  1. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF VOLATILE ORGANIC COMPOUNDS COLLECTED WITH A PASSIVE SAMPLER (BCO-L-17.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methodology used for the analysis of the 3M OVM 3500 Organic Vapor Monitors for volatile organic compounds (VOCs), using solvent extraction and standard gas chromatography/mass spectrometry (GC/MS) analysis procedures. This procedure was...

  2. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR NEUTRAL TARGET ANALYTES (SOP-5.25)

    EPA Science Inventory

    This standard operating procedure describes the method used for preparing internal standard, surrogate recovery standard and calibration standard solutions for neutral analytes used for gas chromatography/mass spectrometry analysis.

  3. Bio-Oil Analysis Laboratory Procedures | Bioenergy | NREL

    Science.gov Websites

    Bio-Oil Analysis Laboratory Procedures Bio-Oil Analysis Laboratory Procedures NREL develops standard procedures have been validated and allow for reliable bio-oil analysis. Procedures Determination different hydroxyl groups (-OH) in pyrolysis bio-oil: aliphatic-OH, phenolic-OH, and carboxylic-OH. Download

  4. AgRISTARS: Foreign Commodity production forecasting. Project procedures designation and description document, volume 1

    NASA Technical Reports Server (NTRS)

    Waggoner, J. T.; Phinney, D. E. (Principal Investigator)

    1981-01-01

    The crop estimation analysis procedures documentation of the AgRISTARS - Foreign Commodity Production Forecasting Project (FCPF) is presented. Specifically it includes the technical/management documentation of the remote sensing data analysis procedures prepared in accordance with the guidelines provided in the FCPF communication/documentation standards manual. Standard documentation sets are given arranged by procedural type and level then by crop types or other technically differentiating categories.

  5. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING DERMAL WIPE AND SURFACE WIPE SAMPLES FOR ANALYSIS OF POLAR ORGANIC POLLUTANTS (SOP-5.27)

    EPA Science Inventory

    The method for extracting and preparing a dermal or surface wipe sample for analysis of acidic persistent organic pollutants is summarized in this standard operating procedure. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mas...

  6. Using normalization 3D model for automatic clinical brain quantative analysis and evaluation

    NASA Astrophysics Data System (ADS)

    Lin, Hong-Dun; Yao, Wei-Jen; Hwang, Wen-Ju; Chung, Being-Tau; Lin, Kang-Ping

    2003-05-01

    Functional medical imaging, such as PET or SPECT, is capable of revealing physiological functions of the brain, and has been broadly used in diagnosing brain disorders by clinically quantitative analysis for many years. In routine procedures, physicians manually select desired ROIs from structural MR images and then obtain physiological information from correspondent functional PET or SPECT images. The accuracy of quantitative analysis thus relies on that of the subjectively selected ROIs. Therefore, standardizing the analysis procedure is fundamental and important in improving the analysis outcome. In this paper, we propose and evaluate a normalization procedure with a standard 3D-brain model to achieve precise quantitative analysis. In the normalization process, the mutual information registration technique was applied for realigning functional medical images to standard structural medical images. Then, the standard 3D-brain model that shows well-defined brain regions was used, replacing the manual ROIs in the objective clinical analysis. To validate the performance, twenty cases of I-123 IBZM SPECT images were used in practical clinical evaluation. The results show that the quantitative analysis outcomes obtained from this automated method are in agreement with the clinical diagnosis evaluation score with less than 3% error in average. To sum up, the method takes advantage of obtaining precise VOIs, information automatically by well-defined standard 3-D brain model, sparing manually drawn ROIs slice by slice from structural medical images in traditional procedure. That is, the method not only can provide precise analysis results, but also improve the process rate for mass medical images in clinical.

  7. Stormwater Characterization and Lagoon Sediment Analysis, Grand Forks Air Force Base, North Dakota

    DTIC Science & Technology

    1990-08-01

    tetrachloroethylene, and 0.0026 mg/l ethyl benzene. Analyses showed no pesticides . 4. Extraction Procedure (EP) Analysis. An AFOEHL contractor performed EP extraction ...runoff met North Dakota state stream standards. Lagoon sediment did not contain Extraction Procedure hazardous chemicals. Stormwater runoff exceeded...Standards for Water Quality for the State of North Dakota ( Extracts ) 39 D Site/Analysis Summary 69 E Lift Station Flow Records 73 F Wastewater

  8. Development of a standard operating procedure for analysis of ammonia concentrations in coal fly ash.

    DOT National Transportation Integrated Search

    2015-04-01

    Research was performed to support the development and recommendation of a standard operating : procedure (SOP) for analyzing the ammonia content in fly ash intended for use in concrete. A review : of existing ash producers found that several differen...

  9. Development of a standard operating procedure for the collection of pyrethroids in water and sediment matrices

    EPA Science Inventory

    Through a Regional Applied Research Effort grant to the United States Geological Survey, Region 9 collaborated with ORD on this project to develop a standard operating procedure for collection of water and sediment samples for pyrethroid analysis.

  10. Computing tools for implementing standards for single-case designs.

    PubMed

    Chen, Li-Ting; Peng, Chao-Ying Joanne; Chen, Ming-E

    2015-11-01

    In the single-case design (SCD) literature, five sets of standards have been formulated and distinguished: design standards, assessment standards, analysis standards, reporting standards, and research synthesis standards. This article reviews computing tools that can assist researchers and practitioners in meeting the analysis standards recommended by the What Works Clearinghouse: Procedures and Standards Handbook-the WWC standards. These tools consist of specialized web-based calculators or downloadable software for SCD data, and algorithms or programs written in Excel, SAS procedures, SPSS commands/Macros, or the R programming language. We aligned these tools with the WWC standards and evaluated them for accuracy and treatment of missing data, using two published data sets. All tools were tested to be accurate. When missing data were present, most tools either gave an error message or conducted analysis based on the available data. Only one program used a single imputation method. This article concludes with suggestions for an inclusive computing tool or environment, additional research on the treatment of missing data, and reasonable and flexible interpretations of the WWC standards. © The Author(s) 2015.

  11. A Comparison of Approaches for Setting Proficiency Standards.

    ERIC Educational Resources Information Center

    Koffler, Stephen L.

    This research compared the cut-off scores estimated from an empirical procedure (Contrasting group method) to those determined from a more theoretical process (Nedelsky method). A methodological and statistical framework was also provided for analysis of the data to obtain the most appropriate standard using the empirical procedure. Data were…

  12. 21 CFR 120.6 - Sanitation standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 2 2014-04-01 2014-04-01 false Sanitation standard operating procedures. 120.6 Section 120.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General...

  13. 21 CFR 120.6 - Sanitation standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 2 2012-04-01 2012-04-01 false Sanitation standard operating procedures. 120.6 Section 120.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General...

  14. Description of the testing process for the Automated Residential Energy Standard (ARES) in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    In this report, the scope of the tests, the method of analysis, the results, and the conclusions are discussed. The first test indicated that the requirements generated by the Standard procedures and formulae appear to yield reasonable results, although some of the cost data provided as defaults in the Standard should be reevaluated. The second test provided experience that was useful in modifying the points compliance format, but did not uncover any procedural issues that would lead to unreasonable results. These conclusions are based on analysis using the Automated Residential Energy Standard (ARES) computer program, developed to simplify the processmore » of standards generation.« less

  15. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less

  16. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less

  17. Effects of Computer-Based Training on Procedural Modifications to Standard Functional Analyses

    ERIC Educational Resources Information Center

    Schnell, Lauren K.; Sidener, Tina M.; DeBar, Ruth M.; Vladescu, Jason C.; Kahng, SungWoo

    2018-01-01

    Few studies have evaluated methods for training decision-making when functional analysis data are undifferentiated. The current study evaluated computer-based training to teach 20 graduate students to arrange functional analysis conditions, analyze functional analysis data, and implement procedural modifications. Participants were exposed to…

  18. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF SOIL/HOUSE DUST FOR GC/MS ANALYSIS OF PESTICIDES (BCO-L-14.0)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for extracting and preparing dust or soil samples for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "...

  19. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF PESTICIDES FROM SURFACE WIPE SAMPLES (BCO-L-13.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for extracting and preparing a sill surface wipe sample for gas chromatography/mass spectrometry (GC/MS) analysis of pesticides. This procedure is also used for the pre-shipment analysis of sill wipe samples for materials sui...

  20. Randomization Procedures Applied to Analysis of Ballistic Data

    DTIC Science & Technology

    1991-06-01

    test,;;15. NUMBER OF PAGES data analysis; computationally intensive statistics ; randomization tests; permutation tests; 16 nonparametric statistics ...be 0.13. 8 Any reasonable statistical procedure would fail to support the notion of improvement of dynamic over standard indexing based on this data ...AD-A238 389 TECHNICAL REPORT BRL-TR-3245 iBRL RANDOMIZATION PROCEDURES APPLIED TO ANALYSIS OF BALLISTIC DATA MALCOLM S. TAYLOR BARRY A. BODT - JUNE

  1. Modified procedure to determine acid-insoluble lignin in wood and pulp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Effland, M.J.

    1977-10-01

    If wood is treated with strong acid, carbohydrates are hydrolyzed and solubilized. The insoluble residue is by definition lignin and can be measured gravimetrically. The standard method of analysis requires samples of 1 or 2 g of wood or pulp. In research at this laboratory these amounts of sample are often not available for analytical determinations. Thus we developed a modification of the standard procedure suitable for much smaller sample amounts. The modification is based on the procedure of Saeman. Wood samples require extraction prior to lignin analysis to remove acid-insoluble extractives that will be measured as lignin. Usually thismore » involves only a standard extraction with ethanol--benzene. However, woods high in tannin must also be subjected to extraction with alcohol. Pulps seldom require extraction.« less

  2. Standard Operating Procedure for Surface Paint Sample Collection using a Modified Wood Drill Bit with a Variable Speed Portable Electric Drill

    EPA Science Inventory

    This standard operating procedure (SOP) describes a new, rapid, and relatively inexpensive way to remove a precise area of paint from the substrate of building structures in preparation for quantitative analysis. This method has been applied successfully in the laboratory, as we...

  3. Analysis of simulated angiographic procedures. Part 2: extracting efficiency data from audio and video recordings.

    PubMed

    Duncan, James R; Kline, Benjamin; Glaiberman, Craig B

    2007-04-01

    To create and test methods of extracting efficiency data from recordings of simulated renal stent procedures. Task analysis was performed and used to design a standardized testing protocol. Five experienced angiographers then performed 16 renal stent simulations using the Simbionix AngioMentor angiographic simulator. Audio and video recordings of these simulations were captured from multiple vantage points. The recordings were synchronized and compiled. A series of efficiency metrics (procedure time, contrast volume, and tool use) were then extracted from the recordings. The intraobserver and interobserver variability of these individual metrics was also assessed. The metrics were converted to costs and aggregated to determine the fixed and variable costs of a procedure segment or the entire procedure. Task analysis and pilot testing led to a standardized testing protocol suitable for performance assessment. Task analysis also identified seven checkpoints that divided the renal stent simulations into six segments. Efficiency metrics for these different segments were extracted from the recordings and showed excellent intra- and interobserver correlations. Analysis of the individual and aggregated efficiency metrics demonstrated large differences between segments as well as between different angiographers. These differences persisted when efficiency was expressed as either total or variable costs. Task analysis facilitated both protocol development and data analysis. Efficiency metrics were readily extracted from recordings of simulated procedures. Aggregating the metrics and dividing the procedure into segments revealed potential insights that could be easily overlooked because the simulator currently does not attempt to aggregate the metrics and only provides data derived from the entire procedure. The data indicate that analysis of simulated angiographic procedures will be a powerful method of assessing performance in interventional radiology.

  4. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS ANALYSIS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHODS FOR ANALYSIS OF TRACE METALS AND PESTICIDES IN DIETARY SAMPLES USING TOTAL DIET STUDY PROCEDURES (FDA-COMPENDIUM)

    EPA Science Inventory

    This compendium contains seven SOPs developed by Food and Drug Administration (FDA) laboratories for methods of analyzing trace metals in dietary samples collected using Total Diet study procedures. The SOPs include the following: (1) Quality Control for Analysis of NHEXAS Food o...

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF SOIL AND HOUSE DUST SAMPLES FOR GC/MS ANALYSIS OF PESTICIDE AND PAH (BCO-L-28.0)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for extracting and preparing a dust or soil sample for gas chromatography mass spectrometry (GC/MS) analysis of pesticides and polyaromatic hydrocarbons (PAHs). This procedure was followed to ensure consistent data retrieval durin...

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF AIR SAMPLES FOR GC/MS ANALYSIS OF PESTICIDES (BCO-L-11.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for extracting and preparing an air sample consisting of a polyurethane foam (PUF) plug and Teflon-coated glass fiber filter (Pallflex T60A20) for analysis of pesticides. This procedure covers sample preparation for samples t...

  8. Methodology for estimation of total body composition in laboratory mammals

    NASA Technical Reports Server (NTRS)

    Pace, N.; Rahlmann, D. F.; Smith, A. H.

    1979-01-01

    A standardized dissection and chemical analysis procedure was developed for individual animals of several species in the size range mouse to monkey (15 g to 15 kg). The standardized procedure permits rigorous comparisons to be made both interspecifically and intraspecifically of organ weights and gross chemical composition in mammalian species series, and was applied successfully to laboratory mice, hamsters, rats, guinea pigs, and rabbits, as well as to macaque monkeys. The procedure is described in detail.

  9. Analysis of Students' Assessments in Middle School Curriculum Materials: Aiming Precisely at Benchmarks and Standards.

    ERIC Educational Resources Information Center

    Stern, Luli; Ahlgren, Andrew

    2002-01-01

    Project 2061 of the American Association for the Advancement of Science (AAAS) developed and field-tested a procedure for analyzing curriculum materials, including assessments, in terms of contribution to the attainment of benchmarks and standards. Using this procedure, Project 2061 produced a database of reports on nine science middle school…

  10. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR THE RECEIPT OF SAMPLES OR REFERENCE COMPOUNDS FOR LABORATORY ANALYSIS AT BATTELLE (BCO-G-2.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the steps to be taken when field samples are received at Battelle Laboratory for further analysis. The procedure provides for the log-in, initial processing (if required), and distribution of the sample. Procedures concerning the sample Ch...

  11. Methodological Choices in the Content Analysis of Textbooks for Measuring Alignment with Standards

    ERIC Educational Resources Information Center

    Polikoff, Morgan S.; Zhou, Nan; Campbell, Shauna E.

    2015-01-01

    With the recent adoption of the Common Core standards in many states, there is a need for quality information about textbook alignment to standards. While there are many existing content analysis procedures, these generally have little, if any, validity or reliability evidence. One exception is the Surveys of Enacted Curriculum (SEC), which has…

  12. Basin F Overburden and Soil Sampling and Analysis Study, Rocky Mountain Arsenal

    DTIC Science & Technology

    1982-05-01

    boring sites will be es:ablished via standard :and surveyinS procedures. 3.3 Bor-ng/ Samaling Procidures Upon staking/marking of the bore holes, the folloi...procedure until the interferences have been eliminated. 3.2.2 Samale Testing Step OC (6) (Procedure Blank) The procedure blank consists of the

  13. 40 CFR 131.21 - EPA review and approval of water quality standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS WATER QUALITY STANDARDS Procedures for Review and Revision of Water Quality Standards § 131.21 EPA review and approval of water quality standards. (a) After the State submits its... analysis. (b) The Regional Administrator's approval or disapproval of a State water quality standard shall...

  14. CTEPP STANDARD OPERATING PROCEDURE FOR PREPARATION OF SURROGATE RECOVERY STANDARD AND INTERNAL STANDARD SOLUTIONS FOR POLAR TARGET ANALYTES (SOP-5.26)

    EPA Science Inventory

    This SOP describes the method used for preparing surrogate recovery standard and internal standard solutions for the analysis of polar target analytes. It also describes the method for preparing calibration standard solutions for polar analytes used for gas chromatography/mass sp...

  15. Optimizing the extraction, storage, and analysis of airborne endotoxins

    USDA-ARS?s Scientific Manuscript database

    While the Limulus amebocyte lysate (LAL) assay is part of most procedures to assess airborne endotoxin exposure, there is no universally agreed upon standard procedure. The purpose of this study was to fill in additional knowledge gaps with respect to the extraction, storage, and analysis of endotox...

  16. Standardization, evaluation and early-phase method validation of an analytical scheme for batch-consistency N-glycosylation analysis of recombinant produced glycoproteins.

    PubMed

    Zietze, Stefan; Müller, Rainer H; Brecht, René

    2008-03-01

    In order to set up a batch-to-batch-consistency analytical scheme for N-glycosylation analysis, several sample preparation steps including enzyme digestions and fluorophore labelling and two HPLC-methods were established. The whole method scheme was standardized, evaluated and validated according to the requirements on analytical testing in early clinical drug development by usage of a recombinant produced reference glycoprotein (RGP). The standardization of the methods was performed by clearly defined standard operation procedures. During evaluation of the methods, the major interest was in the loss determination of oligosaccharides within the analytical scheme. Validation of the methods was performed with respect to specificity, linearity, repeatability, LOD and LOQ. Due to the fact that reference N-glycan standards were not available, a statistical approach was chosen to derive accuracy from the linearity data. After finishing the validation procedure, defined limits for method variability could be calculated and differences observed in consistency analysis could be separated into significant and incidental ones.

  17. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  18. Standardization and program effect analysis (Study 2.4). Volume 3: Design-to-cost analysis

    NASA Technical Reports Server (NTRS)

    Shiokari, T.

    1975-01-01

    The program procedures that were incorporated into an on-going "design-to-cost" spacecraft program are examined. Program procedures are the activities that support the development and operations of the flight unit: contract management, documents, integration meetings, engineering, and testing. This report is limited to the program procedures that were implemented, with emphasis on areas that may depart from normal satellite development practices.

  19. Quality control and assurance for validation of DOS/I measurements

    NASA Astrophysics Data System (ADS)

    Cerussi, Albert; Durkin, Amanda; Kwong, Richard; Quang, Timothy; Hill, Brian; Tromberg, Bruce J.; MacKinnon, Nick; Mantulin, William W.

    2010-02-01

    Ongoing multi-center clinical trials are crucial for Biophotonics to gain acceptance in medical imaging. In these trials, quality control (QC) and assurance (QA) are key to success and provide "data insurance". Quality control and assurance deal with standardization, validation, and compliance of procedures, materials and instrumentation. Specifically, QC/QA involves systematic assessment of testing materials, instrumentation performance, standard operating procedures, data logging, analysis, and reporting. QC and QA are important for FDA accreditation and acceptance by the clinical community. Our Biophotonics research in the Network for Translational Research in Optical Imaging (NTROI) program for breast cancer characterization focuses on QA/QC issues primarily related to the broadband Diffuse Optical Spectroscopy and Imaging (DOS/I) instrumentation, because this is an emerging technology with limited standardized QC/QA in place. In the multi-center trial environment, we implement QA/QC procedures: 1. Standardize and validate calibration standards and procedures. (DOS/I technology requires both frequency domain and spectral calibration procedures using tissue simulating phantoms and reflectance standards, respectively.) 2. Standardize and validate data acquisition, processing and visualization (optimize instrument software-EZDOS; centralize data processing) 3. Monitor, catalog and maintain instrument performance (document performance; modularize maintenance; integrate new technology) 4. Standardize and coordinate trial data entry (from individual sites) into centralized database 5. Monitor, audit and communicate all research procedures (database, teleconferences, training sessions) between participants ensuring "calibration". This manuscript describes our ongoing efforts, successes and challenges implementing these strategies.

  20. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR EXPLORATORY DATA ANALYSIS AND SUMMARY STATISTICS (D05)

    EPA Science Inventory

    This SOP describes the methods and procedures for two types of QA procedures: spot checks of hand entered data, and QA procedures for co-located and split samples. The spot checks were used to determine whether the error rate goal for the input of hand entered data was being att...

  1. Evaluation of human exposure to complex waveform magnetic fields generated by arc-welding equipment according to European safety standards.

    PubMed

    Zoppetti, Nicola; Bogi, Andrea; Pinto, Iole; Andreuccetti, Daniele

    2015-02-01

    In this paper, a procedure is described for the assessment of human exposure to magnetic fields with complex waveforms generated by arc-welding equipment. The work moves from the analysis of relevant guidelines and technical standards, underlining their strengths and their limits. Then, the procedure is described with particular attention to the techniques used to treat complex waveform fields. Finally, the procedure is applied to concrete cases encountered in the workplace. The discussion of the results highlights the critical points in the procedure, as well as those related to the evolution of the technical and exposure standards. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. 40 CFR 792.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... according to written standard operating procedures, which provide for periodic analysis of each batch. (b... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances...

  3. 40 CFR 792.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... according to written standard operating procedures, which provide for periodic analysis of each batch. (b... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances...

  4. 40 CFR 792.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... according to written standard operating procedures, which provide for periodic analysis of each batch. (b... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances...

  5. 40 CFR 792.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... according to written standard operating procedures, which provide for periodic analysis of each batch. (b... SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances...

  6. Statistical Assessment of Variability of Terminal Restriction Fragment Length Polymorphism Analysis Applied to Complex Microbial Communities ▿ †

    PubMed Central

    Rossi, Pierre; Gillet, François; Rohrbach, Emmanuelle; Diaby, Nouhou; Holliger, Christof

    2009-01-01

    The variability of terminal restriction fragment polymorphism analysis applied to complex microbial communities was assessed statistically. Recent technological improvements were implemented in the successive steps of the procedure, resulting in a standardized procedure which provided a high level of reproducibility. PMID:19749066

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PASSIVE FORMALDEHYDE SAMPLERS (BCO-L-16.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the methodology used by Air Quality Research (Research Triangle Park, NC) for the analysis of the PF-1 passive formaldehyde samplers using a colorimetric method and chromotropic acid. This procedure was followed to ensure consistent data re...

  8. Cross-Cultural Validation of the Patient Perception of Integrated Care Survey.

    PubMed

    Tietschert, Maike V; Angeli, Federica; van Raak, Arno J A; Ruwaard, Dirk; Singer, Sara J

    2017-07-20

    To test the cross-cultural validity of the U.S. Patient Perception of Integrated Care (PPIC) Survey in a Dutch sample using a standardized procedure. Primary data collected from patients of five primary care centers in the south of the Netherlands, through survey research from 2014 to 2015. Cross-sectional data collected from patients who saw multiple health care providers during 6 months preceding data collection. The PPIC survey includes 59 questions that measure patient perceived care integration across providers, settings, and time. Data analysis followed a standardized procedure guiding data preparation, psychometric analysis, and included invariance testing with the U.S. dataset. Latent scale structures of the Dutch and U.S. survey were highly comparable. Factor "Integration with specialist" had lower reliability scores and noninvariance. For the remaining factors, internal consistency and invariance estimates were strong. The standardized cross-cultural validation procedure produced strong support for comparable psychometric characteristics of the Dutch and U.S. surveys. Future research should examine the usability of the proposed procedure for contexts with greater cultural differences. © Health Research and Educational Trust.

  9. A search for radiative neutrino decay from supernovae

    NASA Technical Reports Server (NTRS)

    Miller, Richard S.; Svoboda, Robert C.

    1993-01-01

    This document presents the data analysis procedures proposed for use with the COMPTEL instrument aboard the Compton Gamma Ray Observatory (GRO) in the search for radiative neutrino decay from supernovae. The proposed analysis methodology is an extension of a standard procedure used by the COMPTEL team in searching for a variety of source types. We have applied the procedures to a set of simulated data to demonstrate the feasibility of the method to this project.

  10. 40 CFR 260.11 - References.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...). (7) ASTM E 168-88, “Standard Practices for General Techniques of Infrared Quantitative Analysis,” IBR...-Visible Quantitative Analysis,” IBR approved for § 264.1063. (9) ASTM E 260-85, “Standard Practice for..., Research Triangle Park, NC. (1) “Screening Procedures for Estimating the Air Quality Impact of Stationary...

  11. 40 CFR 260.11 - References.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...). (7) ASTM E 168-88, “Standard Practices for General Techniques of Infrared Quantitative Analysis,” IBR...-Visible Quantitative Analysis,” IBR approved for § 264.1063. (9) ASTM E 260-85, “Standard Practice for..., Research Triangle Park, NC. (1) “Screening Procedures for Estimating the Air Quality Impact of Stationary...

  12. 40 CFR 260.11 - References.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...). (7) ASTM E 168-88, “Standard Practices for General Techniques of Infrared Quantitative Analysis,” IBR...-Visible Quantitative Analysis,” IBR approved for § 264.1063. (9) ASTM E 260-85, “Standard Practice for..., Research Triangle Park, NC. (1) “Screening Procedures for Estimating the Air Quality Impact of Stationary...

  13. 40 CFR 160.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... concomitantly according to written standard operating procedures, which provide for periodic analysis of each...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.105 Test...

  14. 40 CFR 160.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... concomitantly according to written standard operating procedures, which provide for periodic analysis of each...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.105 Test...

  15. 40 CFR 160.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... concomitantly according to written standard operating procedures, which provide for periodic analysis of each...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.105 Test...

  16. 40 CFR 160.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standard operating procedures, which provide for periodic analysis of each batch. (b) Where any of the...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.113...

  17. 40 CFR 160.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... concomitantly according to written standard operating procedures, which provide for periodic analysis of each...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.105 Test...

  18. 40 CFR 160.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standard operating procedures, which provide for periodic analysis of each batch. (b) Where any of the...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.113...

  19. 40 CFR 160.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard operating procedures, which provide for periodic analysis of each batch. (b) Where any of the...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.113...

  20. 40 CFR 160.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standard operating procedures, which provide for periodic analysis of each batch. (b) Where any of the...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.113...

  1. 40 CFR 160.113 - Mixtures of substances with carriers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standard operating procedures, which provide for periodic analysis of each batch. (b) Where any of the...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.113...

  2. 40 CFR 160.105 - Test, control, and reference substance characterization.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... concomitantly according to written standard operating procedures, which provide for periodic analysis of each...) PESTICIDE PROGRAMS GOOD LABORATORY PRACTICE STANDARDS Test, Control, and Reference Substances § 160.105 Test...

  3. Evaluation of flaws in carbon steel piping. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zahoor, A.; Gamble, R.M.; Mehta, H.S.

    1986-10-01

    The objective of this program was to develop flaw evaluation procedures and allowable flaw sizes for ferritic piping used in light water reactor (LWR) power generation facilities. The program results provide relevant ASME Code groups with the information necessary to define flaw evaluation procedures, allowable flaw sizes, and their associated bases for Section XI of the code. Because there are several possible flaw-related failure modes for ferritic piping over the LWR operating temperature range, three analysis methods were employed to develop the evaluation procedures. These include limit load analysis for plastic collapse, elastic plastic fracture mechanics (EPFM) analysis for ductilemore » tearing, and linear elastic fracture mechanics (LEFM) analysis for non ductile crack extension. To ensure the appropriate analysis method is used in an evaluation, a step by step procedure also is provided to identify the relevant acceptance standard or procedure on a case by case basis. The tensile strength and toughness properties required to complete the flaw evaluation for any of the three analysis methods are included in the evaluation procedure. The flaw evaluation standards are provided in tabular form for the plastic collapse and ductile tearing modes, where the allowable part through flaw depth is defined as a function of load and flaw length. For non ductile crack extension, linear elastic fracture mechanics analysis methods, similar to those in Appendix A of Section XI, are defined. Evaluation flaw sizes and procedures are developed for both longitudinal and circumferential flaw orientations and normal/upset and emergency/faulted operating conditions. The tables are based on margins on load of 2.77 and 1.39 for circumferential flaws and 3.0 and 1.5 for longitudinal flaws for normal/upset and emergency/faulted conditions, respectively.« less

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ARCHIVE PROCEDURE FOR STUDY SAMPLES (UA-G-4.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the archive/custody guidelines used by the NHEXAS Arizona research project. This procedure was followed to maintain and locate samples, extracts, tracings and hard copy results after laboratory analysis during the Arizona NHEXAS project and ...

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR RECEIPT OF EQUIPMENT AND IMPLEMENTATION SUPPLIES (UA-G-5.0)

    EPA Science Inventory

    The purpose of this SOP is to outline procedures for the receipt of equipment and field implementation supplies at the NHEXAS Arizona research project. This procedure was followed to ensure consistent data custody, storage, transfer, and analysis of a high quality during the Ari...

  6. Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.

    DOT National Transportation Integrated Search

    1987-03-31

    These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...

  7. Development of FWD procedures manual.

    DOT National Transportation Integrated Search

    2010-04-01

    In this project, the state-of-practice in FWD testing and analysis procedures were examined : by looking at the standard protocols of a number of other highway agencies. The specific : needs of NJDOT were also examined and a protocol was developed th...

  8. Standards for the Analysis and Processing of Surface-Water Data and Information Using Electronic Methods

    USGS Publications Warehouse

    Sauer, Vernon B.

    2002-01-01

    Surface-water computation methods and procedures are described in this report to provide standards from which a completely automated electronic processing system can be developed. To the greatest extent possible, the traditional U. S. Geological Survey (USGS) methodology and standards for streamflow data collection and analysis have been incorporated into these standards. Although USGS methodology and standards are the basis for this report, the report is applicable to other organizations doing similar work. The proposed electronic processing system allows field measurement data, including data stored on automatic field recording devices and data recorded by the field hydrographer (a person who collects streamflow and other surface-water data) in electronic field notebooks, to be input easily and automatically. A user of the electronic processing system easily can monitor the incoming data and verify and edit the data, if necessary. Input of the computational procedures, rating curves, shift requirements, and other special methods are interactive processes between the user and the electronic processing system, with much of this processing being automatic. Special computation procedures are provided for complex stations such as velocity-index, slope, control structures, and unsteady-flow models, such as the Branch-Network Dynamic Flow Model (BRANCH). Navigation paths are designed to lead the user through the computational steps for each type of gaging station (stage-only, stagedischarge, velocity-index, slope, rate-of-change in stage, reservoir, tide, structure, and hydraulic model stations). The proposed electronic processing system emphasizes the use of interactive graphics to provide good visual tools for unit values editing, rating curve and shift analysis, hydrograph comparisons, data-estimation procedures, data review, and other needs. Documentation, review, finalization, and publication of records are provided for with the electronic processing system, as well as archiving, quality assurance, and quality control.

  9. A sensitivity analysis comparing two procedures for adjusting as-measured spectra to reference conditions

    DOT National Transportation Integrated Search

    2002-04-01

    The Society of Automotive Engineers (SAE) Aerospace Recommended Practice (ARP) No. 866A (866A), and a : procedure utilizing pure-tone absorption equations developed in support of the International Organization : for Standardizations (ISO) 9613-...

  10. Standardisation of DNA quantitation by image analysis: quality control of instrumentation.

    PubMed

    Puech, M; Giroud, F

    1999-05-01

    DNA image analysis is frequently performed in clinical practice as a prognostic tool and to improve diagnosis. The precision of prognosis and diagnosis depends on the accuracy of analysis and particularly on the quality of image analysis systems. It has been reported that image analysis systems used for DNA quantification differ widely in their characteristics (Thunissen et al.: Cytometry 27: 21-25, 1997). This induces inter-laboratory variations when the same sample is analysed in different laboratories. In microscopic image analysis, the principal instrumentation errors arise from the optical and electronic parts of systems. They bring about problems of instability, non-linearity, and shading and glare phenomena. The aim of this study is to establish tools and standardised quality control procedures for microscopic image analysis systems. Specific reference standard slides have been developed to control instability, non-linearity, shading and glare phenomena and segmentation efficiency. Some systems have been controlled with these tools and these quality control procedures. Interpretation criteria and accuracy limits of these quality control procedures are proposed according to the conclusions of a European project called PRESS project (Prototype Reference Standard Slide). Beyond these limits, tested image analysis systems are not qualified to realise precise DNA analysis. The different procedures presented in this work determine if an image analysis system is qualified to deliver sufficiently precise DNA measurements for cancer case analysis. If the controlled systems are beyond the defined limits, some recommendations are given to find a solution to the problem.

  11. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR PERFORMANCE OF ANALYSES ON NHEXAS DATA (IIT-A-3.0)

    EPA Science Inventory

    The purpose of this SOP is to define the procedures for the analysis of NHEXAS and Border study data. These methods were used for all data analysis associated with the Arizona NHEXAS project and the Border study at the Illinois Institute of Technology (IIT) site. Keywords: data;...

  12. EP-DRAFT-1.1 2014-01-19 OSI-GAM-SOP-00x In Situ High-resolution Gamma Spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wimer, N. G.; Kreek, S. A.

    2014-01-27

    The standard operating procedure is described for in situ high-resolution gamma spectroscopy, including operational readiness, planning, preparation, conduct, and reporting. Data analysis of in situ gamma spectrum files will be performed together with those of other gamma assay methods by a dedicated Data Analysis process, documented in companion OSI procedures.

  13. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF CALIBRATION AND SURROGATE RECOVERY SOLUTIONS FOR GC/MS ANALYSIS OF PESTICIDES (BCO-L-21.1)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for preparing calibration curve solutions used for gas chromatography/mass spectrometry (GC/MS) analysis of chlorpyrifos, diazinon, malathion, DDT, DDE, DDD, a-chlordane, and g-chlordane in dust, soil, air, and handwipe sample ext...

  14. Cognitive Task Analysis of Experts in Designing Multimedia Learning Object Guideline (M-LOG)

    ERIC Educational Resources Information Center

    Razak, Rafiza Abdul; Palanisamy, Punithavathy

    2013-01-01

    The purpose of this study was to design and develop a set of guidelines for multimedia learning objects to inform instructional designers (IDs) about the procedures involved in the process of content analysis. This study was motivated by the absence of standardized procedures in the beginning phase of the multimedia learning object design which is…

  15. Acid Rain Analysis by Standard Addition Titration.

    ERIC Educational Resources Information Center

    Ophardt, Charles E.

    1985-01-01

    The standard addition titration is a precise and rapid method for the determination of the acidity in rain or snow samples. The method requires use of a standard buret, a pH meter, and Gran's plot to determine the equivalence point. Experimental procedures used and typical results obtained are presented. (JN)

  16. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF HUMAN HAIR (UA-F-26.0)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship human hair for analysis of mercury. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed to ensure consistent data ...

  17. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR ARCHIVE PROCEDURE FOR STUDY SAMPLES (UA-G-4.0)

    EPA Science Inventory

    The purpose of this SOP is to outline the archive/custody guidelines used by the Arizona Border Study. This procedure was followed to maintain and locate samples, extracts, tracings and hard copy results after laboratory analysis during the Arizona NHEXAS project and the Border ...

  18. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR RECEIPT OF EQUIPMENT AND FIELD IMPLEMENTATION SUPPLIES (UA-G-5.0)

    EPA Science Inventory

    The purpose of this SOP is to outline procedures for the receipt of equipment and field implementation supplies for the Arizona Border Study. This procedure was followed to ensure consistent data custody, storage, transfer, and analysis of a high quality during the Arizona NHEXA...

  19. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF UNKNOWN SUBSTANCES (UA-F-25.0)

    EPA Science Inventory

    The purpose of this SOP is to describe how to collect, store, and ship unknown substances for chemical analysis and identification. This SOP provides a brief description of the sample containers, collection, storage, shipping and custody procedures. This procedure was followed ...

  20. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF PESTICIDES FROM DERMAL WIPE SAMPLES (BCO-L-12.1)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the "Border" study. Keywords: dermal wipe;...

  1. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF SURFACE WIPE SAMPLES FOR PESTICIDES OR METALS (UA-F-8.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting surface wipe samples inside a home for analysis of either metals or pesticides. This procedure covers the preparation of the surface wipe material and field activities. This protocol was followed to ensure con...

  2. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CLEANING GLASSWARE TO BE USED FOR INORGANIC METALS ANALYSIS (BCO-L-10.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...

