  1. Determination of Unknown Concentrations of Sodium Acetate Using the Method of Standard Addition and Proton NMR: An Experiment for the Undergraduate Analytical Chemistry Laboratory

    ERIC Educational Resources Information Center

    Rajabzadeh, Massy

    2012-01-01

    In this experiment, students learn how to find the unknown concentration of sodium acetate using both the graphical treatment of standard addition and the standard addition equation. In the graphical treatment of standard addition, the peak area of the methyl peak in each of the sodium acetate standard solutions is found by integration using…

  2. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    ERIC Educational Resources Information Center

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  3. External Standards or Standard Addition? Selecting and Validating a Method of Standardization

    NASA Astrophysics Data System (ADS)

    Harvey, David T.

    2002-05-01

    A common feature of many problem-based laboratories in analytical chemistry is a lengthy independent project involving the analysis of "real-world" samples. Students research the literature, adapting and developing a method suitable for their analyte, sample matrix, and problem scenario. Because these projects encompass the complete analytical process, students must consider issues such as obtaining a representative sample, selecting a method of analysis, developing a suitable standardization, validating results, and implementing appropriate quality assessment/quality control practices. Most textbooks and monographs suitable for an undergraduate course in analytical chemistry, however, provide only limited coverage of these important topics. The need for short laboratory experiments emphasizing important facets of method development, such as selecting a method of standardization, is evident. The experiment reported here, which is suitable for an introductory course in analytical chemistry, illustrates the importance of matrix effects when selecting a method of standardization. Students also learn how a spike recovery is used to validate an analytical method, and obtain a practical experience in the difference between performing an external standardization and a standard addition.

  4. Optimal Multicomponent Analysis Using the Generalized Standard Addition Method.

    ERIC Educational Resources Information Center

    Raymond, Margaret; And Others

    1983-01-01

    Describes an experiment on the simultaneous determination of chromium and magnesium by spectophotometry modified to include the Generalized Standard Addition Method computer program, a multivariate calibration method that provides optimal multicomponent analysis in the presence of interference and matrix effects. Provides instructions for…

  5. Magnetic Field Experiment Data Analysis System

    NASA Technical Reports Server (NTRS)

    Holland, D. B.; Zanetti, L. J.; Suther, L. L.; Potemra, T. A.; Anderson, B. J.

    1995-01-01

    The Johns Hopkins University Applied Physics Laboratory (JHU/APL) Magnetic Field Experiment Data Analysis System (MFEDAS) has been developed to process and analyze satellite magnetic field experiment data from the TRIAD, MAGSAT, AMPTE/CCE, Viking, Polar BEAR, DMSP, HILAT, UARS, and Freja satellites. The MFEDAS provides extensive data management and analysis capabilities. The system is based on standard data structures and a standard user interface. The MFEDAS has two major elements: (1) a set of satellite unique telemetry processing programs for uniform and rapid conversion of the raw data to a standard format and (2) the program Magplot which has file handling, data analysis, and data display sections. This system is an example of software reuse, allowing new data sets and software extensions to be added in a cost effective and timely manner. Future additions to the system will include the addition of standard format file import routines, modification of the display routines to use a commercial graphics package based on X-Window protocols, and a generic utility for telemetry data access and conversion.

  6. [FADCC in NIHS for prior consultation system of application of food additives].

    PubMed

    Akiyama, Hiroshi; Sato, Kyoko

    2015-01-01

    An increasing number of inquiries about application of food additives have been made from businesses in and outside Japan. The Ministry of Health, Labour and Welfare (MHLW) is requested to expedite the procedure for designation and revision of use standards. In June 2014, the MHLW set up a center for consultation on application concerning food additives (Food Additive Designation Consultation Center, FADCC) in the National Institute of Health Sciences, aiming to smoothly and expeditiously handle clerical work for designation or revision of the use standards. FADCC gives advice on how to prepare documents on the information such as physicochemical characteristics, effectiveness, safety, daily intake and use standards, based on actual cases and experience.

  7. Standard-resolution TOVS observations for the FIRE/SRB Wisconsin experiment region from October 9 through November 2, 1986

    NASA Technical Reports Server (NTRS)

    Whitlock, Charles H.; Lecroy, Stuart R.; Darnell, Wayne L.

    1987-01-01

    Maps and concise tables are presented which show TIROS Operational Vertical Sounder (TOVS) box centroid locations, box size, and vertical sounding products from the NOAA-6 and -9 satellites for the FIRE/SRB (First ISCCP Regional Experiment/Surface Radiation Budget) Wisconsin experiment region during October 9 through November 2, 1986. In addition to the operational standard products, relative reflectance is calculated and presented based on values from HIRS/2 Band 20 measurements.

  8. Determination of Calcium in Cereal with Flame Atomic Absorption Spectroscopy: An Experiment for a Quantitative Methods of Analysis Course

    ERIC Educational Resources Information Center

    Bazzi, Ali; Kreuz, Bette; Fischer, Jeffrey

    2004-01-01

    An experiment for determination of calcium in cereal using two-increment standard addition method in conjunction with flame atomic absorption spectroscopy (FAAS) is demonstrated. The experiment is intended to introduce students to the principles of atomic absorption spectroscopy giving them hands on experience using quantitative methods of…

  9. The Shell Seeker: What Is the Quantity of Shell in the Lido di Venezia Sand? A Calibration DRIFTS Experiment

    ERIC Educational Resources Information Center

    Pezzolo, Alessandra De Lorenzi

    2011-01-01

    In this experiment, students are given a fanciful application of the standard addition method to evaluate the approximate quantity of the shell component in a sample of sand collected on the Lido di Venezia seashore. Several diffuse reflectance infrared Fourier transform (DRIFT) spectra are recorded from a sand sample before and after addition of…

  10. Cost-effectiveness of omalizumab add-on to standard-of-care therapy in patients with uncontrolled severe allergic asthma in a Brazilian healthcare setting.

    PubMed

    Suzuki, Cibele; Lopes da Silva, Nilceia; Kumar, Praveen; Pathak, Purnima; Ong, Siew Hwa

    2017-08-01

    Omalizumab add-on to standard-of-care therapy has proven to be efficacious in severe asthma patients for whom exacerbations cannot be controlled otherwise. Moreover, evidence from different healthcare settings suggests reduced healthcare resource utilization with omalizumab. Based on these findings, this study aimed to assess the cost-effectiveness of the addition of omalizumab to standard-of-care therapy in patients with uncontrolled severe allergic asthma in a Brazilian healthcare setting. A previously published Markov model was adapted using Brazil-specific unit costs to compare the costs and outcomes of the addition of omalizumab to standard-of-care therapy vs standard-of-care therapy alone. Model inputs were largely based on the eXpeRience study. Costs and health outcomes were calculated for lifetime-years and were annually discounted at 5%. Both one-way and probabilistic sensitivity analyses were performed. An additional cost of R$280,400 for 5.20 additional quality-adjusted life-years was estimated with the addition of omalizumab to standard-of-care therapy, resulting in an incremental cost-effectiveness ratio of R$53,890. One-way sensitivity analysis indicated that discount rates, standard-of-care therapy exacerbation rates, and exacerbation-related mortality rates had the largest impact on incremental cost-effectiveness ratios. Assumptions of lifetime treatment adherence and rate of future exacerbations, independent of previous events, might affect the findings. The lack of Brazilian patients in the eXpeRience study may affect the findings, although sample size and baseline characteristics suggest that the modeled population closely resembles Brazilian severe allergic asthma patients. Results indicate that omalizumab as an add-on therapy is more cost-effective than standard-of-care therapy alone for Brazilian patients with uncontrolled severe allergic asthma, based on the World Health Organization's cost-effectiveness threshold of up to 3-times the gross domestic product.

  11. Testing of the palatability of Thymus vulgaris L. and Origanum vulgare L. as flavouring feed additive for weaner pigs on the basis of a choice experiment.

    PubMed

    Jugl-Chizzola, Martina; Ungerhofer, Elisabeth; Gabler, Cornelia; Hagmüller, Werner; Chizzola, Remigius; Zitterl-Eglseer, Karin; Franz, Chlodwig

    2006-01-01

    The objective of the study at hand was to investigate within the framework of a pilot project the preference of weaner pigs for either an ad libitum standard feed with thyme or oregano herb as flavouring additive or an ad libitum standard feed without any herbal additive. Thyme or oregano herbs or a combination of both were offered in two different concentrations each (1% and 0.1%) as additive (experimental diets) in standard diet in comparison to the latter without herbal additive (control diet) free of choice. The dosage of the two herbs in terms of total essential oil(s) in the feeds used in the study was 0.02% or 0.002% (v/w), which was equivalent to 1% or 0.1% herbs in the mixture, respectively. A Latin square according to Williams (1949) was used with 6 groups in order to record possible differences in feed intake. All experimental diets aside from that mixed with 0.1% thyme herb were, in comparison to the control diet, significantly less ingested. Where the weanling was given the choice, it did not choose feed with any flavouring additive. Further studies aimed at assessing the use of herbs as aroma additive in the form of a choice experiment are recommended.

  12. Beyond standard model searches in the MiniBooNE experiment

    DOE PAGES

    Katori, Teppei; Conrad, Janet M.

    2014-08-05

    Tmore » he MiniBooNE experiment has contributed substantially to beyond standard model searches in the neutrino sector. he experiment was originally designed to test the Δ m 2 ~ 1 eV 2 region of the sterile neutrino hypothesis by observing ν e ( ν - e ) charged current quasielastic signals from a ν μ ( ν - μ ) beam. MiniBooNE observed excesses of ν e and ν - e candidate events in neutrino and antineutrino mode, respectively. o date, these excesses have not been explained within the neutrino standard model ( ν SM); the standard model extended for three massive neutrinos. Confirmation is required by future experiments such as MicroBooNE. MiniBooNE also provided an opportunity for precision studies of Lorentz violation. he results set strict limits for the first time on several parameters of the standard-model extension, the generic formalism for considering Lorentz violation. Most recently, an extension to MiniBooNE running, with a beam tuned in beam-dump mode, is being performed to search for dark sector particles. In addition, this review describes these studies, demonstrating that short baseline neutrino experiments are rich environments in new physics searches.« less

  13. Minimum Information about a Spinal Cord Injury Experiment: A Proposed Reporting Standard for Spinal Cord Injury Experiments

    PubMed Central

    Ferguson, Adam R.; Popovich, Phillip G.; Xu, Xiao-Ming; Snow, Diane M.; Igarashi, Michihiro; Beattie, Christine E.; Bixby, John L.

    2014-01-01

    Abstract The lack of reproducibility in many areas of experimental science has a number of causes, including a lack of transparency and precision in the description of experimental approaches. This has far-reaching consequences, including wasted resources and slowing of progress. Additionally, the large number of laboratories around the world publishing articles on a given topic make it difficult, if not impossible, for individual researchers to read all of the relevant literature. Consequently, centralized databases are needed to facilitate the generation of new hypotheses for testing. One strategy to improve transparency in experimental description, and to allow the development of frameworks for computer-readable knowledge repositories, is the adoption of uniform reporting standards, such as common data elements (data elements used in multiple clinical studies) and minimum information standards. This article describes a minimum information standard for spinal cord injury (SCI) experiments, its major elements, and the approaches used to develop it. Transparent reporting standards for experiments using animal models of human SCI aim to reduce inherent bias and increase experimental value. PMID:24870067

  14. Gas Pressure-Drop Experiment

    ERIC Educational Resources Information Center

    Luyben, William L.; Tuzla, Kemal

    2010-01-01

    Most chemical engineering undergraduate laboratories have fluid mechanics experiments in which pressure drops through pipes are measured over a range of Reynolds numbers. The standard fluid is liquid water, which is essentially incompressible. Since density is constant, pressure drop does not depend on the pressure in the pipe. In addition, flow…

  15. Patient Protection and Affordable Care Act; annual eligibility redeterminations for exchange participation and insurance affordability programs; health insurance issuer standards under the Affordable Care Act, including standards related to exchanges. Final rule.

    PubMed

    2014-09-05

    This final rule specifies additional options for annual eligibility redeterminations and renewal and re-enrollment notice requirements for qualified health plans offered through the Exchange, beginning with annual redeterminations for coverage for benefit year 2015. This final rule provides additional flexibility for Exchanges, including the ability to propose unique approaches that meet the specific needs of their state, while streamlining the consumer experience.

  16. Edesign: Primer and Enhanced Internal Probe Design Tool for Quantitative PCR Experiments and Genotyping Assays.

    PubMed

    Kimura, Yasumasa; Soma, Takahiro; Kasahara, Naoko; Delobel, Diane; Hanami, Takeshi; Tanaka, Yuki; de Hoon, Michiel J L; Hayashizaki, Yoshihide; Usui, Kengo; Harbers, Matthias

    2016-01-01

    Analytical PCR experiments preferably use internal probes for monitoring the amplification reaction and specific detection of the amplicon. Such internal probes have to be designed in close context with the amplification primers, and may require additional considerations for the detection of genetic variations. Here we describe Edesign, a new online and stand-alone tool for designing sets of PCR primers together with an internal probe for conducting quantitative real-time PCR (qPCR) and genotypic experiments. Edesign can be used for selecting standard DNA oligonucleotides like for instance TaqMan probes, but has been further extended with new functions and enhanced design features for Eprobes. Eprobes, with their single thiazole orange-labelled nucleotide, allow for highly sensitive genotypic assays because of their higher DNA binding affinity as compared to standard DNA oligonucleotides. Using new thermodynamic parameters, Edesign considers unique features of Eprobes during primer and probe design for establishing qPCR experiments and genotyping by melting curve analysis. Additional functions in Edesign allow probe design for effective discrimination between wild-type sequences and genetic variations either using standard DNA oligonucleotides or Eprobes. Edesign can be freely accessed online at http://www.dnaform.com/edesign2/, and the source code is available for download.

  17. Edesign: Primer and Enhanced Internal Probe Design Tool for Quantitative PCR Experiments and Genotyping Assays

    PubMed Central

    Kasahara, Naoko; Delobel, Diane; Hanami, Takeshi; Tanaka, Yuki; de Hoon, Michiel J. L.; Hayashizaki, Yoshihide; Usui, Kengo; Harbers, Matthias

    2016-01-01

    Analytical PCR experiments preferably use internal probes for monitoring the amplification reaction and specific detection of the amplicon. Such internal probes have to be designed in close context with the amplification primers, and may require additional considerations for the detection of genetic variations. Here we describe Edesign, a new online and stand-alone tool for designing sets of PCR primers together with an internal probe for conducting quantitative real-time PCR (qPCR) and genotypic experiments. Edesign can be used for selecting standard DNA oligonucleotides like for instance TaqMan probes, but has been further extended with new functions and enhanced design features for Eprobes. Eprobes, with their single thiazole orange-labelled nucleotide, allow for highly sensitive genotypic assays because of their higher DNA binding affinity as compared to standard DNA oligonucleotides. Using new thermodynamic parameters, Edesign considers unique features of Eprobes during primer and probe design for establishing qPCR experiments and genotyping by melting curve analysis. Additional functions in Edesign allow probe design for effective discrimination between wild-type sequences and genetic variations either using standard DNA oligonucleotides or Eprobes. Edesign can be freely accessed online at http://www.dnaform.com/edesign2/, and the source code is available for download. PMID:26863543

  18. Little Green Man Physics

    ERIC Educational Resources Information Center

    Higbie, J.

    2013-01-01

    We have frequently enhanced our department's laboratory experiment involving standing transverse waves in a taut horizontal cord. In addition to the standard experiment, students in these labs investigate the surprising concept that the acceleration of a pulse in a chain hanging vertically is a constant and is equal to half the acceleration…

  19. Therapy of umbilical hernia during laparoscopic cholecystectomy.

    PubMed

    Zoricić, Ivan; Vukusić, Darko; Rasić, Zarko; Schwarz, Dragan; Sever, Marko

    2013-09-01

    The aim of this study is to show our experience with umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, both in the same act. During last 10 years we operated 89 patients with cholecystitis and pre-existing umbilical hernia. In 61 of them we performed standard laparoscopic cholecystectomy and additional sutures of abdominal wall, and in 28 patients we performed in the same act laparoscopic cholecystectomy and herniorrhaphy of umbilical hernia. We observed incidence of postoperative herniation, and compared patients recovery after herniorrhaphy combined with laparoscopic cholecystectomy in the same act, and patients after standard laparoscopic cholecystectomy and additional sutures of abdominal wall. Patients, who had in the same time umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, shown better postoperative recovery and lower incidence of postoperative umbilical hernias then patients with standard laparoscopic cholecystectomy and additional abdominal wall sutures.

  20. [Experiences in half-side treatment with tar additive to cignolin-salicylic-acid-white-vaseline therapy of psoriasis vulgaris].

    PubMed

    Schulze, H J; Steigleder, G K

    1984-05-15

    As shown in bilateral comparison studies addition of crude coal tar (T) to standard antipsoriatic therapy with dithranol and salicylic acid in white petrolatum (CVS) diminished the dithranol-irritation; consequently, accelerated application of increasing dithranol-concentrations shortened the duration of TCSV -therapy.

  1. ATLAS particle detector CSC ROD software design and implementation, and, Addition of K physics to chi-squared analysis of FDQM

    NASA Astrophysics Data System (ADS)

    Hawkins, Donovan Lee

    In this thesis I present a software framework for use on the ATLAS muon CSC readout driver. This C++ framework uses plug-in Decoders incorporating hand-optimized assembly language routines to perform sparsification and data formatting. The software is designed with both flexibility and performance in mind, and runs on a custom 9U VME board using Texas Instruments TMS360C6203 digital signal processors. I describe the requirements of the software, the methods used in its design, and the results of testing the software with simulated data. I also present modifications to a chi-squared analysis of the Standard Model and Four Down Quark Model (FDQM) originally done by Dr. Dennis Silverman. The addition of four new experiments to the analysis has little effect on the Standard Model but provides important new restrictions on the FDQM. The method used to incorporate these new experiments is presented, and the consequences of their addition are reviewed.

  2. Searching for θ 13 at Daya Bay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giedt, Joel; Napolitano, James

    2015-06-08

    An experiment has been carried out by the Daya Bay Collaboration to measure the neutrino mixing angle θ 13. In addition, the grant has supported research into lattice field theory beyond the standard model.

  3. On the g/2 Acceleration of a Pulse in a Vertical Chain

    ERIC Educational Resources Information Center

    Foster, Theodore; van Wyngaarden, Willem; Cary, Arthur; Mottmann, John

    2013-01-01

    We have frequently enhanced our department's laboratory experiment involving standing transverse waves in a taut horizontal cord. In addition to the standard experiment, students in these labs investigate the surprising concept that the acceleration of a pulse in a chain hanging vertically is a constant and is equal to half the acceleration…

  4. The Seventh SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-7), March 1999

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); McLean, Scott; Sherman, Jennifer; Small, Mark; Lazin, Gordana; Zibordi, Giuseppe; Brown, James W.; McClain, Charles R. (Technical Monitor)

    2002-01-01

    This report documents the scientific activities during the seventh SeaWiFS Intercalibration Round-Robin Experiment (SIRREX-7) held at Satlantic, Inc. (Halifax, Canada). The overall objective of SIRREX-7 was to determine the uncertainties of radiometric calibrations and measurements at a single calibration facility. Specifically, this involved the estimation of the uncertainties in a) lamp standards, b) plaque standards (including the uncertainties associated with plaque illumination non-uniformity), c) radiance calibrations, and d) irradiance calibrations. The investigation of the uncertainties in lamp standards included a comparison between a calibration of a new FEL by the National Institute of Standards and Technology (NIST) and Optronic Laboratories, Inc. In addition, the rotation and polarization sensitivity of radiometers were determined, and a procedure for transferring an absolute calibration to portable light sources was defined and executed.

  5. Elementary Particle Physics Experiment at the University of Massachusetts, Amherst

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brau, Benjamin; Dallapiccola, Carlo; Willocq, Stephane

    2013-07-30

    In this progress report we summarize the activities of the University of Massachusetts- Amherst group for the three years of this research project. We are fully engaged in research at the energy frontier with the ATLAS experiment at the CERN Large Hadron Collider. We have made leading contributions in software development and performance studies for the ATLAS Muon Spectrometer, as well as on physics analysis with an emphasis on Standard Model measurements and searches for physics beyond the Standard Model. In addition, we have increased our contributions to the Muon Spectrometer New Small Wheel upgrade project.

  6. BeBot: A Modular Mobile Miniature Robot Platform Supporting Hardware Reconfiguration and Multi-standard Communication

    NASA Astrophysics Data System (ADS)

    Herbrechtsmeier, Stefan; Witkowski, Ulf; Rückert, Ulrich

    Mobile robots become more and more important in current research and education. Especially small ’on the table’ experiments attract interest, because they need no additional or special laboratory equipments. In this context platforms are desirable which are small, simple to access and relatively easy to program. An additional powerful information processing unit is advantageous to simplify the implementation of algorithm and the porting of software from desktop computers to the robot platform. In this paper we present a new versatile miniature robot that can be ideally used for research and education. The small size of the robot of about 9 cm edge length, its robust drive and its modular structure make the robot a general device for single and multi-robot experiments executed ’on the table’. For programming and evaluation the robot can be wirelessly connected via Bluetooth or WiFi. The operating system of the robot is based on the standard Linux kernel and the GNU C standard library. A player/stage model eases software development and testing.

  7. Experimental Anomalies in Neutrino Physics

    NASA Astrophysics Data System (ADS)

    Palamara, Ornella

    2014-03-01

    In recent years, experimental anomalies ranging in significance (2.8-3.8 σ) have been reported from a variety of experiments studying neutrinos over baselines less than 1 km. Results from the LSND and MiniBooNE short-baseline νe /νe appearance experiments show anomalies which cannot be described by oscillations between the three standard model neutrinos (the ``LSND anomaly''). In addition, a re-analysis of the anti-neutrino flux produced by nuclear power reactors has led to an apparent deficit in νe event rates in a number of reactor experiments (the ``reactor anomaly''). Similarly, calibration runs using 51Cr and 37Ar radioactive sources in the Gallium solar neutrino experiments GALLEX and SAGE have shown an unexplained deficit in the electron neutrino event rate over very short distances (the ``Gallium anomaly''). The puzzling results from these experiments, which together may suggest the existence of physics beyond the Standard Model and hint at exciting new physics, including the possibility of additional low-mass sterile neutrino states, have raised the interest in the community for new experimental efforts that could eventually solve this puzzle. Definitive evidence for sterile neutrinos would be a revolutionary discovery, with implications for particle physics as well as cosmology. Proposals to address these signals by employing accelerator, reactor and radioactive source experiments are in the planning stages or underway worldwide. In this talk some of these will be reviewed, with emphasis on the accelerator programs.

  8. An Update to the EARTHTIME Argon Intercalibration Pipette System (APIS): Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Deino, A. L.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.

    2015-12-01

    Background: An initial 40Ar/39Ar inter-calibration experiment, using two of the most commonly used 40Ar/39Ar mineral standards, Fish Canyon (FC, ~28.2 Ma) and Alder Creek (AC, ~1.2 Ma) sanidines, revealed significant inter-laboratory inconsistencies. The reported ages for the AC sanidines range from 1.173 to 1.200 Ma (FC 28.02) (±~2%), ~4 times greater than the reported precisions. These experiments have motivated the 40Ar/39Ar community to reevaluate procedures and subsequent informal lab intercalibrations experiments are in better agreement, but discrepancies remain that need to be addressed. Experiment: In an effort to isolate the causes of these inconsistencies, an Argon Intercalibration Pipette System (APIS) was designed and constructed. The APIS system consists of three gas canisters; one containing atmospheric Ar and the other two canisters contain 40Ar/39Ar ratios that represent FC and AC. The volumes of the pipettes, bulbs and manifold are determined to within 0.4% and both systems were initially filled to the same pressure with Ar standard gases. Each canister has 4x10-10 moles of 40Ar, is equipped with a 0.1, 0.2 and 0.4 cc pipettes and can deliver increments from 0.1-0.7 cc. APIS-1 was designated as the traveling unit that is brought to participating labs, APIS-2 is the reserve/master standard. Early Results and Impressions: APIS-1 has been to four labs (Rutgers, LDEO, New Mexico Tech, and BGC) and is heading to ASU. Early APIS experimental data indicate that the inter-laboratory 40Ar/39Ar age results can meet or exceed the EARTHTIME goal of ±1‰ precision. The inter-laboratory comparisons are ongoing, and will include additional laboratories of opportunity. Lastly, the development of additional mineral standards that "fill in" the age gaps between the existing mineral standards would significantly improve attempting to achieve interlaboratory agreement at the ±1‰ level

  9. Laser Propulsion Standardization Issues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scharring, Stefan; Eckel, Hans-Albert; Roeser, Hans-Peter

    It is a relevant issue in the research on laser propulsion that experimental results are treated seriously and that meaningful scientific comparison is possible between groups using different equipment and measurement techniques. However, critical aspects of experimental measurements are sparsely addressed in the literature. In addition, few studies so far have the benefit of independent confirmation by other laser propulsion groups. In this paper, we recommend several approaches towards standardization of published laser propulsion experiments. Such standards are particularly important for the measurement of laser ablation pulse energy, laser spot area, imparted impulse or thrust, and mass removal during ablation.more » Related examples are presented from experiences of an actual scientific cooperation between NU and DLR. On the basis of a given standardization, researchers may better understand and contribute their findings more clearly in the future, and compare those findings confidently with those already published in the laser propulsion literature. Relevant ISO standards are analyzed, and revised formats are recommended for application to laser propulsion studies.« less

  10. Proposed minimum reporting standards for chemical analysis Chemical Analysis Working Group (CAWG) Metabolomics Standards Initiative (MSI)

    PubMed Central

    Amberg, Alexander; Barrett, Dave; Beale, Michael H.; Beger, Richard; Daykin, Clare A.; Fan, Teresa W.-M.; Fiehn, Oliver; Goodacre, Royston; Griffin, Julian L.; Hankemeier, Thomas; Hardy, Nigel; Harnly, James; Higashi, Richard; Kopka, Joachim; Lane, Andrew N.; Lindon, John C.; Marriott, Philip; Nicholls, Andrew W.; Reily, Michael D.; Thaden, John J.; Viant, Mark R.

    2013-01-01

    There is a general consensus that supports the need for standardized reporting of metadata or information describing large-scale metabolomics and other functional genomics data sets. Reporting of standard metadata provides a biological and empirical context for the data, facilitates experimental replication, and enables the re-interrogation and comparison of data by others. Accordingly, the Metabolomics Standards Initiative is building a general consensus concerning the minimum reporting standards for metabolomics experiments of which the Chemical Analysis Working Group (CAWG) is a member of this community effort. This article proposes the minimum reporting standards related to the chemical analysis aspects of metabolomics experiments including: sample preparation, experimental analysis, quality control, metabolite identification, and data pre-processing. These minimum standards currently focus mostly upon mass spectrometry and nuclear magnetic resonance spectroscopy due to the popularity of these techniques in metabolomics. However, additional input concerning other techniques is welcomed and can be provided via the CAWG on-line discussion forum at http://msi-workgroups.sourceforge.net/ or http://Msi-workgroups-feedback@lists.sourceforge.net. Further, community input related to this document can also be provided via this electronic forum. PMID:24039616

  11. Experiences with Ada in an embedded system

    NASA Technical Reports Server (NTRS)

    Labaugh, Robert J.

    1988-01-01

    Recent experiences with using Ada in a real time environment are described. The application was the control system for an experimental robotic arm. The objectives of the effort were to experiment with developing embedded applications in Ada, evaluating the suitability of the language for the application, and determining the performance of the system. Additional objectives were to develop a control system based on the NASA/NBS Standard Reference Model for Telerobot Control System Architecture (NASREM) in Ada, and to experiment with the control laws and how to incorporate them into the NASREM architecture.

  12. Study of sleeping in a chemical protective ensemble in a warfare environment. Final report 26 Aug 81-2 Dec 82

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cacioppo, G.M.; Annis, J.F.

    1982-12-01

    Experiments were performed to evaluate the quality of sleep experienced by individuals wearing different chemical protective ensembles (CPE). A series of seven experiments were conducted in which two test subjects slept overnight in an environmentally controlled room while wearing either pajamas (control ensemble) or one of three different CPEs. The three CPEs tested were: the standard West German ground crew ensemble, an ensemble comprised of a combination of equipment of which the Canadian chemical protective coverall was the principal item of clothing, and the U.S. Army standard ground crew ensemble Body temperatures, sleep records, and other physiological measurements were monitoredmore » overnight and form the basis of the objective evaluation. Subjective data were collected by an experiment monitor who kept the test participants under constant observation. Additionally, the participants were required to complete a standard debriefing questionnaire form each post-experiment morning. Because of the limited scope of the experiment, statistical analysis was not appropriate. However, both the objective and subjective data reflected consistent trends and allow confidence in the assessment that current U.S. and NATO CPE combinations provide for adequate sleep quality.« less

  13. "It can be challenging, it can be scary, it can be gratifying": Obstetricians' narratives of negotiating patient choice, clinical experience, and standards of care in decision-making.

    PubMed

    Diamond-Brown, Lauren

    2018-05-01

    This paper examines obstetricians' perceptions of standards of care and patient-centered care in clinical decision-making in childbirth. Patient-centered care and standardization of medicine are two social movements that seek to change how physicians make clinical decisions. Sociologists question if these limit physician discretion and weaken their social power; the degree to which this occurs in everyday practice is up for debate. Of additional concern is how physicians deal with observed tensions between these ideals. These questions are answered through in-depth interviews with 50 self-selected obstetricians from Massachusetts, Louisiana, and Vermont collected between 2013 and 2015. Interview data was analyzed using a grounded theory and template approach. The author problematizes obstetricians' attitudes about standards of care and shared decision-making, mechanisms that encourage or discourage these approaches to decision-making, and how obstetricians negotiate tensions between patient choice, clinical experience, and standards. The key findings are that most obstetricians feel they have the authority to interpret the appropriateness of standards and patient choice on a case-by-case basis. They feel empowered and/or constrained by pressures to practice patient-centered care and standards depending upon their style of practice and the organizational context. Following standards of care is encouraged through organizational mechanisms such as pressure from colleagues, malpractice threat, hospital policy, and payer restrictions. Practicing shared decision-making is challenged when the patient wants something that violates the physician's clinical experience and/or standards of care. When obstetricians prioritize patient choice over experience and/or standards this is done for moral reasons, less so because of organizational pressures. These findings have implications for theorizing the social status of medical professionals, understanding how physicians deal with tensions between standardized and individualized ideals in medicine, and illuminating the way obstetricians interpret power in the physician-patient relationship. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Results and Systematic Studies of the UCN Lifetime Experiment at NIST

    NASA Astrophysics Data System (ADS)

    Huffer, Craig Reeves

    The neutron beta-decay lifetime is important in understanding weak interactions in the framework of the Standard Model, and it is an input to nuclear astrophysics and Big Bang Nucleosynthesis. Current measurements of the neutron beta-decay lifetime disagree, which has motivated additional experiments that are sensitive to different sets of systematic effects. An effort continues at the NIST Center for Neutron Research (NCNR) to improve the statistical and systematic limitations of an experiment to measure the neutron beta-decay lifetime using magnetically trapped UCN. In the experiment, a monoenergetic 0:89 nm cold neutron is incident on a superfluid 4He target within the minimum field region of an Ioffe type magnetic trap. Some of the neutrons are subsequently downscattered by single phonons in the helium to low energies (≈ 200 neV), and those in the appropriate spin state become trapped. The inverse process, upscattering of UCN, is suppressed by the low phonon density in the < 300 mK helium. When the neutron decays, the energetic electron creates EUV scintillation light, which is down-converted and transported out of the cell to PMTs operated at room temperature. With this method, the decay of the UCN population can be monitored in situ. The apparatus, analysis, data, and systematics will be discussed. After accounting for the systematic effects the measured lifetime disagrees with the current PDG mean neutron beta-decay lifetime by about 9 of our standard deviations, which is a strong indication of unaccounted for systematic effects. Additional 3He contamination will be shown to be the most likely candidate for the additional systematic shift, which motivated the commissioning and initial operation of a heat flush purifier for purifying additional 4He. This work ends with a description of the 4He purifier and its performance.

  15. On Replacing "Quantum Thinking" with Counterfactual Reasoning

    NASA Astrophysics Data System (ADS)

    Narens, Louis

    The probability theory used in quantum mechanics is currently being employed by psychologists to model the impact of context on decision. Its event space consists of closed subspaces of a Hilbert space, and its probability function sometimes violate the law of the finite additivity of probabilities. Results from the quantum mechanics literature indicate that such a "Hilbert space probability theory" cannot be extended in a useful way to standard, finitely additive, probability theory by the addition of new events with specific probabilities. This chapter presents a new kind of probability theory that shares many fundamental algebraic characteristics with Hilbert space probability theory but does extend to standard probability theory by adjoining new events with specific probabilities. The new probability theory arises from considerations about how psychological experiments are related through counterfactual reasoning.

  16. Longitudinal Study Transformed Onboarding Nurse Graduates.

    PubMed

    Slate, Kimberly A; Stavarski, Debra H; Romig, Barbara J; Thacker, Karen S

    The outcomes of a longitudinal research study on a nurse residency program indicated improvement in the onboarding experience for new graduate nurses. Practice changes and implications for nursing professional development practitioners resulting from the study include the number and orientation of preceptors, program length standardization, and improvement of emergency clinical response education. Additional research studies were implemented to further explore issues novice nurses and their proficient registered nurse colleagues experience throughout the organization.

  17. Changes to pediatric clerkships' nighttime structure after introduction of the 2011 ACGME resident duty hour standards.

    PubMed

    Smith, Andrew; Stevenson, Adam

    2014-01-01

    To report changes in pediatric clerkship nighttime clinical structures before and after implementation of the 2011 Accreditation Council for Graduate Medical Education (ACGME) resident duty hour standards. As part of the 2011 Council on Medical Student Education in Pediatrics (COMSEP) member annual survey, we surveyed leaders of pediatric undergraduate medical education on their medical school's current nighttime clinical structure, changes in nighttime structure between 2010 and 2011, and their school's student duty hour standards. Fifty-six percent (n = 83) of Liaison Committee for Medical Education (LCME)-accredited medical schools responded to the survey. Of received responses, 98% of pediatric clerkships have some form of nighttime clinical experience; 49% of clerkships have medical students stay late, 24% of clerkships utilize night shifts, and 16% use a traditional call structure. Forty-five percent of clerkships report changing their nighttime clinical experience after implementation of the 2011 ACGME duty hour standards; 46% of clerkships that changed had previously used traditional call. Seventy-six percent of clerkships report having medical student duty hour standards at their medical school. The majority of pediatric clerkships in our survey include nighttime clinical experiences in their curriculum, although variability exists in the type of structure. Additionally, the new ACGME duty hour standards appear to affect clerkships directors' choice of structure. Copyright © 2014 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  18. Control vocabulary software designed for CMIP6

    NASA Astrophysics Data System (ADS)

    Nadeau, D.; Taylor, K. E.; Williams, D. N.; Ames, S.

    2016-12-01

    The Coupled Model Intercomparison Project Phase 6 (CMIP6) coordinates a number of intercomparison activities and includes many more experiments than its predecessor, CMIP5. In order to organize and facilitate use of the complex collection of expected CMIP6 model output, a standard set of descriptive information has been defined, which must be stored along with the data. This standard information enables automated machine interpretation of the contents of all model output files. The standard metadata is stored in compliance with the Climate and Forecast (CF) standard, which ensures that it can be interpreted and visualized by many standard software packages. Additional attributes (not standardized by CF) are required by CMIP6 to enhance identification of models and experiments, and to provide additional information critical for interpreting the model results. To ensure that CMIP6 data complies with the standards, a python program called "PrePARE" (Pre-Publication Attribute Reviewer for the ESGF) has been developed to check the model output prior to its publication and release for analysis. If, for example, a required attribute is missing or incorrect (e.g., not included in the reference CMIP6 controlled vocabularies), then PrePare will prevent publication. In some circumstances, missing attributes can be created or incorrect attributes can be replaced automatically by PrePARE, and the program will warn users about the changes that have been made. PrePARE provides a final check on model output assuring adherence to a baseline conformity across the output from all CMIP6 models which will facilitate analysis by climate scientists. PrePARE is flexible and can be easily modified for use by similar projects that have a well-defined set of metadata and controlled vocabularies.

  19. Nonlinear resonances in linear segmented Paul trap of short central segment.

    PubMed

    Kłosowski, Łukasz; Piwiński, Mariusz; Pleskacz, Katarzyna; Wójtewicz, Szymon; Lisak, Daniel

    2018-03-23

    Linear segmented Paul trap system has been prepared for ion mass spectroscopy experiments. A non-standard approach to stability of trapped ions is applied to explain some effects observed with ensembles of calcium ions. Trap's stability diagram is extended to 3-dimensional one using additional ∆a besides standard q and a stability parameters. Nonlinear resonances in (q,∆a) diagrams are observed and described with a proposed model. The resonance lines have been identified using simple simulations and comparing the numerical and experimental results. The phenomenon can be applied in electron-impact ionization experiments for mass-identification of obtained ions or purification of their ensembles. This article is protected by copyright. All rights reserved.

  20. Universal donor education and consent: what we know and where we should go.

    PubMed

    Wehrli, Gay; Sazama, Kathleen

    2010-11-01

    Each day thousands of blood donors across the country are given educational materials and sign a consent form, thus fulfilling two blood collection accreditation requirements. Very few donors will experience a documented adverse event, although a disproportionate number of these events occur in the youngest donor cohort. The literature reflects this disproportion and suggests mitigation strategies. Studies describe subjective, undocumented donor reactions and decreased donor return rates after a documented or subjective reaction. Additionally, studies have shown donor consent form variability among blood collection facilities and that donor comprehension of the educational materials and consent is limited. There are few standardized donor education materials or consent documents. Current accreditation standards for educational materials are limited to aspects of transfusion-transmitted diseases and for donor consent process and documentation are vague and nonspecific. Recent experiences with young donors and current research compel our community to engage in creating standardized, expanded donor educational materials and standardized donor consent processes and documents. © 2010 American Association of Blood Banks.

  1. 42 CFR 493.1411 - Standard; Technical consultant qualifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory... degree in a chemical, physical or biological science or medical technology from an accredited institution... biology and additionally has documentation of 2 years of work experience performing tests of moderate...

  2. 42 CFR 493.1411 - Standard; Technical consultant qualifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory... degree in a chemical, physical or biological science or medical technology from an accredited institution... biology and additionally has documentation of 2 years of work experience performing tests of moderate...

  3. 42 CFR 493.1411 - Standard; Technical consultant qualifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory... degree in a chemical, physical or biological science or medical technology from an accredited institution... biology and additionally has documentation of 2 years of work experience performing tests of moderate...

  4. 42 CFR 493.1411 - Standard; Technical consultant qualifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory... degree in a chemical, physical or biological science or medical technology from an accredited institution... biology and additionally has documentation of 2 years of work experience performing tests of moderate...

  5. Positive effect on patient experience of video information given prior to cardiovascular magnetic resonance imaging: A clinical trial.

    PubMed

    Ahlander, Britt-Marie; Engvall, Jan; Maret, Eva; Ericsson, Elisabeth

    2018-03-01

    To evaluate the effect of video information given before cardiovascular magnetic resonance imaging on patient anxiety and to compare patient experiences of cardiovascular magnetic resonance imaging versus myocardial perfusion scintigraphy. To evaluate whether additional information has an impact on motion artefacts. Cardiovascular magnetic resonance imaging and myocardial perfusion scintigraphy are technically advanced methods for the evaluation of heart diseases. Although cardiovascular magnetic resonance imaging is considered to be painless, patients may experience anxiety due to the closed environment. A prospective randomised intervention study, not registered. The sample (n = 148) consisted of 97 patients referred for cardiovascular magnetic resonance imaging, randomised to receive either video information in addition to standard text-information (CMR-video/n = 49) or standard text-information alone (CMR-standard/n = 48). A third group undergoing myocardial perfusion scintigraphy (n = 51) was compared with the cardiovascular magnetic resonance imaging-standard group. Anxiety was evaluated before, immediately after the procedure and 1 week later. Five questionnaires were used: Cardiac Anxiety Questionnaire, State-Trait Anxiety Inventory, Hospital Anxiety and Depression scale, MRI Fear Survey Schedule and the MRI-Anxiety Questionnaire. Motion artefacts were evaluated by three observers, blinded to the information given. Data were collected between April 2015-April 2016. The study followed the CONSORT guidelines. The CMR-video group scored lower (better) than the cardiovascular magnetic resonance imaging-standard group in the factor Relaxation (p = .039) but not in the factor Anxiety. Anxiety levels were lower during scintigraphic examinations compared to the CMR-standard group (p < .001). No difference was found regarding motion artefacts between CMR-video and CMR-standard. Patient ability to relax during cardiovascular magnetic resonance imaging increased by adding video information prior the exam, which is important in relation to perceived quality in nursing. No effect was seen on motion artefacts. Video information prior to examinations can be an easy and time effective method to help patients cooperate in imaging procedures. © 2017 John Wiley & Sons Ltd.

  6. Highlights from High Energy Neutrino Experiments at CERN

    NASA Astrophysics Data System (ADS)

    Schlatter, W.-D.

    2015-07-01

    Experiments with high energy neutrino beams at CERN provided early quantitative tests of the Standard Model. This article describes results from studies of the nucleon quark structure and of the weak current, together with the precise measurement of the weak mixing angle. These results have established a new quality for tests of the electroweak model. In addition, the measurements of the nucleon structure functions in deep inelastic neutrino scattering allowed first quantitative tests of QCD.

  7. Memory for pictures and sounds: independence of auditory and visual codes.

    PubMed

    Thompson, V A; Paivio, A

    1994-09-01

    Three experiments examined the mnemonic independence of auditory and visual nonverbal stimuli in free recall. Stimulus lists consisted of (1) pictures, (2) the corresponding environmental sounds, or (3) picture-sound pairs. In Experiment 1, free recall was tested under three learning conditions: standard intentional, intentional with a rehearsal-inhibiting distracter task, or incidental with the distracter task. In all three groups, recall was best for the picture-sound items. In addition, recall for the picture-sound stimuli appeared to be additive relative to pictures or sounds alone when the distracter task was used. Experiment 2 included two additional groups: In one, two copies of the same picture were shown simultaneously; in the other, two different pictures of the same concept were shown. There was no difference in recall among any of the picture groups; in contrast, recall in the picture-sound condition was greater than recall in either single-modality condition. However, doubling the exposure time in a third experiment resulted in additively higher recall for repeated pictures with different exemplars than ones with identical exemplars. The results are discussed in terms of dual coding theory and alternative conceptions of the memory trace.

  8. Chamber QoE: a multi-instrumental approach to explore affective aspects in relation to quality of experience

    NASA Astrophysics Data System (ADS)

    De Moor, Katrien; Mazza, Filippo; Hupont, Isabelle; Ríos Quintero, Miguel; Mäki, Toni; Varela, Martín.

    2014-02-01

    Evaluating (audio)visual quality and Quality of Experience (QoE) from the user's perspective, has become a key element in optimizing users' experiences and their quality. Traditionally, the focus lies on how multi-level quality features are perceived by a human user. The interest has however gradually expanded towards human cognitive, affective and behavioral processes that may impact on, be an element of, or be influenced by QoE, and which have been underinvestigated so far. In addition, there is a major discrepancy between the new, broadly supported and more holistic conceptualization of QoE proposed by Le Callet et al. (2012) and traditional, standardized QoE assessment. This paper explores ways to tackle this discrepancy by means of a multi-instrumental approach. More concretely, it presents results from a lab study on video quality (N=27), aimed at going beyond the dominant QoE assessment paradigm and at exploring affective aspects in relation to QoE and in relation to perceived overall quality. Four types of data were collected: `traditional' QoE self-report measures were complemented with `alternative', emotional state- and user engagement-related self-report measures to evaluate QoE. In addition, we collected EEG (physiological) data, gazetracking data and facial expressions (behavioral) data. The video samples used in test were longer in duration than is common in standard tests allowing us to study e.g. more realistic experience and deeper user engagement. Our findings support the claim that the traditional QoE measures need to be reconsidered and extended with additional, affective staterelated measures.

  9. The early universe as a probe of new physics

    NASA Astrophysics Data System (ADS)

    Bird, Christopher Shane

    The Standard Model of Particle Physics has been verified to unprecedented precision in the last few decades. However there are still phenomena in nature which cannot be explained, and as such new theories will be required. Since terrestrial experiments are limited in both the energy and precision that can be probed, new methods are required to search for signs of physics beyond the Standard Model. In this dissertation, I demonstrate how these theories can be probed by searching for remnants of their effects in the early Universe. In particular I focus on three possible extensions of the Standard Model: the addition of massive neutral particles as dark matter, the addition of charged massive particles, and the existence of higher dimensions. For each new model, I review the existing experimental bounds and the potential for discovering new physics in the next generation of experiments. For dark matter, I introduce six simple models which I have developed, and which involve a minimum amount of new physics, as well as reviewing one existing model of dark matter. For each model I calculate the latest constraints from astrophysics experiments, nuclear recoil experiments, and collider experiments. I also provide motivations for studying sub-GeV mass dark matter, and propose the possibility of searching for light WIMPs in the decay of B-mesons and other heavy particles. For charged massive relics, I introduce and review the recently proposed model of catalyzed Big Bang nucleosynthesis. In particular I review the production of 6Li by this mechanism, and calculate the abundance of 7Li after destruction of 7Be by charged relics. The result is that for certain natural relics CBBN is capable of removing tensions between the predicted and observed 6Li and 7Li abundances which are present in the standard model of BBN. For extra dimensions, I review the constraints on the ADD model from both astrophysics and collider experiments. I then calculate the constraints on this model from Big Bang nucleosynthesis in the early Universe. I also calculate the bounds on this model from Kaluza-Klein gravitons trapped in the galaxy which decay to electron-positron pairs, using the measured 511 keV gamma-ray flux. For each example of new physics, I find that remnants of the early Universe provide constraints on the models which are complementary to the existing constraints from colliders and other terrestrial experiments.

  10. A survey of useful salt additives in matrix-assisted laser desorption/ionization mass spectrometry and tandem mass spectrometry of lipids: introducing nitrates for improved analysis.

    PubMed

    Griffiths, Rian L; Bunch, Josephine

    2012-07-15

    Matrix-assisted laser desorption/ionization (MALDI) is a powerful technique for the direct analysis of lipids in complex mixtures and thin tissue sections, making it an extremely attractive method for profiling lipids in health and disease. Lipids are readily detected as [M+H](+), [M+Na](+) and [M+K](+) ions in positive ion MALDI mass spectrometry (MS) experiments. This not only decreases sensitivity, but can also lead to overlapping m/z values of the various adducts of different lipids. Additives can be used to promote formation of a particular adduct, improving sensitivity, reducing spectral complexity and enhancing structural characterization in collision-induced dissociation (CID) experiments. Li(+), Na(+), K(+), Cs(+) and NH(4)(+) cations were considered as a range of salt types (acetates, chlorides and nitrates) incorporated into DHB matrix solutions at concentrations between 5 and 80 mM. The study was extended to evaluate the effect of these additives on CID experiments of a lipid standard, after optimization of collision energy parameters. Experiments were performed on a hybrid quadrupole time-of-flight (QqTOF) instrument. The systematic evaluation of new and existing additives in MALDI-MS and MS/MS of lipids demonstrated the importance of additive cation and anion choice and concentration for tailoring spectral results. The recommended choice of additive depends on the desired outcomes of the experiment to be performed (MS or MS/MS). Nitrates are found to be particularly useful additives for lipid analysis. Copyright © 2012 John Wiley & Sons, Ltd.

  11. [Effects of sludge compost used as lawn medium on lawn growth and soil and water environment].

    PubMed

    Jin, Shu-Quan; Zhou, Jin-Bo; Chen, Ruo-Xia; Lin, Bin; Wang, De-Yao

    2013-10-01

    To address effect of the sludge compost-containing medium on the growth of Manila lawn and environment quality, a pot experiment was conducted using six treatments based on contrasting sludge compost addition volume ratios in the soil system (i. e., 0% , 10% , 25% , 50% , 75% and 100%). The results indicated that the growth potential of Manila lawn was increased with increasing sludge compost addition volume ratio. The content of Hg in Manila plant was significantly positively correlated with that in the lawn medium. Although the contents of Cr, Cd and Hg in the lawn medium were synchronously increased with increasing sludge compost addition volume ratio in the soil system, their contents were all lower than the critical levels of third-class standard in the National Soil Environmental Quality Standard. The heavy metal and nitrate concentrations detected in percolating water were significantly positively correlated with those in the lawn medium, respectively. When the sludge compost addition volume ratio was more than 50% in this study, both heavy metal and nitrate concentrations in percolating water would exceed the maximum allowable levels of the National Groundwater Environment Quality Standard.

  12. Modeling the Nab Experiment Electronics in SPICE

    NASA Astrophysics Data System (ADS)

    Blose, Alexander; Crawford, Christopher; Sprow, Aaron; Nab Collaboration

    2017-09-01

    The goal of the Nab experiment is to measure the neutron decay coefficients a, the electron-neutrino correlation, as well as b, the Fierz interference term to precisely test the Standard Model, as well as probe for Beyond the Standard Model physics. In this experiment, protons from the beta decay of the neutron are guided through a magnetic field into a Silicon detector. Event reconstruction will be achieved via time-of-flight measurement for the proton and direct measurement of the coincident electron energy in highly segmented silicon detectors, so the amplification circuitry needs to preserve fast timing, provide good amplitude resolution, and be packaged in a high-density format. We have designed a SPICE simulation to model the full electronics chain for the Nab experiment in order to understand the contributions of each stage and optimize them for performance. Additionally, analytic solutions to each of the components have been determined where available. We will present a comparison of the output from the SPICE model, analytic solution, and empirically determined data.

  13. Extrapolating Accelerated UV Weathering Data: Perspective From PVQAT Task Group 5 (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Annigoni, E.; Ballion, A.

    2015-02-01

    Taskgroup 5 (TG5) is concerned with a accelerated aging standard incorporating factors including ultraviolet radiation, temperature, and moisture. Separate experiments are being conducted in support of a test standard via the regional sub-groups in Asia, Europe, and the United States. The authors will describe the objectives and timeline for the TG5 interlaboratory study being directed out of the USA. Qualitative preliminary data from the experiment is presented. To date, the encapsulation transmittance experiment has: replicated behaviors of fielded materials (including specimen location- and formulation additive-specific discoloration); demonstrated coupling between UV aging and temperature; demonstrated that degradation in EVA results frommore » UV- aging; and obtained good qualitative comparison between Xe and UVA-340 sources for EVA. To date, the encapsulation adhesion experiment (using the compressive shear test to quantify strength of attachment) has demonstrated that attachment strength can decrease drastically (>50%) with age; however, early results suggest significant factor (UV, T, RH) dependence. Much remains to be learned about adhesion.« less

  14. Results of the 1980 NASA/JPL balloon flight solar cell calibration program

    NASA Technical Reports Server (NTRS)

    Seaman, C. H.; Weiss, R. S.

    1981-01-01

    Thirty-eight modules were carried to an altitude of about 36 kilometers. In addition to the cell calibration program, an experiment to evaluate the calibration error versus altitude was performed. The calibrated cells can be used as reference standards in simulator testing of cells and arrays.

  15. The Virginia Geocoin Adventure: An Experiential Geospatial Learning Activity

    ERIC Educational Resources Information Center

    Johnson, Laura; McGee, John; Campbell, James; Hays, Amy

    2013-01-01

    Geospatial technologies have become increasingly prevalent across our society. Educators at all levels have expressed a need for additional resources that can be easily adopted to support geospatial literacy and state standards of learning, while enhancing the overall learning experience. The Virginia Geocoin Adventure supports the needs of 4-H…

  16. Response Modality Variations Affect Determinations of Children's Learning Styles.

    ERIC Educational Resources Information Center

    Janowitz, Jeffrey M.

    The Swassing-Barbe Modality Index (SBMI) uses visual, auditory, and tactile inputs, but only reconstructed output, to measure children's modality strengths. In this experiment, the SBMI's three input modalities were crossed with two output modalities (spoken and drawn) in addition to the reconstructed standard to result in nine treatment…

  17. Development, implementation, and experimentation of parametric routing protocol for sensor networks

    NASA Astrophysics Data System (ADS)

    Nassr, Matthew S.; Jun, Jangeun; Eidenbenz, Stephan J.; Frigo, Janette R.; Hansson, Anders A.; Mielke, Angela M.; Smith, Mark C.

    2006-09-01

    The development of a scalable and reliable routing protocol for sensor networks is traced from a theoretical beginning to positive simulation results to the end of verification experiments in large and heavily loaded networks. Design decisions and explanations as well as implementation hurdles are presented to give a complete picture of protocol development. Additional software and hardware is required to accurately test the performance of our protocol in field experiments. In addition, the developed protocol is tested in TinyOS on Mica2 motes against well-established routing protocols frequently used in sensor networks. Our protocol proves to outperform the standard (MINTRoute) and the trivial (Gossip) in a variety of different scenarios.

  18. Experience with The Use of Warm Mix Asphalt Additives in Bitumen Binders

    NASA Astrophysics Data System (ADS)

    Cápayová, Silvia; Unčík, Stanislav; Cihlářová, Denisa

    2018-03-01

    In most European countries, Hot Mix Asphalt (HMA) technology is still being used as the standard for the production and processing of bituminous mixtures. However, from the perspective of environmental acceptability, global warming and greenhouse gas production, Slovakia is making an effort to put into practice modern technology, which is characterized by lower energy consumption and reducing negative impacts on the environment. Warm mix asphalt technologies (WMA), which have been verified at the Department of Transportation Engineering laboratory, Faculty of Civil Engineering, Slovak University of Technology (FCE, SUT) can provide the required mixture properties and can be used not only for the construction of new roads, but also for their renovation and reconstruction. The paper was created in cooperation with the Technical University of Ostrava, Czech Republic, which also deals with the addition of additives to asphalt mixtures and binders. It describes a comparison of the impact of some organic and chemical additives on the properties of commonly used bitumen binders in accordance with valid standards and technical regulations.

  19. The impact of response measurement error on the analysis of designed experiments

    DOE PAGES

    Anderson-Cook, Christine Michaela; Hamada, Michael Scott; Burr, Thomas Lee

    2016-11-01

    This study considers the analysis of designed experiments when there is measurement error in the true response or so-called response measurement error. We consider both additive and multiplicative response measurement errors. Through a simulation study, we investigate the impact of ignoring the response measurement error in the analysis, that is, by using a standard analysis based on t-tests. In addition, we examine the role of repeat measurements in improving the quality of estimation and prediction in the presence of response measurement error. We also study a Bayesian approach that accounts for the response measurement error directly through the specification ofmore » the model, and allows including additional information about variability in the analysis. We consider the impact on power, prediction, and optimization. Copyright © 2015 John Wiley & Sons, Ltd.« less

  20. The impact of response measurement error on the analysis of designed experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson-Cook, Christine Michaela; Hamada, Michael Scott; Burr, Thomas Lee

    This study considers the analysis of designed experiments when there is measurement error in the true response or so-called response measurement error. We consider both additive and multiplicative response measurement errors. Through a simulation study, we investigate the impact of ignoring the response measurement error in the analysis, that is, by using a standard analysis based on t-tests. In addition, we examine the role of repeat measurements in improving the quality of estimation and prediction in the presence of response measurement error. We also study a Bayesian approach that accounts for the response measurement error directly through the specification ofmore » the model, and allows including additional information about variability in the analysis. We consider the impact on power, prediction, and optimization. Copyright © 2015 John Wiley & Sons, Ltd.« less

  1. EuroFlow standardization of flow cytometer instrument settings and immunophenotyping protocols

    PubMed Central

    Kalina, T; Flores-Montero, J; van der Velden, V H J; Martin-Ayuso, M; Böttcher, S; Ritgen, M; Almeida, J; Lhermitte, L; Asnafi, V; Mendonça, A; de Tute, R; Cullen, M; Sedek, L; Vidriales, M B; Pérez, J J; te Marvelde, J G; Mejstrikova, E; Hrusak, O; Szczepański, T; van Dongen, J J M; Orfao, A

    2012-01-01

    The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database. PMID:22948490

  2. Unobtrusive measurement of indoor energy expenditure using an infrared sensor-based activity monitoring system.

    PubMed

    Hwang, Bosun; Han, Jonghee; Choi, Jong Min; Park, Kwang Suk

    2008-11-01

    The purpose of this study was to develop an unobtrusive energy expenditure (EE) measurement system using an infrared (IR) sensor-based activity monitoring system to measure indoor activities and to estimate individual quantitative EE. IR-sensor activation counts were measured with a Bluetooth-based monitoring system and the standard EE was calculated using an established regression equation. Ten male subjects participated in the experiment and three different EE measurement systems (gas analyzer, accelerometer, IR sensor) were used simultaneously in order to determine the regression equation and evaluate the performance. As a standard measurement, oxygen consumption was simultaneously measured by a portable metabolic system (Metamax 3X, Cortex, Germany). A single room experiment was performed to develop a regression model of the standard EE measurement from the proposed IR sensor-based measurement system. In addition, correlation and regression analyses were done to compare the performance of the IR system with that of the Actigraph system. We determined that our proposed IR-based EE measurement system shows a similar correlation to the Actigraph system with the standard measurement system.

  3. Statistical inference from multiple iTRAQ experiments without using common reference standards.

    PubMed

    Herbrich, Shelley M; Cole, Robert N; West, Keith P; Schulze, Kerry; Yager, James D; Groopman, John D; Christian, Parul; Wu, Lee; O'Meally, Robert N; May, Damon H; McIntosh, Martin W; Ruczinski, Ingo

    2013-02-01

    Isobaric tags for relative and absolute quantitation (iTRAQ) is a prominent mass spectrometry technology for protein identification and quantification that is capable of analyzing multiple samples in a single experiment. Frequently, iTRAQ experiments are carried out using an aliquot from a pool of all samples, or "masterpool", in one of the channels as a reference sample standard to estimate protein relative abundances in the biological samples and to combine abundance estimates from multiple experiments. In this manuscript, we show that using a masterpool is counterproductive. We obtain more precise estimates of protein relative abundance by using the available biological data instead of the masterpool and do not need to occupy a channel that could otherwise be used for another biological sample. In addition, we introduce a simple statistical method to associate proteomic data from multiple iTRAQ experiments with a numeric response and show that this approach is more powerful than the conventionally employed masterpool-based approach. We illustrate our methods using data from four replicate iTRAQ experiments on aliquots of the same pool of plasma samples and from a 406-sample project designed to identify plasma proteins that covary with nutrient concentrations in chronically undernourished children from South Asia.

  4. Magnetoencephalographic responses to illusory figures: early evoked gamma is affected by processing of stimulus features.

    PubMed

    Herrmann, C S; Mecklinger, A

    2000-12-01

    We examined evoked and induced responses in event-related fields and gamma activity in the magnetoencephalogram (MEG) during a visual classification task. The objective was to investigate the effects of target classification and the different levels of discrimination between certain stimulus features. We performed two experiments, which differed only in the subjects' task while the stimuli were identical. In Experiment 1, subjects responded by a button-press to rare Kanizsa squares (targets) among Kanizsa triangles and non-Kanizsa figures (standards). This task requires the processing of both stimulus features (colinearity and number of inducer disks). In Experiment 2, the four stimuli of Experiment 1 were used as standards and the occurrence of an additional stimulus without any feature overlap with the Kanizsa stimuli (a rare and highly salient red fixation cross) had to be detected. Discrimination of colinearity and number of inducer disks was not necessarily required for task performance. We applied a wavelet-based time-frequency analysis to the data and calculated topographical maps of the 40 Hz activity. The early evoked gamma activity (100-200 ms) in Experiment 1 was higher for targets as compared to standards. In Experiment 2, no significant differences were found in the gamma responses to the Kanizsa figures and non-Kanizsa figures. This pattern of results suggests that early evoked gamma activity in response to visual stimuli is affected by the targetness of a stimulus and the need to discriminate between the features of a stimulus.

  5. The virtual lover: variable and easily guided 3D fish animations as an innovative tool in mate-choice experiments with sailfin mollies-I. Design and implementation

    PubMed Central

    Smielik, Ievgen; Hütwohl, Jan-Marco; Gierszewski, Stefanie; Witte, Klaudia; Kuhnert, Klaus-Dieter

    2017-01-01

    Abstract Animal behavior researchers often face problems regarding standardization and reproducibility of their experiments. This has led to the partial substitution of live animals with artificial virtual stimuli. In addition to standardization and reproducibility, virtual stimuli open new options for researchers since they are easily changeable in morphology and appearance, and their behavior can be defined. In this article, a novel toolchain to conduct behavior experiments with fish is presented by a case study in sailfin mollies Poecilia latipinna. As the toolchain holds many different and novel features, it offers new possibilities for studies in behavioral animal research and promotes the standardization of experiments. The presented method includes options to design, animate, and present virtual stimuli to live fish. The designing tool offers an easy and user-friendly way to define size, coloration, and morphology of stimuli and moreover it is able to configure virtual stimuli randomly without any user influence. Furthermore, the toolchain brings a novel method to animate stimuli in a semiautomatic way with the help of a game controller. These created swimming paths can be applied to different stimuli in real time. A presentation tool combines models and swimming paths regarding formerly defined playlists, and presents the stimuli onto 2 screens. Experiments with live sailfin mollies validated the usage of the created virtual 3D fish models in mate-choice experiments. PMID:29491963

  6. The virtual lover: variable and easily guided 3D fish animations as an innovative tool in mate-choice experiments with sailfin mollies-I. Design and implementation.

    PubMed

    Müller, Klaus; Smielik, Ievgen; Hütwohl, Jan-Marco; Gierszewski, Stefanie; Witte, Klaudia; Kuhnert, Klaus-Dieter

    2017-02-01

    Animal behavior researchers often face problems regarding standardization and reproducibility of their experiments. This has led to the partial substitution of live animals with artificial virtual stimuli. In addition to standardization and reproducibility, virtual stimuli open new options for researchers since they are easily changeable in morphology and appearance, and their behavior can be defined. In this article, a novel toolchain to conduct behavior experiments with fish is presented by a case study in sailfin mollies Poecilia latipinna . As the toolchain holds many different and novel features, it offers new possibilities for studies in behavioral animal research and promotes the standardization of experiments. The presented method includes options to design, animate, and present virtual stimuli to live fish. The designing tool offers an easy and user-friendly way to define size, coloration, and morphology of stimuli and moreover it is able to configure virtual stimuli randomly without any user influence. Furthermore, the toolchain brings a novel method to animate stimuli in a semiautomatic way with the help of a game controller. These created swimming paths can be applied to different stimuli in real time. A presentation tool combines models and swimming paths regarding formerly defined playlists, and presents the stimuli onto 2 screens. Experiments with live sailfin mollies validated the usage of the created virtual 3D fish models in mate-choice experiments.

  7. A visual demo of the Doppler effect

    NASA Astrophysics Data System (ADS)

    Papacosta, Pangratios

    2010-09-01

    Most physics teachers are familiar with the standard classroom demonstration of the Doppler effect. We invite students to explain the periodic variation of the pitch produced when we swirl a sounding buzzer over our heads. Students are quick to connect this phenomenon to everyday life experiences such as listening to the sound of the siren of a fast-approaching police car or the bell of an approaching train. In addition to these aural experiences, our understanding of the Doppler effect can be strengthened with a useful visual metaphor.

  8. Operations Praetorian, Phalanx, Fusileer, and Grenadier, Events HURON LANDING/DIAMOND ACE, MINI JADE, TOMME/MIDNIGHT ZEPHYR, MIDAS MYTH/MILAGRO and MISTY RAIN

    DTIC Science & Technology

    1993-07-01

    General requirements and standards governing safety were based on the FCTC "Safety and Health Compliance Guide for Underground and Nuclear Effects Tests...Defense (DOD)-sponsored underground nuclear tests were conducted from 23 September 1982 through 6 April 1985 to study weapons effects . All six were...weapons- related or effects purposes, and 33 were safety experiments. An additional 24 nuclear experiments were conducted from December 1954 to February

  9. The Standards Agenda: Reflections of a Special Educational Needs Co-ordinator

    ERIC Educational Resources Information Center

    Glazzard, Jonathan

    2014-01-01

    This study is a life history account of Bev, a special educational needs co-ordinator who works in a primary school in England. The research examines how, within Bev's experiences, the discourses of integration and inclusion have affected learners with special educational needs. Additionally, the study examines the impact of the…

  10. Recommended Protocol for Round Robin Studies in Additive Manufacturing

    PubMed Central

    Moylan, Shawn; Brown, Christopher U.; Slotwinski, John

    2016-01-01

    One way to improve confidence and encourage proliferation of additive manufacturing (AM) technologies and parts is by generating more high quality data describing the performance of AM processes and parts. Many in the AM community see round robin studies as a way to generate large data sets while distributing the cost among the participants, thereby reducing the cost to individual users. The National Institute of Standards and Technology (NIST) has conducted and participated in several of these AM round robin studies. While the results of these studies are interesting and informative, many of the lessons learned in conducting these studies concern the logistics and methods of the study and unique issues presented by AM. Existing standards for conducting interlaboratory studies of measurement methods, along with NIST’s experience, form the basis for recommended protocols for conducting AM round robin studies. The role of round robin studies in AM qualification, some of the limitations of round robin studies, and the potential benefit of less formal collaborative experiments where multiple factors, AM machine being only one, are varied simultaneously are also discussed. PMID:27274602

  11. Recommended Protocol for Round Robin Studies in Additive Manufacturing.

    PubMed

    Moylan, Shawn; Brown, Christopher U; Slotwinski, John

    2016-03-01

    One way to improve confidence and encourage proliferation of additive manufacturing (AM) technologies and parts is by generating more high quality data describing the performance of AM processes and parts. Many in the AM community see round robin studies as a way to generate large data sets while distributing the cost among the participants, thereby reducing the cost to individual users. The National Institute of Standards and Technology (NIST) has conducted and participated in several of these AM round robin studies. While the results of these studies are interesting and informative, many of the lessons learned in conducting these studies concern the logistics and methods of the study and unique issues presented by AM. Existing standards for conducting interlaboratory studies of measurement methods, along with NIST's experience, form the basis for recommended protocols for conducting AM round robin studies. The role of round robin studies in AM qualification, some of the limitations of round robin studies, and the potential benefit of less formal collaborative experiments where multiple factors, AM machine being only one, are varied simultaneously are also discussed.

  12. Manufacturer evaluations of endograft modifications.

    PubMed

    Waninger, Matthew S; Whirley, Robert G; Smith, Louis J; Wolf, Ben S

    2013-03-01

    The motivation to modify the design of a vascular device can arise from a number of sources. Clinical experience with the unmodified device could suggest new design modifications to improve device performance or clinical outcomes. Similarly, clinical success with a device often suggests modifications that could broaden the applicability of the device to enable treatment of different or more advanced disease states. As a specific example, both of these scenarios have arisen during the last decade in the evolution of endovascular grafts for the treatment of abdominal aortic aneurysms, with modifications enabling the treatment of patients with shorter infrarenal necks, more angulated anatomy, and smaller access vessels. These modifications have been made by manufacturers and additionally by physicians who create branched and fenestrated devices. The experience to date with the use of fenestrated devices and the development of chimney, snorkel, and periscope techniques suggests that modifications to off-the-shelf devices may provide some clinical benefit. This experience provides additional motivation for manufacturers to develop devices to address the clinical needs not met with their current product lines. For manufacturers, the device development process includes an assessment of the new device design to determine the appropriate evaluation strategy to support the safety and effectiveness of the modified device. This report provides a high-level overview of the process generally followed by device manufacturers to evaluate a proposed device modification before market release, in accordance with local country regulations and recognized international standards such as the International Organization of Standardization (ISO) standards for endovascular grafts (ISO 25539 Part 1). Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  13. Cosmology in Mirror Twin Higgs and neutrino masses

    NASA Astrophysics Data System (ADS)

    Chacko, Zackaria; Craig, Nathaniel; Fox, Patrick J.; Harnik, Roni

    2017-07-01

    We explore a simple solution to the cosmological challenges of the original Mirror Twin Higgs (MTH) model that leads to interesting implications for experiment. We consider theories in which both the standard model and mirror neutrinos acquire masses through the familiar seesaw mechanism, but with a low right-handed neutrino mass scale of order a few GeV. In these νMTH models, the right-handed neutrinos leave the thermal bath while still relativistic. As the universe expands, these particles eventually become nonrelativistic, and come to dominate the energy density of the universe before decaying. Decays to standard model states are preferred, with the result that the visible sector is left at a higher temperature than the twin sector. Consequently the contribution of the twin sector to the radiation density in the early universe is suppressed, allowing the current bounds on this scenario to be satisfied. However, the energy density in twin radiation remains large enough to be discovered in future cosmic microwave background experiments. In addition, the twin neutrinos are significantly heavier than their standard model counterparts, resulting in a sizable contribution to the overall mass density in neutrinos that can be detected in upcoming experiments designed to probe the large scale structure of the universe.

  14. Dark matter and neutrino masses from a scale-invariant multi-Higgs portal

    NASA Astrophysics Data System (ADS)

    Karam, Alexandros; Tamvakis, Kyriakos

    2015-10-01

    We consider a classically scale invariant version of the Standard Model, extended by an extra dark S U (2 )X gauge group. Apart from the dark gauge bosons and a dark scalar doublet which is coupled to the Standard Model Higgs through a portal coupling, we incorporate right-handed neutrinos and an additional real singlet scalar field. After symmetry breaking à la Coleman-Weinberg, we examine the multi-Higgs sector and impose theoretical and experimental constraints. In addition, by computing the dark matter relic abundance and the spin-independent scattering cross section off a nucleon we determine the viable dark matter mass range in accordance with present limits. The model can be tested in the near future by collider experiments and direct detection searches such as XENON 1T.

  15. An analysis of lethal and sublethal interactions among type I and type II pyrethroid pesticide mixtures using standard Hyalella azteca water column toxicity tests.

    PubMed

    Hoffmann, Krista Callinan; Deanovic, Linda; Werner, Inge; Stillway, Marie; Fong, Stephanie; Teh, Swee

    2016-10-01

    A novel 2-tiered analytical approach was used to characterize and quantify interactions between type I and type II pyrethroids in Hyalella azteca using standardized water column toxicity tests. Bifenthrin, permethrin, cyfluthrin, and lambda-cyhalothrin were tested in all possible binary combinations across 6 experiments. All mixtures were analyzed for 4-d lethality, and 2 of the 6 mixtures (permethrin-bifenthrin and permethrin-cyfluthrin) were tested for subchronic 10-d lethality and sublethal effects on swimming motility and growth. Mixtures were initially analyzed for interactions using regression analyses, and subsequently compared with the additive models of concentration addition and independent action to further characterize mixture responses. Negative interactions (antagonistic) were significant in 2 of the 6 mixtures tested, including cyfluthrin-bifenthrin and cyfluthrin-permethrin, but only on the acute 4-d lethality endpoint. In both cases mixture responses fell between the additive models of concentration addition and independent action. All other mixtures were additive across 4-d lethality, and bifenthrin-permethrin and cyfluthrin-permethrin were also additive in terms of subchronic 10-d lethality and sublethal responses. Environ Toxicol Chem 2016;35:2542-2549. © 2016 SETAC. © 2016 SETAC.

  16. Enrichment of the Glycyrrhizic Acid from Licorice Roots (Glycyrrhiza glabra L.) by Isoelectric Focused Adsorptive Bubble Chromatography.

    PubMed

    Karaoğul, Eyyüp; Parlar, Perihan; Parlar, Harun; Alma, M Hakkı

    2016-01-01

    The main aim of this study was to enrich glycyrrhizic acid ammonium salt known as one of the main compounds of licorice roots (Glycyrrhiza glabra L.) by isoelectric focused adsorptive bubble separation technique with different foaming agents. In the experiments, four bubble separation parameters were used with β-lactoglobulin, albumin bovine, and starch (soluble) preferred as foaming agents and without additives. The enrichment of glycyrrhizic acid ammonium salt into the foam was influenced by different additive substances. The results showed that highest enrichment values were obtained from β-lactoglobulin as much as 368.3 times. The lowest enrichment values (5.9 times) were determined for the application without additive. After enrichment, each experiment of glycyrrhizic acid ammonium salt confirmed that these substances could be quantitatively enriched into the collection vessel with isoelectric focused adsorptive bubble separation technique. The transfer of glycyrrhizic acid ammonium salt into the foam from standard solution in the presence of additive was more efficient than aqueous licorice extract.

