school-age children.

    PubMed

    Ahmetov, Ildus I; Gavrilov, Dmitry N; Astratenkova, Irina V; Druzhevskaya, Anastasiya M; Malinin, Alexandr V; Romanova, Elena E; Rogozkin, Victor A

    2013-01-01

    The aim of the study was to determine the association between ACE I/D, ACTN3 R577X and PPARA intron 7 G/C gene polymorphisms and strength-related traits in 457 middle school-age children (219 boys and 238 girls; aged 11 ± 0.4 years). The assessment of different phenotypes was conducted with a number of performance tests. Gene polymorphisms were determined by PCR. The ACE D allele was associated with high results of standing long-jump test in boys [II 148.3 (16.3) cm, ID 152.6 (19.6) cm, DD 158.2 (19.1) cm; P = 0.037]. The ACTN3 R allele was associated with high results of performance tests in males only in combination with other genes (standing long-jump test: P = 0.021; handgrip strength test: P < 0.0001). Furthermore, the male carriers of the PPARA gene C allele demonstrated the best results of handgrip strength testing than GG homozygotes [GG 14.6 (4.0) kg, GC/CC 15.7 (4.3) kg; P = 0.048]. Thus, the ACE, ACTN3 and PPARA gene variants are associated with strength-related traits in physically active middle school-age boys.

  6. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis moves into high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis moves into high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  7. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis is moved into high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis is moved into high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  8. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis approaches the Vehicle Assembly Building (VAB) high bay 4. It is being towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis approaches the Vehicle Assembly Building (VAB) high bay 4. It is being towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  9. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis approaches high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis approaches high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  10. KENNEDY SPACE CENTER, FLA. - Workers walk with Space Shuttle orbiter Atlantis from the Orbiter Processing Facility (OPF) to the Vehicle Assembly Building (VAB) high bay 4. The move will allow work to be performed in the OPF that can only be accomplished while the bay is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - Workers walk with Space Shuttle orbiter Atlantis from the Orbiter Processing Facility (OPF) to the Vehicle Assembly Building (VAB) high bay 4. The move will allow work to be performed in the OPF that can only be accomplished while the bay is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  11. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis arrives in high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis arrives in high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  12. KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis is almost in position in high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

    NASA Image and Video Library

    2003-12-05

    KENNEDY SPACE CENTER, FLA. - The Space Shuttle orbiter Atlantis is almost in position in high bay 4 of the Vehicle Assembly Building (VAB). It was towed from the Orbiter Processing Facility (OPF) to allow work to be performed in the bay that can only be accomplished while it is empty. Work scheduled in the processing facility includes annual validation of the bay's cranes, work platforms, lifting mechanisms, and jack stands. Atlantis will remain in the VAB for about 10 days, then return to the OPF as work resumes to prepare it for launch in September 2004 on the first return-to-flight mission, STS-114.

  13. Effect of epidural blood injection on upright posture intolerance in patients with headaches due to intracranial hypotension: A prospective study.

    PubMed

    Qureshi, Adnan I; Kherani, Danish; Waqas, Muhammad A; Qureshi, Mushtaq H; Raja, Faisal M; Wallery, Shawn S

    2018-06-19

    We performed a prospective study to quantify changes in various aspects of upright posture intolerance in patients with intracranial hypotension. Six patients were provided a standard questionnaire before, immediately after epidural blood patch injection and at follow-up visit within 1 month after epidural blood injection inquiring: (a) How long can they stand straight without any support? (b) Do they feel any sense of sickness when they sit or lie down after standing? (c) How long do they have to wait before they are comfortable standing again after they have stood straight? (d) How effectively and fast can they get up from sitting or lying position to stand straight? and (e) Rate their activities in upright posture without support on a standard vertical visual analogue scale between 100 (can do everything) and 0 (cannot do anything). All patients responded that they could not stand straight for ≥30 min (four responding <5 min) on pretreatment evaluation. All patients reported improvement in this measure immediately postprocedure with two reporting ≥30 min. At follow-up, three patients reported further improvement and one patient reported worsening in this measure. The magnitude of improvement ranged from 10 to 80 points increase immediately postprocedure in their ability to perform activities, while they are standing without any support on visual analogue scale. At follow-up, four patient reported additional improvement in their ability to perform activities, while they are standing without any support (ranged from 10 to 20 points increase compared with immediately postprocedure rating). We present semiquantitative data on various aspects of upright posture intolerance in patients with intracranial hypotension before and after epidural blood injection. © 2018 The Authors. Brain and Behavior published by Wiley Periodicals, Inc.

  14. Tree grades, yields and values for some Appalachian hardwoods

    Treesearch

    Robert A. Campbell

    1951-01-01

    Foresters ahve long recognized the need for a better method of appraising standing timber in terms of quality as well as volume of lumber that trees may be expected to produce. Because the range in price between high-grade lumber and low-grade lumber is extremely wide, a stand of high-quality timber is much more valuable than a low-quality stand. In spite of this,...

  15. Response of sapling stands to cultural treatments

    Treesearch

    H. Clay Smith

    1989-01-01

    The main reasons for precommercial cultural practices in sapling stands (trees less than 5 inches d.b.h.) are to increase growth of residual trees, increase stand value, and improve or maintain species composition. On good sites (northern red oak site index 70 and above), treating sapling stands may be justified by increased diameter growth of high value species. On...

  16. Clinical Tests of Standing Balance in the Knee Osteoarthritis Population: Systematic Review and Meta-analysis

    PubMed Central

    Hatfield, Gillian L.; Morrison, Adam; Wenman, Matthew; Hammond, Connor A.

    2016-01-01

    Background People with knee osteoarthritis (OA) have a high prevalence of falls. Poor standing balance is one risk factor, but the extent of standing balance deficits in people with knee OA is unknown. Purpose The primary purpose of this study was to summarize available data on standing balance in people with knee OA compared with people without knee OA. A secondary purpose was to establish the extent of balance impairment across disease severity. Data Sources A literature search of the MEDLINE, EMBASE, CINAHL, and Web of Science databases through November 19, 2014, was conducted. Study Selection Studies on individuals with knee OA containing clinical, quantifiable measures of standing balance were included. Methodological quality was assessed by 2 reviewers using a 16-item quality index developed for nonrandomized studies. Studies scoring >50% on the index were included. Data Extraction Participant characteristics (age, sex, body mass index, OA severity, compartment involvement, unilateral versus bilateral disease) and balance outcomes were extracted by 2 reviewers. Standardized mean differences were pooled using a random-effects model. Data Synthesis The search yielded 2,716 articles; 8 met selection and quality assessment criteria. The median score on the quality index was 13/17. People with knee OA consistently performed worse than healthy controls on the Step Test, Single-Leg Stance Test, Functional Reach Test, Tandem Stance Test, and Community Balance and Mobility Scale. The pooled standardized mean difference was −1.64 (95% confidence interval=−2.58, −0.69). No differences were observed between varying degrees of malalignment, or between unilateral versus bilateral disease. Limitations No studies compared between-knee OA severities. Thus, expected changes in balance as the disease progresses remain unknown. Conclusions Few studies compared people with knee OA and healthy controls, but those that did showed that people with knee OA performed significantly worse. More research is needed to understand the extent of balance impairments in people with knee OA using easy-to-administer, clinically available tests. PMID:26183586

  17. Single- and Dual-Task Balance Training Are Equally Effective in Youth

    PubMed Central

    Lüder, Benjamin; Kiss, Rainer; Granacher, Urs

    2018-01-01

    Due to maturation of the postural control system and secular declines in motor performance, adolescents experience deficits in postural control during standing and walking while concurrently performing cognitive interference tasks. Thus, adequately designed balance training programs may help to counteract these deficits. While the general effectiveness of youth balance training is well-documented, there is hardly any information available on the specific effects of single-task (ST) versus dual-task (DT) balance training. Therefore, the objectives of this study were (i) to examine static/dynamic balance performance under ST and DT conditions in adolescents and (ii) to study the effects of ST versus DT balance training on static/dynamic balance under ST and DT conditions in adolescents. Twenty-eight healthy girls and boys aged 12–13 years were randomly assigned to either 8 weeks of ST or DT balance training. Before and after training, postural sway and spatio-temporal gait parameters were registered under ST (standing/walking only) and DT conditions (standing/walking while concurrently performing an arithmetic task). At baseline, significantly slower gait speed (p < 0.001, d = 5.1), shorter stride length (p < 0.001, d = 4.8), and longer stride time (p < 0.001, d = 3.8) were found for DT compared to ST walking but not standing. Training resulted in significant pre–post decreases in DT costs for gait velocity (p < 0.001, d = 3.1), stride length (-45%, p < 0.001, d = 2.4), and stride time (-44%, p < 0.01, d = 1.9). Training did not induce any significant changes (p > 0.05, d = 0–0.1) in DT costs for all parameters of secondary task performance during standing and walking. Training produced significant pre–post increases (p = 0.001; d = 1.47) in secondary task performance while sitting. The observed increase was significantly greater for the ST training group (p = 0.04; d = 0.81). For standing, no significant changes were found over time irrespective of the experimental group. We conclude that adolescents showed impaired DT compared to ST walking but not standing. ST and DT balance training resulted in significant and similar changes in DT costs during walking. Thus, there appears to be no preference for either ST or DT balance training in adolescents. PMID:29928248

  18. Single- and Dual-Task Balance Training Are Equally Effective in Youth.

    PubMed

    Lüder, Benjamin; Kiss, Rainer; Granacher, Urs

    2018-01-01

    Due to maturation of the postural control system and secular declines in motor performance, adolescents experience deficits in postural control during standing and walking while concurrently performing cognitive interference tasks. Thus, adequately designed balance training programs may help to counteract these deficits. While the general effectiveness of youth balance training is well-documented, there is hardly any information available on the specific effects of single-task (ST) versus dual-task (DT) balance training. Therefore, the objectives of this study were (i) to examine static/dynamic balance performance under ST and DT conditions in adolescents and (ii) to study the effects of ST versus DT balance training on static/dynamic balance under ST and DT conditions in adolescents. Twenty-eight healthy girls and boys aged 12-13 years were randomly assigned to either 8 weeks of ST or DT balance training. Before and after training, postural sway and spatio-temporal gait parameters were registered under ST (standing/walking only) and DT conditions (standing/walking while concurrently performing an arithmetic task). At baseline, significantly slower gait speed ( p < 0.001, d = 5.1), shorter stride length ( p < 0.001, d = 4.8), and longer stride time ( p < 0.001, d = 3.8) were found for DT compared to ST walking but not standing. Training resulted in significant pre-post decreases in DT costs for gait velocity ( p < 0.001, d = 3.1), stride length (-45%, p < 0.001, d = 2.4), and stride time (-44%, p < 0.01, d = 1.9). Training did not induce any significant changes ( p > 0.05, d = 0-0.1) in DT costs for all parameters of secondary task performance during standing and walking. Training produced significant pre-post increases ( p = 0.001; d = 1.47) in secondary task performance while sitting. The observed increase was significantly greater for the ST training group ( p = 0.04; d = 0.81). For standing, no significant changes were found over time irrespective of the experimental group. We conclude that adolescents showed impaired DT compared to ST walking but not standing. ST and DT balance training resulted in significant and similar changes in DT costs during walking. Thus, there appears to be no preference for either ST or DT balance training in adolescents.

  19. Perspectives on a ‘Sit Less, Move More’ Intervention in Australian Emergency Call Centres

    PubMed Central

    Chau, Josephine Y; Engelen, Lina; Burks-Young, Sarah; Daley, Michelle; Maxwell, Jen-Kui; Milton, Karen; Bauman, Adrian

    2016-01-01

    Background Prolonged sitting is associated with increased risk of chronic diseases. Workplace programs that aim to reduce sitting time (sit less) and increase physical activity (move more) have targeted desk-based workers in corporate and university settings with promising results. However, little is known about ‘move more, sit less’ programs for workers in other types of jobs and industries, such as shift workers. This formative research examines the perceptions of a ‘sit less, move more’ program in an Australian Emergency Call Centre that operates 24 hours per day, 7 days per week. Methods Participants were employees (N = 39, 72% female, 50% aged 36–55 years) recruited from Emergency Services control centres located in New South Wales, Australia. The ‘sit less, move more’ intervention, consisting of emails, posters and timer lights, was co-designed with the management team and tailored to the control centre environment and work practices, which already included electronic height-adjustable sit-stand workstations for all call centre staff. Participants reported their perceptions and experiences of the intervention in a self-report online questionnaire, and directly to the research team during regular site visits. Questionnaire topics included barriers and facilitators to standing while working, mental wellbeing, effects on work performance, and workplace satisfaction. Field notes and open-ended response data were analysed in an iterative process during and after data collection to identify the main themes. Results Whilst participants already had sit-stand workstations, use of the desks in the standing position varied and sometimes were contrary to expectations (e.g, less tired standing than sitting; standing when experiencing high call stress). Participants emphasised the “challenging” and “unrelenting” nature of their work. They reported sleep issues (“always tired”), work stress (“non-stop demands”), and feeling mentally and physically drained due to shift work and length of shifts. Overall, participants liked the initiative but acknowledged that their predominantly sitting habits were entrenched and work demands took precedence. Conclusions This study demonstrates the low acceptability of a ‘sit less, move more’ program in shift workers in high stress environments like emergency call centres. Work demands take priority and other health concerns, like poor sleep and high stress, may be more salient than the need to sit less and move more during work shifts. PMID:29546163

  20. Perspectives on a 'Sit Less, Move More' Intervention in Australian Emergency Call Centres.

    PubMed

    Chau, Josephine Y; Engelen, Lina; Burks-Young, Sarah; Daley, Michelle; Maxwell, Jen-Kui; Milton, Karen; Bauman, Adrian

    2016-01-01

    Prolonged sitting is associated with increased risk of chronic diseases. Workplace programs that aim to reduce sitting time (sit less) and increase physical activity (move more) have targeted desk-based workers in corporate and university settings with promising results. However, little is known about 'move more, sit less' programs for workers in other types of jobs and industries, such as shift workers. This formative research examines the perceptions of a 'sit less, move more' program in an Australian Emergency Call Centre that operates 24 hours per day, 7 days per week. Participants were employees (N = 39, 72% female, 50% aged 36-55 years) recruited from Emergency Services control centres located in New South Wales, Australia. The 'sit less, move more' intervention, consisting of emails, posters and timer lights, was co-designed with the management team and tailored to the control centre environment and work practices, which already included electronic height-adjustable sit-stand workstations for all call centre staff. Participants reported their perceptions and experiences of the intervention in a self-report online questionnaire, and directly to the research team during regular site visits. Questionnaire topics included barriers and facilitators to standing while working, mental wellbeing, effects on work performance, and workplace satisfaction. Field notes and open-ended response data were analysed in an iterative process during and after data collection to identify the main themes. Whilst participants already had sit-stand workstations, use of the desks in the standing position varied and sometimes were contrary to expectations (e.g, less tired standing than sitting; standing when experiencing high call stress). Participants emphasised the "challenging" and "unrelenting" nature of their work. They reported sleep issues ("always tired"), work stress ("non-stop demands"), and feeling mentally and physically drained due to shift work and length of shifts. Overall, participants liked the initiative but acknowledged that their predominantly sitting habits were entrenched and work demands took precedence. This study demonstrates the low acceptability of a 'sit less, move more' program in shift workers in high stress environments like emergency call centres. Work demands take priority and other health concerns, like poor sleep and high stress, may be more salient than the need to sit less and move more during work shifts.

  1. Wisdom of crowds for robust gene network inference

    PubMed Central

    Marbach, Daniel; Costello, James C.; Küffner, Robert; Vega, Nicci; Prill, Robert J.; Camacho, Diogo M.; Allison, Kyle R.; Kellis, Manolis; Collins, James J.; Stolovitzky, Gustavo

    2012-01-01

    Reconstructing gene regulatory networks from high-throughput data is a long-standing problem. Through the DREAM project (Dialogue on Reverse Engineering Assessment and Methods), we performed a comprehensive blind assessment of over thirty network inference methods on Escherichia coli, Staphylococcus aureus, Saccharomyces cerevisiae, and in silico microarray data. We characterize performance, data requirements, and inherent biases of different inference approaches offering guidelines for both algorithm application and development. We observe that no single inference method performs optimally across all datasets. In contrast, integration of predictions from multiple inference methods shows robust and high performance across diverse datasets. Thereby, we construct high-confidence networks for E. coli and S. aureus, each comprising ~1700 transcriptional interactions at an estimated precision of 50%. We experimentally test 53 novel interactions in E. coli, of which 23 were supported (43%). Our results establish community-based methods as a powerful and robust tool for the inference of transcriptional gene regulatory networks. PMID:22796662

  2. Effect of attentional focus strategies on peak force and performance in the standing long jump.

    PubMed

    Wu, Will F W; Porter, Jared M; Brown, Lee E

    2012-05-01

    Significant benefits in standing long jump performance have been demonstrated when subjects were provided verbal instructions that promoted an external focus of attention compared with an internal focus of attention, suggesting differences in ground reaction forces. The purpose of the present study was to evaluate peak force and jump performance between internal and external focus of attention strategies. Untrained subjects were assigned to both experimental conditions in which verbal instructions were provided to promote either an external or internal focus of attention. All subjects completed a total number of 5 standing long jumps. The results of the study demonstrated that the external focus of attention condition elicited significantly greater jump distance (153.6 ± 38.6 cm) than the internal focus of attention condition (139.5 ± 46.7 cm). There were no significant differences observed between conditions in peak force (1429.8 ± 289.1 N and 1453.7 ± 299.7 N, respectively). The results add to the growing body of literature describing the training and learning benefits of an external focus of attention. Practitioners should create standardized verbal instructions using an external focus of attention to maximize standing long jump performance.

  3. A comparison of trunk biomechanics, musculoskeletal discomfort and productivity during simulated sit-stand office work.

    PubMed

    Karakolis, Thomas; Barrett, Jeff; Callaghan, Jack P

    2016-10-01

    Sedentary office work has been shown to cause low back discomfort and potentially cause injury. Prolonged standing work has been shown to cause discomfort. The implementation of a sit-stand paradigm is hypothesised to mitigate discomfort and prevent injury induced by prolonged exposure to each posture in isolation. This study explored the potential of sit-stand to reduce discomfort and prevent injury, without adversely affecting productivity. Twenty-four participants performed simulated office work in three different conditions: sitting, standing and sit-stand. Variables measured included: perceived discomfort, L4-L5 joint loading and typing/mousing productivity. Working in a sit-stand paradigm was found to have the potential to reduce discomfort when compared to working in a sitting or standing only configuration. Sit-stand was found to be associated with reduced lumbar flexion during sitting compared to sitting only. Increasing lumbar flexion during prolonged sitting is a known injury mechanism. Therefore, sit-stand exhibited a potentially beneficial response of reduced lumbar flexion that could have the potential to prevent injury. Sit-stand had no significant effect on productivity. Practitioner Summary: This study has contributed foundational elements to guide usage recommendations for sit-stand workstations. The sit-stand paradigm can reduce discomfort; however, working in a sit-stand ratio of 15:5 min may not be the most effective ratio. More frequent posture switches may be necessary to realise the full benefit of sit-stand.

  4. The high-speed after-pulse measurement system for PMT

    NASA Astrophysics Data System (ADS)

    Cheng, Y.; Qian, S.; Ning, Z.; Xia, J.; Wang, Z.

    2018-05-01

    A system employing a desktop FADC has been developed to investigate the features of 8-inch Hamamatsu PMT R5912. The system stands out for its high-speed and informative results as a consequence of adopting fast waveform sampling technology. Recording the full waveforms allows us to perform pulse shape analysis. High-precision after-pulse time and charge distribution results are presented in this manuscript. Other characteristics of the photomultiplier tube, such as the gain of charge, dark rate and transit time spread, can be also obtained by this system.

  5. Large Field of View PIV Measurements of Air Entrainment by SLS SMAT Water Sound Suppression System

    NASA Astrophysics Data System (ADS)

    Stegmeir, Matthew; Pothos, Stamatios; Bissell, Dan

    2015-11-01

    Water-based sound suppressions systems have been used to reduce the acoustic impact of space vehicle launches. Water flows at a high rate during launch in order to suppress Engine Generated Acoustics and other potentially damaging sources of noise. For the Space Shuttle, peak flow rates exceeded 900,000 gallons per minute. Such large water flow rates have the potential to induce substantial entrainment of the surrounding air, affecting the launch conditions and generating airflow around the launch vehicle. Validation testing is necessary to quantify this impact for future space launch systems. In this study, PIV measurements were performed to map the flow field above the SMAT sub-scale launch vehicle scaled launch stand. Air entrainment effects generated by a water-based sound suppression system were studied. Mean and fluctuating fluid velocities were mapped up to 1m above the test stand deck and compared to simulation results. Measurements performed with NASA MSFC.

  6. High-performance tin oxide-nitrogen doped graphene aerogel hybrids as anode materials for lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Tan, Chunhui; Cao, Jing; Khattak, Abdul Muqsit; Cai, Feipeng; Jiang, Bo; Yang, Gai; Hu, Suqin

    2014-12-01

    Tin dioxide nanoparticles on nitrogen doped graphene aerogel (SnO2-NGA) hybrid are synthesized by one-step hydrothermal method and successfully applied in lithium-ion batteries as a free-standing anode. The electrochemical performance of SnO2-NGA hybrid is investigated by galvanostatic charge-discharge cycling, rate capability test, cyclic voltammetry and electrochemical impedance spectroscopy. It is found that the SnO2-NGA hybrid with freestanding spongy-like structure exhibit remarkable lithium storage capacity (1100 mAh g-1 after 100 cycles), good cycling stability and high rate capability. The outstanding performance is attributed to the uniform SnO2 nanoparticles, unique spongy-like structure and N doping defect for Li+ diffusion.

  7. Baffling or Baffled: Improve Your Acoustics.

    ERIC Educational Resources Information Center

    Abdoo, Frank B.

    1981-01-01

    Presents techniques for evaluating the acoustics (reverberation time, and standing waves and resonance phenomena) of a band performance room. Gives instructions for building and placing inexpensive baffles (free-standing, portable sound barriers) to correct room defects. (SJL)

  8. Overstory density affects field performance of underplanted red oak (Quercus rubra L.) in Ontario

    Treesearch

    Daniel C. Dey; William C. Parker

    1997-01-01

    Red oak seedlings were underplanted in a closed-canopy mature northern hardwood stand and an adjacent shelterwood in central Ontario. Overstory density effects on seedling survival and growth were assessed 2 yr after planting. After 2 yr, seedling survival was 90% in the uncut stand and over 99% in the shelterwood. Seedlings in the uncut stand experienced negligible or...

  9. Establishing Normative Reference Values for Standing Broad Jump Among Hungarian Youth.

    PubMed

    Saint-Maurice, Pedro F; Laurson, Kelly R; Kaj, Mónika; Csányi, Tamás

    2015-06-26

    The purpose of this study was to examine age and sex trends in anaerobic power assessed by a standing broad jump and to determine norm-referenced values for youth in Hungary. A sample of 2,427 Hungarian youth (1,360 boys and 1,067 girls) completed the standing broad jump twice, and the highest distance score was recorded. Quantile regression was used to fit standing broad jump trends across linear and quadratic functions of age. Statistical significance was determined with bootstrap confidence intervals and the Wald test with p < .05. Age-by-sex specific centiles were generated and the 50th percentile was used to describe the overall patterns. Standing broad jump scores increased steadily in boys from age 11 through 18 years with a discrete plateau at the end of adolescence. Girls' standing broad jump scores of those who performed above the median increased with age and plateaued later in the adolescence. Both linear and quadratic age terms were statistically significant predictors of standing broad jump trends across age (p < .05), but the relations varied depending on the percentile. The 50th percentile values resulted in 147.0 cm, 162.0 cm, 175.0 cm, 186.0 cm, 195.0 cm, 202.0 cm, 207.0 cm, and 210.0 cm for boys aged 11 to 18 years old, respectively, and 140.0 cm, 143.9 cm, 147.3 cm, 150.0 cm, 152.1 cm, 153.7 cm, 154.6 cm, and 155.0 cm for girls aged 11 to 18 years old, respectively. This study provides normative reference charts that take into account age and sex differences in standing broad jump performance. The proposed reference values can be used to interpret standing broad jump scores in Hungarian youth.

  10. Sequencing sit-to-stand and upright posture for mobility limitation assessment: determination of the timing of the task phases from force platform data.

    PubMed

    Mazzà, Claudia; Zok, Mounir; Della Croce, Ugo

    2005-06-01

    The identification of quantitative tools to assess an individual's mobility limitation is a complex and challenging task. Several motor tasks have been designated as potential indicators of mobility limitation. In this study, a multiple motor task obtained by sequencing sit-to-stand and upright posture was used. Algorithms based on data obtained exclusively from a single force platform were developed to detect the timing of the motor task phases (sit-to-stand, preparation to the upright posture and upright posture). To test these algorithms, an experimental protocol inducing predictable changes in the acquired signals was designed. Twenty-two young, able-bodied subjects performed the task in four different conditions: self-selected natural and high speed with feet kept together, and self-selected natural and high speed with feet pelvis-width apart. The proposed algorithms effectively detected the timing of the task phases, the duration of which was sensitive to the four different experimental conditions. As expected, the duration of the sit-to-stand was sensitive to the speed of the task and not to the foot position, while the duration of the preparation to the upright posture was sensitive to foot position but not to speed. In addition to providing a simple and effective description of the execution of the motor task, the correct timing of the studied multiple task could facilitate the accurate determination of variables descriptive of the single isolated phases, allowing for a more thorough description of the motor task and therefore could contribute to the development of effective quantitative functional evaluation tests.

  11. Rainfall partitioning and related hydrochemical fluxes in a diverse and in a mono specific (Phenakospermum guyannense) secondary vegetation stand in eastern Amazonia.

    PubMed

    Hölscher, D; Sá, T D A; Möller, R F; Denich, M; Fölster, H

    1998-04-01

    Rainfall partitioning into throughfall and stemflow was studied in a diverse and in a mono specific stand of secondary vegetation in Eastern Amazonia. The nutrient concentrations in the water were analysed in order to quantify the related hydrochemical fluxes. Secondary vegetation forms the fallow in the local shifting cultivation system and is usually dominated by shrubs and trees. Phenakospermum guyannense (Strelitziaceae), a banana-like herb, is one of the predominant non-woody species. The study was conducted during an 18-month period in a 2.5-year-old relatively species-rich stand and a 10-year-old stand dominated by P. guyannense. In a year with 1956 mm of rainfall 65% (1281 mm) of this quantity reached the soil as throughfall in the diverse stand and 38% (743 mm) in the mono specific stand. Stemflow was estimated to be 23% and 41% respectively. P. guyannense and Banara guianensis (Flacourtiaceae), a tree species, were causing these high funnelling effects. In the young diverse stand B. guianensis had a stemflow of more than 200 l year -1 and P. guyannense had a median flux of 77 l year -1 per pseudostem. In the older stand the taller plants of P.␣guyannense collected 644 l year -1 per pseudostem on the median. The reason for these high values could be the banana-like growth form of P. guyannense and the crown morphology of B. guianensis, which has inclined branches. The low proportion of throughfall and the high stemflow values differ from all previous studies in Amazonian primary forests. The proximity to the Atlantic Ocean strongly influenced the nutrient fluxes via rainfall at our study site. This becomes obvious from the high Na and Cl fluxes with rainfall (19.7 kg Na ha -1 year -1 , 37.2 kg Cl ha -1 year -1 ) which were approximately equal to the Na and Cl fluxes with the sum of throughfall and stemflow for both stands. K fluxes in throughfall and stemflow in both stands were higher than in rainfall by a factor of 8. The high K enrichment during the crown passage is assumed to be caused by a␣high K concentration in the leaf tissue resulting in enhanced leaching from the leaves. In months with low␣rainfall the concentrations of Ca, Mg, S and Cl in throughfall of the diverse stand were significantly higher than in months with high rainfall. This was mainly due to vegetation burns in the dry period, which resulted in ash deposition on the canopy and subsequent wash-off and solution of ash particles.

