Martin, Jeffrey D.
2002-01-01
Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.
Weigel, Stefan; Peters, Ruud; Loeschner, Katrin; Grombe, Ringo; Linsinger, Thomas P J
2017-08-01
Single-particle inductively coupled plasma mass spectrometry (sp-ICP-MS) promises fast and selective determination of nanoparticle size and number concentrations. While several studies on practical applications have been published, data on formal, especially interlaboratory validation of sp-ICP-MS, is sparse. An international interlaboratory study was organized to determine repeatability and reproducibility of the determination of the median particle size and particle number concentration of Ag nanoparticles (AgNPs) in chicken meat. Ten laboratories from the European Union, the USA, and Canada determined particle size and particle number concentration of two chicken meat homogenates spiked with polyvinylpyrrolidone (PVP)-stabilized AgNPs. For the determination of the median particle diameter, repeatability standard deviations of 2 and 5% were determined, and reproducibility standard deviations were 15 and 25%, respectively. The equivalent median diameter itself was approximately 60% larger than the diameter of the particles in the spiking solution. Determination of the particle number concentration was significantly less precise, with repeatability standard deviations of 7 and 18% and reproducibility standard deviations of 70 and 90%.
30 CFR 74.8 - Measurement, accuracy, and reliability requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... concentration, as defined by the relative standard deviation of the distribution of measurements. The relative standard deviation shall be less than 0.1275 without bias for both full-shift measurements of 8 hours or... Standards, Regulations, and Variances, 1100 Wilson Boulevard, Room 2350, Arlington, Virginia 22209-3939...
Is standard deviation of daily PM2.5 concentration associated with respiratory mortality?
Lin, Hualiang; Ma, Wenjun; Qiu, Hong; Vaughn, Michael G; Nelson, Erik J; Qian, Zhengmin; Tian, Linwei
2016-09-01
Studies on health effects of air pollution often use daily mean concentration to estimate exposure while ignoring daily variations. This study examined the health effects of daily variation of PM2.5. We calculated daily mean and standard deviations of PM2.5 in Hong Kong between 1998 and 2011. We used a generalized additive model to estimate the association between respiratory mortality and daily mean and variation of PM2.5, as well as their interaction. We controlled for potential confounders, including temporal trends, day of the week, meteorological factors, and gaseous air pollutants. Both daily mean and standard deviation of PM2.5 were significantly associated with mortalities from overall respiratory diseases and pneumonia. Each 10 μg/m(3) increment in daily mean concentration at lag 2 day was associated with a 0.61% (95% CI: 0.19%, 1.03%) increase in overall respiratory mortality and a 0.67% (95% CI: 0.14%, 1.21%) increase in pneumonia mortality. And a 10 μg/m(3) increase in standard deviation at lag 1 day corresponded to a 1.40% (95% CI: 0.35%, 2.46%) increase in overall respiratory mortality, and a 1.80% (95% CI: 0.46%, 3.16%) increase in pneumonia mortality. We also observed a positive but non-significant synergistic interaction between daily mean and variation on respiratory mortality and pneumonia mortality. However, we did not find any significant association with mortality from chronic obstructive pulmonary diseases. Our study suggests that, besides mean concentration, the standard deviation of PM2.5 might be one potential predictor of respiratory mortality in Hong Kong, and should be considered when assessing the respiratory effects of PM2.5. Copyright © 2016 Elsevier Ltd. All rights reserved.
Complexities of follicle deviation during selection of a dominant follicle in Bos taurus heifers.
Ginther, O J; Baldrighi, J M; Siddiqui, M A R; Araujo, E R
2016-11-01
Follicle deviation during a follicular wave is a continuation in growth rate of the dominant follicle (F1) and decreased growth rate of the largest subordinate follicle (F2). The reliability of using an F1 of 8.5 mm to represent the beginning of expected deviation for experimental purposes during waves 1 and 2 (n = 26 per wave) was studied daily in heifers. Each wave was subgrouped as follows: standard subgroup (F1 larger than F2 for 2 days preceding deviation and F2 > 7.0 mm on the day of deviation), undersized subgroup (F2 did not attain 7.0 mm by the day of deviation), and switched subgroup (F2 larger than F1 at least once on the 2 days before or on the day of deviation). For each wave, mean differences in diameter between F1 and F2 changed abruptly at expected deviation in the standard subgroup but began 1 day before expected deviation in the undersized and switched subgroups. Concentrations of FSH in the wave-stimulating FSH surge and an increase in LH centered on expected deviation did not differ among subgroups. Results for each wave indicated that (1) expected deviation (F1, 8.5 mm) was a reliable representation of actual deviation in the standard subgroup but not in the undersized and switched subgroups; (2) concentrations of the gonadotropins normalized to expected deviation were similar among the three subgroups, indicating that the day of deviation was related to diameter of F1 and not F2; and (3) defining an expected day of deviation for experimental use should consider both diameter of F1 and the characteristics of deviation. Copyright © 2016 Elsevier Inc. All rights reserved.
McLain, B.J.
1993-01-01
Graphite furnace atomic absorption spectrophotometry is a sensitive, precise, and accurate method for the determination of chromium in natural water samples. The detection limit for this analytical method is 0.4 microg/L with a working linear limit of 25.0 microg/L. The precision at the detection limit ranges from 20 to 57 percent relative standard deviation (RSD) with an improvement to 4.6 percent RSD for concentrations more than 3 microg/L. Accuracy of this method was determined for a variety of reference standards that was representative of the analytical range. The results were within the established standard deviations. Samples were spiked with known concentrations of chromium with recoveries ranging from 84 to 122 percent. In addition, a comparison of data between graphite furnace atomic absorption spectrophotometry and direct-current plasma atomic emission spectrometry resulted in suitable agreement between the two methods, with an average deviation of +/- 2.0 microg/L throughout the analytical range.
Using an external gating signal to estimate noise in PET with an emphasis on tracer avid tumors
NASA Astrophysics Data System (ADS)
Schmidtlein, C. R.; Beattie, B. J.; Bailey, D. L.; Akhurst, T. J.; Wang, W.; Gönen, M.; Kirov, A. S.; Humm, J. L.
2010-10-01
The purpose of this study is to establish and validate a methodology for estimating the standard deviation of voxels with large activity concentrations within a PET image using replicate imaging that is immediately available for use in the clinic. To do this, ensembles of voxels in the averaged replicate images were compared to the corresponding ensembles in images derived from summed sinograms. In addition, the replicate imaging noise estimate was compared to a noise estimate based on an ensemble of voxels within a region. To make this comparison two phantoms were used. The first phantom was a seven-chamber phantom constructed of 1 liter plastic bottles. Each chamber of this phantom was filled with a different activity concentration relative to the lowest activity concentration with ratios of 1:1, 1:1, 2:1, 2:1, 4:1, 8:1 and 16:1. The second phantom was a GE Well-Counter phantom. These phantoms were imaged and reconstructed on a GE DSTE PET/CT scanner with 2D and 3D reprojection filtered backprojection (FBP), and with 2D- and 3D-ordered subset expectation maximization (OSEM). A series of tests were applied to the resulting images that showed that the region and replicate imaging methods for estimating standard deviation were equivalent for backprojection reconstructions. Furthermore, the noise properties of the FBP algorithms allowed scaling the replicate estimates of the standard deviation by a factor of 1/\\sqrt{N}, where N is the number of replicate images, to obtain the standard deviation of the full data image. This was not the case for OSEM image reconstruction. Due to nonlinearity of the OSEM algorithm, the noise is shown to be both position and activity concentration dependent in such a way that no simple scaling factor can be used to extrapolate noise as a function of counts. The use of the Well-Counter phantom contributed to the development of a heuristic extrapolation of the noise as a function of radius in FBP. In addition, the signal-to-noise ratio for high uptake objects was confirmed to be higher with backprojection image reconstruction methods. These techniques were applied to several patient data sets acquired in either 2D or 3D mode, with 18F (FLT and FDG). Images of the standard deviation and signal-to-noise ratios were constructed and the standard deviations of the tumors' uptake were determined. Finally, a radial noise extrapolation relationship deduced in this paper was applied to patient data.
Williams, Rachel E; Arabi, Mazdak; Loftis, Jim; Elmund, G Keith
2014-09-01
Implementation of numeric nutrient standards in Colorado has prompted a need for greater understanding of human impacts on ambient nutrient levels. This study explored the variability of annual nutrient concentrations due to upstream anthropogenic influences and developed a mathematical expression for the number of samples required to estimate median concentrations for standard compliance. A procedure grounded in statistical hypothesis testing was developed to estimate the number of annual samples required at monitoring locations while taking into account the difference between the median concentrations and the water quality standard for a lognormal population. For the Cache La Poudre River in northern Colorado, the relationship between the median and standard deviation of total N (TN) and total P (TP) concentrations and the upstream point and nonpoint concentrations and general hydrologic descriptors was explored using multiple linear regression models. Very strong relationships were evident between the upstream anthropogenic influences and annual medians for TN and TP ( > 0.85, < 0.001) and corresponding standard deviations ( > 0.7, < 0.001). Sample sizes required to demonstrate (non)compliance with the standard depend on the measured water quality conditions. When the median concentration differs from the standard by >20%, few samples are needed to reach a 95% confidence level. When the median is within 20% of the corresponding water quality standard, however, the required sample size increases rapidly, and hundreds of samples may be required. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Damrau, D.L.
1993-01-01
Increased awareness of the quality of water in the United States has led to the development of a method for determining low levels (0.2-5.0 microg/L) of silver in water samples. Use of graphite furnace atomic absorption spectrophotometry provides a sensitive, precise, and accurate method for determining low-level silver in samples of low ionic-strength water, precipitation water, and natural water. The minimum detection limit determined for low-level silver is 0.2 microg/L. Precision data were collected on natural-water samples and SRWS (Standard Reference Water Samples). The overall percent relative standard deviation for natural-water samples with silver concentrations more than 0.2 microg/L was less than 40 percent throughout the analytical range. For the SRWS with concentrations more than 0.2 microg/L, the overall percent relative standard deviation was less than 25 percent throughout the analytical range. The accuracy of the results was determined by spiking 6 natural-water samples with different known concentrations of the silver standard. The recoveries ranged from 61 to 119 percent at the 0.5-microg/L spike level. At the 1.25-microg/L spike level, the recoveries ranged from 92 to 106 percent. For the high spike level at 3.0 microg/L, the recoveries ranged from 65 to 113 percent. The measured concentrations of silver obtained from known samples were within the Branch of Quality Assurance accepted limits of 1 1/2 standard deviations on the basis of the SRWS program for Inter-Laboratory studies.
Catalytic determination of vanadium in water
Fishman, M. J.; Skougstad, M.W.
1964-01-01
A rapid, accurate, and sensitive spectrophotometric method for the quantitative determination of trace amounts of vanadium in water is based on the catalytic effect of vanadium on the rate of oxidation of gallic acid by persulfate in acid solution. Under given conditions of concentrations of reactants, temperature, and reaction time, the extent of oxidation of gallic acid is proportional to the concentration of vanadium present. Vanadium is determined by measuring the absorbance of the sample at 415 m?? and comparison with standard solutions treated in an identical manner. Concentrations in the range of from 0.1 to 8.0 ??g. per liter may be determined with a standard deviation of 0.2 or less. By reducing the reaction time, the method may be extended to cover the range from 1 to 100 ??g. with a standard deviation of 0.8 or less. Several substances interfere, including chloride above 100 p.p.m., and bromide and iodide in much lower concentrations. Interference from the halides is eliminated or minimized by the addition of mercuric nitrate solution. Most other substances do not interfere at the concentration levels at which they commonly occur in natural waters.
[Determination of acetochlor and oxyfluorfen by capillary gas chromatography].
Xiang, Wen-Sheng; Wang, Xiang-Jing; Wang, Jing; Wang, Qing
2002-09-01
A method is described for the determination of acetochlor and oxyfluorfen by capillary gas chromatography with FID and an SE-30 capillary column (60 m x 0.53 mm i. d., 1.5 microm), using dibutyl phthalate as the internal standard. The standard deviations for acetochlor and oxyfluorfen concentration(mass fraction) were 0.44% and 0.47% respectively. The relative standard deviations for acetochlor and oxyfluorfen were 0.79% and 0.88% and the average recoveries for acetochlor and oxyfluorfen were 99.3% and 101.1% respectively. The method is simple, rapid and accurate.
NASA Astrophysics Data System (ADS)
Wang, J.; Shi, M.; Zheng, P.; Xue, Sh.; Peng, R.
2018-03-01
Laser-induced breakdown spectroscopy has been applied for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens Maxim. f. biserrata Shan et Yuan used in traditional Chinese medicine. Ca II 317.993 nm, Mg I 517.268 nm, and K I 769.896 nm spectral lines have been chosen to set up calibration models for the analysis using the external standard and artificial neural network methods. The linear correlation coefficients of the predicted concentrations versus the standard concentrations of six samples determined by the artificial neural network method are 0.9896, 0.9945, and 0.9911 for Ca, Mg, and K, respectively, which are better than for the external standard method. The artificial neural network method also gives better performance comparing with the external standard method for the average and maximum relative errors, average relative standard deviations, and most maximum relative standard deviations of the predicted concentrations of Ca, Mg, and K in the six samples. Finally, it is proved that the artificial neural network method gives better performance compared to the external standard method for the quantitative analysis of Ca, Mg, and K in the roots of Angelica pubescens.
Yang, Ting-Wen; Zhao, Chao; Fan, Yong; Qi, Lian-Wen; Li, Ping
2015-10-10
Single standard to determine multi-components (SSDMC) is a practical pattern for quality evaluation of herbal medicines (HMs). However, it remains challenging because of potential inconsistency of relative response factors (RRF) on different instruments. In this work, the effects of two key roles, i.e., ultraviolet (UV) wavelength and standard solution concentrations, on reproducibility of RRF were investigated. The effect of UV wavelength on reproducibility of RRF was studied by plotting the relationship of the peak area ratios (internal standard vs analyte) to wavelengths. The preferable wavelength should be set at the flat parts of the curve. Optimized 300 nm produced a 0.38% RSD for emodin/emodin-8-O-β-D-glucopyranoside on five instruments, much lower than 2.80% obtained from the maximum wavelength at 290 nm. Next, the effects of standard solution concentrations of emodin on its response factor (RF) were investigated. For one single point method, low concentration less than 49 b/k resulted in significant variations in RF. For emodin, when the concentration is higher than 7.00 μg mL(-1), a low standard deviation (SD) value at 0.13 was obtained, while lower than 7.00 μg mL(-1), a high SD at 3.71 was obtained. The developed SSDMC method was then applied to determination of target components in 10 Polygonum cuspidatum samples and showed comparable accuracy to conventional calibration methods with deviation less than 1%. Copyright © 2015 Elsevier B.V. All rights reserved.
Buchdahl, R.; Parker, A.; Stebbings, T.; Babiker, A.
1996-01-01
OBJECTIVE--To examine the association between the air pollutants ozone, sulphur dioxide, and nitrogen dioxide and the incidence of acute childhood wheezy episodes. DESIGN--Prospective observational study over one year. SETTING--District general hospital. SUBJECTS--1025 children attending the accident and emergency department with acute wheezy episodes; 4285 children with other conditions as the control group. MAIN OUTCOME MEASURES--Daily incidence of acute wheezy episodes. RESULTS--After seasonal adjustment, day to day variations in daily average concentrations of ozone and sulphur dioxide were found to have significant associations with the incidence of acute wheezy episodes. The strongest association was with ozone, for which a non-linear U shaped relation was seen. In terms of the incidence rate ratio (1 at a mean 24 hour ozone concentration of 40 microg/m3 (SD=19.1)), children were more likely to attend when the concentration was two standard deviations below the mean (incidence rate ratio=3.01; 95% confidence interval 2.17 to 4.18) or two standard deviations above the mean (1.34; 1.09 to 1.66). Sulphur dioxide had a weaker log-linear relation with incidence (1.12; 1.05 to 1.19 for each standard deviation (14.1) increase in sulphur dioxide concentration). Further adjustment for temperature and wind speed did not significantly alter these associations. CONCLUSIONS--Independent of season, temperature, and wind speed, fluctuations in concentrations of atmospheric ozone and sulphur dioxide are strongly associated with patterns of attendance at accident and emergency departments for acute childhood wheezy episodes. A critical ozone concentration seems to exist in the atmosphere above or below which children are more likely to develop symptoms. PMID:8597731
Concentration sensor based on a tilted fiber Bragg grating for anions monitoring
NASA Astrophysics Data System (ADS)
Melo, L. B.; Rodrigues, J. M. M.; Farinha, A. S. F.; Marques, C. A.; Bilro, L.; Alberto, N.; Tomé, J. P. C.; Nogueira, R. N.
2014-08-01
The ubiquity and importance of anions in many crucial roles accounts for the current high interest in the design and preparation of effective sensors for these species. Therefore, a tilted fiber Bragg grating sensor was fabricated to investigate individual detection of different anion concentrations in ethyl acetate, namely acetate, fluoride and chloride. The influence of the refractive index on the transmission spectrum of a tilted fiber Bragg grating was determined by developing a new demodulation method. This is based on the calculation of the standard deviation between the cladding modes of the transmission spectrum and its smoothing function. The standard deviation method was used to monitor concentrations of different anions. The sensor resolution obtained for the anion acetate, fluoride and chloride is 79 × 10-5 mol/dm3, 119 × 10-5 mol/dm3 and 78 × 10-5 mol/dm3, respectively, within the concentration range of (39-396) × 10-5 mol/dm3.
Hendriks, A Jan; Awkerman, Jill A; de Zwart, Dick; Huijbregts, Mark A J
2013-11-01
While variable sensitivity of model species to common toxicants has been addressed in previous studies, a systematic analysis of inter-species variability for different test types, modes of action and species is as of yet lacking. Hence, the aim of the present study was to identify similarities and differences in contaminant levels affecting cold-blooded and warm-blooded species administered via different routes. To that end, data on lethal water concentrations LC50, tissue residues LR50 and oral doses LD50 were collected from databases, each representing the largest of its kind. LC50 data were multiplied by a bioconcentration factor (BCF) to convert them to internal concentrations that allow for comparison among species. For each endpoint data set, we calculated the mean and standard deviation of species' lethal level per compound. Next, the means and standard deviations were averaged by mode of action. Both the means and standard deviations calculated depended on the number of species tested, which is at odds with quality standard setting procedures. Means calculated from (BCF) LC50, LR50 and LD50 were largely similar, suggesting that different administration routes roughly yield similar internal levels. Levels for compounds interfering biochemically with elementary life processes were about one order of magnitude below that of narcotics disturbing membranes, and neurotoxic pesticides and dioxins induced death in even lower amounts. Standard deviations for LD50 data were similar across modes of action, while variability of LC50 values was lower for narcotics than for substances with a specific mode of action. The study indicates several directions to go for efficient use of available data in risk assessment and reduction of species testing. Copyright © 2013 Elsevier Inc. All rights reserved.
Yarazavi, Mina; Noroozian, Ebrahim
2018-02-13
A novel sol-gel coating on a stainless-steel fiber was developed for the first time for the headspace solid-phase microextraction and determination of α-bisabolol with gas chromatography and flame ionization detection. The parameters influencing the efficiency of solid-phase microextraction process, such as extraction time and temperature, pH, and ionic strength, were optimized by the experimental design method. Under optimized conditions, the linear range was between 0.0027 and 100 μg/mL. The relative standard deviations determined at 0.01 and 1.0 μg/mL concentration levels (n = 3), respectively, were as follows: intraday relative standard deviations 3.4 and 3.3%; interday relative standard deviations 5.0 and 4.3%; and fiber-to-fiber relative standard deviations 6.0 and 3.5%. The relative recovery values were 90.3 and 101.4% at 0.01 and 1.0 μg/mL spiking levels, respectively. The proposed method was successfully applied to various real samples containing α-bisabolol. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Conrads, P.A.; Smith, P.A.
1996-01-01
The one-dimensional, unsteady-flow model, BRANCH, and the Branched Lagrangian Transport Model (BLTM) were calibrated and validated for the Cooper and Wando Rivers near Charleston, South Carolina. Data used to calibrate the BRANCH model included water-level data at four locations on the Cooper River and two locations on the Wando River, measured tidal-cycle streamflows at five locations on the Wando River, and simulated tidal-cycle streamflows (using an existing validated BRANCH model of the Cooper River) for four locations on the Cooper River. The BRANCH model was used to generate the necessary hydraulic data used in the BLTM model. The BLTM model was calibrated and validated using time series of salinity concentrations at two locations on the Cooper River and at two locations on the Wando River. Successful calibration and validation of the BRANCH and BLTM models to water levels, stream flows, and salinity were achieved after applying a positive 0.45 foot datum correction to the downstream boundary. The sensitivity of the simulated salinity concentrations to changes in the downstream gage datum, channel geometry, and roughness coefficient in the BRANCH model, and to the dispersion factor in the BLTM model was evaluated. The simulated salinity concentrations were most sensitive to changes in the downstream gage datum. A decrease of 0.5 feet in the downstream gage datum increased the simulated 3-day mean salinity concentration by 107 percent (12.7 to 26.3 parts per thousand). The range of the salinity concentration went from a tidal oscillation with a standard deviation of 3.9 parts per thousand to a nearly constant concentration with a standard deviation of 0.0 parts per thousand. An increase in the downstream gage datum decreased the simulated 3-day mean salinity concentration by 47 percent (12.7 to 6.7 parts per thousand) and decreased the standard deviation from 3.9 to 3.4 parts per thousand.
Wang, Yi-Ya; Zhan, Xiu-Chun
2014-04-01
Evaluating uncertainty of analytical results with 165 geological samples by polarized dispersive X-ray fluorescence spectrometry (P-EDXRF) has been reported according to the internationally accepted guidelines. One hundred sixty five pressed pellets of similar matrix geological samples with reliable values were analyzed by P-EDXRF. These samples were divided into several different concentration sections in the concentration ranges of every component. The relative uncertainties caused by precision and accuracy of 27 components were evaluated respectively. For one element in one concentration, the relative uncertainty caused by precision can be calculated according to the average value of relative standard deviation with different concentration level in one concentration section, n = 6 stands for the 6 results of one concentration level. The relative uncertainty caused by accuracy in one concentration section can be evaluated by the relative standard deviation of relative deviation with different concentration level in one concentration section. According to the error propagation theory, combining the precision uncertainty and the accuracy uncertainty into a global uncertainty, this global uncertainty acted as method uncertainty. This model of evaluating uncertainty can solve a series of difficult questions in the process of evaluating uncertainty, such as uncertainties caused by complex matrix of geological samples, calibration procedure, standard samples, unknown samples, matrix correction, overlap correction, sample preparation, instrument condition and mathematics model. The uncertainty of analytical results in this method can act as the uncertainty of the results of the similar matrix unknown sample in one concentration section. This evaluation model is a basic statistical method owning the practical application value, which can provide a strong base for the building of model of the following uncertainty evaluation function. However, this model used a lot of samples which cannot simply be applied to other types of samples with different matrix samples. The number of samples is too large to adapt to other type's samples. We will strive for using this study as a basis to establish a reasonable basis of mathematical statistics function mode to be applied to different types of samples.
Evaluation on determination of iodine in coal by energy dispersive X-ray fluorescence
Wang, B.; Jackson, J.C.; Palmer, C.; Zheng, B.; Finkelman, R.B.
2005-01-01
A quick and inexpensive method of relative high iodine determination from coal samples was evaluated. Energy dispersive X-ray fluorescence (EDXRF) provided a detection limit of about 14 ppm (3 times of standard deviations of the blank sample), without any complex sample preparation. An analytical relative standard deviation of 16% was readily attainable for coal samples. Under optimum conditions, coal samples with iodine concentrations higher than 5 ppm can be determined using this EDXRF method. For the time being, due to the general iodine concentrations of coal samples lower than 5 ppm, except for some high iodine content coal, this method can not effectively been used for iodine determination. More work needed to meet the requirement of determination of iodine from coal samples for this method. Copyright ?? 2005 by The Geochemical Society of Japan.
Time Resolved Filtered Rayleigh Scattering Measurement of a Centrifugally Loaded Buoyant Jet
2011-03-01
61 Figure 51. Sample CO2 Process Data: (a) Percent Concentration, ( b ) Concentration Profile, (c) Jet’s Trajectory...Standard Deviation and ( b ) Mean ................................. 64 Figure 54. Rayleigh-Scattering Signal Due to Air Associated with the First and...Second Laser Beams: (a) Raw Images and ( b ) Intensity Counts ........................................................................ 65 Figure 55
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lin, Guangxing; Qian, Yun; Yan, Huiping
One limitation of most global climate models (GCMs) is that with the horizontal resolutions they typically employ, they cannot resolve the subgrid variability (SGV) of clouds and aerosols, adding extra uncertainties to the aerosol radiative forcing estimation. To inform the development of an aerosol subgrid variability parameterization, here we analyze the aerosol SGV over the southern Pacific Ocean simulated by the high-resolution Weather Research and Forecasting model coupled to Chemistry. We find that within a typical GCM grid, the aerosol mass subgrid standard deviation is 15% of the grid-box mean mass near the surface on a 1 month mean basis.more » The fraction can increase to 50% in the free troposphere. The relationships between the sea-salt mass concentration, meteorological variables, and sea-salt emission rate are investigated in both the clear and cloudy portion. Under clear-sky conditions, marine aerosol subgrid standard deviation is highly correlated with the standard deviations of vertical velocity, cloud water mixing ratio, and sea-salt emission rates near the surface. It is also strongly connected to the grid box mean aerosol in the free troposphere (between 2 km and 4 km). In the cloudy area, interstitial sea-salt aerosol mass concentrations are smaller, but higher correlation is found between the subgrid standard deviations of aerosol mass and vertical velocity. Additionally, we find that decreasing the model grid resolution can reduce the marine aerosol SGV but strengthen the correlations between the aerosol SGV and the total water mixing ratio (sum of water vapor, cloud liquid, and cloud ice mixing ratios).« less
Ackerman, L.K.; Schwindt, A.R.; Simonich, S.L.M.; Koch, D.C.; Blett, T.F.; Schreck, C.B.; Kent, M.L.; Landers, D.H.
2008-01-01
Concentrations of polybrominated diphenyl ethers (PBDEs), pesticides, polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons were measured in 136 fish from 14 remote lakes in 8 western U.S. National Parks/Preserves between 2003 and 2005 and compared to human and wildlife contaminant health thresholds. A sensitive (median detection limit, -18 pg/g wet weight), efficient (61% recovery at 8 ng/g), reproducible (4.1% relative standard deviation (RSD)), and accurate (7% deviation from standard reference material (SRM)) analytical method was developed and validated for these analyses. Concentrations of PCBs, hexachlorobenzene, hexachlorocyclohexanes, DDTs, and chlordanes in western U.S. fish were comparable to or lower than mountain fish recently collected from Europe, Canada, and Asia. Dieldrin and PBDE concentrations were higher than recent measurements in mountain fish and Pacific Ocean salmon. Concentrations of most contaminants in western U.S. fish were 1-6 orders of magnitude below calculated recreational fishing contaminant health thresholds. However, lake average contaminant concentrations in fish exceeded subsistence fishing cancer thresholds in 8 of 14 lakes and wildlife contaminant health thresholds for piscivorous birds in 1of 14 lakes. These results indicate that atmospherically deposited organic contaminants can accumulate in high elevation fish, reaching concentrations relevant to human and wildlife health. ?? 2008 American Chemical Society.
Mercury Human Exposure in Populations Living Around Lake Tana (Ethiopia).
Habiba, G; Abebe, G; Bravo, Andrea G; Ermias, D; Staffan, Ǻ; Bishop, K
2017-02-01
A survey carried out in Lake Tana in 2015 found that Hg levels in some fish species exceeded internationally accepted safe levels for fish consumption. The current study assesses human exposure to Hg through fish consumption around the Lake Tana. Of particular interest was that a dietary intake of fishes is currently a health risk for Bihar Dar residents and anglers. Hair samples were collected from three different groups: anglers, college students and teachers, and daily laborers. A questionary includes gender, age, weight, activity. Frequency of fish consumption and origin of the eaten fish were completed by each participant. Mercury concentrations in hair were significantly higher (P value <0.05) for anglers (mean ± standard deviation 0.120 ± 0.199 μg/g) than college students (mean ± standard deviation 0.018 ± 0.039 μg/g) or daily workers (mean ± standard deviation 16 ± 9.5 ng/g). Anglers consumed fish more often than daily workers and college group. Moreover, there was also a strong correlation (P value <0.05) between the logarithms of total mercury and age associated with mercury concentration in scalp hair. Mercury concentrations in the hair of men were on average twice the value of the women. Also, users of skin lightening soap on a daily basis had 2.5 times greater mercury in scalp hair than non-users. Despite the different sources of mercury exposure mentioned above, the mercury concentrations of the scalp hair of participants of this study were below levels deemed to pose a threat to health.
Cruise Summary of WHP P6, A10, I3 and I4 Revisits in 2003
NASA Astrophysics Data System (ADS)
Kawano, T.; Uchida, H.; Schneider, W.; Kumamoto, Y.; Nishina, A.; Aoyama, M.; Murata, A.; Sasaki, K.; Yoshikawa, Y.; Watanabe, S.; Fukasawa, M.
2004-12-01
Japan Agency for Marin-Earth Science and Technology (JAMSTEC) conducted a research cruise to round in the southern hemisphere by R/V Mirai. In this presentation, we introduce an outline of the cruise and data quality obtained during the cruise. The cruise started on Aug. 3, 2003 in Brisbane, Australia and sailed eastward until it reached Fremantle, Australia on Feb. 19, 2004. It contained six legs and legs 1, 2, 4 and 5 were revisits of WOCE Hydrographic Program (WHP) sections P6W, P6E, A10 and I3/I4, respectively. The sections consisted of about 500 hydrographic stations in total. On each station, CTD profiles and up to 36 water samples by 12L Niskin-X bottles were taken from the surface to within 10 m of the bottom. Water samples were analyzed at every station for salinity, dissolved oxygen (DO), and nutrients and at alternate stations for concentration of freons, dissolved inorganic carbon (CT), total alkalinity (AT), pH, and so on. Approximately 17,000 samples were obtained for salinity. The standard seawater was measured repeatedly to estimate the uncertainty caused by the setting and stability of the salinometer. The standard deviation of 699 repeated runs of standard seawater was 0.0002 in salinity. Replicate samples, which are a pair of samples drawn from the same Niskin bottle to different sample bottles, were taken to evaluate the overall uncertainty. The standard deviation of absolute differences of 2,769 replicates was also 0.0002 in salinity. For DO, about 13,400 samples were obtained. The analysis was made by a photometric titration technique. The reproducibility estimated from the absolute standard deviation of 1,625 replicates was about 0.09 umol/kg. CTD temperature was calibrated against a deep ocean standards thermometer (SBE35) which was attached to the CTD using a polynomial expression Tcal = T - (a +b*P + c*t), where Tcal is calibrated temperature, T is CTD temperature, P is CTD pressure and t is time. Calibration coefficients, a, b and c, were determined for each station by minimizing the sum of absolute deviation from SBE35 temperature below 2,000dbar. CTD salinity and DO were fitted to values obtained by sampled water analysis using similar polynomials. These corrections yielded deviations of about 0.0002 K in temperature, 0.0003 in salinity and 0.6 umol/kg in DO. Nutrients analyses were accomplished on 16,000 samples using the reference material of nutrients in seawater (RMNS). To establish the traceability and to get higher quality data, 500 bottles of RMNS from the same lot and 150 sets of RMNSs were used. The precisions of phosphate, nitrate and silicate measurements were 0.18 %, 0.17 % and 0.16 % in terms of median of those at 493 stations, respectively. The nutrients concentrations could be expressed with uncertainties explicitly because of the repeated runs of RMNSs. All the analyses for the CO{2}-system parameters in water columns were finished onboard. Analytical precisions of CT, AT and pH were estimated to be \\sim1.0 umol/kg, \\sim2.0 umol/kg, and \\sim7*10-4 pH unit, respectively. Approximately 6,300 samples were obtained for CFC-11 and CFC-12. The concentrations were determined with an electron capture detector - gas chromatograph (ECD-GC) attached the purge and trapping system. The reproducibility estimated from the absolute standard deviation of 365 replicates was less than 1% with respect to the surface concentrations.
Clinical application of Chamomilla recutita in phlebitis: dose response curve study.
Reis, Paula Elaine Diniz Dos; Carvalho, Emilia Campos de; Bueno, Paula Carolina Pires; Bastos, Jairo Kenupp
2011-01-01
This experimental and dose-response curve study aimed to carry out the quality control of the Chamomilla recutita sample, as well as to estimate the ideal dose, for anti-inflammatory effect, of the extract of its capitula, in patients with phlebitis due to peripheral intravenous infusion of antineoplastic chemotherapy and to evaluate the toxicity of this extract in human beings. The therapeutic efficacy, concerning the anti-inflammatory potential, of different doses of Chamomilla recutita extract were analyzed and compared in 25 patients. The time of regression of phlebitis was shorter for groups with 2.5% concentration (mean=29.2h, standard deviation = 8.98) and 5% concentration (mean = 38.8h, standard deviation = 17.47). Local toxicity was almost not observed. This research contributes to the innovation of the nursing clinical practice, since it suggests an alternative for the treatment of phlebitis through the clinical use of phytotherapeutic drugs.
Shen, Meiyu; Russek-Cohen, Estelle; Slud, Eric V
2016-08-12
Bioequivalence (BE) studies are an essential part of the evaluation of generic drugs. The most common in vivo BE study design is the two-period two-treatment crossover design. AUC (area under the concentration-time curve) and Cmax (maximum concentration) are obtained from the observed concentration-time profiles for each subject from each treatment under each sequence. In the BE evaluation of pharmacokinetic crossover studies, the normality of the univariate response variable, e.g. log(AUC) 1 or log(Cmax), is often assumed in the literature without much evidence. Therefore, we investigate the distributional assumption of the normality of response variables, log(AUC) and log(Cmax), by simulating concentration-time profiles from two-stage pharmacokinetic models (commonly used in pharmacokinetic research) for a wide range of pharmacokinetic parameters and measurement error structures. Our simulations show that, under reasonable distributional assumptions on the pharmacokinetic parameters, log(AUC) has heavy tails and log(Cmax) is skewed. Sensitivity analyses are conducted to investigate how the distribution of the standardized log(AUC) (or the standardized log(Cmax)) for a large number of simulated subjects deviates from normality if distributions of errors in the pharmacokinetic model for plasma concentrations deviate from normality and if the plasma concentration can be described by different compartmental models.
Automation of the anthrone assay for carbohydrate concentration determinations.
Turula, Vincent E; Gore, Thomas; Singh, Suddham; Arumugham, Rasappa G
2010-03-01
Reported is the adaptation of a manual polysaccharide assay applicable for glycoconjugate vaccines such as Prevenar to an automated liquid handling system (LHS) for improved performance. The anthrone assay is used for carbohydrate concentration determinations and was scaled to the microtiter plate format with appropriate mixing, dispensing, and measuring operations. Adaptation and development of the LHS platform was performed with both dextran polysaccharides of various sizes and pneumococcal serotype 6A polysaccharide (PnPs 6A). A standard plate configuration was programmed such that the LHS diluted both calibration standards and a test sample multiple times with six replicate preparations per dilution. This extent of replication minimized the effect of any single deviation or delivery error that might have occurred. Analysis of the dextran polymers ranging in size from 214 kDa to 3.755 MDa showed that regardless of polymer chain length the hydrolysis was complete, as evident by uniform concentration measurements. No plate positional absorbance bias was observed; of 12 plates analyzed to examine positional bias the largest deviation observed was 0.02% percent relative standard deviation (%RSD). The high purity dextran also afforded the opportunity to assess LHS accuracy; nine replicate analyses of dextran yielded a mean accuracy of 101% recovery. As for precision, a total of 22 unique analyses were performed on a single lot of PnPs 6A, and the resulting variability was 2.5% RSD. This work demonstrated the capability of a LHS to perform the anthrone assay consistently and a reduced assay cycle time for greater laboratory capacity.