  17. Enrichment of the Glycyrrhizic Acid from Licorice Roots (Glycyrrhiza glabra L.) by Isoelectric Focused Adsorptive Bubble Chromatography

    PubMed Central

    Karaoğul, Eyyüp; Parlar, Perihan; Parlar, Harun; Alma, M. Hakkı

    2016-01-01

    The main aim of this study was to enrich glycyrrhizic acid ammonium salt known as one of the main compounds of licorice roots (Glycyrrhiza glabra L.) by isoelectric focused adsorptive bubble separation technique with different foaming agents. In the experiments, four bubble separation parameters were used with β-lactoglobulin, albumin bovine, and starch (soluble) preferred as foaming agents and without additives. The enrichment of glycyrrhizic acid ammonium salt into the foam was influenced by different additive substances. The results showed that highest enrichment values were obtained from β-lactoglobulin as much as 368.3 times. The lowest enrichment values (5.9 times) were determined for the application without additive. After enrichment, each experiment of glycyrrhizic acid ammonium salt confirmed that these substances could be quantitatively enriched into the collection vessel with isoelectric focused adsorptive bubble separation technique. The transfer of glycyrrhizic acid ammonium salt into the foam from standard solution in the presence of additive was more efficient than aqueous licorice extract. PMID:26949562

  18. Experimental investigation of the thriving mystery of sterile neutrinos

    DOE PAGES

    Fava, A.

    2016-04-07

    Here, several “anomalies” have been reported from a variety of experiments studying neutrino oscillations over short baselines (less than 1 km) since 1998. Even though not fully compatible with each other, these results could possibly hint at the existence of at least one additional “sterile” neutrino state beyond the Standard Model picture of Particle Physics.

  19. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    ERIC Educational Resources Information Center

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  20. STAR -Space Time Asymmetry Research

    NASA Astrophysics Data System (ADS)

    van Zoest, Tim; Braxmaier, Claus; Schuldt, Thilo; Allab, Mohammed; Theil, Stephan; Pelivan, Ivanka; Herrmann, Sven; Lümmerzahl, Claus; Peters, Achim; Mühle, Katharina; Wicht, Andreas; Nagel, Moritz; Kovalchuk, Evgeny; Düringshoff, Klaus; Dittus, Hansjürg

    STAR is a proposed satellite mission that aims for significantly improved tests of fundamental space-time symmetry and the foundations of special and general relativity. In total STAR comprises a series of five subsequent missions. The STAR1 mission will measure the constancy of the speed of light to one part in 1019 and derive the Kennedy Thorndike (KT) coefficient of the Mansouri-Sexl test theory to 7x10-10 . The KT experiment will be performed by compar-ison of an iodine standard with a highly stable cavity made from ultra low expansion (ULE) ceramics. With an orbital velocity of 7 km/s the sensitivity to a boost dependent violation of Lorentz invariance as modeled by the KT term in the Mansouri Sexl test theory or a Lorentz violating extension of the standard model (SME) will be significantly enhanced as compared to Earth based experiments. The low noise space environment will additionally enhance the measurement precision such that an overall improvement by a factor of 400 over current Earth based experiments is expected.

  1. Experimental investigation on phase change materials as heating element for non-electric neonatal incubator

    NASA Astrophysics Data System (ADS)

    Matahari, Rho Natta; Putra, Nandy; Ariantara, Bambang; Amin, Muhammad; Prawiro, Erwin

    2017-02-01

    High number of preterm births is one of the issues in improving health standard. The effort to help premature babies is hampered by high cost of NICU care in hospital. In addition, uneven distribution of electricity to remote area made it hard to operate the incubator. Utilization of phase change material beeswax to non-electricity incubator as heating element becomes alternative option to save premature babies. The objective of this experiment is to investigate the most efficient mass of beeswax according to Indonesian National Standard to earn over time and ideal temperature of incubator. Experiment was performed using prototype incubator, which utilizes natural convection phenomenon in the heating process of incubator. Utilization of fin is to accelerate heat distribution in the incubator. Result of experiment showed that the most efficient mass of PCM is 3 kg, which has 2.45 hours of running time for maintaining temperature of incubator in range of 32-36 °C.

  2. Why standard brain-computer interface (BCI) training protocols should be changed: an experimental study.

    PubMed

    Jeunet, Camille; Jahanpour, Emilie; Lotte, Fabien

    2016-06-01

    While promising, electroencephaloraphy based brain-computer interfaces (BCIs) are barely used due to their lack of reliability: 15% to 30% of users are unable to control a BCI. Standard training protocols may be partly responsible as they do not satisfy recommendations from psychology. Our main objective was to determine in practice to what extent standard training protocols impact users' motor imagery based BCI (MI-BCI) control performance. We performed two experiments. The first consisted in evaluating the efficiency of a standard BCI training protocol for the acquisition of non-BCI related skills in a BCI-free context, which enabled us to rule out the possible impact of BCIs on the training outcome. Thus, participants (N = 54) were asked to perform simple motor tasks. The second experiment was aimed at measuring the correlations between motor tasks and MI-BCI performance. The ten best and ten worst performers of the first study were recruited for an MI-BCI experiment during which they had to learn to perform two MI tasks. We also assessed users' spatial ability and pre-training μ rhythm amplitude, as both have been related to MI-BCI performance in the literature. Around 17% of the participants were unable to learn to perform the motor tasks, which is close to the BCI illiteracy rate. This suggests that standard training protocols are suboptimal for skill teaching. No correlation was found between motor tasks and MI-BCI performance. However, spatial ability played an important role in MI-BCI performance. In addition, once the spatial ability covariable had been controlled for, using an ANCOVA, it appeared that participants who faced difficulty during the first experiment improved during the second while the others did not. These studies suggest that (1) standard MI-BCI training protocols are suboptimal for skill teaching, (2) spatial ability is confirmed as impacting on MI-BCI performance, and (3) when faced with difficult pre-training, subjects seemed to explore more strategies and therefore learn better.

  3. Reproducibility in Computational Neuroscience Models and Simulations

    PubMed Central

    McDougal, Robert A.; Bulanova, Anna S.; Lytton, William W.

    2016-01-01

    Objective Like all scientific research, computational neuroscience research must be reproducible. Big data science, including simulation research, cannot depend exclusively on journal articles as the method to provide the sharing and transparency required for reproducibility. Methods Ensuring model reproducibility requires the use of multiple standard software practices and tools, including version control, strong commenting and documentation, and code modularity. Results Building on these standard practices, model sharing sites and tools have been developed that fit into several categories: 1. standardized neural simulators, 2. shared computational resources, 3. declarative model descriptors, ontologies and standardized annotations; 4. model sharing repositories and sharing standards. Conclusion A number of complementary innovations have been proposed to enhance sharing, transparency and reproducibility. The individual user can be encouraged to make use of version control, commenting, documentation and modularity in development of models. The community can help by requiring model sharing as a condition of publication and funding. Significance Model management will become increasingly important as multiscale models become larger, more detailed and correspondingly more difficult to manage by any single investigator or single laboratory. Additional big data management complexity will come as the models become more useful in interpreting experiments, thus increasing the need to ensure clear alignment between modeling data, both parameters and results, and experiment. PMID:27046845

  4. The use of additive ceramic hollow spheres on cement slurry to prevent lost circulation in formation `X' having low pressure fracture

    NASA Astrophysics Data System (ADS)

    Rita, Novia; Mursyidah, Syahindra, Michael

    2018-03-01

    When drilling, if the hydrostatic pressure is higher than formation pressure (fracture pressure) it will cause lost circulation during cementing process. To solve this problem, hydrostatic pressure of slurry can be decreased by lowering the slurry density by using some additives. Ceramic Hollow Spheres (CHS) is lightweight additive. This additive comes with low specific gravity so it can lowered the slurry density. When the low-density slurry used in cementing process, it can prevent low circulation and fractured formation caused by cement itself. Class G cement is used in this experiment with the standard density of this slurry is 15.8 ppg. With the addition of CHS, slurry density lowered to 12.5 ppg. CHS not only used to lower the slurry density, it also used to make the same properties with the standard slurry even the density has been lowered. Both thickening time and compressive strength have not change if the CHS added to the slurry. With addition of CHS, thickening time at 70 Bc reached in 03 hours 12 minutes. For the compressive strength, 2000 psi reached in 07 hours 07 minutes. Addition of CHS can save more time in cementing process of X formation.

  5. Heat budget observations for the FIRE/SRB Wisconsin experiment region from October 9 through November 2, 1986

    NASA Technical Reports Server (NTRS)

    Whitlock, Charles H.; Lecroy, Stuart R.

    1987-01-01

    A map and concise tables are presented which show locations, pixel size, and heat budget products from the NOAA-9 satellite for the FIRE/SRB Wisconsin experiment region during the period 9 October through 2 November 1986. In addition to the operational standard products, a narrowband albedo parameter is calculated and presented based on values from AVHRR band 1. This parameter is useful in identifying and/or quantifying clouds on a global basis using a polar-stereographic grid system.

  6. Effect of an Immersive Preoperative Virtual Reality Experience on Patient Reported Outcomes: A Randomized Controlled Trial.

    PubMed

    Bekelis, Kimon; Calnan, Daniel; Simmons, Nathan; MacKenzie, Todd A; Kakoulides, George

    2017-06-01

    To investigate the effect of exposure to a virtual reality (VR) environment preoperatively on patient-reported outcomes for surgical operations. There is a scarcity of well-developed quality improvement initiatives targeting patient satisfaction. We performed a randomized controlled trial of patients undergoing cranial and spinal operations in a tertiary referral center. Patients underwent a 1:1 randomization to an immersive preoperative VR experience or standard preoperative experience stratified on type of operation. The primary outcome measures were the Evaluation du Vecu de l'Anesthesie Generale (EVAN-G) score and the Amsterdam Preoperative Anxiety and Information (APAIS) score, as markers of the patient's experience during the surgical encounter. During the study period, a total of 127 patients (mean age 55.3 years, 41.9% females) underwent randomization. The average EVAN-G score was 84.3 (standard deviation, SD, 6.4) after VR, and 64.3 (SD, 11.7) after standard preoperative experience (difference, 20.0; 95% confidence interval, CI, 16.6-23.3). Exposure to an immersive VR experience also led to higher APAIS score (difference, 29.9; 95% CI, 24.5-35.2). In addition, VR led to lower preoperative VAS stress score (difference, -41.7; 95% CI, -33.1 to -50.2), and higher preoperative VAS preparedness (difference, 32.4; 95% CI, 24.9-39.8), and VAS satisfaction (difference, 33.2; 95% CI, 25.4-41.0) scores. No association was identified with VAS stress score (difference, -1.6; 95% CI, -13.4 to 10.2). In a randomized controlled trial, we demonstrated that patients exposed to preoperative VR had increased satisfaction during the surgical encounter. Harnessing the power of this technology, hospitals can create an immersive environment that minimizes stress, and enhances the perioperative experience.

  7. Long-Wavelength X-Ray Diffraction and Its Applications in Macromolecular Crystallography.

    PubMed

    Weiss, Manfred S

    2017-01-01

    For many years, diffraction experiments in macromolecular crystallography at X-ray wavelengths longer than that of Cu-K α (1.54 Å) have been largely underappreciated. Effects caused by increased X-ray absorption result in the fact that these experiments are more difficult than the standard diffraction experiments at short wavelengths. However, due to the also increased anomalous scattering of many biologically relevant atoms, important additional structural information can be obtained. This information, in turn, can be used for phase determination, for substructure identification, in molecular replacement approaches, as well as in structure refinement. This chapter reviews the possibilities and the difficulties associated with such experiments, and it provides a short description of two macromolecular crystallography synchrotron beam lines dedicated to long-wavelength X-ray diffraction experiments.

  8. Journal article reporting standards for quantitative research in psychology: The APA Publications and Communications Board task force report.

    PubMed

    Appelbaum, Mark; Cooper, Harris; Kline, Rex B; Mayo-Wilson, Evan; Nezu, Arthur M; Rao, Stephen M

    2018-01-01

    Following a review of extant reporting standards for scientific publication, and reviewing 10 years of experience since publication of the first set of reporting standards by the American Psychological Association (APA; APA Publications and Communications Board Working Group on Journal Article Reporting Standards, 2008), the APA Working Group on Quantitative Research Reporting Standards recommended some modifications to the original standards. Examples of modifications include division of hypotheses, analyses, and conclusions into 3 groupings (primary, secondary, and exploratory) and some changes to the section on meta-analysis. Several new modules are included that report standards for observational studies, clinical trials, longitudinal studies, replication studies, and N-of-1 studies. In addition, standards for analytic methods with unique characteristics and output (structural equation modeling and Bayesian analysis) are included. These proposals were accepted by the Publications and Communications Board of APA and supersede the standards included in the 6th edition of the Publication Manual of the American Psychological Association (APA, 2010). (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  9. Changes in room acoustics elicit a Mismatch Negativity in the absence of overall interaural intensity differences.

    PubMed

    Frey, Johannes Daniel; Wendt, Mike; Löw, Andreas; Möller, Stephan; Zölzer, Udo; Jacobsen, Thomas

    2017-02-15

    Changes in room acoustics provide important clues about the environment of sound source-perceiver systems, for example, by indicating changes in the reflecting characteristics of surrounding objects. To study the detection of auditory irregularities brought about by a change in room acoustics, a passive oddball protocol with participants watching a movie was applied in this study. Acoustic stimuli were presented via headphones. Standards and deviants were created by modelling rooms of different sizes, keeping the values of the basic acoustic dimensions (e.g., frequency, duration, sound pressure, and sound source location) as constant as possible. In the first experiment, each standard and deviant stimulus consisted of sequences of three short sounds derived from sinusoidal tones, resulting in three onsets during each stimulus. Deviant stimuli elicited a Mismatch Negativity (MMN) as well as two additional negative deflections corresponding to the three onset peaks. In the second experiment, only one sound was used; the stimuli were otherwise identical to the ones used in the first experiment. Again, an MMN was observed, followed by an additional negative deflection. These results provide further support for the hypothesis of automatic detection of unattended changes in room acoustics, extending previous work by demonstrating the elicitation of an MMN by changes in room acoustics. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Virtual reality technology prevents accidents in extreme situations

    NASA Astrophysics Data System (ADS)

    Badihi, Y.; Reiff, M. N.; Beychok, S.

    2012-03-01

    This research is aimed at examining the added value of using Virtual Reality (VR) in a driving simulator to prevent road accidents, specifically by improving drivers' skills when confronted with extreme situations. In an experiment, subjects completed a driving scenario using two platforms: A 3-D Virtual Reality display system using an HMD (Head-Mounted Display), and a standard computerized display system based on a standard computer monitor. The results show that the average rate of errors (deviating from the driving path) in a VR environment is significantly lower than in the standard one. In addition, there was no compensation between speed and accuracy in completing the driving mission. On the contrary: The average speed was even slightly faster in the VR simulation than in the standard environment. Thus, generally, despite the lower rate of deviation in VR setting, it is not achieved by driving slower. When the subjects were asked about their personal experiences from the training session, most of the subjects responded that among other things, the VR session caused them to feel a higher sense of commitment to the task and their performance. Some of them even stated that the VR session gave them a real sensation of driving.

  11. The Bnl Muon Anomalous Magnetic Moment Measurement

    NASA Astrophysics Data System (ADS)

    Hertzog, David W.

    2003-09-01

    The E821 experiment at Brookhaven National Laboratory is designed to measure the muon magnetic anomaly, aμ, to an ultimate precision of 0.4 parts per million (ppm). Because theory can predict aμ to 0.6 ppm, and ongoing efforts aim to reduce this uncertainty, the comparison represents an important and sensitive test of new physics. At the time of this Workshop, the reported experimental result from the 1999 running period achieved aμ+ = 11 659 202(14)(6) x 10-10 (1.3 ppm) and differed from the most precise theory evaluation by 2.6 standard deviations. Considerable additional data has already been obtained in 2000 and 2001 and the analysis of this data is proceeding well. Intense theoretical activity has also taken place ranging from suggestions of the new physics which could account for the deviation to careful re-examination of the standard model contributions themselves. Recently, a re-evaluation of the pion pole contribution to the hadronic light-by-light process exposed a sign error in earlier studies used in the standard theory. With this correction incorporated, experiment and theory disagree by a modest 1.6 standard deviations.

  12. The horizon line, linear perspective, interposition, and background brightness as determinants of the magnitude of the pictorial moon illusion.

    PubMed

    Jones, Stephanie A H; Wilson, Alexander E

    2009-01-01

    A total of 110 undergraduate students participated in a series of three experiments that explored the magnitude of the moon illusion in pictures. Experiment 1 examined the role of the number and salience of depth cues and background brightness. Experiment 2 examined the role of the horizon line, linear perspective, interposition, and background brightness. In Experiment 3, comparative distance judgments of the moon as a function of linear perspective, interposition, and the size of the standard moon were obtained. The magnitude of the moon illusion increased as a function of the number and salience of depth cues and changes in background brightness. Experiment 2 failed to support the role of the horizon line in affecting the illusion. Experiment 3 provided additional support for the illusory distance component of the moon illusion.

  13. NIST Efforts to Quality-Assure Gunpowder Measurements

    NASA Technical Reports Server (NTRS)

    MacCrehan, William A.; Reardon, Michelle R.

    2000-01-01

    In the past few years, the National Institute for Standards and Technology (NIST) has been promoting the idea of quantitatively determining the additives in smokeless gunpowder using micellar capillary electrophoresis as a means of investigating the criminal use of hand guns and pipe bombs. As a part of this effort, we have evaluated both supercritical fluid and ultrasonic solvent extractions for the quantitative recovery of nitroglycerin (NG), diphenylamine (DPA), N-nitrosodiphenylamine (NnDPA), and ethyl centralite (EC) from gunpowder. Recoveries were evaluated by repeat extraction and matrix spiking experiments. The final extraction protocol provides greater than 95 percent recoveries. To help other researches validate their own analytical method for additive determinations, NIST is exploring the development of a standard reference material, Additives in Smokeless Gunpowder. The evaluated method is being applied to two double-base (NG-containing) powders, one stabilized with diphenylamine and the other with ethyl centralite. As part of this reference material development effort, we are conducting an interlaboratory comparison exercise among the forensic and military gunpowder measurement community.

  14. Command-line cellular electrophysiology for conventional and real-time closed-loop experiments.

    PubMed

    Linaro, Daniele; Couto, João; Giugliano, Michele

    2014-06-15

    Current software tools for electrophysiological experiments are limited in flexibility and rarely offer adequate support for advanced techniques such as dynamic clamp and hybrid experiments, which are therefore limited to laboratories with a significant expertise in neuroinformatics. We have developed lcg, a software suite based on a command-line interface (CLI) that allows performing both standard and advanced electrophysiological experiments. Stimulation protocols for classical voltage and current clamp experiments are defined by a concise and flexible meta description that allows representing complex waveforms as a piece-wise parametric decomposition of elementary sub-waveforms, abstracting the stimulation hardware. To perform complex experiments lcg provides a set of elementary building blocks that can be interconnected to yield a large variety of experimental paradigms. We present various cellular electrophysiological experiments in which lcg has been employed, ranging from the automated application of current clamp protocols for characterizing basic electrophysiological properties of neurons, to dynamic clamp, response clamp, and hybrid experiments. We finally show how the scripting capabilities behind a CLI are suited for integrating experimental trials into complex workflows, where actual experiment, online data analysis and computational modeling seamlessly integrate. We compare lcg with two open source toolboxes, RTXI and RELACS. We believe that lcg will greatly contribute to the standardization and reproducibility of both simple and complex experiments. Additionally, on the long run the increased efficiency due to a CLI will prove a great benefit for the experimental community. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Event-driven, pattern-based methodology for cost-effective development of standardized personal health devices.

    PubMed

    Martínez-Espronceda, Miguel; Trigo, Jesús D; Led, Santiago; Barrón-González, H Gilberto; Redondo, Javier; Baquero, Alfonso; Serrano, Luis

    2014-11-01

    Experiences applying standards in personal health devices (PHDs) show an inherent trade-off between interoperability and costs (in terms of processing load and development time). Therefore, reducing hardware and software costs as well as time-to-market is crucial for standards adoption. The ISO/IEEE11073 PHD family of standards (also referred to as X73PHD) provides interoperable communication between PHDs and aggregators. Nevertheless, the responsibility of achieving inexpensive implementations of X73PHD in limited resource microcontrollers falls directly on the developer. Hence, the authors previously presented a methodology based on patterns to implement X73-compliant PHDs into devices with low-voltage low-power constraints. That version was based on multitasking, which required additional features and resources. This paper therefore presents an event-driven evolution of the patterns-based methodology for cost-effective development of standardized PHDs. The results of comparing between the two versions showed that the mean values of decrease in memory consumption and cycles of latency are 11.59% and 45.95%, respectively. In addition, several enhancements in terms of cost-effectiveness and development time can be derived from the new version of the methodology. Therefore, the new approach could help in producing cost-effective X73-compliant PHDs, which in turn could foster the adoption of standards. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Influence of weight and type of planting material on fruit quality and its heterogeneity in pineapple [Ananas comosus (L.) Merrill].

    PubMed

    Fassinou Hotegni, V Nicodème; Lommen, Willemien J M; Agbossou, Euloge K; Struik, Paul C

    2014-01-01

    Cultural practices can affect the quality of pineapple fruits and its variation. The objectives of this study were to investigate (a) effects of weight class and type of planting material on fruit quality, heterogeneity in quality and proportion and yield of fruits meeting European export standards, and (b) the improvement in quality, proportion and yield of fruits meeting export standards when flowering was induced at optimum time. Experiments were conducted in Benin with cvs Sugarloaf (a Perola type) and Smooth Cayenne. In cv. Sugarloaf, experimental factors were weight class of planting material (light, mixed, heavy) and time of flowering induction (farmers', optimum) (Experiment 1). In cv. Smooth Cayenne an additional experimental factor was the type of planting material (hapas, ground suckers, a mixture of the two) (Experiment 2). Fruits from heavy planting material had higher infructescence and fruit weights, longer infructescences, shorter crowns, and smaller crown: infructescence length than fruits from light planting material. The type of planting material in Experiment 2 did not significantly affect fruit quality except crown length: fruits from hapas had shorter crowns than those from ground suckers. Crops from heavy planting material had a higher proportion and yield of fruits meeting export standards than those from other weight classes in Experiment 1 only; also the type of planting material in Experiment 2 did not affect these variates. Heterogeneity in fruit quality was usually not reduced by selecting only light or heavy planting material instead of mixing weights; incidentally the coefficient of variation was significantly reduced in fruits from heavy slips only. Heterogeneity was also not reduced by not mixing hapas and ground suckers. Flowering induction at optimum time increased the proportion and yield of fruits meeting export standards in fruits from light and mixed slip weights and in those from the mixture of heavy hapas plus ground suckers.

  17. Influence of weight and type of planting material on fruit quality and its heterogeneity in pineapple [Ananas comosus (L.) Merrill

    PubMed Central

    Fassinou Hotegni, V. Nicodème; Lommen, Willemien J. M.; Agbossou, Euloge K.; Struik, Paul C.

    2015-01-01

    Cultural practices can affect the quality of pineapple fruits and its variation. The objectives of this study were to investigate (a) effects of weight class and type of planting material on fruit quality, heterogeneity in quality and proportion and yield of fruits meeting European export standards, and (b) the improvement in quality, proportion and yield of fruits meeting export standards when flowering was induced at optimum time. Experiments were conducted in Benin with cvs Sugarloaf (a Perola type) and Smooth Cayenne. In cv. Sugarloaf, experimental factors were weight class of planting material (light, mixed, heavy) and time of flowering induction (farmers', optimum) (Experiment 1). In cv. Smooth Cayenne an additional experimental factor was the type of planting material (hapas, ground suckers, a mixture of the two) (Experiment 2). Fruits from heavy planting material had higher infructescence and fruit weights, longer infructescences, shorter crowns, and smaller crown: infructescence length than fruits from light planting material. The type of planting material in Experiment 2 did not significantly affect fruit quality except crown length: fruits from hapas had shorter crowns than those from ground suckers. Crops from heavy planting material had a higher proportion and yield of fruits meeting export standards than those from other weight classes in Experiment 1 only; also the type of planting material in Experiment 2 did not affect these variates. Heterogeneity in fruit quality was usually not reduced by selecting only light or heavy planting material instead of mixing weights; incidentally the coefficient of variation was significantly reduced in fruits from heavy slips only. Heterogeneity was also not reduced by not mixing hapas and ground suckers. Flowering induction at optimum time increased the proportion and yield of fruits meeting export standards in fruits from light and mixed slip weights and in those from the mixture of heavy hapas plus ground suckers. PMID:25653659

  18. keV-Scale sterile neutrino sensitivity estimation with time-of-flight spectroscopy in KATRIN using self-consistent approximate Monte Carlo

    NASA Astrophysics Data System (ADS)

    Steinbrink, Nicholas M. N.; Behrens, Jan D.; Mertens, Susanne; Ranitzsch, Philipp C.-O.; Weinheimer, Christian

    2018-03-01

    We investigate the sensitivity of the Karlsruhe Tritium Neutrino Experiment (KATRIN) to keV-scale sterile neutrinos, which are promising dark matter candidates. Since the active-sterile mixing would lead to a second component in the tritium β-spectrum with a weak relative intensity of order sin ^2θ ≲ 10^{-6}, additional experimental strategies are required to extract this small signature and to eliminate systematics. A possible strategy is to run the experiment in an alternative time-of-flight (TOF) mode, yielding differential TOF spectra in contrast to the integrating standard mode. In order to estimate the sensitivity from a reduced sample size, a new analysis method, called self-consistent approximate Monte Carlo (SCAMC), has been developed. The simulations show that an ideal TOF mode would be able to achieve a statistical sensitivity of sin ^2θ ˜ 5 × 10^{-9} at one σ , improving the standard mode by approximately a factor two. This relative benefit grows significantly if additional exemplary systematics are considered. A possible implementation of the TOF mode with existing hardware, called gated filtering, is investigated, which, however, comes at the price of a reduced average signal rate.

  19. Experiences of Stigma and Discrimination among Caregivers of Persons with Schizophrenia in China: A Field Survey

    PubMed Central

    Yin, Yi; Zhang, Weijun; Hu, Zhenyu; Jia, Fujun; Li, Yafang; Xu, Huiwen; Zhao, Shuliang; Guo, Jing; Tian, Donghua; Qu, Zhiyong

    2014-01-01

    In China, caregivers for family members with schizophrenia play an important role in treatment and recovery but may experience stigma and discrimination simply because of their family relationship. The object of this study was to measure the degrees and correlates of stigma and discrimination experiences among this group. Four hundred twenty-seven caregivers participated in this hospital-based and cross-sectional study in Ningbo and Guangzhou, China. Data were collected by trained interviewers using fixed questionnaires. Stigma and discrimination experiences were measured by the Modified Consumer Experiences of Stigma Questionnaire (MCESQ). Caregivers’ social support was measured by the Social Support Rating Scale. Parametric analysis, nonparametric analysis and multivariate linear regression were used. The mean (SD) score of MCESQ was 2.44(0.45), 2.91(0.71) for stigma experiences and 1.97(0.37) for discrimination experiences on a five-point score (“1 = never” and “5 = very often”). Approximately 65% of caregivers reported that they tried to conceal their family members’ illness, and 71% lacked the support of friends. The experience of stigma was significantly negatively associated with the perceived social support of caregivers (standard β = −0.2,p<0.001). Caregivers who were children of the patients experienced fewer stigmas than other (standard β = −0.18, p<0.001). Urban residence (standard β = −0.12, p<0.01) and patients did not complete primary school education (standard β = −0.13, p<0.01) were negatively related with stigmas. In addition, stigma and discrimination was more experienced in Zhejiang than in Guangdong (p<0.05). In conclusion, this study performed that caregivers of people with schizophrenia in China experienced general stigmas and rare discrimination and found the relations with social support, kinship, patient’s educational level and regional differences. More interventions and supports should been given to caregivers who are lack of social support, who live in rural area and who are the patients’ parents, spouses or siblings. PMID:25259732

  20. Experiences of stigma and discrimination among caregivers of persons with schizophrenia in China: a field survey.

    PubMed

    Yin, Yi; Zhang, Weijun; Hu, Zhenyu; Jia, Fujun; Li, Yafang; Xu, Huiwen; Zhao, Shuliang; Guo, Jing; Tian, Donghua; Qu, Zhiyong

    2014-01-01

    In China, caregivers for family members with schizophrenia play an important role in treatment and recovery but may experience stigma and discrimination simply because of their family relationship. The object of this study was to measure the degrees and correlates of stigma and discrimination experiences among this group. Four hundred twenty-seven caregivers participated in this hospital-based and cross-sectional study in Ningbo and Guangzhou, China. Data were collected by trained interviewers using fixed questionnaires. Stigma and discrimination experiences were measured by the Modified Consumer Experiences of Stigma Questionnaire (MCESQ). Caregivers' social support was measured by the Social Support Rating Scale. Parametric analysis, nonparametric analysis and multivariate linear regression were used. The mean (SD) score of MCESQ was 2.44(0.45), 2.91(0.71) for stigma experiences and 1.97(0.37) for discrimination experiences on a five-point score ("1 = never" and "5 = very often"). Approximately 65% of caregivers reported that they tried to conceal their family members' illness, and 71% lacked the support of friends. The experience of stigma was significantly negatively associated with the perceived social support of caregivers (standard β = -0.2,p<0.001). Caregivers who were children of the patients experienced fewer stigmas than other (standard β = -0.18, p<0.001). Urban residence (standard β = -0.12, p<0.01) and patients did not complete primary school education (standard β = -0.13, p<0.01) were negatively related with stigmas. In addition, stigma and discrimination was more experienced in Zhejiang than in Guangdong (p<0.05). In conclusion, this study performed that caregivers of people with schizophrenia in China experienced general stigmas and rare discrimination and found the relations with social support, kinship, patient's educational level and regional differences. More interventions and supports should been given to caregivers who are lack of social support, who live in rural area and who are the patients' parents, spouses or siblings.

  1. Solid matrix transformation and tracer addition using molten ammonium bifluoride salt as a sample preparation method for laser ablation inductively coupled plasma mass spectrometry.

    PubMed

    Grate, Jay W; Gonzalez, Jhanis J; O'Hara, Matthew J; Kellogg, Cynthia M; Morrison, Samuel S; Koppenaal, David W; Chan, George C-Y; Mao, Xianglei; Zorba, Vassilia; Russo, Richard E

    2017-09-08

    Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standards.

  2. High hunger state increases olfactory sensitivity to neutral but not food odors.

    PubMed

    Stafford, Lorenzo D; Welbeck, Kimberley

    2011-01-01

    Understanding how hunger state relates to olfactory sensitivity has become more urgent due to their possible role in obesity. In 2 studies (within-subjects: n = 24, between-subjects: n = 40), participants were provided with lunch before (satiated state) or after (nonsatiated state) testing and completed a standardized olfactory threshold test to a neutral odor (Experiments 1 and 2) and discrimination test to a food odor (Experiment 2). Experiment 1 revealed that olfactory sensitivity was greater in the nonsatiated versus satiated state, with additionally increased sensitivity for the low body mass index (BMI) compared with high BMI group. Experiment 2 replicated this effect for neutral odors, but in the case of food odors, those in a satiated state had greater acuity. Additionally, whereas the high BMI group had higher acuity to food odors in the satiated versus nonsatiated state, no such differences were found for the low BMI group. The research here is the first to demonstrate how olfactory acuity changes as a function of hunger state and relatedness of odor to food and that BMI can predict differences in olfactory sensitivity.

  3. Bioanalytical method development and validation for the determination of glycine in human cerebrospinal fluid by ion-pair reversed-phase liquid chromatography-tandem mass spectrometry.

    PubMed

    Jiang, Jian; James, Christopher A; Wong, Philip

    2016-09-05

    A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. [Standard addition determination of impurities in Na2CrO4 by ICP-AES].

    PubMed

    Wang, Li-ping; Feng, Hai-tao; Dong, Ya-ping; Peng, Jiao-yu; Li, Wu; Shi, Hai-qin; Wang, Yong

    2015-02-01

    Coupled plasma atomic emission spectrometry (ICP-AES) was used to determine the trace impurities of Ca, Mg, Al, Fe and Si in industrial sodium chromate. Wavelengths of 167.079, 393.366, 259.940, 279.533 and 251.611 nm were selected as analytical lines for the determination of Al, Ca, Fe, Mg and Si, respectively. The analytical errors can be eliminated by adjusting the determined solution with high pure hydrochloric acid. Standard addition method was used to eliminate matrix effects. The linear correlation, detection limit, precision and recovery for the concerned trace impurities have been examined. The effect of standard addition method on the accuracy for the determination under the selected analytical lines has been studied in detail. The results show that the linear correlations of standard curves were very good (R2 = 0.9988 to 0.9996) under the determined conditions. Detection limits of these trace impurities were in the range of 0.0134 to 0.0280 mg x L(-1). Sample recoveries were within 97.30% to 107.50%, and relative standard deviations were lower than 5.86% for eleven repeated determinations. The detection limits and accuracies established by the experiment can meet the analytical requirements and the analytic procedure was used to determine trace impurities in sodium chromate by ion membrane electrolysis technique successfully. Due to sodium chromate can be changed into sodium dichromate and chromic acid by adding acids, the established method can be further used to monitor trace impurities in these compounds or other hexavalent chromium compounds.

  5. Growth rate measurement in free jet experiments

    NASA Astrophysics Data System (ADS)

    Charpentier, Jean-Baptiste; Renoult, Marie-Charlotte; Crumeyrolle, Olivier; Mutabazi, Innocent

    2017-07-01

    An experimental method was developed to measure the growth rate of the capillary instability for free liquid jets. The method uses a standard shadow-graph imaging technique to visualize a jet, produced by extruding a liquid through a circular orifice, and a statistical analysis of the entire jet. The analysis relies on the computation of the standard deviation of a set of jet profiles, obtained in the same experimental conditions. The principle and robustness of the method are illustrated with a set of emulated jet profiles. The method is also applied to free falling jet experiments conducted for various Weber numbers and two low-viscosity solutions: a Newtonian and a viscoelastic one. Growth rate measurements are found in good agreement with linear stability theory in the Rayleigh's regime, as expected from previous studies. In addition, the standard deviation curve is used to obtain an indirect measurement of the initial perturbation amplitude and to identify beads on a string structure on the jet. This last result serves to demonstrate the capability of the present technique to explore in the future the dynamics of viscoelastic liquid jets.

  6. A Genome-Wide Association Analysis Reveals Epistatic Cancellation of Additive Genetic Variance for Root Length in Arabidopsis thaliana.

    PubMed

    Lachowiec, Jennifer; Shen, Xia; Queitsch, Christine; Carlborg, Örjan

    2015-01-01

    Efforts to identify loci underlying complex traits generally assume that most genetic variance is additive. Here, we examined the genetics of Arabidopsis thaliana root length and found that the genomic narrow-sense heritability for this trait in the examined population was statistically zero. The low amount of additive genetic variance that could be captured by the genome-wide genotypes likely explains why no associations to root length could be found using standard additive-model-based genome-wide association (GWA) approaches. However, as the broad-sense heritability for root length was significantly larger, and primarily due to epistasis, we also performed an epistatic GWA analysis to map loci contributing to the epistatic genetic variance. Four interacting pairs of loci were revealed, involving seven chromosomal loci that passed a standard multiple-testing corrected significance threshold. The genotype-phenotype maps for these pairs revealed epistasis that cancelled out the additive genetic variance, explaining why these loci were not detected in the additive GWA analysis. Small population sizes, such as in our experiment, increase the risk of identifying false epistatic interactions due to testing for associations with very large numbers of multi-marker genotypes in few phenotyped individuals. Therefore, we estimated the false-positive risk using a new statistical approach that suggested half of the associated pairs to be true positive associations. Our experimental evaluation of candidate genes within the seven associated loci suggests that this estimate is conservative; we identified functional candidate genes that affected root development in four loci that were part of three of the pairs. The statistical epistatic analyses were thus indispensable for confirming known, and identifying new, candidate genes for root length in this population of wild-collected A. thaliana accessions. We also illustrate how epistatic cancellation of the additive genetic variance explains the insignificant narrow-sense and significant broad-sense heritability by using a combination of careful statistical epistatic analyses and functional genetic experiments.

  7. Influence of diet with kale on lipid peroxides and malondialdehyde levels in blood serum of laboratory rats over intoxication with paraquat.

    PubMed

    Sikora, Elżbieta; Bodziarczyk, Izabela

    2013-01-01

    Organism's lipid peroxidation is one of the most often examined and known physiological process evoked by free radicals. It concerns oxidation reaction of unsaturated fatty acid and/or other lipids leading to lipid oxidation products (LOP), which as a result of further changes generate among others the malondialdehyde molecules. The aim of the work was an estimation if raw or cooked kale addition to rat's diet influences antioxidant defense efficiency in their organisms in comparison to rats fed with standard AIN-93G diet. The experiment was conducted with 36 Wistar strain, male rats over 21 days. The rats were divided into 3 groups (each 12 stuck) which were fed with: standard diet AIN-93G (2 groups), AIN-93G diet with 10% addition of raw kale (2 groups), and AIN-93G with 10% addition of cooked lyophilised kale. The total content of polyphenols (FC method) and antioxidant activity (ABTS+•) were previously determined in raw and then in cooked kale. On the 20th day of experiment, half of rats (6 stuck) of each kind of the diet were injected intraperitoneally by the solution of paraquat (PQ) in physiological salt to evoke the oxidative stress. The next day animals were stunned and blood from their hearts was sampled. In the obtained serum, the levels of lipid oxidation products (LOP) and malondialdehyde (MDA) were assessed. It was observed that in blood serum of rats fed with modified diet with raw and cooked lyophilised kale addition the lipid oxides level was lower in comparison to control group fed with standard diet (p < 0.05). It was found that intoxication with paraquat caused growth of MDA and LOP levels in blood serum of all rats in comparison to not intoxicated groups but that growth was the lowest in group fed diet with cooked kale addition. Diet with kale, both raw and cooked, efficiently inhibited the lipid peroxidation process in rats' organisms, ongoing during natural metabolism and during evoked oxidative stress.

  8. A globally efficient means of distributing UTC time and frequency through GPS

    NASA Technical Reports Server (NTRS)

    Kusters, John A.; Giffard, Robin P.; Cutler, Leonard S.; Allan, David W.; Miranian, Mihran

    1995-01-01

    Time and frequency outputs comparable in quality to the best laboratories have been demonstrated on an integrated system suitable for field application on a global basis. The system measures the time difference between 1 pulse-per-second (pps) signals derived from local primary frequency standards and from a multi-channel GPS C/A receiver. The measured data is processed through optimal SA Filter algorithms that enhance both the stability and accuracy of GPS timing signals. Experiments were run simultaneously at four different sites. Even with large distances between sites, the overall results show a high degree of cross-correlation of the SA noise. With sufficiently long simultaneous measurement sequences, the data shows that determination of the difference in local frequency from an accepted remote standard to better than 1 x 10(exp -14) is possible. This method yields frequency accuracy, stability, and timing stability comparable to that obtained with more conventional common-view experiments. In addition, this approach provides UTC(USNO MC) in real time to an accuracy better than 20 ns without the problems normally associated with conventional common-view techniques. An experimental tracking loop was also set up to demonstrate the use of enhanced GPS for dissemination of UTC(USNO MC) over a wide geographic area. Properly disciplining a cesium standard with a multi-channel GPS receiver, with additional input from USNO, has been found to permit maintaining a timing precision of better than 10 ns between Palo Alto, CA and Washington, DC.

  9. On the relation between personality and job performance of airline pilots.

    PubMed

    Hormann, H J; Maschke, P

    1996-01-01

    The validity of a personality questionnaire for the prediction of job success of airline pilots is compared to validities of a simulator checkflight and of flying experience data. During selection, 274 pilots applying for employment with a European charter airline were examined with a multidimensional personality questionnaire (Temperature Structure Scales; TSS). Additionally, the applicants were graded in a simulator checkflight. On the basis of training records, the pilots were classified as performing at standard or below standard after about 3 years of employment in the hiring company. In a multiple-regression model, this dichotomous criterion for job success can be predicted with 73.8% accuracy through the simulator checkflight and flying experience prior to employment. By adding the personality questionnaire to the regression equation, the number of correct classifications increases to 79.3%. On average, successful pilots score substantially higher on interpersonal scales and lower on emotional scales of the TSS.

  10. Organic carbonates: experiment and ab initio calculations for prediction of thermochemical properties.

    PubMed

    Verevkin, Sergey P; Emel'yanenko, Vladimir N; Kozlova, Svetlana A

    2008-10-23

    This work has been undertaken in order to obtain data on thermodynamic properties of organic carbonates and to revise the group-additivity values necessary for predicting their standard enthalpies of formation and enthalpies of vaporization. The standard molar enthalpies of formation of dibenzyl carbonate, tert-butyl phenyl carbonate, and diphenyl carbonate were measured using combustion calorimetry. Molar enthalpies of vaporization of these compounds were obtained from the temperature dependence of the vapor pressure measured by the transpiration method. Molar enthalpy of sublimation of diphenyl carbonate was measured in the same way. Ab initio calculations of molar enthalpies of formation of organic carbonates have been performed using the G3MP2 method, and results are in excellent agreement with the available experiment. Then the group-contribution method has been developed to predict values of the enthalpies of formation and enthalpies of vaporization of organic carbonates.

  11. Adults Can Be Trained to Acquire Synesthetic Experiences

    PubMed Central

    Bor, Daniel; Rothen, Nicolas; Schwartzman, David J.; Clayton, Stephanie; Seth, Anil K.

    2014-01-01

    Synesthesia is a condition where presentation of one perceptual class consistently evokes additional experiences in different perceptual categories. Synesthesia is widely considered a congenital condition, although an alternative view is that it is underpinned by repeated exposure to combined perceptual features at key developmental stages. Here we explore the potential for repeated associative learning to shape and engender synesthetic experiences. Non-synesthetic adult participants engaged in an extensive training regime that involved adaptive memory and reading tasks, designed to reinforce 13 specific letter-color associations. Following training, subjects exhibited a range of standard behavioral and physiological markers for grapheme-color synesthesia; crucially, most also described perceiving color experiences for achromatic letters, inside and outside the lab, where such experiences are usually considered the hallmark of genuine synesthetes. Collectively our results are consistent with developmental accounts of synesthesia and illuminate a previously unsuspected potential for new learning to shape perceptual experience, even in adulthood. PMID:25404369

  12. Electrode spanning with partial tripolar stimulation mode in cochlear implants.

    PubMed

    Wu, Ching-Chih; Luo, Xin

    2014-12-01

    The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.

  13. Finding Your Way out of the Forest without a Trail of Bread Crumbs: Development and Evaluation of Two Novel Displays of Forest Plots

    ERIC Educational Resources Information Center

    Schild, Anne H. E.; Voracek, Martin

    2015-01-01

    Research has shown that forest plots are a gold standard in the visualization of meta-analytic results. However, research on the general interpretation of forest plots and the role of researchers' meta-analysis experience and field of study is still unavailable. Additionally, the traditional display of effect sizes, confidence intervals, and…

  14. Evaluation of the Level of Students with Visual Impairments in Turkey in Terms of the Concepts of Mobility Prerequisites (Body Plane/Traffic)

    ERIC Educational Resources Information Center

    Altunay Arslantekin, Banu

    2017-01-01

    Purpose: Visually impaired people are weak in terms of their learning words and concepts by hearing them and their experience of the world with their bodies. In addition to developing a standardized assessment tool in the Development of Orientation and Mobility Skill Assessment Tool (OMSAT/YOBDA) for Visually Impaired Students Project, supported…

  15. University NanoSat Program: AggieSat3

    DTIC Science & Technology

    2009-06-01

    commercially available product for stereo machine vision developed by Point Grey Research. The current binocular BumbleBee2® system incorporates two...and Fellow of the American Society of Mechanical Engineers (ASME) in 1997. She was awarded the 2007 J. Leland "Lee" Atwood Award from the ASEE...AggieSat2 satellite programs. Additional experience gained in the area of drawing standards, machining capabilities, solid modeling, safety

  16. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE.

    PubMed

    Kowalik, Grzegorz T; Knight, Daniel S; Steeden, Jennifer A; Tann, Oliver; Odille, Freddy; Atkinson, David; Taylor, Andrew; Muthurangu, Vivek

    2015-02-01

    To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction. © 2014 Wiley Periodicals, Inc.

  17. Qualification testing and electrical measurement experience: A manufacturer's view

    NASA Astrophysics Data System (ADS)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-11-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  18. Qualification testing and electrical measurement experience: A manufacturer's view

    NASA Technical Reports Server (NTRS)

    Arnett, J. C.; Cooley, J. E.; Wingert, T. L.

    1983-01-01

    ARCO Solar's experiences as a participant in an industry-utility-government environmental qualification team examining photovoltaic devices are discussed. Included is an assessment of the applicability, completeness and appropriateness of the testing procedures and of the acceptance criteria for megawatt-sized procurements for utilities. Like the stand-alone users, the utility industry is interested in obtaining low costs, but additional concerns exist related to reliability and durability, safety, grounding and overall system criteria including performance prediction (related to output power acceptance testing), power quality and dispatchability. For purposes of this first major purchase of photovoltaic modules and panels by the utility industry, there was a carry-over of the JPL specifications. The need exists for futher development, assessement, and selection of qualification and testing standards and evaluation criteria specifically addressing these additional concerns for utility-connected PV power-plant applications.

  19. A Nutritional Evaluation of the Experimental Food Service System at Travis AFB, California

    DTIC Science & Technology

    1974-07-01

    food service experiment at Travis AFB, California was performed. The purpose of this evaluation was to determine the levels of selected nutrient elements provided by these meals and to compare them with established nutritional standards. In addition, the data provide for a comparison of the nutritional profiles of the meals served in the dining halls with those served in two new experimental food outlets. It is concluded that the meals served during the experiment were nutritionally adequate as compared to Air Force requirements, and that the meals served in the two new

  20. Introducing a true internal standard for the Comet assay to minimize intra- and inter-experiment variability in measures of DNA damage and repair

    PubMed Central

    Zainol, Murizal; Stoute, Julia; Almeida, Gabriela M.; Rapp, Alexander; Bowman, Karen J.; Jones, George D. D.

    2009-01-01

    The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA. PMID:19828597

  1. A standardized test battery for the study of synesthesia

    PubMed Central

    Eagleman, David M.; Kagan, Arielle D.; Nelson, Stephanie S.; Sagaram, Deepak; Sarma, Anand K.

    2014-01-01

    Synesthesia is an unusual condition in which stimulation of one modality evokes sensation or experience in another modality. Although discussed in the literature well over a century ago, synesthesia slipped out of the scientific spotlight for decades because of the difficulty in verifying and quantifying private perceptual experiences. In recent years, the study of synesthesia has enjoyed a renaissance due to the introduction of tests that demonstrate the reality of the condition, its automatic and involuntary nature, and its measurable perceptual consequences. However, while several research groups now study synesthesia, there is no single protocol for comparing, contrasting and pooling synesthetic subjects across these groups. There is no standard battery of tests, no quantifiable scoring system, and no standard phrasing of questions. Additionally, the tests that exist offer no means for data comparison. To remedy this deficit we have devised the Synesthesia Battery. This unified collection of tests is freely accessible online (http://www.synesthete.org). It consists of a questionnaire and several online software programs, and test results are immediately available for use by synesthetes and invited researchers. Performance on the tests is quantified with a standard scoring system. We introduce several novel tests here, and offer the software for running the tests. By presenting standardized procedures for testing and comparing subjects, this endeavor hopes to speed scientific progress in synesthesia research. PMID:16919755

  2. Quantifying stream nutrient uptake from ambient to saturation with instantaneous tracer additions

    NASA Astrophysics Data System (ADS)

    Covino, T. P.; McGlynn, B. L.; McNamara, R.

    2009-12-01

    Stream nutrient tracer additions and spiraling metrics are frequently used to quantify stream ecosystem behavior. However, standard approaches limit our understanding of aquatic biogeochemistry. Specifically, the relationship between in-stream nutrient concentration and stream nutrient spiraling has not been characterized. The standard constant rate (steady-state) approach to stream spiraling parameter estimation, either through elevating nutrient concentration or adding isotopically labeled tracers (e.g. 15N), provides little information regarding the stream kinetic curve that represents the uptake-concentration relationship analogous to the Michaelis-Menten curve. These standard approaches provide single or a few data points and often focus on estimating ambient uptake under the conditions at the time of the experiment. Here we outline and demonstrate a new method using instantaneous nutrient additions and dynamic analyses of breakthrough curve (BTC) data to characterize the full relationship between spiraling metrics and nutrient concentration. We compare the results from these dynamic analyses to BTC-integrated, and standard steady-state approaches. Our results indicate good agreement between these three approaches but we highlight the advantages of our dynamic method. Specifically, our new dynamic method provides a cost-effective and efficient approach to: 1) characterize full concentration-spiraling metric curves; 2) estimate ambient spiraling metrics; 3) estimate Michaelis-Menten parameters maximum uptake (Umax) and the half-saturation constant (Km) from developed uptake-concentration kinetic curves, and; 4) measure dynamic nutrient spiraling in larger rivers where steady-state approaches are impractical.

  3. Improving planning, design, reporting and scientific quality of animal experiments by using the Gold Standard Publication Checklist, in addition to the ARRIVE guidelines.

    PubMed

    Hooijmans, Carlijn R; de Vries, Rob; Leenaars, Marlies; Curfs, Jo; Ritskes-Hoitinga, Merel

    2011-03-01

    Several studies have demonstrated serious omissions in the way research that use animals is reported. In order to improve the quality of reporting of animal experiments, the Animals in research: reporting in vivo experiments (ARRIVE) Guidelines were published in the British Journal of Pharmacology in August 2010. However, not only the quality of reporting of completed animal studies needs to be improved, but also the design and execution of new experiments. With both these goals in mind, we published the Gold Standard Publication Checklist (GSPC) in May 2010, a few months before the ARRIVE guidelines appeared. In this letter, we compare the GSPC checklist with the ARRIVE Guidelines. The GSPC describes certain items in more detail, which makes it both easier to use when designing and conducting an experiment and particularly suitable for making systematic reviews of animal studies more feasible. In order to improve not only the reporting but also the planning, design, execution and thereby, the scientific quality of animal experiments, we strongly recommend to all scientists involved in animal experimentation and to editors of journals publishing animal studies to take a closer look at the contents of both the ARRIVE guidelines and GSPC, and select the set of guidelines which is most appropriate for their particular situation. © 2011 The Authors. British Journal of Pharmacology © 2011 The British Pharmacological Society.

  4. Experiences of healthcare professionals of having their significant other admitted to an acute care facility: a qualitative systematic review.

    PubMed

    Sabyani, Hussamaldeen; Wiechula, Richard; Magarey, Judy; Donnelly, Frank

    2017-05-01

    Most healthcare professionals at some time will experience having a significant other admitted to an acute care hospital. The knowledge and understanding that these individuals possess because of their professional practice can potentially alter this experience. Expectations of staff and other family members (FMs) can potentially increase the burden on these health professionals. All FMs of patients should have their needs and expectations considered; however, this review specifically addresses what may be unique for healthcare professionals. To synthesize the qualitative evidence on the experiences of healthcare professionals when their significant others are admitted to an acute care hospital. The current review considered studies reporting the experiences of healthcare professionals, specifically registered nurses (RNs) and physicians. The experiences of RNs and physicians when a significant other is admitted to an acute care facility. Qualitative studies that have examined the phenomenon of interest including, but not limited to, designs such as phenomenology and grounded theory. The search strategy aimed to find both published and unpublished studies with no date restrictions. Only studies published in English were considered for inclusion in this review. Qualitative papers selected for retrieval were assessed using the standardized critical appraisal instrument from the Joanna Briggs Institute Qualitative Assessment and Review Instrument (JBI-QARI). Data were extracted from the seven included papers using the standardized data extraction tool from JBI-QARI. The data were synthesized using the JBI approach to meta-synthesis by meta-aggregation using the JBI-QARI software and methods. Seven studies of moderate quality were included in the review. Forty findings were extracted and aggregated to create 10 categories, from which five synthesized findings were derived: CONCLUSION: In contrast to "lay" FMs, health professionals possess additional knowledge and understanding that alter their perceptions and expectations, and the expectations others have of them. This knowledge and understanding can be an advantage in navigating a complex health system but may also result in an additional burden such as role conflict.

  5. Search for sterile neutrino oscillations in muon neutrino disappearance at MINOS/MINOS+

    NASA Astrophysics Data System (ADS)

    Todd, Jacob; Minos+ Collaboration

    2017-01-01

    A wide variety of neutrino oscillation phenomena are well-described by the standard three-flavour neutrino model, but some anomalies exist. The LSND and MiniBooNE experiments have measured electron antineutrino appearance in excess of standard oscillation predictions, which points to the possibility of a sterile neutrino with higher mass than the presently known states. MINOS, a two-detector, long-baseline neutrino oscillation experiment, was optimized for the measurement of muon neutrino disappearance in the NuMI neutrino beam. A sterile neutrino responsible for the LSND and MiniBooNE excesses would cause distortions in the charged current and neutral current MINOS spectra, which permits the search for sterile neutrinos at MINOS. In close collaboration with the Daya Bay reactor neutrino experiment, MINOS has placed strong constraints on the sterile neutrino parameter space for a model with one additional sterile neutrino. Further, the extension of data collection with MINOS+, which samples the NuMI beam in a medium energy configuration, markedly increases the sensitivity of the combined MINOS and MINOS+ sample to a 3+1-flavour sterile neutrino model.

  6. Development of high performance hybrid rocket fuels

    NASA Astrophysics Data System (ADS)

    Zaseck, Christopher R.

    In this document I discuss paraffin fuel combustion and investigate the effects of additives on paraffin entrainment and regression. In general, hybrid rockets offer an economical and safe alternative to standard liquid and solid rockets. However, slow polymeric fuel regression and low combustion efficiency have limited the commercial use of hybrid rockets. Paraffin is a fast burning fuel that has received significant attention in the 2000's and 2010's as a replacement for standard fuels. Paraffin regresses three to four times faster than polymeric fuels due to the entrainment of a surface melt layer. However, further regression rate enhancement over the base paraffin fuel is necessary for widespread hybrid rocket adoption. I use a small scale opposed flow burner to investigate the effect of additives on the combustion of paraffin. Standard additives such as aluminum combust above the flame zone where sufficient oxidizer levels are present. As a result no heat is generated below the flame itself. In small scale opposed burner experiments the effect of limited heat feedback is apparent. Aluminum in particular does not improve the regression of paraffin in the opposed burner. The lack of heat feedback from additive combustion limits the applicability of the opposed burner. In turn, the results obtained in the opposed burner with metal additive loaded hybrid fuels do not match results from hybrid rocket experiments. In addition, nano-scale aluminum increases melt layer viscosity and greatly slows the regression of paraffin in the opposed flow burner. However, the reactive additives improve the regression rate of paraffin in the opposed burner where standard metals do not. At 5 wt.% mechanically activated titanium and carbon (Ti-C) improves the regression rate of paraffin by 47% in the opposed burner. The mechanically activated Ti C likely reacts in or near the melt layer and provides heat feedback below the flame region that results in faster opposed burner regression. In order to examine paraffin/additive combustion in a motor environment, I conducted experiments on well characterized aluminum based additives. In particular, I investigate the influence of aluminum, unpassivated aluminum, milled aluminum/polytetrafluoroethylene (PTFE), and aluminum hydride on the performance of paraffin fuels for hybrid rocket propulsion. I use an optically accessible combustor to examine the performance of the fuel mixtures in terms of characteristic velocity efficiency and regression rate. Each combustor test consumes a 12.7 cm long, 1.9 cm diameter fuel strand under 160 kg/m 2s of oxygen at up to 1.4 MPa. The experimental results indicate that the addition of 5 wt.% 30 mum or 80 nm aluminum to paraffin increases the regression rate by approximately 15% compared to neat paraffin grains. At higher aluminum concentrations and nano-scale particles sizes, the increased melt layer viscosity causes slower regression. Alane and Al/PTFE at 12.5 wt.% increase the regression of paraffin by 21% and 32% respectively. Finally, an aging study indicates that paraffin can protect air and moisture sensitive particles from oxidation. The opposed burner and aluminum/paraffin hybrid rocket experiments show that additives can alter bulk fuel properties, such as viscosity, that regulate entrainment. The general effect of melt layer properties on the entrainment and regression rate of paraffin is not well understood. Improved understanding of how solid additives affect the properties and regression of paraffin is essential to maximize performance. In this document I investigate the effect of melt layer properties on paraffin regression using inert additives. Tests are performed in the optical cylindrical combustor at ˜1 MPa under a gaseous oxygen mass flux of ˜160 kg/m2s. The experiments indicate that the regression rate is proportional to mu0.08rho 0.38kappa0.82. In addition, I explore how to predict fuel viscosity, thermal conductivity, and density prior to testing. Mechanically activated Ti-C and Al/PTFE are examined in the optical combustor. I examine the effect of the reactivity by altering the mill time for the Ti-C and Al/PTFE particles. Mechanical activation of both Ti-C and Al/PTFE improve the regression rate of paraffin more than the unmilled additives. At 12.5 wt.% Al/PTFE milled for 40 minutes regresses 12% faster than the unmilled fuel. Similarly, at 12.5 wt.% 7.5 minute milled Ti C regresses 7% faster than unmilled Ti-C. The reactive particles increase heat transfer to the fuel surface and improve regression. The composition of the combustion products are examined using a particle catcher system in conjunction with visible light and electron microscopy. The exhaust products indicate that the mechanical activation of the Al/PTFE particles cause microexplosions that reduce exhaust particle size. However, the composition of the mechanically activated Al/PTFE products do not indicate more complete combustion. In addition, the mechanically activated and unmilled Ti-C showed no difference in exhaust products.

  7. Use of Baby Isao Simulator and Standardized Parents in Hearing Screening and Parent Counseling Education.

    PubMed

    Alanazi, Ahmad A; Nicholson, Nannette; Atcherson, Samuel R; Franklin, Clifford; Anders, Michael; Nagaraj, Naveen; Franklin, Jennifer; Highley, Patricia

    2016-09-01

    The primary purpose of this study was to test the effect of the combined use of trained standardized parents and a baby simulator on students' hearing screening and parental counseling knowledge and skills. A one-group pretest-posttest quasi-experimental study design was used to assess self-ratings of confidence in knowledge and skills and satisfaction of the educational experience with standardized parents and a baby simulator. The mean age of the 14 audiology students participating in this study was 24.79 years (SD = 1.58). Participants completed a pre- and postevent questionnaire in which they rated their level of confidence for specific knowledge and skills. Six students (2 students in each scenario) volunteered to participate in the infant hearing screening and counseling scenarios, whereas others participated as observers. All participants participated in the briefing and debriefing sessions immediately before and after each of 3 scenarios. After the last scenario, participants were asked to complete a satisfaction survey of their learning experience using simulation and standardized parents. Overall, the pre- and post-simulation event questionnaire revealed a significant improvement in the participants' self-rated confidence levels regarding knowledge and skills. The mean difference between pre- and postevent scores was 0.52 (p < .01). The mean satisfaction level was 4.71 (range = 3.91-5.00; SD = 0.30) based on a Likert scale, where 1 = not satisfied and 5 = very satisfied. The results of this novel educational activity demonstrate the value of using infant hearing screening and parental counseling simulation sessions to enhance student learning. In addition, this study demonstrates the use of simulation and standardized parents as an important pedagogical tool for audiology students. Students experienced a high level of satisfaction with the learning experience.

  8. Developing accreditation for community based surgery: the Irish experience.

    PubMed

    Ní Riain, Ailís; Collins, Claire; O'Sullivan, Tony

    2018-02-05

    Purpose Carrying out minor surgery procedures in the primary care setting is popular with patients, cost effective and delivers at least as good outcomes as those performed in the hospital setting. This paper aims to describe the central role of clinical leadership in developing an accreditation system for general practitioners (GPs) undertaking community-based surgery in the Irish national setting where no mandatory accreditation process currently exists. Design/methodology/approach In all, 24 GPs were recruited to the GP network. Ten pilot standards were developed addressing GPs' experience and training, clinical activity and practice supporting infrastructure and tested, using information and document review, prospective collection of clinical data and a practice inspection visit. Two additional components were incorporated into the project (patient satisfaction survey and self-audit). A multi-modal evaluation was undertaken. A majority of GPs was included at all stages of the project, in line with the principles of action learning. The steering group had a majority of GPs with relevant expertise and representation of all other actors in the minor surgery arena. The GP research network contributed to each stage of the project. The project lead was a GP with minor surgery experience. Quantitative data collected were analysed using Predictive Analytic SoftWare. Krueger's framework analysis approach was used to analyse the qualitative data. Findings A total of 9 GPs achieved all standards at initial review, 14 successfully completed corrective actions and 1 GP did not achieve the required standard. Standards were then amended to reflect findings and a supporting framework was developed. Originality/value The flexibility of the action-learning approach and the clinical leadership design allowed for the development of robust quality standards in a short timeframe.

  9. Exploring ν signals in dark matter detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harnik, Roni; Kopp, Joachim; Machado, Pedro A.N., E-mail: roni@fnal.gov, E-mail: jkopp@fnal.gov, E-mail: accioly@fma.if.usp.br

    2012-07-01

    We investigate standard and non-standard solar neutrino signals in direct dark matter detection experiments. It is well known that even without new physics, scattering of solar neutrinos on nuclei or electrons is an irreducible background for direct dark matter searches, once these experiments reach the ton scale. Here, we entertain the possibility that neutrino interactions are enhanced by new physics, such as new light force carriers (for instance a ''dark photon'') or neutrino magnetic moments. We consider models with only the three standard neutrino flavors, as well as scenarios with extra sterile neutrinos. We find that low-energy neutrino-electron and neutrino-nucleusmore » scattering rates can be enhanced by several orders of magnitude, potentially enough to explain the event excesses observed in CoGeNT and CRESST. We also investigate temporal modulation in these neutrino signals, which can arise from geometric effects, oscillation physics, non-standard neutrino energy loss, and direction-dependent detection efficiencies. We emphasize that, in addition to providing potential explanations for existing signals, models featuring new physics in the neutrino sector can also be very relevant to future dark matter searches, where, on the one hand, they can be probed and constrained, but on the other hand, their signatures could also be confused with dark matter signals.« less

  10. Exploring nu Signals in Dark Matter Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harnik, Roni; Kopp, Joachim; Machado, Pedro A.N.

    2012-02-01

    We investigate standard and non-standard solar neutrino signals in direct dark matter detection experiments. It is well known that even without new physics, scattering of solar neutrinos on nuclei or electrons is an irreducible background for direct dark matter searches, once these experiments each the ton scale. Here, we entertain the possibility that neutrino interactions are enhanced by new physics, such as new light force carriers (for instance a "dark photon") or neutrino magnetic moments. We consider models with only the three standard neutrino flavors, as well as scenarios with extra sterile neutrinos. We find that low-energy neutrino--electron and neutrino--nucleusmore » scattering rates can be enhanced by several orders of magnitude, potentially enough to explain the event excesses observed in CoGeNT and CRESST. We also investigate temporal modulation in these neutrino signals, which can arise from geometric effects, oscillation physics, non-standard neutrino energy loss, and direction-dependent detection efficiencies. We emphasize that, in addition to providing potential explanations for existing signals, models featuring new physics in the neutrino sector can also be very relevant to future dark matter searches, where, on the one hand, they can be probed and constrained, but on the other hand, their signatures could also be confused with dark matter signals.« less

  11. NASA Reverb: Standards-Driven Earth Science Data and Service Discovery

    NASA Astrophysics Data System (ADS)

    Cechini, M. F.; Mitchell, A.; Pilone, D.

    2011-12-01

    NASA's Earth Observing System Data and Information System (EOSDIS) is a core capability in NASA's Earth Science Data Systems Program. NASA's EOS ClearingHOuse (ECHO) is a metadata catalog for the EOSDIS, providing a centralized catalog of data products and registry of related data services. Working closely with the EOSDIS community, the ECHO team identified a need to develop the next generation EOS data and service discovery tool. This development effort relied on the following principles: + Metadata Driven User Interface - Users should be presented with data and service discovery capabilities based on dynamic processing of metadata describing the targeted data. + Integrated Data & Service Discovery - Users should be able to discovery data and associated data services that facilitate their research objectives. + Leverage Common Standards - Users should be able to discover and invoke services that utilize common interface standards. Metadata plays a vital role facilitating data discovery and access. As data providers enhance their metadata, more advanced search capabilities become available enriching a user's search experience. Maturing metadata formats such as ISO 19115 provide the necessary depth of metadata that facilitates advanced data discovery capabilities. Data discovery and access is not limited to simply the retrieval of data granules, but is growing into the more complex discovery of data services. These services include, but are not limited to, services facilitating additional data discovery, subsetting, reformatting, and re-projecting. The discovery and invocation of these data services is made significantly simpler through the use of consistent and interoperable standards. By utilizing an adopted standard, developing standard-specific adapters can be utilized to communicate with multiple services implementing a specific protocol. The emergence of metadata standards such as ISO 19119 plays a similarly important role in discovery as the 19115 standard. After a yearlong design, development, and testing process, the ECHO team successfully released "Reverb - The Next Generation Earth Science Discovery Tool." Reverb relies heavily on the information contained in dataset and granule metadata, such as ISO 19115, to provide a dynamic experience to users based on identified search facet values extracted from science metadata. Such an approach allows users to perform cross-dataset correlation and searches, discovering additional data that they may not previously have been aware of. In addition to data discovery, Reverb users may discover services associated with their data of interest. When services utilize supported standards and/or protocols, Reverb can facilitate the invocation of both synchronous and asynchronous data processing services. This greatly enhances a users ability to discover data of interest and accomplish their research goals. Extrapolating on the current movement towards interoperable standards and an increase in available services, data service invocation and chaining will become a natural part of data discovery. Reverb is one example of a discovery tool that provides a mechanism for transforming the earth science data discovery paradigm.

  12. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    PubMed

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  13. Why standard brain-computer interface (BCI) training protocols should be changed: an experimental study

    NASA Astrophysics Data System (ADS)

    Jeunet, Camille; Jahanpour, Emilie; Lotte, Fabien

    2016-06-01

    Objective. While promising, electroencephaloraphy based brain-computer interfaces (BCIs) are barely used due to their lack of reliability: 15% to 30% of users are unable to control a BCI. Standard training protocols may be partly responsible as they do not satisfy recommendations from psychology. Our main objective was to determine in practice to what extent standard training protocols impact users’ motor imagery based BCI (MI-BCI) control performance. Approach. We performed two experiments. The first consisted in evaluating the efficiency of a standard BCI training protocol for the acquisition of non-BCI related skills in a BCI-free context, which enabled us to rule out the possible impact of BCIs on the training outcome. Thus, participants (N = 54) were asked to perform simple motor tasks. The second experiment was aimed at measuring the correlations between motor tasks and MI-BCI performance. The ten best and ten worst performers of the first study were recruited for an MI-BCI experiment during which they had to learn to perform two MI tasks. We also assessed users’ spatial ability and pre-training μ rhythm amplitude, as both have been related to MI-BCI performance in the literature. Main results. Around 17% of the participants were unable to learn to perform the motor tasks, which is close to the BCI illiteracy rate. This suggests that standard training protocols are suboptimal for skill teaching. No correlation was found between motor tasks and MI-BCI performance. However, spatial ability played an important role in MI-BCI performance. In addition, once the spatial ability covariable had been controlled for, using an ANCOVA, it appeared that participants who faced difficulty during the first experiment improved during the second while the others did not. Significance. These studies suggest that (1) standard MI-BCI training protocols are suboptimal for skill teaching, (2) spatial ability is confirmed as impacting on MI-BCI performance, and (3) when faced with difficult pre-training, subjects seemed to explore more strategies and therefore learn better.

  14. Dealing with Daily Challenges in Dementia (Deal-id Study): An Experience Sampling Study to Assess Caregivers' Sense of Competence and Experienced Positive Affect in Daily Life.

    PubMed

    van Knippenberg, Rosalia J M; de Vugt, Marjolein E; Ponds, Rudolf W; Myin-Germeys, Inez; Verhey, Frans R J

    2017-08-01

    Positive emotions and feelings of competence seem to play an important role in the well-being of caregivers of people with dementia. Both are likely to fluctuate constantly throughout the caretaking process. Unlike standard retrospective methods, momentary assessments in daily life can provide insight into these moment-to-moment fluctuations. Therefore, in this study both retrospective and momentary assessments were used to examine the relationship between caregivers' sense of competence and their experienced positive affect (PA) in daily life. Thirty Dutch caregivers provided momentary data on PA and daily sense of competence ratings for 6 consecutive days using the experience sampling methodology. Additionally, they reported retrospectively on their sense of competence with a traditional questionnaire. A positive association was found between retrospective and daily measured sense of competence. Caregivers reported corresponding levels of sense of competence on both measures. Both daily and retrospective sense of competence were positively associated with the experienced levels of PA. However, daily sense of competence appeared to be the strongest predictor. Regarding the variability in PA, only daily sense of competence showed a significant association, with a higher daily sense of competence predicting a more stable PA pattern. This study provides support for redirecting caregiver support interventions toward enhancement of positive rather than negative experiences and focusing more on caregivers' momentary emotional experiences. Momentary assessments are a valuable addition to standard retrospective measures and provide a more comprehensive and dynamic view of caregiver functioning. Copyright © 2016 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  15. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stow, Sarah M.; Causon, Tim J.; Zheng, Xueyun

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on amore » commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.« less

  16. The hows and whys of face memory: level of construal influences the recognition of human faces

    PubMed Central

    Wyer, Natalie A.; Hollins, Timothy J.; Pahl, Sabine; Roper, Jean

    2015-01-01

    Three experiments investigated the influence of level of construal (i.e., the interpretation of actions in terms of their meaning or their details) on different stages of face memory. We employed a standard multiple-face recognition paradigm, with half of the faces inverted at test. Construal level was manipulated prior to recognition (Experiment 1), during study (Experiment 2) or both (Experiment 3). The results support a general advantage for high-level construal over low-level construal at both study and at test, and suggest that matching processing style between study and recognition has no advantage. These experiments provide additional evidence in support of a link between semantic processing (i.e., construal) and visual (i.e., face) processing. We conclude with a discussion of implications for current theories relating to both construal and face processing. PMID:26500586

  17. Testing relativity with orbiting clocks

    NASA Astrophysics Data System (ADS)

    Nissen, J. A.; Lipa, J. A.; Wang, S.; Avaloff, D.; Stricker, D. A.

    2011-02-01

    We describe the background and status of a superconducting microwave clock suitable for relativity experiments in earth orbit. The project has the capability of performing improved tests of Lorentz invariance via a Michelson-Morley type experiment, and setting new limits on nine parameters in the Standard Model Extension. If flown with a high stability atomic clock, a Kennedy-Thorndike experiment along with additional tests in general relativity could be performed.In orbit, unwanted cavity frequency variations are expected to be caused mainly by acceleration effects due to residual drag and vibration, temperature variations, and fluctuations in the energy stored in the cavity. A cavity support system has been designed to reduce acceleration effects and a high resolution thermometer has been implemented to improve temperature control.

  18. Application of step-frequency radars in medicine

    NASA Astrophysics Data System (ADS)

    Anishchenko, L.; Alekhin, M.; Tataraidze, A.; Ivashov, S.; Bugaev, Alexander S.; Soldovieri, F.

    2014-05-01

    The paper summarizes results of step-frequency radars application in medicine. Remote and non-contact control of physiological parameters with modern bioradars provides a wide range of possibilities for non-contact remote monitoring of a human psycho-emotional state and physiological condition. The paper provides information about technical characteristics of bioradars designed at Bauman Moscow State Technical University and experiments using them. Results of verification experiment showed that bioradars of BioRASCAN type may be used for simultaneous remote measurements of breathing and heart rate parameters. In addition, bioradar assisted experiments for detecting of different sleep disorders are described. Their results proved that method of bioradiolocation allows correct estimation of obstructive sleep apnea severity compared to the polysomnography method, which satisfies standard medical recommendations.

  19. Correlates of learning in introductory biomechanics.

    PubMed

    Knudson, Duane; Bauer, Jeff; Bahamonde, Rafael

    2009-04-01

    Characteristics hypothesized to be related to learning in introductory biomechanics classes were examined. Data from a 2003 national study were supplemented by additional instructor-reported data about experience, tests, laboratory hours, and average course-related expenditures. The number of credit hours of the course (r = .15) and money spent by departments on laboratory classes per year (r = -.18) were significantly and uniquely correlated with learning. Increasing credit hours from 3 to 4 with laboratory experience doubled learning. The results supported national standards for a 4-credit course and an emphasis on conceptual understanding rather than quantitative problem-solving. Researchers should seek to confirm these results as well as explore whether contact hours or the nature of laboratory learning experiences contribute to this effect.

  20. Learning to read aloud: A neural network approach using sparse distributed memory

    NASA Technical Reports Server (NTRS)

    Joglekar, Umesh Dwarkanath

    1989-01-01

    An attempt to solve a problem of text-to-phoneme mapping is described which does not appear amenable to solution by use of standard algorithmic procedures. Experiments based on a model of distributed processing are also described. This model (sparse distributed memory (SDM)) can be used in an iterative supervised learning mode to solve the problem. Additional improvements aimed at obtaining better performance are suggested.