  3. Funding analysis of bilateral autologous free-flap breast reconstructions in Australia.

    PubMed

    Sinha, Shiba; Ruskin, Olivia; McCombe, David; Morrison, Wayne; Webb, Angela

    2015-08-01

    Bilateral breast reconstructions are being increasingly performed. Autologous free-flap reconstructions represent the gold standard for post-mastectomy breast reconstruction but are resource intensive. This study aims to investigate the difference between hospital reimbursement and true cost of bilateral autologous free-flap reconstructions. Retrospective analysis of patients who underwent bilateral autologous free-flap reconstructions at a single Australian tertiary referral centre was performed. Hospital reimbursement was determined from coding analysis. A true cost analysis was also performed. Comparisons were made considering the effect of timing, indication and complications of the procedure. Forty-six bilateral autologous free-flap procedures were performed (87 deep inferior epigastric perforators (DIEPs), four superficial inferior epigastric artery perforator flaps (SIEAs) and one muscle-sparing free transverse rectus abdominis myocutaneous flap (MS-TRAM)). The mean funding discrepancy between hospital reimbursement and actual cost was $12,137 ± $8539 (mean ± standard deviation (SD)) (n = 46). Twenty-four per cent (n = 11) of the cases had been coded inaccurately. If these cases were excluded from analysis, the mean funding discrepancy per case was $9168 ± $7453 (n = 35). Minor and major complications significantly increased the true cost and funding discrepancy (p = 0.02). Bilateral free-flap breast reconstructions performed in Australian public hospitals result in a funding discrepancy. Failure to be economically viable threatens the provision of this procedure in the public system. Plastic surgeons and hospital managers need to adopt measures in order to make these gold-standard procedures cost neutral. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Development of QC Procedures for Ocean Data Obtained by National Research Projects of Korea

    NASA Astrophysics Data System (ADS)

    Kim, S. D.; Park, H. M.

    2017-12-01

    To establish data management system for ocean data obtained by national research projects of Ministry of Oceans and Fisheries of Korea, KIOST conducted standardization and development of QC procedures. After reviewing and analyzing the existing international and domestic ocean-data standards and QC procedures, the draft version of standards and QC procedures were prepared. The proposed standards and QC procedures were reviewed and revised by experts in the field of oceanography and academic societies several times. A technical report on the standards of 25 data items and 12 QC procedures for physical, chemical, biological and geological data items. The QC procedure for temperature and salinity data was set up by referring the manuals published by GTSPP, ARGO and IOOS QARTOD. It consists of 16 QC tests applicable for vertical profile data and time series data obtained in real-time mode and delay mode. Three regional range tests to inspect annual, seasonal and monthly variations were included in the procedure. Three programs were developed to calculate and provide upper limit and lower limit of temperature and salinity at depth from 0 to 1550m. TS data of World Ocean Database, ARGO, GTSPP and in-house data of KIOST were analysed statistically to calculate regional limit of Northwest Pacific area. Based on statistical analysis, the programs calculate regional ranges using mean and standard deviation at 3 kind of grid systems (3° grid, 1° grid and 0.5° grid) and provide recommendation. The QC procedures for 12 data items were set up during 1st phase of national program for data management (2012-2015) and are being applied to national research projects practically at 2nd phase (2016-2019). The QC procedures will be revised by reviewing the result of QC application when the 2nd phase of data management programs is completed.

  5. The computational structural mechanics testbed procedures manual

    NASA Technical Reports Server (NTRS)

    Stewart, Caroline B. (Compiler)

    1991-01-01

    The purpose of this manual is to document the standard high level command language procedures of the Computational Structural Mechanics (CSM) Testbed software system. A description of each procedure including its function, commands, data interface, and use is presented. This manual is designed to assist users in defining and using command procedures to perform structural analysis in the CSM Testbed User's Manual and the CSM Testbed Data Library Description.

  6. [From Science to Law: Findings of Reha XI Project on Ascertaining the Need for Rehabilitation in Medical Service Assessments].

    PubMed

    Kalwitzki, T; Huter, K; Runte, R; Breuninger, K; Janatzek, S; Gronemeyer, S; Gansweid, B; Rothgang, H

    2017-03-01

    Introduction: In the broad-based consortium project "Reha XI - Identifying rehabilitative requirements in medical service assessments: evaluation and implementation", a comprehensive analysis of the corresponding procedures was carried out by the medical services of the German Health Insurance Funds (MDK). On the basis of this analysis, a Good Practice Standard (GPS) for assessments was drawn up and scientifically evaluated. This article discusses the findings and applicability of the GPS as the basis for a nationwide standardized procedure in Germany as required by the Second Act to Strengthen Long-Term Care (PSG II) under Vol. XI Para. 18 (6) of the German Social Welfare Code. Method: The consortium project comprised four project phases: 1. Qualitative and quantitative situation analysis of the procedures for ascertaining rehabilitative needs in care assessments carried out by the MDK; 2. Development of a Good Practice Standard (GPS) in a structured, consensus-based procedure; 3. Scientific evaluation of the validity, reliability and practicability of the assessment procedure according to the GPS in the MDK's operational practice; 4. Survey of long-term care insurance funds with respect to the appropriateness of the rehabilitation recommendations drawn up by care assessors in line with the GPS for providing a qualified recommendation for the applicant. The evaluation carried out in the third project phase was subject to methodological limitations that may have given rise to distortions in the findings. Findings: On the basis of the situation analysis, 7 major thematic areas were identified in which improvements were implemented by applying the GPS. For the evaluation of the GPS, a total of 3 247 applicants were assessed in line with the GPS; in 6.3% of the applicants, an indication for medical rehabilitation was determined. The GPS procedure showed a high degree of reliability and practicability, but the values for the validity of the assessment procedure were highly unsatisfactory. The degree of acceptance by the long-term care insurance funds with respect to the recommendations for rehabilitation following the GPS procedure was high. Conclusion: The application of a general standard across all MDKs shows marked improvements in the quality of the assessment procedure and leads more frequently to the ascertainment of an indication for medical rehabilitation. The methodological problems and the unsatisfactory findings with respect to the validity of the assessors' decisions require further scientific scrutiny. © Georg Thieme Verlag KG Stuttgart · New York.

  7. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING SOLID FOOD SAMPLES FOR ANALYSIS OF PERSISTENT ORGANIC POLLUTANTS (SOP-5.20)

    EPA Science Inventory

    This SOP describes the procedures for homogenizing, extracting and concentrating solid food samples for persistent organic pollutants such as organochlorine compounds, organophosphate compounds, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, substituted phenols, and...

  8. NHEXAS PHASE I ARIZONA STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the NHEXAS Phase I Arizona study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assurance, (...

  9. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  10. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  11. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  12. 40 CFR 610.10 - Program purpose.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... DEVICES Test Procedures and Evaluation Criteria General Provisions § 610.10 Program purpose. (a) The... standardized procedures, the performance of various retrofit devices applicable to automobiles for which fuel... statistical analysis of data from vehicle tests, the evaluation program will determine the effects on fuel...

  13. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING LIQUID FOOD SAMPLES FOR ANALYSIS OF PERSISTENT ORGANIC POLLUTANTS (SOP-5.19)

    EPA Science Inventory

    This SOP describes the procedures for homogenizing, extracting, and concentrating liquid food samples for neutral persistent organic pollutants such as organochlorine compounds, organophosphate compounds, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and phenols.

  14. Analysis of students' assessments in middle school curriculum materials: Aiming precisely at benchmarks and standards

    NASA Astrophysics Data System (ADS)

    Stern, Luli

    2002-11-01

    Assessment influences every level of the education system and is one of the most crucial catalysts for reform in science curriculum and instruction. Teachers, administrators, and others who choose, assemble, or develop assessments face the difficulty of judging whether tasks are truly aligned with national or state standards and whether they are effective in revealing what students actually know. Project 2061 of the American Association for the Advancement of Science has developed and field-tested a procedure for analyzing curriculum materials, including their assessments, in terms of how well they are likely to contribute to the attainment of benchmarks and standards. With respect to assessment in curriculum materials, this procedure evaluates whether this assessment has the potential to reveal whether students have attained specific ideas in benchmarks and standards and whether information gained from students' responses can be used to inform subsequent instruction. Using this procedure, Project 2061 had produced a database of analytical reports on nine widely used science middle school curriculum materials. The analysis of assessments included in these materials shows that whereas currently available materials devote significant sections in their instruction to ideas included in national standards documents, students are typically not assessed on these ideas. The analysis results described in the report point to strengths and limitations of these widely used assessments and identify a range of good and poor assessment tasks that can shed light on important characteristics of good assessment.

  15. 24 CFR 200.942 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the following standards: (i) AATCC 20A-81—Fiber Analysis: Quantitative; (ii) AATCC 16E-82... 12215, Research Triangle Park, NC 27709; (ii) American Society for Testing and Materials (ASTM), 1916...

  16. 24 CFR 200.942 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the following standards: (i) AATCC 20A-81—Fiber Analysis: Quantitative; (ii) AATCC 16E-82... 12215, Research Triangle Park, NC 27709; (ii) American Society for Testing and Materials (ASTM), 1916...

  17. 24 CFR 200.942 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the following standards: (i) AATCC 20A-81—Fiber Analysis: Quantitative; (ii) AATCC 16E-82... 12215, Research Triangle Park, NC 27709; (ii) American Society for Testing and Materials (ASTM), 1916...

  18. 24 CFR 200.942 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the following standards: (i) AATCC 20A-81—Fiber Analysis: Quantitative; (ii) AATCC 16E-82... 12215, Research Triangle Park, NC 27709; (ii) American Society for Testing and Materials (ASTM), 1916...

  19. 24 CFR 200.942 - Supplementary specific procedural requirements under HUD building product standards and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the following standards: (i) AATCC 20A-81—Fiber Analysis: Quantitative; (ii) AATCC 16E-82... 12215, Research Triangle Park, NC 27709; (ii) American Society for Testing and Materials (ASTM), 1916...

  20. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METAL, PESTICIDE, AND CREATININE ANALYSIS (F10)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collection, storage, and shipment of urine samples for metal, pesticides, and creatinine analysis. Samples were collected on Days 2 and 8 of each Cycle. The Day 2 sample was analyzed for metals and creatinine. The Day 8...

  1. Fort Dix Remedial Investigation/Feasibility Study for MAG-1 Area

    DTIC Science & Technology

    1994-01-01

    by PID headspace results or odor ), samples should be diluted to bring the target compound concentrations within the instrument calibration range...Conductivity Testing ................... 2-38 2.9 ANALYTICAL PROCEDURES FOR FIELD SCREENING SAMPLES .. 2-38 2.9.1 Volatile Organic Compounds ...ANALYSIS OF VOLATILE ORGANIC COMPOUNDS BY FIELD GAS CHROMATOGRAPHY - STANDARD OPERATING PROCEDURE APPENDIX B RDX EXPLOSIVES FIELD TEST KIT PROCEDURES

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF PESTICIDES FROM DERMAL WIPE SAMPLES (BCO-L-12.1)

    EPA Science Inventory

    The purpose of this SOP is to describe procedures for extracting and preparing a dermal wipe sample for GC/MS analysis of pesticides. This procedure was followed to ensure consistent data retrieval during the Arizona NHEXAS project and the Border study. Keywords: dermal wipe; p...

  3. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF URINE SAMPLES FOR METALS AND PESTICIDES ANALYSIS (UA-F-20.1)

    EPA Science Inventory

    The purpose of this SOP is to guide the collection, storage, and shipment of urine samples collected. This SOP provides a brief description of sample, collection, preservation, storage, shipping, and custody procedures. This procedure was followed to ensure consistent data retri...

  4. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR FOOD SAMPLE COMPARISON WITH DIARY AND SHIPMENT (UA-L-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped for further analysis. This procedure applies to the checking of food samples and shipment ...

  5. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR CLEANING GLASSWARE TO BE USED FOR INORGANIC METALS ANALYSIS (BCO-L-10.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR FOOD SAMPLE COMPARISON WITH DIARY AND SHIPMENT (UA-L-13.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for checking the food collections with the food stated as consumed in the 24-Hour Food Diary. The sample is then packaged and shipped to the FDA for further analysis. This procedure applies to the checking of food samples an...

  7. 40 CFR 1065.12 - Approval of alternate procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... engine meets all applicable emission standards according to specified procedures. (iii) Use statistical.... (e) We may give you specific directions regarding methods for statistical analysis, or we may approve... statistical tests. Perform the tests as follows: (1) Repeat measurements for all applicable duty cycles at...

  8. MASW on the standard seismic prospective scale using full spread recording

    NASA Astrophysics Data System (ADS)

    Białas, Sebastian; Majdański, Mariusz; Trzeciak, Maciej; Gałczyński, Edward; Maksym, Andrzej

    2015-04-01

    The Multichannel Analysis of Surface Waves (MASW) is one of seismic survey methods that use the dispersion curve of surface waves in order to describe the stiffness of the surface. Is is used mainly for geotechnical engineering scale with total length of spread between 5 - 450 m and spread offset between 1 - 100 m, the hummer is the seismic source on this surveys. The standard procedure of MASW survey is: data acquisition, dispersion analysis and inversion of extracting dispersion curve to obtain the closest theoretical curve. The final result includes share-wave velocity (Vs) values at different depth along the surveyed lines. The main goal of this work is to expand this engineering method to the bigger scale with the length of standard prospecting spread of 20 km using 4.5 Hz version of vertical component geophones. The standard vibroseis and explosive method are used as the seismic source. The acquisition were conducted on the full spread all the time during each single shoot. The seismic data acquisition used for this analysis were carried out on the Braniewo 2014 project in north of Poland. The results achieved during standard MASW procedure says that this method can be used on much bigger scale as well. The different methodology of this analysis requires only much stronger seismic source.

  9. Laboratory and quality assurance protocols for the analysis of herbicides in ground water from the Management Systems Evaluation Area, Princeton, Minnesota

    USGS Publications Warehouse

    Larson, S.J.; Capel, P.D.; VanderLoop, A.G.

    1996-01-01

    Laboratory and quality assurance procedures for the analysis of ground-water samples for herbicides at the Management Systems Evaluation Area near Princeton, Minnesota are described. The target herbicides include atrazine, de-ethylatrazine, de-isopropylatrazine, metribuzin, alachlor, 2,6-diethylaniline, and metolachlor. The analytical techniques used are solid-phase extraction, and analysis by gas chromatography with mass-selective detection. Descriptions of cleaning procedures, preparation of standard solutions, isolation of analytes from water, sample transfer methods, instrumental analysis, and data analysis are included.

  10. Standardized Analytical Methods for Environmental Restoration Following Homeland Security Events

    USDA-ARS?s Scientific Manuscript database

    Methodology was formulated for use in the event of a terrorist attack using a variety of chemical, radioactive, biological, and toxic agents. Standardized analysis procedures were determined for use should these events occur. This publication is annually updated....

  11. FINANCIAL ANALYSIS OF CURRENT OPERATIONS OF COLLEGES AND UNIVERSITIES.

    ERIC Educational Resources Information Center

    SWANSON, JOHN E.; AND OTHERS

    TECHNIQUES FOR DEVELOPING FINANCIAL AND RELATED COST-EFFECTIVENESS DATA FOR PUBLIC AND PRIVATELY SUPPORTED AMERICAN COLLEGES AND UNIVERSITIES WERE STUDIED TO FORMULATE PRINCIPLES, PROCEDURES, AND STANDARDS FOR THE ACCUMULATION AND ANALYSES OF CURRENT OPERATING COSTS. AFTER SEPARATE ANALYSES OF INSTITUTIONAL PROCEDURES AND REPORTS, ANALYTIC UNITS…

  12. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--LIST OF STANDARD OPERATING PROCEDURES

    EPA Science Inventory

    This document lists available protocols and SOPs for the U.S.-Mexico Border Program study. It identifies protocols and SOPs for the following study components: (1) Sample collection and field operations, (2) Sample analysis, (3) General laboratory procedures, (4) Quality Assuranc...

  13. PACM: A Two-Stage Procedure for Analyzing Structural Models.

    ERIC Educational Resources Information Center

    Lehmann, Donald R.; Gupta, Sunil

    1989-01-01

    Path Analysis of Covariance Matrix (PACM) is described as a way to separately estimate measurement and structural models using standard least squares procedures. PACM was empirically compared to simultaneous maximum likelihood estimation and use of the LISREL computer program, and its advantages are identified. (SLD)

  14. 40 CFR 63.2382 - What notifications must I submit and when and what information should be submitted?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sampling and analysis procedures and quality assurance procedures. (iii) Descriptions of monitoring devices... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS... compliance assessments, inspections and repairs, and calculations used to demonstrate initial compliance...

  15. Procedures for determination of detection limits: application to high-performance liquid chromatography analysis of fat-soluble vitamins in human serum.

    PubMed

    Browne, Richard W; Whitcomb, Brian W

    2010-07-01

    Problems in the analysis of laboratory data commonly arise in epidemiologic studies in which biomarkers subject to lower detection thresholds are used. Various thresholds exist including limit of detection (LOD), limit of quantification (LOQ), and limit of blank (LOB). Choosing appropriate strategies for dealing with data affected by such limits relies on proper understanding of the nature of the detection limit and its determination. In this paper, we demonstrate experimental and statistical procedures generally used for estimating different detection limits according to standard procedures in the context of analysis of fat-soluble vitamins and micronutrients in human serum. Fat-soluble vitamins and micronutrients were analyzed by high-performance liquid chromatography with diode array detection. A simulated serum matrix blank was repeatedly analyzed for determination of LOB parametrically by using the observed blank distribution as well as nonparametrically by using ranks. The LOD was determined by combining information regarding the LOB with data from repeated analysis of standard reference materials (SRMs), diluted to low levels; from LOB to 2-3 times LOB. The LOQ was determined experimentally by plotting the observed relative standard deviation (RSD) of SRM replicates compared with the concentration, where the LOQ is the concentration at an RSD of 20%. Experimental approaches and example statistical procedures are given for determination of LOB, LOD, and LOQ. These quantities are reported for each measured analyte. For many analyses, there is considerable information available below the LOQ. Epidemiologic studies must understand the nature of these detection limits and how they have been estimated for appropriate treatment of affected data.

  16. Consequences of Decontamination Procedures in Forensic Hair Analysis Using Metal-Assisted Secondary Ion Mass Spectrometry Analysis.

    PubMed

    Cuypers, Eva; Flinders, Bryn; Boone, Carolien M; Bosman, Ingrid J; Lusthof, Klaas J; Van Asten, Arian C; Tytgat, Jan; Heeren, Ron M A

    2016-03-15

    Today, hair testing is considered to be the standard method for the detection of chronic drug abuse. Nevertheless, the differentiation between systemic exposure and external contamination remains a major challenge in the forensic interpretation of hair analysis. Nowadays, it is still impossible to directly show the difference between external contamination and use-related incorporation. Although the effects of washing procedures on the distribution of (incorporated) drugs in hair remain unknown, these decontamination procedures prior to hair analysis are considered to be indispensable in order to exclude external contamination. However, insights into the effect of decontamination protocols on levels and distribution of drugs incorporated in hair are essential to draw the correct forensic conclusions from hair analysis; we studied the consequences of these procedures on the spatial distribution of cocaine in hair using imaging mass spectrometry. Additionally, using metal-assisted secondary ion mass spectrometry, we are the first to directly show the difference between cocaine-contaminated and user hair without any prior washing procedure.

  17. Photovoltaic Calibrations at the National Renewable Energy Laboratory and Uncertainty Analysis Following the ISO 17025 Guidelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emery, Keith

    The measurement of photovoltaic (PV) performance with respect to reference conditions requires measuring current versus voltage for a given tabular reference spectrum, junction temperature, and total irradiance. This report presents the procedures implemented by the PV Cell and Module Performance Characterization Group at the National Renewable Energy Laboratory (NREL) to achieve the lowest practical uncertainty. A rigorous uncertainty analysis of these procedures is presented, which follows the International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement. This uncertainty analysis is required for the team’s laboratory accreditation under ISO standard 17025, “General Requirements for the Competence ofmore » Testing and Calibration Laboratories.” The report also discusses additional areas where the uncertainty can be reduced.« less

  18. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF DERMAL WIPE SAMPLES FOR PESTICIDES AND METALS ANALYSIS (UA-F-9.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedures for collecting a dermal wipe sample from a participant's hands for the measurement of pesticide or metal residues on the skin. This procedure covers the preparation of the dermal wipe material and field activities. This prot...

  19. Costing the satellite power system

    NASA Technical Reports Server (NTRS)

    Hazelrigg, G. A., Jr.

    1978-01-01

    The paper presents a methodology for satellite power system costing, places approximate limits on the accuracy possible in cost estimates made at this time, and outlines the use of probabilistic cost information in support of the decision-making process. Reasons for using probabilistic costing or risk analysis procedures instead of standard deterministic costing procedures are considered. Components of cost, costing estimating relationships, grass roots costing, and risk analysis are discussed. Risk analysis using a Monte Carlo simulation model is used to estimate future costs.

  20. Physical and cognitive task analysis in interventional radiology.

    PubMed

    Johnson, S; Healey, A; Evans, J; Murphy, M; Crawshaw, M; Gould, D

    2006-01-01

    To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  1. Equilibrium paths analysis of materials with rheological properties by using the chaos theory

    NASA Astrophysics Data System (ADS)

    Bednarek, Paweł; Rządkowski, Jan

    2018-01-01

    The numerical equilibrium path analysis of the material with random rheological properties by using standard procedures and specialist computer programs was not successful. The proper solution for the analysed heuristic model of the material was obtained on the base of chaos theory elements and neural networks. The paper deals with mathematical reasons of used computer programs and also are elaborated the properties of the attractor used in analysis. There are presented results of conducted numerical analysis both in a numerical and in graphical form for the used procedures.

  2. Medical Office Laboratory Procedures: Course Proposal. Revised.

    ERIC Educational Resources Information Center

    Baker, Eleanor

    A proposal is presented for a Community College of Philadelphia course, entitled "Medical Office Laboratory Procedures," which provides a laboratory introduction to microscopic and chemical analysis of blood and urine as performed in the physician's office. Following a standard cover form, a statement of the purpose of the course discusses course…

  3. 48 CFR 1552.211-79 - Compliance with EPA policies for information resources management.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... procedures set forth on the Office of Environmental Information policy Web site. Upon receipt of a work... majority of the Agency's IRM policies, standards, and procedures. (c) Section 508 requirements... by EPA or contractors operating EPA programs. (2) The analysis of requirements for, study of the...

  4. 48 CFR 1552.211-79 - Compliance with EPA policies for information resources management.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... procedures set forth on the Office of Environmental Information policy Web site. Upon receipt of a work... majority of the Agency's IRM policies, standards, and procedures. (c) Section 508 requirements... by EPA or contractors operating EPA programs. (2) The analysis of requirements for, study of the...

  5. An analysis of ratings: A guide to RMRATE

    Treesearch

    Thomas C. Brown; Terry C. Daniel; Herbert W. Schroeder; Glen E. Brink

    1990-01-01

    This report describes RMRATE, a computer program for analyzing rating judgments. RMRATE scales ratings using several scaling procedures, and compares the resulting scale values. The scaling procedures include the median and simple mean, standardized values, scale values based on Thurstone's Law of Categorical Judgment, and regression-based values. RMRATE also...

  6. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CUSTODY OF FIELD SAMPLES (UA-C-1.0)

    EPA Science Inventory

    The purpose of this SOP is to outline sample custody guidelines used by the NHEXAS Arizona research project. This procedure was followed to maintain sample integrity and ensure consistent data retrieval, transport, storage, shipment, and analysis during the Arizona NHEXAS projec...

  7. Standardizing bimanual vaginal examination using cognitive task analysis.

    PubMed

    Plumptre, Isabella; Mulki, Omar; Granados, Alejandro; Gayle, Claudine; Ahmed, Shahla; Low-Beer, Naomi; Higham, Jenny; Bello, Fernando

    2017-10-01

    To create a standardized universal list of procedural steps for bimanual vaginal examination (BVE) for teaching, assessment, and simulator development. This observational study, conducted from June-July 2012 and July-December 2014, collected video data of 10 expert clinicians performing BVE in a nonclinical environment. Video data were analyzed to produce a cognitive task analysis (CTA) of the examination steps performed. The CTA was further refined through structured interviews to make it suitable for teaching or assessment. It was validated through its use as a procedural examination checklist to rate expert clinician performance. BVE was deconstructed into 88 detailed steps outlining the complete examination process. These initial 88 steps were reduced to 35 by focusing on the unseen internal examination, then further refined through interviews with five experts into 30 essential procedural steps, five of which are additional steps if pathology is suspected. Using the CTA as a procedural checklist, the mean number of steps performed and/or verbalized was 21.6 ± 3.12 (72% ± 10.4%; range, 15.9-27.9, 53%-93%). This approach identified 30 essential steps for performing BVE, producing a new technique and standardized tool for teaching, assessment, and simulator development. © 2017 International Federation of Gynecology and Obstetrics.

  8. A dc model for power switching transistors suitable for computer-aided design and analysis

    NASA Technical Reports Server (NTRS)

    Wilson, P. M.; George, R. T., Jr.; Owen, H. A.; Wilson, T. G.

    1979-01-01

    A model for bipolar junction power switching transistors whose parameters can be readily obtained by the circuit design engineer, and which can be conveniently incorporated into standard computer-based circuit analysis programs is presented. This formulation results from measurements which may be made with standard laboratory equipment. Measurement procedures, as well as a comparison between actual and computed results, are presented.

  9. Development of a viability standard curve for microencapsulated probiotic bacteria using confocal microscopy and image analysis software.

    PubMed

    Moore, Sarah; Kailasapathy, Kasipathy; Phillips, Michael; Jones, Mark R

    2015-07-01

    Microencapsulation is proposed to protect probiotic strains from food processing procedures and to maintain probiotic viability. Little research has described the in situ viability of microencapsulated probiotics. This study successfully developed a real-time viability standard curve for microencapsulated bacteria using confocal microscopy, fluorescent dyes and image analysis software. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. The DACUM Job Analysis Process.

    ERIC Educational Resources Information Center

    Dofasco, Inc., Hamilton (Ontario).

    This document explains the DACUM (Developing A Curriculum) process for analyzing task-based jobs to: identify where standard operating procedures are required; identify duplicated low value added tasks; develop performance standards; create job descriptions; and identify the elements that must be included in job-specific training programs. The…

  11. A Network Analysis of Concept Maps of Triangle Concepts

    ERIC Educational Resources Information Center

    Haiyue, Jin; Khoon Yoong, Wong

    2010-01-01

    Mathematics educators and mathematics standards of curriculum have emphasised the importance of constructing the interconnectedness among mathematic concepts ("conceptual understanding") instead of only the ability to carry out standard procedures in an isolated fashion. Researchers have attempted to assess the knowledge networks in…

  12. Pros and Cons of 3D Image Fusion in Endovascular Aortic Repair: A Systematic Review and Meta-analysis.

    PubMed

    Goudeketting, Seline R; Heinen, Stefan G H; Ünlü, Çağdaş; van den Heuvel, Daniel A F; de Vries, Jean-Paul P M; van Strijen, Marco J; Sailer, Anna M

    2017-08-01

    To systematically review and meta-analyze the added value of 3-dimensional (3D) image fusion technology in endovascular aortic repair for its potential to reduce contrast media volume, radiation dose, procedure time, and fluoroscopy time. Electronic databases were systematically searched for studies published between January 2010 and March 2016 that included a control group describing 3D fusion imaging in endovascular aortic procedures. Two independent reviewers assessed the methodological quality of the included studies and extracted data on iodinated contrast volume, radiation dose, procedure time, and fluoroscopy time. The contrast use for standard and complex endovascular aortic repairs (fenestrated, branched, and chimney) were pooled using a random-effects model; outcomes are reported as the mean difference with 95% confidence intervals (CIs). Seven studies, 5 retrospective and 2 prospective, involving 921 patients were selected for analysis. The methodological quality of the studies was moderate (median 17, range 15-18). The use of fusion imaging led to an estimated mean reduction in iodinated contrast of 40.1 mL (95% CI 16.4 to 63.7, p=0.002) for standard procedures and a mean 70.7 mL (95% CI 44.8 to 96.6, p<0.001) for complex repairs. Secondary outcome measures were not pooled because of potential bias in nonrandomized data, but radiation doses, procedure times, and fluoroscopy times were lower, although not always significantly, in the fusion group in 6 of the 7 studies. Compared with the control group, 3D fusion imaging is associated with a significant reduction in the volume of contrast employed for standard and complex endovascular aortic procedures, which can be particularly important in patients with renal failure. Radiation doses, procedure times, and fluoroscopy times were reduced when 3D fusion was used.

  13. Colling Wipe Samples for VX Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koester, C; Hoppes, W G

    2010-02-11

    This standard operating procedure (SOP) provides uniform procedures for the collection of wipe samples of VX residues from surfaces. Personnel may use this procedure to collect and handle wipe samples in the field. Various surfaces, including building materials (wood, metal, tile, vinyl, etc.) and equipment, may be sampled based on this procedure. The purpose of such sampling is to determine whether or not the relevant surfaces are contaminated, to determine the extent of their contamination, to evaluate the effectiveness of decontamination procedures, and to determine the amount of contaminant that might present as a contact hazard.

  14. 33 CFR 154.2020 - Certification and recertification-owner/operator responsibilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Procedures,” and in Military Standard MIL-STD-882B for a quantitative failure analysis. For assistance in... quantitative failure analysis is also conducted, the level of safety attained is at least one order of...

  15. Evaluation of the Utility of a Discrete-Trial Functional Analysis in Early Intervention Classrooms

    ERIC Educational Resources Information Center

    Kodak, Tiffany; Fisher, Wayne W.; Paden, Amber; Dickes, Nitasha

    2013-01-01

    We evaluated a discrete-trial functional analysis implemented by regular classroom staff in a classroom setting. The results suggest that the discrete-trial functional analysis identified a social function for each participant and may require fewer staff than standard functional analysis procedures.

  16. Shuttle remote manipulator system mission preparation and operations

    NASA Technical Reports Server (NTRS)

    Smith, Ernest E., Jr.

    1989-01-01

    The preflight planning, analysis, procedures development, and operations support for the Space Transportation System payload deployment and retrieval missions utilizing the Shuttle Remote Manipulator System are summarized. Analysis of the normal operational loads and failure induced loads and motion are factored into all procedures. Both the astronaut flight crews and the Mission Control Center flight control teams receive considerable training for standard and mission specific operations. The real time flight control team activities are described.

  17. Comparison of procedures for correction of matrix interferences in the analysis of soils by ICP-OES with CCD detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sadler, D.A.; Sun, F.; Littlejohn, D.

    1995-12-31

    ICP-OES is a useful technique for multi-element analysis of soils. However, as a number of elements are present in relatively high concentrations, matrix interferences can occur and examples have been widely reported. The availability of CCD detectors has increased the opportunities for rapid multi-element, multi-wave-length determination of elemental concentrations in soils and other environmental samples. As the composition of soils from industrial sites can vary considerably, especially when taken from different pit horizons, procedures are required to assess the extent of interferences and correct the effects, on a simultaneous multi-element basis. In single element analysis, plasma operating conditions can sometimesmore » be varied to minimize or even remove multiplicative interferences. In simultaneous multi-element analysis, the scope for this approach may be limited, depending on the spectrochemical characteristics of the emitting analyte species. Matrix matching, by addition of major sample components to the analyte calibrant solutions, can be used to minimize inaccuracies. However, there are also limitations to this procedure, when the sample composition varies significantly. Multiplicative interference effects can also be assessed by a {open_quotes}single standard addition{close_quotes} of each analyte to the sample solution and the information obtained may be used to correct the analyte concentrations determined directly. Each of these approaches has been evaluated to ascertain the best procedure for multi-element analysis of industrial soils by ICP-OES with CCD detection at multiple wavelengths. Standard reference materials and field samples have been analyzed to illustrate the efficacy of each procedure.« less

  18. MATLAB-implemented estimation procedure for model-based assessment of hepatic insulin degradation from standard intravenous glucose tolerance test data.

    PubMed

    Di Nardo, Francesco; Mengoni, Michele; Morettini, Micaela

    2013-05-01

    Present study provides a novel MATLAB-based parameter estimation procedure for individual assessment of hepatic insulin degradation (HID) process from standard frequently-sampled intravenous glucose tolerance test (FSIGTT) data. Direct access to the source code, offered by MATLAB, enabled us to design an optimization procedure based on the alternating use of Gauss-Newton's and Levenberg-Marquardt's algorithms, which assures the full convergence of the process and the containment of computational time. Reliability was tested by direct comparison with the application, in eighteen non-diabetic subjects, of well-known kinetic analysis software package SAAM II, and by application on different data. Agreement between MATLAB and SAAM II was warranted by intraclass correlation coefficients ≥0.73; no significant differences between corresponding mean parameter estimates and prediction of HID rate; and consistent residual analysis. Moreover, MATLAB optimization procedure resulted in a significant 51% reduction of CV% for the worst-estimated parameter by SAAM II and in maintaining all model-parameter CV% <20%. In conclusion, our MATLAB-based procedure was suggested as a suitable tool for the individual assessment of HID process. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-10-15

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.

  20. Blood gas testing and related measurements: National recommendations on behalf of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana

    2016-01-01

    Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301

  1. Obtaining accreditation by the pharmacy compounding accreditation board, part 2: developing essential standard operating procedures.

    PubMed

    Cabaleiro, Joe

    2007-01-01

    A key component of qualifying for accreditation with the Pharmacy Compounding Accreditation Board is having a set of comprehensive standard operating procedures that are being used by the pharmacy staff. The three criteria in standard operating procedures for which the Pharmacy Compounding Accreditation Board looks are: (1)written standard operating procedures; (2)standard operating procedures that reflect what the organization actualy does; and (3) whether the written standard operating procedures are implemented. Following specified steps in the preparation of standard operating procedures will result in procedures that meet Pharmacy Compounding Accreditation Board Requirements, thereby placing pharmacies one step closer to qualifying for accreditation.

  2. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR CUSTODY OF FIELD SAMPLES (UA-C-1.0)

    EPA Science Inventory

    The purpose of this SOP is to outline sample custody guidelines used by the Arizona Border Study. This procedure was followed to maintain sample integrity and ensure consistent data retrieval, transport, storage, shipment, and analysis during the Arizona NHEXAS project and the B...

  3. 48 CFR 1552.211-79 - Compliance with EPA policies for information resources management.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... procedures set forth on the Office of Environmental Information policy Web site. Upon receipt of a work... majority of the Agency's IRM policies, standards, and procedures. (c) Section 508 requirements. Contract... by EPA or contractors operating EPA programs. (2) The analysis of requirements for, study of the...

  4. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ISOLATION OF MALFUNCTIONING OR DAMAGED EQUIPMENT (UA-G-2.0)

    EPA Science Inventory

    The purpose of this SOP is to identify and isolate malfunctioning or damaged equipment for the NHEXAS Arizona research project. This procedure was followed to ensure consistent data custody, storage, transfer and analysis of a high quality during the Arizona NHEXAS project and t...

  5. [Criterion of dental treatment for the disabled].

    PubMed

    Huchun, Wan; Zheng, Yang; Hongkun, Wu; Jianguo, Liu; Jin, Zhao; Xiaoping, Ji; Lin, Zhu; Deqin, Yang; Xuedong, Zhou

    2017-08-01

    The number of disabled persons increases in the course of human life and in the aging population. The high prevalence, low treatment rate, long therapy period, and sophisticated procedures prevent most of disabled individuals from availing dental services. Moreover, special dental institutions for the disabled are insufficient, and a certain treatment standard is commonly not complied. This study performed analysis and evaluation, including treatment features, pretreatment procedures, patient communication, treatment factors, and treatment standards to provide a targeted solution for the special requirements of the oral therapy for disabled patients.