  12. Characteristics of Declining Forest Stands on the Allegheny National Forest

    Treesearch

    William H. McWilliams; Robert White; Stanford L. Arner; Christopher, A. Nowak; Susan L. Stout; Susan L. Stout

    1996-01-01

    Forest stands with advanced symptoms of forest decline located on the Allegheny National Forest in northwestern Pennsylvania were studied to describe contemporary stand structure and composition, and the status of regeneration. Across all 340 stands, 12 percent of the total basal area per acre was in dead trees and 16 percent was in trees at high risk of mortality. For...

  13. Log-grade volume distribution prediction models for tree species in red oak-sweetgum stands on US mid-south minor stream bottoms

    Treesearch

    George M. Banzhaf; Thomas G. Matney; Emily B. Schultz; James S. Meadows; J. Paul Jeffreys; William C. Booth; Gan Li; Andrew W. Ezell; Theodor D. Leininger

    2016-01-01

    Red oak (Quercus section Labatae)-sweetgum (Liquidambar styraciflua L.) stands growing on mid-south bottomland sites in the United States are well known for producing high-quality grade hardwood logs, but models for estimating the quantity and quality of standing grade wood in these stands have been unavailable. Prediction...

  14. Children's catching performance when the demands on the postural system is altered.

    PubMed

    Angelakopoulos, Georgios T; Tsorbatzoudis, Haralambos; Grouios, George

    2014-07-01

    In many dynamic interceptive actions performers need to integrate activity of manual and postural subsystems for successful performance. Groups of different skill level (poor and good catchers), (mean age = 9.1 and 9.4 respectively) were required to perform one-handed catches under different postural constraints: standing; standing in contact with a postural support aid by their side (PSAS) or to the left of their trunk (PSAF); Tandem; and sitting (control). Results revealed that, for poor catchers, the number of successful catches increased and grasp errors decreased significantly when sitting and with both postural aids in comparison with standing alone and Tandem conditions. Kinematic analyses showed that the postural aid devices reduced head sway in the anterior-posterior direction, while the PSAF reduced lateral head sway. The poor catchers' performance benefited from an enlarged support surface, and reduction of lateral sway. Good catchers performed successfully under all task constraints, signifying the existence of a functional relationship between postural and grasping subsystems during performance. The results are discussed in the frame of Bernstein's (1967) and Newell's (1986) theory.

  15. Vertically Aligned Co9 S8 Nanotube Arrays onto Graphene Papers as High-Performance Flexible Electrodes for Supercapacitors.

    PubMed

    Xiong, Dongbin; Li, Xifei; Bai, Zhimin; Li, Jianwei; Han, Yan; Li, Dejun

    2018-02-16

    Paper-like electrodes are emerging as a new category of advanced electrodes for flexible supercapacitors (SCs). Graphene, a promising two-dimensional material with high conductivity, can be easily processed into papers. Here, we report a rational design of flexible architecture with Co 9 S 8 nanotube arrays (NAs) grown onto graphene paper (GP) via a facile two-step hydrothermal method. When employed as flexible free-standing electrode for SCs, the proposed architectured Co 9 S 8 /GPs exhibits superior electrochemical performance with ultrahigh capacitance and outstanding rate capability (469 F g -1 at 10 A g -1 ). These results demonstrate that the new nanostructured Co 9 S 8 /GPs can be potentially applied in high performance flexible supercapacitors. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. AORN Ergonomic Tool 4: Solutions for Prolonged Standing in Perioperative Settings.

    PubMed

    Hughes, Nancy L; Nelson, Audrey; Matz, Mary W; Lloyd, John

    2011-06-01

    Prolonged standing during surgical procedures poses a high risk of causing musculoskeletal disorders, including back, leg, and foot pain, which can be chronic or acute in nature. Ergonomic Tool 4: Solutions for Prolonged Standing in Perioperative Settings provides recommendations for relieving the strain of prolonged standing, including the use of antifatigue mats, supportive footwear, and sit/stand stools, that are based on well-accepted ergonomic safety concepts, current research, and access to new and emerging technology. Published by Elsevier Inc.

  17. Venous Hemodynamics After Total Hip Arthroplasty: A Comparison Between Portable vs Stationary Pneumatic Compression Devices and the Effect of Body Position.

    PubMed

    Berliner, Jonathan L; Ortiz, Philippe A; Lee, Yuo-Yu; Miller, Theodore T; Westrich, Geoffrey H

    2018-01-01

    Improvements in device design have allowed for portable pneumatic compression devices (PPCDs). However, portability results in smaller pumps that move less blood. Additionally, although patients often stand when wearing PPCDs, few studies have evaluated the hemodynamic effects of PCDs while standing. A crossover study was performed to compare a PPCD (ActiveCare+S.F.T.; Medical Compression Systems, Or Akiva, Israel) to a stationary pneumatic compression device (SPCD) (VenaFlow; DJO Global, Carlsbad, CA) on hemodynamics in supine and standing positions among 2 cohorts composed of 10 controls and 10 total hip arthroplasty patients. Differences in baseline peak venous velocity (PVV), PVV with each PCD, and delta PVV with each PCD were assessed. A multivariate analysis was performed to examine differences between cohorts, devices, and position. In both positions, the SPCD demonstrated a larger change in PVV when compared to the PPCD (P < .001). The total hip arthroplasty group had a greater delta PVV while standing when considering both PCDs together (P < .001). When considering both cohorts, delta PVV was greater while standing, only when the SPCD was used (P < .001). There was no difference between standing and supine positions when the PPCD was used. The SPCD demonstrated a greater capacity to increase PPV in the supine and standing positions. The SPCD generated greater values of PVV and delta PVV in the standing position. Although these results demonstrate a difference between devices, it is important to establish the PVV necessary to prevent VTE before one is considered more effective. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Decoding Lower Limb Muscle Activity and Kinematics from Cortical Neural Spike Trains during Monkey Performing Stand and Squat Movements

    PubMed Central

    Ma, Xuan; Ma, Chaolin; Huang, Jian; Zhang, Peng; Xu, Jiang; He, Jiping

    2017-01-01

    Extensive literatures have shown approaches for decoding upper limb kinematics or muscle activity using multichannel cortical spike recordings toward brain machine interface (BMI) applications. However, similar topics regarding lower limb remain relatively scarce. We previously reported a system for training monkeys to perform visually guided stand and squat tasks. The current study, as a follow-up extension, investigates whether lower limb kinematics and muscle activity characterized by electromyography (EMG) signals during monkey performing stand/squat movements can be accurately decoded from neural spike trains in primary motor cortex (M1). Two monkeys were used in this study. Subdermal intramuscular EMG electrodes were implanted to 8 right leg/thigh muscles. With ample data collected from neurons from a large brain area, we performed a spike triggered average (SpTA) analysis and got a series of density contours which revealed the spatial distributions of different muscle-innervating neurons corresponding to each given muscle. Based on the guidance of these results, we identified the locations optimal for chronic electrode implantation and subsequently carried on chronic neural data recordings. A recursive Bayesian estimation framework was proposed for decoding EMG signals together with kinematics from M1 spike trains. Two specific algorithms were implemented: a standard Kalman filter and an unscented Kalman filter. For the latter one, an artificial neural network was incorporated to deal with the nonlinearity in neural tuning. High correlation coefficient and signal to noise ratio between the predicted and the actual data were achieved for both EMG signals and kinematics on both monkeys. Higher decoding accuracy and faster convergence rate could be achieved with the unscented Kalman filter. These results demonstrate that lower limb EMG signals and kinematics during monkey stand/squat can be accurately decoded from a group of M1 neurons with the proposed algorithms. Our findings provide new insights for extending current BMI design concepts and techniques on upper limbs to lower limb circumstances. Brain controlled exoskeleton, prostheses or neuromuscular electrical stimulators for lower limbs are expected to be developed, which enables the subject to manipulate complex biomechatronic devices with mind in more harmonized manner. PMID:28223914

  19. Effects of Gender, Load, and Backpack on Easy Standing and Vertical Jump Performance. Volume 2

    DTIC Science & Technology

    1982-03-01

    D BY RICHARD C. NELSON AND PHILIP E. MARTIN BIOMECHANICS LABORATORY THE PENNSYLVANIA STATE UNIVERSITY UNIVERSITY PARK, PENNSYLVANIA MARCH...PERFORMING ORGANIZATION NAME AND ADDRESS Biomechanics Laboratory The Pennsylvania State University University Park. Pennsylvania 16802 10. PROGRAM...REFERENCES APPENDICES A. Clothing and Equipment Used in This Study B. ANOVA Summary Tables for Easy Standing C. ANOVA Summary Tables for

  20. Production of Optical Quality Free Standing Diamond Wafer

    DTIC Science & Technology

    2008-05-19

    Title : Production of Optical Quality Free Standing Diamond Wafer Prime Contractor : Onyx Optics, Inc. 6551 Sierra Lane Dublin, Ca 94568...www.onyxoptics.com Program Manager : Helmuth Meissner Onyx Optics, Inc. 6551 Sierra Lane Dublin, CA 94568 Email: hmeissner@onyxoptics.com Ph: 925...PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Onyx Optics, Inc. 6551 Sierra Lane Dublin, Ca 94568 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING

  1. Biological and Economic Productivity of Mixed-Aged Loblolly Pine Stands in the South

    Treesearch

    Ronald Raunikar; Joseph Buongiorno; Jeffrey P. Prestemon; Karen Lee-Abt

    1999-01-01

    The financial performance of the 991 sample plots of uneven-aged loblolly-hardwood stands in the Central South FIA database examined in this report depend crucially on real price trends. Equivalent annual income (EAI) is the measure of economic performance. The regional market stumpage price data are from the Timber Mart-South database. For this set of prices, a...

  2. Standing beat-to-beat blood pressure variability is reduced among fallers in the Malaysian Elders Longitudinal Study.

    PubMed

    Goh, Choon-Hian; Ng, Siew-Cheok; Kamaruzzaman, Shahrul Bahyah; Chin, Ai-Vyrn; Tan, Maw Pin

    2017-10-01

    The aim of this study was to determine the relationship between falls and beat-to-beat blood pressure (BP) variability.Continuous noninvasive BP measurement is as accurate as invasive techniques. We evaluated beat-to-beat supine and standing BP variability (BPV) using time and frequency domain analysis from noninvasive continuous BP recordings.A total of 1218 older adults were selected. Continuous BP recordings obtained were analyzed to determine standard deviation (SD) and root mean square of real variability (RMSRV) for time domain BPV and fast-Fourier transform low frequency (LF), high frequency (HF), total power spectral density (PSD), and LF:HF ratio for frequency domain BPV.Comparisons were performed between 256 (21%) individuals with at least 1 fall in the past 12 months and nonfallers. Fallers were significantly older (P = .007), more likely to be female (P = .006), and required a longer time to complete the Timed-Up and Go test (TUG) and frailty walk test (P ≤ .001). Standing systolic BPV (SBPV) was significantly lower in fallers compared to nonfallers (SBPV-SD, P = .016; SBPV-RMSRV, P = .033; SBPV-LF, P = .003; SBPV-total PSD, P = .012). Nonfallers had significantly higher supine to standing ratio (SSR) for SBPV-SD, SBPV-RMSRV, and SBPV-total PSD (P = .017, P = .013, and P = .009). In multivariate analyses, standing BPV remained significantly lower in fallers compared to nonfallers after adjustment for age, sex, diabetes, frailty walk, and supine systolic BP. The reduction in frequency-domain SSR among fallers was attenuated by supine systolic BP, TUG, and frailty walk.In conclusion, reduced beat-to-beat BPV while standing is independently associated with increased risk of falls. Changes between supine and standing BPV are confounded by supine BP and walking speed.

  3. Repeated Stand-Replacing Crown Fires Affect Seed Morphology and Germination in Aleppo pine

    PubMed Central

    Saracino, Antonio; Bellino, Alessandro; Allevato, Emilia; Mingo, Antonio; Conti, Stefano; Rossi, Sergio; Bonanomi, Giuliano; Carputo, Domenico; Mazzoleni, Stefano

    2017-01-01

    Post-fire reproductive niche of Aleppo pine (Pinus halepensis) is deeply interlaced with fire products. Indeed, the high pH and low osmotic potentials of ash beds under burnt crowns constitute the main constraints to seed germination. In this study, we aim to investigate whether fire recurrence, through the physico-chemical constraints imposed by the ash beds, affects the reproduction ability of P. halepensis at the germination stage. To this aim, Aleppo pine seeds were collected in neighboring even-aged stands subjected to 0, 1, or 2 fires (namely fire cohorts), and seed morphology and germination performance, in terms of cumulative germination and germination kinetics, were studied under increasing osmotic potentials (from 0.0 to −1.2 MPa) and pH (from 6 to 11). Besides fire history, the role of ontogenetic age of mother plants on seed morphology and germination was also investigated. Differences in seed morphology among the three cohorts have been highlighted in a multivariate context, with anisotropic enlargement of the seeds produced by pine stands experiencing repeated fires. The patterns of seed germination varied primarily in relation to the fire cohort, with seeds from the pine stand experiencing repeated fires exhibiting enhanced tolerance to pH stress. Conversely, germination performances under osmotic constraints mainly depends on tree ontogenetic stage, with an involvement of fire history especially in the timing of seed germination. Our results suggest that, at least in the short term, fire recurrence does not constrain the reproduction ability of Aleppo pine. These results highlight the need for further research to elucidate the mechanisms behind these responses to recurrent fires. PMID:28713415

  4. Validation of Cardiovascular Parameters during NASA's Functional Task Test

    NASA Technical Reports Server (NTRS)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2009-01-01

    Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p<0.006) than inter-session variability (p>0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight rest and stand values. Postflight HRV showed higher LF/HF for rest and stand and lower HFnu during rest. CONCLUSION: These studies show that a 3 min stand delivers repeatable HRV data in the context of this larger series of FTT tests. Spaceflight-induced changes in blood pressure, RR and autonomic function (HRV) are evident from the RFST.

  5. Sensor Fusion to Infer Locations of Standing and Reaching Within the Home in Incomplete Spinal Cord Injury.

    PubMed

    Lonini, Luca; Reissman, Timothy; Ochoa, Jose M; Mummidisetty, Chaithanya K; Kording, Konrad; Jayaraman, Arun

    2017-10-01

    The objective of rehabilitation after spinal cord injury is to enable successful function in everyday life and independence at home. Clinical tests can assess whether patients are able to execute functional movements but are limited in assessing such information at home. A prototype system is developed that detects stand-to-reach activities, a movement with important functional implications, at multiple locations within a mock kitchen. Ten individuals with incomplete spinal cord injuries performed a sequence of standing and reaching tasks. The system monitored their movements by combining two sources of information: a triaxial accelerometer, placed on the subject's thigh, detected sitting or standing, and a network of radio frequency tags, wirelessly connected to a wrist-worn device, detected reaching at three locations. A threshold-based algorithm detected execution of the combined tasks and accuracy was measured by the number of correctly identified events. The system was shown to have an average accuracy of 98% for inferring when individuals performed stand-to-reach activities at each tag location within the same room. The combination of accelerometry and tags yielded accurate assessments of functional stand-to-reach activities within a home environment. Optimization of this technology could simplify patient compliance and allow clinicians to assess functional home activities.

  6. Effect of Postural Control Demands on Early Visual Evoked Potentials during a Subjective Visual Vertical Perception Task in Adolescents with Idiopathic Scoliosis.

    PubMed

    Chang, Yi-Tzu; Meng, Ling-Fu; Chang, Chun-Ju; Lai, Po-Liang; Lung, Chi-Wen; Chern, Jen-Suh

    2017-01-01

    Subjective visual vertical (SVV) judgment and standing stability were separately investigated among patients with adolescent idiopathic scoliosis (AIS). Although, one study has investigated the central mechanism of stability control in the AIS population, the relationships between SVV, decreased standing stability, and AIS have never been investigated. Through event-related potentials (ERPs), the present study examined the effect of postural control demands (PDs) on AIS central mechanisms related to SVV judgment and standing stability to elucidate the time-serial stability control process. Thirteen AIS subjects (AIS group) and 13 age-matched adolescents (control group) aged 12-18 years were recruited. Each subject had to complete an SVV task (i.e., the modified rod-and-frame [mRAF] test) as a stimulus, with online electroencephalogram recording being performed in the following three standing postures: feet shoulder-width apart standing, feet together standing, and tandem standing. The behavioral performance in terms of postural stability (center of pressure excursion), SVV (accuracy and reaction time), and mRAF-locked ERPs (mean amplitude and peak latency of the P1, N1, and P2 components) was then compared between the AIS and control groups. In the behavioral domain, the results revealed that only the AIS group demonstrated a significantly accelerated SVV reaction time as the PDs increased. In the cerebral domain, significantly larger P2 mean amplitudes were observed during both feet shoulder-width-apart standing and feet together standing postures compared with during tandem standing. No group differences were noted in the cerebral domain. The results indicated that (1) during the dual-task paradigm, a differential behavioral strategy of accelerated SVV reaction time was observed in the AIS group only when the PDs increased and (2) the decrease in P2 mean amplitudes with the increase in the PD levels might be direct evidence of the competition for central processing attentional resources under the dual-task postural control paradigm.

  7. Relationship between movement time and hip moment impulse in the sagittal plane during sit-to-stand movement: a combined experimental and computer simulation study.

    PubMed

    Inai, Takuma; Takabayashi, Tomoya; Edama, Mutsuaki; Kubo, Masayoshi

    2018-04-27

    The association between repetitive hip moment impulse and the progression of hip osteoarthritis is a recently recognized area of study. A sit-to-stand movement is essential for daily life and requires hip extension moment. Although a change in the sit-to-stand movement time may influence the hip moment impulse in the sagittal plane, this effect has not been examined. The purpose of this study was to clarify the relationship between sit-to-stand movement time and hip moment impulse in the sagittal plane. Twenty subjects performed the sit-to-stand movement at a self-selected natural speed. The hip, knee, and ankle joint angles obtained from experimental trials were used to perform two computer simulations. In the first simulation, the actual sit-to-stand movement time obtained from the experiment was entered. In the second simulation, sit-to-stand movement times ranging from 0.5 to 4.0 s at intervals of 0.25 s were entered. Hip joint moments and hip moment impulses in the sagittal plane during sit-to-stand movements were calculated for both computer simulations. The reliability of the simulation model was confirmed, as indicated by the similarities in the hip joint moment waveforms (r = 0.99) and the hip moment impulses in the sagittal plane between the first computer simulation and the experiment. In the second computer simulation, the hip moment impulse in the sagittal plane decreased with a decrease in the sit-to-stand movement time, although the peak hip extension moment increased with a decrease in the movement time. These findings clarify the association between the sit-to-stand movement time and hip moment impulse in the sagittal plane and may contribute to the prevention of the progression of hip osteoarthritis.

  8. Effect of Postural Control Demands on Early Visual Evoked Potentials during a Subjective Visual Vertical Perception Task in Adolescents with Idiopathic Scoliosis

    PubMed Central

    Chang, Yi-Tzu; Meng, Ling-Fu; Chang, Chun-Ju; Lai, Po-Liang; Lung, Chi-Wen; Chern, Jen-Suh

    2017-01-01

    Subjective visual vertical (SVV) judgment and standing stability were separately investigated among patients with adolescent idiopathic scoliosis (AIS). Although, one study has investigated the central mechanism of stability control in the AIS population, the relationships between SVV, decreased standing stability, and AIS have never been investigated. Through event-related potentials (ERPs), the present study examined the effect of postural control demands (PDs) on AIS central mechanisms related to SVV judgment and standing stability to elucidate the time-serial stability control process. Thirteen AIS subjects (AIS group) and 13 age-matched adolescents (control group) aged 12–18 years were recruited. Each subject had to complete an SVV task (i.e., the modified rod-and-frame [mRAF] test) as a stimulus, with online electroencephalogram recording being performed in the following three standing postures: feet shoulder-width apart standing, feet together standing, and tandem standing. The behavioral performance in terms of postural stability (center of pressure excursion), SVV (accuracy and reaction time), and mRAF-locked ERPs (mean amplitude and peak latency of the P1, N1, and P2 components) was then compared between the AIS and control groups. In the behavioral domain, the results revealed that only the AIS group demonstrated a significantly accelerated SVV reaction time as the PDs increased. In the cerebral domain, significantly larger P2 mean amplitudes were observed during both feet shoulder-width-apart standing and feet together standing postures compared with during tandem standing. No group differences were noted in the cerebral domain. The results indicated that (1) during the dual-task paradigm, a differential behavioral strategy of accelerated SVV reaction time was observed in the AIS group only when the PDs increased and (2) the decrease in P2 mean amplitudes with the increase in the PD levels might be direct evidence of the competition for central processing attentional resources under the dual-task postural control paradigm. PMID:28713252

  9. The Effectiveness of Standing on a Balance Board for Increasing Energy Expenditure.

    PubMed

    Nelson, Megan C; Casanova, Madeline P; Vella, Chantal A

    2018-03-01

    To investigate differences in energy expenditure (EE), heart rate (HR), productivity, fatigue, and pain while performing desk work while sitting (SIT), standing (STAND), and standing on a balance board (BOARD). Thirty healthy adults (60% female; age 39.7 ± 11.8 y; BMI 26.7 ± 5.0 kg·m) employed in sedentary-based jobs volunteered for this randomized crossover trial. Participants performed typing work in three different positions: SIT, STAND, and BOARD; each condition lasting 30 min. Oxygen consumption (VO2) was measured via indirect calorimetry and EE was calculated using respiratory quotient and corresponding caloric equivalent values. Productivity was quantified by measuring words typed per min, accuracy, and typing mistakes. Overall feelings of fatigue and pain were self-reported three times during each position using validated 10-cm visual analog scales. Repeated measures ANOVA were used to assess differences in outcome variables across conditions. VO2 was significantly different among all conditions regardless of current standing desk use (SIT 3.35 ± 0.53; STAND 3.77 ± 0.48; BOARD 3.92 ± 0.54 mL·kg·min, p<0.001). EE (kcal·min) also differed (p<0.001) among SIT (1.27 ± 0.22), STAND (1.42 ± 0.26) and BOARD (1.48 ± 0.29). Compared to sitting (67 ± 9 bpm), HR was higher in STAND (76 ± 11 bpm) and BOARD (76 ± 11 bpm, p<0.001). Measures of productivity were not different across conditions (p>0.05). Fatigue progressively increased over each 30 min condition whereas pain in SIT and BOARD increased from min 10 to 20, then leveled off between min 20 to 30. For STAND, pain continued to increase over time. Compared with sitting, a balance board may be effective for increasing EE without interfering with productivity in an occupational setting.

  10. Analytic method for material aging and quality analyzing to forecast long time stability of plastic micro heliostat components

    NASA Astrophysics Data System (ADS)

    Sauerborn, Markus; Liebenstund, Lena; Raue, Markus; Mang, Thomas; Herrmann, Ulf; Dueing, Andreas

    2017-06-01

    The Solar-Institute Jülich (SIJ) developed the micro heliostat system - a small sized heliostat - during the last years. One special performance of the micro heliostat is the option to integrate inexpensive plastic elements. The use of plastic as a cost reducer in the heliostat technique is also offering the chance to integrate complex designed components with a higher quality and special system function. The plastic for this application requires a high standing against UV radiation and thermal cycles with a daily extreme temperature variation. The temperature range inside the closed micro heliostat box can annually fluctuate between -20 °C and 80 °C in the worst case. Special aging tests were designed and performed for the first time in cooperation with the Institute for Applied Polymer Science (IAP) in order to identify and qualify a resistance plastic for the micro heliostat. This systematic plastic aging testing for the micro heliostat is introduced here. The tests were carried out under extreme ambient situations, which simulate the temperature and irradiation conditions that the heliostat has to stand for years. A particular climate of arid areas with continuous high solar radiation was defined for these tests. Two accelerating aging methods were adapted to reach adequate aging results in a reduced time. The aging of the investigated kinds of plastics were followed by tensile test, impact test, measuring Shore hardness, dynamic-mechanical analysis, differential scanning calorimetry and Fourier transform infrared spectroscopy to compare the different types of polymers. Parallel to these tests running real outdoor tests were performed, to control this accelerated aging. To have adequate conditions that the plastic in a micro heliostat has to stand, an identical closed test box with a glass cover was designed. The test samples inside the box were irradiated by the sun. The wanted forecast for the analyzed plastic was defined by the comparison of the real and the accelerated aging results.

  11. Hidden marker position estimation during sit-to-stand with walker.

    PubMed

    Yoon, Sang Ho; Jun, Hong Gul; Dan, Byung Ju; Jo, Byeong Rim; Min, Byung Hoon

    2012-01-01

    Motion capture analysis of sit-to-stand task with assistive device is hard to achieve due to obstruction on reflective makers. Previously developed robotic system, Smart Mobile Walker, is used as an assistive device to perform motion capture analysis in sit-to-stand task. All lower limb markers except hip markers are invisible through whole session. The link-segment and regression method is applied to estimate the marker position during sit-to-stand. Applying a new method, the lost marker positions are restored and the biomechanical evaluation of the sit-to-stand movement with a Smart Mobile Walker could be carried out. The accuracy of the marker position estimation is verified with normal sit-to-stand data from more than 30 clinical trials. Moreover, further research on improving the link segment and regression method is addressed.

  12. A test of high-dose verbenone for stand-level protection of lodgepole and whitebark pine from mountain pine beetle (Coleoptera: Curculionidae: Scolytinae) attacks

    Treesearch

    B. J. Bentz; S. Kegley; K. Gibson; R. Their

    2005-01-01

    The effcacy of verbenone as a stand-level protectant against mountain pine beetle, Dendroctonus ponderosae Hopkins, attacks was tested in lodgepole and whitebark pine stands at five geographically separated sites, including three consecutive years at one site. Forty and 20 high-dose pouches, with a verbenone emission rate up to 50 mg/d per pouch, were spaced in a grid...

  13. Associations of Walking Speed, Grip Strength, and Standing Balance With Total and Cause-Specific Mortality in a General Population of Japanese Elders.