  1. Recommendations for incorporating patient-reported outcomes into clinical comparative effectiveness research in adult oncology.

    PubMed

    Basch, Ethan; Abernethy, Amy P; Mullins, C Daniel; Reeve, Bryce B; Smith, Mary Lou; Coons, Stephen Joel; Sloan, Jeff; Wenzel, Keith; Chauhan, Cynthia; Eppard, Wayland; Frank, Elizabeth S; Lipscomb, Joseph; Raymond, Stephen A; Spencer, Merianne; Tunis, Sean

    2012-12-01

    Examining the patient's subjective experience in prospective clinical comparative effectiveness research (CER) of oncology treatments or process interventions is essential for informing decision making. Patient-reported outcome (PRO) measures are the standard tools for directly eliciting the patient experience. There are currently no widely accepted standards for developing or implementing PRO measures in CER. Recommendations for the design and implementation of PRO measures in CER were developed via a standardized process including multistakeholder interviews, a technical working group, and public comments. Key recommendations are to include assessment of patient-reported symptoms as well as health-related quality of life in all prospective clinical CER studies in adult oncology; to identify symptoms relevant to a particular study population and context based on literature review and/or qualitative and quantitative methods; to assure that PRO measures used are valid, reliable, and sensitive in a comparable population (measures particularly recommended include EORTC QLQ-C30, FACT, MDASI, PRO-CTCAE, and PROMIS); to collect PRO data electronically whenever possible; to employ methods that minimize missing patient reports and include a plan for analyzing and reporting missing PRO data; to report the proportion of responders and cumulative distribution of responses in addition to mean changes in scores; and to publish results of PRO analyses simultaneously with other clinical outcomes. Twelve core symptoms are recommended for consideration in studies in advanced or metastatic cancers. Adherence to methodologic standards for the selection, implementation, and analysis/reporting of PRO measures will lead to an understanding of the patient experience that informs better decisions by patients, providers, regulators, and payers.

  2. Improving particle filters in rainfall-runoff models: application of the resample-move step and development of the ensemble Gaussian particle filter

    NASA Astrophysics Data System (ADS)

    Plaza Guingla, D. A.; Pauwels, V. R.; De Lannoy, G. J.; Matgen, P.; Giustarini, L.; De Keyser, R.

    2012-12-01

    The objective of this work is to analyze the improvement in the performance of the particle filter by including a resample-move step or by using a modified Gaussian particle filter. Specifically, the standard particle filter structure is altered by the inclusion of the Markov chain Monte Carlo move step. The second choice adopted in this study uses the moments of an ensemble Kalman filter analysis to define the importance density function within the Gaussian particle filter structure. Both variants of the standard particle filter are used in the assimilation of densely sampled discharge records into a conceptual rainfall-runoff model. In order to quantify the obtained improvement, discharge root mean square errors are compared for different particle filters, as well as for the ensemble Kalman filter. First, a synthetic experiment is carried out. The results indicate that the performance of the standard particle filter can be improved by the inclusion of the resample-move step, but its effectiveness is limited to situations with limited particle impoverishment. The results also show that the modified Gaussian particle filter outperforms the rest of the filters. Second, a real experiment is carried out in order to validate the findings from the synthetic experiment. The addition of the resample-move step does not show a considerable improvement due to performance limitations in the standard particle filter with real data. On the other hand, when an optimal importance density function is used in the Gaussian particle filter, the results show a considerably improved performance of the particle filter.

  3. Normalization of High Dimensional Genomics Data Where the Distribution of the Altered Variables Is Skewed

    PubMed Central

    Landfors, Mattias; Philip, Philge; Rydén, Patrik; Stenberg, Per

    2011-01-01

    Genome-wide analysis of gene expression or protein binding patterns using different array or sequencing based technologies is now routinely performed to compare different populations, such as treatment and reference groups. It is often necessary to normalize the data obtained to remove technical variation introduced in the course of conducting experimental work, but standard normalization techniques are not capable of eliminating technical bias in cases where the distribution of the truly altered variables is skewed, i.e. when a large fraction of the variables are either positively or negatively affected by the treatment. However, several experiments are likely to generate such skewed distributions, including ChIP-chip experiments for the study of chromatin, gene expression experiments for the study of apoptosis, and SNP-studies of copy number variation in normal and tumour tissues. A preliminary study using spike-in array data established that the capacity of an experiment to identify altered variables and generate unbiased estimates of the fold change decreases as the fraction of altered variables and the skewness increases. We propose the following work-flow for analyzing high-dimensional experiments with regions of altered variables: (1) Pre-process raw data using one of the standard normalization techniques. (2) Investigate if the distribution of the altered variables is skewed. (3) If the distribution is not believed to be skewed, no additional normalization is needed. Otherwise, re-normalize the data using a novel HMM-assisted normalization procedure. (4) Perform downstream analysis. Here, ChIP-chip data and simulated data were used to evaluate the performance of the work-flow. It was found that skewed distributions can be detected by using the novel DSE-test (Detection of Skewed Experiments). Furthermore, applying the HMM-assisted normalization to experiments where the distribution of the truly altered variables is skewed results in considerably higher sensitivity and lower bias than can be attained using standard and invariant normalization methods. PMID:22132175

  4. Dynamic investigation of nutrient consumption and injection strategy in microbial enhanced oil recovery (MEOR) by means of large-scale experiments.

    PubMed

    Song, Zhiyong; Zhu, Weiyao; Sun, Gangzheng; Blanckaert, Koen

    2015-08-01

    Microbial enhanced oil recovery (MEOR) depends on the in situ microbial activity to release trapped oil in reservoirs. In practice, undesired consumption is a universal phenomenon but cannot be observed effectively in small-scale physical simulations due to the scale effect. The present paper investigates the dynamics of oil recovery, biomass and nutrient consumption in a series of flooding experiments in a dedicated large-scale sand-pack column. First, control experiments of nutrient transportation with and without microbial consumption were conducted, which characterized the nutrient loss during transportation. Then, a standard microbial flooding experiment was performed recovering additional oil (4.9 % Original Oil in Place, OOIP), during which microbial activity mostly occurred upstream, where oil saturation declined earlier and steeper than downstream in the column. Subsequently, more oil remained downstream due to nutrient shortage. Finally, further research was conducted to enhance the ultimate recovery by optimizing the injection strategy. An extra 3.5 % OOIP was recovered when the nutrients were injected in the middle of the column, and another additional 11.9 % OOIP were recovered by altering the timing of nutrient injection.

  5. A differentiable reformulation for E-optimal design of experiments in nonlinear dynamic biosystems.

    PubMed

    Telen, Dries; Van Riet, Nick; Logist, Flip; Van Impe, Jan

    2015-06-01

    Informative experiments are highly valuable for estimating parameters in nonlinear dynamic bioprocesses. Techniques for optimal experiment design ensure the systematic design of such informative experiments. The E-criterion which can be used as objective function in optimal experiment design requires the maximization of the smallest eigenvalue of the Fisher information matrix. However, one problem with the minimal eigenvalue function is that it can be nondifferentiable. In addition, no closed form expression exists for the computation of eigenvalues of a matrix larger than a 4 by 4 one. As eigenvalues are normally computed with iterative methods, state-of-the-art optimal control solvers are not able to exploit automatic differentiation to compute the derivatives with respect to the decision variables. In the current paper a reformulation strategy from the field of convex optimization is suggested to circumvent these difficulties. This reformulation requires the inclusion of a matrix inequality constraint involving positive semidefiniteness. In this paper, this positive semidefiniteness constraint is imposed via Sylverster's criterion. As a result the maximization of the minimum eigenvalue function can be formulated in standard optimal control solvers through the addition of nonlinear constraints. The presented methodology is successfully illustrated with a case study from the field of predictive microbiology. Copyright © 2015. Published by Elsevier Inc.

  6. Display size effects in visual search: analyses of reaction time distributions as mixtures.

    PubMed

    Reynolds, Ann; Miller, Jeff

    2009-05-01

    In a reanalysis of data from Cousineau and Shiffrin (2004) and two new visual search experiments, we used a likelihood ratio test to examine the full distributions of reaction time (RT) for evidence that the display size effect is a mixture-type effect that occurs on only a proportion of trials, leaving RT in the remaining trials unaffected, as is predicted by serial self-terminating search models. Experiment 1 was a reanalysis of Cousineau and Shiffrin's data, for which a mixture effect had previously been established by a bimodal distribution of RTs, and the results confirmed that the likelihood ratio test could also detect this mixture. Experiment 2 applied the likelihood ratio test within a more standard visual search task with a relatively easy target/distractor discrimination, and Experiment 3 applied it within a target identification search task within the same types of stimuli. Neither of these experiments provided any evidence for the mixture-type display size effect predicted by serial self-terminating search models. Overall, these results suggest that serial self-terminating search models may generally be applicable only with relatively difficult target/distractor discriminations, and then only for some participants. In addition, they further illustrate the utility of analysing full RT distributions in addition to mean RT.

  7. 21 CFR 170.10 - Food additives in standardized foods.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Food additives in standardized foods. 170.10... (CONTINUED) FOOD ADDITIVES General Provisions § 170.10 Food additives in standardized foods. (a) The... inclusion of a food additive in such definition and standard of identity, the provisions of the regulations...

  8. Advancing non-directive pregnancy options counseling skills: A pilot Study on the use of blended learning with an online module and simulation.

    PubMed

    Lupi, Carla; Ward-Peterson, Melissa; Chang, Winnie

    2016-10-01

    Limitations on didactic time pose barriers to teaching non-directive pregnancy options counseling. This study set out to explore the use of an online module to support trainee performance in a pregnancy options counseling standardized-patient exercise implemented among third-year medical students, and to examine the effect of clinical experience on student performance. An online module was developed. A convenience sample of forty-six student performances in a family medicine clerkship participated in a standardized patient exercise. Trained faculty rated performances. Students completed a self-assessment and provided feedback on the online module. Chi-square and Mann-Whitney-U tests were used to analyze data. Three coders qualitatively examined narrative student comments. Thirty-four students passed, 11 achieved a minimal pass, and one failed. The mean global rating from faculty was 2.8 (pass). Students with prior clinical experience significantly outperformed those without on the global rating scale with mean scores of 3.1 compared to 2.7, respectively (p=.044). All students agreed that the online module helped prepare them for the exercise. Qualitative analysis of students' feedback on the module revealed strengths in content and pedagogy. In their self-assessments, all but two students referred to content explicitly conveyed in the module. All students agreed that an online module supported their performance of non-directive pregnancy options counseling skills. Prior clinical experience was associated with improved performance. This module, along with the simulated exercise, can be implemented as a blended learning exercise without additional faculty teaching effort in standardized patient resource centers. Students agreed that an online module facilitates simulated performance of non-directive pregnancy options counseling skills. Future work should compare the impact of this approach to others, and explore the additional training needed to maintain and build on initial learning. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Precision Tests of the Electroweak Interaction using Trapped Atoms and Ions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Melconian, Daniel George

    The objective of the proposed research is to study fundamental aspects of the electroweak interaction via precision measurements in beta decay to test our current understanding of fundamental particles and forces as contained in the so-called "Standard Model" of particle physics. By comparing elegant experiments to rigorous theoretical predictions, we will either confirm the Standard Model to a higher degree and rule out models which seek to extend it, or find evidence of new physics and help guide theorists in developing the New Standard Model. The use of ion and neutral atom traps at radioactive ion beam facilities has openedmore » up a new vista in precision low-energy nuclear physics experiments. Traps provide an ideal source of decaying atoms: they can be extremely cold (~1 mK); they are compact (~1 mm^3); and perhaps most importantly, the daughter particles escape with negligible distortions to their momenta in a scattering-free, open environment. The project is taking advantage of these technologies and applying them to precision beta-decay studies at radioactive beam facilities. The program consists of two complementary efforts: 1) Ion traps are an extremely versatile tool for purifying, cooling and bunching low-energy beams of short-lived nuclei. A large-bore (210~mm) superconducting 7-Tesla solenoid is at the heart of a Penning trap system for which there is a dedicated beamline at T-REX, the upgraded radioactive beam facility at the Cyclotron Institute, Texas A&M University. In addition to providing a general-purpose decay station, the flagship program for this system is measuring the ft-values and beta-neutrino correlation parameters from isospin T=2 superallowed beta-delayed proton decays, complimenting and expanding the already strong program in fundamental interactions at the Institute. 2) A magneto-optical trap is being used at the TRIUMF Neutral Atom Trap facility to observe the (un)polarized angular distribution parameters of isotopes of potassium. We are able to highly polarize laser-cooled atoms and observe their decay with unprecedented precision. The correlation of the daughter beta particle with the initial nuclear spin as well as other correlations are sensitive to physics beyond the Standard Model. Both of these cutting-edge and exciting research efforts will test our understanding of the fundamental symmetries underlying our current theory of electroweak interactions. Complementary to high-energy collider experiments, these low-energy nuclear physics "table-top" experiments will search for new particles and interactions which are not already described by the Standard Model of particle physics. The value of this research is recognized to be cross-disciplinary, exciting and potentially revolutionary in our understanding of nature's fundamental interactions. Accordingly, it has been endorsed by the recent (2007) Nuclear Science Advisory Committee's Long Range Plan as part of their recommendation for a "New Standard Model Initiative." In addition to the near-term benefits of scholarly publications and visibility through description of this work at international conferences, an important benefit of this research program is the training of new, young and enthusiastic nuclear physicists. Participants in this demanding and rewarding field develop a very strong background in physics with experience in a range of its subfields since we use atomic techniques and apply them to a nuclear physics experiment which in the end tests the theories of high-energy physics.« less

  10. Comparison of patients' assessments of the quality of stroke care with audit findings.

    PubMed

    Howell, Esther; Graham, Chris; Hoffman, A; Lowe, D; McKevitt, Christopher; Reeves, Rachel; Rudd, A G

    2007-12-01

    To determine the extent of correlation between stroke patients' experiences of hospital care with the quality of services assessed in a national audit. Patients' assessments of their care derived from survey data were linked to data obtained in the National Sentinel Stroke Audit 2004 for 670 patients in 51 English NHS trusts. A measure of patients' experience of hospital stroke care was derived by summing responses to 31 survey items and grouping these into three broad concept domains: quality of care; information; and relationships with staff. Audit data were extracted from hospital admissions data and management information to assess the organisation of services, and obtained retrospectively from patient records to evaluate the delivery of care. Patient survey responses were compared with audit measures of organisation of care and compliance with clinical process standards. Patient experience scores were positively correlated with clinicians' assessment of the organisational quality of stroke care, but were largely unrelated to clinical process standards. Responses to individual questions regarding communication about diagnosis revealed a discrepancy between clinicians' and patients' reports. Better organised stroke care is associated with more positive patient experiences. Examining areas of disparity between patients' and clinicians' reports is important for understanding the complex nature of healthcare and for identifying areas for quality improvement. Future evaluations of the quality of stroke services should include a validated patient experience survey in addition to audit of clinical records.

  11. Approaches and considerations for the assessment of immunotoxicity for environmental chemicals: a workshop summary.

    PubMed

    Boverhof, Darrell R; Ladics, Greg; Luebke, Bob; Botham, Jane; Corsini, Emanuela; Evans, Ellen; Germolec, Dori; Holsapple, Michael; Loveless, Scott E; Lu, Haitian; van der Laan, Jan Willem; White, Kimber L; Yang, Yung

    2014-02-01

    As experience is gained with toxicology testing and as new assays and technologies are developed, it is critical for stakeholders to discuss opportunities to advance our overall testing strategies. To facilitate these discussions, a workshop on practices for assessing immunotoxicity for environmental chemicals was held with the goal of sharing perspectives on immunotoxicity testing strategies and experiences, developmental immunotoxicity (DIT), and integrated and alternative approaches to immunotoxicity testing. Experiences across the chemical and pharmaceutical industries suggested that standard toxicity studies, combined with triggered-based testing approaches, represent an effective and efficient approach to evaluate immunotoxic potential. Additionally, discussions on study design, critical windows, and new guideline approaches and experiences identified important factors to consider before initiating DIT evaluations including assay choice and timing and the impact of existing adult data. Participants agreed that integrating endpoints into standard repeat-dose studies should be considered for fulfilling any immunotoxicity testing requirements, while also maximizing information and reducing animal use. Participants also acknowledged that in vitro evaluation of immunosuppression is complex and may require the use of multiple assays that are still being developed. These workshop discussions should contribute to developing an effective but more resource and animal efficient approach for evaluating chemical immunotoxicity. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. [Peroperative peritoneal lavage and intra-abdominal instillation of antibiotics in an experiment].

    PubMed

    Batalík, B; Mydlo, J

    1991-03-01

    The authors present the results of an experiment on dogs where lethal diffuse peritonitis was induced in the standard way and was treated only by peroperative peritoneal lavage during reoperation within 24 hours. In the first group (n = 10) this method alone reduced the mortality despite the adverse prognosis to 70%, after addition of an effective antibiotic and metronidazole into the last lot of the lavage solution in the second equally sized group to 10%. The results prove a marked therapeutic asset of this method which as part of comprehensive treatment of peritonitis improves substantially the final effect also under clinical conditions.

  13. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review

    PubMed Central

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38–45 and 62–55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking. PMID:26131451

  14. One-Step Nucleic Acid Amplification in Breast Cancer Sentinel Lymph Node: A Single Institutional Experience and a Short Review.

    PubMed

    Brambilla, Tatiana; Fiamengo, Barbara; Tinterri, Corrado; Testori, Alberto; Grassi, Massimo Maria; Sciarra, Amedeo; Abbate, Tommaso; Gatzemeier, Wolfgang; Roncalli, Massimo; Di Tommaso, Luca

    2015-01-01

    Sentinel lymph node (SLN) examination is a standard in breast cancer patients, with several methods employed along its 20 years history, the last one represented by one-step nucleic acid amplification (OSNA). The latter is a intra-operative molecular assay searching for CK19 mRNA as a surrogate of metastatic cells. Our 3 years experience with OSNA (1122 patients) showed results overlapping those recorded in the same institution with a morphological evaluation (930 patients) of SLN. In detail, the data of OSNA were almost identical to those observed with standard post-operative procedure in terms of patients with positive SLN (30%) and micrometastatic/macrometastatic involvement of SLN (respectively, 38-45 and 62-55%). By contrast, when OSNA was compared to the standard intraoperatory procedure, it was superior in terms of accuracy, prompting the use of this molecular assay as a very valid, and reproducible for intra-operative evaluation of SLN. Further possibilities prompting the use of OSNA range from adhesion to quality control programs, saving of medical time, ability to predict, during surgery, additional nodal metastasis, and molecular bio-banking.

  15. Education in Biomedical and Health Informatics in the Web 3.0 Era: Standards for data, curricula, and activities. Contribution of the IMIA Working Group on Health and Medical Informatics Education.

    PubMed

    Otero, P; Hersh, W

    2011-01-01

    Web 3.0 is transforming the World Wide Web by allowing knowledge and reasoning to be gleaned from its content. Describe a new scenario in education and training known as "Education 3.0" that can help in the promotion of learning in health informatics in a collaborative way. Review of the current standards available for curricula and learning activities in in Biomedical and Health Informatics (BMHI) for a Web 3.0 scenario. A new scenario known as "Education 3.0" can provide open educational resources created and reused throughout different institutions and improved by means of an international collaborative knowledge powered by the use of E-learning. Currently there are standards that could be used in identifying and deliver content in education in BMHI in the semantic web era such as Resource Description Format (RDF), Web Ontology Language (OWL) and Sharable Content Object Reference Model (SCORM). In addition, there are other standards to support healthcare education and training. There are few experiences in the use of standards in e-learning in BMHI published in the literature. Web 3.0 can propose new approaches to building the BMHI workforce so there is a need to build tools as knowledge infrastructure to leverage it. The usefulness of standards in the content and competencies of training programs in BMHI needs more experience and research so as to promote the interoperability and sharing of resources in this growing discipline.

  16. CT and MR Protocol Standardization Across a Large Health System: Providing a Consistent Radiologist, Patient, and Referring Provider Experience.

    PubMed

    Sachs, Peter B; Hunt, Kelly; Mansoubi, Fabien; Borgstede, James

    2017-02-01

    Building and maintaining a comprehensive yet simple set of standardized protocols for a cross-sectional image can be a daunting task. A single department may have difficulty preventing "protocol creep," which almost inevitably occurs when an organized "playbook" of protocols does not exist and individual radiologists and technologists alter protocols at will and on a case-by-case basis. When multiple departments or groups function in a large health system, the lack of uniformity of protocols can increase exponentially. In 2012, the University of Colorado Hospital formed a large health system (UCHealth) and became a 5-hospital provider network. CT and MR imaging studies are conducted at multiple locations by different radiology groups. To facilitate consistency in ordering, acquisition, and appearance of a given study, regardless of location, we minimized the number of protocols across all scanners and sites of practice with a clinical indication-driven protocol selection and standardization process. Here we review the steps utilized to perform this process improvement task and insure its stability over time. Actions included creation of a standardized protocol template, which allowed for changes in electronic storage and management of protocols, designing a change request form, and formation of a governance structure. We utilized rapid improvement events (1 day for CT, 2 days for MR) and reduced 248 CT protocols into 97 standardized protocols and 168 MR protocols to 66. Additional steps are underway to further standardize output and reporting of imaging interpretation. This will result in an improved, consistent radiologist, patient, and provider experience across the system.

  17. Higgs Boson Searches at Hadron Colliders (1/4)

    ScienceCinema

    Jakobs, Karl

    2018-05-21

    In these Academic Training lectures, the phenomenology of Higgs bosons and search strategies at hadron colliders are discussed. After a brief introduction on Higgs bosons in the Standard Model and a discussion of present direct and indirect constraints on its mass the status of the theoretical cross section calculations for Higgs boson production at hadron colliders is reviewed. In the following lectures important experimental issues relevant for Higgs boson searches (trigger, measurements of leptons, jets and missing transverse energy) are presented. This is followed by a detailed discussion of the discovery potential for the Standard Model Higgs boson for both the Tevatron and the LHC experiments. In addition, various scenarios beyond the Standard Model, primarily the MSSM, are considered. Finally, the potential and strategies to measured Higgs boson parameters and the investigation of alternative symmetry breaking scenarios are addressed.

  18. A highly parallel multigrid-like method for the solution of the Euler equations

    NASA Technical Reports Server (NTRS)

    Tuminaro, Ray S.

    1989-01-01

    We consider a highly parallel multigrid-like method for the solution of the two dimensional steady Euler equations. The new method, introduced as filtering multigrid, is similar to a standard multigrid scheme in that convergence on the finest grid is accelerated by iterations on coarser grids. In the filtering method, however, additional fine grid subproblems are processed concurrently with coarse grid computations to further accelerate convergence. These additional problems are obtained by splitting the residual into a smooth and an oscillatory component. The smooth component is then used to form a coarse grid problem (similar to standard multigrid) while the oscillatory component is used for a fine grid subproblem. The primary advantage in the filtering approach is that fewer iterations are required and that most of the additional work per iteration can be performed in parallel with the standard coarse grid computations. We generalize the filtering algorithm to a version suitable for nonlinear problems. We emphasize that this generalization is conceptually straight-forward and relatively easy to implement. In particular, no explicit linearization (e.g., formation of Jacobians) needs to be performed (similar to the FAS multigrid approach). We illustrate the nonlinear version by applying it to the Euler equations, and presenting numerical results. Finally, a performance evaluation is made based on execution time models and convergence information obtained from numerical experiments.

  19. Aging and visual length discrimination: sequential dependencies, biases, and the effects of multiple implicit standards.

    PubMed

    Norman, J Farley; Cheeseman, Jacob R; Baxter, Michael W; Thomason, Kelsey E; Adkins, Olivia C; Rogers, Connor E

    2014-05-01

    Younger (20-25 years of age) and older (61-79 years) adults were evaluated for their ability to visually discriminate length. Almost all experiments that have utilized the method of single stimuli to date have required participants to judge test stimuli relative to a single implicit standard (for a rare exception, see Morgan, On the scaling of size judgements by orientational cues, Vision Research, 1992, 32, 1433-1445). In the current experiments, we not only asked participants to judge lengths relative to a single implicit standard, but they also compared test stimuli to two different implicit standards within the same blocks of trials. We analyzed our participants' judgments to evaluate whether significant sequential dependencies occurred. We found that while individual younger and older adults possessed similar length difference thresholds and exhibited similar overall biases, the judgments of older adults within individual blocks of trials were more strongly biased (than younger adults) by preceding responses (i.e., their judgments on any given trial were more strongly affected by responses to previously viewed stimuli). In addition, the judgments of both younger and older adults were more strongly biased by preceding responses in the blocks of trials with multiple implicit standards. Overall, our results are consistent with the operation of the tracking mechanism described by Criterion-setting theory (Lages and Treisman, Spatial frequency discrimination: Visual long-term memory or criterion setting? Vision Research, 1998, 38, 557-572). Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. 21 CFR 70.10 - Color additives in standardized foods and new drugs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Color additives in standardized foods and new... SERVICES GENERAL COLOR ADDITIVES General Provisions § 70.10 Color additives in standardized foods and new... proposes the inclusion of a color additive in the standardized food, the provisions of the regulations in...

  1. 21 CFR 70.10 - Color additives in standardized foods and new drugs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Color additives in standardized foods and new... SERVICES GENERAL COLOR ADDITIVES General Provisions § 70.10 Color additives in standardized foods and new... proposes the inclusion of a color additive in the standardized food, the provisions of the regulations in...

  2. 21 CFR 70.10 - Color additives in standardized foods and new drugs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Color additives in standardized foods and new... SERVICES GENERAL COLOR ADDITIVES General Provisions § 70.10 Color additives in standardized foods and new... proposes the inclusion of a color additive in the standardized food, the provisions of the regulations in...

  3. 21 CFR 70.10 - Color additives in standardized foods and new drugs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Color additives in standardized foods and new... SERVICES GENERAL COLOR ADDITIVES General Provisions § 70.10 Color additives in standardized foods and new... proposes the inclusion of a color additive in the standardized food, the provisions of the regulations in...

  4. 21 CFR 70.10 - Color additives in standardized foods and new drugs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Color additives in standardized foods and new... SERVICES GENERAL COLOR ADDITIVES General Provisions § 70.10 Color additives in standardized foods and new... proposes the inclusion of a color additive in the standardized food, the provisions of the regulations in...

  5. Satellite classification and segmentation using non-additive entropy

    NASA Astrophysics Data System (ADS)

    Assirati, Lucas; Souto Martinez, Alexandre; Martinez Bruno, Odemir

    2014-03-01

    Here we compare the Boltzmann-Gibbs-Shannon (standard) with the Tsallis entropy on the pattern recognition and segmentation of colored images obtained by satellites, via "Google Earth". By segmentation we mean particionate an image to locate regions of interest. Here, we discriminate and define an image partition classes according to a training basis. This training basis consists of three pattern classes: aquatic, urban and vegetation regions. Our numerical experiments demonstrate that the Tsallis entropy, used as a feature vector composed of distinct entropic indexes q outperforms the standard entropy. There are several applications of our proposed methodology, once satellite images can be used to monitor migration form rural to urban regions, agricultural activities, oil spreading on the ocean etc.

  6. Diffeomorphic demons: efficient non-parametric image registration.

    PubMed

    Vercauteren, Tom; Pennec, Xavier; Perchant, Aymeric; Ayache, Nicholas

    2009-03-01

    We propose an efficient non-parametric diffeomorphic image registration algorithm based on Thirion's demons algorithm. In the first part of this paper, we show that Thirion's demons algorithm can be seen as an optimization procedure on the entire space of displacement fields. We provide strong theoretical roots to the different variants of Thirion's demons algorithm. This analysis predicts a theoretical advantage for the symmetric forces variant of the demons algorithm. We show on controlled experiments that this advantage is confirmed in practice and yields a faster convergence. In the second part of this paper, we adapt the optimization procedure underlying the demons algorithm to a space of diffeomorphic transformations. In contrast to many diffeomorphic registration algorithms, our solution is computationally efficient since in practice it only replaces an addition of displacement fields by a few compositions. Our experiments show that in addition to being diffeomorphic, our algorithm provides results that are similar to the ones from the demons algorithm but with transformations that are much smoother and closer to the gold standard, available in controlled experiments, in terms of Jacobians.

  7. Evaluation and optimization of hepatocyte culture media factors by design of experiments (DoE) methodology

    PubMed Central

    Dong, Jia; Lübberstedt, Marc; Urbaniak, Thomas; Nüssler, Andreas K.N.; Knobeloch, Daniel; Gerlach, Jörg C.; Zeilinger, Katrin

    2008-01-01

    Optimization of cell culture media based on statistical experimental design methodology is a widely used approach for improving cultivation conditions. We applied this methodology to refine the composition of an established culture medium for growth of a human hepatoma cell line, C3A. A selection of growth factors and nutrient supplements were systematically screened according to standard design of experiments (DoE) procedures. The results of the screening indicated that the medium additives hepatocyte growth factor, oncostatin M, and fibroblast growth factor 4 significantly influenced the metabolic activities of the C3A cell line. Surface response methodology revealed that the optimum levels for these factors were 30 ng/ml for hepatocyte growth factor and 35 ng/ml for oncostatin M. Additional experiments on primary human hepatocyte cultures showed high variance in metabolic activities between cells from different individuals, making determination of optimal levels of factors more difficult. Still, it was possible to conclude that hepatocyte growth factor, epidermal growth factor, and oncostatin M had decisive effects on the metabolic functions of primary human hepatocytes. PMID:19003182

  8. Evaluation and optimization of hepatocyte culture media factors by design of experiments (DoE) methodology.

    PubMed

    Dong, Jia; Mandenius, Carl-Fredrik; Lübberstedt, Marc; Urbaniak, Thomas; Nüssler, Andreas K N; Knobeloch, Daniel; Gerlach, Jörg C; Zeilinger, Katrin

    2008-07-01

    Optimization of cell culture media based on statistical experimental design methodology is a widely used approach for improving cultivation conditions. We applied this methodology to refine the composition of an established culture medium for growth of a human hepatoma cell line, C3A. A selection of growth factors and nutrient supplements were systematically screened according to standard design of experiments (DoE) procedures. The results of the screening indicated that the medium additives hepatocyte growth factor, oncostatin M, and fibroblast growth factor 4 significantly influenced the metabolic activities of the C3A cell line. Surface response methodology revealed that the optimum levels for these factors were 30 ng/ml for hepatocyte growth factor and 35 ng/ml for oncostatin M. Additional experiments on primary human hepatocyte cultures showed high variance in metabolic activities between cells from different individuals, making determination of optimal levels of factors more difficult. Still, it was possible to conclude that hepatocyte growth factor, epidermal growth factor, and oncostatin M had decisive effects on the metabolic functions of primary human hepatocytes.

  9. The comprehension skills of children learning English as an additional language.

    PubMed

    Burgoyne, K; Kelly, J M; Whiteley, H E; Spooner, A

    2009-12-01

    Data from national test results suggests that children who are learning English as an additional language (EAL) experience relatively lower levels of educational attainment in comparison to their monolingual, English-speaking peers. The relative underachievement of children who are learning EAL demands that the literacy needs of this group are identified. To this end, this study aimed to explore the reading- and comprehension-related skills of a group of EAL learners. Data are reported from 92 Year 3 pupils, of whom 46 children are learning EAL. Children completed standardized measures of reading accuracy and comprehension, listening comprehension, and receptive and expressive vocabulary. Results indicate that many EAL learners experience difficulties in understanding written and spoken text. These comprehension difficulties are not related to decoding problems but are related to significantly lower levels of vocabulary knowledge experienced by this group. Many EAL learners experience significantly lower levels of English vocabulary knowledge which has a significant impact on their ability to understand written and spoken text. Greater emphasis on language development is therefore needed in the school curriculum to attempt to address the limited language skills of children learning EAL.

  10. Results of FM-TV threshold reduction investigation for the ATS F trust experiment

    NASA Technical Reports Server (NTRS)

    Brown, J. P.

    1972-01-01

    An investigation of threshold effects in FM TV was initiated to determine if any simple, low cost techniques were available which can reduce the subjective video threshold, applicable to low cost community TV reception via satellite. Two methods of eliminating these effects were examined: the use of standard video pre-emphasis, and the use of an additional circuit to blank the picture tube during the retrace period.

  11. Revision of the NIST Standard for (223)Ra: New Measurements and Review of 2008 Data.

    PubMed

    Zimmerman, B E; Bergeron, D E; Cessna, J T; Fitzgerald, R; Pibida, L

    2015-01-01

    After discovering a discrepancy in the transfer standard currently being disseminated by the National Institute of Standards and Technology (NIST), we have performed a new primary standardization of the alpha-emitter (223)Ra using Live-timed Anticoincidence Counting (LTAC) and the Triple-to-Double Coincidence Ratio Method (TDCR). Additional confirmatory measurements were made with the CIEMAT-NIST efficiency tracing method (CNET) of liquid scintillation counting, integral γ-ray counting using a NaI(Tl) well counter, and several High Purity Germanium (HPGe) detectors in an attempt to understand the origin of the discrepancy and to provide a correction. The results indicate that a -9.5 % difference exists between activity values obtained using the former transfer standard relative to the new primary standardization. During one of the experiments, a 2 % difference in activity was observed between dilutions of the (223)Ra master solution prepared using the composition used in the original standardization and those prepared using 1 mol·L(-1) HCl. This effect appeared to be dependent on the number of dilutions or the total dilution factor to the master solution, but the magnitude was not reproducible. A new calibration factor ("K-value") has been determined for the NIST Secondary Standard Ionization Chamber (IC "A"), thereby correcting the discrepancy between the primary and secondary standards.

  12. Web-based analysis and publication of flow cytometry experiments.

    PubMed

    Kotecha, Nikesh; Krutzik, Peter O; Irish, Jonathan M

    2010-07-01

    Cytobank is a Web-based application for storage, analysis, and sharing of flow cytometry experiments. Researchers use a Web browser to log in and use a wide range of tools developed for basic and advanced flow cytometry. In addition to providing access to standard cytometry tools from any computer, Cytobank creates a platform and community for developing new analysis and publication tools. Figure layouts created on Cytobank are designed to allow transparent access to the underlying experiment annotation and data processing steps. Since all flow cytometry files and analysis data are stored on a central server, experiments and figures can be viewed or edited by anyone with the proper permission, from any computer with Internet access. Once a primary researcher has performed the initial analysis of the data, collaborators can engage in experiment analysis and make their own figure layouts using the gated, compensated experiment files. Cytobank is available to the scientific community at http://www.cytobank.org. (c) 2010 by John Wiley & Sons, Inc.

  13. Web-Based Analysis and Publication of Flow Cytometry Experiments

    PubMed Central

    Kotecha, Nikesh; Krutzik, Peter O.; Irish, Jonathan M.

    2014-01-01

    Cytobank is a web-based application for storage, analysis, and sharing of flow cytometry experiments. Researchers use a web browser to log in and use a wide range of tools developed for basic and advanced flow cytometry. In addition to providing access to standard cytometry tools from any computer, Cytobank creates a platform and community for developing new analysis and publication tools. Figure layouts created on Cytobank are designed to allow transparent access to the underlying experiment annotation and data processing steps. Since all flow cytometry files and analysis data are stored on a central server, experiments and figures can be viewed or edited by anyone with the proper permissions from any computer with Internet access. Once a primary researcher has performed the initial analysis of the data, collaborators can engage in experiment analysis and make their own figure layouts using the gated, compensated experiment files. Cytobank is available to the scientific community at www.cytobank.org PMID:20578106

  14. Photo screening around the world: Lions Club International Foundation experience.

    PubMed

    Donahue, Sean P; Lorenz, Sylvia; Johnson, Tammy

    2008-01-01

    To describe the use of photoscreening for preschool vision screening in several diverse locations throughout the world. The MTI photo screener was used to screen pre-verbal children; photographs were interpreted using standard criteria. The Tennessee vision screening program remains successful, screening over 200,000 children during the past 8 years. Similar programs modeled across the United States have screened an additional 500,000 children. A pilot demonstration project in Hong Kong, Beijing, and Brazil screened over 5000 additional children with good success and appropriately low referral rates. Photoscreening can be an appropriate technique for widespread vision screening of preschool children throughout the world.

  15. Overcoming psychosocial and developmental barriers to blood and marrow transplantation (BMT) in an adolescent/young adult (AYA) transgender patient with chronic myelogenous leukemia.

    PubMed

    Khazal, Sajad; Abdel-Azim, Hisham; Kapoor, Neena; Mahadeo, Kris M

    2014-11-01

    Adolescents/young adults (AYAs) afflicted with cancer face unique barriers to potentially standard curative therapies, such as blood and marrow transplantation (BMT). Transgender AYAs face additional barriers and there is a dearth of published literature regarding their oncology-related experience. We present the case of an AYA male-to-female (MTF) transgender patient on cross-sex hormone therapy, with a history of Chronic Myelogenous Leukemia (CML) and significant psychosocial barriers, which initially served as a barrier to BMT at two different centers; we modified our standard consent and education process and was able to successfully proceed with BMT and subsequently cure her CML. Despite unique challenges, AYA and transgender patients with significant psychosocial barriers may achieve successful outcomes with BMT. Research is needed regarding guidelines for cross-sex hormone therapy administration for patients undergoing BMT and other issues, which may be unique to the transgender experience.

  16. Identifying WIMP dark matter from particle and astroparticle data

    NASA Astrophysics Data System (ADS)

    Bertone, Gianfranco; Bozorgnia, Nassim; Kim, Jong Soo; Liem, Sebastian; McCabe, Christopher; Otten, Sydney; Ruiz de Austri, Roberto

    2018-03-01

    One of the most promising strategies to identify the nature of dark matter consists in the search for new particles at accelerators and with so-called direct detection experiments. Working within the framework of simplified models, and making use of machine learning tools to speed up statistical inference, we address the question of what we can learn about dark matter from a detection at the LHC and a forthcoming direct detection experiment. We show that with a combination of accelerator and direct detection data, it is possible to identify newly discovered particles as dark matter, by reconstructing their relic density assuming they are weakly interacting massive particles (WIMPs) thermally produced in the early Universe, and demonstrating that it is consistent with the measured dark matter abundance. An inconsistency between these two quantities would instead point either towards additional physics in the dark sector, or towards a non-standard cosmology, with a thermal history substantially different from that of the standard cosmological model.

  17. 78 FR 18372 - TUV Rheinland of North America, Inc.; Expansion of Recognition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... covers the addition of a new site and the use one additional test standard. OSHA's current scope of..., and one additional test standard. In response to OSHA's requests for clarification, TUV amended its... NRTL Program staff determined that the additional test standard is an ``appropriate test standard...

  18. Knowledge of attention deficit hyperactivity disorder and its associated factors among teachers in 3 large primary schools in Phra Nakorn Sri Ayutthaya Province, Thailand.

    PubMed

    Muanprasart, Pongchanok; Traivaree, Chanchai; Arunyanart, Wirongrong; Teeranate, Chakriya

    2014-02-01

    Though attention deficit, hyperactivity disorder ADHD is a common problem in childhood. Thai teachers' knowledge regarding the disease has never been assessed. To identify knowledge of Thai teachers regardingADHD and its influencingfactors. Cross-sectional study was operated in three primary schools in Ayutthaya, Thailand. Standardized questionnaires comprised ofdemographic data, ADHD experiences and the Knowledge of Attention Deficit Disorder Scale, KADDS, were distributed to participating teachers. Results were reported using frequency, percent, mean, and standard deviation. Association between demographic and ADHD experiences and the KADDS score was identified by logistic regression analysis. Lack ofknowledge of ADHD among teachers was apparent. Only 19.4% of them passed the total scale of KADDS. Teachers under 31-years-old were more likely to pass general information and signs, symptoms & diagnosis subscales and total scale. In addition, familiarity with ADHD patients was associated with passing scores of general information subscale and total scale. Despite public awareness of ADHD, Thai teachers lacked knowledge concerning the disease. Young teachers were more acquainted with ADHD. Direct experience with ADHD patient might help teachers develop their knowledge on ADHD.

  19. European dry cooling tower operating experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DeSteese, J.G.; Simhan, K.

    1976-03-01

    Interviews were held with representatives of major plants and equipment manufacturers to obtain current information on operating experience with dry cooling towers in Europe. The report documents the objectives, background, and organizational details of the study, and presents an itemized account of contacts made to obtain information. Plant selection was based on a merit index involving thermal capacity and length of service. A questionnaire was used to organize operational data, when available, into nine major categories of experience. Information was also solicited concerning the use of codes and standards to ensure the achievement of cooling tower performance. Several plant operatorsmore » provided finned-tube samples for metallographic analysis. Additionally, information on both operating experience and developing technology was supplied by European technical societies and research establishments. Information obtained from these contacts provides an updated and representative sample of European experience with dry cooling towers, which supplements some of the detailed reviews already available in the literature. In addition, the study presents categorized operating experience with installations which have not been reviewed so extensively, but nevertheless, have significant operational histories when ranked by the merit index. The contacts and interviews reported in the survey occurred between late March and October 1975. The study was motivated by the expressed interest of U.S. utility industry representatives who expect European experience to provide a basis of confidence that dry cooling is a reliable technology, applicable when necessary, to U.S. operating requirements.« less

  20. Neutrino oscillations and Non-Standard Interactions

    NASA Astrophysics Data System (ADS)

    Farzan, Yasaman; Tórtola, Mariam

    2018-02-01

    Current neutrino experiments are measuring the neutrino mixing parameters with an unprecedented accuracy. The upcoming generation of neutrino experiments will be sensitive to subdominant oscillation effects that can give information on the yet-unknown neutrino parameters: the Dirac CP-violating phase, the mass ordering and the octant of θ_{23}. Determining the exact values of neutrino mass and mixing parameters is crucial to test neutrino models and flavor symmetries designed to predict these neutrino parameters. In the first part of this review, we summarize the current status of the neutrino oscillation parameter determination. We consider the most recent data from all solar experiments and the atmospheric data from Super-Kamiokande, IceCube and ANTARES. We also implement the data from the reactor neutrino experiments KamLAND, Daya Bay, RENO and Double Chooz as well as the long baseline neutrino data from MINOS, T2K and NOvA. If in addition to the standard interactions, neutrinos have subdominant yet-unknown Non-Standard Interactions (NSI) with matter fields, extracting the values of these parameters will suffer from new degeneracies and ambiguities. We review such effects and formulate the conditions on the NSI parameters under which the precision measurement of neutrino oscillation parameters can be distorted. Like standard weak interactions, the non-standard interaction can be categorized into two groups: Charged Current (CC) NSI and Neutral Current (NC) NSI. Our focus will be mainly on neutral current NSI because it is possible to build a class of models that give rise to sizeable NC NSI with discernible effects on neutrino oscillation. These models are based on new U(1) gauge symmetry with a gauge boson of mass ≲ 10 MeV. The UV complete model should be of course electroweak invariant which in general implies that along with neutrinos, charged fermions also acquire new interactions on which there are strong bounds. We enumerate the bounds that already exist on the electroweak symmetric models and demonstrate that it is possible to build viable models avoiding all these bounds. In the end, we review methods to test these models and suggest approaches to break the degeneracies in deriving neutrino mass parameters caused by NSI.

  1. DATA MANAGEMENT SYSTEM FOR MOBILE SATELLITE PROPAGATION DATA

    NASA Technical Reports Server (NTRS)

    Kantak, A. V.

    1994-01-01

    The "Data Management System for Mobile Satellite Propogation" package is a collection of FORTRAN programs and UNIX shell scripts designed to handle the huge amounts of data resulting from Mobile Satellite propogation experiments. These experiments are designed to assist in defining channels for mobile satellite systems. By understanding multipath fading characteristics of the channel, doppler effects, and blockage due to manmade objects as well as natural surroundings, characterization of the channel can be realized. Propogation experiments, then, are performed using a prototype of the system simulating the ultimate product environment. After the data from these experiments is generated, the researcher must access this data with a minimum of effort and to derive some standard results. The programs included in this package manipulate the data files generated by the NASA/JPL Mobile Satellite propogation experiment on an interactive basis. In the experiment, a transmitter operating at 869 MHz was carried to an altitude of 32Km by a stratospheric balloon. A vehicle within the line-of-sight of the transmitter was then driven around, splitting the incoming signal into I and Q channels, and sampling the resulting signal strength at 1000 samples per second. The data was collected at various antenna elavation angles and different times of day generating the ancillary data for the experiment. This package contains a program to convert the binary format of the data generated into standard ASCII format suitable for use with a wide variety of machine architectures. Also included is a UNIX shell-script designed to parse this ASCII file into those records of data that match the researcher's desired values for the ancillary data parameters. In addition, four FORTRAN programs are included to obtain standard quantities from the data. Quantities such as probability of signal level greater than or equal to a specified signal level, probability density of the signal levels, frequency of fade duration, and Fourier Transforms of the sampled data can be generated from the propogation experiment data. All programs in this package are written in either FORTRAN 77 or UNIX shell-scripts. The package does not include test data. The programs were developed in 1987 for use with a UNIX operating system on a DEC MicroVAX computer.

  2. Balanced Steady-State Free Precession (bSSFP) from an effective field perspective: Application to the detection of chemical exchange (bSSFPX).

    PubMed

    Zhang, Shu; Liu, Zheng; Grant, Aaron; Keupp, Jochen; Lenkinski, Robert E; Vinogradov, Elena

    2017-02-01

    Chemical exchange saturation transfer (CEST) is a novel contrast mechanism and it is gaining increasing popularity as many promising applications have been proposed and investigated. Fast and quantitative CEST imaging techniques are further needed in order to increase the applicability of CEST for clinical use as well as to derive quantitative physiological and biological information. Steady-state methods for fast CEST imaging have been reported recently. Here, we observe that an extreme case of these methods is a balanced steady-state free precession (bSSFP) sequence. The bSSFP in itself is sensitive to the exchange processes; hence, no additional saturation or preparation is needed for CEST-like data acquisition. The bSSFP experiment can be regarded as observation during saturation, without separate saturation and acquisition modules as used in standard CEST and similar experiments. One of the differences from standard CEST methods is that the bSSFP spectrum is an XY-spectrum not a Z-spectrum. As the first proof-of-principle step, we have implemented the steady-state bSSFP sequence for chemical exchange detection (bSSFPX) and verified its feasibility in phantom studies. These studies have shown that bSSFPX can achieve exchange-mediated contrast comparable to the standard CEST experiment. Therefore, the bSSFPX method has a potential for fast and quantitative CEST data acquisition. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Rational Manipulation of the Standard Laparoscopic Instruments for Single-Incision Laparoscopic Right Colectomy

    PubMed Central

    Watanabe, Makoto; Murakami, Masahiko; Kato, Takashi; Onaka, Toru; Aoki, Takeshi

    2013-01-01

    This report clarifies the rational manipulation of standard laparoscopic instruments for single-incision laparoscopic right colectomy (SILRC) using the SILS Port. We classified the manipulations required into 4 techniques. Vertical manipulation was required for medial-to-lateral retroperitoneal dissection. Frontal manipulation was needed for extension and establishment of a retroperitoneal plane. External crossing manipulation was used for dissection or ligation of the ileocolic or right colic vessels. Internal crossing manipulation was required for mobilization from the cecum to ascending colon. We performed SILRC for a series of 30 consecutive patients. One additional port was needed in 5 of the patients (16.7%) because of severe adhesion between the ileum and abdominal wall. No intraoperative complications were encountered. Four rational manipulations of the standard laparoscopic instruments are required for SILRC using the SILS Port. However, more experience and comparative trials are needed to determine the exact role of SILRC. PMID:23971771

  4. Quantification of HIV-1 DNA using real-time recombinase polymerase amplification.

    PubMed

    Crannell, Zachary Austin; Rohrman, Brittany; Richards-Kortum, Rebecca

    2014-06-17

    Although recombinase polymerase amplification (RPA) has many advantages for the detection of pathogenic nucleic acids in point-of-care applications, RPA has not yet been implemented to quantify sample concentration using a standard curve. Here, we describe a real-time RPA assay with an internal positive control and an algorithm that analyzes real-time fluorescence data to quantify HIV-1 DNA. We show that DNA concentration and the onset of detectable amplification are correlated by an exponential standard curve. In a set of experiments in which the standard curve and algorithm were used to analyze and quantify additional DNA samples, the algorithm predicted an average concentration within 1 order of magnitude of the correct concentration for all HIV-1 DNA concentrations tested. These results suggest that quantitative RPA (qRPA) may serve as a powerful tool for quantifying nucleic acids and may be adapted for use in single-sample point-of-care diagnostic systems.

  5. An automated digital data collection and analysis system for the Charpy Impact Tester

    NASA Technical Reports Server (NTRS)

    Kohne, Glenn S.; Spiegel, F. Xavier

    1994-01-01

    The standard Charpy Impact Tester has been modified by the addition of a system of hardware and software to improve the accuracy and consistency of measurements made during specimen fracturing experiments. An optical disc, light source, and detector generate signals that indicate the pendulum position as a function of time. These signals are used by a computer to calculate the velocity and kinetic energy of the pendulum as a function of its position.

  6. A general description of additive and nonadditive elements of sperm competitiveness and their relation to male fertilization success.

    PubMed

    Engqvist, Leif

    2013-05-01

    A complete understanding of male reproductive success, and thus sexual selection, often requires an insight into male success in sperm competition. Genuine conclusions on male sperm competitiveness can only be made in real competitive situations. However, statistical analyses of sperm competitiveness from fertilization success data have been shown to be problematic. Here, I first outline a comprehensive general description of the different additive and nonadditive elements relevant for the outcome of sperm competition staged between two males. Based on this description, I will highlight two main problems that are frequently encountered in experiments aiming at estimating sperm competitiveness. First, I focus on potential problems when using standardized competitors versus random mating trials, because trials with standardized competitors do not allow generalization if male-male interactions are important. Second, I illustrate the necessity to analyze data on the logit scale rather than on raw proportions, because only the logit scale allows a clean separation of additive and nonadditive effects (i.e., male × male and female × male interactions). © 2012 The Author(s). Evolution © 2012 The Society for the Study of Evolution.

  7. Model-independent constraints on modified gravity from current data and from the Euclid and SKA future surveys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taddei, Laura; Martinelli, Matteo; Amendola, Luca, E-mail: taddei@thphys.uni-heidelberg.de, E-mail: martinelli@lorentz.leidenuniv.nl, E-mail: amendola@thphys.uni-heidelberg.de

    2016-12-01

    The aim of this paper is to constrain modified gravity with redshift space distortion observations and supernovae measurements. Compared with a standard ΛCDM analysis, we include three additional free parameters, namely the initial conditions of the matter perturbations, the overall perturbation normalization, and a scale-dependent modified gravity parameter modifying the Poisson equation, in an attempt to perform a more model-independent analysis. First, we constrain the Poisson parameter Y (also called G {sub eff}) by using currently available f σ{sub 8} data and the recent SN catalog JLA. We find that the inclusion of the additional free parameters makes the constraintsmore » significantly weaker than when fixing them to the standard cosmological value. Second, we forecast future constraints on Y by using the predicted growth-rate data for Euclid and SKA missions. Here again we point out the weakening of the constraints when the additional parameters are included. Finally, we adopt as modified gravity Poisson parameter the specific Horndeski form, and use scale-dependent forecasts to build an exclusion plot for the Yukawa potential akin to the ones realized in laboratory experiments, both for the Euclid and the SKA surveys.« less

  8. The implications of renewable energy research and development: Policy scenario analysis with experience and learning effects

    NASA Astrophysics Data System (ADS)

    Kobos, Peter Holmes

    This dissertation analyzes the current and potential future costs of renewable energy technology from an institutional perspective. The central hypothesis is that reliable technology cost forecasting can be achieved through standard and modified experience curves implemented in a dynamic simulation model. Additionally, drawing upon region-specific institutional lessons highlights the role of market, social, and political institutions throughout an economy. Socio-political influences and government policy pathways drive resource allocation decisions that may be predominately influenced by factors other than those considered in a traditional market-driven, mechanistic approach. Learning in economic systems as a research topic is an attractive complement to the notion of institutional pathways. The economic implications of learning by doing, as first outlined by Arrow (1962), highlight decreasing production costs as individuals, or more generally the firm, become more familiar with a production process. The standard approach in the literature has been to employ a common experience curve where cumulative production is the only independent variable affecting costs. This dissertation develops a two factor experience curve, adding research, development and demonstration (RD&D) expenditures as a second variable. To illustrate the concept in the context of energy planning, two factor experience curves are developed for wind energy technology and solar photovoltaic (PV) modules under different assumptions on learning rates for cumulative capacity and the knowledge stock (a function of past RD&D efforts). Additionally, a one factor experience curve and cost trajectory scenarios are developed for concentrated solar power and geothermal energy technology, respectively. Cost forecasts are then developed for all four of these technologies in a dynamic simulation model. Combining the theoretical framework of learning by doing with the fields of organizational learning and institutional economics, this dissertation argues that the current state of renewable energy technology costs is largely due to the past production efforts (learning by doing) and RD&D efforts (learning by searching) in these global industries. This cost pathway, however, may be altered through several policy process feedback mechanisms including targeted RD&D expenditures, maintenance of RD&D to promote learning effects, and financial incentive programs that support energy production from renewable energy technologies.

  9. Effects of stimulus order on discrimination processes in comparative and equality judgements: data and models.

    PubMed

    Dyjas, Oliver; Ulrich, Rolf

    2014-01-01

    In typical discrimination experiments, participants are presented with a constant standard and a variable comparison stimulus and their task is to judge which of these two stimuli is larger (comparative judgement). In these experiments, discrimination sensitivity depends on the temporal order of these stimuli (Type B effect) and is usually higher when the standard precedes rather than follows the comparison. Here, we outline how two models of stimulus discrimination can account for the Type B effect, namely the weighted difference model (or basic Sensation Weighting model) and the Internal Reference Model. For both models, the predicted psychometric functions for comparative judgements as well as for equality judgements, in which participants indicate whether they perceived the two stimuli to be equal or not equal, are derived and it is shown that the models also predict a Type B effect for equality judgements. In the empirical part, the models' predictions are evaluated. To this end, participants performed a duration discrimination task with comparative judgements and with equality judgements. In line with the models' predictions, a Type B effect was observed for both judgement types. In addition, a time-order error, as indicated by shifts of the psychometric functions, and differences in response times were observed only for the equality judgement. Since both models entail distinct additional predictions, it seems worthwhile for future research to unite the two models into one conceptual framework.

  10. Percutaneous needle placement using laser guidance: a practical solution

    NASA Astrophysics Data System (ADS)

    Xu, Sheng; Kapoor, Ankur; Abi-Jaoudeh, Nadine; Imbesi, Kimberly; Hong, Cheng William; Mazilu, Dumitru; Sharma, Karun; Venkatesan, Aradhana M.; Levy, Elliot; Wood, Bradford J.

    2013-03-01

    In interventional radiology, various navigation technologies have emerged aiming to improve the accuracy of device deployment and potentially the clinical outcomes of minimally invasive procedures. While these technologies' performance has been explored extensively, their impact on daily clinical practice remains undetermined due to the additional cost and complexity, modification of standard devices (e.g. electromagnetic tracking), and different levels of experience among physicians. Taking these factors into consideration, a robotic laser guidance system for percutaneous needle placement is developed. The laser guidance system projects a laser guide line onto the skin entry point of the patient, helping the physician to align the needle with the planned path of the preoperative CT scan. To minimize changes to the standard workflow, the robot is integrated with the CT scanner via optical tracking. As a result, no registration between the robot and CT is needed. The robot can compensate for the motion of the equipment and keep the laser guide line aligned with the biopsy path in real-time. Phantom experiments showed that the guidance system can benefit physicians at different skill levels, while clinical studies showed improved accuracy over conventional freehand needle insertion. The technology is safe, easy to use, and does not involve additional disposable costs. It is our expectation that this technology can be accepted by interventional radiologists for CT guided needle placement procedures.

  11. Standard addition with internal standardisation as an alternative to using stable isotope labelled internal standards to correct for matrix effects-Comparison and validation using liquid chromatography-​tandem mass spectrometric assay of vitamin D.

    PubMed

    Hewavitharana, Amitha K; Abu Kassim, Nur Sofiah; Shaw, Paul Nicholas

    2018-06-08

    With mass spectrometric detection in liquid chromatography, co-eluting impurities affect the analyte response due to ion suppression/enhancement. Internal standard calibration method, using co-eluting stable isotope labelled analogue of each analyte as the internal standard, is the most appropriate technique available to correct for these matrix effects. However, this technique is not without drawbacks, proved to be expensive because separate internal standard for each analyte is required, and the labelled compounds are expensive or require synthesising. Traditionally, standard addition method has been used to overcome the matrix effects in atomic spectroscopy and was a well-established method. This paper proposes the same for mass spectrometric detection, and demonstrates that the results are comparable to those with the internal standard method using labelled analogues, for vitamin D assay. As conventional standard addition procedure does not address procedural errors, we propose the inclusion of an additional internal standard (not co-eluting). Recoveries determined on human serum samples show that the proposed method of standard addition yields more accurate results than the internal standardisation using stable isotope labelled analogues. The precision of the proposed method of standard addition is superior to the conventional standard addition method. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Incorporating Experience Curves in Appliance Standards Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garbesi, Karina; Chan, Peter; Greenblatt, Jeffery

    2011-10-31

    The technical analyses in support of U.S. energy conservation standards for residential appliances and commercial equipment have typically assumed that manufacturing costs and retail prices remain constant during the projected 30-year analysis period. There is, however, considerable evidence that this assumption does not reflect real market prices. Costs and prices generally fall in relation to cumulative production, a phenomenon known as experience and modeled by a fairly robust empirical experience curve. Using price data from the Bureau of Labor Statistics, and shipment data obtained as part of the standards analysis process, we present U.S. experience curves for room air conditioners,more » clothes dryers, central air conditioners, furnaces, and refrigerators and freezers. These allow us to develop more representative appliance price projections than the assumption-based approach of constant prices. These experience curves were incorporated into recent energy conservation standards for these products. The impact on the national modeling can be significant, often increasing the net present value of potential standard levels in the analysis. In some cases a previously cost-negative potential standard level demonstrates a benefit when incorporating experience. These results imply that past energy conservation standards analyses may have undervalued the economic benefits of potential standard levels.« less

  13. Treatment outcomes in palliative care: the TOPCare study. A mixed methods phase III randomised controlled trial to assess the effectiveness of a nurse-led palliative care intervention for HIV positive patients on antiretroviral therapy

    PubMed Central

    2012-01-01

    Background Patients with HIV/AIDS on Antiretroviral Therapy (ART) suffer from physical, psychological and spiritual problems. Despite international policy explicitly stating that a multidimensional approach such as palliative care should be delivered throughout the disease trajectory and alongside treatment, the effectiveness of this approach has not been tested in ART-experienced populations. Methods/design This mixed methods study uses a Randomised Controlled Trial (RCT) to test the null hypothesis that receipt of palliative care in addition to standard HIV care does not affect pain compared to standard care alone. An additional qualitative component will explore the mechanism of action and participant experience. The sample size is designed to detect a statistically significant decrease in reported pain, determined by a two tailed test and a p value of ≤0.05. Recruited patients will be adults on ART for more than one month, who report significant pain or symptoms which have lasted for more than two weeks (as measured by the African Palliative Care Association (APCA) African Palliative Outcome Scale (POS)). The intervention under trial is palliative care delivered by an existing HIV facility nurse trained to a set standard. Following an initial pilot the study will be delivered in two African countries, using two parallel independent Phase III clinical RCTs. Qualitative data will be collected from semi structured interviews and documentation from clinical encounters, to explore the experience of receiving palliative care in this context. Discussion The data provided by this study will provide evidence to inform the improvement of outcomes for people living with HIV and on ART in Africa. ClinicalTrials.gov Identifier: NCT01608802 PMID:23130740

  14. Inhibitory activity of a standardized elderberry liquid extract against clinically-relevant human respiratory bacterial pathogens and influenza A and B viruses

    PubMed Central

    2011-01-01

    Background Black elderberries (Sambucus nigra L.) are well known as supportive agents against common cold and influenza. It is further known that bacterial super-infection during an influenza virus (IV) infection can lead to severe pneumonia. We have analyzed a standardized elderberry extract (Rubini, BerryPharma AG) for its antimicrobial and antiviral activity using the microtitre broth micro-dilution assay against three Gram-positive bacteria and one Gram-negative bacteria responsible for infections of the upper respiratory tract, as well as cell culture experiments for two different strains of influenza virus. Methods The antimicrobial activity of the elderberry extract was determined by bacterial growth experiments in liquid cultures using the extract at concentrations of 5%, 10%, 15% and 20%. The inhibitory effects were determined by plating the bacteria on agar plates. In addition, the inhibitory potential of the extract on the propagation of human pathogenic H5N1-type influenza A virus isolated from a patient and an influenza B virus strain was investigated using MTT and focus assays. Results For the first time, it was shown that a standardized elderberry liquid extract possesses antimicrobial activity against both Gram-positive bacteria of Streptococcus pyogenes and group C and G Streptococci, and the Gram-negative bacterium Branhamella catarrhalis in liquid cultures. The liquid extract also displays an inhibitory effect on the propagation of human pathogenic influenza viruses. Conclusion Rubini elderberry liquid extract is active against human pathogenic bacteria as well as influenza viruses. The activities shown suggest that additional and alternative approaches to combat infections might be provided by this natural product. PMID:21352539

  15. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    USGS Publications Warehouse

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.

  16. Powder metallurgy: Solid and liquid phase sintering of copper

    NASA Technical Reports Server (NTRS)

    Sheldon, Rex; Weiser, Martin W.

    1993-01-01

    Basic powder metallurgy (P/M) principles and techniques are presented in this laboratory experiment. A copper based system is used since it is relatively easy to work with and is commercially important. In addition to standard solid state sintering, small quantities of low melting metals such as tin, zinc, lead, and aluminum can be added to demonstrate liquid phase sintering and alloy formation. The Taguchi Method of experimental design was used to study the effect of particle size, pressing force, sintering temperature, and sintering time. These parameters can be easily changed to incorporate liquid phase sintering effects and some guidelines for such substitutions are presented. The experiment is typically carried out over a period of three weeks.

  17. Hiring a Gay Man, Taking a Risk?: A Lab Experiment on Employment Discrimination and Risk Aversion.

    PubMed

    Baert, Stijn

    2018-01-01

    We investigate risk aversion as a driver of labor market discrimination against homosexual men. We show that more hiring discrimination by more risk-averse employers is consistent with taste-based and statistical discrimination. To test this hypothesis we conduct a scenario experiment in which experimental employers take a fictitious hiring decision concerning a heterosexual or homosexual male job candidate. In addition, participants are surveyed on their risk aversion and other characteristics that might correlate with this risk aversion. Analysis of the (post-)experimental data confirms our hypothesis. The likelihood of a beneficial hiring decision for homosexual male candidates decreases by 31.7% when employers are a standard deviation more risk-averse.

  18. Body image and sexual orientation: The experiences of lesbian and bisexual women.

    PubMed

    Smith, Marie L; Telford, Elina; Tree, Jeremy J

    2017-02-01

    Western cultures promote a thin and curvaceous ideal body size that most women find difficult to achieve by healthy measures, resulting in poor body image and increased risk for eating pathology. Research focusing on body image in lesbian and bisexual women has yielded inconsistent results. In total, 11 lesbian and bisexual women were interviewed regarding their experiences with body image. Interpretative phenomenological analysis revealed that these women experienced similar mainstream pressures to conform to a thin body ideal. Furthermore, participants perceived additional pressure to conform to heteronormative standards of beauty since the normalisation of homosexuality and the increase in Lesbian, Gay, Bisexual and Transgender representation in mainstream media.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelly, Kevin J.; Parke, Stephen J.

    Quantum mechanical interactions between neutrinos and matter along the path of propagation, the Wolfenstein matter effect, are of particular importance for the upcoming long-baseline neutrino oscillation experiments, specifically the Deep Underground Neutrino Experiment (DUNE). Here, we explore specifically what about the matter density profile can be measured by DUNE, considering both the shape and normalization of the profile between the neutrinos' origin and detection. Additionally, we explore the capability of a perturbative method for calculating neutrino oscillation probabilities and whether this method is suitable for DUNE. We also briefly quantitatively explore the ability of DUNE to measure the Earth's mattermore » density, and the impact of performing this measurement on measuring standard neutrino oscillation parameters.« less

  20. Lorentz and CPT Tests with Atoms

    NASA Astrophysics Data System (ADS)

    Vargas Silva, Arnaldo J.

    The prospects for using atomic-spectroscopy experiments to test Lorentz and CPT symmetry are investigated. Phenomenological models for Lorentz violation studied in this work include ones with contributions from all quadratic operators for a Dirac fermion in the Lagrange density of the Standard-Model Extension (SME), without restriction on the operator mass dimension. The systems considered include atoms composed of conventional matter, antimatter, and second-generation particles. Generic expressions for the Lorentz-violating energy shifts applicable to a broad range of atomic transitions are obtained. Signals for Lorentz violation that can in principle be studied in spectroscopic experiments are identified from the theoretical corrections to the spectrum. Some of these signals include sidereal and annual variations of atomic transition frequencies measured in a laboratory on the surface of the Earth. Other possibilities include effects produced by changing the orientation of the applied magnetic field or by realizing space-based experiments. Discrepancies in the experimental values for fundamental constants and energy levels based on self-consistent predictions from the Standard Model also offer potential signals for Lorentz violation. The sensitivities of different experiments to distinct sets of coefficients for Lorentz violation are considered. Using atoms composed of different particle species allows measurements of coefficients for Lorentz violation in different fermion sectors of the SME. Experiments comparing hydrogen and antihydrogen can discriminate between coefficients for Lorentz violation that are associated with CPT-odd or CPT-even operators. Additionally, certain systems and transitions are more sensitive to nonminimal operators, while others are particularly sensitive to minimal ones.

  1. A comprehensive quality control workflow for paired tumor-normal NGS experiments.

    PubMed

    Schroeder, Christopher M; Hilke, Franz J; Löffler, Markus W; Bitzer, Michael; Lenz, Florian; Sturm, Marc

    2017-06-01

    Quality control (QC) is an important part of all NGS data analysis stages. Many available tools calculate QC metrics from different analysis steps of single sample experiments (raw reads, mapped reads and variant lists). Multi-sample experiments, as sequencing of tumor-normal pairs, require additional QC metrics to ensure validity of results. These multi-sample QC metrics still lack standardization. We therefore suggest a new workflow for QC of DNA sequencing of tumor-normal pairs. With this workflow well-known single-sample QC metrics and additional metrics specific for tumor-normal pairs can be calculated. The segmentation into different tools offers a high flexibility and allows reuse for other purposes. All tools produce qcML, a generic XML format for QC of -omics experiments. qcML uses quality metrics defined in an ontology, which was adapted for NGS. All QC tools are implemented in C ++ and run both under Linux and Windows. Plotting requires python 2.7 and matplotlib. The software is available under the 'GNU General Public License version 2' as part of the ngs-bits project: https://github.com/imgag/ngs-bits. christopher.schroeder@med.uni-tuebingen.de. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  2. The target-to-foils shift in simultaneous and sequential lineups.

    PubMed

    Clark, Steven E; Davey, Sherrie L

    2005-04-01

    A theoretical cornerstone in eyewitness identification research is the proposition that witnesses, in making decisions from standard simultaneous lineups, make relative judgments. The present research considers two sources of support for this proposal. An experiment by G. L. Wells (1993) showed that if the target is removed from a lineup, witnesses shift their responses to pick foils, rather than rejecting the lineups, a result we will term a target-to-foils shift. Additional empirical support is provided by results from sequential lineups which typically show higher accuracy than simultaneous lineups, presumably because of a decrease in the use of relative judgments in making identification decisions. The combination of these two lines of research suggests that the target-to-foils shift should be reduced in sequential lineups relative to simultaneous lineups. Results of two experiments showed an overall advantage for sequential lineups, but also showed a target-to-foils shift equal in size for simultaneous and sequential lineups. Additional analyses indicated that the target-to-foils shift in sequential lineups was moderated in part by an order effect and was produced with (Experiment 2) or without (Experiment 1) a shift in decision criterion. This complex pattern of results suggests that more work is needed to understand the processes which underlie decisions in simultaneous and sequential lineups.

  3. Object width modulates object-based attentional selection.

    PubMed

    Nah, Joseph C; Neppi-Modona, Marco; Strother, Lars; Behrmann, Marlene; Shomstein, Sarah

    2018-04-24

    Visual input typically includes a myriad of objects, some of which are selected for further processing. While these objects vary in shape and size, most evidence supporting object-based guidance of attention is drawn from paradigms employing two identical objects. Importantly, object size is a readily perceived stimulus dimension, and whether it modulates the distribution of attention remains an open question. Across four experiments, the size of the objects in the display was manipulated in a modified version of the two-rectangle paradigm. In Experiment 1, two identical parallel rectangles of two sizes (thin or thick) were presented. Experiments 2-4 employed identical trapezoids (each having a thin and thick end), inverted in orientation. In the experiments, one end of an object was cued and participants performed either a T/L discrimination or a simple target-detection task. Combined results show that, in addition to the standard object-based attentional advantage, there was a further attentional benefit for processing information contained in the thick versus thin end of objects. Additionally, eye-tracking measures demonstrated increased saccade precision towards thick object ends, suggesting that Fitts's Law may play a role in object-based attentional shifts. Taken together, these results suggest that object-based attentional selection is modulated by object width.

  4. Protecting the rights of producers original medicines.

    PubMed

    Pashkov, Vitalii; Kotvitska, Alla; Noha, Petro

    the article analyzes the state of protection of intellectual property rights of original medicine producers, its accordance with international standards. Attention is focused on the importance of exclusivity of medicine market. the analysis of protection of intellectual property rights of medicine producers in Ukraine and determination of its conformity or non-conformity to the international standards. the experience of certain countries is analyzed in the research. Additionally, we used statistical data of international organizations, conclusions of experts. there are numerous cases of state registration of generic medicinal products using the registration information of original medicinal products and delict of the rights of patent holders. an effective mechanism of judicial protection of the original medicine producers` intellectual property rights from disorders that affect the profit was elaborated in Ukraine.

  5. Data Standards for Omics Data: The Basis of Data Sharing and Reuse

    PubMed Central

    Chervitz, Stephen A.; Deutsch, Eric W.; Field, Dawn; Parkinson, Helen; Quackenbush, John; Rocca-Serra, Phillipe; Sansone, Susanna-Assunta; Stoeckert, Christian J.; Taylor, Chris F.; Taylor, Ronald; Ball, Catherine A.

    2014-01-01

    To facilitate sharing of Omics data, many groups of scientists have been working to establish the relevant data standards. The main components of data sharing standards are experiment description standards, data exchange standards, terminology standards, and experiment execution standards. Here we provide a survey of existing and emerging standards that are intended to assist the free and open exchange of large-format data. PMID:21370078

  6. Antenatal needs of couples following fertility treatment: a qualitative study in primary care

    PubMed Central

    French, Lydia RM; Sharp, Debbie J; Turner, Katrina M

    2015-01-01

    Background It is known that couples may experience emotional distress while undergoing infertility treatment, but less is known about their experience of pregnancy following successful conception. Typically, couples are discharged from the fertility clinic to receive standard antenatal care. Recent research has raised questions about whether this care adequately meets their needs. Aim To explore the antenatal experiences of females and males who have successfully conceived through infertility treatment. Design and setting An exploratory qualitative approach was undertaken, using individual, in-depth interviews with females and males who had successfully undergone infertility treatment in one of three fertility clinics in the south of England. Method Twenty participants were interviewed (12 females and eight male partners) when their pregnancy had reached 28 weeks’ gestation. Participants were asked about their experiences of infertility treatment, pregnancy, and antenatal care. Interviews were audiorecorded, transcribed, and analysed thematically. Results Analysis of the interviews suggested females and males experienced a ‘gap’ in their care, in terms of time and intensity, when discharged from the fertility clinic to standard antenatal care. This gap, combined with their previous experience of infertility treatment, heightened their fear of pregnancy loss and increased their need for support from their health professionals. Participants’ previous experience of infertility treatment also appeared to deter them from preparing for the birth and parenthood, and disclosing negative feelings to others about the pregnancy. Conclusion Females and males who have successfully undergone infertility treatment may require additional support in primary care to address anxiety during pregnancy, enable disclosure of negative feelings, and to help them prepare for childbirth and parenthood. PMID:26324493

  7. 21 CFR 170.10 - Food additives in standardized foods.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Food additives in standardized foods. 170.10... (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES General Provisions § 170.10 Food additives... the Act, which proposes the inclusion of a food additive in such definition and standard of identity...

  8. 21 CFR 170.10 - Food additives in standardized foods.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Food additives in standardized foods. 170.10... (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES General Provisions § 170.10 Food additives... the Act, which proposes the inclusion of a food additive in such definition and standard of identity...