  6. Simulations of motor unit number estimation techniques

    NASA Astrophysics Data System (ADS)

    Major, Lora A.; Jones, Kelvin E.

    2005-06-01

    Motor unit number estimation (MUNE) is an electrodiagnostic procedure used to evaluate the number of motor axons connected to a muscle. All MUNE techniques rely on assumptions that must be fulfilled to produce a valid estimate. As there is no gold standard to compare the MUNE techniques against, we have developed a model of the relevant neuromuscular physiology and have used this model to simulate various MUNE techniques. The model allows for a quantitative analysis of candidate MUNE techniques that will hopefully contribute to consensus regarding a standard procedure for performing MUNE.

  7. iPSC-Derived MSCs that Are Genetically Engineered for Systemic Bone Augmentation

    DTIC Science & Technology

    2013-08-01

    cloned into a pJET1.2 vector (Fermentas, Glen Burnie, MD) and sequenced by MCLAB (San Francisco, CA). Karyotyping and G-banding. GTG -banding chromosome...publication [25]. Karyotyping and G-banding Giemsa ( GTG )-banding chromosome analysis was carried out in the LLU Radiation Research Laboratories. Standard...banding GTG -banding chromosome analysis was carried out in the LLU Radiation Research Laboratories. Standard DNA spectral karyo- typing procedures

  8. Details of the 1998 Watt Balance Experiment Determining the Planck Constant

    PubMed Central

    Steiner, Richard; Newell, David; Williams, Edwin

    2005-01-01

    The National Institute of Standards and Technology (NIST) watt balance experiment completed a determination of Planck constant in 1998 with a relative standard uncertainty of 87 × 10−9 (k = 1), concurrently with an upper limit on the drift rate of the SI kilogram mass standard. A number of other fundamental physical constants with uncertainties dominated by this result are also calculated. This paper focuses on the details of the balance apparatus, the measurement and control procedures, and the reference calibrations. The alignment procedures are also described, as is a novel mutual inductance measurement procedure. The analysis summary discusses the data noise sources and estimates for the Type B uncertainty contributions to the uncertainty budget. Much of this detail, some historical progression, and a few recent findings have not been included in previous papers reporting the results of this experiment. PMID:27308100

  9. Error modelling of quantum Hall array resistance standards

    NASA Astrophysics Data System (ADS)

    Marzano, Martina; Oe, Takehiko; Ortolano, Massimo; Callegaro, Luca; Kaneko, Nobu-Hisa

    2018-04-01

    Quantum Hall array resistance standards (QHARSs) are integrated circuits composed of interconnected quantum Hall effect elements that allow the realization of virtually arbitrary resistance values. In recent years, techniques were presented to efficiently design QHARS networks. An open problem is that of the evaluation of the accuracy of a QHARS, which is affected by contact and wire resistances. In this work, we present a general and systematic procedure for the error modelling of QHARSs, which is based on modern circuit analysis techniques and Monte Carlo evaluation of the uncertainty. As a practical example, this method of analysis is applied to the characterization of a 1 MΩ QHARS developed by the National Metrology Institute of Japan. Software tools are provided to apply the procedure to other arrays.

  10. General methodology: Costing, budgeting, and techniques for benefit-cost and cost-effectiveness analysis

    NASA Technical Reports Server (NTRS)

    Stretchberry, D. M.; Hein, G. F.

    1972-01-01

    The general concepts of costing, budgeting, and benefit-cost ratio and cost-effectiveness analysis are discussed. The three common methods of costing are presented. Budgeting distributions are discussed. The use of discounting procedures is outlined. The benefit-cost ratio and cost-effectiveness analysis is defined and their current application to NASA planning is pointed out. Specific practices and techniques are discussed, and actual costing and budgeting procedures are outlined. The recommended method of calculating benefit-cost ratios is described. A standardized method of cost-effectiveness analysis and long-range planning are also discussed.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The study was conducted to determine the pollutants of concern in the Istanbul metropolitan area, monitoring equipment specifications and monitoring and data analysis procedures for an air quality and meteorological monitoring program. This volume consists of: (1) Introduction; (2) Selection of Pollutants of Concern; (3) Selection of Monitoring Locations; (4) Equipment Specifications; (5) Site Preparation and Security; (6) Standard Operating Procedures; (7) Data Reduction and Analysis; (8) Future Phases; (9) References. Also included are Attachments A through G and List of Tables and List of Figures.

  12. Quality evaluation of LC-MS/MS-based E. coli H antigen typing (MS-H) through label-free quantitative data analysis in a clinical sample setup.

    PubMed

    Cheng, Keding; Sloan, Angela; McCorrister, Stuart; Peterson, Lorea; Chui, Huixia; Drebot, Mike; Nadon, Celine; Knox, J David; Wang, Gehua

    2014-12-01

    The need for rapid and accurate H typing is evident during Escherichia coli outbreak situations. This study explores the transition of MS-H, a method originally developed for rapid H antigen typing of E. coli using LC-MS/MS of flagella digest of reference strains and some clinical strains, to E. coli isolates in clinical scenario through quantitative analysis and method validation. Motile and nonmotile strains were examined in batches to simulate clinical sample scenario. Various LC-MS/MS batch run procedures and MS-H typing rules were compared and summarized through quantitative analysis of MS-H data output for a standard method development. Label-free quantitative data analysis of MS-H typing was proven very useful for examining the quality of MS-H result and the effects of some sample carryovers from motile E. coli isolates. Based on this, a refined procedure and protein identification rule specific for clinical MS-H typing was established and validated. With LC-MS/MS batch run procedure and database search parameter unique for E. coli MS-H typing, the standard procedure maintained high accuracy and specificity in clinical situations, and its potential to be used in a clinical setting was clearly established. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Surface Area Analysis Using the Brunauer-Emmett-Teller (BET) Method: Standard Operating Procedure Series: SOP-C

    DTIC Science & Technology

    2016-09-01

    Method Scientific Operating Procedure Series : SOP-C En vi ro nm en ta l L ab or at or y Jonathon Brame and Chris Griggs September 2016...BET) Method Scientific Operating Procedure Series : SOP-C Jonathon Brame and Chris Griggs Environmental Laboratory U.S. Army Engineer Research and...response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing

  14. Prenatal nutrition services: a cost analysis.

    PubMed

    Splett, P L; Caldwell, H M; Holey, E S; Alton, I R

    1987-02-01

    The scarcity of information about program costs in relation to quality care prompted a cost analysis of prenatal nutrition services in two urban settings. This study examined prenatal nutrition services in terms of total costs, per client costs, per visit costs, and cost per successful outcome. Standard cost-accounting principles were used. Outcome measures, based on written quality assurance criteria, were audited using standard procedures. In the studied programs, nutrition services were delivered for a per client cost of $72 in a health department setting and $121 in a hospital-based prenatal care program. Further analysis illustrates that total and per client costs can be misleading and that costs related to successful outcomes are much higher. The three levels of cost analysis reported provide baseline data for quantifying the costs of providing prenatal nutrition services to healthy pregnant women. Cost information from these cost analysis procedures can be used to guide adjustments in service delivery to assure successful outcomes of nutrition care. Accurate cost and outcome data are necessary prerequisites to cost-effectiveness and cost-benefit studies.

  15. Sensitivity assessment of sea lice to chemotherapeutants: Current bioassays and best practices.

    PubMed

    Marín, S L; Mancilla, J; Hausdorf, M A; Bouchard, D; Tudor, M S; Kane, F

    2017-12-18

    Traditional bioassays are still necessary to test sensitivity of sea lice species to chemotherapeutants, but the methodology applied by the different scientists has varied over time in respect to that proposed in "Sea lice resistance to chemotherapeutants: A handbook in resistance management" (2006). These divergences motivated the organization of a workshop during the Sea Lice 2016 conference "Standardization of traditional bioassay process by sharing best practices." There was an agreement by the attendants to update the handbook. The objective of this article is to provide a baseline analysis of the methodology for traditional bioassays and to identify procedures that need to be addressed to standardize the protocol. The methodology was divided into the following steps: bioassay design; material and equipment; sea lice collection, transportation and laboratory reception; preparation of dilution; parasite exposure; response evaluation; data analysis; and reporting. Information from the presentations of the workshop, and also from other studies, allowed for the identification of procedures inside a given step that need to be standardized as they were reported to be performed differently by the different working groups. Bioassay design and response evaluation were the targeted steps where more procedures need to be analysed and agreed upon. © 2017 John Wiley & Sons Ltd.

  16. Displacement imprinted polymer receptor analysis (DIPRA) for chlorophenolic contaminants in drinking water and packaging materials.

    PubMed

    Nicholls, C; Karim, K; Piletsky, S; Saini, S; Setford, S

    2006-01-15

    The preparation of a molecularly imprinted polymer (MIP) for pentachlorophenol is described together with two alternative reporter derivatives for use in a displacement imprinted polymer receptor analysis (DIPRA) format procedure. In this procedure, alternative reporter molecules were rebound to the synthetic receptor sites and their displacement by the target analyte was employed as the basis of a simple procedure for the measurement of chlorophenols in water and packaging material samples. Water samples were extracted using the standard procedure (EPA 528) and a detection limit of 0.5 microg l(-1) was achieved using the DIPRA detection method, with good agreement between the displacement technique and GC-ECD analysis. A variety of packaging materials, extracted using a buffered detergent solution were also analysed using the DIPRA procedure and showed good agreement with GC results. In addition, investigation of the cross-reactivity of a range of pesticides and materials commonly encountered in environmental analysis indicated the procedure gave good discrimination between pesticides bearing a chlorophenolic moiety and other materials. The procedure is considered highly suitable for use as a rapid field-test method or for incorporation into a test kit device.

  17. Evaluation of the utility of a discrete-trial functional analysis in early intervention classrooms.

    PubMed

    Kodak, Tiffany; Fisher, Wayne W; Paden, Amber; Dickes, Nitasha

    2013-01-01

    We evaluated a discrete-trial functional analysis implemented by regular classroom staff in a classroom setting. The results suggest that the discrete-trial functional analysis identified a social function for each participant and may require fewer staff than standard functional analysis procedures. © Society for the Experimental Analysis of Behavior.

  18. 38 CFR 1.921 - Analysis of costs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... effectiveness of alternative collection techniques, establish guidelines with respect to points at which costs... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Analysis of costs. 1.921... Standards for Collection of Claims § 1.921 Analysis of costs. VA collection procedures should provide for...

  19. When Is Evidence Enough Evidence? A Systematic Review and Meta-Analysis of the Trabectome as a Solo Procedure in Patients with Primary Open-Angle Glaucoma

    PubMed Central

    Chow, Jeffrey T. Y.; Hutnik, Cindy M. L.; Solo, Karla

    2017-01-01

    The purpose of this systematic review and meta-analysis was to examine the availability of evidence for one of the earliest available minimally invasive glaucoma surgery (MIGS) procedures, the Trabectome. Various databases were searched up to December 20, 2016, for any published studies assessing the use of the Trabectome as a solo procedure in patients with primary open-angle glaucoma (POAG). The standardized mean differences (SMD) were calculated for the change in intraocular pressure (IOP) and number of glaucoma mediations used at 1-month, 6-month, and 12-month follow-up. After screening, three studies and one abstract with analyzable data were included. The meta-analysis showed statistically significant reductions in IOP and number of glaucoma medications used at all time points. Though the Trabectome as a solo procedure appears to lower IOP and reduces the number of glaucoma medications, more high-quality studies are required to make definitive conclusions. The difficulty of obtaining evidence may be one of the many obstacles that limit a full understanding of the potential safety and/or efficacy benefits compared to standard treatments. The time has come for a thoughtful and integrated approach with stakeholders to determine optimal access to care strategies for our patients. PMID:28740733

  20. When Is Evidence Enough Evidence? A Systematic Review and Meta-Analysis of the Trabectome as a Solo Procedure in Patients with Primary Open-Angle Glaucoma.

    PubMed

    Chow, Jeffrey T Y; Hutnik, Cindy M L; Solo, Karla; Malvankar-Mehta, Monali S

    2017-01-01

    The purpose of this systematic review and meta-analysis was to examine the availability of evidence for one of the earliest available minimally invasive glaucoma surgery (MIGS) procedures, the Trabectome. Various databases were searched up to December 20, 2016, for any published studies assessing the use of the Trabectome as a solo procedure in patients with primary open-angle glaucoma (POAG). The standardized mean differences (SMD) were calculated for the change in intraocular pressure (IOP) and number of glaucoma mediations used at 1-month, 6-month, and 12-month follow-up. After screening, three studies and one abstract with analyzable data were included. The meta-analysis showed statistically significant reductions in IOP and number of glaucoma medications used at all time points. Though the Trabectome as a solo procedure appears to lower IOP and reduces the number of glaucoma medications, more high-quality studies are required to make definitive conclusions. The difficulty of obtaining evidence may be one of the many obstacles that limit a full understanding of the potential safety and/or efficacy benefits compared to standard treatments. The time has come for a thoughtful and integrated approach with stakeholders to determine optimal access to care strategies for our patients.

  1. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 25 2013-07-01 2013-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  2. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 24 2014-07-01 2014-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  3. 40 CFR 160.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 25 2012-07-01 2012-07-01 false Standard operating procedures. 160.81... GOOD LABORATORY PRACTICE STANDARDS Testing Facilities Operation § 160.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting forth study...

  4. Efficient runner safety assessment during early design phase and root cause analysis

    NASA Astrophysics Data System (ADS)

    Liang, Q. W.; Lais, S.; Gentner, C.; Braun, O.

    2012-11-01

    Fatigue related problems in Francis turbines, especially high head Francis turbines, have been published several times in the last years. During operation the runner is exposed to various steady and unsteady hydraulic loads. Therefore the analysis of forced response of the runner structure requires a combined approach of fluid dynamics and structural dynamics. Due to the high complexity of the phenomena and due to the limitation of computer power, the numerical prediction was in the past too expensive and not feasible for the use as standard design tool. However, due to continuous improvement of the knowledge and the simulation tools such complex analysis has become part of the design procedure in ANDRITZ HYDRO. This article describes the application of most advanced analysis techniques in runner safety check (RSC), including steady state CFD analysis, transient CFD analysis considering rotor stator interaction (RSI), static FE analysis and modal analysis in water considering the added mass effect, in the early design phase. This procedure allows a very efficient interaction between the hydraulic designer and the mechanical designer during the design phase, such that a risk of failure can be detected and avoided in an early design stage.The RSC procedure can also be applied to a root cause analysis (RCA) both to find out the cause of failure and to quickly define a technical solution to meet the safety criteria. An efficient application to a RCA of cracks in a Francis runner is quoted in this article as an example. The results of the RCA are presented together with an efficient and inexpensive solution whose effectiveness could be proven again by applying the described RSC technics. It is shown that, with the RSC procedure developed and applied as standard procedure in ANDRITZ HYDRO such a failure is excluded in an early design phase. Moreover, the RSC procedure is compatible with different commercial and open source codes and can be easily adapted to apply for other types of turbines, such as pump turbines and Pelton runners.

  5. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 33 2013-07-01 2013-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  6. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 33 2012-07-01 2012-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  7. 40 CFR 792.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 32 2014-07-01 2014-07-01 false Standard operating procedures. 792.81... operating procedures. (a) A testing facility shall have standard operating procedures in writing, setting... data generated in the course of a study. All deviations in a study from standard operating procedures...

  8. Establishing powder-handling workflow practices and standard operating procedures: compounding pharmacy and safety.

    PubMed

    Prince, Bryan; Lundevall, Jeremy

    2014-01-01

    This is an ongoing discussion and analysis of powder-handling safety in the compounding pharmacy laboratory that started in the November/December 2013 issue of the International Journal of Pharmaceutical Compounding. In the previous technical article, we established that most chemical powders handled during compounding procedures have an established occupational exposure limits and that powders are micronized during manipulation. All micronized powders handled on an open bench create health hazards to the technicians and create a potential for cross-contamination to the lab environment. Proper identification of the chemical hazard and established standard operating procedures in direct correlation to Good Lab Practices when working inside a powder hood will positively improve the compounding pharmacy's work environment.

  9. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR ISOLATION OF MALFUNCTIONING OR DAMAGED EQUIPMENT (UA-G-2.0)

    EPA Science Inventory

    The purpose of this SOP is to identify and isolate malfunctioning or damaged equipment for the Arizona Border Study. This procedure was followed to ensure consistent data custody, storage, transfer and analysis of a high quality during the Arizona NHEXAS project and the Border s...

  10. Fine fuel moisture measured and estimated in dead Andropogon virginicus in Hawaii

    Treesearch

    Francis M. Fujioka

    1976-01-01

    Fuel moisture estimates generated by the National Fire-Danger Rating System procedure were compared with actual fuel moisture measurements determined from laboratory analysis. Meteorological data required for the NFDRS procedure were collected at two heights to assess the effect of temperature and humidity lapse rates. Standard measurements gave the best results, but...

  11. Grade 11 Students' Interconnected Use of Conceptual Knowledge, Procedural Skills, and Strategic Competence in Algebra: A Mixed Method Study of Error Analysis

    ERIC Educational Resources Information Center

    Egodawatte, Gunawardena; Stoilescu, Dorian

    2015-01-01

    The purpose of this mixed-method study was to investigate grade 11 university/college stream mathematics students' difficulties in applying conceptual knowledge, procedural skills, strategic competence, and algebraic thinking in solving routine (instructional) algebraic problems. A standardized algebra test was administered to thirty randomly…

  12. 18 CFR 725.6 - Principles, standards and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Principles, standards... Responsibilities § 725.6 Principles, standards and procedures. The Principles, Standards and Procedures established... Orders. These Principles, Standards and Procedures are found in 18 CFR parts 710 through 717. ...

  13. Evidence Regarding the Internal Structure: Confirmatory Factor Analysis

    ERIC Educational Resources Information Center

    Lewis, Todd F.

    2017-01-01

    American Educational Research Association (AERA) standards stipulate that researchers show evidence of the internal structure of instruments. Confirmatory factor analysis (CFA) is one structural equation modeling procedure designed to assess construct validity of assessments that has broad applicability for counselors interested in instrument…

  14. PSA discriminator influence on (222)Rn efficiency detection in waters by liquid scintillation counting.

    PubMed

    Stojković, Ivana; Todorović, Nataša; Nikolov, Jovana; Tenjović, Branislava

    2016-06-01

    A procedure for the (222)Rn determination in aqueous samples using liquid scintillation counting (LSC) was evaluated and optimized. Measurements were performed by ultra-low background spectrometer Quantulus 1220™ equipped with PSA (Pulse Shape Analysis) circuit which discriminates alpha/beta spectra. Since calibration procedure is carried out with (226)Ra standard, which has both alpha and beta progenies, it is clear that PSA discriminator has vital importance in order to provide precise spectra separation. Improvement of calibration procedure was done through investigation of PSA discriminator level and, consequentially, the activity of (226)Ra calibration standard influence on (222)Rn efficiency detection. Quench effects on generated spectra i.e. determination of radon efficiency detection were also investigated with quench calibration curve obtained. Radon determination in waters based on modified procedure according to the activity of (226)Ra standard used, dependent on PSA setup, was evaluated with prepared (226)Ra solution samples and drinking water samples with assessment of measurement uncertainty variation included. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. [Procedure of seed quality testing and seed grading standard of Prunus humilis].

    PubMed

    Wen, Hao; Ren, Guang-Xi; Gao, Ya; Luo, Jun; Liu, Chun-Sheng; Li, Wei-Dong

    2014-11-01

    So far there exists no corresponding quality test procedures and grading standards for the seed of Prunus humilis, which is one of the important source of base of semen pruni. Therefor we set up test procedures that are adapt to characteristics of the P. humilis seed through the study of the test of sampling, seed purity, thousand-grain weight, seed moisture, seed viability and germination percentage. 50 cases of seed specimens of P. humilis tested. The related data were analyzed by cluster analysis. Through this research, the seed quality test procedure was developed, and the seed quality grading standard was formulated. The seed quality of each grade should meet the following requirements: for first grade seeds, germination percentage ≥ 68%, thousand-grain weight 383 g, purity ≥ 93%, seed moisture ≤ 5%; for second grade seeds, germination percentage ≥ 26%, thousand-grain weight ≥ 266 g, purity ≥ 73%, seed moisture ≤9%; for third grade seeds, germination percentage ≥ 10%, purity ≥ 50%, thousand-grain weight ≥ 08 g, seed moisture ≤ 13%.

  16. Development of a drift-correction procedure for a direct-reading spectrometer

    NASA Technical Reports Server (NTRS)

    Chapman, G. B., II; Gordon, W. A.

    1977-01-01

    A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

  17. Glycan profiling of monoclonal antibodies using zwitterionic-type hydrophilic interaction chromatography coupled with electrospray ionization mass spectrometry detection.

    PubMed

    Mauko, Lea; Nordborg, Anna; Hutchinson, Joseph P; Lacher, Nathan A; Hilder, Emily F; Haddad, Paul R

    2011-01-15

    We present a new method for the analysis of glycans enzymatically released from monoclonal antibodies (MAbs) employing a zwitterionic-type hydrophilic interaction chromatography (ZIC-HILIC) column coupled with electrospray ionization mass spectrometry (ESI-MS). Both native and reduced glycans were analyzed, and the developed procedure was compared with a standard HILIC procedure used in the pharmaceutical industry whereby fluorescent-labeled glycans are analyzed using a TSK Amide-80 column coupled with fluorescence detection. The separation of isobaric alditol oligosaccharides present in monoclonal antibodies and ribonuclease B is demonstrated, and ZIC-HILIC is shown to have good capability for structural recognition. Glycan profiles obtained with the ZIC-HILIC column and ESI-MS provided detailed information on MAb glycosylation, including identification of some less abundant glycan species, and are consistent with the profiles generated with the standard procedure. This new ZIC-HILIC method offers a simpler and faster approach for glycosylation analysis of therapeutic antibodies. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Protocol for monitoring metals in Ozark National Scenic Riverways, Missouri: Version 1.0

    USGS Publications Warehouse

    Schmitt, Christopher J.; Brumbaugh, William G.; Besser, John M.; Hinck, Jo Ellen; Bowles, David E.; Morrison, Lloyd W.; Williams, Michael H.

    2008-01-01

    The National Park Service is developing a monitoring plan for the Ozark National Scenic Riverways in southeastern Missouri. Because of concerns about the release of lead, zinc, and other metals from lead-zinc mining to streams, the monitoring plan will include mining-related metals. After considering a variety of alternatives, the plan will consist of measuring the concentrations of cadmium, cobalt, lead, nickel, and zinc in composite samples of crayfish (Orconectes luteus or alternate species) and Asian clam (Corbicula fluminea) collected periodically from selected sites. This document, which comprises a protocol narrative and supporting standard operating procedures, describes the methods to be employed prior to, during, and after collection of the organisms, along with procedures for their chemical analysis and quality assurance; statistical analysis, interpretation, and reporting of the data; and for modifying the protocol narrative and supporting standard operating procedures. A list of supplies and equipment, data forms, and sample labels are also included. An example based on data from a pilot study is presented.

  19. The Kjeldahl method as a primary reference procedure for total protein in certified reference materials used in clinical chemistry. I. A review of Kjeldahl methods adopted by laboratory medicine.

    PubMed

    Chromý, Vratislav; Vinklárková, Bára; Šprongl, Luděk; Bittová, Miroslava

    2015-01-01

    We found previously that albumin-calibrated total protein in certified reference materials causes unacceptable positive bias in analysis of human sera. The simplest way to cure this defect is the use of human-based serum/plasma standards calibrated by the Kjeldahl method. Such standards, commutative with serum samples, will compensate for bias caused by lipids and bilirubin in most human sera. To find a suitable primary reference procedure for total protein in reference materials, we reviewed Kjeldahl methods adopted by laboratory medicine. We found two methods recommended for total protein in human samples: an indirect analysis based on total Kjeldahl nitrogen corrected for its nonprotein nitrogen and a direct analysis made on isolated protein precipitates. The methods found will be assessed in a subsequent article.

  20. 40 CFR 98.324 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... paragraphs (d)(1) through (d)(2) of this section. (1) ASTM D1945-03, Standard Test Method for Analysis of... Reformed Gas by Gas Chromatography; ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value...

  1. 40 CFR 98.324 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... paragraphs (d)(1) through (d)(2) of this section. (1) ASTM D1945-03, Standard Test Method for Analysis of... Reformed Gas by Gas Chromatography; ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value...

  2. 40 CFR 98.324 - Monitoring and QA/QC requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... ASTM D1945-03, Standard Test Method for Analysis of Natural Gas by Gas Chromatography; ASTM D1946-90... (Reapproved 2006), Standard Test Method for Heating Value of Gases in Natural Gas Range by Stoichiometric...

  3. 49 CFR 231.33 - Procedure for special approval of existing industry safety appliance standards.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... specific number, dimension, location, and manner of application of each safety appliance contained in the industry standard; (3) Appropriate data or analysis, or both, for FRA to consider in determining whether..., inspection, testing, and maintenance under this part; (ii) Any organizations or bodies that either issued the...

  4. 49 CFR 231.33 - Procedure for special approval of existing industry safety appliance standards.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... specific number, dimension, location, and manner of application of each safety appliance contained in the industry standard; (3) Appropriate data or analysis, or both, for FRA to consider in determining whether..., inspection, testing, and maintenance under this part; (ii) Any organizations or bodies that either issued the...

  5. 49 CFR 231.33 - Procedure for special approval of existing industry safety appliance standards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... specific number, dimension, location, and manner of application of each safety appliance contained in the industry standard; (3) Appropriate data or analysis, or both, for FRA to consider in determining whether..., inspection, testing, and maintenance under this part; (ii) Any organizations or bodies that either issued the...

  6. 49 CFR 231.33 - Procedure for special approval of existing industry safety appliance standards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... specific number, dimension, location, and manner of application of each safety appliance contained in the industry standard; (3) Appropriate data or analysis, or both, for FRA to consider in determining whether..., inspection, testing, and maintenance under this part; (ii) Any organizations or bodies that either issued the...

  7. 75 FR 42791 - Office of New Reactors; Proposed Revision 1 to Standard Review Plan; Section 13.5.1.1 on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-22

    ... NUREG-0800, ``Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants... Procedures--General,'' (Agencywide Documents Access and Management System (ADAMS) Accession No. ML101340264... review of amendment applications and review of design certification and combined license applications for...

  8. 40 CFR 63.705 - Performance test methods and procedures to determine initial compliance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... per gram-mole. Pi = Barometric pressure at the time of sample analysis, millimeters mercury absolute. 760 = Reference or standard pressure, millimeters mercury absolute. 293 = Reference or standard...: ER15DE94.005 (i) The value of RSi is zero unless the owner or operator submits the following information to...

  9. 40 CFR 63.705 - Performance test methods and procedures to determine initial compliance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... per gram-mole. Pi = Barometric pressure at the time of sample analysis, millimeters mercury absolute. 760 = Reference or standard pressure, millimeters mercury absolute. 293 = Reference or standard...: ER15DE94.005 (i) The value of RSi is zero unless the owner or operator submits the following information to...

  10. 40 CFR 63.705 - Performance test methods and procedures to determine initial compliance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... per gram-mole. Pi = Barometric pressure at the time of sample analysis, millimeters mercury absolute. 760 = Reference or standard pressure, millimeters mercury absolute. 293 = Reference or standard...: ER15DE94.005 (i) The value of RSi is zero unless the owner or operator submits the following information to...

  11. 40 CFR 63.705 - Performance test methods and procedures to determine initial compliance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... per gram-mole. Pi = Barometric pressure at the time of sample analysis, millimeters mercury absolute. 760 = Reference or standard pressure, millimeters mercury absolute. 293 = Reference or standard...: ER15DE94.005 (i) The value of RSi is zero unless the owner or operator submits the following information to...

  12. 40 CFR 63.705 - Performance test methods and procedures to determine initial compliance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... per gram-mole. Pi = Barometric pressure at the time of sample analysis, millimeters mercury absolute. 760 = Reference or standard pressure, millimeters mercury absolute. 293 = Reference or standard...: ER15DE94.005 (i) The value of RSi is zero unless the owner or operator submits the following information to...

  13. A Standardized Soil Ecotoxicological Test Using Red Worms (Eisenia fetida).

    ERIC Educational Resources Information Center

    Paradise, Christopher J.

    2001-01-01

    Describes a simple, inexpensive test for soil contamination that can be used in a variety of courses to examine the effects of soil toxicity, to practice standardized laboratory procedures, to study experimental design and data analysis, or to investigate earthworm ecology. Presents background information along with details regarding equipment,…

  14. Optimized Standard Operating Procedures for the Analysis of Cerebrospinal Fluid Aβ42 and the Ratios of Aβ Isoforms Using Low Protein Binding Tubes.

    PubMed

    Vanderstichele, Hugo Marcel Johan; Janelidze, Shorena; Demeyer, Leentje; Coart, Els; Stoops, Erik; Herbst, Victor; Mauroo, Kimberley; Brix, Britta; Hansson, Oskar

    2016-05-31

    Reduced cerebrospinal fluid (CSF) concentration of amyloid-β1-42 (Aβ1-42) reflects the presence of amyloidopathy in brains of subjects with Alzheimer's disease (AD). To qualify the use of Aβ1-42/Aβ1-40 for improvement of standard operating procedures (SOP) for measurement of CSF Aβ with a focus on CSF collection, storage, and analysis. Euroimmun ELISAs for CSF Aβ isoforms were used to set up a SOP with respect to recipient properties (low binding, polypropylene), volume of tubes, freeze/thaw cycles, addition of detergents (Triton X-100, Tween-20) in collection or storage tubes or during CSF analysis. Data were analyzed with linear repeated measures and mixed effects models. Optimization of CSF analysis included a pre-wash of recipients (e.g., tubes, 96-well plates) before sample analysis. Using the Aβ1-42/Aβ1-40 ratio, in contrast to Aβ1-42, eliminated effects of tube type, additional freeze/thaw cycles, or effect of CSF volumes for polypropylene storage tubes. 'Low binding' tubes reduced the loss of Aβ when aliquoting CSF or in function of additional freeze/thaw cycles. Addition of detergent in CSF collection tubes resulted in an almost complete absence of variation in function of collection procedures, but affected the concentration of Aβ isoforms in the immunoassay. The ratio of Aβ1-42/Aβ1-40 is a more robust biomarker than Aβ1-42 toward (pre-) analytical interfering factors. Further, 'low binding' recipients and addition of detergent in collection tubes are able to remove effects of SOP-related confounding factors. Integration of the Aβ1-42/Aβ1-40 ratio and 'low-binding tubes' into guidance criteria may speed up worldwide standardization of CSF biomarker analysis.

  15. Laboratory diagnosis of creatine deficiency syndromes: a technical standard and guideline of the American College of Medical Genetics and Genomics.

    PubMed

    Sharer, J Daniel; Bodamer, Olaf; Longo, Nicola; Tortorelli, Silvia; Wamelink, Mirjam M C; Young, Sarah

    2017-02-01

    Disclaimer: These ACMG Standards and Guidelines are intended as an educational resource for clinical laboratory geneticists to help them provide quality clinical laboratory genetic services. Adherence to these standards and guidelines is voluntary and does not necessarily assure a successful medical outcome. These Standards and Guidelines should not be considered inclusive of all proper procedures and tests or exclusive of others that are reasonably directed to obtaining the same results. In determining the propriety of any specific procedure or test, clinical laboratory geneticists should apply their professional judgment to the specific circumstances presented by the patient or specimen. Clinical laboratory geneticists are encouraged to document in the patient's record the rationale for the use of a particular procedure or test, whether or not it is in conformance with these Standards and Guidelines. They also are advised to take notice of the date any particular guideline was adopted, and to consider other relevant medical and scientific information that becomes available after that date. It also would be prudent to consider whether intellectual property interests may restrict the performance of certain tests and other procedures.Cerebral creatine deficiency syndromes are neurometabolic conditions characterized by intellectual disability, seizures, speech delay, and behavioral abnormalities. Several laboratory methods are available for preliminary and confirmatory diagnosis of these conditions, including measurement of creatine and related metabolites in biofluids using liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry, enzyme activity assays in cultured cells, and DNA sequence analysis. These guidelines are intended to standardize these procedures to help optimize the diagnosis of creatine deficiency syndromes. While biochemical methods are emphasized, considerations for confirmatory molecular testing are also discussed, along with variables that influence test results and interpretation.Genet Med 19 2, 256-263.

  16. 40 CFR 51.357 - Test procedures and standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Test procedures and standards. 51.357... Requirements § 51.357 Test procedures and standards. Written test procedures and pass/fail standards shall be established and followed for each model year and vehicle type included in the program. (a) Test procedure...

  17. A posteriori noise estimation in variable data sets. With applications to spectra and light curves

    NASA Astrophysics Data System (ADS)

    Czesla, S.; Molle, T.; Schmitt, J. H. M. M.

    2018-01-01

    Most physical data sets contain a stochastic contribution produced by measurement noise or other random sources along with the signal. Usually, neither the signal nor the noise are accurately known prior to the measurement so that both have to be estimated a posteriori. We have studied a procedure to estimate the standard deviation of the stochastic contribution assuming normality and independence, requiring a sufficiently well-sampled data set to yield reliable results. This procedure is based on estimating the standard deviation in a sample of weighted sums of arbitrarily sampled data points and is identical to the so-called DER_SNR algorithm for specific parameter settings. To demonstrate the applicability of our procedure, we present applications to synthetic data, high-resolution spectra, and a large sample of space-based light curves and, finally, give guidelines to apply the procedure in situation not explicitly considered here to promote its adoption in data analysis.

  18. Ultrasound extraction and thin layer chromatography-flame ionization detection analysis of the lipid fraction in marine mucilage samples.

    PubMed

    Mecozzi, M; Amici, M; Romanelli, G; Pietrantonio, E; Deluca, A

    2002-07-19

    This paper reports an analytical procedure based on ultrasound to extract lipids in marine mucilage samples. The experimental conditions of the ultrasound procedure (solvent and time) were identified by a FT-IR study performed on different standard samples of lipids and of a standard humic sample, before and after the sonication treatment. This study showed that diethyl ether was a more suitable solvent than methanol for the ultrasonic extraction of lipids from environmental samples because it allowed to minimize the possible oxidative modifications of lipids due to the acoustic cavitation phenomena. The optimized conditions were applied to the extraction of total lipid amount in marine mucilage samples and TLC-flame ionization detection analysis was used to identify the relevant lipid sub-fractions present in samples.

  19. A Standard Procedure for Conducting Cognitive Task Analysis.

    ERIC Educational Resources Information Center

    Redding, Richard E.

    Traditional methods for task analysis have been largely based on the Instructional Systems Development (ISD) model, which is widely used throughout industry and the military. The first part of this document gives an overview of cognitive task analysis, which is conducted within the first phase of ISD. The following steps of cognitive task analysis…

  20. Quantitative Assay for Starch by Colorimetry Using a Desktop Scanner

    ERIC Educational Resources Information Center

    Matthews, Kurt R.; Landmark, James D.; Stickle, Douglas F.

    2004-01-01

    The procedure to produce standard curve for starch concentration measurement by image analysis using a color scanner and computer for data acquisition and color analysis is described. Color analysis is performed by a Visual Basic program that measures red, green, and blue (RGB) color intensities for pixels within the scanner image.

  1. Design and analysis of roll cage

    NASA Astrophysics Data System (ADS)

    Angadi, Gurusangappa; Chetan, S.