    PubMed

    Nofuji, Yu; Shinkai, Shoji; Taniguchi, Yu; Amano, Hidenori; Nishi, Mariko; Murayama, Hiroshi; Fujiwara, Yoshinori; Suzuki, Takao

    2016-02-01

    Walking speed, grip strength, and standing balance are key components of physical performance in older people. The present study aimed to evaluate (1) associations of these physical performance measures with cause-specific mortality, (2) independent associations of individual physical performance measures with mortality, and (3) the added value of combined use of the 3 physical performance measures in predicting all-cause and cause-specific mortality. Prospective cohort study with a follow-up of 10.5 years. Tokyo Metropolitan Institute of Gerontology Longitudinal Interdisciplinary Study on Aging (TMIG-LISA), Japan. A total of 1085 initially nondisabled older Japanese aged 65 to 89 years. Usual walking speed, grip strength, and standing balance were measured at baseline survey. During follow-up, 324 deaths occurred (122 of cardiovascular disease, 75 of cancer, 115 of other causes, and 12 of unknown causes). All 3 physical performance measures were significantly associated with all-cause, cardiovascular, and other-cause mortality, but not with cancer mortality, independent of potential confounders. When all 3 physical performance measures were simultaneously entered into the model, each was significantly independently associated with all-cause and cardiovascular mortality. The C statistics for all-cause and cardiovascular mortality were significantly increased by adding grip strength and standing balance to walking speed (P < .01), and the net reclassification improvement for them was estimated at 18.7% and 7.5%, respectively. Slow walking speed, weak grip strength, and poor standing balance predicted all-cause, cardiovascular, and other-cause mortality, but not cancer mortality, independent of covariates. Moreover, these 3 components of physical performance were independently associated with all-cause and cardiovascular mortality and their combined use increased prognostic power. Copyright © 2016 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  14. Three-dimensional instability of standing waves

    NASA Astrophysics Data System (ADS)

    Zhu, Qiang; Liu, Yuming; Yue, Dick K. P.

    2003-12-01

    We investigate the three-dimensional instability of finite-amplitude standing surface waves under the influence of gravity. The analysis employs the transition matrix (TM) approach and uses a new high-order spectral element (HOSE) method for computation of the nonlinear wave dynamics. HOSE is an extension of the original high-order spectral method (HOS) wherein nonlinear wave wave and wave body interactions are retained up to high order in wave steepness. Instead of global basis functions in HOS, however, HOSE employs spectral elements to allow for complex free-surface geometries and surface-piercing bodies. Exponential convergence of HOS with respect to the total number of spectral modes (for a fixed number of elements) and interaction order is retained in HOSE. In this study, we use TM-HOSE to obtain the stability of general three-dimensional perturbations (on a two-dimensional surface) on two classes of standing waves: plane standing waves in a rectangular tank; and radial/azimuthal standing waves in a circular basin. For plane standing waves, we confirm the known result of two-dimensional side-bandlike instability. In addition, we find a novel three-dimensional instability for base flow of any amplitude. The dominant component of the unstable disturbance is an oblique (standing) wave oriented at an arbitrary angle whose frequency is close to the (nonlinear) frequency of the original standing wave. This finding is confirmed by direct long-time simulations using HOSE which show that the nonlinear evolution leads to classical Fermi Pasta Ulam recurrence. For the circular basin, we find that, beyond a threshold wave steepness, a standing wave (of nonlinear frequency Omega) is unstable to three-dimensional perturbations. The unstable perturbation contains two dominant (standing-wave) components, the sum of whose frequencies is close to 2Omega. From the cases we consider, the critical wave steepness is found to generally decrease/increase with increasing radial/azimuthal mode number of the base standing wave. Finally, we show that the instability we find for both two- and three-dimensional standing waves is a result of third-order (quartet) resonance.

  15. Effects of bilateral swing-away grab bars on the biomechanics of stand-to-sit and sit-to-stand toilet transfers.

    PubMed

    Lee, Su Jin; Mehta-Desai, Ricky; Oh, Kyunggeune; Sanford, Jon; Prilutsky, Boris I

    2018-03-09

    Kinetic characteristics of transfers to and from a toilet performed using bilateral grab bars are not fully quantified to inform grab bar design and configuration. The purpose of this study was to (1) determine effects of bilateral swing-away grab bars on peaks of ankle, knee and hip joint moments during grab bar assisted stand-to-sit and sit-to-stand transfers; and (2) determine effects of three different heights and widths of swing-away grab bars on the same kinetic characteristics. Healthy subjects (N = 11, age 25-58 years) performed stand-to-sit and sit-to-stand transfers with and without grab bars. In transfers with grab bars, 9 grab bar configurations were tested by varying their height from the floor (0.787 m, 0.813 m, 0.838 m; 31″-33″) and width, the distance of each grab bar from the toilet's centerline (0.330 m, 0.356 m, 0.381 m; 13″-15″). Motion capture, force plate and inverse dynamics analysis were used to determine lower limb joint moments. The use of bilateral grab bars generally reduced the peak magnitude of extension moments at lower limb joints during stand-to-sit and sit-to-stand transfers (p < .05), except the ankle joint moments during stand-to-sit transfers. Relatively few differences in peak joint moments were found between studied grab bar widths or heights. The obtained results suggest that the studied ranges of grab bar configurations reduce moment demands on the leg joints and thus decrease difficulty and required lower limb muscle effort to perform the transfers. Implications for Rehabilitation Maximizing the benefits of assistive technology in the built environment requires a careful assessment of their spatial and configurational dimensions, especially in respect to the needs and abilities of the intended users. Examining the kinetic characteristics of transfers to and from a toilet using the swing-away grab bars is useful for informing grab bar design and configuration recommendations for assisted living and skilled nursing facilities. Our findings suggest that the swing-away grab bars located at certain ranges are a reasonable alternative to the grab bars mandated by the current Americans with Disabilities Act (ADA) Accessibility Guidelines. Future research investigating the effects of grab bars on transfer performance should consider additional factors, such as a wider range of abilities and transfer methods of the users.

  16. Study of the human postural control system during quiet standing using detrended fluctuation analysis

    NASA Astrophysics Data System (ADS)

    Teresa Blázquez, M.; Anguiano, Marta; de Saavedra, Fernando Arias; Lallena, Antonio M.; Carpena, Pedro

    2009-05-01

    The detrended fluctuation analysis is used to study the behavior of different time series obtained from the trajectory of the center of pressure, the output of the activity of the human postural control system. The results suggest that these trajectories present two different regimes in their scaling properties: persistent (for high frequencies, short-range time scale) to antipersistent (for low frequencies, long-range time scale) behaviors. The similitude between the results obtained for the measurements, done with both eyes open and eyes closed, indicate either that the visual system may be disregarded by the postural control system while maintaining the quiet standing, or that the control mechanisms associated with each type of information (visual, vestibular and somatosensory) cannot be disentangled with the type of analysis performed here.

  17. Constructing Free Standing Metal Organic Framework MIL-53 Membrane Based on Anodized Aluminum Oxide Precursor

    PubMed Central

    Zhang, Yunlu; Gao, Qiuming; Lin, Zhi; Zhang, Tao; Xu, Jiandong; Tan, Yanli; Tian, Weiqian; Jiang, Lei

    2014-01-01

    Metal organic framework (MOF) materials have attracted great attention due to their well-ordered and controllable pores possessing of prominent potentials for gas molecule sorption and separation performances. Organizing the MOF crystals to a continuous membrane with a certain scale will better exhibit their prominent potentials. Reports in recent years concentrate on well grown MOF membranes on specific substrates. Free standing MOF membranes could have more important applications since they are independent from the substrates. However, the method to prepare such a membrane has been a great challenge because good mechanical properties and stabilities are highly required. Here, we demonstrate a novel and facile technique for preparing the free standing membrane with a size as large as centimeter scale. The substrate we use proved itself not only a good skeleton but also an excellent precursor to fulfill the reaction. This kind of membrane owns a strong mechanical strength, based on the fact that it is much thinner than the composite membranes grown on substrates and it could exhibit good property of gas separation. PMID:24821299

  18. Targeted sequencing-based analyses of candidate gene variants in ulcerative colitis-associated colorectal neoplasia.

    PubMed

    Chakrabarty, Sanjiban; Varghese, Vinay Koshy; Sahu, Pranoy; Jayaram, Pradyumna; Shivakumar, Bhadravathi M; Pai, Cannanore Ganesh; Satyamoorthy, Kapaettu

    2017-06-27

    Long-standing ulcerative colitis (UC) leading to colorectal cancer (CRC) is one of the most serious and life-threatening consequences acknowledged globally. Ulcerative colitis-associated colorectal carcinogenesis showed distinct molecular alterations when compared with sporadic colorectal carcinoma. Targeted sequencing of 409 genes in tissue samples of 18 long-standing UC subjects at high risk of colorectal carcinoma (UCHR) was performed to identify somatic driver mutations, which may be involved in the molecular changes during the transformation of non-dysplastic mucosa to high-grade dysplasia. Findings from the study are also compared with previously published genome wide and exome sequencing data in inflammatory bowel disease-associated and sporadic colorectal carcinoma. Next-generation sequencing analysis identified 1107 mutations in 275 genes in UCHR subjects. In addition to TP53 (17%) and KRAS (22%) mutations, recurrent mutations in APC (33%), ACVR2A (61%), ARID1A (44%), RAF1 (39%) and MTOR (61%) were observed in UCHR subjects. In addition, APC, FGFR3, FGFR2 and PIK3CA driver mutations were identified in UCHR subjects. Recurrent mutations in ARID1A (44%), SMARCA4 (17%), MLL2 (44%), MLL3 (67%), SETD2 (17%) and TET2 (50%) genes involved in histone modification and chromatin remodelling were identified in UCHR subjects. Our study identifies new oncogenic driver mutations which may be involved in the transition of non-dysplastic cells to dysplastic phenotype in the subjects with long-standing UC with high risk of progression into colorectal neoplasia.

  19. Prototyping high-gradient mm-wave accelerating structures

    DOE PAGES

    Nanni, Emilio A.; Dolgashev, Valery A.; Haase, Andrew; ...

    2017-01-01

    We present single-cell accelerating structures designed for high-gradient testing at 110 GHz. The purpose of this work is to study the basic physics of ultrahigh vacuum RF breakdown in high-gradient RF accelerators. The accelerating structures are π-mode standing-wave cavities fed with a TM 01 circular waveguide. The structures are fabricated using precision milling out of two metal blocks, and the blocks are joined with diffusion bonding and brazing. The impact of fabrication and joining techniques on the cell geometry and RF performance will be discussed. First prototypes had a measured Q 0 of 2800, approaching the theoretical design value ofmore » 3300. The geometry of these accelerating structures are as close as practical to singlecell standing-wave X-band accelerating structures more than 40 of which were tested at SLAC. This wealth of X-band data will serve as a baseline for these 110 GHz tests. Furthermore, the structures will be powered with short pulses from a MW gyrotron oscillator. RF power of 1 MW may allow an accelerating gradient of 400 MeV/m to be reached.« less

  20. Freestanding polyaniline nanorods grown on graphene for highly capacitive energy storage

    NASA Astrophysics Data System (ADS)

    Li, Zijiong; Qin, Zhen; Yang, Baocheng; Guo, Jian; Wang, Haiyan; Zhang, Weiyang; Lv, Xiaowei; Stack, Alison

    2015-02-01

    Freestanding polyaniline (PANI) nanorods grown in situ on microwave-expanded graphene oxide (MEGO) sheets were prepared through a facile solution method. The morphological characterization indicates that large quantity of free-standing PANI nanorods with average diameter of 50 nm were uniformly deposited onto the double sides of the MEGO nanosheets to form a sandwich structure. The hybrid of PANI/MEGO (GPANI) exhibit high specific surface area and high electrical conductivity, compared with pristine PANI nanorods. When evaluated as electrodes for supercapacitors, the GPANI demonstrate high specific capacitance of 628 F g-1 at a current density of 1.1 A g-1, high-rate performance, and excellent cycle stability compared to individual component. Such excellent electrochemical performance should be attributed to the combined double-layer capacitance and pseudo -capacitance mechanisms from the MEGO sheets and PANI nanorods.

  1. Habitat fragmentation leads to reduced pollinator visitation, fruit production and recruitment in urban mangrove forests.

    PubMed

    Hermansen, Tyge D; Minchinton, Todd E; Ayre, David J

    2017-10-01

    Mangrove forests worldwide undergo anthropogenic fragmentation that may threaten their existence, and yet there have been few tests of the effects of fragmentation on demographic processes critical for mangrove regeneration. Predicting the effects of habitat fragmentation on mangroves is problematic as pollinators may move more freely across water than terrestrial habitat, and propagules can be widely dispersed by water. Here, within each of two estuaries, we compared pollinator diversity and activity, reproductive effort and output, and rates of recruitment for sets of three large (>1500 trees), medium (300-500) and small (<50) stands. As predicted, most measures of reproductive activity and success were inversely related to stand size with large stands typically producing significantly more and larger fruit, and significantly more seedlings. Most strikingly, we found the effect of fragmentation on the abundance of pollinators (honeybees), the production and quality of fruit and the survival rate of seedlings to be similar, showing significant reduction of recruitment in small stands. This study provides the first rigorous evidence that recruitment of mangroves, like for many terrestrial plants, is negatively impacted by habitat fragmentation. From a management perspective, we argue that in the short term our data imply the importance of conserving the largest possible stands. However, additional work is needed to determine (1) the proportion of recruits within small stands that originate within large stands, (2) how seedling performance varies with fruit size and genotype, and (3) how seedling size and performance vary with the abundance and diversity of pollen.

  2. Potential method for relieving fatigue in radiologists

    NASA Astrophysics Data System (ADS)

    Krupinski, Elizabeth A.

    2013-03-01

    Radiologists moved to an environment in which they read digital images off of computer displays instead of film images off of light boxes. With film and light boxes they typically would read for about an hour (seated) and then take a break while the film librarian changed the images on the view box. With digital viewing off computers they tend to sit all day in front of the computers with far fewer breaks and opportunity to stand up and move around than with film. There is concern that this lack of activity not only contributes to back, shoulder and neck discomfort, but also contributes to increased fatigue which has been shown to impact reader performance. The goal of this study was to determine if there are differences in physiologic vital signs (heart rate and blood pressure) of radiologists as a function of whether they read images while seated or while standing up. Five subjects had their blood pressure and heart rate measured while seated and while standing reading cases in the normal clinical setting. For all three measures there was a statistically significant (p < 0.0001) difference between seated and standing measures with seated being lower than standing. The higher heart rate and blood pressure with standing suggests that the radiologists are more active in this position and thus potentially more attentive than while seated. This study will be followed up to determine impact on diagnostic performance of standing vs seated as well as subjective ratings of wakefulness and mood.

  3. Free-standing, well-aligned ordered mesoporous carbon nanofibers on current collectors for high-power micro-supercapacitors.

    PubMed

    Kang, Eunae; Jeon, Gumhye; Kim, Jin Kon

    2013-07-21

    The mesoporous carbon nanofiber arrays that stand on carbon-gold double-layer current collectors are synthesized by self-assembly of a PS-b-PEO copolymer and resol in AAO templates for a high-power micro-supercapacitor at high current densities.

  4. Free-standing three-dimensional graphene/manganese oxide hybrids as binder-free electrode materials for energy storage applications.

    PubMed

    Zhu, Xiaoli; Zhang, Peng; Xu, Shan; Yan, Xingbin; Xue, Qunji

    2014-07-23

    Novel three-dimensional (3D) hybrid materials, i.e., free-standing 3D graphene-supported MnO2 nanosheets, are prepared by a simple and controllable solution-phase assembly process. Characterization results show that MnO2 nanosheets are uniformly anchored on a 3D graphene framework with strong adhesion and the integral hybrids show desirable mechanical strength. Such unique structure of 3D graphene/MnO2 hybrids thus provides the right characteristics of binder-free electrode materials and could enable the design of different kinds of high-performance energy storage devices. Especially, an advanced asymmetric supercapacitor is built by using a 3D graphene/MnO2 hybrid and a 3D graphene as two electrodes, and it is able to work reversibly in a full operation voltage region of 0-3.5 V in an ionic liquid electrolyte and thus exhibits a high energy density of 68.4 Wh/kg. As the cathode materials for Li-O2 and Li-MnO2 batteries, the 3D graphene/MnO2 hybrids exhibit outstanding performances, including good catalytic capability, high reversible capacity and desirable cycling stability. The results presented here may pave a way for new promising applications of such 3D graphene/MnO2 hybrids in advanced electrochemical energy storage devices.

  5. Self-standing gel polymer electrolyte for improving supercapacitor thermal and electrochemical stability

    NASA Astrophysics Data System (ADS)

    Dagousset, Laure; Pognon, Grégory; Nguyen, Giao T. M.; Vidal, Frédéric; Jus, Sébastien; Aubert, Pierre-Henri

    2018-07-01

    Electrochemical energy storage is a very active research topic. However, the use of liquid electrolyte in such systems as supercacitors presents several drawbacks on security and packaging. One way to overcome these issues is to design supercapacitors using solid-state electrolytes. We report here the one-pot synthesis and the characterization of self-standing gel polymer electrolyte (SGPE) composed of semi-Interpenetrating Polymer Networks (semi-IPN) based on poly(ethylene oxide) (PEO) network and non cross-linked nitrile butadiene rubber (NBR), self-containing EMITFSI/γ-Butyrolactone (50/50 wt%/wt%) binary mixtures. The SGPE under the form of a thin film are then used as solid electrolyte and also as separator in supercapacitors with Single Wall Carbon Nanotubes (SWCNTs) bucky paper as electrodes. Thermal characterization revealed the suitability of all synthesized membrane in wide range of operating temperature. Electrochemical stabilities of SGPE were close to that of a cellulose separator system (ESW∼3.2-3.6 V) at 20 °C, and were relatively higher than a cellulose system at 100 °C: 2.1-2.5 V and 1.8 V respectively. Furthermore, floating experiments at 100 °C (holding voltage at 2 V) revealed the exceptionally high stability of SGPE, with a residual capacitance of 93% after 500 h. This high electrochemical performance demonstrated the potential of semi-IPN SGPE as separator/electrolyte for high performance supercapacitors.

  6. Orthostatic responses at 4860 m in low, moderate, and high altitude residents.

    PubMed

    Davis, John E; Wagner, Dale R; Thorington, Jessica; Schall, Cory

    2013-09-01

    This study evaluated the influence of altitude of residence on orthostatic responses when exposed to high altitude. Data collection took place at the Carrel hut (4860 m) on Chimborazo in Ecuador. After being transported to the hut by vehicle, 69 people volunteered for the study. A 3-min stand test (rapid change from supine to standing) provided an orthostatic challenge while resting heart rate (RHR), systolic (SBP) and diastolic (DBP) blood pressures, and arterial oxygen saturation (SpO2) were measured. Participants were separated into four groups based on altitude of residence and ethnicity: LOW (<1500 m; n=15), MOD (1500-3000 m, n=30), and HIGH (>3000 m, n=11) Ecuadorians, and non-Ecuadorian lowlanders (NE-LOW, n=13). Supine and standing RHRs were lower (p<0.05) for HIGH compared to other groups. Furthermore, standing increased RHR in LOW, MOD, and NE-LOW by 11.9 ± 5.3, 9.5 ± 4.1, and 11.6 ± 7.4 bpm, respectively, while HIGH stayed the same (0.6 bpm increase ± 3.3). Additionally, mean arterial pressure decreased slightly but not significantly upon standing in all groups except HIGH. The difference in Spo2 among groups was not significant (p>0.05). Altitude of residence influences the cardiovascular responses to orthostatic stress with HIGH having blunted responses and greater tolerance.

  7. A new standing posture detector to enable people with multiple disabilities to control environmental stimulation by changing their standing posture through a commercial Wii Balance Board.

    PubMed

    Shih, Ching-Hsiang; Shih, Ching-Tien; Chiang, Ming-Shan

    2010-01-01

    This study assessed whether two persons with multiple disabilities would be able to control environmental stimulation using body swing (changing standing posture) and a Wii Balance Board with a newly developed standing posture detection program (i.e. a new software program turns a Wii Balance Board into a precise standing posture detector). The study was performed according to an ABAB design, in which A represented baseline and B represented intervention phases. Both participants significantly increased their target response (body swing) to activate the control system to produce environmental stimulation during the intervention phases. Practical and developmental implications of the findings were discussed.

  8. A rationally designed composite of alternating strata of Si nanoparticles and graphene: a high-performance lithium-ion battery anode.

    PubMed

    Sun, Fu; Huang, Kai; Qi, Xiang; Gao, Tian; Liu, Yuping; Zou, Xianghua; Wei, Xiaolin; Zhong, Jianxin

    2013-09-21

    We have successfully fabricated a free-standing Si-re-G (reduced graphene) alternating stratum structure composite through a repeated process of filtering liquid exfoliated graphene oxide and uniformly dispersed Si solution, followed by the reduction of graphene oxide. The as-prepared free-standing flexible alternating stratum structure composite was directly evaluated as the anode for rechargeable lithium half-cells without adding any polymer binder, conductive additives or using current collectors. The half cells based on this new alternating structure composite exhibit an unexpected capacity of 1500 mA h g(-1) after 100 cycles at 1.35 A g(-1). Our rationally proposed strategy has incorporated the long cycle life of carbon and the high lithium-storage capacity of Si into one entity using the feasible and scalable vacuum filtration technique, rendering this new protocol as a readily applicable means of addressing the practical application challenges associated with the next generation of rechargeable lithium-ion batteries.

  9. Flexible phosphorus doped carbon nanosheets/nanofibers: Electrospun preparation and enhanced Li-storage properties as free-standing anodes for lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Li, Desheng; Wang, Dongya; Rui, Kun; Ma, Zhongyuan; Xie, Ling; Liu, Jinhua; Zhang, Yu; Chen, Runfeng; Yan, Yan; Lin, Huijuan; Xie, Xiaoji; Zhu, Jixin; Huang, Wei

    2018-04-01

    The emerging wearable and foldable electronic devices drive the development of flexible lithium ion batteries (LIBs). Carbon materials are considered as one of the most promising electrode materials for LIBs due to their light weight, low cost and good structural stability against repeated deformations. However, the specific capacity, rate capability and long-term cycling performance still need to be improved for their applications in next-generation LIBs. Herein, we report a facile approach for immobilizing phosphorus into a large-area carbon nanosheets/nanofibers interwoven free-standing paper for LIBs. As an anode material for LIBs, it shows high reversible capacity of 1100 mAh g-1 at a current density of 200 mA g-1, excellent rate capabilities (e.g., 200 mAh g-1 at 20,000 mA g-1). Even at a high current density of 1000 mA g-1, it still maintains a superior specific capacity of 607 mAh g-1 without obvious decay.

  10. Testing Single Phase IGBT H-Bridge Switch Plates for the High Voltage Converter Modulator at the Spallation Neutron Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peplov, Vladimir V; Anderson, David E; Solley, Dennis J

    2014-01-01

    Three IGBT H-bridge switching networks are used in each High Voltage Converter Modulator (HVCM) system at the Spallation Neutron Source (SNS) to generate drive currents to three boost transformer primaries switching between positive and negative bus voltages at 20 kHz. Every switch plate assembly is tested before installing it into an operational HVCM. A Single Phase Test Stand has been built for this purpose, and it is used for adjustment, measurement and testing of different configurations of switch plates. This paper will present a description of the Test Stand configuration and discuss the results of testing switch plates with twomore » different types of IGBT gate drivers currently in use on the HVCM systems. Comparison of timing characteristics of the original and new drivers and the resulting performance reinforces the necessity to replace the original H-bridge network drivers with the upgraded units.« less

  11. Digit ratio (2D:4D) and physical fitness (Eurofit test battery) in school children.

    PubMed

    Ranson, R; Stratton, G; Taylor, S R

    2015-05-01

    The relative lengths of the index finger to the ring finger (2D:4D) is sexually dimorphic and is thought to be a correlate of prenatal sex steroids (low 2D:4D=high prenatal testosterone and low prenatal oestrogen). In adults there have been reports that low 2D:4D is consistently associated with high sports performance. To investigate correlations between 2D:4D and fitness levels in children. Right 2D:4D and body size were measured, in addition to flexibility, speed, endurance and strength (Eurofit tests). 922 boys and 835 girls (mean ages (years): 10.8 ± 1.01 and 10.07 ± 1.00 respectively). height, mass, BMI, triceps and subscapular skinfolds, 20 m shuttle run, sit and reach, standing broad jump, hand grip strength, 10 × 5m sprint, and the sit and reach test. Boys significantly outperformed the girls in the 10 × 5m sprints, the 20 m shuttle run, standing broad jump, and hand grip strength. In boys but not girls, 2D:4D was significantly negatively correlated with scores in all these tests except the standing broad jump. In girls but not boys, 2D:4D was significantly positively correlated to stature, mass, BMI and waist circumference. It is suggested that high prenatal testosterone and low prenatal oestrogen (low 2D:4D) is implicated in high sprinting speed, endurance and hand grip strength in boys. In girls low prenatal testosterone and high prenatal oestrogen is associated with large body size. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  12. Experience with the selection method in pine stands in the southern United States, with implications for future application

    Treesearch

    James M. Guldin

    2011-01-01

    The selection method applied in shade-intolerant pine stands in the southern United States has been shown to be an effective method of uneven-aged silviculture, but it is becoming less frequently practiced for a variety of reasons. Economically, the high value of standing timber puts fully stocked uneven-aged pine stands at risk of liquidation if the timberland is sold...

  13. Community Structure and Standing Stock of Epibenthic Zooplankton at Five Sites in Grays Harbor, Washington

    DTIC Science & Technology

    1981-09-01

    4 GRAYS HARBOR AND CHEHALIS RIVER IMPROVEMENTS TO NAVIGATION ENVIRONMENTAL STUDIES COMMUNITY STRUCTURE AND STANDING © STOCK OF EPIBENTHIC... FISHERIES RESEARCH INSTITUTE %r UNIVERSITY OF WASHINGTON B of Engineers SEPTEMBER 1981 Seattle District(DISTRIBUTION STATEM EN T. -A-8-1 2 7 Approved...PERIOD COVERED Community Structure and Standing Stock of Final May 7. 1981 Epibenthic Zooplankton at Five Sites in 6. PERFORMING ORG. REPORT NUMBER

  14. Walking speed is associated with self-perceived hearing handicap in high-functioning older adults: The Fujiwara-kyo study.

    PubMed

    Tomioka, Kimiko; Harano, Akihiro; Hazaki, Kan; Morikawa, Masayuki; Iwamoto, Junko; Saeki, Keigo; Okamoto, Nozomi; Kurumatani, Norio

    2015-06-01

    The present study investigated whether physical performance and musculoskeletal pain (MSP) are associated with self-perceived hearing handicap (HH) among high-functioning older adults. We analyzed a total of 3982 community-dwelling high-functioning older adults (age 65 years and older). HH was assessed using the Hearing Handicap Inventory for Elderly-Screening. Self-reported hearing impairment (HI) was evaluated using a single question. We measured handgrip strength, walking speed (WS) and standing balance for assessments of physical performance. The severity of MSP assessed by interviews took into account its duration, limitation of daily activity and frequency. The prevalence of HH and HI in our sample was 22.2% and 28.1%, respectively. After adjusting for other two physical performance measures, MSP, sex, age, education, marital status, risk factors for hearing loss, instrumental activity of daily living, depression, cognitive function and self-reported HI, the odds ratios for HH in the second fastest, the second slowest, and the slowest WS quartile were 1.14 (95% CI = 0.81-1.58), 1.29 (95% CI = 0.92-1.79), and 1.58 (95% CI = 1.11-2.23), respectively, compared with the fastest WS quartile. A significant dose-response relationship was found between slower WS and HH (P for trend = 0.01). No significant association with HH was found in handgrip strength, standing balance and MSP. WS is associated with self-perceived HH in high-functioning older adults. The present study suggests that exercise programs to improve walking ability might be effective in preventing HH of self-sustainable older adults. © 2014 Japan Geriatrics Society.