Evaluation of methods for measuring particulate matter emissions from gas turbines.
Petzold, Andreas; Marsh, Richard; Johnson, Mark; Miller, Michael; Sevcenco, Yura; Delhaye, David; Ibrahim, Amir; Williams, Paul; Bauer, Heidi; Crayford, Andrew; Bachalo, William D; Raper, David
2011-04-15
The project SAMPLE evaluated methods for measuring particle properties in the exhaust of aircraft engines with respect to the development of standardized operation procedures for particulate matter measurement in aviation industry. Filter-based off-line mass methods included gravimetry and chemical analysis of carbonaceous species by combustion methods. Online mass methods were based on light absorption measurement or used size distribution measurements obtained from an electrical mobility analyzer approach. Number concentrations were determined using different condensation particle counters (CPC). Total mass from filter-based methods balanced gravimetric mass within 8% error. Carbonaceous matter accounted for 70% of gravimetric mass while the remaining 30% were attributed to hydrated sulfate and noncarbonaceous organic matter fractions. Online methods were closely correlated over the entire range of emission levels studied in the tests. Elemental carbon from combustion methods and black carbon from optical methods deviated by maximum 5% with respect to mass for low to medium emission levels, whereas for high emission levels a systematic deviation between online methods and filter based methods was found which is attributed to sampling effects. CPC based instruments proved highly reproducible for number concentration measurements with a maximum interinstrument standard deviation of 7.5%.
USDA-ARS?s Scientific Manuscript database
Our objective was to determine the effect of feeding diets with different forage to concentrate ratios (F:C) on performance and methane (CH4) emission from lactating dairy cows. Eight multiparous Holstein cows (means ± standard deviation: 620 ± 38 kg of body weight (BW); 41 ± 34 days in milk (DIM)) ...
Sampling for mercury at subnanogram per litre concentrations for load estimation in rivers
Colman, J.A.; Breault, R.F.
2000-01-01
Estimation of constituent loads in streams requires collection of stream samples that are representative of constituent concentrations, that is, composites of isokinetic multiple verticals collected along a stream transect. An all-Teflon isokinetic sampler (DH-81) cleaned in 75??C, 4 N HCl was tested using blank, split, and replicate samples to assess systematic and random sample contamination by mercury species. Mean mercury concentrations in field-equipment blanks were low: 0.135 ng??L-1 for total mercury (??Hg) and 0.0086 ng??L-1 for monomethyl mercury (MeHg). Mean square errors (MSE) for ??Hg and MeHg duplicate samples collected at eight sampling stations were not statistically different from MSE of samples split in the laboratory, which represent the analytical and splitting error. Low fieldblank concentrations and statistically equal duplicate- and split-sample MSE values indicate that no measurable contamination was occurring during sampling. Standard deviations associated with example mercury load estimations were four to five times larger, on a relative basis, than standard deviations calculated from duplicate samples, indicating that error of the load determination was primarily a function of the loading model used, not of sampling or analytical methods.
Dispersion in Rectangular Networks: Effective Diffusivity and Large-Deviation Rate Function
NASA Astrophysics Data System (ADS)
Tzella, Alexandra; Vanneste, Jacques
2016-09-01
The dispersion of a diffusive scalar in a fluid flowing through a network has many applications including to biological flows, porous media, water supply, and urban pollution. Motivated by this, we develop a large-deviation theory that predicts the evolution of the concentration of a scalar released in a rectangular network in the limit of large time t ≫1 . This theory provides an approximation for the concentration that remains valid for large distances from the center of mass, specifically for distances up to O (t ) and thus much beyond the O (t1 /2) range where a standard Gaussian approximation holds. A byproduct of the approach is a closed-form expression for the effective diffusivity tensor that governs this Gaussian approximation. Monte Carlo simulations of Brownian particles confirm the large-deviation results and demonstrate their effectiveness in describing the scalar distribution when t is only moderately large.
Bekiroglu, Somer; Myrberg, Olle; Ostman, Kristina; Ek, Marianne; Arvidsson, Torbjörn; Rundlöf, Torgny; Hakkarainen, Birgit
2008-08-05
A 1H-nuclear magnetic resonance (NMR) spectroscopy method for quantitative determination of benzethonium chloride (BTC) as a constituent of grapefruit seed extract was developed. The method was validated, assessing its specificity, linearity, range, and precision, as well as accuracy, limit of quantification and robustness. The method includes quantification using an internal reference standard, 1,3,5-trimethoxybenzene, and regarded as simple, rapid, and easy to implement. A commercial grapefruit seed extract was studied and the experiments were performed on spectrometers operating at two different fields, 300 and 600 MHz for proton frequencies, the former with a broad band (BB) probe and the latter equipped with both a BB probe and a CryoProbe. The concentration average for the product sample was 78.0, 77.8 and 78.4 mg/ml using the 300 BB probe, the 600MHz BB probe and CryoProbe, respectively. The standard deviation and relative standard deviation (R.S.D., in parenthesis) for the average concentrations was 0.2 (0.3%), 0.3 (0.4%) and 0.3mg/ml (0.4%), respectively.
Wilson, Walter B; Costa, Andréia A; Wang, Huiyong; Dias, José A; Dias, Sílvia C L; Campiglia, Andres D
2012-07-06
The analytical performance of BEA - a commercial zeolite - is evaluated for the pre-concentration of fifteen Environmental Protection Agency - polycyclic aromatic hydrocarbons and their subsequent HPLC analysis in tap and lake water samples. The pre-concentration factors obtained with BEA have led to a method with excellent analytical figures of merit. One milliliter aliquots were sufficient to obtain excellent precision of measurements at the parts-per-trillion concentration level with relative standard deviations varying from 4.1% (dibenzo[a,h]anthracene) to 13.4% (pyrene). The limits of detection were excellent as well and varied between 1.1 (anthracene) and 49.9 ng L(-1) (indeno[1,2,3-cd]pyrene). The recovery values of all the studied compounds meet the criterion for regulated polycyclic aromatic hydrocarbons, which mandates relative standard deviations equal or lower than 25%. The small volume of organic solvents (100 μL per sample) and amount of BEA (2 mg per sample) makes sample pre-concentration environmentally friendly and cost effective. The extraction procedure is well suited for numerous samples as the small working volume (1 mL) facilitates the implementation of simultaneous sample extraction. These are attractive features when routine monitoring of numerous samples is contemplated. Copyright © 2012 Elsevier B.V. All rights reserved.
A New Approach to Extract Forest Water Use Efficiency from Eddy Covariance Data
NASA Astrophysics Data System (ADS)
Scanlon, T. M.; Sulman, B. N.
2016-12-01
Determination of forest water use efficiency (WUE) from eddy covariance data typically involves the following steps: (a) estimating gross primary productivity (GPP) from direct measurements of net ecosystem exchange (NEE) by extrapolating nighttime ecosystem respiration (ER) to daytime conditions, and (b) assuming direct evaporation (E) is minimal several days after rainfall, meaning that direct measurements of evapotranspiration (ET) are identical to transpiration (T). Both of these steps could lead to errors in the estimation of forest WUE. Here, we present a theoretical approach for estimating WUE through the analysis of standard eddy covariance data, which circumvents these steps. Only five statistics are needed from the high-frequency time series to extract WUE: CO2 flux, water vapor flux, standard deviation in CO2 concentration, standard deviation in water vapor concentration, and the correlation coefficient between CO2 and water vapor concentration for each half-hour period. The approach is based on the assumption that stomatal fluxes (i.e. photosynthesis and transpiration) lead to perfectly negative correlations and non-stomatal fluxes (i.e. ecosystem respiration and direct evaporation) lead to perfectly positive correlations within the CO2 and water vapor high frequency time series measured above forest canopies. A mathematical framework is presented, followed by a proof of concept using eddy covariance data and leaf-level measurements of WUE.
Improved thermal conductivity of TiO2-SiO2 hybrid nanofluid in ethylene glycol and water mixture
NASA Astrophysics Data System (ADS)
Hamid, K. A.; Azmi, W. H.; Nabil, M. F.; Mamat, R.
2017-10-01
The need to study hybrid nanofluid properties such as thermal conductivity has increased recently in order to provide better understanding on nanofluid thermal properties and behaviour. Due to its ability to improve heat transfer compared to conventional heat transfer fluids, nanofluids as a new coolant fluid are widely investigated. This paper presents the thermal conductivity of TiO2-SiO2 nanoparticles dispersed in ethylene glycol (EG)-water. The TiO2-SiO2 hybrid nanofluids is measured for its thermal conductivity using KD2 Pro Thermal Properties Analyzer for concentration ranging from 0.5% to 3.0% and temperature of 30, 50 and 70°C. The results show that the increasing in concentration and temperature lead to enhancement in thermal conductivity at range of concentration studied. The maximum enhancement is found to be 22.1% at concentration 3.0% and temperature 70°C. A new equation is proposed based on the experiment data and found to be in good agreement where the average deviation (AD), standard deviation (SD) and maximum deviation (MD) are 1.67%, 1.66% and 5.13%, respectively.
Resistance Training Increases the Variability of Strength Test Scores
2009-06-08
standard deviations for pretest and posttest strength measurements. This information was recorded for every strength test used in a total of 377 samples...significant if the posttest standard deviation consistently was larger than the pretest standard deviation. This condition could be satisfied even if...the difference in the standard deviations was small. For example, the posttest standard deviation might be 1% larger than the pretest standard
Quan, Hui; Zhang, Ji
2003-09-15
Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.
Kim, Younggy; Walker, W Shane; Lawler, Desmond F
2012-05-01
In electrodialysis desalination, the boundary layer near ion-exchange membranes is the limiting region for the overall rate of ionic separation due to concentration polarization over tens of micrometers in that layer. Under high current conditions, this sharp concentration gradient, creating substantial ionic diffusion, can drive a preferential separation for certain ions depending on their concentration and diffusivity in the solution. Thus, this study tested a hypothesis that the boundary layer affects the competitive transport between di- and mono-valent cations, which is known to be governed primarily by the partitioning with cation-exchange membranes. A laboratory-scale electrodialyzer was operated at steady state with a mixture of 10mM KCl and 10mM CaCl(2) at various flow rates. Increased flows increased the relative calcium transport. A two-dimensional model was built with analytical solutions of the Nernst-Planck equation. In the model, the boundary layer thickness was considered as a random variable defined with three statistical parameters: mean, standard deviation, and correlation coefficient between the thicknesses of the two boundary layers facing across a spacer. Model simulations with the Monte Carlo method found that a greater calcium separation was achieved with a smaller mean, greater standard deviation, or more negative correlation coefficient. The model and experimental results were compared for the cationic transport number as well as the current and potential relationship. The mean boundary layer thickness was found to decrease from 40 to less than 10 μm as the superficial water velocity increased from 1.06 to 4.24 cm/s. The standard deviation was greater than the mean thickness at slower water velocities and smaller at faster water velocities. Copyright © 2012 Elsevier Ltd. All rights reserved.
Placencia, A M; Peeler, J T
1999-01-01
A collaborative study involving 11 laboratories was conducted to measure the microbial barrier effectiveness of porous medical packaging. Two randomly cut samples from each of 6 commercially available porous materials and one positive and one negative control were tested by one operator in each of 11 laboratories. Microbial barrier effectiveness was measured in terms of logarithm reduction value (LRV), which reflects the log10 microbial penetration of the material being tested. The logarithm of the final concentration is subtracted from that of the initial concentration to obtain the LRV. Thus the higher the LRV, the better the barrier. Repeatability standard deviations ranged from 6.42 to 16.40; reproducibility standard deviations ranged from 15.50 to 22.70. Materials B(53), C(50), D(CT), and E(45MF) differ significantly from the positive control. The microbial ranking of porous packaging materials (exposure chamber method), ASTM method, has been adopted First Action by AOAC INTERNATIONAL.
7 CFR 400.204 - Notification of deviation from standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...
NASA Astrophysics Data System (ADS)
Ohern, J.
2016-02-01
Marine mammals are generally located in areas of enhanced surface primary productivity, though they may forage much deeper within the water column and higher on the food chain. Numerous studies over the past several decades have utilized ocean color data from remote sensing instruments (CZCS, MODIS, and others) to asses both the quantity and time scales over which surface primary productivity relates to marine mammal distribution. In areas of sustained upwelling, primary productivity may essentially grow in the secondary levels of productivity (the zooplankton and nektonic species on which marine mammals forage). However, in many open ocean habitats a simple trophic cascade does not explain relatively short time lags between enhanced surface productivity and marine mammal presence. Other dynamic features that entrain prey or attract marine mammals may be responsible for the correlations between marine mammals and ocean color. In order to investigate these features, two MODIS (moderate imaging spectroradiometer) data products, the concentration as well as the standard deviation of surface chlorophyll were used in conjunction with marine mammal sightings collected within Ecuadorian waters. Time lags between enhanced surface chlorophyll and marine mammal presence were on the order of 2-4 weeks, however correlations were much stronger when the standard deviation of spatially binned images was used, rather than the chlorophyll concentrations. Time lags also varied between Balaenopterid and Odontocete cetaceans. Overall, the standard deviation of surface chlorophyll proved a useful tool for assessing potential relationships between marine mammal sightings and surface chlorophyll.
de Macedo, A. N.; Vicente, G. H. L.; Nogueira, A. R. A.
2010-01-01
A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography – mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L−1 and 0.02 mg kg−1, respectively. PMID:21165598
Ansermot, Nicolas; Rudaz, Serge; Brawand-Amey, Marlyse; Fleury-Souverain, Sandrine; Veuthey, Jean-Luc; Eap, Chin B
2009-08-01
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
The Standard Deviation of Launch Vehicle Environments
NASA Technical Reports Server (NTRS)
Yunis, Isam
2005-01-01
Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.
Viability of Commercially Available Bleach for Water Treatment in Developing Countries
2009-01-01
Treating household water with low-cost, widely available commercial bleach is recommended by some organizations to improve water quality and reduce disease in developing countries. I analyzed the chlorine concentration of 32 bleaches from 12 developing countries; the average error between advertised and measured concentration was 35% (range = –45%–100%; standard deviation = 40%). Because of disparities between advertised and actual concentration, the use of commercial bleach for water treatment in developing countries is not recommended without ongoing quality control testing. PMID:19762657
Viability of commercially available bleach for water treatment in developing countries.
Lantagne, Daniele S
2009-11-01
Treating household water with low-cost, widely available commercial bleach is recommended by some organizations to improve water quality and reduce disease in developing countries. I analyzed the chlorine concentration of 32 bleaches from 12 developing countries; the average error between advertised and measured concentration was 35% (range = -45%-100%; standard deviation = 40%). Because of disparities between advertised and actual concentration, the use of commercial bleach for water treatment in developing countries is not recommended without ongoing quality control testing.
Objective image characterization of a spectral CT scanner with dual-layer detector
NASA Astrophysics Data System (ADS)
Ozguner, Orhan; Dhanantwari, Amar; Halliburton, Sandra; Wen, Gezheng; Utrup, Steven; Jordan, David
2018-01-01
This work evaluated the performance of a detector-based spectral CT system by obtaining objective reference data, evaluating attenuation response of iodine and accuracy of iodine quantification, and comparing conventional CT and virtual monoenergetic images in three common phantoms. Scanning was performed using the hospital’s clinical adult body protocol. Modulation transfer function (MTF) was calculated for a tungsten wire and visual line pair targets were evaluated. Image noise power spectrum (NPS) and pixel standard deviation were calculated. MTF for monoenergetic images agreed with conventional images within 0.05 lp cm-1. NPS curves indicated that noise texture of 70 keV monoenergetic images is similar to conventional images. Standard deviation measurements showed monoenergetic images have lower noise except at 40 keV. Mean CT number and CNR agreed with conventional images at 75 keV. Measured iodine concentration agreed with true concentration within 6% for inserts at the center of the phantom. Performance of monoenergetic images at detector based spectral CT is the same as, or better than, that of conventional images. Spectral acquisition and reconstruction with a detector based platform represents the physical behaviour of iodine as expected and accurately quantifies the material concentration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colle, R.; Unterweger, M.P.; Hodge, P.A.
1996-01-01
As part of an international {sup 222}Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (blind) {sup 222}Rn concentrations that could be related to US national standards. The standardized sample additions were obtained with a calibrated {sup 226}Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized {sup 222}Rn activity concentrations for the intercomparisonmore » ranged from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3} (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6% to 13%. This paper describes the calibration and methodology for the standardized sample additions.« less
Collé, R.; Unterweger, M. P.; Hodge, P. A.; Hutchinson, J. M. R.
1996-01-01
As part of an international 222Rn measurement intercomparison conducted at Bermuda in October 1991, NIST provided standardized sample additions of known, but undisclosed (“blind”) 222Rn concentrations that could be related to U.S. national standards. The standardized sample additions were obtained with a calibrated 226Ra source and a specially-designed manifold used to obtain well-known dilution factors from simultaneous flow-rate measurements. The additions were introduced over sampling periods of several hours (typically 4 h) into a common streamline on a sampling tower used by the participating laboratories for their measurements. The standardized 222Rn activity concentrations for the intercomparison ranged from approximately 2.5 Bq · m−3 to 35 Bq · m−3 (of which the lower end of this range approached concentration levels for ambient Bermudian air) and had overall uncertainties, approximating a 3 standard deviation uncertainty interval, of about 6 % to 13 %. This paper describes the calibration and methodology for the standardized sample additions. PMID:27805090
Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay
2007-11-01
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively.
7 CFR 400.174 - Notification of deviation from financial standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...
NASA Astrophysics Data System (ADS)
Bala, Rajni; Mittal, Sherry; Sharma, Rohit K.; Wangoo, Nishima
2018-05-01
In the present study, we report a highly sensitive, rapid and low cost colorimetric monitoring of malathion (an organophosphate insecticide) employing a basic hexapeptide, malathion specific aptamer (oligonucleotide) and silver nanoparticles (AgNPs) as a nanoprobe. AgNPs are made to interact with the aptamer and peptide to give different optical responses depending upon the presence or absence of malathion. The nanoparticles remain yellow in color in the absence of malathion owing to the binding of aptamer with peptide which otherwise tends to aggregate the particles because of charge based interactions. In the presence of malathion, the agglomeration of the particles occurs which turns the solution orange. Furthermore, the developed aptasensor was successfully applied to detect malathion in various water samples and apple. The detection offered high recoveries in the range of 89-120% with the relative standard deviation within 2.98-4.78%. The proposed methodology exhibited excellent selectivity and a very low limit of detection i.e. 0.5 pM was achieved. The developed facile, rapid and low cost silver nanoprobe based on aptamer and peptide proved to be potentially applicable for highly selective and sensitive colorimetric sensing of trace levels of malathion in complex environmental samples. Figure S2. HPLC Chromatogram of KKKRRR. Figure S3. UV- Visible spectra of AgNPs in the presence of increasing peptide concentrations. Inset shows respective color changes of AgNPs with peptide concentrations ranging from 0.1 mM to 100 mM (a to e). Figure S4. UV- Visible spectra of AgNPs in the presence 10 mM peptide and varying aptamer concentrations. Inset shows the corresponding color changes. a to e shows aptamer concentrations ranging from 10 nM to 1000 nM. Figure S5. Interference Studies. Ratio of A520 nm/390 nm of AgNPs in the presence of 10 mM peptide, 500 nM aptamer, 0.5 nM malathion and 0.5 mM interfering components i.e. sodium, potassium, calcium, alanine, arginine, aspartic acid, ascorbic acid (AA) and glucose. Figure S6. (A) Absorbance spectra of AgNPs with increasing malathion concentrations. (B) Calibration plot for spiked lake water. Inset shows their respective images where a to g represents malathion concentrations from 0.01 nM to 0.75 nM. Each point represents an average of three individual measurements and error bars indicate standard deviation. Figure S7. (A) Absorbance spectra of AgNPs with increasing malathion concentrations in spiked tap water samples. (B) Calibration plot for the biosensor. Inset represents the color changes. a to g represents varying malathion concentrations from 0.01 nM to 0.75 nM. Each point represents an average of three individual measurements and error bars indicate standard deviation. Figure S8. (A) Absorbance spectra of AgNPs in the presence of different malathion concentrations in spiked apple samples. (B) Calibration plot for spiked apple. Inset displays the corresponding color changes. a to g shows the color of solutions having malathion concentrations from 0.01 nM to 0.75 nM. Each point represents an average of three individual measurements and error bars indicate standard deviation.
Wang, Guiqin; Wu, Yangsiqian; Lin, Yangting
2016-02-28
Nearly 99% of the total content of extraterrestrial metals is composed of Fe and Ni, but with greatly variable trace element contents. The accuracy obtained in the inductively coupled plasma mass spectrometry (ICP-MS) analysis of solutions of these samples can be significantly influenced by matrix contents, polyatomic ion interference, and the concentrations of external standard solutions. An ICP-MS instrument (X Series 2) was used to determine 30 standard solutions with different concentrations of trace elements, and different matrix contents. Based on these measurements, the matrix effects were determined. Three iron meteorites were dissolved separately in aqua regia and HNO3. Deviations due to variation of matrix contents in the external standard solutions were evaluated and the analysis results of the two digestion methods for iron meteorites were assessed. Our results show obvious deviations due to unmatched matrix contents in the external standard solutions. Furthermore, discrepancy in the measurement of some elements was found between the sample solutions prepared with aqua regia and HNO3, due to loss of chloride during sample preparation and/or incomplete digestion of highly siderophile elements in iron meteorites. An accurate ICP-MS analysis method for extraterrestrial metal samples has been established using external standard solutions with matched matrix contents and digesting the samples with HNO3 and aqua regia. Using the data from this work, the Mundrabilla iron meteorite previously classified as IAB-ung is reclassified as IAB-MG. Copyright © 2016 John Wiley & Sons, Ltd.
Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks
2016-04-01
Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard
1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...
Image contrast enhancement based on a local standard deviation model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Dah-Chung; Wu, Wen-Rong
1996-12-31
The adaptive contrast enhancement (ACE) algorithm is a widely used image enhancement method, which needs a contrast gain to adjust high frequency components of an image. In the literature, the gain is usually inversely proportional to the local standard deviation (LSD) or is a constant. But these cause two problems in practical applications, i.e., noise overenhancement and ringing artifact. In this paper a new gain is developed based on Hunt`s Gaussian image model to prevent the two defects. The new gain is a nonlinear function of LSD and has the desired characteristic emphasizing the LSD regions in which details aremore » concentrated. We have applied the new ACE algorithm to chest x-ray images and the simulations show the effectiveness of the proposed algorithm.« less
Riggio, Gustavo M; Chow, Judith C; Cropper, Paul M; Wang, Xiaoliang; Yatavelli, Reddy L N; Yang, Xufei; Watson, John G
2018-05-01
A thermal/optical carbon analyzer (TOA), normally used for quantification of organic carbon (OC) and elemental carbon (EC) in PM 2.5 (fine particulate matter) speciation networks, was adapted to direct thermally evolved gases to an electron impact quadrupole mass spectrometer (QMS), creating a TOA-QMS. This approach produces spectra similar to those obtained by the Aerodyne aerosol mass spectrometer (AMS), but the ratios of the mass to charge (m/z) signals differ and must be remeasured using laboratory-generated standards. Linear relationships are found between TOA-QMS signals and ammonium (NH 4 + ), nitrate (NO 3 - ), and sulfate (SO 4 2- ) standards. For ambient samples, however, positive deviations are found for SO 4 2- , compensated by negative deviations for NO 3 - , at higher concentrations. This indicates the utility of mixed-compound standards for calibration or separate calibration curves for low and high ion concentrations. The sum of the QMS signals across all m/z after removal of the NH 4 + , NO 3 - , and SO 4 2- signals was highly correlated with the carbon content of oxalic acid (C₂H₂O₄) standards. For ambient samples, the OC derived from the TOA-QMS method was the same as the OC derived from the standard IMPROVE_A TOA method. This method has the potential to reduce complexity and costs for speciation networks, especially for highly polluted urban areas such as those in Asia and Africa. Ammonium, nitrate, and sulfate can be quantified by the same thermal evolution analysis applied to organic and elemental carbon. This holds the potential to replace multiple parallel filter samples and separate laboratory analyses with a single filter and a single analysis to account for a large portion of the PM 2.5 mass concentration.
Davis, William E; Li, Yongtao
2008-07-15
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.
Hou, Siyuan; Riley, Christopher B; Mitchell, Cynthia A; Shaw, R Anthony; Bryanton, Janet; Bigsby, Kathryn; McClure, J Trenton
2015-09-01
Immunoglobulin G (IgG) is crucial for the protection of the host from invasive pathogens. Due to its importance for human health, tools that enable the monitoring of IgG levels are highly desired. Consequently there is a need for methods to determine the IgG concentration that are simple, rapid, and inexpensive. This work explored the potential of attenuated total reflectance (ATR) infrared spectroscopy as a method to determine IgG concentrations in human serum samples. Venous blood samples were collected from adults and children, and from the umbilical cord of newborns. The serum was harvested and tested using ATR infrared spectroscopy. Partial least squares (PLS) regression provided the basis to develop the new analytical methods. Three PLS calibrations were determined: one for the combined set of the venous and umbilical cord serum samples, the second for only the umbilical cord samples, and the third for only the venous samples. The number of PLS factors was chosen by critical evaluation of Monte Carlo-based cross validation results. The predictive performance for each PLS calibration was evaluated using the Pearson correlation coefficient, scatter plot and Bland-Altman plot, and percent deviations for independent prediction sets. The repeatability was evaluated by standard deviation and relative standard deviation. The results showed that ATR infrared spectroscopy is potentially a simple, quick, and inexpensive method to measure IgG concentrations in human serum samples. The results also showed that it is possible to build a united calibration curve for the umbilical cord and the venous samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Wu, Tzi-Yi; Chen, Bor-Kuan; Hao, Lin; Peng, Yu-Chun; Sun, I-Wen
2011-01-01
A systematic study of the effect of composition on the thermo-physical properties of the binary mixtures of 1-methyl-3-pentyl imidazolium hexafluorophosphate [MPI][PF6] with poly(ethylene glycol) (PEG) [Mw = 400] is presented. The excess molar volume, refractive index deviation, viscosity deviation, and surface tension deviation values were calculated from these experimental density, ρ, refractive index, n, viscosity, η, and surface tension, γ, over the whole concentration range, respectively. The excess molar volumes are negative and continue to become increasingly negative with increasing temperature; whereas the viscosity and surface tension deviation are negative and become less negative with increasing temperature. The surface thermodynamic functions, such as surface entropy, enthalpy, as well as standard molar entropy, Parachor, and molar enthalpy of vaporization for pure ionic liquid, have been derived from the temperature dependence of the surface tension values. PMID:21731460
Upgraded FAA Airfield Capacity Model. Volume 1. Supplemental User’s Guide
1981-02-01
SIGMAR (P4.0) cc 1-4 -standard deviation, in seconds, of arrival runway occupancy time (R.O.T.). SIGMAA (F4.0) cc 5-8 -standard deviation, in seconds...iI SI GMAC - The standard deviation of the time from departure clearance to start of roll. SIGMAR - The standard deviation of the arrival runway
Mars Global Reference Atmospheric Model (Mars-GRAM) and Database for Mission Design
NASA Technical Reports Server (NTRS)
Justus, C. G.; Duvall, Aleta; Johnson, D. L.
2003-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model, while above 80 km it is based on Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter. Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science and Thermal Emission Spectrometer data. RS data from 2480 profiles were used, covering latitudes 75 deg S to 72 deg N, surface to approximately 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160 deg and 265-310 deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, RS density varied by about a factor of 2.5 over ranges of latitudes and Ls values observed. Evaluated at matching positions and times, these figures show average RSMars-GRAM density ratios were generally 1+/-)0.05, except at heights above approximately 25 km and latitudes above approximately 50 deg N. Average standard deviation of RSMars-GRAM density ratio was 6%. TES data were used covering surface to approximately 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). Depending on season, TES data covered latitudes 85 deg S to 85 deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (greater than 45 deg N), or at most altitudes in the southern hemisphere at Ls approximately 90 and 180 deg. Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approximately 2.5% for all data, or approximately 1-4%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about three times the standard deviation of TES data about the TES mean value at a given position and season.
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
ESTIMATION OF RADIOACTIVE CALCIUM-45 BY LIQUID SCINTILLATION COUNTING
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lutwak, L.
1959-03-01
A liquid sclntillation counting method is developed for determining radioactive calcium-45 in biological materials. The calcium-45 is extracted, concentrated, and dissolved in absolute ethyl alcohol to which is added 0.4% diphenyloxazol in toluene. Counting efficiency is about 65 percent with standard deviation of the J-57 engin 7.36 percent. (auth)
Fiamegkos, I; Cordeiro, F; Robouch, P; Vélez, D; Devesa, V; Raber, G; Sloth, J J; Rasmussen, R R; Llorente-Mirandes, T; Lopez-Sanchez, J F; Rubio, R; Cubadda, F; D'Amato, M; Feldmann, J; Raab, A; Emteborg, H; de la Calle, M B
2016-12-15
A collaborative trial was conducted to determine the performance characteristics of an analytical method for the quantification of inorganic arsenic (iAs) in food. The method is based on (i) solubilisation of the protein matrix with concentrated hydrochloric acid to denature proteins and allow the release of all arsenic species into solution, and (ii) subsequent extraction of the inorganic arsenic present in the acid medium using chloroform followed by back-extraction to acidic medium. The final detection and quantification is done by flow injection hydride generation atomic absorption spectrometry (FI-HG-AAS). The seven test items used in this exercise were reference materials covering a broad range of matrices: mussels, cabbage, seaweed (hijiki), fish protein, rice, wheat, mushrooms, with concentrations ranging from 0.074 to 7.55mgkg(-1). The relative standard deviation for repeatability (RSDr) ranged from 4.1 to 10.3%, while the relative standard deviation for reproducibility (RSDR) ranged from 6.1 to 22.8%. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Wei, Xiangyang; Peng, Yanke; Jing, Gaoshan; Cui, Tianhong
2018-05-01
The thickness of perovskite absorber layer is a critical parameter to determine a planar structured perovskite solar cell’s performance. By modifying the spin coating speed and PbI2/N,N-dimethylformamide (DMF) solution concentration, the thickness of perovskite absorber layer was optimized to obtain high-performance solar cells. Using a PbI2/DMF solution of 1.3 mol/L, maximum power conversion efficiency (PCE) of a perovskite solar cell is 15.5% with a perovskite film of 413 nm at 5000 rpm, and PCE of 14.3% was also obtained for a solar cell with a perovskite film of 182 nm thick. It is derived that higher concentration of PbI2/DMF will result in better perovskite solar cells. Additionally, these perovskite solar cells are highly uniform. In 14 sets of solar cells, standard deviations of 11 sets of solar cells were less than 0.50% and the smallest standard deviation was 0.25%, which demonstrates the reliability and effectiveness of hybrid physical chemical vapor deposition (HPCVD) method.
Selvi, Emine Kılıçkaya; Şahin, Uğur; Şahan, Serkan
2017-01-01
This method was developed for the determination of trace amounts of aluminum(III) in dialysis concentrates using atomic absorption spectrometry after coprecipitation with lanthanum phosphate. The analytical parameters that influenced the quantitative coprecipitation of analyte including amount of lanthanum, amount of phosfate, pH and duration time were optimized. The % recoveries of the analyte ion were in the range of 95-105 % with limit of detection (3s) of 0.5 µg l -1 . Preconcentration factor was found as 1000 and Relative Standard Deviation (RSD) % value obtained from model solutions was 2.5% for 0.02 mg L -1 . The accuracy of the method was evaluated with standard reference material (CWW-TMD Waste Water). The method was also applied to most concentrated acidic and basic dialysis concentrates with satisfactory results.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
Keller, Jennifer M; Calafat, Antonia M; Kato, Kayoko; Ellefson, Mark E; Reagen, William K; Strynar, Mark; O'Connell, Steven; Butt, Craig M; Mabury, Scott A; Small, Jeff; Muir, Derek C G; Leigh, Stefan D; Schantz, Michele M
2010-05-01
Standard Reference Materials (SRMs) are certified reference materials produced by the National Institute of Standards and Technology that are homogeneous materials well characterized with values for specified properties, such as environmental contaminant concentrations. They can be used to validate measurement methods and are critical in improving data quality. Disagreements in perfluorinated alkyl acid (PFAA) concentrations measured in environmental matrices during past interlaboratory comparisons emphasized the need for SRMs with values assigned for PFAAs. We performed a new interlaboratory comparison among six laboratories and provided, for the first time, value assignment of PFAAs in SRMs. Concentrations for perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), and other PFAAs in two human serum and two human milk SRMs are reported. PFAA concentration measurements agreed for serum SRM 1957 using different analytical methods in six laboratories and for milk SRM 1954 in three laboratories. The interlaboratory relative standard deviation for PFOS in SRM 1957 was 7%, which is an improvement over past interlaboratory studies. Matrix interferences are discussed, as well as temporal trends and the percentage of branched vs. linear isomers. The concentrations in these SRMs are similar to the present-day average concentrations measured in human serum and milk, resulting in representative and useful control materials for PFAA human monitoring studies.
Depositional history of core section 74001 - Depth profiles of maturity, FeO, and metal
NASA Technical Reports Server (NTRS)
Morris, R. V.; Gose, W. A.
1977-01-01
Samples from every 0.5-cm interval of soil in core section 74001 have been studied by ferromagnetic resonance (FMR) and magnetic techniques. The values of the FMR maturity index show that the 74001 samples are very immature (the index ranges from 0.14 to 0.29 units) and have not seen appreciable, if any, surface exposure since their deposition. In fact, the small amount of fine-grained metal in the 74001 samples is probably not acquired as a result of their exposure to the micrometeoroid flux at the lunar surface. Thus, the black-glass soil of 74001 was deposited very rapidly, probably in a single episode or several closely spaced episodes of lunar fire fountaining. The average concentration of FeO and its standard deviation for all the 74001 samples are 22.5 + or - 0.3 wt.%. Since the FeO concentration is so uniform, no large variations in the major-element chemistry of 74001 are expected, with the possible exception of the volatile elements. The concentration of coarse-grained metal, which is measured magnetically, and its standard deviation are 0.15 + or - 0.01 wt.%. The coarse-grained metal probably precipitated contemporaneously with the silicate and oxide phases in the black-glass droplets.
Daily magnesium intake and serum magnesium concentration among Japanese people.