    2018-04-01

    Wildlife fire fighting vehicles are used to extinguish fires in forests, in this process vehicles face falling objects like rocks, tree branches and other objects. Also due to uneven conditions of the terrain like cliff edges, uneven surfaces etc. makes the vehicle to roll over and these can cause injuries to both the driver and the operator. Roll over of a vehicle is a common incident which makes fatal injuries to the operator and also stands next to the crash accidents. In order to reduce the injury level and continuous roll over of the vehicle it is necessary to equip suitable roll cage according to standards of vehicle. In this present work roll cage for pump operator in wildfire fighting vehicle is designed and analysis is carried out in computer simulated environment when seating position of operator seated outside of the cabin. According to NFPA 1906 standards wildlife fire apparatus, Design and Test procedures that are carried out in Hyperworks maintaining SAE J1194.1983 standards. G load case, roof crush analysis and pendulum impact analysis tests are carried out on roll cage to ensure the saftey of design. These load cases are considerd to satisfy the situation faced in forest terrain. In these test procedures roll cage is analysed for stresses and deformation in various load cases. After recording results these are compared with standards mentioned in SAE J1194.1983.

  2. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF HAIR SAMPLES FOR TRACE METALS AND ARSENIC (RTI/ACS-209-046)

    EPA Science Inventory

    This protocol describes the procedures for the collection, storage, and shipping of human scalp hair samples for trace metals and arsenic or potential adduct analysis. Scalp hair samples were collected from each participant that agreed to provide the sample. Thinning shears were ...

  3. Meta-analysis of the technical performance of an imaging procedure: guidelines and statistical methodology.

    PubMed

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2015-02-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test-retest repeatability data for illustrative purposes. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. Meta-analysis of the technical performance of an imaging procedure: Guidelines and statistical methodology

    PubMed Central

    Huang, Erich P; Wang, Xiao-Feng; Choudhury, Kingshuk Roy; McShane, Lisa M; Gönen, Mithat; Ye, Jingjing; Buckler, Andrew J; Kinahan, Paul E; Reeves, Anthony P; Jackson, Edward F; Guimaraes, Alexander R; Zahlmann, Gudrun

    2017-01-01

    Medical imaging serves many roles in patient care and the drug approval process, including assessing treatment response and guiding treatment decisions. These roles often involve a quantitative imaging biomarker, an objectively measured characteristic of the underlying anatomic structure or biochemical process derived from medical images. Before a quantitative imaging biomarker is accepted for use in such roles, the imaging procedure to acquire it must undergo evaluation of its technical performance, which entails assessment of performance metrics such as repeatability and reproducibility of the quantitative imaging biomarker. Ideally, this evaluation will involve quantitative summaries of results from multiple studies to overcome limitations due to the typically small sample sizes of technical performance studies and/or to include a broader range of clinical settings and patient populations. This paper is a review of meta-analysis procedures for such an evaluation, including identification of suitable studies, statistical methodology to evaluate and summarize the performance metrics, and complete and transparent reporting of the results. This review addresses challenges typical of meta-analyses of technical performance, particularly small study sizes, which often causes violations of assumptions underlying standard meta-analysis techniques. Alternative approaches to address these difficulties are also presented; simulation studies indicate that they outperform standard techniques when some studies are small. The meta-analysis procedures presented are also applied to actual [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) test–retest repeatability data for illustrative purposes. PMID:24872353

  5. 10 CFR 434.510 - Standard calculation procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Standard calculation procedure. 434.510 Section 434.510... HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard calculation procedure. 510.1The Standard Calculation Procedure consists of methods and assumptions for...

  6. Effects of computer-based training on procedural modifications to standard functional analyses.

    PubMed

    Schnell, Lauren K; Sidener, Tina M; DeBar, Ruth M; Vladescu, Jason C; Kahng, SungWoo

    2018-01-01

    Few studies have evaluated methods for training decision-making when functional analysis data are undifferentiated. The current study evaluated computer-based training to teach 20 graduate students to arrange functional analysis conditions, analyze functional analysis data, and implement procedural modifications. Participants were exposed to training materials using interactive software during a 1-day session. Following the training, mean scores on the posttest, novel cases probe, and maintenance probe increased for all participants. These results replicate previous findings during a 1-day session and include a measure of participant acceptability of the training. Recommendations for future research on computer-based training and functional analysis are discussed. © 2017 Society for the Experimental Analysis of Behavior.

  7. 29 CFR 1607.9 - No assumption of validity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of validity. The enforcement agencies will take into account the fact that a thorough job analysis... professional standards enhance the probability that the selection procedure is valid for the job. ...

  8. Mode-Stirred Method Implementation for HIRF Susceptibility Testing and Results Comparison with Anechoic Method

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.

    2001-01-01

    This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.

  9. A Critical Analysis of the Body of Work Method for Setting Cut-Scores

    ERIC Educational Resources Information Center

    Radwan, Nizam; Rogers, W. Todd

    2006-01-01

    The recent increase in the use of constructed-response items in educational assessment and the dissatisfaction with the nature of the decision that the judges must make using traditional standard-setting methods created a need to develop new and effective standard-setting procedures for tests that include both multiple-choice and…

  10. 76 FR 7235 - Office of New Reactors; Proposed Revision 1 to Standard Review Plan, Section 13.5.1.1 on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-09

    ... NUREG-0800, ``Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants... Procedures--General,'' (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110100193... associated with the review of amendment applications and review of design certification and combined license...

  11. Medical Abortion Provided by Nurse-Midwives or Physicians in a High Resource Setting: A Cost-Effectiveness Analysis.

    PubMed

    Sjöström, Susanne; Kopp Kallner, Helena; Simeonova, Emilia; Madestam, Andreas; Gemzell-Danielsson, Kristina

    2016-01-01

    The objective of the present study is to calculate the cost-effectiveness of early medical abortion performed by nurse-midwifes in comparison to physicians in a high resource setting where ultrasound dating is part of the protocol. Non-physician health care professionals have previously been shown to provide medical abortion as effectively and safely as physicians, but the cost-effectiveness of such task shifting remains to be established. A cost effectiveness analysis was conducted based on data from a previously published randomized-controlled equivalence study including 1180 healthy women randomized to the standard procedure, early medical abortion provided by physicians, or the intervention, provision by nurse-midwifes. A 1.6% risk difference for efficacy defined as complete abortion without surgical interventions in favor of midwife provision was established which means that for every 100 procedures, the intervention treatment resulted in 1.6 fewer incomplete abortions needing surgical intervention than the standard treatment. The average direct and indirect costs and the incremental cost-effectiveness ratio (ICER) were calculated. The study was conducted at a university hospital in Stockholm, Sweden. The average direct costs per procedure were EUR 45 for the intervention compared to EUR 58.3 for the standard procedure. Both the cost and the efficacy of the intervention were superior to the standard treatment resulting in a negative ICER at EUR -831 based on direct costs and EUR -1769 considering total costs per surgical intervention avoided. Early medical abortion provided by nurse-midwives is more cost-effective than provision by physicians. This evidence provides clinicians and decision makers with an important tool that may influence policy and clinical practice and eventually increase numbers of abortion providers and reduce one barrier to women's access to safe abortion.

  12. Basics of compounding: considerations for implementing United States pharmacopeia chapter 797 pharmaceutical compounding-sterile preparations, part 16: suggested standard operating procedures.

    PubMed

    Okeke, Claudia C; Allen, Loyd V

    2009-01-01

    The standard operating procedures suggested in this article are presented to compounding pharmacies to ensure the quality of the environment in which a CSP is prepared. Since United States Pharmacopeia Chapter 797 provides minimum standards, each facility should aim for best practice gold standard. The standard operating procedures should be tailored to meet the expectations and design of each facility. Compounding personnel are expected to know and understand each standard operating procedure to allow for complete execution of the procedures.

  13. Evaluation of noise pollution level in the operating rooms of hospitals: A study in Iran.

    PubMed

    Giv, Masoumeh Dorri; Sani, Karim Ghazikhanlou; Alizadeh, Majid; Valinejadi, Ali; Majdabadi, Hesamedin Askari

    2017-06-01

    Noise pollution in the operating rooms is one of the remaining challenges. Both patients and physicians are exposed to different sound levels during the operative cases, many of which can last for hours. This study aims to evaluate the noise pollution in the operating rooms during different surgical procedures. In this cross-sectional study, sound level in the operating rooms of Hamadan University-affiliated hospitals (totally 10) in Iran during different surgical procedures was measured using B&K sound meter. The gathered data were compared with national and international standards. Statistical analysis was performed using descriptive statistics and one-way ANOVA, t -test, and Pearson's correlation test. Noise pollution level at majority of surgical procedures is higher than national and international documented standards. The highest level of noise pollution is related to orthopedic procedures, and the lowest one related to laparoscopic and heart surgery procedures. The highest and lowest registered sound level during the operation was 93 and 55 dB, respectively. Sound level generated by equipments (69 ± 4.1 dB), trolley movement (66 ± 2.3 dB), and personnel conversations (64 ± 3.9 dB) are the main sources of noise. The noise pollution of operating rooms are higher than available standards. The procedure needs to be corrected for achieving the proper conditions.

  14. Formalizing the Austrian Procedure Catalogue: A 4-step methodological analysis approach.

    PubMed

    Neururer, Sabrina Barbara; Lasierra, Nelia; Peiffer, Karl Peter; Fensel, Dieter

    2016-04-01

    Due to the lack of an internationally accepted and adopted standard for coding health interventions, Austria has established its own country-specific procedure classification system - the Austrian Procedure Catalogue (APC). Even though the APC is an elaborate coding standard for medical procedures, it has shortcomings that limit its usability. In order to enhance usability and usefulness, especially for research purposes and e-health applications, we developed an ontologized version of the APC. In this paper we present a novel four-step approach for the ontology engineering process, which enables accurate extraction of relevant concepts for medical ontologies from written text. The proposed approach for formalizing the APC consists of the following four steps: (1) comparative pre-analysis, (2) definition analysis, (3) typological analysis, and (4) ontology implementation. The first step contained a comparison of the APC to other well-established or elaborate health intervention coding systems in order to identify strengths and weaknesses of the APC. In the second step, a list of definitions of medical terminology used in the APC was obtained. This list of definitions was used as input for Step 3, in which we identified the most important concepts to describe medical procedures using the qualitative typological analysis approach. The definition analysis as well as the typological analysis are well-known and effective methods used in social sciences, but not commonly employed in the computer science or ontology engineering domain. Finally, this list of concepts was used in Step 4 to formalize the APC. The pre-analysis highlighted the major shortcomings of the APC, such as the lack of formal definition, leading to implicitly available, but not directly accessible information (hidden data), or the poor procedural type classification. After performing the definition and subsequent typological analyses, we were able to identify the following main characteristics of health interventions: (1) Procedural type, (2) Anatomical site, (3) Medical device, (4) Pathology, (5) Access, (6) Body system, (7) Population, (8) Aim, (9) Discipline, (10) Technique, and (11) Body Function. These main characteristics were taken as input of classes for the formalization of the APC. We were also able to identify relevant relations between classes. The proposed four-step approach for formalizing the APC provides a novel, systematically developed, strong framework to semantically enrich procedure classifications. Although this methodology was designed to address the particularities of the APC, the included methods are based on generic analysis tasks, and therefore can be re-used to provide a systematic representation of other procedure catalogs or classification systems and hence contribute towards a universal alignment of such representations, if desired. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Standards for data acquisition and software-based analysis of in vivo electroencephalography recordings from animals. A TASK1-WG5 report of the AES/ILAE Translational Task Force of the ILAE.

    PubMed

    Moyer, Jason T; Gnatkovsky, Vadym; Ono, Tomonori; Otáhal, Jakub; Wagenaar, Joost; Stacey, William C; Noebels, Jeffrey; Ikeda, Akio; Staley, Kevin; de Curtis, Marco; Litt, Brian; Galanopoulou, Aristea S

    2017-11-01

    Electroencephalography (EEG)-the direct recording of the electrical activity of populations of neurons-is a tremendously important tool for diagnosing, treating, and researching epilepsy. Although standard procedures for recording and analyzing human EEG exist and are broadly accepted, there are no such standards for research in animal models of seizures and epilepsy-recording montages, acquisition systems, and processing algorithms may differ substantially among investigators and laboratories. The lack of standard procedures for acquiring and analyzing EEG from animal models of epilepsy hinders the interpretation of experimental results and reduces the ability of the scientific community to efficiently translate new experimental findings into clinical practice. Accordingly, the intention of this report is twofold: (1) to review current techniques for the collection and software-based analysis of neural field recordings in animal models of epilepsy, and (2) to offer pertinent standards and reporting guidelines for this research. Specifically, we review current techniques for signal acquisition, signal conditioning, signal processing, data storage, and data sharing, and include applicable recommendations to standardize collection and reporting. We close with a discussion of challenges and future opportunities, and include a supplemental report of currently available acquisition systems and analysis tools. This work represents a collaboration on behalf of the American Epilepsy Society/International League Against Epilepsy (AES/ILAE) Translational Task Force (TASK1-Workgroup 5), and is part of a larger effort to harmonize video-EEG interpretation and analysis methods across studies using in vivo and in vitro seizure and epilepsy models. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  16. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE FOR LABORATORY ANALYSIS OF HAIR SAMPLES FOR MERCURY (RTI-L-1.0)

    EPA Science Inventory

    The purpose of this protocol is to provide guidelines for the analysis of hair samples for total mercury by cold vapor atomic fluorescence (CVAFS) spectrometry. This protocol describes the methodology and all other analytical aspects involved in the analysis. Keywords: hair; s...

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/MS (BCO-L-15.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...

  18. Real-time MRI guidance of cardiac interventions.

    PubMed

    Campbell-Washburn, Adrienne E; Tavallaei, Mohammad A; Pop, Mihaela; Grant, Elena K; Chubb, Henry; Rhode, Kawal; Wright, Graham A

    2017-10-01

    Cardiac magnetic resonance imaging (MRI) is appealing to guide complex cardiac procedures because it is ionizing radiation-free and offers flexible soft-tissue contrast. Interventional cardiac MR promises to improve existing procedures and enable new ones for complex arrhythmias, as well as congenital and structural heart disease. Guiding invasive procedures demands faster image acquisition, reconstruction and analysis, as well as intuitive intraprocedural display of imaging data. Standard cardiac MR techniques such as 3D anatomical imaging, cardiac function and flow, parameter mapping, and late-gadolinium enhancement can be used to gather valuable clinical data at various procedural stages. Rapid intraprocedural image analysis can extract and highlight critical information about interventional targets and outcomes. In some cases, real-time interactive imaging is used to provide a continuous stream of images displayed to interventionalists for dynamic device navigation. Alternatively, devices are navigated relative to a roadmap of major cardiac structures generated through fast segmentation and registration. Interventional devices can be visualized and tracked throughout a procedure with specialized imaging methods. In a clinical setting, advanced imaging must be integrated with other clinical tools and patient data. In order to perform these complex procedures, interventional cardiac MR relies on customized equipment, such as interactive imaging environments, in-room image display, audio communication, hemodynamic monitoring and recording systems, and electroanatomical mapping and ablation systems. Operating in this sophisticated environment requires coordination and planning. This review provides an overview of the imaging technology used in MRI-guided cardiac interventions. Specifically, this review outlines clinical targets, standard image acquisition and analysis tools, and the integration of these tools into clinical workflow. 1 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2017;46:935-950. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Tear cytokine profile as a noninvasive biomarker of inflammation for ocular surface diseases: standard operating procedures.

    PubMed

    Wei, Yi; Gadaria-Rathod, Neha; Epstein, Seth; Asbell, Penny

    2013-12-23

    To provide standard operating procedures (SOPs) for measuring tear inflammatory cytokine concentrations and to validate the resulting profile as a minimally invasive objective metric and biomarker of ocular surface inflammation for use in multicenter clinical trials on dry eye disease (DED). Standard operating procedures were established and then validated with cytokine standards, quality controls, and masked tear samples collected from local and distant clinical sites. The concentrations of the inflammatory cytokines in tears were quantified using a high-sensitivity human cytokine multiplex kit. A panel of inflammatory cytokines was initially investigated, from which four key inflammatory cytokines (IL-1β, IL-6, INF-γ, and TNF-α) were chosen. Results with cytokine standards statistically satisfied the manufacturer's quality control criteria. Results with pooled tear samples were highly reproducible and reliable with tear volumes ranging from 4 to 10 μL. Incorporation of the SOPs into clinical trials was subsequently validated. Tear samples were collected at a distant clinical site, stored, and shipped to our Biomarker Laboratory, where a masked analysis of the four tear cytokines was successfully performed. Tear samples were also collected from a feasibility study on DED. Inflammatory cytokine concentrations were decreased in tears of subjects who received anti-inflammatory treatment. Standard operating procedures for human tear cytokine assessment suitable for multicenter clinical trials were established. Tear cytokine profiling using these SOPs may provide objective metrics useful for diagnosing, classifying, and analyzing treatment efficacy in inflammatory conditions of the ocular surface, which may further elucidate the mechanisms involved in the pathogenesis of ocular surface disease.

  20. Setting technical standards for visual assessment procedures

    Treesearch

    Kenneth H. Craik; Nickolaus R. Feimer

    1979-01-01

    Under the impetus of recent legislative and administrative mandates concerning analysis and management of the landscape, governmental agencies are being called upon to adopt or develop visual resource and impact assessment (VRIA) systems. A variety of techniques that combine methods of psychological assessment and landscape analysis to serve these purposes is being...

  1. METHOD FOR THE DETERMINATION OF PERCHLORATE ANION IN PLANT AND SOLID MATRICES BY ION CHROMATOGRAPHY

    EPA Science Inventory

    A standardized method for the analysis of perchlorate in plants was developed, based on dry weight, and applied to the analysis of plant organs, foodstuffs, and plant products. The procedure greatly reduced the ionic interferences in water extracts of plant materials. Ion chro...

  2. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF POLAR PERSISTENT ORGANIC POLLUTANTS (SOP-5.13)

    EPA Science Inventory

    The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.

  3. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING DRINKING WATER SAMPLES FOR ANALYSIS OF PERSISTENT ORGANIC POLLUTANTS (SOP 5.23)

    EPA Science Inventory

    The method for extracting and preparing a drinking water sample for analysis of atrazine is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/ mass spectrometry.

  4. GUIDELINES FOR TRAINING SITUATION ANALYSIS (TSA). FINAL REPORT.

    ERIC Educational Resources Information Center

    CHENZOFF, ANDREW P.; FOLLEY, JOHN D., JR.

    THESE GUIDELINES REPRESENT A TEXTBOOK FOR INSTRUCTION IN THREE PHASES OF TRAINING SITUATION ANALYSIS (TSA), A STANDARDIZED PROCEDURE DEVELOPED BY THE NAVAL TRAINING DEVICE CENTER FOR SYSTEMATICALLY GATHERING AND INTERPRETING THE INFORMATION RELEVANT TO THE PLANNING OF TRAINING AND TRAINING DEVICES. THREE PHASES OF TSA ARE DESCRIBED IN…

  5. DETERMINATION OF PERCHLORATE AT PARTS-PER-BILLION LEVELS IN PLANTS BY ION CHROMATOGRAPHY

    EPA Science Inventory

    A standardized method for the analysis of perchlorate in plants was developed, based on dry weight, and applied to the analysis of plant organs, foodstuffs, and plant products. The procedure greatly reduced the ionic interferences in water extracts of plant materials. The high ba...

  6. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  7. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  8. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  9. 40 CFR 610.22 - Device integrity.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... RETROFIT DEVICES Test Procedures and Evaluation Criteria Evaluation Criteria for the Preliminary Analysis... to which device manufacture is standardized by means of drawings, specifications, and other... which test data support (b), (c) and (d). ...

  10. Pediatric Drowning: A Standard Operating Procedure to Aid the Prehospital Management of Pediatric Cardiac Arrest Resulting From Submersion.

    PubMed

    Best, Rebecca R; Harris, Benjamin H L; Walsh, Jason L; Manfield, Timothy

    2017-05-08

    Drowning is one of the leading causes of death in children. Resuscitating a child following submersion is a high-pressure situation, and standard operating procedures can reduce error. Currently, the Resuscitation Council UK guidance does not include a standard operating procedure on pediatric drowning. The objective of this project was to design a standard operating procedure to improve outcomes of drowned children. A literature review on the management of pediatric drowning was conducted. Relevant publications were used to develop a standard operating procedure for management of pediatric drowning. A concise standard operating procedure was developed for resuscitation following pediatric submersion. Specific recommendations include the following: the Heimlich maneuver should not be used in this context; however, prolonged resuscitation and therapeutic hypothermia are recommended. This standard operating procedure is a potentially useful adjunct to the Resuscitation Council UK guidance and should be considered for incorporation into its next iteration.

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF SOIL OR HOUSE DUST SAMPLES USING CHLORPYRIFOS ELISA SAMPLES (BCO-L-1.0)

    EPA Science Inventory

    This abstract is included for completeness of documentation, but this SOP was not used in the study.

    The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...

  12. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION OF PERSONAL AIR SAMPLES FOR ANALYSIS OF PESTICIDES OR METALS (UA-F-14.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the procedure for sampling personal air for metals and pesticides during a predetermined time period. The SOP includes the set up of the samplers for collection of either a metals sample or a pesticides sample, the calibration and initial c...

  13. Effect of implementing instructional videos in a physical examination course: an alternative paradigm for chiropractic physical examination teaching.

    PubMed

    Zhang, Niu; Chawla, Sudeep

    2012-01-01

    This study examined the effect of implementing instructional video in ophthalmic physical examination teaching on chiropractic students' laboratory physical examination skills and written test results. Instructional video clips of ophthalmic physical examination, consisting of both standard procedures and common mistakes, were created and used for laboratory teaching. The video clips were also available for student review after class. Students' laboratory skills and written test results were analyzed and compared using one-way analysis of variance (ANOVA) and post hoc multiple comparison tests among three study cohorts: the comparison cohort who did not utilize the instructional videos as a tool, the standard video cohort who viewed only the standard procedure of video clips, and the mistake-referenced video cohort who viewed video clips containing both standard procedure and common mistakes. One-way ANOVA suggested a significant difference of lab results among the three cohorts. Post hoc multiple comparisons further revealed that the mean scores of both video cohorts were significantly higher than that of the comparison cohort (p < .001). There was, however, no significant difference of the mean scores between the two video cohorts (p > .05). However, the percentage of students having a perfect score was the highest in the mistake-referenced video cohort. There was no significant difference of written test scores among all three cohorts (p > .05). The instructional video of the standard procedure improves chiropractic students' ophthalmic physical examination skills, which may be further enhanced by implementing a mistake-referenced instructional video.

  14. 21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... accordance with its standard operating procedure of the information identified in paragraphs (a)(1), (a)(2... shall establish a written standard operating procedure for the collection, maintenance, and auditing of... standard operating procedure: (1) Data collection and recording procedures, which shall include a procedure...

  15. Management of recurrent stress urinary incontinence after burch and sling procedures.

    PubMed

    Zimmern, Philippe E; Gormley, E Ann; Stoddard, Anne M; Lukacz, Emily S; Sirls, Larry; Brubaker, Linda; Norton, Peggy; Oliphant, Sallie S; Wilson, Tracey

    2016-03-01

    To examine treatment options selected for recurrent stress urinary incontinence (rSUI) in follow-up after Burch, autologous fascial and synthetic midurethral sling (MUS) procedures. We performed a secondary analysis of the SISTER and ToMUS trials of participants who underwent primary stress urinary incontinence (SUI) treatment (without prior SUI surgery or concomitant procedures). Using Kaplan-Meier analysis, retreatment-free survival rates by initial surgical procedure were compared. Mean MESA (Medical Epidemiologic and Social Aspects of Aging) stress index was also compared between those retreated for rSUI compared to those not retreated. Half of the women in the SISTEr trial met inclusion criteria for this analysis (329/655, 174 Burch and 155 fascial sling), as did 444/597 (74%) of subjects in ToMUS (221 transobturator midurethral sling (TMUS), and 223 retropubic midurethral sling (RMUS). Types of surgical retreatment included autologous fascial sling (19), synthetic sling (1), and bulking agent (18). Five-year retreatment free survival rates (and standard errors) were 87% (3%), 96% (2%), 97% (1%), and 99% (0.7%) for Burch, autologous fascial sling, TMUS, and RMUS groups respectively (P < 0.0001). For all index surgery groups, the mean MESA stress index at last visit prior to retreatment for those retreated (n = 23) was significantly higher than mean MESA stress index at last visit for those not retreated (n = 645) (P < 0.0001). In these cohorts, 6% of women after standard anti-incontinence procedures were retreated within 5 years, mostly with injection therapy or autologous fascial sling. Not all women with rSUI chose surgical retreatment. © 2015 Wiley Periodicals, Inc.

  16. Management of recurrent stress urinary incontinence after Burch and sling procedures

    PubMed Central

    Zimmern, Philippe; Gormley, E. Ann; Stoddard, Anne M.; Lukacz, Emily S.; Sirls, Larry; Brubaker, Linda; Norton, Peggy; Oliphant, Sallie S.; Wilson, Tracey

    2014-01-01

    Introduction To examine treatment options selected for recurrent stress urinary incontinence (rSUI) in follow-up after Burch, autologous fascial and synthetic midurethral sling (MUS) procedures. Methods We performed a secondary analysis of the SISTER and ToMUS trials of participants who underwent primary stress urinary incontinence (SUI) treatment (without prior SUI surgery or concomitant procedures). Using Kaplan-Meier analysis, retreatment-free survival rates by initial surgical procedure were compared. Mean MESA (Medical Epidemiologic and Social Aspects of Aging) stress index was also compared between those retreated for rSUI compared to those not retreated. Results Half of the women in the SISTEr trial met inclusion criteria for this analysis (329/655, 174 Burch and 155 fascial sling), as did 444/597 (74%) of subjects in ToMUS (221 transobturator midurethral sling (TMUS), and 223 retropubic midurethral sling (RMUS). Types of surgical retreatment included autologous fascial sling (19), synthetic sling (1), and bulking agent (18). Five-year retreatment free survival rates (and standard errors) were 87% (3%), 96% (2%), 97% (1%) and 99% (0.7%) for Burch, autologous fascial sling, TMUS, and RMUS groups respectively (p <0.0001). For all index surgery groups, the mean MESA stress index at last visit prior to retreatment for those retreated (n = 23) was significantly higher than mean MESA stress index at last visit for those not retreated (n = 645) (p <0.0001). Conclusion In these cohorts, 6% of women after standard anti-incontinence procedures were retreated within 5 years, mostly with injection therapy or autologous fascial sling. Not all women with rSUI chose surgical retreatment. PMID:25598512

  17. Development of a new procedure for the determination of captopril in pharmaceutical formulations employing chemiluminescence and a multicommuted flow analysis approach.

    PubMed

    Lima, Manoel J A; Fernandes, Ridvan N; Tanaka, Auro A; Reis, Boaventura F

    2016-02-01

    This paper describes a new technique for the determination of captopril in pharmaceutical formulations, implemented by employing multicommuted flow analysis. The analytical procedure was based on the reaction between hypochlorite and captopril. The remaining hypochlorite oxidized luminol that generated electromagnetic radiation detected using a homemade luminometer. To the best of our knowledge, this is the first time that this reaction has been exploited for the determination of captopril in pharmaceutical products, offering a clean analytical procedure with minimal reagent usage. The effectiveness of the proposed procedure was confirmed by analyzing a set of pharmaceutical formulations. Application of the paired t-test showed that there was no significant difference between the data sets at a 95% confidence level. The useful features of the new analytical procedure included a linear response for captopril concentrations in the range 20.0-150.0 µmol/L (r = 0.997), a limit of detection (3σ) of 2.0 µmol/L, a sample throughput of 164 determinations per hour, reagent consumption of 9 µg luminol and 42 µg hypochlorite per determination and generation of 0.63 mL of waste. A relative standard deviation of 1% (n = 6) for a standard solution containing 80 µmol/L captopril was also obtained. Copyright © 2015 John Wiley & Sons, Ltd.

  18. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  19. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  20. 10 CFR 26.127 - Procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., implement, and maintain written standard operating procedures for each assay performed for drug and specimen... facility shall develop, implement, and maintain written standard operating procedures for each test. The...; (2) Preparation of reagents, standards, and controls; (3) Calibration procedures; (4) Derivation of...

  1. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures

    PubMed Central

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel

    2016-01-01

    Aims This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. Methods and results From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose–area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). Conclusion The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. PMID:26589627

  2. Methodological Issues in Meta-Analyzing Standard Deviations: Comment on Bond and DePaulo (2008)

    ERIC Educational Resources Information Center

    Pigott, Therese D.; Wu, Meng-Jia

    2008-01-01

    In this comment on C. F. Bond and B. M. DePaulo, the authors raise methodological concerns about the approach used to analyze the data. The authors suggest further refinement of the procedures used, and they compare the approach taken by Bond and DePaulo with standard methods for meta-analysis. (Contains 1 table and 2 figures.)

  3. 76 FR 80261 - National Emission Standards for Hazardous Air Pollutants: Area Source Standards for Prepared...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... specifications and operating instructions, if available, or standard operating procedures must be developed by... manufacturer's specifications and operating instructions, if available, or standard operating procedures must... operating specifications or standard operating procedures developed by the prepared feeds manufacturer be...

  4. Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium

    PubMed Central

    Finak, Greg; Langweiler, Marc; Jaimes, Maria; Malek, Mehrnoush; Taghiyar, Jafar; Korin, Yael; Raddassi, Khadir; Devine, Lesley; Obermoser, Gerlinde; Pekalski, Marcin L.; Pontikos, Nikolas; Diaz, Alain; Heck, Susanne; Villanova, Federica; Terrazzini, Nadia; Kern, Florian; Qian, Yu; Stanton, Rick; Wang, Kui; Brandes, Aaron; Ramey, John; Aghaeepour, Nima; Mosmann, Tim; Scheuermann, Richard H.; Reed, Elaine; Palucka, Karolina; Pascual, Virginia; Blomberg, Bonnie B.; Nestle, Frank; Nussenblatt, Robert B.; Brinkman, Ryan Remy; Gottardo, Raphael; Maecker, Holden; McCoy, J Philip

    2016-01-01

    Standardization of immunophenotyping requires careful attention to reagents, sample handling, instrument setup, and data analysis, and is essential for successful cross-study and cross-center comparison of data. Experts developed five standardized, eight-color panels for identification of major immune cell subsets in peripheral blood. These were produced as pre-configured, lyophilized, reagents in 96-well plates. We present the results of a coordinated analysis of samples across nine laboratories using these panels with standardized operating procedures (SOPs). Manual gating was performed by each site and by a central site. Automated gating algorithms were developed and tested by the FlowCAP consortium. Centralized manual gating can reduce cross-center variability, and we sought to determine whether automated methods could streamline and standardize the analysis. Within-site variability was low in all experiments, but cross-site variability was lower when central analysis was performed in comparison with site-specific analysis. It was also lower for clearly defined cell subsets than those based on dim markers and for rare populations. Automated gating was able to match the performance of central manual analysis for all tested panels, exhibiting little to no bias and comparable variability. Standardized staining, data collection, and automated gating can increase power, reduce variability, and streamline analysis for immunophenotyping. PMID:26861911

  5. The use of a single multielement standard for trace analysis in biological materials by external beam PIXE

    NASA Astrophysics Data System (ADS)

    Biswas, S. K.; Khaliquzzaman, M.; Islam, M. M.; Khan, A. H.

    1984-04-01

    The validity of the use of a single multielement standard for mass calibration in thick-target external beam PIXE analysis of biological materials has been investigated. In this study, the NBS orchard leaf, SRM 1571, was used as the basic standard for trace element analysis in other biological materials. Using the present procedure, the concentrations of K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb and Sr were determined in several NBS reference materials such as bovine liver, spinach, rice flour, etc., generally in 20 μC irradiations with 2.0 MeV protons. The analytical results are compared with certified values of the NBS as well as with other measurements and the sources of errors are discussed.

  6. 40 CFR 63.1547 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standard operating procedures manual that describes in detail the procedures for inspection, maintenance...) The standard operating procedures manual for baghouses required by paragraph (a) of this section shall... specified in the standard operating procedures manual for inspections and routine maintenance shall, at a...

  7. 40 CFR 63.1547 - Monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard operating procedures manual that describes in detail the procedures for inspection, maintenance...) The standard operating procedures manual for baghouses required by paragraph (a) of this section shall... specified in the standard operating procedures manual for inspections and routine maintenance shall, at a...

  8. 76 FR 80314 - National Emission Standards for Hazardous Air Pollutants: Area Source Standards for Prepared...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-23

    ... operating instructions, if available, or standard operating procedures must be developed by the facility... operating instructions, if available, or standard operating procedures must be developed by the facility... standard operating procedures developed by the prepared feeds manufacturer be required as part of the...

  9. Multiple window spatial registration error of a gamma camera: 133Ba point source as a replacement of the NEMA procedure.

    PubMed

    Bergmann, Helmar; Minear, Gregory; Raith, Maria; Schaffarich, Peter M

    2008-12-09

    The accuracy of multiple window spatial resolution characterises the performance of a gamma camera for dual isotope imaging. In the present study we investigate an alternative method to the standard NEMA procedure for measuring this performance parameter. A long-lived 133Ba point source with gamma energies close to 67Ga and a single bore lead collimator were used to measure the multiple window spatial registration error. Calculation of the positions of the point source in the images used the NEMA algorithm. The results were validated against the values obtained by the standard NEMA procedure which uses a liquid 67Ga source with collimation. Of the source-collimator configurations under investigation an optimum collimator geometry, consisting of a 5 mm thick lead disk with a diameter of 46 mm and a 5 mm central bore, was selected. The multiple window spatial registration errors obtained by the 133Ba method showed excellent reproducibility (standard deviation < 0.07 mm). The values were compared with the results from the NEMA procedure obtained at the same locations and showed small differences with a correlation coefficient of 0.51 (p < 0.05). In addition, the 133Ba point source method proved to be much easier to use. A Bland-Altman analysis showed that the 133Ba and the 67Ga Method can be used interchangeably. The 133Ba point source method measures the multiple window spatial registration error with essentially the same accuracy as the NEMA-recommended procedure, but is easier and safer to use and has the potential to replace the current standard procedure.

  10. Two-Phase Extraction for Comprehensive Analysis of the Plant Metabolome by NMR.

    PubMed

    Schripsema, Jan; Dagnino, Denise

    2018-01-01

    Metabolomics is the area of research, which strives to obtain complete metabolic fingerprints, to detect differences between them, and to provide hypothesis to explain those differences [1]. But obtaining complete metabolic fingerprints is not an easy task. Metabolite extraction is a key step during this process, and much research has been devoted to finding the best solvent mixture to extract as much metabolites as possible.Here a procedure is described for analysis of both polar and apolar metabolites using a two-phase extraction system. D 2 O and CDCl 3 are the solvents of choice, and their major advantage is that, for the identification of the compounds, standard databases can be used because D 2 O and CDCl 3 are the solvents most commonly used for pure compound NMR spectra. The procedure enables the absolute quantification of components via the addition of suitable internal standards. The extracts are also suitable for further analysis with other systems like LC-MS or GC-MS.

  11. Sonication standard laboratory module

    DOEpatents

    Beugelsdijk, Tony; Hollen, Robert M.; Erkkila, Tracy H.; Bronisz, Lawrence E.; Roybal, Jeffrey E.; Clark, Michael Leon

    1999-01-01

    A standard laboratory module for automatically producing a solution of cominants from a soil sample. A sonication tip agitates a solution containing the soil sample in a beaker while a stepper motor rotates the sample. An aspirator tube, connected to a vacuum, draws the upper layer of solution from the beaker through a filter and into another beaker. This beaker can thereafter be removed for analysis of the solution. The standard laboratory module encloses an embedded controller providing process control, status feedback information and maintenance procedures for the equipment and operations within the standard laboratory module.

  12. 40 CFR 63.1547 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... according to, a standard operating procedures manual that describes in detail the procedures for inspection...) The standard operating procedures manual for baghouses required by paragraph (a) of this section must... specified in the standard operating procedures manual for inspections and routine maintenance must, at a...