  15. 2014 Behavioral Health and Performance Standing Review Panel

    NASA Technical Reports Server (NTRS)

    Steinberg, Susan; Leon, Gloria; Dimsdale, Joel; Balkin, Thomas; Bono, Joyce; Caldwell, John; Joiner, Thomas; Paulus, Martin; Zaccaro, Stephen

    2015-01-01

    The 2014 Behavioral Health and Performance (BHP) Standing Review Panel (from here on referred to as the SRP) met for a site visit in Houston, TX on December 17 - 18, 2014. The SRP reviewed the updated research plan for the Risk of Performance Errors Due to Fatigue Resulting from Sleep Loss, Circadian Desynchronization, Extended Wakefulness, and Work Overload (Sleep Risk) and also received a status update on the Risk of Adverse Behavioral Conditions and Psychiatric Disorders (BMed Risk) and the Risk of Performance Decrements Due to Inadequate Cooperation, Coordination, Communication, and Psychosocial Adaptation within a Team (Team Risk).

  16. Effect of yoga training on one leg standing and functional reach tests in obese individuals with poor postural control

    PubMed Central

    Jorrakate, Chaiyong; Kongsuk, Jutaluk; Pongduang, Chiraprapa; Sadsee, Boontiwa; Chanthorn, Phatchari

    2015-01-01

    [Purpose] The aim of the present study was to investigate the effect of yoga training on static and dynamic standing balance in obese individuals with poor standing balance. [Subjects and Methods] Sixteen obese volunteers were randomly assigned into yoga and control groups. The yoga training program was performed for 45 minutes per day, 3 times per week, for 4 weeks. Static and dynamic balance were assessed in volunteers with one leg standing and functional reach tests. Outcome measures were tested before training and after a single week of training. Two-way repeated measure analysis of variance with Tukey’s honestly significant difference post hoc statistics was used to analyze the data. [Results] Obese individuals showed significantly increased static standing balance in the yoga training group, but there was no significant improvement of static or dynamic standing balance in the control group after 4 weeks. In the yoga group, significant increases in static standing balance was found after the 2nd, 3rd, and 4th weeks. Compared with the control group, static standing balance in the yoga group was significantly different after the 2nd week, and dynamic standing balance was significantly different after the 4th week. [Conclusion] Yoga training would be beneficial for improving standing balance in obese individuals with poor standing balance. PMID:25642038

  17. Design of coated standing nanowire array solar cell performing beyond the planar efficiency limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeng, Yang; Ye, Qinghao; Shen, Wenzhong, E-mail: wzshen@sjtu.edu.cn

    2016-05-28

    The single standing nanowire (SNW) solar cells have been proven to perform beyond the planar efficiency limits in both open-circuit voltage and internal quantum efficiency due to the built-in concentration and the shifting of the absorption front. However, the expandability of these nano-scale units to a macro-scale photovoltaic device remains unsolved. The main difficulty lies in the simultaneous preservation of an effective built-in concentration in each unit cell and a broadband high absorption capability of their array. Here, we have provided a detailed theoretical guideline for realizing a macro-scale solar cell that performs furthest beyond the planar limits. The keymore » lies in a complementary design between the light-trapping of the single SNWs and that of the photonic crystal slab formed by the array. By tuning the hybrid HE modes of the SNWs through the thickness of a coaxial dielectric coating, the optimized coated SNW array can sustain an absorption rate over 97.5% for a period as large as 425 nm, which, together with the inherited carrier extraction advantage, leads to a cell efficiency increment of 30% over the planar limit. This work has demonstrated the viability of a large-size solar cell that performs beyond the planar limits.« less

  18. Acoustic radiation force on a rigid elliptical cylinder in plane (quasi)standing waves

    NASA Astrophysics Data System (ADS)

    Mitri, F. G.

    2015-12-01

    The acoustic radiation force on a 2D elliptical (non-circular) cylinder centered on the axis of wave propagation of plane quasi-standing and standing waves is derived, based on the partial-wave series expansion (PWSE) method in cylindrical coordinates. A non-dimensional acoustic radiation force function, which is the radiation force per unit length, per characteristic energy density and per unit cross-sectional surface of the ellipse, is defined in terms of the scattering coefficients that are determined by applying the Neumann boundary condition for an immovable surface. A system of linear equations involving a single numerical integration procedure is solved by matrix inversion. Numerical simulations showing the transition from the quasi-standing to the (equi-amplitude) standing wave behaviour are performed with particular emphasis on the aspect ratio a/b, where a and b are the ellipse semi-axes, as well as the dimensionless size parameter kb (where k is the wavenumber), without the restriction to a particular range of frequencies. It is found that at high kb values > 1, the radiation force per length with broadside incidence is larger, whereas the opposite situation occurs in the long-wavelength limit (i.e., kb < 1). The results are particularly relevant in acoustic levitation of elliptical cylinders, the acoustic stabilization of liquid columns in a host medium, acousto-fluidics devices, and other particle dynamics applications to name a few. Moreover, the formalism presented here may be effectively applied to compute the acoustic radiation force on other 2D surfaces of arbitrary shape such as super-ellipses, Chebyshev cylindrical particles, or other non-circular geometries.

  19. Differences in Fine-Root Biomass of Trees and Understory Vegetation among Stand Types in Subtropical Forests

    PubMed Central

    Fu, Xiaoli; Wang, Jianlei; Di, Yuebao; Wang, Huimin

    2015-01-01

    Variation of total fine-root biomass among types of tree stands has previously been attributed to the characteristics of the stand layers. The effects of the understory vegetation on total fine-root biomass are less well studied. We examined the variation of total fine-root biomass in subtropical tree stands at two sites of Datian and Huitong in China. The two sites have similar humid monsoon climate but different soil organic carbon. One examination compared two categories of basal areas (high vs. low basal area) in stands of single species. A second examination compared single-species and mixed stands with comparable basal areas. Low basal area did not correlate with low total fine-root biomass in the single-species stands. The increase in seedling density but decrease in stem density for the low basal area stands at Datian and the quite similar stand structures for the basal-area contrast at Huitong helped in the lack of association between basal area and total fine-root biomass at the two sites, respectively. The mixed stands also did not yield higher total fine-root biomasses. In addition to the lack of niche complementarity between tree species, the differences in stem and seedling densities and the belowground competition between the tree and non-tree species also contributed to the similarity of the total fine-root biomasses in the mixed and single-species stands. Across stand types, the more fertile site Datian yielded higher tree, non-tree and total fine-root biomasses than Huitong. However, the contribution of non-tree fine-root biomass to the total fine-root biomass was higher at Huitong (29.4%) than that at Datian (16.7%). This study suggests that the variation of total fine-root biomass across stand types not only was associated with the characteristics of trees, but also may be highly dependent on the understory layer. PMID:26047358

  20. Edaphic, salinity, and stand structural trends in chronosequences of native and non-native dominated riparian forests along the Colorado River, USA

    USGS Publications Warehouse

    Merritt, David M.; Shafroth, Patrick B.

    2012-01-01

    Tamarix spp. are introduced shrubs that have become among the most abundant woody plants growing along western North American rivers. We sought to empirically test the long-held belief that Tamarix actively displaces native species through elevating soil salinity via salt exudation. We measured chemical and physical attributes of soils (e.g., salinity, major cations and anions, texture), litter cover and depth, and stand structure along chronosequences dominated by Tamarix and those dominated by native riparian species (Populus or Salix) along the upper and lower Colorado River in Colorado and Arizona/California, USA. We tested four hypotheses: (1) the rate of salt accumulation in soils is faster in Tamarix-dominated stands than stands dominated by native species, (2) the concentration of salts in the soil is higher in mature stands dominated by Tamarix compared to native stands, (3) soil salinity is a function of Tamarix abundance, and (4) available nutrients are more concentrated in native-dominated stands compared to Tamarix-dominated stands. We found that salt concentration increases at a faster rate in Tamarix-dominated stands along the relatively free-flowing upper Colorado but not along the heavily-regulated lower Colorado. Concentrations of ions that are known to be preferentially exuded by Tamarix (e.g., B, Na, and Cl) were higher in Tamarix stands than in native stands. Soil salt concentrations in older Tamarix stands along the upper Colorado were sufficiently high to inhibit germination, establishment, or growth of some native species. On the lower Colorado, salinity was very high in all stands and is likely due to factors associated with floodplain development and the hydrologic effects of river regulation, such as reduced overbank flooding, evaporation of shallow ground water, higher salt concentrations in surface and ground water due to agricultural practices, and higher salt concentrations in fine-textured sediments derived from naturally saline parent material.

  1. Differences in Fine-Root Biomass of Trees and Understory Vegetation among Stand Types in Subtropical Forests.

    PubMed

    Fu, Xiaoli; Wang, Jianlei; Di, Yuebao; Wang, Huimin

    2015-01-01

    Variation of total fine-root biomass among types of tree stands has previously been attributed to the characteristics of the stand layers. The effects of the understory vegetation on total fine-root biomass are less well studied. We examined the variation of total fine-root biomass in subtropical tree stands at two sites of Datian and Huitong in China. The two sites have similar humid monsoon climate but different soil organic carbon. One examination compared two categories of basal areas (high vs. low basal area) in stands of single species. A second examination compared single-species and mixed stands with comparable basal areas. Low basal area did not correlate with low total fine-root biomass in the single-species stands. The increase in seedling density but decrease in stem density for the low basal area stands at Datian and the quite similar stand structures for the basal-area contrast at Huitong helped in the lack of association between basal area and total fine-root biomass at the two sites, respectively. The mixed stands also did not yield higher total fine-root biomasses. In addition to the lack of niche complementarity between tree species, the differences in stem and seedling densities and the belowground competition between the tree and non-tree species also contributed to the similarity of the total fine-root biomasses in the mixed and single-species stands. Across stand types, the more fertile site Datian yielded higher tree, non-tree and total fine-root biomasses than Huitong. However, the contribution of non-tree fine-root biomass to the total fine-root biomass was higher at Huitong (29.4%) than that at Datian (16.7%). This study suggests that the variation of total fine-root biomass across stand types not only was associated with the characteristics of trees, but also may be highly dependent on the understory layer.

  2. Increasing fire severity, alternate successional trajectories, and the carbon balance of Alaskan boreal forests

    NASA Astrophysics Data System (ADS)

    Mack, M. C.; Alexander, H. D.; Jean, M.; Melvin, A. M.; Johnstone, J. F.

    2016-12-01

    Climate-sensitive disturbances, such as wildfire, can feed back positively to climate warming via the carbon (C) cycle if C released by disturbance is not replaced over post-fire succession. In boreal forests, burning of carbon in deep organic soils is not only an important determinate of ecosystem element balance over the disturbance cycle, but also sets the conditions that control plant recruitment, species dominance and successional trajectory. Species dominance, in turn, has the potential to exert strong control over the plant-soil-microbial feedbacks that determine C and nutrient coupling, C storage, and ultimately, replacement of combusted C. We examined the consequences of increasing fire severity for C balance and C and nitrogen (N) coupling in Alaskan boreal forests. We estimated combustion losses in 90 black spruce (conifer) stands that burned in 2004. Over the next decade, we followed natural tree seedling establishment in these stands and used seedling species dominance identify conifer versus deciduous successional trajectories. We assembled data from 120 stands that varied in time after fire and successional trajectory, and estimated C and N dynamics across 150 years of post-fire succession for each trajectory. Conifer stands that burned with high severity transitioned to deciduous tree dominance after fire. These stands had smaller ecosystem pools of C and N before fire, lost a larger proportion of these pools during the fire, and began succession with smaller residual pools than stands that returned to conifer dominance after fire. Over secondary succession, deciduous stands accumulated about 10 times more carbon in aboveground biomass than conifer stands. Belowground biomass and soil carbon accumulation, by contrast, was about three times higher in the black spruce stands than in deciduous stands. As a result, net ecosystem C accumulation over the 100 year inter-fire interval was three times higher in deciduous stands than in coniferous stands. Nitrogen accumulation did not differ between the trajectories; high C:N ratio biomass accumulation in deciduous stands balanced low C:N ratio soil organic matter accumulation in conifer stands. The timing of N accumulation, however, differed substantially, supporting the idea that deciduous stands mine N from degrading permafrost after fire.

  3. High-Performance Flexible All-Solid-State Supercapacitor from Large Free-Standing Graphene-PEDOT/PSS Films.

    PubMed

    Liu, Yuqing; Weng, Bo; Razal, Joselito M; Xu, Qun; Zhao, Chen; Hou, Yuyang; Seyedin, Shayan; Jalili, Rouhollah; Wallace, Gordon G; Chen, Jun

    2015-11-20

    Although great attention has been paid to wearable electronic devices in recent years, flexible lightweight batteries or supercapacitors with high performance are still not readily available due to the limitations of the flexible electrode inventory. In this work, highly flexible, bendable and conductive rGO-PEDOT/PSS films were prepared using a simple bar-coating method. The assembled device using rGO-PEDOT/PSS electrode could be bent and rolled up without any decrease in electrochemical performance. A relatively high areal capacitance of 448 mF cm(-2) was achieved at a scan rate of 10 mV s(-1) using the composite electrode with a high mass loading (8.49 mg cm(-2)), indicating the potential to be used in practical applications. To demonstrate this applicability, a roll-up supercapacitor device was constructed, which illustrated the operation of a green LED light for 20 seconds when fully charged.

  4. High-Performance Flexible All-Solid-State Supercapacitor from Large Free-Standing Graphene-PEDOT/PSS Films

    NASA Astrophysics Data System (ADS)

    Liu, Yuqing; Weng, Bo; Razal, Joselito M.; Xu, Qun; Zhao, Chen; Hou, Yuyang; Seyedin, Shayan; Jalili, Rouhollah; Wallace, Gordon G.; Chen, Jun

    2015-11-01

    Although great attention has been paid to wearable electronic devices in recent years, flexible lightweight batteries or supercapacitors with high performance are still not readily available due to the limitations of the flexible electrode inventory. In this work, highly flexible, bendable and conductive rGO-PEDOT/PSS films were prepared using a simple bar-coating method. The assembled device using rGO-PEDOT/PSS electrode could be bent and rolled up without any decrease in electrochemical performance. A relatively high areal capacitance of 448 mF cm-2 was achieved at a scan rate of 10 mV s-1 using the composite electrode with a high mass loading (8.49 mg cm-2), indicating the potential to be used in practical applications. To demonstrate this applicability, a roll-up supercapacitor device was constructed, which illustrated the operation of a green LED light for 20 seconds when fully charged.

  5. Laser damage of free-standing nanometer membranes

    NASA Astrophysics Data System (ADS)

    Morimoto, Yuya; Roland, Iännis; Rennesson, Stéphanie; Semond, Fabrice; Boucaud, Philippe; Baum, Peter

    2017-12-01

    Many high-field/attosecond and ultrafast electron diffraction/microscopy experiments on condensed matter require samples in the form of free-standing membranes with nanometer thickness. Here, we report the measurement of the laser-induced damage threshold of 11 different free-standing nanometer-thin membranes of metallic, semiconducting, and insulating materials for 1-ps, 1030-nm laser pulses at 50 kHz repetition rate. We find a laser damage threshold that is very similar to each corresponding bulk material. The measurements also reveal a band gap dependence of the damage threshold as a consequence of different ionization rates. These results establish the suitability of free-standing nanometer membranes for high-field pump-probe experiments.

  6. Effects of disease severity and medication state on postural control asymmetry during challenging postural tasks in individuals with Parkinson's disease.

    PubMed

    Barbieri, Fabio A; Polastri, Paula F; Baptista, André M; Lirani-Silva, Ellen; Simieli, Lucas; Orcioli-Silva, Diego; Beretta, Victor S; Gobbi, Lilian T B

    2016-04-01

    The aim of this study was to investigate the effects of disease severity and medication state on postural control asymmetry during challenging tasks in individuals with Parkinson's disease (PD). Nineteen people with PD and 11 neurologically healthy individuals performed three standing task conditions: bipedal standing, tandem and unipedal adapted standing; the individuals with PD performed the tasks in ON and OFF medication state. The participants with PD were distributed into 2 groups according to disease severity: unilateral group (n=8) and bilateral group (n=11). The two PD groups performed the evaluations both under and without the medication. Two force plates were used to analyze the posture. The symmetric index was calculated for various of center of pressure. ANOVA one-way (groups) and two-way (PD groups×medication), with repeated measures for medication, were calculated. For main effects of group, the bilateral group was more asymmetric than CG. For main effects of medication, only unipedal adapted standing presented effects of PD medication. There was PD groups×medication interaction. Under the effects of medication, the unilateral group presented lower asymmetry of RMS in anterior-posterior direction and area than the bilateral group in unipedal adapted standing. In addition, the unilateral group presented lower asymmetry of mean velocity, RMS in anterior-posterior direction and area in unipedal standing and area in tandem adapted standing after a medication dose. Postural control asymmetry during challenging postural tasks was dependent on disease severity and medication state in people with PD. The bilateral group presented higher postural control asymmetry than the control and unilateral groups in challenging postural tasks. Finally, the medication dose was able to reduce postural control asymmetry in the unilateral group during challenging postural tasks. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. A SPATIAL ANALYSIS OF FINE-ROOT BIOMASS FROM STAND DATA IN OREGON AND WASHINGTON

    EPA Science Inventory

    Because of the high spatial variability of fine roots in natural forest stands, accurate estimates of stand-level fine root biomass are difficult and expensive to obtain by standard coring methods. This study compares two different approaches that employ aboveground tree metrics...

  8. Stand development and silviculture in bottomland hardwoods

    Treesearch

    J. Steven Meadows

    1993-01-01

    Silviculture for the production of high-quality timber in southern bottomland hardwood forests involves the application of environmentally sound practices in order to enhance the growth and quality of both individual trees and stands. To accomplish this purpose, silvicultural practices are typically used to regulate stand density, species composition, and stem quality...

  9. A SPATIAL ANALYSIS OF THE FINE ROOT BIOMASS FROM STAND DATA IN THE PACIFIC NORTHWEST

    EPA Science Inventory

    High spatial variability of fine roots in natural forest stands makes accurate estimates of stand-level fine root biomass difficult and expensive to obtain by standard coring methods. This study uses aboveground tree metrics and spatial relationships to improve core-based estima...

  10. Supercapacitor Operating At 200 Degrees Celsius

    PubMed Central

    Borges, Raquel S.; Reddy, Arava Leela Mohana; Rodrigues, Marco-Tulio F.; Gullapalli, Hemtej; Balakrishnan, Kaushik; Silva, Glaura G.; Ajayan, Pulickel M.

    2013-01-01

    The operating temperatures of current electrochemical energy storage devices are limited due to electrolyte degradation and separator instability at higher temperatures. Here we demonstrate that a tailored mixture of materials can facilitate operation of supercapacitors at record temperatures, as high as 200°C. Composite electrolyte/separator structures made from naturally occurring clay and room temperature ionic liquids, with graphitic carbon electrodes, show stable supercapacitor performance at 200°C with good cyclic stability. Free standing films of such high temperature composite electrolyte systems can become versatile functional membranes in several high temperature energy conversion and storage applications. PMID:23999206

  11. A straw chambers' tracker for the high rate experiment 835 at the Fermilab accumulator

    NASA Astrophysics Data System (ADS)

    Bagnasco, S.; Dughera, G.; Giraudo, G.; Govi, G.; Marchetto, F.; Menichetti, E.; Pastrone, N.; Rumerio, P.; Trapani, P. P.

    1998-02-01

    Two layers of proportional drift tubes (aluminum mylar straws) are staggered in two cylindrical light chambers to measure charged particles' azimuthal angle. To stand the high rates (˜10 kHz/ cm2) and minimize the pile-up of the high luminosity experiment 835 at FNAL, a fast ASIC Amplifier-Shaper-Discriminator (ASD-8B) was chosen. The front-end electronics, designed exclusively with SMD components, was mounted on the downstream end plug of each chamber to avoid oscillations and noise. Design, construction and operational performances of these detectors are presented.

  12. Metabolic syndrome in people with a long-standing spinal cord injury: associations with physical activity and capacity.

    PubMed

    de Groot, Sonja; Adriaansen, Jacinthe J; Tepper, Marga; Snoek, Govert J; van der Woude, Lucas H V; Post, Marcel W M

    2016-11-01

    This study investigated (i) the prevalence of the metabolic syndrome (MetS) in people with a long-standing spinal cord injury (SCI); (ii) whether personal or lesion characteristics are determinants of the MetS; and (iii) the association with physical activity or peak aerobic capacity on the MetS. In a cross-sectional study, persons with SCI (N = 223; time since injury of ≥10 years) were tested. The individual components of the MetS were assessed together with the physical activity measured by the Physical Activity Scale for Individuals with Physical Disabilities (PASIPD), while peak aerobic capacity was tested during a graded wheelchair exercise test on a treadmill. Thirty-nine percent of the participants had MetS. In a multivariate logistic regression analyses and after performing a backward regression analysis, only age and education were significant determinants of the MetS. A 10-year increase in age leads to a 1.5 times more chance to have the MetS. Furthermore, people with a low education will multiply the relative risk of MetS compared with people with high education by almost 2. With and without correcting for confounders, no significant relationship was found between PASIPD or peak aerobic capacity and the MetS. It can be concluded that the prevalence of the MetS is high (39%) in people with a long-standing SCI but is comparable to the general Dutch population. Older people and those with a lower education level are most at risk for the MetS. Physical activity and peak aerobic fitness were not related to the MetS in this group with a long-standing SCI.

  13. Higher climate warming sensitivity of Siberian larch in small than large forest islands in the fragmented Mongolian forest steppe.

    PubMed

    Khansaritoreh, Elmira; Dulamsuren, Choimaa; Klinge, Michael; Ariunbaatar, Tumurbaatar; Bat-Enerel, Banzragch; Batsaikhan, Ganbaatar; Ganbaatar, Kherlenchimeg; Saindovdon, Davaadorj; Yeruult, Yolk; Tsogtbaatar, Jamsran; Tuya, Daramragchaa; Leuschner, Christoph; Hauck, Markus

    2017-09-01

    Forest fragmentation has been found to affect biodiversity and ecosystem functioning in multiple ways. We asked whether forest size and isolation in fragmented woodlands influences the climate warming sensitivity of tree growth in the southern boreal forest of the Mongolian Larix sibirica forest steppe, a naturally fragmented woodland embedded in grassland, which is highly affected by warming, drought, and increasing anthropogenic forest destruction in recent time. We examined the influence of stand size and stand isolation on the growth performance of larch in forests of four different size classes located in a woodland-dominated forest-steppe area and small forest patches in a grassland-dominated area. We found increasing climate sensitivity and decreasing first-order autocorrelation of annual stemwood increment with decreasing stand size. Stemwood increment increased with previous year's June and August precipitation in the three smallest forest size classes, but not in the largest forests. In the grassland-dominated area, the tree growth dependence on summer rainfall was highest. Missing ring frequency has strongly increased since the 1970s in small, but not in large forests. In the grassland-dominated area, the increase was much greater than in the forest-dominated landscape. Forest regeneration decreased with decreasing stand size and was scarce or absent in the smallest forests. Our results suggest that the larch trees in small and isolated forest patches are far more susceptible to climate warming than in large continuous forests pointing to a grim future for the forests in this strongly warming region of the boreal forest that is also under high land use pressure. © 2017 John Wiley & Sons Ltd.

  14. One-dimensional acoustic standing waves in rectangular channels for flow cytometry.

    PubMed

    Austin Suthanthiraraj, Pearlson P; Piyasena, Menake E; Woods, Travis A; Naivar, Mark A; Lόpez, Gabriel P; Graves, Steven W

    2012-07-01

    Flow cytometry has become a powerful analytical tool for applications ranging from blood diagnostics to high throughput screening of molecular assemblies on microsphere arrays. However, instrument size, expense, throughput, and consumable use limit its use in resource poor areas of the world, as a component in environmental monitoring, and for detection of very rare cell populations. For these reasons, new technologies to improve the size and cost-to-performance ratio of flow cytometry are required. One such technology is the use of acoustic standing waves that efficiently concentrate cells and particles to the center of flow channels for analysis. The simplest form of this method uses one-dimensional acoustic standing waves to focus particles in rectangular channels. We have developed one-dimensional acoustic focusing flow channels that can be fabricated in simple capillary devices or easily microfabricated using photolithography and deep reactive ion etching. Image and video analysis demonstrates that these channels precisely focus single flowing streams of particles and cells for traditional flow cytometry analysis. Additionally, use of standing waves with increasing harmonics and in parallel microfabricated channels is shown to effectively create many parallel focused streams. Furthermore, we present the fabrication of an inexpensive optical platform for flow cytometry in rectangular channels and use of the system to provide precise analysis. The simplicity and low-cost of the acoustic focusing devices developed here promise to be effective for flow cytometers that have reduced size, cost, and consumable use. Finally, the straightforward path to parallel flow streams using one-dimensional multinode acoustic focusing, indicates that simple acoustic focusing in rectangular channels may also have a prominent role in high-throughput flow cytometry. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Forest fuel treatment detection using multi-temporal airborne lidar data and high-resolution aerial imagery: a case study in the Sierra Nevada Mountains, California

    Treesearch

    Yanjun Su; Qinghua Guo; Brandon M. Collins; Danny L. Fry; Tianyu Hu; Maggi Kelly

    2016-01-01

    Treatments to reduce forest fuels are often performed in forests to enhance forest health, regulate stand density, and reduce the risk of wildfires. Although commonly employed, there are concerns that these forest fuel treatments (FTs) may have negative impacts on certain wildlife species. Often FTs are planned across large landscapes, but the actual treatment extents...

  16. A rechargeable iodine-carbon battery that exploits ion intercalation and iodine redox chemistry.

    PubMed

    Lu, Ke; Hu, Ziyu; Ma, Jizhen; Ma, Houyi; Dai, Liming; Zhang, Jintao

    2017-09-13

    Graphitic carbons have been used as conductive supports for developing rechargeable batteries. However, the classic ion intercalation in graphitic carbon has yet to be coupled with extrinsic redox reactions to develop rechargeable batteries. Herein, we demonstrate the preparation of a free-standing, flexible nitrogen and phosphorus co-doped hierarchically porous graphitic carbon for iodine loading by pyrolysis of polyaniline coated cellulose wiper. We find that heteroatoms could provide additional defect sites for encapsulating iodine while the porous carbon skeleton facilitates redox reactions of iodine and ion intercalation. The combination of ion intercalation with redox reactions of iodine allows for developing rechargeable iodine-carbon batteries free from the unsafe lithium/sodium metals, and hence eliminates the long-standing safety issue. The unique architecture of the hierarchically porous graphitic carbon with heteroatom doping not only provides suitable spaces for both iodine encapsulation and cation intercalation but also generates efficient electronic and ionic transport pathways, thus leading to enhanced performance.Carbon-based electrodes able to intercalate Li + and Na + ions have been exploited for high performing energy storage devices. Here, the authors combine the ion intercalation properties of porous graphitic carbons with the redox chemistry of iodine to produce iodine-carbon batteries with high reversible capacities.