Akizawa, Yoriko; Koizumi, Sadayuki; Itokawa, Yoshinori; Ojima, Toshiyuki; Nakamura, Yosikazu; Tamura, Tarou; Kusaka, Yukinori
2008-01-01
The vitamins and minerals that are deficient in the daily diet of a normal adult remain unknown. To answer this question, we conducted a population survey focusing on the relationship between dietary magnesium intake and serum magnesium level. The subjects were 62 individuals from Fukui Prefecture who participated in the 1998 National Nutrition Survey. The survey investigated the physical status, nutritional status, and dietary data of the subjects. Holidays and special occasions were avoided, and a day when people are most likely to be on an ordinary diet was selected as the survey date. The mean (+/-standard deviation) daily magnesium intake was 322 (+/-132), 323 (+/-163), and 322 (+/-147) mg/day for men, women, and the entire group, respectively. The mean (+/-standard deviation) serum magnesium concentration was 20.69 (+/-2.83), 20.69 (+/-2.88), and 20.69 (+/-2.83) ppm for men, women, and the entire group, respectively. The distribution of serum magnesium concentration was normal. Dietary magnesium intake showed a log-normal distribution, which was then transformed by logarithmic conversion for examining the regression coefficients. The slope of the regression line between the serum magnesium concentration (Y ppm) and daily magnesium intake (X mg) was determined using the formula Y = 4.93 (log(10)X) + 8.49. The coefficient of correlation (r) was 0.29. A regression line (Y = 14.65X + 19.31) was observed between the daily intake of magnesium (Y mg) and serum magnesium concentration (X ppm). The coefficient of correlation was 0.28. The daily magnesium intake correlated with serum magnesium concentration, and a linear regression model between them was proposed.
Lee, Jungmin; Durst, Robert W; Wrolstad, Ronald E
2005-01-01
This collaborative study was conducted to determine the total monomeric anthocyanin concentration by the pH differential method, which is a rapid and simple spectrophotometric method based on the anthocyanin structural transformation that occurs with a change in pH (colored at pH 1.0 and colorless at pH 4.5). Eleven collaborators representing commercial laboratories, academic institutions, and government laboratories participated. Seven Youden pair materials representing fruit juices, beverages, natural colorants, and wines were tested. The repeatability relative standard deviation (RSDr) varied from 1.06 to 4.16%. The reproducibility relative standard deviation (RSDR) ranged from 2.69 to 10.12%. The HorRat values were < or = 1.33 for all materials. The Study Director recommends that the method be adopted Official First Action.
Beljaars, P R; Van Dijk, R; Jonker, K M; Schout, L J
1998-01-01
An interlaboratory study of the liquid chromatographic (LC) determination of histamine in fish, sauerkraut, and wine was conducted. Diminuted and homogenized samples were suspended in water followed by clarification of extracts with perchloric acid, filtration, and dilution with water. After LC separation on a reversed-phase C18 column with phosphate buffer (pH 3.0)--acetonitrile (875 + 125, v/v) as mobile phase, histamine was measured fluorometrically (excitation, 340 nm; emission, 455 nm) in samples and standards after postcolumn derivatization with o-phthaldialdehyde (OPA). Fourteen samples (including 6 blind duplicates and 1 split level) containing histamine at about 10-400 mg/kg or mg/L were analyzed singly according to the proposed procedure by 11 laboratories. Results from one participant were excluded from statistical analysis. For all samples analyzed, repeatability relative standard deviations varied from 2.1 to 5.6%, and reproducibility relative standard deviations ranged from 2.2 to 7.1%. Averaged recoveries of histamine for this concentration range varied from 94 to 100%.
Study of Sinhalizations in Sinhala-English Mixed Discourse
ERIC Educational Resources Information Center
Senaratne, Chamindi Dilkushi
2014-01-01
Pronunciation plays a vital role in creating a language acceptable to all. This is also true in the case of Sri Lankan English (hereafter SLE). This study concentrates mainly on the phonological features of non-standard SLE, identified mainly by deviations in pronunciation of a few vowels and consonants. The objective of this paper is to analyze…
CONCENTRATIONS AND SOLUBILITY OF METALS FROM INDOOR AND PERSONAL EXPOSURE PM2.5 SAMPLES
An assessment of trace metal quantification capabilities for indoor (123 ± 53 μg; mean ± standard deviation of particle mass) and personal exposure (32 ± 12 μg) PM2.5 samples from Baltimore, MD was undertaken as part of an EPA study investigating health effects assoc...
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Nagel, Christina; Trenk, Lisa; Aurich, Christine; Ille, Natascha; Pichler, Martina; Drillich, Marc; Pohl, Werner; Aurich, Jörg
2016-03-15
Increased cortisol release in parturient cows may either represent a stress response or is part of the endocrine changes that initiate calving. Acute stress elicits an increase in heart rate and decrease in heart rate variability (HRV). Therefore, we analyzed cortisol concentration, heart rate and HRV variables standard deviation of beat-to-beat interval (SDRR) and root mean square of successive beat-to-beat intervals (RMSSD) in dairy cows allowed to calve spontaneously (SPON, n = 6) or with PGF2α-induced preterm parturition (PG, n = 6). We hypothesized that calving is a stressor, but induced parturition is less stressful than term calving. Saliva collection for cortisol analysis and electrocardiogram recordings for heart rate and HRV analysis were performed from 32 hours before to 18.3 ± 0.7 hours after delivery. Cortisol concentration increased in SPON and PG cows, peaked 15 minutes after delivery (P < 0.001) but was higher in SPON versus PG cows (P < 0.001) during and within 2 hours after calving. Heart rate peaked during the expulsive phase of labor and was higher in SPON than in PG cows (time × group P < 0.01). The standard deviation of beat-to-beat interval and RMSSD peaked at the end of the expulsive phase of labor (P < 0.001), indicating high vagal activity. Standard deviation of beat-to-beat interval (P < 0.01) and RMSSD (P < 0.05) were higher in SPON versus PG cows. Based on physiological stress parameters, calving is perceived as stressful but expulsion of the calf is associated with a transiently increased vagal tone which may enhance uterine contractility. Copyright © 2016 Elsevier Inc. All rights reserved.
Hager, Stephen W.
1994-01-01
Particulate matter was collected at Rio Vista, California, in two study periods; the first, from January 3 to May 26, 1983; the second from October 31, 1983 to November 29, 1984. Concentrations of suspended particulate matter were measured gravimetrically on silver membrane filters. The pooled standard deviation on replicated samples was 1.4 mg/L, giving a coefficient of variation of 5.7 percent. Concentrations of particulate carbon and nitrogen were measured during a Perkin-Elmer model 240C elemental analyzer to combust material collected on glass fiber filters. Refrigeration of samples prior to filtration was shown to be a likely influence on precision of duplicate analyses. Median deviations between duplicates for carbon were 5.4 percent during the first study period and 8.9 percent during the second. For nitrogen, median deviations were 4.9 percent and 7.2 percent, respectively. This report presents the data for concentrations of suspended particulate material, the duplicate analyses for particulate carbon and nitrogen, and the volumes of sample filtered for the particulate carbon and nitrogen analyses for both studies. Not all samples collected during the second study have been analyzed for particulate carbon and nitrogen.
Jin, Hye Young
2018-05-16
Subclinical hypothyroidism is defined as elevated thyroid-stimulating hormone (TSH) levels with the normal concentrations of thyroxine (T4) or free thyroxine (fT4), and its clinical significance is unclear. The purpose of this study is to investigate the prevalence of subclinical hypothyroidism in children and adolescents and determine the relationship between lipid profiles, insulin resistance and thyroid hormones. A retrospective, cross-sectional study was performed using data from a subset of the KNHANES VI. The subjects whose ages were in the range of 10-19 years were enrolled when their thyroid function tests were available (n = 1104), and their laboratory and anthropometric data were analysed. Subclinical hypothyroidism was more commonly identified in the obese group (27 of 111) compared to the other groups (127 of 993) (24.3 vs. 12.8%, P = 0.002). Total cholesterol and triglyceride levels were higher in a group with subclinical hypothyroidism. Body mass index (BMI) was positively correlated with serum concentrations of the TSH and negatively correlated with serum concentrations of fT4 after adjusting for age. The concentrations of total cholesterol and triglyceride were positively correlated with the TSH concentrations following adjustment for age and BMI standard deviation scores. The fT4 concentrations were negatively linked with total cholesterol after adjusting for age and BMI standard deviation scores. No significant correlation was found between insulin resistance index and TSH and fT4. Subclinical hypothyroidism was common in the obese group, and the concentrations of TSH were linked with the lipid profile. Subclinical hypothyroidism in obese children or adolescents should be closely monitored while also evaluating metabolic risk factors. © 2018 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).
Dynamically formed admicelle layer to control the amplitude of cathodic electroosmotic flow.
Erny, Guillaume L; Gonçalves, Bruna M; Esteves, Valdemar I
2012-09-21
In this manuscript, a method to precisely adjust the amplitude of a cathodic electroosmotic flow is described. The method uses a capillary pre-coated with a cationic polymer (polybrene), in presence of an anionic surfactant such as sodium dodecyl sulfate. At low concentration of surfactant, molecules will self-assemble to form an immobilized hemimicelle layer with the anionic "head" in contact with the cationic coating and the hydrophobic tail reaching into the background electrolyte. At higher concentration, surfactant molecules in solution will then interact, via hydrophobic interactions, to form an admicelle layer. It has been demonstrated that the admicelle layer can be constructed with either pure anionic surfactant (SDS), or a mixture of anionic and neutral surfactants. Admicelle coatings can be used to control the electroosmotic flow (EOF). While at low surfactant concentration the amplitude of the EOF depends on the concentration of the surfactants concentration, when this concentration reaches the critical admicelle concentration the EOF becomes near constant. The amplitude of the EOF can also be adjusted via the relative proportion of neutral and ionic surfactant in solution. Using this approach, the EOF was varied from 0.450 to 3.848 × 10(-8)m(2)V(-1)s(-1) with a precision below 0.050 × 10(-8)m(2)V(-1)s(-1) (standard deviation measured with three replicates). The coating has been tested using a mix of triazines (atrazine, simazine and terbuthylazine) and a beer sample. With the beer sample an average relative standard deviation of 1.5% for the migration time and of 2.2% for the corrected peak area was obtained. Copyright © 2012 Elsevier B.V. All rights reserved.
Gibson, Richard; Becerril-Bravo, Elías; Silva-Castro, Vanessa; Jiménez, Blanca
2007-10-26
Although the trend in development of analytical methods for emerging contaminants is towards reduced sample preparation and increased detector selectivity, there are still benefits from removal of matrix material during sample preparation. This paper describes a simple method for acidic pharmaceuticals and a range of potential endocrine disrupting compounds in untreated wastewaters and spring waters. It is based on separation of the two classes during elution from the extraction cartridge with final analysis by gas chromatography-mass spectrometry. 3,4-D was used as the recovery standard for the acids while 4-n-nonylphenol and [2H4]estrone were used for the endocrine disrupters; mean recoveries varied between 89% and 111%. The method was also extensively validated by fortification with the target compounds. Recoveries of acids were from 68% to 97% with relative standard deviations generally less than 10% and recoveries of endocrine disrupters were 68-109% with relative standard deviations less than 20%. Detection limits varied from 0.005 to 1 ng/L in spring water, and from 0.5 to 100 ng/L in untreated wastewater. Concentrations of the analytes in the wastewater ranged from 0.018 to 22.4 microg/L. Values were comparable to reported data, although concentrations were generally relatively high, probably because of a lack of treatment. Triclosan, phthalates, estrone, 17beta-estradiol, ibuprofen, and naproxen were present in the spring water from aquifers recharged indirectly with this wastewater after its use for irrigation; concentrations ranged from 0.01 to 25.0 ng/L. The much lower concentrations compared to wastewater indicate effective removal processes on passage through the soil and subsoil.
Indirect spectrophotometric determination of traces of bromide in water
Fishman, M. J.; Skougstad, M.W.
1963-01-01
A rapid, accurate, and sensitive indirect spectrophotometric method for the determination of bromide in natural waters is based on the catalytic effect of bromide on the oxidation of iodine to iodate by potassium permanganate in sulfuric acid solution. The method is applicable to concentrations ranging from 1 to 100 ??g. of bromide per liter, but may be modified to extend the concentration range. Most ions commonly occurring in water do not interfere. The standard deviation is 2.9 at bromide concentrations of 100 ??g. per liter and less at lower concentrations. The determination of bromide in samples containing known added amounts gave values ranging from 99 to 105% of the concentration calculated to be present.
Conductivity detection for monitoring mixing reactions in microfluidic devices.
Liu, Y; Wipf, D O; Henry, C S
2001-08-01
A conductivity detector was coupled to poly(dimethylsiloxane)-glass capillary electrophoresis microchips to monitor microfluidic flow. Electroosmotic flow was investigated with both conductivity detection (CD) and the current monitoring method. No significant variation was observed between these methods, but CD showed a lower relative standard deviation. Gradient mixing experiments were employed to investigate the relationship between the electrolyte conductivity and the electrolyte concentration. A good linear response of conductivity to concentration was obtained for solutions whose difference in concentrations were less than 27 mM. The new system holds great promise for precision mixing in microfluidic devices using electrically driven flows.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
Tuerk, Andreas; Wiktorin, Gregor; Güler, Serhat
2017-05-01
Accuracy of transcript quantification with RNA-Seq is negatively affected by positional fragment bias. This article introduces Mix2 (rd. "mixquare"), a transcript quantification method which uses a mixture of probability distributions to model and thereby neutralize the effects of positional fragment bias. The parameters of Mix2 are trained by Expectation Maximization resulting in simultaneous transcript abundance and bias estimates. We compare Mix2 to Cufflinks, RSEM, eXpress and PennSeq; state-of-the-art quantification methods implementing some form of bias correction. On four synthetic biases we show that the accuracy of Mix2 overall exceeds the accuracy of the other methods and that its bias estimates converge to the correct solution. We further evaluate Mix2 on real RNA-Seq data from the Microarray and Sequencing Quality Control (MAQC, SEQC) Consortia. On MAQC data, Mix2 achieves improved correlation to qPCR measurements with a relative increase in R2 between 4% and 50%. Mix2 also yields repeatable concentration estimates across technical replicates with a relative increase in R2 between 8% and 47% and reduced standard deviation across the full concentration range. We further observe more accurate detection of differential expression with a relative increase in true positives between 74% and 378% for 5% false positives. In addition, Mix2 reveals 5 dominant biases in MAQC data deviating from the common assumption of a uniform fragment distribution. On SEQC data, Mix2 yields higher consistency between measured and predicted concentration ratios. A relative error of 20% or less is obtained for 51% of transcripts by Mix2, 40% of transcripts by Cufflinks and RSEM and 30% by eXpress. Titration order consistency is correct for 47% of transcripts for Mix2, 41% for Cufflinks and RSEM and 34% for eXpress. We, further, observe improved repeatability across laboratory sites with a relative increase in R2 between 8% and 44% and reduced standard deviation.
Ozone trends and their relationship to characteristic weather patterns.
Austin, Elena; Zanobetti, Antonella; Coull, Brent; Schwartz, Joel; Gold, Diane R; Koutrakis, Petros
2015-01-01
Local trends in ozone concentration may differ by meteorological conditions. Furthermore, the trends occurring at the extremes of the Ozone distribution are often not reported even though these may be very different than the trend observed at the mean or median and they may be more relevant to health outcomes. Classify days of observation over a 16-year period into broad categories that capture salient daily local weather characteristics. Determine the rate of change in mean and median O3 concentrations within these different categories to assess how concentration trends are impacted by daily weather. Further examine if trends vary for observations in the extremes of the O3 distribution. We used k-means clustering to categorize days of observation based on the maximum daily temperature, standard deviation of daily temperature, mean daily ground level wind speed, mean daily water vapor pressure and mean daily sea-level barometric pressure. The five cluster solution was determined to be the appropriate one based on cluster diagnostics and cluster interpretability. Trends in cluster frequency and pollution trends within clusters were modeled using Poisson regression with penalized splines as well as quantile regression. There were five characteristic groupings identified. The frequency of days with large standard deviations in hourly temperature decreased over the observation period, whereas the frequency of warmer days with smaller deviations in temperature increased. O3 trends were significantly different within the different weather groupings. Furthermore, the rate of O3 change for the 95th percentile and 5th percentile was significantly different than the rate of change of the median for several of the weather categories.We found that O3 trends vary between different characteristic local weather patterns. O3 trends were significantly different between the different weather groupings suggesting an important interaction between changes in prevailing weather conditions and O3 concentration.
Wang, Jiancheng; Xie, Zhouqing; Wang, Feiyue; Kang, Hui
2017-12-15
Gaseous elemental mercury (GEM) in the marine boundary layer (MBL), and dissolved gaseous mercury (DGM) in surface seawater of the Southern Ocean were measured in the austral summer from December 13, 2014 to February 1, 2015. GEM concentrations in the MBL ranged from 0.4 to 1.9ngm -3 (mean±standard deviation: 0.9±0.2ngm -3 ), whereas DGM concentrations in surface seawater ranged from 7.0 to 75.9pgL -1 (mean±standard deviation: 23.7±13.2pgL -1 ). The occasionally observed low GEM in the MBL suggested either the occurrence of atmospheric mercury depletion in summer, or the transport of GEM-depleted air from the Antarctic Plateau. Elevated GEM concentrations in the MBL and DGM concentrations in surface seawater were consistently observed in the ice-covered region of the Ross Sea implying the influence of the sea ice environment. Diminishing sea ice could cause more mercury evasion from the ocean to the air. Using the thin film gas exchange model, the air-sea fluxes of gaseous mercury in non-ice-covered area during the study period were estimated to range from 0.0 to 6.5ngm -2 h -1 with a mean value of 1.5±1.8ngm -2 h -1 , revealing GEM (re-)emission from the East Southern Ocean in summer. Copyright © 2017 Elsevier B.V. All rights reserved.
Josypčuk, Bohdan; Barek, Jiří; Josypčuk, Oksana
2013-05-17
A flow amperometric enzymatic biosensor for the determination of glucose was constructed. The biosensor consists of a flow reactor based on porous silver solid amalgam (AgSA) and a flow tubular detector based on compact AgSA. The preparation of the sensor and the determination of glucose occurred in three steps. First, a self-assembled monolayer of 11-mercaptoundecanoic acid (MUA) was formed at the porous surface of the reactor. Second, enzyme glucose oxidase (GOx) was covalently immobilized at MUA-layer using N-ethyl-N'-(3-dimethylaminopropyl) carboimide and N-hydroxysuccinimide chemistry. Finally, a decrease of oxygen concentration (directly proportional to the concentration of glucose) during enzymatic reaction was amperometrically measured on the tubular detector under flow injection conditions. The following parameters of glucose determination were optimized with respect to amperometric response: composition of the mobile phase, its concentration, the potential of detection and the flow rate. The calibration curve of glucose was linear in the concentration range of 0.02-0.80 mmol L(-1) with detection limit of 0.01 mmol L(-1). The content of glucose in the sample of honey was determined as 35.5±1.0 mass % (number of the repeated measurements n=7; standard deviation SD=1.2%; relative standard deviation RSD=3.2%) which corresponds well with the declared values. The tested biosensor proved good long-term stability (77% of the current response of glucose was retained after 35 days). Copyright © 2013 Elsevier B.V. All rights reserved.
Mars-Gram Validation with Mars Global Surveyor Data
NASA Technical Reports Server (NTRS)
Justus, C. G.; Johnson, D.; Parker, Nelson C. (Technical Monitor)
2002-01-01
Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many b4ars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topography from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with Mars Global Surveyor Radio Science (RS) and Thermal Emission Spectrometer (TES) data. RS data from 2480 profiles were used, covering latitudes 75deg S to 72deg N, surface to approx. 40 km, for seasons ranging from areocentric longitude of Sun (Ls) = 70-160deg and 265-310deg. RS data spanned a range of local times, mostly 0-9 hours and 18-24 hours. For interests in aerocapture and precision landing, comparisons concentrated on atmospheric density. At a fixed height of 20 km, measured RS density varied by about a factor of 2.5 over the range of latitudes and Ls values observed. Evaluated at matching positions and times, average RS/Mars-GRAM density ratios were generally lf0.05, except at heights above approx. 25 km and latitudes above approx.50deg N. Average standard deviation of RS/Mars-GRAM density ratio was 6%. TES data were used covering surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of Mars global dust storm). Depending on season, TES data covered latitudes 85deg S to 85deg N. Most TES data were concentrated near local times 2 hours and 14 hours. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 6.5-10.5% (varying with height) for all data, or approx. 5- 12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for 1o:al time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bamberger, Judith A.; Piepel, Gregory F.; Enderlin, Carl W.
Understanding how uncertainty manifests itself in complex experiments is important for developing the testing protocol and interpreting the experimental results. This paper describes experimental and measurement uncertainties, and how they can depend on the order of performing experimental tests. Experiments with pulse-jet mixers in tanks at three scales were conducted to characterize the performance of transient-developing periodic flows in Newtonian slurries. Other test parameters included the simulant, solids concentration, and nozzle exit velocity. Critical suspension velocity and cloud height were the metrics used to characterize Newtonian slurry flow associated with mobilization and mixing. During testing, near-replicate and near-repeat tests weremore » conducted. The experimental results were used to quantify the combined experimental and measurement uncertainties using standard deviations and percent relative standard deviations (%RSD) The uncertainties in critical suspension velocity and cloud height tend to increase with the values of these responses. Hence, the %RSD values are the more appropriate summary measure of near-replicate testing and measurement uncertainty.« less
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-11-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-09-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
USDA-ARS?s Scientific Manuscript database
For any analytical system the population mean (mu) number of entities (e.g., cells or molecules) per tested volume, surface area, or mass also defines the population standard deviation (sigma = square root of mu ). For a preponderance of analytical methods, sigma is very small relative to mu due to...
Navy Field Evaluation of Particle Counter Technology for Aviation Fuel Contamination Detection
2014-02-06
Naval Ship’s Technical Manual NAVAIR ... ………………………………………………………Naval Air Systems Command RSD ...6. Relative Standard Deviation of >4 µm Particle Count The high RSD between particle counts of the same sediment and free water concentrations are
Tendency for interlaboratory precision in the GMO analysis method based on real-time PCR.
Kodama, Takashi; Kurosawa, Yasunori; Kitta, Kazumi; Naito, Shigehiro
2010-01-01
The Horwitz curve estimates interlaboratory precision as a function only of concentration, and is frequently used as a method performance criterion in food analysis with chemical methods. The quantitative biochemical methods based on real-time PCR require an analogous criterion to progressively promote method validation. We analyzed the tendency of precision using a simplex real-time PCR technique in 53 collaborative studies of seven genetically modified (GM) crops. Reproducibility standard deviation (SR) and repeatability standard deviation (Sr) of the genetically modified organism (GMO) amount (%) was more or less independent of GM crops (i.e., maize, soybean, cotton, oilseed rape, potato, sugar beet, and rice) and evaluation procedure steps. Some studies evaluated whole steps consisting of DNA extraction and PCR quantitation, whereas others focused only on the PCR quantitation step by using DNA extraction solutions. Therefore, SR and Sr for GMO amount (%) are functions only of concentration similar to the Horwitz curve. We proposed S(R) = 0.1971C 0.8685 and S(r) = 0.1478C 0.8424, where C is the GMO amount (%). We also proposed a method performance index in GMO quantitative methods that is analogous to the Horwitz Ratio.
Inflammation is more distinct in temporomandibular joint osteoarthritis compared to the knee joint.
Vos, Lukas M; Kuijer, Roel; Huddleston Slater, James J R; Bulstra, Sjoerd K; Stegenga, Boudewijn
2014-01-01
Most of the current understanding of articular cartilage maintenance and degradation is derived from large load-bearing synovial joints, in particular the knee joint. The aim of this study was to identify valuable degradation markers for cartilage degradation in the temporomandibular joint (TMJ) by comparing the relative concentrations of carboxyterminal telopeptides of collagen types I and II (CTX-I and CTX-II), cartilage oligomeric matrix protein (COMP), and prostaglandin E2 (PGE2) in synovial fluid (SF) of TMJ and knee joints with cartilage degradation. In this cross-sectional comparative study, participants were recruited from the University Medical Center Groningen, The Netherlands. Patients with TMJ osteoarthritis were compared with patients with knee osteoarthritis. The outcome variables were the relative SF concentrations of CTX-I, CTX-II, COMP, and PGE2. An independent samples Mann-Whitney U test was used to compare the relative concentrations. Thirty consecutive patients (9 male, 21 female; mean age, 40.1 yr; standard deviation, 15.3 yr) with TMJ osteoarthritis and 31 consecutive patients (20 male, 11 female; mean age, 37.4 yr; standard deviation, 13.7 yr) who were scheduled for arthroscopy of the knee joint participated in this study. Significant differences were found between relative concentrations of COMP (P = .000) and PGE2 (P = .005), and no significant differences were found between relative concentrations of CTX-I (P = .720) and CTX-II (P = .242). Relative SF concentrations of COMP and PGE2 showed significant differences between the TMJ and the knee joint, suggesting that there are differences in pathophysiology and that the inflammatory component may be more distinct in the TMJ. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Daily Magnesium Intake and Serum Magnesium Concentration among Japanese People
Akizawa, Yoriko; Koizumi, Sadayuki; Itokawa, Yoshinori; Ojima, Toshiyuki; Nakamura, Yosikazu; Tamura, Tarou; Kusaka, Yukinori
2008-01-01
Background The vitamins and minerals that are deficient in the daily diet of a normal adult remain unknown. To answer this question, we conducted a population survey focusing on the relationship between dietary magnesium intake and serum magnesium level. Methods The subjects were 62 individuals from Fukui Prefecture who participated in the 1998 National Nutrition Survey. The survey investigated the physical status, nutritional status, and dietary data of the subjects. Holidays and special occasions were avoided, and a day when people are most likely to be on an ordinary diet was selected as the survey date. Results The mean (±standard deviation) daily magnesium intake was 322 (±132), 323 (±163), and 322 (±147) mg/day for men, women, and the entire group, respectively. The mean (±standard deviation) serum magnesium concentration was 20.69 (±2.83), 20.69 (±2.88), and 20.69 (±2.83) ppm for men, women, and the entire group, respectively. The distribution of serum magnesium concentration was normal. Dietary magnesium intake showed a log-normal distribution, which was then transformed by logarithmic conversion for examining the regression coefficients. The slope of the regression line between the serum magnesium concentration (Y ppm) and daily magnesium intake (X mg) was determined using the formula Y = 4.93 (log10X) + 8.49. The coefficient of correlation (r) was 0.29. A regression line (Y = 14.65X + 19.31) was observed between the daily intake of magnesium (Y mg) and serum magnesium concentration (X ppm). The coefficient of correlation was 0.28. Conclusion The daily magnesium intake correlated with serum magnesium concentration, and a linear regression model between them was proposed. PMID:18635902
NASA Astrophysics Data System (ADS)
Lim, Jeong Sik; Park, Miyeon; Lee, Jinbok; Lee, Jeongsoon
2017-12-01
The effect of background gas composition on the measurement of CO2 levels was investigated by wavelength-scanned cavity ring-down spectrometry (WS-CRDS) employing a spectral line centered at the R(1) of the (3 00 1)III ← (0 0 0) band. For this purpose, eight cylinders with various gas compositions were gravimetrically and volumetrically prepared within 2σ = 0.1 %, and these gas mixtures were introduced into the WS-CRDS analyzer calibrated against standards of ambient air composition. Depending on the gas composition, deviations between CRDS-determined and gravimetrically (or volumetrically) assigned CO2 concentrations ranged from -9.77 to 5.36 µmol mol-1, e.g., excess N2 exhibited a negative deviation, whereas excess Ar showed a positive one. The total pressure broadening coefficients (TPBCs) obtained from the composition of N2, O2, and Ar thoroughly corrected the deviations up to -0.5 to 0.6 µmol mol-1, while these values were -0.43 to 1.43 µmol mol-1 considering PBCs induced by only N2. The use of TPBC enhanced deviations to be corrected to ˜ 0.15 %. Furthermore, the above correction linearly shifted CRDS responses for a large extent of TPBCs ranging from 0.065 to 0.081 cm-1 atm-1. Thus, accurate measurements using optical intensity-based techniques such as WS-CRDS require TPBC-based instrument calibration or use standards prepared in the same background composition of ambient air.
NASA Astrophysics Data System (ADS)
Profe, Jörn; Ohlendorf, Christian
2017-04-01
XRF-scanning is the state-of-the-art technique for geochemical analyses in marine and lacustrine sedimentology for more than a decade. However, little attention has been paid to data precision and technical limitations so far. Using homogenized, dried and powdered samples (certified geochemical reference standards and samples from a lithologically-contrasting loess-paleosol sequence) minimizes many adverse effects that influence the XRF-signal when analyzing wet sediment cores. This allows the investigation of data precision under ideal conditions and documents a new application of the XRF core-scanner technology at the same time. Reliable interpretations of XRF results require data precision evaluation of single elements as a function of X-ray tube, measurement time, sample compaction and quality of peak fitting. Ten-fold measurement of each sample constitutes data precision. Data precision of XRF measurements theoretically obeys Poisson statistics. Fe and Ca exhibit largest deviations from Poisson statistics. The same elements show the least mean relative standard deviations in the range from 0.5% to 1%. This represents the technical limit of data precision achievable by the installed detector. Measurement times ≥ 30 s reveal mean relative standard deviations below 4% for most elements. The quality of peak fitting is only relevant for elements with overlapping fluorescence lines such as Ba, Ti and Mn or for elements with low concentrations such as Y, for example. Differences in sample compaction are marginal and do not change mean relative standard deviation considerably. Data precision is in the range reported for geochemical reference standards measured by conventional techniques. Therefore, XRF scanning of discrete samples provide a cost- and time-efficient alternative to conventional multi-element analyses. As best trade-off between economical operation and data quality, we recommend a measurement time of 30 s resulting in a total scan time of 30 minutes for 30 samples.
Validation of an integrative mathematical model of dehydration and rehydration in virtual humans.
Pruett, W Andrew; Clemmer, John S; Hester, Robert L
2016-11-01
Water homeostasis is one of the body's most critical tasks. Physical challenges to the body, including exercise and surgery, almost always coordinate with some change in water handling reflecting the changing needs of the body. Vasopressin is the most important hormone that contributes to short-term water homeostasis. By manipulating vascular tone and regulating water reabsorption in the collecting duct of the kidneys, vasopressin can mediate the retention or loss of fluids quickly. In this study, we validated HumMod, an integrative mathematical model of human physiology, against six different challenges to water homeostasis with special attention to the secretion of vasopressin and maintenance of electrolyte balance. The studies chosen were performed in normal men and women, and represent a broad spectrum of perturbations. HumMod successfully replicated the experimental results, remaining within 1 standard deviation of the experimental means in 138 of 161 measurements. Only three measurements lay outside of the second standard deviation. Observations were made on serum osmolarity, serum vasopressin concentration, serum sodium concentration, urine osmolarity, serum protein concentration, hematocrit, and cumulative water intake following dehydration. This validation suggests that HumMod can be used to understand water homeostasis under a variety of conditions. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
NASA Astrophysics Data System (ADS)
Moreno de Castro, Maria; Schartau, Markus; Wirtz, Kai
2017-04-01
Mesocosm experiments on phytoplankton dynamics under high CO2 concentrations mimic the response of marine primary producers to future ocean acidification. However, potential acidification effects can be hindered by the high standard deviation typically found in the replicates of the same CO2 treatment level. In experiments with multiple unresolved factors and a sub-optimal number of replicates, post-processing statistical inference tools might fail to detect an effect that is present. We propose that in such cases, data-based model analyses might be suitable tools to unearth potential responses to the treatment and identify the uncertainties that could produce the observed variability. As test cases, we used data from two independent mesocosm experiments. Both experiments showed high standard deviations and, according to statistical inference tools, biomass appeared insensitive to changing CO2 conditions. Conversely, our simulations showed earlier and more intense phytoplankton blooms in modeled replicates at high CO2 concentrations and suggested that uncertainties in average cell size, phytoplankton biomass losses, and initial nutrient concentration potentially outweigh acidification effects by triggering strong variability during the bloom phase. We also estimated the thresholds below which uncertainties do not escalate to high variability. This information might help in designing future mesocosm experiments and interpreting controversial results on the effect of acidification or other pressures on ecosystem functions.
Gao, Chen-chen; Li, Feng-min; Lu, Lun; Sun, Yue
2015-10-01
For the determination of trace amounts of phthalic acid esters (PAEs) in complex seawater matrix, a stir bar sorptive extraction gas chromatography mass spectrometry (SBSE-GC-MS) method was established. Dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), butyl benzyl phthalate (BBP), dibutyl phthalate (2-ethylhexyl) phthalate (DEHP) and dioctyl phthalate (DOP) were selected as study objects. The effects of extraction time, amount of methanol, amount of sodium chloride, desorption time and desorption solvent were optimized. The method of SBSE-GC-MS was validated through recoveries and relative standard deviation. The optimal extraction time was 2 h. The optimal methanol content was 10%. The optimal sodium chloride content was 5% . The optimal desorption time was 50 min. The optimal desorption solvent was the mixture of methanol to acetonitrile (4:1, volume: volume). The linear relationship between the peak area and the concentration of PAEs was relevant. The correlation coefficients were greater than 0.997. The detection limits were between 0.25 and 174.42 ng x L(-1). The recoveries of different concentrations were between 56.97% and 124.22% . The relative standard deviations were between 0.41% and 14.39%. On the basis of the method, several estuaries water sample of Jiaozhou Bay were detected. DEP was detected in all samples, and the concentration of BBP, DEHP and DOP were much higher than the rest.
Portable device for the detection of colorimetric assays
Nowak, E.; Kawchuk, J.; Hoorfar, M.; Najjaran, H.
2017-01-01
In this work, a low-cost, portable device is developed to detect colorimetric assays for in-field and point-of-care (POC) analysis. The device can rapidly detect both pH values and nitrite concentrations of five different samples, simultaneously. After mixing samples with specific reagents, a high-resolution digital camera collects a picture of the sample, and a single-board computer processes the image in real time to identify the hue–saturation–value coordinates of the image. An internal light source reduces the effect of any ambient light so the device can accurately determine the corresponding pH values or nitrite concentrations. The device was purposefully designed to be low-cost, yet versatile, and the accuracy of the results have been compared to those from a conventional method. The results obtained for pH values have a mean standard deviation of 0.03 and a correlation coefficient R2 of 0.998. The detection of nitrites is between concentrations of 0.4–1.6 mg l−1, with a low detection limit of 0.2 mg l−1, and has a mean standard deviation of 0.073 and an R2 value of 0.999. The results represent great potential of the proposed portable device as an excellent analytical tool for POC colorimetric analysis and offer broad accessibility in resource-limited settings. PMID:29291093
NASA Astrophysics Data System (ADS)
Zhao, Tianzhuo; Fan, Zhongwei; Lian, Fuqiang; Liu, Yang; Lin, Weiran; Mo, Zeqiang; Nie, Shuzhen; Wang, Pu; Xiao, Hong; Li, Xin; Zhong, Qixiu; Zhang, Hongbo
2017-11-01
Laser-induced breakdown spectroscopy (LIBS) utilizing an echelle spectrograph-ICCD system is employed for on-line analysis of elements concentration in a vacuum induction melting workshop. Active temperature stabilization of echelle spectrometer is implemented specially for industrial environment applications. The measurement precision is further improved by monitoring laser parameters, such as pulse energy, spatial and temporal profiles, in real time, and post-selecting laser pulses with specific pulse energies. Experimental results show that major components of nickel-based alloys are stable, and can be well detected. By using internal standard method, calibration curves for chromium and aluminum are obtained for quantitative determination, with determination coefficient (relative standard deviation) to be 0.9559 (< 2.2%) and 0.9723 (< 2.8%), respectively.