  13. 40 CFR 63.1547 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... according to, a standard operating procedures manual that describes in detail the procedures for inspection...) The standard operating procedures manual for baghouses required by paragraph (a) of this section must... specified in the standard operating procedures manual for inspections and routine maintenance must, at a...

  14. 40 CFR 63.1547 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... according to, a standard operating procedures manual that describes in detail the procedures for inspection...) The standard operating procedures manual for baghouses required by paragraph (a) of this section must... specified in the standard operating procedures manual for inspections and routine maintenance must, at a...

  15. Analyzing lichen indicator data in the Forest Inventory and Analysis Program

    Treesearch

    Susan Will-Wolf

    2010-01-01

    Lichens are one of several forest health indicators sampled every year for a subset of plots on the permanent grid established by the Forest Inventory and Analysis (FIA) Program of the U.S. Department of Agriculture Forest Service. This report reviews analysis procedures for standard FIA lichen indicator data. Analyses of lichen data contribute to state, regional, and...

  16. Towards Implicational Scales for Use in Chicano English Composition. Papers in Southwest English 1: Research Techniques and Prospects.

    ERIC Educational Resources Information Center

    Hoffer, Bates

    Dialect analysis should follow the procedure for analysis of a new language: collection of a corpus of words, stories, and sentences and identifying structural features of phonology, morphology, syntax, and lexicon. Contrastive analysis between standard English and the native language is used and the ethnic dialect of English is described and…

  17. Retrospective review of Contura HDR breast cases to improve our standardized procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iftimia, Ileana, E-mail: Ileana.n.iftimia@lahey.org; Cirino, Eileen T.; Ladd, Ron

    2013-07-01

    To retrospectively review our first 20 Contura high dose rate breast cases to improve and refine our standardized procedure and checklists. We prepared in advance checklists for all steps, developed an in-house Excel spreadsheet for second checking the plan, and generated a procedure for efficient contouring and a set of optimization constraints to meet the dose volume histogram criteria. Templates were created in our treatment planning system for structures, isodose levels, optimization constraints, and plan report. This study reviews our first 20 high dose rate Contura breast treatment plans. We followed our standardized procedure for contouring, planning, and second checking.more » The established dose volume histogram criteria were successfully met for all plans. For the cases studied here, the balloon-skin and balloon-ribs distances ranged between 5 and 43 mm and 1 and 33 mm, respectively; air{sub s}eroma volume/PTV{sub E}val volume≤5.5% (allowed≤10%); asymmetry<1.2 mm (goal≤2 mm); PTV{sub E}val V90%≥97.6%; PTV{sub E}val V95%≥94.9%; skin max dose≤98%Rx; ribs max dose≤137%Rx; V150%≤29.8 cc; V200%≤7.8 cc; the total dwell time range was 225.4 to 401.9 seconds; and the second check agreement was within 3%. Based on this analysis, more appropriate ranges for the total dwell time and balloon diameter tolerance were found. Three major problems were encountered: balloon migration toward the skin for small balloon-to-skin distances, lumen obstruction, and length change for the flexible balloon. Solutions were found for these issues and our standardized procedure and checklists were updated accordingly. Based on our review of these cases, the use of checklists resulted in consistent results, indicating good coverage for the target without sacrificing the critical structures. This review helped us to refine our standardized procedure and update our checklists.« less

  18. Recommendations for a Standardized Program Management Office (PMO) Time Compliance Network Order (TCNO) Patching Process

    DTIC Science & Technology

    2007-03-01

    self -reporting. The interview process and resulting data analysis may be impacted by research bias since both were conducted by the same individual...the processes you employ? Answer: 97 MAJCOM CONTACTS RESPOSIBLE FOR GENERAL TCNO PROCEDURES SECTION 1: INTERVIEWEE INFO Question 1: Please...BASE-LEVEL NCC CONTACTS RESPOSIBLE FOR GENERAL TCNO PROCEDURES SECTION 1: INTERVIEWEE INFO Question 1: Please provide your general job description

  19. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING SOLID FOOD SAMPLES FOR ANALYSIS OF POLAR ORGANIC POLLUTANTS (SOP-5.28)

    EPA Science Inventory

    This SOP describes the extraction and preparation of a solid food sample for analysis of acidic persistent organic pollutants such as acid herbicides, pentachlorphenol, and 3,5,6-trichloro-2-phenol. It covers the extraction, concentration and derivatization of samples that are to...

  20. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING DUST AND SOIL SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.14)

    EPA Science Inventory

    This SOP summarizes the method for extracting and preparing a dust or soil sample for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.

  1. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING DERMAL WIPE SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.16)

    EPA Science Inventory

    The method for extracting and preparing a dermal (hand) wipe sample for analysis of neutral persistent organic pollutants is summarized in this SOP. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spectrometry.

  2. Review and Enhancement for Crash Analysis and Prediction: Phase 1 Evaluation of the Crash Studies and Analysis Standard Operating Procedures in Maryland

    DOT National Transportation Integrated Search

    2010-03-01

    Traffic safety has become one of the most critical issues facing transportation agencies across the nation. In 2006, about 43,000 people were killed, and another 290,000 were seriously injured in crashes on public roadways in the United States. Accor...

  3. A SAS Interface for Bayesian Analysis with WinBUGS

    ERIC Educational Resources Information Center

    Zhang, Zhiyong; McArdle, John J.; Wang, Lijuan; Hamagami, Fumiaki

    2008-01-01

    Bayesian methods are becoming very popular despite some practical difficulties in implementation. To assist in the practical application of Bayesian methods, we show how to implement Bayesian analysis with WinBUGS as part of a standard set of SAS routines. This implementation procedure is first illustrated by fitting a multiple regression model…

  4. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING LIQUID FOOD SAMPLES FOR ANALYSIS OF POLAR ORGANIC POLLUTANTS (SOP-5.29)

    EPA Science Inventory

    This SOP describes the extraction and preparation of a liquid food sample for analysis of acidic persistent organic pollutants such as acid herbicides, pentachlorphenol, and 3,5,6-trichloro-2-phenol. It covers the extraction, concentration and derivatization of samples that are t...

  5. A single extraction and HPLC procedure for simultaneous analysis of phytosterols, tocopherols and lutein in soybeans.

    PubMed

    Slavin, Margaret; Yu, Liangli Lucy

    2012-12-15

    A saponification/extraction procedure and high performance liquid chromatography (HPLC) analysis method were developed and validated for simultaneous analysis of phytosterols, tocopherols and lutein (a carotenoid) in soybeans. Separation was achieved on a phenyl column with a ternary, isocratic solvent system of acetonitrile, methanol and water (48:22.5:29.5, v/v/v). Evaporative light scattering detection (ELSD) was used to quantify β-sitosterol, stigmasterol, campesterol, and α-, δ- and γ-tocopherols, while lutein was quantified with visible light absorption at 450 nm. Peak identification was verified by retention times and spikes with external standards. Standard curves were constructed (R(2)>0.99) to allow for sample quantification. Recovery of the saponification and extraction was demonstrated via analysis of spiked samples. Also, the accuracy of results of four soybeans using the described saponification and HPLC analytical method was validated against existing methods. This method offers a more efficient alternative to individual methods for quantifying lutein, tocopherols and sterols in soybeans. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. 76 FR 47518 - Energy Conservation Program: Treatment of “Smart” Appliances in Energy Conservation Standards and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-05

    ... Conservation Program: Treatment of ``Smart'' Appliances in Energy Conservation Standards and Test Procedures... well as in test procedures used to demonstrate compliance with DOE's standards and qualification as an... development of energy conservation standards and test procedures for DOE's Appliance Standards Program and the...

  7. A SAS(®) macro implementation of a multiple comparison post hoc test for a Kruskal-Wallis analysis.

    PubMed

    Elliott, Alan C; Hynan, Linda S

    2011-04-01

    The Kruskal-Wallis (KW) nonparametric analysis of variance is often used instead of a standard one-way ANOVA when data are from a suspected non-normal population. The KW omnibus procedure tests for some differences between groups, but provides no specific post hoc pair wise comparisons. This paper provides a SAS(®) macro implementation of a multiple comparison test based on significant Kruskal-Wallis results from the SAS NPAR1WAY procedure. The implementation is designed for up to 20 groups at a user-specified alpha significance level. A Monte-Carlo simulation compared this nonparametric procedure to commonly used parametric multiple comparison tests. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  8. A modification of procedures for petrographic analysis of tertiary Indonesian coals

    NASA Astrophysics Data System (ADS)

    Moore, T. A.; Ferm, J. C.

    A study undertaken to characterize the Eocene coals from southeast Kalimantan has shown that standard preparation procedures fail to capture some basic petrographic properties of the coal. Modification of these procedures permits recognition of distinct plant parts and tissues embedded in finer grained matrix components. Plant parts and tissues can be classified on the basis of morphology and degree of degradation. The highest concentration and best preservation of plant parts and tissues occurs in banded coal and is lowest in the non-banded coal. Use of these procedures, which relates megascopic appearance to petrographic character, should allow more precise utilization of the coal.

  9. Evaluating flow cytometer performance with weighted quadratic least squares analysis of LED and multi-level bead data

    PubMed Central

    Parks, David R.; Khettabi, Faysal El; Chase, Eric; Hoffman, Robert A.; Perfetto, Stephen P.; Spidlen, Josef; Wood, James C.S.; Moore, Wayne A.; Brinkman, Ryan R.

    2017-01-01

    We developed a fully automated procedure for analyzing data from LED pulses and multi-level bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all of the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than for multi-level bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. PMID:28160404

  10. UMTRA Project water sampling and analysis plan, Durango, Colorado. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Durango, Colorado, are described in this water sampling and analysis plan. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine monitoring stations at the site. The ground water data are used to characterize the site ground water compliance strategies and to monitor contaminants of potential concern identified in the baseline risk assessment (DOE, 1995a). Regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from themore » US EPA regulations in 40 CFR Part 192 (1994) and EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site.« less

  11. Identifying fMRI Model Violations with Lagrange Multiplier Tests

    PubMed Central

    Cassidy, Ben; Long, Christopher J; Rae, Caroline; Solo, Victor

    2013-01-01

    The standard modeling framework in Functional Magnetic Resonance Imaging (fMRI) is predicated on assumptions of linearity, time invariance and stationarity. These assumptions are rarely checked because doing so requires specialised software, although failure to do so can lead to bias and mistaken inference. Identifying model violations is an essential but largely neglected step in standard fMRI data analysis. Using Lagrange Multiplier testing methods we have developed simple and efficient procedures for detecting model violations such as non-linearity, non-stationarity and validity of the common Double Gamma specification for hemodynamic response. These procedures are computationally cheap and can easily be added to a conventional analysis. The test statistic is calculated at each voxel and displayed as a spatial anomaly map which shows regions where a model is violated. The methodology is illustrated with a large number of real data examples. PMID:22542665

  12. 40 CFR 63.1549 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... recordkeeping required as part of the practices described in the standard operating procedures manual for... as part of the practices described in the standard operating procedures manual for baghouses required... procedures outlined in the standard operating procedures manual required by § 63.1544(a) were not followed...

  13. 40 CFR 63.1549 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... recordkeeping required as part of the practices described in the standard operating procedures manual for... as part of the practices described in the standard operating procedures manual for baghouses required... procedures outlined in the standard operating procedures manual required by § 63.1544(a) were not followed...

  14. 40 CFR 63.1549 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... recordkeeping required as part of the practices described in the standard operating procedures manual for... as part of the practices described in the standard operating procedures manual for baghouses required... procedures outlined in the standard operating procedures manual required by § 63.1544(a) were not followed...

  15. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  16. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  17. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  18. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  19. 40 CFR 75.32 - Determination of monitor data availability for standard missing data procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... availability for standard missing data procedures. 75.32 Section 75.32 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.32 Determination of monitor data availability for standard missing data procedures...

  20. Analysis of the effect of mobile phone base station antenna loading on localized SAR and its consequences for measurements.

    PubMed

    Hansson, Björn; Thors, Björn; Törnevik, Christer

    2011-12-01

    In this work, the effect of antenna element loading on the localized specific absorption rate (SAR) has been analyzed for base station antennas. The analysis was conducted in order to determine whether localized SAR measurements of large multi-element base station antennas can be conducted using standardized procedures and commercially available equipment. More specifically, it was investigated if the antenna shifting measurement procedure, specified in the European base station exposure assessment standard EN 50383, will produce accurate localized SAR results for base station antennas larger than the specified measurement phantom. The obtained results show that SAR accuracy is affected by the presence of lossy material within distances of one wavelength from the tested antennas as a consequence of coupling and redistribution of transmitted power among the antenna elements. It was also found that the existing standardized phantom is not optimal for SAR measurements of large base station antennas. A new methodology is instead proposed based on a larger, box-shaped, whole-body phantom. Copyright © 2011 Wiley Periodicals, Inc.

  1. Pulsed Dose Radiofrequency Before Ablation of Medial Branch of the Lumbar Dorsal Ramus for Zygapophyseal Joint Pain Reduces Post-procedural Pain.

    PubMed

    Arsanious, David; Gage, Emmanuel; Koning, Jonathon; Sarhan, Mazin; Chaiban, Gassan; Almualim, Mohammed; Atallah, Joseph

    2016-01-01

    One of the potential side effects with radiofrequency ablation (RFA) includes painful cutaneous dysesthesias and increased pain due to neuritis or neurogenic inflammation. This pain may require the prescription of opioids or non-opioid analgesics to control post-procedural pain and discomfort. The goal of this study is to compare post-procedural pain scores and post-procedural oral analgesic use in patients receiving continuous thermal radiofrequency ablation versus patients receiving pulsed dose radiofrequency immediately followed by continuous thermal radiofrequency ablation for zygopophaseal joint disease. This is a prospective, double-blinded, randomized, controlled trial. Patients who met all the inclusion criteria and were not subject to any of the exclusion criteria were required to have two positive diagnostic medial branch blocks prior to undergoing randomization, intervention, and analysis. University hospital. Eligible patients were randomized in a 1:1 ratio to either receive thermal radiofrequency ablation alone (standard group) or pulsed dose radiofrequency (PDRF) immediately followed by thermal radiofrequency ablation (investigational group), all of which were performed by a single Board Certified Pain Medicine physician. Post-procedural pain levels between the two groups were assessed using the numerical pain Scale (NPS), and patients were contacted by phone on post-procedural days 1 and 2 in the morning and afternoon regarding the amount of oral analgesic medications used in the first 48 hours following the procedure. Patients who received pulsed dose radiofrequency followed by continuous radiofrequency neurotomy reported statistically significantly lower post-procedural pain scores in the first 24 hours compared to patients who received thermal radiofrequency neurotomy alone. These patients also used less oral analgesic medication in the post-procedural period. These interventions were carried out by one board accredited pain physician at one center. The procedures were exclusively performed using one model of radiofrequency generator, at one setting for the PDRF and RFA. The difference in the number of levels of ablation was not considered in the analysis of the results. Treating patients with pulsed dose radiofrequency prior to continuous thermal radiofrequency ablation can provide patients with less post-procedural pain during the first 24 hours and also reduce analgesic requirements. Furthermore, the addition of PDRF to standard thermal RFA did not prolong the time of standard thermal radiofrequency ablation procedures, as it was performed during the typically allotted time for local anesthetic action. Low back pain, facet joint disease, medial branch block, Radiofrequency ablation, thermal radiofrequency, pulsed dose radiofrequency, PDRF, zygapophyseal joint.

  2. RE-PERG, a new procedure for electrophysiologic diagnosis of glaucoma that may improve PERG specificity.

    PubMed

    Mavilio, Alberto; Sisto, Dario; Ferreri, Paolo; Cardascia, Nicola; Alessio, Giovanni

    2017-01-01

    A significant variability of the second harmonic (2ndH) phase of steady-state pattern electroretinogram (SS-PERG) in intrasession retest has been recently described in glaucoma patients (GP), which has not been found in healthy subjects. To evaluate the reliability of phase variability in retest (a procedure called RE-PERG or REPERG) in the presence of cataract, which is known to affect standard PERG, we tested this procedure in GP, normal controls (NC), and cataract patients (CP). The procedure was performed on 50 GP, 35 NC, and 27 CP. All subjects were examined with RE-PERG and SS-PERG and also with spectral domain optical coherence tomography and standard automated perimetry. Standard deviation of phase and amplitude value of 2ndH were correlated by means of one-way analysis of variance and Pearson correlation, with the mean deviation and pattern standard deviation assessed by standard automated perimetry and retinal nerve fiber layer and the ganglion cell complex thickness assessed by spectral domain optical coherence tomography. Receiver operating characteristics were calculated in cohort populations with and without cataract. Standard deviation of phase of 2ndH was significantly higher in GP with respect to NC ( P <0.001) and CP ( P <0.001), and it correlated with retinal nerve fiber layer ( r =-0.5, P <0.001) and ganglion cell complex ( r =-0.6, P <0.001) defects in GP. Receiver operating characteristic evaluation showed higher specificity of RE-PERG (86.4%; area under the curve 0.93) with respect to SS-PERG (54.5%; area under the curve 0.68) in CP. RE-PERG may improve the specificity of SS-PERG in clinical practice in the discrimination of GP.

  3. Frontally eluted components procedure with thin layer chromatography as a mode of sample preparation for high performance liquid chromatography quantitation of acetaminophen in biological matrix.

    PubMed

    Klimek-Turek, A; Sikora, M; Rybicki, M; Dzido, T H

    2016-03-04

    A new concept of using thin-layer chromatography to sample preparation for the quantitative determination of solute/s followed by instrumental techniques is presented Thin-layer chromatography (TLC) is used to completely separate acetaminophen and its internal standard from other components (matrix) and to form a single spot/zone containing them at the solvent front position (after the final stage of the thin-layer chromatogram development). The location of the analytes and internal standard in the solvent front zone allows their easy extraction followed by quantitation by HPLC. The exctraction procedure of the solute/s and internal standard can proceed from whole solute frontal zone or its part without lowering in accuracy of quantitative analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Aligning "TextEvaluator"® Scores with the Accelerated Text Complexity Guidelines Specified in the Common Core State Standards. Research Report. ETS RR-15-21

    ERIC Educational Resources Information Center

    Sheehan, Kathleen M.

    2015-01-01

    The "TextEvaluator"® text analysis tool is a fully automated text complexity evaluation tool designed to help teachers, curriculum specialists, textbook publishers, and test developers select texts that are consistent with the text complexity guidelines specified in the Common Core State Standards.This paper documents the procedure used…

  5. Applied Polarography for Analysis of Ordnance Materials. Part 1. Determination and Monitoring for 1,2-Propyleneglycoldinitrate in Effluent Water by Single-Sweep Polarography

    DTIC Science & Technology

    1976-06-01

    ie irom Ott - Ae wastewatt:r. Data obtained by the NWC-developed method of analyds and field equipment ccupare favorably with data obtained by a vapor...5, curve &. A microaliquot of standard PIM solution is then added to the cell solution and the procedure is repeated. This is known as the standard

  6. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures.

    PubMed

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel

    2016-09-01

    This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose-area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  7. Effects of Reusing Gel Electrophoresis and Electrotransfer Buffers on Western Blotting.

    PubMed

    Heda, Ghanshyam D; Omotola, Oluwabukola B; Heda, Rajiv P; Avery, Jamie

    2016-09-01

    SDS-PAGE and Western blotting are 2 of the most commonly used biochemical methods for protein analysis. Proteins are electrophoretically separated based on their MWs by SDS-PAGE and then electrotransferred to a solid membrane surface for subsequent protein-specific analysis by immunoblotting, a procedure commonly known as Western blotting. Both of these procedures use a salt-based buffer, with the latter procedure consisting of methanol as an additive known for its toxicity. Previous reports present a contradictory view in favor or against reusing electrotransfer buffer, also known as Towbin's transfer buffer (TTB), with an aim to reduce the toxic waste. In this report, we present a detailed analysis of not only reusing TTB but also gel electrophoresis buffer (EB) on proteins of low to high MW range. Our results suggest that EB can be reused for at least 5 times without compromising the electrophoretic separation of mixture of proteins in an MW standard, BSA, and crude cell lysates. Additionally, reuse of EB did not affect the quality of subsequent Western blots. Successive reuse of TTB, on the other hand, diminished the signal of proteins of different MWs in a protein standard and a high MW membrane protein cystic fibrosis transmembrane-conductance regulator (CFTR) in Western blotting.

  8. Field guide for collecting and processing stream-water samples for the National Water-Quality Assessment Program

    USGS Publications Warehouse

    Shelton, Larry R.

    1994-01-01

    The U.S. Geological Survey's National Water-Quality Assessment program includes extensive data- collection efforts to assess the quality of the Nations's streams. These studies require analyses of stream samples for major ions, nutrients, sediments, and organic contaminants. For the information to be comparable among studies in different parts of the Nation, consistent procedures specifically designed to produce uncontaminated samples for trace analysis in the laboratory are critical. This field guide describes the standard procedures for collecting and processing samples for major ions, nutrients, organic contaminants, sediment, and field analyses of conductivity, pH, alkalinity, and dissolved oxygen. Samples are collected and processed using modified and newly designed equipment made of Teflon to avoid contamination, including nonmetallic samplers (D-77 and DH-81) and a Teflon sample splitter. Field solid-phase extraction procedures developed to process samples for organic constituent analyses produce an extracted sample with stabilized compounds for more accurate results. Improvements to standard operational procedures include the use of processing chambers and capsule filtering systems. A modified collecting and processing procedure for organic carbon is designed to avoid contamination from equipment cleaned with methanol. Quality assurance is maintained by strict collecting and processing procedures, replicate sampling, equipment blank samples, and a rigid cleaning procedure using detergent, hydrochloric acid, and methanol.

  9. SBKF Modeling and Analysis Plan: Buckling Analysis of Compression-Loaded Orthogrid and Isogrid Cylinders

    NASA Technical Reports Server (NTRS)

    Lovejoy, Andrew E.; Hilburger, Mark W.

    2013-01-01

    This document outlines a Modeling and Analysis Plan (MAP) to be followed by the SBKF analysts. It includes instructions on modeling and analysis formulation and execution, model verification and validation, identifying sources of error and uncertainty, and documentation. The goal of this MAP is to provide a standardized procedure that ensures uniformity and quality of the results produced by the project and corresponding documentation.

  10. Post flight analysis of NASA standard star trackers recovered from the solar maximum mission

    NASA Technical Reports Server (NTRS)

    Newman, P.

    1985-01-01

    The flight hardware returned after the Solar Maximum Mission Repair Mission was analyzed to determine the effects of 4 years in space. The NASA Standard Star Tracker would be a good candidate for such analysis because it is moderately complex and had a very elaborate calibration during the acceptance procedure. However, the recovery process extensively damaged the cathode of the image dissector detector making proper operation of the tracker and a comparison with preflight characteristics impossible. Otherwise, the tracker functioned nominally during testing.

  11. Shunting outcomes in posthemorrhagic hydrocephalus: results of a Hydrocephalus Clinical Research Network prospective cohort study.

    PubMed

    Wellons, John C; Shannon, Chevis N; Holubkov, Richard; Riva-Cambrin, Jay; Kulkarni, Abhaya V; Limbrick, David D; Whitehead, William; Browd, Samuel; Rozzelle, Curtis; Simon, Tamara D; Tamber, Mandeep S; Oakes, W Jerry; Drake, James; Luerssen, Thomas G; Kestle, John

    2017-07-01

    OBJECTIVE Previous Hydrocephalus Clinical Research Network (HCRN) retrospective studies have shown a 15% difference in rates of conversion to permanent shunts with the use of ventriculosubgaleal shunts (VSGSs) versus ventricular reservoirs (VRs) as temporization procedures in the treatment of hydrocephalus due to high-grade intraventricular hemorrhage (IVH) of prematurity. Further research in the same study line revealed a strong influence of center-specific decision-making on shunt outcomes. The primary goal of this prospective study was to standardize decision-making across centers to determine true procedural superiority, if any, of VSGS versus VR as a temporization procedure in high-grade IVH of prematurity. METHODS The HCRN conducted a prospective cohort study across 6 centers with an approximate 1.5- to 3-year accrual period (depending on center) followed by 6 months of follow-up. Infants with premature birth, who weighed less than 1500 g, had Grade 3 or 4 IVH of prematurity, and had more than 72 hours of life expectancy were included in the study. Based on a priori consensus, decisions were standardized regarding the timing of initial surgical treatment, upfront shunt versus temporization procedure (VR or VSGS), and when to convert a VR or VSGS to a permanent shunt. Physical examination assessment and surgical technique were also standardized. The primary outcome was the proportion of infants who underwent conversion to a permanent shunt. The major secondary outcomes of interest included infection and other complication rates. RESULTS One hundred forty-five premature infants were enrolled and met criteria for analysis. Using the standardized decision rubrics, 28 infants never reached the threshold for treatment, 11 initially received permanent shunts, 4 were initially treated with endoscopic third ventriculostomy (ETV), and 102 underwent a temporization procedure (36 with VSGSs and 66 with VRs). The 2 temporization cohorts were similar in terms of sex, race, IVH grade, head (orbitofrontal) circumference, and ventricular size at temporization. There were statistically significant differences noted between groups in gestational age, birth weight, and bilaterality of clot burden that were controlled for in post hoc analysis. By Kaplan-Meier analysis, the 180-day rates of conversion to permanent shunts were 63.5% for VSGS and 74.0% for VR (p = 0.36, log-rank test). The infection rate for VSGS was 14% (5/36) and for VR was 17% (11/66; p = 0.71). The overall compliance rate with the standardized decision rubrics was noted to be 90% for all surgeons. CONCLUSIONS A standardized protocol was instituted across all centers of the HCRN. Compliance was high. Choice of temporization techniques in premature infants with IVH does not appear to influence rates of conversion to permanent ventricular CSF diversion. Once management decisions and surgical techniques are standardized across HCRN sites, thus minimizing center effect, the observed difference in conversion rates between VSGSs and VRs is mitigated.

  12. In view of standardization: comparison and analysis of initial management of severely burned patients in Germany, Austria and Switzerland.

    PubMed

    Münzberg, Matthias; Ziegler, Benjamin; Fischer, Sebastian; Wölfl, Christoph Georg; Grützner, Paul Alfred; Kremer, Thomas; Kneser, Ulrich; Hirche, Christoph

    2015-02-01

    Initial treatment of severely injured patients in German speaking trauma centers follows precise sequences. Several guidelines and training courses ensure a constant quality in providing evidence-based treatment for these patients. Similar standards, algorithms and guidelines for the treatment of severely burned patients are lacking. This raises the question about the current standard of care for burn victims in German speaking burn centers. In order to achieve standardization, as a first step this study surveys principles of burn room organization and management in these burn centers. A questionnaire including 40 questions regarding burn room organization, personnel structure and qualification, infrastructural conditions and quality management was developed and sent to 21 level one burn centers in Germany, Austria and Switzerland. The rate of returned questionnaires was 81%. The analysis revealed varying personnel and infrastructural conditions in participating burn centers. Indications for admission to the burn room and admission procedures itself are different throughout surveyed hospitals. Individual standard operating procedure (SOP) for burn trauma admissions was available in most burn centers and nearly all participants register their burn trauma cases using an in-house burn register. The survey suggests a lack of standardization in personnel structure, infrastructure and treatment approach for the initial clinical care of severely burned patients in burn centers across the German speaking countries. Further evaluation of existing protocols and international standards in burn care is inevitable to develop standardized guidelines for burn care and to improve quality of care. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.

  13. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR PREPARATION OF STANDARD OPERATING PROCEDURES (G01)

    EPA Science Inventory

    The purpose of this SOP is to develop a consistent method and style for all Emory University/Harvard University/Johns Hopkins University standard operating procedures. SOPs are necessary to document all procedures, methods, and techniques used in the NHEXAS investigations. Deve...

  14. 77 FR 32645 - Revision of Performance Standards for State Medicaid Fraud Control Units

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-01

    ... Procedures A Unit establishes written policies and procedures for its operations and ensures that staff are familiar with, and adhere to, policies and procedures. To determine whether a Unit meets this standard, OIG... contain current policies and procedures, consistent with these performance standards, for the...

  15. 40 CFR 75.38 - Standard missing data procedures for Hg CEMS.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Standard missing data procedures for...) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.38 Standard missing data procedures for Hg CEMS. (a) Once 720 quality assured monitor operating hours of Hg...

  16. 75 FR 19296 - Energy Conservation Program: Test Procedures and Energy Conservation Standards for Residential...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ... Procedures and Energy Conservation Standards for Residential Furnaces and Boilers AGENCY: Office of Energy... supplemental notice of proposed rulemaking (SNOPR) to amend the test procedures for furnaces and boilers, and... Procedures for Residential Furnaces and Boilers'' or ``NOPM for Energy Conservation Standards for Residential...

  17. 78 FR 47047 - Proposed Policy for Discontinuance of Certain Instrument Approach Procedures

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... procedures. Localizer procedures. TACAN procedures. Standard Instrument Arrivals (STARs). Standard Instrument... Policy for Discontinuance of Certain Instrument Approach Procedures AGENCY: Federal Aviation... facilitates the introduction of area navigation (RNAV) instrument approach procedures over the past decade...

  18. Automated acid and base number determination of mineral-based lubricants by fourier transform infrared spectroscopy: commercial laboratory evaluation.

    PubMed

    Winterfield, Craig; van de Voort, F R

    2014-12-01

    The Fluid Life Corporation assessed and implemented Fourier transform infrared spectroscopy (FTIR)-based methods using American Society for Testing and Materials (ASTM)-like stoichiometric reactions for determination of acid and base number for in-service mineral-based oils. The basic protocols, quality control procedures, calibration, validation, and performance of these new quantitative methods are assessed. ASTM correspondence is attained using a mixed-mode calibration, using primary reference standards to anchor the calibration, supplemented by representative sample lubricants analyzed by ASTM procedures. A partial least squares calibration is devised by combining primary acid/base reference standards and representative samples, focusing on the main spectral stoichiometric response with chemometrics assisting in accounting for matrix variability. FTIR(AN/BN) methodology is precise, accurate, and free of most interference that affects ASTM D664 and D4739 results. Extensive side-by-side operational runs produced normally distributed differences with mean differences close to zero and standard deviations of 0.18 and 0.26 mg KOH/g, respectively. Statistically, the FTIR methods are a direct match to the ASTM methods, with superior performance in terms of analytical throughput, preparation time, and solvent use. FTIR(AN/BN) analysis is a viable, significant advance for in-service lubricant analysis, providing an economic means of trending samples instead of tedious and expensive conventional ASTM(AN/BN) procedures. © 2014 Society for Laboratory Automation and Screening.

  19. 40 CFR 63.543 - What are my standards for process vents?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... available. You must develop and follow standard operating procedures designed to minimize emissions of total... the manufacturer's recommended procedures, if available, and the standard operating procedures... 40 Protection of Environment 10 2013-07-01 2013-07-01 false What are my standards for process...

  20. 40 CFR 63.543 - What are my standards for process vents?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... available. You must develop and follow standard operating procedures designed to minimize emissions of total... the manufacturer's recommended procedures, if available, and the standard operating procedures... 40 Protection of Environment 10 2012-07-01 2012-07-01 false What are my standards for process...

  1. [A new HPLC procedure for cyclamate in food with pre-chromatographic derivatization].

    PubMed

    Schwedt, G; Hauck, M

    1988-08-01

    A high-pressure liquid chromatography (HPLC) procedure for the detection of cyclamate in liquid and solid samples is presented, which depends on oxidation and the reaction of cyclohexylamine with o-phthaldialdehyde to form a condensation product. The results of the HPLC analysis, using an RP-C 18 separation system with UV detection at 242 nm are reported. Contents, from 2 to 400 mg/l, can be detected in less than 2 h (HPLC analysis within 20 min) with relative standard deviations of 4%. Only for cucumber infusions were incomplete recoveries of 68% obtained.

  2. Surface Water Quality-Assurance Plan for the North Florida Program Office of the U.S. Geological Survey

    USGS Publications Warehouse

    Franklin, Marvin A.

    2000-01-01

    The U.S. Geological Survey, Water Resources Division, has a policy that requires each District office to prepare a Surface Water Quality-Assurance Plan. The plan for each District describes the policies and procedures that ensure high quality in the collection, processing, analysis, computer storage, and publication of surface-water data. The North Florida Program Office Surface Water Quality-Assurance Plan documents the standards, policies, and procedures used by the North Florida Program office for activities related to the collection, processing, storage, analysis, and publication of surface-water data.

  3. Transfer of knowledge in international cooperation: the Farmanguinhos - SMM case.

    PubMed

    Silva, Samuel Araujo Gomes da; Duarte, Roberto Gonzalez; Castro, José Márcio de

    2017-01-01

    To analyze the influence of four mechanisms of knowledge transfer (training, technical visits, expatriation, and standard operating procedures) on the different dimensions (potential and realized) of absorptive capacity in international technical cooperation. We examine the case of implementation of the Sociedade Moçambicana de Medicamentos. Data have been collected using semi-structured interviews (applied to 21 professionals of the Sociedade Moçambicana de Medicamentos, Farmanguinhos, FIOCRUZ, and Itamaraty) and official documents. The data of the interviews have been submitted to content analysis, using the software NVivo. Training and technical visits directly influenced the acquisition and, partly, the assimilation of knowledge. Expatriation contributed with the transformation of this knowledge from the development and refinement of operational routines. Finally, the definition of standard operating procedures allowed the Mozambican technicians to be the actors of the transformation of the knowledge previously acquired and assimilated and, at the same time, it laid the foundations for a future exploration of the knowledge. Training and technical visits mainly influence the potential absorptive capacity, while expatriation and standard operating procedures most directly affect the realized absorptive capacity.

  4. Interdisciplinary cognitive task analysis: a strategy to develop a comprehensive endoscopic retrograde cholangiopancreatography protocol for use in fellowship training.

    PubMed

    Canopy, Erin; Evans, Matt; Boehler, Margaret; Roberts, Nicole; Sanfey, Hilary; Mellinger, John

    2015-10-01

    Endoscopic retrograde cholangiopancreatography is a challenging procedure performed by surgeons and gastroenterologists. We employed cognitive task analysis to identify steps and decision points for this procedure. Standardized interviews were conducted with expert gastroenterologists (7) and surgeons (4) from 4 institutions. A procedural step and cognitive decision point protocol was created from audio-taped transcriptions and was refined by 5 additional surgeons. Conceptual elements, sequential actions, and decision points were iterated for 5 tasks: patient preparation, duodenal intubation, selective cannulation, imaging interpretation with related therapeutic intervention, and complication management. A total of 180 steps were identified. Gastroenterologists identified 34 steps not identified by surgeons, and surgeons identified 20 steps not identified by gastroenterologists. The findings suggest that for complex procedures performed by diverse practitioners, more experts may help delineate distinctive emphases differentiated by training background and type of practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. The use of analysis of variance procedures in biological studies

    USGS Publications Warehouse

    Williams, B.K.

    1987-01-01

    The analysis of variance (ANOVA) is widely used in biological studies, yet there remains considerable confusion among researchers about the interpretation of hypotheses being tested. Ambiguities arise when statistical designs are unbalanced, and in particular when not all combinations of design factors are represented in the data. This paper clarifies the relationship among hypothesis testing, statistical modelling and computing procedures in ANOVA for unbalanced data. A simple two-factor fixed effects design is used to illustrate three common parametrizations for ANOVA models, and some associations among these parametrizations are developed. Biologically meaningful hypotheses for main effects and interactions are given in terms of each parametrization, and procedures for testing the hypotheses are described. The standard statistical computing procedures in ANOVA are given along with their corresponding hypotheses. Throughout the development unbalanced designs are assumed and attention is given to problems that arise with missing cells.

  6. 40 CFR 63.545 - Standards for fugitive dust sources.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...

  7. 40 CFR 63.545 - Standards for fugitive dust sources.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... according to a standard operating procedures manual that describes in detail the measures that will be put... standard operating procedures manual shall be submitted to the Administrator or delegated authority for review and approval. (c) The controls specified in the standard operating procedures manual shall at a...