  17. Application of Atmospheric-Pressure Microwave Line Plasma for Low Temperature Process

    NASA Astrophysics Data System (ADS)

    Suzuki, Haruka; Nakano, Suguru; Itoh, Hitoshi; Sekine, Makoto; Hori, Masaru; Toyoda, Hirotaka

    2015-09-01

    Atmospheric pressure (AP) plasmas have been given much attention because of its high cost benefit and a variety of possibilities for industrial applications. In various kinds of plasma production technique, pulsed-microwave discharge plasma using slot antenna is attractive due to its ability of high-density and stable plasma production. In this plasma source, however, size of the plasma has been limited up to a few cm in length due to standing wave inside a waveguide. To solve this, we have proposed a newly-developed AP microwave plasma source that utilizes not standing wave but travelling wave. By using this plasma source, spatially-uniform AP line plasma with 40 cm in length was realized by pure helium discharge in 60 cm slot and with nitrogen gas additive of 1%. Furthermore, gas temperature as low as 400 K was realized in this device. In this study, as an example of low temperature processes, hydrophilic treatment of PET films was performed. Processing speed increased with pulse frequency and a water contact angle of ~20° was easily obtained within 5 s with no thermal damage to the substrate. To evaluate treatment-uniformity of long line length, PET films were treated by 90 cm slot-antenna plasma and uniform treatment performance was confirmed.

  18. Test Stand at the Rocket Engine Test Facility

    NASA Image and Video Library

    1973-02-21

    The thrust stand in the Rocket Engine Test Facility at the National Aeronautics and Space Administration (NASA) Lewis Research Center in Cleveland, Ohio. The Rocket Engine Test Facility was constructed in the mid-1950s to expand upon the smaller test cells built a decade before at the Rocket Laboratory. The $2.5-million Rocket Engine Test Facility could test larger hydrogen-fluorine and hydrogen-oxygen rocket thrust chambers with thrust levels up to 20,000 pounds. Test Stand A, seen in this photograph, was designed to fire vertically mounted rocket engines downward. The exhaust passed through an exhaust gas scrubber and muffler before being vented into the atmosphere. Lewis researchers in the early 1970s used the Rocket Engine Test Facility to perform basic research that could be utilized by designers of the Space Shuttle Main Engines. A new electronic ignition system and timer were installed at the facility for these tests. Lewis researchers demonstrated the benefits of ceramic thermal coatings for the engine’s thrust chamber and determined the optimal composite material for the coatings. They compared the thermal-coated thrust chamber to traditional unlined high-temperature thrust chambers. There were more than 17,000 different configurations tested on this stand between 1973 and 1976. The Rocket Engine Test Facility was later designated a National Historic Landmark for its role in the development of liquid hydrogen as a propellant.

  19. Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities.

    PubMed

    Villar, Rodrigo; Beltrame, Thomas; Hughson, Richard L

    2015-10-01

    We tested the validity of the Hexoskin wearable vest to monitor heart rate (HR), breathing rate (BR), tidal volume (VT), minute ventilation, and hip motion intensity (HMI) in comparison with laboratory standard devices during lying, sitting, standing, and walking. Twenty healthy young volunteers participated in this study. First, participants walked 6 min on a treadmill at speeds of 1, 3, and 4.5 km/h followed by increasing treadmill grades until 80% of their predicted maximal heart rate. Second, lying, sitting, and standing tasks were performed (5 min each) followed by 6 min of treadmill walking at 80% of their ventilatory threshold. Analysis of each individual's mean values under each resting or exercise condition by the 2 measurement systems revealed low coefficient of variation and high intraclass correlation values for HR, BR, and HMI. The Bland-Altman results from HR, BR, and HMI indicated no deviation of the mean value from zero and relatively small variability about the mean. VT and minute ventilation were provided in arbitrary units by the Hexoskin device; however, relative magnitude of change from Hexoskin closely tracked the laboratory standard method. Hexoskin presented low variability, good agreement, and consistency. The Hexoskin wearable vest was a valid and consistent tool to monitor activities typical of daily living such as different body positions (lying, sitting, and standing) and various walking speeds.

  20. Continuous and difficult discrete cognitive tasks promote improved stability in older adults.

    PubMed

    Lajoie, Yves; Jehu, Deborah A; Richer, Natalie; Chan, Alan

    2017-06-01

    Directing attention away from postural control and onto a cognitive task affords the emergence of automatic control processes. Perhaps the continuous withdrawal of attention from the postural task facilitates an automatization of posture as opposed to only intermittent withdrawal; however this is unknown in the aging population. Twenty older adults (69.9±3.5years) stood with feet together on a force platform for 60s while performing randomly assigned discrete and continuous cognitive tasks. Participants were instructed to stand comfortably with their arms by their sides while verbally responding to the auditory stimuli as fast as possible during the discrete tasks, or mentally performing the continuous cognitive tasks. Participants also performed single-task standing. Results demonstrate significant reductions in sway amplitude and sway variability for the difficult discrete task as well as the continuous tasks relative to single-task standing. The continuous cognitive tasks also prompted greater frequency of sway in the anterior-posterior direction compared to single-standing and discrete tasks, and greater velocity in both directions compared to single-task standing, which could suggest ankle stiffening. No differences in the simple discrete condition were shown compared to single-task standing, perhaps due to the simplicity of the task. Therefore, we propose that the level of difficulty of the task, the specific neuropsychological process engaged during the cognitive task, and the type of task (discrete vs. continuous) influence postural control in older adults. Dual-tasking is a common activity of daily living; this work provides insight into the age-related changes in postural stability and attention demand. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Performance of a Tracked Feller-Buncher with a Shear Head Operating in Small-Diameter Pine

    Treesearch

    J. Klepac

    2013-01-01

    A Tigercat 845D tracked feller-buncher equipped with a shear head was evaluated while performing a clearcut in a 15-year old Loblolly pine (Pinus taeda) plantation and a 18-year old natural stand. Mean density of the plantation was 573 TPA (Trees per Acre) while the natural stand averaged 328 TPA, with a slightly higher density of 390 TPA in the study area. Total cycle...

  2. A flexible mesoporous Li4Ti5O12-rGO nanocomposite film as free-standing anode for high rate lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Zhu, Kunxu; Gao, Hanyang; Hu, Guoxin

    2018-01-01

    Advanced flexible electrode is crucial in the development of flexible energy storage devices for emerging wearable and portable electronics. Herein, a free-standing flexible mesoporous Li4Ti5O12-rGO (LTO-rGO) nanocomposite film is rationally designed and fabricated for lithium ion batteries (LIBs). This efficient synthesis involves the growth of lithium titanate hydrate (LTH) precursors on the graphene oxide (GO) by a hydrothermal reaction, assembly into LTH-GO film by vacuum filtration with some extra GO added, and subsequent conversion into LTO-rGO nanocomposite film through calcination. When rGO content in the LTO-rGO film is set, the addition sequence of GO is found to affect its textural and mechanical properties. The resultant free-standing LTO-rGO electrode, taking advantages of high Li4Ti5O12 loading of 73.9%, mesoporous layer-stacked channels with good electron/ion conductivity, good mechanical strength, and enlarged electrode/electrolyte contact area, delivers excellent electrochemical performance (e.g., specific capacity of 135.4 mAh g-1 at 40 C) over the electrode of conventional configuration. Moreover, no organic but all inorganic reagents are used in the synthesis, offering an eco-friendly, cost-efficient, and easily scalable way to fabricate binder-free flexible electrode for LIBs.

  3. Process Hood Stand Support Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VAN KATWIJK, C.

    2000-04-03

    This package is written to comply with EN-6-035-00 for upgrade dedication of commercial grade items (CGI). The SNF-5953 CGI package provides the Technical evaluation to identify the critical characteristics and the acceptance criteria associated with the safety function of the Hood Stand Support Steel. Completion of the technical and quality requirements identified in the dedication package will provide enough data to be reasonably assured that CGI Hood Stand Support Steel will perform its SC function.

  4. Recommended Practices in Thrust Measurements

    DTIC Science & Technology

    2013-10-01

    Turin.5,38 This stand consists of two BeCu plates which hang from flexible BeCu mounts on a rigid block of Zerodur c, a material with a very low coe...2013 Figure 4. Example of a state-of-the-art hanging pendulum thrust stand. 38 Two spherical mirrors mounted on the plates form an optical cavity for...the Zerodur frame. Temperature control and careful choice of materials were used to minimize and correct for thermal drift. 2. Thrust Stand Performance

  5. Effect of alternating postures on cognitive performance for healthy people performing sedentary work.

    PubMed

    Schwartz, Bernhard; Kapellusch, Jay M; Schrempf, Andreas; Probst, Kathrin; Haller, Michael; Baca, Arnold

    2018-06-01

    Prolonged sitting is a risk factor for several diseases and the prevalence of worksite-based interventions such as sit-to-stand workstations is increasing. Although their impact on sedentary behaviour has been regularly investigated, the effect of working in alternating body postures on cognitive performance is unclear. To address this uncertainty, 45 students participated in a two-arm, randomised controlled cross-over trial under laboratory conditions. Subjects executed validated cognitive tests (working speed, reaction time, concentration performance) either in sitting or alternating working postures on two separate days (ClinicalTrials.gov Identifier: NCT02863731). MANOVA results showed no significant difference in cognitive performance between trials executed in alternating, standing or sitting postures. Perceived workload did not differ between sitting and alternating days. Repeated measures ANOVA revealed significant learning effects regarding concentration performance and working speed for both days. These results suggest that working posture did not affect cognitive performance in the short term. Practitioner Summary: Prior reports indicated health-related benefits based on alternated (sit/stand) body postures. Nevertheless, their effect on cognitive performance is unknown. This randomised controlled trial showed that working in alternating body postures did not influence reaction time, concentration performance, working speed or workload perception in the short term.

  6. A microNewton thrust stand for average thrust measurement of pulsed microthruster.

    PubMed

    Zhou, Wei-Jing; Hong, Yan-Ji; Chang, Hao

    2013-12-01

    A torsional thrust stand has been developed for the study of the average thrust for microNewton pulsed thrusters. The main body of the thrust stand mainly consists of a torsional balance, a pair of flexural pivots, a capacitive displacement sensor, a calibration assembly, and an eddy current damper. The behavior of the stand was thoroughly studied. The principle of thrust measurement was analyzed. The average thrust is determined as a function of the average equilibrium angle displacement of the balance and the spring stiffness. The thrust stand has a load capacity up to 10 kg, and it can theoretically measure the force up to 609.6 μN with a resolution of 24.4 nN. The static calibrations were performed based on the calibration assembly composed of the multiturn coil and the permanent magnet. The calibration results demonstrated good repeatability (less than 0.68% FSO) and good linearity (less than 0.88% FSO). The assembly of the multiturn coil and the permanent magnet was also used as an exciter to simulate the microthruster to further research the performance of the thrust stand. Three sets of force pulses at 17, 33.5, and 55 Hz with the same amplitude and pulse width were tested. The repeatability error at each frequency was 7.04%, 1.78%, and 5.08%, respectively.

  7. Densities of breeding birds and changes in vegetation in an alaskan boreal forest following a massive disturbance by spruce beetles

    USGS Publications Warehouse

    Matsuoka, S.M.; Handel, C.M.; Ruthrauff, D.R.

    2001-01-01

    We examined bird and plant communities among forest stands with different levels of spruce mortality following a large outbreak of spruce beetles (Dendroctonus rufipennis (Kirby)) in the Copper River Basin, Alaska. Spruce beetles avoided stands with black spruce (Picea mariana) and selectively killed larger diameter white spruce (Picea glauca), thereby altering forest structure and increasing the dominance of black spruce in the region. Alders (Alnus sp.) and crowberry (Empetrum nigrum) were more abundant in areas with heavy spruce mortality, possibly a response to the death of overstory spruce. Grasses and herbaceous plants did not proliferate as has been recorded following outbreaks in more coastal Alaskan forests. Two species closely tied to coniferous habitats, the tree-nesting Ruby-crowned Kinglet (Regulus calendula) and the red squirrel (Tamiasciurus hudsonicus), a major nest predator, were less abundant in forest stands with high spruce mortality than in low-mortality stands. Understory-nesting birds as a group were more abundant in forest stands with high levels of spruce mortality, although the response of individual bird species to tree mortality was variable. Birds breeding in stands with high spruce mortality likely benefited reproductively from lower squirrel densities and a greater abundance of shrubs to conceal nests from predators.

  8. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.; Sontag, Brendan D.

    2018-01-01

    A modal test of NASA's Space Launch System (SLS) Core Stage is scheduled to occur at the Stennis Space Center B2 test stand. A derrick crane with a 150-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview and application of the results.

  9. Performing a Large-Scale Modal Test on the B2 Stand Crane at NASA's Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Stasiunas, Eric C.; Parks, Russel A.

    2018-01-01

    A modal test of NASA’s Space Launch System (SLS) Core Stage is scheduled to occur prior to propulsion system verification testing at the Stennis Space Center B2 test stand. A derrick crane with a 180-ft long boom, located at the top of the stand, will be used to suspend the Core Stage in order to achieve defined boundary conditions. During this suspended modal test, it is expected that dynamic coupling will occur between the crane and the Core Stage. Therefore, a separate modal test was performed on the B2 crane itself, in order to evaluate the varying dynamic characteristics and correlate math models of the crane. Performing a modal test on such a massive structure was challenging and required creative test setup and procedures, including implementing both AC and DC accelerometers, and performing both classical hammer and operational modal analysis. This paper describes the logistics required to perform this large-scale test, as well as details of the test setup, the modal test methods used, and an overview of the results.

  10. Effects of Standing and Light-Intensity Walking and Cycling on 24-h Glucose.

    PubMed

    Crespo, Noe C; Mullane, Sarah L; Zeigler, Zachary S; Buman, Matthew P; Gaesser, Glenn A

    2016-12-01

    This study aimed to compare 24-h and postprandial glucose responses to incremental intervals of standing (STAND), walking (WALK), and cycling (CYCLE) to a sit-only (SIT) condition. Nine overweight/obese (body mass index = 29 ± 3 kg·m) adults (30 ± 15 yr) participated in this randomized crossover full-factorial study, with each condition performed 1 wk apart. STAND, CYCLE, and WALK intervals increased from 10 to 30 min·h (2.5 h total) during an 8-h workday. WALK (1.0 mph) and STAND were matched for upright time, and WALK and CYCLE were matched for energy expenditure (~2 METs). Continuous interstitial glucose monitoring was performed for 24 h to include the 8-h workday (LAB), after-work evening hours (EVE), and sleep (SLEEP). Three 2-h postprandial periods were also analyzed. Linear mixed models were used to test for condition differences. Compared with SIT (5.7 ± 1.0 mmol·L), mean 24-h glucose during STAND (5.4 ± 0.9 mmol·L) and WALK (5.3 ± 0.9 mmol·L) were lower, and CYCLE (5.1 ± 1.0 mmol·L) was lower than all other conditions (all P < 0.001). During LAB and EVE, mean glucose was lower for STAND, WALK, and CYCLE compared with SIT (P < 0.001). During SLEEP, the mean glucose for CYCLE was lower than all other conditions (P < 0.001). Compared with SIT, cumulative 6-h postprandial mean glucose was 5%-12% lower (P < 0.001) during STAND, WALK, and CYCLE, and 6-h postprandial glucose integrated area under the curve was 24% lower during WALK (P < 0.05) and 44% lower during CYCLE (P < 0.001). Replacing sitting with regular intervals of standing or light-intensity activity during an 8-h workday reduces 24-h and postprandial glucose. These effects persist during evening hours, with CYCLE having the largest and most sustained effect.

  11. Isopropyl alcohol tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  12. Water tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    A water tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen water, liquid oxygen (LOX) and isopropyl alcohol (IPA) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  13. Liquid oxygen tank installed at A-3 Test Stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    A liquid oxygen (LOX) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen LOX, isopropyl alcohol (IPA) and water tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  14. Water tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-08-13

    A water tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen water, liquid oxygen (LOX) and isopropyl alcohol (IPA) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  15. Liquid oxygen tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-09-18

    A liquid oxygen (LOX) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen LOX, isopropyl alcohol (IPA) and water tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  16. Isopropyl alcohol tank installed at A-3 Test Stand

    NASA Image and Video Library

    2009-09-18

    An isopropyl alcohol (IPA) tank is lifted into place at the A-3 Test Stand being built at NASA's John C. Stennis Space Center. Fourteen IPA, water and liquid oxygen (LOX) tanks are being installed to support the chemical steam generators to be used on the A-3 Test Stand. The IPA and LOX tanks will provide fuel for the generators. The water will allow the generators to produce steam that will be used to reduce pressure inside the stand's test cell diffuser, enabling operators to simulate altitudes up to 100,000 feet. In that way, operators can perform the tests needed on rocket engines being built to carry humans back to the moon and possibly beyond. The A-3 Test Stand is set for completion and activation in 2011.

  17. Standing wave design and experimental validation of a tandem simulated moving bed process for insulin purification.

    PubMed

    Xie, Yi; Mun, Sungyong; Kim, Jinhyun; Wang, Nien-Hwa Linda

    2002-01-01

    A tandem simulated moving bed (SMB) process for insulin purification has been proposed and validated experimentally. The mixture to be separated consists of insulin, high molecular weight proteins, and zinc chloride. A systematic approach based on the standing wave design, rate model simulations, and experiments was used to develop this multicomponent separation process. The standing wave design was applied to specify the SMB operating conditions of a lab-scale unit with 10 columns. The design was validated with rate model simulations prior to experiments. The experimental results show 99.9% purity and 99% yield, which closely agree with the model predictions and the standing wave design targets. The agreement proves that the standing wave design can ensure high purity and high yield for the tandem SMB process. Compared to a conventional batch SEC process, the tandem SMB has 10% higher yield, 400% higher throughput, and 72% lower eluant consumption. In contrast, a design that ignores the effects of mass transfer and nonideal flow cannot meet the purity requirement and gives less than 96% yield.

  18. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  19. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  20. Performance impact of novel polymeric dyes in photoresist applications

    NASA Astrophysics Data System (ADS)

    Lu, Ping-Hung; Mehtsun, Salem; Sagan, John P.; Shan, Jianhui; Gonzalez, Eleazar; Ding, Shuji; Khanna, Dinesh N.

    1999-06-01

    Dye compounds are commonly used in photoresists as a low cost and effective way to control swing and/or standing wave effect caused by thin film interference as well as reflective notching by reflective light from highly reflective substrate and topography. Convention dyes are typically a monomeric compound with high absorptivity at the wavelength of exposure light and compatible with the resist system selected. Because of the monomeric nature, conventional dyes are relatively low in molecular weight hence their thermal stability and sublimination propensity has always been an issue of concern. We recently synthesize several highly thermal stable diazotized polymeric dyes. Their thermal properties as well as compatibility with resist system were investigated. The impact of polymeric dyes on the resists lithographic performance, swing reduction and reflective notching control are discussed.

  1. Assembly of [Cu2(COO)4] and [M3(μ3-O)(COO)6] (M = Sc, Fe, Ga, and In) building blocks into porous frameworks towards ultra-high C2H2/CO2 and C2H2/CH4 separation performance.

    PubMed

    Zhang, Jian-Wei; Hu, Man-Cheng; Li, Shu-Ni; Jiang, Yu-Cheng; Qu, Peng; Zhai, Quan-Guo

    2018-02-20

    A porous MOF platform (SNNU-65s) formed by creatively combining paddle-wheel-like [Cu 2 (COO) 4 ] and trigonal prismatic [M 3 (μ 3 -O)(COO) 6 ] building blocks was designed herein. The mixed and high-density open metal sites and the OH-functionalized pore surface promote SNNU-65s to exhibit ultra-high C 2 H 2 uptake and separation performance. Impressively, SNNU-65-Cu-Ga stands out for the highest C 2 H 2 /CO 2 (18.7) and C 2 H 2 /CH 4 (120.6) selectivity among all the reported MOFs at room temperature.

  2. Yoga Poses Increase Subjective Energy and State Self-Esteem in Comparison to ‘Power Poses’

    PubMed Central

    Golec de Zavala, Agnieszka; Lantos, Dorottya; Bowden, Deborah

    2017-01-01

    Research on beneficial consequences of yoga focuses on the effects of yogic breathing and meditation. Less is known about the psychological effects of performing yoga postures. The present study investigated the effects of yoga poses on subjective sense of energy and self-esteem. The effects of yoga postures were compared to the effects of ‘power poses,’ which arguably increase the sense of power and self-confidence due to their association with interpersonal dominance (Carney et al., 2010). The study tested the novel prediction that yoga poses, which are not associated with interpersonal dominance but increase bodily energy, would increase the subjective feeling of energy and therefore increase self-esteem compared to ‘high power’ and ‘low power’ poses. A two factorial, between participants design was employed. Participants performed either two standing yoga poses with open front of the body (n = 19), two standing yoga poses with covered front of the body (n = 22), two expansive, high power poses (n = 21), or two constrictive, low power poses (n = 20) for 1-min each. The results showed that yoga poses in comparison to ‘power poses’ increased self-esteem. This effect was mediated by an increased subjective sense of energy and was observed when baseline trait self-esteem was controlled for. These results suggest that the effects of performing open, expansive body postures may be driven by processes other than the poses’ association with interpersonal power and dominance. This study demonstrates that positive effects of yoga practice can occur after performing yoga poses for only 2 min. PMID:28553249

  3. Numerical modeling of a 2K J-T heat exchanger used in Fermilab Vertical Test Stand VTS-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, Prabhat Kumar; Rabehl, Roger

    2014-07-01

    Fermilab Vertical Test Stand-1 (VTS-1) is in operation since 2007 for testing the superconducting RF cavities at 2 K. This test stand has single layer coiled finned tubes heat exchanger before J-T valve. A finite difference based thermal model has been developed in Engineering Equation Solver (EES) to study its thermal performance during filling and refilling to maintain the constant liquid level of test stand. The model is also useful to predict its performance under other various operating conditions and will be useful to design the similar kind of heat exchanger for future needs. Present paper discusses the different operationalmore » modes of this heat exchanger and its thermal characteristics under these operational modes. Results of this model have also been compared with the experimental data gathered from the VTS-1 heat exchanger and they are in good agreement with the present model.« less

  4. Cryogenic insulation development

    NASA Technical Reports Server (NTRS)

    Leonhard, K. E.

    1972-01-01

    Multilayer insulations for long term cryogenic storage are described. The development effort resulted in an insulation concept using lightweight radiation shields, separated by low conductive Dacron fiber tufts. The insulation is usually referred to as Superfloc. The fiber tufts are arranged in a triangular pattern and stand about .040 in. above the radiation shield base. Thermal and structural evaluation of Superfloc indicated that this material is a strong candidate for the development of high performance thermal protection systems because of its high strength, purge gas evacuation capability during boost, its density control and easy application to a tank.

  5. Minimum Performance on Clinical Tests of Physical Function to Predict Walking 6,000 Steps/Day in Knee Osteoarthritis: An Observational Study.

    PubMed

    Master, Hiral; Thoma, Louise M; Christiansen, Meredith B; Polakowski, Emily; Schmitt, Laura A; White, Daniel K

    2018-07-01

    Evidence of physical function difficulties, such as difficulty rising from a chair, may limit daily walking for people with knee osteoarthritis (OA). The purpose of this study was to identify minimum performance thresholds on clinical tests of physical function predictive to walking ≥6,000 steps/day. This benchmark is known to discriminate people with knee OA who develop functional limitation over time from those who do not. Using data from the Osteoarthritis Initiative, we quantified daily walking as average steps/day from an accelerometer (Actigraph GT1M) worn for ≥10 hours/day over 1 week. Physical function was quantified using 3 performance-based clinical tests: 5 times sit-to-stand test, walking speed (tested over 20 meters), and 400-meter walk test. To identify minimum performance thresholds for daily walking, we calculated physical function values corresponding to high specificity (80-95%) to predict walking ≥6,000 steps/day. Among 1,925 participants (mean ± SD age 65.1 ± 9.1 years, mean ± SD body mass index 28.4 ± 4.8 kg/m 2 , and 55% female) with valid accelerometer data, 54.9% walked ≥6,000 steps/day. High specificity thresholds of physical function for walking ≥6,000 steps/day ranged 11.4-14.0 seconds on the 5 times sit-to-stand test, 1.13-1.26 meters/second for walking speed, or 315-349 seconds on the 400-meter walk test. Not meeting these minimum performance thresholds on clinical tests of physical function may indicate inadequate physical ability to walk ≥6,000 steps/day for people with knee OA. Rehabilitation may be indicated to address underlying impairments limiting physical function. © 2017, American College of Rheumatology.

  6. Canopy transpiration of pure and mixed forest stands with variable abundance of European beech

    NASA Astrophysics Data System (ADS)

    Gebauer, Tobias; Horna, Viviana; Leuschner, Christoph

    2012-06-01

    SummaryThe importance of tree species identity and diversity for biogeochemical cycles in forests is not well understood. In the past, forestry has widely converted mixed forests to pure stands while contemporary forest policy often prefers mixed stands again. However, the hydrological consequences of these changes remain unclear. We tested the hypotheses (i) that significant differences in water use per ground area exist among the tree species of temperate mixed forests and that these differences are more relevant for the amount of stand-level canopy transpiration (Ec) than putative complementarity effects of tree water use, and (ii) that the seasonal patterns of Ec in mixed stands are significantly influenced by the identity of the present tree species. We measured xylem sap flux during 2005 (average precipitation) and 2006 (relatively dry) synchronously in three nearby old-growth forest stands on similar soil differing in the abundance of European beech (pure beech stand, 3-species stand with 70% beech, 5-species stand with <10% beech). In summer 2005 with average rainfall, Ec was 50% higher in the beech-poor 5-species stand than in the two stands with moderate to high beech presence (158 vs. 97 and 101 mm yr-1); in the dry summer 2006, all stands converged toward similar Ec totals (128-139 mm yr-1). Species differences in Ec were large on a sapwood area basis, reflecting a considerable variation in hydraulic architecture and leaf conductance regulation among the co-existing species. Moreover, transpiration per crown projection area (ECA) also differed up to 5-fold among the different species in the mixed stands, probably reflecting contrasting sapwood/crown area ratios. We conclude that Ec is not principally higher in mixed forests than in pure beech stands. However, tree species-specific traits have an important influence on the height of Ec and affect its seasonal variation. Species with a relatively high ECA (notably Tilia) may exhaust soil water reserves early in summer, thereby increasing drought stress in dry years and possibly reducing ecosystem stability in mixed forests.

  7. A 3D heterogeneous FeTiO3/TiO2@C fiber membrane as a self-standing anode for power Li-ion battery

    NASA Astrophysics Data System (ADS)

    Li, Jing-quan; Jing, Mao-xiang; Han, Chong; Yao, Shan-shan; Zhai, Hong-ai; Chen, Li-li; Shen, Xiang-qian; Xiao, Ke-song

    2018-04-01

    A three-dimensional (3D) networking FeTiO3/TiO2@C flexible fiber membrane was successfully fabricated by an electrospinning process and a controlled hot-press sintering method. This FeTiO3/TiO2@C fiber membrane displays a long-range continuous conductive networks, which can be directly used as self-standing anodes. The electrode sintered at 750 °C for 3 h possesses a reversible capacity of 205.4 mAh/g after 100 cycles at a current density of 300 mA/g. The superior cycle and rate performance can be attributed to the synergistic effect of little volume variation of TiO2 matrix, high capacity of FeTiO3 and good electrical conductivity of 3D networking.