  9. 21 CFR 170.10 - Food additives in standardized foods.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Food additives in standardized foods. 170.10... (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES General Provisions § 170.10 Food additives... the Act, which proposes the inclusion of a food additive in such definition and standard of identity...

  10. 21 CFR 170.10 - Food additives in standardized foods.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Food additives in standardized foods. 170.10... (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) FOOD ADDITIVES General Provisions § 170.10 Food additives... the Act, which proposes the inclusion of a food additive in such definition and standard of identity...

  11. Advancing nutritional therapy: A novel polymeric formulation attenuates intestinal inflammation in a murine colitis model and suppresses pro-inflammatory cytokine production in ex-vivo cultured inflamed colonic biopsies.

    PubMed

    Alhagamhmad, Moftah H; Lemberg, Daniel A; Day, Andrew S; Tan, Li-Zsa; Ooi, Chee Y; Krishnan, Usha; Gupta, Nitin; Munday, John S; Leach, Steven T

    2017-04-01

    Nutritional therapy is a viable therapeutic option for the treatment of Crohn disease (CD). Therefore improving nutritional therapy would greatly benefit CD patients. The aim of this study was to define the anti-inflammatory properties of a novel nutritional polymeric formula (PF) in comparison to a currently available standard PF. Dextran sodium sulfate (DSS) was utilized to induce colitis in C57BL/6 mice with mice randomized to receive either standard PF or novel PF in addition to control groups. Changes in body weight were recorded and colonic damage was assessed histologically and biochemically. Additional experiments were also included where the cytokine response of colonic biopsies from pediatric CD patients was measured following exposure to standard PF or novel PF. DSS induced significant body weight loss, morphological changes in the colon, increased myeloperoxidase (MPO) activity and up-regulated colonic mRNA expression of tumor necrosis factor (TNF)-α, interleukin (IL)-6, IL-12 and monocyte chemoattractant protein (MCP)-1, as well as associated histological changes. Other than histological damage, these inflammatory changes were reversed by both novel and standard PF. However, the novel PF, but not standard PF, completely suppressed TNF-α, IL-6 and IL-8 levels from cultured biopsies. Newly developed nutritional formula reproducibly ameliorated DSS-induced colitis in a murine model, although this response was not measurably different to standard PF. However, the novel PF was significantly superior in suppressing inflammatory cytokine release from cultured colonic biopsies. Collectively, these findings support a possible role for novel PF in advancing nutritional therapy for CD patients. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. The effect of surface boundary conditions on the climate generated by a coarse-mesh general circulation model

    NASA Technical Reports Server (NTRS)

    Cohen, C.

    1981-01-01

    A hierarchy of experiments was run, starting with an all water planet with zonally symmetric sea surface temperatures, then adding, one at a time, flat continents, mountains, surface physics, and realistic sea surface temperatures. The model was run with the sun fixed at a perpetual January. Ensemble means and standard deviations were computed and the t-test was used to determine the statistical significance of the results. The addition of realistic surface physics does not affect the model climatology to as large as extent as does the addition of mountains. Departures from zonal symmetry of the SST field result in a better simulation of the real atmosphere.

  13. A Routine Experimental Protocol for qHNMR Illustrated with Taxol⊥

    PubMed Central

    Pauli, Guido F.; Jaki, Birgit U.; Lankin, David C.

    2012-01-01

    Quantitative 1H NMR (qHNMR) provides a value-added dimension to the standard spectroscopic data set involved in structure analysis, especially when analyzing bioactive molecules and elucidating new natural products. The qHNMR method can be integrated into any routine qualitative workflow without much additional effort by simply establishing quantitative conditions for the standard solution 1H NMR experiments. Moreover, examination of different chemical lots of taxol and a Taxus brevifolia extract as working examples led to a blueprint for a generic approach to performing a routinely practiced 13C-decoupled qHNMR experiment, and for recognizing its potential and main limitations. The proposed protocol is based on a newly assembled 13C GARP broadband decoupled proton acquisition sequence that reduces spectroscopic complexity by removal of carbon satellites. The method is capable of providing qualitative and quantitative NMR data simultaneously and covers various analytes from pure compounds to complex mixtures such as metabolomes. Due to a routinely achievable dynamic range of 300:1 (0.3%) or better, qHNMR qualifies for applications ranging from reference standards to biologically active compounds to metabolome analysis. Providing a “cookbook” approach to qHNMR, acquisition conditions are described that can be adapted for contemporary NMR spectrometers of all major manufacturers. PMID:17298095

  14. A proposed protocol for acceptance and constancy control of computed tomography systems: a Nordic Association for Clinical Physics (NACP) work group report.

    PubMed

    Kuttner, Samuel; Bujila, Robert; Kortesniemi, Mika; Andersson, Henrik; Kull, Love; Østerås, Bjørn Helge; Thygesen, Jesper; Tarp, Ivanka Sojat

    2013-03-01

    Quality assurance (QA) of computed tomography (CT) systems is one of the routine tasks for medical physicists in the Nordic countries. However, standardized QA protocols do not yet exist and the QA methods, as well as the applied tolerance levels, vary in scope and extent at different hospitals. To propose a standardized protocol for acceptance and constancy testing of CT scanners in the Nordic Region. Following a Nordic Association for Clinical Physics (NACP) initiative, a group of medical physicists, with representatives from four Nordic countries, was formed. Based on international literature and practical experience within the group, a comprehensive standardized test protocol was developed. The proposed protocol includes tests related to the mechanical functionality, X-ray tube, detector, and image quality for CT scanners. For each test, recommendations regarding the purpose, equipment needed, an outline of the test method, the measured parameter, tolerance levels, and the testing frequency are stated. In addition, a number of optional tests are briefly discussed that may provide further information about the CT system. Based on international references and medical physicists' practical experiences, a comprehensive QA protocol for CT systems is proposed, including both acceptance and constancy tests. The protocol may serve as a reference for medical physicists in the Nordic countries.

  15. Toward reliable biomarker signatures in the age of liquid biopsies - how to standardize the small RNA-Seq workflow

    PubMed Central

    Buschmann, Dominik; Haberberger, Anna; Kirchner, Benedikt; Spornraft, Melanie; Riedmaier, Irmgard; Schelling, Gustav; Pfaffl, Michael W.

    2016-01-01

    Small RNA-Seq has emerged as a powerful tool in transcriptomics, gene expression profiling and biomarker discovery. Sequencing cell-free nucleic acids, particularly microRNA (miRNA), from liquid biopsies additionally provides exciting possibilities for molecular diagnostics, and might help establish disease-specific biomarker signatures. The complexity of the small RNA-Seq workflow, however, bears challenges and biases that researchers need to be aware of in order to generate high-quality data. Rigorous standardization and extensive validation are required to guarantee reliability, reproducibility and comparability of research findings. Hypotheses based on flawed experimental conditions can be inconsistent and even misleading. Comparable to the well-established MIQE guidelines for qPCR experiments, this work aims at establishing guidelines for experimental design and pre-analytical sample processing, standardization of library preparation and sequencing reactions, as well as facilitating data analysis. We highlight bottlenecks in small RNA-Seq experiments, point out the importance of stringent quality control and validation, and provide a primer for differential expression analysis and biomarker discovery. Following our recommendations will encourage better sequencing practice, increase experimental transparency and lead to more reproducible small RNA-Seq results. This will ultimately enhance the validity of biomarker signatures, and allow reliable and robust clinical predictions. PMID:27317696

  16. Determinations of rare earth element abundance and U-Pb age of zircons using multispot laser ablation-inductively coupled plasma mass spectrometry.

    PubMed

    Yokoyama, Takaomi D; Suzuki, Toshihiro; Kon, Yoshiaki; Hirata, Takafumi

    2011-12-01

    We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Prešovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.

  17. NCBI GEO: archive for high-throughput functional genomic data.

    PubMed

    Barrett, Tanya; Troup, Dennis B; Wilhite, Stephen E; Ledoux, Pierre; Rudnev, Dmitry; Evangelista, Carlos; Kim, Irene F; Soboleva, Alexandra; Tomashevsky, Maxim; Marshall, Kimberly A; Phillippy, Katherine H; Sherman, Patti M; Muertter, Rolf N; Edgar, Ron

    2009-01-01

    The Gene Expression Omnibus (GEO) at the National Center for Biotechnology Information (NCBI) is the largest public repository for high-throughput gene expression data. Additionally, GEO hosts other categories of high-throughput functional genomic data, including those that examine genome copy number variations, chromatin structure, methylation status and transcription factor binding. These data are generated by the research community using high-throughput technologies like microarrays and, more recently, next-generation sequencing. The database has a flexible infrastructure that can capture fully annotated raw and processed data, enabling compliance with major community-derived scientific reporting standards such as 'Minimum Information About a Microarray Experiment' (MIAME). In addition to serving as a centralized data storage hub, GEO offers many tools and features that allow users to effectively explore, analyze and download expression data from both gene-centric and experiment-centric perspectives. This article summarizes the GEO repository structure, content and operating procedures, as well as recently introduced data mining features. GEO is freely accessible at http://www.ncbi.nlm.nih.gov/geo/.

  18. Is performance in task-cuing experiments mediated by task set selection or associative compound retrieval?

    PubMed

    Forrest, Charlotte L D; Monsell, Stephen; McLaren, Ian P L

    2014-07-01

    Task-cuing experiments are usually intended to explore control of task set. But when small stimulus sets are used, they plausibly afford learning of the response associated with a combination of cue and stimulus, without reference to tasks. In 3 experiments we presented the typical trials of a task-cuing experiment: a cue (colored shape) followed, after a short or long interval, by a digit to which 1 of 2 responses was required. In a tasks condition, participants were (as usual) directed to interpret the cue as an instruction to perform either an odd/even or a high/low classification task. In a cue + stimulus → response (CSR) condition, to induce learning of mappings between cue-stimulus compound and response, participants were, in Experiment 1, given standard task instructions and additionally encouraged to learn the CSR mappings; in Experiment 2, informed of all the CSR mappings and asked to learn them, without standard task instructions; in Experiment 3, required to learn the mappings by trial and error. The effects of a task switch, response congruence, preparation, and transfer to a new set of stimuli differed substantially between the conditions in ways indicative of classification according to task rules in the tasks condition, and retrieval of responses specific to stimulus-cue combinations in the CSR conditions. Qualitative features of the latter could be captured by an associative learning network. Hence associatively based compound retrieval can serve as the basis for performance with a small stimulus set. But when organization by tasks is apparent, control via task set selection is the natural and efficient strategy. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  19. Fear of childbirth in expectant fathers, subsequent childbirth experience and impact of antenatal education: subanalysis of results from a randomized controlled trial.

    PubMed

    Bergström, Malin; Rudman, Ann; Waldenström, Ulla; Kieler, Helle

    2013-08-01

    To explore if antenatal fear of childbirth in men affects their experience of the birth event and if this experience is associated with type of childbirth preparation. Data from a randomized controlled multicenter trial on antenatal education. 15 antenatal clinics in Sweden between January 2006 and May 2007. 762 men, of whom 83 (10.9%) suffered from fear of childbirth. Of these 83 men, 39 were randomized to psychoprophylaxis childbirth preparation where men were trained to coach their partners during labor and 44 to standard care antenatal preparation for childbirth and parenthood without such training. Experience of childbirth was compared between men with and without fear of childbirth regardless of randomization, and between fearful men in the randomized groups. Analyses by logistic regression adjusted for sociodemographic variables. Self-reported data on experience of childbirth including an adapted version of the Wijma Delivery Experience Questionnaire (W-DEQ B). Men with antenatal fear of childbirth more often experienced childbirth as frightening than men without fear: adjusted odds ratio 4.68, 95% confidence interval 2.67-8.20. Men with antenatal fear in the psychoprophylaxis group rated childbirth as frightening less often than those in standard care: adjusted odds ratio 0.30, 95% confidence interval 0.10-0.95. Men who suffer from antenatal fear of childbirth are at higher risk of experiencing childbirth as frightening. Childbirth preparation including training as a coach may help fearful men to a more positive childbirth experience. Additional studies are needed to support this conclusion. © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

  20. Women's experiences of having a Bachelor of Midwifery student provide continuity of care.

    PubMed

    Tickle, N; Sidebotham, M; Fenwick, J; Gamble, J

    2016-06-01

    The Australian national midwifery education standards require students to complete a number of continuity of care (COC) experiences. There is increasing evidence outlining the value of this experience to the student, but there is limited research examining women's experiences of having a COC midwifery student. This study aimed to investigates the woman's experiences. A retrospective descriptive cohort design was used. A paper-based survey was posted to all women cared for by a midwifery student in 2013 (n=698). Descriptive statistics were used to explore the proportion, mean score, standard deviation and range of the variables. Construct validity of the Satisfaction and Respect Scales was tested using exploratory factor analysis. Free text responses were analysed using latent content analysis. One-third of women returned a completed survey (n=237/698, 34%). There was a significant positive correlation (p<0.05) between the number of AN/PN visits a midwifery student attended and women's levels of satisfaction. Women were very satisfied with having a student midwife provide continuity. The qualitative data provided additional insight demonstrating that most women had a positive relationship with the midwifery student that enhanced their childbearing experience. The women in this study valued continuity of midwifery care and were able to form meaningful relationships with their midwifery student. Programs leading to registration as a midwife should privilege continuity of care experiences. Not only does this benefit women but provides the future midwifery workforce with a clear understanding of models that best meet women's individual and the benefits of working in these models. Copyright © 2015 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  1. Dynamic provisioning of local and remote compute resources with OpenStack

    NASA Astrophysics Data System (ADS)

    Giffels, M.; Hauth, T.; Polgart, F.; Quast, G.

    2015-12-01

    Modern high-energy physics experiments rely on the extensive usage of computing resources, both for the reconstruction of measured events as well as for Monte-Carlo simulation. The Institut fur Experimentelle Kernphysik (EKP) at KIT is participating in both the CMS and Belle experiments with computing and storage resources. In the upcoming years, these requirements are expected to increase due to growing amount of recorded data and the rise in complexity of the simulated events. It is therefore essential to increase the available computing capabilities by tapping into all resource pools. At the EKP institute, powerful desktop machines are available to users. Due to the multi-core nature of modern CPUs, vast amounts of CPU time are not utilized by common desktop usage patterns. Other important providers of compute capabilities are classical HPC data centers at universities or national research centers. Due to the shared nature of these installations, the standardized software stack required by HEP applications cannot be installed. A viable way to overcome this constraint and offer a standardized software environment in a transparent manner is the usage of virtualization technologies. The OpenStack project has become a widely adopted solution to virtualize hardware and offer additional services like storage and virtual machine management. This contribution will report on the incorporation of the institute's desktop machines into a private OpenStack Cloud. The additional compute resources provisioned via the virtual machines have been used for Monte-Carlo simulation and data analysis. Furthermore, a concept to integrate shared, remote HPC centers into regular HEP job workflows will be presented. In this approach, local and remote resources are merged to form a uniform, virtual compute cluster with a single point-of-entry for the user. Evaluations of the performance and stability of this setup and operational experiences will be discussed.

  2. Multivariate Statistics Applied to Seismic Phase Picking

    NASA Astrophysics Data System (ADS)

    Velasco, A. A.; Zeiler, C. P.; Anderson, D.; Pingitore, N. E.

    2008-12-01

    The initial effort of the Seismogram Picking Error from Analyst Review (SPEAR) project has been to establish a common set of seismograms to be picked by the seismological community. Currently we have 13 analysts from 4 institutions that have provided picks on the set of 26 seismograms. In comparing the picks thus far, we have identified consistent biases between picks from different institutions; effects of the experience of analysts; and the impact of signal-to-noise on picks. The institutional bias in picks brings up the important concern that picks will not be the same between different catalogs. This difference means less precision and accuracy when combing picks from multiple institutions. We also note that depending on the experience level of the analyst making picks for a catalog the error could fluctuate dramatically. However, the experience level is based off of number of years in picking seismograms and this may not be an appropriate criterion for determining an analyst's precision. The common data set of seismograms provides a means to test an analyst's level of precision and biases. The analyst is also limited by the quality of the signal and we show that the signal-to-noise ratio and pick error are correlated to the location, size and distance of the event. This makes the standard estimate of picking error based on SNR more complex because additional constraints are needed to accurately constrain the measurement error. We propose to extend the current measurement of error by adding the additional constraints of institutional bias and event characteristics to the standard SNR measurement. We use multivariate statistics to model the data and provide constraints to accurately assess earthquake location and measurement errors.

  3. Data File Standard for Flow Cytometry, version FCS 3.1.

    PubMed

    Spidlen, Josef; Moore, Wayne; Parks, David; Goldberg, Michael; Bray, Chris; Bierre, Pierre; Gorombey, Peter; Hyun, Bill; Hubbard, Mark; Lange, Simon; Lefebvre, Ray; Leif, Robert; Novo, David; Ostruszka, Leo; Treister, Adam; Wood, James; Murphy, Robert F; Roederer, Mario; Sudar, Damir; Zigon, Robert; Brinkman, Ryan R

    2010-01-01

    The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allows files created by one type of acquisition hardware and software to be analyzed by any other type.The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.

  4. Data File Standard for Flow Cytometry, Version FCS 3.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spidlen, Josef; Moore, Wayne; Parks, David

    2009-11-10

    The flow cytometry data file standard provides the specifications needed to completely describe flow cytometry data sets within the confines of the file containing the experimental data. In 1984, the first Flow Cytometry Standard format for data files was adopted as FCS 1.0. This standard was modified in 1990 as FCS 2.0 and again in 1997 as FCS 3.0. We report here on the next generation flow cytometry standard data file format. FCS 3.1 is a minor revision based on suggested improvements from the community. The unchanged goal of the standard is to provide a uniform file format that allowsmore » files created by one type of acquisition hardware and software to be analyzed by any other type. The FCS 3.1 standard retains the basic FCS file structure and most features of previous versions of the standard. Changes included in FCS 3.1 address potential ambiguities in the previous versions and provide a more robust standard. The major changes include simplified support for international characters and improved support for storing compensation. The major additions are support for preferred display scale, a standardized way of capturing the sample volume, information about originality of the data file, and support for plate and well identification in high throughput, plate based experiments. Please see the normative version of the FCS 3.1 specification in Supporting Information for this manuscript (or at http://www.isac-net.org/ in the Current standards section) for a complete list of changes.« less

  5. Simplification and improvement of protein detection in two-dimensional electrophoresis gels with SERVA HPE™ lightning red.

    PubMed

    Griebel, Anja; Obermaier, Christian; Westermeier, Reiner; Moche, Martin; Büttner, Knut

    2013-07-01

    A new fluorescent amino-reactive dye has been tested for both labelling proteins prior to electrophoretic separations and between the two steps of two-dimensional electrophoresis. A series of experiments showed, that the labelling of lysines with this dye is compatible with all standard additives used for sample preparation, including reducing substances and carrier ampholytes. Using this dye for pre-labelling considerably simplifies the electrophoresis and detection workflow and provides highly sensitive and quantitative visualisation of proteins.

  6. Study protocol: an early intervention program to improve motor outcome in preterm infants: a randomized controlled trial and a qualitative study of physiotherapy performance and parental experiences

    PubMed Central

    2012-01-01

    Abstract Background Knowledge about early physiotherapy to preterm infants is sparse, given the risk of delayed motor development and cerebral palsy. Methods/Design A pragmatic randomized controlled study has been designed to assess the effect of a preventative physiotherapy program carried out in the neonatal intensive care unit. Moreover, a qualitative study is carried out to assess the physiotherapy performance and parents' experiences with the intervention. The aim of the physiotherapy program is to improve motor development i.e. postural control and selective movements in these infants. 150 infants will be included and randomized to either intervention or standard follow-up. The infants in the intervention group will be given specific stimulation to facilitate movements based on the individual infant's development, behavior and needs. The physiotherapist teaches the parents how to do the intervention and the parents receive a booklet with photos and descriptions of the intervention. Intervention is carried out twice a day for three weeks (week 34, 35, 36 postmenstrual age). Standardized tests are carried out at baseline, term age and at three, six, 12 and 24 months corrected age. In addition eight triads (infant, parent and physiotherapist) are observed and videotaped in four clinical encounters each to assess the process of physiotherapy performance. The parents are also interviewed on their experiences with the intervention and how it influences on the parent-child relationship. Eight parents from the follow up group are interviewed about their experience. The interviews are performed according to the same schedule as the standardized measurements. Primary outcome is at two years corrected age. Discussion The paper presents the protocol for a randomized controlled trial designed to study the effect of physiotherapy to preterm infants at neonatal intensive care units. It also studies physiotherapy performance and the parent's experiences with the intervention. Trial registration ClinicalTrials.gov NCT01089296 PMID:22336194

  7. Barriers to success: physical separation optimizes event-file retrieval in shared workspaces.

    PubMed

    Klempova, Bibiana; Liepelt, Roman

    2017-07-08

    Sharing tasks with other persons can simplify our work and life, but seeing and hearing other people's actions may also be very distracting. The joint Simon effect (JSE) is a standard measure of referential response coding when two persons share a Simon task. Sequential modulations of the joint Simon effect (smJSE) are interpreted as a measure of event-file processing containing stimulus information, response information and information about the just relevant control-state active in a given social situation. This study tested effects of physical (Experiment 1) and virtual (Experiment 2) separation of shared workspaces on referential coding and event-file processing using a joint Simon task. In Experiment 1, participants performed this task in individual (go-nogo), joint and standard Simon task conditions with and without a transparent curtain (physical separation) placed along the imagined vertical midline of the monitor. In Experiment 2, participants performed the same tasks with and without receiving background music (virtual separation). For response times, physical separation enhanced event-file retrieval indicated by an enlarged smJSE in the joint Simon task with curtain than without curtain (Experiment1), but did not change referential response coding. In line with this, we also found evidence for enhanced event-file processing through physical separation in the joint Simon task for error rates. Virtual separation did neither impact event-file processing, nor referential coding, but generally slowed down response times in the joint Simon task. For errors, virtual separation hampered event-file processing in the joint Simon task. For the cognitively more demanding standard two-choice Simon task, we found music to have a degrading effect on event-file retrieval for response times. Our findings suggest that adding a physical separation optimizes event-file processing in shared workspaces, while music seems to lead to a more relaxed task processing mode under shared task conditions. In addition, music had an interfering impact on joint error processing and more generally when dealing with a more complex task in isolation.

  8. With the Advent of Tomosynthesis in the Workup of Mammographic Abnormality, is Spot Compression Mammography Now Obsolete? An Initial Clinical Experience.

    PubMed

    Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha

    2017-09-01

    To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.

  9. Microbial production of scleroglucan and downstream processing.

    PubMed

    Castillo, Natalia A; Valdez, Alejandra L; Fariña, Julia I

    2015-01-01

    Synthetic petroleum-based polymers and natural plant polymers have the disadvantage of restricted sources, in addition to the non-biodegradability of the former ones. In contrast, eco-sustainable microbial polysaccharides, of low-cost and standardized production, represent an alternative to address this situation. With a strong global market, they attracted worldwide attention because of their novel and unique physico-chemical properties as well as varied industrial applications, and many of them are promptly becoming economically competitive. Scleroglucan, a β-1,3-β-1,6-glucan secreted by Sclerotium fungi, exhibits high potential for commercialization and may show different branching frequency, side-chain length, and/or molecular weight depending on the producing strain or culture conditions. Water-solubility, viscosifying ability and wide stability over temperature, pH and salinity make scleroglucan useful for different biotechnological (enhanced oil recovery, food additives, drug delivery, cosmetic and pharmaceutical products, biocompatible materials, etc.), and biomedical (immunoceutical, antitumor, etc.) applications. It can be copiously produced at bioreactor scale under standardized conditions, where a high exopolysaccharide concentration normally governs the process optimization. Operative and nutritional conditions, as well as the incidence of scleroglucan downstream processing will be discussed in this chapter. The relevance of using standardized inocula from selected strains and experiences concerning the intricate scleroglucan scaling-up will be also herein outlined.

  10. Phytotoxicity and accumulation of chromium in carrot plants and the derivation of soil thresholds for Chinese soils.

    PubMed

    Ding, Changfeng; Li, Xiaogang; Zhang, Taolin; Ma, Yibing; Wang, Xingxiang

    2014-10-01

    Soil environmental quality standards in respect of heavy metals for farmlands should be established considering both their effects on crop yield and their accumulation in the edible part. A greenhouse experiment was conducted to investigate the effects of chromium (Cr) on biomass production and Cr accumulation in carrot plants grown in a wide range of soils. The results revealed that carrot yield significantly decreased in 18 of the total 20 soils with Cr addition being the soil environmental quality standard of China. The Cr content of carrot grown in the five soils with pH>8.0 exceeded the maximum allowable level (0.5mgkg(-1)) according to the Chinese General Standard for Contaminants in Foods. The relationship between carrot Cr concentration and soil pH could be well fitted (R(2)=0.70, P<0.0001) by a linear-linear segmented regression model. The addition of Cr to soil influenced carrot yield firstly rather than the food quality. The major soil factors controlling Cr phytotoxicity and the prediction models were further identified and developed using path analysis and stepwise multiple linear regression analysis. Soil Cr thresholds for phytotoxicity meanwhile ensuring food safety were then derived on the condition of 10 percent yield reduction. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Microbial production of scleroglucan and downstream processing

    PubMed Central

    Castillo, Natalia A.; Valdez, Alejandra L.; Fariña, Julia I.

    2015-01-01

    Synthetic petroleum-based polymers and natural plant polymers have the disadvantage of restricted sources, in addition to the non-biodegradability of the former ones. In contrast, eco-sustainable microbial polysaccharides, of low-cost and standardized production, represent an alternative to address this situation. With a strong global market, they attracted worldwide attention because of their novel and unique physico-chemical properties as well as varied industrial applications, and many of them are promptly becoming economically competitive. Scleroglucan, a β-1,3-β-1,6-glucan secreted by Sclerotium fungi, exhibits high potential for commercialization and may show different branching frequency, side-chain length, and/or molecular weight depending on the producing strain or culture conditions. Water-solubility, viscosifying ability and wide stability over temperature, pH and salinity make scleroglucan useful for different biotechnological (enhanced oil recovery, food additives, drug delivery, cosmetic and pharmaceutical products, biocompatible materials, etc.), and biomedical (immunoceutical, antitumor, etc.) applications. It can be copiously produced at bioreactor scale under standardized conditions, where a high exopolysaccharide concentration normally governs the process optimization. Operative and nutritional conditions, as well as the incidence of scleroglucan downstream processing will be discussed in this chapter. The relevance of using standardized inocula from selected strains and experiences concerning the intricate scleroglucan scaling-up will be also herein outlined. PMID:26528259

  12. Active-learning diabetes simulation in an advanced pharmacy practice experience to develop patient empathy.

    PubMed

    Whitley, Heather P

    2012-12-12

    To develop and integrate an active-learning diabetes simulation into an advanced pharmacy practice experience to improve pharmacy students' empathy toward patients with diabetes mellitus. Students simulated the experience of having diabetes mellitus by conducting activities commonly prescribed to those with this disease state for 7 days, after which they submitted a standardized diabetes log and narrative reflection. Interpretive phenomenology design with thematic analysis was used to determine the impact of this experience on the students. As shown in student reflections, 95% developed empathy, 97% found the experience beneficial, and 67% improved their ability to relate to and counsel patients. Most (95%) found difficulty adhering to the regimen. On average, students consumed 179 grams of carbohydrates per day and exercised 5 days or 215 minutes per week. Additionally, 69% decided to modify their personal habits to become healthier. Inclusion of the 7-day active-learning exercise greatly impacted student pharmacists' self-reported empathy toward and ability to relate to patients with diabetes mellitus. Completion of this experience may result in long-lasting personal behavior modifications.

  13. g-LIMIT Status Briefing

    NASA Technical Reports Server (NTRS)

    Whorton, Mark; Perkins, Brad T.

    2000-01-01

    For many microgravity science experiments in the International Space Station, the ambient acceleration environment will be exceed desirable levels. To provide a more quiescent acceleration environment to the microgravity payloads, a vibration isolation system named g-LIMIT (GLovebox Integrated Microgravity Isolation Technology) is being designed. g-LIMIT is a sub-rack level isolation system that can be tailored to a variety of applications. Scheduled for launch on the UF-1 mission, the initial implementation of g-LIMIT will be a Characterization Test in the Microgravity Science Glovebox (MSG). g-LIMIT will be available to glovebox investigators immediately after characterization testing. Standard MSG structural and umbilical interfaces will be used so that the isolation mount is transparent to the user with no additional accommodation requirements. g-LIMIT consists of three integrated isolator modules, each of which is comprised of a dual axis actuator, two axes of acceleration sensing, two axes of position sensing, control electronics, and data transmission capabilities in a minimum-volume package. In addition, this system provides the unique capability for measuring absolute acceleration of the experiment independent of accelerometers as a by-product of the control system and will have the capability of generating pristine accelerations to enhance experiment operations.

  14. Prior experiences associated with residents' scores on a communication and interpersonal skill OSCE.

    PubMed

    Yudkowsky, Rachel; Downing, Steven M; Ommert, Dennis

    2006-09-01

    This exploratory study investigated whether prior task experience and comfort correlate with scores on an assessment of patient-centered communication. A six-station standardized patient exam assessed patient-centered communication of 79 PGY2-3 residents in Internal Medicine and Family Medicine. A survey provided information on prior experiences. t-tests, correlations, and multi-factorial ANOVA explored relationship between scores and experiences. Experience with a task predicted comfort but did not predict communication scores. Comfort was moderately correlated with communication scores for some tasks; residents who were less comfortable were indeed less skilled, but greater comfort did not predict higher scores. Female gender and medical school experiences with standardized patients along with training in patient-centered interviewing were associated with higher scores. Residents without standardized patient experiences in medical school were almost five times more likely to be rejected by patients. Task experience alone does not guarantee better communication, and may instill a false sense of confidence. Experiences with standardized patients during medical school, especially in combination with interviewing courses, may provide an element of "deliberate practice" and have a long-term impact on communication skills. The combination of didactic courses and practice with standardized patients may promote a patient-centered approach.

  15. How Do Pharmacists Develop into Advanced Level Practitioners? Learning from the Experiences of Critical Care Pharmacists.

    PubMed

    Seneviratne, Ruth E; Bradbury, Helen; Bourne, Richard S

    2017-07-07

    The national UK standards for critical care highlight the need for clinical pharmacists to practise at an advanced level (equivalent to Royal Pharmaceutical Society, Great Britain, Faculty Advanced Stage II (MFRPSII)) and above. Currently the UK is unable to meet the workforce capacity requirements set out in the national standards in terms of numbers of pharmacist working at advanced level and above. The aim of this study was to identify the strategies, barriers and challenges to achieving Advanced Level Practice (ALP) by learning from the experiences of advanced level critical care pharmacists within the UK. Eight participants were recruited to complete semi-structured interviews on their views and experiences of ALP. The interviews were analysed thematically and three overarching themes were identified; support, work-based learning and reflective practice. The results of this study highlight that to increase the number of MFRPSII level practitioners within critical care support for their ALP development is required. This support involves developing face-to-face access to expert critical care pharmacists within a national training programme. Additionally, chief pharmacists need to implement drivers including in house mentorship and peer review programmes and the need to align job descriptions and appraisals to the Royal Pharmaceutical Society, Great Britain, Advanced Practice Framework (APF).

  16. How Do Pharmacists Develop into Advanced Level Practitioners? Learning from the Experiences of Critical Care Pharmacists

    PubMed Central

    Seneviratne, Ruth E.; Bradbury, Helen

    2017-01-01

    The national UK standards for critical care highlight the need for clinical pharmacists to practise at an advanced level (equivalent to Royal Pharmaceutical Society, Great Britain, Faculty Advanced Stage II (MFRPSII)) and above. Currently the UK is unable to meet the workforce capacity requirements set out in the national standards in terms of numbers of pharmacist working at advanced level and above. The aim of this study was to identify the strategies, barriers and challenges to achieving Advanced Level Practice (ALP) by learning from the experiences of advanced level critical care pharmacists within the UK. Eight participants were recruited to complete semi-structured interviews on their views and experiences of ALP. The interviews were analysed thematically and three overarching themes were identified; support, work-based learning and reflective practice. The results of this study highlight that to increase the number of MFRPSII level practitioners within critical care support for their ALP development is required. This support involves developing face-to-face access to expert critical care pharmacists within a national training programme. Additionally, chief pharmacists need to implement drivers including in house mentorship and peer review programmes and the need to align job descriptions and appraisals to the Royal Pharmaceutical Society, Great Britain, Advanced Practice Framework (APF). PMID:28970450

  17. The influence of thermal discomfort on the attention index of teenagers: an experimental evaluation

    NASA Astrophysics Data System (ADS)

    Mazon, Jordi

    2014-07-01

    In order to measure the effect on the attention of teenagers of thermal discomfort due to high temperature and humidity, two experiments were conducted in two different indoor conditions of temperature and humidity in non-air-conditioned classrooms. The participants were a heterogeneous group of 117 teenagers, aged 12 to 18 years, and the experiments reproduced the actual conditions of teaching in a classroom in the Mediterranean climate. In order to measure the attention index, a standard Toulouse-Pieron psychological test was performed on the 117 teenagers in these two conditions, and the Predicted Mean Vote (PMV), the physiologically Equivalent Temperature (PET), the Standard effective Temperature (SET*) and the Universal Thermal Climate Index (UTCI) indices were calculated to estimate the grade of discomfort using the RayMan Pro model. Conditions of greater discomfort decreased the attention index in the whole group, especially in those aged 12-14, among whom the attention index dropped by around 45 % when compared to comfortable conditions. However, teenage attention at ages 17 and 18 shows little variation in discomfort in respect to thermally comfortable conditions. In addition, the attention index for boys and girls shows the same variation in discomfort conditions. However, girls have a slightly higher attention index than boys in discomfort and thermal comfort experiments.

  18. Web-based objective structured clinical examination with remote standardized patients and Skype: resident experience.

    PubMed

    Langenau, Erik; Kachur, Elizabeth; Horber, Dot

    2014-07-01

    Using Skype and remote standardized patients (RSPs), investigators sought to evaluate user acceptance of a web-based objective structured clinical examination (OSCE) among resident physicians. After participating in four web-based clinical encounters addressing pain with RSPs, 59 residents from different training programs, disciplines and geographic locations completed a 52-item questionnaire regarding their experience with Skype and RSPs. Open-ended responses were solicited as well. The majority of participants (97%) agreed or strongly agreed the web-based format was convenient and a practical learning exercise, and 90% agreed or strongly agreed the format was effective in teaching communication skills. Although 93% agreed or strongly agreed they could communicate easily with RSPs using Skype, 80% preferred traditional face-to-face clinical encounters, and 58% reported technical difficulties during the encounters. Open-ended written responses supported survey results. Findings from this study expose challenges with technology and human factors, but positive experiences support the continued investigation of web-based OSCEs as a synchronous e-learning initiative for teaching and assessing doctor-patient communication. Such educational programs are valuable but unlikely to replace face-to-face encounters with patients. This web-based OSCE program provides physician learners with additional opportunity to improve doctor-patient communication. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Standardization of 63Ni by 4πβ Liquid Scintillation Spectrometry With 3H-Standard Efficiency Tracing

    PubMed Central

    Zimmerman, B. E.; Collé, R.

    1997-01-01

    The low energy (Eβmax = 66.945 keV ± 0.004 keV) β-emitter 63Ni has become increasingly important in the field of radionuclidic metrology. In addition to having a low β-endpoint energy, the relatively long half-life (101.1 a ± 1.4 a) makes it an appealing standard for such applications. This paper describes the recent preparation and calibration of a new solution Standard Reference Material of 63Ni, SRM 4226C, released by the National Institute of Standards and Technology. The massic activity CA for these standards was determined using 4πβ liquid scintillation (LS) spectrometry with 3H-standard efficiency tracing using the CIEMAT/NIST method, and is certified as 50.53 kBq ·g−1 ± 0.46 Bq · g−1 at the reference time of 1200 EST August 15, 1995. The uncertainty given is the expanded (coverage factor k = 2 and thus a 2 standard deviation estimate) uncertainty based on the evaluation of 28 different uncertainty components. These components were evaluated on the basis of an exhaustive number (976) of LS counting measurements investigating over 15 variables. Through the study of these variables it was found that LS cocktail water mass fraction and ion concentration play important roles in cocktail stability and consistency of counting results. The results of all of these experiments are discussed. PMID:27805155

  20. A Database of Herbaceous Vegetation Responses to Elevated Atmospheric CO2 (NDP-073)

    DOE Data Explorer

    Jones, Michael H [The Ohio State Univ., Columbus, OH (United States); Curtis, Peter S [The Ohio State Univ., Columbus, OH (United States); Cushman, Robert M [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Brenkert, Antoinette L [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    1999-01-01

    To perform a statistically rigorous meta-analysis of research results on the response by herbaceous vegetation to increased atmospheric CO2 levels, a multiparameter database of responses was compiled from the published literature. Seventy-eight independent CO2-enrichment studies, covering 53 species and 26 response parameters, reported mean response, sample size, and variance of the response (either as standard deviation or standard error). An additional 43 studies, covering 25 species and 6 response parameters, did not report variances. This numeric data package accompanies the Carbon Dioxide Information Analysis Center's (CDIAC's) NDP- 072, which provides similar information for woody vegetation. This numeric data package contains a 30-field data set of CO2- exposure experiment responses by herbaceous plants (as both a flat ASCII file and a spreadsheet file), files listing the references to the CO2-exposure experiments and specific comments relevant to the data in the data sets, and this documentation file (which includes SAS and Fortran codes to read the ASCII data file; SAS is a registered trademark of the SAS Institute, Inc., Cary, North Carolina 27511).

  1. The Costs and Benefits of Compliance with Renewable Portfolio Standards: Reviewing Experience to Date

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, Jenny; Barbose, Galen; Bird, Lori

    2014-03-12

    More than half of U.S. states have renewable portfolio standards (RPS) in place and have collectively deployed approximately 46,000 MW of new renewable energy capacity through year-end 2012. Most of these policies have five or more years of implementation experience, enabling an assessment of their costs and benefits. Understanding RPS benefits and costs is essential for policymakers evaluating existing RPS policies, assessing the need for modifications, and considering new policies. A key aspect of this study is the comprehensive review of existing RPS cost and benefit estimates, in addition to an examination of the variety of methods used to calculatemore » such estimates. Based on available data and estimates reported by utilities and regulators, this study summarizes RPS costs to date. The study considers how those costs may evolve going forward, given scheduled increases in RPS targets and cost containment mechanisms incorporated into existing policies. The report also summarizes RPS benefits estimates, based on published studies for individual states, and discusses key methodological considerations.« less

  2. Quantitative Proteomics via High Resolution MS Quantification: Capabilities and Limitations

    PubMed Central

    Higgs, Richard E.; Butler, Jon P.; Han, Bomie; Knierman, Michael D.

    2013-01-01

    Recent improvements in the mass accuracy and resolution of mass spectrometers have led to renewed interest in label-free quantification using data from the primary mass spectrum (MS1) acquired from data-dependent proteomics experiments. The capacity for higher specificity quantification of peptides from samples enriched for proteins of biological interest offers distinct advantages for hypothesis generating experiments relative to immunoassay detection methods or prespecified peptide ions measured by multiple reaction monitoring (MRM) approaches. Here we describe an evaluation of different methods to post-process peptide level quantification information to support protein level inference. We characterize the methods by examining their ability to recover a known dilution of a standard protein in background matrices of varying complexity. Additionally, the MS1 quantification results are compared to a standard, targeted, MRM approach on the same samples under equivalent instrument conditions. We show the existence of multiple peptides with MS1 quantification sensitivity similar to the best MRM peptides for each of the background matrices studied. Based on these results we provide recommendations on preferred approaches to leveraging quantitative measurements of multiple peptides to improve protein level inference. PMID:23710359

  3. Efforts to integrate CMIP metadata and standards into NOAA-GFDL's climate model workflow

    NASA Astrophysics Data System (ADS)

    Blanton, C.; Lee, M.; Mason, E. E.; Radhakrishnan, A.

    2017-12-01

    Modeling centers participating in CMIP6 run model simulations, publish requested model output (conforming to community data standards), and document models and simulations using ES-DOC. GFDL developed workflow software implementing some best practices to meet these metadata and documentation requirements. The CMIP6 Data Request defines the variables that should be archived for each experiment and specifies their spatial and temporal structure. We used the Data Request's dreqPy python library to write GFDL model configuration files as an alternative to hand-crafted tables. There was also a largely successful effort to standardize variable names within the model to reduce the additional overhead of translating "GFDL to CMOR" variables at a later stage in the pipeline. The ES-DOC ecosystem provides tools and standards to create, publish, and view various types of community-defined CIM documents, most notably model and simulation documents. Although ES-DOC will automatically create simulation documents during publishing by harvesting NetCDF global attributes, the information must be collected, stored, and placed in the NetCDF files by the workflow. We propose to develop a GUI to collect the simulation document precursors. In addition, a new MIP for CMIP6-CPMIP, a comparison of computational performance of climate models-is documented using machine and performance CIM documents. We used ES-DOC's pyesdoc python library to automatically create these machine and performance documents. We hope that these and similar efforts will become permanent features of the GFDL workflow to facilitate future participation in CMIP-like activities.

  4. Review of Real-Time 3-Dimensional Image Guided Radiation Therapy on Standard-Equipped Cancer Radiation Therapy Systems: Are We at the Tipping Point for the Era of Real-Time Radiation Therapy?

    PubMed

    Keall, Paul J; Nguyen, Doan Trang; O'Brien, Ricky; Zhang, Pengpeng; Happersett, Laura; Bertholet, Jenny; Poulsen, Per R

    2018-04-14

    To review real-time 3-dimensional (3D) image guided radiation therapy (IGRT) on standard-equipped cancer radiation therapy systems, focusing on clinically implemented solutions. Three groups in 3 continents have clinically implemented novel real-time 3D IGRT solutions on standard-equipped linear accelerators. These technologies encompass kilovoltage, combined megavoltage-kilovoltage, and combined kilovoltage-optical imaging. The cancer sites treated span pelvic and abdominal tumors for which respiratory motion is present. For each method the 3D-measured motion during treatment is reported. After treatment, dose reconstruction was used to assess the treatment quality in the presence of motion with and without real-time 3D IGRT. The geometric accuracy was quantified through phantom experiments. A literature search was conducted to identify additional real-time 3D IGRT methods that could be clinically implemented in the near future. The real-time 3D IGRT methods were successfully clinically implemented and have been used to treat more than 200 patients. Systematic target position shifts were observed using all 3 methods. Dose reconstruction demonstrated that the delivered dose is closer to the planned dose with real-time 3D IGRT than without real-time 3D IGRT. In addition, compromised target dose coverage and variable normal tissue doses were found without real-time 3D IGRT. The geometric accuracy results with real-time 3D IGRT had a mean error of <0.5 mm and a standard deviation of <1.1 mm. Numerous additional articles exist that describe real-time 3D IGRT methods using standard-equipped radiation therapy systems that could also be clinically implemented. Multiple clinical implementations of real-time 3D IGRT on standard-equipped cancer radiation therapy systems have been demonstrated. Many more approaches that could be implemented were identified. These solutions provide a pathway for the broader adoption of methods to make radiation therapy more accurate, impacting tumor and normal tissue dose, margins, and ultimately patient outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. 21 CFR 130.20 - Food additives proposed for use in foods for which definitions and standards of identity are...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 2 2013-04-01 2013-04-01 false Food additives proposed for use in foods for which...: GENERAL Food Additives in Standardized Foods § 130.20 Food additives proposed for use in foods for which... the act, which proposes the inclusion of a food additive in such definition and standard of identity...

  6. 21 CFR 130.20 - Food additives proposed for use in foods for which definitions and standards of identity are...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Food additives proposed for use in foods for which...: GENERAL Food Additives in Standardized Foods § 130.20 Food additives proposed for use in foods for which... the act, which proposes the inclusion of a food additive in such definition and standard of identity...

  7. 21 CFR 130.20 - Food additives proposed for use in foods for which definitions and standards of identity are...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Food additives proposed for use in foods for which...: GENERAL Food Additives in Standardized Foods § 130.20 Food additives proposed for use in foods for which... the act, which proposes the inclusion of a food additive in such definition and standard of identity...

  8. 21 CFR 130.20 - Food additives proposed for use in foods for which definitions and standards of identity are...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 2 2011-04-01 2011-04-01 false Food additives proposed for use in foods for which...: GENERAL Food Additives in Standardized Foods § 130.20 Food additives proposed for use in foods for which... the act, which proposes the inclusion of a food additive in such definition and standard of identity...

  9. 21 CFR 130.20 - Food additives proposed for use in foods for which definitions and standards of identity are...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false Food additives proposed for use in foods for which...: GENERAL Food Additives in Standardized Foods § 130.20 Food additives proposed for use in foods for which... the act, which proposes the inclusion of a food additive in such definition and standard of identity...

  10. qcML: An Exchange Format for Quality Control Metrics from Mass Spectrometry Experiments*

    PubMed Central

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W. P.; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A.; Kelstrup, Christian D.; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S.; Olsen, Jesper V.; Heck, Albert J. R.; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-01-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. PMID:24760958

  11. qcML: an exchange format for quality control metrics from mass spectrometry experiments.

    PubMed

    Walzer, Mathias; Pernas, Lucia Espona; Nasso, Sara; Bittremieux, Wout; Nahnsen, Sven; Kelchtermans, Pieter; Pichler, Peter; van den Toorn, Henk W P; Staes, An; Vandenbussche, Jonathan; Mazanek, Michael; Taus, Thomas; Scheltema, Richard A; Kelstrup, Christian D; Gatto, Laurent; van Breukelen, Bas; Aiche, Stephan; Valkenborg, Dirk; Laukens, Kris; Lilley, Kathryn S; Olsen, Jesper V; Heck, Albert J R; Mechtler, Karl; Aebersold, Ruedi; Gevaert, Kris; Vizcaíno, Juan Antonio; Hermjakob, Henning; Kohlbacher, Oliver; Martens, Lennart

    2014-08-01

    Quality control is increasingly recognized as a crucial aspect of mass spectrometry based proteomics. Several recent papers discuss relevant parameters for quality control and present applications to extract these from the instrumental raw data. What has been missing, however, is a standard data exchange format for reporting these performance metrics. We therefore developed the qcML format, an XML-based standard that follows the design principles of the related mzML, mzIdentML, mzQuantML, and TraML standards from the HUPO-PSI (Proteomics Standards Initiative). In addition to the XML format, we also provide tools for the calculation of a wide range of quality metrics as well as a database format and interconversion tools, so that existing LIMS systems can easily add relational storage of the quality control data to their existing schema. We here describe the qcML specification, along with possible use cases and an illustrative example of the subsequent analysis possibilities. All information about qcML is available at http://code.google.com/p/qcml. © 2014 by The American Society for Biochemistry and Molecular Biology, Inc.

  12. Radiometric calibration of optical microscopy and microspectroscopy apparata over a broad spectral range using a special thin-film luminescence standard

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Valenta, J., E-mail: jan.valenta@mff.cuni.cz; Greben, M.

    2015-04-15

    Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized bymore » separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.« less

  13. An oral health intervention for people with serious mental illness (Three Shires Early Intervention Dental Trial): study protocol for a randomised controlled trial.

    PubMed

    Jones, Hannah F; Adams, Clive E; Clifton, Andrew; Simpson, Jayne; Tosh, Graeme; Liddle, Peter F; Callaghan, Patrick; Yang, Min; Guo, Boliang; Furtado, Vivek

    2013-05-29

    Oral health is an important part of general physical health and is essential for self-esteem, self-confidence and overall quality of life. There is a well-established link between mental illness and poor oral health. Oral health problems are not generally well recognized by mental health professionals and many patients experience barriers to treatment. This is the protocol for a pragmatic cluster randomised trial that has been designed to fit within standard care. Dental awareness training for care co-ordinators plus a dental checklist for service users in addition to standard care will be compared with standard care alone for people with mental illness. The checklist consists of questions about service users' current oral health routine and condition. Ten Early Intervention in Psychosis (EIP) teams in Nottinghamshire, Derbyshire and Lincolnshire will be cluster randomised (five to intervention and five to standard care) in blocks accounting for location and size of caseload. The oral health of the service users will be monitored for one year after randomisation. Current Controlled Trials ISRCTN63382258.

  14. 45 CFR 156.285 - Additional standards specific to SHOP.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 156.285 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE ISSUER STANDARDS UNDER THE AFFORDABLE CARE ACT, INCLUDING STANDARDS RELATED TO EXCHANGES Qualified Health Plan Minimum Certification Standards § 156.285 Additional standards...

  15. 45 CFR 156.285 - Additional standards specific to SHOP.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 156.285 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES REQUIREMENTS RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE ISSUER STANDARDS UNDER THE AFFORDABLE CARE ACT, INCLUDING STANDARDS RELATED TO EXCHANGES Qualified Health Plan Minimum Certification Standards § 156.285 Additional standards...

  16. 45 CFR 156.285 - Additional standards specific to SHOP.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 156.285 Public Welfare Department of Health and Human Services REQUIREMENTS RELATING TO HEALTH CARE ACCESS HEALTH INSURANCE ISSUER STANDARDS UNDER THE AFFORDABLE CARE ACT, INCLUDING STANDARDS RELATED TO EXCHANGES Qualified Health Plan Minimum Certification Standards § 156.285 Additional standards...

  17. Answering Gauguin’s Questions: Where Are We Coming From, Where Are We Going, and What Are We?

    ScienceCinema

    Ellis, John [CERN

    2017-12-09

    The knowledge of matter revealed by the current reigning theory of particle physics, the so-called Standard Model, still leaves open many basic questions. What is the origin of the matter in the Universe? How does its mass originate? What is the nature of the dark matter that fills the Universe? Are there additional dimensions of space? The Large Hadron Collider (LHC) at the CERN Laboratory in Geneva, Switzerland, where high-energy experiments have now started, will take physics into a new realm of energy and time, and will address these physics analogues of Gauguin's questions. The answers will set the stage for possible future experiments beyond the scope of the LHC.

  18. Mitral Transcatheter Technologies

    PubMed Central

    Maisano, Francesco; Buzzatti, Nicola; Taramasso, Maurizio; Alfieri, Ottavio

    2013-01-01

    Mitral valve regurgitation (MR) is often diagnosed in patients with heart failure and is associated with worsening of symptoms and reduced survival. While surgery remains the gold standard treatment in low-risk patients with degenerative MR, in high-risk patients and in those with functional MR, transcatheter procedures are emerging as an alternative therapeutic option. MitraClip® is the device with which the largest clinical experience has been gained to date, as it offers sustained clinical benefit in selected patients. Further to MitraClip implantation, several additional approaches are developing, to better match with the extreme variability of mitral valve disease. Not only repair is evolving, initial steps towards percutaneous mitral valve implantation have already been undertaken, and initial clinical experience has just started. PMID:23908865

  19. Inclusive and differential measurements of the $$\\mathrm{ t \\bar{t} }$$ charge asymmetry in pp collisions at $$\\sqrt{s} =$$ 8 TeV

    DOE PAGES

    Khachatryan, Vardan

    2016-03-29

    The tt charge asymmetry is measured in proton-proton collisions at a centre-of-mass energy of 8 TeV. The data, collected with the CMS experiment at the LHC, correspond to an integrated luminosity of 19.7 fb -1 . Selected events contain an electron or a muon and four or more jets, where at least one jet is identified as originating from b-quark hadronization. The inclusive charge asymmetry is found to be 0.0010 ± 0.0068 (stat) ± 0.0037 (syst). In addition, differential charge asymmetries as a function of rapidity, transverse momentum, and invariant mass of the tt system are studied. For the firstmore » time at the LHC, our measurements are also performed in a reduced fiducial phase space of top quark pair production, with an integrated result of -0.0035 ± 0.0072 (stat) ± 0.0031 (syst). Additionally, all measurements are consistent within two standard deviations with zero asymmetry as well as with the predictions of the standard model.« less

  20. Gamma-rays from dark showers with twin Higgs models

    NASA Astrophysics Data System (ADS)

    Freytsis, Marat; Knapen, Simon; Robinson, Dean J.; Tsai, Yuhsin

    2016-05-01

    We consider a twin WIMP scenario whose twin sector contains a full dark copy of the SM hadrons, where the lightest twin particles are twin pions. By analogy to the standard WIMP paradigm, the dark matter (DM) freezes out through twin electroweak interactions, and annihilates into a dark shower of light twin hadrons. These are either stable or decay predominantly to standard model (SM) photons. We show that this `hadrosymmetric' scenario can be consistent with all applicable astrophysical, cosmological and collider constraints. In order to decay the twin hadrons before the big-bang nucleosynthesis epoch, an additional portal between the SM and twin sector is required. In most cases we find this additional mediator is within reach of either the LHC or future intensity frontier experiments. Furthermore, we conduct simulations of the dark shower and consequent photon spectra. We find that fits of these spectra to the claimed galactic center gamma-ray excess seen by Fermi -LAT non-trivially coincide with regions of parameter space that both successfully generate the observed DM abundance and exhibit minimal fine-tuning.

  1. Gamma-rays from dark showers with twin Higgs models

    DOE PAGES

    Freytsis, Marat; Knapen, Simon; Robinson, Dean J.; ...

    2016-05-03

    We consider a twin WIMP scenario whose twin sector contains a full dark copy of the SM hadrons, where the lightest twin particles are twin pions. By analogy to the standard WIMP paradigm, the dark matter (DM) freezes out through twin electroweak interactions, and annihilates into a dark shower of light twin hadrons. These are either stable or decay predominantly to standard model (SM) photons. We show that this ‘hadrosymmetric’ scenario can be consistent with all applicable astrophysical, cosmological and collider constraints. In order to decay the twin hadrons before the big-bang nucleosynthesis epoch, an additional portal between the SMmore » and twin sector is required. In most cases we find this additional mediator is within reach of either the LHC or future intensity frontier experiments. Furthermore, we conduct simulations of the dark shower and consequent photon spectra. We find that fits of these spectra to the claimed galactic center gamma-ray excess seen by Fermi -LAT non-trivially coincide with regions of parameter space that both successfully generate the observed DM abundance and exhibit minimal fine-tuning.« less

  2. Analytical challenges in drug counterfeiting and falsification-The NMR approach.

    PubMed

    Holzgrabe, Ulrike; Malet-Martino, Myriam

    2011-06-25

    Counterfeiting of products is a global problem. As long as clothes, clocks, leather wear, etc. are faked there is no danger, but when it comes to drugs, counterfeiting can be life-threatening. In the last years sub-standard active pharmaceutical ingredients (APIs) were found more often even though the use of the quality-ensuring methods of international pharmacopoeias should have detected additional impurities and the low content of the API. Methods orthogonal to the separating methods used in the pharmacopoeias are necessary to find counterfeits. Beside Raman and NIR spectroscopies as well as powder X-ray analysis, NMR spectroscopy being a primary ratio method of measurement is highly suitable to identify and quantify a drug and its related substances as well as to recognize a drug of sub-standard quality. DOSY experiments are suitable to identify the ingredients of formulations and therefore to identify wrong and/or additional ingredients. This review gives an overview of the application of quantitative NMR spectroscopy and DOSY NMR in anticounterfeiting. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Effective field theory of integrating out sfermions in the MSSM: Complete one-loop analysis

    NASA Astrophysics Data System (ADS)

    Huo, Ran

    2018-04-01

    We apply the covariant derivative expansion of the Coleman-Weinberg potential to the sfermion sector in the minimal supersymmetric standard model, matching it to the relevant dimension-6 operators in the standard model effective field theory at one-loop level. Emphasis is paid to nondegenerate large soft supersymmetry breaking mass squares, and the most general analytical Wilson coefficients are obtained for all pure bosonic dimension-6 operators. In addition to the non-logarithmic contributions, they generally have another logarithmic contributions. Various numerical results are shown, in particular the constraints in the large Xt branch reproducing the 125 GeV Higgs mass can be pushed to high values to almost completely probe the low stop mass region at the future FCC-ee experiment, even given the Higgs mass calculation uncertainty.

  4. Particle physics today, tomorrow and beyond

    NASA Astrophysics Data System (ADS)

    Ellis, John

    2018-01-01

    The most important discovery in particle physics in recent years was that of the Higgs boson, and much effort is continuing to measure its properties, which agree obstinately with the Standard Model, so far. However, there are many reasons to expect physics beyond the Standard Model, motivated by the stability of the electroweak vacuum, the existence of dark matter and the origin of the visible matter in the Universe, neutrino physics, the hierarchy of mass scales in physics, cosmological inflation and the need for a quantum theory for gravity. Most of these issues are being addressed by the experiments during Run 2 of the LHC, and supersymmetry could help resolve many of them. In addition to the prospects for the LHC, I also review briefly those for direct searches for dark matter and possible future colliders.

  5. Resistance to extinction of human evaluative conditioning using a between-subjects design.

    PubMed

    Baeyens, F; Díaz, E; Ruiz, G

    2005-02-01

    Two experiments were conducted to examine whether the resistance to extinction obtained in evaluative conditioning (EC) studies implies that EC is a qualitatively distinct form of classical conditioning (Baeyens, Eelen, & Crombez, 1995 a) or whether it is the result of an nonassociative artefact ( Field & Davey, 1997 , 1998 , 1999 ). Both experiments included between-subjects control groups in addition to standard within-subjects control conditions. In Experiment 1, only verbal ratings were measured in order to evaluate the effect of postacquisition CS-only exposures on EC whereas in Experiment 2, verbal ratings and postextinction priming effects were measured. The results showed that the EC effects are demonstrable in a between-subjects design and that the extinction procedure did not have any influence on the acquired evaluative value of CSs regardless of whether the verbal ratings or the priming effects were used as dependent variables. The present results provide evidence that EC is resistant to extinction and suggest an interpretation of EC as a qualitatively distinct form of associative learning.

  6. Understanding Male Underachievement in Middle School Science: Challenging the Assumptions

    NASA Astrophysics Data System (ADS)

    Holbrooks, Marilyn Jane

    The overall purpose of this collaborative action research study was to explore the experiences of eight middle school science teachers. This collaborative action research study concerned itself with male student underachievement in science at the middle school level. The study was conducted at Sherwood Forest Middle School (a pseudonym) with sixth through eighth grade science teachers with more than three years of experience, various teaching backgrounds within academic subjects as well as special education, and different grade levels. The interviews probed the teachers' personal experiences and insights regarding male underachievement in science. This collaborative action research study relied on qualitative data from interviews and other pieces of evidence that might support the teachers' observations, specifically standardized test data and class grades. In addition, four of the seven teachers participated in a focus group, developing strategies for more effective teaching in science for all students. Understanding the experiences of science educators for sixth through eighth grade students can assist local, state, and federal policymakers in educational decision-making processes for the future.

  7. Astrophysical particle acceleration mechanisms in colliding magnetized laser-produced plasmas

    DOE PAGES

    Fox, W.; Park, J.; Deng, W.; ...

    2017-08-11

    Significant particle energization is observed to occur in numerous astrophysical environments, and in the standard models, this acceleration occurs alongside energy conversion processes including collisionless shocks or magnetic reconnection. Recent platforms for laboratory experiments using magnetized laser-produced plasmas have opened opportunities to study these particle acceleration processes in the laboratory. Through fully kinetic particle-in-cell simulations, we investigate acceleration mechanisms in experiments with colliding magnetized laser-produced plasmas, with geometry and parameters matched to recent high-Mach number reconnection experiments with externally controlled magnetic fields. 2-D simulations demonstrate significant particle acceleration with three phases of energization: first, a “direct” Fermi acceleration driven bymore » approaching magnetized plumes; second, x-line acceleration during magnetic reconnection of anti-parallel fields; and finally, an additional Fermi energization of particles trapped in contracting and relaxing magnetic islands produced by reconnection. Furthermore, the relative effectiveness of these mechanisms depends on plasma and magnetic field parameters of the experiments.« less

  8. Is overall similarity classification less effortful than single-dimension classification?

    PubMed

    Wills, Andy J; Milton, Fraser; Longmore, Christopher A; Hester, Sarah; Robinson, Jo

    2013-01-01

    It is sometimes argued that the implementation of an overall similarity classification is less effortful than the implementation of a single-dimension classification. In the current article, we argue that the evidence securely in support of this view is limited, and report additional evidence in support of the opposite proposition--overall similarity classification is more effortful than single-dimension classification. Using a match-to-standards procedure, Experiments 1A, 1B and 2 demonstrate that concurrent load reduces the prevalence of overall similarity classification, and that this effect is robust to changes in the concurrent load task employed, the level of time pressure experienced, and the short-term memory requirements of the classification task. Experiment 3 demonstrates that participants who produced overall similarity classifications from the outset have larger working memory capacities than those who produced single-dimension classifications initially, and Experiment 4 demonstrates that instructions to respond meticulously increase the prevalence of overall similarity classification.

  9. Structural verification for GAS experiments

    NASA Technical Reports Server (NTRS)

    Peden, Mark Daniel

    1992-01-01

    The purpose of this paper is to assist the Get Away Special (GAS) experimenter in conducting a thorough structural verification of its experiment structural configuration, thus expediting the structural review/approval process and the safety process in general. Material selection for structural subsystems will be covered with an emphasis on fasteners (GSFC fastener integrity requirements) and primary support structures (Stress Corrosion Cracking requirements and National Space Transportation System (NSTS) requirements). Different approaches to structural verifications (tests and analyses) will be outlined especially those stemming from lessons learned on load and fundamental frequency verification. In addition, fracture control will be covered for those payloads that utilize a door assembly or modify the containment provided by the standard GAS Experiment Mounting Plate (EMP). Structural hazard assessment and the preparation of structural hazard reports will be reviewed to form a summation of structural safety issues for inclusion in the safety data package.

  10. Relatively brief environmental enrichment aids recovery of learning capacity and alters brain measures after postweaning brain lesions in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Will, B.E.; Rosenzweig, M.R.; Bennett, E.L.

    1977-01-01

    Enriched postlesion experience aided in overcoming effects of simultaneous bilateral cerebral lesions made at 30 days of age in one experiment with inbred Fischer rats and in a second experiment with the Berkeley S/sub 1/ strain. The lesions were directed to the occipital cortex, but in most cases there was also some impairment of the hippocampus. For 60 days after operations, half of the rats lived in small individual cages and half lived in groups in large enriched-environment cages. They were then pretrained and tested on the standard 12 Hebb-Williams problems. Daily injections of methamphetamine (vs. saline) during the periodmore » of differential experience in the first experiment produced no effect on the behavioral scores. The second experiment included groups that received only 2 hr/day of enriched experience, and they benefited as much as groups that remained in the enriched environment 24 hr/day. The results of both experiments demonstrated significant beneficial effects of environment when bilateral lesions were made at a later age and when the periods of enriched experience were shorter than had previously been tested. Two additional experiments revealed significant effects of both lesions and environment on weight and RNA/DNA of brain regions.« less

  11. Technical note: unsafe rectal temperature measurements due to delayed warming of the thermocouple by using a condom. An issue concerning the estimation of the postmortem interval by using Henßge's nomogram.

    PubMed

    Krap, Tristan; Meurs, Joris; Boertjes, Janine; Duijst, Wilma

    2016-03-01

    In some cases, in the Netherlands, an additional layer is being added to the thermocouple, used to measure the rectal temperature in medicolegal death investigations. Because of this deviation from the standard method, questions arose regarding the accuracy and precision of the measured temperature. Therefore, a cooling experiment was carried out on a round body made of agar with an average thermal conductivity of 0.454 W/(m °C) while measuring the temperature with and without an additional layer around the thermocouple for three different starting temperatures: 36, 30, and 27 °C. The results show a significant difference between the measured values for the first 5 min when comparing with and without the additional layer. Further, a decrease in precision is present within the first minutes when using an additional layer. Therefore, it is concluded that it is best to measure the rectal temperature without an additional layer around the thermocouple and caution should be taken when measuring with an additional layer.

  12. A consistent model for leptogenesis, dark matter and the IceCube signal

    NASA Astrophysics Data System (ADS)

    Fiorentin, M. Re; Niro, V.; Fornengo, N.

    2016-11-01

    We discuss a left-right symmetric extension of the Standard Model in which the three additional right-handed neutrinos play a central role in explaining the baryon asymmetry of the Universe, the dark matter abundance and the ultra energetic signal detected by the IceCube experiment. The energy spectrum and neutrino flux measured by IceCube are ascribed to the decays of the lightest right-handed neutrino N 1, thus fixing its mass and lifetime, while the production of N 1 in the primordial thermal bath occurs via a freeze-in mechanism driven by the additional SU(2) R interactions. The constraints imposed by IceCube and the dark matter abundance allow nonetheless the heavier right-handed neutrinos to realize a standard type-I seesaw leptogenesis, with the B - L asymmetry dominantly produced by the next-to-lightest neutrino N 2. Further consequences and predictions of the model are that: the N 1 production implies a specific power-law relation between the reheating temperature of the Universe and the vacuum expectation value of the SU(2) R triplet; leptogenesis imposes a lower bound on the reheating temperature of the Universe at 7 × 109 GeV. Additionally, the model requires a vanishing absolute neutrino mass scale m 1 ≃ 0.

  13. New functional pavements for pedestrians and cyclists.

    PubMed

    Wallqvist, V; Kjell, G; Cupina, E; Kraft, L; Deck, C; Willinger, R

    2017-08-01

    When many fields of pedestrian and cyclist safety have been extensively studied, the surfacing has long been left unquestioned, despite being developed for another mode of transport and being one of the main causes for falls and fall injuries. In this project new surfacing materials for pedestrian and cyclist safety have been produced. Focusing on augmenting previously largely disregarded parameters as impact absorption, comfort and visibility at the same time as avoiding deteriorating of crucial parameters as friction and wear resistance. Rubber content, binder type, and pigment addition have been varied and evaluated. The results demonstrate that by increasing rubber content of the mixtures the head injury criterion (HIC) value and injury risk can be decreased while maintaining frictional properties according to existing criteria. Assembly of test-lanes demonstrate that some developed materials experience lower flow and component separation than standard materials due to rubber addition, calling for further optimisation of construction procedure linked to content development. Initial trials on the test-lanes indicate that a polyurethane (PU) based material has high cycling comfort, visibility and can be modified with phosphorescence properties. For standard asphalt, impact absorption might be inflicted by modification of bitumen alone but is mostly augmented by rubber addition. The results also indicate that rubber content can decrease ice formation on the materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Heritability of Individual Psychotic Experiences Captured by Common Genetic Variants in a Community Sample of Adolescents.

    PubMed

    Sieradzka, Dominika; Power, Robert A; Freeman, Daniel; Cardno, Alastair G; Dudbridge, Frank; Ronald, Angelica

    2015-09-01

    Occurrence of psychotic experiences is common amongst adolescents in the general population. Twin studies suggest that a third to a half of variance in adolescent psychotic experiences is explained by genetic influences. Here we test the extent to which common genetic variants account for some of the twin-based heritability. Psychotic experiences were assessed with the Specific Psychotic Experiences Questionnaire in a community sample of 2152 16-year-olds. Self-reported measures of Paranoia, Hallucinations, Cognitive Disorganization, Grandiosity, Anhedonia, and Parent-rated Negative Symptoms were obtained. Estimates of SNP heritability were derived and compared to the twin heritability estimates from the same sample. Three approaches to genome-wide restricted maximum likelihood (GREML) analyses were compared: (1) standard GREML performed on full genome-wide data; (2) GREML stratified by minor allele frequency (MAF); and (3) GREML performed on pruned data. The standard GREML revealed a significant SNP heritability of 20 % for Anhedonia (SE = 0.12; p < 0.046) and an estimate of 19 % for Cognitive Disorganization, which was close to significant (SE = 0.13; p < 0.059). Grandiosity and Paranoia showed modest SNP heritability estimates (17 %; SE = 0.13 and 14 %; SE = 0.13, respectively, both n.s.), and zero estimates were found for Hallucinations and Negative Symptoms. The estimates for Anhedonia, Cognitive Disorganization and Grandiosity accounted for approximately half the previously reported twin heritability. SNP heritability estimates from the MAF-stratified approach were mostly consistent with the standard estimates and offered additional information about the distribution of heritability across the MAF range of the SNPs. In contrast, the estimates derived from the pruned data were for the most part not consistent with the other two approaches. It is likely that the difference seen in the pruned estimates was driven by the loss of tagged causal variants, an issue fundamental to this approach. The current results suggest that common genetic variants play a role in the etiology of some adolescent psychotic experiences, however further research on larger samples is desired and the use of MAF-stratified approach recommended.

  15. An Additive Manufacturing Test Artifact

    PubMed Central

    Moylan, Shawn; Slotwinski, John; Cooke, April; Jurrens, Kevin; Donmez, M Alkan

    2014-01-01

    A test artifact, intended for standardization, is proposed for the purpose of evaluating the performance of additive manufacturing (AM) systems. A thorough analysis of previously proposed AM test artifacts as well as experience with machining test artifacts have inspired the design of the proposed test artifact. This new artifact is designed to provide a characterization of the capabilities and limitations of an AM system, as well as to allow system improvement by linking specific errors measured in the test artifact to specific sources in the AM system. The proposed test artifact has been built in multiple materials using multiple AM technologies. The results of several of the builds are discussed, demonstrating how the measurement results can be used to characterize and improve a specific AM system. PMID:26601039

  16. Planning the Unplanned Experiment: Assessing the Efficacy of Standards for Safety Critical Software

    NASA Technical Reports Server (NTRS)

    Graydon, Patrick J.; Holloway, C. Michael

    2015-01-01

    We need well-founded means of determining whether software is t for use in safety-critical applications. While software in industries such as aviation has an excellent safety record, the fact that software aws have contributed to deaths illustrates the need for justi ably high con dence in software. It is often argued that software is t for safety-critical use because it conforms to a standard for software in safety-critical systems. But little is known about whether such standards `work.' Reliance upon a standard without knowing whether it works is an experiment; without collecting data to assess the standard, this experiment is unplanned. This paper reports on a workshop intended to explore how standards could practicably be assessed. Planning the Unplanned Experiment: Assessing the Ecacy of Standards for Safety Critical Software (AESSCS) was held on 13 May 2014 in conjunction with the European Dependable Computing Conference (EDCC). We summarize and elaborate on the workshop's discussion of the topic, including both the presented positions and the dialogue that ensued.

  17. Broadband cavity enhanced spectroscopy in the ultraviolet spectral region for measurements of nitrogen dioxide and formaldehyde

    NASA Astrophysics Data System (ADS)

    Washenfelder, R. A.; Attwood, A. R.; Flores, J. M.; Rudich, Y.; Brown, S. S.

    2015-09-01

    Formaldehyde (CH2O) is the most abundant aldehyde in the atmosphere, and strongly affects photochemistry through its photolysis. We describe simultaneous measurements of CH2O and nitrogen dioxide (NO2) using broadband cavity enhanced spectroscopy in the ultraviolet spectral region. The light source consists of a continuous-wave diode laser focused into a Xenon bulb to produce a plasma that emits high-intensity, broadband light. The plasma discharge is optically filtered and coupled into a 1 m optical cavity. The reflectivity of the cavity mirrors is 0.99933 ± 0.00003 (670 ppm loss) at 338 nm, as determined from the known Rayleigh scattering of He and zero air. This mirror reflectivity corresponds to an effective path length of 1.49 km within the 1 m cell. We measure the cavity output over the 315-350 nm spectral region using a grating monochromator and charge-coupled device (CCD) array detector. We use published reference spectra with spectral fitting software to simultaneously retrieve CH2O and NO2 concentrations. Independent measurements of NO2 standard additions by broadband cavity enhanced spectroscopy and cavity ringdown spectroscopy agree within 2 % (slope for linear fit = 0.98 ± 0.03 with r2 = 0.998). Standard additions of CH2O measured by broadband cavity enhanced spectroscopy and calculated based on flow dilution are also well-correlated, with r2 = 0.9998. During constant, mixed additions of NO2 and CH2O, the 30 s measurement precisions (1σ) of the current configuration were 140 and 210 pptv, respectively. The current 1-min detection limit for extinction measurements at 315-350 nm provides sufficient sensitivity for measurement of trace gases in laboratory experiments and ground-based field experiments. Additionally, the instrument provides highly accurate, spectroscopically-based trace gas detection that may complement higher precision techniques based on non-absolute detection methods. In addition to trace gases, this approach will be appropriate for measurements of aerosol extinction in ambient air, and this spectral region is important for characterizing the strong ultraviolet absorption by brown carbon aerosol.