  8. 40 CFR 63.543 - What are my standards for process vents?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... develop and follow standard operating procedures designed to minimize emissions of total hydrocarbon for... manufacturer's recommended procedures, if available, and the standard operating procedures designed to minimize... 40 Protection of Environment 10 2014-07-01 2014-07-01 false What are my standards for process...

  9. Behavior analytic approaches to problem behavior in intellectual disabilities.

    PubMed

    Hagopian, Louis P; Gregory, Meagan K

    2016-03-01

    The purpose of the current review is to summarize recent behavior analytic research on problem behavior in individuals with intellectual disabilities. We have focused our review on studies published from 2013 to 2015, but also included earlier studies that were relevant. Behavior analytic research on problem behavior continues to focus on the use and refinement of functional behavioral assessment procedures and function-based interventions. During the review period, a number of studies reported on procedures aimed at making functional analysis procedures more time efficient. Behavioral interventions continue to evolve, and there were several larger scale clinical studies reporting on multiple individuals. There was increased attention on the part of behavioral researchers to develop statistical methods for analysis of within subject data and continued efforts to aggregate findings across studies through evaluative reviews and meta-analyses. Findings support continued utility of functional analysis for guiding individualized interventions and for classifying problem behavior. Modifications designed to make functional analysis more efficient relative to the standard method of functional analysis were reported; however, these require further validation. Larger scale studies on behavioral assessment and treatment procedures provided additional empirical support for effectiveness of these approaches and their sustainability outside controlled clinical settings.

  10. An expert system for the esthetic rating of bridges.

    DOT National Transportation Integrated Search

    1990-01-01

    The expert system presented should facilitate the in-depth analysis of bridge esthetics and encourage high standards for the appearance of bridges. The procedure described systematically evaluates features of a target bridge in relation to a similar ...

  11. Surface-Water Quality-Assurance Plan for the USGS Wisconsin Water Science Center

    USGS Publications Warehouse

    Garn, H.S.

    2007-01-01

    This surface-water quality-assurance plan documents the standards, policies, and procedures used by the Wisconsin Water Science Center of the U.S. Geological Survey, Water Resources Discipline, for activities related to the collection, processing, storage, analysis, management, and publication of surface-water data. The roles and responsibilities of Water Science Center personnel in following these policies and procedures including those related to safety and training are presented.

  12. Surface-water quality-assurance plan for the Wisconsin district of the U. S. Geological Survey, Water Resources Division

    USGS Publications Warehouse

    Garn, H.S.

    2002-01-01

    This surface-water quality-assurance plan documents the standards, policies, and procedures used by the Wisconsin District of the U.S. Geological Survey, Water Resources Division, for activities related to the collection, processing, storage, analysis, management, and publication of surface-water data. The roles and responsibilities of District personnel in following these policies and procedures including those related to safety and training are presented.

  13. Development of Procedures to Implement EOPS Cost Effectiveness Standards Model and Continued Evaluation of These Procedures by Selected Community Colleges during the 1974-75 Academic Year. EOPS Special Project 74-101.

    ERIC Educational Resources Information Center

    Aughinbaugh, Lorine A.; And Others

    Four products were developed during the second year of the Extended Opportunity Programs and Services (EOPS) cost effectiveness study for California community colleges. This project report presents: (1) a revised cost analysis form for state-level reporting of institutional program effectiveness data and per-student costs by EOPS program category…

  14. Music to reduce pain and distress in the pediatric emergency department: a randomized clinical trial.

    PubMed

    Hartling, Lisa; Newton, Amanda S; Liang, Yuanyuan; Jou, Hsing; Hewson, Krista; Klassen, Terry P; Curtis, Sarah

    2013-09-01

    Many medical procedures aimed at helping children cause them pain and distress, which can have long-lasting negative effects. Music is a form of distraction that may alleviate some of the pain and distress experienced by children while undergoing medical procedures. To compare music with standard care to manage pain and distress. Randomized clinical trial conducted in a pediatric emergency department with appropriate sequence generation and adequate allocation concealment from January 1, 2009, to March 31, 2010. Individuals assessing the primary outcome were blind to treatment allocation. A total of 42 children aged 3 to 11 years undergoing intravenous placement were included. Music (recordings selected by a music therapist via ambient speakers) vs standard care. The primary outcome was behavioral distress assessed blinded using the Observational Scale of Behavioral Distress-Revised. The secondary outcomes included child-reported pain, heart rate, parent and health care provider satisfaction, ease of performing the procedure, and parental anxiety. With or without controlling for potential confounders, we found no significant difference in the change in behavioral distress from before the procedure to immediately after the procedure. When children who had no distress during the procedure were removed from the analysis, there was a significantly less increase in distress for the music group (standard care group = 2.2 vs music group = 1.1, P < .05). Pain scores among children in the standard care group increased by 2 points, while they remained the same in the music group (P = .04); the difference was considered clinically important. The pattern of parent satisfaction with the management of children's pain was different between groups, although not statistically significant (P = .07). Health care providers reported that it was easier to perform the procedure for children in the music group (76% very easy) vs the standard care group (38% very easy) (P = .03). Health care providers were more satisfied with the intravenous placement in the music group (86% very satisfied) compared with the standard care group (48%) (P = .02). Music may have a positive impact on pain and distress for children undergoing intravenous placement. Benefits were also observed for the parents and health care providers. clinicaltrials.gov Identifier: NCT00761033.

  15. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, Hg, and flow rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Standard missing data procedures for... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.33 Standard missing data procedures for SO2, NOX, Hg, and flow rate. (a) Following initial...

  16. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, and flow rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Standard missing data procedures for... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.33 Standard missing data procedures for SO2, NOX, and flow rate. (a) Following initial certification...

  17. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, and flow rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Standard missing data procedures for... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.33 Standard missing data procedures for SO2, NOX, and flow rate. (a) Following initial certification...

  18. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, and flow rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Standard missing data procedures for... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.33 Standard missing data procedures for SO2, NOX, and flow rate. (a) Following initial certification...

  19. 40 CFR 75.33 - Standard missing data procedures for SO2, NOX, and flow rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Standard missing data procedures for... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Missing Data Substitution Procedures § 75.33 Standard missing data procedures for SO2, NOX, and flow rate. (a) Following initial certification...

  20. A Delphi Consensus of the Crucial Steps in Gastric Bypass and Sleeve Gastrectomy Procedures in the Netherlands.

    PubMed

    Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N

    2018-04-09

    Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.

  1. Nonlinear filtering properties of detrended fluctuation analysis

    NASA Astrophysics Data System (ADS)

    Kiyono, Ken; Tsujimoto, Yutaka

    2016-11-01

    Detrended fluctuation analysis (DFA) has been widely used for quantifying long-range correlation and fractal scaling behavior. In DFA, to avoid spurious detection of scaling behavior caused by a nonstationary trend embedded in the analyzed time series, a detrending procedure using piecewise least-squares fitting has been applied. However, it has been pointed out that the nonlinear filtering properties involved with detrending may induce instabilities in the scaling exponent estimation. To understand this issue, we investigate the adverse effects of the DFA detrending procedure on the statistical estimation. We show that the detrending procedure using piecewise least-squares fitting results in the nonuniformly weighted estimation of the root-mean-square deviation and that this property could induce an increase in the estimation error. In addition, for comparison purposes, we investigate the performance of a centered detrending moving average analysis with a linear detrending filter and sliding window DFA and show that these methods have better performance than the standard DFA.

  2. Risk analysis and its link with standards of the World Organisation for Animal Health.

    PubMed

    Sugiura, K; Murray, N

    2011-04-01

    Among the agreements included in the treaty that created the World Trade Organization (WTO) in January 1995 is the Agreement on the Application of Sanitary and Phytosanitary Measures (SPS Agreement) that sets out the basic rules for food safety and animal and plant health standards. The SPS Agreement designates the World Organisation for Animal Health (OIE) as the organisation responsible for developing international standards for animal health and zoonoses. The SPS Agreement requires that the sanitary measures that WTO members apply should be based on science and encourages them to either apply measures based on the OIE standards or, if they choose to adopt a higher level of protection than that provided by these standards, apply measures based on a science-based risk assessment. The OIE also provides a procedural framework for risk analysis for its Member Countries to use. Despite the inevitable challenges that arise in carrying out a risk analysis of the international trade in animals and animal products, the OIE risk analysis framework provides a structured approach that facilitates the identification, assessment, management and communication of these risks.

  3. Task Analysis for Health Occupations. Cluster: Nursing. Occupation: Geriatric Aide. Education for Employment Task Lists.

    ERIC Educational Resources Information Center

    Lake County Area Vocational Center, Grayslake, IL.

    This task analysis for nursing education provides performance standards, steps to be followed, knowledge required, attitudes to be developed, safety procedures, and equipment and supplies needed for 13 tasks performed by geriatric aides in the duty area of performing diagnostic measures and for 30 tasks in the duty area of providing therapeutic…

  4. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING DUST AND SOIL SAMPLES FOR ANALYSIS OF POLAR PERSISTENT ORGANIC POLLUTANTS (SOP-5.15)

    EPA Science Inventory

    The method for extracting and preparing a dust or soil sample for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the extraction, concentration, and derivatization of samples that are to be analyzed by gas chromatography/mass spectrometry.

  5. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING URINE SAMPLES FOR ANALYSIS OF HYDROXY POLYCYCLIC AROMATIC HYDROCARBONS, PENTACHLOROPHENOL AND 2,4-D (SOP-5.21)

    EPA Science Inventory

    The method for extracting and preparing urine samples for analysis of hydroxy-polycyclic aromatic hydrocarbons, pentachlorophenol and 2,4-D is summarized in this SOP. It covers the extraction, concentration and methylation of samples that are to be analyzed by gas chromatography/...

  6. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING AIR SAMPLES FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.12)

    EPA Science Inventory

    The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...

  7. CTEPP STANDARD OPERATING PROCEDURE FOR EXTRACTING AND PREPARING SURFACE WIPE FOR ANALYSIS OF NEUTRAL PERSISTENT ORGANIC POLLUTANTS (SOP-5.17)

    EPA Science Inventory

    This SOP summarizes the method for extracting and preparing a hard floor surface wipe or food preparation surface wipe sample for analysis of neutral persistent organic. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass spect...

  8. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF 2-PHASE MULTISORBENT SAMPLERS FOR VOCS (BCO-L-31.0)

    EPA Science Inventory

    The purpose of this SOP is to describe the methodology for the analysis of certain trace volatile organic compounds (VOCs) in air that are captured on two-phase carbon-based multisorbent tubes packed with Carbotrap (graphitized carbon blacks) and Carbosieve S-III (a carbon molecu...

  9. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF 3-PHASE MULTISORBENT SAMPLERS FOR VOCS (BCO-L-22.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methodology for the analysis of certain trace volatile organic compounds (VOCs) in air that are captured on carbon-based multisorbent tubes packed with Carbotrap C, Carbotrap (graphitized carbon blacks), and Carbosieve S-III (a carbon mo...

  10. 45 CFR 164.308 - Administrative safeguards.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...)(i) Standard: Security management process. Implement policies and procedures to prevent, detect... this subpart for the entity. (3)(i) Standard: Workforce security. Implement policies and procedures to...) Standard: Information access management. Implement policies and procedures for authorizing access to...

  11. 45 CFR 164.308 - Administrative safeguards.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...)(i) Standard: Security management process. Implement policies and procedures to prevent, detect... this subpart for the entity. (3)(i) Standard: Workforce security. Implement policies and procedures to...) Standard: Information access management. Implement policies and procedures for authorizing access to...

  12. Software Development Standard Processes (SDSP)

    NASA Technical Reports Server (NTRS)

    Lavin, Milton L.; Wang, James J.; Morillo, Ronald; Mayer, John T.; Jamshidian, Barzia; Shimizu, Kenneth J.; Wilkinson, Belinda M.; Hihn, Jairus M.; Borgen, Rosana B.; Meyer, Kenneth N.; hide

    2011-01-01

    A JPL-created set of standard processes is to be used throughout the lifecycle of software development. These SDSPs cover a range of activities, from management and engineering activities, to assurance and support activities. These processes must be applied to software tasks per a prescribed set of procedures. JPL s Software Quality Improvement Project is currently working at the behest of the JPL Software Process Owner to ensure that all applicable software tasks follow these procedures. The SDSPs are captured as a set of 22 standards in JPL s software process domain. They were developed in-house at JPL by a number of Subject Matter Experts (SMEs) residing primarily within the Engineering and Science Directorate, but also from the Business Operations Directorate and Safety and Mission Success Directorate. These practices include not only currently performed best practices, but also JPL-desired future practices in key thrust areas like software architecting and software reuse analysis. Additionally, these SDSPs conform to many standards and requirements to which JPL projects are beholden.

  13. PubMed Central

    DAMONTI, A.; MORELLI, P.; MUSSI, M.; PATREGNANI, C.; GARAGIOLA, E.; FOGLIA, E.; PAGANI, R.; CARMINATI, R.; PORAZZI, E.

    2015-01-01

    Summary Introduction. The objective of this paper is the comparison between two different technologies used for the removal of a uterine myoma, a frequent benign tumor: the standard technology currently used, laparoscopy, and an innovative one, colpoceliotomy. It was considered relevant to evaluate the real and the potential effects of the two technologies implementation and, in addition, the consequences that the introduction or exclusion of the innovative technology would have for both the National Health System (NHS) and the entire community. Methods. The comparison between these two different technologies, the standard and the innovative one, was conducted using a Health Technology Assessment (HTA). In particular, in order to analyse their differences, a multi-dimensional approach was considered: effectiveness, costs and budget impact analysis data were collected, applying different instruments, such as the Activity Based Costing methodology (ABC), the Cost-Effectiveness Analysis (CEA) and the Budget Impact Analysis (BIA). Organisational, equity and social impact were also evaluated. Results. The results showed that the introduction of colpoceliotomy would provide significant economic savings to the Regional and National Health Service; in particular, a saving of € 453.27 for each surgical procedure. Discussion. The introduction of the innovative technology, colpoceliotomy, could be considered a valuable tool; one offering many advantages related to less invasiveness and a shorter surgical procedure than the standard technology currently used (laparoscopy). PMID:26900330

  14. Insulation Cork Boards-Environmental Life Cycle Assessment of an Organic Construction Material.

    PubMed

    Silvestre, José D; Pargana, Nuno; de Brito, Jorge; Pinheiro, Manuel D; Durão, Vera

    2016-05-20

    Envelope insulation is a relevant technical solution to cut energy consumption and reduce environmental impacts in buildings. Insulation Cork Boards (ICB) are a natural thermal insulation material whose production promotes the recycling of agricultural waste. The aim of this paper is to determine and evaluate the environmental impacts of the production, use, and end-of-life processing of ICB. A "cradle-to-cradle" environmental Life Cycle Assessment (LCA) was performed according to International LCA standards and the European standards on the environmental evaluation of buildings. These results were based on site-specific data and resulted from a consistent methodology, fully described in the paper for each life cycle stage: Cork oak tree growth, ICB production, and end-of-life processing-modeling of the carbon flows ( i.e. , uptakes and emissions), including sensitivity analysis of this procedure; at the production stage-the modeling of energy processes and a sensitivity analysis of the allocation procedures; during building operation-the expected service life of ICB; an analysis concerning the need to consider the thermal diffusivity of ICB in the comparison of the performance of insulation materials. This paper presents the up-to-date "cradle-to-cradle" environmental performance of ICB for the environmental categories and life-cycle stages defined in European standards.

  15. Insulation Cork Boards—Environmental Life Cycle Assessment of an Organic Construction Material

    PubMed Central

    Silvestre, José D.; Pargana, Nuno; de Brito, Jorge; Pinheiro, Manuel D.; Durão, Vera

    2016-01-01

    Envelope insulation is a relevant technical solution to cut energy consumption and reduce environmental impacts in buildings. Insulation Cork Boards (ICB) are a natural thermal insulation material whose production promotes the recycling of agricultural waste. The aim of this paper is to determine and evaluate the environmental impacts of the production, use, and end-of-life processing of ICB. A “cradle-to-cradle” environmental Life Cycle Assessment (LCA) was performed according to International LCA standards and the European standards on the environmental evaluation of buildings. These results were based on site-specific data and resulted from a consistent methodology, fully described in the paper for each life cycle stage: Cork oak tree growth, ICB production, and end-of-life processing-modeling of the carbon flows (i.e., uptakes and emissions), including sensitivity analysis of this procedure; at the production stage—the modeling of energy processes and a sensitivity analysis of the allocation procedures; during building operation—the expected service life of ICB; an analysis concerning the need to consider the thermal diffusivity of ICB in the comparison of the performance of insulation materials. This paper presents the up-to-date “cradle-to-cradle” environmental performance of ICB for the environmental categories and life-cycle stages defined in European standards. PMID:28773516

  16. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    PubMed

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  17. 78 FR 44112 - California State Motor Vehicle Pollution Control Standards; Urban Buses; Request for Waiver of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-23

    ... Board (CARB) its request for a waiver of preemption for emission standards and related test procedures... standards and test procedures for heavy-duty urban bus engines and vehicles. The 2000 rulemaking included... to emission standards and test procedures resulting from these five sets of amendments were codified...

  18. 76 FR 56126 - Energy Conservation Program: Treatment of “Smart” Appliances in Energy Conservation Standards and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-12

    ...'s energy conservation standards, as well as in test procedures used to demonstrate compliance with...'' appliances in the development of DOE's energy conservation standards, as well as in test procedures used to... Conservation Program: Treatment of ``Smart'' Appliances in Energy Conservation Standards and Test Procedures...

  19. A new integrated instrumental approach to autonomic nervous system assessment.

    PubMed

    Corazza, I; Barletta, G; Guaraldi, P; Cecere, A; Calandra-Buonaura, G; Altini, E; Zannoli, R; Cortelli, P

    2014-11-01

    The autonomic nervous system (ANS) regulates involuntary body functions and is commonly evaluated by measuring reflex responses of systolic and diastolic blood pressure (BP) and heart rate (HR) to physiological and pharmacological stimuli. However, BP and HR values may not sufficient be to explain specific ANS events and other parameters like the electrocardiogram (ECG), BP waves, the respiratory rate and the electroencephalogram (EEG) are mandatory. Although ANS behaviour and its response to stimuli are well-known, their clinical evaluation is often based on individual medical training and experience. As a result, ANS laboratories have been customized, making it impossible to standardize procedures and share results with colleagues. The aim of our study was to build a powerful versatile instrument easy-to-use in clinical practice to standardize procedures and allow a cross-analysis of all the parameters of interest for ANS evaluation. The new ANScovery System developed by neurologists and technicians is a two-step device: (1) integrating physiological information from different already existing commercial modules, making it possible to cross-analyse, store and share data; (2) standardizing procedures by an innovative tutor monitor able to guide the patient throughout ANS testing. The daily use of the new ANScovery System in clinical practice has proved it is a versatile easy to use instrument. Standardization of the manoeuvres and step-by-step guidance throughout the procedure avoid repetitions and allow intra and inter-patient data comparison. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. The use of standard operating procedures in day case anterior cruciate ligament reconstruction.

    PubMed

    Khan, T; Jackson, W F; Beard, D J; Marfin, A; Ahmad, M; Spacie, R; Jones, R; Howes, S; Barker, K; Price, A J

    2012-08-01

    The current rate of day-case anterior cruciate ligament reconstruction (ACLR) in the UK remains low. Although specialised care pathways with standard operating procedures (SOPs) have been effective in reducing length of stay following some surgical procedures, this has not been previously reported for ACLR. We evaluate the effectiveness of SOPs for establishing day-case ACLR in a specialist unit. Fifty patients undergoing ACLR between May and September 2010 were studied prospectively ("study group"). SOPs were designed for pre-operative assessment, anaesthesia, surgical procedure, mobilisation and discharge. We evaluated length of stay, readmission rates, patient satisfaction and compliance to SOPs. A retrospective analysis of 50 patients who underwent ACLR prior to implementation of the day-case pathway was performed ("standard practice group"). Eighty percent of patients in the study group were discharged on the day of surgery (mean length of stay=5.3h) compared to 16% in the standard practice group (mean length of stay=21.6h). This difference was statistically significant (p<0.05, Mann-Whitney U test). All patients were satisfied with the day case pathway. Ninety-two percent of the study group were discharged on the day of surgery when all SOPs were followed and 46% where they were not. High rates of day-case ACLR with excellent patient satisfaction can be achieved with the use of a specialised patient pathway with SOPs. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Novel approaches to analysis by flow injection gradient titration.

    PubMed

    Wójtowicz, Marzena; Kozak, Joanna; Kościelniak, Paweł

    2007-09-26

    Two novel procedures for flow injection gradient titration with the use of a single stock standard solution are proposed. In the multi-point single-line (MP-SL) method the calibration graph is constructed on the basis of a set of standard solutions, which are generated in a standard reservoir and subsequently injected into the titrant. According to the single-point multi-line (SP-ML) procedure the standard solution and a sample are injected into the titrant stream from four loops of different capacities, hence four calibration graphs are able to be constructed and the analytical result is calculated on the basis of a generalized slope of these graphs. Both approaches have been tested on the example of spectrophotometric acid-base titration of hydrochloric and acetic acids with using bromothymol blue and phenolphthalein as indicators, respectively, and sodium hydroxide as a titrant. Under optimized experimental conditions the analytical results of precision less than 1.8 and 2.5% (RSD) and of accuracy less than 3.0 and 5.4% (relative error (RE)) were obtained for MP-SL and SP-ML procedures, respectively, in ranges of 0.0031-0.0631 mol L(-1) for samples of hydrochloric acid and of 0.1680-1.7600 mol L(-1) for samples of acetic acid. The feasibility of both methods was illustrated by applying them to the total acidity determination in vinegar samples with precision lower than 0.5 and 2.9% (RSD) for MP-SL and SP-ML procedures, respectively.

  2. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  3. JSC Design and Procedural Standards, JSC-STD-8080

    NASA Technical Reports Server (NTRS)

    Punch, Danny T.

    2011-01-01

    This document provides design and procedural requirements appropriate for inclusion in specifications for any human spaceflight program, project, spacecraft, system, or end item. The term "spacecraft" as used in the standards includes launch vehicles, orbital vehicles, non-terrestrial surface vehicles, and modules. The standards are developed and maintained as directed by Johnson Space Center (JSC) Policy Directive JPD 8080.2, JSC Design and Procedural Standards for Human Space Flight Equipment. The Design and Procedural Standards contained in this manual represent human spacecraft design and operational knowledge applicable to a wide range of spaceflight activities. These standards are imposed on JSC human spaceflight equipment through JPD 8080.2. Designers shall comply with all design standards applicable to their design effort.

  4. [Scientific monitoring of the visitation procedure in inpatient rehabilitation centres of the German statutory pension insurance fund--the "Visit II" Project].

    PubMed

    Neuderth, S; Saupe-Heide, M; Brückner, U; Gross, B; Wenderoth, N; Vogel, H

    2012-06-01

    Visitation procedures are an established method of external quality assurance. They have been conducted for many years in the German statutory pension insurance's medical rehabilitation centres and have continuously been refined and standardized. The overall goal of the visitation procedure implemented by the German statutory pension fund is to ensure compliance with defined quality standards as well as information exchange and counselling of rehabilitation centres. In the context of advancing the visitation procedure in the German statutory pension funds' medical rehabilitation centres, the "Visit II" Project was initiated to evaluate the perspectives and expectations of the various professional groups involved in the visitations and to modify the materials used during visitations (documentation form and manual). Evaluation data from the rehabilitation centres visited in 2008 were gathered using both written surveys (utilization analysis) and telephone-based interviews with administration managers and chief physicians. The utilization analysis procedure was evaluated with regard to its methodological quality. In addition, the pension insurance physicians in charge of patient allocation during socio-medical assessment were surveyed with regard to potential needs for revision of the visitation procedure. Data collection was complemented by expert panels with auditors. Interviews with users as part of the formative evaluation of the visitation procedure showed positive results regarding acceptance and applicability of the visitations as well as of the utilization analysis procedures. Various suggestions were made with regard to modification and revision of the visitation materials, that could be implemented in many cases. Documentation forms were supplemented by current scientifically-based topics in rehabilitation (e. g., vocationally oriented measures), whereas items with minor relevance were skipped. The manual (for somatic indications) was thoroughly revised. The transparent presentation of visitation processes and visitation criteria has proven to be a useful basis for strengthening the cooperation between the statutory pension insurance funds and the rehabilitation centres. Moreover, it is a helpful tool for the systematic and continuous advancement of this complex method by including all parties involved. © Georg Thieme Verlag KG Stuttgart · New York.

  5. DNA origami-based standards for quantitative fluorescence microscopy.

    PubMed

    Schmied, Jürgen J; Raab, Mario; Forthmann, Carsten; Pibiri, Enrico; Wünsch, Bettina; Dammeyer, Thorben; Tinnefeld, Philip

    2014-01-01

    Validating and testing a fluorescence microscope or a microscopy method requires defined samples that can be used as standards. DNA origami is a new tool that provides a framework to place defined numbers of small molecules such as fluorescent dyes or proteins in a programmed geometry with nanometer precision. The flexibility and versatility in the design of DNA origami microscopy standards makes them ideally suited for the broad variety of emerging super-resolution microscopy methods. As DNA origami structures are durable and portable, they can become a universally available specimen to check the everyday functionality of a microscope. The standards are immobilized on a glass slide, and they can be imaged without further preparation and can be stored for up to 6 months. We describe a detailed protocol for the design, production and use of DNA origami microscopy standards, and we introduce a DNA origami rectangle, bundles and a nanopillar as fluorescent nanoscopic rulers. The protocol provides procedures for the design and realization of fluorescent marks on DNA origami structures, their production and purification, quality control, handling, immobilization, measurement and data analysis. The procedure can be completed in 1-2 d.

  6. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  7. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  8. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  9. 21 CFR 58.81 - Standard operating procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Testing Facilities Operation § 58.81 Standard operating procedures. (a) A testing facility shall have standard operating procedures in writing setting... following: (1) Animal room preparation. (2) Animal care. (3) Receipt, identification, storage, handling...

  10. Two-step estimation in ratio-of-mediator-probability weighted causal mediation analysis.

    PubMed

    Bein, Edward; Deutsch, Jonah; Hong, Guanglei; Porter, Kristin E; Qin, Xu; Yang, Cheng

    2018-04-15

    This study investigates appropriate estimation of estimator variability in the context of causal mediation analysis that employs propensity score-based weighting. Such an analysis decomposes the total effect of a treatment on the outcome into an indirect effect transmitted through a focal mediator and a direct effect bypassing the mediator. Ratio-of-mediator-probability weighting estimates these causal effects by adjusting for the confounding impact of a large number of pretreatment covariates through propensity score-based weighting. In step 1, a propensity score model is estimated. In step 2, the causal effects of interest are estimated using weights derived from the prior step's regression coefficient estimates. Statistical inferences obtained from this 2-step estimation procedure are potentially problematic if the estimated standard errors of the causal effect estimates do not reflect the sampling uncertainty in the estimation of the weights. This study extends to ratio-of-mediator-probability weighting analysis a solution to the 2-step estimation problem by stacking the score functions from both steps. We derive the asymptotic variance-covariance matrix for the indirect effect and direct effect 2-step estimators, provide simulation results, and illustrate with an application study. Our simulation results indicate that the sampling uncertainty in the estimated weights should not be ignored. The standard error estimation using the stacking procedure offers a viable alternative to bootstrap standard error estimation. We discuss broad implications of this approach for causal analysis involving propensity score-based weighting. Copyright © 2018 John Wiley & Sons, Ltd.

  11. Applications of remote sensing, volume 3

    NASA Technical Reports Server (NTRS)

    Landgrebe, D. A. (Principal Investigator)

    1977-01-01

    The author has identified the following significant results. Of the four change detection techniques (post classification comparison, delta data, spectral/temporal, and layered spectral temporal), the post classification comparison was selected for further development. This was based upon test performances of the four change detection method, straightforwardness of the procedures, and the output products desired. A standardized modified, supervised classification procedure for analyzing the Texas coastal zone data was compiled. This procedure was developed in order that all quadrangles in the study are would be classified using similar analysis techniques to allow for meaningful comparisons and evaluations of the classifications.

  12. 40 CFR 1065.940 - Emission calculations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROLS ENGINE-TESTING PROCEDURES Field Testing and Portable Emission Measurement Systems § 1065.940...-specific emissions for each test interval using any applicable information and instructions in the standard.... Determine this fixed value by engineering analysis. [75 FR 68467, Nov. 8, 2010] ...

  13. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  14. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  15. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  16. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  17. 7 CFR 610.23 - State Technical Committee meetings.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Technical Committee member. (b) NRCS will establish and maintain national standard operating procedures... standard operating procedures will outline items such as: The best practice approach to establishing... standard operating procedures established under paragraph (b) of this section, the State Conservationist...

  18. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    PubMed Central

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beavin, P. Jr.

    A rapid direct dilution procedure for the estimation of soluble zirconium and a fusion procedure for the determination of total zirconium (soluble and insoluble forms) in cream base concentrates prepared from antiperspirant aerosols are described. The direct dilution procedure involves extraction of soluble zirconium with HCl (55 + 45). The filtered extract is reacted with alizarin red S to form a stable colored complex which is measured spectrophotometrically. The fusion procedure involves ashing the aerosol concentrate followed by fusion of the ash with potassium pyrosulfate to form an acid-soluble melt. Zirconium is precipitated from solution as the hydroxide and washedmore » to eliminate interfering ions, particularly sulfate. After redissolving in HCl (55 + 45) and reacting with alizarin red S, total zirconium is measured. Zirconyl chloride octahydrate, assayed gravimetrically by hydroxide precipitation and conversion to the oxide, is used as the zirconium reference standard. Concentration range of zirconium measured was 200 to 500 ..mu..g/100 ml. Recoveries of standard zirconium added to commercial aerosols labeled to contain aluminum and zirconyl hydroxychlorides ranged from 97 to 101 percent by the fusion procedure. Analysis of these aerosols by direct dilution gave generally slightly lower results than by fusion.« less

  20. Site 765: Sedimentology

    USGS Publications Warehouse

    ,

    1990-01-01

    Various techniques were used to decipher the sedimentation history of Site 765, including Markov chain analysis of facies transitions, XRD analysis of clay and other minerals, and multivariate analysis of smear-slide data, in addition to the standard descriptive procedures employed by the shipboard sedimentologist. This chapter presents brief summaries of methodology and major findings of these three techniques, a summary of the sedimentation history, and a discussion of trends in sedimentation through time.

  1. Evaluating flow cytometer performance with weighted quadratic least squares analysis of LED and multi-level bead data.

    PubMed

    Parks, David R; El Khettabi, Faysal; Chase, Eric; Hoffman, Robert A; Perfetto, Stephen P; Spidlen, Josef; Wood, James C S; Moore, Wayne A; Brinkman, Ryan R

    2017-03-01

    We developed a fully automated procedure for analyzing data from LED pulses and multilevel bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than that from multilevel bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  2. [Outpatient breast surgery].

    PubMed

    Cappel, J; Lüders, K

    1980-01-24

    Indication, standard operative procedure and technique of ambulant diagnostic mammary surgery is shown in detail from 15 years of experience. In respect of reducing costs intraoperative quick-frozen sections and in case of malignancy radical mastectomy immediately after biopsy during continuous general anesthesia is important. By retrospective analysis we could prove that operative results in treatment of benign breast tumors by out-patient surgery or otherwise for in-patients do not differ. According to an inquiry patients preferred by 60% out-patient procedure.

  3. Radioimmunoassay determinations of p-hydroxyphenformin and of apparent phenformin in human plasma or serum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alkalay, D.; Khemani, L.; Bartlett, M.F.

    1978-01-01

    Sensitive radioimmunoassay procedures are described for measuring p-hydroxyphenformin and apparent phenformin in human plasma or serum. The p-hydroxyphenformin procedure, which requires advance phenformin analysis, offers excellent accuracy. The determinations of apparent phenformin are influenced by the phenformin and p-hydroxyphenformin contents of the samples. Over a period of four months, the methods showed a precision associated with relative standard deviations of 12% for apparent phenformin and 13% for p-hydroxyphenformin.

  4. 21 CFR 680.1 - Allergenic Products.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Mold manufacturers shall maintain written standard operating procedures, developed by a qualified... representative species of mold subject to the standard operating procedures. The tests shall be performed at each manufacturing step during and subsequent to harvest, as specified in the standard operating procedures. Before...

  5. 21 CFR 680.1 - Allergenic Products.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Mold manufacturers shall maintain written standard operating procedures, developed by a qualified... representative species of mold subject to the standard operating procedures. The tests shall be performed at each manufacturing step during and subsequent to harvest, as specified in the standard operating procedures. Before...

  6. 21 CFR 680.1 - Allergenic Products.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Mold manufacturers shall maintain written standard operating procedures, developed by a qualified... representative species of mold subject to the standard operating procedures. The tests shall be performed at each manufacturing step during and subsequent to harvest, as specified in the standard operating procedures. Before...

  7. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) You must prepare, and at all times operate according to, a standard operating procedures manual that...) You must submit the standard operating procedures manual for baghouses required by paragraph (a) of... that you specify in the standard operating procedures manual for inspections and routine maintenance...

  8. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) You must prepare, and at all times operate according to, a standard operating procedures manual that...) You must submit the standard operating procedures manual for baghouses required by paragraph (a) of... that you specify in the standard operating procedures manual for inspections and routine maintenance...

  9. 21 CFR 680.1 - Allergenic Products.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Mold manufacturers shall maintain written standard operating procedures, developed by a qualified... representative species of mold subject to the standard operating procedures. The tests shall be performed at each manufacturing step during and subsequent to harvest, as specified in the standard operating procedures. Before...

  10. 40 CFR 63.548 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) You must prepare, and at all times operate according to, a standard operating procedures manual that...) You must submit the standard operating procedures manual for baghouses required by paragraph (a) of... that you specify in the standard operating procedures manual for inspections and routine maintenance...

  11. Building Energy Simulation Test for Existing Homes (BESTEST-EX) (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Judkoff, R.; Neymark, J.; Polly, B.

    2011-12-01

    This presentation discusses the goals of NREL Analysis Accuracy R&D; BESTEST-EX goals; what BESTEST-EX is; how it works; 'Building Physics' cases; 'Building Physics' reference results; 'utility bill calibration' cases; limitations and potential future work. Goals of NREL Analysis Accuracy R&D are: (1) Provide industry with the tools and technical information needed to improve the accuracy and consistency of analysis methods; (2) Reduce the risks associated with purchasing, financing, and selling energy efficiency upgrades; and (3) Enhance software and input collection methods considering impacts on accuracy, cost, and time of energy assessments. BESTEST-EX Goals are: (1) Test software predictions of retrofitmore » energy savings in existing homes; (2) Ensure building physics calculations and utility bill calibration procedures perform up to a minimum standard; and (3) Quantify impact of uncertainties in input audit data and occupant behavior. BESTEST-EX is a repeatable procedure that tests how well audit software predictions compare to the current state of the art in building energy simulation. There is no direct truth standard. However, reference software have been subjected to validation testing, including comparisons with empirical data.« less

  12. Effect of Flexible Duty Hour Policies on Length of Stay for Complex Intra-Abdominal Operations: A Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) Trial Analysis.