  8. Process-Hardened, Multi-Analyte Sensor for Characterizing Rocket Plume Constituents

    NASA Technical Reports Server (NTRS)

    Goswami, Kisholoy

    2011-01-01

    A multi-analyte sensor was developed that enables simultaneous detection of rocket engine combustion-product molecules in a launch-vehicle ground test stand. The sensor was developed using a pin-printing method by incorporating multiple sensor elements on a single chip. It demonstrated accurate and sensitive detection of analytes such as carbon dioxide, carbon monoxide, kerosene, isopropanol, and ethylene from a single measurement. The use of pin-printing technology enables high-volume fabrication of the sensor chip, which will ultimately eliminate the need for individual sensor calibration since many identical sensors are made in one batch. Tests were performed using a single-sensor chip attached to a fiber-optic bundle. The use of a fiber bundle allows placement of the opto-electronic readout device at a place remote from the test stand. The sensors are rugged for operation in harsh environments.

  9. Performance and applications of a hypertemporal hyperspectral Fourier-transform infrared spectroradiometer

    NASA Astrophysics Data System (ADS)

    King, Bruce H.; Ellis, Thomas; Old, Tom E.

    2009-05-01

    A fast-scanning, high-resolution FTIR spectroradiometer has been designed and built for use in remote sensing, stand-off detection, and spectral-temporal characterization of fast, energetic infrared events. The instrument design uses a Michelson-type interferometer with a rotary modulator which is capable of continuous measurement of infrared spectra at a rate of 1000 scans per second with 4 cm-1 resolution in the 2 - 25 micron spectral range. Sensitivity, spectral accuracy, and radiometric precision are discussed along with specific design parameters. This instrument can be used for passive sensing as a stand-alone sensor, or for active sensing as a receiver when used in conjunction with a highenergy excitation source such as a laser. Applications include muzzle flash signature measurement, ordnance detonation characterization, missile plume identification, and rocket motor combustion diagnostics.

  10. Design Difficulties in Stand Density Studies

    Treesearch

    Frank A. Bennett

    1969-01-01

    Designing unbiased stand density studies is difficult. An acceptable sample requires stratification of the plots of age, site, and density. When basal area, percent stocking, or Reineke's stand density index is used as the density measure, this stratification forces a high negative correlation between site and number of trees per acre. Mortality in trees per acre...

  11. Effect of revised high-heeled shoes on foot pressure and static balance during standing.

    PubMed

    Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min

    2015-04-01

    [Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance.

  12. Effect of revised high-heeled shoes on foot pressure and static balance during standing

    PubMed Central

    Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min

    2015-01-01

    [Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance. PMID:25995572

  13. The effect of standing desks on manual control in children and young adults.

    PubMed

    Britten, L; Shire, K; Coats, R O; Astill, S L

    2016-07-01

    The aim of the present study was to establish if and how the additional postural constraint of standing affects accuracy and precision of goal directed naturalistic actions. Forty participants, comprising 20 young adults aged 20-23 years and 20 children aged 9-10 years completed 3 manual dexterity tasks on a tablet laptop with a handheld stylus during two separate conditions (1) while standing and (2) while seated. The order of conditions was counterbalanced across both groups of participants. The tasks were (1) a tracking task, where the stylus tracked a dot in a figure of 8 at 3 speeds, (2) an aiming task where the stylus moved from dot to dot with individual movements creating the outline of a pentagram and (3) a tracing task, where participants had to move the stylus along a static pathway or maze. Root mean squared error (RMSE), movement time and path accuracy, respectively, were used to quantify the effect that postural condition had on manual control. Overall adults were quicker and more accurate than children when performing all 3 tasks, and where the task speed was manipulated accuracy was better at slower speeds for all participants. Surprisingly, children performed these tasks more quickly and more accurately when standing compared to when sitting. In conclusion, standing at a desk while performing goal directed tasks did not detrimentally affect children's manual control, and moreover offered a benefit. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Effect of different types of exercise on postural balance in elderly women: a randomized controlled trial.

    PubMed

    de Oliveira, Marcio R; da Silva, Rubens A; Dascal, Juliana B; Teixeira, Denilson C

    2014-01-01

    Different types of exercise are indicated for the elderly to prevent functional capacity limitations due to aging and reduce the risk of falls. This study aimed to evaluate the effect of three different exercises (mini-trampoline, MT; aquatic gymnastics, AG and general floor gymnastics, GG) on postural balance in elderly women. Seventy-four physically independent elderly women, mean age 69±4 years, were randomly assigned to three intervention groups: (1) MT (n=23), (2) AG (n=28), and (3) GG (n=23). Each group performed physical training, including cardiorespiratory, muscular strength and endurance, flexibility and sensory-motor exercises for 12 weeks. To determine the effects on each intervention group, five postural balance tasks were performed on a force platform (BIOMEC 400): the two-legged stand with eyes open (TLEO) and two-legged stand with eyes closed (TLEC); the semi-tandem stand with eyes open (STEO) and semi-tandem stand with eyes closed (STEC) and the one-legged stand. Three trials were performed for each task (with 30s of rest between them) and the mean was used to compute balance parameters such as center of pressure (COP) sway movements. All modalities investigated such as the MT, AG and GG were significantly (P<0.05) efficient in improving the postural balance of elderly women after 12 weeks of training. These results provide further evidence concerning exercise and balance for promoting health in elderly women. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  15. Locomotor sensory organization test: a novel paradigm for the assessment of sensory contributions in gait.

    PubMed

    Chien, Jung Hung; Eikema, Diderik-Jan Anthony; Mukherjee, Mukul; Stergiou, Nicholas

    2014-12-01

    Feedback based balance control requires the integration of visual, proprioceptive and vestibular input to detect the body's movement within the environment. When the accuracy of sensory signals is compromised, the system reorganizes the relative contributions through a process of sensory recalibration, for upright postural stability to be maintained. Whereas this process has been studied extensively in standing using the Sensory Organization Test (SOT), less is known about these processes in more dynamic tasks such as locomotion. In the present study, ten healthy young adults performed the six conditions of the traditional SOT to quantify standing postural control when exposed to sensory conflict. The same subjects performed these six conditions using a novel experimental paradigm, the Locomotor SOT (LSOT), to study dynamic postural control during walking under similar types of sensory conflict. To quantify postural control during walking, the net Center of Pressure sway variability was used. This corresponds to the Performance Index of the center of pressure trajectory, which is used to quantify postural control during standing. Our results indicate that dynamic balance control during locomotion in healthy individuals is affected by the systematic manipulation of multisensory inputs. The sway variability patterns observed during locomotion reflect similar balance performance with standing posture, indicating that similar feedback processes may be involved. However, the contribution of visual input is significantly increased during locomotion, compared to standing in similar sensory conflict conditions. The increased visual gain in the LSOT conditions reflects the importance of visual input for the control of locomotion. Since balance perturbations tend to occur in dynamic tasks and in response to environmental constraints not present during the SOT, the LSOT may provide additional information for clinical evaluation on healthy and deficient sensory processing.

  16. Effect of a novel two-desk sit-to-stand workplace (ACTIVE OFFICE) on sitting time, performance and physiological parameters: protocol for a randomized control trial.

    PubMed

    Schwartz, Bernhard; Kapellusch, Jay M; Schrempf, Andreas; Probst, Kathrin; Haller, Michael; Baca, Arnold

    2016-07-15

    Prolonged sitting is ubiquitous in modern society and linked to several diseases. Height-adjustable desks are being used to decrease worksite based sitting time (ST). Single-desk sit-to-stand workplaces exhibit small ST reduction potential and short-term loss in performance. The aim of this paper is to report the study design and methodology of an ACTIVE OFFICE trial. The study was a 1-year three-arm, randomized controlled trial in 18 healthy Austrian office workers. Allocation was done via a regional health insurance, with data collection during Jan 2014 - March 2015. Participants were allocated to either an intervention or control group. Intervention group subjects were provided with traditional or two-desk sit-to-stand workstations in either the first or the second half of the study, while control subjects did not experience any changes during the whole study duration. Sitting time and physical activity (IPAQ-long), cognitive performance (text editing task, Stroop-test, d2R test of attention), workload perception (NASA-TLX) and physiological parameters (salivary cortisol, heartrate variability and body weight) were measured pre- and post-intervention (23 weeks after baseline) for intervention and control periods. Postural changes and sitting/standing time (software logger) were recorded at the workplace for the whole intervention period. This study evaluates the effects of a novel two-desk sit-to-stand workplace on sitting time, physical parameters and work performance of healthy office based workers. If the intervention proves effective, it has a great potential to be implemented in regular workplaces to reduce diseases related to prolonged sitting. ClinicalTrials.gov Identifier: NCT02825303 , July 2016 (retrospectively registered).

  17. Effects of disturbance and climate change on ecosystem performance in the Yukon River Basin boreal forest

    USGS Publications Warehouse

    Wylie, Bruce K.; Rigge, Matthew B.; Brisco, Brian; Mrnaghan, Kevin; Rover, Jennifer R.; Long, Jordan

    2014-01-01

    A warming climate influences boreal forest productivity, dynamics, and disturbance regimes. We used ecosystem models and 250 m satellite Normalized Difference Vegetation Index (NDVI) data averaged over the growing season (GSN) to model current, and estimate future, ecosystem performance. We modeled Expected Ecosystem Performance (EEP), or anticipated productivity, in undisturbed stands over the 2000–2008 period from a variety of abiotic data sources, using a rule-based piecewise regression tree. The EEP model was applied to a future climate ensemble A1B projection to quantify expected changes to mature boreal forest performance. Ecosystem Performance Anomalies (EPA), were identified as the residuals of the EEP and GSN relationship and represent performance departures from expected performance conditions. These performance data were used to monitor successional events following fire. Results suggested that maximum EPA occurs 30–40 years following fire, and deciduous stands generally have higher EPA than coniferous stands. Mean undisturbed EEP is projected to increase 5.6% by 2040 and 8.7% by 2070, suggesting an increased deciduous component in boreal forests. Our results contribute to the understanding of boreal forest successional dynamics and its response to climate change. This information enables informed decisions to prepare for, and adapt to, climate change in the Yukon River Basin forest.

  18. POLARIS: Agent-based modeling framework development and implementation for integrated travel demand and network and operations simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Auld, Joshua; Hope, Michael; Ley, Hubert

    This paper discusses the development of an agent-based modelling software development kit, and the implementation and validation of a model using it that integrates dynamic simulation of travel demand, network supply and network operations. A description is given of the core utilities in the kit: a parallel discrete event engine, interprocess exchange engine, and memory allocator, as well as a number of ancillary utilities: visualization library, database IO library, and scenario manager. The overall framework emphasizes the design goals of: generality, code agility, and high performance. This framework allows the modeling of several aspects of transportation system that are typicallymore » done with separate stand-alone software applications, in a high-performance and extensible manner. The issue of integrating such models as dynamic traffic assignment and disaggregate demand models has been a long standing issue for transportation modelers. The integrated approach shows a possible way to resolve this difficulty. The simulation model built from the POLARIS framework is a single, shared-memory process for handling all aspects of the integrated urban simulation. The resulting gains in computational efficiency and performance allow planning models to be extended to include previously separate aspects of the urban system, enhancing the utility of such models from the planning perspective. Initial tests with case studies involving traffic management center impacts on various network events such as accidents, congestion and weather events, show the potential of the system.« less

  19. CRionScan: A stand-alone real time controller designed to perform ion beam imaging, dose controlled irradiation and proton beam writing

    NASA Astrophysics Data System (ADS)

    Daudin, L.; Barberet, Ph.; Serani, L.; Moretto, Ph.

    2013-07-01

    High resolution ion microbeams, usually used to perform elemental mapping, low dose targeted irradiation or ion beam lithography needs a very flexible beam control system. For this purpose, we have developed a dedicated system (called “CRionScan”), on the AIFIRA facility (Applications Interdisciplinaires des Faisceaux d'Ions en Région Aquitaine). It consists of a stand-alone real-time scanning and imaging instrument based on a Compact Reconfigurable Input/Output (Compact RIO) device from National Instruments™. It is based on a real-time controller, a Field Programmable Gate Array (FPGA), input/output modules and Ethernet connectivity. We have implemented a fast and deterministic beam scanning system interfaced with our commercial data acquisition system without any hardware development. CRionScan is built under LabVIEW™ and has been used on AIFIRA's nanobeam line since 2009 (Barberet et al., 2009, 2011) [1,2]. A Graphical User Interface (GUI) embedded in the Compact RIO as a web page is used to control the scanning parameters. In addition, a fast electrostatic beam blanking trigger has been included in the FPGA and high speed counters (15 MHz) have been implemented to perform dose controlled irradiation and on-line images on the GUI. Analog to Digital converters are used for the beam current measurement and in the near future for secondary electrons imaging. Other functionalities have been integrated in this controller like LED lighting using Pulse Width Modulation and a “NIM Wilkinson ADC” data acquisition.

  20. Comparison of postural stability between injured and uninjured ballet dancers.

    PubMed

    Lin, Cheng-Feng; Lee, I-Jung; Liao, Jung-Hsien; Wu, Hong-Wen; Su, Fong-Chin

    2011-06-01

    Ballet movements require a limited base of support; thus, ballet dancers require a high level of postural control. However, postural stability in ballet dancers is still unclear and needs to be understood. To evaluate ballet dancers' postural stability in performing single-leg standing, the en pointe task, and the first and fifth positions and to determine differences in task performance among healthy nondancers, healthy dancers, and dancers with ankle sprains. Controlled laboratory study. Injured dancers, uninjured dancers, and nondancers were recruited for this study (N = 33 age-matched participants; n= 11 per group). The tasks tested were single-leg standing with eyes open and closed, first position, fifth position, and en pointe. Center of pressure parameters were calculated from the ground-reaction force collected with 1 force plate. Analysis of variance was used to assess the differences of center of pressure parameters among 3 groups in single-leg standing; independent t test was used to examine the differences of center of pressure parameters between injured and uninjured dancers. During single-leg standing, injured dancers had significantly greater maximum displacement in the medial-lateral direction and total trajectory of center of pressure, compared with the uninjured dancers and nondancers. During the first and fifth positions, the injured dancers demonstrated significantly greater standard deviation of center of pressure position in the medial-lateral and anterior-posterior directions, compared with the uninjured dancers. During en pointe, the injured dancers had significantly greater maximum displacement in the medial-lateral direction and the anterior-posterior direction, compared with the uninjured dancers. The injured and uninjured dancers demonstrated differences in postural stability in the medial-lateral direction during single-leg standing and the ballet postures. Although the injured dancers received ballet training, their postural stability may still be inferior to that of the nondancers. This study is a first step in understanding that injured ballet dancers do not have the same postural stability as uninjured dancers and that it is even inferior to that of nondancers, which is important to understand for further study on rehabilitation. The future development of effective balance training programs for ballet dancers with ankle injuries should emphasize improvements in medial-lateral directional balance.

  1. Outdoor test stand performance of a convertible engine with variable inlet guide vanes for advanced rotorcraft propulsion

    NASA Technical Reports Server (NTRS)

    Mcardle, Jack G.

    1986-01-01

    A variable inlet guide van (VIGV) type convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip airflow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss than was originally estimated. The new calculations confirm that using convertible engines rather than separate lift and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.

  2. Poly(3,4-ethylene-dioxythiophene)-poly(styrenesulfonate) glued and graphene encapsulated sulfur-carbon film for high-performance free-standing lithium-sulfur batteries

    NASA Astrophysics Data System (ADS)

    Wang, Zhiyu; Cheng, Jianli; Ni, Wei; Gao, Lizhen; Yang, Dan; Razal, Joselito M.; Wang, Bin

    2017-02-01

    A novel free-standing composite film electrode for Li-S battery is investigated. This novel electrode consists of polyvinylpyrrolidone-coated hollow sulfur microspheres (PVPS) that are homogeneously confined within the conductive composite matrix of graphene and poly(3,4-ethylene-dioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS). The characteristic large surface area and wrinkled surface of graphene sheets allow the formation of a conductive layer on the surface of PVPS to suppress the polysulfide dissolution and accommodate the volumetric expansion of sulfur. The addition of PEDOT-PSS also enhances the adhesion between the PVPS and the graphene surface, the overall conductivity of the electrode, and the charge transportation during the charging and discharging processes. The best electrode performances are achieved for a composite film cathode with a sulfur content of about 63.9%, which delivers an initial specific capacity of around 1060 mAh g-1 at 0.1 C. This electrode also displays an excellent capacity retention of 75% after 500 cycles at 1C, corresponding to a capacity decay of only 0.05% per cycle.

  3. Heterogeneity in homogeneous nucleation from billion-atom molecular dynamics simulation of solidification of pure metal.

    PubMed

    Shibuta, Yasushi; Sakane, Shinji; Miyoshi, Eisuke; Okita, Shin; Takaki, Tomohiro; Ohno, Munekazu

    2017-04-05

    Can completely homogeneous nucleation occur? Large scale molecular dynamics simulations performed on a graphics-processing-unit rich supercomputer can shed light on this long-standing issue. Here, a billion-atom molecular dynamics simulation of homogeneous nucleation from an undercooled iron melt reveals that some satellite-like small grains surrounding previously formed large grains exist in the middle of the nucleation process, which are not distributed uniformly. At the same time, grains with a twin boundary are formed by heterogeneous nucleation from the surface of the previously formed grains. The local heterogeneity in the distribution of grains is caused by the local accumulation of the icosahedral structure in the undercooled melt near the previously formed grains. This insight is mainly attributable to the multi-graphics processing unit parallel computation combined with the rapid progress in high-performance computational environments.Nucleation is a fundamental physical process, however it is a long-standing issue whether completely homogeneous nucleation can occur. Here the authors reveal, via a billion-atom molecular dynamics simulation, that local heterogeneity exists during homogeneous nucleation in an undercooled iron melt.

  4. Physical Conditioning through Water Exercises.

    ERIC Educational Resources Information Center

    Conrad, C. Carson

    This document describes activities in an aquatic program designed for an individual in sound health. Instructions for performing each activity are given in step-by-step outline form. The activities are arranged under the following categories: standing water drills; pool-side standing drills; gutter holding drills; bobbing (various forms);…

  5. Integrated fast assembly of free-standing lithium titanate/carbon nanotube/cellulose nanofiber hybrid network film as flexible paper-electrode for lithium-ion batteries.

    PubMed

    Cao, Shaomei; Feng, Xin; Song, Yuanyuan; Xue, Xin; Liu, Hongjiang; Miao, Miao; Fang, Jianhui; Shi, Liyi

    2015-05-27

    A free-standing lithium titanate (Li4Ti5O12)/carbon nanotube/cellulose nanofiber hybrid network film is successfully assembled by using a pressure-controlled aqueous extrusion process, which is highly efficient and easily to scale up from the perspective of disposable and recyclable device production. This hybrid network film used as a lithium-ion battery (LIB) electrode has a dual-layer structure consisting of Li4Ti5O12/carbon nanotube/cellulose nanofiber composites (hereinafter referred to as LTO/CNT/CNF), and carbon nanotube/cellulose nanofiber composites (hereinafter referred to as CNT/CNF). In the heterogeneous fibrous network of the hybrid film, CNF serves simultaneously as building skeleton and a biosourced binder, which substitutes traditional toxic solvents and synthetic polymer binders. Of importance here is that the CNT/CNF layer is used as a lightweight current collector to replace traditional heavy metal foils, which therefore reduces the total mass of the electrode while keeping the same areal loading of active materials. The free-standing network film with high flexibility is easy to handle, and has extremely good conductivity, up to 15.0 S cm(-1). The flexible paper-electrode for LIBs shows very good high rate cycling performance, and the specific charge/discharge capacity values are up to 142 mAh g(-1) even at a current rate of 10 C. On the basis of the mild condition and fast assembly process, a CNF template fulfills multiple functions in the fabrication of paper-electrode for LIBs, which would offer an ever increasing potential for high energy density, low cost, and environmentally friendly flexible electronics.

  6. The influence of high-heeled shoes on strain and tension force of the anterior talofibular ligament and plantar fascia during balanced standing and walking.

    PubMed

    Yu, Jia; Wong, Duo Wai-Chi; Zhang, Hongtao; Luo, Zong-Ping; Zhang, Ming

    2016-10-01

    High-heeled shoes have the capability to alter the strain and tension of ligamentous structures between the foot and ankle, which may result in ankle instability. However, high-heeled shoes can also reduce the strain on plantar fascia, which may be beneficial for the treatment of plantar fasciitis. In this study, the influence of heel height on strain and tension force applied to the anterior talofibular ligament (ATL) and plantar fascia were investigated. A three-dimensional finite element model of coupled foot-ankle-shoe complex was constructed. Four heel heights were studied in balanced standing: 0 in. (0cm), 1 in. (2.54cm), 2 in. (5.08cm), and 3 in. (7.62cm). A walking analysis was performed using 2-in. (5.08cm) high-heeled shoes. During balanced standing, the tension force on the ATL increased from 14.8N to 97.0N, with a six-fold increase in strain from 0 in. to 3 in. (0-7.62cm). The tension force and the average strain on the plantar fascia decreased from 151.0N (strain: 0.74%) to 59.6N (strain: 0.28%) when the heel height increased from 0 in. to 2 in. (0-5.08cm). When heel height reached 3 in. (7.62cm), the force and average strain increased to 278.3N (strain: 1.33%). The walking simulation showed that the fascia stretched out while the ATL loading decreased during push off. The simulation outcome demonstrated the influence of heel height on ATL alteration and plantar fascia strain, which implies risks for ankle injury and suggests guidance for the treatment of plantar fasciitis. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Effect of surface stability on core muscle activity for dynamic resistance exercises.

    PubMed

    Willardson, Jeffrey M; Fontana, Fabio E; Bressel, Eadric

    2009-03-01

    To compare core muscle activity during resistance exercises performed on stable ground vs. the BOSU Balance Trainer. Twelve trained men performed the back squat, dead lift, overhead press, and curl lifts. The activity of the rectus abdominis, external oblique abdominis, transversus abdominis/internal oblique abdominis, and erector spinae muscles was assessed. Subjects performed each lift under three separate conditions including standing on stable ground with 50% of a 1-RM, standing on a BOSU Balance Trainer with 50% of a 1-RM, and standing on stable ground with 75% of a 1-RM. Significant differences were noted between the stable 75% of 1-RM and BOSU 50% of 1-RM conditions for the rectus abdominis during the overhead press and transversus abdominis/internal oblique abdominis during the overhead press and curl (P < .05). Conversely, there were no significant differences between the stable 75% of 1-RM and BOSU 50% of 1-RM conditions for the external obliques and erector spinae across all lifts examined. Furthermore, there were no significant differences between the BOSU 50% of 1-RM and stable 50% of 1-RM conditions across all muscles and lifts examined. The current study did not demonstrate any advantage in utilizing the BOSU Balance Trainer. Therefore, fitness trainers should be advised that each of the aforementioned lifts can be performed while standing on stable ground without losing the potential core muscle training benefits.

  8. Effect of Standing or Walking at a Workstation on Cognitive Function: A Randomized Counterbalanced Trial.

    PubMed

    Bantoft, Christina; Summers, Mathew J; Tranent, Peter J; Palmer, Matthew A; Cooley, P Dean; Pedersen, Scott J

    2016-02-01

    In the present study, we examined the effect of working while seated, while standing, or while walking on measures of short-term memory, working memory, selective and sustained attention, and information-processing speed. The advent of computer-based technology has revolutionized the adult workplace, such that average adult full-time employees spend the majority of their working day seated. Prolonged sitting is associated with increasing obesity and chronic health conditions in children and adults. One possible intervention to reduce the negative health impacts of the modern office environment involves modifying the workplace to increase incidental activity and exercise during the workday. Although modifications, such as sit-stand desks, have been shown to improve physiological function, there is mixed information regarding the impact of such office modification on individual cognitive performance and thereby the efficiency of the work environment. In a fully counterbalanced randomized control trial, we assessed the cognitive performance of 45 undergraduate students for up to a 1-hr period in each condition. The results indicate that there is no significant change in the measures used to assess cognitive performance associated with working while seated, while standing, or while walking at low intensity. These results indicate that cognitive performance is not degraded with short-term use of alternate workstations. © 2015, Human Factors and Ergonomics Society.

  9. Tree density and permafrost thaw depth influence water limitations on stomatal conductance in Siberian Arctic boreal forests

    NASA Astrophysics Data System (ADS)

    Kropp, H.; Loranty, M. M.; Natali, S.; Kholodov, A. L.; Alexander, H. D.; Zimov, N.

    2017-12-01

    Boreal forests may experience increased water stress under global climate change as rising air temperatures increase evaporative demand and decrease soil moisture. Increases in plant water stress can decrease stomatal conductance, and ultimately, decrease primary productivity. A large portion of boreal forests are located in Siberia, and are dominated by deciduous needleleaf trees, Larix spp. We investigated the variability and drivers of canopy stomatal conductance in upland Larix stands with different stand density that arose from differing fire severity. Our measurements focus on an open canopy stand with low tree density and deep permafrost thaw depth, and a closed canopy stand with high tree density and shallow permafrost thaw depth. We measured canopy stomatal conductance, soil moisture, and micrometeorological variables. Our results demonstrate that canopy stomatal conductance was significantly lower in the closed canopy stand with a significantly higher sensitivity to increases in atmospheric evaporative demand. Canopy stomatal conductance in both stands was tightly coupled to precipitation that occurred over the previous week; however, the closed canopy stand showed a significantly greater sensitivity to increases in precipitation compared to the open canopy stand. Differences in access to deep versus shallow soil moisture and the physical characteristics of the soil profile likely contribute to differences in sensitivity to precipitation between the two stands. Our results indicate that Larix primary productivity may be highly sensitive to changes in evaporative demand and soil moisture that can result of global climate change. However, the effect of increasing air temperatures and changes in precipitation will differ significantly depending on stand density, thaw depth, and the hydraulic characteristics of the soil profile.

  10. The Nursing Home Physical Performance Test: A Secondary Data Analysis of Women in Long-Term Care Using Item Response Theory.