  18. Net analyte signal standard addition method (NASSAM) as a novel spectrofluorimetric and spectrophotometric technique for simultaneous determination, application to assay of melatonin and pyridoxine

    NASA Astrophysics Data System (ADS)

    Asadpour-Zeynali, Karim; Bastami, Mohammad

    2010-02-01

    In this work a new modification of the standard addition method called "net analyte signal standard addition method (NASSAM)" is presented for the simultaneous spectrofluorimetric and spectrophotometric analysis. The proposed method combines the advantages of standard addition method with those of net analyte signal concept. The method can be applied for the determination of analyte in the presence of known interferents. The accuracy of the predictions against H-point standard addition method is not dependent on the shape of the analyte and interferent spectra. The method was successfully applied to simultaneous spectrofluorimetric and spectrophotometric determination of pyridoxine (PY) and melatonin (MT) in synthetic mixtures and in a pharmaceutical formulation.

  19. Using FTIR-ATR Spectroscopy to Teach the Internal Standard Method

    ERIC Educational Resources Information Center

    Bellamy, Michael K.

    2010-01-01

    The internal standard method is widely applied in quantitative analyses. However, most analytical chemistry textbooks either omit this topic or only provide examples of a single-point internal standardization. An experiment designed to teach students how to prepare an internal standard calibration curve is described. The experiment is a modified…

  20. Full Simulation for the Qweak Experiment at 1.16 and 0.877 GeV and their Impact on Extracting the PV Asymmetry in the N → Δ Transition.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuhait, Hend

    The Qweak project is seeking to find new physics beyond the Standard Model. It is aimed to measure the weak charge of the proton, which has never been measured, at 4% precision at low momentum transfer. The experiment is performed by scattering electrons from protons and exploiting parity violation in the weak interaction at low four-momentum transfer. In this experiment, two measurements were considered: which are elastic and inelastic. The elastic is to measure the proton's weak charge. In addition, the inelastic asymmetry measurement, which will extract the low energy constant d. That measurement works in the neutral current sectormore » of the weak interaction. Qweak measures the asymmetry in the N → Δ; transition. Because the elastic radiative tail gives a dominant contribution to the uncertainty to the N → Δ; asymmetries, this thesis will discuss the radiative correction. In addition, this thesis will describe in details the extensive simulations preformed to determine the impact of all simulated background processes on extracting the PV N → Δ; asymmetries. In the process of verifying the validity of these background fractions, we determined the best value of a quantity measured during the Qweak experiment: the beam normal single spin asymmetry, Bn, in the N → Δ; transition.« less

  1. Rapid culture-independent microbial analysis aboard the international space station (ISS) stage two: quantifying three microbial biomarkers.

    PubMed

    Morris, Heather C; Damon, Michael; Maule, Jake; Monaco, Lisa A; Wainwright, Norm

    2012-09-01

    Abstract A portable, rapid, microbial detection unit, the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was launched to the International Space Station (ISS) as a technology demonstration unit in December 2006. Results from the first series of experiments designed to detect Gram-negative bacteria on ISS surfaces by quantifying a single microbial biomarker lipopolysaccharide (LPS) were reported in a previous article. Herein, we report additional technology demonstration experiments expanding the on-orbit capabilities of the LOCAD-PTS to detecting three different microbial biomarkers on ISS surfaces. Six different astronauts on more than 20 occasions participated in these experiments, which were designed to test the new beta-glucan (fungal cell wall molecule) and lipoteichoic acid (LTA; Gram-positive bacterial cell wall component) cartridges individually and in tandem with the existing Limulus Amebocyte Lysate (LAL; Gram-negative bacterial LPS detection) cartridges. Additionally, we conducted the sampling side by side with the standard culture-based detection method currently used on the ISS. Therefore, we present data on the distribution of three microbial biomarkers collected from various surfaces in every module present on the ISS at the time of sampling. In accordance with our previous experiments, we determined that spacecraft surfaces known to be frequently in contact with crew members demonstrated higher values of all three microbial molecules. Key Words: Planetary protection-Spaceflight-Microbiology-Biosensor. Astrobiology 12, 830-840.

  2. A comparative study on the effects of barite, ilmenite and bentonite on four suspension feeding bivalves.

    PubMed

    Strachan, Maia F; Kingston, Paul F

    2012-10-01

    The impact of drilling mud components on the filtration activity and survival of bivalve molluscs was investigated by exposing them to suspensions of 'standard' barite, finely milled barite, ilmenite and bentonite in sea water. Introduction of the components stimulated filtration activity in all four bivalves. In addition, the introduction of standard barite and ilmenite both had lethal effects, with none of the bivalves surviving the full duration of the experiments. In-vivo observations of the gill surfaces provided direct evidence of physical damage caused by the administration of barite and ilmenite. A marked difference between filtration activity and survival of animals dosed with 'standard' barite and 'fine' barite suggests that the observed effects were primarily caused by physical interference with gill function. The results also suggest that the use of fine barite in offshore drilling may provide a more favourable environmental impact profile than the use of ilmenite. Copyright © 2012. Published by Elsevier Ltd.

  3. Search for nonstandard neutrino interactions with IceCube DeepCore

    NASA Astrophysics Data System (ADS)

    Aartsen, M. G.; Ackermann, M.; Adams, J.; Aguilar, J. A.; Ahlers, M.; Ahrens, M.; Al Samarai, I.; Altmann, D.; Andeen, K.; Anderson, T.; Ansseau, I.; Anton, G.; Argüelles, C.; Auffenberg, J.; Axani, S.; Bagherpour, H.; Bai, X.; Barron, J. P.; Barwick, S. W.; Baum, V.; Bay, R.; Beatty, J. J.; Becker Tjus, J.; Becker, K.-H.; BenZvi, S.; Berley, D.; Bernardini, E.; Besson, D. Z.; Binder, G.; Bindig, D.; Blaufuss, E.; Blot, S.; Bohm, C.; Börner, M.; Bos, F.; Bose, D.; Böser, S.; Botner, O.; Bourbeau, E.; Bourbeau, J.; Bradascio, F.; Braun, J.; Brayeur, L.; Brenzke, M.; Bretz, H.-P.; Bron, S.; Brostean-Kaiser, J.; Burgman, A.; Carver, T.; Casey, J.; Casier, M.; Cheung, E.; Chirkin, D.; Christov, A.; Clark, K.; Classen, L.; Coenders, S.; Collin, G. H.; Conrad, J. M.; Cowen, D. F.; Cross, R.; Day, M.; de André, J. P. A. M.; De Clercq, C.; DeLaunay, J. J.; Dembinski, H.; De Ridder, S.; Desiati, P.; de Vries, K. D.; de Wasseige, G.; de With, M.; DeYoung, T.; Díaz-Vélez, J. C.; di Lorenzo, V.; Dujmovic, H.; Dumm, J. P.; Dunkman, M.; Dvorak, E.; Eberhardt, B.; Ehrhardt, T.; Eichmann, B.; Eller, P.; Evenson, P. A.; Fahey, S.; Fazely, A. R.; Felde, J.; Filimonov, K.; Finley, C.; Flis, S.; Franckowiak, A.; Friedman, E.; Fuchs, T.; Gaisser, T. K.; Gallagher, J.; Gerhardt, L.; Ghorbani, K.; Giang, W.; Glauch, T.; Glüsenkamp, T.; Goldschmidt, A.; Gonzalez, J. G.; Grant, D.; Griffith, Z.; Haack, C.; Hallgren, A.; Halzen, F.; Hanson, K.; Hebecker, D.; Heereman, D.; Helbing, K.; Hellauer, R.; Hickford, S.; Hignight, J.; Hill, G. C.; Hoffman, K. D.; Hoffmann, R.; Hokanson-Fasig, B.; Hoshina, K.; Huang, F.; Huber, M.; Hultqvist, K.; Hünnefeld, M.; In, S.; Ishihara, A.; Jacobi, E.; Japaridze, G. S.; Jeong, M.; Jero, K.; Jones, B. J. P.; Kalaczynski, P.; Kang, W.; Kappes, A.; Karg, T.; Karle, A.; Katz, U.; Kauer, M.; Keivani, A.; Kelley, J. L.; Kheirandish, A.; Kim, J.; Kim, M.; Kintscher, T.; Kirby, C.; Kiryluk, J.; Kittler, T.; Klein, S. R.; Kohnen, G.; Koirala, R.; Kolanoski, H.; Köpke, L.; Kopper, C.; Kopper, S.; Koschinsky, J. P.; Koskinen, D. J.; Kowalski, M.; Krings, K.; Kroll, M.; Krückl, G.; Kunnen, J.; Kunwar, S.; Kurahashi, N.; Kuwabara, T.; Kyriacou, A.; Labare, M.; Lanfranchi, J. L.; Larson, M. J.; Lauber, F.; Lennarz, D.; Lesiak-Bzdak, M.; Leuermann, M.; Liu, Q. R.; Lu, L.; Lünemann, J.; Luszczak, W.; Madsen, J.; Maggi, G.; Mahn, K. B. M.; Mancina, S.; Maruyama, R.; Mase, K.; Maunu, R.; McNally, F.; Meagher, K.; Medici, M.; Meier, M.; Menne, T.; Merino, G.; Meures, T.; Miarecki, S.; Micallef, J.; Momenté, G.; Montaruli, T.; Moore, R. W.; Moulai, M.; Nahnhauer, R.; Nakarmi, P.; Naumann, U.; Neer, G.; Niederhausen, H.; Nowicki, S. C.; Nygren, D. R.; Obertacke Pollmann, A.; Olivas, A.; O'Murchadha, A.; Palczewski, T.; Pandya, H.; Pankova, D. V.; Peiffer, P.; Pepper, J. A.; Pérez de los Heros, C.; Pieloth, D.; Pinat, E.; Plum, M.; Price, P. B.; Przybylski, G. T.; Raab, C.; Rädel, L.; Rameez, M.; Rawlins, K.; Rea, I. C.; Reimann, R.; Relethford, B.; Relich, M.; Resconi, E.; Rhode, W.; Richman, M.; Robertson, S.; Rongen, M.; Rott, C.; Ruhe, T.; Ryckbosch, D.; Rysewyk, D.; Sälzer, T.; Sanchez Herrera, S. E.; Sandrock, A.; Sandroos, J.; Santander, M.; Sarkar, S.; Sarkar, S.; Satalecka, K.; Schlunder, P.; Schmidt, T.; Schneider, A.; Schoenen, S.; Schöneberg, S.; Schumacher, L.; Seckel, D.; Seunarine, S.; Soedingrekso, J.; Soldin, D.; Song, M.; Spiczak, G. M.; Spiering, C.; Stachurska, J.; Stamatikos, M.; Stanev, T.; Stasik, A.; Stettner, J.; Steuer, A.; Stezelberger, T.; Stokstad, R. G.; Stößl, A.; Strotjohann, N. L.; Stuttard, T.; Sullivan, G. W.; Sutherland, M.; Taboada, I.; Tatar, J.; Tenholt, F.; Ter-Antonyan, S.; Terliuk, A.; Tešić, G.; Tilav, S.; Toale, P. A.; Tobin, M. N.; Toscano, S.; Tosi, D.; Tselengidou, M.; Tung, C. F.; Turcati, A.; Turley, C. F.; Ty, B.; Unger, E.; Usner, M.; Vandenbroucke, J.; Van Driessche, W.; van Eijndhoven, N.; Vanheule, S.; van Santen, J.; Vehring, M.; Vogel, E.; Vraeghe, M.; Walck, C.; Wallace, A.; Wallraff, M.; Wandler, F. D.; Wandkowsky, N.; Waza, A.; Weaver, C.; Weiss, M. J.; Wendt, C.; Werthebach, J.; Westerhoff, S.; Whelan, B. J.; Wiebe, K.; Wiebusch, C. H.; Wille, L.; Williams, D. R.; Wills, L.; Wolf, M.; Wood, J.; Wood, T. R.; Woolsey, E.; Woschnagg, K.; Xu, D. L.; Xu, X. W.; Xu, Y.; Yanez, J. P.; Yodh, G.; Yoshida, S.; Yuan, T.; Zoll, M.; IceCube Collaboration

    2018-04-01

    As atmospheric neutrinos propagate through the Earth, vacuumlike oscillations are modified by Standard Model neutral- and charged-current interactions with electrons. Theories beyond the Standard Model introduce heavy, TeV-scale bosons that can produce nonstandard neutrino interactions. These additional interactions may modify the Standard Model matter effect producing a measurable deviation from the prediction for atmospheric neutrino oscillations. The result described in this paper constrains nonstandard interaction parameters, building upon a previous analysis of atmospheric muon-neutrino disappearance with three years of IceCube DeepCore data. The best fit for the muon to tau flavor changing term is ɛμ τ=-0.0005 , with a 90% C.L. allowed range of -0.0067 <ɛμ τ<0.0081 . This result is more restrictive than recent limits from other experiments for ɛμ τ. Furthermore, our result is complementary to a recent constraint on ɛμ τ using another publicly available IceCube high-energy event selection. Together, they constitute the world's best limits on nonstandard interactions in the μ -τ sector.

  4. Difference in compliance with Standard Precautions by nursing staff in Brazil versus Hong Kong.

    PubMed

    Pereira, Fernanda Maria Vieira; Lam, Simon Ching; Chan, Jackie Hoi Man; Malaguti-Toffano, Silmara Elaine; Gir, Elucir

    2015-07-01

    The Standard Precautions (SP) are measures to reduce the risk of transmission of bloodborne and other pathogens, and should be used by health professionals in the care of all patients regardless of their condition of infection. However, suboptimal compliance with SP has been consistently reported in the nursing literature. This study evaluated the differences of compliance with SP among nurses from Brazil and Hong Kong. This cross-sectional study was conducted in 2 countries-Hong Kong and Brazil-with nurses working in hospitals who responded to a self-administered questionnaire with demographic data and responses to a 20-item Compliance with Standard Precautions Scale. The compliance rate of 560 nurses was 69.4% for the Brazilian sample and 57.4% for the Hong Kong sample. The additional clinical experience of the Brazilian nurses versus those in Hong Kong may be related to differences in compliance with SP between nurses. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. The social effects of poor classroom acoustics on students and The District of Columbia Public Schools demonstration of support through mandating the ANSI Classroom Acoustics standard

    NASA Astrophysics Data System (ADS)

    Ellis, Donna

    2002-11-01

    The effects that poor acoustics have on students extend beyond the classroom. This paper is to discuss the immediate and long-term results that inadequate acoustical design in the educational setting has on academic and social development and how the District of Columbia Public Schools (DCPS) are contributing to the classroom acoustic movement. DCPS is taking a pro-active stance in educational acoustics by mandating the ANSI Draft S12.60-200X classroom acoustic standard in the transformation of ten schools a year for the next ten to fifteen years. Synthesizing the ANSI S12 standard with the DCPS Design Guidelines describes explanation of how to design for appropriate acoustics in all core-learning spaces. Examples of the existing conditions of the facilities and acoustical remediation for new and historical preservation projects will be demonstrated. In addition, experience will be shared on the International Building Code Council hearings for classroom acoustics.

  6. Measuring Generalized Trust: An Examination of Question Wording and the Number of Scale Points.

    PubMed

    Lundmark, Sebastian; Gilljam, Mikael; Dahlberg, Stefan

    2016-01-01

    Survey institutes recently have changed their measurement of generalized trust from the standard dichotomous scale to an 11-point scale. Additionally, numerous survey institutes use different question wordings: where most rely on the standard, fully balanced question (asking if "most people can be trusted or that you need to be very careful in dealing with people"), some use minimally balanced questions, asking only if it is "possible to trust people." By using two survey-embedded experiments, one with 12,009 self-selected respondents and the other with a probability sample of 2,947 respondents, this study evaluates the generalized trust question in terms of question wording and number of scale points used. Results show that, contrary to the more commonly used standard question format (used, for example, by the American National Election Studies and the General Social Survey), generalized trust is best measured with a minimally balanced question wording accompanied with either a seven- or an 11-point scale.

  7. Research and Development of Natural Draft Ultra-Low Emissions Burners for Gas Appliances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Therkelsen, Peter; Cheng, Robert; Sholes, Darren

    Combustion systems used in residential and commercial cooking appliances must be robust and easy to use while meeting air quality standards. Current air quality standards for cooking appliances are far greater than other stationary combustion equipment. By developing an advanced low emission combustion system for cooking appliances, the air quality impacts from these devices can be reduced. This project adapted the Lawrence Berkeley National Laboratory (LBNL) Ring-Stabilizer Burner combustion technology for residential and commercial natural gas fired cooking appliances (such as ovens, ranges, and cooktops). LBNL originally developed the Ring-Stabilizer Burner for a NASA funded microgravity experiment. This natural draftmore » combustion technology reduces NOx emissions significantly below current SCAQMD emissions standards without post combustion treatment. Additionally, the Ring-Stabilizer Burner technology does not require the assistance of a blower to achieve an ultra-low emission lean premix flame. The research team evaluated the Ring-Stabilizer Burner and fabricated the most promising designs based on their emissions and turndown.« less

  8. Advancing nursing leadership: a model for program implementation and measurement.

    PubMed

    Omoike, Osei; Stratton, Karen M; Brooks, Beth A; Ohlson, Susan; Storfjell, Judy Lloyd

    2011-01-01

    Despite the abundant literature documenting the need for nurse management education and career development, only recently have professional standards been targeted for this group. Competency standards for nurse leaders repeatedly identify systems-level concepts including finance and budget, communication skills, strategic management, human resources management, change management, and computer technology skills. However, educational initiatives to meet these standards are still at the early stages and most nurse leaders continue to acquire knowledge and experience through "on-the-job" training. This article will illustrate the need for partnerships and collaboration between academia and hospitals to advance nursing leadership to the next century. In addition, a tool to measure the impact of a graduate certificate program in nursing administration on nurse leader competencies is presented. Overall, the certificate program has been successful in multiple ways; it has "graduated" almost 80 nurse leaders, improved participant competence in their role at the systems level, as well as providing an impetus for completion of a graduate degree post program.

  9. 75 FR 68608 - Information Collection; Request for Authorization of Additional Classification and Rate, Standard...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-08

    ... Authorization of Additional Classification and Rate, Standard Form 1444 AGENCY: Department of Defense (DOD... of Additional Classification and Rate, Standard Form 1444. DATES: Comments may be submitted on or.../or business confidential information provided. FOR FURTHER INFORMATION CONTACT: Mr. Ernest Woodson...

  10. Search for new phenomena in a lepton plus high jet multiplicity final state with the ATLAS experiment using √{s}=13 TeV proton-proton collision data

    NASA Astrophysics Data System (ADS)

    Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; AbouZeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abreu, R.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Agatonovic-Jovin, T.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Akerstedt, H.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Verzini, M. J. Alconada; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M.; Gonzalez, B. Alvarez; Piqueras, D. Álvarez; Alviggi, M. G.; Amadio, B. T.; Coutinho, Y. Amaral; Amelung, C.; Amidei, D.; Santos, S. P. Amor Dos; Amorim, A.; Amoroso, S.; Amundsen, G.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Anjos, N.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Bella, L. Aperio; Arabidze, G.; Arai, Y.; Araque, J. P.; Ferraz, V. Araujo; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Arik, M.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Backhaus, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barklow, T.; Barlow, N.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Navarro, L. Barranco; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Beckingham, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Beltramello, O.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Bendtz, K.; Benekos, N.; Benhammou, Y.; Noccioli, E. Benhar; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Kuutmann, E. Bergeaas; Berger, N.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertolucci, F.; Bertram, I. A.; Bertsche, C.; Bertsche, D.; Besjes, G. J.; Bylund, O. Bessidskaia; Bessner, M.; Besson, N.; Betancourt, C.; Bethani, A.; Bethke, S.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bilokon, H.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, C. W.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blum, W.; Blumenschein, U.; Blunier, S.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boehler, M.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Sola, J. D. Bossio; Boudreau, J.; Bouffard, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Bratzler, U.; Brau, B.; Brau, J. E.; Madden, W. D. Breaden; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brochu, F. M.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brosamer, J.; Brost, E.; Broughton, J. H.; de Renstrom, P. A. Bruckman; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Brunt, BH; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Busato, E.; Büscher, D.; Büscher, V.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Urbán, S. Cabrera; Caforio, D.; Cairo, V. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Lopez, S. Calvente; Calvet, D.; Calvet, S.; Calvet, T. P.; Toro, R. Camacho; Camarda, S.; Camarri, P.; Cameron, D.; Armadans, R. Caminal; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Bret, M. Cano; Cantero, J.; Cao, T.; Garrido, M. D. M. Capeans; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Carvalho, J.; Casadei, D.; Casado, M. P.; Casolino, M.; Casper, D. W.; Castelijn, R.; Gimenez, V. Castillo; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Alberich, L. Cerda; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Barajas, C. A. Chavez; Che, S.; Cheatham, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, H.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; El Moursli, R. Cherkaoui; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Christodoulou, V.; Chromek-Burckhart, D.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Ciftci, A. K.; Cinca, D.; Cindro, V.; Cioara, I. A.; Ciocca, C.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Ciubancan, M.; Clark, A.; Clark, B. L.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Colombo, T.; Muiño, P. Conde; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooke, M.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corriveau, F.; Cortes-Gonzalez, A.; Cortiana, G.; Costa, G.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cribbs, W. A.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Donszelmann, T. Cuhadar; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czodrowski, P.; D'amen, G.; D'Auria, S.; D'eramo, L.; D'Onofrio, M.; Da Cunha Sargedas De Sousa, M. J.; Da Via, C.; Dabrowski, W.; Dado, T.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Daniells, A. C.; Dann, N. S.; Danninger, M.; Hoffmann, M. Dano; Dao, V.; Darbo, G.; Darmora, S.; Dassoulas, J.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; De, K.; de Asmundis, R.; De Benedetti, A.; De Castro, S.; De Cecco, S.; De Groot, N.; de Jong, P.; De la Torre, H.; De Lorenzi, F.; De Maria, A.; De Pedis, D.; De Salvo, A.; De Sanctis, U.; De Santo, A.; De Vasconcelos Corga, K.; De Vivie De Regie, J. B.; Dearnaley, W. J.; Debbe, R.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Dell'Orso, M.; Pietra, M. Della; della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; DeMarco, D. A.; Demers, S.; Demichev, M.; Demilly, A.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; Di Bello, F. A.; Di Ciaccio, A.; Di Ciaccio, L.; Di Clemente, W. K.; Di Donato, C.; Di Girolamo, A.; Di Girolamo, B.; Di Micco, B.; Di Nardo, R.; Di Petrillo, K. F.; Di Simone, A.; Di Sipio, R.; Di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Diehl, E. B.; Dietrich, J.; Cornell, S. Díez; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; do Vale, M. A. B.; Dobos, D.; Dobre, M.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Dondero, P.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Yildiz, H. Duran; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Dyndal, M.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Elles, S.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Endner, O. C.; Ennis, J. S.; Erdmann, J.; Ereditato, A.; Ernst, M.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Pastor, O. Estrada; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Falla, R. J.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, C.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Giannelli, M. Faucci; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, H.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Martinez, P. Fernandez; Perez, S. Fernandez; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; de Lima, D. E. Ferreira; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filipuzzi, M.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, A.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Castillo, L. R. Flores; Flowerdew, M. J.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabaldon, C.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Walls, F. M. Garay; García, C.; Navarro, J. E. García; Pascual, J. A. García; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Bravo, A. Gascon; Gasnikova, K.; Gatti, C.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Gershon, A.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giokaris, N.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugni, D.; Giuli, F.; Giuliani, C.; Giulini, M.; Gjelsten, B. K.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Gama, R. Goncalves; Goncalves Pinto Firmino Da Costa, J.; Gonella, G.; Gonella, L.; Gongadze, A.; de la Hoz, S. González; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorelov, I.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Gozani, E.; Graber, L.; Grabowska-Bold, I.; Gradin, P. O. J.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guescini, F.; Guest, D.; Gueta, O.; Gui, B.; Guido, E.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gupta, S.; Gustavino, G.; Gutierrez, P.; Ortiz, N. G. Gutierrez; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Hamnett, P. G.; Han, L.; Han, S.; Hanagaki, K.; Hanawa, K.; Hance, M.; Haney, B.; Hanke, P.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Hariri, F.; Harkusha, S.; Harrington, R. D.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayakawa, D.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Head, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Correia, A. M. Henriques; Henrot-Versille, S.; Herbert, G. H.; Herde, H.; Herget, V.; Jiménez, Y. Hernández; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hodgson, P.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Holmes, T. R.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Hostachy, J.-Y.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Hughes, G.; Huhtinen, M.; Huo, P.; Huseynov, N.; Huston, J.; Huth, J.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Ilchenko, Y.; Iliadis, D.; Ilic, N.; Introzzi, G.; Ioannou, P.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Ponce, J. M. Iturbe; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javůrek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Pena, J. Jimenez; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Rozas, A. Juste; Köhler, M. K.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanaya, N.; Kanjir, L.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Karthik, K.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kiuchi, K.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Komar, A. A.; Komori, Y.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Kopeliansky, R.; Koperny, S.; Kopp, A. K.; Korcyl, K.; Kordas, K.; Korn, A.; Korol, A. A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kucuk, H.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kus, V.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; Kyriazopoulos, D.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lagouri, T.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Manghi, F. Lasagni; Lassnig, M.; Laurelli, P.; Lavrijsen, W.; Law, A. T.; Laycock, P.; Lazovich, T.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; LeBlanc, M.; LeCompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, G.; Lefebvre, M.; Legger, F.; Leggett, C.; Miotto, G. Lehmann; Lei, X.; Leight, W. A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, Changqiao; Li, H.; Li, L.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Liebal, J.; Liebig, W.; Limosani, A.; Lin, S. C.; Lin, T. H.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J.; Liu, J. B.; Liu, K.; Liu, L.; Liu, M.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Merino, J. Llorente; Lloyd, S. L.; Lo, C. Y.; Sterzo, F. Lo; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Loginov, A.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Mateos, D. Lopez; Paz, I. Lopez; Solis, A. Lopez; Lorenz, J.; Martinez, N. Lorenzo; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lundberg, O.; Lund-Jensen, B.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; Macdonald, C. M.; Maček, B.; Miguens, J. Machado; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Mahlstedt, J.; Maiani, C.; Maidantchik, C.; Maier, A. A.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Ramos, J. Manjarres; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Mapelli, L.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marsden, S. P.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; dit Latour, B. Martin; Martinez, M.; Outschoorn, V. I. Martinez; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Fadden, N. C. Mc; Goldrick, G. Mc; Kee, S. P. Mc; McCarn, A.; McCarthy, R. L.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; Mcfayden, J. A.; Mchedlidze, G.; McMahon, S. J.; McNamara, P. C.; McPherson, R. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Garcia, B. R. Mellado; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Theenhausen, H. Meyer Zu; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Miller, D. W.; Mills, C.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minami, Y.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Monden, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Berlingen, J. Montejo; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Llácer, M. Moreno; Morettini, P.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Sanchez, F. J. Munoz; Murray, W. J.; Musheghyan, H.; Muškinja, M.; Myagkov, A. G.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Garcia, R. F. Naranjo; Narayan, R.; Villar, D. I. Narrias; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, A.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Manh, T. Nguyen; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsen, J. K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Nowak, S.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Seabra, L. F. Oleiro; Pino, S. A. Olivares; Damazio, D. Oliveira; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pages, A. Pacheco; Rodriguez, L. Pacheco; Aranda, C. Padilla; Griso, S. Pagan; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Vazquez, J. G. Panduro; Pani, P.; Panitkin, S.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Hernandez, D. Paredes; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Lopez, S. Pedraza; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Perini, L.; Pernegger, H.; Perrella, S.; Peschke, R.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Piccaro, E.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pin, A. W. J.; Pinamonti, M.; Pinfold, J. L.; Pirumov, H.; Pitt, M.; Plazak, L.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pohl, D.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Pommès, K.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Poppleton, A.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Poulard, G.; Poulsen, T.; Poveda, J.; Astigarraga, M. E. Pozo; Pralavorio, P.; Pranko, A.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, G.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Quilty, D.; Raddum, S.; Radeka, V.; Radescu, V.; Radhakrishnan, S. K.; Radloff, P.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rangel-Smith, C.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Rezvani, R.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rieger, J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Bosca, S. Rodriguez; Perez, A. Rodriguez; Rodriguez, D. Rodriguez; Roe, S.; Rogan, C. S.; Røhne, O.; Roloff, J.; Romaniouk, A.; Romano, M.; Saez, S. M. Romano; Adam, E. Romero; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Tehrani, F. Safai; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Sakurai, Y.; Salamanna, G.; Loyola, J. E. Salazar; Salek, D.; De Bruin, P. H. Sales; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Martinez, V. Sanchez; Pineda, A. Sanchez; Sandaker, H.; Sandbach, R. L.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Castillo, I. Santoyo; Sapronov, A.; Saraiva, J. G.; Sarrazin, B.; Sasaki, O.; Sato, K.; Sauvan, E.; Savage, G.; Savard, P.; Savic, N.; Sawyer, C.; Sawyer, L.; Saxon, J.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Scarcella, M.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaefer, R.; Schaeffer, J.; Schaepe, S.; Schaetzel, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillo, C.; Schioppa, M.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schoenrock, B. D.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultens, M. J.; Schultz-Coulon, H.-C.; Schulz, H.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Seuster, R.; Severini, H.; Sfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Saadi, D. Shoaleh; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Shupe, M. A.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Haddad, E. Sideras; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silverstein, S. B.; Simak, V.; Simic, Lj.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Sanchez, C. A. Solans; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Sopczak, A.; Sosa, D.; Sotiropoulou, C. L.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; Denis, R. D. St.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stewart, G. A.; Stockton, M. C.; Stoebe, M.; Stoicea, G.; Stolte, P.; Stonjek, S.; Stradling, A. R.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, DMS; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanaka, S.; Tanioka, R.; Tannenwald, B. B.; Araya, S. Tapia; Tapprogge, S.; Tarem, S.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Delgado, A. Tavares; Tayalati, Y.; Taylor, A. C.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Theveneaux-Pelzer, T.; Thomas, J. P.; Thomas-Wilsker, J.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tibbetts, M. J.; Torres, R. E. Ticse; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomlinson, L.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Pastor, E. Torró; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trottier-McDonald, M.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsipolitis, G.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsui, K. M.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Tupputi, S. A.; Turchikhin, S.; Turgeman, D.; Cakir, I. Turk; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Unverdorben, C.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vaidya, A.; Valderanis, C.; Santurio, E. Valdes; Valentinetti, S.; Valero, A.; Valéry, L.; Valkar, S.; Vallier, A.; Ferrer, J. A. Valls; Van Den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; Van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vardanyan, G.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Schroeder, T. Vazquez; Veatch, J.; Veeraraghavan, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Venturini, A.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Maira, N. Viaux; Viazlo, O.; Vichou, I.; Vickey, T.; Boeriu, O. E. Vickey; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Perez, M. Villaplana; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von der Schmitt, H.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Voss, R.; Vossebeld, J. H.; Vranjes, N.; Milosavljevic, M. Vranjes; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakabayashi, J.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, C.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. W.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Weits, H.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Worm, S. D.; Wosiek, B. K.; Wotschack, J.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Yabsley, B.; Yacoob, S.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamamoto, S.; Yamanaka, T.; Yamatani, M.; Yamauchi, K.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Wong, K. H. Yau; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zaman, A.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zemla, A.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, C.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; zur Nedden, M.; Zwalinski, L.

    2017-09-01

    A search for new phenomena in final states characterized by high jet multiplicity, an isolated lepton (electron or muon) and either zero or at least three b-tagged jets is presented. The search uses 36.1 fb-1 of √{s}=13 TeV proton-proton collision data collected by the ATLAS experiment at the Large Hadron Collider in 2015 and 2016. The dominant sources of background are estimated using parameterized extrapolations, based on observables at medium jet multiplicity, to predict the b-tagged jet multiplicity distribution at the higher jet multiplicities used in the search. No significant excess over the Standard Model expectation is observed and 95% confidence-level limits are extracted constraining four simplified models of R-parity-violating supersymmetry that feature either gluino or top-squark pair production. The exclusion limits reach as high as 2.1 TeV in gluino mass and 1.2 TeV in top-squark mass in the models considered. In addition, an upper limit is set on the cross-section for Standard Model t\\overline{t}t\\overline{t} production of 60 fb (6.5 × the Standard Model prediction) at 95% confidence level. Finally, model-independent limits are set on the contribution from new phenomena to the signal-region yields. [Figure not available: see fulltext.

  11. What do I do? Developing a taxonomy of chaplaincy activities and interventions for spiritual care in intensive care unit palliative care.

    PubMed

    Massey, Kevin; Barnes, Marilyn J D; Villines, Dana; Goldstein, Julie D; Pierson, Anna Lee Hisey; Scherer, Cheryl; Vander Laan, Betty; Summerfelt, Wm Thomas

    2015-01-01

    Chaplains are increasingly seen as key members of interdisciplinary palliative care teams, yet the specific interventions and hoped for outcomes of their work are poorly understood. This project served to develop a standard terminology inventory for the chaplaincy field, to be called the chaplaincy taxonomy. The research team used a mixed methods approach to generate, evaluate and validate items for the taxonomy. We conducted a literature review, retrospective chart review, focus groups, self-observation, experience sampling, concept mapping, and reliability testing. Chaplaincy activities focused primarily on palliative care in an intensive care unit setting in order to capture a broad cross section of chaplaincy activities. Literature and chart review resulted in 438 taxonomy items for testing. Chaplain focus groups generated an additional 100 items and removed 421 items as duplications. Self-Observation, Experience Sampling and Concept Mapping provided validity that the taxonomy items were actual activities that chaplains perform in their spiritual care. Inter-rater reliability for chaplains to identify taxonomy items from vignettes was 0.903. The 100 item chaplaincy taxonomy provides a strong foundation for a normative inventory of chaplaincy activities and outcomes. A deliberative process is proposed to further expand and refine the taxonomy to create a standard terminological inventory for the field of chaplaincy. A standard terminology could improve the ways inter-disciplinary palliative care teams communicate about chaplaincy activities and outcomes.

  12. Bioinformatics in the secondary science classroom: A study of state content standards and students' perceptions of, and performance in, bioinformatics lessons

    NASA Astrophysics Data System (ADS)

    Wefer, Stephen H.

    The proliferation of bioinformatics in modern Biology marks a new revolution in science, which promises to influence science education at all levels. This thesis examined state standards for content that articulated bioinformatics, and explored secondary students' affective and cognitive perceptions of, and performance in, a bioinformatics mini-unit. The results are presented as three studies. The first study analyzed secondary science standards of 49 U.S States (Iowa has no science framework) and the District of Columbia for content related to bioinformatics at the introductory high school biology level. The bionformatics content of each state's Biology standards were categorized into nine areas and the prevalence of each area documented. The nine areas were: The Human Genome Project, Forensics, Evolution, Classification, Nucleotide Variations, Medicine, Computer Use, Agriculture/Food Technology, and Science Technology and Society/Socioscientific Issues (STS/SSI). Findings indicated a generally low representation of bioinformatics related content, which varied substantially across the different areas. Recommendations are made for reworking existing standards to incorporate bioinformatics and to facilitate the goal of promoting science literacy in this emerging new field among secondary school students. The second study examined thirty-two students' affective responses to, and content mastery of, a two-week bioinformatics mini-unit. The findings indicate that the students generally were positive relative to their interest level, the usefulness of the lessons, the difficulty level of the lessons, likeliness to engage in additional bioinformatics, and were overall successful on the assessments. A discussion of the results and significance is followed by suggestions for future research and implementation for transferability. The third study presents a case study of individual differences among ten secondary school students, whose cognitive and affective percepts were analyzed in relation to their experience in learning a bioinformatics mini-unit. There were distinct individual differences among the participants, especially in the way they processed information and integrated procedural and analytical thought during bioinformatics learning. These differences may provide insights into some of the specific needs of students that educators and curriculum designers should consider when designing bioinformatics learning experiences. Implications for teacher education and curriculum design are presented in addition to some suggestions for further research.

  13. Analysis of redox additive-based overcharge protection for rechargeable lithium batteries

    NASA Technical Reports Server (NTRS)

    Narayanan, S. R.; Surampudi, S.; Attia, A. I.; Bankston, C. P.

    1991-01-01

    The overcharge condition in secondary lithium batteries employing redox additives for overcharge protection, has been theoretically analyzed in terms of a finite linear diffusion model. The analysis leads to expressions relating the steady-state overcharge current density and cell voltage to the concentration, diffusion coefficient, standard reduction potential of the redox couple, and interelectrode distance. The model permits the estimation of the maximum permissible overcharge rate for any chosen set of system conditions. Digital simulation of the overcharge experiment leads to numerical representation of the potential transients, and estimate of the influence of diffusion coefficient and interelectrode distance on the transient attainment of the steady state during overcharge. The model has been experimentally verified using 1,1-prime-dimethyl ferrocene as a redox additive. The analysis of the experimental results in terms of the theory allows the calculation of the diffusion coefficient and the formal potential of the redox couple. The model and the theoretical results may be exploited in the design and optimization of overcharge protection by the redox additive approach.

  14. Assessment of statistic analysis in non-radioisotopic local lymph node assay (non-RI-LLNA) with alpha-hexylcinnamic aldehyde as an example.

    PubMed

    Takeyoshi, Masahiro; Sawaki, Masakuni; Yamasaki, Kanji; Kimber, Ian

    2003-09-30

    The murine local lymph node assay (LLNA) is used for the identification of chemicals that have the potential to cause skin sensitization. However, it requires specific facility and handling procedures to accommodate a radioisotopic (RI) endpoint. We have developed non-radioisotopic (non-RI) endpoint of LLNA based on BrdU incorporation to avoid a use of RI. Although this alternative method appears viable in principle, it is somewhat less sensitive than the standard assay. In this study, we report investigations to determine the use of statistical analysis to improve the sensitivity of a non-RI LLNA procedure with alpha-hexylcinnamic aldehyde (HCA) in two separate experiments. Consequently, the alternative non-RI method required HCA concentrations of greater than 25% to elicit a positive response based on the criterion for classification as a skin sensitizer in the standard LLNA. Nevertheless, dose responses to HCA in the alternative method were consistent in both experiments and we examined whether the use of an endpoint based upon the statistical significance of induced changes in LNC turnover, rather than an SI of 3 or greater, might provide for additional sensitivity. The results reported here demonstrate that with HCA at least significant responses were, in each of two experiments, recorded following exposure of mice to 25% of HCA. These data suggest that this approach may be more satisfactory-at least when BrdU incorporation is measured. However, this modification of the LLNA is rather less sensitive than the standard method if employing statistical endpoint. Taken together the data reported here suggest that a modified LLNA in which BrdU is used in place of radioisotope incorporation shows some promise, but that in its present form, even with the use of a statistical endpoint, lacks some of the sensitivity of the standard method. The challenge is to develop strategies for further refinement of this approach.

  15. Improving Groundwater Data Interoperability: Results of the Second OGC Groundwater Interoperability Experiment

    NASA Astrophysics Data System (ADS)

    Lucido, J. M.; Booth, N.

    2014-12-01

    Interoperable sharing of groundwater data across international boarders is essential for the proper management of global water resources. However storage and management of groundwater data is often times distributed across many agencies or organizations. Furthermore these data may be represented in disparate proprietary formats, posing a significant challenge for integration. For this reason standard data models are required to achieve interoperability across geographical and political boundaries. The GroundWater Markup Language 1.0 (GWML1) was developed in 2010 as an extension of the Geography Markup Language (GML) in order to support groundwater data exchange within Spatial Data Infrastructures (SDI). In 2013, development of GWML2 was initiated under the sponsorship of the Open Geospatial Consortium (OGC) for intended adoption by the international community as the authoritative standard for the transfer of groundwater feature data, including data about water wells, aquifers, and related entities. GWML2 harmonizes GWML1 and the EU's INSPIRE models related to geology and hydrogeology. Additionally, an interoperability experiment was initiated to test the model for commercial, technical, scientific, and policy use cases. The scientific use case focuses on the delivery of data required for input into computational flow modeling software used to determine the flow of groundwater within a particular aquifer system. It involves the delivery of properties associated with hydrogeologic units, observations related to those units, and information about the related aquifers. To test this use case web services are being implemented using GWML2 and WaterML2, which is the authoritative standard for water time series observations, in order to serve USGS water well and hydrogeologic data via standard OGC protocols. Furthermore, integration of these data into a computational groundwater flow model will be tested. This submission will present the GWML2 information model and results of an interoperability experiment with a particular emphasis on the scientific use case.

  16. Application of standard addition for the determination of carboxypeptidase activity in Actinomucor elegans bran koji.

    PubMed

    Fu, J; Li, L; Yang, X Q; Zhu, M J

    2011-01-01

    Leucine carboxypeptidase (EC 3.4.16) activity in Actinomucor elegans bran koji was investigated via absorbance at 507 nm after stained by Cd-nihydrin solution, with calibration curve A, which was made by a set of known concentration standard leucine, calibration B, which was made by three sets of known concentration standard leucine solutions with the addition of three concentrations inactive crude enzyme extract, and calibration C, which was made by three sets of known concentration standard leucine solutions with the addition of three concentrations crude enzyme extract. The results indicated that application of pure amino acid standard curve was not a suitable way to determine carboxypeptidase in complicate mixture, and it probably led to overestimated carboxypeptidase activity. It was found that addition of crude exact into pure amino acid standard curve had a significant difference from pure amino acid standard curve method (p < 0.05). There was no significant enzyme activity difference (p > 0.05) between addition of active crude exact and addition of inactive crude kind, when the proper dilute multiple was used. It was concluded that the addition of crude enzyme extract to the calibration was needed to eliminate the interference of free amino acids and related compounds presented in crude enzyme extract.

  17. Basic Wind Tech Course - Lesson Plans and Activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swapp, Andy

    2011-07-01

    The funds from this project were used to purchase tools and instrumentation to help replicate actual on-the-job wind energy scenarios which provided the students with the practical or applied components of wind energy jobs. This project enhanced the educational experiences provided for the students in terms of engineering and science components of wind energy by using electronics, control systems, and electro-mechanical instrumentation to help students learn standardized wind-specific craftsman skills. In addition the tools and instrumentation helped the students learn the safety necessary to work in the wind industry.

  18. Model-Independent Bounds on Kinetic Mixing

    DOE PAGES

    Hook, Anson; Izaguirre, Eder; Wacker, Jay G.

    2011-01-01

    New Abelimore » an vector bosons can kinetically mix with the hypercharge gauge boson of the Standard Model. This letter computes the model-independent limits on vector bosons with masses from 1 GeV to 1 TeV. The limits arise from the numerous e + e − experiments that have been performed in this energy range and bound the kinetic mixing by ϵ ≲ 0.03 for most of the mass range studied, regardless of any additional interactions that the new vector boson may have.« less

  19. A combined toxicity study of zinc oxide nanoparticles and vitamin C in food additives

    NASA Astrophysics Data System (ADS)

    Wang, Yanli; Yuan, Lulu; Yao, Chenjie; Ding, Lin; Li, Chenchen; Fang, Jie; Sui, Keke; Liu, Yuanfang; Wu, Minghong

    2014-11-01

    At present, safety evaluation standards for nanofood additives are made based on the toxic effects of a single additive. Since the size, surface properties and chemical nature influence the toxicity of nanomaterials, the toxicity may have dramatically changed when nanomaterials are used as food additives in a complex system. Herein, we investigated the combined toxicity of zinc oxide nanoparticles (ZnO NPs) and vitamin C (Vc, ascorbic acid). The results showed that Vc increased the cytotoxicity significantly compared with that of the ZnO only NPs. When the cells were exposed to ZnO NPs at a concentration less than 15 mg L-1, or to Vc at a concentration less than 300 mg L-1, there was no significant cytotoxicity, both in the case of gastric epithelial cell line (GES-1) and neural stem cells (NSCs). However, when 15 mg L-1 of ZnO NPs and 300 mg L-1 of Vc were introduced to cells together, the cell viability decreased sharply indicating significant cytotoxicity. Moreover, the significant increase in toxicity was also shown in the in vivo experiments. The dose of the ZnO NPs and Vc used in the in vivo study was calculated according to the state of food and nutrition enhancer standard. After repeated oral exposure to ZnO NPs plus Vc, the injury of the liver and kidneys in mice has been indicated by the change of these indices. These findings demonstrate that the synergistic toxicity presented in a complex system is essential for the toxicological evaluation and safety assessment of nanofood.At present, safety evaluation standards for nanofood additives are made based on the toxic effects of a single additive. Since the size, surface properties and chemical nature influence the toxicity of nanomaterials, the toxicity may have dramatically changed when nanomaterials are used as food additives in a complex system. Herein, we investigated the combined toxicity of zinc oxide nanoparticles (ZnO NPs) and vitamin C (Vc, ascorbic acid). The results showed that Vc increased the cytotoxicity significantly compared with that of the ZnO only NPs. When the cells were exposed to ZnO NPs at a concentration less than 15 mg L-1, or to Vc at a concentration less than 300 mg L-1, there was no significant cytotoxicity, both in the case of gastric epithelial cell line (GES-1) and neural stem cells (NSCs). However, when 15 mg L-1 of ZnO NPs and 300 mg L-1 of Vc were introduced to cells together, the cell viability decreased sharply indicating significant cytotoxicity. Moreover, the significant increase in toxicity was also shown in the in vivo experiments. The dose of the ZnO NPs and Vc used in the in vivo study was calculated according to the state of food and nutrition enhancer standard. After repeated oral exposure to ZnO NPs plus Vc, the injury of the liver and kidneys in mice has been indicated by the change of these indices. These findings demonstrate that the synergistic toxicity presented in a complex system is essential for the toxicological evaluation and safety assessment of nanofood. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05480f

  20. Workflow standardization of a novel team care model to improve chronic care: a quasi-experimental study.

    PubMed

    Panattoni, Laura; Hurlimann, Lily; Wilson, Caroline; Durbin, Meg; Tai-Seale, Ming

    2017-04-19

    Team-based chronic care models have not been widely adopted in community settings, partly due to their varying effectiveness in randomized control trials, implementation challenges, and concerns about physician acceptance. The Palo Alto Medical Foundation designed and implemented "Champion," a novel team-based model that includes new standard work (e.g. proactive patient outreach, pre-visit schedule grooming, depression screening, care planning, health coaching) to support patients' self-management of hypertension and diabetes. We investigated whether Champion improved clinical outcomes. We conducted a quasi-experimental study comparing the Champion clinic-level intervention (n = 38 physicians) with a usual care clinic (n = 37 physicians) in Northern California. The primary outcomes, blood pressure and glycohemoglobin (A1c), were analyzed using a piecewise linear growth curve model for patients exposed to a Champion physician visit (n = 3156) or usual care visit (n = 8034) in the two years prior and one year post implementation. Secondary outcomes were provider experience, compared at baseline and 12 months in both the intervention and usual care clinics using multi-level ordered logistic modeling, and electronic health record based fidelity measures. Compared to usual care, in the first 6 months after a Champion physician visit, diabetes patients aged 18-75 experienced an additional -1.13 mm Hg (95% CI: -2.23 to -0.04) decline in diastolic blood pressure and -0.47 (95% CI: -0.61 to -0.33) decline in A1c. There were no additional improvements in blood pressure or A1c 6 to 12 months post physician visit. At 12 months, Champion physicians reported improved experience with managing chronic care patients in 6 of 7 survey items (p < 0.05), but compared to usual, this difference was only statistically significant for one item (p < 0.05). Fidelity to standard work was uneven; depression screening was the most commonly documented element (85% of patients), while care plans were the least (30.8% of patients). Champion standard work improved glycemic control over the first 6 months and physicians' experience with managing chronic care; changes in blood pressure were not clinically meaningful. Our results suggest the need to understand the relationship between the intervention, the contextual features of implementation, and fidelity to further improve chronic disease outcomes. This study was retrospectively registered with the ISRCTN Registry on March 15, 2017 (ISRCTN11341906).

  1. Teachers' Experiences with Integrating Play-Based Learning into Standards-Driven Curriculum: A Phenomenological Study

    ERIC Educational Resources Information Center

    Nugent, Mary Beth Anderson

    2017-01-01

    The purpose of this phenomenological study was to describe kindergarten teachers' experiences with integrating play-based learning into standards-based academic curriculum in a school district in South Carolina. Play-based learning experiences were defined as instances which allow children to engage in active, social learning experiences in…

  2. Does attainment of Piaget's formal operational level of cognitive development predict student understanding of scientific models?

    NASA Astrophysics Data System (ADS)

    Lahti, Richard Dennis, II

    Knowledge of scientific models and their uses is a concept that has become a key benchmark in many of the science standards of the past 30 years, including the proposed Next Generation Science Standards. Knowledge of models is linked to other important nature of science concepts such as theory change which are also rising in prominence in newer standards. Effective methods of instruction will need to be developed to enable students to achieve these standards. The literature reveals an inconsistent history of success with modeling education. These same studies point to a possible cognitive development component which might explain why some students succeeded and others failed. An environmental science course, rich in modeling experiences, was used to test both the extent to which knowledge of models and modeling could be improved over the course of one semester, and more importantly, to identify if cognitive ability was related to this improvement. In addition, nature of science knowledge, particularly related to theories and theory change, was also examined. Pretest and posttest results on modeling (SUMS) and nature of science (SUSSI), as well as data from the modeling activities themselves, was collected. Cognitive ability was measured (CTSR) as a covariate. Students' gain in six of seven categories of modeling knowledge was at least medium (Cohen's d >.5) and moderately correlated to CTSR for two of seven categories. Nature of science gains were smaller, although more strongly correlated with CTSR. Student success at creating a model was related to CTSR, significantly in three of five sub-categories. These results suggest that explicit, reflective experience with models can increase student knowledge of models and modeling (although higher cognitive ability students may have more success), but successfully creating models may depend more heavily on cognitive ability. This finding in particular has implications in the grade placement of modeling standards and curriculum chosen to help these students, particularly those with low cognitive ability, to meet the standards.

  3. Comparison of short-term chronic and chronic silver toxicity to fathead minnows in unamended and sodium chloride-amended waters.

    PubMed

    Naddy, Rami B; Rehner, Anita B; McNerney, Gina R; Gorsuch, Joseph W; Kramer, James R; Wood, Chris M; Paquin, Paul R; Stubblefield, William A

    2007-09-01

    The chronic (early life stage [ELS]) and short-term chronic (STC) toxicity of silver (as silver nitrate) to fathead minnows (FHM) was determined concurrently in flow-through exposures (33 volume additions/d). Paired ELS (approximately 30 d) and STC (7 d) studies were conducted with and without the addition of 60 mg/L Cl (as NaCl). The paired studies in unamended water were later repeated using standard flow conditions (9 volume additions/d). The purpose of the paired studies was to determine if short-term chronic endpoints can be used to predict effects in ELS studies. For each experiment, a "split-chamber" design (organisms were held in a common exposure chamber) allowed the direct comparison between short-term and chronic exposures. It appeared that the chronic toxicity of silver was mitigated to some extent by NaCl addition. The maximum acceptable toxicant concentration for growth in the ELS study was 0.53 microg dissolved Ag/L under standard flow conditions. Early life stage and STC endpoints in all three studies typically agreed within a factor of two. Whole-body sodium and silver concentrations measured in individual fathead minnows during these studies showed an increase in silver body burdens and a decrease in sodium concentration. These results indicate that the STC study could be used as a surrogate test to estimate chronic toxicity and that the mechanism of chronic silver toxicity may be the same as for acute toxicity.

  4. High levels of anomalous self-experience are associated with longer duration of untreated psychosis.

    PubMed

    Haug, Elisabeth; Øie, Merete; Andreassen, Ole A; Bratlien, Unni; Nelson, Barnaby; Melle, Ingrid; Møller, Paul

    2017-04-01

    To investigate the relationship between anomalous self-experiences and duration of untreated psychosis in a sample of patients with first-episode schizophrenia spectrum disorders. Anomalous self-experiences were assessed by means of the Examination of Anomalous Self-Experience manual in 55 patients referred to their first adequate treatment for schizophrenia. Diagnoses, symptom severity, functioning and childhood trauma were assessed using the Structured Clinical Interview for the Positive and Negative Syndrome Scale, Premorbid Adjustment Scale, Social Functioning Scale and Childhood Trauma Questionnaire. Substance misuse was measured with the Drug Use Disorder Identification Test, and alcohol use was measured with the Alcohol Use Disorder Identification Test. Duration of untreated psychosis was measured in accordance with a standardized procedure. High levels of anomalous self-experiences are significantly associated with longer duration of untreated psychosis, an association which held after correcting for other variables associated with long duration of untreated psychosis. The field of early detection in psychosis is in need of additional clinical perspectives to make further progress. Improved understanding and assessment of anomalous self-experiences may help clinicians to detect these important phenomena and provide earlier help, and thus reduce treatment delay. © 2015 Wiley Publishing Asia Pty Ltd.

  5. Mechanism of wear and tribofilm formation with ionic liquids and ashless antiwear additives

    NASA Astrophysics Data System (ADS)

    Sharma, Vibhu

    Increasingly stringent government regulation on emissions (EPA Emissions Standard Reference Guide and latest CAFE standards requiring an average fuel economy of 54.5 mpg (combined cars and trucks) by 2025) impose significant challenges to the automotive and lubricant industries calling for the development and implementation of lower viscosity ILSAC GF-5&6 and API-CJ4&5 oils which further limit the amount of SAPS and deposits in engines. Development of additives that result in lower ash content, volatility and anti-wear property plays a crucial role in being able to reach these standards. The current industrial additive technology i.e. zinc dialkyldithiophosphate (ZDDP) forms harmful deposits on catalytic convertor due to the volatility of Zn, S and P which, impairs its functionality and consequently results in higher emission from vehicles. In this research work, ionic liquids (IL's) that are non-volatile have been studied as new generation environment friendly antiwear additives along with other ashless anti-wear additives including boron based additives to overcome the current challenges of improving the fuel efficiency and reducing the amount of hazardous emissions. The goal of this thesis work is to study the tribological performance of selected IL's and develop a comprehensive understating of IL's chemistry and its consequences to their friction and wear outcomes. As first approach, various P, S and F based ionic liquids are studied for their tribological properties by analyzing the friction and wear results generated using standard tribological experiments. Following this, advanced surface characterization techniques such as X-ray absorption near edge structure (XANES) spectroscopy, SEM, Nano-indentation, SPM techniques are used to investigate the chemical-mechanical properties of the antiwear films. Results indicate that the tribological properties of ionic liquids depend on their solubility in base oil (BO) as well as their chemical interaction with the rubbing surfaces. To address the solubility issue of IL's in BO, ILs with longer alkyl chain structure were carefully selected which helped enhance the van der waals interaction between strongly polar ILs and non-polar base oil. The interaction of IL's with the metal surfaces was examined by analyzing the chemical-mechanical properties of the antiwear films formed. Results indicate that ionic liquids do react with the steel surfaces and form a protective antiwear film composed of iron polyphosphates i.e. short to medium chain length which results in improved wear protection. In addition, soluble boron additive (SB) chemistries were blended with ionic liquids to study the synergism between these two ashless antiwear chemistries. Addition of soluble boron additive (SB) to phosphorous based IL (P_DEHP) reduces the incubation time for antiwear film formation by forming boron oxide/boron phosphate film as early as the rubbing starts and subsequently a more durable iron phosphate film is formed providing long lasting wear protection. The synergistic interaction of boron chemistry with phosphorous based ionic liquids provides superior antiwear properties while eliminating volatile elements such as Zn and S from the additive technology.

  6. Hadronic vs. electromagnetic pulse shape discrimination in CsI(Tl) for high energy physics experiments

    NASA Astrophysics Data System (ADS)

    Longo, S.; Roney, J. M.

    2018-03-01

    Pulse shape discrimination using CsI(Tl) scintillators to perform neutral hadron particle identification is explored with emphasis towards application at high energy electron-positron collider experiments. Through the analysis of the pulse shape differences between scintillation pulses from photon and hadronic energy deposits using neutron and proton data collected at TRIUMF, it is shown that the pulse shape variations observed for hadrons can be modelled using a third scintillation component for CsI(Tl), in addition to the standard fast and slow components. Techniques for computing the hadronic pulse amplitudes and shape variations are developed and it is shown that the intensity of the additional scintillation component can be computed from the ionization energy loss of the interacting particles. These pulse modelling and simulation methods are integrated with GEANT4 simulation libraries and the predicted pulse shape for CsI(Tl) crystals in a 5 × 5 array of 5 × 5 × 30 cm3 crystals is studied for hadronic showers from 0.5 and 1 GeV/c KL0 and neutron particles. Using a crystal level and cluster level approach for photon vs. hadron cluster separation we demonstrate proof-of-concept for neutral hadron detection using CsI(Tl) pulse shape discrimination in high energy electron-positron collider experiments.

  7. g-LIMIT: A Vibration Isolation System for the Microgravity Science Glovebox

    NASA Technical Reports Server (NTRS)

    Whorton, Mark S.

    1998-01-01

    For many microgravity science experiments using the Microgravity Science Glovebox (MSG), the ambient acceleration environment will exceed desirable levels. To provide a more quiescent acceleration environment, a vibration isolation system named g-LIMIT (GLovebox Integrated Microgravity Isolation Technology) is being designed. g-LIMIT is the next generation of technology developed for and demonstrated by STABLE on the USML-2 mission in October 1995. Although g-LIMIT is a sub-rack level isolation system that can be used in a variety of applications, g-LIMIT is uniquely optimized for MSG implementation. Standard MSG structural and umbilical interfaces will be used so that the isolation mount is transparent to the user with no additional accommodation requirements. g-LIMIT consists of three integrated isolator modules, each of which is comprised of a dual axis actuator, two axes of acceleration sensing, two axes of position sensing, control electronics, and data transmission capabilities in a minimum-volume package. In addition, this system provides the unique capability for measuring absolute acceleration of the experiment independent of accelerometers as a by-product of the control system and will have the capability of generating pristine accelerations to enhance experiment operations. g-LIMIT is scheduled for flight during the UF-2 mission and will be available to glovebox investigators immediately after characterization testing.

  8. 78 FR 12005 - Regulation of Fuels and Fuel Additives: 2013 Renewable Fuel Standards; Public Hearing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-21

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 80 [EPA-HQ-OAR-2012-0546; FRL-9784-4] RIN 2060-AR43 Regulation of Fuels and Fuel Additives: 2013 Renewable Fuel Standards; Public Hearing AGENCY: Environmental... Additives: 2013 Renewable Fuel Standards,'' which was published separately in the Federal Register on...

  9. 10 CFR 50.43 - Additional standards and provisions affecting class 103 licenses and certifications for...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Additional standards and provisions affecting class 103... Regulatory Approvals § 50.43 Additional standards and provisions affecting class 103 licenses and... propose nuclear reactor designs which differ significantly from light-water reactor designs that were...

  10. 10 CFR 50.43 - Additional standards and provisions affecting class 103 licenses and certifications for...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Additional standards and provisions affecting class 103... Regulatory Approvals § 50.43 Additional standards and provisions affecting class 103 licenses and... propose nuclear reactor designs which differ significantly from light-water reactor designs that were...

  11. 10 CFR 50.43 - Additional standards and provisions affecting class 103 licenses and certifications for...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Additional standards and provisions affecting class 103... Regulatory Approvals § 50.43 Additional standards and provisions affecting class 103 licenses and... propose nuclear reactor designs which differ significantly from light-water reactor designs that were...

  12. 10 CFR 50.43 - Additional standards and provisions affecting class 103 licenses and certifications for...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Additional standards and provisions affecting class 103... Regulatory Approvals § 50.43 Additional standards and provisions affecting class 103 licenses and... propose nuclear reactor designs which differ significantly from light-water reactor designs that were...

  13. CCSDS telemetry systems experience at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Carper, Richard D.; Stallings, William H., III

    1990-01-01

    NASA Goddard Space Flight Center (GSFC) designs, builds, manages, and operates science and applications spacecraft in near-earth orbit, and provides data capture, data processing, and flight control services for these spacecraft. In addition, GSFC has the responsibility of providing space-ground and ground-ground communications for near-earth orbiting spacecraft, including those of the manned spaceflight programs. The goal of reducing both the developmental and operating costs of the end-to-end information system has led the GSFC to support and participate in the standardization activities of the Consultative Committee for Space Data Systems (CCSDS), including those for packet telemetry. The environment in which such systems function is described, and the GSFC experience with CCSDS packet telemetry in the context of the Gamma-Ray Observatory project is discussed.

  14. Migration of tungsten dust in tokamaks: role of dust-wall collisions

    NASA Astrophysics Data System (ADS)

    Ratynskaia, S.; Vignitchouk, L.; Tolias, P.; Bykov, I.; Bergsåker, H.; Litnovsky, A.; den Harder, N.; Lazzaro, E.

    2013-12-01

    The modelling of a controlled tungsten dust injection experiment in TEXTOR by the dust dynamics code MIGRAINe is reported. The code, in addition to the standard dust-plasma interaction processes, also encompasses major mechanical aspects of dust-surface collisions. The use of analytical expressions for the restitution coefficients as functions of the dust radius and impact velocity allows us to account for the sticking and rebound phenomena that define which parts of the dust size distribution can migrate efficiently. The experiment provided unambiguous evidence of long-distance dust migration; artificially introduced tungsten dust particles were collected 120° toroidally away from the injection point, but also a selectivity in the permissible size of transported grains was observed. The main experimental results are reproduced by modelling.

  15. Philanthropy and service excellence: what is the connection?

    PubMed

    Haycock, Camille; Curry, Deanna; Sevilla, Xavier

    2014-01-01

    Providing person-centered care is a fundamental value and guiding philosophy for all health care delivery across Catholic Health Initiatives. Exceptional service excellence with every patient and family encounter is one way in which this value is demonstrated. The consequences of treating every person with dignity, respect, and a positive attitude can have real benefit on clinical outcomes, individual healing, health system reputation, and financial incentives. In our changing health care landscape, there are now financial motivations to improve patient satisfaction. In addition, a connection can be drawn between our relationships with patients, their experience with an organization, and the subsequent philanthropic and charitable donation to that organization. This article describes one health care system's journey toward improved patient experience through service excellence infrastructure, standard processes, and expected service behaviors.

  16. COMBINE archive and OMEX format: one file to share all information to reproduce a modeling project.

    PubMed

    Bergmann, Frank T; Adams, Richard; Moodie, Stuart; Cooper, Jonathan; Glont, Mihai; Golebiewski, Martin; Hucka, Michael; Laibe, Camille; Miller, Andrew K; Nickerson, David P; Olivier, Brett G; Rodriguez, Nicolas; Sauro, Herbert M; Scharm, Martin; Soiland-Reyes, Stian; Waltemath, Dagmar; Yvon, Florent; Le Novère, Nicolas

    2014-12-14

    With the ever increasing use of computational models in the biosciences, the need to share models and reproduce the results of published studies efficiently and easily is becoming more important. To this end, various standards have been proposed that can be used to describe models, simulations, data or other essential information in a consistent fashion. These constitute various separate components required to reproduce a given published scientific result. We describe the Open Modeling EXchange format (OMEX). Together with the use of other standard formats from the Computational Modeling in Biology Network (COMBINE), OMEX is the basis of the COMBINE Archive, a single file that supports the exchange of all the information necessary for a modeling and simulation experiment in biology. An OMEX file is a ZIP container that includes a manifest file, listing the content of the archive, an optional metadata file adding information about the archive and its content, and the files describing the model. The content of a COMBINE Archive consists of files encoded in COMBINE standards whenever possible, but may include additional files defined by an Internet Media Type. Several tools that support the COMBINE Archive are available, either as independent libraries or embedded in modeling software. The COMBINE Archive facilitates the reproduction of modeling and simulation experiments in biology by embedding all the relevant information in one file. Having all the information stored and exchanged at once also helps in building activity logs and audit trails. We anticipate that the COMBINE Archive will become a significant help for modellers, as the domain moves to larger, more complex experiments such as multi-scale models of organs, digital organisms, and bioengineering.

  17. An international marine-atmospheric {sup 222}Rn measurement intercomparison in Bermuda. Part 1: NIST calibration and methodology for standardized sample additions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colle, R.; Unterweger, M.P.; Hodge, P.A.

    1996-01-01

    As part of an international {sup 222}Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (blind) {sup 222}Rn concentrations that could be related to US national standards. The standardized sample additions were obtained with a calibrated {sup 226}Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized {sup 222}Rn activity concentrations for the intercomparisonmore » ranged from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3} (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6% to 13%. This paper describes the calibration and methodology for the standardized sample additions.« less

  18. An International Marine-Atmospheric 222Rn Measurement Intercomparison in Bermuda Part I: NIST Calibration and Methodology for Standardized Sample Additions

    PubMed Central

    Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.

    1996-01-01

    As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090

  19. Effects of azadirachtin on the development and mortality of Lutzomyia longipalpis larvae (Diptera: Psychodidae: Phlebotominae).

    PubMed

    Andrade Coelho, Claudia Alves; de Souza, Nataly Araújo; Feder, Maria Denise; da Silva, Carlos Eugênio; Garcia, Elói de Souza; Azambuja, Patricia; Gonzalez, Marcelo Salabert; Rangel, Elizabeth F

    2006-03-01

    The effects of azadirachtin A added to the standard diet on the development, mortality, and metamorphosis of Lutzomyia longipalpis Lutz & Neiva, 1912 were studied. Concentrations of 0.1, 1.0, and 10.0 microg of azadirachtin/mg of diet significantly increased larval mortality in comparison with nontreated insects. Concentrations 0.1 and 1.0 microg blocked the molt of larvae, which remained as third instars until the end of the experiment. The 10 microg/mg concentration resulted in greater molt inhibition. In this group, all insects stopped their development as second instars. Simultaneous addition of ecdysone (1 microg/mg) to the standard diet containing azadirachtin counteracted the effects of azadirachtin on mortality and inhibition of ecdysis. These results indicate that azadirachtin is a potent growth inhibitor of L. longipalpis.

  20. Rational design of gold nanoparticle toxicology assays: a question of exposure scenario, dose and experimental setup.

    PubMed

    Taylor, Ulrike; Rehbock, Christoph; Streich, Carmen; Rath, Detlef; Barcikowski, Stephan

    2014-09-01

    Many studies have evaluated the toxicity of gold nanoparticles, although reliable predictions based on these results are rare. In order to overcome this problem, this article highlights strategies to improve comparability and standardization of nanotoxicological studies. To this end, it is proposed that we should adapt the nanomaterial to the addressed exposure scenario, using ligand-free nanoparticle references in order to differentiate ligand effects from size effects. Furthermore, surface-weighted particle dosing referenced to the biologically relevant parameter (e.g., cell number or organ mass) is proposed as the gold standard. In addition, it is recommended that we should shift the focus of toxicological experiments from 'live-dead' assays to the assessment of cell function, as this strategy allows observation of bioresponses at lower doses that are more relevant for in vivo scenarios.

  1. In-situ arsenic remediation in Carson Valley, Douglas County, west-central Nevada

    USGS Publications Warehouse

    Paul, Angela P.; Maurer, Douglas K.; Stollenwerk, Kenneth G.; Welch, Alan H.

    2010-01-01

    Conventional arsenic remediation strategies primarily involve above-ground treatment that include costs involved in the disposal of sludge material. The primary advantages of in-situ remediation are that building and maintaining a large treatment facility are not necessary and that costs associated with the disposal of sludge are eliminated. A two-phase study was implemented to address the feasibility of in-situ arsenic remediation in Douglas County, Nevada. Arsenic concentrations in groundwater within Douglas County range from 1 to 85 micrograms per liter. The primary arsenic species in groundwater at greater than 250 ft from land surface is arsenite; however, in the upper 150 ft of the aquifer arsenate predominates. Where arsenite is the primary form of arsenic, the oxidation of arsenite to arsenate is necessary. The results of the first phase of this investigation indicated that arsenic concentrations can be remediated to below the drinking-water standard using aeration, chlorination, iron, and pH adjustment. Arsenic concentrations were remediated to less than 10 micrograms per liter in groundwater from the shallow and deep aquifer when iron concentrations of 3-6 milligrams per liter and pH adjustments to less than 6 were used. Because of the rapid depletion of dissolved oxygen, the secondary drinking-water standards for iron (300 micrograms per liter) and manganese (100 micrograms per liter) were exceeded during treatment. Treatment was more effective in the shallow well as indicated by a greater recovery of water meeting the arsenic standard. Laboratory and field tests were included in the second phase of this study. Laboratory column experiments using aquifer material indicated the treatment process followed during the first phase of this study will continue to work, without exceeding secondary drinking-water standards, provided that groundwater was pre-aerated and an adequate number of pore volumes treated. During the 147-day laboratory experiment, no decrease in flow through the column was observed. The primary mechanism of arsenic removal is through coprecipitation with iron oxide. Calculations based on the results of the column experiments and assuming 10 and 30 percent porosity indicated that treatment of approximately 237,000-714,000 gallons of water would be required in order to remediate arsenic concentrations to less than 10 micrograms per liter. During the first second-phase field experiment, effective injection of treated groundwater back into the aquifer was prevented due to clogging likely caused by entrained gases and the fine texture (sand, clay, and gravel) of the aquifer sediments. Because of the overflow of treated water from the injection wells, only 3,760 gallons of treated water were injected. Immediately upon terminating this first experiment, no arsenic remediation was apparent. However, approximately 24 hours after terminating the experiment arsenic concentrations in groundwater collected from one of the injection wells showed a decrease from about 30 to 15 micrograms per liter, indicating that some remediation had taken place. In agreement with the laboratory-column experiments, pre-aeration prevented the exceedence of the secondary drinking-water standards for iron and manganese. Because of complications associated with system hydraulics, no additional experiments were performed.

  2. The phenomenology of maverick dark matter

    NASA Astrophysics Data System (ADS)

    Krusberg, Zosia Anna Celina

    Astrophysical observations from galactic to cosmological scales point to a substantial non-baryonic component to the universe's total matter density. Although very little is presently known about the physical properties of dark matter, its existence offers some of the most compelling evidence for physics beyond the standard model (BSM). In the weakly interacting massive particle (WIMP) scenario, the dark matter consists of particles that possess weak-scale interactions with the particles of the standard model, offering a compelling theoretical framework that allows us to understand the relic abundance of dark matter as a natural consequence of the thermal history of the early universe. From the perspective of particle physics phenomenology, the WIMP scenario is appealing for two additional reasons. First, many theories of BSM physics contain attractive WIMP candidates. Second, the weak-scale interactions between WIMPs and standard model particles imply the possibility of detecting scatterings between relic WIMPs and detector nuclei in direct detection experiments, products of WIMP annihilations at locations throughout the galaxy in indirect detection programs, and WIMP production signals at high-energy particle colliders. In this work, we use an effective field theory approach to study model-independent dark matter phenomenology in direct detection and collider experiments. The maverick dark matter scenario is defined by an effective field theory in which the WIMP is the only new particle within the energy range accessible to the Large Hadron Collider (LHC). Although certain assumptions are necessary to keep the problem tractable, we describe our WIMP candidate generically by specifying only its spin and dominant interaction form with standard model particles. Constraints are placed on the masses and coupling constants of the maverick WIMPs using the Wilkinson Microwave Anisotropy Probe (WMAP) relic density measurement and direct detection exclusion data from both spin-independent (XENON100 and SuperCDMS) and spin-dependent (COUPP) experiments. We further study the distinguishability of maverick WIMP production signals at the Tevatron and the LHC---at its early and nominal configurations---using standard simulation packages, place constraints on maverick WIMP properties using existing collider data, and determine projected mass reaches in future data from both colliders. We find ourselves in a unique era of theoretically-motivated, high-precision dark matter searches that hold the potential to give us important insights, not only into the nature of dark matter, but also into the physics that lies beyond the standard model.

  3. pcr: an R package for quality assessment, analysis and testing of qPCR data

    PubMed Central

    Ahmed, Mahmoud

    2018-01-01

    Background Real-time quantitative PCR (qPCR) is a broadly used technique in the biomedical research. Currently, few different analysis models are used to determine the quality of data and to quantify the mRNA level across the experimental conditions. Methods We developed an R package to implement methods for quality assessment, analysis and testing qPCR data for statistical significance. Double Delta CT and standard curve models were implemented to quantify the relative expression of target genes from CT in standard qPCR control-group experiments. In addition, calculation of amplification efficiency and curves from serial dilution qPCR experiments are used to assess the quality of the data. Finally, two-group testing and linear models were used to test for significance of the difference in expression control groups and conditions of interest. Results Using two datasets from qPCR experiments, we applied different quality assessment, analysis and statistical testing in the pcr package and compared the results to the original published articles. The final relative expression values from the different models, as well as the intermediary outputs, were checked against the expected results in the original papers and were found to be accurate and reliable. Conclusion The pcr package provides an intuitive and unified interface for its main functions to allow biologist to perform all necessary steps of qPCR analysis and produce graphs in a uniform way. PMID:29576953

  4. Minimal access surgery of pediatric inguinal hernias: a review.

    PubMed

    Saranga Bharathi, Ramanathan; Arora, Manu; Baskaran, Vasudevan

    2008-08-01

    Inguinal hernia is a common problem among children, and herniotomy has been its standard of care. Laparoscopy, which gained a toehold initially in the management of pediatric inguinal hernia (PIH), has managed to steer world opinion against routine contralateral groin exploration by precise detection of contralateral patencies. Besides detection, its ability to repair simultaneously all forms of inguinal hernias (indirect, direct, combined, recurrent, and incarcerated) together with contralateral patencies has cemented its role as a viable alternative to conventional repair. Numerous minimally invasive techniques for addressing PIH have mushroomed in the past two decades. These techniques vary considerably in their approaches to the internal ring (intraperitoneal, extraperitoneal), use of ports (three, two, one), endoscopic instruments (two, one, or none), sutures (absorbable, nonabsorbable), and techniques of knotting (intracorporeal, extracorporeal). In addition to the surgeons' experience and the merits/limitations of individual techniques, it is the nature of the defect that should govern the choice of technique. The emerging techniques show a trend toward increasing use of extracorporeal knotting and diminishing use of working ports and endoscopic instruments. These favor wider adoption of minimal access surgery in addressing PIH by surgeons, irrespective of their laparoscopic skills and experience. Growing experience, wider adoption, decreasing complications, and increasing advantages favor emergence of minimal access surgery as the gold standard for the treatment of PIH in the future. This article comprehensively reviews the laparoscopic techniques of addressing PIH.