    PubMed

    Stulberg, Jonah J; Pavey, Emily S; Cohen, Mark E; Ko, Clifford Y; Hoyt, David B; Bilimoria, Karl Y

    2017-02-01

    Changes to resident duty hour policies in the Flexibility in Duty Hour Requirements for Surgical Trainees (FIRST) trial could impact hospitalized patients' length of stay (LOS) by altering care coordination. Length of stay can also serve as a reflection of all complications, particularly those not captured in the FIRST trial (eg pneumothorax from central line). Programs were randomized to either maintaining current ACGME duty hour policies (Standard arm) or more flexible policies waiving rules on maximum shift lengths and time off between shifts (Flexible arm). Our objective was to determine whether flexibility in resident duty hours affected LOS in patients undergoing high-risk surgical operations. Patients were identified who underwent hepatectomy, pancreatectomy, laparoscopic colectomy, open colectomy, or ventral hernia repair (2014-2015 academic year) at 154 hospitals participating in the FIRST trial. Two procedure-stratified evaluations of LOS were undertaken: multivariable negative binomial regression analysis on LOS and a multivariable logistic regression analysis on the likelihood of a prolonged LOS (>75 th percentile). Before any adjustments, there was no statistically significant difference in overall mean LOS between study arms (Flexible Policy: mean [SD] LOS 6.03 [5.78] days vs Standard Policy: mean LOS 6.21 [5.82] days; p = 0.74). In adjusted analyses, there was no statistically significant difference in LOS between study arms overall (incidence rate ratio for Flexible vs Standard: 0.982; 95% CI, 0.939-1.026; p = 0.41) or for any individual procedures. In addition, there was no statistically significant difference in the proportion of patients with prolonged LOS between study arms overall (Flexible vs Standard: odds ratio = 1.028; 95% CI, 0.871-1.212) or for any individual procedures. Duty hour flexibility had no statistically significant effect on LOS in patients undergoing complex intra-abdominal operations. Copyright © 2016 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Cost minimisation analysis of using acellular dermal matrix (Strattice™) for breast reconstruction compared with standard techniques.

    PubMed

    Johnson, R K; Wright, C K; Gandhi, A; Charny, M C; Barr, L

    2013-03-01

    We performed a cost analysis (using UK 2011/12 NHS tariffs as a proxy for cost) comparing immediate breast reconstruction using the new one-stage technique of acellular dermal matrix (Strattice™) with implant versus the standard alternative techniques of tissue expander (TE)/implant as a two-stage procedure and latissimus dorsi (LD) flap reconstruction. Clinical report data were collected for operative time, length of stay, outpatient procedures, and number of elective and emergency admissions in our first consecutive 24 patients undergoing one-stage Strattice reconstruction. Total cost to the NHS based on tariff, assuming top-up payments to cover Strattice acquisition costs, was assessed and compared to the two historical control groups matched on key variables. Eleven patients having unilateral Strattice reconstruction were compared to 10 having TE/implant reconstruction and 10 having LD flap and implant reconstruction. Thirteen patients having bilateral Strattice reconstruction were compared to 12 having bilateral TE/implant reconstruction. Total costs were: unilateral Strattice, £3685; unilateral TE, £4985; unilateral LD and implant, £6321; bilateral TE, £5478; and bilateral Strattice, £6771. The cost analysis shows a financial advantage of using acellular dermal matrix (Strattice) in unilateral breast reconstruction versus alternative procedures. The reimbursement system in England (Payment by Results) is based on disease-related groups similar to that of many countries across Europe and tariffs are based on reported hospital costs, making this analysis of relevance in other countries. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. "Heidelberg standard examination" and "Heidelberg standard procedures" - Development of faculty-wide standards for physical examination techniques and clinical procedures in undergraduate medical education.

    PubMed

    Nikendei, C; Ganschow, P; Groener, J B; Huwendiek, S; Köchel, A; Köhl-Hackert, N; Pjontek, R; Rodrian, J; Scheibe, F; Stadler, A-K; Steiner, T; Stiepak, J; Tabatabai, J; Utz, A; Kadmon, M

    2016-01-01

    The competent physical examination of patients and the safe and professional implementation of clinical procedures constitute essential components of medical practice in nearly all areas of medicine. The central objective of the projects "Heidelberg standard examination" and "Heidelberg standard procedures", which were initiated by students, was to establish uniform interdisciplinary standards for physical examination and clinical procedures, and to distribute them in coordination with all clinical disciplines at the Heidelberg University Hospital. The presented project report illuminates the background of the initiative and its methodological implementation. Moreover, it describes the multimedia documentation in the form of pocketbooks and a multimedia internet-based platform, as well as the integration into the curriculum. The project presentation aims to provide orientation and action guidelines to facilitate similar processes in other faculties.

  15. Methodological Issues of Sample Collection and Analysis of Exhaled Breath

    EPA Science Inventory

    Recommended standardized procedures have been developed for measurement of exhaled lower respiratory nitric oxide (NO) and nasal NO. It would be desirable to develop similar guidelines for the sampling of exhaled breath related to other compounds. For such systemic volatile o...

  16. 21 CFR 120.6 - Sanitation standard operating procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Section 120.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General..., fuel, pesticides, cleaning compounds, sanitizing agents, condensate, and other chemical, physical, and...

  17. 21 CFR 120.6 - Sanitation standard operating procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Section 120.6 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION HAZARD ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS General..., fuel, pesticides, cleaning compounds, sanitizing agents, condensate, and other chemical, physical, and...

  18. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  19. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  20. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  1. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  2. 7 CFR 58.930 - Official test methods.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...

  3. NHEXAS PHASE I REGION 5 STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It provide...

  4. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE FOR COLLECTION, STORAGE, AND SHIPMENT OF BLOOD SAMPLES FOR METAL, PESTICIDE, PAH, VOC, AND LIPID ANALYSIS (F11)

    EPA Science Inventory

    The purpose of this SOP is to describe collection, storage, and shipment requirements of blood samples for metal, pesticide, polynuclear aromatic hydrocarbons (PAHs), volatile organic compound (VOC), and lipid analysis. Seven samples were taken from a single puncture: two 3-mL t...

  5. NHEXAS PHASE I MARYLAND STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOCS IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  6. United States Navy Contracting Officer Warranting Process

    DTIC Science & Technology

    2011-03-01

    by 30% or more of the respondents: Contract Law , Cost Analysis, Market Research, Contract Source Selection, Simplified Acquisition Procedures, and...that the majority of AOs found the following course at least somewhat important: Contract Law , Cost Analysis, Market Research, Contract 52 Source...the budget and appropriation cycle 4. Ethics and conduct standards 5. Basic contract laws and regulations 6. Socio-economic requirements in

  7. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...

  8. Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application.

    PubMed

    Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran

    2015-01-01

    Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced "gold-standard" for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system's measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures.

  9. Gas chromatography/trace analysis of derivatized azelaic acid as a stability marker.

    PubMed

    Alzweiri, Muhammed; Tarawneh, Ruba; Khanfar, Mohammad A

    2013-10-01

    Azelaic acid, a naturally occurring saturated dicarboxylic acid, is found in many topical formulations for its various medical benefits or as a byproduct of the oxidative decomposition of unsaturated fatty acids. The poor volatility of azelaic acid hinders its applicability in GC analysis. Therefore, azelaic acid was derivatized by methylation and silylation procedures to enhance its volatility for GC analysis. Accordingly, dimethyl azelate (DMA) and di(trimethylsilyl) azelate were synthesized and characterized by GC-MS. Subsequently, a GC with flame ionization detection method was developed and validated to analyze trace amounts of azelaic acid in some marketed skin creams. Unlike DMA, di(trimethylsilyl) azelate was chemically unstable and degraded within few hours. Nonane was used as a stable internal standard. Variability due to derivatization and extraction was controlled by a standard addition procedure. DMA analysis was linear in a wide concentration range (100 ng/mL to 100 mg/mL). Moreover, the method was accurate (96.4-103.4%) and precise with inter- and intraday variability <2.0% and LOQ and LOD of 100 and 10 ng/mL, respectively. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Alterations to Functional Analysis Methodology to Clarify the Functions of Low Rate, High Intensity Problem Behavior

    PubMed Central

    Davis, Barbara J; Schmidt, Jonathan; Bowman, Lynn G; Boelter, Eric W

    2012-01-01

    Current research provides few suggestions for modifications to functional analysis procedures to accommodate low rate, high intensity problem behavior. This study examined the results of the extended duration functional analysis procedures of Kahng, Abt, and Schonbachler (2001) with six children admitted to an inpatient hospital for the treatment of severe problem behavior. Results of initial functional analyses (Iwata, Dorsey, Slifer, Bauman, & Richman, 1982/1994) were inconclusive for all children because of low levels of responding. The altered functional analyses, which changed multiple variables including the duration of the functional analysis (i.e., 6 or 7 hrs), yielded clear behavioral functions for all six participants. These results add additional support for the utility of an altered analysis of low rate, high intensity problem behavior when standard functional analyses do not yield differentiated results. PMID:23326628

  11. Alterations to functional analysis methodology to clarify the functions of low rate, high intensity problem behavior.

    PubMed

    Davis, Barbara J; Kahng, Sungwoo; Schmidt, Jonathan; Bowman, Lynn G; Boelter, Eric W

    2012-01-01

    Current research provides few suggestions for modifications to functional analysis procedures to accommodate low rate, high intensity problem behavior. This study examined the results of the extended duration functional analysis procedures of Kahng, Abt, and Schonbachler (2001) with six children admitted to an inpatient hospital for the treatment of severe problem behavior. Results of initial functional analyses (Iwata, Dorsey, Slifer, Bauman, & Richman, 1982/1994) were inconclusive for all children because of low levels of responding. The altered functional analyses, which changed multiple variables including the duration of the functional analysis (i.e., 6 or 7 hrs), yielded clear behavioral functions for all six participants. These results add additional support for the utility of an altered analysis of low rate, high intensity problem behavior when standard functional analyses do not yield differentiated results.

  12. Modified application of HS-SPME for quality evaluation of essential oil plant materials.

    PubMed

    Dawidowicz, Andrzej L; Szewczyk, Joanna; Dybowski, Michal P

    2016-01-01

    The main limitation in the standard application of head space analysis employing solid phase microextraction (HS-SPME) for the evaluation of plants as sources of essential oils (EOs) are different quantitative relations of EO components from those obtained by direct analysis of EO which was got in the steam distillation (SD) process from the same plant (EO/SD). The results presented in the paper for thyme, mint, sage, basil, savory, and marjoram prove that the quantitative relations of EO components established by HS-SPME procedure and direct analysis of EO/SD are similar when the plant material in the HS-SPME process is replaced by its suspension in oil of the same physicochemical character as that of SPME fiber coating. The observed differences in the thyme EO composition estimated by both procedures are insignificant (F(exp)

  13. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  14. 40 CFR 63.550 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... recordkeeping required as part of the practices described in the standard operating procedures manual for... part of the practices described in the standard operating procedures manual for baghouses required... period, including an explanation of the periods when the procedures outlined in the standard operating...

  15. 40 CFR 63.550 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... recordkeeping required as part of the practices described in the standard operating procedures manual for... part of the practices described in the standard operating procedures manual for baghouses required... period, including an explanation of the periods when the procedures outlined in the standard operating...

  16. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  17. 40 CFR 136.7 - Quality assurance and quality control.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... quality control elements, where applicable, into the laboratory's documented standard operating procedure... quality control elements must be clearly documented in the written standard operating procedure for each... Methods contains QA/QC procedures in the Part 1000 section of the Standard Methods Compendium. The...

  18. 49 CFR 383.131 - Test procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... provide standardized scoring sheets for the skills tests, as well as standardized driving instructions for... 49 Transportation 5 2010-10-01 2010-10-01 false Test procedures. 383.131 Section 383.131... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.131 Test procedures. (a) Driver information manuals...

  19. Preliminary analysis techniques for ring and stringer stiffened cylindrical shells

    NASA Technical Reports Server (NTRS)

    Graham, J.

    1993-01-01

    This report outlines methods of analysis for the buckling of thin-walled circumferentially and longitudinally stiffened cylindrical shells. Methods of analysis for the various failure modes are presented in one cohesive package. Where applicable, more than one method of analysis for a failure mode is presented along with standard practices. The results of this report are primarily intended for use in launch vehicle design in the elastic range. A Microsoft Excel worksheet with accompanying macros has been developed to automate the analysis procedures.

  20. Analysis of low levels of rare earths by radiochemical neutron activation analysis

    USGS Publications Warehouse

    Wandless, G.A.; Morgan, J.W.

    1985-01-01

    A procedure for the radiochemical neutron-activation analysis for the rare earth elements (REE) involves the separation of the REE as a group by rapid ion-exchange methods and determination of yields by reactivation or by energy dispersive X-ray fluorescence (EDXRF) spectrometry. The U. S. Geological Survey (USGS) standard rocks, BCR-1 and AGV-1, were analyzed to determine the precision and accuracy of the method. We found that the precision was ??5-10% on the basis of replicate analysis and that, in general the accuracy was within ??5% of accepted values for most REE. Data for USGS standard rocks BIR-1 (Icelandic basalt) and DNC-1 (North Carolina diabase) are also presented. ?? 1985 Akade??miai Kiado??.

  1. Preparation of radioactive iodinated cholylhistamine for use in the radioimmunoassay of cholic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weinberg, P.B.; Kinkade, J.M. Jr.; Collins, D.C.

    1977-11-01

    A major handicap in the development of simple and accurate radioimmunoassay procedures for bile acids has been the lack of a radioactive standard of high specific activity. To provide such a compound, we first synthesized cholylhistamine using the carbodiimide reaction. The hypothesized structure was confirmed by elemental analysis, thin-layer chromatography, infrared and mass spectral analysis. The cholylhistamine was then iodinated with /sup 125/I, using the choloramine-T method. The /sup 125/I-cholylhistamine was bound by antisera raised against a cholic acid-bovine serum albumin conjugate. This procedure should prove useful in preparing radioactive conjugates for all of the bile acids.

  2. Analyzing AQP Data to Improve Electronic Flight Bag (EFB) Operations and Training

    NASA Technical Reports Server (NTRS)

    Seamster, Thomas L.; Kanki, Barbara

    2010-01-01

    Key points include: Initiate data collection and analysis early in the implementation process. Use data to identify procedural and training refinements. Use a de-identified system to analyze longitudinal data. Use longitudinal I/E data to improve their standardization. Identify above average pilots and crews and use their performance to specify best practices. Analyze below average crew performance data to isolate problems with the training, evaluator standardization and pilot proficiency.

  3. Improving the safety and quality of nursing care through standardized operating procedures in Bosnia and Herzegovina.

    PubMed

    Ausserhofer, Dietmar; Rakic, Severin; Novo, Ahmed; Dropic, Emira; Fisekovic, Eldin; Sredic, Ana; Van Malderen, Greet

    2016-06-01

    We explored how selected 'positive deviant' healthcare facilities in Bosnia and Herzegovina approach the continuous development, adaptation, implementation, monitoring and evaluation of nursing-related standard operating procedures. Standardized nursing care is internationally recognized as a critical element of safe, high-quality health care; yet very little research has examined one of its key instruments: nursing-related standard operating procedures. Despite variability in Bosnia and Herzegovina's healthcare and nursing care quality, we assumed that some healthcare facilities would have developed effective strategies to elevate nursing quality and safety through the use of standard operating procedures. Guided by the 'positive deviance' approach, we used a multiple-case study design to examine a criterion sample of four facilities (two primary healthcare centres and two hospitals), collecting data via focus groups and individual interviews. In each studied facility, certification/accreditation processes were crucial to the initiation of continuous development, adaptation, implementation, monitoring and evaluation of nursing-related SOPs. In one hospital and one primary healthcare centre, nurses working in advanced roles (i.e. quality coordinators) were responsible for developing and implementing nursing-related standard operating procedures. Across the four studied institutions, we identified a consistent approach to standard operating procedures-related processes. The certification/accreditation process is enabling necessary changes in institutions' organizational cultures, empowering nurses to take on advanced roles in improving the safety and quality of nursing care. Standardizing nursing procedures is key to improve the safety and quality of nursing care. Nursing and Health Policy are needed in Bosnia and Herzegovina to establish a functioning institutional framework, including regulatory bodies, educational systems for developing nurses' capacities or the inclusion of nursing-related standard operating procedures in certification/accreditation standards. © 2016 International Council of Nurses.

  4. Interlaboratory comparison for the determination of the soluble fraction of metals in welding fume samples.

    PubMed

    Berlinger, Balazs; Harper, Martin

    2018-02-01

    There is interest in the bioaccessible metal components of aerosols, but this has been minimally studied because standardized sampling and analytical methods have not yet been developed. An interlaboratory study (ILS) has been carried out to evaluate a method for determining the water-soluble component of realistic welding fume (WF) air samples. Replicate samples were generated in the laboratory and distributed to participating laboratories to be analyzed according to a standardized procedure. Within-laboratory precision of replicate sample analysis (repeatability) was very good. Reproducibility between laboratories was not as good, but within limits of acceptability for the analysis of typical aerosol samples. These results can be used to support the development of a standardized test method.

  5. Drafting guidelines for occupational exposure to chemicals: the Dutch experience with the assessment of reproductive risks.

    PubMed

    Stijkel, A; van Eijndhoven, J C; Bal, R

    1996-12-01

    The Dutch procedure for standard setting for occupational exposure to chemicals, just like the European Union (EU) procedure, is characterized by an organizational separation between considerations of health on the one side, and of technology, economics, and policy on the other side. Health considerations form the basis for numerical guidelines. These guidelines are next combined with technical-economical considerations. Standards are then proposed, and are finally set by the Ministry of Social Affairs and Employment. An analysis of this procedure might be of relevance to the US, where other procedures are used and criticized. In this article we focus on the first stage of the standard-setting procedure. In this stage, the Dutch Expert Committee on Occupational Standards (DECOS) drafts a criteria document in which a health-based guideline is proposed. The drafting is based on a set of starting points for assessing toxicity. We raise the questions, "Does DECOS limit itself only to health considerations? And if not, what are the consequences of such a situation?" We discuss DECOS' starting points and analyze the relationships between those starting points, and then explore eight criteria documents where DECOS was considering reproductive risks as a possible critical effect. For various reasons, it will be concluded that the starting points leave much interpretative space, and that this space is widened further by the manner in which DECOS utilizes it. This is especially true in situations involving sex-specific risks and uncertainties in knowledge. Consequently, even at the first stage, where health considerations alone are intended to play a role, there is much room for other than health-related factors to influence decision making, although it is unavoidable that some interpretative space will remain. We argue that separating the various types of consideration should not be abandoned. Rather, through adjustments in the starting points and aspects of the procedure, clarity should be guaranteed about the way the interpretative space is being employed.

  6. A scaling procedure for the response of an isolated system with high modal overlap factor

    NASA Astrophysics Data System (ADS)

    De Rosa, S.; Franco, F.

    2008-10-01

    The paper deals with a numerical approach that reduces some physical sizes of the solution domain to compute the dynamic response of an isolated system: it has been named Asymptotical Scaled Modal Analysis (ASMA). The proposed numerical procedure alters the input data needed to obtain the classic modal responses to increase the frequency band of validity of the discrete or continuous coordinates model through the definition of a proper scaling coefficient. It is demonstrated that the computational cost remains acceptable while the frequency range of analysis increases. Moreover, with reference to the flexural vibrations of a rectangular plate, the paper discusses the ASMA vs. the statistical energy analysis and the energy distribution approach. Some insights are also given about the limits of the scaling coefficient. Finally it is shown that the linear dynamic response, predicted with the scaling procedure, has the same quality and characteristics of the statistical energy analysis, but it can be useful when the system cannot be solved appropriately by the standard Statistical Energy Analysis (SEA).

  7. A simulator study for the development and evaluation of operating procedures on a supersonic cruise research transport to minimize airport-community noise

    NASA Technical Reports Server (NTRS)

    Grantham, W. D.; Smith, P. M.; Deal, P. L.

    1980-01-01

    Piloted-simulator studies were conducted to determine takeoff and landing operating procedures for a supersonic cruise research transport concept that result in predicted noise levels which meet current Federal Aviation Administration (FAA) certification standards. With the use of standard FAA noise certification test procedures, the subject simulated aircraft did not meet the FAA traded-noise-level standards during takeoff and landing. However, with the use of advanced procedures, this aircraft meets the traded-noise-level standards for flight crews with average skills. The advanced takeoff procedures developed involved violating some of the current Federal Aviation Regulations (FAR), but it was not necessary to violate any FAR noise-test conditions during landing approach. Noise contours were also determined for some of the simulated takeoffs and landings in order to indicate the noise-reduction advantages of using operational procedures other than standard.

  8. 42 CFR 431.708 - Procedures for applying standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Programs for Licensing Nursing Home Administrators § 431.708 Procedures for applying standards. The agency... 42 Public Health 4 2010-10-01 2010-10-01 false Procedures for applying standards. 431.708 Section 431.708 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN...

  9. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  10. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  11. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  12. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  13. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  14. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  15. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  16. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  17. 40 CFR 792.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standardized. (b) The written standard operating procedures required under § 792.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  18. 21 CFR 58.63 - Maintenance and calibration of equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... standardized. (b) The written standard operating procedures required under § 58.81(b)(11) shall set forth in... maintenance operations were routine and followed the written standard operating procedures. Written records... operating procedures shall designate the person responsible for the performance of each operation. (c...

  19. 77 FR 49056 - Categorical Exclusion From Further Environmental Review for Standard Terminal Arrival Route...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-15

    ... public of its environmental review of two standard terminal arrival route (STAR) procedures and two... STAR procedures and the two proposed SID procedures to determine the level of environmental review... STAR procedures identified as GIBBZ (RNAV) STAR and DOCCS STAR and the proposed SID procedures...

  20. Exosome-like vesicles in uterine aspirates: a comparison of ultracentrifugation-based isolation protocols.

    PubMed

    Campoy, Irene; Lanau, Lucia; Altadill, Tatiana; Sequeiros, Tamara; Cabrera, Silvia; Cubo-Abert, Montserrat; Pérez-Benavente, Assumpción; Garcia, Angel; Borrós, Salvador; Santamaria, Anna; Ponce, Jordi; Matias-Guiu, Xavier; Reventós, Jaume; Gil-Moreno, Antonio; Rigau, Marina; Colas, Eva

    2016-06-18

    Uterine aspirates are used in the diagnostic process of endometrial disorders, yet further applications could emerge if its complex milieu was simplified. Exosome-like vesicles isolated from uterine aspirates could become an attractive source of biomarkers, but there is a need to standardize isolation protocols. The objective of the study was to determine whether exosome-like vesicles exist in the fluid fraction of uterine aspirates and to compare protocols for their isolation, characterization, and analysis. We collected uterine aspirates from 39 pre-menopausal women suffering from benign gynecological diseases. The fluid fraction of 27 of those aspirates were pooled and split into equal volumes to evaluate three differential centrifugation-based procedures: (1) a standard protocol, (2) a filtration protocol, and (3) a sucrose cushion protocol. Characterization of isolated vesicles was assessed by electron microscopy, nanoparticle tracking analysis and immunoblot. Specifically for RNA material, we evaluate the effect of sonication and RNase A treatment at different steps of the protocol. We finally confirmed the efficiency of the selected methods in non-pooled samples. All protocols were useful to isolate exosome-like vesicles. However, the Standard procedure was the best performing protocol to isolate exosome-like vesicles from uterine aspirates: nanoparticle tracking analysis revealed a higher concentration of vesicles with a mode of 135 ± 5 nm, and immunoblot showed a higher expression of exosome-related markers (CD9, CD63, and CD81) thus verifying an enrichment in this type of vesicles. RNA contained in exosome-like vesicles was successfully extracted with no sonication treatment and exogenous nucleic acids digestion with RNaseA, allowing the analysis of the specific inner cargo by Real-Time qPCR. We confirmed the existence of exosome-like vesicles in the fluid fraction of uterine aspirates. They were successfully isolated by differential centrifugation giving sufficient proteomic and transcriptomic material for further analyses. The Standard protocol was the best performing procedure since the other two tested protocols did not ameliorate neither yield nor purity of exosome-like vesicles. This study contributes to establishing the basis for future comparative studies to foster the field of biomarker research in gynecology.

  1. Standardization of the capillary electrophoresis procedures Capillarys® CDT and Minicap® CDT in comparison to the IFCC reference measurement procedure.

    PubMed

    Schellenberg, François; Humeau, Camille

    2017-06-01

    CDT is at present the most relevant routinely available biological marker of alcohol use and is widely used for screening and monitoring of patients. The lack of standardization leads to specific reference intervals for each procedure. The IFCC working group devoted to CDT demonstrated that the standardization is possible using calibrators assigned to the reference measurement procedure. In this study, we compare the capillary electrophoresis (CE) techniques Capillarys® CDT and Minicap® CDT (Sebia, Lisses, France) to the reference procedure before and after standardization in 126 samples covering the range of CDT measurement. Both capillary electrophoresis procedures show a high correlation (r=0,997) with the reference procedure and the concordance correlation coefficient evaluated according to Mc Bride is "almost perfect" (>0.997 for both CE procedures). The number of results with a relative difference higher than the acceptable difference limit is only 1 for Capillarys® CDT and 5 for Minicap® CDT. These results demonstrate the efficiency of the standardization of CDT measurements for both CE techniques from Sebia, achieved using calibrators assigned to the reference measurement procedure.

  2. 78 FR 23786 - Settlement Conference

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-22

    ... convening a settlement conference between GameFly, Inc. and the Postal Service. This notice informs the.... GameFly Motion, Postal Service Reply, and GameFly Response IV. Analysis V. Settlement Procedures I..., 2013, GameFly, Inc. (GameFly) filed a motion requesting the Commission to establish standards and...

  3. Fracture critical analysis procedures and design and retrofit approaches for pony truss bridges in Ohio.

    DOT National Transportation Integrated Search

    2016-10-01

    The study outlined in this report aimed to quantify the available redundancy in pony truss bridge systems : constructed using standard designs and practices in the state of Ohio. A method of conducting refined : three-dimensional nonlinear finite ele...

  4. STANDARD OPERATING PROCEDURE FOR QUALITY ASSURANCE IN ANALYTICAL CHEMISTRY METHODS DEVELOPMENT

    EPA Science Inventory

    The Environmental Protection Agency's (EPA) Office of Research and Development (ORD) is engaged in the development, demonstration, and validation of new or newly adapted methods of analysis for environmentally related samples. Recognizing that a "one size fits all" approach to qu...

  5. Alternative Strategies in Assessing Special Education Needs

    ERIC Educational Resources Information Center

    Dykeman, Bruce F.

    2006-01-01

    The conventional use of standardized testing within a discrepancy analysis model is reviewed. The Response-to-Intervention (RTI) process is explained, along with descriptions of assessment procedures within RTI: functional assessment, authentic assessment, curriculum-based measurement, and play-based assessment. Psychometric issues relevant to RTI…

  6. Expeditionary Economics: A Force Multiplier in the Counterinsurgency Fight

    DTIC Science & Technology

    2012-05-17

    the Army is the Money as a Weapon System (MAA WS) Standard Operating Procedure. This SOP is infrequently updated and has remained essentially ...Research Series: Expeditionary Economics, 2011 June. Schramm, Carl J. "Institutionalizing Ecnomics Analysis in the U.S. Military: The Basis for

  7. Chemical measurement of urine volume

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.

    1978-01-01

    Chemical method of measuring volume of urine samples using lithium chloride dilution technique, does not interfere with analysis, is faster, and more accurate than standard volumetric of specific gravity/weight techniques. Adaptation of procedure to urinalysis could prove generally practical for hospital mineral balance and catechoamine determinations.

  8. 7 CFR 868.102 - Procedures for establishing and revising grade standards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 7 2012-01-01 2012-01-01 false Procedures for establishing and revising grade....102 Procedures for establishing and revising grade standards. (a) GIPSA will develop, revise, suspend, or terminate grade standards if it determines that such action is in the public interest. GIPSA...

  9. 7 CFR 868.102 - Procedures for establishing and revising grade standards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 7 2013-01-01 2013-01-01 false Procedures for establishing and revising grade....102 Procedures for establishing and revising grade standards. (a) GIPSA will develop, revise, suspend, or terminate grade standards if it determines that such action is in the public interest. GIPSA...

  10. 7 CFR 868.102 - Procedures for establishing and revising grade standards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 7 2010-01-01 2010-01-01 false Procedures for establishing and revising grade....102 Procedures for establishing and revising grade standards. (a) GIPSA will develop, revise, suspend, or terminate grade standards if it determines that such action is in the public interest. GIPSA...

  11. 7 CFR 868.102 - Procedures for establishing and revising grade standards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false Procedures for establishing and revising grade....102 Procedures for establishing and revising grade standards. (a) GIPSA will develop, revise, suspend, or terminate grade standards if it determines that such action is in the public interest. GIPSA...

  12. 7 CFR 868.102 - Procedures for establishing and revising grade standards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false Procedures for establishing and revising grade....102 Procedures for establishing and revising grade standards. (a) GIPSA will develop, revise, suspend, or terminate grade standards if it determines that such action is in the public interest. GIPSA...

  13. PROVIDING A HEALTHFUL SCHOOL ENVIRONMENT. STANDARDS AND PROCEDURES.

    ERIC Educational Resources Information Center

    JOHANNIS, NORMA; AND OTHERS

    THIS REPORT DISCUSSES STANDARDS AND PROCEDURES AS APPLIED TO MENTAL AND PHYSICAL HEALTH AND SAFETY AS AFFECTED BY THE PHYSICAL SURROUNDINGS. A BIBLIOGRAPHY DESCRIBING STANDARDS AND SUGGESTED PROCEDURES, AND A CHECKLIST, ARE PROVIDED FOR VOLUNTARY SELF APPRAISAL. THE CHECKLIST COVERS (1) THE SCHOOL GROUNDS, (2) THE SCHOOL BUILDING, (3)…

  14. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Weatherization materials standards and energy audit procedures. 440.21 Section 440.21 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION WEATHERIZATION ASSISTANCE FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...

  15. 21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...

  16. 40 CFR 63.1549 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the practices described in the standard operating procedures manual required under § 63.1544(a) for... described in the standard operating procedures manual for baghouses required under § 63.1547(a). (6) If an... in the standard operating procedures manual for baghouses required under § 63.1547(a), including an...

  17. 40 CFR 63.1549 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the practices described in the standard operating procedures manual required under § 63.1544(a) for... described in the standard operating procedures manual for baghouses required under § 63.1547(a). (6) If an... in the standard operating procedures manual for baghouses required under § 63.1547(a), including an...

  18. 76 FR 18645 - Third Party Testing for Certain Children's Products; Notice of Requirements for Accreditation of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-05

    ... referenced: The existing CPSC Standard Operating Procedure for Determining Lead (Pb) in Paint and Other... explicitly require the use of a particular standard operating procedure. Additionally, the following....'' It is still based on standard test procedures, such as ASTM International (formerly the American...

  19. 21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...

  20. 40 CFR 63.550 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., corrective action, report, or record, according to § 63.10(b)(1). (b) The standard operating procedures... standard operating procedures manual for baghouses required under § 63.548(a). (4) Electronic records of... required as part of the practices described in the standard operating procedures manual required under § 63...

  1. 21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...

  2. 40 CFR 63.550 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., corrective action, report, or record, according to § 63.10(b)(1). (b) The standard operating procedures... standard operating procedures manual for baghouses required under § 63.548(a). (4) Electronic records of... required as part of the practices described in the standard operating procedures manual required under § 63...

  3. 21 CFR 821.25 - Device tracking system and content requirements: manufacturer requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... manufacturer of a tracked device shall keep current records in accordance with its standard operating procedure... this section. A manufacturer shall make this standard operating procedure available to FDA upon request. A manufacturer shall incorporate the following into the standard operating procedure: (1) Data...

  4. 40 CFR 63.550 - Recordkeeping and reporting requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., corrective action, report, or record, according to § 63.10(b)(1). (b) The standard operating procedures... standard operating procedures manual for baghouses required under § 63.548(a). (4) Electronic records of... required as part of the practices described in the standard operating procedures manual required under § 63...

  5. 76 FR 62074 - Proposed Revision of Performance Standards for State Medicaid Fraud Control Units

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-06

    ... volume of case referrals and workload for each location. Performance Standard 3--Policies and Procedures A Unit establishes written policies and procedures for its operations and ensures that staff are familiar with, and adhere to, policies and procedures. In meeting this standard, the following performance...

  6. 24 CFR 574.510 - Environmental procedures and standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Environmental procedures and standards. 574.510 Section 574.510 Housing and Urban Development Regulations Relating to Housing and Urban... Administration § 574.510 Environmental procedures and standards. (a) Activities under this part are subject to...

  7. 76 FR 54528 - Standard Operating Procedures (SOP) of the Aircraft Certification Service (AIR) Process for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-01

    ...) of the Aircraft Certification Service (AIR) Process for the Sequencing of Certification and... on the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the process... comments on the SOP : AIR-100-001; Standard Operating Procedure--Aircraft Certification Service Project...

  8. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Weatherization materials standards and energy audit procedures. 440.21 Section 440.21 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION WEATHERIZATION ASSISTANCE FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...

  9. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Weatherization materials standards and energy audit procedures. 440.21 Section 440.21 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION WEATHERIZATION ASSISTANCE FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...

  10. 10 CFR 440.21 - Weatherization materials standards and energy audit procedures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Weatherization materials standards and energy audit procedures. 440.21 Section 440.21 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION WEATHERIZATION ASSISTANCE FOR LOW-INCOME PERSONS § 440.21 Weatherization materials standards and energy audit procedures. (a...

  11. Microplastics in Baltic bottom sediments: Quantification procedures and first results.

    PubMed

    Zobkov, M; Esiukova, E

    2017-01-30

    Microplastics in the marine environment are known as a global ecological problem but there are still no standardized analysis procedures for their quantification. The first breakthrough in this direction was the NOAA Laboratory Methods for quantifying synthetic particles in water and sediments, but fibers numbers have been found to be underestimated with this approach. We propose modifications for these methods that will allow us to analyze microplastics in bottom sediments, including small fibers. Addition of an internal standard to sediment samples and occasional empty runs are advised for analysis quality control. The microplastics extraction efficiency using the proposed modifications is 92±7%. Distribution of microplastics in bottom sediments of the Russian part of the Baltic Sea is presented. Microplastic particles were found in all of the samples with an average concentration of 34±10 items/kg DW and have the same order of magnitude as neighbor studies reported. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. [An investigation for standardized diagnosis and treatment of idiopathic normal-pressure hydrocephalus].

    PubMed

    Jiang, H J; Zhang, J M; Fu, W M; Zheng, Z; Luo, W; Zheng, Y X; Zhu, J M

    2016-06-07

    To investigate some important issues for diagnosis and treatment of idiopathic normal-pressure hydrocephalus (iNPH), such as standardized pre-operative assessment, initial pressure value of diverter pump, and pressure regulation during follow-up. Twenty six iNPH patients (21 males) who treated in Department of Neurosurgery of 2nd Affiliated Hospital of Zhejiang University School of Medicine from 2011 to 2015 were analyzed retrospectively. The average age was 60.5 year. The analysis focused on the treatment process of iNPH, initial pressure value of diverter pump, choice of diverter pump, and pressure regulation during follow-up. As a result, 24 cases (92.3%) had a good prognosis based on their imaging and clinical manifestations. Based on the literature and their clinical experiences, this department established a diagnosis and treatment procedure of iNPH and a pressure regulation procedure for the follow-up of iNPH. Moreover, it is proposed that choosing an anti-gravity diverter pump and making an initial pressure value 20 mmH2O less than pre-surgical cerebrospinal pressure may be beneficial for the prognosis. This standardized diagnosis and treatment procedure for iNPH is practical and effective.

  13. Recommended fine positioning test for the Development Test Flight (DTF-1) of the NASA Flight Telerobotic Servicer (FTS)

    NASA Technical Reports Server (NTRS)

    Dagalakis, N.; Wavering, A. J.; Spidaliere, P.