    PubMed

    Perera, Subashan; Nace, David A; Resnick, Neil M; Greenspan, Susan L

    2017-04-11

    The Nursing Home Physical Performance Test (NHPPT) was developed to measure function among nursing home residents using sit-to-stand, scooping applesauce, face washing, dialing phone, putting on sweater, and ambulating tasks. Using item response theory, we explore its measurement characteristics at item level and opportunities for improvements. We used data from long-term care women. We fitted a graded response model, estimated parameters, and constructed probability and information curves. We identified items to be targeted toward lower and higher functioning persons to increase the range of abilities to which the instrument is applicable. We revised the scoring by making sit-to-stand and sweater items harder and dialing phone easier. We examined changes to concurrent validity with activities of daily living (ADL), frailty, and cognitive function. Participants were 86 years old, had more than three comorbidities, and a NHPPT of 19.4. All items had high discrimination and were targeted toward the lower middle range of performance continuum. After revision, sit-to-stand and sweater items demonstrated greater discrimination among the higher functioning and/or greater spread of thresholds for response categories. The overall test showed discrimination over a wider range of individuals. Concurrent validity correlation improved from 0.60 to 0.68 for instrumental ADL and explained variability (R2) from 22% to 36% for frailty. NHPPT has good measurement characteristics at the item level. NHPPT can be improved, implemented in computerized adaptive testing, and combined with self-report for greater utility, but a definitive study is needed. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  11. Heading assessment by “tunnel vision” patients and control subjects standing or walking in a virtual reality environment

    PubMed Central

    APFELBAUM, HENRY; PELAH, ADAR; PELI, ELI

    2007-01-01

    Virtual reality locomotion simulators are a promising tool for evaluating the effectiveness of vision aids to mobility for people with low vision. This study examined two factors to gain insight into the verisimilitude requirements of the test environment: the effects of treadmill walking and the suitability of using controls as surrogate patients. Ten “tunnel vision” patients with retinitis pigmentosa (RP) were tasked with identifying which side of a clearly visible obstacle their heading through the virtual environment would lead them, and were scored both on accuracy and on their distance from the obstacle when they responded. They were tested both while walking on a treadmill and while standing, as they viewed a scene representing progress through a shopping mall. Control subjects, each wearing a head-mounted field restriction to simulate the vision of a paired patient, were also tested. At wide angles of approach, controls and patients performed with a comparably high degree of accuracy, and made their choices at comparable distances from the obstacle. At narrow angles of approach, patients’ accuracy increased when walking, while controls’ accuracy decreased. When walking, both patients and controls delayed their decisions until closer to the obstacle. We conclude that a head-mounted field restriction is not sufficient for simulating tunnel vision, but that the improved performance observed for walking compared to standing suggests that a walking interface (such as a treadmill) may be essential for eliciting natural perceptually-guided behavior in virtual reality locomotion simulators. PMID:18167511

  12. Heading assessment by "tunnel vision" patients and control subjects standing or walking in a virtual reality environment.

    PubMed

    Apfelbaum, Henry; Pelah, Adar; Peli, Eli

    2007-01-01

    Virtual reality locomotion simulators are a promising tool for evaluating the effectiveness of vision aids to mobility for people with low vision. This study examined two factors to gain insight into the verisimilitude requirements of the test environment: the effects of treadmill walking and the suitability of using controls as surrogate patients. Ten "tunnel vision" patients with retinitis pigmentosa (RP) were tasked with identifying which side of a clearly visible obstacle their heading through the virtual environment would lead them, and were scored both on accuracy and on their distance from the obstacle when they responded. They were tested both while walking on a treadmill and while standing, as they viewed a scene representing progress through a shopping mall. Control subjects, each wearing a head-mounted field restriction to simulate the vision of a paired patient, were also tested. At wide angles of approach, controls and patients performed with a comparably high degree of accuracy, and made their choices at comparable distances from the obstacle. At narrow angles of approach, patients' accuracy increased when walking, while controls' accuracy decreased. When walking, both patients and controls delayed their decisions until closer to the obstacle. We conclude that a head-mounted field restriction is not sufficient for simulating tunnel vision, but that the improved performance observed for walking compared to standing suggests that a walking interface (such as a treadmill) may be essential for eliciting natural perceptually-guided behavior in virtual reality locomotion simulators.

  13. Advanced Graphene-Based Binder-Free Electrodes for High-Performance Energy Storage.

    PubMed

    Ji, Junyi; Li, Yang; Peng, Wenchao; Zhang, Guoliang; Zhang, Fengbao; Fan, Xiaobin

    2015-09-23

    The increasing demand for energy has triggered tremendous research effort for the development of high-performance and durable energy-storage devices. Advanced graphene-based electrodes with high electrical conductivity and ion accessibility can exhibit superior electrochemical performance in energy-storage devices. Among them, binder-free configurations can enhance the electron conductivity of the electrode, which leads to a higher capacity by avoiding the addition of non-conductive and inactive binders. Graphene, a 2D material, can be fabricated into a porous and flexible structure with an interconnected conductive network. Such a conductive structure is favorable for both electron and ion transport to the entire electrode surface. In this review, the main processes used to prepare binder-free graphene-based hybrids with high porosity and well-designed electron conductive networks are summarized. Then, the applications of free-standing binder-free graphene-based electrodes in energy-storage devices are discussed. Future research aspects with regard to overcoming the technological bottlenecks are also proposed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Density, ages, and growth rates in old-growth and young-growth forests in coastal Oregon

    USGS Publications Warehouse

    Tappeiner, J. C.; Huffman, D.; Spies, T.; Bailey, John D.

    1997-01-01

    We studied the ages and diameter growth rates of trees in former Douglas-fir (Pseudotsuga menziesii (Mirb.)Franco) old-growth stands on 10 sites and compared them with young-growth stands (50-70 years old, regenerated after timber harvest) in the Coast Range of western Oregon. The diameters and diameter growth rates for the first 100 years of trees in the old-growth stands were significantly greater than those in the young-growth stands. Growth rates in the old stands were comparable with those from long-term studies of young stands in which density is about 100-120 trees/ha; often young-growth stand density is well over 500 trees/ha. Ages of large trees in the old stands ranged from 100 to 420 years; ages in young stands varied by only about 5 to 10 years. Apparently, regeneration of old-growth stands on these sites occurred over a prolonged period, and trees grew at low density with little self-thinning; in contrast, after timber harvest, young stands may develop with high density of trees with similar ages and considerable self-thinning. The results suggest that thinning may be needed in dense young stands where the management objective is to speed development of old-growth characteristics.

  15. Conjunction of standing wave and resonance in asymmetric nanowires: a mechanism for thermal rectification and remote energy accumulation.

    PubMed

    Liu, Yue-Yang; Zhou, Wu-Xing; Chen, Ke-Qiu

    2015-12-02

    As an important way to control and manage heat transport, thermal rectification has become an elementary issue in the field of phononics and plays a key role in the designing of thermal devices. Here we investigate systematically the standing wave and the accompanying resonance process in asymmetric nanowires to understand the standing wave itself and its great effect on thermal rectification. Results show that the standing wave is sensitive to both the structural and thermal properties of the material, and its great effect on enhancing the thermal rectification is realized not only by the energy-localization nature of the standing wave, but also by the resonance-caused large amplitude and high energy of the standing wave.

  16. Atmospheric CO2 mole fraction affects stand-scale carbon use efficiency of sunflower by stimulating respiration in light.

    PubMed

    Gong, Xiao Ying; Schäufele, Rudi; Lehmeier, Christoph Andreas; Tcherkez, Guillaume; Schnyder, Hans

    2017-03-01

    Plant carbon-use-efficiency (CUE), a key parameter in carbon cycle and plant growth models, quantifies the fraction of fixed carbon that is converted into net primary production rather than respired. CUE has not been directly measured, partly because of the difficulty of measuring respiration in light. Here, we explore if CUE is affected by atmospheric CO 2 . Sunflower stands were grown at low (200 μmol mol -1 ) or high CO 2 (1000 μmol mol -1 ) in controlled environment mesocosms. CUE of stands was measured by dynamic stand-scale 13 C labelling and partitioning of photosynthesis and respiration. At the same plant age, growth at high CO 2 (compared with low CO 2 ) led to 91% higher rates of apparent photosynthesis, 97% higher respiration in the dark, yet 143% higher respiration in light. Thus, CUE was significantly lower at high (0.65) than at low CO 2 (0.71). Compartmental analysis of isotopic tracer kinetics demonstrated a greater commitment of carbon reserves in stand-scale respiratory metabolism at high CO 2 . Two main processes contributed to the reduction of CUE at high CO 2 : a reduced inhibition of leaf respiration by light and a diminished leaf mass ratio. This work highlights the relevance of measuring respiration in light and assessment of the CUE response to environment conditions. © 2016 John Wiley & Sons Ltd.

  17. Influence of hamstring muscles extensibility on spinal curvatures and pelvic tilt in highly trained cyclists.

    PubMed

    Muyor, José M; Alacid, Fernando; López-Miñarro, Pedro A

    2011-09-01

    The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º - 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles.

  18. Influence of Hamstring Muscles Extensibility on Spinal Curvatures and Pelvic Tilt in Highly Trained Cyclists

    PubMed Central

    Muyor, José M.; Alacid, Fernando; López-Miñarro, Pedro A.

    2011-01-01

    The purpose of this study was to determine the influence of hamstring muscles extensibility in standing, maximal trunk flexion with knees extended and on the bicycle in lower handlebar-hands position of highly trained cyclists. Ninety-six cyclists were recruited for the study (mean ± SD, age: 30.36 ± 5.98 years). Sagittal spinal curvatures and pelvic tilt were measured in the standing position, maximal trunk flexion with knees extended (sit-and-reach test) and while sitting on a bicycle in lower handlebar-hand position using a Spinal Mouse system. Hamstring muscles extensibility was determined in both legs by passive straight leg raise test (PSLR). The sample was divided into three groups according to PSLR angle: (1) reduced extensibility (PSLR < 80º; n = 30), (2) moderate hamstring extensibility group (PSLR = 80º – 90º; n = 35), and (3) high hamstring extensibility (PSLR = > 90º; n = 31). ANOVA analysis showed significant differences among groups for thoracic (p < 0.001) and pelvic tilt (p < 0.001) angles in the sit-and-reach test. No differences were found between groups for standing and on the bicycle position. Post hoc analysis showed significant differences in all pairwise comparisons for thoracic angle (p < 0.01) and pelvic angle (p < 0.001) in the sit-and-reach test. No differences were found in lumbar angle in any posture. In conclusion, the hamstring muscles extensibility influence the thoracic and pelvic postures when maximal trunk flexion with knees extended is performed, but not when cyclists are seated on their bicycles PMID:23486997

  19. Engineers conduct key water test for A-3 stand

    NASA Technical Reports Server (NTRS)

    2009-01-01

    Water cascades from the A-2 Test Stand at Stennis Space Center as engineers challenge the limits of the high-pressure water system as part of the preparation process for the A-3 Test Stand under construction. Jeff Henderson, test director for Stennis' A Complex, led a series of tests Nov. 16-20, flowing water simultaneously on the A-1 and A-2 stands, followed by the A-1 and B-1 stands, to determine if the high-pressure industrial water facility pumps and the existing pipe system can support the needs of the A-3 stand. The stand is being built to test rocket engines that will carry astronauts beyond low-Earth orbit and will need about 300,000 gallons of water per minute when operating, but the Stennis system never had been tested to that level. The recent tests were successful in showing the water facility pumps can operate at that capacity - reaching 318,000 gallons per minute in one instance. However, officials continue to analyze data to determine if the system can provide the necessary pressure at that capacity and if the delivery system piping is adequate. 'We just think if there's a problem, it's better to identify and address it now rather than when A-3 is finished and it has to be dealt with,' Henderson said.

  20. Twenty-four years after theYellowstone Fires: Are postfire lodgepole pine stands converging in structure and function?

    PubMed

    Turner, Monica G; Whitby, Timothy G; Tinker, Daniel B; Romme, William H

    2016-05-01

    Disturbance and succession have long been of interest in ecology, but how landscape patterns of ecosystem structure and function evolve following large disturbances is poorly understood. After nearly 25 years, lodgepole pine (Pinus contorta var. latifolia) forests that regenerated after the 1988 Yellowstone Fires (Wyoming, USA) offer a prime opportunity to track the fate of disturbance-created heterogeneity in stand structure and function in a wilderness setting. In 2012, we resampled 72 permanent plots to ask (1) How have postfire stand structure and function changed between 11 and 24 yr postfire, and what variables explain these patterns and changes? (2) How has landscape-level (among-stand) variability in postfire stand structure and function changed between 11 and 24 yr postfire? We expected to see evidence of convergence beginning to emerge, but also that initial postfire stem density would still determine trajectories of biomass accumulation. After 24 yr, postfire lodgepole pine density remained very high (mean = 21,738 stems/ha, range = 0-344,067 stems/ha). Stem density increased in most plots between 11 and 24 yr postfire, but declined sharply where 11-yr-postfire stem density was > 72,000 stems/ha. Stems were small in high-density stands, but stand-level lodgepole pine leaf area, foliage biomass, and live aboveground biomass increased over time and with increasing stem density. After 24 yr, mean annual lodgepole pine aboveground net primary production (ANPP) was high (mean = 5 Mg · ha⁻¹ · yr⁻¹, range = 0-16.5 Mg · ha⁻¹ · yr⁻¹). Among stands, lodgepole pine ANPP increased with stem density, which explained 69% of the variation; another 8% of the variation was explained by environmental covariates. Early patterns of postfire lodgepole pine regeneration, which were contingent on prefire serotiny and fire severity, remained the dominant driver of stand structure and function. We observed mechanisms that would lead to convergence in stem density (structure) over time, but it was landscape variation in functional variables that declined substantially. Stand structure and function have not converged across the burned landscape, but our evidence suggests function will converge sooner than structure.

  1. Active Nodal Task Seeking for High-Performance, Ultra-Dependable Computing

    DTIC Science & Technology

    1994-07-01

    implementation. Figure 1 shows a hardware organization of ANTS: stand-alone computing nodes inter - connected by buses. 2.1 Run Time Partitioning The...nodes in 14 respond to changing loads [27] or system reconfiguration [26]. Existing techniques are all source-initiated or server-initiated [27]. 5.1...short-running task segments. The task segments must be short-running in order that processors will become avalable often enough to satisfy changing

  2. Analysis of colliding vehicle interactions for the passenger rail train-to-train impact test

    DOT National Transportation Integrated Search

    2004-04-06

    A full-scale train-to-train impact test was performed in : which a cab car-led passenger train traveling at 30 mph collided : with a standing locomotive-led train. During the test, the lead : cab car overrode the cab of the standing locomotive, susta...

  3. From defective hardwood stand to multiple use opportunity

    Treesearch

    Charles E. McGee

    1972-01-01

    A 40-year old clearcutting, originally made as an example of destructive logging, now supports one of the best mixed hardwood stands on the Bent Creek Experimental Forest. Such desirable intolerants as yellow-poplar provide potential for timber; some high- and low-quality oaks provide timber and wildlife values; and the entire young stand has a pleasing appearance....

  4. Effects of deer exclosures on oak regeneration in closed-canopy stands

    Treesearch

    Angela M. Yuska; Kim C. Steiner; James C. Finley

    2008-01-01

    Studies of the effects of high deer densities on forest regeneration have shown altered species composition and reduced diversity in stands regenerating after harvest. The effects of browsing in fully stocked, undisturbed stands are less well known but important, as establishment of seedlings of oaks and other species prior to disturbance is very important for self-...

  5. SSC Test Operations Contract Overview

    NASA Technical Reports Server (NTRS)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  6. Converting Virginia pine stump diameters to diameters breast high

    Treesearch

    Thomas W., Jr. Church

    1953-01-01

    Up until the last decade, practically no forest-management work had been done in stands of Virginia pine (Pinus virginiana Miller). It is still common practice to clear-cut the stand - with no consideration for a future crop. In some places this has resulted in satisfactory establishment of another pine stand. But usually hardwoods take over the site...

  7. Haemophilia & Exercise Project (HEP): subjective and objective physical performance in adult haemophilia patients--results of a cross-sectional study.

    PubMed

    Czepa, D; Von Mackensen, S; Hilberg, T

    2012-01-01

    Recurrent musculoskeletal haemorrhages in people with haemophilia (PWH) lead to restrictions in the locomotor system and consequently in physical performance. Patients' perceptions of their health status have gained an important role in the last few years. The assessment of subjective physical performance in PWH is a new approach. This study aimed to compare the subjective physical performance of PWH with healthy controls and to correlate the results with objective data. Subjective physical performance was assessed via the new questionnaire HEP-Test-Q, which consists of 25 items pertaining to four subscales 'mobility', 'strength & coordination', 'endurance' and 'body perception'. HEP-Test-Q subscales were compared with objective data in terms of range of motion, one-leg-stand and 12-minute walk test. Forty-eight patients (44 ± 11 years) with haemophilia A (43 severe, three moderate) or B (two severe) and 43 controls without haemophilia (42 ± 11 years) were enrolled. PWH showed an impaired subjective physical performance in all HEP-Test-Q subscales and in the total score (52 ± 20) compared with controls (77 ± 10; P ≤ 0.001). Correlation analyses for the total score of the HEP-Test-Q and objective data revealed values ranging from r = 0.403 (one-leg-stand) to r = 0.757 (12-minute walk test) (P ≤ 0.001). PWH evaluated their physical performance poorer in comparison with healthy people. As self-assessment did not always correlate highly with objective data, objective examinations of physical performance in PWH should be complemented with subjective perceptions. © 2011 Blackwell Publishing Ltd.

  8. Core stability training: applications to sports conditioning programs.

    PubMed

    Willardson, Jeffrey M

    2007-08-01

    In recent years, fitness practitioners have increasingly recommended core stability exercises in sports conditioning programs. Greater core stability may benefit sports performance by providing a foundation for greater force production in the upper and lower extremities. Traditional resistance exercises have been modified to emphasize core stability. Such modifications have included performing exercises on unstable rather than stable surfaces, performing exercises while standing rather than seated, performing exercises with free weights rather than machines, and performing exercises unilaterally rather than bilaterally. Despite the popularity of core stability training, relatively little scientific research has been conducted to demonstrate the benefits for healthy athletes. Therefore, the purpose of this review was to critically examine core stability training and other issues related to this topic to determine useful applications for sports conditioning programs. Based on the current literature, prescription of core stability exercises should vary based on the phase of training and the health status of the athlete. During preseason and in-season mesocycles, free weight exercises performed while standing on a stable surface are recommended for increases in core strength and power. Free weight exercises performed in this manner are specific to the core stability requirements of sports-related skills due to moderate levels of instability and high levels of force production. Conversely, during postseason and off-season mesocycles, Swiss ball exercises involving isometric muscle actions, small loads, and long tension times are recommended for increases in core endurance. Furthermore, balance board and stability disc exercises, performed in conjunction with plyometric exercises, are recommended to improve proprioceptive and reactive capabilities, which may reduce the likelihood of lower extremity injuries.

  9. Performance of a 100 kW class applied field MPD thruster

    NASA Technical Reports Server (NTRS)

    Mantenieks, Maris A.; Sovey, James S.; Myers, Roger M.; Haag, Thomas W.; Raitano, Paul; Parkes, James E.

    1989-01-01

    Performance of a 100 kW, applied field magnetoplasmadynamic (MPD) thruster was evaluated and sensitivities of discharge characteristics to arc current, mass flow rate, and applied magnetic field were investigated. Thermal efficiencies as high as 60 percent, thrust efficiencies up to 21 percent, and specific impulses of up to 1150 s were attained with argon propellant. Thrust levels up to 2.5 N were directly measured with an inverted pendulum thrust stand at discharge input powers up to 57 kW. It was observed that thrust increased monotonically with the product of arc current and magnet current.

  10. Healthy Concessions: High School Students' Responses to Healthy Concession Stand Changes

    ERIC Educational Resources Information Center

    Laroche, Helena H.; Hradek, Christine; Hansen, Kate; Hanks, Andrew S.; Just, David R.; Wansink, Brian

    2017-01-01

    Background: A previous sales data analysis demonstrated success in selling healthier items at a concession stand. Questions remained regarding student satisfaction and whether the intervention reached non-health-conscious students. Methods: Cross-sectional anonymous samples of students at a large midwestern high school were surveyed before and…

  11. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    PubMed

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  12. Suitable reverberation times for halls for rock and pop music.

    PubMed

    Adelman-Larsen, Niels Werner; Thompson, Eric R; Gade, Anders C

    2010-01-01

    The existing body of literature regarding the acoustic design of concert halls has focused almost exclusively on classical music, although there are many more performances of popular music, including rock and pop. Objective measurements were made of the acoustics of 20 rock music venues in Denmark and a questionnaire was used in a subjective assessment of those venues with professional rock musicians and sound engineers as expert listeners. Correlations between the measurements show that clarity, including bass frequencies down to 63 Hz, is important for the general impression of the acoustics of the hall. The best-rated halls in the study have reverberation times that are approximately frequency independent from 0.6 to 1.2 s for hall volumes from 1000 to 6000 m(3). The worst rated halls in the study had significantly higher reverberation times in the 63 and 125 Hz bands. Since most audiences at rock concerts are standing, absorption coefficients were measured with a standing audience from 63 Hz to 4 kHz. These measurements showed that a standing audience absorbs about five times as much energy in mid-/high-frequency bands as in low-frequency bands.

  13. Incorporation of Mg in Free-Standing HVPE GaN Substrates

    NASA Astrophysics Data System (ADS)

    Zvanut, M. E.; Dashdorj, J.; Freitas, J. A.; Glaser, E. R.; Willoughby, W. R.; Leach, J. H.; Udwary, K.

    2016-06-01

    Mg, the only effective p-type dopant for nitrides, is well studied in thin films due to the important role of the impurity in light-emitting diodes and high-power electronics. However, there are few reports of Mg in thick free-standing GaN substrates. Here, we demonstrate successful incorporation of Mg into GaN grown by hydride vapor-phase epitaxy (HVPE) using metallic Mg as the doping source. The concentration of Mg obtained from four separate growth runs ranged between 1016 cm-3 and 1019 cm-3. Raman spectroscopy and x-ray diffraction revealed that Mg did not induce stress or perturb the crystalline quality of the HVPE GaN substrates. Photoluminescence (PL) and electron paramagnetic resonance (EPR) spectroscopies were performed to investigate the types of point defects in the crystals. The near-band-edge excitonic and shallow donor-shallow acceptor radiative recombination processes involving shallow Mg acceptors were prominent in the PL spectrum of a sample doped to 3 × 1018 cm-3, while the EPR signal was also thought to represent a shallow Mg acceptor. Detection of this signal reflects minimization of nonuniform strain obtained in the thick free-standing HVPE GaN compared with heteroepitaxial thin films.

  14. Two weeks of additional standing balance circuit classes during inpatient rehabilitation are cost saving and effective: an economic evaluation.

    PubMed

    Treacy, Daniel; Howard, Kirsten; Hayes, Alison; Hassett, Leanne; Schurr, Karl; Sherrington, Catherine

    2018-01-01

    Among people admitted for inpatient rehabilitation, is usual care plus standing balance circuit classes more cost-effective than usual care alone? Cost-effectiveness study embedded within a randomised controlled trial with concealed allocation, assessor blinding and intention-to-treat analysis. 162 rehabilitation inpatients from a metropolitan hospital in Sydney, Australia. The experimental group received a 1-hour standing balance circuit class, delivered three times a week for 2 weeks, in addition to usual therapy. The circuit classes were supervised by one physiotherapist and one physiotherapy assistant for up to eight patients. The control group received usual therapy alone. Costs were estimated from routinely collected hospital use data in the 3 months after randomisation. The functional outcome measure was mobility measured at 3 months using the Short Physical Performance Battery administered by a blinded assessor. An incremental analysis was conducted and the joint probability distribution of costs and outcomes was examined using bootstrapping. The median cost savings for the intervention group was AUD4,741 (95% CI 137 to 9,372) per participant; 94% of bootstraps showed that the intervention was both effective and cost saving. Two weeks of additional standing balance circuit classes delivered in addition to usual therapy resulted in decreased healthcare costs at 3 months in hospital inpatients admitted for rehabilitation. There is a high probability that this intervention is both cost saving and effective. ACTRN12611000412932. [Treacy D, Howard K, Hayes A, Hassett L, Schurr K, Sherrington C (2018) Two weeks of additional standing balance circuit classes during inpatient rehabilitation are cost saving and effective: an economic evaluation. Journal of Physiotherapy 64: 41-47]. Copyright © 2017 Australian Physiotherapy Association. Published by Elsevier B.V. All rights reserved.

  15. Is psychological membership in the classroom a function of standing out while fitting in? Implications for achievement motivation and emotions.

    PubMed

    Gray, DeLeon L

    2017-04-01

    Education researchers have consistently linked students' perceptions of "fitting in" at school with patterns of motivation and positive emotions. This study proposes that "standing out" is also helpful for producing these outcomes, and that standing out works in concert with perceptions of fitting in. In a sample of 702 high school students nested within 33 classrooms, principal components analysis and confirmatory factor analysis were each conducted on half of the sample. Results support the proposed structure of measures of standing out and fitting in. Multilevel latent profile analysis was then used to classify students into four profiles of standing out while fitting in (SOFI): Unfulfilled, Somewhat Fulfilled, Nearly Fulfilled, and Fulfilled. A multinomial logistic regression revealed that students of color and those on who paid free/reduced prices lunch were overrepresented in the Unfulfilled and Somewhat Fulfilled profiles. A multilevel path analysis was then performed to assess the direct and indirect associations of profile membership with measures of task value and achievement emotions. Relative to the other profiles, students in the Fulfilled SOFI Profile express greater psychological membership in their classrooms and, in turn, express higher valuing of academic material (i.e., intrinsic value, utility value, and attainment value) and more positive achievement emotions (i.e., more enjoyment and pride; less boredom, hopelessness, and shame). This investigation provides critical insights on the potential benefits of structuring academic learning environments to foster feelings of distinctiveness among adolescents; and has implications for cultivating identities and achievement motivation in academic settings. Copyright © 2017 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  16. Acoustic radiation force on a rigid elliptical cylinder in plane (quasi)standing waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitri, F. G., E-mail: F.G.Mitri@ieee.org

    2015-12-07

    The acoustic radiation force on a 2D elliptical (non-circular) cylinder centered on the axis of wave propagation of plane quasi-standing and standing waves is derived, based on the partial-wave series expansion (PWSE) method in cylindrical coordinates. A non-dimensional acoustic radiation force function, which is the radiation force per unit length, per characteristic energy density and per unit cross-sectional surface of the ellipse, is defined in terms of the scattering coefficients that are determined by applying the Neumann boundary condition for an immovable surface. A system of linear equations involving a single numerical integration procedure is solved by matrix inversion. Numericalmore » simulations showing the transition from the quasi-standing to the (equi-amplitude) standing wave behaviour are performed with particular emphasis on the aspect ratio a/b, where a and b are the ellipse semi-axes, as well as the dimensionless size parameter kb (where k is the wavenumber), without the restriction to a particular range of frequencies. It is found that at high kb values > 1, the radiation force per length with broadside incidence is larger, whereas the opposite situation occurs in the long-wavelength limit (i.e., kb < 1). The results are particularly relevant in acoustic levitation of elliptical cylinders, the acoustic stabilization of liquid columns in a host medium, acousto-fluidics devices, and other particle dynamics applications to name a few. Moreover, the formalism presented here may be effectively applied to compute the acoustic radiation force on other 2D surfaces of arbitrary shape such as super-ellipses, Chebyshev cylindrical particles, or other non-circular geometries.« less

  17. Generation of uniform large-area very high frequency plasmas by launching two specific standing waves simultaneously

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Hsin-Liang, E-mail: hlchen@iner.gov.tw; Tu, Yen-Cheng; Hsieh, Cheng-Chang

    2014-09-14

    With the characteristics of higher electron density and lower ion bombardment energy, large-area VHF (very high frequency) plasma enhanced chemical vapor deposition has become an essential manufacturing equipment to improve the production throughput and efficiency of thin film silicon solar cell. However, the combination of high frequency and large electrodes leads to the so-called standing wave effect causing a serious problem for the deposition uniformity of silicon thin film. In order to address this issue, a technique based on the idea of simultaneously launching two standing waves that possess similar amplitudes and are out of phase by 90° in timemore » and space is proposed in this study. A linear plasma reactor with discharge length of 54 cm is tested with two different frequencies including 60 and 80 MHz. The experimental results show that the proposed technique could effectively improve the non-uniformity of VHF plasmas from >±60% when only one standing wave is applied to <±10% once two specific standing waves are launched at the same time. Moreover, in terms of the reactor configuration adopted in this study, in which the standing wave effect along the much shorter dimension can be ignored, the proposed technique is applicable to different frequencies without the need to alter the number and arrangement of power feeding points.« less

  18. Vertically cross-linked and porous CoNi2S4 nanosheets-decorated SiC nanowires with exceptional capacitive performance as a free-standing electrode for asymmetric supercapacitors

    NASA Astrophysics Data System (ADS)

    Zhao, Jian; Li, Zhenjiang; Zhang, Meng; Meng, Alan; Li, Qingdang

    2016-11-01

    In this paper, a simple, low-cost and mild hydrothermal technology of growing vertically cross-linked ternary nickel cobalt sulfides nanosheets (CoNi2S4 NSs) with porous characteristics on SiC nanowires (SiC NWs) supporters with outstanding resistances to oxidation and corrosion, good conductivity and large specific surface area deposited directly on carbon cloth (CC) is successfully developed, forming a new family of free-standing advanced hybrid electrode for asymmetric supercapacitors (ASCs). Such integrated electrode (SiC NWs@CoNi2S4 NSs) manifests intriguing electrochemical characteristics such as high specific capacity (231.1 mA h g-1 at 2 A g-1) and rate capability due to the synergistic effect of SiC NWs and CoNi2S4 NSs with unique morphology. Additionally, an asymmetric supercapacitor is also assembled via using this special hybrid architectures as positive electrode and activated carbon (AC) on Ni foam (NF) as negative electrode, and it can yield a high energy density of 57.8 W h kg-1 with a power density of 1.6 kW kg-1 and long cycling lifespan. This study constitutes an emerging attractive strategy to reasonably design and fabricate novel SiC NWs-based nanostructured electrodes with enhanced capacity, which holds great potential to be the candidate of electrode materials for environmentally benign as well as high-performance energy storage devices.