Hyperferritinemia in Dogs with Splenic Hemangiosarcoma
CHIKAZAWA, Seishiro; HORI, Yasutomo; HOSHI, Fumio; KANAI, Kazutaka; ITO, Naoyuki; HIGUCHI, Seiichi
2013-01-01
ABSTRACT Serum ferritin concentration increases in dogs in association with various diseases. In this study, we measured serum ferritin levels in dogs with splenic masses, using a sandwich ELISA assay. Eleven dogs with hemangiosarcoma (HSA), six with hematoma, 1 with hemangioma and 3 with lymphoma were enrolled. All dogs with HSA had serum ferritin concentrations above the normal limit (1,357 ng/ml, mean + 2× standard deviation of normal). Increased serum ferritin concentrations have also been observed in few cases of hematoma, hemangioma and lymphoma. Therefore, hyperferritinemia is not specific for splenic HSA, but may have clinical usefulness as a sensitive test for the disease. Further evaluation of serum ferritin concentrations in dogs with splenic HSA is needed. PMID:23803459
Hyperferritinemia in dogs with splenic hemangiosarcoma.
Chikazawa, Seishiro; Hori, Yasutomo; Hoshi, Fumio; Kanai, Kazutaka; Ito, Naoyuki; Higuchi, Seiichi
2013-11-01
Serum ferritin concentration increases in dogs in association with various diseases. In this study, we measured serum ferritin levels in dogs with splenic masses, using a sandwich ELISA assay. Eleven dogs with hemangiosarcoma (HSA), six with hematoma, 1 with hemangioma and 3 with lymphoma were enrolled. All dogs with HSA had serum ferritin concentrations above the normal limit (1,357 ng/ml, mean + 2× standard deviation of normal). Increased serum ferritin concentrations have also been observed in few cases of hematoma, hemangioma and lymphoma. Therefore, hyperferritinemia is not specific for splenic HSA, but may have clinical usefulness as a sensitive test for the disease. Further evaluation of serum ferritin concentrations in dogs with splenic HSA is needed.
Exploring Students' Conceptions of the Standard Deviation
ERIC Educational Resources Information Center
delMas, Robert; Liu, Yan
2005-01-01
This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2012 CFR
2012-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2014 CFR
2014-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2011 CFR
2011-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2013 CFR
2013-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation
ERIC Educational Resources Information Center
Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann
2017-01-01
This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2010 CFR
2010-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.6 - Tolerances for moisture meters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat Mid ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat High ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat...
Free tropospheric measurements of CS2 over a 45 deg N to 45 deg S latitude range
NASA Technical Reports Server (NTRS)
Tucker, B. J.; Maroulis, P. J.; Bandy, A. R.
1985-01-01
The mean value obtained from 52 free tropospheric measurements of CS2 over the 45 deg N-45 deg S latitude range was 5.7 pptv, with standard deviation and standard error of 1.9 and 0.3 pptv, respectively. Large fluctuations in the CS2 concentration are observed which reflect the apparent short atmospheric residence time and inhomogeneities in the surface sources of CS2. The amounts of CS2 in the Northern and Southern Hemispheres are statistically equal.
NASA Technical Reports Server (NTRS)
Khristova, R.; Vanmen, M.
1986-01-01
Based on considerations of principles and experimental data, the interference of sulfate ions in poteniometric titration of EDTA with FeCl3 was confirmed. The method of back complexometric titration of molybdenum of Nonova and Gasheva was improved by replacing hydrazine sulfate with hydrazine hydrochloride for reduction of Mo(VI) to Mo(V). The method can be used for one to tenths of mg of molybdenum with 0.04 mg standard deviation. The specific method of determination of molybdenum in molybdenite concentrates is presented.
Simulated laser fluorosensor signals from subsurface chlorophyll distributions
NASA Technical Reports Server (NTRS)
Venable, D. D.; Khatun, S.; Punjabi, A.; Poole, L.
1986-01-01
A semianalytic Monte Carlo model has been used to simulate laser fluorosensor signals returned from subsurface distributions of chlorophyll. This study assumes the only constituent of the ocean medium is the common coastal zone dinoflagellate Prorocentrum minimum. The concentration is represented by Gaussian distributions in which the location of the distribution maximum and the standard deviation are variable. Most of the qualitative features observed in the fluorescence signal for total chlorophyll concentrations up to 1.0 microg/liter can be accounted for with a simple analytic solution assuming a rectangular chlorophyll distribution function.
Mooij, Anne H; Frauscher, Birgit; Amiri, Mina; Otte, Willem M; Gotman, Jean
2016-12-01
To assess whether there is a difference in the background activity in the ripple band (80-200Hz) between epileptic and non-epileptic channels, and to assess whether this difference is sufficient for their reliable separation. We calculated mean and standard deviation of wavelet entropy in 303 non-epileptic and 334 epileptic channels from 50 patients with intracerebral depth electrodes and used these measures as predictors in a multivariable logistic regression model. We assessed sensitivity, positive predictive value (PPV) and negative predictive value (NPV) based on a probability threshold corresponding to 90% specificity. The probability of a channel being epileptic increased with higher mean (p=0.004) and particularly with higher standard deviation (p<0.0001). The performance of the model was however not sufficient for fully classifying the channels. With a threshold corresponding to 90% specificity, sensitivity was 37%, PPV was 80%, and NPV was 56%. A channel with a high standard deviation of entropy is likely to be epileptic; with a threshold corresponding to 90% specificity our model can reliably select a subset of epileptic channels. Most studies have concentrated on brief ripple events. We showed that background activity in the ripple band also has some ability to discriminate epileptic channels. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
Sharma, P; Bhargava, M; Sukhachev, D; Datta, S; Wattal, C
2014-02-01
Tropical febrile illnesses such as malaria and dengue are challenging to differentiate clinically. Automated cellular indices from hematology analyzers may afford a preliminary rapid distinction. Blood count and VCS parameters from 114 malaria patients, 105 dengue patients, and 105 febrile controls without dengue or malaria were analyzed. Statistical discriminant functions were generated, and their diagnostic performances were assessed by ROC curve analysis. Three statistical functions were generated: (i) malaria-vs.-controls factor incorporating platelet count and standard deviations of lymphocyte volume and conductivity that identified malaria with 90.4% sensitivity, 88.6% specificity; (ii) dengue-vs.-controls factor incorporating platelet count, lymphocyte percentage and standard deviation of lymphocyte conductivity that identified dengue with 81.0% sensitivity and 77.1% specificity; and (iii) febrile-controls-vs.-malaria/dengue factor incorporating mean corpuscular hemoglobin concentration, neutrophil percentage, mean lymphocyte and monocyte volumes, and standard deviation of monocyte volume that distinguished malaria and dengue from other febrile illnesses with 85.1% sensitivity and 91.4% specificity. Leukocyte abnormalities quantitated by automated analyzers successfully identified malaria and dengue and distinguished them from other fevers. These economic discriminant functions can be rapidly calculated by analyzer software programs to generate electronic flags to trigger-specific testing. They could potentially transform diagnostic approaches to tropical febrile illnesses in cost-constrained settings. © 2013 John Wiley & Sons Ltd.
Determination of Trace lead (II) by Resonance Light Scattering Based on Pb (II)-KI-MG System
NASA Astrophysics Data System (ADS)
Chen, Ninghua; Yang, Yingchun; Hao, Shuai; Li, Yangmin
2018-01-01
In pH=3.0 weak acidic solution, it is found that Pb2+ can react with I-to form [PbI4]2-, and it further reacted with MG to form ion-association complex. As a result, the new spectra of RLS appeared and their intensities enhanced greatly. Accordingly, a new method developed for the determination of Pb (II).The appropriate reaction conditions were optimized through experiments. The results show that a strong and stable resonance scattering spectra emerge at the wavelength of 338 nm. The resonance light scattering strength (ΔIRLS) has good linear relationship with the concentration of Pb (II) in the range of 0.2 μg/mL ~ 1.0 μg/mL. The detection limits (LOD) is 0.0155 μg/mL. The relative standard deviation (RSD) is 3.61% (n=11) for the determination of 0.6 μg/mL Pb (II) standard solution. And this method was successfully applied to the determination of three environmental water samples (nongfu spring, tap water, laboratory wastewater). Results illustrate that the addition standard recovery are 80%~107% with relative standard deviation (RSD) between 1.8% to 4.6%.
Kong, Xianghong; He, Qiang; Yue, Aishan; Wu, Shuangmin; Li, Jianhua
2010-06-01
An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of arbutin in apple juice concentrate. Samples were diluted with water, then cleaned-up with a PS-DVB column. Quantitation was carried out using an external standard method. UPLC was performed on an Eclipse Plus C, column (100 mm x 2.1 mm, 1.8 microm) using a gradient solvent system (methanol-water). MS/MS was performed with multiple reaction monitoring (MRM) mode. The detection limit of arbutin was 0.02 mg/L. The method showed good linear relationship at the range of 0.04-2.0 mg/L. The recoveries ranged from 75.2% to 102.7% with relative standard deviations (RSDs) less than 8.9%. The method is simple, fast and sensitive. It's suitable for quantitative and qualitative analysis of arbutin in apple juice concentrate.
Visualizing the Sample Standard Deviation
ERIC Educational Resources Information Center
Sarkar, Jyotirmoy; Rashid, Mamunur
2017-01-01
The standard deviation (SD) of a random sample is defined as the square-root of the sample variance, which is the "mean" squared deviation of the sample observations from the sample mean. Here, we interpret the sample SD as the square-root of twice the mean square of all pairwise half deviations between any two sample observations. This…
Transboundary atmospheric lead pollution.
Erel, Yigal; Axelrod, Tamar; Veron, Alain; Mahrer, Yitzak; Katsafados, Petros; Dayan, Uri
2002-08-01
A high-temporal resolution collection technique was applied to refine aerosol sampling in Jerusalem, Israel. Using stable lead isotopes, lead concentrations, synoptic data, and atmospheric modeling, we demonstrate that lead detected in the atmosphere of Jerusalem is not only anthropogenic lead of local origin but also lead emitted in other countries. Fifty-seven percent of the collected samples contained a nontrivial fraction of foreign atmospheric lead and had 206Pb/207Pb values which deviated from the local petrol-lead value (206Pb/207Pb = 1.113) by more than two standard deviations (0.016). Foreign 206Pb/207Pb values were recorded in Jerusalem on several occasions. The synoptic conditions on these dates and reported values of the isotopic composition of lead emitted in various countries around Israel suggest that the foreign lead was transported to Jerusalem from Egypt, Turkey, and East Europe. The average concentration of foreign atmospheric lead in Jerusalem was 23 +/- 17 ng/m3, similar to the average concentration of local atmospheric lead, 21 +/- 18 ng/ m3. Hence, the load of foreign atmospheric lead is similar to the load of local atmospheric lead in Jerusalem.
Dopkins, Stephen; Varner, Kaitlin; Hoyer, Darin
2017-10-01
In word recognition semantic priming of test words increased the false-alarm rate and the mean of confidence ratings to lures. Such priming also increased the standard deviation of confidence ratings to lures and the slope of the z-ROC function, suggesting that the priming increased the standard deviation of the lure evidence distribution. The Unequal Variance Signal Detection (UVSD) model interpreted the priming as increasing the standard deviation of the lure evidence distribution. Without additional parameters the Dual Process Signal Detection (DPSD) model could only accommodate the results by fitting the data for related and unrelated primes separately, interpreting the priming, implausibly, as decreasing the probability of target recollection (DPSD). With an additional parameter, for the probability of false (lure) recollection the model could fit the data for related and unrelated primes together, interpreting the priming as increasing the probability of false recollection. These results suggest that DPSD estimates of target recollection probability will decrease with increases in the lure confidence/evidence standard deviation unless a parameter is included for false recollection. Unfortunately the size of a given lure confidence/evidence standard deviation relative to other possible lure confidence/evidence standard deviations is often unspecified by context. Hence the model often has no way of estimating false recollection probability and thereby correcting its estimates of target recollection probability.
Holloway, Cpt Monica M; Jurina, Cpt Shannan L; Orszag, Cpt Joshua D; Bragdon, Lt George R; Green, Lt Rustin D; Garcia-Blanco, Jose C; Benham, Brian E; Adams, Ltc Timothy S; Johnson, Don
2016-01-01
To compare the effects of amiodarone administration by humerus intraosseous (HIO) and intravenous (IV) routes on return of spontaneous circulation (ROSC), time to maximum concentration (Tmax), maximum plasma drug concentration (Cmax), time to ROSC, and mean concentrations over time in a hypovolemic cardiac arrest model. Prospective, between subjects, randomized experimental design. TriService Research Facility. Yorkshire-cross swine (n = 28). Swine were anesthetized and placed into cardiac arrest. After 2 minutes, cardiopulmonary resuscitation was initiated. After an additional 2 minutes, amiodarone 300 mg was administered via the HIO or the IV route. Blood samples were collected over 5 minutes. The samples were analyzed using high-performance liquid chromatography tandem mass spectrometry. ROSC, Tmax, Cmax, time to ROSC, and mean concentrations over time. There was no difference in ROSC between the HIO and IV groups; each had five achieve ROSC and two that did not (p = 1). There was no difference in Tmax (p = 0.501) or in Cmax between HIO and IV groups (p = 0.232). Means ± standard deviations in seconds were 94.3 ± 78.3 compared to 115.7 ± 87.3 in the IV versus HIO groups, respectively. The mean ± standard deviation in nanograms per milliliter for the HIO was 49,041 ± 21,107 and 74,258 ± 33,176 for the IV group. There were no significant differences between the HIO and IV groups relative to time to ROSC (p = 0.220). A repeated analysis of variance indicated that there were no significant differences between the groups relative to concentrations over time (p > 0.05). The humerus intraosseous provides rapid and reliable access to administer life-saving medications during cardiac arrest.
Calcium carbonate nucleation in an alkaline lake surface water, Pyramid Lake, Nevada, USA
Reddy, Michael M.; Hoch, Anthony
2012-01-01
Calcium concentration and calcite supersaturation (Ω) needed for calcium carbonate nucleation and crystal growth in Pyramid Lake (PL) surface water were determined during August of 1997, 2000, and 2001. PL surface water has Ω values of 10-16. Notwithstanding high Ω, calcium carbonate growth did not occur on aragonite single crystals suspended PL surface water for several months. However, calcium solution addition to PL surface-water samples caused reproducible calcium carbonate mineral nucleation and crystal growth. Mean PL surface-water calcium concentration at nucleation was 2.33 mM (n = 10), a value about nine times higher than the ambient PL surface-water calcium concentration (0.26 mM); mean Ω at nucleation (109 with a standard deviation of 8) is about eight times the PL surface-water Ω. Calcium concentration and Ω regulated the calcium carbonate formation in PL nucleation experiments and surface water. Unfiltered samples nucleated at lower Ω than filtered samples. Calcium concentration and Ω at nucleation for experiments in the presence of added particles were within one standard deviation of the mean for all samples. Calcium carbonate formation rates followed a simple rate expression of the form, rate (mM/min) = A (Ω) + B. The best fit rate equation "Rate (Δ mM/Δ min) = -0.0026 Ω + 0.0175 (r = 0.904, n = 10)" was statistically significant at greater than the 0.01 confidence level and gives, after rearrangement, Ω at zero rate of 6.7. Nucleation in PL surface water and morphology of calcium carbonate particles formed in PL nucleation experiments and in PL surface-water samples suggest crystal growth inhibition by multiple substances present in PL surface water mediates PL calcium carbonate formation, but there is insufficient information to determine the chemical nature of all inhibitors.
Calcium Carbonate Nucleation in an Alkaline Lake Surface Water, Pyramid Lake, Nevada, USA
Reddy, M.M.; Hoch, A.
2012-01-01
Calcium concentration and calcite supersaturation (??) needed for calcium carbonate nucleation and crystal growth in Pyramid Lake (PL) surface water were determined during August of 1997, 2000, and 2001. PL surface water has ?? values of 10-16. Notwithstanding high ??, calcium carbonate growth did not occur on aragonite single crystals suspended PL surface water for several months. However, calcium solution addition to PL surface-water samples caused reproducible calcium carbonate mineral nucleation and crystal growth. Mean PL surface-water calcium concentration at nucleation was 2.33 mM (n = 10), a value about nine times higher than the ambient PL surface-water calcium concentration (0.26 mM); mean ?? at nucleation (109 with a standard deviation of 8) is about eight times the PL surface-water ??. Calcium concentration and ?? regulated the calcium carbonate formation in PL nucleation experiments and surface water. Unfiltered samples nucleated at lower ?? than filtered samples. Calcium concentration and ?? at nucleation for experiments in the presence of added particles were within one standard deviation of the mean for all samples. Calcium carbonate formation rates followed a simple rate expression of the form, rate (mM/min) = A (??) + B. The best fit rate equation "Rate (?? mM/?? min) = -0.0026 ?? + 0.0175 (r = 0.904, n = 10)" was statistically significant at greater than the 0.01 confidence level and gives, after rearrangement, ?? at zero rate of 6.7. Nucleation in PL surface water and morphology of calcium carbonate particles formed in PL nucleation experiments and in PL surface-water samples suggest crystal growth inhibition by multiple substances present in PL surface water mediates PL calcium carbonate formation, but there is insufficient information to determine the chemical nature of all inhibitors. ?? 2011 U.S. Government.
Aqueous and vitreous penetration of linezolid and levofloxacin after oral administration.
George, Jomy M; Fiscella, Richard; Blair, Michael; Rodvold, Keith; Ulanski, Lawrence; Stokes, John; Blair, Norman; Pontiggia, Laura
2010-12-01
To evaluate the time course of drug concentrations achieved in aqueous (AQ), vitreous (V), and serum (S) compartments after oral administration of linezolid and levofloxacin. Randomized, clinical trial. Clinical practice. Sixteen patients (16 eyes) undergoing vitrectomy who had not had a prior pars plana vitrectomy in the study eye were randomly assigned to one of 4 groups. AQ, V, and S samples were obtained from all subjects after single concomitant doses of linezolid 600 mg and levofloxacin 750 mg between 1 and 12 h before the procedure: group A = 1-3 h; group B = 3-6 h; group C = 6-9 h; group D = 9-12 h. AQ, V, and S concentrations of linezolid and levofloxacin. Overall mean concentrations ± standard deviation (μg/mL) achieved by linezolid in AQ, V, and S compartments were 3.32 ± 2.06, 2.98 ± 1.87, and 7.91 ± 3.94, respectively. Overall mean concentrations ±standard deviation (μg/mL) achieved by levofloxacin in AQ, V, and S compartments were 2.19 ± 1.92, 1.95 ± 1.27, and 7.38 ± 3.47, respectively. Single concomitant doses of linezolid and levofloxacin achieved AQ and V concentrations above the minimum inhibitory concentration for 90% of common ocular gram-positive and gram-negative pathogens up to 12 h after administration. The combination of linezolid and levofloxacin represents a viable option for the prophylaxis and management of endophthalmitis.
Down-Looking Interferometer Study II, Volume I,
1980-03-01
g(standard deviation of AN )(standard deviation of(3) where T’rm is the "reference spectrum", an estimate of the actual spectrum v gv T ’V Cgv . If jpj...spectrum T V . cgv . According to Eq. (2), Z is the standard deviation of the observed contrast spectral radiance AN divided by the effective rms system
40 CFR 61.207 - Radium-226 sampling and measurement procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... B, Method 114. (3) Calculate the mean, x 1, and the standard deviation, s 1, of the n 1 radium-226... owner or operator of a phosphogypsum stack shall report the mean, standard deviation, 95th percentile..., Method 114. (4) Recalculate the mean and standard deviation of the entire set of n 2 radium-226...
Briehl, Margaret M; Nelson, Mark A; Krupinski, Elizabeth A; Erps, Kristine A; Holcomb, Michael J; Weinstein, John B; Weinstein, Ronald S
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, "Mechanisms of Human Disease." Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master's: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises.
Briehl, Margaret M.; Nelson, Mark A.; Krupinski, Elizabeth A.; Erps, Kristine A.; Holcomb, Michael J.; Weinstein, John B.
2016-01-01
Faculty members from the Department of Pathology at The University of Arizona College of Medicine-Tucson have offered a 4-credit course on enhanced general pathology for graduate students since 1996. The course is titled, “Mechanisms of Human Disease.” Between 1997 and 2016, 270 graduate students completed Mechanisms of Human Disease. The students came from 21 programs of study. Analysis of Variance, using course grade as the dependent and degree, program, gender, and year (1997-2016) as independent variables, indicated that there was no significant difference in final grade (F = 0.112; P = .8856) as a function of degree (doctorate: mean = 89.60, standard deviation = 5.75; master’s: mean = 89.34, standard deviation = 6.00; certificate program: mean = 88.64, standard deviation = 8.25), specific type of degree program (F = 2.066, P = .1316; life sciences: mean = 89.95, standard deviation = 6.40; pharmaceutical sciences: mean = 90.71, standard deviation = 4.57; physical sciences: mean = 87.79, standard deviation = 5.17), or as a function of gender (F = 2.96, P = .0865; males: mean = 88.09, standard deviation = 8.36; females: mean = 89.58, standard deviation = 5.82). Students in the physical and life sciences performed equally well. Mechanisms of Human Disease is a popular course that provides students enrolled in a variety of graduate programs with a medical school-based course on mechanisms of diseases. The addition of 2 new medically oriented Master of Science degree programs has nearly tripled enrollment. This graduate level course also potentially expands the interdisciplinary diversity of participants in our interprofessional education and collaborative practice exercises. PMID:28725783
Determination of antibacterial flomoxef in serum by capillary electrophoresis.
Kitahashi, Toshihiro; Furuta, Itaru
2003-04-01
A determination method of flomoxef (FMOX) concentration in serum by capillary electrophoresis is developed. Serum samples are extracted with acetonitrile. After pretreatment, they are separated in a fused-silica capillary tube with a 25 mM borate buffer (pH 10.0) as a running buffer that contains 50mM sodium dodecyl sulfate. The FMOX and acetaminophen (internal standard) are detected by UV absorbance at 200 nm. Linearity (0-200 mg/L) is good, and the minimum limit of detection is 1.0 mg/L (S/N = 3). The relative standard deviations of intra- and interassay variability are 1.60-4.78% and 2.10-3.31%, respectively, and the recovery rate is 84-98%. This method can be used for determination of FMOX concentration in serum.
Metal Ion Sensor with Catalytic DNA in a Nanofluidic Intelligent Processor
2011-12-01
attributed to decreased diffusion and less active DNAzyme complex because of pore constraints. Uncleavable Alexa546 intensity is shown in gray ...is shown in gray , cleavable fluorescein in green, and the ratio of Fl/Alexa in red. Error bars represent one standard deviation of four independent...higher concentrations inhibiting cleaved fragment release. Uncleavable Alexa 546 intensity is shown in gray , cleavable fluorescein in green, and the
Effects of Neighborhood Resources on Aggressive and Delinquent Behaviors Among Urban Youths
Molnar, Beth E.; Cerda, Magdalena; Roberts, Andrea L.; Buka, Stephen L.
2008-01-01
Objectives. We sought to identify neighborhood-level resources associated with lower levels of aggression and delinquency among youths aged 9–15 years at baseline after accounting for risk factors and other types of resources. Methods. Data were derived from the Project on Human Development in Chicago Neighborhoods, which focused on 2226 ethnically diverse, urban youths, their caregivers, and the 80 neighborhoods in which they resided at baseline. Results. Living in a neighborhood with a higher concentration of organizations or services serving young people and adults was associated with lower levels of aggression (odds ratio [OR]=0.9; 95% confidence interval [CI]=0.8, 1.0); living in such a neighborhood also moderated family, peer, and mentor resources. For example, the presence of well-behaved peers was associated with lower levels of aggression among youths living in neighborhoods where the concentration of organizations and services was at least 1 standard deviation above the mean; the association was less strong among youths living in neighborhoods with organizations and services 1 standard deviation below the mean or less. Conclusions. Certain family, peer, and mentoring resources may confer benefits only in the presence of neighborhood resources. Increasing neighborhood resources should be considered in interventions designed to reduce urban youths’ involvement in violence. PMID:17901441
Moving to Opportunity and Mental Health: Exploring the Spatial Context of Neighborhood Effects
Arcaya, Mariana C; Diez Roux, Ana V.
2016-01-01
Studies of housing mobility and neighborhood effects on health often treat neighborhoods as if they were isolated islands. This paper argues that conceptualizing neighborhoods as part of the wider spatial context within which they are embedded may be key in advancing our understanding of the role of local context in the life of urban dwellers. Analyses are based on mental health and neighborhood context measurements taken on over 3,000 low-income families who participated in the Moving to Opportunity for Fair Housing Demonstration Program (MTO), a large field experiment in five major U.S. cities. Results from analyses of two survey waves combined with Census data at different geographic scales indicate that assignment to MTO's experimental condition of neighborhood poverty <10% significantly decreased average exposure to immediate and surrounding neighborhood disadvantage by 97% and 59% of a standard deviation, respectively, relative to the control group. Escaping concentrated disadvantage in either the immediate neighborhood or the surrounding neighborhood, but not both, was insufficient to make a difference for mental health. Instead, the results suggest that improving both the immediate and surrounding neighborhoods significantly benefits mental health. Compared to remaining in concentrated disadvantage in the immediate and surrounding neighborhood, escaping concentrated disadvantage in both the immediate and surrounding neighborhood on average over the study duration as a result of the intervention predicts an increase of 25% of a standard deviation in the composite mental health scores. PMID:27337349
Garbarino, John R.; Struzeski, Tedmund M.
1998-01-01
Inductively coupled plasma-optical emission spectrometry (ICP-OES) and inductively coupled plasma-mass spectrometry (ICP-MS) can be used to determine 26 elements in whole-water digests. Both methods have distinct advantages and disadvantages--ICP-OES is capable of analyzing samples with higher elemental concentrations without dilution, however, ICP-MS is more sensitive and capable of determining much lower elemental concentrations. Both techniques gave accurate results for spike recoveries, digested standard reference-water samples, and whole-water digests. Average spike recoveries in whole-water digests were 100 plus/minus 10 percent, although recoveries for digests with high dissolved-solid concentrations were lower for selected elements by ICP-MS. Results for standard reference-water samples were generally within 1 standard deviation of hte most probable values. Statistical analysis of the results from 43 whole-water digest indicated that there was no significant difference among ICP-OES, ICP-MS, and former official methods of analysis for 24 of the 26 elements evaluated.
A Note on Standard Deviation and Standard Error
ERIC Educational Resources Information Center
Hassani, Hossein; Ghodsi, Mansoureh; Howell, Gareth
2010-01-01
Many students confuse the standard deviation and standard error of the mean and are unsure which, if either, to use in presenting data. In this article, we endeavour to address these questions and cover some related ambiguities about these quantities.
Edstein, Michael D; Kocisko, David A; Walsh, Douglas S; Eamsila, Chirapa; Charles, Bruce G; Rieckmann, Karl H
2003-12-15
We measured plasma tafenoquine concentrations in Thai soldiers given a monthly regimen of tafenoquine to determine whether these concentrations adequately suppressed malarial infections on the Thai-Cambodian border. After receiving a treatment course of artesunate and doxycycline, 104 male soldiers were administered a loading dose of tafenoquine (400 mg daily for 3 days), followed by tafenoquine monthly (400 mg every 4 weeks) for 5 months. Consecutive monthly mean (+/- standard deviation) trough plasma tafenoquine concentrations were 223+/-41, 127+/-29, 157+/-51, 120+/-24, and 88+/-20 ng/mL. Only 1 soldier developed malaria during the study. At the time of malaria diagnosis, his plasma tafenoquine concentration was 40 ng/mL, which was approximately 3-fold lower than the trough concentrations of the other soldiers. Although low tafenoquine concentrations appear to be uncommon, additional investigations are needed to determine the relationship between plasma tafenoquine concentrations and suppression of malaria.
Standardization of computer-assisted semen analysis using an e-learning application.
Ehlers, J; Behr, M; Bollwein, H; Beyerbach, M; Waberski, D
2011-08-01
Computer-assisted semen analysis (CASA) is primarily used to obtain accurate and objective kinetic sperm measurements. Additionally, AI centers use computer-assessed sperm concentration in the sample as a basis for calculating the number of insemination doses available from a given ejaculate. The reliability of data is often limited and results can vary even when the same CASA systems with identical settings are used. The objective of the present study was to develop a computer-based training module for standardized measurements with a CASA system and to evaluate its training effect on the quality of the assessment of sperm motility and concentration. A digital versatile disc (DVD) has been produced showing the standardization of sample preparation and analysis with the CASA system SpermVision™ version 3.0 (Minitube, Verona, WI, USA) in words, pictures, and videos, as well as the most probable sources of error. Eight test persons educated in spermatology, but with different levels of experience with the CASA system, prepared and assessed 10 aliquots from one prediluted bull ejaculate using the same CASA system and laboratory equipment before and after electronic learning (e-learning). After using the e-learning application, the coefficient of variation was reduced on average for the sperm concentration from 26.1% to 11.3% (P ≤ 0.01), and for motility from 5.8% to 3.1% (P ≤ 0.05). For five test persons, the difference in the coefficient of variation before and after use of the e-learning application was significant (P ≤ 0.05). Individual deviations of means from the group mean before e-learning were reduced compared with individual deviations from the group mean after e-learning. According to a survey, the e-learning application was highly accepted by users. In conclusion, e-learning presents an effective, efficient, and accepted tool for improvement of the precision of CASA measurements. This study provides a model for the standardization of other laboratory procedures using e-learning. Copyright © 2011 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhai, Qing-zhou; Zhang, Xiao-xia; Huang, Chong
2008-03-01
A simple and sensitive kinetic-spectrophotometric method is developed for the determination of trace vanadium(V), based on the catalytic effect of vanadium(V) on the oxidation of DBM-arsenazo by potassium bromate in 0.0138 mol l -1 phosphoric acid medium and at 100 °C in the presence of citric acid as activator. The absorbance is measured at 528 nm with the fixed-time method. The optimization of the operating conditions regarding concentrations of the reagents, temperature and interferences are also investigated. The working curve is linear over the concentration range 0-20 ng ml -1 of vanadium(V) with good precision and accuracy and the detection limit was down to 3.44 ng l -1. The relative standard deviation for a standard solution of 14 ng ml -1 is 0.28% ( n = 11). The apparent activity energies of the catalytic reaction and the non-catalytic reaction are 73.48, 113.5 kJ/mol, respectively. The proposed method proved highly sensitive, selective and relatively rapid for the assay of vanadium at low-level range of 0-20 ng ml -1 without any pre-concentration step. Thw method was applied to the determination of vanadium(V) in steels, rice, flour, cabbage, potato, fish, shrimp and tea samples with satisfactory results. The obtained results for the steel samples were excellent agreement with the standard reference values. The analytical results of the rice, flour, cabbage, potato, fish, shrimp and tea samples were excellent agreement with those of atomic absorption spectrometry. The recovery experiments have been made for the rice, flour, cabbage, potato, fish, shrimp and tea samples except the steels; excellent results were obtained. The relative standard deviations were over the range of 0.18-2.60% and the recoveries were over the range of 98.00-102.4%, respectively. The analytical results obtained were satisfactory.
Paretti, Nicholas; Coes, Alissa L.; Kephart, Christopher M.; Mayo, Justine
2018-03-05
Tumacácori National Historical Park protects the culturally important Mission, San José de Tumacácori, while also managing a portion of the ecologically diverse riparian corridor of the Santa Cruz River. This report describes the methods and quality assurance procedures used in the collection of water samples for the analysis of Escherichia coli (E. coli), microbial source tracking markers, suspended sediment, water-quality parameters, turbidity, and the data collection for discharge and stage; the process for data review and approval is also described. Finally, this report provides a quantitative assessment of the quality of the E. coli, microbial source tracking, and suspended sediment data.The data-quality assessment revealed that bias attributed to field and laboratory contamination was minimal, with E. coli detections in only 3 out of 33 field blank samples analyzed. Concentrations in the field blanks were several orders of magnitude lower than environmental concentrations. The microbial source tracking (MST) field blank was below the detection limit for all MST markers analyzed. Laboratory blanks for E. coli at the USGS Arizona Water Science Center and laboratory blanks for MST markers at the USGS Ohio Water Microbiology Laboratory were all below the detection limit. Irreplicate data for E. coli and suspended sediment indicated that bias was not introduced to the data by combining samples collected using discrete sampling methods with samples collected using automatic sampling methods.The split and sequential E. coli replicate data showed consistent analytical variability and a single equation was developed to explain the variability of E. coli concentrations. An additional analysis of analytical variability for E. coli indicated analytical variability around 18 percent relative standard deviation and no trend was observed in the concentration during the processing and analysis of multiple split-replicates. Two replicate samples were collected for MST and individual markers were compared for a base flow and flood sample. For the markers found in common between the two types of samples, the relative standard deviation for the base flow sample was more than 3 times greater than the markers in the flood sample. Sequential suspended sediment replicates had a relative standard deviation of about 1.3 percent, indicating that environmental and analytical variability was minimal.A holding time review and laboratory study analysis supported the extended holding times required for this investigation. Most concentrations for flood and base-flow samples were within the theoretical variability specified in the most probable number approach suggesting that extended hold times did not overly influence the final concentrations reported.
Bolann, B J; Asberg, A
2004-01-01
The deviation of test results from patients' homeostatic set points in steady-state conditions may complicate interpretation of the results and the comparison of results with clinical decision limits. In this study the total deviation from the homeostatic set point is defined as the maximum absolute deviation for 95% of measurements, and we present analytical quality requirements that prevent analytical error from increasing this deviation to more than about 12% above the value caused by biology alone. These quality requirements are: 1) The stable systematic error should be approximately 0, and 2) a systematic error that will be detected by the control program with 90% probability, should not be larger than half the value of the combined analytical and intra-individual standard deviation. As a result, when the most common control rules are used, the analytical standard deviation may be up to 0.15 times the intra-individual standard deviation. Analytical improvements beyond these requirements have little impact on the interpretability of measurement results.
Rhoderick, George C
2007-04-01
New US federal low-level automobile emission requirements, for example zero-level-emission vehicle (ZLEV), for hydrocarbons and other species, have resulted in the need by manufacturers for new certified reference materials. The new emission requirement for hydrocarbons requires the use, by automobile manufacturing testing facilities, of a 100 nmol mol(-1) propane in air gas standard. Emission-measurement instruments are required, by federal law, to be calibrated with National Institute of Standards and Technology (NIST) traceable reference materials. Because a NIST standard reference material (SRM) containing 100 nmol mol(-1) propane was not available, the US Environmental Protection Agency (EPA) and the Automobile Industry/Government Emissions Research Consortium (AIGER) requested that NIST develop such an SRM. A cylinder lot of 30 gas mixtures containing 100 nmol mol(-1) propane in air was prepared in 6-L aluminium gas cylinders by a specialty gas company and delivered to the Gas Metrology Group at NIST. Another mixture, contained in a 30-L aluminium cylinder and included in the lot, was used as a lot standard (LS). Using gas chromatography with flame-ionization detection all 30 samples were compared to the LS to obtain the average of six peak-area ratios to the LS for each sample with standard deviations of <0.31%. The average sample-to-LS ratio determinations resulted in a range of 0.9828 to 0.9888, a spread of 0.0060, which corresponds to a relative standard deviation of 0.15% of the average for all 30 samples. NIST developed its first set of five propane in air primary gravimetric standards covering a concentration range 91 to 103 nmol mol(-1) with relative uncertainties of 0.15%. This new suite of propane gravimetric standards was used to analyze and assign a concentration value to the SRM LS. On the basis of these data each SRM sample was individually certified, furnishing the desired relative expanded uncertainty of +/-0.5%. Because automobile companies use total hydrocarbons to make their measurements, it was also vital to assign a methane concentration to the SRM samples. Some of the SRM samples were analyzed and found to contain 1.2 nmol mol(-1) methane. Twenty-five of the samples were certified and released as SRM 2765.
Infrared spectroscopy for the determination of hydrocarbon types in jet fuels
NASA Technical Reports Server (NTRS)
Buchar, C. S.