  5. Influence of pioneer vegetation on the morphodynamic evolution of a river bed

    NASA Astrophysics Data System (ADS)

    Schwarzwälder, Kordula; Cuchet, Matilde; Schlagenhauser, Mathias

    2016-04-01

    In a natural river the morphology and the evolution of the river bed is highly influenced by the vegetation in and along this river bed. To estimate these effects and influences, a pre-study was conducted in a lab-flume in the outside area of the Oskar-von-Miller-Institute of the TUM. In this flume an alternating flow regime with a change between floods and standard discharge was mimicking a natural flow regime. The experiment was started with an uniform and plane sand area were the flow regime should built a nature-like morphology. During the experiment, seeds of Alfalfa were added and the sprouting plants could influence the formation of the riverbed. The changes in the morphology were measured using photogrammetry and also a standard Kinect system. The results of the measurements shall be used as basis for a 3D numerical simulation. In addition we analyzed different plants and their sprouting behavior under different growing conditions to ensure the use of the most appropriate ones for this set-up. The experimental performance was based on the experiments of Tal and Paola 2010. Tal and Paola 2010: EARTH SURFACE PROCESSES AND LANDFORMS;Earth Surf. Process. Landforms 35, 1014-1028 (2010); Copyright Published online 9 February 2010 in Wiley InterScience; (www.interscience.wiley.com) DOI: 10.1002/esp.1908

  6. Evaluation of the Revised Lagrangian Particle Model GRAL Against Wind-Tunnel and Field Observations in the Presence of Obstacles

    NASA Astrophysics Data System (ADS)

    Oettl, Dietmar

    2015-05-01

    A revised microscale flow field model has been implemented in the Lagrangian particle model Graz Lagrangian Model (GRAL) for computing flows around obstacles. It is based on the Reynolds-averaged Navier-Stokes equations in three dimensions and the widely used standard turbulence model. Here we focus on evaluating the model regarding computed concentrations by use of a comprehensive wind-tunnel experiment with numerous combinations of building geometries, stack positions, and locations. In addition, two field experiments carried out in Denmark and in the U.S were used to evaluate the model. Further, two different formulations of the standard deviation of wind component fluctuations have also been investigated, but no clear picture could be drawn in this respect. Overall the model is able to capture several of the main features of pollutant dispersion around obstacles, but at least one future model improvement was identified for stack releases within the recirculation zone of buildings. Regulatory applications are the bread-and-butter of most GRAL users nowadays, requiring fast and robust modelling algorithms. Thus, a few simplifications have been introduced to decrease the computational time required. Although predicted concentrations for the two field experiments were found to be in good agreement with observations, shortcomings were identified regarding the extent of computed recirculation zones for the idealized wind-tunnel building geometries, with approaching flows perpendicular to building faces.

  7. Improving education in primary care: development of an online curriculum using the blended learning model.

    PubMed

    Lewin, Linda Orkin; Singh, Mamta; Bateman, Betzi L; Glover, Pamela Bligh

    2009-06-10

    Standardizing the experiences of medical students in a community preceptorship where clinical sites vary by geography and discipline can be challenging. Computer-assisted learning is prevalent in medical education and can help standardize experiences, but often is not used to its fullest advantage. A blended learning curriculum combining web-based modules with face-to-face learning can ensure students obtain core curricular principles. This course was developed and used at The Case Western Reserve University School of Medicine and its associated preceptorship sites in the greater Cleveland area. Leaders of a two-year elective continuity experience at the Case Western Reserve School of Medicine used adult learning principles to develop four interactive online modules presenting basics of office practice, difficult patient interviews, common primary care diagnoses, and disease prevention. They can be viewed at (http://casemed.case.edu/cpcp/curriculum). Students completed surveys rating the content and technical performance of each module and completed a Generalist OSCE exam at the end of the course. Participating students rated all aspects of the course highly; particularly those related to charting and direct patient care. Additionally, they scored very well on the Generalist OSCE exam. Students found the web-based modules to be valuable and to enhance their clinical learning. The blended learning model is a useful tool in designing web-based curriculum for enhancing the clinical curriculum of medical students.

  8. 40 CFR 80.1613 - Standards and other requirements for gasoline additive manufacturers and blenders.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... gasoline additive manufacturers and blenders. 80.1613 Section 80.1613 Protection of Environment... Gasoline Sulfur § 80.1613 Standards and other requirements for gasoline additive manufacturers and blenders. Gasoline additive manufacturers and blenders must meet the following requirements: (a) Gasoline additive...

  9. [Determination of heavy metals for RoHS compliance by ICP-OES spectrometry coupled with microwave extraction system].

    PubMed

    Hua, Li; Wu, Yi-Ping; An, Bing; Lai, Xiao-Wei

    2008-11-01

    The harm of heavy metals contained in electronic and electrical equipment (EEE) on environment is of high concern by human. Aiming to handle the great challenge of RoHS compliance, the determinations of trace or ultratrace chromium (Cr), cadmium (Cd), mercury (Hg) and lead (Pb) by inductively coupled plasma optical emission spectrometry (ICP-OES) was performed in the present paper, wherein, microwave extraction technology was used to prepare the sample solutions. In addition, the precision, recovery, repeatability and interference issues of this method were also discussed. The results exhibited that using the microwave extraction system to prepare samples is more quick, lossless, contamination-free in comparison with the conventional extraction methods such as dry ashing, wet-oven extraction etc. By analyzing the recoveries of these four heavy metals over different working time and wavelengths, the good recovery range between 85% and 115% showed that there was only tiny loss or contamination during the process of microwave extraction, sample introduction and ICP detection. Repeatability experiments proved that ICP plasma had a good stability during the working time and the matrix effect was small. Interference was a problem troublesome for atomic absorption spectrometry (AAS), however, the techniques of standard additions or inter-element correction (IEC) method can effectively eliminated the interferences of Ni, As, Fe etc. with the Cd determination. By employing the multi-wavelengths and two correction point methods, the issues of background curve sloping shift and spectra overlap were successfully overcome. Besides, for the determinations of trace heavy metal elements, the relative standard deviation (RSD) was less than 3% and the detection limits were less than 1 microg x L(-10 (3sigma, n = 5) for samples, standard solutions, and standard additions, which proved that ICP-OES has a good precision and high reliability. This provided a reliable technique support for electronic and electrical (EE) industries to comply with RoHS directive.

  10. Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study

    PubMed Central

    2010-01-01

    Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population. Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study). All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators. One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 ± 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p < 0.0001). The overall K between pocket size device and standard Doppler-echo was 0.67 in the pooled population (0.84 by experts and 0.58 by trainees). K was suboptimal for trainees in the eyeball evaluation of ejection fraction, left atrial dilation and right ventricular dilation. Overall sensitivity was 91% and specificity 76%. Sensitivity and specificity were lower in trainees than in experts. In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users. PMID:21110840

  11. Reading aloud: does previous trial history modulate the joint effects of stimulus quality and word frequency?

    PubMed

    O'Malley, Shannon; Besner, Derek

    2013-07-01

    No one would argue with the proposition that how we process events in the world is strongly affected by our experience. Nonetheless, recent experience (e.g., from the previous trial) is typically not considered in the analysis of timed cognitive performance in the laboratory. Masson and Kliegl (2013) reported that, in the context of the lexical decision task, the nature of the previous trial strongly modulates the joint effects of word frequency and stimulus quality-a joint effect that is widely reported to be additive when averaged over trial history. In particular, their analysis suggests there may be no genuine additivity of these factors. Here we extended this line of investigation by reanalyzing data reported by O'Malley and Besner (2008) in which subjects read words and nonwords aloud, with word frequency and stimulus quality as manipulated factors. These factors are additive on reaction time in the standard analysis of variance. Contrary to Masson and Kliegl's finding for lexical decision, when previous trial history is taken into consideration, these 2 factors still do not interact. This suggests that, at least in the context of reading aloud, previous trial does not modulate how the effects of these 2 factors combine. Some implications are briefly noted. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  12. Species Composition and Fire: Non-Additive Mixture Effects on Ground Fuel Flammability

    PubMed Central

    van Altena, Cassandra; van Logtestijn, Richard S. P.; Cornwell, William K.; Cornelissen, Johannes H. C.

    2012-01-01

    Diversity effects on many aspects of ecosystem function have been well documented. However, fire is an exception: fire experiments have mainly included single species, bulk litter, or vegetation, and, as such, the role of diversity as a determinant of flammability, a crucial aspect of ecosystem function, is poorly understood. This study is the first to experimentally test whether flammability characteristics of two-species mixtures are non-additive, i.e., differ from expected flammability based on the component species in monospecific fuel. In standardized fire experiments on ground fuels, including monospecific fuels and mixtures of five contrasting subarctic plant fuel types in a controlled laboratory environment, we measured flame speed, flame duration, and maximum temperature. Broadly half of the mixture combinations showed non-additive effects for these flammability indicators; these were mainly enhanced dominance effects for temporal dynamics – fire speed and duration. Fuel types with the more flammable value for a characteristic determined the rate of fire speed and duration of the whole mixture; in contrast, maximum temperature of the fire was determined by the biomass-weighted mean of the mixture. These results suggest that ecological invasions by highly flammable species may have effects on ground-fire dynamics well out of proportion to their biomass. PMID:22639656

  13. Application of IUS equipment and experience to orbit transfer vehicles of the 90's

    NASA Astrophysics Data System (ADS)

    Bangsund, E.; Keeney, J.; Cowgill, E.

    1985-10-01

    This paper relates experiences with the IUS program and the application of that experience to Future Orbit Transfer Vehicles. More specifically it includes the implementation of the U.S. Air Force Space Division high reliability parts standard (SMASO STD 73-2C) and the component/system test standard (MIL-STD-1540A). Test results from the parts and component level testing and the resulting system level test program for fourteen IUS flight vehicles are discussed. The IUS program has had the highest compliance with these standards and thus offers a benchmark of experience for future programs demanding extreme reliability. In summary, application of the stringent parts standard has resulted in fewer failures during testing and the stringent test standard has eliminated design problems in the hardware. Both have been expensive in costs and schedules, and should be applied with flexibility.

  14. Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

    NASA Astrophysics Data System (ADS)

    Chatzidimitriou-Dreismann, C. A.; Gray, E. MacA.; Blach, T. P.

    2012-06-01

    The "standard" procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the "standard" calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D2 in the backscattering angular range (θ>90°) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the "standard" calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present "standard" calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H2 molecules. For Case (B), some suggestions as to how the "standard" calibration could be considerably improved are made.

  15. Test sensitivity is important for detecting variability in pointing comprehension in canines.

    PubMed

    Pongrácz, Péter; Gácsi, Márta; Hegedüs, Dorottya; Péter, András; Miklósi, Adám

    2013-09-01

    Several articles have been recently published on dogs' (Canis familiaris) performance in two-way object choice experiments in which subjects had to find hidden food by utilizing human pointing. The interpretation of results has led to a vivid theoretical debate about the cognitive background of human gestural signal understanding in dogs, despite the fact that many important details of the testing method have not yet been standardized. We report three experiments that aim to reveal how some procedural differences influence adult companion dogs' performance in these tests. Utilizing a large sample in Experiment 1, we provide evidence that neither the keeping conditions (garden/house) nor the location of the testing (outdoor/indoor) affect a dogs' performance. In Experiment 2, we compare dogs' performance using three different types of pointing gestures. Dogs' performance varied between momentary distal and momentary cross-pointing but "low" and "high" performer dogs chose uniformly better than chance level if they responded to sustained pointing gestures with reinforcement (food reward and a clicking sound; "clicker pointing"). In Experiment 3, we show that single features of the aforementioned "clicker pointing" method can slightly improve dogs' success rate if they were added one by one to the momentary distal pointing method. These results provide evidence that although companion dogs show a robust performance at different testing locations regardless of their keeping conditions, the exact execution of the human gesture and additional reinforcement techniques have substantial effect on the outcomes. Consequently, researchers should standardize their methodology before engaging in debates on the comparative aspects of socio-cognitive skills because the procedures they utilize may differ in sensitivity for detecting differences.

  16. Mary Poppins was right: Adding small amounts of sugar or salt reduces the bitterness of vegetables.

    PubMed

    Bakke, Alyssa J; Stubbs, Cody A; McDowell, Elliott H; Moding, Kameron J; Johnson, Susan L; Hayes, John E

    2018-07-01

    Only a quarter of adults and 7% of children consume recommended amounts of vegetables each day. Often vegetables are not initially palatable due to bitterness, which may lead children and adults to refuse to taste or eat them. The objective of this research was to determine if very small amounts of sugar or salt (common household ingredients) could lead to significant reductions in bitterness intensity and increased hedonic ratings of green vegetable purees. For Experiment 1, three different green vegetable purees (broccoli, spinach, and kale) were prepared with different levels of sugar (0%, 0.6%, 1.2%, and 1.8%) or salt (0 and 0.2%). Samples were evaluated using standard descriptive analysis techniques with nine adults who completed more than 20 h of green vegetable specific training as a group. For Experiment 2, each vegetable puree was prepared with either 0% or 2% sugar, and bitterness was assessed via a forced choice task with 84 adults. For Experiment 3, each vegetable puree was prepared with 0%, 1%, or 2% sugar and rated for liking on standard 9 point hedonic scales by 99 adults. Experiments 1 and 2 showed that addition of small amounts of sugar and salt each reduced the bitterness (and increased sweetness and saltiness) from all three vegetables without altering other sensory properties (e.g. texture or aroma). Experiment 3 showed that adding sugar to vegetable purees increased hedonic ratings for adult consumers. We also found parents had mixed attitudes about the idea of adding sugar to foods intended for infants and toddlers. Further research on the effects of bitterness masking especially for specific populations (e.g., infants and young children or adults who have higher sensitivity to bitter taste) is warranted. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. The water treatment and recycling in 105-day bioregenerative life support experiment in the Lunar Palace 1

    NASA Astrophysics Data System (ADS)

    Xie, Beizhen; Zhu, Guorong; Liu, Bojie; Su, Qiang; Deng, Shengda; Yang, Lige; Liu, Guanghui; Dong, Chen; Wang, Minjuan; Liu, Hong

    2017-11-01

    In the bioregenerative life support system (BLSS), water recycling is one of the essential issues. The Lunar Palace 1, a ground-based bioregenerative life support system experimental facility, has been developed by our team and a 105-day closed bioregenerative life support experiment with multi-crew involved has been accomplished within this large-scale facility. During the 105-day experiment, activated carbon-absorption/ultra-filtration, membrane-biological activated carbon reactor and reduced pressure distillation technology have been used to purify the condensate water, sanitary & kitchen wastewater and urine, respectively. The results demonstrated that the combination of those technologies can achieve 100% regeneration of the water inside the Lunar Palace 1. The purified condensate water (the clean water) could meet the standards for drinking water quality in China (GB5749-2006). The treatment capacity of the membrane-biological activated carbon reactor for sanitary & kitchen wastewater could reach 150 kg/d. During the 105-d experiment, the average volume loading of the bioreactor was 0.441 kgCOD/(m3d), and the average COD removal efficiency was about 85.3%. The quality of the purified sanitary & kitchen wastewater (the greywater) could meet the standards for irrigation water quality (GB 5084-2005). In addition, during the 105-day experiment, the total excreted urine volume of three crew members was 346 L and the contained water was totally treated and recovered. The removal efficiency of ion from urine was about 88.12%. Moreover, partial nitrogen within the urine was recovered as well and the average recovery ratio was about 20.5%. The study laid a foundation for the water recycling technologies which could be used in BLSS for lunar or Mars bases.

  18. From recovery programs to recovery-oriented practice? A qualitative study of mental health professionals' experiences when facilitating a recovery-oriented rehabilitation program.

    PubMed

    Dalum, Helle Stentoft; Pedersen, Inge Kryger; Cunningham, Harry; Eplov, Lene Falgaard

    2015-12-01

    The recovery model has influenced mental health services and fostered new standards for best practice. However, knowledge about how mental health care professionals (HCPs) experience recovery-oriented programs is sparse. This paper explores HCPs' experiences when facilitating a recovery-oriented rehabilitation program. The research question is how do HCPs experience a change in their attitude and practice when applying recovery-oriented programs? This paper draws on semi-structured in-depth qualitative interviews conducted with 16 HCPs experienced in facilitating a recovery-oriented rehabilitation program in either the USA or Denmark. Three themes emerged from the HCPs' reflections on changes in attitudes and practices: "Hopeful Attitude" captures a change in the HCPs' attitude toward a more positive view on the future for clients' living with mental illness; "A New Focus in the Dialogue With Clients" thematizes how the HCPs focus more on the individual's own goal for recovery rather than disease-induced goals in the dialog with clients; "A Person-Centered Role" comprises a shift in the professional role whereby the HCPs value the client's own ideas in addition to the professional's standards. This study supports the theory of the recovery model by its empirical findings and indications that when facilitating a recovery-oriented program, HCPs experience recovery-oriented changes in their attitude toward life with mental illness, and it alters their professional practice toward a stronger focus on client's own goals during treatment. More studies are needed to further clarify how changes in HCPs' attitudes translate into changes in mental health practices. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Experience With Laser Safety In The USA--A Review

    NASA Astrophysics Data System (ADS)

    Sliney, David H.

    1986-10-01

    Following several research programs in the 1960's aimed at studying the adverse biological effects of lasers and other optical radiation sources, laser occupational exposure limits were set and general safety standards were developed. Today, the experience from laser accidents and the development of new lasers and new applications have altered the format of the exposure limits and the safety procedures. It is critically important to distinguish between different biological injury mechanisms. The biological effects of ultraviolet radiation upon the skin and eye are additive over a period of at least one workday, and require different safety procedures. The scattered UV irradiance from excimer lasers may be quite hazardous, depending upon wavelength and action spectra. Since laser technology is young, the exposure of an individual in natural sunlight must be studied to evaluate the potential for chronic effects. The safety measures necessary in the use of lasers depend upon a hazard evaluation. The appropriate control measures and alternate means of enclosure, baffling, and operational control measures are presented. Present laser safety standards are explained briefly. Eye protective techniques and eyewear are considered for a variety of sources. The optical properties of enclosure materials are also discussed.

  20. Acoustic-noise-optimized diffusion-weighted imaging.

    PubMed

    Ott, Martin; Blaimer, Martin; Grodzki, David M; Breuer, Felix A; Roesch, Julie; Dörfler, Arnd; Heismann, Björn; Jakob, Peter M

    2015-12-01

    This work was aimed at reducing acoustic noise in diffusion-weighted MR imaging (DWI) that might reach acoustic noise levels of over 100 dB(A) in clinical practice. A diffusion-weighted readout-segmented echo-planar imaging (EPI) sequence was optimized for acoustic noise by utilizing small readout segment widths to obtain low gradient slew rates and amplitudes instead of faster k-space coverage. In addition, all other gradients were optimized for low slew rates. Volunteer and patient imaging experiments were conducted to demonstrate the feasibility of the method. Acoustic noise measurements were performed and analyzed for four different DWI measurement protocols at 1.5T and 3T. An acoustic noise reduction of up to 20 dB(A) was achieved, which corresponds to a fourfold reduction in acoustic perception. The image quality was preserved at the level of a standard single-shot (ss)-EPI sequence, with a 27-54% increase in scan time. The diffusion-weighted imaging technique proposed in this study allowed a substantial reduction in the level of acoustic noise compared to standard single-shot diffusion-weighted EPI. This is expected to afford considerably more patient comfort, but a larger study would be necessary to fully characterize the subjective changes in patient experience.

  1. Updating national standards for drinking-water: a Philippine experience.

    PubMed

    Lomboy, M; Riego de Dios, J; Magtibay, B; Quizon, R; Molina, V; Fadrilan-Camacho, V; See, J; Enoveso, A; Barbosa, L; Agravante, A

    2017-04-01

    The latest version of the Philippine National Standards for Drinking-Water (PNSDW) was issued in 2007 by the Department of Health (DOH). Due to several issues and concerns, the DOH decided to make an update which is relevant and necessary to meet the needs of the stakeholders. As an output, the water quality parameters are now categorized into mandatory, primary, and secondary. The ten mandatory parameters are core parameters which all water service providers nationwide are obligated to test. These include thermotolerant coliforms or Escherichia coli, arsenic, cadmium, lead, nitrate, color, turbidity, pH, total dissolved solids, and disinfectant residual. The 55 primary parameters are site-specific and can be adopted as enforceable parameters when developing new water sources or when the existing source is at high risk of contamination. The 11 secondary parameters include operational parameters and those that affect the esthetic quality of drinking-water. In addition, the updated PNSDW include new sections: (1) reporting and interpretation of results and corrective actions; (2) emergency drinking-water parameters; (3) proposed Sustainable Development Goal parameters; and (4) standards for other drinking-water sources. The lessons learned and insights gained from the updating of standards are likewise incorporated in this paper.

  2. Constraints on non-Standard Model Higgs boson interactions in an effective Lagrangian using differential cross sections measured in the H→γγ decay channel at \\(\\sqrt{s} = 8\\) TeV with the ATLAS detector

    DOE PAGES

    Aad, G.

    2015-12-02

    The strength and tensor structure of the Higgs boson's interactions are investigated using an effective Lagrangian, which introduces additional CP-even and CP-odd interactions that lead to changes in the kinematic properties of the Higgs boson and associated jet spectra with respect to the Standard Model. We found that the parameters of the effective Lagrangian are probed using a fit to five differential cross sections previously measured by the ATLAS experiment in the H→γγ decay channel with an integrated luminosity of 20.3 fb -1 at \\(\\sqrt{s} = 8\\) TeV. In order to perform a simultaneous fit to the five distributions, themore » statistical correlations between them are determined by re-analysing the H→γγ candidate events in the proton–proton collision data. No significant deviations from the Standard Model predictions are observed and limits on the effective Lagrangian parameters are derived. These statistical correlations are made publicly available to allow for future analysis of theories with non-Standard Model interactions.« less

  3. ORNL Experience and Challenges Facing Dynamic Wireless Power Charging of EV's

    DOE PAGES

    Miller, John M.; Jones, Perry T.; Li, Jan-Mou; ...

    2015-05-21

    As visionary as dynamic, or in-motion, wireless charging of electric vehicles appears the concept is well over a century old as this paper will show. This is because the concept of magnetic induction dates back to the pioneering work of physicist Michael Faraday in the early 19th century. Today wireless power transfer (WPT) is being standardized for stationary and quasi-stationary charging of electric vehicles (EV). The Society of Automotive Engineers (SAE) has undertaken the standardization of stationary charging and will make this public during 2016. In addition to this the IEEE-SA (Standards Activities) initiated standards development for EV?s in theirmore » EVWPT working group in 2012. This study introduces the many challenges facing EVWPT in not only high power transfer to a moving vehicle and energy management at a utility scale, but communications in a vehicle to infrastructure (V2I) environment and management of high data rates, ultra-low latency, and dealing with communications loss in dense urban areas. Finally, future concepts such as guideway powering of EV?s are presented to illustrate one technical trajectory EVWPT may take.« less

  4. The impact of egocentric vs. allocentric agency attributions on the neural bases of reasoning about social rules.

    PubMed

    Canessa, Nicola; Pantaleo, Giuseppe; Crespi, Chiara; Gorini, Alessandra; Cappa, Stefano F

    2014-09-18

    We used the "standard" and "switched" social contract versions of the Wason Selection-task to investigate the neural bases of human reasoning about social rules. Both these versions typically elicit the deontically correct answer, i.e. the proper identification of the violations of a conditional obligation. Only in the standard version of the task, however, this response corresponds to the logically correct one. We took advantage of this differential adherence to logical vs. deontical accuracy to test the different predictions of logic rule-based vs. visuospatial accounts of inferential abilities in 14 participants who solved the standard and switched versions of the Selection-task during functional-Magnetic-Resonance-Imaging. Both versions activated the well known left fronto-parietal network of deductive reasoning. The standard version additionally recruited the medial parietal and right inferior parietal cortex, previously associated with mental imagery and with the adoption of egocentric vs. allocentric spatial reference frames. These results suggest that visuospatial processes encoding one's own subjective experience in social interactions may support and shape the interpretation of deductive arguments and/or the resulting inferences, thus contributing to elicit content effects in human reasoning. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Determination of Trace lead (II) by Resonance Light Scattering Based on Pb (II)-KI-MG System

    NASA Astrophysics Data System (ADS)

    Chen, Ninghua; Yang, Yingchun; Hao, Shuai; Li, Yangmin

    2018-01-01

    In pH=3.0 weak acidic solution, it is found that Pb2+ can react with I-to form [PbI4]2-, and it further reacted with MG to form ion-association complex. As a result, the new spectra of RLS appeared and their intensities enhanced greatly. Accordingly, a new method developed for the determination of Pb (II).The appropriate reaction conditions were optimized through experiments. The results show that a strong and stable resonance scattering spectra emerge at the wavelength of 338 nm. The resonance light scattering strength (ΔIRLS) has good linear relationship with the concentration of Pb (II) in the range of 0.2 μg/mL ~ 1.0 μg/mL. The detection limits (LOD) is 0.0155 μg/mL. The relative standard deviation (RSD) is 3.61% (n=11) for the determination of 0.6 μg/mL Pb (II) standard solution. And this method was successfully applied to the determination of three environmental water samples (nongfu spring, tap water, laboratory wastewater). Results illustrate that the addition standard recovery are 80%~107% with relative standard deviation (RSD) between 1.8% to 4.6%.

  6. Constraints on non-Standard Model Higgs boson interactions in an effective Lagrangian using differential cross sections measured in the H→γγ decay channel at \\(\\sqrt{s} = 8\\) TeV with the ATLAS detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aad, G.

    The strength and tensor structure of the Higgs boson's interactions are investigated using an effective Lagrangian, which introduces additional CP-even and CP-odd interactions that lead to changes in the kinematic properties of the Higgs boson and associated jet spectra with respect to the Standard Model. We found that the parameters of the effective Lagrangian are probed using a fit to five differential cross sections previously measured by the ATLAS experiment in the H→γγ decay channel with an integrated luminosity of 20.3 fb -1 at \\(\\sqrt{s} = 8\\) TeV. In order to perform a simultaneous fit to the five distributions, themore » statistical correlations between them are determined by re-analysing the H→γγ candidate events in the proton–proton collision data. No significant deviations from the Standard Model predictions are observed and limits on the effective Lagrangian parameters are derived. These statistical correlations are made publicly available to allow for future analysis of theories with non-Standard Model interactions.« less

  7. Massage Therapy and Quality of Life in Osteoarthritis of the Knee: A Qualitative Study.

    PubMed

    Ali, Ather; Rosenberger, Lisa; Weiss, Theresa R; Milak, Carl; Perlman, Adam I

    2017-06-01

     We hypothesized that participants receiving Swedish massage would experience benefits such as stress reduction and enhanced quality of life, in addition to the osteoarthritis-specific effects assessed in a randomized controlled clinical trial.  Qualitative methods were used to explore a deeper contextual understanding of participants' experiences with massage and osteoarthritis, in addition to the quantitative data collected from primary and secondary outcome measures of the dose-finding study.  Two community hospitals affiliated with academic health centers in Connecticut and New Jersey. Eighteen adults who previously participated in a dose-finding clinical trial of massage therapy for osteoarthritis of the knee.  Face-to-face and telephone interviews using a standardized interview guide. Triangulation of qualitative and quantitative data allowed for a more thorough understanding of the effects of massage therapy.  Three salient themes emerged from our analysis. Participants discussed 1) relaxation effects, 2) improved quality of life associated with receiving massage therapy, and 3) the accessibility of massage therapy in treating osteoarthritis.  Participant responses noted empowerment with an improved ability to perform activities of daily living after experiencing massage therapy. The majority of statements were consistent with their quantitative changes on standard osteoarthritis measures. Future research in pain conditions should include health-related quality of life assessments as well as outcomes related to perceived well-being, along with greater exploration of the concept of salutogenic side effects of an intervention in the context of complementary and integrative therapies. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. Quasi-experimental study designs series-paper 2: complementary approaches to advancing global health knowledge.

    PubMed

    Geldsetzer, Pascal; Fawzi, Wafaie

    2017-09-01

    Quasi-experiments have been infrequently used in the health sciences. Focusing on health systems implementation research, this article details key advantages of quasi-experiments and argues that they can complement (but not replace) randomized evaluations. Specifically, it may be possible to use a quasi-experiment to study the causal effect of an intervention that cannot feasibly be randomized or that would be unethical (e.g., because the intervention has become the standard of care) to test in a randomized controlled trial (RCT). In addition, because they usually take advantage of routinely collected data, quasi-experiments may be feasible when it is too costly (either financially or in terms of the required time) to carry out a RCT - an important advantage in research on health systems, which vary widely between settings. Nonetheless, we argue that RCTs will continue to be indispensable for implementation research because i) the assumptions needed to establish causality with a quasi-experiment are often unverifiable, ii) available data frequently do not allow for a rigorous quasi-experiment, and iii) randomized designs tend to lend themselves more to informing policy makers of causal effects prior to (or during) the full-scale rollout of an intervention than quasi-experiments. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Asymmetric responses of primary productivity to precipitation extremes: A synthesis of grassland precipitation manipulation experiments

    DOE PAGES

    Wilcox, Kevin R.; Shi, Zheng; Gherardi, Laureano A.; ...

    2017-04-02

    Climatic changes are altering Earth's hydrological cycle, resulting in altered precipitation amounts, increased interannual variability of precipitation, and more frequent extreme precipitation events. These trends will likely continue into the future, having substantial impacts on net primary productivity (NPP) and associated ecosystem services such as food production and carbon sequestration. Frequently, experimental manipulations of precipitation have linked altered precipitation regimes to changes in NPP. Yet, findings have been diverse and substantial uncertainty still surrounds generalities describing patterns of ecosystem sensitivity to altered precipitation. Additionally, we do not know whether previously observed correlations between NPP and precipitation remain accurate when precipitationmore » changes become extreme. We synthesized results from 83 case studies of experimental precipitation manipulations in grasslands worldwide. Here, we used meta-analytical techniques to search for generalities and asymmetries of aboveground NPP (ANPP) and belowground NPP (BNPP) responses to both the direction and magnitude of precipitation change. Sensitivity (i.e., productivity response standardized by the amount of precipitation change) of BNPP was similar under precipitation additions and reductions, but ANPP was more sensitive to precipitation additions than reductions; this was especially evident in drier ecosystems. Additionally, overall relationships between the magnitude of productivity responses and the magnitude of precipitation change were saturating in form. The saturating form of this relationship was likely driven by ANPP responses to very extreme precipitation increases, although there were limited studies imposing extreme precipitation change, and there was considerable variation among experiments. Finally, this highlights the importance of incorporating gradients of manipulations, ranging from extreme drought to extreme precipitation increases into future climate change experiments. Additionally, policy and land management decisions related to global change scenarios should consider how ANPP and BNPP responses may differ, and that ecosystem responses to extreme events might not be predicted from relationships found under moderate environmental changes.« less

  10. Asymmetric responses of primary productivity to precipitation extremes: A synthesis of grassland precipitation manipulation experiments.

    PubMed

    Wilcox, Kevin R; Shi, Zheng; Gherardi, Laureano A; Lemoine, Nathan P; Koerner, Sally E; Hoover, David L; Bork, Edward; Byrne, Kerry M; Cahill, James; Collins, Scott L; Evans, Sarah; Gilgen, Anna K; Holub, Petr; Jiang, Lifen; Knapp, Alan K; LeCain, Daniel; Liang, Junyi; Garcia-Palacios, Pablo; Peñuelas, Josep; Pockman, William T; Smith, Melinda D; Sun, Shanghua; White, Shannon R; Yahdjian, Laura; Zhu, Kai; Luo, Yiqi

    2017-10-01

    Climatic changes are altering Earth's hydrological cycle, resulting in altered precipitation amounts, increased interannual variability of precipitation, and more frequent extreme precipitation events. These trends will likely continue into the future, having substantial impacts on net primary productivity (NPP) and associated ecosystem services such as food production and carbon sequestration. Frequently, experimental manipulations of precipitation have linked altered precipitation regimes to changes in NPP. Yet, findings have been diverse and substantial uncertainty still surrounds generalities describing patterns of ecosystem sensitivity to altered precipitation. Additionally, we do not know whether previously observed correlations between NPP and precipitation remain accurate when precipitation changes become extreme. We synthesized results from 83 case studies of experimental precipitation manipulations in grasslands worldwide. We used meta-analytical techniques to search for generalities and asymmetries of aboveground NPP (ANPP) and belowground NPP (BNPP) responses to both the direction and magnitude of precipitation change. Sensitivity (i.e., productivity response standardized by the amount of precipitation change) of BNPP was similar under precipitation additions and reductions, but ANPP was more sensitive to precipitation additions than reductions; this was especially evident in drier ecosystems. Additionally, overall relationships between the magnitude of productivity responses and the magnitude of precipitation change were saturating in form. The saturating form of this relationship was likely driven by ANPP responses to very extreme precipitation increases, although there were limited studies imposing extreme precipitation change, and there was considerable variation among experiments. This highlights the importance of incorporating gradients of manipulations, ranging from extreme drought to extreme precipitation increases into future climate change experiments. Additionally, policy and land management decisions related to global change scenarios should consider how ANPP and BNPP responses may differ, and that ecosystem responses to extreme events might not be predicted from relationships found under moderate environmental changes. © 2017 John Wiley & Sons Ltd.

  11. Should PUS Standard Evolve?

    NASA Astrophysics Data System (ADS)

    Fourtier, Ph.; Nodet, J.; Garcia, G.

    2008-08-01

    Based on practical experience, the current paper presents position of Thales Alenia Space as a prime contractor, on the use of PUS standard. Questions have raised during past and present applications, which could be justifications for evolutions of the standard. This kind of reporting could be one of the entries for a reactivation of a working group on the PUS standard, taking into account significant experiences accumulated on diverse programs since early 2000.

  12. Accuracy and Precision in the Southern Hemisphere Additional Ozonesondes (SHADOZ) Dataset 1998-2000 in Light of the JOSIE-2000 Results

    NASA Technical Reports Server (NTRS)

    Witte, J. C.; Thompson, A. M.; Schmidlin, F. J.; Oltmans, S. J.; McPeters, R. D.; Smit, H. G. J.

    2003-01-01

    A network of 12 southern hemisphere tropical and subtropical stations in the Southern Hemisphere ADditional OZonesondes (SHADOZ) project has provided over 2000 profiles of stratospheric and tropospheric ozone since 1998. Balloon-borne electrochemical concentration cell (ECC) ozonesondes are used with standard radiosondes for pressure, temperature and relative humidity measurements. The archived data are available at:http: //croc.gsfc.nasa.gov/shadoz. In Thompson et al., accuracies and imprecisions in the SHADOZ 1998- 2000 dataset were examined using ground-based instruments and the TOMS total ozone measurement (version 7) as references. Small variations in ozonesonde technique introduced possible biases from station-to-station. SHADOZ total ozone column amounts are now compared to version 8 TOMS; discrepancies between the two datasets are reduced 2\\% on average. An evaluation of ozone variations among the stations is made using the results of a series of chamber simulations of ozone launches (JOSIE-2000, Juelich Ozonesonde Intercomparison Experiment) in which a standard reference ozone instrument was employed with the various sonde techniques used in SHADOZ. A number of variations in SHADOZ ozone data are explained when differences in solution strength, data processing and instrument type (manufacturer) are taken into account.

  13. Real life juvenile toxicity case studies: the good, the bad and the ugly.

    PubMed

    De Schaepdrijver, Luc; Rouan, Marie-Claude; Raoof, Araz; Bailey, Graham P; De Zwart, Loeckie; Monbaliu, Johan; Coogan, Timothy P; Lammens, Lieve; Coussement, Werner

    2008-09-01

    With the growing experience in the conduct of juvenile toxicity studies for multiple classes of compound, the 'case-by-case' approach has become under much more pressure. Instead, a general screen or 'standard design' is now commonly expected by regulatory authorities with more routine inclusion of neurological and reproductive assessments. Minor modifications or additions can be made to the design to address specific questions according to the class of drug or intended clinical use. This drift from a 'case-by-case' approach to a 'standard design' approach is present within certain reviewing divisions of the FDA, often requesting by default a rodent and non-rodent juvenile animal study. However, juvenile animal studies should be designed thoughtfully to fulfil a purpose based on scientific rationale, with each endpoint carefully considered in terms of practicality and interpretability of data generated. Only when using the appropriate strategy and design may juvenile studies add value by (1) identifying potential safety or pharmacokinetic issues for drugs intended for paediatric use, (2) suggesting additional clinical endpoints and (3) adding new information to the product label. As the knowledge from juvenile animal studies in various species grows, a better understanding of the significance/relevance of findings will be achieved.

  14. A design study to develop young children's understanding of multiplication and division

    NASA Astrophysics Data System (ADS)

    Bicknell, Brenda; Young-Loveridge, Jenny; Nguyen, Nhung

    2016-12-01

    This design study investigated the use of multiplication and division problems to help 5-year-old children develop an early understanding of multiplication and division. One teacher and her class of 15 5-year-old children were involved in a collaborative partnership with the researchers. The design study was conducted over two 4-week periods in May-June and October-November. The focus in this article is on three key aspects of classroom teaching: instructional tasks, the use of representations, and discourse, including the mathematics register. Results from selected pre- and post-assessment tasks within a diagnostic interview showed that there were improvements in addition and subtraction as well as multiplication and division, even though the teaching had used multiplication and division problems. Students made progress on all four operational domains, with effect sizes ranging from approximately two thirds of a standard deviation to 2 standard deviations. Most of the improvement in students' number strategies was in moving from `counting all' to `counting on' and `skip counting'. The findings challenge the idea that learning experiences in addition and subtraction should precede those in multiplication and division as suggested in some curriculum documents.

  15. A Reproducible Computerized Method for Quantitation of Capillary Density using Nailfold Capillaroscopy.

    PubMed

    Cheng, Cynthia; Lee, Chadd W; Daskalakis, Constantine

    2015-10-27

    Capillaroscopy is a non-invasive, efficient, relatively inexpensive and easy to learn methodology for directly visualizing the microcirculation. The capillaroscopy technique can provide insight into a patient's microvascular health, leading to a variety of potentially valuable dermatologic, ophthalmologic, rheumatologic and cardiovascular clinical applications. In addition, tumor growth may be dependent on angiogenesis, which can be quantitated by measuring microvessel density within the tumor. However, there is currently little to no standardization of techniques, and only one publication to date reports the reliability of a currently available, complex computer based algorithms for quantitating capillaroscopy data.(1) This paper describes a new, simpler, reliable, standardized capillary counting algorithm for quantitating nailfold capillaroscopy data. A simple, reproducible computerized capillaroscopy algorithm such as this would facilitate more widespread use of the technique among researchers and clinicians. Many researchers currently analyze capillaroscopy images by hand, promoting user fatigue and subjectivity of the results. This paper describes a novel, easy-to-use automated image processing algorithm in addition to a reproducible, semi-automated counting algorithm. This algorithm enables analysis of images in minutes while reducing subjectivity; only a minimal amount of training time (in our experience, less than 1 hr) is needed to learn the technique.

  16. A Reproducible Computerized Method for Quantitation of Capillary Density using Nailfold Capillaroscopy

    PubMed Central

    Daskalakis, Constantine

    2015-01-01

    Capillaroscopy is a non-invasive, efficient, relatively inexpensive and easy to learn methodology for directly visualizing the microcirculation. The capillaroscopy technique can provide insight into a patient’s microvascular health, leading to a variety of potentially valuable dermatologic, ophthalmologic, rheumatologic and cardiovascular clinical applications. In addition, tumor growth may be dependent on angiogenesis, which can be quantitated by measuring microvessel density within the tumor. However, there is currently little to no standardization of techniques, and only one publication to date reports the reliability of a currently available, complex computer based algorithms for quantitating capillaroscopy data.1 This paper describes a new, simpler, reliable, standardized capillary counting algorithm for quantitating nailfold capillaroscopy data. A simple, reproducible computerized capillaroscopy algorithm such as this would facilitate more widespread use of the technique among researchers and clinicians. Many researchers currently analyze capillaroscopy images by hand, promoting user fatigue and subjectivity of the results. This paper describes a novel, easy-to-use automated image processing algorithm in addition to a reproducible, semi-automated counting algorithm. This algorithm enables analysis of images in minutes while reducing subjectivity; only a minimal amount of training time (in our experience, less than 1 hr) is needed to learn the technique. PMID:26554744

  17. A comparative analysis of user preference-based and existing knowledge management systems attributes in the aerospace industry

    NASA Astrophysics Data System (ADS)

    Varghese, Nishad G.

    Knowledge management (KM) exists in various forms throughout organizations. Process documentation, training courses, and experience sharing are examples of KM activities performed daily. The goal of KM systems (KMS) is to provide a tool set which serves to standardize the creation, sharing, and acquisition of business critical information. Existing literature provides numerous examples of targeted evaluations of KMS, focusing on specific system attributes. This research serves to bridge the targeted evaluations with an industry-specific, holistic approach. The user preferences of aerospace employees in engineering and engineering-related fields were compared to profiles of existing aerospace KMS based on three attribute categories: technical features, system administration, and user experience. The results indicated there is a statistically significant difference between aerospace user preferences and existing profiles in the user experience attribute category, but no statistically significant difference in the technical features and system administration attribute categories. Additional analysis indicated in-house developed systems exhibit higher technical features and user experience ratings than commercial-off-the-self (COTS) systems.

  18. Transference effects of prior non-contingent reinforcement on the acquisition of temporal control on fixed-interval schedules.

    PubMed

    López, Florente; Menez, Marina

    2012-07-01

    In two experiments we examined the influence of response and time factors on the speed of acquisition of temporal control on FI schedules. In Experiment 1, prior exposure to FT accelerated the development of temporal control on FI schedules of the same temporal value. It was also found that the slower acquisition on FI with prior RT was similar to that of rats with prior standard training. In Experiment 2, prior exposure to FT accelerated the development of temporal control on a FI schedule with a threefold increase in temporal value. Additionally, it was found that with prior FI 30s training, acquisition of temporal control on FI 90s was even faster than with prior FT 30s. Measures of head-entries into the feeder along the experiments indicated that temporal control was already developed during the periodic but not during the non-periodic histories and that this control transferred to lever press during FI testing phase. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Optimal design of focused experiments and surveys

    NASA Astrophysics Data System (ADS)

    Curtis, Andrew

    1999-10-01

    Experiments and surveys are often performed to obtain data that constrain some previously underconstrained model. Often, constraints are most desired in a particular subspace of model space. Experiment design optimization requires that the quality of any particular design can be both quantified and then maximized. This study shows how the quality can be defined such that it depends on the amount of information that is focused in the particular subspace of interest. In addition, algorithms are presented which allow one particular focused quality measure (from the class of focused measures) to be evaluated efficiently. A subclass of focused quality measures is also related to the standard variance and resolution measures from linearized inverse theory. The theory presented here requires that the relationship between model parameters and data can be linearized around a reference model without significant loss of information. Physical and financial constraints define the space of possible experiment designs. Cross-well tomographic examples are presented, plus a strategy for survey design to maximize information about linear combinations of parameters such as bulk modulus, κ =λ+ 2μ/3.

  20. Multiple-reason decision making based on automatic processing.

    PubMed

    Glöckner, Andreas; Betsch, Tilmann

    2008-09-01

    It has been repeatedly shown that in decisions under time constraints, individuals predominantly use noncompensatory strategies rather than complex compensatory ones. The authors argue that these findings might be due not to limitations of cognitive capacity but instead to limitations of information search imposed by the commonly used experimental tool Mouselab (J. W. Payne, J. R. Bettman, & E. J. Johnson, 1988). The authors tested this assumption in 3 experiments. In the 1st experiment, information was openly presented, whereas in the 2nd experiment, the standard Mouselab program was used under different time limits. The results indicate that individuals are able to compute weighted additive decision strategies extremely quickly if information search is not restricted by the experimental procedure. In a 3rd experiment, these results were replicated using more complex decision tasks, and the major alternative explanations that individuals use more complex heuristics or that they merely encode the constellation of cues were ruled out. In sum, the findings challenge the fundaments of bounded rationality and highlight the importance of automatic processes in decision making. (c) 2008 APA, all rights reserved.

  1. Direct magnitude estimates of speech intelligibility in dysarthria: effects of a chosen standard.

    PubMed

    Weismer, Gary; Laures, Jacqueline S

    2002-06-01

    Direct magnitude estimation (DME) has been used frequently as a perceptual scaling technique in studies of the speech intelligibility of persons with speech disorders. The technique is typically used with a standard, or reference stimulus, chosen as a good exemplar of "midrange" intelligibility. In several published studies, the standard has been chosen subjectively, usually on the basis of the expertise of the investigators. The current experiment demonstrates that a fixed set of sentence-level utterances, obtained from 4 individuals with dysarthria (2 with Parkinson disease, 2 with traumatic brain injury) as well as 3 neurologically normal speakers, is scaled differently depending on the identity of the standard. Four different standards were used in the main experiment, three of which were judged qualitatively in two independent evaluations to be good exemplars of midrange intelligibility. Acoustic analyses did not reveal obvious differences between these four standards but suggested that the standard with the worst-scaled intelligibility had much poorer voice source characteristics compared to the other three standards. Results are discussed in terms of possible standardization of midrange intelligibility exemplars for DME experiments.

  2. Puerto Rican Vocational Students' Experiences Regarding Standardized Tests

    ERIC Educational Resources Information Center

    Segui, Nomara I.

    2016-01-01

    Vocational high school students are not passing state tests and are not meeting adequate yearly progress (AYP) requirements in Puerto Rico. Limited qualitative research has been conducted to examine the experiences of vocational high school students regarding mandated standardized tests. Using a qualitative case study, the experiences of Puerto…

  3. Developing Standards-Based Geography Curricular Materials from Overseas Field Experiences for K-12 Teachers

    ERIC Educational Resources Information Center

    Oberle, Alex; Palacios, Fabian Araya

    2012-01-01

    Overseas experiences provide educators with exceptional opportunities to incorporate field study, firsthand experiences, and tangible artifacts into the classroom. Despite this potential, teachers must consider curricular standards that direct how such international endeavors can be integrated. Furthermore, geography curriculum development is more…

  4. δ15N measurement of organic and inorganic substances by EA-IRMS: a speciation-dependent procedure.

    PubMed

    Gentile, Natacha; Rossi, Michel J; Delémont, Olivier; Siegwolf, Rolf T W

    2013-01-01

    Little attention has been paid so far to the influence of the chemical nature of the substance when measuring δ(15)N by elemental analysis (EA)-isotope ratio mass spectrometry (IRMS). Although the bulk nitrogen isotope analysis of organic material is not to be questioned, literature from different disciplines using IRMS provides hints that the quantitative conversion of nitrate into nitrogen presents difficulties. We observed abnormal series of δ(15)N values of laboratory standards and nitrates. These unexpected results were shown to be related to the tailing of the nitrogen peak of nitrate-containing compounds. A series of experiments were set up to investigate the cause of this phenomenon, using ammonium nitrate (NH(4)NO(3)) and potassium nitrate (KNO(3)) samples, two organic laboratory standards as well as the international secondary reference materials IAEA-N1, IAEA-N2-two ammonium sulphates [(NH(4))(2)SO(4)]-and IAEA-NO-3, a potassium nitrate. In experiment 1, we used graphite and vanadium pentoxide (V(2)O(5)) as additives to observe if they could enhance the decomposition (combustion) of nitrates. In experiment 2, we tested another elemental analyser configuration including an additional section of reduced copper in order to see whether or not the tailing could originate from an incomplete reduction process. Finally, we modified several parameters of the method and observed their influence on the peak shape, δ(15)N value and nitrogen content in weight percent of nitrogen of the target substances. We found the best results using mere thermal decomposition in helium, under exclusion of any oxygen. We show that the analytical procedure used for organic samples should not be used for nitrates because of their different chemical nature. We present the best performance given one set of sample introduction parameters for the analysis of nitrates, as well as for the ammonium sulphate IAEA-N1 and IAEA-N2 reference materials. We discuss these results considering the thermochemistry of the substances and the analytical technique itself. The results emphasise the difference in chemical nature of inorganic and organic samples, which necessarily involves distinct thermochemistry when analysed by EA-IRMS. Therefore, they should not be processed using the same analytical procedure. This clearly impacts on the way international secondary reference materials should be used for the calibration of organic laboratory standards.

  5. Safety self-efficacy and safety performance: potential antecedents and the moderation effect of standardization.

    PubMed

    Katz-Navon, Tal; Naveh, Eitan; Stern, Zvi

    2007-01-01

    The purpose of this paper is to suggest a new safety self-efficacy construct and to explore its antecedents and interaction with standardization to influence in-patient safety. The paper used a survey of 161 nurses using a self-administered questionnaire over a 14-day period in two large Israeli general hospitals. Nurses answered questions relating to four safety self-efficacy antecedents: enactive mastery experiences; managers as safety role models; verbal persuasion; and safety priority, that relate to the perceived level of standardization and safety self-efficacy. Confirmatory factor analysis was used to assess the scale's construct validity. Regression models were used to test hypotheses regarding the antecedents and influence of safety self-efficacy. Results indicate that: managers as safety role models; distributing safety information; and priority given to safety, contributed to safety self-efficacy. Additionally, standardization moderated the effects of safety self-efficacy and patient safety such that safety self-efficacy was positively associated with patient safety when standardization was low rather than high. Hospital managers should be aware of individual motivations as safety self-efficacy when evaluating the potential influence of standardization on patient safety. Theoretically, the study introduces a new safety self-efficacy concept, and captures its antecedents and influence on safety performance. Also, the study suggests safety self-efficacy as a boundary condition for the influence of standardization on safety performance. Implementing standardization in healthcare is problematic because not all processes can be standardized. In this case, self-efficacy plays an important role in securing patient safety. Hence, safety self-efficacy may serve as a "substitute-for-standardization," by promoting staff behaviors that affect patient safety.

  6. New Experiment to Measure the Electron Electric Dipole Moment

    NASA Technical Reports Server (NTRS)

    Kittle, Melanie

    2003-01-01

    An electron can possess an electric dipole moment (edm) only if time reversal symmetry (T) is violated. No edm of any particle has yet been discovered. CP-violation, equivalent to T-violation by the CPT theorem, does occur in Kaon decays and can be accounted for by the standard model. However, this mechanism leads to an electron edm d(sub e) of the order of 10(exp -38) e cm, whereas the current experimental bound on d(sub e) is about 10(exp -27) e cm. However, well-motivated extensions of the standard model such as supersymmetric theories do predict that de could be as large as the current bound. In addition, CP violation in the early universe is required to explain the preponderance of matter over anti-matter, but the exact mechanism of this CP violation is unclear. For these reasons, we are undertaking a new experimental program to determine de to an improved accuracy of 10(exp -29) e cm. Our experiment will use laser-cooled, trapped Cesium atoms to measure the atomic edm d(sub Cs) that occurs if d(sub e) is not zero. In order to do this, we will measure the energy splitting between the atoms spin states in parallel electric and magnetic fields. The signature of an edm would be a linear dependence of the splitting on the electric field E due to the interaction - d(sub Cs) dot E. Our measurement will be much more sensitive than previous measurements because atoms can be stored in the trap for tens of seconds, allowing for much narrower Zeeman resonance linewidths. Also, our method eliminates the most important systematic errors, proportional to atomic velocity, which have limited previous experiments. In this presentation, we will describe the design of our new apparatus, which is presently under construction. An important feature of our experimental apparatus is that magnetic field noise will be suppressed to a very low value of the order of 1 fT/(Hz)1/2. This requires careful attention to the Johnson noise currents in the chamber, which have not been important in previous experiments. In addition we will present estimates of the limits of the various errors that we expect for our experiment.

  7. The Role of Evidence in the Decision-Making Process of Selecting Essential Medicines in Developing Countries: The Case of Tanzania

    PubMed Central

    Mori, Amani Thomas; Kaale, Eliangiringa Amos; Ngalesoni, Frida; Norheim, Ole Frithjof; Robberstad, Bjarne

    2014-01-01

    Background Insufficient access to essential medicines is a major health challenge in developing countries. Despite the importance of Standard Treatment Guidelines and National Essential Medicine Lists in facilitating access to medicines, little is known about how they are updated. This study aims to describe the process of updating the Standard Treatment Guidelines and National Essential Medicine List in Tanzania and further examines the criteria and the underlying evidence used in decision-making. Methods This is a qualitative study in which data were collected by in-depth interviews and document reviews. Interviews were conducted with 18 key informants who were involved in updating the Standard Treatment Guidelines and National Essential Medicine List. We used a thematic content approach to analyse the data. Findings The Standard Treatment Guidelines and National Essential Medicine List was updated by committees of experts who were recruited mostly from referral hospitals and the Ministry of Health and Social Welfare. Efficacy, safety, availability and affordability were the most frequently utilised criteria in decision-making, although these were largely based on experience rather than evidence. In addition, recommendations from international guidelines and medicine promotions also influenced decision-making. Cost-effectiveness, despite being an important criterion for formulary decisions, was not utilised. Conclusions Recent decisions about the selection of essential medicines in Tanzania were made by committees of experts who largely used experience and discretionary judgement, leaving evidence with only a limited role in decision-making process. There may be several reasons for the current limited use of evidence in decision-making, but one hypothesis that remains to be explored is whether training experts in evidence-based decision-making would lead to a better and more explicit use of evidence. PMID:24416293

  8. nmrML: A Community Supported Open Data Standard for the Description, Storage, and Exchange of NMR Data.

    PubMed

    Schober, Daniel; Jacob, Daniel; Wilson, Michael; Cruz, Joseph A; Marcu, Ana; Grant, Jason R; Moing, Annick; Deborde, Catherine; de Figueiredo, Luis F; Haug, Kenneth; Rocca-Serra, Philippe; Easton, John; Ebbels, Timothy M D; Hao, Jie; Ludwig, Christian; Günther, Ulrich L; Rosato, Antonio; Klein, Matthias S; Lewis, Ian A; Luchinat, Claudio; Jones, Andrew R; Grauslys, Arturas; Larralde, Martin; Yokochi, Masashi; Kobayashi, Naohiro; Porzel, Andrea; Griffin, Julian L; Viant, Mark R; Wishart, David S; Steinbeck, Christoph; Salek, Reza M; Neumann, Steffen

    2018-01-02

    NMR is a widely used analytical technique with a growing number of repositories available. As a result, demands for a vendor-agnostic, open data format for long-term archiving of NMR data have emerged with the aim to ease and encourage sharing, comparison, and reuse of NMR data. Here we present nmrML, an open XML-based exchange and storage format for NMR spectral data. The nmrML format is intended to be fully compatible with existing NMR data for chemical, biochemical, and metabolomics experiments. nmrML can capture raw NMR data, spectral data acquisition parameters, and where available spectral metadata, such as chemical structures associated with spectral assignments. The nmrML format is compatible with pure-compound NMR data for reference spectral libraries as well as NMR data from complex biomixtures, i.e., metabolomics experiments. To facilitate format conversions, we provide nmrML converters for Bruker, JEOL and Agilent/Varian vendor formats. In addition, easy-to-use Web-based spectral viewing, processing, and spectral assignment tools that read and write nmrML have been developed. Software libraries and Web services for data validation are available for tool developers and end-users. The nmrML format has already been adopted for capturing and disseminating NMR data for small molecules by several open source data processing tools and metabolomics reference spectral libraries, e.g., serving as storage format for the MetaboLights data repository. The nmrML open access data standard has been endorsed by the Metabolomics Standards Initiative (MSI), and we here encourage user participation and feedback to increase usability and make it a successful standard.

  9. Primordial gravitational waves, precisely: the role of thermodynamics in the Standard Model

    NASA Astrophysics Data System (ADS)

    Saikawa, Ken'ichi; Shirai, Satoshi

    2018-05-01

    In this paper, we revisit the estimation of the spectrum of primordial gravitational waves originated from inflation, particularly focusing on the effect of thermodynamics in the Standard Model of particle physics. By collecting recent results of perturbative and non-perturbative analysis of thermodynamic quantities in the Standard Model, we obtain the effective degrees of freedom including the corrections due to non-trivial interaction properties of particles in the Standard Model for a wide temperature interval. The impact of such corrections on the spectrum of primordial gravitational waves as well as the damping effect due to free-streaming particles is investigated by numerically solving the evolution equation of tensor perturbations in the expanding universe. It is shown that the reevaluation of the effects of free-streaming photons and neutrinos gives rise to some additional damping features overlooked in previous studies. We also observe that the continuous nature of the QCD crossover results in a smooth spectrum for modes that reenter the horizon at around the epoch of the QCD phase transition. Furthermore, we explicitly show that the values of the effective degrees of freedom remain smaller than the commonly used value 106.75 even at temperature much higher than the critical temperature of the electroweak crossover, and that the amplitude of primordial gravitational waves at a frequency range relevant to direct detection experiments becomes Script O(1) % larger than previous estimates that do not include such corrections. This effect can be relevant to future high-sensitivity gravitational wave experiments such as ultimate DECIGO. Our results on the temperature evolution of the effective degrees of freedom are made available as tabulated data and fitting functions, which can also be used in the analysis of other cosmological relics.

  10. Plant diversity does not buffer drought effects on early-stage litter mass loss rates and microbial properties.

    PubMed

    Vogel, Anja; Eisenhauer, Nico; Weigelt, Alexandra; Scherer-Lorenzen, Michael

    2013-09-01

    Human activities are decreasing biodiversity and changing the climate worldwide. Both global change drivers have been shown to affect ecosystem functioning, but they may also act in concert in a non-additive way. We studied early-stage litter mass loss rates and soil microbial properties (basal respiration and microbial biomass) during the summer season in response to plant species richness and summer drought in a large grassland biodiversity experiment, the Jena Experiment, Germany. In line with our expectations, decreasing plant diversity and summer drought decreased litter mass loss rates and soil microbial properties. In contrast to our hypotheses, however, this was only true for mass loss of standard litter (wheat straw) used in all plots, and not for plant community-specific litter mass loss. We found no interactive effects between global change drivers, that is, drought reduced litter mass loss rates and soil microbial properties irrespective of plant diversity. High mass loss rates of plant community-specific litter and low responsiveness to drought relative to the standard litter indicate that soil microbial communities were adapted to decomposing community-specific plant litter material including lower susceptibility to dry conditions during summer months. Moreover, higher microbial enzymatic diversity at high plant diversity may have caused elevated mass loss of standard litter. Our results indicate that plant diversity loss and summer drought independently impede soil processes. However, soil decomposer communities may be highly adapted to decomposing plant community-specific litter material, even in situations of environmental stress. Results of standard litter mass loss moreover suggest that decomposer communities under diverse plant communities are able to cope with a greater variety of plant inputs possibly making them less responsive to biotic changes. © 2013 John Wiley & Sons Ltd.

  11. The role of evidence in the decision-making process of selecting essential medicines in developing countries: the case of Tanzania.

    PubMed

    Mori, Amani Thomas; Kaale, Eliangiringa Amos; Ngalesoni, Frida; Norheim, Ole Frithjof; Robberstad, Bjarne

    2014-01-01

    Insufficient access to essential medicines is a major health challenge in developing countries. Despite the importance of Standard Treatment Guidelines and National Essential Medicine Lists in facilitating access to medicines, little is known about how they are updated. This study aims to describe the process of updating the Standard Treatment Guidelines and National Essential Medicine List in Tanzania and further examines the criteria and the underlying evidence used in decision-making. This is a qualitative study in which data were collected by in-depth interviews and document reviews. Interviews were conducted with 18 key informants who were involved in updating the Standard Treatment Guidelines and National Essential Medicine List. We used a thematic content approach to analyse the data. The Standard Treatment Guidelines and National Essential Medicine List was updated by committees of experts who were recruited mostly from referral hospitals and the Ministry of Health and Social Welfare. Efficacy, safety, availability and affordability were the most frequently utilised criteria in decision-making, although these were largely based on experience rather than evidence. In addition, recommendations from international guidelines and medicine promotions also influenced decision-making. Cost-effectiveness, despite being an important criterion for formulary decisions, was not utilised. Recent decisions about the selection of essential medicines in Tanzania were made by committees of experts who largely used experience and discretionary judgement, leaving evidence with only a limited role in decision-making process. There may be several reasons for the current limited use of evidence in decision-making, but one hypothesis that remains to be explored is whether training experts in evidence-based decision-making would lead to a better and more explicit use of evidence.

  12. A Bionic Camera-Based Polarization Navigation Sensor

    PubMed Central

    Wang, Daobin; Liang, Huawei; Zhu, Hui; Zhang, Shuai

    2014-01-01

    Navigation and positioning technology is closely related to our routine life activities, from travel to aerospace. Recently it has been found that Cataglyphis (a kind of desert ant) is able to detect the polarization direction of skylight and navigate according to this information. This paper presents a real-time bionic camera-based polarization navigation sensor. This sensor has two work modes: one is a single-point measurement mode and the other is a multi-point measurement mode. An indoor calibration experiment of the sensor has been done under a beam of standard polarized light. The experiment results show that after noise reduction the accuracy of the sensor can reach up to 0.3256°. It is also compared with GPS and INS (Inertial Navigation System) in the single-point measurement mode through an outdoor experiment. Through time compensation and location compensation, the sensor can be a useful alternative to GPS and INS. In addition, the sensor also can measure the polarization distribution pattern when it works in multi-point measurement mode. PMID:25051029

  13. Striatal activation reflects urgency in perceptual decision making.

    PubMed

    van Maanen, Leendert; Fontanesi, Laura; Hawkins, Guy E; Forstmann, Birte U

    2016-10-01

    Deciding between multiple courses of action often entails an increasing need to do something as time passes - a sense of urgency. This notion of urgency is not incorporated in standard theories of speeded decision making that assume information is accumulated until a critical fixed threshold is reached. Yet, it is hypothesized in novel theoretical models of decision making. In two experiments, we investigated the behavioral and neural evidence for an "urgency signal" in human perceptual decision making. Experiment 1 found that as the duration of the decision making process increased, participants made a choice based on less evidence for the selected option. Experiment 2 replicated this finding, and additionally found that variability in this effect across participants covaried with activation in the striatum. We conclude that individual differences in susceptibility to urgency are reflected by striatal activation. By dynamically updating a response threshold, the striatum is involved in signaling urgency in humans. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. The TREK/E36 experiment at J-PARC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohl, M.; Collaboration: TREK Collaboration

    2013-11-07

    Experiment E36 is planned to run at the J-PARC K1.1BR kaon beamline in 2014-15 using a stopped kaon beam along with the TREK target and detector setup. The decay products of stopped positive kaons will be observed with a large-acceptance toroidal spectrometer capable of tracking charged particles with high resolution, combined with a photon calorimeter with large solid angle and redundant particle identification systems. With the aim to test lepton universality in the K{sub e2}/K{sub μ2} ratio with high precision, the experiment is highly sensitive to new physics beyond the Standard Model. A further goal of E36 is to searchmore » for a heavy sterile neutrino in two-body kaon decay, along with additional searches for exotic decay modes including the possibility to produce a dark photon and to observe its decay into an e{sup +}e{sup −} pair. An overview of the planned measurements with E36 will be presented.« less

  15. Auditory presentation and synchronization in Adobe Flash and HTML5/JavaScript Web experiments.

    PubMed

    Reimers, Stian; Stewart, Neil

    2016-09-01

    Substantial recent research has examined the accuracy of presentation durations and response time measurements for visually presented stimuli in Web-based experiments, with a general conclusion that accuracy is acceptable for most kinds of experiments. However, many areas of behavioral research use auditory stimuli instead of, or in addition to, visual stimuli. Much less is known about auditory accuracy using standard Web-based testing procedures. We used a millisecond-accurate Black Box Toolkit to measure the actual durations of auditory stimuli and the synchronization of auditory and visual presentation onsets. We examined the distribution of timings for 100 presentations of auditory and visual stimuli across two computers with difference specs, three commonly used browsers, and code written in either Adobe Flash or JavaScript. We also examined different coding options for attempting to synchronize the auditory and visual onsets. Overall, we found that auditory durations were very consistent, but that the lags between visual and auditory onsets varied substantially across browsers and computer systems.

  16. [Carl Arthur Scheunert's experiments on human nutrition, 1938-1943: boundary transgressions of a scientist under national socialism].

    PubMed

    Joost, Hans-Georg

    2012-01-01

    Carl Arthur Scheunert (1879-1957) was a German scientist who supervised several studies with prisoners that were designed to assess the optimal vitamin and nutrient supply, and were conducted by his associate Karl-Heinz Wagner (1911-2007) from 1938 to 1943. This contribution describes the aims, results and conclusions of Scheunert's research 1923 to 1945 in comparison with the national and international vitamin research and its consequences for public health measures. Conditions and results of the human experiments are reconstructed and compared with similar studies performed in other countries. Burden as well as health risks for the study participants are assessed. In addition, it is discussed whether general rules for human experimentation were followed (e.g. informed consent and minimizing of health risks). Although the available documents support the conclusion that no deaths or lasting injuries were caused, the experiments violated ethical standards, in particular because of the conditions in the Waldheim prison including progressive deterioration of nutrition and health.

  17. Study on effects of E-glass fiber hybrid composites enhanced with multi-walled carbon nanotubes under tensile load using full factorial design of experiments

    NASA Astrophysics Data System (ADS)

    Musthak, Md.; Madhavi, M.; Ahsanullah, F. M.

    2017-08-01

    Carbon nanotubes (CNT's) are attracting scientific and industrial interest by virtue of their outstanding characteristics. The present research problem deals with the fabrication and characterization of E-glass fiber composites enhanced by carbon nanotubes. In the present study, three factors with two levels are considered. Hence, the design is called 23 full factorial design of experiment. The process parameters considered for the present problem are weight of multi-walled carbon nanotubes, process to disperse nano-particles in resin, and orientation of woven fabric. In addition, their levels considered for the experiment are higher level (+1) and lower level (-1). Fabrication of E-glass fiber composites was carried out according to design, and the specimens were prepared with respect to the ASTM standards D3039-76 and tensile testing was performed. The results show that the nano-particulated composite plate can be manufactured by considering lower level nano-particles stirred with probe sonicator and plied-up with hybrid orientation.

  18. Mathematical Practices and Arts Integration in an Activity-Based Projective Geometry Course

    NASA Astrophysics Data System (ADS)

    Ernest, Jessica Brooke

    It is a general assumption that the mathematical activity of students in school should, at least to some degree, parallel the practices of professional mathematicians (Brown, Collins, Duguid, 1989; Moschkovich, 2013). This assumption is reflected in the Common Core State Standards (CCSSI, 2010) and National Council of Teachers of Mathematics (NCTM, 2000) standards documents. However, the practices included in these standards documents, while developed to reflect the practices of professional mathematicians, may be idealized versions of what mathematicians actually do (Moschkovich, 2013). This might lead us to question then: "What is it that mathematicians do, and what practices are not being represented in the standards documents?" In general, the creative work of mathematicians is absent from the standards and, in turn, from school mathematics curricula, much to the dismay of some mathematicians and researchers (Lockhart, 2009; Rogers, 1999). As a result, creativity is not typically being fostered in mathematics students. As a response to this lack of focus on fostering creativity (in each of the science, technology, engineering, and mathematics disciplines--the STEM disciplines), a movement to integrate the arts emerged. This movement, called the STEAM movement--introducing the letter A into the acronym STEM to signify incorporating the arts--has been gaining momentum, yet limited research has been carried out on the efficacy of integrating the arts into mathematics courses. My experiences as the co-instructor for an activity-based course focused on projective geometry led me to consider the course as a setting for investigating both mathematical practices and arts integration. In this work, I explored the mathematical practices in which students engaged while working to develop an understanding of projective geometry through group activities. Furthermore, I explored the way in which students' learning experiences were enriched through artistic engagement in the course. I discuss mathematical play and acts of imagination--two mathematical practices in which students engaged, and which emerged from a grounded theory approach to analysis of the classroom data. In addition, I discuss particular ways in which artistic engagement, including creating two mathematically inspired artistic pieces, enriched students' learning experiences in the course. The six themes I address are artistic engagement (a) fostering mathematical play, (b) giving students the opportunity to make sense of pop-up topics, (c) providing students with the opportunity to develop coordination of mathematical tools, (d) allowing students to weave their personal experiences with mathematics, (e) contributing to students' notions of the connections between mathematics and art, and (f) changing students' relationships with art.

  19. A search for a nonbiological explanation of the Viking Labeled Release life detection experiment

    NASA Technical Reports Server (NTRS)

    Levin, G. V.; Straat, P. A.

    1981-01-01

    The possibility of nonbiological reactions involving hydrogen peroxide being the source of the positive response detected by the Viking Labeled Release (LR) life detection experiment on the surface of Mars is assessed. Labeled release experiments were conducted in the LR Test Standards Module which replicates the Viking flight instrument configuration on analog Martian soils prepared to match the Viking inorganic analysis of Mars surface material to which an aqueous solution of hydrogen peroxide had been added. Getter experiments were also conducted to compare several reactions simultaneously in the presence and absence of UV radiation prior to the addition of nutrient. Hydrogen peroxide on certain analog soils is found to be capable of reproducing the kinetics and thermal information contained in the Mars data. The peroxide concentration necessary for this response, however, is shown to require a chemical stability or production rate much greater than seems likely in the Mars environment. As previous experiments have shown hydrogen peroxide to be the most likely nonbiological source of the positive LR response, it is concluded that the presence of a biological agent on Mars must not yet be ruled out.

  20. Acceleration ground test program to verify GAS payload No. 559 structure/support avionics and experiment structural integrity

    NASA Technical Reports Server (NTRS)

    Cassanto, John M.; Cassanto, Valerie A.

    1988-01-01

    Acceleration ground tests were conducted on the Get Away Special (GAS) payload 559 to verify the structural integrity of the structure/support avionics and two of the planned three flight experiments. The ITA (Integrated Test Area) Standardized Experiment Module (ISEM) structure was modified to accommodate the experiments for payload 559. The ISEM avionics consisted of a heavy duty sliver zinc power supply, three orthogonal-mounted low range microgravity accelerometers, a tri-axis high range accelerometer, a solid state recorder/programmer sequencer, and pressure and temperature sensors. The tests were conducted using the Gravitational Plant Physiology Laboratory Centrifuge of the University City Science Center in Philadelphia, PA. The launch-powered flight steady state acceleration profile of the shuttle was simulated from lift-off through jettison of the External Tank (3.0 g's). Additional tests were conducted at twice the nominal powered flight acceleration levels (6 g's) and an over-test condition of four times the powered flight loads to 12.6 g's. The present test program has demonstrated the value of conducting ground tests to verify GAS payload experiment integrity and operation before flying on the shuttle.

  1. [ELEMENTS OF A SYSTEMATIC APPROACH TO HYGIENIC REGULATION OF XENOBIOTICS].

    PubMed

    Shtabskiy, B M; Gzhegotskiy, M R; Shafran, L M

    2016-01-01

    Hygienic standardization (HS) of chemicals remains to be the one of the effective ways to ensure chemical safety of the population. At that hygienic standards (such as maximum allowable concentrations--MACs) are interrelated and aggregated into the coherent systems. Therefore, the task of the study was in establishment of the logic of inter- standard relations between the existing standards and actualization of legitimate relations of the interrelations such as MACwz/MACatm, (i.e., to systematize standards) and so as CL₅₀/MACwz (reflecting the ratio of reliability). In the suggested systemic approach the benchmark indices of the proposed HS system are the values of the MACwz. Standards for other media, including atmosphere air may be only some compartments of MACwz. The performed studies and calculations allowed to justify and implement the system approach into the practice of HS in Ukraine. There is need for further search for additional solutions in nonreachability of LC₅₀ in the experiment, justification of standards for the population in the absence of MACwz, comparison with the data of normative databases of other countries. It is necessary to introduce the value of permissible deviation from the requirements of the systemness, to embody conditions (1)-(7) into the general principle of the prohibition of greater deviation and to harmonize acting and newly introduced standards within frameworks of modern ideology and methods of HS of harmful substances. This opens up broad prospects for the new phase of HS and a significant increase in the reliability of results obtained by the various methods and in different laboratories.