  19. 3D nitrogen-doped graphene foam with encapsulated germanium/nitrogen-doped graphene yolk-shell nanoarchitecture for high-performance flexible Li-ion battery

    PubMed Central

    Mo, Runwei; Rooney, David; Sun, Kening; Yang, Hui Ying

    2017-01-01

    Flexible electrochemical energy storage devices have attracted extensive attention as promising power sources for the ever-growing field of flexible and wearable electronic products. However, the rational design of a novel electrode structure with a good flexibility, high capacity, fast charge–discharge rate and long cycling lifetimes remains a long-standing challenge for developing next-generation flexible energy-storage materials. Herein, we develop a facile and general approach to three-dimensional (3D) interconnected porous nitrogen-doped graphene foam with encapsulated Ge quantum dot/nitrogen-doped graphene yolk-shell nano architecture for high specific reversible capacity (1,220 mAh g−1), long cycling capability (over 96% reversible capacity retention from the second to 1,000 cycles) and ultra-high rate performance (over 800 mAh g−1 at 40 C). This work paves a way to develop the 3D interconnected graphene-based high-capacity electrode material systems, particularly those that suffer from huge volume expansion, for the future development of high-performance flexible energy storage systems. PMID:28051065

  20. Space Shuttle Projects

    NASA Image and Video Library

    1978-09-01

    This photograph shows stacking of the left side of the solid rocket booster (SRB) segments in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). Staging shown here are the aft skirt, aft segment, and aft center segment. The SRB was attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT is to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB's to which the ET was attached.

  1. Space Shuttle Projects

    NASA Image and Video Library

    1978-09-01

    This photograph shows the left side of the solid rocket booster (SRB) segment as it awaits being mated to the nose cone and forward skirt in the Dynamic Test Stand at the east test area of the Marshall Space Flight Center (MSFC). The SRB would be attached to the external tank (ET) and then the orbiter later for the Mated Vertical Ground Vibration Test (MVGVT), that resumed in October 1978. The stacking of a complete Shuttle in the Dynamic Test Stand allowed test engineers to perform ground vibration testing on the Shuttle in its liftoff configuration. The purpose of the MVGVT was to verify that the Space Shuttle would perform as predicted during launch. The platforms inside the Dynamic Test Stand were modified to accommodate two SRB's to which the ET was attached.

  2. Effect of sitting pause times on postural stability after supine-to-standing transfer in dimly lit environments.

    PubMed

    Johnson, Eric G; Meltzer, Jonathan D

    2012-01-01

    Falls are common and often take place in the home. Risk of fall increases if the environment is dimly lit. Longer sitting pause times, before standing, might improve postural stability after standing from a supine position. The purpose of this investigation was to measure the effects of sitting pause times on postural sway velocity immediately following a supine-to-standing transfer in a dimly lit room in older and younger adult women. Five women aged 65 to 70 years and 5 aged 23 to 30 years participated in the study. On each of 2 consecutive days, study participants lay on a mat table with their eyes closed for 45 minutes before performing a supine-to-standing transfer in a dimly lit room. Sitting pause times of 2 seconds and 30 seconds preceded the transfers. Mean postural sway velocity for the whole sample and for younger and older groups was less after a 30-second pause time than that after a 2-second pause time (sample, P = .001; young, P = .019; old, P = .021). No significant difference in mean postural sway velocity was observed between the 2 groups (P > .05). Total mean postural sway velocity was less when study participants performed a sitting pause of 30 seconds before standing in a dimly lit room. These results suggest that longer sitting pause times may provide improved adaptability to dimly lit environments contributing to improved postural stability.

  3. Design and application of electromechanical actuators for deep space missions

    NASA Technical Reports Server (NTRS)

    Haskew, Tim A.; Wander, John

    1993-01-01

    During the period 8/16/92 through 2/15/93, work has been focused on three major topics: (1) screw modeling and testing; (2) motor selection; and (3) health monitoring and fault diagnosis. Detailed theoretical analysis has been performed to specify a full dynamic model for the roller screw. A test stand has been designed for model parameter estimation and screw testing. In addition, the test stand is expected to be used to perform a study on transverse screw loading.

  4. FTOOLS: A FITS Data Processing and Analysis Software Package

    NASA Astrophysics Data System (ADS)

    Blackburn, J. Kent; Greene, Emily A.; Pence, William

    1993-05-01

    FTOOLS, a highly modular collection of utilities for processing and analyzing data in the FITS (Flexible Image Transport System) format, has been developed in support of the HEASARC (High Energy Astrophysics Research Archive Center) at NASA's Goddard Space Flight Center. Each utility performs a single simple task such as presentation of file contents, extraction of specific rows or columns, appending or merging tables, binning values in a column or selecting subsets of rows based on a boolean expression. Individual utilities can easily be chained together in scripts to achieve more complex operations such as the generation and displaying of spectra or light curves. The collection of utilities provides both generic processing and analysis utilities and utilities common to high energy astrophysics data sets. The FTOOLS software package is designed to be both compatible with IRAF and completely stand alone in a UNIX or VMS environment. The user interface is controlled by standard IRAF parameter files. The package is self documenting through the IRAF help facility and a stand alone help task. Software is written in ANSI C and FORTRAN to provide portability across most computer systems. The data format dependencies between hardware platforms are isolated through the FITSIO library package.

  5. The effect of high tibial osteotomy on osteoarthritis of the knee : Clinical and histological observations.

    PubMed

    Koshino, T; Tsuchiya, K

    1979-03-01

    High tibial osteotomies were performed on 136 osteoarthritic knees for correction of varus deformity. Before osteotomy all patients experienced moderate or severe pain, and the knees showed lateral thrust on weight-bearing. The patients were followed up for one to five years. Marked relief of pain was obtained in 112 knees, and the patients were satisfied with the result of operation in 122. These painless knees showed no lateral thrust, and in the majority the deformity had been adequately corrected, with post-operative femoro-tibial angles (standing) ranging from 165° to 174°. Four of 28 knees with femoro-tibial angles of 175° to 179°, when measured one year after operation, showed recurrence of varus deformity three years after osteotomy. Preoperative ranges of knee motion were well maintained after osteotomy even when arthrotomy had also been undertaken. Intra-articular assessment in two patients, several years after operation, showed that the most degenerated portions of the articular surface were completely covered by a fibrocartilagenous layer, with no bare bone.High tibial osteotomy is most effective in osteoarthritic knees with varus deformity, when correction is made to a femoro-tibial angle (standing) of 170° (10° valgus).

  6. The effect of high tibial osteotomy on osteoarthritis of the knee. Clinical and histological observations.

    PubMed

    Koshino, T; Tsuchiya, K

    1979-01-01

    High tibial osteotomies were performed on 136 osteoarthritic knees for correction of varus deformity. Before osteotomy all patients experienced moderate or severe pain, and the knees showed lateral thrust on weight-bearing. The patients were followed up for one to five years. Marked relief of pain was obtained in 112 knees, and the patients were satisfied with the result of operation in 122. These painless knees showed no lateral thrust, and in the majority the deformity had been adequately corrected, with post-operative femoro-tibial angles (standing) ranging from 165 degrees to 174 degrees. Four of 28 knees with femoro-tibial angles of 175 degrees to 179 degrees, when measured one year after operation, showed recurrence of varus deformity three years after osteotomy. Preoperative ranges of knee motion were well maintained after osteotomy even when arthrotomy had also been undertaken. Intra-articular assessment in two patients, several years after operation, showed that the most degenerated portions of the articular surface were completely covered by a fibrocartilagenous layer, with no bare bone. High tibial osteotomy is most effective in osteoarthritic knees with varus deformity, when correction is made to a femoro-tibial angle (standing) of 170 degrees (10 degrees valgus).

  7. Mechanics and Hydrodynamics of Acrobatics and Aquabatics by Whales and Dolphins

    NASA Astrophysics Data System (ADS)

    Fish, Frank

    2017-11-01

    Cetaceans (whales, dolphins) are extremely energetic, fast swimming, and highly maneuverable in both water and air. Behaviors that cross the interface include breaching, porpoising, tail stands, and spin-leaps. The mechanics of breaching and porpoising entails propulsive movements of the caudal flukes to accelerate the animal vertically through the water surface to become airborne. Porpoising is beneficial to reduce the energetic cost of swimming at high speeds. Tail stands have a vertically oriented dolphin with half or more of its body out of the water. Bubble DPIV was used to quantify the propulsive force matching the weight of the animal supported above the water surface. The propulsive movements produced a jet flow and associated vorticity directed downward. Spin-leaps require a rapid vertical ascend from underwater by a rolling dolphin. Out of the water, the spin rate increases due to conservation of angular momentum and an imbalance between driving and resistive torques. The spin rate is associated with the moment of inertia of the animal's morphology. The physics of these high-energy maneuvers have engineering application for understanding ballistic performance across the air/water interface. Funded from ONR-MURI Grant N0001141410533.

  8. Lung volumes during sustained microgravity on Spacelab SLS-1

    NASA Technical Reports Server (NTRS)

    Elliott, Ann R.; Prisk, G. Kim; Guy, Harold J. B.; West, John B.

    1994-01-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (microgravity) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of microgravity exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (V9sub T)). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in microgravity and 32% in the supine posture. ERV was reduced by 10 - 20% in microgravity and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in microgravity but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of microgravity but returned to 1-G standing values within 72 h of microgravity exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During microgravity, V(sub T) decreased by 15% (approximately 90 ml), but supine V(sub T) was unchanged compared with preflight standing values. TLC decreased by approximately 8% during microgravity and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during microgravity are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

  9. Lung volumes during sustained microgravity on Spacelab SLS-1.

    PubMed

    Elliott, A R; Prisk, G K; Guy, H J; West, J B

    1994-10-01

    Gravity is known to influence the mechanical behavior of the lung and chest wall. However, the effect of sustained microgravity (mu G) on lung volumes has not been reported. Pulmonary function tests were performed by four subjects before, during, and after 9 days of mu G exposure. Ground measurements were made in standing and supine postures. Tests were performed using a bag-in-box-and-flowmeter system and a respiratory mass spectrometer. Measurements included functional residual capacity (FRC), expiratory reserve volume (ERV), residual volume (RV), inspiratory and expiratory vital capacities (IVC and EVC), and tidal volume (VT). Total lung capacity (TLC) was derived from the measured EVC and RV values. With preflight standing values as a comparison, FRC was significantly reduced by 15% (approximately 500 ml) in mu G and 32% in the supine posture. ERV was reduced by 10-20% in mu G and decreased by 64% in the supine posture. RV was significantly reduced by 18% (310 ml) in mu G but did not significantly change in the supine posture compared with standing. IVC and EVC were slightly reduced during the first 24 h of mu G but returned to 1-G standing values within 72 h of mu G exposure. IVC and EVC in the supine posture were significantly reduced by 12% compared with standing. During mu G, VT decreased by 15% (approximately 90 ml), but supine VT was unchanged compared with preflight standing values. TLC decreased by approximately 8% during mu G and in the supine posture compared with preflight standing. The reductions in FRC, ERV, and RV during mu G are probably due to the cranial shift of the diaphragm, an increase in intrathoracic blood volume, and more uniform alveolar expansion.

  10. Clinical experiences with axial deviation of the aryepiglottic folds in 52 racehorses.

    PubMed

    King, D S; Tulleners, E; Martin, B B; Parente, E J; Boston, R

    2001-01-01

    To describe the clinical findings in 52 racehorses with axial deviation of the aryepiglottic folds (ADAF) and to report outcome in 33 of these horses after either rest or transendoscopic laser excision of aryepiglottic fold tissue. Retrospective study. Racehorses admitted for high-speed treadmill (HST) evaluation of poor performance. Medical records and videotapes of resting and exercising videoendoscopic examinations were reviewed. Racing performance records and owner or trainer interviews, at least 1 year after HST examination, were used to compare results after either surgical management or rest in 33 horses with ADAF and no other upper-airway abnormalities. ADAF occurred in 6% of horses evaluated for poor performance. No breed or gender predisposition existed, but horses with ADAF were younger than the overall population evaluated on the HST. Of 52 horses with ADAF, 19 horses had at least one other upper-airway abnormality. There was no apparent association between ADAF and other causes of dynamic upper-respiratory obstruction. Surgical correction was successfully performed in standing or anesthetized horses without complications. When ADAF was the only upper-airway obstruction, 75% of horses that had surgery and 50% of rested horses had objective improvement in performance. Owners and trainers also perceived greater improvement in performance in horses that had surgery. Whereas surgical management of ADAF is recommended, clinical experience indicated that it is not required to resolve ADAF in all horses. However, owners and trainers of horses that had surgery were more satisfied with outcome than those with horses managed conservatively. Diagnosis of ADAF can only be made by videoendoscopic evaluation during high-speed exercise. Transendoscopic laser excision of the collapsing portion of the aryepiglottic folds can be performed safely in standing horses and results in resolution of airway obstruction and rapid return to training. Copyright 2001 by The American College of Veterinary Surgeons.

  11. Desk-based workers' perspectives on using sit-stand workstations: a qualitative analysis of the Stand@Work study.

    PubMed

    Chau, Josephine Y; Daley, Michelle; Srinivasan, Anu; Dunn, Scott; Bauman, Adrian E; van der Ploeg, Hidde P

    2014-07-25

    Prolonged sitting time has been identified as a health risk factor. Sit-stand workstations allow desk workers to alternate between sitting and standing throughout the working day, but not much is known about their acceptability and feasibility. Hence, the aim of this study was to qualitatively evaluate the acceptability, feasibility and perceptions of using sit-stand workstations in a group of desk-based office workers. This article describes the qualitative evaluation of the randomized controlled cross-over Stand@Work pilot trial. Participants were adult employees recruited from a non-government health agency in Sydney, Australia. The intervention involved using an Ergotron Workfit S sit-stand workstation for four weeks. After the four week intervention, participants shared their perceptions and experiences of using the sit-stand workstation in focus group interviews with 4-5 participants. Topics covered in the focus groups included patterns of workstation use, barriers and facilitators to standing while working, effects on work performance, physical impacts, and feasibility in the office. Focus group field notes and transcripts were analysed in an iterative process during and after the data collection period to identify the main concepts and themes. During nine 45-min focus groups, a total of 42 participants were interviewed. Participants were largely intrinsically motivated to try the sit-stand workstation, mostly because of curiosity to try something new, interest in potential health benefits, and the relevance to the participant's own and organisation's work. Most participants used the sit-stand workstation and three common usage patterns were identified: task-based routine, time-based routine, and no particular routine. Common barriers to sit-stand workstation use were working in an open plan office, and issues with sit-stand workstation design. Common facilitators of sit-stand workstation use were a supportive work environment conducive to standing, perceived physical health benefits, and perceived work benefits. When prompted, most participants indicated they were interested in using a sit-stand workstation in the future. The use of a sit-stand workstation in this group of desk-based office workers was generally perceived as acceptable and feasible. Future studies are needed to explore this in different desk-based work populations and settings.

  12. Experimental observation of standing wave effect in low-pressure very-high-frequency capacitive discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Yong-Xin; Gao, Fei; Liu, Jia

    2014-07-28

    Radial uniformity measurements of plasma density were carried out by using a floating double probe in a cylindrical (21 cm in electrode diameter) capacitive discharge reactor driven over a wide range of frequencies (27–220 MHz). At low rf power, a multiple-node structure of standing wave effect was observed at 130 MHz. The secondary density peak caused by the standing wave effect became pronounced and shifts toward the axis as the driving frequency further to increase, indicative of a much more shortened standing-wave wavelength. With increasing rf power, the secondary density peak shift toward the radial edge, namely, the standing-wave wavelength was increased,more » in good qualitative agreement with the previous theory and simulation results. At higher pressures and high frequencies, the rf power was primarily deposited at the periphery of the electrode, due to the fact that the waves were strongly damped as they propagated from the discharge edge into the center.« less

  13. Reduced clot debris size using standing waves formed via high intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Guo, Shifang; Du, Xuan; Wang, Xin; Lu, Shukuan; Shi, Aiwei; Xu, Shanshan; Bouakaz, Ayache; Wan, Mingxi

    2017-09-01

    The feasibility of utilizing high intensity focused ultrasound (HIFU) to induce thrombolysis has been demonstrated previously. However, clinical concerns still remain related to the clot debris produced via fragmentation of the original clot potentially being too large and hence occluding downstream vessels, causing hazardous emboli. This study investigates the use of standing wave fields formed via HIFU to disintegrate the thrombus while achieving a reduced clot debris size in vitro. The results showed that the average diameter of the clot debris calculated by volume percentage was smaller in the standing wave mode than in the travelling wave mode at identical ultrasound thrombolysis settings. Furthermore, the inertial cavitation dose was shown to be lower in the standing wave mode, while the estimated cavitation bubble size distribution was similar in both modes. These results show that a reduction of the clot debris size with standing waves may be attributed to the particle trapping of the acoustic potential well which contributed to particle fragmentation.

  14. Impact of sit-stand desks at work on energy expenditure and sedentary time: protocol for a feasibility study.

    PubMed

    Mantzari, Eleni; Wijndaele, Katrien; Brage, Soren; Griffin, Simon J; Marteau, Theresa M

    2016-01-01

    Prolonged sitting, an independent risk factor for disease development and premature mortality, is increasing in prevalence in high- and middle-income countries, with no signs of abating. Adults in such countries spend the largest proportion of their day in sedentary behaviour, most of which is accumulated at work. One promising method for reducing workplace sitting is the use of sit-stand desks. However, key uncertainties remain about this intervention, related to the quality of existing studies and a lack of focus on key outcomes, including energy expenditure. We are planning a randomised controlled trial to assess the impact of sit-stand desks at work on energy expenditure and sitting time in the short and longer term. To reduce the uncertainties related to the design of this trial, we propose a preliminary study to assess the feasibility and acceptability of the recruitment, allocation, measurement, retention and intervention procedures. Five hundred office-based employees from two companies in Cambridge, UK, will complete a survey to assess their interest in participating in a trial on the use of sit-stand desks at work. The workspaces of 100 of those interested in participating will be assessed for sit-stand desk installation suitability, and 20 participants will be randomised to either the use of sit-stand desks at work for 3 months or a waiting list control group. Energy expenditure and sitting time, measured via Actiheart and activPAL monitors, respectively, as well as cardio-metabolic and anthropometric outcomes and other outcomes relating to health and work performance, will be assessed in 10 randomly selected participants. All participants will also be interviewed about their experience of using the desks and participating in the study. The findings are expected to inform the design of a trial assessing the impact of sit-stand desks at work on short and longer term workplace sitting, taking into account their impact on energy expenditure and the extent to which their use has compensation effects outside the workplace. The findings from such a trial are expected to inform discussions regarding the potential of sit-stand desks at work to alleviate the harm to cardio-metabolic health arising from prolonged sitting. ISRCTN44827407.

  15. Ares Launch Vehicles Development Awakens Historic Test Stands at NASA's Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Dumbacher, Daniel L.; Burt, Richard K.

    2008-01-01

    This paper chronicles the rebirth of two national rocket testing assets located at NASA's Marshall Space Flight Center: the Dynamic Test Stand (also known as the Ground Vibration Test Stand) and the Static Test Stand (also known as the Main Propulsion Test Stand). It will touch on the historical significance of these special facilities, while introducing the requirements driving modifications for testing a new generation space transportation system, which is set to come on line after the Space Shuttle is retired in 2010. In many ways, America's journey to explore the Moon begins at the Marshall Center, which is developing the Ares I crew launch vehicle and the Ares V cargo launch vehicle, along with managing the Lunar Precursor Robotic Program and leading the Lunar Lander descent stage work, among other Constellation Program assignments. An important component of this work is housed in Marshall's Engineering Directorate, which manages more than 40 facilities capable of a full spectrum of rocket and space transportation technology testing - from small components to full-up engine systems. The engineers and technicians who operate these test facilities have more than a thousand years of combined experience in this highly specialized field. Marshall has one of the few government test groups in the United States with responsibility for the overall performance of a test program from conception to completion. The Test Laboratory has facilities dating back to the early 1960s, when the test stands needed for the Apollo Program and other scientific endeavors were commissioned and built along the Marshall Center's southern boundary, with logistics access by air, railroad, and barge or boat on the Tennessee River. NASA and its industry partners are designing and developing a new human-rated system based on the requirements for safe, reliable, and cost-effective transportation solutions. Given below are summaries of the Dynamic Test Stand and the Static Test Stand capabilities, along with an introduction to the new missions that these sleeping giants will be fulfilling as NASA readies the Ares I for service in the 2015 timeframe, and plans the development work for fielding the Ares V late next decade (fig. 1). Validating modern computer design models and techniques requires the sorts of data that can only be generated by these one-of-a-kind facilities.

  16. Breaking up workplace sitting time with intermittent standing bouts improves fatigue and musculoskeletal discomfort in overweight/obese office workers.

    PubMed

    Thorp, Alicia A; Kingwell, Bronwyn A; Owen, Neville; Dunstan, David W

    2014-11-01

    To examine whether the introduction of intermittent standing bouts during the workday using a height-adjustable workstation can improve subjective levels of fatigue, musculoskeletal discomfort and work productivity relative to seated work. Overweight/obese office workers (n=23; age 48.2±7.9 years, body mass index 29.6±4 kg/m(2)) undertook two, 5-day experimental conditions in an equal, randomised (1:1) order. In a simulated office environment, participants performed their usual occupational tasks for 8 h/day in a: seated work posture (SIT condition); or interchanging between a standing and seated work posture every 30 min using an electric, height-adjustable workstation (STAND-SIT condition). Self-administered questionnaires measuring fatigue, musculoskeletal discomfort and work productivity were performed on day 5 of each experimental condition. Participants' total fatigue score was significantly higher during the SIT condition (mean 67.8 (95% CI 58.8 to 76.7)) compared with the STAND-SIT condition (52.7 (43.8 to 61.5); p<0.001). Lower back musculoskeletal discomfort was significantly reduced during the STAND-SIT condition compared with the SIT condition (31.8% reduction; p=0.03). Despite concentration/focus being significantly higher during the SIT condition (p=0.006), there was a trend towards improved overall work productivity in favour of the STAND-SIT condition (p=0.053). Transitioning from a seated to a standing work posture every 30 min across the workday, relative to seated work, led to a significant reduction in fatigue levels and lower back discomfort in overweight/obese office workers, while maintaining work productivity. Future investigations should be directed at understanding whether sustained use of height-adjustable workstations promote concentration and productivity at work. ACTRN12611000632998. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  17. Inflammation and nutritional status as predictors of physical performance and strength loss during hospitalization.

    PubMed

    Rossi, A P; Zanandrea, V; Zoico, E; Zanardo, M; Caliari, C; Confente, S; Gabriele, S; Mazzali, G; Fantin, F; Zamboni, M

    2016-12-01

    The aim of this study was to examine changes in physical performance and handgrip strength during hospitalization as well as to evaluate their interrelationship with inflammatory and nutritional status. Data were available on 302 elderly patients with a mean age of 80.83±7.14 years. Handgrip strength, gait speed and chair-stand test were assessed at admission and before discharge. In all subjects, serum CRP values and Mini Nutritional Assessment scores were also evaluated. The risk of worsening in chair-stand test performance was 4.2 (95% confidence interval (CI): 1.574-11.310) for subjects with simultaneous presence of malnutrition and CRP⩾50 and 3.3 mg/dl (95% CI: 1.127-9.423) for subjects with CRP⩾50 mg/l not malnourished in comparison with subjects with Mini Nutritional Assessment (MNA)⩾24 and CRP⩽10 mg/l. The risk of handgrip strength loss was 8.8 (95% CI: 3.545-21.662) in subjects with simultaneous presence of malnutrition and CRP⩾50 and 2.9  mg/dl (95% CI: 1.223-6.783) in subjects with CRP⩾50 mg/l not malnourished in comparison with subjects with MNA⩾24 and CRP⩽10 mg/l. Simultaneous presence of high CRP values and malnutrition determines an additive effect on muscle strength loss and physical performance.

  18. Detection of forest stand-level spatial structure in ectomycorrhizal fungal communities

    Treesearch

    Erik A. Lilleskov; Thomas D. Bruns; Thomas R. Horton; D. Lee Taylor; Paul Grogan

    2004-01-01

    Ectomycorrhizal fungal (EMF) communities are highly diverse at the stand level. To begin to understand what might lead to such diversity, and to improve sampling designs, we investigated the spatial structure of these communities. We used EMF community data from a number of studies carried out in seven mature and one recently fire-initiated forest stand. We applied...

  19. Crop-tree release thinning in 65-year-old commercial cherry-maple stands (5-year results)

    Treesearch

    H. Clay Smith; Gary W. Miller; Neil I. Lamson

    1994-01-01

    Crop-tree release was applied to a 65-year-old cherry-maple stand in north central West Virginia. Criteria were developed for selecting crop trees for high quality sawtimber and veneer products. Five-year stand growth, mortality, and ingrowth using basal areas, volume, relative density, and number of trees were discussed for the treatments.

  20. Determinants of tree quality and lumber value in natural uneven-aged southern pine stands

    Treesearch

    Jeffrey P. Prestemon; Joseph Buongiorno

    2000-01-01

    An ordered-probit model was developed to predict tree grade from tree- and stand-level variables, some of which could be changed by management. Applied to uneven-aged mixed loblolly (Pinus taeda L.) - shortleaf pine (Pinus echinata Mill.) stands, the model showed that the grade of pine trees was highly correlated with tree diameter...

Top