1981-01-01
The concentration of hydrocarbon types in conventional jet fuels and synfuels can be measured using a computerized infrared spectrophotometer. The computerized spectrophotometer is calibrated using a fuel of known aromatic and olefinic content. Once calibration is completed, other fuels can be rapidly analyzed using an analytical program built into the computer. The concentration of saturates can be calculated as 100 percent minus the sum of the aromatic and olefinic concentrations. The analysis of a number of jet fuels produced an average standard deviation of 1.76 percent for aromatic types and one of 3.99 percent for olefinic types. Other substances such as oils and organic mixtures can be analyzed for their hydrocarbon content.
NASA Astrophysics Data System (ADS)
Yefimova, Svetlana L.; Rekalo, Andrey M.; Gnap, Bogdan A.; Viagin, Oleg G.; Sorokin, Alexander V.; Malyukin, Yuri V.
2014-09-01
In the present study, we analyze the efficiency of Electronic Excitation Energy Transfer (EEET) between two dyes, an energy donor (D) and acceptor (A), concentrated in structurally heterogeneous media (surfactant micelles, liposomes, and porous SiO2 matrices). In all three cases, highly effective EEET in pairs of dyes has been found and cannot be explained by Standard Förster-type theory for homogeneous solutions. Two independent approaches based on the analysis of either the D relative quantum yield () or the D fluorescence decay have been used to study the deviation of experimental results from the theoretical description of EEET process. The observed deviation is quantified by the apparent fractal distribution of molecules parameter . We conclude that the highly effective EEET observed in the nano-scale media under study can be explained by both forced concentration of the hydrophobic dyes within nano-volumes and non-uniform cluster-like character of the distribution of D and A dye molecules within nano-volumes.
Code of Federal Regulations, 2010 CFR
2010-01-01
... defined in section 1 of this appendix is as follows: (a) The standard deviation of lateral track errors shall be less than 6.3 NM (11.7 Km). Standard deviation is a statistical measure of data about a mean... standard deviation about the mean encompasses approximately 68 percent of the data and plus or minus 2...
Lin, P.-S.; Chiou, B.; Abrahamson, N.; Walling, M.; Lee, C.-T.; Cheng, C.-T.
2011-01-01
In this study, we quantify the reduction in the standard deviation for empirical ground-motion prediction models by removing ergodic assumption.We partition the modeling error (residual) into five components, three of which represent the repeatable source-location-specific, site-specific, and path-specific deviations from the population mean. A variance estimation procedure of these error components is developed for use with a set of recordings from earthquakes not heavily clustered in space.With most source locations and propagation paths sampled only once, we opt to exploit the spatial correlation of residuals to estimate the variances associated with the path-specific and the source-location-specific deviations. The estimation procedure is applied to ground-motion amplitudes from 64 shallow earthquakes in Taiwan recorded at 285 sites with at least 10 recordings per site. The estimated variance components are used to quantify the reduction in aleatory variability that can be used in hazard analysis for a single site and for a single path. For peak ground acceleration and spectral accelerations at periods of 0.1, 0.3, 0.5, 1.0, and 3.0 s, we find that the singlesite standard deviations are 9%-14% smaller than the total standard deviation, whereas the single-path standard deviations are 39%-47% smaller.
Discovery of Finely Structured Dynamic Solar Corona Observed in the Hi-C Telescope
NASA Technical Reports Server (NTRS)
Winebarger, A.; Cirtain, J.; Golub, L.; DeLuca, E.; Savage, S.; Alexander, C.; Schuler, T.
2014-01-01
In the summer of 2012, the High-resolution Coronal Imager (Hi-C) flew aboard a NASA sounding rocket and collected the highest spatial resolution images ever obtained of the solar corona. One of the goals of the Hi-C flight was to characterize the substructure of the solar corona. We therefore examine how the intensity scales from AIA resolution to Hi-C resolution. For each low-resolution pixel, we calculate the standard deviation in the contributing high-resolution pixel intensities and compare that to the expected standard deviation calculated from the noise. If these numbers are approximately equal, the corona can be assumed to be smoothly varying, i.e. have no evidence of substructure in the Hi-C image to within Hi-C's ability to measure it given its throughput and readout noise. A standard deviation much larger than the noise value indicates the presence of substructure. We calculate these values for each low-resolution pixel for each frame of the Hi-C data. On average, 70 percent of the pixels in each Hi-C image show no evidence of substructure. The locations where substructure is prevalent is in the moss regions and in regions of sheared magnetic field. We also find that the level of substructure varies significantly over the roughly 160 s of the Hi-C data analyzed here. This result indicates that the finely structured corona is concentrated in regions of heating and is highly time dependent.
DISCOVERY OF FINELY STRUCTURED DYNAMIC SOLAR CORONA OBSERVED IN THE Hi-C TELESCOPE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winebarger, Amy R.; Cirtain, Jonathan; Savage, Sabrina
In the Summer of 2012, the High-resolution Coronal Imager (Hi-C) flew on board a NASA sounding rocket and collected the highest spatial resolution images ever obtained of the solar corona. One of the goals of the Hi-C flight was to characterize the substructure of the solar corona. We therefore examine how the intensity scales from AIA resolution to Hi-C resolution. For each low-resolution pixel, we calculate the standard deviation in the contributing high-resolution pixel intensities and compare that to the expected standard deviation calculated from the noise. If these numbers are approximately equal, the corona can be assumed to bemore » smoothly varying, i.e., have no evidence of substructure in the Hi-C image to within Hi-C's ability to measure it given its throughput and readout noise. A standard deviation much larger than the noise value indicates the presence of substructure. We calculate these values for each low-resolution pixel for each frame of the Hi-C data. On average, 70% of the pixels in each Hi-C image show no evidence of substructure. The locations where substructure is prevalent is in the moss regions and in regions of sheared magnetic field. We also find that the level of substructure varies significantly over the roughly 160 s of the Hi-C data analyzed here. This result indicates that the finely structured corona is concentrated in regions of heating and is highly time dependent.« less
Yuan, Xiaoyan; Yang, Qianxu
2017-04-01
A method of ultra high performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry was developed for the simultaneous quantification of 11 sesquiterpene lactones in 11 Jerusalem artichoke leaf samples harvested in a number of areas at different periods. The optimal chromatographic conditions were achieved on a ZORBAX Eclipse Plus C 18 column (3.0 × 150 mm, 1.8 μm) with linear gradient elution of methanol and water in 8 min. Quantitative analysis was carried out under selective ion monitoring mode. All of the sesquiterpene lactones showed good linearity (R 2 ≥ 0.9949), repeatability (relative standard deviations < 4.66%), and intra- and interday precisions (relative standard deviations < 4.52%) with an accuracy of 95.24-104.84%. The recoveries measured at three concentration levels varied from 95.07 to 104.87% with relative standard deviations less than 4.9%. The limit of detection and limit of quantitation for this method were 0.89-5.05 and 1.12-44.33 ng/mL, respectively. The results showed that the contents of sesquiterpene lactones varied significantly in the Jerusalem artichoke leaf samples from different areas. Among them, the content of sesquiterpene lactones in the sample collected from Dalian, Liaoning province was the highest and the early flowering period was considered to be the optimal harvest time. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A better norm-referenced grading using the standard deviation criterion.
Chan, Wing-shing
2014-01-01
The commonly used norm-referenced grading assigns grades to rank-ordered students in fixed percentiles. It has the disadvantage of ignoring the actual distance of scores among students. A simple norm-referenced grading via standard deviation is suggested for routine educational grading. The number of standard deviation of a student's score from the class mean was used as the common yardstick to measure achievement level. Cumulative probability of a normal distribution was referenced to help decide the amount of students included within a grade. RESULTS of the foremost 12 students from a medical examination were used for illustrating this grading method. Grading by standard deviation seemed to produce better cutoffs in allocating an appropriate grade to students more according to their differential achievements and had less chance in creating arbitrary cutoffs in between two similarly scored students than grading by fixed percentile. Grading by standard deviation has more advantages and is more flexible than grading by fixed percentile for norm-referenced grading.
Johnson, Craig W; Johnson, Ronald; Kim, Mira; McKee, John C
2009-11-01
During 2004 and 2005 orientations, all 187 and 188 new matriculates, respectively, in two southwestern U.S. nursing schools completed Personal Background and Preparation Surveys (PBPS) in the first predictive validity study of a diagnostic and prescriptive instrument for averting adverse academic status events (AASE) among nursing or health science professional students. One standard deviation increases in PBPS risks (p < 0.05) multiplied odds of first-year or second-year AASE by approximately 150%, controlling for school affiliation and underrepresented minority student (URMS) status. AASE odds one standard deviation above mean were 216% to 250% those one standard deviation below mean. Odds of first-year or second-year AASE for URMS one standard deviation above the 2004 PBPS mean were 587% those for non-URMS one standard deviation below mean. The PBPS consistently and significantly facilitated early identification of nursing students at risk for AASE, enabling proactive targeting of interventions for risk amelioration and AASE or attrition prevention. Copyright 2009, SLACK Incorporated.
Gehlen, Heidrun; Bradaric, Zrinkja
2013-01-01
The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each horse which had been drawn at the same time (blinded samples). Sampling was performed in the morning at the same time. The sampling vacutainers (with and without addition of coagulation and proteinase inhibitors) and postage of the samples was performed according to laboratory standards. In one laboratory the influence of the time of centrifugation (immediately after taking blood versus after one hour) was determined. The samples were processed and analyzed according to laboratory protocols. Determination of ACTH levels was performed using chemiluminescence immunoassay. In total 132 blood samples were analyzed. The results of doubled blood samples of the same horse showed a standard deviation ranging from +/- 6 to +/- 27 pg/ml within the laboratories (Ø 19,29 pg/ml). The standard deviation of the repeatability of the variation coefficient was 13,48%. Blood samples of the same horse resulted in ACTH levels of 121 pg/ml in the first probe and in < 5 pg/ml in the second probe. Standard deviation of measured ACTH values between the laboratories was +/- 26,4 pg/ml (Ø 27,44 pg/ml). The standard deviation of the reproducibility of the variation coefficient was 18,36%. In a 20 year old gelding the lowest ACTH value was 60.9 pg/ml whereas the highest measured value was 108 pg/ml. Immediate centrifugation of blood samples resulted in significantly higher ACTH values at an average of 11.6 pg/ml. The additional use of proteinase inhibitors (aprotinine) showed no influence on ACTH levels in this study.
Demonstration of the Gore Module for Passive Ground Water Sampling
2014-06-01
ix ACRONYMS AND ABBREVIATIONS % RSD percent relative standard deviation 12DCA 1,2-dichloroethane 112TCA 1,1,2-trichloroethane 1122TetCA...Analysis of Variance ROD Record of Decision RSD relative standard deviation SBR Southern Bush River SVOC semi-volatile organic compound...replicate samples had a relative standard deviation ( RSD ) that was 20% or less. For the remaining analytes (PCE, cDCE, and chloroform), at least 70
Development of a Smartphone-based reading system for lateral flow immunoassay.
Lee, Sangdae; Kim, Giyoung; Moon, Jihea
2014-11-01
This study was conducted to develop and evaluate the performance of the Smartphone-based reading system for the lateral flow immunoassay (LFIA). Smartphone-based reading system consists of a Samsung Galaxy S2 Smartphone, Smartphone application, and a LFIA reader. LFIA reader is composed of the close-up lens with a focal length up to 30 mm, white LED light, lithium polymer battery, and main body. The Smartphone application for image acquisition and data analysis was developed on the Android platform. The standard curve was obtained by plotting the measured P(T)/P(c) or A(T)/A(c) ratio versus Salmonella standard concentration. The mean, standard deviation (SD), recovery, and relative standard deviation (RSD) were also calculated using additional experimental results. These data were compared with that obtained from the benchtop LFIA reader. The LOD in both systems was observed with 10(6) CFU/mL. The results show high accuracy and good reproducibility with a RSD less than 10% in the range of 10(6) to 10(9) CFU/mL. Due to the simple structure, good sensitivity, and high accuracy of the Smartphone-based reading system, this system can be substituted for the benchtop LFIA reader for point-of-care medical diagnostics.
Wang, Anxin; Li, Zhifang; Yang, Yuling; Chen, Guojuan; Wang, Chunxue; Wu, Yuntao; Ruan, Chunyu; Liu, Yan; Wang, Yilong; Wu, Shouling
2016-01-01
To investigate the relationship between baseline systolic blood pressure (SBP) and visit-to-visit blood pressure variability in a general population. This is a prospective longitudinal cohort study on cardiovascular risk factors and cardiovascular or cerebrovascular events. Study participants attended a face-to-face interview every 2 years. Blood pressure variability was defined using the standard deviation and coefficient of variation of all SBP values at baseline and follow-up visits. The coefficient of variation is the ratio of the standard deviation to the mean SBP. We used multivariate linear regression models to test the relationships between SBP and standard deviation, and between SBP and coefficient of variation. Approximately 43,360 participants (mean age: 48.2±11.5 years) were selected. In multivariate analysis, after adjustment for potential confounders, baseline SBPs <120 mmHg were inversely related to standard deviation (P<0.001) and coefficient of variation (P<0.001). In contrast, baseline SBPs ≥140 mmHg were significantly positively associated with standard deviation (P<0.001) and coefficient of variation (P<0.001). Baseline SBPs of 120-140 mmHg were associated with the lowest standard deviation and coefficient of variation. The associations between baseline SBP and standard deviation, and between SBP and coefficient of variation during follow-ups showed a U curve. Both lower and higher baseline SBPs were associated with increased blood pressure variability. To control blood pressure variability, a good target SBP range for a general population might be 120-139 mmHg.
Weinstein, Ronald S; Krupinski, Elizabeth A; Weinstein, John B; Graham, Anna R; Barker, Gail P; Erps, Kristine A; Holtrust, Angelette L; Holcomb, Michael J
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school ( F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender ( F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level ( F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student's expectations. One class voted K-12 general pathology their "elective course-of-the-year."
Wan, Xiang; Wang, Wenqian; Liu, Jiming; Tong, Tiejun
2014-12-19
In systematic reviews and meta-analysis, researchers often pool the results of the sample mean and standard deviation from a set of similar clinical trials. A number of the trials, however, reported the study using the median, the minimum and maximum values, and/or the first and third quartiles. Hence, in order to combine results, one may have to estimate the sample mean and standard deviation for such trials. In this paper, we propose to improve the existing literature in several directions. First, we show that the sample standard deviation estimation in Hozo et al.'s method (BMC Med Res Methodol 5:13, 2005) has some serious limitations and is always less satisfactory in practice. Inspired by this, we propose a new estimation method by incorporating the sample size. Second, we systematically study the sample mean and standard deviation estimation problem under several other interesting settings where the interquartile range is also available for the trials. We demonstrate the performance of the proposed methods through simulation studies for the three frequently encountered scenarios, respectively. For the first two scenarios, our method greatly improves existing methods and provides a nearly unbiased estimate of the true sample standard deviation for normal data and a slightly biased estimate for skewed data. For the third scenario, our method still performs very well for both normal data and skewed data. Furthermore, we compare the estimators of the sample mean and standard deviation under all three scenarios and present some suggestions on which scenario is preferred in real-world applications. In this paper, we discuss different approximation methods in the estimation of the sample mean and standard deviation and propose some new estimation methods to improve the existing literature. We conclude our work with a summary table (an Excel spread sheet including all formulas) that serves as a comprehensive guidance for performing meta-analysis in different situations.
Flexner 3.0—Democratization of Medical Knowledge for the 21st Century
Krupinski, Elizabeth A.; Weinstein, John B.; Graham, Anna R.; Barker, Gail P.; Erps, Kristine A.; Holtrust, Angelette L.; Holcomb, Michael J.
2016-01-01
A medical school general pathology course has been reformatted into a K-12 general pathology course. This new course has been implemented at a series of 7 to 12 grade levels and the student outcomes compared. Typically, topics covered mirrored those in a medical school general pathology course serving as an introduction to the mechanisms of diseases. Assessment of student performance was based on their score on a multiple-choice final examination modeled after an examination given to medical students. Two Tucson area schools, in a charter school network, participated in the study. Statistical analysis of examination performances showed that there were no significant differences as a function of school (F = 0.258, P = .6128), with students at school A having an average test scores of 87.03 (standard deviation = 8.99) and school B 86.00 (standard deviation = 8.18; F = 0.258, P = .6128). Analysis of variance was also conducted on the test scores as a function of gender and class grade. There were no significant differences as a function of gender (F = 0.608, P = .4382), with females having an average score of 87.18 (standard deviation = 7.24) and males 85.61 (standard deviation = 9.85). There were also no significant differences as a function of grade level (F = 0.627, P = .6003), with 7th graders having an average of 85.10 (standard deviation = 8.90), 8th graders 86.00 (standard deviation = 9.95), 9th graders 89.67 (standard deviation = 5.52), and 12th graders 86.90 (standard deviation = 7.52). The results demonstrated that middle and upper school students performed equally well in K-12 general pathology. Student course evaluations showed that the course met the student’s expectations. One class voted K-12 general pathology their “elective course-of-the-year.” PMID:28725762
Estimation of the neural drive to the muscle from surface electromyograms
NASA Astrophysics Data System (ADS)
Hofmann, David
Muscle force is highly correlated with the standard deviation of the surface electromyogram (sEMG) produced by the active muscle. Correctly estimating this quantity of non-stationary sEMG and understanding its relation to neural drive and muscle force is of paramount importance. The single constituents of the sEMG are called motor unit action potentials whose biphasic amplitude can interfere (named amplitude cancellation), potentially affecting the standard deviation (Keenan etal. 2005). However, when certain conditions are met the Campbell-Hardy theorem suggests that amplitude cancellation does not affect the standard deviation. By simulation of the sEMG, we verify the applicability of this theorem to myoelectric signals and investigate deviations from its conditions to obtain a more realistic setting. We find no difference in estimated standard deviation with and without interference, standing in stark contrast to previous results (Keenan etal. 2008, Farina etal. 2010). Furthermore, since the theorem provides us with the functional relationship between standard deviation and neural drive we conclude that complex methods based on high density electrode arrays and blind source separation might not bear substantial advantages for neural drive estimation (Farina and Holobar 2016). Funded by NIH Grant Number 1 R01 EB022872 and NSF Grant Number 1208126.
Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.
Bowman, Richard G; Caraway, David; Bentley, Ishmael
2013-01-01
Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.
Accuracy and precision of Legionella isolation by US laboratories in the ELITE program pilot study.
Lucas, Claressa E; Taylor, Thomas H; Fields, Barry S
2011-10-01
A pilot study for the Environmental Legionella Isolation Techniques Evaluation (ELITE) Program, a proficiency testing scheme for US laboratories that culture Legionella from environmental samples, was conducted September 1, 2008 through March 31, 2009. Participants (n=20) processed panels consisting of six sample types: pure and mixed positive, pure and mixed negative, pure and mixed variable. The majority (93%) of all samples (n=286) were correctly characterized, with 88.5% of samples positive for Legionella and 100% of negative samples identified correctly. Variable samples were incorrectly identified as negative in 36.9% of reports. For all samples reported positive (n=128), participants underestimated the cfu/ml by a mean of 1.25 logs with standard deviation of 0.78 logs, standard error of 0.07 logs, and a range of 3.57 logs compared to the CDC re-test value. Centering results around the interlaboratory mean yielded a standard deviation of 0.65 logs, standard error of 0.06 logs, and a range of 3.22 logs. Sampling protocol, treatment regimen, culture procedure, and laboratory experience did not significantly affect the accuracy or precision of reported concentrations. Qualitative and quantitative results from the ELITE pilot study were similar to reports from a corresponding proficiency testing scheme available in the European Union, indicating these results are probably valid for most environmental laboratories worldwide. The large enumeration error observed suggests that the need for remediation of a water system should not be determined solely by the concentration of Legionella observed in a sample since that value is likely to underestimate the true level of contamination. Published by Elsevier Ltd.
Díaz-Quiroz, Carlos A; Francisco Hernández-Chávez, J; Ulloa-Mercado, Gabriela; Gortáres-Moroyoqui, Pablo; Martínez-Macías, Rosario; Meza-Escalante, Edna; Serrano-Palacios, Denisse
2018-06-15
Pig farming is an important activity in the economic development of Mexico with millions of tons of meat produced annually. Antibiotics are used in therapeutic dose to prevent diseases, and sometimes as growth promoters. These compounds are not completely metabolized; they are carried into the environment in its active form at concentrations that could induce antibiotic resistance in bacteria, which could be transferred to human pathogens by horizontal gene transfer. The objective of this work was to develop methods of analysis for simultaneous quantification of the antibiotics Oxytetracycline (OXT), Chlortetracycline (CLT), Enrofloxacin (ENRO) and Ciprofloxacin (CIPRO) by field-amplified sampling injection in capillary zone electrophoresis (FASI-CZE). The method was validated by parameters of (1) linearity, obtaining a lineal range of 0.05 at 1 μg mL -1 for ENRO and CIPRO, and from 0.1 to 1 μg mL -1 for OXT and CLT; (2) precision, obtaining values <5% of standard deviation for CIPRO and ENRO and <10% of standard deviation for OXT and CLT; (3) accuracy, with recovery values from 93 to 115%; (4) selectivity, with values of resolution >2 for the all antibiotics tested. To prove the method, a sample of wastewater from a local pig farm was analyzed, detecting a concentration of 0.140 ± 0.009 for OXT. This concentration was higher than the minimal selective concentration, indicating the point in which resistance to a determined antibiotic could develop. The methods were validated with precision and sensitivity comparable to chromatographic methods, which can be used to analyze wastewater from pig farms directly. Copyright © 2018 Elsevier B.V. All rights reserved.
Long-term observations of the background aerosol at Cabauw, The Netherlands.
Mamali, D; Mikkilä, J; Henzing, B; Spoor, R; Ehn, M; Petäjä, T; Russchenberg, H; Biskos, G
2018-06-01
Long-term measurements of PM 2.5 mass concentrations and aerosol particle size distributions from 2008 to 2015, as well as hygroscopicity measurements conducted over one year (2008-2009) at Cabauw, The Netherlands, are compiled here in order to provide a comprehensive dataset for understanding the trends and annual variabilities of the atmospheric aerosol in the region. PM 2.5 concentrations have a mean value of 14.4μgm -3 with standard deviation 2.1μgm -3 , and exhibit an overall decreasing trend of -0.74μgm -3 year -1 . The highest values are observed in winter and spring and are associated with a shallower boundary layer and lower precipitation, respectively, compared to the rest of the seasons. Number concentrations of particles smaller than 500nm have a mean of 9.2×10 3 particles cm -3 and standard deviation 4.9×10 3 particles cm -3 , exhibiting an increasing trend between 2008 and 2011 and a decreasing trend from 2013 to 2015. The particle number concentrations exhibit highest values in spring and summer (despite the increased precipitation) due to the high occurrence of nucleation-mode particles, which most likely are formed elsewhere and are transported to the observation station. Particle hygroscopicity measurements show that, independently of the air mass origin, the particles are mostly externally mixed with the more hydrophobic mode having a mean hygroscopic parameter κ of 0.1 while for the more hydrophilic mode κ is 0.35. The hygroscopicity of the smaller particles investigated in this work (i.e., particles having diameters of 35nm) appears to increase during the course of the nucleation events, reflecting a change in the chemical composition of the particles. Copyright © 2017 Elsevier B.V. All rights reserved.
Sirisomboon, Panmanas; Chowbankrang, Rawiphan; Williams, Phil
2012-05-01
Near-infrared spectroscopy in diffuse reflection mode was used to evaluate the apparent viscosity of Para rubber field latex and concentrated latex over the wavelength range of 1100 to 2500 nm, using partial least square regression (PLSR). The model with ten principal components (PCs) developed using the raw spectra accurately predicted the apparent viscosity with correlation coefficient (r), standard error of prediction (SEP), and bias of 0.974, 8.6 cP, and -0.4 cP, respectively. The ratio of the SEP to the standard deviation (RPD) and the ratio of the SEP to the range (RER) for the prediction were 4.4 and 16.7, respectively. Therefore, the model can be used for measurement of the apparent viscosity of field latex and concentrated latex in quality assurance and process control in the factory.
NASA Technical Reports Server (NTRS)
King, R. B.; Neustadter, H. E.
1976-01-01
Concentrations of 75 chemical constituents in the airborne particulate matter were measured in Cleveland, Ohio during 1971 and 1972. Daily values, maxima, geometric means and their standard deviations covering a 1-year period (45 to 50 sampling days) at each of 16 sites are presented on microfiche for 60 elements, and for a lesser number of days for 10 polycyclic aromatic hydrocarbon compounds (PAH), the aliphatic hydrocarbon compounds (AH) as a group and carbon. In addition, concentration roses showing directional properties are presented for 39 elements, 10 PAH and the AH as a group. The elements (except carbon) are shown both in terms of concentration and percentage of the suspended particulate matter.
Computer Programs for the Semantic Differential: Further Modifications.
ERIC Educational Resources Information Center
Lawson, Edwin D.; And Others
The original nine programs for semantic differential analysis have been condensed into three programs which have been further refined and augmented. They yield: (1) means, standard deviations, and standard errors for each subscale on each concept; (2) Evaluation, Potency, and Activity (EPA) means, standard deviations, and standard errors; (3)…
Determining a one-tailed upper limit for future sample relative reproducibility standard deviations.
McClure, Foster D; Lee, Jung K
2006-01-01
A formula was developed to determine a one-tailed 100p% upper limit for future sample percent relative reproducibility standard deviations (RSD(R),%= 100s(R)/y), where S(R) is the sample reproducibility standard deviation, which is the square root of a linear combination of the sample repeatability variance (s(r)2) plus the sample laboratory-to-laboratory variance (s(L)2), i.e., S(R) = s(L)2, and y is the sample mean. The future RSD(R),% is expected to arise from a population of potential RSD(R),% values whose true mean is zeta(R),% = 100sigmaR, where sigmaR and mu are the population reproducibility standard deviation and mean, respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colle, R.; Unterweger, M.P.; Hutchinson, J.M.R.
1996-01-01
As part of an international measurement intercomparison of instruments used to measure atmospheric {sup 222}Rn, four participating laboratories made nearly simultaneous measurements of {sup 222}Rn activity concentration in commonly sampled, ambient air over approximately a 2 week period, and three of these four laboratories participated in the measurement comparison of 14 introduced samples with known, but undisclosed (blind) {sup 222}Rn activity concentration. The exercise was conducted in Bermuda in October 1991. The {sup 222}Rn activity concentrations in ambient Bermudian air over the course of the intercomparison ranged from a few hundredths of a Bq {center_dot} m{sup {minus}3} to about 2more » Bq {center_dot} m{sup {minus}3}, while the standardized sample additions covered a range from approximately 2.5 Bq {center_dot} m{sup {minus}3} to 35 Bq {center_dot} m{sup {minus}3}. The overall uncertainty in the latter concentrations was in the general range of 10%, approximating a 3 standard deviation uncertainty interval. The results of the intercomparison indicated that two of the laboratories were within very good agreement with the standard additions, and almost within expected statistical variations. These same two laboratories, however, at lower ambient concentrations, exhibited a systematic difference with an averaged offset of roughly 0.3 Bq {center_dot} m{sup {minus}3}. The third laboratory participating in the measurement of standardized sample additions was systematically low by about 65% to 70%, with respect to the standard addition which was also confirmed in their ambient air concentration measurements. The fourth laboratory, participating in only the ambient measurement part of the intercomparison, was also systematically low by at least 40% with respect to the first two laboratories.« less
Fries, Elke; Klasmeier, Jörg
2009-01-30
Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC-MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [(2)H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L(-1). Calibration was linear in the range of 0.5-208.5 mg L(-1). The detection limit calculated considering the blank value was 0.176 mg L(-1). The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L(-1) (n=11) with concentrations ranging from 15.1 mg L(-1) to 228.6 mg L(-1).
Uemoto, Michihisa; Makino, Masanori; Ota, Yuji; Sakaguchi, Hiromi; Shimizu, Yukari; Sato, Kazuhiro
2018-01-01
Minor and trace metals in aluminum and aluminum alloys have been determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) as an interlaboratory testing toward standardization. The trueness of the measured data was successfully investigated to improve the analytical protocols, using certified reference materials of aluminum. Their precision could also be evaluated, feasible to estimate the uncertainties separately. The accuracy (trueness and precision) of the data were finally in good agreement with the certified values and assigned uncertainties. Repeated measurements of aluminum solutions with different concentrations of the analytes revealed the relative standard deviations of the measurements with concentrations, thus enabling their limits of quantitation. They differed separately and also showed slightly higher values with an aluminum matrix than those without one. In addition, the upper limit of the detectable concentration of silicon with simple acid digestion was estimated to be 0.03 % in the mass fraction.
Modeling for CO poisoning of a fuel cell anode
NASA Technical Reports Server (NTRS)
Dhar, H. P.; Kush, A. K.; Patel, D. N.; Christner, L. G.
1986-01-01
Poisoning losses in a half-cell in the 110-190 C temperature range have been measured in 100 wt pct H3PO4 for various mixtures of H2, CO, and CO2 gases in order to investigate the polarization loss due to poisoning by CO of a porous fuel cell Pt anode. At a fixed current density, the poisoning loss was found to vary linearly with ln of the CO/H2 concentration ratio, although deviations from linearity were noted at lower temperatures and higher current densities for high CO/H2 concentration ratios. The surface coverages of CO were also found to vary linearly with ln of the CO/H2 concentration ratio. A general adsorption relationship is derived. Standard free energies for CO adsorption were found to vary from -14.5 to -12.1 kcal/mol in the 130-190 C temperature range. The standard entropy for CO adsorption was found to be -39 cal/mol per deg K.
Calibrant-Free Analyte Quantitation via a Variable Velocity Flow Cell.
Beck, Jason G; Skuratovsky, Aleksander; Granger, Michael C; Porter, Marc D
2017-01-17
In this paper, we describe a novel method for analyte quantitation that does not rely on calibrants, internal standards, or calibration curves but, rather, leverages the relationship between disparate and predictable surface-directed analyte flux to an array of sensing addresses and a measured resultant signal. To reduce this concept to practice, we fabricated two flow cells such that the mean linear fluid velocity, U, was varied systematically over an array of electrodes positioned along the flow axis. This resulted in a predictable variation of the address-directed flux of a redox analyte, ferrocenedimethanol (FDM). The resultant limiting currents measured at a series of these electrodes, and accurately described by a convective-diffusive transport model, provided a means to calculate an "unknown" concentration without the use of calibrants, internal standards, or a calibration curve. Furthermore, the experiment and concentration calculation only takes minutes to perform. Deviation in calculated FDM concentrations from true values was minimized to less than 0.5% when empirically derived values of U were employed.
[ELEMENTS OF A SYSTEMATIC APPROACH TO HYGIENIC REGULATION OF XENOBIOTICS].
Shtabskiy, B M; Gzhegotskiy, M R; Shafran, L M
2016-01-01
Hygienic standardization (HS) of chemicals remains to be the one of the effective ways to ensure chemical safety of the population. At that hygienic standards (such as maximum allowable concentrations--MACs) are interrelated and aggregated into the coherent systems. Therefore, the task of the study was in establishment of the logic of inter- standard relations between the existing standards and actualization of legitimate relations of the interrelations such as MACwz/MACatm, (i.e., to systematize standards) and so as CL₅₀/MACwz (reflecting the ratio of reliability). In the suggested systemic approach the benchmark indices of the proposed HS system are the values of the MACwz. Standards for other media, including atmosphere air may be only some compartments of MACwz. The performed studies and calculations allowed to justify and implement the system approach into the practice of HS in Ukraine. There is need for further search for additional solutions in nonreachability of LC₅₀ in the experiment, justification of standards for the population in the absence of MACwz, comparison with the data of normative databases of other countries. It is necessary to introduce the value of permissible deviation from the requirements of the systemness, to embody conditions (1)-(7) into the general principle of the prohibition of greater deviation and to harmonize acting and newly introduced standards within frameworks of modern ideology and methods of HS of harmful substances. This opens up broad prospects for the new phase of HS and a significant increase in the reliability of results obtained by the various methods and in different laboratories.
Mills, Jordan P; Tanumihardjo, Sherry A
2006-10-01
Primate lab diets typically contain high vitamin A concentrations when compared with human recommended intakes. In this study, we analyzed the vitamin A contents of liver and serum from 13 adult female African green vervet monkeys (Chlorocebus aethiops). These monkeys were wild-caught and held in captivity for 2 y, during which time they consumed a standard primate diet. Liver vitamin A concentration (mean +/- 1 standard deviation) was 14.6 +/- 2.3 micromol retinol/g liver; subtoxicity in humans is defined as at least 1 micromol/g liver. The serum retinol concentration (0.93 +/- 0.21 microM) was not elevated. Hypertrophy and hyperplasia of hepatic stellate cells were present which, in conjunction with elevated hepatic vitamin A concentrations, are evidence of toxicity. Although the ramifications of chronically toxic vitamin A status in experimental monkeys have not been defined, this state may influence nonhuman primate research outcomes and confound data interpretation. The validity of bone mineral research using nonhuman primates is of greatest concern, in light of the association between vitamin A toxicity and compromised bone health.
Kaynar, Ozgur; Karapinar, Tolga; Hayirli, Armagan; Baydar, Ersoy
2015-12-01
Data on accuracy and precision of the Lactate Scout point-of-care (POC) analyzer in ovine medicine are lacking. The purpose of the study was to assess the reliability of the Lactate Scout in sheep. Fifty-seven sheep at varying ages with various diseases were included. Blood lactate concentration in samples collected from the jugular vein was measured immediately on the Lactate Scout. Plasma L-lactate concentration was measured by the Cobas autoanalyzer as the reference method. Data were subjected to Student's t-test, Passing-Bablok regression, and Bland-Altman plot analyses for comparison and assessment of accuracy, precision, and reliability. Plasma l-lactate concentration was consistently lower than blood L-lactate concentration (3.06 ± 0.24 vs 3.3 ± 0.3 mmol/L, P < .0001). There was a positive correlation between plasma and blood L-lactate concentrations (r = .98, P < .0001). The Lactate Scout had 99% accuracy and 98% precision with the reference method. Blood (Y) and plasma (X) L-lactate concentrations were fitted to Y = 0.28 + 1.00 · X, with a residual standard deviation of 0.31 and a negligible deviation from the identity line (P = .93). The bias was fitted to Y = 0.10 + 0.05 · X, with Sy.x of 0.44 (P < .07). The Lactate Scout has high accuracy and precision, with a negligible bias. It is a reliable POC analyzer to assess L-lactate concentration in ovine medicine. © 2015 American Society for Veterinary Clinical Pathology.
Packing Fraction of a Two-dimensional Eden Model with Random-Sized Particles
NASA Astrophysics Data System (ADS)
Kobayashi, Naoki; Yamazaki, Hiroshi
2018-01-01
We have performed a numerical simulation of a two-dimensional Eden model with random-size particles. In the present model, the particle radii are generated from a Gaussian distribution with mean μ and standard deviation σ. First, we have examined the bulk packing fraction for the Eden cluster and investigated the effects of the standard deviation and the total number of particles NT. We show that the bulk packing fraction depends on the number of particles and the standard deviation. In particular, for the dependence on the standard deviation, we have determined the asymptotic value of the bulk packing fraction in the limit of the dimensionless standard deviation. This value is larger than the packing fraction obtained in a previous study of the Eden model with uniform-size particles. Secondly, we have investigated the packing fraction of the entire Eden cluster including the effect of the interface fluctuation. We find that the entire packing fraction depends on the number of particles while it is independent of the standard deviation, in contrast to the bulk packing fraction. In a similar way to the bulk packing fraction, we have obtained the asymptotic value of the entire packing fraction in the limit NT → ∞. The obtained value of the entire packing fraction is smaller than that of the bulk value. This fact suggests that the interface fluctuation of the Eden cluster influences the packing fraction.