  2. NASA's Earth Science Data Systems Standards Process Experiences

    NASA Technical Reports Server (NTRS)

    Ullman, Richard E.; Enloe, Yonsook

    2007-01-01

    NASA has impaneled several internal working groups to provide recommendations to NASA management on ways to evolve and improve Earth Science Data Systems. One of these working groups is the Standards Process Group (SPC). The SPG is drawn from NASA-funded Earth Science Data Systems stakeholders, and it directs a process of community review and evaluation of proposed NASA standards. The working group's goal is to promote interoperability and interuse of NASA Earth Science data through broader use of standards that have proven implementation and operational benefit to NASA Earth science by facilitating the NASA management endorsement of proposed standards. The SPC now has two years of experience with this approach to identification of standards. We will discuss real examples of the different types of candidate standards that have been proposed to NASA's Standards Process Group such as OPeNDAP's Data Access Protocol, the Hierarchical Data Format, and Open Geospatial Consortium's Web Map Server. Each of the three types of proposals requires a different sort of criteria for understanding the broad concepts of "proven implementation" and "operational benefit" in the context of NASA Earth Science data systems. We will discuss how our Standards Process has evolved with our experiences with the three candidate standards.

  3. A Progress Report to the EARTHTIME Argon Inter-Calibration Pipette System (APSI): Still Smoking from the Same Pipe

    NASA Astrophysics Data System (ADS)

    Turrin, B. D.; Swisher, C. C., III; Hemming, S. R.; Renne, P. R.; Hodges, K. V.; Van Soest, M. C.; Heizler, M. T.; Deino, A. L.

    2016-12-01

    Five of the seven 40Ar/39Ar dating labs have completed measurements of the APIS calibration gases. The APIS experiment, while being frustratingly slow, has allowed us to make major progress towards identifying the sources of the dispersion in the original EARTHTIME experiment. In addition to the traveling APIS, many labs have been testing best procedures and making improvements. As a result of the initial experiment, we have reduce the 2% dispersion in the original experiment to 3‰. The community continues to work toward the common goal of 0.1% comparability. As you may imagine we are not all of one mind, and there is still more to be done. However, we argue that at this point we have isolated three potential causes of the observed dispersion: 1) Isotopic fractionation of the Ar reference gas. This was found to occur during a loading of the pipette reservoir, highlighting the possibility that it could also happen with other reservoir or pipette loadings in other labs. Any "splitting" of the sample to reduce overall volume could also result in "procedural" isotopic fraction; 2) Pressure dependent instrumental mass fraction, which is known to occur within the ion-source. Isotopic fraction can also occur with a secondary electron multiplier detector; 3) "Time Zero" selection bias. This bias may have the largest effect on the original experiment. Because of the great differences in age of the standards, the abundances of the measures isotopes also vary, often resulting in variable gas evolution trends during mass spectrometer measurement. As a community, we continue to compare results between laboratories chronometers (i.e. U-Pb and 40Ar/39Ar). Toward this goal the Ar community would be best be served by taking similar steps as the U-Pb community, such as the development and application of a community tracer solution and the distribution of synthetic zircon. For the Ar EARTHIME community the equivalent of this would be the development of synthetic gas standards with multiple pipettes for participating labs. The EARTHIME gas standards would deliver various controlled volumes and isotopic compositions of Ar to the mass spectrometer. This would be useful for evaluating "procedural" isotopic fractionation and ion detector linearity. The APIS experiment has served as a "proof-of concept" for this.

  4. Non-Standard Interactions in propagation at the Deep Underground Neutrino Experiment

    DOE PAGES

    Coloma, Pilar

    2016-03-03

    Here, we study the sensitivity of current and future long-baseline neutrino oscillation experiments to the effects of dimension six operators affecting neutrino propagation through Earth, commonly referred to as Non-Standard Interactions (NSI). All relevant parameters entering the oscillation probabilities (standard and non-standard) are considered at once, in order to take into account possible cancellations and degeneracies between them. We find that the Deep Underground Neutrino Experiment will significantly improve over current constraints for most NSI parameters. Most notably, it will be able to rule out the so-called LMA-dark solution, still compatible with current oscillation data, and will be sensitive to off-diagonal NSI parameters at the level of ε ~more » $$ \\mathcal{O} $$ (0.05 – 0.5). We also identify two degeneracies among standard and non-standard parameters, which could be partially resolved by combining T2HK and DUNE data.« less

  5. Simultaneous measurement of sulfur and lead isotopes in sulfides using nanosecond laser ablation coupled with two multi-collector inductively coupled plasma mass spectrometers

    NASA Astrophysics Data System (ADS)

    Yuan, Honglin; Liu, Xu; Chen, Lu; Bao, Zhian; Chen, Kaiyun; Zong, Chunlei; Li, Xiao-Chun; Qiu, Johnson Wenhong

    2018-04-01

    We herein report the coupling of a nanosecond laser ablation system with a large-scale multi-collector inductively coupled plasma mass spectrometer (Nu1700 MC-ICPMS, NP-1700) and a conventional Nu Plasma II MC-ICPMS (NP-II) for the simultaneous laser ablation and determination of in situ S and Pb isotopic compositions of sulfide minerals. We found that the required aerosol distribution between the two spectrometers depended on the Pb content of the sample. For example, for a sulfide containing 100-3000 ppm Pb, the aerosol was distributed between the NP-1700 and the NP-II spectrometers in a 1:1 ratio, while for lead contents >3000 and <100 ppm, these ratios were 5:1 and 1:3, respectively. In addition, S isotopic analysis showed a pronounced matrix effect, so a matrix-matched external standard was used for standard-sample bracketing correction. The NIST NBS 977 (NBS, National Bureau of Standards; NIST, National Institute of Standards & Technology) Tl (thallium) dry aerosol internal standard and the NIST SRM 610 (SRM, standard reference material) external standard were employed to obtain accurate results for the analysis of Pb isotopes. In tandem experiments where airflow conditions were similar to those employed during stand-alone analyses, small changes in the aerosol carrier gas flow did not significantly influence the accurate determination of S and Pb isotope ratios. In addition, careful optimization of the flow ratio of the aerosol carrier (He) and makeup (Ar) gases to match stand-alone analytical conditions allowed comparable S and Pb isotope ratios to be obtained within an error of 2 s analytical uncertainties. Furthermore, the results of tandem analyses obtained using our method were consistent with those of previously reported stand-alone techniques for the S and Pb isotopes of chalcopyrite, pyrite, galena, and sphalerite, thus indicating that this method is suitable for the simultaneous analysis of S and Pb isotopes of natural sulfide minerals, and provides an effective tool to determine S and Pb isotope compositions of sulfides formed through multi-stage deposition routes.

  6. PIMMS tools for capturing metadata about simulations

    NASA Astrophysics Data System (ADS)

    Pascoe, Charlotte; Devine, Gerard; Tourte, Gregory; Pascoe, Stephen; Lawrence, Bryan; Barjat, Hannah

    2013-04-01

    PIMMS (Portable Infrastructure for the Metafor Metadata System) provides a method for consistent and comprehensive documentation of modelling activities that enables the sharing of simulation data and model configuration information. The aim of PIMMS is to package the metadata infrastructure developed by Metafor for CMIP5 so that it can be used by climate modelling groups in UK Universities. PIMMS tools capture information about simulations from the design of experiments to the implementation of experiments via simulations that run models. PIMMS uses the Metafor methodology which consists of a Common Information Model (CIM), Controlled Vocabularies (CV) and software tools. PIMMS software tools provide for the creation and consumption of CIM content via a web services infrastructure and portal developed by the ES-DOC community. PIMMS metadata integrates with the ESGF data infrastructure via the mapping of vocabularies onto ESGF facets. There are three paradigms of PIMMS metadata collection: Model Intercomparision Projects (MIPs) where a standard set of questions is asked of all models which perform standard sets of experiments. Disciplinary level metadata collection where a standard set of questions is asked of all models but experiments are specified by users. Bespoke metadata creation where the users define questions about both models and experiments. Examples will be shown of how PIMMS has been configured to suit each of these three paradigms. In each case PIMMS allows users to provide additional metadata beyond that which is asked for in an initial deployment. The primary target for PIMMS is the UK climate modelling community where it is common practice to reuse model configurations from other researchers. This culture of collaboration exists in part because climate models are very complex with many variables that can be modified. Therefore it has become common practice to begin a series of experiments by using another climate model configuration as a starting point. Usually this other configuration is provided by a researcher in the same research group or by a previous collaborator with whom there is an existing scientific relationship. Some efforts have been made at the university department level to create documentation but there is a wide diversity in the scope and purpose of this information. The consistent and comprehensive documentation enabled by PIMMS will enable the wider sharing of climate model data and configuration information. The PIMMS methodology assumes an initial effort to document standard model configurations. Once these descriptions have been created users need only describe the specific way in which their model configuration is different from the standard. Thus the documentation burden on the user is specific to the experiment they are performing and fits easily into the workflow of doing their science. PIMMS metadata is independent of data and as such is ideally suited for documenting model development. PIMMS provides a framework for sharing information about failed model configurations for which data are not kept, the negative results that don't appear in scientific literature. PIMMS is a UK project funded by JISC, The University of Reading, The University of Bristol and STFC.

  7. Including Alternative Resources in State Renewable Portfolio Standards: Current Design and Implementation Experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heeter, J.; Bird, L.

    2012-11-01

    Currently, 29 states, the District of Columbia, and Puerto Rico have instituted a renewable portfolio standard (RPS). An RPS sets a minimum threshold for how much renewable energy must be generated in a given year. Each state policy is unique, varying in percentage targets, timetables, and eligible resources. This paper examines state experience with implementing renewable portfolio standards that include energy efficiency, thermal resources, and non-renewable energy and explores compliance experience, costs, and how states evaluate, measure, and verify energy efficiency and convert thermal energy. It aims to gain insights from the experience of states for possible federal clean energymore » policy as well as to share experience and lessons for state RPS implementation.« less

  8. Chemoreception drives plastic consumption in a hard coral.

    PubMed

    Allen, Austin S; Seymour, Alexander C; Rittschof, Daniel

    2017-11-15

    The drivers behind microplastic (up to 5mm in diameter) consumption by animals are uncertain and impacts on foundational species are poorly understood. We investigated consumption of weathered, unfouled, biofouled, pre-production and microbe-free National Institute of Standards plastic by a scleractinian coral that relies on chemosensory cues for feeding. Experiment one found that corals ingested many plastic types while mostly ignoring organic-free sand, suggesting that plastic contains phagostimulents. Experiment two found that corals ingested more plastic that wasn't covered in a microbial biofilm than plastics that were biofilmed. Additionally, corals retained ~8% of ingested plastic for 24h or more and retained particles appeared stuck in corals, with consequences for energetics, pollutant toxicity and trophic transfer. The potential for chemoreception to drive plastic consumption in marine taxa has implications for conservation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Search for Rare B Meson Decays at the BABAR Experiment

    NASA Astrophysics Data System (ADS)

    Cheaib, R.; BABAR Collaboration

    2016-11-01

    b → s transitions are flavour-changing neutral current (FCNC) processes that play an important role in the search for physics beyond the Standard Model (SM). Contributions from virtual particles in the loop are predicted to deviate observables, such as the branching fraction, from their SM expectations. Using data from the BaBar experiment, we present the first search for the rare decay B + → K+ τ+τ-. The BABAR results on the measurement of the angular asymmetries of B → K* l + l -, where l = e or μ, are also reported. In addition, using a time-dependent analysis of B → K s 0π+π-γ, the mixing induced CP-asymmetry for the radiative FCNC decay, B → K s 0ργ, is measured, along with an amplitude analysis of the mKπ and mKππ spectrum.

  10. Effects of the learning assistant experience on in-service teachers' practices

    NASA Astrophysics Data System (ADS)

    Gray, Kara E.; Webb, David C.; Otero, Valerie K.

    2012-02-01

    The Colorado Learning Assistant (LA) Program serves as a content-specific supplement to standard teacher preparation programs. In addition to transforming undergraduate STEM courses, it recruits and prepares math and science majors for teaching careers by involving university STEM faculty. The research reported here compares the teaching practices of in-service teachers who participated in the LA experience as undergraduates to a comparison group of teachers who did not participate in the LA program as undergraduates but were certified to teach through the same program. We report on teachers' views of assessments and differences in their teaching practices. This analysis is based on interviews with approximately 30 teachers and observations of their classrooms throughout their induction years of teaching. This work considers how the LA program may help improve current teacher preparation models.

  11. Comment on "Most computational hydrology is not reproducible, so is it really science?" by Christopher Hutton et al.

    NASA Astrophysics Data System (ADS)

    Añel, Juan A.