    1991-01-01

    Test procedures are proposed for the NASA DTF (Development Test Flight)-1 positioning tests of the FTS (Flight Telerobotic Servicer). The unique problems associated with the DTF-1 mission are discussed, standard robot performance tests and terminology are reviewed and a very detailed description of flight-like testing and analysis is presented. The major technical problem associated with DTF-1 is that only one position sensor can be used, which will be fixed at one location, with a working volume which is probably smaller than some of the robot errors to be measured. Radiation heating of the arm and the sensor could also cause distortions that would interfere with the test. Two robot performance testing committees have established standard testing procedures relevant to the DTF-1. Due to the technical problems associated with DTF-1, these procedures cannot be applied directly. These standard tests call for the use of several test positions at specific locations. Only one position, that of the position sensor, can be used by DTF-1. Off-line programming accuracy might be impossible to measure and in that case it will have to be replaced by forward kinetics accuracy.

  14. Transfer of knowledge in international cooperation: the Farmanguinhos – SMM case

    PubMed Central

    da Silva, Samuel Araujo Gomes; Duarte, Roberto Gonzalez; de Castro, José Márcio

    2017-01-01

    ABSTRACT OBJECTIVE To analyze the influence of four mechanisms of knowledge transfer (training, technical visits, expatriation, and standard operating procedures) on the different dimensions (potential and realized) of absorptive capacity in international technical cooperation. METHODS We examine the case of implementation of the Sociedade Moçambicana de Medicamentos. Data have been collected using semi-structured interviews (applied to 21 professionals of the Sociedade Moçambicana de Medicamentos, Farmanguinhos, FIOCRUZ, and Itamaraty) and official documents. The data of the interviews have been submitted to content analysis, using the software NVivo. RESULTS Training and technical visits directly influenced the acquisition and, partly, the assimilation of knowledge. Expatriation contributed with the transformation of this knowledge from the development and refinement of operational routines. Finally, the definition of standard operating procedures allowed the Mozambican technicians to be the actors of the transformation of the knowledge previously acquired and assimilated and, at the same time, it laid the foundations for a future exploration of the knowledge. CONCLUSIONS Training and technical visits mainly influence the potential absorptive capacity, while expatriation and standard operating procedures most directly affect the realized absorptive capacity. PMID:29166441

  15. A single-step simultaneous protein staining procedure for polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis.

    PubMed

    Pal, Jayanta K; Berwal, Sunil K; Soni, Rupali N

    2012-01-01

    A simple method for staining of proteins simultaneously on sodium dodecyl sulfate (SDS) polyacrylamide gels and nitrocellulose membranes by Alta during western blot analysis is described. A 5% solution of Alta, a commercially available cosmetic preparation, is added in the upper tank buffer during electrophoresis. On completion of electrophoresis, the gel is washed in distilled water and viewed on a white light plate and a transilluminator to photograph the protein profiles. The gel is processed for western blot transfer of proteins onto a nitrocellulose membrane, and upon completion, the protein profiles on the membrane are viewed and photographed as stated above. The membrane can then be processed for immunostaining as per the standard procedure. Thus, the staining procedure using Alta is simple, rapid (without any need of destaining), and cost-effective.

  16. Knowledge Management Orientation: An Innovative Perspective to Hospital Management.

    PubMed

    Ghasemi, Matina; Ghadiri Nejad, Mazyar; Bagzibagli, Kemal

    2017-12-01

    By considering innovation as a new project in hospitals, all the project management's standard steps should be followed in execution. This study investigated the validation of a new set of measures in terms of providing a procedure for knowledge management-oriented innovation that enriches the hospital management system. The relation between innovation and all the knowledge management areas, as the main constructs of project management, was illustrated by referring to project management standard steps and previous studies. Through consultations and meetings with a committee of professional project managers, a questionnaire was developed to measure ten knowledge management areas in hospital's innovation process. Additionally, a group of experts from hospital managers were invited to comment on the applicability of the questionnaires by considering if the items are measurable in hospitals practically. A close-ended, Likert-type scale items, consisted of ten sections, were developed based on project management body of knowledge thorough Delphi technique. It enables the managers to evaluate hospitals' situation to be aware whether the organization follows the knowledge management standards in innovation process or not. By pilot study, confirmatory factor analysis and exploratory factor analysis were conducted to ensure the validity and reliability of the measurement items. The developed items seem to have a potential to help hospital managers and subsequently delivering new products/services successfully based on the standard procedures in their organization. In all innovation processes, the knowledge management areas and their standard steps help hospital managers by a new tool as questionnaire format.

  17. The metagenomic data life-cycle: standards and best practices

    PubMed Central

    ten Hoopen, Petra; Finn, Robert D.; Bongo, Lars Ailo; Corre, Erwan; Meyer, Folker; Mitchell, Alex; Pelletier, Eric; Pesole, Graziano; Santamaria, Monica; Willassen, Nils Peder

    2017-01-01

    Abstract Metagenomics data analyses from independent studies can only be compared if the analysis workflows are described in a harmonized way. In this overview, we have mapped the landscape of data standards available for the description of essential steps in metagenomics: (i) material sampling, (ii) material sequencing, (iii) data analysis, and (iv) data archiving and publishing. Taking examples from marine research, we summarize essential variables used to describe material sampling processes and sequencing procedures in a metagenomics experiment. These aspects of metagenomics dataset generation have been to some extent addressed by the scientific community, but greater awareness and adoption is still needed. We emphasize the lack of standards relating to reporting how metagenomics datasets are analysed and how the metagenomics data analysis outputs should be archived and published. We propose best practice as a foundation for a community standard to enable reproducibility and better sharing of metagenomics datasets, leading ultimately to greater metagenomics data reuse and repurposing. PMID:28637310

  18. The metagenomic data life-cycle: standards and best practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ten Hoopen, Petra; Finn, Robert D.; Bongo, Lars Ailo

    Metagenomics data analyses from independent studies can only be compared if the analysis workflows are described in a harmonised way. In this overview, we have mapped the landscape of data standards available for the description of essential steps in metagenomics: (1) material sampling, (2) material sequencing (3) data analysis and (4) data archiving & publishing. Taking examples from marine research, we summarise essential variables used to describe material sampling processes and sequencing procedures in a metagenomics experiment. These aspects of metagenomics dataset generation have been to some extent addressed by the scientific community but greater awareness and adoption is stillmore » needed. We emphasise the lack of standards relating to reporting how metagenomics datasets are analysed and how the metagenomics data analysis outputs should be archived and published. We propose best practice as a foundation for a community standard to enable reproducibility and better sharing of metagenomics datasets, leading ultimately to greater metagenomics data reuse and repurposing.« less

  19. Species-specific diagnostic assays for Bonamia ostreae and B. exitiosa in European flat oyster Ostrea edulis: conventional, real-time and multiplex PCR.

    PubMed

    Ramilo, Andrea; Navas, J Ignacio; Villalba, Antonio; Abollo, Elvira

    2013-05-27

    Bonamia ostreae and B. exitiosa have caused mass mortalities of various oyster species around the world and co-occur in some European areas. The World Organisation for Animal Health (OIE) has included infections with both species in the list of notifiable diseases. However, official methods for species-specific diagnosis of either parasite have certain limitations. In this study, new species-specific conventional PCR (cPCR) and real-time PCR techniques were developed to diagnose each parasite species. Moreover, a multiplex PCR method was designed to detect both parasites in a single assay. The analytical sensitivity and specificity of each new method were evaluated. These new procedures were compared with 2 OIE-recommended methods, viz. standard histology and PCR-RFLP. The new procedures showed higher sensitivity than the OIE recommended ones for the diagnosis of both species. The sensitivity of tests with the new primers was higher using oyster gills and gonad tissue, rather than gills alone. The lack of a 'gold standard' prevented accurate estimation of sensitivity and specificity of the new methods. The implementation of statistical tools (maximum likelihood method) for the comparison of the diagnostic tests showed the possibility of false positives with the new procedures, although the absence of a gold standard precluded certainty. Nevertheless, all procedures showed negative results when used for the analysis of oysters from a Bonamia-free area.

  20. Economic Assessment and Budgetary Impact of a Telemedicine Procedure and Spirometry Quality Control in the Primary Care Setting.

    PubMed

    Marina, Nuria; Bayón, Juan Carlos; López de Santa María, Elena; Gutiérrez, Asunción; Inchausti, Marta; Bustamante, Victor; Gáldiz, Juan B

    2016-01-01

    To evaluate the economic impact of a telemedicine procedure designed to improve the quality of lung function testing (LFT) in primary care in a public healthcare system, compared with the standard method. The economic impact of 9,039 LFTs performed in 51 health centers (2010-2013) using telespirometry (TS) compared to standard spirometry (SS) was studied. TS costs more per unit than SS (€47.80 vs. €39.70) (2013), but the quality of the TS procedure is superior (84% good quality, compared to 61% using the standard procedure). Total cost of TS was €431,974 (compared with €358,306€ for SS), generating an economic impact of €73,668 (2013). The increase in cost for good quality LFT performed using TS was €34,030 (2010) and €144,295 (2013), while the costs of poor quality tests fell by €15,525 (2010) and 70,627€ (2013). The cost-effectiveness analysis concludes that TS is 23% more expensive and 46% more effective. Healthcare costs consequently fall as the number of LFTs performed by TS rises. Avoiding poor quality, invalid LFTs generates savings that compensate for the increased costs of performing LFTs with TS, making it a cost-effective method. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  1. Identifying inaccuracy of MS Project using system analysis

    NASA Astrophysics Data System (ADS)

    Fachrurrazi; Husin, Saiful; Malahayati, Nurul; Irzaidi

    2018-05-01

    The problem encountered in project owner’s financial accounting report is the difference in total project costs of MS Project to the Indonesian Standard (Standard Indonesia Standard / Cost Estimating Standard Book of Indonesia). It is one of the MS Project problems concerning to its cost accuracy, so cost data cannot be used in an integrated way for all project components. This study focuses on finding the causes of inaccuracy of the MS Projects. The aim of this study, which is operationally, are: (i) identifying cost analysis procedures for both current methods (SNI) and MS Project; (ii) identifying cost bias in each element of the cost analysis procedure; and (iii) analysing the cost differences (cost bias) in each element to identify what the cause of inaccuracies in MS Project toward SNI is. The method in this study is comparing for both the system analysis of MS Project and SNI. The results are: (i) MS Project system in Work of Resources element has limitation for two decimal digits only, have led to its inaccuracy. Where the Work of Resources (referred to as effort) in MS Project represents multiplication between the Quantities of Activities and Requirements of resources in SNI; (ii) MS Project and SNI have differences in the costing methods (the cost estimation methods), in which the SNI uses the Quantity-Based Costing (QBC), meanwhile MS Project uses the Time-Based Costing (TBC). Based on this research, we recommend to the contractors who use SNI should make an adjustment for Work of Resources in MS Project (with correction index) so that it can be used in an integrated way to the project owner’s financial accounting system. Further research will conduct for improvement the MS Project as an integrated tool toward all part of the project participant.

  2. International Committee for Monitoring Assisted Reproductive Technology (ICMART) and the World Health Organization (WHO) revised glossary of ART terminology, 2009.

    PubMed

    Zegers-Hochschild, F; Adamson, G D; de Mouzon, J; Ishihara, O; Mansour, R; Nygren, K; Sullivan, E; Vanderpoel, S

    2009-11-01

    Many definitions used in medically assisted reproduction (MAR) vary in different settings, making it difficult to standardize and compare procedures in different countries and regions. With the expansion of infertility interventions worldwide, including lower resource settings, the importance and value of a common nomenclature is critical. The objective is to develop an internationally accepted and continually updated set of definitions, which would be utilized to standardize and harmonize international data collection, and to assist in monitoring the availability, efficacy, and safety of assisted reproductive technology (ART) being practiced worldwide. Seventy-two clinicians, basic scientists, epidemiologists and social scientists gathered together at the World Health Organization headquarters in Geneva, Switzerland, in December 2008. Several months before, three working groups were established as responsible for terminology in three specific areas: clinical conditions and procedures, laboratory procedures, and outcome measures. Each group reviewed the existing International Committee for Monitoring Assisted Reproductive Technology glossary, made recommendations for revisions and introduced new terms to be considered for glossary expansion. A consensus was reached on 87 terms, expanding the original glossary by 34 terms, which included definitions for numerous clinical and laboratory procedures. Special emphasis was placed in describing outcome measures, such as cumulative delivery rates and other markers of safety and efficacy in ART. Standardized terminology should assist in analysis of worldwide trends in MAR interventions and in the comparison of ART outcomes across countries and regions. This glossary will contribute to a more standardized communication among professionals responsible for ART practice, as well as those responsible for national, regional, and international registries.

  3. The International Committee for Monitoring Assisted Reproductive Technology (ICMART) and the World Health Organization (WHO) Revised Glossary on ART Terminology, 2009.

    PubMed

    Zegers-Hochschild, F; Adamson, G D; de Mouzon, J; Ishihara, O; Mansour, R; Nygren, K; Sullivan, E; van der Poel, S

    2009-11-01

    Many definitions used in medically assisted reproduction (MAR) vary in different settings, making it difficult to standardize and compare procedures in different countries and regions. With the expansion of infertility interventions worldwide, including lower resource settings, the importance and value of a common nomenclature is critical. The objective is to develop an internationally accepted and continually updated set of definitions, which would be utilized to standardize and harmonize international data collection, and to assist in monitoring the availability, efficacy, and safety of assisted reproductive technology (ART) being practiced worldwide. Seventy-two clinicians, basic scientists, epidemiologists and social scientists gathered together at the WHO headquarters in Geneva, Switzerland in December, 2008. Several months in advance, three working groups were established which were responsible for terminology in three specific areas: clinical conditions and procedures, laboratory procedures and outcome measures. Each group reviewed the existing ICMART glossary, made recommendations for revisions and introduced new terms to be considered for glossary expansion. A consensus was reached on 87 terms, expanding the original glossary by 34 terms, which included definitions for numerous clinical and laboratory procedures. Special emphasis was placed in describing outcome measures such as cumulative delivery rates and other markers of safety and efficacy in ART. Standardized terminology should assist in analysis of worldwide trends in MAR interventions and in the comparison of ART outcomes across countries and regions. This glossary will contribute to a more standardized communication among professionals responsible for ART practice, as well as those responsible for national, regional and international registries.

  4. Grass material as process standard for compound-specific radiocarbon analysis

    NASA Astrophysics Data System (ADS)

    Cisneros-Dozal, Malu; Xu, Xiaomei; Bryant, Charlotte; Pearson, Emma; Dungait, Jennifer

    2015-04-01

    Compound-specific radiocarbon analysis (CSRA) is a powerful tool to study the carbon cycle and/or as a dating technique in paleoclimate reconstructions. The radiocarbon value of individual compounds can provide insight into turnover times, organic matter sources and in specific cases can be used to establish chronologies when traditional dating materials (e.g. macrofossils, pollen, charcoal) are not available. The isolation of compounds (or group of compounds) from parent material (e.g. soil, plant) for radiocarbon analysis can, however, introduce carbon contamination through chemical separation steps and preparative capillary gas chromatography (PCGC). In addition, the compounds of interest are often in low abundance which amplifies the contamination effect. The extraneous carbon can be of modern 14C age and/or 14C -free and its amount and 14C value must be determined for a given system/isolation procedure in order to report accurate 14C values. This can be achieved by using adequate standard materials but, by contrast with traditional radiocarbon dating, there are not established reference standards for CSRA work, in part because the type of standard material depends on the compounds of interest and the isolation procedure. Here we evaluate the use of n-alkanes extracted from single-year growth grass as modern process standard material for CSRA using PCGC isolation. The grass material has a known 14C value of 1.224 ± 0.006 fraction modern (FM) and the individual n-alkanes are expected to have a similar 14C value. In order to correct for the addition of extraneous carbon during PCGC isolation of the n-alkanes, we used commercially available compounds of modern 14C content and 14C -free (adipic acid, FM= 0.0015 ± 0.0001 and docosane, FM=1.059 ± 0.003) to evaluate our PCGC procedure. The corrected 14C values of the isolated n-alkanes extracted from the modern grass are within one sigma of the grass bulk 14C value for n-C29 and within two sigma for n-C23-C27, C31 and C33. Our results show that single-year growth grass can be a process standard suitable for quality control of extraction of n-alkanes (and potentially other compounds) from soil or plant material for CSRA.

  5. The Effect of Geographic Units of Analysis on Measuring Geographic Variation in Medical Services Utilization.

    PubMed

    Kim, Agnus M; Park, Jong Heon; Kang, Sungchan; Hwang, Kyosang; Lee, Taesik; Kim, Yoon

    2016-07-01

    We aimed to evaluate the effect of geographic units of analysis on measuring geographic variation in medical services utilization. For this purpose, we compared geographic variations in the rates of eight major procedures in administrative units (districts) and new areal units organized based on the actual health care use of the population in Korea. To compare geographic variation in geographic units of analysis, we calculated the age-sex standardized rates of eight major procedures (coronary artery bypass graft surgery, percutaneous transluminal coronary angioplasty, surgery after hip fracture, knee-replacement surgery, caesarean section, hysterectomy, computed tomography scan, and magnetic resonance imaging scan) from the National Health Insurance database in Korea for the 2013 period. Using the coefficient of variation, the extremal quotient, and the systematic component of variation, we measured geographic variation for these eight procedures in districts and new areal units. Compared with districts, new areal units showed a reduction in geographic variation. Extremal quotients and inter-decile ratios for the eight procedures were lower in new areal units. While the coefficient of variation was lower for most procedures in new areal units, the pattern of change of the systematic component of variation between districts and new areal units differed among procedures. Geographic variation in medical service utilization could vary according to the geographic unit of analysis. To determine how geographic characteristics such as population size and number of geographic units affect geographic variation, further studies are needed.

  6. Applications of Automation Methods for Nonlinear Fracture Test Analysis

    NASA Technical Reports Server (NTRS)

    Allen, Phillip A.; Wells, Douglas N.

    2013-01-01

    Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.

  7. Wind Characterization for the Assessment of Collision Risk During Flight Level Changes

    NASA Technical Reports Server (NTRS)

    Carreno, Victor; Chartrand, Ryan

    2009-01-01

    A model of vertical wind gradient is presented based on National Oceanic and Atmospheric Administration (NOAA) wind data. The objective is to have an accurate representation of wind to be used in Collision Risk Models (CRM) of aircraft procedures. Depending on how an aircraft procedure is defined, wind and the different characteristics of the wind will have a more severe or less severe impact on distances between aircraft. For the In-Trail Procedure, the non-linearity of the vertical wind gradient has the greatest impact on longitudinal distance. The analysis in this paper extracts standard deviation, mean, maximum, and linearity characteristics from the NOAA data.

  8. New γ -radiation screening procedures of infrared focal plane arrays (IR FPA)

    NASA Astrophysics Data System (ADS)

    Chen, Hong-lei; Hao, Lichao; Huang, Ai-Bo; Lin, Jiamu; Zhang, Jun-ling; Feng, Qi; Ding, Rui-jun

    2013-01-01

    Infrared focal plane HgCdTe device is used in the environment of complicated astrospace radiation. To achieve the instrument's actual service life, the anti-radiation ability is needed to study in our research. The irradiation-induced invalidation mechanism of semiconductor materials is introduced in this paper, and the screening experiments' total radiation dose of American Military Standard is also investigated in our study. Through the simulation of astrospace radiation effect by γ -irradiation, the experimental procedures are proved to be rational by the analysis of the experimental data. With the domestic conditions, radiation screening procedures which meets the practical need is suggested.

  9. The effect of column purification on cDNA indirect labelling for microarrays

    PubMed Central

    Molas, M Lia; Kiss, John Z

    2007-01-01

    Background The success of the microarray reproducibility is dependent upon the performance of standardized procedures. Since the introduction of microarray technology for the analysis of global gene expression, reproducibility of results among different laboratories has been a major problem. Two of the main contributors to this variability are the use of different microarray platforms and different laboratory practices. In this paper, we address the latter question in terms of how variation in one of the steps of a labelling procedure affects the cDNA product prior to microarray hybridization. Results We used a standard procedure to label cDNA for microarray hybridization and employed different types of column chromatography for cDNA purification. After purifying labelled cDNA, we used the Agilent 2100 Bioanalyzer and agarose gel electrophoresis to assess the quality of the labelled cDNA before its hybridization onto a microarray platform. There were major differences in the cDNA profile (i.e. cDNA fragment lengths and abundance) as a result of using four different columns for purification. In addition, different columns have different efficiencies to remove rRNA contamination. This study indicates that the appropriate column to use in this type of protocol has to be experimentally determined. Finally, we present new evidence establishing the importance of testing the method of purification used during an indirect labelling procedure. Our results confirm the importance of assessing the quality of the sample in the labelling procedure prior to hybridization onto a microarray platform. Conclusion Standardization of column purification systems to be used in labelling procedures will improve the reproducibility of microarray results among different laboratories. In addition, implementation of a quality control check point of the labelled samples prior to microarray hybridization will prevent hybridizing a poor quality sample to expensive micorarrays. PMID:17597522

  10. The effect of column purification on cDNA indirect labelling for microarrays.

    PubMed

    Molas, M Lia; Kiss, John Z

    2007-06-27

    The success of the microarray reproducibility is dependent upon the performance of standardized procedures. Since the introduction of microarray technology for the analysis of global gene expression, reproducibility of results among different laboratories has been a major problem. Two of the main contributors to this variability are the use of different microarray platforms and different laboratory practices. In this paper, we address the latter question in terms of how variation in one of the steps of a labelling procedure affects the cDNA product prior to microarray hybridization. We used a standard procedure to label cDNA for microarray hybridization and employed different types of column chromatography for cDNA purification. After purifying labelled cDNA, we used the Agilent 2100 Bioanalyzer and agarose gel electrophoresis to assess the quality of the labelled cDNA before its hybridization onto a microarray platform. There were major differences in the cDNA profile (i.e. cDNA fragment lengths and abundance) as a result of using four different columns for purification. In addition, different columns have different efficiencies to remove rRNA contamination. This study indicates that the appropriate column to use in this type of protocol has to be experimentally determined. Finally, we present new evidence establishing the importance of testing the method of purification used during an indirect labelling procedure. Our results confirm the importance of assessing the quality of the sample in the labelling procedure prior to hybridization onto a microarray platform. Standardization of column purification systems to be used in labelling procedures will improve the reproducibility of microarray results among different laboratories. In addition, implementation of a quality control check point of the labelled samples prior to microarray hybridization will prevent hybridizing a poor quality sample to expensive micorarrays.

  11. Documentation for assessment of modal pushover-based scaling procedure for nonlinear response history analysis of "ordinary standard" bridges

    USGS Publications Warehouse

    Kalkan, Erol; Kwong, Neal S.

    2010-01-01

    The earthquake engineering profession is increasingly utilizing nonlinear response history analyses (RHA) to evaluate seismic performance of existing structures and proposed designs of new structures. One of the main ingredients of nonlinear RHA is a set of ground-motion records representing the expected hazard environment for the structure. When recorded motions do not exist (as is the case for the central United States), or when high-intensity records are needed (as is the case for San Francisco and Los Angeles), ground motions from other tectonically similar regions need to be selected and scaled. The modal-pushover-based scaling (MPS) procedure recently was developed to determine scale factors for a small number of records, such that the scaled records provide accurate and efficient estimates of 'true' median structural responses. The adjective 'accurate' refers to the discrepancy between the benchmark responses and those computed from the MPS procedure. The adjective 'efficient' refers to the record-to-record variability of responses. Herein, the accuracy and efficiency of the MPS procedure are evaluated by applying it to four types of existing 'ordinary standard' bridges typical of reinforced-concrete bridge construction in California. These bridges are the single-bent overpass, multi span bridge, curved-bridge, and skew-bridge. As compared to benchmark analyses of unscaled records using a larger catalog of ground motions, it is demonstrated that the MPS procedure provided an accurate estimate of the engineering demand parameters (EDPs) accompanied by significantly reduced record-to-record variability of the responses. Thus, the MPS procedure is a useful tool for scaling ground motions as input to nonlinear RHAs of 'ordinary standard' bridges.

  12. Evaluation of modal pushover-based scaling of one component of ground motion: Tall buildings

    USGS Publications Warehouse

    Kalkan, Erol; Chopra, Anil K.

    2012-01-01

    Nonlinear response history analysis (RHA) is now increasingly used for performance-based seismic design of tall buildings. Required for nonlinear RHAs is a set of ground motions selected and scaled appropriately so that analysis results would be accurate (unbiased) and efficient (having relatively small dispersion). This paper evaluates accuracy and efficiency of recently developed modal pushover–based scaling (MPS) method to scale ground motions for tall buildings. The procedure presented explicitly considers structural strength and is based on the standard intensity measure (IM) of spectral acceleration in a form convenient for evaluating existing structures or proposed designs for new structures. Based on results presented for two actual buildings (19 and 52 stories, respectively), it is demonstrated that the MPS procedure provided a highly accurate estimate of the engineering demand parameters (EDPs), accompanied by significantly reduced record-to-record variability of the responses. In addition, the MPS procedure is shown to be superior to the scaling procedure specified in the ASCE/SEI 7-05 document.

  13. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data.

    PubMed

    Tekwe, Carmen D; Carroll, Raymond J; Dabney, Alan R

    2012-08-01

    Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. ctekwe@stat.tamu.edu.

  14. Command Process Modeling & Risk Analysis

    NASA Technical Reports Server (NTRS)

    Meshkat, Leila

    2011-01-01

    Commanding Errors may be caused by a variety of root causes. It's important to understand the relative significance of each of these causes for making institutional investment decisions. One of these causes is the lack of standardized processes and procedures for command and control. We mitigate this problem by building periodic tables and models corresponding to key functions within it. These models include simulation analysis and probabilistic risk assessment models.

  15. To Leave or Not to Leave? A Regression Discontinuity Analysis of the Impact of Failing the High School Exit Exam

    ERIC Educational Resources Information Center

    Ou, Dongshu

    2010-01-01

    The high school exit exam (HSEE) is rapidly becoming a standardized assessment procedure for educational accountability in the United States. I use a unique, state-specific dataset to identify the effects of failing the HSEE on the likelihood of dropping out of high school based on a regression discontinuity design. The analysis shows that…

  16. U.S.-MEXICO BORDER PROGRAM ARIZONA BORDER STUDY--STANDARD OPERATING PROCEDURE--COMPENDIUM OF METHOD SUMMARIES FOR COLLECTION AND ANALYSIS OF METALS, PESTICIDE METABOLITES, AND VOC IN BLOOD AND URINE (CDC-COMPENDIUM)

    EPA Science Inventory

    This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). The pr...

  17. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR EXTRACTION OF AIR SAMPLES FOR GC/MS ANALYSIS OF PESTICIDE AND PAH (BCO-L-27.0)

    EPA Science Inventory

    The purpose of this SOP is to describe methods for extracting and preparing an air sample consisting of a quartz fiber filter (Pallflex) and an XAD-2 cartridge for analysis of pesticides and polyaromatic hydrocarbons (PAHs). It covers the preparation of samples that are to be an...

  18. Methyl oleate as matrix simulacrum for the simultaneous determination of metals in biodiesel samples by flame atomic emission spectroscopy.

    PubMed

    Cerai Ferreira, Conny; Malta Costa, Letícia; Sanches Barbeira, Paulo Jorge

    2015-06-01

    A measurement procedure for direct and simultaneous quantification of Na, K and Ca in biodiesel by flame atomic emission spectroscopy (FAES) was developed. A lab-made device was constructed by coupling a nebulizer/combustion system from a commercial photometer to a continuous emission detector in a spectral range of 255 to 862 nm. Instrumental optimizations were carried out evaluating the most important variables, such as gas flow rates and sample introduction temperature, indicating that a temperature of 50°C enhances the analytical signals and assures good precision. The direct analysis method was properly validated and presented limits of quantification of 0.09, 0.07 and 0.43 μg kg(-1) for Na, K and Ca, respectively. Accuracy of the proposed procedure was checked by comparing the results with those obtained by the standard procedure described in ABNT NBR 15556 and the standard addition method. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Procedures and Standards Handbook. Version 3.0. What Works Clearinghouse

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2014

    2014-01-01

    This "What Works Clearinghouse Procedures and Standards Handbook (Version 3.0)" provides a detailed description of the standards and procedures of the What Works Clearinghouse (WWC). The remaining chapters of this Handbook are organized to take the reader through the basic steps that the WWC uses to develop a review protocol, identify…

  20. 46 CFR 160.055-9 - Procedure for approval-standard and nonstandard life preservers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Procedure for approval-standard and nonstandard life preservers. 160.055-9 Section 160.055-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED..., Unicellular Plastic Foam, Adult and Child, for Merchant Vessels § 160.055-9 Procedure for approval—standard...

  1. 77 FR 4698 - Energy Conservation Program: Test Procedure and Energy Conservation Standard for Set-Top Boxes...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-31

    ... Conservation Program: Test Procedure and Energy Conservation Standard for Set-Top Boxes and Network Equipment... comments on the request for information pertaining to the development of test procedures and energy conservation standards for set-top boxes and network equipment. The comment period is extended to March 15...

  2. 49 CFR 231.35 - Procedure for modification of an approved industry safety appliance standard for new railcar...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... industry safety appliance standard for new construction of railroad cars, locomotives, tenders, or other... 49 Transportation 4 2013-10-01 2013-10-01 false Procedure for modification of an approved industry... TRANSPORTATION RAILROAD SAFETY APPLIANCE STANDARDS § 231.35 Procedure for modification of an approved industry...

  3. 49 CFR 231.35 - Procedure for modification of an approved industry safety appliance standard for new railcar...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... industry safety appliance standard for new construction of railroad cars, locomotives, tenders, or other... 49 Transportation 4 2014-10-01 2014-10-01 false Procedure for modification of an approved industry... TRANSPORTATION RAILROAD SAFETY APPLIANCE STANDARDS § 231.35 Procedure for modification of an approved industry...

  4. 49 CFR 231.35 - Procedure for modification of an approved industry safety appliance standard for new railcar...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... industry safety appliance standard for new construction of railroad cars, locomotives, tenders, or other... 49 Transportation 4 2012-10-01 2012-10-01 false Procedure for modification of an approved industry... TRANSPORTATION RAILROAD SAFETY APPLIANCE STANDARDS § 231.35 Procedure for modification of an approved industry...

  5. 49 CFR 231.35 - Procedure for modification of an approved industry safety appliance standard for new railcar...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... industry safety appliance standard for new construction of railroad cars, locomotives, tenders, or other... 49 Transportation 4 2011-10-01 2011-10-01 false Procedure for modification of an approved industry... TRANSPORTATION RAILROAD SAFETY APPLIANCE STANDARDS § 231.35 Procedure for modification of an approved industry...

  6. Valid internal standard technique for arson detection based on gas chromatography-mass spectrometry.

    PubMed

    Salgueiro, Pedro A S; Borges, Carlos M F; Bettencourt da Silva, Ricardo J N

    2012-09-28

    The most popular procedures for the detection of residues of accelerants in fire debris are the ones published by the American Society for Testing and Materials (ASTM E1412-07 and E1618-10). The most critical stages of these tests are the conservation of fire debris from the sampling to the laboratory, the extraction of residues of accelerants from the debris to the activated charcoal strips (ACS) and from those to the final solvent, as well as the analysis of sample extract by gas chromatography-mass spectrometry (GC-MS) and the interpretation of the instrumental signal. This work proposes a strategy for checking the quality of the sample conservation, the accelerant residues transference to final solvent and GC-MS analysis, using internal standard additions. It is used internal standards ranging from a highly volatile compound for checking debris conservation to low volatile compound for checking GC-MS repeatability. The developed quality control (QC) parameters are not affected by GC-MS sensitivity variation and, specifically, the GC-MS performance control is not affected by ACS adsorption saturation that may mask test performance deviations. The proposed QC procedure proved to be adequate to check GC-MS repeatability, ACS extraction and sample conservation since: (1) standard additions are affected by negligible uncertainty and (2) observed dispersion of QC parameters are fit for its intended use. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. 21 CFR 861.30 - Development of standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Development of standards. 861.30 Section 861.30...) MEDICAL DEVICES PROCEDURES FOR PERFORMANCE STANDARDS DEVELOPMENT Procedures for Performance Standards Development and Publication § 861.30 Development of standards. The Food and Drug Administration (FDA), while...

  8. 21 CFR 861.30 - Development of standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Development of standards. 861.30 Section 861.30...) MEDICAL DEVICES PROCEDURES FOR PERFORMANCE STANDARDS DEVELOPMENT Procedures for Performance Standards Development and Publication § 861.30 Development of standards. The Food and Drug Administration (FDA), while...

  9. 15 CFR 10.13 - Withdrawal of a published standard.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... substantial public impact, that it does not duplicate a standard published by a private standards-writing...) Before withdrawing a standard published under these procedures, the Director will review the relative... years. (2) Public notice of intent to withdraw an existing standard published under these procedures...

  10. 15 CFR 10.13 - Withdrawal of a published standard.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... substantial public impact, that it does not duplicate a standard published by a private standards-writing...) Before withdrawing a standard published under these procedures, the Director will review the relative... years. (2) Public notice of intent to withdraw an existing standard published under these procedures...

  11. 15 CFR 10.13 - Withdrawal of a published standard.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... substantial public impact, that it does not duplicate a standard published by a private standards-writing...) Before withdrawing a standard published under these procedures, the Director will review the relative... years. (2) Public notice of intent to withdraw an existing standard published under these procedures...

  12. 15 CFR 10.13 - Withdrawal of a published standard.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... substantial public impact, that it does not duplicate a standard published by a private standards-writing...) Before withdrawing a standard published under these procedures, the Director will review the relative... years. (2) Public notice of intent to withdraw an existing standard published under these procedures...

  13. A comparative analysis of modified binders : original asphalts and materials extracted from existing pavements : technical summary.

    DOT National Transportation Integrated Search

    2010-01-01

    The initial objective of this research was to develop procedures and standards for applying GPC as an analytical tool to define the percentage amounts of polymer modifiers in polymer modified asphalt cements soluble in eluting GPC solvents. Quantific...

  14. Curve numbers for no-till: field data versus standard tables

    USDA-ARS?s Scientific Manuscript database

    The Curve Number procedure developed by Soil Conservation Service (Now Natural Resources Conservation Service) in the mid-1950s for estimating direct runoff from rainstorms has not been extensively tested in cropping systems under no-till. Analysis of CNs using the frequency matching and asymptotic ...

  15. 7 CFR 42.122 - Applicability of other procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....122 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR CONDITION OF FOOD CONTAINERS Skip Lot Sampling and Inspection Procedures § 42.122...

  16. 7 CFR 42.136 - Applicability of other procedures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....136 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR CONDITION OF FOOD CONTAINERS On-Line Sampling and Inspection Procedures § 42.136...

  17. 21 CFR 606.60 - Equipment.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... prescribed in the Standard Operating Procedures Manual and shall perform in the manner for which it was... Hemoglobinometer Standardize against cyanmethemoglobin standard ......do Refractometer Standardize against... microorganisms. The effectiveness of the sterilization procedure shall be no less than that achieved by an...

  18. 21 CFR 606.60 - Equipment.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... prescribed in the Standard Operating Procedures Manual and shall perform in the manner for which it was... Hemoglobinometer Standardize against cyanmethemoglobin standard ......do Refractometer Standardize against... microorganisms. The effectiveness of the sterilization procedure shall be no less than that achieved by an...

  19. 21 CFR 606.60 - Equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... prescribed in the Standard Operating Procedures Manual and shall perform in the manner for which it was... Hemoglobinometer Standardize against cyanmethemoglobin standard ......do Refractometer Standardize against... microorganisms. The effectiveness of the sterilization procedure shall be no less than that achieved by an...

  20. 21 CFR 606.60 - Equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... prescribed in the Standard Operating Procedures Manual and shall perform in the manner for which it was... Hemoglobinometer Standardize against cyanmethemoglobin standard ......do Refractometer Standardize against... microorganisms. The effectiveness of the sterilization procedure shall be no less than that achieved by an...

Top