Dehmel, Carola; Braune, Stephan A; Kreymann, Georg; Baehr, Michael; Langebrake, Claudia; Hilgarth, Heike; Nierhaus, Axel; Dartsch, Dorothee C; Kluge, Stefan
2011-08-01
To compare the concentration conformity of infusion solutions manually prepared on intensive care units (ICU) with solutions from pharmacy-based, automated production. A prospective observational study conducted in a university hospital in Germany. Drug concentrations of 100 standardised infusion solutions manually prepared in the ICU and 100 matching solutions from automated production containing amiodarone, noradrenaline or hydrocortisone were measured by high-performance liquid chromatography analysis. Deviations from stated concentrations were calculated, and the quality of achieved concentration conformity of the two production methods was compared. Actual concentrations of 53% of the manually prepared and 16% of the machine-made solutions deviated by >5% above or below the stated concentration. A deviation of >10% was measured in 22% of the manually prepared samples and in 5% of samples from automated production. Of the manually prepared solutions, 15% deviated by >15% above or below the intended concentration. The mean concentration of the manually prepared solutions was 97.2% (SD 12.7%, range 45-129%) and of the machine-made solutions was 101.1% (SD 4.3%, range 90-114%) of the target concentration (p < 0.01). In this preliminary study, ward-based, manually prepared infusion solutions showed clinically relevant deviations in concentration conformity significantly more often than pharmacy-prepared, machine-made solutions. Centralised, automated preparation of standardised infusion solutions may be an effective means to reduce this type of medication error. Further confirmatory studies in larger settings and under conditions of routine automated production are required.
NASA Astrophysics Data System (ADS)
Wen, D. S.; Wen, H.; Shi, Y. G.; Su, B.; Li, Z. C.; Fan, G. Z.
2018-01-01
The B-spline interpolation fitting baseline in electrochemical analysis by differential pulse voltammetry was established for determining the lower concentration 2,6-di-tert-butyl p-cresol(BHT) in Jet Fuel that was less than 5.0 mg/L in the condition of the presence of the 6-tert-butyl-2,4-xylenol.The experimental results has shown that the relative errors are less than 2.22%, the sum of standard deviations less than 0.134mg/L, the correlation coefficient more than 0.9851. If the 2,6-ditert-butyl p-cresol concentration is higher than 5.0mg/L, linear fitting baseline method would be more applicable and simpler.
40 CFR 90.708 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... is 5.0×σ, and is a function of the standard deviation, σ. σ=is the sample standard deviation and is... individual engine. FEL=Family Emission Limit (the standard if no FEL). F=.25×σ. (2) After each test pursuant...
2015-01-01
The goal of this study was to analyse perceptually and acoustically the voices of patients with Unilateral Vocal Fold Paralysis (UVFP) and compare them to the voices of normal subjects. These voices were analysed perceptually with the GRBAS scale and acoustically using the following parameters: mean fundamental frequency (F0), standard-deviation of F0, jitter (ppq5), shimmer (apq11), mean harmonics-to-noise ratio (HNR), mean first (F1) and second (F2) formants frequency, and standard-deviation of F1 and F2 frequencies. Statistically significant differences were found in all of the perceptual parameters. Also the jitter, shimmer, HNR, standard-deviation of F0, and standard-deviation of the frequency of F2 were statistically different between groups, for both genders. In the male data differences were also found in F1 and F2 frequencies values and in the standard-deviation of the frequency of F1. This study allowed the documentation of the alterations resulting from UVFP and addressed the exploration of parameters with limited information for this pathology. PMID:26557690
NASA Astrophysics Data System (ADS)
Krasnenko, N. P.; Kapegesheva, O. F.; Shamanaeva, L. G.
2017-11-01
Spatiotemporal dynamics of the standard deviations of three wind velocity components measured with a mini-sodar in the atmospheric boundary layer is analyzed. During the day on September 16 and at night on September 12 values of the standard deviation changed for the x- and y-components from 0.5 to 4 m/s, and for the z-component from 0.2 to 1.2 m/s. An analysis of the vertical profiles of the standard deviations of three wind velocity components for a 6-day measurement period has shown that the increase of σx and σy with altitude is well described by a power law dependence with exponent changing from 0.22 to 1.3 depending on the time of day, and σz depends linearly on the altitude. The approximation constants have been found and their errors have been estimated. The established physical regularities and the approximation constants allow the spatiotemporal dynamics of the standard deviation of three wind velocity components in the atmospheric boundary layer to be described and can be recommended for application in ABL models.
Altuntepe, Emrah; Emel'yanenko, Vladimir N; Forster-Rotgers, Maximilian; Sadowski, Gabriele; Verevkin, Sergey P; Held, Christoph
2017-10-01
Levulinic acid was esterified with methanol, ethanol, and 1-butanol with the final goal to predict the maximum yield of these equilibrium-limited reactions as function of medium composition. In a first step, standard reaction data (standard Gibbs energy of reaction Δ R g 0 ) were determined from experimental formation properties. Unexpectedly, these Δ R g 0 values strongly deviated from data obtained with classical group contribution methods that are typically used if experimental standard data is not available. In a second step, reaction equilibrium concentrations obtained from esterification catalyzed by Novozym 435 at 323.15 K were measured, and the corresponding activity coefficients of the reacting agents were predicted with perturbed-chain statistical associating fluid theory (PC-SAFT). The so-obtained thermodynamic activities were used to determine Δ R g 0 at 323.15 K. These results could be used to cross-validate Δ R g 0 from experimental formation data. In a third step, reaction-equilibrium experiments showed that equilibrium position of the reactions under consideration depends strongly on the concentration of water and on the ratio of levulinic acid: alcohol in the initial reaction mixtures. The maximum yield of the esters was calculated using Δ R g 0 data from this work and activity coefficients of the reacting agents predicted with PC-SAFT for varying feed composition of the reaction mixtures. The use of the new Δ R g 0 data combined with PC-SAFT allowed good agreement to the measured yields, while predictions based on Δ R g 0 values obtained with group contribution methods showed high deviations to experimental yields.
Jongen, S; Vermeeren, A; van der Sluiszen, N N J J M; Schumacher, M B; Theunissen, E L; Kuypers, K P C; Vuurman, E F P M; Ramaekers, J G
2017-03-01
The on-the-road highway driving test is generally regarded as a gold standard for assessing drug-induced driving impairment. The primary outcome measure is the standard deviation of lateral position (SDLP), a measure of road tracking error or "weaving". The test has been calibrated for incremental doses of alcohol almost 30 years ago in order to define the impact of drug-induced impairment in terms of blood alcohol concentration (BAC) equivalents. Drug-induced changes in SDLP exceeding 2.4 cm have been evaluated as clinically relevant ever since. The present analysis was conducted to assess the robustness of the alcohol effect in a range of on-the-road driving studies which have been conducted since the initial alcohol calibration study. The present study pooled data of 182 participants from nine placebo-controlled crossover studies who performed the highway driving test, while their BAC was at or just below the legal limit for drivers (i.e., 0.5 g/L). Overall, mean SDLP increased with 2.5 cm (95% CI 2.0-2.9 cm). Equivalence testing showed that the clinical relevance criterion value of 2.4 cm fell well within the 95% CI in each individual study. Gender did not affect alcohol-induced changes in SDLP. These results demonstrate the robustness and validity of the clinical relevance criterion for SDLP as measured during on-the-road driving.
The atmospheric lifetime of black carbon
NASA Astrophysics Data System (ADS)
Cape, J. N.; Coyle, M.; Dumitrean, P.
2012-11-01
Black carbon (BC) in the atmosphere contributes to the human health effects of particulate matter and contributes to radiative forcing of climate. The lifetime of BC, particularly the smaller particle sizes (PM2.5) which can be transported over long distances, is therefore an important factor in determining the range of such effects, and the spatial footprint of emission controls. Theory and models suggest that the typical lifetime of BC is around one week. The frequency distributions of measurements of a range of hydrocarbons at a remote rural site in southern Scotland (Auchencorth Moss) between 2007 and 2010 have been used to quantify the relationship between atmospheric lifetime and the geometric standard deviation of observed concentration. The analysis relies on an assumed common major emission source for hydrocarbons and BC, namely diesel-engined vehicles. The logarithm of the standard deviation of the log-transformed concentration data is linearly related to hydrocarbon lifetime, and the same statistic for BC can be used to assess the lifetime of BC relative to the hydrocarbons. Annual average data show BC lifetimes in the range 4-12 days, for an assumed OH concentration of 7 × 105 cm-3. At this site there is little difference in BC lifetime between winter and summer, despite a 3-fold difference in relative hydrocarbon lifetimes. This observation confirms the role of wet deposition as an important removal process for BC, as there is no difference in precipitation between winter and summer at this site. BC lifetime was significantly greater in 2010, which had 23% less rainfall than the preceding 3 years.
A proof for Rhiel's range estimator of the coefficient of variation for skewed distributions.
Rhiel, G Steven
2007-02-01
In this research study is proof that the coefficient of variation (CV(high-low)) calculated from the highest and lowest values in a set of data is applicable to specific skewed distributions with varying means and standard deviations. Earlier Rhiel provided values for d(n), the standardized mean range, and a(n), an adjustment for bias in the range estimator of micro. These values are used in estimating the coefficient of variation from the range for skewed distributions. The d(n) and an values were specified for specific skewed distributions with a fixed mean and standard deviation. In this proof it is shown that the d(n) and an values are applicable for the specific skewed distributions when the mean and standard deviation can take on differing values. This will give the researcher confidence in using this statistic for skewed distributions regardless of the mean and standard deviation.
Jiang, Hua; Yang, Jing; Fan, Li; Li, Fengmin; Huang, Qiliang
2013-01-01
The toxic inert ingredients in pesticide formulations are strictly regulated in many countries. In this paper, a simple and efficient headspace-gas chromatography-mass spectrometry (HSGC-MS) method using fluorobenzene as an internal standard (IS) for rapid simultaneous determination of benzene and toluene in pesticide emulsifiable concentrate (EC) was established. The headspace and GC-MS conditions were investigated and developed. A nonpolar fused silica Rtx-5 capillary column (30 m × 0.20 mm i.d. and 0.25 μm film thickness) with temperature programming was used. Under optimized headspace conditions, equilibration temperature of 120°C, equilibration time of 5 min, and sample size of 50 μL, the regression of the peak area ratios of benzene and toluene to IS on the concentrations of analytes fitted a linear relationship well at the concentration levels ranging from 3.2 g/L to 16.0 g/L. Standard additions of benzene and toluene to blank different matrix solutions 1ead to recoveries of 100.1%–109.5% with a relative standard deviation (RSD) of 0.3%–8.1%. The method presented here stands out as simple and easily applicable, which provides a way for the determination of toxic volatile adjuvant in liquid pesticide formulations. PMID:23607048
Random errors in interferometry with the least-squares method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Qi
2011-01-20
This investigation analyzes random errors in interferometric surface profilers using the least-squares method when random noises are present. Two types of random noise are considered here: intensity noise and position noise. Two formulas have been derived for estimating the standard deviations of the surface height measurements: one is for estimating the standard deviation when only intensity noise is present, and the other is for estimating the standard deviation when only position noise is present. Measurements on simulated noisy interferometric data have been performed, and standard deviations of the simulated measurements have been compared with those theoretically derived. The relationships havemore » also been discussed between random error and the wavelength of the light source and between random error and the amplitude of the interference fringe.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fresquez, Philip R.
Field mice are effective indicators of contaminant presence. This paper reports the concentrations of various radionuclides, heavy metals, polychlorinated biphenyls, high explosives, perchlorate, and dioxin/furans in field mice (mostly deer mice) collected from regional background areas in northern New Mexico. These data, represented as the regional statistical reference level (the mean plus three standard deviations = 99% confidence level), are used to compare with data from field mice collected from areas potentially impacted by Laboratory operations, as per the Environmental Surveillance Program at Los Alamos National Laboratory.
Kurle, Carolyn M; Bakker, Victoria J; Copeland, Holly; Burnett, Joe; Jones Scherbinski, Jennie; Brandt, Joseph; Finkelstein, Myra E
2016-09-06
The critically endangered California condor (Gymnogyps californianus) has relied intermittently on dead-stranded marine mammals since the Pleistocene, and this food source is considered important for their current recovery. However, contemporary marine mammals contain persistent organic pollutants that could threaten condor health. We used stable carbon and nitrogen isotope, contaminant, and behavioral data in coastal versus noncoastal condors to quantify contaminant transfer from marine mammals and created simulation models to predict the risk of reproductive impairment for condors from exposure to DDE (p,p'-DDE), a major metabolite of the chlorinated pesticide DDT. Coastal condors had higher whole blood isotope values and mean concentrations of contaminants associated with marine mammals, including mercury (whole blood), sum chlorinated pesticides (comprised of ∼95% DDE) (plasma), sum polychlorinated biphenyls (PCBs) (plasma), and sum polybrominated diphenyl ethers (PBDEs) (plasma), 12-100-fold greater than those of noncoastal condors. The mean plasma DDE concentration for coastal condors was 500 ± 670 (standard deviation) (n = 22) versus 24 ± 24 (standard deviation) (n = 8) ng/g of wet weight for noncoastal condors, and simulations predicted ∼40% of breeding-age coastal condors have DDE levels associated with eggshell thinning in other avian species. Our analyses demonstrate potentially harmful levels of marine contaminant transfer to California condors, which could hinder the recovery of this terrestrial species.
Maternal Exposure to Bisphenol-A and Fetal Growth Restriction: A Case-Referent Study
Burstyn, Igor; Martin, Jonathan W.; Beesoon, Sanjay; Bamforth, Fiona; Li, Qiaozhi; Yasui, Yutaka; Cherry, Nicola M.
2013-01-01
We conducted a case-referent study of the effect of exposure to bisphenol-A on fetal growth in utero in full-term, live-born singletons in Alberta, Canada. Newborns <10 percentile of expected weight for gestational age and sex were individually matched on sex, maternal smoking and maternal age to referents with weight appropriate to gestational age. Exposure of the fetus to bisphenol-A was estimated from maternal serum collected at 15–16 weeks of gestation. We pooled sera across subjects for exposure assessment, stratified on case-referent status and sex. Individual 1:1 matching was maintained in assembling 69 case and 69 referent pools created from 550 case-referent pairs. Matched pools had an equal number of aliquots from individual women. We used an analytical strategy conditioning on matched set and total pool-level values of covariates to estimate individual-level effects. Pools of cases and referents had identical geometric mean bisphenol-A concentrations (0.5 ng/mL) and similar geometric standard deviations (2.3–2.5). Mean difference in concentration between matched pools was 0 ng/mL, standard deviation: 1 ng/mL. Stratification by sex and control for confounding did not suggest bisphenol-A increased fetal growth restriction. Our analysis does not provide evidence to support the hypothesis that bisphenol-A contributes to fetal growth restriction in full-term singletons. PMID:24336026
Jiang, Ting-Fu; Lv, Zhi-Hua; Wang, Yuan-Hong; Yue, Mei-E
2006-06-01
A new, simple and rapid capillary electrophoresis (CE) method, using hexadimethrine bromide (HDB) as electroosmotic flow (EOF) modifier, was developed for the identification and quantitative determination of four plant hormones, including gibberellin A3 (GA3), indole-3-acetic acid (IAA), alpha-naphthaleneacetic acid (NAA) and 4-chlorophenoxyacetic acid (4-CA). The optimum separation was achieved with 20 mM borate buffer at pH 10.00 containing 0.005% (w/v) of HDB. The applied voltage was -25 kV and the capillary temperature was kept constant at 25 degrees C. Salicylic acid was used as internal standard for quantification. The calibration dependencies exhibited good linearity within the ratios of the concentrations of standard samples and internal standard and the ratios of the peak areas of samples and internal standard. The correlation coefficients were from 0.9952 to 0.9997. The relative standard deviations of migration times and peak areas were < 1.93 and 6.84%, respectively. The effects of buffer pH, the concentration of HDB and the voltage on the resolution were studied systematically. By this method, the contents of plant hormone in biofertilizer were successfully determined within 7 min, with satisfactory repeatability and recovery.
Geochemical fingerprinting and source discrimination in soils at the continental scale
NASA Astrophysics Data System (ADS)
Negrel, Philippe; Sadeghi, Martiya; Ladenberger, Anna; Birke, Manfred; Reimann, Clemens
2014-05-01
Agricultural soil (Ap-horizon, 0-20 cm) samples were collected from a large part of Europe (33 countries, 5.6 million km2) at an average density of 1 sample site per 2500 km2. The resulting 2108 soil samples were air dried, sieved to <2 mm, milled and analysed for their major and trace element concentrations by wavelength dispersive X-ray fluorescence spectrometry (WD-XRF). The main goal of this study is to provide a global view of element mobility and source rocks at the continent scale, either by reference to crustal evolution or normalized patterns of element mobility during weathering processes. The survey area includes several sedimentary basins with different geological history, developed in different climate zones and landscapes and with different land use. In order to normalize the chemical composition of soils, mean values and standard deviation of the selected elements have been checked against values for the upper continental crust (UCC). Some elements turned out to be enriched relative to the UCC (Al, P, Zr, Pb) whereas others, like Mg, Na, Sr and Pb were depleted with regards to the variation represented by the standard deviation. The concept of UCC extended normalization patterns have been further used for the selected elements. The mean value of Rb, K, Y, Ti, Al, Si, Zr, Ce and Fe are very close to the UCC model even if standard deviation suggests slight enrichment or depletion, and Zr shows the best fit with the UCC model using both mean value and standard deviation. Lead and Cr are enriched in European soils when compared to UCC but their standard deviation values show very large variations, particularly towards very low values, which can be interpreted as a lithological effect. Element variability has been explored by looking at the variations using indicator elements. Soil data have been converted into Al-normalized enrichment factors and Na was applied as normalizing element for studying provenance source taking into account the main lithologies of the UCC. This latter normalization highlighted variations related to the soluble and insoluble behavior of some elements (K, Rb versus Ti, Al, Si, V, Y, Zr, Ba, and La, respectively), their reactivity (Fe, Mn, Zn), association with carbonates (Ca and Sr) and with phosphates (P and Ce). The maps of normalized composition revealed some problems with use of classical element ratios due to genetical differences in composition of parent material reflected, for example, in large differences in titanium content in bedrock and soil throughout the Europe.
N2/O2/H2 Dual-Pump Cars: Validation Experiments
NASA Technical Reports Server (NTRS)
OByrne, S.; Danehy, P. M.; Cutler, A. D.
2003-01-01
The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method is used to measure temperature and the relative species densities of N2, O2 and H2 in two experiments. Average values and root-mean-square (RMS) deviations are determined. Mean temperature measurements in a furnace containing air between 300 and 1800 K agreed with thermocouple measurements within 26 K on average, while mean mole fractions agree to within 1.6 % of the expected value. The temperature measurement standard deviation averaged 64 K while the standard deviation of the species mole fractions averaged 7.8% for O2 and 3.8% for N2, based on 200 single-shot measurements. Preliminary measurements have also been performed in a flat-flame burner for fuel-lean and fuel-rich flames. Temperature standard deviations of 77 K were measured, and the ratios of H2 to N2 and O2 to N2 respectively had standard deviations from the mean value of 12.3% and 10% of the measured ratio.
Employing natural reagents from turmeric and lime for acetic acid determination in vinegar sample.
Supharoek, Sam-Ang; Ponhong, Kraingkrai; Siriangkhawut, Watsaka; Grudpan, Kate
2018-04-01
A simple, rapid and environmentally friendly sequential injection analysis system employing natural extract reagents was developed for the determination of acetic acid following an acid-base reaction in the presence of an indicator. Powdered lime and turmeric were utilized as the natural base and indicator, respectively. Mixing lime and turmeric produced an orange to reddish-brown color solution which absorbed the maximum wavelength at 455 nm, with absorbance decreasing with increasing acetic acid concentration. Influential parameters including lime and turmeric concentrations, reagent and sample aspirated volumes, mixing coil length and dispensing flow rate were investigated and optimized. A standard calibration graph was plotted for 0-5.0 mmol/L acetic acid with r 2 = 0.9925. Relative standard deviations (RSD) at 2.0 and 4.0 mmol/L acetic acid were less than 3% (n = 7), with limit of detection (LOD) and limit of quantification (LOQ) at 0.12 and 0.24 mmol/L, respectively. The method was successfully applied to assay acetic acid concentration in cooking vinegar samples. Results achieved were not significantly different from those obtained following a batchwise standard AOAC titration method. Copyright © 2017. Published by Elsevier B.V.
Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.
Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O
2009-04-01
Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.
Schroder, L.J.; Brooks, M.H.; Malo, B.A.; Willoughby, T.C.
1986-01-01
Five intersite comparison studies for the field determination of pH and specific conductance, using simulated-precipitation samples, were conducted by the U.S.G.S. for the National Atmospheric Deposition Program and National Trends Network. These comparisons were performed to estimate the precision of pH and specific conductance determinations made by sampling-site operators. Simulated-precipitation samples were prepared from nitric acid and deionized water. The estimated standard deviation for site-operator determination of pH was 0.25 for pH values ranging from 3.79 to 4.64; the estimated standard deviation for specific conductance was 4.6 microsiemens/cm at 25 C for specific-conductance values ranging from 10.4 to 59.0 microsiemens/cm at 25 C. Performance-audit samples with known analyte concentrations were prepared by the U.S.G.S.and distributed to the National Atmospheric Deposition Program 's Central Analytical Laboratory. The differences between the National Atmospheric Deposition Program and national Trends Network-reported analyte concentrations and known analyte concentrations were calculated, and the bias and precision were determined. For 1983, concentrations of calcium, magnesium, sodium, and chloride were biased at the 99% confidence limit; concentrations of potassium and sulfate were unbiased at the 99% confidence limit. Four analytical laboratories routinely analyzing precipitation were evaluated in their analysis of identical natural- and simulated precipitation samples. Analyte bias for each laboratory was examined using analysis of variance coupled with Duncan 's multiple-range test on data produced by these laboratories, from the analysis of identical simulated-precipitation samples. Analyte precision for each laboratory has been estimated by calculating a pooled variance for each analyte. Interlaboratory comparability results may be used to normalize natural-precipitation chemistry data obtained from two or more of these laboratories. (Author 's abstract)
Shama, S A
2002-11-07
A simple and rapid spectrophotometric methods have been estimated for the microdetermination of phenylephrine HCl (I) and orphenadrine citrate (II). The proposed methods are based on the formation of ion-pair complexes between the examined drugs with alizarine (Aliz), alizarine red S (ARS), alizarine yellow G (AYG) or quinalizarine (Qaliz), which can be measured at the optimum lambda(max). The optimization of the reaction conditions is investigated. Beer's law is obeyed in the concentration ranges 2-36 microgram ml(-1), whereas optimum concentration as adopted from Ringbom plots was 3.5-33 microgram ml(-1). The molar absorptivity, Sandell sensitivity, and detection limit are also calculated. The correlation coefficient was >/=0.9988 (n=6) with a relative standard deviation of =1.7, for six determinations of 20 microgram ml(-1). The proposed methods are successfully applied to the determination of drugs I and II in their dosage forms using the standard addition technique.
Little, M W; O'Connell, N E; Welsh, M D; Mulligan, F J; Ferris, C P
2017-06-01
Because negative energy balance (EB) contributes to transition-period immune dysfunction in dairy cows, dietary management strategies should aim to minimize negative EB during this time. Prepartum diets that oversupply energy may exacerbate negative EB in early lactation, with detrimental effects on immune function. However, with lower body condition score (BCS) cows, it has been shown that offering concentrates in addition to a grass silage-based diet when confined during an 8-wk dry period resulted in increased neutrophil function in early lactation. The aim of this study was to examine if similar benefits occur when concentrate feeding was restricted to a 4-wk period prepartum. Twenty-six multiparous and 22 primiparous Holstein-Friesian cows were offered ad libitum access to medium-quality grass silage until 28 d before their predicted calving dates (actual mean of 32 d prepartum; standard deviation = 6.4). At this time multiparous cows had a mean BCS of 2.9 (standard deviation = 0.12) and primiparous cows a mean BCS of 3.0 (standard deviation = 0.14) on a 1 to 5 scale. Cows were then allocated in a balanced manner to 1 of 2 treatments (13 multiparous cows and 11 primiparous cows on each treatment): silage only (SO) or silage plus concentrates (S+C) until calving. Cows on SO were offered the same grass silage ad libitum. Cows on S+C were offered an ad libitum mixed ration of the same grass silage and additional concentrates in a 60:40 dry matter (DM) ratio, which provided a mean concentrate DM intake (DMI) of 4.5 kg/cow per d. After calving, all cows were offered a common mixed ration (grass silage and concentrates, 40:60 DM ratio) for 70 d postpartum. Offering concentrates in addition to grass silage during the 4 wk prepartum increased prepartum DMI (12.0 versus 10.1 kg/cow per d), EB (+40.0 versus +10.6 MJ/cow per d), and body weight (BW; 640 versus 628 kg), and tended to increase BCS (3.02 versus 2.97). However, postpartum DMI, milk yield, milk composition, BW change, BCS change, serum nonesterified fatty acid, and β-hydroxybutryrate concentrations, health, and corpus luteum measures were unaffected by treatment. The in vitro assays of neutrophil phagocytosis, neutrophil oxidative burst, and interferon gamma production, conducted on blood samples obtained at d 14 prepartum and d 3, 7, 14, and 21 postpartum, were unaffected by treatment. Primiparous cows had higher phagocytic fluorescence intensity at d 14 prepartum and d 3 and 7 postpartum; a higher percentage of neutrophils undergoing oxidative burst at d 3, 7, and 21 postpartum; and a higher oxidative burst fluorescence intensity at d 14 prepartum and d 7, 14, and 21 postpartum compared with multiparous cows. This suggests that neutrophil function of primiparous cows was less sensitive to the changes occurring during the transition period than that of multiparous cows. In conclusion, offering concentrates during the 4-wk period prepartum had no effect on postpartum DMI, milk yield, body tissue mobilization, EB, measures of neutrophil or lymphocyte function, health, or corpus luteum activity. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
An on-line pre-concentration system for determination of cadmium in drinking water using FAAS.
dos Santos, Walter N L; Costa, Jorge L O; Araujo, Rennan G O; de Jesus, Djane S; Costa, Antônio C S
2006-10-11
In the present paper, a minicolumn of polyurethane foam loaded with 4-(2-pyridylazo)-resorcinol (PAR) is proposed as pre-concentration system for cadmium determination in drinking water samples by flame atomic absorption spectrometry. The optimization step was performed using two-level full factorial design and Doehlert matrix, involving the variables: sampling flow rate, elution concentration, buffer concentration and pH. Using the established experimental conditions in the optimization step of: pH 8.2, sampling flow rate 8.5 mL min(-1), buffer concentration 0.05 mol L(-1) and elution concentration of 1.0 mol L(-1), this system allows the determination of cadmium with detection limit (LD) (3sigma/S) of 20.0 ng L(-1) and quantification limit (LQ) (10sigma/S) of 64 ng L(-1), precision expressed as relative standard deviation (R.S.D.) of 5.0 and 4.7% for cadmium concentration of 5.0 and 40.0 microg L(-1), respectively, and a pre-concentration factor of 158 for a sample volume of 20.0 mL. The accuracy was confirmed by cadmium determination in the standard reference material, NIST SRM 1643d trace elements in natural water. This procedure was applied for cadmium determination in drinking water samples collected from Salvador City, Bahia, Brazil. For five samples analyzed, the achieved concentrations varied from 0.31 to 0.86 microg L(-1).
On the Distribution of Protein Refractive Index Increments
Zhao, Huaying; Brown, Patrick H.; Schuck, Peter
2011-01-01
The protein refractive index increment, dn/dc, is an important parameter underlying the concentration determination and the biophysical characterization of proteins and protein complexes in many techniques. In this study, we examine the widely used assumption that most proteins have dn/dc values in a very narrow range, and reappraise the prediction of dn/dc of unmodified proteins based on their amino acid composition. Applying this approach in large scale to the entire set of known and predicted human proteins, we obtain, for the first time, to our knowledge, an estimate of the full distribution of protein dn/dc values. The distribution is close to Gaussian with a mean of 0.190 ml/g (for unmodified proteins at 589 nm) and a standard deviation of 0.003 ml/g. However, small proteins <10 kDa exhibit a larger spread, and almost 3000 proteins have values deviating by more than two standard deviations from the mean. Due to the widespread availability of protein sequences and the potential for outliers, the compositional prediction should be convenient and provide greater accuracy than an average consensus value for all proteins. We discuss how this approach should be particularly valuable for certain protein classes where a high dn/dc is coincidental to structural features, or may be functionally relevant such as in proteins of the eye. PMID:21539801
On the distribution of protein refractive index increments.
Zhao, Huaying; Brown, Patrick H; Schuck, Peter
2011-05-04
The protein refractive index increment, dn/dc, is an important parameter underlying the concentration determination and the biophysical characterization of proteins and protein complexes in many techniques. In this study, we examine the widely used assumption that most proteins have dn/dc values in a very narrow range, and reappraise the prediction of dn/dc of unmodified proteins based on their amino acid composition. Applying this approach in large scale to the entire set of known and predicted human proteins, we obtain, for the first time, to our knowledge, an estimate of the full distribution of protein dn/dc values. The distribution is close to Gaussian with a mean of 0.190 ml/g (for unmodified proteins at 589 nm) and a standard deviation of 0.003 ml/g. However, small proteins <10 kDa exhibit a larger spread, and almost 3000 proteins have values deviating by more than two standard deviations from the mean. Due to the widespread availability of protein sequences and the potential for outliers, the compositional prediction should be convenient and provide greater accuracy than an average consensus value for all proteins. We discuss how this approach should be particularly valuable for certain protein classes where a high dn/dc is coincidental to structural features, or may be functionally relevant such as in proteins of the eye. Copyright © 2011 Biophysical Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruschak, M.L.; Syty, A.
1982-08-01
A technique of nonflame molecular adsorption in the gas phase developed for the determination of sulfite trapped in tetrachloromercurate, is described herein for application to the determination of total sulfur in kerosene. The burner head is removed from the atomic absorption spectrometer and replaced with a flow-through absorption cell. A special reaction vessel is used to evolve SO/sub 2/ from the sulfite in a precise and convenient manner. The transient absorbance caused by the SO/sub 2/, as it is carried through the absorption cell, is measured. Both spiked and unspiked samples of kerosene were analyzed, and the reproducibility of themore » repeated runs is evidenced by a relative standard deviation from the mean of 5% for the unspiked kerosene and 4% for the spiked kerosene. If the detection level is defined as that concentration of S which gives a % S twice the standard deviation from the mean yields, the detection limit for the present method is 0.002% S by weight in kerosene.« less
Detection of pesticides in active and depopulated beehives in Uruguay.
Pareja, Lucía; Colazzo, Marcos; Pérez-Parada, Andrés; Niell, Silvina; Carrasco-Letelier, Leonidas; Besil, Natalia; Cesio, María Verónica; Heinzen, Horacio
2011-10-01
The influence of insecticides commonly used for agricultural purposes on beehive depopulation in Uruguay was investigated. Honeycombs, bees, honey and propolis from depopulated hives were analyzed for pesticide residues, whereas from active beehives only honey and propolis were evaluated. A total of 37 samples were analyzed, representing 14,800 beehives. In depopulated beehives only imidacloprid and fipronil were detected and in active beehives endosulfan, coumaphos, cypermethrin, ethion and chlorpyrifos were found. Coumaphos was present in the highest concentrations, around 1,000 μg/kg, in all the propolis samples from active beehives. Regarding depopulated beehives, the mean levels of imidacloprid found in honeycomb (377 μg/kg, Standard Deviation: 118) and propolis (60 μg/kg, Standard Deviation: 57) are higher than those described to produce bee disorientation and fipronil levels detected in bees (150 and 170 μg/kg) are toxic per se. The other insecticides found can affect the global fitness of the bees causing weakness and a decrease in their overall productivity. These preliminary results suggest that bees exposed to pesticides or its residues can lead them in different ways to the beehive.
Potentiometric sensors for the selective determination of sulbutiamine.
Ahmed, M A; Elbeshlawy, M M
1999-11-01
Five novel polyvinyl chloride (PVC) matrix membrane sensors for the selective determination of sulbutiamine (SBA) cation are described. These sensors are based on molybdate, tetraphenylborate, reineckate, phosphotun gestate and phosphomolybdate, as possible ion-pairing agents. These sensors display rapid near-Nernstian stable response over a relatively wide concentration range 1x10(-2)-1x10(-6) M of sulbutiamine, with calibration slopes 28 32.6 mV decade(-1) over a reasonable pH range 2-6. The proposed sensors proved to have a good selectivity for SBA over some inorganic and organic cations. The five potentiometric sensors were applied successfully in the determination of SBA in a pharmaceutical preparation (arcalion-200) using both direct potentiometry and potentiometric titration. Direct potentiometric determination of microgram quantities of SBA gave average recoveries of 99.4 and 99.3 with mean standard deviation of 0.7 and 0.3 for pure SBA and arcalion-200 formulation respectively. Potentiometric titration of milligram quantities of SBA gave average recoveries of 99.3 and 98.7% with mean standard deviation of 0.7 and 1.2 for pure SBA and arcalion-200 formulation, respectively.
Matrix Summaries Improve Research Reports: Secondary Analyses Using Published Literature
ERIC Educational Resources Information Center
Zientek, Linda Reichwein; Thompson, Bruce
2009-01-01
Correlation matrices and standard deviations are the building blocks of many of the commonly conducted analyses in published research, and AERA and APA reporting standards recommend their inclusion when reporting research results. The authors argue that the inclusion of correlation/covariance matrices, standard deviations, and means can enhance…
Application of snapshot imaging spectrometer in environmental detection
NASA Astrophysics Data System (ADS)
Sun, Kai; Qin, Xiaolei; Zhang, Yu; Wang, Jinqiang
2017-10-01
This study aimed at the application of snapshot imaging spectrometer in environmental detection. The simulated sewage and dyeing wastewater were prepared and the optimal experimental conditions were determined. The white LED array was used as the detection light source and the image of the sample was collected by the imaging spectrometer developed in the laboratory to obtain the spectral information of the sample in the range of 400-800 nm. The standard curve between the absorbance and the concentration of the samples was established. The linear range of a single component of Rhoda mine B was 1-50 mg/L, the linear correlation coefficient was more than 0.99, the recovery was 93%-113% and the relative standard deviations (RSD) was 7.5%. The linear range of chemical oxygen demand (COD) standard solution was 50-900mg/L, the linear correlation coefficient was 0.981, the recovery was 91% -106% and the relative standard deviation (RSD) was 6.7%. The rapid, accurate and precise method for detecting dyes showed an excellent promise for on-site and emergency detection in environment. At the request of the proceedings editor, an updated version of this article was published on 17 October 2017. The original version of this article was replaced due to an accidental inversion of Figure 2 and Figure 3. The Figures have been corrected in the updated and republished version.
The effects of auditory stimulation with music on heart rate variability in healthy women.
Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de
2013-07-01
There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level.