    2017-03-01

    Nowadays, the majority of the scientific community is not aware of the risks and problems associated with an inadequate use of computer systems for research, mostly for reproducibility of scientific results. Such reproducibility can be compromised by the lack of clear standards and insufficient methodological description of the computational details involved in an experiment. In addition, the inappropriate application or ignorance of copyright laws can have undesirable effects on access to aspects of great importance of the design of experiments and therefore to the interpretation of results.Plain Language SummaryThis article highlights several important issues to ensure the scientific reproducibility of results within the current scientific framework, going beyond simple documentation. Several specific examples are discussed in the field of hydrological modeling.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/7167327-toxicity-reduction-industrial-effluents','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/7167327-toxicity-reduction-industrial-effluents"><span>Toxicity reduction in industrial effluents</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Not Available</p> <p>1990-01-01</p> <p>Wastewater treatment technology is undergoing a profound transformation as a result of the fundamental changes in regulations and permit requirements. Established design procedures and criteria which have served the industry well for decades are no longer useful. Toxicity reduction requirements have forced reconsideration of design standards and caused practicing environmental engineers to seek additional training in the biological sciences. Formal academic programs have not traditionally provided the cross-training between biologists and engineers which is necessary to address these issues. This book describes not only the process of identifying the toxicity problem, but also the treatment technologies which are applicable tomore » reduction or elimination of toxicity. The information provided in this book is a compilation of the experience of ECK-ENFELDER INC. in serving the environmental needs of major industry, and the experience of the individual contributors in research and consultations.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/17675115','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/17675115"><span>Integrating preventive care and nursing standardized terminologies in nursing education: a case study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Burkhart, Lisa; Sommer, Sheryl</p> <p>2007-01-01</p> <p>This study investigated the development of a community-focused curriculum integrating primary, secondary, and tertiary prevention and nursing standardized terminologies as an organizing infrastructure. This is a case study of the curriculum redesign of the Marcella Niehoff School of Nursing, Loyola University Chicago. Faculty developed a conceptual framework integrating core concepts into curriculum design, course content, and clinical applications. A coherent curriculum was designed using a community-focused approach; primary, secondary, and tertiary prevention strategies; and standardized terminologies as the organizing infrastructure to teach and apply nursing practice. The curriculum provides a meaningful correlation between the classroom and clinical experience. Students journey with their patients throughout the health care experience, applying nursing concepts using standardized terminologies. Clinical experiences provide students with the opportunity to transfer knowledge to the health experiences of patients in their care. Patient encounters, whether at the primary, secondary, or tertiary level of prevention, are used to assist students in developing critical thinking skills through the use of standardized nursing terminologies.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22736454','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22736454"><span>A standard for test reliability in group research.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ellis, Jules L</p> <p>2013-03-01</p> <p>Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1225256-compressing-inert-doublet-model','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1225256-compressing-inert-doublet-model"><span>Compressing the Inert Doublet Model</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Blinov, Nikita; Kozaczuk, Jonathan; Morrissey, David E.; ...</p> <p>2016-02-16</p> <p>The Inert Doublet Model relies on a discrete symmetry to prevent couplings of the new scalars to Standard Model fermions. We found that this stabilizes the lightest inert state, which can then contribute to the observed dark matter density. In the presence of additional approximate symmetries, the resulting spectrum of exotic scalars can be compressed. Here, we study the phenomenological and cosmological implications of this scenario. In conclusion, we derive new limits on the compressed Inert Doublet Model from LEP, and outline the prospects for exclusion and discovery of this model at dark matter experiments, the LHC, and future colliders.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/21409656-infrared-weak-corrections-strongly-interacting-gauge-boson-scattering','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/21409656-infrared-weak-corrections-strongly-interacting-gauge-boson-scattering"><span>Infrared weak corrections to strongly interacting gauge boson scattering</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Ciafaloni, Paolo; Urbano, Alfredo</p> <p>2010-04-15</p> <p>We evaluate the impact of electroweak corrections of infrared origin on strongly interacting longitudinal gauge boson scattering, calculating all-order resummed expressions at the double log level. As a working example, we consider the standard model with a heavy Higgs. At energies typical of forthcoming experiments (LHC, International Linear Collider, Compact Linear Collider), the corrections are in the 10%-40% range, with the relative sign depending on the initial state considered and on whether or not additional gauge boson emission is included. We conclude that the effect of radiative electroweak corrections should be included in the analysis of longitudinal gauge boson scattering.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/814546','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/814546"><span>Toxicological Benchmarks for Screening Potential Contaminants of Concern for Effects on Soil and Litter Invertebrates and Heterotrophic Process</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Will, M.E.</p> <p>1994-01-01</p> <p>This report presents a standard method for deriving benchmarks for the purpose of ''contaminant screening,'' performed by comparing measured ambient concentrations of chemicals. The work was performed under Work Breakdown Structure 1.4.12.2.3.04.07.02 (Activity Data Sheet 8304). In addition, this report presents sets of data concerning the effects of chemicals in soil on invertebrates and soil microbial processes, benchmarks for chemicals potentially associated with United States Department of Energy sites, and literature describing the experiments from which data were drawn for benchmark derivation.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22457413','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22457413"><span>Endovascular treatment of isolated systemic arterial supply to normal lung with coil and glue embolisation.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Anil, G; Taneja, M; Tan, A-G-S</p> <p>2012-04-01</p> <p>Surgery is the standard treatment for the extremely rare pathology of isolated anomalous systemic arterial supply to normal lung (ISSNL). We describe our experience with this anomaly in a 29-year-old male presenting with recurrent haemoptysis that was successfully treated with a combination of metallic coils and cyanoacrylate glue. In addition to contributing to the extremely limited data on endovascular therapeutic options in ISSNL, we also intend to raise the awareness among endovascular therapists of the need to be cautious ofand preserve the radiculomedullary/pial branches arising from an anomalous artery before embolising it.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27370530','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27370530"><span>Fear of Hypoglycemia in Children and Adolescents and Their Parents with Type 1 Diabetes.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Driscoll, Kimberly A; Raymond, Jennifer; Naranjo, Diana; Patton, Susana R</p> <p>2016-08-01</p> <p>Hypoglycemia is a frequent occurrence in children and adolescents with type 1 diabetes. A variety of efforts have been made to standardize the definition of hypoglycemia and to define one of its most significant psychosocial consequences-fear of hypoglycemia (FOH). In addition to documenting the experience of FOH in children and adolescents type 1 diabetes and their parents, studies have investigated the relations between FOH and glycemic control and diabetes technology use. This review provides a summary of the recent FOH literature as it applies to pediatric type 1 diabetes.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1166932','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1166932"><span>Hanford double shell waste tank corrosion studies - final report FY2014</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Wiersma, B. J.; Fuentes, R. E.; Hicks, K.</p> <p>2014-12-19</p> <p>SRNL tasks for FY14 included studies to evaluate the susceptibility of carbon steel to vapor space corrosion (VSC), liquid-air interface (LAI) corrosion, and pitting corrosion. Additionally, SRNL evaluated the susceptibility of carbon steel to pitting corrosion under buffered waste conditions, with the objective of determining the adequate amount of inhibitor (e.g., nitrite) necessary to mitigate pitting corrosion. Other CPP experiments were performed in historical waste simulants and the results were compared to previously gathered results. The results of these activities were utilized to assess the robustness of the standardized CPP protocol</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_18");'>18</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li class="active"><span>20</span></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_20 --> <div id="page_21" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li class="active"><span>21</span></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="401"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018JHEP...02..016S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018JHEP...02..016S"><span>Dark matter in E 6 Grand unification</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Schwichtenberg, Jakob</p> <p>2018-02-01</p> <p>We discuss fermionic dark matter in non-supersymmetric E 6 Grand Unification. The fundamental representation of E 6 contains, in addition to the standard model fermions, exotic fermions and we argue that one of them is a viable, interesting dark matter candidate. Its stability is guaranteed by a discrete remnant symmetry, which is an unbroken subgroup of the E 6 gauge symmetry. We compute the symmetry breaking scales and the effect of possible threshold corrections by solving the renormalization group equations numerically after imposing gauge coupling unification. Since the Yukawa couplings of the exotic and the standard model fermions have a common origin, the mass of the dark matter particles is constrained. We find a mass range of 3 · 109 GeV ≲ m DM ≲ 1 · 1013 GeV for our E 6 dark matter candidate, which is within the reach of next-generation direct detection experiments.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018RSPTA.37670275U','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018RSPTA.37670275U"><span>Challenging the standard model by high-precision comparisons of the fundamental properties of protons and antiprotons</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Ulmer, S.; Mooser, A.; Nagahama, H.; Sellner, S.; Smorra, C.</p> <p>2018-03-01</p> <p>The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge-parity-time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era. This article is part of the Theo Murphy meeting issue `Antiproton physics in the ELENA era'.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29459414','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29459414"><span>Challenging the standard model by high-precision comparisons of the fundamental properties of protons and antiprotons.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Ulmer, S; Mooser, A; Nagahama, H; Sellner, S; Smorra, C</p> <p>2018-03-28</p> <p>The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge-parity-time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era.This article is part of the Theo Murphy meeting issue 'Antiproton physics in the ELENA era'. © 2018 The Authors.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23381536','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23381536"><span>State insurance exchanges face challenges in offering standardized choices alongside innovative value-based insurance.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Corlette, Sabrina; Downs, David; Monahan, Christine H; Yondorf, Barbara</p> <p>2013-02-01</p> <p>Value-based insurance is a relatively new approach to health insurance in which financial barriers, such as copayments, are lowered for clinical services that are considered high value, while consumer cost sharing may be increased for services considered to be of uncertain value. Such plans are complex and do not easily fit into the simplified, consumer-friendly comparison tools that many state health insurance exchanges are formulating for use in 2014. Nevertheless some states and plans are attempting to strike the right balance between a streamlined health exchange shopping experience and innovative, albeit complex, benefit design that promotes value. For example, agencies administering exchanges in Vermont and Oregon are contemplating offering value-based insurance plans as an option in addition to a set of standardized plans. In the postreform environment, policy makers must find ways to present complex value-based insurance plans in a way that consumers and employers can more readily understand.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27641317','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27641317"><span>The role of counterfactual theory in causal reasoning.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Maldonado, George</p> <p>2016-10-01</p> <p>In this commentary I review the fundamentals of counterfactual theory and its role in causal reasoning in epidemiology. I consider if counterfactual theory dictates that causal questions must be framed in terms of well-defined interventions. I conclude that it does not. I hypothesize that the interventionist approach to causal inference in epidemiology stems from elevating the randomized trial design to the gold standard for thinking about causal inference. I suggest that instead the gold standard we should use for thinking about causal inference in epidemiology is the thought experiment that, for example, compares an actual disease frequency under one exposure level with a counterfactual disease frequency under a different exposure level (as discussed in Greenland and Robins (1986) and Maldonado and Greenland (2002)). I also remind us that no method should be termed "causal" unless it addresses the effect of other biases in addition to the problem of confounding. Copyright © 2016 Elsevier Inc. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26808738','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26808738"><span>On Beyond Lidocaine: Reconsidering Local Anesthetics in Tumescent Liposuction-A Critical Review.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Hsia, Henry C</p> <p>2016-02-01</p> <p>The use of tumescent solution in liposuction is now considered standard of care; however, much debate still exists regarding its ideal components, especially surrounding the inclusion of local anesthetics. This article reviews the discussion regarding the use of local anesthetics in tumescent liposuction and how it may evolve in the future. The need for local anesthetic additives in tumescent liposuction has been questioned, and the use of longer-acting agents discouraged; however, increasing number of reports in recent years have described the increasingly widespread use of tumescent anesthesia where a wetting solution is infiltrated to achieve anesthesia in an operative field for procedures other than liposuction. More high-level evidence, such as randomized controlled clinical trials, will be required; however, it should be possible to develop a useful standardized algorithm that can guide surgeons to optimize patient safety as well as patient experience.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/21325505-hyperquarks-bosonic-preon-bound-states','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/21325505-hyperquarks-bosonic-preon-bound-states"><span>Hyperquarks and bosonic preon bound states</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Schmid, Michael L.; Buchmann, Alfons J.</p> <p>2009-11-01</p> <p>In a model in which leptons, quarks, and the recently introduced hyperquarks are built up from two fundamental spin-(1/2) preons, the standard model weak gauge bosons emerge as preon bound states. In addition, the model predicts a host of new composite gauge bosons, in particular, those responsible for hyperquark and proton decay. Their presence entails a left-right symmetric extension of the standard model weak interactions and a scheme for a partial and grand unification of nongravitational interactions based on, respectively, the effective gauge groups SU(6){sub P} and SU(9){sub G}. This leads to a prediction of the Weinberg angle at lowmore » energies in good agreement with experiment. Furthermore, using evolution equations for the effective coupling strengths, we calculate the partial and grand unification scales, the hyperquark mass scale, as well as the mass and decay rate of the lightest hyperhadron.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24549740','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24549740"><span>[Innovative teleradiology network: concept and experience report].</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Kämmerer, M; Bethge, O T; Antoch, G</p> <p>2014-04-01</p> <p>(DICOM E-MAIL provides a standardized way for exchanging DICOM objects (Digital Imaging and Communications in Medicine) and further relevant patient data for the treatment context reliably and securely via encrypted e-mails. The current version of the DICOM E-MAIL standard recommendations of the"Deutsche Röntgengesellschaft" (DRG, German Röntgen Society) defines for the first time options for setting up a special directory service for the provision and distribution of communication data of all participants in a network. By using such"telephone books", networks of any size can be operated independent of the provider. Compared to a Cross-Enterprise Document Sharing (XDS) scenario, the required infrastructure is considerably less complex and quicker to realize. Critical success factors are, in addition to the technology and an effective support, that the participants themselves contribute to the further development of the network and in this way, the network approach can be practiced.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1224514','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1224514"><span>Assessment of Hexavalent Chromium Natural Attenuation for the Hanford Site 100 Area</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Truex, Michael J.; Szecsody, James E.; Qafoku, Nikolla P.</p> <p>2015-09-01</p> <p>Hexavalent chromium (Cr(VI)) plumes are present in the 100 Area at the Hanford Site. Remediation efforts are under way with objectives of restoring the groundwater to meet the drinking-water standard (48 µg/L) and protecting the Columbia River by ensuring that discharge of groundwater to the river is below the surface-water quality standard (10 µg/L). Current remedies include application of Pump-and-Treat (P&T) at the 100-D, 100-H, and 100-K Areas and Monitored Natural Attenuation (MNA) at the 100-F/IU Area. Remedy selection is still under way at the other 100 Areas. Additional information about the natural attenuation processes for Cr(VI) is important inmore » all of these cases. In this study, laboratory experiments were conducted to demonstrate and quantify natural attenuation mechanisms using 100 Area sediments and groundwater conditions.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27382525','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27382525"><span>Utilization of a New Intracranial Support Catheter as an Intermediate Aspiration Catheter in the Treatment of Acute Ischemic Stroke: Technical Report on Initial Experience.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Lozano, J Diego; Massari, Francesco; Howk, Mary C; de Macedo Rodrigues, Katyucia; Brooks, Christopher; Perras, Mary; Rex, David E; Wakhloo, Ajay K; Kühn, Anna Luisa; Puri, Ajit S</p> <p>2016-05-21</p> <p>The endovascular management of acute ischemic stroke (AIS) due to emergency large vessel occlusion (ELVO) has become the standard of care after the recent publication of landmark randomized, controlled trials. Mechanical thrombectomy, in addition to intravenous thrombolysis (within 4.5 hours when eligible), is now part of the algorithm of the standard of care when treating AIS in patients with ELVO in the anterior circulation up to six hours after symptom onset. A newly introduced device, the Arc™ intracranial support catheter (Medtronic, Irvine, USA), is specifically designed for the introduction of neurointerventional devices into the cerebral vasculature and facilitates the delivery of microcatheters into smaller, more distal intracranial vessels. This technical report describes the use of the Arc™ intracranial support catheter in the setting of AIS.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3130495','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3130495"><span>Predicting Flavonoid UGT Regioselectivity</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Jackson, Rhydon; Knisley, Debra; McIntosh, Cecilia; Pfeiffer, Phillip</p> <p>2011-01-01</p> <p>Machine learning was applied to a challenging and biologically significant protein classification problem: the prediction of avonoid UGT acceptor regioselectivity from primary sequence. Novel indices characterizing graphical models of residues were proposed and found to be widely distributed among existing amino acid indices and to cluster residues appropriately. UGT subsequences biochemically linked to regioselectivity were modeled as sets of index sequences. Several learning techniques incorporating these UGT models were compared with classifications based on standard sequence alignment scores. These techniques included an application of time series distance functions to protein classification. Time series distances defined on the index sequences were used in nearest neighbor and support vector machine classifiers. Additionally, Bayesian neural network classifiers were applied to the index sequences. The experiments identified improvements over the nearest neighbor and support vector machine classifications relying on standard alignment similarity scores, as well as strong correlations between specific subsequences and regioselectivities. PMID:21747849</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4917373','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4917373"><span>Utilization of a New Intracranial Support Catheter as an Intermediate Aspiration Catheter in the Treatment of Acute Ischemic Stroke: Technical Report on Initial Experience</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Lozano, J. Diego; Massari, Francesco; Howk, Mary C; de Macedo Rodrigues, Katyucia; Brooks, Christopher; Perras, Mary; Rex, David E; Wakhloo, Ajay K; Kühn, Anna Luisa</p> <p>2016-01-01</p> <p>The endovascular management of acute ischemic stroke (AIS) due to emergency large vessel occlusion (ELVO) has become the standard of care after the recent publication of landmark randomized, controlled trials. Mechanical thrombectomy, in addition to intravenous thrombolysis (within 4.5 hours when eligible), is now part of the algorithm of the standard of care when treating AIS in patients with ELVO in the anterior circulation up to six hours after symptom onset. A newly introduced device, the Arc™ intracranial support catheter (Medtronic, Irvine, USA), is specifically designed for the introduction of neurointerventional devices into the cerebral vasculature and facilitates the delivery of microcatheters into smaller, more distal intracranial vessels. This technical report describes the use of the Arc™ intracranial support catheter in the setting of AIS. PMID:27382525</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5829177','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5829177"><span>Challenging the standard model by high-precision comparisons of the fundamental properties of protons and antiprotons</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Mooser, A.; Nagahama, H.; Sellner, S.; Smorra, C.</p> <p>2018-01-01</p> <p>The BASE collaboration investigates the fundamental properties of protons and antiprotons, such as charge-to-mass ratios and magnetic moments, using advanced cryogenic Penning trap systems. In recent years, we performed the most precise measurement of the magnetic moments of both the proton and the antiproton, and conducted the most precise comparison of the proton-to-antiproton charge-to-mass ratio. In addition, we have set the most stringent constraint on directly measured antiproton lifetime, based on a unique reservoir trap technique. Our matter/antimatter comparison experiments provide stringent tests of the fundamental charge–parity–time invariance, which is one of the fundamental symmetries of the standard model of particle physics. This article reviews the recent achievements of BASE and gives an outlook to our physics programme in the ELENA era. This article is part of the Theo Murphy meeting issue ‘Antiproton physics in the ELENA era’. PMID:29459414</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2005EJASP2005...71E','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2005EJASP2005...71E"><span>On the Performance Evaluation of 3D Reconstruction Techniques from a Sequence of Images</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Eid, Ahmed; Farag, Aly</p> <p>2005-12-01</p> <p>The performance evaluation of 3D reconstruction techniques is not a simple problem to solve. This is not only due to the increased dimensionality of the problem but also due to the lack of standardized and widely accepted testing methodologies. This paper presents a unified framework for the performance evaluation of different 3D reconstruction techniques. This framework includes a general problem formalization, different measuring criteria, and a classification method as a first step in standardizing the evaluation process. Performance characterization of two standard 3D reconstruction techniques, stereo and space carving, is also presented. The evaluation is performed on the same data set using an image reprojection testing methodology to reduce the dimensionality of the evaluation domain. Also, different measuring strategies are presented and applied to the stereo and space carving techniques. These measuring strategies have shown consistent results in quantifying the performance of these techniques. Additional experiments are performed on the space carving technique to study the effect of the number of input images and the camera pose on its performance.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/17461091','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/17461091"><span>Performance of painted plywood and cloth Nzi traps relative to Manitoba and greenhead traps for tabanids and stable flies.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Mihok, Steve; Carlson, David A</p> <p>2007-04-01</p> <p>Experiments were conducted to adapt the cloth Nzi trap to a format suitable for fixed applications in biting fly sampling or control. Catches of tabanids [Tabanus L., Chrysops (Meigen), and Hybomitra Enderlein], and stable flies [Stomoxys calcitrans (L.)] in painted plywood traps were compared with those in standard phthalogen blue cloth traps, and in similarly painted cloth traps. The Manitoba horse fly trap and the Tabanus nigrovittatus Macquart "greenhead" box trap were used as additional standards during one tabanid season. Shiny features of traps reduced catches, e.g., paint on cloth instead of wood, or use of aluminum screening instead of netting. Nevertheless, appropriately painted plywood Nzi traps caught as many biting flies as did standard cloth Nzi traps, if paint finishes were matte, and with the use of phthalogen blue colorants. Nzi traps collected about the same tabanid fauna as the Manitoba and T. nigrovittatus traps, but with improved catches of Chrysops and Tabanus. Recommendations are provided on appropriate color matching, and selection of readily-available materials for trap construction.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24157677','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24157677"><span>Weaving the tapestry of learning: simulation, standardized patients, and virtual communities.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Holland, Brian; Landry, Karen; Mountain, Angela; Middlebrooks, Mary Alice; Heim, Deborah; Missildine, Kathy</p> <p>2013-01-01</p> <p>Using situated cognition learning theory, nursing faculty developed simulated clinical learning experiences integrating virtual communities and standardized patients. These learning experiences provide authenticity and realism not easily achieved using the individual techniques in isolation. The authors describe the process of weaving these strategies into a rich learning experience for students.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20120015639','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20120015639"><span>ACCESS: Design and Sub-System Performance</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Kaiser, Mary Elizabeth; Morris, Matthew J.; McCandliss, Stephan R.; Rasucher, Bernard J.; Kimble, Randy A.; Kruk, Jeffrey W.; Pelton, Russell; Mott, D. Brent; Wen, Hiting; Foltz, Roger; <a style="text-decoration: none; " href="javascript:void(0); " onClick="displayelement('author_20120015639'); toggleEditAbsImage('author_20120015639_show'); toggleEditAbsImage('author_20120015639_hide'); "> <img style="display:inline; width:12px; height:12px; " src="images/arrow-up.gif" width="12" height="12" border="0" alt="hide" id="author_20120015639_show"> <img style="width:12px; height:12px; display:none; " src="images/arrow-down.gif" width="12" height="12" border="0" alt="hide" id="author_20120015639_hide"></p> <p>2012-01-01</p> <p>Establishing improved spectrophotometric standards is important for a broad range of missions and is relevant to many astrophysical problems. ACCESS, "Absolute Color Calibration Experiment for Standard Stars", is a series of rocket-borne sub-orbital missions and ground-based experiments designed to enable improvements in the precision of the astrophysical flux scale through the transfer of absolute laboratory detector standards from the National Institute of Standards and Technology (NIST) to a network of stellar standards with a calibration accuracy of 1% and a spectral resolving power of 500 across the 0.35 -1.7 micrometer bandpass.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://eric.ed.gov/?q=Kurdish&pg=6&id=ED349789','ERIC'); return false;" href="https://eric.ed.gov/?q=Kurdish&pg=6&id=ED349789"><span>Standardization of National Languages. Proceedings of a Symposium on Language Standardization (Hamburg, Germany, February 2-3, 1991).</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.eric.ed.gov/ERICWebPortal/search/extended.jsp?_pageLabel=advanced">ERIC Educational Resources Information Center</a></p> <p>von Gleich, Utta, Ed.; Wolff, Ekkehard, Ed.</p> <p></p> <p>The purpose of the symposium was to exchange experiences in the standardization of national languages in different socio-cultural contexts. Examples of the strategies and results of such experiences in Africa, Latin America, and Europe were presented for discussion. Papers presented at the symposium include the following: "Language…</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25387158','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25387158"><span>A combined toxicity study of zinc oxide nanoparticles and vitamin C in food additives.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wang, Yanli; Yuan, Lulu; Yao, Chenjie; Ding, Lin; Li, Chenchen; Fang, Jie; Sui, Keke; Liu, Yuanfang; Wu, Minghong</p> <p>2014-12-21</p> <p>At present, safety evaluation standards for nanofood additives are made based on the toxic effects of a single additive. Since the size, surface properties and chemical nature influence the toxicity of nanomaterials, the toxicity may have dramatically changed when nanomaterials are used as food additives in a complex system. Herein, we investigated the combined toxicity of zinc oxide nanoparticles (ZnO NPs) and vitamin C (Vc, ascorbic acid). The results showed that Vc increased the cytotoxicity significantly compared with that of the ZnO only NPs. When the cells were exposed to ZnO NPs at a concentration less than 15 mg L(-1), or to Vc at a concentration less than 300 mg L(-1), there was no significant cytotoxicity, both in the case of gastric epithelial cell line (GES-1) and neural stem cells (NSCs). However, when 15 mg L(-1) of ZnO NPs and 300 mg L(-1) of Vc were introduced to cells together, the cell viability decreased sharply indicating significant cytotoxicity. Moreover, the significant increase in toxicity was also shown in the in vivo experiments. The dose of the ZnO NPs and Vc used in the in vivo study was calculated according to the state of food and nutrition enhancer standard. After repeated oral exposure to ZnO NPs plus Vc, the injury of the liver and kidneys in mice has been indicated by the change of these indices. These findings demonstrate that the synergistic toxicity presented in a complex system is essential for the toxicological evaluation and safety assessment of nanofood.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21292238','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21292238"><span>Kaizen method for esophagectomy patients: improved quality control, outcomes, and decreased costs.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Iannettoni, Mark D; Lynch, William R; Parekh, Kalpaj R; McLaughlin, Kelley A</p> <p>2011-04-01</p> <p>The majority of costs associated with esophagectomy are related to the initial 3 days of hospital stay requiring intensive care unit stays, ventilator support, and intraoperative time. Additional costs arise from hospital-based services. The major cost increases are related to complications associated with the procedure. We attempted to define these costs and identify expense management by streamlining care through strict adherence to patient care maps, operative standardization, and rapid discharge planning to reduce variability. Utilizing methods of Kaizen philosophy we evaluated all processes related to the entire experience of esophageal resection. This process has taken over 5 years to achieve, with quality and cost being tracked over this time period. Cost analysis included expenses related to intensive care unit, anesthesia, disposables, and hospital services. Quality improvement measures were related to intraoperative complications, in-hospital complications, and postoperative outcomes. The Institutional Review Board approved the use of anonymous data from standard clinical practice because no additional treatment was planned (observational study). Utilizing a continuous process improvement methodology, a 43% reduction in cost per case has been achieved with a significant increase in contribution margin for esophagectomy. The length of stay has been reduced from 14 days to 5. With intraoperative and postoperative standardization the leak rate has dropped from 12% to less than 3% to no leaks in our current Kaizen modification of care in our last 64 patients. Utilizing lean manufacturing techniques and continuous process evaluation we have attempted to eliminate variability, standardized the phases of care resulting in improved outcomes, decreased length of stay, and improved contribution margins. These Kaizen improvements require continuous interventions, strict adherence to care maps, and input from all levels for quality improvements. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_19");'>19</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li class="active"><span>21</span></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_21 --> <div id="page_22" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li class="active"><span>22</span></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="421"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016AMT.....9...41W','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016AMT.....9...41W"><span>Broadband cavity-enhanced absorption spectroscopy in the ultraviolet spectral region for measurements of nitrogen dioxide and formaldehyde</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Washenfelder, R. A.; Attwood, A. R.; Flores, J. M.; Zarzana, K. J.; Rudich, Y.; Brown, S. S.</p> <p>2016-01-01</p> <p>Formaldehyde (CH<i/>2O) is the most abundant aldehyde in the atmosphere, and it strongly affects photochemistry through its photolysis. We describe simultaneous measurements of CH<i/>2O and nitrogen dioxide (NO<i/>2) using broadband cavity-enhanced absorption spectroscopy in the ultraviolet spectral region. The light source consists of a continuous-wave diode laser focused into a Xenon bulb to produce a plasma that emits high-intensity, broadband light. The plasma discharge is optically filtered and coupled into a 1 m optical cavity. The reflectivity of the cavity mirrors is 0.99930 ± 0.00003 (1- reflectivity = 700 ppm loss) at 338 nm, as determined from the known Rayleigh scattering of He and zero air. This mirror reflectivity corresponds to an effective path length of 1.43 km within the 1 m cell. We measure the cavity output over the 315-350 nm spectral region using a grating monochromator and charge-coupled device array detector. We use published reference spectra with spectral fitting software to simultaneously retrieve CH<i/>2O and NO<i/>2 concentrations. Independent measurements of NO<i/>2 standard additions by broadband cavity-enhanced absorption spectroscopy and cavity ring-down spectroscopy agree within 2 % (slope for linear fit = 1.02 ± 0.03 with r<i/>2 = 0.998). Standard additions of CH<i/>2O measured by broadband cavity-enhanced absorption spectroscopy and calculated based on flow dilution are also well correlated, with r<i/>2 = 0.9998. During constant mixed additions of NO<i/>2 and CH<i/>2O, the 30 s measurement precisions (1σ) of the current configuration were 140 and 210 pptv, respectively. The current 1 min detection limit for extinction measurements at 315-350 nm provides sufficient sensitivity for measurement of trace gases in laboratory experiments and ground-based field experiments. Additionally, the instrument provides highly accurate, spectroscopically based trace gas detection that may complement higher precision techniques based on non-absolute detection methods. In addition to trace gases, this approach will be appropriate for measurements of aerosol extinction in ambient air, and this spectral region is important for characterizing the strong ultraviolet absorption by brown carbon aerosol.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1257092','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1257092"><span>Predictions for the drive capabilities of the RancheroS Flux Compression Generator into various load inductances using the Eulerian AMR Code Roxane</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Watt, Robert Gregory</p> <p></p> <p>The Ranchero Magnetic Flux Compression Generator (FCG) has been used to create current pulses in the 10-­100 MA range for driving both “static” low inductance (0.5 nH) loads1 for generator demonstration purposes and high inductance (10-­20 nH) imploding liner loads2 for ultimate use in physics experiments at very high energy density. Simulations of the standard Ranchero generator have recently shown that it had a design issue that could lead to flux trapping in the generator, and a non-­ robust predictability in its use in high energy density experiments. A re-­examination of the design concept for the standard Ranchero generator, promptedmore » by the possible appearance of an aneurism at the output glide plane, has led to a new generation of Ranchero generators designated the RancheroS (for swooped). This generator has removed the problematic output glide plane and replaced it with a region of constantly increasing diameter in the output end of the FCG cavity in which the armature is driven outward under the influence of an additional HE load not present in the original Ranchero. The resultant RancheroS generator, to be tested in LA43S-­L13, probably in early FY17, has a significantly increased initial inductance and may be able to drive a somewhat higher load inductance than the standard Ranchero. This report will use the Eulerian AMR code Roxane to study the ability of the new design to drive static loads, with a goal of providing a database corresponding to the load inductances for which the generator might be used and the anticipated peak currents such loads might produce in physics experiments. Such a database, combined with a simple analytic model of an ideal generator, where d(LI)/dt = 0, and supplemented by earlier estimates of losses in actual use of the standard Ranchero, scaled to estimate the increase in losses due to the longer current carrying perimeter in the RancheroS, can then be used to bound the expectations for the current drive one may apply to any load assembly in future experiments.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/27251827','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/27251827"><span>Is mini-laparoscopic cholecystectomy any better than the gold standard?: A comparative study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Shaikh, Haris R; Abbas, Asad; Aleem, Salik; Lakhani, Miqdad R</p> <p>2017-01-01</p> <p>Mini-laparoscopic cholecystectomy (MLC) has widened the horizons of modern laparoscopic surgery. Standard four port laparoscopic cholecystectomy (SLC), which has long been established as the "Gold Standard" for gall bladder diseases, is under reconsideration following the advent of further minimally-invasive procedures including MLC. Our study aims to provide a comparison between MLC and SLC and assesses whether MLC has any added benefits. Patients with symptomatic gall bladder disease undergoing MLC or SLC during the 2.5-month period were included in the study. Thirty-two patients underwent MLC while SLC was performed on 40 patients by the same surgeon. Data was collected prospectively and analysed retrospectively using a predesigned questionnaire. In our study, both the groups had similar age, body mass index (BMI) and gender distribution. No cases of MLC required insertion of additional ports. The mean operative time for MLC was 38.2 min (33-61 min), which is longer than SLC; but it was not statistically significant. There was no significant difference in mean operative blood loss, postoperative pain, analgesia requirement and mobilization. Patients who underwent MLC were able to return to normal activity earlier than patients undergoing SLC (P < 0.01). Our experience suggests that MLC can safely be used as an alternative to SLC. Compared to SLC, it has the added benefit of an early return to work along with excellent cosmetic results. Further large scale trials are required to prove any additional benefit of MLC.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/123541','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/123541"><span>Advisory Committee on human radiation experiments final report</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>NONE</p> <p></p> <p>When the Advisory Committee began work in April 1994 we were charged with determining whether the radiation experiments design and administration adequately met the ethical and scientific standards, including standards of informed consent, that prevailed at the time of the experiments and that exist today and also to determine the ethical and scientific standards and criteria by which it shall evaluate human radiation experiments. Although this charge seems straightforward, it is in fact difficult to determine what the appropriate standards should be for evaluating the conduct and policies of thirty or fifty years ago. First, we needed to determine themore » extent to which the standards of that time are similar to the standards of today. To the extent that there were differences we needed to determine the relative roles of each in making moral evaluations. In Chapter 1 we report what we have been able to reconstruct about government rules and policies in the 1940s and 1950s regarding human experiments. We focus primarily on the Atomic Energy Commission and the Department of Defense. In Chapter 2 we turn from a consideration of government standards to an exploration of the norms and practices of physicians and medical scientists who conducted research with human subjects during this period. Using the results of our Ethics Oral History Project, and other sources, we also examine how scientists of the time viewed their moral responsibilities to human subjects as well as how this translated into the manner in which they conducted their research.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19790024238','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19790024238"><span>Evaluation of the JPL X-band 32 element active array. [for deep space communication</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Boreham, J. F.; Postal, R. B.; Conroy, B. L.</p> <p>1979-01-01</p> <p>Tests performed on an X-band 32-element active array are described. Antenna pattern characteristics of the array were tested in its standard operating mode as well as several degraded performance modes, including failures of 1, 2, 3, 4, 8, 16, and 31 elements. Additionally, the array was characterized with the addition of a metallic shroud, and also characterized versus rf drive level and at a single off-axis electronic beamsteered position. Characterization was performed on several of the 3/4-watt, three-stage, X-band solid-state power amplifier modules. The characterization included swept amplitude response, amplitude and phase versus temperature from -20 to +60 C, and intermodulation distortion of selected modules. The array is described and conclusions and recommendations based upon the experience and results achieved are included.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018AAS...23143005M','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018AAS...23143005M"><span>The Legacy Archive for Microwave Background Data Analysis (LAMBDA)</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Miller, Nathan; LAMBDA</p> <p>2018-01-01</p> <p>The Legacy Archive for Microwave Background Data Analysis (LAMBDA) provides CMB researchers with archival data for cosmology missions, software tools, and links to other sites of interest. LAMBDA is one-stop shopping for CMB researchers. It hosts data from WMAP along with many suborbital experiments. Over the past year, LAMBDA has acquired new data from SPTpol, SPIDER and ACTPol. In addition to the primary CMB, LAMBDA also provides foreground data.LAMBDA has several ongoing efforts to provide tools for CMB researchers. These tools include a web interface for CAMB and a web interface for a CMB survey footprint database and plotting tool. Additionally, we have recently developed a Docker container with standard CMB analysis tools and demonstrations in the form of Jupyter notebooks. These containers will be publically available through Docker's container repository and the source will be available on github.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1164862','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1164862"><span>Experiment Design and Analysis Guide - Neutronics & Physics</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Misti A Lillo</p> <p>2014-06-01</p> <p>The purpose of this guide is to provide a consistent, standardized approach to performing neutronics/physics analysis for experiments inserted into the Advanced Test Reactor (ATR). This document provides neutronics/physics analysis guidance to support experiment design and analysis needs for experiments irradiated in the ATR. This guide addresses neutronics/physics analysis in support of experiment design, experiment safety, and experiment program objectives and goals. The intent of this guide is to provide a standardized approach for performing typical neutronics/physics analyses. Deviation from this guide is allowed provided that neutronics/physics analysis details are properly documented in an analysis report.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20160006368','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20160006368"><span>Planning the Unplanned Experiment: Towards Assessing the Efficacy of Standards for Safety-Critical Software</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Graydon, Patrick J.; Holloway, C. M.</p> <p>2015-01-01</p> <p>Safe use of software in safety-critical applications requires well-founded means of determining whether software is fit for such use. While software in industries such as aviation has a good safety record, little is known about whether standards for software in safety-critical applications 'work' (or even what that means). It is often (implicitly) argued that software is fit for safety-critical use because it conforms to an appropriate standard. Without knowing whether a standard works, such reliance is an experiment; without carefully collecting assessment data, that experiment is unplanned. To help plan the experiment, we organized a workshop to develop practical ideas for assessing software safety standards. In this paper, we relate and elaborate on the workshop discussion, which revealed subtle but important study design considerations and practical barriers to collecting appropriate historical data and recruiting appropriate experimental subjects. We discuss assessing standards as written and as applied, several candidate definitions for what it means for a standard to 'work,' and key assessment strategies and study techniques and the pros and cons of each. Finally, we conclude with thoughts about the kinds of research that will be required and how academia, industry, and regulators might collaborate to overcome the noted barriers.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://eric.ed.gov/?q=design+AND+concept+AND+principles&pg=7&id=EJ1113179','ERIC'); return false;" href="https://eric.ed.gov/?q=design+AND+concept+AND+principles&pg=7&id=EJ1113179"><span>Essential Conditions for Technology-Supported, Student-Centered Learning: An Analysis of Student Experiences with Math Out Loud Using the ISTE Standards for Students</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.eric.ed.gov/ERICWebPortal/search/extended.jsp?_pageLabel=advanced">ERIC Educational Resources Information Center</a></p> <p>Dondlinger, Mary Jo; McLeod, Julie; Vasinda, Sheri</p> <p>2016-01-01</p> <p>This article explores links between student experiences with technology-rich mathematics instruction and the ISTE Standards for Students. Research methods applied constructivist grounded theory to analyze data from student interviews against the ISTE Standards for Students to identify which elements of the design of this learning environment…</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2010PhDT........64P','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2010PhDT........64P"><span>The effect of instructional methodology on high school students natural sciences standardized tests scores</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Powell, P. E.</p> <p></p> <p>Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4717916','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4717916"><span>Comparison of standardized versus individualized caloric prescriptions in the nutritional rehabilitation of inpatients with anorexia nervosa</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Haynos, Ann F.; Snipes, Cassandra; Guarda, Angela; Mayer, Laurel E.; Attia, Evelyn</p> <p>2015-01-01</p> <p>Objective Sparse research informs how caloric prescriptions should be advanced during nutritional rehabilitation of inpatients with anorexia nervosa (AN). This study compared the impact of a standardized caloric increase approach, in which increases occurred on a predetermined schedule, to an individualized approach, in which increases occurred only following insufficient weight gain, on rate, pattern, and cumulative amount of weight gain and other weight restoration outcomes. Method This study followed a natural experiment design comparing AN inpatients consecutively admitted before (n = 35) and after (n = 35) an institutional change from individualized to standardized caloric prescriptions. Authors examined the impact of prescription plan on weekly weight gain in the first treatment month using multilevel modeling. Within a subsample remaining inpatient through weight restoration (n = 40), multiple regressions examined the impact of caloric prescription plan on time to weight restoration, length of hospitalization, maximum caloric prescription, discharge BMI, and incidence of activity restriction and edema. Results There were significant interactions between prescription plan and quadratic time on average weekly weight gain (p = .03) and linear time on cumulative weekly weight gain (p < .001). Under the standardized plan, patients gained in an accelerated curvilinear pattern (p = .04) and, therefore, gained cumulatively greater amounts of weight over time (p < .001). Additionally, 30% fewer patients required activity restriction under the standardized plan. Discussion Standardized caloric prescriptions may confer advantage by facilitating accelerated early weight gain and lower incidence of bed rest without increasing the incidence of refeeding syndrome. PMID:26769581</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/19071325','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/19071325"><span>Use of fractional factorial design for optimization of digestion procedures followed by multi-element determination of essential and non-essential elements in nuts using ICP-OES technique.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Momen, Awad A; Zachariadis, George A; Anthemidis, Aristidis N; Stratis, John A</p> <p>2007-01-15</p> <p>Two digestion procedures have been tested on nut samples for application in the determination of essential (Cr, Cu, Fe, Mg, Mn, Zn) and non-essential (Al, Ba, Cd, Pb) elements by inductively coupled plasma-optical emission spectrometry (ICP-OES). These included wet digestions with HNO(3)/H(2)SO(4) and HNO(3)/H(2)SO(4)/H(2)O(2). The later one is recommended for better analytes recoveries (relative error<11%). Two calibrations (aqueous standard and standard addition) procedures were studied and proved that standard addition was preferable for all analytes. Experimental designs for seven factors (HNO(3), H(2)SO(4) and H(2)O(2) volumes, digestion time, pre-digestion time, temperature of the hot plate and sample weight) were used for optimization of sample digestion procedures. For this purpose Plackett-Burman fractional factorial design, which involve eight experiments was adopted. The factors HNO(3) and H(2)O(2) volume, and the digestion time were found to be the most important parameters. The instrumental conditions were also optimized (using peanut matrix rather than aqueous standard solutions) considering radio-frequency (rf) incident power, nebulizer argon gas flow rate and sample uptake flow rate. The analytical performance, such as limits of detection (LOD<0.74mugg(-1)), precision of the overall procedures (relative standard deviation between 2.0 and 8.2%) and accuracy (relative errors between 0.4 and 11%) were assessed statistically to evaluate the developed analytical procedures. The good agreement between measured and certified values for all analytes (relative error <11%) with respect to IAEA-331 (spinach leaves) and IAEA-359 (cabbage) indicates that the developed analytical method is well suited for further studies on the fate of major elements in nuts and possibly similar matrices.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5316249','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5316249"><span>Simultaneous Spectrophotometric Determination of Rifampicin, Isoniazid and Pyrazinamide in a Single Step</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Asadpour-Zeynali, Karim; Saeb, Elhameh</p> <p>2016-01-01</p> <p>Three antituberculosis medications are investigated in this work consist of rifampicin, isoniazid and pyrazinamide. The ultra violet (UV) spectra of these compounds are overlapped, thus use of suitable chemometric methods are helpful for simultaneous spectrophotometric determination of them. A generalized version of net analyte signal standard addition method (GNASSAM) was used for determination of three antituberculosis medications as a model system. In generalized net analyte signal standard addition method only one standard solution was prepared for all analytes. This standard solution contains a mixture of all analytes of interest, and the addition of such solution to sample, causes increases in net analyte signal of each analyte which are proportional to the concentrations of analytes in added standards solution. For determination of concentration of each analyte in some synthetic mixtures, the UV spectra of pure analytes and each sample were recorded in the range of 210 nm-550 nm. The standard addition procedure was performed for each sample and the UV spectrum was recorded after each addition and finally the results were analyzed by net analyte signal method. Obtained concentrations show acceptable performance of GNASSAM in these cases. PMID:28243267</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/21428969-guenter-tulip-filter-retrieval-experience-predictors-successful-retrieval','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/21428969-guenter-tulip-filter-retrieval-experience-predictors-successful-retrieval"><span>Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu</p> <p></p> <p>We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationshipmore » correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://ntrs.nasa.gov/search.jsp?R=20050218227&hterms=incubation&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D40%26Ntt%3Dincubation','NASA-TRS'); return false;" href="https://ntrs.nasa.gov/search.jsp?R=20050218227&hterms=incubation&qs=Ntx%3Dmode%2Bmatchall%26Ntk%3DAll%26N%3D0%26No%3D40%26Ntt%3Dincubation"><span>A modular suite of hardware enabling spaceflight cell culture research</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Hoehn, Alexander; Klaus, David M.; Stodieck, Louis S.</p> <p>2004-01-01</p> <p>BioServe Space Technologies, a NASA Research Partnership Center (RPC), has developed and operated various middeck payloads launched on 23 shuttle missions since 1991 in support of commercial space biotechnology projects. Modular cell culture systems are contained within the Commercial Generic Bioprocessing Apparatus (CGBA) suite of flight-qualified hardware, compatible with Space Shuttle, SPACEHAB, Spacelab and International Space Station (ISS) EXPRESS Rack interfaces. As part of the CGBA family, the Isothermal Containment Module (ICM) incubator provides thermal control, data acquisition and experiment manipulation capabilities, including accelerometer launch detection for automated activation and thermal profiling for culture incubation and sample preservation. The ICM can accommodate up to 8 individually controlled temperature zones. Command and telemetry capabilities allow real-time downlink of data and video permitting remote payload operation and ground control synchronization. Individual cell culture experiments can be accommodated in a variety of devices ranging from 'microgravity test tubes' or standard 100 mm Petri dishes, to complex, fed-batch bioreactors with automated culture feeding, waste removal and multiple sample draws. Up to 3 levels of containment can be achieved for chemical fixative addition, and passive gas exchange can be provided through hydrophobic membranes. Many additional options exist for designing customized hardware depending on specific science requirements.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/1814184','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/1814184"><span>Effect of evening primrose oil as food supplement on reproduction in the blue fox.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Tauson, A H; Forsberg, M</p> <p>1991-01-01</p> <p>Addition of evening primrose oil (EPO) to a blue fox diet in the reproduction period was evaluated in an experiment with 2 groups, each of 12 male and 25 female blue foxes, regarding the effects on reproductive performance. The experiment was carried out as a field trial and the experimental period lasted from March 10 until the end of the mating season (males) or early July (females). During this period the control group was fed the standard diet of the farm and the experimental group was fed the same diet supplemented with 4.5 g EPO and 2.5 mg zinc sulphate per animal and day. An addition of 10 mg vitamin E per 500 mg EPO was made. The results were evaluated regarding male and female treatment effects. There was an increased rate of abortions in the EPO-group, but simultaneously a non-significant decrease in the frequency of barren females, resulting in a similar level of females without litters in both groups. A tendency for increased litter size in the EPO group was found, mainly as an effect of male treatment, which might indicate an effect on semen quality.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016EGUGA..1814776P','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016EGUGA..1814776P"><span>Calibration of ground-based microwave radiometers - Accuracy assessment and recommendations for network users</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Pospichal, Bernhard; Küchler, Nils; Löhnert, Ulrich; Crewell, Susanne; Czekala, Harald; Güldner, Jürgen</p> <p>2016-04-01</p> <p>Ground-based microwave radiometers (MWR) are becoming widely used in atmospheric remote sensing and start to be routinely operated by national weather services and other institutions. However, common standards for calibration of these radiometers and a detailed knowledge about the error characteristics is needed, in order to assimilate the data into models. Intercomparisons of calibrations by different MWRs have rarely been done. Therefore, two calibration experiments in Lindenberg (2014) and Meckenheim (2015) were performed in the frame of TOPROF (Cost action ES1303) in order to assess uncertainties and differences between various instruments. In addition, a series of experiments were taken in Oklahoma in autumn 2014. The focus lay on the performance of the two main instrument types, which are currently used operationally. These are the MP-Profiler series by Radiometrics Corporation as well as the HATPRO series by Radiometer Physics GmbH (RPG). Both instrument types are operating in two frequency bands, one along the 22 GHz water vapour line, the other one at the lower wing of the 60 GHz oxygen absorption complex. The goal was to establish protocols for providing quality controlled (QC) MWR data and their uncertainties. To this end, standardized calibration procedures for MWR were developed and recommendations for radiometer users were compiled. We focus here mainly on data types, integration times and optimal settings for calibration intervals, both for absolute (liquid nitrogen, tipping curve) as well as relative (hot load, noise diode) calibrations. Besides the recommendations for ground-based MWR operators, we will present methods to determine the accuracy of the calibration as well as means for automatic data quality control. In addition, some results from the intercomparison of different radiometers will be discussed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/15237345','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/15237345"><span>[First clinical experience with extended planning and navigation in an interventional MRI unit].</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Moche, M; Schmitgen, A; Schneider, J P; Bublat, M; Schulz, T; Voerkel, C; Trantakis, C; Bennek, J; Kahn, T; Busse, H</p> <p>2004-07-01</p> <p>To present an advanced concept for patient-based navigation and to report on our first clinical experience with interventions in the cranium, of soft-tissue structures (breast, liver) and in the musculoskeletal system. A PC-based navigation system was integrated into an existing interventional MRI environment. Intraoperatively acquired 3D data were used for interventional planning. The information content of these reference data was increased by integration of additional image modalities (e. g., fMRI, CT) and by color display of areas with early contrast media enhancement. Within 18 months, the system was used in 123 patients undergoing interventions in different anatomic regions (brain: 64, paranasal sinus: 9, breast: 20, liver: 17, bone: 9, muscle: 4). The mean duration of 64 brain interventions was compared with that of 36 procedures using the scanner's standard navigation. In contrast with the continuous scanning mode of the MR system (0.25 fps), the higher quality as well as the real time display (4 fps) of the MR images reconstructed from the 3D reference data allowed adequate hand-eye coordination. With our system, patient movement and tissue shifts could be immediately detected intraoperatively, and, in contrast to the standard procedure, navigation safely resumed after updating the reference data. The navigation system was characterized by good stability, efficient system integration and easy usability. Despite additional working steps still to be optimized, the duration of the image-guided brain tumor resections was not significantly longer. The presented system combines the advantage of intraoperative MRI with established visualization, planning, and real time capabilities of neuronavigation and can be efficiently applied in a broad range of non-neurosurgical interventions.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22397788','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22397788"><span>Robotic-assisted laparoscopic partial nephrectomy: initial experience in Brazil and a review of the literature.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Passerotti, Carlo Camargo; Pessoa, Rodrigo; da Cruz, Jose Arnaldo Shiomi; Okano, Marcelo Takeo; Antunes, Alberto Azoubel; Nesrallah, Adriano Joao; Dall'oglio, Marcos Francisco; Andrade, Enrico; Srougi, Miguel</p> <p>2012-01-01</p> <p>Partial nephrectomy has become the standard of care for renal tumors less than 4 cm in diameter. Controversy still exists, however, regarding the best surgical approach, especially when minimally invasive techniques are taken into account. Robotic-assisted laparoscopic partial nephrectomy (RALPN) has emerged as a promising technique that helps surgeons achieve the standards of open partial nephrectomy care while offering a minimally invasive approach. The objective of the present study was to describe our initial experience with robotic-assisted laparoscopic partial nephrectomy and extensively review the pertinent literature. Between August 2009 and February 2010, eight consecutive selected patients with contrast enhancing renal masses observed by CT were submitted to RALPN in a private institution. In addition, we collected information on the patients ' demographics, preoperative tumor characteristics and detailed operative, postoperative and pathological data. In addition, a PubMed search was performed to provide an extensive review of the robotic-assisted laparoscopic partial nephrectomy literature. Seven patients had RALPN on the left or right sides with no intraoperative complications. One patient was electively converted to a robotic-assisted radical nephrectomy. The operative time ranged from 120 to 300 min, estimated blood loss (EBL) ranged from 75 to 400 mL and, in five cases, the warm ischemia time (WIT) ranged from 18 to 32 min. Two patients did not require any clamping. Overall, no transfusions were necessary, and there were no intraoperative complications or adverse postoperative clinical events. All margins were negative, and all patients were disease-free at the 6-month follow-up. Robotic-assisted laparoscopic partial nephrectomy is a feasible and safe approach to small renal cortical masses. Further prospective studies are needed to compare open partial nephrectomy with its minimally invasive counterparts.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24766365','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24766365"><span>Letter-case information and the identification of brand names.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Perea, Manuel; Jiménez, María; Talero, Fernanda; López-Cañada, Soraya</p> <p>2015-02-01</p> <p>A central tenet of most current models of visual-word recognition is that lexical units are activated on the basis of case-invariant abstract letter representations. Here, we examined this assumption by using a unique type of words: brand names. The rationale of the experiments is that brand names are archetypically printed either in lowercase (e.g., adidas) or uppercase (e.g., IKEA). This allows us to present the brand names in their standard or non-standard case configuration (e.g., adidas, IKEA vs. ADIDAS, ikea, respectively). We conducted two experiments with a brand-decision task ('is it a brand name?'): a single-presentation experiment and a masked priming experiment. Results in the single-presentation experiment revealed faster identification times of brand names in their standard case configuration than in their non-standard case configuration (i.e., adidas faster than ADIDAS; IKEA faster than ikea). In the masked priming experiment, we found faster identification times of brand names when they were preceded by an identity prime that matched its standard case configuration than when it did not (i.e., faster response times to adidas-adidas than to ADIDAS-adidas). Taken together, the present findings strongly suggest that letter-case information forms part of a brand name's graphemic information, thus posing some limits to current models of visual-word recognition. © 2014 The British Psychological Society.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_20");'>20</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li class="active"><span>22</span></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_22 --> <div id="page_23" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="441"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.gpo.gov/fdsys/pkg/CFR-2010-title25-vol2/pdf/CFR-2010-title25-vol2-sec304-4.pdf','CFR'); return false;" href="https://www.gpo.gov/fdsys/pkg/CFR-2010-title25-vol2/pdf/CFR-2010-title25-vol2-sec304-4.pdf"><span>25 CFR 304.4 - Standards and additional requirements.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.gpo.gov/fdsys/browse/collectionCfr.action?selectedYearFrom=2010&page.go=Go">Code of Federal Regulations, 2010 CFR</a></p> <p></p> <p>2010-04-01</p> <p>... 25 Indians 2 2010-04-01 2010-04-01 false Standards and additional requirements. 304.4 Section 304.4 Indians INDIAN ARTS AND CRAFTS BOARD, DEPARTMENT OF THE INTERIOR NAVAJO, PUEBLO, AND HOPI SILVER... in compliance with the standards set forth by the Indian Arts and Crafts Board, shall bear the...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://eric.ed.gov/?q=water+AND+meter&pg=3&id=EJ318899','ERIC'); return false;" href="https://eric.ed.gov/?q=water+AND+meter&pg=3&id=EJ318899"><span>Acid Rain Analysis by Standard Addition Titration.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.eric.ed.gov/ERICWebPortal/search/extended.jsp?_pageLabel=advanced">ERIC Educational Resources Information Center</a></p> <p>Ophardt, Charles E.</p> <p>1985-01-01</p> <p>The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3853011','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3853011"><span>Developing global health technology standards: what can other industries teach us?</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p></p> <p>2013-01-01</p> <p>Background There is a lack of effective and affordable technologies to address health needs in the developing world. One way to address problems of innovation and affordability is to design global health technologies to follow agreed-upon standards. This Debate article argues that we can better develop standards for global health technologies if we learn lessons from other industries. Discussion The article’s Background section begins by explaining why standards are needed in global health. For example, if global health technologies can be modularized into independent interfacing parts, these parts can then interact via well-defined standards in a “plug and play” fashion. This can avoid development of mutually incompatible solutions by different organizations, speed the pace of innovation, unlock health systems from single providers and approaches, and lower barriers to entry. The Background then gives a brief primer on standards and discusses incentives for health standards. The article’s Discussion section begins with brief relevant cases of standards development from other industries, including electricity, container shipping, CD standards, Universal Serial Bus (USB), and the Internet. It then explores lessons from these and other industries that suggest how to develop standards for global health technologies. The remainder of the Discussion considers intellectual property and regulatory issues and standards-based global health business models, and ends with a checklist of considerations for health standards development leaders. (The associated Additional file discusses observations from standards development for cell phones and semiconductors, as well as challenges in the standards development process itself.) Throughout the article, point-of-care diagnostics are used as an illustrative example. An initiative is already underway to explore standardized diagnostics platforms. Summary This Debate article aims to convince the reader that standards can benefit global health technologies if we learn lessons from other industries. The article draws from historical examples and the authors’ experiences to suggest principles, challenges, and opportunities in developing these standards. If implemented well, standardized platforms can lower barriers to entry, improve affordability, and create a vibrant ecosystem of innovative new global health technologies. PMID:24134866</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/pages/biblio/1409761-microprobe-analysis-pu-ga-standards','SCIGOV-DOEP'); return false;" href="https://www.osti.gov/pages/biblio/1409761-microprobe-analysis-pu-ga-standards"><span>Microprobe Analysis of Pu-Ga Standards</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/pages">DOE PAGES</a></p> <p>Wall, Angélique D.; Romero, Joseph P.; Schwartz, Daniel</p> <p>2017-08-04</p> <p>In order to obtain quantitative analysis using an Electron Scanning Microprobe it is essential to have a standard of known composition. Most elemental and multi-elemental standards can be easily obtained from places like Elemental Scientific or other standards organizations that are NIST (National Institute of Standards and Technology) traceable. It is, however, more challenging to find standards for plutonium. Past work performed in our group has typically involved using the plutonium sample to be analysed as its own standard as long as all other known components of the sample have standards to be compared to [1,2,3]. Finally, this method worksmore » well enough, but this experiment was performed in order to develop a more reliable standard for plutonium using five samples of known chemistry of a plutonium gallium mix that could then be used as the main plutonium and gallium standards for future experiments.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/biblio/1409761-microprobe-analysis-pu-ga-standards','SCIGOV-STC'); return false;" href="https://www.osti.gov/biblio/1409761-microprobe-analysis-pu-ga-standards"><span>Microprobe Analysis of Pu-Ga Standards</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Wall, Angélique D.; Romero, Joseph P.; Schwartz, Daniel</p> <p></p> <p>In order to obtain quantitative analysis using an Electron Scanning Microprobe it is essential to have a standard of known composition. Most elemental and multi-elemental standards can be easily obtained from places like Elemental Scientific or other standards organizations that are NIST (National Institute of Standards and Technology) traceable. It is, however, more challenging to find standards for plutonium. Past work performed in our group has typically involved using the plutonium sample to be analysed as its own standard as long as all other known components of the sample have standards to be compared to [1,2,3]. Finally, this method worksmore » well enough, but this experiment was performed in order to develop a more reliable standard for plutonium using five samples of known chemistry of a plutonium gallium mix that could then be used as the main plutonium and gallium standards for future experiments.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://rosap.ntl.bts.gov/view/dot/23312','DOTNTL'); return false;" href="https://rosap.ntl.bts.gov/view/dot/23312"><span>Assessing prior experience in the selection of air traffic control specialists.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntlsearch.bts.gov/tris/index.do">DOT National Transportation Integrated Search</a></p> <p></p> <p>2013-04-01</p> <p>Qualification standards published by the U.S. Office of Personnel Management (OPM) describe the minimum experience or education that individuals must have to qualify for specific positions within the federal government (OPM, 2009). These standards ar...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.epa.gov/environmental-economics/economic-impact-construction-industry-additional-demands-caused-new','PESTICIDES'); return false;" href="https://www.epa.gov/environmental-economics/economic-impact-construction-industry-additional-demands-caused-new"><span>The Economic Impact on the Construction Industry of Additional Demands Caused by New Environmental Protection Standards (1972)</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.epa.gov/pesticides/search.htm">EPA Pesticide Factsheets</a></p> <p></p> <p></p> <p>New facilities and additions to existing facilities will be required to meet the EPA's new (early 1970s) environmental quality standards. The report examines extent of these additional demands for construction and their economic impacts.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4126606','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4126606"><span>Ballistocardiogram Artifact Removal with a Reference Layer and Standard EEG Cap</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Luo, Qingfei; Huang, Xiaoshan; Glover, Gary H.</p> <p>2014-01-01</p> <p>Background In simultaneous EEG-fMRI, the EEG recordings are severely contaminated by ballistocardiogram (BCG) artifacts, which are caused by cardiac pulsations. To reconstruct and remove the BCG artifacts, one promising method is to measure the artifacts in the absence of EEG signal by placing a group of electrodes (BCG electrodes) on a conductive layer (reference layer) insulated from the scalp. However, current BCG reference layer (BRL) methods either use a customized EEG cap composed of electrode pairs, or need to construct the custom reference layer through additional model-building experiments for each EEG-fMRI experiment. These requirements have limited the versatility and efficiency of BRL. The aim of this study is to propose a more practical and efficient BRL method and compare its performance with the most popular BCG removal method, the optimal basis sets (OBS) algorithm. New Method By designing the reference layer as a permanent and reusable cap, the new BRL method is able to be used with a standard EEG cap, and no extra experiments and preparations are needed to use the BRL in an EEG-fMRI experiment. Results The BRL method effectively removed the BCG artifacts from both oscillatory and evoked potential scalp recordings and recovered the EEG signal. Comparison with Existing Method Compared to the OBS, this new BRL method improved the contrast-to-noise ratios of the alpha-wave, visual, and auditory evoked potential signals by 101%, 76%, and 75% respectively, employing 160 BCG electrodes. Using only 20 BCG electrodes, the BRL improved the EEG signal by 74%/26%/41% respectively. Conclusion The proposed method can substantially improve the EEG signal quality compared with traditional methods. PMID:24960423</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016PMB....61N.461B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016PMB....61N.461B"><span>Towards real-time thermometry using simultaneous multislice MRI</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Borman, P. T. S.; Bos, C.; de Boorder, T.; Raaymakers, B. W.; Moonen, C. T. W.; Crijns, S. P. M.</p> <p>2016-09-01</p> <p>MR-guided thermal therapies, such as high-intensity focused ultrasound (MRgHIFU) and laser-induced thermal therapy (MRgLITT) are increasingly being applied in oncology and neurology. MRI is used for guidance since it can measure temperature noninvasively based on the proton resonance frequency shift (PRFS). For therapy guidance using PRFS thermometry, high temporal resolution and large spatial coverage are desirable. We propose to use the parallel imaging technique simultaneous multislice (SMS) in combination with controlled aliasing (CAIPIRINHA) to accelerate the acquisition. We compare this with the sensitivity encoding (SENSE) acceleration technique. Two experiments were performed to validate that SMS can be used to increase the spatial coverage or the temporal resolution. The first was performed in agar gel using LITT heating and a gradient-echo sequence with echo-planar imaging (EPI), and the second was performed in bovine muscle using HIFU heating and a gradient-echo sequence without EPI. In both experiments temperature curves from an unaccelerated scan and from SMS, SENSE, and SENSE/SMS accelerated scans were compared. The precision was quantified by a standard deviation analysis of scans without heating. Both experiments showed a good agreement between the temperature curves obtained from the unaccelerated, and SMS accelerated scans, confirming that accuracy was maintained during SMS acceleration. The standard deviations of the temperature measurements obtained with SMS were significantly smaller than when SENSE was used, implying that SMS allows for higher acceleration. In the LITT and HIFU experiments SMS factors up to 4 and 3 were reached, respectively, with a loss of precision of less than a factor of 3. Based on these results we conclude that SMS acceleration of PRFS thermometry is a valuable addition to SENSE, because it allows for a higher temporal resolution or bigger spatial coverage, with a higher precision.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016MicST..28..297S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016MicST..28..297S"><span>ARADISH - Development of a Standardized Plant Growth Chamber for Experiments in Gravitational Biology Using Ground Based Facilities</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Schüler, Oliver; Krause, Lars; Görög, Mark; Hauslage, Jens; Kesseler, Leona; Böhmer, Maik; Hemmersbach, Ruth</p> <p>2016-06-01</p> <p>Plant development strongly relies on environmental conditions. Growth of plants in Biological Life Support Systems (BLSS), which are a necessity to allow human survival during long-term space exploration missions, poses a particular problem for plant growth, as in addition to the traditional environmental factors, microgravity (or reduced gravity such as on Moon or Mars) and limited gas exchange hamper plant growth. Studying the effects of reduced gravity on plants requires real or simulated microgravity experiments under highly standardized conditions, in order to avoid the influence of other environmental factors. Analysis of a large number of biological replicates, which is necessary for the detection of subtle phenotypical differences, can so far only be achieved in Ground Based Facilities (GBF). Besides different experimental conditions, the usage of a variety of different plant growth chambers was a major factor that led to a lack of reproducibility and comparability in previous studies. We have developed a flexible and customizable plant growth chamber, called ARAbidopsis DISH (ARADISH), which allows plant growth from seed to seedling, being realized in a hydroponic system or on Agar. By developing a special holder, the ARADISH can be used for experiments with Arabidopsis thaliana or a plant with a similar habitus on common GBF hardware, including 2D clinostats and Random Positioning Machines (RPM). The ARADISH growth chamber has a controlled illumination system of red and blue light emitting diodes (LED), which allows the user to apply defined light conditions. As a proof of concept we tested a prototype in a proteomic experiment in which plants were exposed to simulated microgravity or a 90° stimulus. We optimized the design and performed viability tests after several days of growth in the hardware that underline the utility of ARADISH in microgravity research.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/14996560','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/14996560"><span>Precision measurements of the RSA method using a phantom model of hip prosthesis.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Mäkinen, Tatu J; Koort, Jyri K; Mattila, Kimmo T; Aro, Hannu T</p> <p>2004-04-01</p> <p>Radiostereometric analysis (RSA) has become one of the recommended techniques for pre-market evaluation of new joint implant designs. In this study we evaluated the effect of repositioning of X-ray tubes and phantom model on the precision of the RSA method. In precision measurements, we utilized mean error of rigid body fitting (ME) values as an internal control for examinations. ME value characterizes relative motion among the markers within each rigid body and is conventionally used to detect loosening of a bone marker. Three experiments, each consisting of 10 double examinations, were performed. In the first experiment, the X-ray tubes and the phantom model were not repositioned between one double examination. In experiments two and three, the X-ray tubes were repositioned between one double examination. In addition, the position of the phantom model was changed in experiment three. Results showed that significant differences could be found in 2 of 12 comparisons when evaluating the translation and rotation of the prosthetic components. Repositioning procedures increased ME values mimicking deformation of rigid body segments. Thus, ME value seemed to be a more sensitive parameter than migration values in this study design. These results confirmed the importance of standardized radiographic technique and accurate patient positioning for RSA measurements. Standardization and calibration procedures should be performed with phantom models in order to avoid unnecessary radiation dose of the patients. The present model gives the means to establish and to follow the intra-laboratory precision of the RSA method. The model is easily applicable in any research unit and allows the comparison of the precision values in different laboratories of multi-center trials.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/24599192','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/24599192"><span>Ambient assisted living healthcare frameworks, platforms, standards, and quality attributes.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Memon, Mukhtiar; Wagner, Stefan Rahr; Pedersen, Christian Fischer; Beevi, Femina Hassan Aysha; Hansen, Finn Overgaard</p> <p>2014-03-04</p> <p>Ambient Assisted Living (AAL) is an emerging multi-disciplinary field aiming at exploiting information and communication technologies in personal healthcare and telehealth systems for countering the effects of growing elderly population. AAL systems are developed for personalized, adaptive, and anticipatory requirements, necessitating high quality-of-service to achieve interoperability, usability, security, and accuracy. The aim of this paper is to provide a comprehensive review of the AAL field with a focus on healthcare frameworks, platforms, standards, and quality attributes. To achieve this, we conducted a literature survey of state-of-the-art AAL frameworks, systems and platforms to identify the essential aspects of AAL systems and investigate the critical issues from the design, technology, quality-of-service, and user experience perspectives. In addition, we conducted an email-based survey for collecting usage data and current status of contemporary AAL systems. We found that most AAL systems are confined to a limited set of features ignoring many of the essential AAL system aspects. Standards and technologies are used in a limited and isolated manner, while quality attributes are often addressed insufficiently. In conclusion, we found that more inter-organizational collaboration, user-centered studies, increased standardization efforts, and a focus on open systems is needed to achieve more interoperable and synergetic AAL solutions.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29366464','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29366464"><span>The new ISO 6579-1: A real horizontal standard for detection of Salmonella, at last!</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Mooijman, Kirsten A</p> <p>2018-05-01</p> <p>Up to 2016, three international standard methods existed for the detection of Salmonella spp. in food, animal feed and samples from the primary production stage: ISO 6785:2001 for milk and milk products, ISO 6579:2002 for (other) food and animal feed and Annex D of ISO 6579:2007 for samples from the primary production stage. In 2009, an ISO/CEN working group started with the revision of ISO 6579:2002 with two main aims: combining the three aforementioned standards in one document and improving the information in ISO 6579:2002. Additionally it was decided to split ISO 6579 into three parts, where part 1 describes the detection, part 2 the enumeration by mini-MPN (published in 2012) and part 3 the serotyping of Salmonella (published in 2014). This paper describes the experiments and choices made for improving the part on detection of Salmonella (ISO 6579-1). The final voting stage on (draft) ISO 6579-1 was finished by the end of December 2016, with a positive outcome. Finally, a real horizontal standard became available for detection of Salmonella in food, animal feed, environmental samples in the area of food production and food handling and in samples from the primary production stage in 2017. Copyright © 2017 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/25047379','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/25047379"><span>Tools, harmonization and standardization procedures of the impact and outcome evaluation indices obtained during a kindergarten-based, family-involved intervention to prevent obesity in early childhood: the ToyBox-study.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Mouratidou, T; Miguel, M L; Androutsos, O; Manios, Y; De Bourdeaudhuij, I; Cardon, G; Kulaga, Z; Socha, P; Galcheva, S; Iotova, V; Payr, A; Koletzko, B; Moreno, L A</p> <p>2014-08-01</p> <p>The ToyBox-intervention is a kindergarten-based, family-involved intervention targeting multiple lifestyle behaviours in preschool children, their teachers and their families. This intervention was conducted in six European countries, namely Belgium, Bulgaria, Germany, Greece, Poland and Spain. The aim of this paper is to provide a descriptive overview of the harmonization and standardization procedures of the baseline and follow-up evaluation of the study (and substudies). Steps related to the study's operational, standardization and harmonization procedures as well as the impact and outcome evaluation assessment tools used are presented. Experiences from the project highlight the importance of safeguarding the measurement process to minimize data heterogeneity derived from potential measurement error and country-by-country differences. In addition, it was made clear that continuing quality control and support is an important component of such studies. For this reason, well-supported communication channels, such as regular email updates and teleconferences, and regular internal and external meetings to ensure smooth and accurate implementation were in place during the study. The ToyBox-intervention and its harmonized and standardized procedures can serve as a successful case study for future studies evaluating the efficacy of similar interventions. © 2014 World Obesity.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4003945','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4003945"><span>Ambient Assisted Living Healthcare Frameworks, Platforms, Standards, and Quality Attributes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Memon, Mukhtiar; Wagner, Stefan Rahr; Pedersen, Christian Fischer; Beevi, Femina Hassan Aysha; Hansen, Finn Overgaard</p> <p>2014-01-01</p> <p>Ambient Assisted Living (AAL) is an emerging multi-disciplinary field aiming at exploiting information and communication technologies in personal healthcare and telehealth systems for countering the effects of growing elderly population. AAL systems are developed for personalized, adaptive, and anticipatory requirements, necessitating high quality-of-service to achieve interoperability, usability, security, and accuracy. The aim of this paper is to provide a comprehensive review of the AAL field with a focus on healthcare frameworks, platforms, standards, and quality attributes. To achieve this, we conducted a literature survey of state-of-the-art AAL frameworks, systems and platforms to identify the essential aspects of AAL systems and investigate the critical issues from the design, technology, quality-of-service, and user experience perspectives. In addition, we conducted an email-based survey for collecting usage data and current status of contemporary AAL systems. We found that most AAL systems are confined to a limited set of features ignoring many of the essential AAL system aspects. Standards and technologies are used in a limited and isolated manner, while quality attributes are often addressed insufficiently. In conclusion, we found that more inter-organizational collaboration, user-centered studies, increased standardization efforts, and a focus on open systems is needed to achieve more interoperable and synergetic AAL solutions. PMID:24599192</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/6517','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/6517"><span>Experience implementing energy standards for commercial buildings and its lessons for the Philippines</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Busch, John; Deringer, Joseph</p> <p>1998-10-01</p> <p>Energy efficiency standards for buildings have been adopted in over forty countries. This policy mechanism is pursued by governments as a means of increasing energy efficiency in the buildings sector, which typically accounts for about a third of most nations' energy consumption and half of their electricity consumption. This study reports on experience with implementation of energy standards for commercial buildings in a number of countries and U.S. states. It is conducted from the perspective of providing useful input to the Government of the Philippines' (GOP) current effort at implementing their building energy standard. While the impetus for this workmore » is technical assistance to the Philippines, the intent is to shed light on the broader issues attending implementation of building energy standards that would be applicable there and elsewhere. The background on the GOP building energy standard is presented, followed by the objectives for the study, the approach used to collect and analyze information about other jurisdictions' implementation experience, results, and conclusions and recommendations.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1999JChEd..76.1421S','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1999JChEd..76.1421S"><span>Ascorbic Acid as a Standard for Iodometric Titrations. An Analytical Experiment for General Chemistry</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Silva, Cesar R.; Simoni, Jose A.; Collins, Carol H.; Volpe, Pedro L. O.</p> <p>1999-10-01</p> <p>Ascorbic acid is suggested as the weighable compound for the standardization of iodine solutions in an analytical experiment in general chemistry. The experiment involves an iodometric titration in which iodine reacts with ascorbic acid, oxidizing it to dehydroascorbic acid. The redox titration endpoint is determined by the first iodine excess that is complexed with starch, giving a deep blue-violet color. The results of the titration of iodine solution using ascorbic acid as a calibration standard were compared with the results acquired by the classic method using a standardized solution of sodium thiosulfate. The standardization of the iodine solution using ascorbic acid was accurate and precise, with the advantages of saving time and avoiding mistakes due to solution preparation. The colorless ascorbic acid solution gives a very clear and sharp titration end point with starch. It was shown by thermogravimetric analysis that ascorbic acid can be dried at 393 K for 2 h without decomposition. This experiment allows general chemistry students to perform an iodometric titration during a single laboratory period, determining with precision the content of vitamin C in pharmaceutical formulations.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/23895265','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/23895265"><span>A double standard when group members behave badly: transgression credit to ingroup leaders.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Abrams, Dominic; Randsley de Moura, Georgina; Travaglino, Giovanni A</p> <p>2013-11-01</p> <p>This research tested the hypothesis that people forgive serious transgressions by ingroup leaders but not by other group members or outgroup leaders. They apply a double standard in judgments of ingroup leaders. A series of studies (N = 623), using an array of different ingroups and outgroups, tested how group members judged ingroup or outgroup leaders and nonleaders who unexpectedly transgressed or did not transgress in important intergroup scenarios. Experiments 1, 2, and 4 focused on captains and players in either soccer or netball sports competitions. Across studies, transgressive captains of ingroup teams were evaluated more favorably than captains from outgroup teams and (Experiments 1, 2, and 4) more favorably than transgressive ingroup players. Experiment 3 demonstrated the double standard in a minimal group paradigm. Experiment 5 showed that the double standard is only applied if the leader is perceived as serving the group's interest. Across studies, the double standard is evident in evaluations toward, inclusion and punishment of, and rewards to the transgressive targets. Implications for sport, politics, and business and intergroup conflict are discussed. PsycINFO Database Record (c) 2013 APA, all rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21840333','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21840333"><span>Visual memories for perceived length are well preserved in older adults.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Norman, J Farley; Holmin, Jessica S; Bartholomew, Ashley N</p> <p>2011-09-15</p> <p>Three experiments compared younger (mean age was 23.7years) and older (mean age was 72.1years) observers' ability to visually discriminate line length using both explicit and implicit standard stimuli. In Experiment 1, the method of constant stimuli (with an explicit standard) was used to determine difference thresholds, whereas the method of single stimuli (where the knowledge of the standard length was only implicit and learned from previous test stimuli) was used in Experiments 2 and 3. The study evaluated whether increases in age affect older observers' ability to learn, retain, and utilize effective implicit visual standards. Overall, the observers' length difference thresholds were 5.85% of the standard when the method of constant stimuli was used and improved to 4.39% of the standard for the method of single stimuli (a decrease of 25%). Both age groups performed similarly in all conditions. The results demonstrate that older observers retain the ability to create, remember, and utilize effective implicit standards from a series of visual stimuli. Copyright © 2011 Elsevier Ltd. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/990840','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/990840"><span>Physics with a High Intensity Proton Source at Fermilab: Project X Golden Book</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Appel, Jeffrey; /Fermilab; Asner, David</p> <p>2008-02-03</p> <p>Within the next ten years the Standard Model will likely have to be modified to encompass a wide range of newly discovered phenomena, new elementary particles, new symmetries, and new dynamics. These phenomena will be revealed through experiment with high energy particle accelerators, mainly the LHC. This will represent a revolution in our understanding of nature, and will either bring us closer to an understanding of all phenomena, through existing ideas such as supersymmetry to superstrings, or will cause us to scramble to find new ideas and a new sense of direction. We are thus entering a dramatic and importantmore » time in the quest to understand the fundamental laws of nature and their role in shaping the universe. The energy scales now probed by the Tevatron, of order hundreds of GeV, will soon be subsumed by the LHC and extended up to a few TeV. We expect the unknown structure of the mysterious symmetry breaking of the Standard Model to be revealed. We will then learn the answer to a question that has a fundamental bearing upon our own existence: 'What is the origin of mass?' All modern theories of 'electroweak symmetry breaking' involve many new particles, mainly to provide a 'naturalness' rationale for the weak scale. Supersymmetry (SUSY) represents extra (fermionic) dimensions of space, leading to a doubling of the number of known elementary particles and ushering in many additional new particles and phenomena associated with the various symmetry breaking sectors. The possibility of additional bosonic dimensions of space would likewise usher in an even greater multitude of new states and new phenomena. Alternatively, any new spectroscopy may indicate new principles we have not yet anticipated, and we may see new strong forces and/or a dynamical origin of mass. The wealth of new particles, parameters, CP-phases, and other phenomena carries important implications for precision quark flavor physics experiments that are uniquely sensitive probes of new phenomena. We have already begun to see the enlargement of the Standard Model in the leptonic sector. Neutrino masses and mixing angles, which in the early 1990's were unknown, must now be incorporated into our full description of nature. In a minimal scenario of Majorana masses and mixings amongst the three known left-handed neutrinos, we see a strong hint of a new and very large mass scale, possibly associated with grand unification or the scale of quantum gravity, the Planck mass. We are not yet sure what the proper description of neutrino masses and mixing angles will be. Experiments may reveal additional unexpected particles coupled to the neutrino sector. New phenomena, such as leptonic CP-violation, will be major focal points of our expanding understanding of the lepton sector. There is much to be done with experiment to attack the issues that neutrinos now present. Already, developments in neutrino physics and the possibility of a novel source of CP-violation in the lepton sector have spawned hopes that the cosmic matter-antimatter asymmetry may be explained through leptogenesis. Neutrino physics, together with the search for new energy frontier physics, offers the possibility of experimental handles on the questions of dark matter and dark energy. Without the discovery of new particles in accelerator experiments, the telescope-based cosmological observations of the early universe would remain unexplained puzzles. The process of understanding the laws of physics in greater detail through accelerator-based high energy physics will potentially have incisive impact on our understanding of dark matter and dark energy. Precision flavor physics in both the quark and the lepton sectors offers a window on the sensitive entanglement of beyond-the-Standard-Model physics with rare processes, through quantum loop effects involving known or new states. Flavor physics offers sensitive indirect probes and may be the first place to reveal additional key components of the post-Standard Model physics. The main arenas for quark flavor physics include strange, charm and beauty, hence kaons, D-mesons, B-mesons and heavy baryons. A remarkable historical paradigm for the importance of flavor physics is the well known suppression of flavor-changing neutral currents. The analysis of the K{sub L}-K{sub S} mass difference by Gaillard and Lee, 35 years ago in the Fermilab Theory Group, led to the confirmation of the GIM mechanism and predicted the mass of the charm quark, m{sub c} {approx} 1.5 GeV, definitively and prior to its discovery. This, today, implies an astonishing constraint on SUSY models, e.g., that the down and strange squarks are mass degenerate to 1:10{sup 5}. This, in turn, has spawned a new working hypothesis called 'Minimal Flavor Violation' (MFV). But is MFV really a true principle operating in nature and, if so, where does it come from? Such questions can only be addressed in precision flavor physics experiments.« less</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li class="active"><span>23</span></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_23 --> <div id="page_24" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="461"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26264453','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26264453"><span>Developing educational competencies for dissemination and implementation research training programs: an exploratory analysis using card sorts.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Padek, Margaret; Colditz, Graham; Dobbins, Maureen; Koscielniak, Nikolas; Proctor, Enola K; Sales, Anne E; Brownson, Ross C</p> <p>2015-08-12</p> <p>With demand increasing for dissemination and implementation (D&I) training programs in the USA and other countries, more structured, competency-based, and tested curricula are needed to guide training programs. There are many benefits to the use of competencies in practice-based education such as the establishment of rigorous standards as well as providing an additional metrics for development and growth. As the first aim of a D&I training grant, an exploratory study was conducted to establish a new set of D&I competencies to guide training in D&I research. Based upon existing D&I training literature, the leadership team compiled an initial list of competencies. The research team then engaged 16 additional colleagues in the area of D&I science to provide suggestions to the initial list. The competency list was then additionally narrowed to 43 unique competencies following feedback elicited from these D&I researchers. Three hundred additional D&I researchers were then invited via email to complete a card sort in which the list of competencies were sorted into three categories of experience levels. Participants had previous first-hand experience with D&I or knowledge translation training programs in the past. Participants reported their self-identified D&I expertise level as well as the country in which their home institution is located. A mean score was calculated for each competency based on their experience level categorization. From these mean scores, beginner-, intermediate-, and advanced-level tertiles were created for the competencies. The card sort request achieved a 41 % response rate (n = 124). The list of 43 competencies was organized into four broad domains and sorted based on their experience level score. Eleven competencies were classified into the "Beginner" category, 27 into "Intermediate," and 5 into "Advanced." Education and training developers can use this competency list to formalize future trainings in D&I research, create more evidence-informed curricula, and enable overall capacity building and accompanying metrics in the field of D&I training and research.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19910010894','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19910010894"><span>National Educators' Workshop: Update 1988. Standard Experiments in Engineering Materials Science and Technology</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Gardner, James E. (Compiler); Jacobs, James A. (Compiler)</p> <p>1990-01-01</p> <p>Presented here is a collection of experiments presented and demonstrated at the National Educators' Workshop: Update 88, held May 10 to 12, 1988 at the National Institute of Standards and Technology (NIST), Gaithersberg, Maryland. The experiments related to the nature and properties of engineering materials and provided information to assist in teaching about materials in the education community.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2010AGUFM.B24C..03T','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2010AGUFM.B24C..03T"><span>TThe role of nitrogen availability in land-atmosphere interactions: a systematic evaluation of carbon-nitrogen coupling in a global land surface model using plot-level nitrogen fertilization experiments</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Thomas, R. Q.; Goodale, C. L.; Bonan, G. B.; Mahowald, N. M.; Ricciuto, D. M.; Thornton, P. E.</p> <p>2010-12-01</p> <p>Recent research from global land surface models emphasizes the important role of nitrogen cycling on global climate, via its control on the terrestrial carbon balance. Despite the implications of nitrogen cycling on global climate predictions, the research community has not performed a systematic evaluation of nitrogen cycling in global models. Here, we present such an evaluation for one global land model, CLM-CN. In the evaluation we simulated 45 plot-scale nitrogen-fertilization experiments distributed across 33 temperate and boreal forest sites. Model predictions were evaluated against field observations by comparing the vegetation and soil carbon responses to the additional nitrogen. Aggregated across all experiments, the model predicted a larger vegetation carbon response and a smaller soil carbon response than observed; the responses partially offset each other, leading to a slightly larger total ecosystem carbon response than observed. However, the model-observation agreement improved for vegetation carbon when the sites with observed negative carbon responses to nitrogen were excluded, which may be because the model lacks mechanisms whereby nitrogen additions increase tree mortality. Among experiments, younger forests and boreal forests’ vegetation carbon responses were less than predicted and mature forests (> 40 years old) were greater than predicted. Specific to the CLM-CN, this study used a systematic evaluation to identify key areas to focus model development, especially soil carbon- nitrogen interactions and boreal forest nitrogen cycling. Applicable to the modeling community, this study demonstrates a standardized protocol for comparing carbon-nitrogen interactions among global land models.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018EP%26S...70...79K','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018EP%26S...70...79K"><span>Archeointensity estimates of a tenth-century kiln: first application of the Tsunakawa-Shaw paleointensity method to archeological relics</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Kitahara, Yu; Yamamoto, Yuhji; Ohno, Masao; Kuwahara, Yoshihiro; Kameda, Shuichi; Hatakeyama, Tadahiro</p> <p>2018-05-01</p> <p>Paleomagnetic information reconstructed from archeological materials can be utilized to estimate the archeological age of excavated relics, in addition to revealing the geomagnetic secular variation and core dynamics. The direction and intensity of the Earth's magnetic field (archeodirection and archeointensity) can be ascertained using different methods, many of which have been proposed over the past decade. Among the new experimental techniques for archeointensity estimates is the Tsunakawa-Shaw method. This study demonstrates the validity of the Tsunakawa-Shaw method to reconstruct archeointensity from samples of baked clay from archeological relics. The validity of the approach was tested by comparison with the IZZI-Thellier method. The intensity values obtained coincided at the standard deviation (1 σ) level. A total of 8 specimens for the Tsunakawa-Shaw method and 16 specimens for the IZZI-Thellier method, from 8 baked clay blocks, collected from the surface of the kiln were used in these experiments. Among them, 8 specimens (for the Tsunakawa-Shaw method) and 3 specimens (for the IZZI-Thellier method) passed a set of strict selection criteria used in the final evaluation of validity. Additionally, we performed rock magnetic experiments, mineral analysis, and paleodirection measurement to evaluate the suitability of the baked clay samples for paleointensity experiments and hence confirmed that the sample properties were ideal for performing paleointensity experiments. It is notable that the newly estimated archaomagnetic intensity values are lower than those in previous studies that used other paleointensity methods for the tenth century in Japan. [Figure not available: see fulltext.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5980621','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=5980621"><span>Experience sampling methodology in mental health research: new insights and technical developments</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Myin‐Germeys, Inez; Kasanova, Zuzana; Vaessen, Thomas; Vachon, Hugo; Kirtley, Olivia; Viechtbauer, Wolfgang; Reininghaus, Ulrich</p> <p>2018-01-01</p> <p>In the mental health field, there is a growing awareness that the study of psychiatric symptoms in the context of everyday life, using experience sampling methodology (ESM), may provide a powerful and necessary addition to more conventional research approaches. ESM, a structured self‐report diary technique, allows the investigation of experiences within, and in interaction with, the real‐world context. This paper provides an overview of how zooming in on the micro‐level of experience and behaviour using ESM adds new insights and additional perspectives to standard approaches. More specifically, it discusses how ESM: a) contributes to a deeper understanding of psychopathological phenomena, b) allows to capture variability over time, c) aids in identifying internal and situational determinants of variability in symptomatology, and d) enables a thorough investigation of the interaction between the person and his/her environment and of real‐life social interactions. Next to improving assessment of psychopathology and its underlying mechanisms, ESM contributes to advancing and changing clinical practice by allowing a more fine‐grained evaluation of treatment effects as well as by providing the opportunity for extending treatment beyond the clinical setting into real life with the development of ecological momentary interventions. Furthermore, this paper provides an overview of the technical details of setting up an ESM study in terms of design, questionnaire development and statistical approaches. Overall, although a number of considerations and challenges remain, ESM offers one of the best opportunities for personalized medicine in psychiatry, from both a research and a clinical perspective. PMID:29856567</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29856567','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29856567"><span>Experience sampling methodology in mental health research: new insights and technical developments.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Myin-Germeys, Inez; Kasanova, Zuzana; Vaessen, Thomas; Vachon, Hugo; Kirtley, Olivia; Viechtbauer, Wolfgang; Reininghaus, Ulrich</p> <p>2018-06-01</p> <p>In the mental health field, there is a growing awareness that the study of psychiatric symptoms in the context of everyday life, using experience sampling methodology (ESM), may provide a powerful and necessary addition to more conventional research approaches. ESM, a structured self-report diary technique, allows the investigation of experiences within, and in interaction with, the real-world context. This paper provides an overview of how zooming in on the micro-level of experience and behaviour using ESM adds new insights and additional perspectives to standard approaches. More specifically, it discusses how ESM: a) contributes to a deeper understanding of psychopathological phenomena, b) allows to capture variability over time, c) aids in identifying internal and situational determinants of variability in symptomatology, and d) enables a thorough investigation of the interaction between the person and his/her environment and of real-life social interactions. Next to improving assessment of psychopathology and its underlying mechanisms, ESM contributes to advancing and changing clinical practice by allowing a more fine-grained evaluation of treatment effects as well as by providing the opportunity for extending treatment beyond the clinical setting into real life with the development of ecological momentary interventions. Furthermore, this paper provides an overview of the technical details of setting up an ESM study in terms of design, questionnaire development and statistical approaches. Overall, although a number of considerations and challenges remain, ESM offers one of the best opportunities for personalized medicine in psychiatry, from both a research and a clinical perspective. © 2018 World Psychiatric Association.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2011AcSpA..78.1196G','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2011AcSpA..78.1196G"><span>H-point standard additions method for simultaneous determination of sulfamethoxazole and trimethoprim in pharmaceutical formulations and biological fluids with simultaneous addition of two analytes</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Givianrad, M. H.; Saber-Tehrani, M.; Aberoomand-Azar, P.; Mohagheghian, M.</p> <p>2011-03-01</p> <p>The applicability of H-point standard additions method (HPSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim is verified by UV-vis spectrophotometry. The results show that the H-point standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. The results of applying the H-point standard additions method showed that the two drugs could be determined simultaneously with the concentration ratios of sulfamethoxazole to trimethoprim varying from 1:18 to 16:1 in the mixed samples. Also, the limits of detections were 0.58 and 0.37 μmol L -1 for sulfamethoxazole and trimethoprim, respectively. In addition the means of the calculated RSD (%) were 1.63 and 2.01 for SMX and TMP, respectively in synthetic mixtures. The proposed method has been successfully applied to the simultaneous determination of sulfamethoxazole and trimethoprim in some synthetic, pharmaceutical formulation and biological fluid samples.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/21256795','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/21256795"><span>H-point standard additions method for simultaneous determination of sulfamethoxazole and trimethoprim in pharmaceutical formulations and biological fluids with simultaneous addition of two analytes.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Givianrad, M H; Saber-Tehrani, M; Aberoomand-Azar, P; Mohagheghian, M</p> <p>2011-03-01</p> <p>The applicability of H-point standard additions method (HPSAM) to the resolving of overlapping spectra corresponding to the sulfamethoxazole and trimethoprim is verified by UV-vis spectrophotometry. The results show that the H-point standard additions method with simultaneous addition of both analytes is suitable for the simultaneous determination of sulfamethoxazole and trimethoprim in aqueous media. The results of applying the H-point standard additions method showed that the two drugs could be determined simultaneously with the concentration ratios of sulfamethoxazole to trimethoprim varying from 1:18 to 16:1 in the mixed samples. Also, the limits of detections were 0.58 and 0.37 μmol L(-1) for sulfamethoxazole and trimethoprim, respectively. In addition the means of the calculated RSD (%) were 1.63 and 2.01 for SMX and TMP, respectively in synthetic mixtures. The proposed method has been successfully applied to the simultaneous determination of sulfamethoxazole and trimethoprim in some synthetic, pharmaceutical formulation and biological fluid samples. Copyright © 2011 Elsevier B.V. All rights reserved.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/12014902','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/12014902"><span>Mobile zoned/exponential LAF screen: a new concept in ultra-clean air technology for additional operating room ventilation.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Friberg, B; Lindgren, M; Karlsson, C; Bergström, A; Friberg, S</p> <p>2002-04-01</p> <p>A mobile screen (0.5 x 0.4 m) producing ultra-clean exponential LAF (air-flow central zone 0.6 m/s and peripheral zone 0.4 m/s) was investigated as an addition to conventional turbulent/mixing operating room ventilation. The evaluation was performed during strictly standardized sham operations reflecting conditions during major surgery. The study consisted of a pilot experiment designed to give high counts of sedimenting aerobic colony forming units (cfu). In a second main study, recording dust particles, air-borne and sedimenting aerobic cfu, the screen was associated with optimal operating room clothing. In the pilot experiment the use of the screen resulted in a substantial reduction of sedimenting bacteria from 3835-4940 to 0-390 cfu/m(2)/h. In the main study, the use of the additional LAF reduced the surface contamination from 416-329 to 7-78 cfu/m(2)/h up to 1.6 m from the screen (P=0.001-0.0001). Measured in the wound area the screen reduced the air counts of bacteria from 9-14 to 0.2-0.4 cfu/m(3) (P=0.008-0.0001) and a marked reduction of air-borne dust particles was recorded (P=0.007-0.009). In conclusion, the additional mobile LAF screen reduced the counts of aerobic air-borne and sedimenting bacteria-carrying particles as well as dust particles to the levels gained with complete ultra-clean LAF room ventilation. Thus, the screen might prove a valuable addition to operating room ventilation as well as in other areas where asepsis is essential. Copyright 2002 The Hospital Infection Society.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1394445','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1394445"><span></span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Wilcox, Kevin R.; Shi, Zheng; Gherardi, Laureano A.</p> <p></p> <p>Climatic changes are altering Earth's hydrological cycle, resulting in altered precipitation amounts, increased interannual variability of precipitation, and more frequent extreme precipitation events. These trends will likely continue into the future, having substantial impacts on net primary productivity (NPP) and associated ecosystem services such as food production and carbon sequestration. Frequently, experimental manipulations of precipitation have linked altered precipitation regimes to changes in NPP. Yet, findings have been diverse and substantial uncertainty still surrounds generalities describing patterns of ecosystem sensitivity to altered precipitation. Additionally, we do not know whether previously observed correlations between NPP and precipitation remain accurate when precipitationmore » changes become extreme. We synthesized results from 83 case studies of experimental precipitation manipulations in grasslands worldwide. Here, we used meta-analytical techniques to search for generalities and asymmetries of aboveground NPP (ANPP) and belowground NPP (BNPP) responses to both the direction and magnitude of precipitation change. Sensitivity (i.e., productivity response standardized by the amount of precipitation change) of BNPP was similar under precipitation additions and reductions, but ANPP was more sensitive to precipitation additions than reductions; this was especially evident in drier ecosystems. Additionally, overall relationships between the magnitude of productivity responses and the magnitude of precipitation change were saturating in form. The saturating form of this relationship was likely driven by ANPP responses to very extreme precipitation increases, although there were limited studies imposing extreme precipitation change, and there was considerable variation among experiments. Finally, this highlights the importance of incorporating gradients of manipulations, ranging from extreme drought to extreme precipitation increases into future climate change experiments. Additionally, policy and land management decisions related to global change scenarios should consider how ANPP and BNPP responses may differ, and that ecosystem responses to extreme events might not be predicted from relationships found under moderate environmental changes.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2015PhDT.........2B','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2015PhDT.........2B"><span>The search for the pair production of second-generation scalar leptoquarks and measurements of the differential cross sections of the W boson produced in association with jets with the CMS detector at the LHC</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Baumgartel, Darin C.</p> <p></p> <p>Since the formulation of the Standard Model of particle physics, numerous experiments have sought to observe the signatures of the subatomic particles by examining the outcomes of charged particle collisions. Over time, advances in detector technology and scientific computing have allowed for unprecedented precision measurements of Standard Model phenomena and particle properties. Although the Standard Model has displayed remarkable predictive power, extensions to the Standard Model have been formulated to account for unexplained phenomena, and these extensions often infer the existence of additional subatomic particles. Consequently, experiments at particle colliders often endeavor to search for signatures of physics beyond the Standard Model. These searches and measurements are often complementary pursuits, as searches are often limited by the precision of estimations of the Standard Model backgrounds. At the forefront of present-day collider experiments is the Large Hadron Collider at CERN, which delivers proton-proton collisions with unprecedented energy and luminosity. Collisions are recorded with detectors located at interaction points along the ring of the Large Hadron Collider. The CMS detector is one of two general-purpose detectors at the Large Hadron Collider, and the high-precision detection of particles from collision events in the CMS detector make the CMS detector a powerful tool for both Standard-Model measurements and searches for new physics. The Standard Model is characterized by three generation of quarks and leptons. This correspondence between the generations of quarks and leptons is necessary to allow for the renormalizability of the Standard Model, but it is not an inherent property of the Standard Model. Motivated by this compelling symmetry, many theories and models propose the existence of leptoquark bosons which mediate transitions between quarks and leptons. Experimental constraints indicate that leptoquarks would couple to a single generation, and this thesis describes searches for leptoquarks produced in pairs and decaying to final states containing either two muons and two jets, or one muon, one muon-neutrino, and two jets. Searches are conducted with collision data at center-of-mass energies of both 7 TeV and 8 TeV. No compelling evidence for the existence of leptoquarks is found, and upper limits on the leptoquark mass and cross section are placed at the 95% confidence level. These limits are the most stringent to date, and are several times larger than limits placed previously at hadron collider experiments. While the pair production of massive leptoquark bosons yields final states which have strong kinematic differences from the Standard Model processes, the ability to exploit these differences is limited by the ability to accurately model the backgrounds. The most notable of these backgrounds is the production of a W boson in association with one or more jets. Since the W+jets process has a very large cross section and a final state containing missing energy, its contribution to the total Standard Model background is both nominally large and more difficult to discriminate against than backgrounds with only visible final state objects. Furthermore, estimates of this background are not easily improved by comparisons with data in control regions, and simulations of the background are often limited to leading-order predictions. To improve the understanding and modeling of this background for future endeavors, this thesis also presents measurements of the W+jets process differentially as a function of several variables, including the jet multiplicity, the individual jet transverse momenta and pseudorapidities, the angular separation between the jets and the muon, and the scalar sum of the transverse momenta of all jets. The agreement of these measurements with respect to predictions from event leading-order generators and next-to-leading-order calculations is assessed.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/17714339','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/17714339"><span>'Good luck to them if they can get it': exploring working class men's understandings and experiences of income inequality and material standards.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Dolan, Alan</p> <p>2007-07-01</p> <p>This paper seeks to contribute to the recent debate within the field of inequalities in health that has focused on the relationship between income distribution and health. This has contested the extent to which the main effects of income on health are not directly related to material standards but operate through psychosocial mechanisms, linked to how people experience and perceive their relative position. However, whilst this has focused attention on the qualitative dimensions of income inequality as a potential determinant of health inequality, very little empirical work has directly examined lay perspectives. In this study I attempted to address this gap by exploring how two groups of working class men living in contrasting socio-economic areas understood and experienced differences in income and material circumstances and how these were perceived to impact on their health. This study shows that the anger and resentment felt by these men had their roots largely in the perceptions of others and the way others treated them, rather than in income differentials per se. There was little evidence of feelings of shame or inferiority. For men at the bottom of the social ladder, financial hardship was additionally perceived as having the greatest impact on their health and well-being.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4657936','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4657936"><span>“They See Us As Machines:” The Experience of Recent Immigrant Women in the Low Wage Informal Labor Sector</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p></p> <p>2015-01-01</p> <p>This study explores the organization of work and occupational health risk as elicited from recently immigrated women (n = 8) who have been in the US for less than three years and employed in informal work sectors such as cleaning and factory work in the greater Boston area in Massachusetts. Additional interviews (n = 8) with Community Key Informants with knowledge of this sector and representatives of temporary employment agencies in the area provides further context to the interviews conducted with recent immigrant women. These results were also compared with our immigrant occupational health survey, a large project that spawned this study. Responses from the study participants suggest health outcomes consistent with being a day-laborer scholarship, new immigrant women are especially at higher risk within these low wage informal work sectors. A difference in health experiences based on ethnicity and occupation was also observed. Low skilled temporary jobs are fashioned around meeting the job performance expectations of the employer; the worker’s needs are hardly addressed, resulting in low work standards, little worker protection and poor health outcomes. The rising prevalence of non-standard employment or informal labor sector requires that policies or labor market legislation be revised to meet the needs presented by these marginalized workers. PMID:26600083</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26600083','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26600083"><span>"They See Us As Machines:" The Experience of Recent Immigrant Women in the Low Wage Informal Labor Sector.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Panikkar, Bindu; Brugge, Doug; Gute, David M; Hyatt, Raymond R</p> <p>2015-01-01</p> <p>This study explores the organization of work and occupational health risk as elicited from recently immigrated women (n = 8) who have been in the US for less than three years and employed in informal work sectors such as cleaning and factory work in the greater Boston area in Massachusetts. Additional interviews (n = 8) with Community Key Informants with knowledge of this sector and representatives of temporary employment agencies in the area provides further context to the interviews conducted with recent immigrant women. These results were also compared with our immigrant occupational health survey, a large project that spawned this study. Responses from the study participants suggest health outcomes consistent with being a day-laborer scholarship, new immigrant women are especially at higher risk within these low wage informal work sectors. A difference in health experiences based on ethnicity and occupation was also observed. Low skilled temporary jobs are fashioned around meeting the job performance expectations of the employer; the worker's needs are hardly addressed, resulting in low work standards, little worker protection and poor health outcomes. The rising prevalence of non-standard employment or informal labor sector requires that policies or labor market legislation be revised to meet the needs presented by these marginalized workers.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20140001404','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20140001404"><span>Modeling the Skills and Practices of Scientists through an “All-Inclusive” Comparative Planetology Student Research Investigation</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Graff, Paige; Bandfield, J.; Stefanov, W.; Vanderbloemen, L.; Willis, K.; Runco, S.</p> <p>2013-01-01</p> <p>To effectively prepare the nation's future Science, Technology, Engineering, and Mathematics (STEM) workforce, students in today's classrooms need opportunities to engage in authentic experiences that model skills and practices used by STEM professionals. Relevant, real-world authentic research experiences allow students to behave as scientists as they model the process of science. This enables students to get a true sense of STEM-related professions and also allows them to develop the requisite knowledge, skills, curiosity, and creativity necessary for success in STEM careers. Providing professional development and opportunities to help teachers infuse research in the classroom is one of the primary goals of the Expedition Earth and Beyond (EEAB) program. EEAB, facilitated by the Astromaterials Research and Exploration Science (ARES) Directorate at the NASA Johnson Space Center, is an Earth and planetary science education program designed to inspire, engage, and educate teachers and students in grades 5-12 by getting them actively involved with exploration, discovery, and the process of science. The program combines the expertise of scientists and educators to ensure the professional development provided to classroom teachers is scientifically valid and also recognizes classroom constraints. For many teachers, facilitating research in the classroom can be challenging. In addition to addressing required academic standards and dealing with time constraints, challenges include structuring a research investigation the entire class can successfully complete. To build educator confidence, foster positive classroom research experiences, and enable teachers to help students model the skills and practices of scientists, EEAB has created an "allinclusive" comparative planetology research investigation activity. This activity addresses academic standards while recognizing students (and teachers) potentially lack experience with scientific practices involved in conducting research. Designed as an entry level research engagement investigation, the activity introduces, illustrates, and teaches the skills involved in each step of the research process. Students use astronaut photos, provided through the ARES Crew Earth Observations (CEO) payload on the International Space Station (ISS) as well as remote sensing imagery of other planetary worlds. By including all the necessary tools to complete the investigation, students can focus on gaining experience in the process of science. Additionally, students are able to extend their experience of modeling the skills and practices of scientists through the opportunity to request new data of Earth from the ISS. Professional development offered through in-person and webinar trainings, along with the resources provided, enable educators to gain first-hand experience implementing a structured research investigation in the classroom. Through data and feedback collected from teachers, this type of "all-inclusive" investigation activity aims to become a model that can be utilized for other research topics and STEM disciplines.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2013AGUFMED14B..06G','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2013AGUFMED14B..06G"><span>Modeling the Skills and Practices of Scientists through an 'All-Inclusive' Comparative Planetology Student Research Investigation</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Graff, P. V.; Bandfield, J. L.; Stefanov, W. L.; Vanderbloemen, L.; Willis, K. J.; Runco, S.</p> <p>2013-12-01</p> <p>To effectively prepare the nation's future Science, Technology, Engineering, and Mathematics (STEM) workforce, students in today's classrooms need opportunities to engage in authentic experiences that model skills and practices used by STEM professionals. Relevant, real-world authentic research experiences allow students to behave as scientists as they model the process of science. This enables students to get a true sense of STEM-related professions and also allows them to develop the requisite knowledge, skills, curiosity, and creativity necessary for success in STEM careers. Providing professional development and opportunities to help teachers infuse research in the classroom is one of the primary goals of the Expedition Earth and Beyond (EEAB) program. EEAB, facilitated by the Astromaterials Research and Exploration Science (ARES) Directorate at the NASA Johnson Space Center, is an Earth and planetary science education program designed to inspire, engage, and educate teachers and students in grades 5-12 by getting them actively involved with exploration, discovery, and the process of science. The program combines the expertise of scientists and educators to ensure the professional development provided to classroom teachers is scientifically valid and also recognizes classroom constraints. For many teachers, facilitating research in the classroom can be challenging. In addition to addressing required academic standards and dealing with time constraints, challenges include structuring a research investigation the entire class can successfully complete. To build educator confidence, foster positive classroom research experiences, and enable teachers to help students model the skills and practices of scientists, EEAB has created an 'all-inclusive' comparative planetology research investigation activity. This activity addresses academic standards while recognizing students (and teachers) potentially lack experience with scientific practices involved in conducting research. Designed as an entry level research engagement investigation, the activity introduces, illustrates, and teaches the skills involved in each step of the research process. Students use astronaut photos, provided through the ARES Crew Earth Observations (CEO) payload on the International Space Station (ISS) as well as remote sensing imagery of other planetary worlds. By including all the necessary tools to complete the investigation, students can focus on gaining experience in the process of science. Additionally, students are able to extend their experience of modeling the skills and practices of scientists through the opportunity to request new data of Earth from the ISS. Professional development offered through in-person and webinar trainings, along with the resources provided, enable educators to gain first-hand experience implementing a structured research investigation in the classroom. Through data and feedback collected from teachers, this type of 'all-inclusive' investigation activity aims to become a model that can be utilized for other research topics and STEM disciplines.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19760011137','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19760011137"><span>A study of low cost approaches to scientific experiment implementation for shuttle launched and serviced automated spacecraft</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p></p> <p>1975-01-01</p> <p>Cost reductions that can be obtained in experiment instrumentation by the use of standardized electronics and by the relaxation of instrument reliability requirements are studied. The feasibility of using standardized equipment for experiment instrumentation is assessed and a system design approach that most effectively incorporates standardized equipment is developed. The level and form of modularization that is appropriate for the standardized equipment is determined. Mission assurance aspects of instrument development are examined to determine the cost reductions that might be derived from the relaxation of reliability requirements and to formulate a systematic approach to the optimization of mission assurance cost reductions. The results of the analyses are applied to a representative model HEAO payload in order to provide a concrete example of the cost reductions that can be achieved by a standardized approach to the instrument electronics.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.osti.gov/servlets/purl/1327281','SCIGOV-STC'); return false;" href="https://www.osti.gov/servlets/purl/1327281"><span>The New Muon g₋2 experiment at Fermilab</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.osti.gov/search">DOE Office of Scientific and Technical Information (OSTI.GOV)</a></p> <p>Venanzoni, Graziano</p> <p>2016-06-02</p> <p>There is a long standing discrepancy between the Standard Model prediction for the muon g-2 and the value measured by the Brookhaven E821 Experiment. At present the discrepancy stands at about three standard deviations, with a comparable accuracy between experiment and theory. Two new proposals -- at Fermilab and J-PARC -- plan to improve the experimental uncertainty by a factor of 4, and it is expected that there will be a significant reduction in the uncertainty of the Standard Model prediction. I will review the status of the planned experiment at Fermilab, E989, which will analyse 21 times more muonsmore » than the BNL experiment and discuss how the systematic uncertainty will be reduced by a factor of 3 such that a precision of 0.14 ppm can be achieved.« less</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/22330784','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/22330784"><span>Inclusion of policies on ethical standards in animal experiments in biomedical science journals.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Rands, Sean A</p> <p>2011-11-01</p> <p>Most published biomedical research involving animal models is evaluated carefully to ensure that appropriate ethical standards are met. In the current study, 500 journals randomly selected from MedLine were assessed for whether they presented animal research. Of the 138 journals that did, the instructions to authors of 85 (61.6%) included a requirement for author assurance of adherence to ethical standards during experiments involving animals. In comparison to a wider range of biologic journals, biomedical science journals were more likely to have some sort of ethical policy concerning the reporting and presentation of animal experiments.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2018PhRvD..97i5039M','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2018PhRvD..97i5039M"><span>Testing Lorentz and C P T invariance with ultracold neutrons</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Martín-Ruiz, A.; Escobar, C. A.</p> <p>2018-05-01</p> <p>In this paper we investigate, within the standard model extension framework, the influence of Lorentz- and C P T -violating terms on gravitational quantum states of ultracold neutrons. Using a semiclassical wave packet, we derive the effective nonrelativistic Hamiltonian which describes the neutrons vertical motion by averaging the contributions from the perpendicular coordinates to the free falling axis. We compute the physical implications of the Lorentz- and C P T -violating terms on the spectra. The comparison of our results with those obtained in the GRANIT experiment leads to an upper bound for the symmetries-violation cμν n coefficients. We find that ultracold neutrons are sensitive to the ain and ein coefficients, which thus far are unbounded by experiments in the neutron sector. We propose two additional problems involving ultracold neutrons which could be relevant for improving our current bounds; namely, gravity-resonance spectroscopy and neutron whispering gallery wave.</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li class="active"><span>24</span></li> <li><a href="#" onclick='return showDiv("page_25");'>25</a></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_24 --> <div id="page_25" class="hiddenDiv"> <div class="row"> <div class="col-sm-12"> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div> </div> <div class="row"> <div class="col-sm-12"> <ol class="result-class" start="481"> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26248301','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26248301"><span>Inter-laboratory comparison of the in vivo comet assay including three image analysis systems.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Plappert-Helbig, Ulla; Guérard, Melanie</p> <p>2015-12-01</p> <p>To compare the extent of potential inter-laboratory variability and the influence of different comet image analysis systems, in vivo comet experiments were conducted using the genotoxicants ethyl methanesulfonate and methyl methanesulfonate. Tissue samples from the same animals were processed and analyzed-including independent slide evaluation by image analysis-in two laboratories with extensive experience in performing the comet assay. The analysis revealed low inter-laboratory experimental variability. Neither the use of different image analysis systems, nor the staining procedure of DNA (propidium iodide vs. SYBR® Gold), considerably impacted the results or sensitivity of the assay. In addition, relatively high stability of the staining intensity of propidium iodide-stained slides was found in slides that were refrigerated for over 3 months. In conclusion, following a thoroughly defined protocol and standardized routine procedures ensures that the comet assay is robust and generates comparable results between different laboratories. © 2015 Wiley Periodicals, Inc.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4300582','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=4300582"><span>The full metallic double-pigtail ureteral stent: Review of the clinical outcome and current status</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Kallidonis, Panagiotis S.; Georgiopoulos, Ioannis S.; Kyriazis, Iason D.; Kontogiannis, Stavros; Al-Aown, Abdulrahman M.; Liatsikos, Evangelos N.</p> <p>2015-01-01</p> <p>The full metallic double-J ureteral stent (MS) was introduced as a method for providing long-term drainage in malignant ureteral obstruction. Experimental evaluation of the MS revealed that its mechanical features allow efficient drainage in difficult cases, which could not be managed by the insertion of a standard polymeric double-J stent. Clinical experience with the MS showed controversial results. Careful patient selection results in efficient long-term management of malignant ureteral obstruction. The use of the MS should also be considered in selected benign cases. Major complications are uncommon and the minor complications should not hinder its use. Experience in pediatric patients is limited and warrants additional study. The cost-effectiveness of the MS seems to be appropriate for long-term treatment. Further investigation with comparative clinical trials would document the outcome more extensively and establish the indications as well as the selection criteria for the MS. PMID:25624569</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/20552381','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/20552381"><span>Artificial intelligence systems based on texture descriptors for vaccine development.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Nanni, Loris; Brahnam, Sheryl; Lumini, Alessandra</p> <p>2011-02-01</p> <p>The aim of this work is to analyze and compare several feature extraction methods for peptide classification that are based on the calculation of texture descriptors starting from a matrix representation of the peptide. This texture-based representation of the peptide is then used to train a support vector machine classifier. In our experiments, the best results are obtained using local binary patterns variants and the discrete cosine transform with selected coefficients. These results are better than those previously reported that employed texture descriptors for peptide representation. In addition, we perform experiments that combine standard approaches based on amino acid sequence. The experimental section reports several tests performed on a vaccine dataset for the prediction of peptides that bind human leukocyte antigens and on a human immunodeficiency virus (HIV-1). Experimental results confirm the usefulness of our novel descriptors. The matlab implementation of our approaches is available at http://bias.csr.unibo.it/nanni/TexturePeptide.zip.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017AGUFMNG31A0148M','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017AGUFMNG31A0148M"><span>Localization of a variational particle smoother</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Morzfeld, M.; Hodyss, D.; Poterjoy, J.</p> <p>2017-12-01</p> <p>Given the success of 4D-variational methods (4D-Var) in numerical weather prediction,and recent efforts to merge ensemble Kalman filters with 4D-Var,we consider a method to merge particle methods and 4D-Var.This leads us to revisit variational particle smoothers (varPS).We study the collapse of varPS in high-dimensional problemsand show how it can be prevented by weight-localization.We test varPS on the Lorenz'96 model of dimensionsn=40, n=400, and n=2000.In our numerical experiments, weight localization prevents the collapse of the varPS,and we note that the varPS yields results comparable to ensemble formulations of 4D-variational methods,while it outperforms EnKF with tuned localization and inflation,and the localized standard particle filter.Additional numerical experiments suggest that using localized weights in varPS may not yield significant advantages over unweighted or linearizedsolutions in near-Gaussian problems.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2016SPIE.9979E..0QV','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2016SPIE.9979E..0QV"><span>The FESTER field trial</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>van Eijk, Alexander M. J.; Gunter, Willie H.; February, Faith J.; Maritz, Benita; Vrahimis, George; Koago, Mokete S.; Wainman, Carl; Eisele, Christian; Seiffer, Dirk; Sucher, Erik; Stein, Karin; van Iersel, Miranda; Cohen, Leo H.; Van Binsbergen, Sven A.; Heemskerk, H. J. M. (Eric); Sternberg, A.; Schulte, H.; van Rheenen, Arthur D.; Brenthagen, Erik; Thomassen, Jan B.; Griffith, D.</p> <p>2016-09-01</p> <p>An overview is given of the First European - South African Transmission ExpeRiment (FESTER), which took place in South Africa, over the False Bay area, centered around Simon's Town. The experiment lasted from April 2015 through February 2016 and involved continuous observations as well as periodic observations that took place during four Intensive Observation Periods (IOPs) of 2 weeks each, which were spread over the year. The continuous observations aimed at a characterization of the electro-optical propagation environment, and included standard meteorology, aerosol, refraction and turbulence measurements. The periodic observations aimed at assessing the performance of electro-optical sensors in VIS / SWIR / MWIR and LWIR wavebands by following a boat sailing outbound and inbound tracks. In addition, dynamic aspects of electro-optical signatures, i.e., the changes induced by variations in the environment and/or target orientation, were studied. The present paper provides an overview of the trial, and presents a few first results.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2015JSEdT..24..476N','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2015JSEdT..24..476N"><span>Integration of Video-Based Demonstrations to Prepare Students for the Organic Chemistry Laboratory</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Nadelson, Louis S.; Scaggs, Jonathan; Sheffield, Colin; McDougal, Owen M.</p> <p>2015-08-01</p> <p>Consistent, high-quality introductions to organic chemistry laboratory techniques effectively and efficiently support student learning in the organic chemistry laboratory. In this work, we developed and deployed a series of instructional videos to communicate core laboratory techniques and concepts. Using a quasi-experimental design, we tested the videos in five traditional laboratory experiments by integrating them with the standard pre-laboratory student preparation presentations and instructor demonstrations. We assessed the influence of the videos on student laboratory knowledge and performance, using sections of students who did not view the videos as the control. Our analysis of pre-quizzes revealed the control group had equivalent scores to the treatment group, while the post-quiz results show consistently greater learning gains for the treatment group. Additionally, the students who watched the videos as part of their pre-laboratory instruction completed their experiments in less time.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/26281435','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/26281435"><span>Developing occupational therapy students' practice habits via qualitative inquiry education.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Marterella, Abbey L; Aldrich, Rebecca M</p> <p>2015-04-01</p> <p>Accreditation standards and practice competencies underscore the importance of research for occupational therapy practice, but they do not guide how occupational therapy education addresses research. Despite the prominence of qualitative research in the health professions, there exists a need to articulate how and why qualitative inquiry is taught in occupational therapy education. We discuss how qualitative inquiry education can develop habits of reflection and reflexivity, criticality, and active engagement in preparation for occupational therapy practice. We hold that our students' professional abilities to practice in a well-reasoned, ethical, and responsive manner are enhanced by experiences with qualitative inquiry and suggest that there is potential in linking qualitative inquiry experiences to professional habit formation in occupational therapy education. In addition to teaching research for its own sake, we suggest that educators can adopt a broader view of how qualitative inquiry functions within occupational therapy education.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/11816458','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/11816458"><span>A word processor optimized for preparing journal articles and student papers.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Wolach, A H; McHale, M A</p> <p>2001-11-01</p> <p>A new Windows-based word processor for preparing journal articles and student papers is described. In addition to standard features found in word processors, the present word processor provides specific help in preparing manuscripts. Clicking on "Reference Help (APA Form)" in the "File" menu provides a detailed help system for entering the references in a journal article. Clicking on "Examples and Explanations of APA Form" provides a help system with examples of the various sections of a review article, journal article that has one experiment, or journal article that has two or more experiments. The word processor can automatically place the manuscript page header and page number at the top of each page using the form required by APA and Psychonomic Society journals. The "APA Form" submenu of the "Help" menu provides detailed information about how the word processor is optimized for preparing articles and papers.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/1995ctm..work...39Z','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/1995ctm..work...39Z"><span>A summary of computational experience at GE Aircraft Engines for complex turbulent flows in gas turbines</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Zerkle, Ronald D.; Prakash, Chander</p> <p>1995-03-01</p> <p>This viewgraph presentation summarizes some CFD experience at GE Aircraft Engines for flows in the primary gaspath of a gas turbine engine and in turbine blade cooling passages. It is concluded that application of the standard k-epsilon turbulence model with wall functions is not adequate for accurate CFD simulation of aerodynamic performance and heat transfer in the primary gas path of a gas turbine engine. New models are required in the near-wall region which include more physics than wall functions. The two-layer modeling approach appears attractive because of its computational complexity. In addition, improved CFD simulation of film cooling and turbine blade internal cooling passages will require anisotropic turbulence models. New turbulence models must be practical in order to have a significant impact on the engine design process. A coordinated turbulence modeling effort between NASA centers would be beneficial to the gas turbine industry.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.ncbi.nlm.nih.gov/pubmed/29761427','PUBMED'); return false;" href="https://www.ncbi.nlm.nih.gov/pubmed/29761427"><span>The Importance of Experimental Design, Quality Assurance, and Control in Plant Metabolomics Experiments.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="https://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pubmed">PubMed</a></p> <p>Martins, Marina C M; Caldana, Camila; Wolf, Lucia Daniela; de Abreu, Luis Guilherme Furlan</p> <p>2018-01-01</p> <p>The output of metabolomics relies to a great extent upon the methods and instrumentation to identify, quantify, and access spatial information on as many metabolites as possible. However, the most modern machines and sophisticated tools for data analysis cannot compensate for inappropriate harvesting and/or sample preparation procedures that modify metabolic composition and can lead to erroneous interpretation of results. In addition, plant metabolism has a remarkable degree of complexity, and the number of identified compounds easily surpasses the number of samples in metabolomics analyses, increasing false discovery risk. These aspects pose a large challenge when carrying out plant metabolomics experiments. In this chapter, we address the importance of a proper experimental design taking into consideration preventable complications and unavoidable factors to achieve success in metabolomics analysis. We also focus on quality control and standardized procedures during the metabolomics workflow.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20130010714','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20130010714"><span>The Effects of Development Team Skill on Software Product Quality</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Beaver, Justin M.; Schiavone, Guy A.</p> <p>2006-01-01</p> <p>This paper provides an analysis of the effect of the skill/experience of the software development team on the quality of the final software product. A method for the assessment of software development team skill and experience is proposed, and was derived from a workforce management tool currently in use by the National Aeronautics and Space Administration. Using data from 26 smallscale software development projects, the team skill measures are correlated to 5 software product quality metrics from the ISO/IEC 9126 Software Engineering Product Quality standard. in the analysis of the results, development team skill is found to be a significant factor in the adequacy of the design and implementation. In addition, the results imply that inexperienced software developers are tasked with responsibilities ill-suited to their skill level, and thus have a significant adverse effect on the quality of the software product. Keywords: software quality, development skill, software metrics</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/19950021464','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/19950021464"><span>A summary of computational experience at GE Aircraft Engines for complex turbulent flows in gas turbines</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Zerkle, Ronald D.; Prakash, Chander</p> <p>1995-01-01</p> <p>This viewgraph presentation summarizes some CFD experience at GE Aircraft Engines for flows in the primary gaspath of a gas turbine engine and in turbine blade cooling passages. It is concluded that application of the standard k-epsilon turbulence model with wall functions is not adequate for accurate CFD simulation of aerodynamic performance and heat transfer in the primary gas path of a gas turbine engine. New models are required in the near-wall region which include more physics than wall functions. The two-layer modeling approach appears attractive because of its computational complexity. In addition, improved CFD simulation of film cooling and turbine blade internal cooling passages will require anisotropic turbulence models. New turbulence models must be practical in order to have a significant impact on the engine design process. A coordinated turbulence modeling effort between NASA centers would be beneficial to the gas turbine industry.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://adsabs.harvard.edu/abs/2017PhRvD..96i5014C','NASAADS'); return false;" href="http://adsabs.harvard.edu/abs/2017PhRvD..96i5014C"><span>Neutrinos in large extra dimensions and short-baseline νe appearance</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://adsabs.harvard.edu/abstract_service.html">NASA Astrophysics Data System (ADS)</a></p> <p>Carena, Marcela; Li, Ying-Ying; Machado, Camila S.; Machado, Pedro A. N.; Wagner, Carlos E. M.</p> <p>2017-11-01</p> <p>We show that, in the presence of bulk masses, sterile neutrinos propagating in large extra dimensions (LED) can induce electron-neutrino appearance effects. This is in contrast to what happens in the standard LED scenario, and hence LED models with explicit bulk masses have the potential to address the MiniBooNE and LSND appearance results as well as the reactor and Gallium anomalies. A special feature in our scenario is that the mixing of the first Kaluza-Klein modes to active neutrinos can be suppressed, making the contribution of heavier sterile neutrinos to oscillations relatively more important. We study the implications of this neutrino mass generation mechanism for current and future neutrino oscillation experiments and show that the Short Baseline Neutrino Program at Fermilab will be able to efficiently probe such a scenario. In addition, this framework leads to massive Dirac neutrinos and thus precludes any signal in neutrinoless double beta decay experiments.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3852875','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=3852875"><span>The Use of Mock NSF-type Grant Proposals and Blind Peer Review as the Capstone Assignment in Upper-Level Neurobiology and Cell Biology Courses</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Itagaki, Haruhiko</p> <p>2013-01-01</p> <p>Although the use of grant proposals and blind peer review are standard in the natural sciences, their use as a pedagogical tool is rarely mentioned in the literature. As a consequence of dissatisfaction with term papers and literature reviews as the capstone writing experience in 300-level undergraduate biology courses, I have been experimenting with mock NSF-type grant proposals followed by blind peer review as the major assignment in my junior/senior-level classes. The improvement in educational outcomes and competencies due to this assignment appears to be substantial and worth the additional effort on both the students’ and instructor’s parts. Here, I outline the mechanics of this assignment and its advantages and disadvantages as well as the type of curriculum that is required to support this type of capstone assignment. PMID:24319395</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=320541','PMC'); return false;" href="https://www.pubmedcentral.nih.gov/articlerender.fcgi?tool=pmcentrez&artid=320541"><span>Characterization of two new plasmid DNAs found in mitochondria of wild-type Neurospora intermedia strains.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?DB=pmc">PubMed Central</a></p> <p>Stohl, L L; Collins, R A; Cole, M D; Lambowitz, A M</p> <p>1982-01-01</p> <p>Mitochondria from two Neurospora intermedia strains (P4O5-Labelle and Fiji N6-6) were found to contain plasmid DNAs in addition to the standard mitochondrial DNA species. The plasmid DNAs consist of monomeric circles (4.1-4.3 kbp and 5.2-5.3 kbp for Labelle and Fiji, respectively) and oligomers in which monomers are organized as head-to-tail repeats. DNA-DNA hybridization experiments showed that the plasmids have no substantial sequence homology to mtDNA, to each other, or to a previously characterized mitochondrial plasmid from N. crassa strain Mauriceville-lc (Collins et al. Cell 24, 443-452, 1981). The intramitochondrial location of the plasmids was established by cell fractionation and nuclease protection experiments. In sexual crosses, the plasmids showed strict maternal inheritance, the same as Neurospora mitochondrial DNA. The plasmids may represent a novel class of mitochondrial genetic elements. Images PMID:6280144</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('http://hdl.handle.net/2060/20120012555','NASA-TRS'); return false;" href="http://hdl.handle.net/2060/20120012555"><span>Extreme Ultraviolet Variability Experiment (EVE) Multiple EUV Grating Spectrographs (MEGS): Radiometric Calibrations and Results</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://ntrs.nasa.gov/search.jsp">NASA Technical Reports Server (NTRS)</a></p> <p>Hock, R. A.; Woods, T. N.; Crotser, D.; Eparvier, F. G.; Woodraska, D. L.; Chamberlin, P. C.; Woods, E. C.</p> <p>2010-01-01</p> <p>The NASA Solar Dynamics Observatory (SDO), scheduled for launch in early 2010, incorporates a suite of instruments including the Extreme Ultraviolet Variability Experiment (EVE). EVE has multiple instruments including the Multiple Extreme ultraviolet Grating Spectrographs (MEGS) A, B, and P instruments, the Solar Aspect Monitor (SAM), and the Extreme ultraviolet SpectroPhotometer (ESP). The radiometric calibration of EVE, necessary to convert the instrument counts to physical units, was performed at the National Institute of Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF III) located in Gaithersburg, Maryland. This paper presents the results and derived accuracy of this radiometric calibration for the MEGS A, B, P, and SAM instruments, while the calibration of the ESP instrument is addressed by Didkovsky et al. . In addition, solar measurements that were taken on 14 April 2008, during the NASA 36.240 sounding-rocket flight, are shown for the prototype EVE instruments.</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.gpo.gov/fdsys/pkg/FR-2011-02-25/pdf/2011-4228.pdf','FEDREG'); return false;" href="https://www.gpo.gov/fdsys/pkg/FR-2011-02-25/pdf/2011-4228.pdf"><span>76 FR 10482 - Special Conditions: Boeing Model 787-8 Airplane; Overhead Flightcrew-Rest Compartment Occupiable...</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.gpo.gov/fdsys/browse/collection.action?collectionCode=FR">Federal Register 2010, 2011, 2012, 2013, 2014</a></p> <p></p> <p>2011-02-25</p> <p>... Boeing Model 787-8 airplane. This airplane will have novel or unusual design features associated with an... standards for this design feature. These special conditions contain the additional safety standards that the... airworthiness standards. Additional special conditions will be issued for other novel or unusual design features...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.gpo.gov/fdsys/pkg/CFR-2011-title40-vol20/pdf/CFR-2011-title40-vol20-sec91-509.pdf','CFR2011'); return false;" href="https://www.gpo.gov/fdsys/pkg/CFR-2011-title40-vol20/pdf/CFR-2011-title40-vol20-sec91-509.pdf"><span>40 CFR 91.509 - Calculation and reporting of test results.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.gpo.gov/fdsys/browse/collectionCfr.action?selectedYearFrom=2011&page.go=Go">Code of Federal Regulations, 2011 CFR</a></p> <p></p> <p>2011-07-01</p> <p>... applicable emission standard expressed to one additional significant figure. (ASTM E29-93a has been... contained in the applicable standard expressed to one additional significant figure. (c) The final... expressed to one additional significant figure. (d) If, at any time during the model year, the CumSum...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.gpo.gov/fdsys/pkg/CFR-2014-title40-vol20/pdf/CFR-2014-title40-vol20-sec91-509.pdf','CFR2014'); return false;" href="https://www.gpo.gov/fdsys/pkg/CFR-2014-title40-vol20/pdf/CFR-2014-title40-vol20-sec91-509.pdf"><span>40 CFR 91.509 - Calculation and reporting of test results.</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.gpo.gov/fdsys/browse/collectionCfr.action?selectedYearFrom=2014&page.go=Go">Code of Federal Regulations, 2014 CFR</a></p> <p></p> <p>2014-07-01</p> <p>... applicable emission standard expressed to one additional significant figure. (ASTM E29-93a has been... contained in the applicable standard expressed to one additional significant figure. (c) The final... expressed to one additional significant figure. (d) If, at any time during the model year, the CumSum...</p> </li> <li> <p><a target="_blank" rel="noopener noreferrer" onclick="trackOutboundLink('https://www.gpo.gov/fdsys/pkg/FR-2013-12-20/pdf/2013-30428.pdf','FEDREG'); return false;" href="https://www.gpo.gov/fdsys/pkg/FR-2013-12-20/pdf/2013-30428.pdf"><span>78 FR 77119 - Proposed Information Collection Request; Comment Request; Regulation of Fuels and Fuel Additives...</span></a></p> <p><a target="_blank" rel="noopener noreferrer" href="http://www.gpo.gov/fdsys/browse/collection.action?collectionCode=FR">Federal Register 2010, 2011, 2012, 2013, 2014</a></p> <p></p> <p>2013-12-20</p> <p>... Collection Request; Comment Request; Regulation of Fuels and Fuel Additives: 2011 Renewable Fuel Standards... collection request (ICR), ``Regulation of Fuels and Fuel Additives: 2011 Renewable Fuel Standards--Petition... whose disclosure is restricted by statute. FOR FURTHER INFORMATION CONTACT: Geanetta Heard, Fuels...</p> </li> </ol> <div class="pull-right"> <ul class="pagination"> <li><a href="#" onclick='return showDiv("page_1");'>«</a></li> <li><a href="#" onclick='return showDiv("page_21");'>21</a></li> <li><a href="#" onclick='return showDiv("page_22");'>22</a></li> <li><a href="#" onclick='return showDiv("page_23");'>23</a></li> <li><a href="#" onclick='return showDiv("page_24");'>24</a></li> <li class="active"><span>25</span></li> <li><a href="#" onclick='return showDiv("page_25");'>»</a></li> </ul> </div> </div><!-- col-sm-12 --> </div><!-- row --> </div><!-- page_25 --> <div class="footer-extlink text-muted" style="margin-bottom:1rem; text-align:center;">Some links on this page may take you to non-federal websites. Their policies may differ from this site.</div> </div><!-- container --> <a id="backToTop" href="#top"> Top </a> <footer> <nav> <ul class="links"> <li><a href="/sitemap.html">Site Map</a></li> <li><a href="/website-policies.html">Website Policies</a></li> <li><a href="https://www.energy.gov/vulnerability-disclosure-policy" target="_blank">Vulnerability Disclosure Program</a></li> <li><a href="/contact.html">Contact Us</a></li> </ul> </nav> </footer> <script type="text/javascript"><!-- // var lastDiv = ""; function showDiv(divName) { // hide last div if (lastDiv) { document.getElementById(lastDiv).className = "hiddenDiv"; } //if value of the box is not nothing and an object with that name exists, then change the class if (divName && document.getElementById(divName)) { document.getElementById(divName).className = "visibleDiv"; lastDiv = divName; } } //--> </script> <script> /** * Function that tracks a click on an outbound link in Google Analytics. * This function takes a valid URL string as an argument, and uses that URL string * as the event label. */ var trackOutboundLink = function(url,collectionCode) { try { h = window.open(url); setTimeout(function() { ga('send', 'event', 'topic-page-click-through', collectionCode, url); }, 1000); } catch(err){} }; </script> <!-- Google Analytics --> <script> (function(i,s,o,g,r,a,m){i['GoogleAnalyticsObject']=r;i[r]=i[r]||function(){ (i[r].q=i[r].q||[]).push(arguments)},i[r].l=1*new Date();a=s.createElement(o), m=s.getElementsByTagName(o)[0];a.async=1;a.src=g;m.parentNode.insertBefore(a,m) })(window,document,'script','//www.google-analytics.com/analytics.js','ga'); ga('create', 'UA-1122789-34', 'auto'); ga('send', 'pageview'); </script> <!-- End Google Analytics --> <script> showDiv('page_1') </script> </body> </html>