The effects of auditory stimulation with music on heart rate variability in healthy women
Roque, Adriano L.; Valenti, Vitor E.; Guida, Heraldo L.; Campos, Mônica F.; Knap, André; Vanderlei, Luiz Carlos M.; Ferreira, Lucas L.; Ferreira, Celso; de Abreu, Luiz Carlos
2013-01-01
OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of the long-term RR interval indices were reduced during exposure to both music styles in the first group and tended to decrease in the second group whereas the white noise exposure decreased the high frequency index. We observed no changes regarding the triangular interpolation of RR intervals, standard deviation of instantaneous beat-by-beat variability and standard deviation of instantaneous beat-by-beat variability/standard deviation in the long-term RR interval ratio. CONCLUSION: We suggest that relaxant baroque and excitatory heavy metal music slightly decrease global heart rate variability because of the equivalent sound level. PMID:23917660
USL/DBMS NASA/PC R and D project C programming standards
NASA Technical Reports Server (NTRS)
Dominick, Wayne D. (Editor); Moreau, Dennis R.
1984-01-01
A set of programming standards intended to promote reliability, readability, and portability of C programs written for PC research and development projects is established. These standards must be adhered to except where reasons for deviation are clearly identified and approved by the PC team. Any approved deviation from these standards must also be clearly documented in the pertinent source code.
Ran, Yang; Su, Rongtao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Si, Lei
2016-05-10
We present a new quantitative index of standard deviation to measure the homogeneity of spectral lines in a fiber amplifier system so as to find the relation between the stimulated Brillouin scattering (SBS) threshold and the homogeneity of the corresponding spectral lines. A theoretical model is built and a simulation framework has been established to estimate the SBS threshold when input spectra with different homogeneities are set. In our experiment, by setting the phase modulation voltage to a constant value and the modulation frequency to different values, spectral lines with different homogeneities can be obtained. The experimental results show that the SBS threshold increases negatively with the standard deviation of the modulated spectrum, which is in good agreement with the theoretical results. When the phase modulation voltage is confined to 10 V and the modulation frequency is set to 80 MHz, the standard deviation of the modulated spectrum equals 0.0051, which is the lowest value in our experiment. Thus, at this time, the highest SBS threshold has been achieved. This standard deviation can be a good quantitative index in evaluating the power scaling potential in a fiber amplifier system, which is also a design guideline in suppressing the SBS to a better degree.
Yang, Gai-Xiu; Sun, Yong-Ming; Kong, Xiao-Ying; Zhen, Feng; Li, Ying; Li, Lian-Hua; Lei, Ting-Zhou; Yuan, Zhen-Hong; Chen, Guan-Yi
2013-01-01
Microbial fuel cells (MFCs) are devices that exploit microorganisms as biocatalysts to degrade organic matter or sludge present in wastewater (WW), and thereby generate electricity. We developed a simple, low-cost single-chamber microbial fuel cell (SCMFC)-type biochemical oxygen demand (BOD) sensor using carbon felt (anode) and activated sludge, and demonstrated its feasibility in the construction of a real-time BOD measurement system. Further, the effects of anodic pH and organic concentration on SCMFC performance were examined, and the correlation between BOD concentration and its response time was analyzed. Our results demonstrated that the SCMFC exhibited a stable voltage after 132 min following the addition of synthetic WW (BOD concentration: 200 mg/L). Notably, the response signal increased with an increase in BOD concentration (range: 5-200 mg/L) and was found to be directly proportional to the substrate concentration. However, at higher BOD concentrations (>120 mg/L) the response signal remained unaltered. Furthermore, we optimized the SCMFC using synthetic WW, and tested it with real WW. Upon feeding real WW, the BOD values exhibited a standard deviation from 2.08 to 8.3% when compared to the standard BOD5 method, thus demonstrating the practical applicability of the developed system to real treatment effluents.
Peptide concentration alters intermediate species in amyloid β fibrillation kinetics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garvey, M., E-mail: megan.garvey@molbiotech.rwth-aachen.de; Morgado, I., E-mail: immorgado@ualg.pt
2013-04-12
Highlights: ► Aβ(1–40) aggregation in vitro has been monitored at different concentrations. ► Aβ(1–40) fibrillation does not always follow conventional kinetic mechanisms. ► We demonstrate non-linear features in the kinetics of Aβ(1–40) fibril formation. ► At high Aβ(1–40) concentrations secondary processes dictate fibrillation speed. ► Intermediate species may play significant roles on final amyloid fibril development. -- Abstract: The kinetic mechanism of amyloid aggregation remains to be fully understood. Investigations into the species present in the different kinetic phases can assist our comprehension of amyloid diseases and further our understanding of the mechanism behind amyloid β (Aβ) (1–40) peptide aggregation.more » Thioflavin T (ThT) fluorescence and transmission electron microscopy (TEM) have been used in combination to monitor Aβ(1–40) aggregation in vitro at both normal and higher than standard concentrations. The observed fibrillation behaviour deviates, in several respects, from standard concepts of the nucleation–polymerisation models and shows such features as concentration-dependent non-linear effects in the assembly mechanism. Aβ(1–40) fibrillation kinetics do not always follow conventional kinetic mechanisms and, specifically at high concentrations, intermediate structures become populated and secondary processes may further modify the fibrillation mechanism.« less
Production of NO2 from Photolysis of Peroxyacetyl Nitrate
NASA Technical Reports Server (NTRS)
Mazely, Troy L.; Friedl, Randall R.; Sander, Stanley P.
1965-01-01
Peroxyacetyl nitrate (PAN) vapor was photolyzed at 248 nm, and the NO2 photoproduct was detected by laser-induced fluorescence. The quantum yield for the production of NO2 from PAN photolysis was determined by comparison to HNO3 photolysis data taken under identical experimental conditions. The average of data collected over a range of total pressures, precursor concentrations, and buffer gases was 0.83 +/- 0.09 for the NO2 quantum yield, where the statistical uncertainty is 2 standard deviations.
Local fluctuations of ozone from 16 km to 45 km deduced from in situ vertical ozone profile
NASA Technical Reports Server (NTRS)
Moreau, G.; Robert, C.
1994-01-01
A vertical ozone profile obtained by an in situ ozone sonde from 16 km to 45 km, has allowed to observe local ozone concentration variations. These variations can be observed, thanks to a fast measurement system based on a UV absorption KrF excimer laser beam in a multipass cell. Ozone standard deviation versus altitude calculated from the mean is derived. Ozone variations or fluctuations are correlated with the different dynamic zones of the stratosphere.
Trace Chemical Analysis Methodology
1980-04-01
oxidation of nitrite-containing species. Calibration studies were then made in preparation for the analysis of unknown samples of nitrate in urine and...the procedure for nitrate determination was made on two types of samples : human urine , and drinking water from a city water supply. Five samples of...AND URINE Concentration Standard Sample type of NO3, ppm deviation Drinking water 1.29 ±0 04 1.20 ±0.09 1.29 ±0.14 1.15 ±0.08 0.88 ±0.07 Human urine
Pope, Larry M.; Diaz, A.M.
1982-01-01
Quality-of-water data, collected October 21-23, 1980, and a statistical summary are presented for 42 coal-mined strip pits in Crawford and Cherokee Counties, Southeastern Kansas. The statistical summary includes minimum and maximum observed values , mean, and standard deviation. Simple linear regression equations relating specific conductance, dissolved solids, and acidity to concentrations of dissolved solids, sulfate, calcium, and magnesium, potassium, aluminum, and iron are also presented. (USGS)
NetCDF file of the SREF standard deviation of wind speed and direction that was used to inject variability in the FDDA input.variable U_NDG_OLD contains standard deviation of wind speed (m/s)variable V_NDG_OLD contains the standard deviation of wind direction (deg)This dataset is associated with the following publication:Gilliam , R., C. Hogrefe , J. Godowitch, S. Napelenok , R. Mathur , and S.T. Rao. Impact of inherent meteorology uncertainty on air quality model predictions. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 120(23): 12,259–12,280, (2015).
Oates, R P; Mcmanus, Michelle; Subbiah, Seenivasan; Klein, David M; Kobelski, Robert
2017-07-14
Internal standards are essential in electrospray ionization liquid chromatography-mass spectrometry (ESI-LC-MS) to correct for systematic error associated with ionization suppression and/or enhancement. A wide array of instrument setups and interfaces has created difficulty in comparing the quantitation of absolute analyte response across laboratories. This communication demonstrates the use of primary standards as operational qualification standards for LC-MS instruments and their comparison with commonly accepted internal standards. In monitoring the performance of internal standards for perfluorinated compounds, potassium hydrogen phthalate (KHP) presented lower inter-day variability in instrument response than a commonly accepted deuterated perfluorinated internal standard (d3-PFOS), with percent relative standard deviations less than or equal to 6%. The inter-day precision of KHP was greater than d3-PFOS over a 28-day monitoring of perfluorooctanesulfonic acid (PFOS), across concentrations ranging from 0 to 100μg/L. The primary standard trometamol (Trizma) performed as well as known internal standards simeton and tris (2-chloroisopropyl) phosphate (TCPP), with intra-day precision of Trizma response as low as 7% RSD on day 28. The inter-day precision of Trizma response was found to be greater than simeton and TCPP, across concentrations of neonicotinoids ranging from 1 to 100μg/L. This study explores the potential of primary standards to be incorporated into LC-MS/MS methodology to improve the quantitative accuracy in environmental contaminant analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
75 FR 67093 - Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-01
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0517] Iceberg Water Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... from the requirements of the standards of identity issued under section 401 of the Federal Food, Drug...
78 FR 2273 - Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-10
... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-P-1189] Canned Tuna Deviating From Identity Standard; Temporary Permit for Market Testing AGENCY: Food and Drug... interstate shipment of experimental packs of food varying from the requirements of standards of identity...
Upgraded FAA Airfield Capacity Model. Volume 2. Technical Description of Revisions
1981-02-01
the threshold t k a the time at which departure k is released FIGURE 3-1 TIME AXIS DIAGRAM OF SINGLE RUNWAY OPERATIONS 3-2 J"- SIGMAR the standard...standard deviation of the interarrival time. SIGMAR - the standard deviation of the arrival runway occupancy time. A-5 SINGLE - program subroutine for
Fernandes, S M; Lima, J L; Rangel, A O
2000-01-01
A flow injection system for the automatic determination of total phosphorus in beer is described. The developed manifold uses a two-stage photooxidation/thermal digestion procedure together with oxidizing and hydrolyzing reagents to convert all forms of phosphorus compounds to orthophosphate. Polyphosphates are hydrolyzed by acid and heat, and organo-phosphates are digested by UV-catalyzed peroxodisulfate oxidation. The orthophosphate formed is then spectrophotometrically determined by the phosphomolybdenum blue reaction, using stannous chloride as reducing agent. The results obtained for a set of 19 beer samples (with concentrations from 120 to 735 mg P/L) were in good agreement with the reference method, the maximum relative deviation found being 4.7%. Relative standard deviations for ten consecutive determinations were lower than 1.5%, and a detection limit of 1 mg P/L was achieved.
Methods of editing cloud and atmospheric layer affected pixels from satellite data
NASA Technical Reports Server (NTRS)
Nixon, P. R.; Wiegand, C. L.; Richardson, A. J.; Johnson, M. P. (Principal Investigator)
1982-01-01
Subvisible cirrus clouds (SCi) were easily distinguished in mid-infrared (MIR) TIROS-N daytime data from south Texas and northeast Mexico. The MIR (3.55-3.93 micrometer) pixel digital count means of the SCi affected areas were more than 3.5 standard deviations on the cold side of the scene means. (These standard deviations were made free of the effects of unusual instrument error by factoring out the Ch 3 MIR noise on the basis of detailed examination of noisy and noise-free pixels). SCi affected areas in the IR Ch 4 (10.5-11.5 micrometer) appeared cooler than the general scene, but were not as prominent as in Ch 3, being less than 2 standard deviations from the scene mean. Ch 3 and 4 standard deviations and coefficients of variation are not reliable indicators, by themselves, of the presence of SCi because land features can have similar statistical properties.
A Taxonomy of Delivery and Documentation Deviations During Delivery of High-Fidelity Simulations.
McIvor, William R; Banerjee, Arna; Boulet, John R; Bekhuis, Tanja; Tseytlin, Eugene; Torsher, Laurence; DeMaria, Samuel; Rask, John P; Shotwell, Matthew S; Burden, Amanda; Cooper, Jeffrey B; Gaba, David M; Levine, Adam; Park, Christine; Sinz, Elizabeth; Steadman, Randolph H; Weinger, Matthew B
2017-02-01
We developed a taxonomy of simulation delivery and documentation deviations noted during a multicenter, high-fidelity simulation trial that was conducted to assess practicing physicians' performance. Eight simulation centers sought to implement standardized scenarios over 2 years. Rules, guidelines, and detailed scenario scripts were established to facilitate reproducible scenario delivery; however, pilot trials revealed deviations from those rubrics. A taxonomy with hierarchically arranged terms that define a lack of standardization of simulation scenario delivery was then created to aid educators and researchers in assessing and describing their ability to reproducibly conduct simulations. Thirty-six types of delivery or documentation deviations were identified from the scenario scripts and study rules. Using a Delphi technique and open card sorting, simulation experts formulated a taxonomy of high-fidelity simulation execution and documentation deviations. The taxonomy was iteratively refined and then tested by 2 investigators not involved with its development. The taxonomy has 2 main classes, simulation center deviation and participant deviation, which are further subdivided into as many as 6 subclasses. Inter-rater classification agreement using the taxonomy was 74% or greater for each of the 7 levels of its hierarchy. Cohen kappa calculations confirmed substantial agreement beyond that expected by chance. All deviations were classified within the taxonomy. This is a useful taxonomy that standardizes terms for simulation delivery and documentation deviations, facilitates quality assurance in scenario delivery, and enables quantification of the impact of deviations upon simulation-based performance assessment.
Kwon, Deukwoo; Reis, Isildinha M
2015-08-12
When conducting a meta-analysis of a continuous outcome, estimated means and standard deviations from the selected studies are required in order to obtain an overall estimate of the mean effect and its confidence interval. If these quantities are not directly reported in the publications, they must be estimated from other reported summary statistics, such as the median, the minimum, the maximum, and quartiles. We propose a simulation-based estimation approach using the Approximate Bayesian Computation (ABC) technique for estimating mean and standard deviation based on various sets of summary statistics found in published studies. We conduct a simulation study to compare the proposed ABC method with the existing methods of Hozo et al. (2005), Bland (2015), and Wan et al. (2014). In the estimation of the standard deviation, our ABC method performs better than the other methods when data are generated from skewed or heavy-tailed distributions. The corresponding average relative error (ARE) approaches zero as sample size increases. In data generated from the normal distribution, our ABC performs well. However, the Wan et al. method is best for estimating standard deviation under normal distribution. In the estimation of the mean, our ABC method is best regardless of assumed distribution. ABC is a flexible method for estimating the study-specific mean and standard deviation for meta-analysis, especially with underlying skewed or heavy-tailed distributions. The ABC method can be applied using other reported summary statistics such as the posterior mean and 95 % credible interval when Bayesian analysis has been employed.
On Teaching about the Coefficient of Variation in Introductory Statistics Courses
ERIC Educational Resources Information Center
Trafimow, David
2014-01-01
The standard deviation is related to the mean by virtue of the coefficient of variation. Teachers of statistics courses can make use of that fact to make the standard deviation more comprehensible for statistics students.
Yeh, Chia-Hsien; Zhao, Zi-Qi; Shen, Pi-Lan; Lin, Yu-Cheng
2014-01-01
This study presents an optical inspection system for detecting a commercial point-of-care testing product and a new detection model covering from qualitative to quantitative analysis. Human chorionic gonadotropin (hCG) strips (cut-off value of the hCG commercial product is 25 mIU/mL) were the detection target in our study. We used a complementary metal-oxide semiconductor (CMOS) sensor to detect the colors of the test line and control line in the specific strips and to reduce the observation errors by the naked eye. To achieve better linearity between the grayscale and the concentration, and to decrease the standard deviation (increase the signal to noise ratio, S/N), the Taguchi method was used to find the optimal parameters for the optical inspection system. The pregnancy test used the principles of the lateral flow immunoassay, and the colors of the test and control line were caused by the gold nanoparticles. Because of the sandwich immunoassay model, the color of the gold nanoparticles in the test line was darkened by increasing the hCG concentration. As the results reveal, the S/N increased from 43.48 dB to 53.38 dB, and the hCG concentration detection increased from 6.25 to 50 mIU/mL with a standard deviation of less than 10%. With the optimal parameters to decrease the detection limit and to increase the linearity determined by the Taguchi method, the optical inspection system can be applied to various commercial rapid tests for the detection of ketamine, troponin I, and fatty acid binding protein (FABP). PMID:25256108
Process analytical technology in continuous manufacturing of a commercial pharmaceutical product.
Vargas, Jenny M; Nielsen, Sarah; Cárdenas, Vanessa; Gonzalez, Anthony; Aymat, Efrain Y; Almodovar, Elvin; Classe, Gustavo; Colón, Yleana; Sanchez, Eric; Romañach, Rodolfo J
2018-03-01
The implementation of process analytical technology and continuous manufacturing at an FDA approved commercial manufacturing site is described. In this direct compaction process the blends produced were monitored with a Near Infrared (NIR) spectroscopic calibration model developed with partial least squares (PLS) regression. The authors understand that this is the first study where the continuous manufacturing (CM) equipment was used as a gravimetric reference method for the calibration model. A principal component analysis (PCA) model was also developed to identify the powder blend, and determine whether it was similar to the calibration blends. An air diagnostic test was developed to assure that powder was present within the interface when the NIR spectra were obtained. The air diagnostic test as well the PCA and PLS calibration model were integrated into an industrial software platform that collects the real time NIR spectra and applies the calibration models. The PCA test successfully detected an equipment malfunction. Variographic analysis was also performed to estimate the sampling analytical errors that affect the results from the NIR spectroscopic method during commercial production. The system was used to monitor and control a 28 h continuous manufacturing run, where the average drug concentration determined by the NIR method was 101.17% of label claim with a standard deviation of 2.17%, based on 12,633 spectra collected. The average drug concentration for the tablets produced from these blends was 100.86% of label claim with a standard deviation of 0.4%, for 500 tablets analyzed by Fourier Transform Near Infrared (FT-NIR) transmission spectroscopy. The excellent agreement between the mean drug concentration values in the blends and tablets produced provides further evidence of the suitability of the validation strategy that was followed. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Edwards, L. L.; Harvey, T. F.; Freis, R. P.; Pitovranov, S. E.; Chernokozhin, E. V.
1992-10-01
The accuracy associated with assessing the environmental consequences of an accidental release of radioactivity is highly dependent on our knowledge of the source term characteristics and, in the case when the radioactivity is condensed on particles, the particle size distribution, all of which are generally poorly known. This paper reports on the development of a numerical technique that integrates the radiological measurements with atmospheric dispersion modeling. This results in a more accurate particle-size distribution and particle injection height estimation when compared with measurements of high explosive dispersal of (239)Pu. The estimation model is based on a non-linear least squares regression scheme coupled with the ARAC three-dimensional atmospheric dispersion models. The viability of the approach is evaluated by estimation of ADPIC model input parameters such as the ADPIC particle size mean aerodynamic diameter, the geometric standard deviation, and largest size. Additionally we estimate an optimal 'coupling coefficient' between the particles and an explosive cloud rise model. The experimental data are taken from the Clean Slate 1 field experiment conducted during 1963 at the Tonopah Test Range in Nevada. The regression technique optimizes the agreement between the measured and model predicted concentrations of (239)Pu by varying the model input parameters within their respective ranges of uncertainties. The technique generally estimated the measured concentrations within a factor of 1.5, with the worst estimate being within a factor of 5, very good in view of the complexity of the concentration measurements, the uncertainties associated with the meteorological data, and the limitations of the models. The best fit also suggest a smaller mean diameter and a smaller geometric standard deviation on the particle size as well as a slightly weaker particle to cloud coupling than previously reported.
Equine alpha-fetoprotein levels in Lipizzaner mares with normal pregnancies and with pregnancy loss.
Vincze, Boglárka; Gáspárdy, András; Kulcsár, Margit; Baska, Ferenc; Bálint, Ádám; Hegedűs, György Tamás; Szenci, Ottó
2015-12-01
Alpha-fetoprotein has proved to be a good indicator of fetal well-being in human medicine for decades. Although this molecule is present in most of the mammalian species including horses, reference values in healthy and high-risk pregnant mares have not yet been published. The aim of the present study was to determine whether equine alpha-fetoprotein (eqAFP) is a good indicator of complicated pregnancies in Lipizzaner mares. A total of 111 serum samples from 30 mares have been analyzed for eqAFP levels throughout gestation (Days 60-325). After the pregnancy was confirmed, 23 mares had normal pregnancies with viable foals, six had late embryonic loss, and one of the mares aborted in the ninth gestational month. Equine alpha-fetoprotein concentrations significantly differed in the normal group (72.93 ± 49.25 pg/mL; mean ± standard deviation) and in the complicated pregnancy loss group (152 ± 36.48 pg/mL; mean ± standard deviation). The mares' age, gestational age, and the conception rate significantly affected the alpha-fetoprotein concentrations in the normal group. Furthermore, notable individual differences occurred in eqAFP concentrations between mares. Equine alpha-fetoprotein seems to be an important indicator of fetal well-being in horses, but there are still some unanswered questions (levels in foals of different age, ponies, and draft horses) regarding this serum protein. Large-scale studies are needed to assess the specificity, sensitivity, and reliability of this test as a possible future diagnostic tool for fetal well-being in horses. Copyright © 2015 Elsevier Inc. All rights reserved.
On the variability of the Priestley-Taylor coefficient over water bodies
NASA Astrophysics Data System (ADS)
Assouline, Shmuel; Li, Dan; Tyler, Scott; Tanny, Josef; Cohen, Shabtai; Bou-Zeid, Elie; Parlange, Marc; Katul, Gabriel G.
2016-01-01
Deviations in the Priestley-Taylor (PT) coefficient αPT from its accepted 1.26 value are analyzed over large lakes, reservoirs, and wetlands where stomatal or soil controls are minimal or absent. The data sets feature wide variations in water body sizes and climatic conditions. Neither surface temperature nor sensible heat flux variations alone, which proved successful in characterizing αPT variations over some crops, explain measured deviations in αPT over water. It is shown that the relative transport efficiency of turbulent heat and water vapor is key to explaining variations in αPT over water surfaces, thereby offering a new perspective over the concept of minimal advection or entrainment introduced by PT. Methods that allow the determination of αPT based on low-frequency sampling (i.e., 0.1 Hz) are then developed and tested, which are usable with standard meteorological sensors that filter some but not all turbulent fluctuations. Using approximations to the Gram determinant inequality, the relative transport efficiency is derived as a function of the correlation coefficient between temperature and water vapor concentration fluctuations (RTq). The proposed approach reasonably explains the measured deviations from the conventional αPT = 1.26 value even when RTq is determined from air temperature and water vapor concentration time series that are Gaussian-filtered and subsampled to a cutoff frequency of 0.1 Hz. Because over water bodies, RTq deviations from unity are often associated with advection and/or entrainment, linkages between αPT and RTq offer both a diagnostic approach to assess their significance and a prognostic approach to correct the 1.26 value when using routine meteorological measurements of temperature and humidity.
NASA Technical Reports Server (NTRS)
Campbell, J. W.
1973-01-01
A stochasitc model of the atmosphere between 30 and 90 km was developed for use in Monte Carlo space shuttle entry studies. The model is actually a family of models, one for each latitude-season category as defined in the 1966 U.S. Standard Atmosphere Supplements. Each latitude-season model generates a pseudo-random temperature profile whose mean is the appropriate temperature profile from the Standard Atmosphere Supplements. The standard deviation of temperature at each altitude for a given latitude-season model was estimated from sounding-rocket data. Departures from the mean temperature at each altitude were produced by assuming a linear regression of temperature on the solar heating rate of ozone. A profile of random ozone concentrations was first generated using an auxiliary stochastic ozone model, also developed as part of this study, and then solar heating rates were computed for the random ozone concentrations.
NASA Technical Reports Server (NTRS)
McFerrin, Michael; Snell, Edward; Curreri, Peter A. (Technical Monitor)
2002-01-01
An X-ray based method for determining cryoprotectant concentrations necessary to protect solutions from crystalline ice formation was developed. X-ray images from a CCD area detector were integrated as powder patterns and quantified by determining the standard deviation of the slope of the normalized intensity curve in the resolution range where ice rings are known to occur. The method was tested determining the concentrations of glycerol, PEG400, ethylene glycol and 1,2-propanediol necessary to form an amorphous glass at 1OOK with each of the 98 crystallization solutions of Crystal Screens I and II (Hampton Research, Laguna Hills, California, USA). For conditions that required glycerol concentrations of 35% or above cryoprotectant conditions using 2,3-butanediol were determined. The method proved to be remarkably accurate. The results build on the work of [Garman and Mitchell] and extend the number, of suitable starting conditions to alternative cryoprotectants. In particular, 1,2-propanediol has emerged as a particularly good additive for glass formation upon flash cooling.
Method development estimating ambient mercury concentration from monitored mercury wet deposition
NASA Astrophysics Data System (ADS)
Chen, S. M.; Qiu, X.; Zhang, L.; Yang, F.; Blanchard, P.
2013-05-01
Speciated atmospheric mercury data have recently been monitored at multiple locations in North America; but the spatial coverage is far less than the long-established mercury wet deposition network. The present study describes a first attempt linking ambient concentration with wet deposition using Beta distribution fitting of a ratio estimate. The mean, median, mode, standard deviation, and skewness of the fitted Beta distribution parameters were generated using data collected in 2009 at 11 monitoring stations. Comparing the normalized histogram and the fitted density function, the empirical and fitted Beta distribution of the ratio shows a close fit. The estimated ambient mercury concentration was further partitioned into reactive gaseous mercury and particulate bound mercury using linear regression model developed by Amos et al. (2012). The method presented here can be used to roughly estimate mercury ambient concentration at locations and/or times where such measurement is not available but where wet deposition is monitored.
Babb, James; Xia, Ding; Chang, Gregory; Krasnokutsky, Svetlana; Abramson, Steven B.; Jerschow, Alexej; Regatte, Ravinder R.
2013-01-01
Purpose: To assess the potential use of sodium magnetic resonance (MR) imaging of cartilage, with and without fluid suppression by using an adiabatic pulse, for classifying subjects with versus subjects without osteoarthritis at 7.0 T. Materials and Methods: The study was approved by the institutional review board and was compliant with HIPAA. The knee cartilage of 19 asymptomatic (control subjects) and 28 symptomatic (osteoarthritis patients) subjects underwent 7.0-T sodium MR imaging with use of two different sequences: one without fluid suppression (radial three-dimensional sequence) and one with fluid suppression (inversion recovery [IR] wideband uniform rate and smooth truncation [WURST]). Fluid suppression was obtained by using IR with an adiabatic inversion pulse (WURST pulse). Mean sodium concentrations and their standard deviations were measured in the patellar, femorotibial medial, and lateral cartilage regions over four consecutive sections for each subject. The minimum, maximum, median, and average means and standard deviations were calculated over all measurements for each subject. The utility of these measures in the detection of osteoarthritis was evaluated by using logistic regression and the area under the receiver operating characteristic curve (AUC). Bonferroni correction was applied to the P values obtained with logistic regression. Results: Measurements from IR WURST were found to be significant predicators of all osteoarthritis (Kellgren-Lawrence score of 1–4) and early osteoarthritis (Kellgren-Lawrence score of 1 or 2). The minimum standard deviation provided the highest AUC (0.83) with the highest accuracy (>78%), sensitivity (>82%), and specificity (>74%) for both all osteoarthritis and early osteoarthritis groups. Conclusion: Quantitative sodium MR imaging at 7.0 T with fluid suppression by using adiabatic IR is a potential biomarker for osteoarthritis. © RSNA, 2013 PMID:23468572
Cramer, Richard D.
2015-01-01
The possible applicability of the new template CoMFA methodology to the prediction of unknown biological affinities was explored. For twelve selected targets, all ChEMBL binding affinities were used as training and/or prediction sets, making these 3D-QSAR models the most structurally diverse and among the largest ever. For six of the targets, X-ray crystallographic structures provided the aligned templates required as input (BACE, cdk1, chk2, carbonic anhydrase-II, factor Xa, PTP1B). For all targets including the other six (hERG, cyp3A4 binding, endocrine receptor, COX2, D2, and GABAa), six modeling protocols applied to only three familiar ligands provided six alternate sets of aligned templates. The statistical qualities of the six or seven models thus resulting for each individual target were remarkably similar. Also, perhaps unexpectedly, the standard deviations of the errors of cross-validation predictions accompanying model derivations were indistinguishable from the standard deviations of the errors of truly prospective predictions. These standard deviations of prediction ranged from 0.70 to 1.14 log units and averaged 0.89 (8x in concentration units) over the twelve targets, representing an average reduction of almost 50% in uncertainty, compared to the null hypothesis of “predicting” an unknown affinity to be the average of known affinities. These errors of prediction are similar to those from Tanimoto coefficients of fragment occurrence frequencies, the predominant approach to side effect prediction, which template CoMFA can augment by identifying additional active structural classes, by improving Tanimoto-only predictions, by yielding quantitative predictions of potency, and by providing interpretable guidance for avoiding or enhancing any specific target response. PMID:26065424
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Morikawa, Kei; Kurimoto, Noriaki; Inoue, Takeo; Mineshita, Masamichi; Miyazawa, Teruomi
2015-01-01
Endobronchial ultrasonography using a guide sheath (EBUS-GS) is an increasingly common bronchoscopic technique, but currently, no methods have been established to quantitatively evaluate EBUS images of peripheral pulmonary lesions. The purpose of this study was to evaluate whether histogram data collected from EBUS-GS images can contribute to the diagnosis of lung cancer. Histogram-based analyses focusing on the brightness of EBUS images were retrospectively conducted: 60 patients (38 lung cancer; 22 inflammatory diseases), with clear EBUS images were included. For each patient, a 400-pixel region of interest was selected, typically located at a 3- to 5-mm radius from the probe, from recorded EBUS images during bronchoscopy. Histogram height, width, height/width ratio, standard deviation, kurtosis and skewness were investigated as diagnostic indicators. Median histogram height, width, height/width ratio and standard deviation were significantly different between lung cancer and benign lesions (all p < 0.01). With a cutoff value for standard deviation of 10.5, lung cancer could be diagnosed with an accuracy of 81.7%. Other characteristics investigated were inferior when compared to histogram standard deviation. Histogram standard deviation appears to be the most useful characteristic for diagnosing lung cancer using EBUS images. © 2015 S. Karger AG, Basel.
Role of the standard deviation in the estimation of benchmark doses with continuous data.
Gaylor, David W; Slikker, William
2004-12-01
For continuous data, risk is defined here as the proportion of animals with values above a large percentile, e.g., the 99th percentile or below the 1st percentile, for the distribution of values among control animals. It is known that reducing the standard deviation of measurements through improved experimental techniques will result in less stringent (higher) doses for the lower confidence limit on the benchmark dose that is estimated to produce a specified risk of animals with abnormal levels for a biological effect. Thus, a somewhat larger (less stringent) lower confidence limit is obtained that may be used as a point of departure for low-dose risk assessment. It is shown in this article that it is important for the benchmark dose to be based primarily on the standard deviation among animals, s(a), apart from the standard deviation of measurement errors, s(m), within animals. If the benchmark dose is incorrectly based on the overall standard deviation among average values for animals, which includes measurement error variation, the benchmark dose will be overestimated and the risk will be underestimated. The bias increases as s(m) increases relative to s(a). The bias is relatively small if s(m) is less than one-third of s(a), a condition achieved in most experimental designs.
Statistical models for estimating daily streamflow in Michigan
Holtschlag, D.J.; Salehi, Habib
1992-01-01
Statistical models for estimating daily streamflow were analyzed for 25 pairs of streamflow-gaging stations in Michigan. Stations were paired by randomly choosing a station operated in 1989 at which 10 or more years of continuous flow data had been collected and at which flow is virtually unregulated; a nearby station was chosen where flow characteristics are similar. Streamflow data from the 25 randomly selected stations were used as the response variables; streamflow data at the nearby stations were used to generate a set of explanatory variables. Ordinary-least squares regression (OLSR) equations, autoregressive integrated moving-average (ARIMA) equations, and transfer function-noise (TFN) equations were developed to estimate the log transform of flow for the 25 randomly selected stations. The precision of each type of equation was evaluated on the basis of the standard deviation of the estimation errors. OLSR equations produce one set of estimation errors; ARIMA and TFN models each produce l sets of estimation errors corresponding to the forecast lead. The lead-l forecast is the estimate of flow l days ahead of the most recent streamflow used as a response variable in the estimation. In this analysis, the standard deviation of lead l ARIMA and TFN forecast errors were generally lower than the standard deviation of OLSR errors for l < 2 days and l < 9 days, respectively. Composite estimates were computed as a weighted average of forecasts based on TFN equations and backcasts (forecasts of the reverse-ordered series) based on ARIMA equations. The standard deviation of composite errors varied throughout the length of the estimation interval and generally was at maximum near the center of the interval. For comparison with OLSR errors, the mean standard deviation of composite errors were computed for intervals of length 1 to 40 days. The mean standard deviation of length-l composite errors were generally less than the standard deviation of the OLSR errors for l < 32 days. In addition, the composite estimates ensure a gradual transition between periods of estimated and measured flows. Model performance among stations of differing model error magnitudes were compared by computing ratios of the mean standard deviation of the length l composite errors to the standard deviation of OLSR errors. The mean error ratio for the set of 25 selected stations was less than 1 for intervals l < 32 days. Considering the frequency characteristics of the length of intervals of estimated record in Michigan, the effective mean error ratio for intervals < 30 days was 0.52. Thus, for intervals of estimation of 1 month or less, the error of the composite estimate is substantially lower than error of the OLSR estimate.
Spectrofluorimetric determination of fluoroquinolones in pharmaceutical preparations.
Ulu, Sevgi Tatar
2009-02-01
Simple, rapid and highly sensitive spectrofluorimetric method is presented for the determination of four fluoroquinolone (FQ) drugs, ciprofloxacin, enoxacin, norfloxacin and moxifloxacin in pharmaceutical preparations. Proposed method is based on the derivatization of FQ with 4-chloro-7-nitrobenzofurazan (NBD-Cl) in borate buffer of pH 9.0 to yield a yellow product. The optimum experimental conditions have been studied carefully. Beer's law is obeyed over the concentration range of 23.5-500 ng mL(-1) for ciprofloxacin, 28.5-700 ng mL(-1) for enoxacin, 29.5-800 ng mL(-1) for norfloxacin and 33.5-1000 ng mL(-1) for moxifloxacin using NBD-Cl reagent, respectively. The detection limits were found to be 7.0 ng mL(-1) for ciprofloxacin, 8.5 ng mL(-1) for enoxacin, 9.2 ng mL(-1) for norfloxacin and 9.98 ng mL(-1) for moxifloxacin, respectively. Intra-day and inter-day relative standard deviation and relative mean error values at three different concentrations were determined. The low relative standard deviation values indicate good precision and high recovery values indicate accuracy of the proposed methods. The method is highly sensitive and specific. The results obtained are in good agreement with those obtained by the official and reference method. The results presented in this report show that the applied spectrofluorimetric method is acceptable for the determination of the four FQ in the pharmaceutical preparations. Common excipients used as additives in pharmaceutical preparations do not interfere with the proposed method.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Scott D.; Liezers, Martin; Antolick, Kathryn C.
2013-06-13
In this study, we investigated several porous chromatographic materials as synthetic substrates for preparing surrogate nuclear explosion debris particles. The resulting synthetic debris materials are of interest for use in developing analytical methods. Eighteen metals, including some of forensic interest, were loaded onto materials by immersing them in metal solutions (556 mg/L of each metal) to fill the pores, applying gentle heat (110°C) to drive off water, and then treating them at high temperatures (up to 800°C) in air to form less soluble metal species. High-boiling-point metals were uniformly loaded on spherical controlled-pore glass to emulate early fallout, whereas low-boiling-pointmore » metals were loaded on core-shell silica to represent coated particles formed later in the nuclear fallout-formation process. Analytical studies were applied to characterize solubility, material balance, and formation of recalcitrant species. Dissolution experiments indicated loading was 1.5 to 3 times higher than expected from the pore volume alone, a result attributed to surface coating. Analysis of load solutions before and after filling the material pores revealed that most metals were passively loaded; that is, solutions filled the pores without active metal discrimination. However, niobium and tin concentrations were lower in solutions after pore filling, and were found in elevated concentrations in the final products, indicating some metals were selectively loaded. High-temperature treatments caused reduced solubility of several metal species, and loss of some metals (rhenium and tellurium) because volatile species were formed. Sample preparation reproducibility was high (the inter-batch relative standard deviation was 7.8%, and the intra-batch relative standard deviation was 0.84%) indicating that this material is suitable for use as a working standard for analytical methods development. We anticipate future standardized radionuclide-loaded materials will find use in radioanalytical methods development and/or serve as a starting material for the synthesis of more complex forms of nuclear explosion debris (e.g., Trinitite).« less
Crépet, Amélie; Albert, Isabelle; Dervin, Catherine; Carlin, Frédéric
2007-01-01
A normal distribution and a mixture model of two normal distributions in a Bayesian approach using prevalence and concentration data were used to establish the distribution of contamination of the food-borne pathogenic bacteria Listeria monocytogenes in unprocessed and minimally processed fresh vegetables. A total of 165 prevalence studies, including 15 studies with concentration data, were taken from the scientific literature and from technical reports and used for statistical analysis. The predicted mean of the normal distribution of the logarithms of viable L. monocytogenes per gram of fresh vegetables was −2.63 log viable L. monocytogenes organisms/g, and its standard deviation was 1.48 log viable L. monocytogenes organisms/g. These values were determined by considering one contaminated sample in prevalence studies in which samples are in fact negative. This deliberate overestimation is necessary to complete calculations. With the mixture model, the predicted mean of the distribution of the logarithm of viable L. monocytogenes per gram of fresh vegetables was −3.38 log viable L. monocytogenes organisms/g and its standard deviation was 1.46 log viable L. monocytogenes organisms/g. The probabilities of fresh unprocessed and minimally processed vegetables being contaminated with concentrations higher than 1, 2, and 3 log viable L. monocytogenes organisms/g were 1.44, 0.63, and 0.17%, respectively. Introducing a sensitivity rate of 80 or 95% in the mixture model had a small effect on the estimation of the contamination. In contrast, introducing a low sensitivity rate (40%) resulted in marked differences, especially for high percentiles. There was a significantly lower estimation of contamination in the papers and reports of 2000 to 2005 than in those of 1988 to 1999 and a lower estimation of contamination of leafy salads than that of sprouts and other vegetables. The interest of the mixture model for the estimation of microbial contamination is discussed. PMID:17098926
Grabarczyk, Malgorzata; Korolczuk, Mieczyslaw
2010-03-15
A simple and fast cathodic stripping voltammetric procedure for determination of trace quantity of Se(IV) in natural samples containing high concentrations of surfactants and humic substances was developed. The procedure exploiting selenium accumulation (from sample solution spiked with 0.1 mol L(-1) HClO(4) and 4 x 10(-4)mol L(-1) Cu(NO(3))(2)) as Cu(2)Se was employed as the initial method. The deposited Cu(2)Se was stripped by differential pulse cathodic potential scan. The interference from dissolved organic matter such as surfactants and humic substances was eliminated by adding Amberlite XAD-7 resin to the voltammetric cell. The whole procedure was applied to a single cell, which allows one to monitor the voltammetric scan. Optimum conditions for removing the surfactants and humic substances due to their adsorption on XAD-7 resin were evaluated. The method was tested on synthetic samples spiked with surfactants and humic substances. The calibration graph for Se(IV) under optimized conditions following the accumulation of 30s was linear in the range from 2 x 10(-9) to 2 x 10(-7)mol L(-1) and was found to obey the equation y=0.74x-0.61, where y and x are the peak current (nA) and Se(IV) concentration (nmol L(-1)), respectively. The linear correlation coefficient was r=0.9993. The relative standard deviation for determination of Se(IV) at the concentration of 1 x 10(-8)mol L(-1) was 3.7% (n=5). The detection limit estimated from three times the standard deviation for low Se(IV) concentration and accumulation time of 30s was about 7.8 x 10(-10)mol L(-1). The presented procedure was successfully applied to selenium determination in TMRAIN-95 certified reference material and to real samples including spiked lake and river waters for selenium speciation. (c) 2009 Elsevier B.V. All rights reserved.
Yu, Peiran; Hu, Qingjing; Li, Kai; Zhu, Yujiao; Liu, Xiaohuan; Gao, Huiwang; Yao, Xiaohong
2016-12-01
In this study, we characterized dimethylaminium (DMA + ) and trimethylaminium (TMA + ) in size-segregated atmospheric particles during three cruise campaigns in the marginal seas of China and one cruise campaign mainly in the northwest Pacific Ocean (NWPO). An 14-stage nano-MOUDI sampler was utilized for sampling atmospheric particles ranging from 18μm to 0.010μm. Among the four cruise campaigns, the highest concentrations of DMA + and TMA + in PM 10 were observed over the South Yellow Sea (SYS) in August 2015, i.e., 0.76±0.12nmolm -3 for DMA + (average value±standard deviation) and 0.93±0.13nmolm -3 for TMA + . The lowest values were observed over the NWPO in April 2015, i.e., 0.28±0.16nmolm -3 for DMA + and 0.22±0.12nmolm -3 for TMA + . In general, size distributions of the two ions exhibited a bi-modal pattern, i.e., one mode at 0.01-0.1μm and the other at 0.1-1.8μm. The two ions' mode at 0.01-0.1μm was firstly observed. The mode was largely enhanced in samples collected over the SYS in August 2015, leading to high mole ratios of (DMA + +TMA + )/NH 4 + in PM 0.1 (0.4±0.8, median value±standard deviation) and the ions' concentrations in PM 0.1 accounting for ~10% and ~40% of their corresponding concentrations in PM 10 . This implied that (DMA + +TMA + ) likely played an important role in neutralizing acidic species in the smaller particles. Using SO 4 2- , NO 3 - and NH 4 + as references, we confirm that the elevated concentrations of DMA + and TMA + in the 0.01-0.1μm size range were probably real signals rather than sampling artifacts. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Keke; Li, Ming; Li, Hongmei; Li, Mengwan; Jiang, You; Fang, Xiang
2016-01-01
Ambient ionization (AI) techniques have been widely used in chemistry, medicine, material science, environmental science, forensic science. AI takes advantage of direct desorption/ionization of chemicals in raw samples under ambient environmental conditions with minimal or no sample preparation. However, its quantitative accuracy is restricted by matrix effects during the ionization process. To improve the quantitative accuracy of AI, a matrix reference material, which is a particular form of measurement standard, was coupled to an AI technique in this study. Consequently the analyte concentration in a complex matrix can be easily quantified with high accuracy. As a demonstration, this novel method was applied for the accurate quantification of creatinine in serum by using extractive electrospray ionization (EESI) mass spectrometry. Over the concentration range investigated (0.166 ~ 1.617 μg/mL), a calibration curve was obtained with a satisfactory linearity (R2 = 0.994), and acceptable relative standard deviations (RSD) of 4.6 ~ 8.0% (n = 6). Finally, the creatinine concentration value of a serum sample was determined to be 36.18 ± 1.08 μg/mL, which is in excellent agreement with the certified value of 35.16 ± 0.39 μg/mL.
NASA Astrophysics Data System (ADS)
Debry, Edouard; Mallet, Vivien; Garaud, Damien; Malherbe, Laure; Bessagnet, Bertrand; Rouïl, Laurence
2010-05-01
Prev'Air is the French operational system for air pollution forecasting. It is developed and maintained by INERIS with financial support from the French Ministry for Environment. On a daily basis it delivers forecasts up to three days ahead for ozone, nitrogene dioxide and particles over France and Europe. Maps of concentration peaks and daily averages are freely available to the general public. More accurate data can be provided to customers and modelers. Prev'Air forecasts are based on the Chemical Transport Model CHIMERE. French authorities rely more and more on this platform to alert the general public in case of high pollution events and to assess the efficiency of regulation measures when such events occur. For example the road speed limit may be reduced in given areas when the ozone level exceeds one regulatory threshold. These operational applications require INERIS to assess the quality of its forecasts and to sensitize end users about the confidence level. Indeed concentrations always remain an approximation of the true concentrations because of the high uncertainty on input data, such as meteorological fields and emissions, because of incomplete or inaccurate representation of physical processes, and because of efficiencies in numerical integration [1]. We would like to present in this communication the uncertainty analysis of the CHIMERE model led in the framework of an INERIS research project aiming, on the one hand, to assess the uncertainty of several deterministic models and, on the other hand, to propose relevant indicators describing air quality forecast and their uncertainty. There exist several methods to assess the uncertainty of one model. Under given assumptions the model may be differentiated into an adjoint model which directly provides the concentrations sensitivity to given parameters. But so far Monte Carlo methods seem to be the most widely and oftenly used [2,3] as they are relatively easy to implement. In this framework one probability density function (PDF) is associated with an input parameter, according to its assumed uncertainty. Then the combined PDFs are propagated into the model, by means of several simulations with randomly perturbed input parameters. One may then obtain an approximation of the PDF of modeled concentrations, provided the Monte Carlo process has reasonably converged. The uncertainty analysis with CHIMERE has been led with a Monte Carlo method on the French domain and on two periods : 13 days during January 2009, with a focus on particles, and 28 days during August 2009, with a focus on ozone. The results show that for the summer period and 500 simulations, the time and space averaged standard deviation for ozone is 16 µg/m3, to be compared with an averaged concentration of 89 µg/m3. It is noteworthy that the space averaged standard deviation for ozone is relatively constant over time (the standard deviation of the timeseries itself is 1.6 µg/m3). The space variation of the ozone standard deviation seems to indicate that emissions have a significant impact, followed by western boundary conditions. Monte Carlo simulations are then post-processed by both ensemble [4] and Bayesian [5] methods in order to assess the quality of the uncertainty estimation. (1) Rao, K.S. Uncertainty Analysis in Atmospheric Dispersion Modeling, Pure and Applied Geophysics, 2005, 162, 1893-1917. (2) Beekmann, M. and Derognat, C. Monte Carlo uncertainty analysis of a regional-scale transport chemistry model constrained by measurements from the Atmospheric Pollution Over the Paris Area (ESQUIF) campaign, Journal of Geophysical Research, 2003, 108, 8559-8576. (3) Hanna, S.R. and Lu, Z. and Frey, H.C. and Wheeler, N. and Vukovich, J. and Arunachalam, S. and Fernau, M. and Hansen, D.A. Uncertainties in predicted ozone concentrations due to input uncertainties for the UAM-V photochemical grid model applied to the July 1995 OTAG domain, Atmospheric Environment, 2001, 35, 891-903. (4) Mallet, V., and B. Sportisse (2006), Uncertainty in a chemistry-transport model due to physical parameterizations and numerical approximations: An ensemble approach applied to ozone modeling, J. Geophys. Res., 111, D01302, doi:10.1029/2005JD006149. (5) Romanowicz, R. and Higson, H. and Teasdale, I. Bayesian uncertainty estimation methodology applied to air pollution modelling, Environmetrics, 2000, 11, 351-371.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 4 2010-01-01 2010-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 4 2012-01-01 2012-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 4 2014-01-01 2014-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 4 2013-01-01 2013-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 4 2011-01-01 2011-01-01 false Deviations. 961.4 Section 961.4 Energy DEPARTMENT OF ENERGY STANDARD CONTRACT FOR DISPOSAL OF SPENT NUCLEAR FUEL AND/OR HIGH-LEVEL RADIOACTIVE WASTE General § 961.4 Deviations. Requests for authority to deviate from this part shall be submitted in writing to...
Santric-Milicevic, M; Vasic, V; Terzic-Supic, Z
2016-08-15
In times of austerity, the availability of econometric health knowledge assists policy-makers in understanding and balancing health expenditure with health care plans within fiscal constraints. The objective of this study is to explore whether the health workforce supply of the public health care sector, population number, and utilization of inpatient care significantly contribute to total health expenditure. The dependent variable is the total health expenditure (THE) in Serbia from the years 2003 to 2011. The independent variables are the number of health workers employed in the public health care sector, population number, and inpatient care discharges per 100 population. The statistical analyses include the quadratic interpolation method, natural logarithm and differentiation, and multiple linear regression analyses. The level of significance is set at P < 0.05. The regression model captures 90 % of all variations of observed dependent variables (adjusted R square), and the model is significant (P < 0.001). Total health expenditure increased by 1.21 standard deviations, with an increase in health workforce growth rate by 1 standard deviation. Furthermore, this rate decreased by 1.12 standard deviations, with an increase in (negative) population growth rate by 1 standard deviation. Finally, the growth rate increased by 0.38 standard deviation, with an increase of the growth rate of inpatient care discharges per 100 population by 1 standard deviation (P < 0.001). Study results demonstrate that the government has been making an effort to control strongly health budget growth. Exploring causality relationships between health expenditure and health workforce is important for countries that are trying to consolidate their public health finances and achieve universal health coverage at the same time.
Radiochemical Determination of Metallic Mercury Vapour in Air
Magos, L.
1966-01-01
A radiochemical method has been developed for the estimation of atmospheric mercury. When air containing mercury is passed through a solution of 203Hg-mercuric acetate and KCL, isotope exchange takes place so that the issuing air contains the same concentration of mercury, but labelled and with the same specific activity as the reagent solution. The 203Hg is absorbed on hopcalite and estimated by gamma scintillation counting. The standard deviation of the method is 0·004 μg.Hg/litre in concentrations up to 0·2 μg.Hg/litre, and is 0·075 μg.Hg/litre in the range 0·2-1·2 μg.Hg/litre concentration. The method is simple and can be used for snap or long-run sampling, and with continuous recording. PMID:5946132
The truly remarkable universality of half a standard deviation: confirmation through another look.
Norman, Geoffrey R; Sloan, Jeff A; Wyrwich, Kathleen W
2004-10-01
In this issue of Expert Review of Pharmacoeconomics and Outcomes Research, Farivar, Liu, and Hays present their findings in 'Another look at the half standard deviation estimate of the minimally important difference in health-related quality of life scores (hereafter referred to as 'Another look') . These researchers have re-examined the May 2003 Medical Care article 'Interpretation of changes in health-related quality of life: the remarkable universality of half a standard deviation' (hereafter referred to as 'Remarkable') in the hope of supporting their hypothesis that the minimally important difference in health-related quality of life measures is undoubtedly closer to 0.3 standard deviations than 0.5. Nonetheless, despite their extensive wranglings with the exclusion of many articles that we included in our review; the inclusion of articles that we did not include in our review; and the recalculation of effect sizes using the absolute value of the mean differences, in our opinion, the results of the 'Another look' article confirm the same findings in the 'Remarkable' paper.
Static Scene Statistical Non-Uniformity Correction
2015-03-01
Error NUC Non-Uniformity Correction RMSE Root Mean Squared Error RSD Relative Standard Deviation S3NUC Static Scene Statistical Non-Uniformity...Deviation ( RSD ) which normalizes the standard deviation, σ, to the mean estimated value, µ using the equation RS D = σ µ × 100. The RSD plot of the gain...estimates is shown in Figure 4.1(b). The RSD plot shows that after a sample size of approximately 10, the different photocount values and the inclusion
Effect of multizone refractive multifocal contact lenses on standard automated perimetry.
Madrid-Costa, David; Ruiz-Alcocer, Javier; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa
2012-09-01
The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% on pattern deviation probability plots were determined and compared between multifocal and monofocal CLs. Thirty eyes of 30 subjects were included in this study. There were no statistically significant differences in reliability indices or test duration. There was a statistically significant reduction in the MD with the multifocal CL compared with monfocal CL (P=0.001). Differences were not found in PSD nor in the number of depressed points deviating at P<5%, P<2%, P<1%, and P<0.5% in the pattern deviation probability maps studied. The results of this study suggest that the multizone refractive lens produces a generalized depression in threshold sensitivity as measured by the Humphreys 24-2 SITA SAP.
Sert, Şenol
2013-07-01
A comparison method for the determination (without sample pre-concentration) of uranium in ore by inductively coupled plasma optical emission spectrometry (ICP-OES) has been performed. The experiments were conducted using three procedures: matrix matching, plasma optimization, and internal standardization for three emission lines of uranium. Three wavelengths of Sm were tested as internal standard for the internal standardization method. The robust conditions were evaluated using applied radiofrequency power, nebulizer argon gas flow rate, and sample uptake flow rate by considering the intensity ratio of the Mg(II) 280.270 nm and Mg(I) 285.213 nm lines. Analytical characterization of method was assessed by limit of detection and relative standard deviation values. The certificated reference soil sample IAEA S-8 was analyzed, and the uranium determination at 367.007 nm with internal standardization using Sm at 359.260 nm has been shown to improve accuracy compared with other methods. The developed method was used for real uranium ore sample analysis.
Kamman, Neil C; Burgess, Neil M; Driscoll, Charles T; Simonin, Howard A; Goodale, Wing; Linehan, Janice; Estabrook, Robert; Hutcheson, Michael; Major, Andrew; Scheuhammer, Anton M; Scruton, David A
2005-03-01
As part of an initiative to assemble and synthesize mercury (Hg) data from environmental matrices across northeastern North America, we analyzed a large dataset comprised of 15,305 records of fish tissue Hg data from 24 studies from New York State to Newfoundland. These data were summarized to provide mean Hg concentrations for 40 fish species and associated families. Detailed analyses were carried out using data for 13 species. Hg in fishes varied by geographic area, waterbody type, and waterbody. The four species with the highest mean Hg concentrations were muskellunge (Esox masquinongy), walleye (Sander vitreus), white perch (Morone americana), and northern pike (Esox luscius). Several species displayed elevated Hg concentrations in reservoirs, relative to lakes and rivers. Normalized deviations from mean tissue levels for yellow perch (Perca flavescens) and brook trout (Salvelinus fontinalis) were mapped, illustrating how Hg concentrations in these species varied across northeastern North America. Certain geographic regions showed generally below or above-average Hg concentrations in fish, while significant heterogeneity was evident across the landscape. The proportion of waterbodies exhibiting exceedances of USEPA's criterion for fish methylmercury ranged from 14% for standard-length brook trout fillets to 42% for standard-length yellow perch fillets. A preliminary correlation analysis showed that fish Hg concentrations were related to waterbody acidity and watershed size.
Relationships between indoor radon concentrations, thermal retrofit and dwelling characteristics.
Collignan, Bernard; Le Ponner, Eline; Mandin, Corinne
2016-12-01
A monitoring campaign was conducted on a sample of more than 3400 dwellings in Brittany, France from 2011 to 2014. The measurements were collected using one passive dosimeter per dwelling over two months during the heating season, according to the NF ISO 11665-8 (2013) standard. Moreover, building characteristics such as the period of construction, construction material, type of foundation, and thermal retrofit were determined using a questionnaire. The final data set consisted of 3233 houses with the measurement results and the questionnaire answers. Multivariate linear regression models were applied to explore the relationships between the indoor radon concentrations and building characteristics, particularly the thermal retrofit. The geometric mean of the indoor radon concentration was 155 Bq m -3 (with a geometric standard deviation of 3). The houses that had undergone a thermal retrofit had a higher average radon concentration than those that had not, which may have been due to a decrease in air permeability of the building envelope following rehabilitation work that did not systematically include proper management of the ventilation. Other building characteristics, primarily the building material and the foundation type, were associated with the indoor radon concentration. The indoor radon concentrations were higher in older houses built with granite or other stone, with a slab-on-grade foundation and without any ventilation system. Copyright © 2016 Elsevier Ltd. All rights reserved.
Stenzel, O; Wilbrandt, S; Wolf, J; Schürmann, M; Kaiser, N; Ristau, D; Ehlers, H; Carstens, F; Schippel, S; Mechold, L; Rauhut, R; Kennedy, M; Bischoff, M; Nowitzki, T; Zöller, A; Hagedorn, H; Reus, H; Hegemann, T; Starke, K; Harhausen, J; Foest, R; Schumacher, J
2017-02-01
Random effects in the repeatability of refractive index and absorption edge position of tantalum pentoxide layers prepared by plasma-ion-assisted electron-beam evaporation, ion beam sputtering, and magnetron sputtering are investigated and quantified. Standard deviations in refractive index between 4*10-4 and 4*10-3 have been obtained. Here, lowest standard deviations in refractive index close to our detection threshold could be achieved by both ion beam sputtering and plasma-ion-assisted deposition. In relation to the corresponding mean values, the standard deviations in band-edge position and refractive index are of similar order.
Closed-form confidence intervals for functions of the normal mean and standard deviation.
Donner, Allan; Zou, G Y
2012-08-01
Confidence interval methods for a normal mean and standard deviation are well known and simple to apply. However, the same cannot be said for important functions of these parameters. These functions include the normal distribution percentiles, the Bland-Altman limits of agreement, the coefficient of variation and Cohen's effect size. We present a simple approach to this problem by using variance estimates recovered from confidence limits computed for the mean and standard deviation separately. All resulting confidence intervals have closed forms. Simulation results demonstrate that this approach performs very well for limits of agreement, coefficients of variation and their differences.
McClure, Foster D; Lee, Jung K
2005-01-01
Sample size formulas are developed to estimate the repeatability and reproducibility standard deviations (Sr and S(R)) such that the actual error in (Sr and S(R)) relative to their respective true values, sigmar and sigmaR, are at predefined levels. The statistical consequences associated with AOAC INTERNATIONAL required sample size to validate an analytical method are discussed. In addition, formulas to estimate the uncertainties of (Sr and S(R)) were derived and are provided as supporting documentation. Formula for the Number of Replicates Required for a Specified Margin of Relative Error in the Estimate of the Repeatability Standard Deviation.
Nicolás, R O
1987-09-15
Different optical analysis of cylindrical-parabolic concentrators were made by utilizing four models of intensity distribution of the solar disk, i.e., square, uniform, real, and Gaussian. In this paper, the validity conditions using such distributions are determined by calculating each model of the intensity distribution on the receiver plane of perfect and nonperfect cylindrical-parabolic concentrators. We call nonperfect concentrators those in which the normal to each differential element of the specular surface departs from its correct position by an angle sigma(epsilon), the possible values of which follow a Gaussian distribution of mean value epsilon and standard deviation sigma(epsilon). In particular, the results obtained with the models considered for a concentrator with an aperture half-angle of 45 degrees are shown and compared. An important conclusion is that for sigma(epsilon) greater, similar 4 mrad, in some cases for sigma(epsilon) greater, similar 2 mrad, the results obtained are practically independent of the model used.
Pleil, Joachim D
2016-01-01
This commentary is the second of a series outlining one specific concept in interpreting biomarkers data. In the first, an observational method was presented for assessing the distribution of measurements before making parametric calculations. Here, the discussion revolves around the next step, the choice of using standard error of the mean or the calculated standard deviation to compare or predict measurement results.
Top down arsenic uncertainty measurement in water and sediments from Guarapiranga dam (Brazil)
NASA Astrophysics Data System (ADS)
Faustino, M. G.; Lange, C. N.; Monteiro, L. R.; Furusawa, H. A.; Marques, J. R.; Stellato, T. B.; Soares, S. M. V.; da Silva, T. B. S. C.; da Silva, D. B.; Cotrim, M. E. B.; Pires, M. A. F.
2018-03-01
Total arsenic measurements assessment regarding legal threshold demands more than average and standard deviation approach. In this way, analytical measurement uncertainty evaluation was conducted in order to comply with legal requirements and to allow the balance of arsenic in both water and sediment compartments. A top-down approach for measurement uncertainties was applied to evaluate arsenic concentrations in water and sediments from Guarapiranga dam (São Paulo, Brazil). Laboratory quality control and arsenic interlaboratory tests data were used in this approach to estimate the uncertainties associated with the methodology.
Development of a screening method for the determination of 49 priority pollutants in soil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiang, P.H.; Grob, R.L.
1986-01-01
A screening procedure was develop for the determination of 49 priority pollutants in soil. An extraction procedure followed by the capillary gas chromatographic technique was used. Dual pH solutions with methylene chloride were used as extraction solvent system; no sample clean-up procedure was applied. Both base/neutral and acid fractions were analyzed on the same capillary column (SPB-1). The relative standard deviation for 5.1 ppm (51 ..mu..g/ 10 g) concentration in zero soil was less than 25%.
Rumsey and Walker_AMT_2016_Table 2.xlsx
Table summarizes instrument precision assessed by collocating the two sample boxes. Precision is quantified as the standard deviation of the residuals of an orthogonal least squares regression of concentrations from the two sample boxes. This allows for an estimation of gradient precision and ultimately gradient and flux detection limits. This dataset is associated with the following publication:Rumsey, I. Application of an online ion chromatography-based instrument for gradient flux measurements of speciated nitrogen and sulfur. ENVIRONMENTAL SCIENCE & TECHNOLOGY. American Chemical Society, Washington, DC, USA, 9(6): 2581-2592, (2016).
1987-09-25
rate constants, k2r using cyclic voltametry . The res tss are expressed in terms of systematic deviations oP sapparent measured" rate constants, k~b(app...concentration was taken to be lum unless otherwise noted. The voltammetric sweep rate was set at 20 V sŕ unless specified otherwise. The general procedure...peaks for the negative- and positive-going potential sweeps have opposite signs, the measured cathodic-anodic peak separation, AEp, will clearly be
A flow injection chemiluminescence system for the determination of isoniazid.
Huang, Y; Zhang, Z; Zhang, D; Lv, J
2000-10-01
A chemiluminescence (CL) flow system is described for the determination of isoniazid based on its enhancement on the chemiluminescence (CL) emission produced upon mixing a hexacyanoferrate(III) solution with an alkaline luminol solution. The system responds linearly to isoniazid concentration in the range 0-1 mg/L with a detection limit (3sigma) of 0.03 microg/L, relative standard deviation (RSD) of 1.2% for 0.1 mg/L isoniazid (n = 11). The system has been successfully applied to the determination of isoniazid in pharmaceutical preparations.
Pirsa, Sajad
2017-04-01
A portable chromatography device and a method were developed to analyze a gas mixture. The device comprises a chromatographic column for separating components of a sample of the gas mixture. It has an air pump coupled to the inlet of a chromatographic column for pumping air and an injector coupled to the inlet of chromatographic column for feeding the sample using the air as a carrier gas. A detector is arranged downstream from and coupled to the outlet of the chromatographic column. The detector is a nanostructure semiconductive microfiber. The device further comprises an evaluation unit arranged and configured to evaluate each detected component to determine the concentration. The designed portable system was used for simultaneous detection of amines. The possibility of applying dispersive liquid-liquid microextraction for the determination of analytes in trace levels is demonstrated. The reproducibility of this method is acceptable, and good standard deviations were obtained. The relative standard deviation value is less than 6% for all analytes. Finally, the method was successfully applied to the extraction and determination of analytes in water samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sequential injection redox or acid-base titration for determination of ascorbic acid or acetic acid.
Lenghor, Narong; Jakmunee, Jaroon; Vilen, Michael; Sara, Rolf; Christian, Gary D; Grudpan, Kate
2002-12-06
Two sequential injection titration systems with spectrophotometric detection have been developed. The first system for determination of ascorbic acid was based on redox reaction between ascorbic acid and permanganate in an acidic medium and lead to a decrease in color intensity of permanganate, monitored at 525 nm. A linear dependence of peak area obtained with ascorbic acid concentration up to 1200 mg l(-1) was achieved. The relative standard deviation for 11 replicate determinations of 400 mg l(-1) ascorbic acid was 2.9%. The second system, for acetic acid determination, was based on acid-base titration of acetic acid with sodium hydroxide using phenolphthalein as an indicator. The decrease in color intensity of the indicator was proportional to the acid content. A linear calibration graph in the range of 2-8% w v(-1) of acetic acid with a relative standard deviation of 4.8% (5.0% w v(-1) acetic acid, n=11) was obtained. Sample throughputs of 60 h(-1) were achieved for both systems. The systems were successfully applied for the assays of ascorbic acid in vitamin C tablets and acetic acid content in vinegars, respectively.
Introducing the Mean Absolute Deviation "Effect" Size
ERIC Educational Resources Information Center
Gorard, Stephen
2015-01-01
This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…
Hopper, John L.
2015-01-01
How can the “strengths” of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors—and that is how risk gradients are interpreted—so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RRs. This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. PMID:26520360
NASA Astrophysics Data System (ADS)
Muji Susantoro, Tri; Wikantika, Ketut; Saepuloh, Asep; Handoyo Harsolumakso, Agus
2018-05-01
Selection of vegetation indices in plant mapping is needed to provide the best information of plant conditions. The methods used in this research are the standard deviation and the linear regression. This research tried to determine the vegetation indices used for mapping the sugarcane conditions around oil and gas fields. The data used in this study is Landsat 8 OLI/TIRS. The standard deviation analysis on the 23 vegetation indices with 27 samples has resulted in the six highest standard deviations of vegetation indices, termed as GRVI, SR, NLI, SIPI, GEMI and LAI. The standard deviation values are 0.47; 0.43; 0.30; 0.17; 0.16 and 0.13. Regression correlation analysis on the 23 vegetation indices with 280 samples has resulted in the six vegetation indices, termed as NDVI, ENDVI, GDVI, VARI, LAI and SIPI. This was performed based on regression correlation with the lowest value R2 than 0,8. The combined analysis of the standard deviation and the regression correlation has obtained the five vegetation indices, termed as NDVI, ENDVI, GDVI, LAI and SIPI. The results of the analysis of both methods show that a combination of two methods needs to be done to produce a good analysis of sugarcane conditions. It has been clarified through field surveys and showed good results for the prediction of microseepages.
Pharmaceuticals in grocery market fish fillets by gas chromatography-mass spectrometry.
Mottaleb, Musavvir Arafat; Stowe, Carly; Johnson, Daniel R; Meziani, Mohammed J; Mottaleb, M Abdul
2016-01-01
Occurrences of pharmaceuticals are evident in aquatic organisms. A reproducible gas chromatography-mass spectrometry (GC-MS) method using selected ion monitoring (SIM) has been used to determine the anti-histamine diphenhydramine (DPH), anti-anxiety diazepam (DZP), anti-seizure carbamazepine (CZP) drugs and their metabolites in grocery stores fish that were homogenized, extracted, pre-concentrated, cleaned up, and examined. Identifications of the compounds in extracts were obtained by comparing similar mass spectral features and retention properties with standards. Among nine frequently detected drugs, only DPH and DZP were observed and ranged from 0.61 to 6.21 and 1.99 to 16.57 ng/g, respectively, in fourteen fish species. These concentration values were lower than the environmental fish. Mean spike recoveries of analytes exceeded 75% with relative standard deviations (RSD)<10%. The statistically-derived method detection limits (MDLs) for nine compounds ranged from 0.13 to 5.56 ng/g. Average surrogate recoveries were 80-85% with 4-9% RSD. Copyright © 2015 Elsevier Ltd. All rights reserved.
Beck, R A; Anes, J M; Savini, L M; Mateer, R A
2000-06-09
The concentration dependent reaction of sulfite with 57Co-labeled hydroxocobalamin (OH57CoCbl) to produce a sulfitocobalamin (SO(3)57CoCbl) adduct served as a quantification strategy for foodborne sulfite residues freely extracted into pH 5.2, 0.05 M acetate buffer. SO(3)57CoCbl was then resolved using SP-Sephadex C-25 gel chromatography and its radiometric detection allowed calculation of a standard logit plot from which unknown sulfite concentrations could be determined. The sulfite detection range was 6.0 nM-0.3 pM with respective relative standard deviations of 4.4-29.4% for 50-microl samples. Individual incidences of foodborne sulfite intolerances provoked by L-cysteine or sulfite additive use in bakery products, which remained undetected using conventional sulfite analytical methods, underscored the quantitative value of the method. The analytical significance and occurrences of detectable sulfides coexisting with foodborne sulfite residues was also addressed.
O'Donoghue, R T; Broderick, B M
2007-09-01
A 5 week monitoring campaign was carried out in Dublin City centre, to establish which site gave a more accurate background city centre estimation: a roof-top or green field site. This background represented a conservative estimate of HC exposure in Dublin City centre, useful for quantifying health effects related to this form of pollution and also for establishing a local background relative to the four surrounding main roads when the wind direction is travelling towards each road with the background receptor upwind. Over the entire monitoring campaign, the lowest concentrations and relative standard deviations were observed at the green field site, regardless of time of day or meteorological effects.
Rodríguez, C; San Andrés, M I; San Andrés, M D; Encinas, T; González, F; Ballesteros, E
2001-04-01
Phenylglyoxal bis(guanylhydrazone) (PGBG) is a synthesized analogue of methylglyoxal bis(guanylhydrazone) (MGBG), which has demonstrated anti-parasitic activity in rabbits. The pharmacokinetic behaviour of PGBG after intravenous administration (10 mg/kg bodyweight) was studied in five rabbits. Plasma concentrations of PGBG were measured by high-performance liquid chromatography. Plasma PGBG concentrations decreased rapidly and were not detectable beyond 90 min after treatment. The mean [+/- standard deviation (SD)] volume of distribution at steady state (Vdss) was 2.19 +/- 0.47 l/kg and the mean plasma clearance value (Cl) was 29.99 +/- 3.98 ml/min kg. This drug is rapidly eliminated from the body in rabbits, having a short elimination half-life (0.93 h) and mean residence time (1.21 h).
NASA Technical Reports Server (NTRS)
Orr, H. D., III; Campbell, S. A.
1975-01-01
A computer program was used to simulate the response of the Gas Filter Correlation Radiometer (GFCR) to changing pollutant levels of CO, SO2, CH4, and NH3 in two model atmospheres. Positive and negative deviations of tau sub alpha of magnitudes 0.01, 0.1, and 1 percent were imposed upon the simulation and the resulting deviations in inferred concentrations were determined. For the CO, CH4, and the higher pressure cell of the NH3 channel, the deviations are less than + or - 12 percent for deviations in tau sub alpha of + or - 0.1 percent, but increase to significantly higher values for larger deviations. For the lower pressure cell of NH3 and for SO2, the deviations in inferred concentration begin to rise sharply between 0.01 and 0.1 percent deviation in tau sub alpha, suggesting that a tighter control on tau sub alpha may be required for these channels.
Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lye, Jessica, E-mail: jessica.lye@arpansa.gov.au; Dunn, Leon; Kenny, John
Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectorsmore » are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ). Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.« less
Aerosol Measurements in the Mid-Atlantic: Trends and Uncertainty
NASA Astrophysics Data System (ADS)
Hains, J. C.; Chen, L. A.; Taubman, B. F.; Dickerson, R. R.
2006-05-01
Elevated levels of PM2.5 are associated with cardiovascular and respiratory problems and even increased mortality rates. In 2002 we ran two commonly used PM2.5 speciation samplers (an IMPROVE sampler and an EPA sampler) in parallel at Fort Meade, Maryland (a suburban site located in the Baltimore- Washington urban corridor). The filters were analyzed at different labs. This experiment allowed us to calculate the 'real world' uncertainties associated with these instruments. The EPA method retrieved a January average PM2.5 mass of 9.3 μg/m3 with a standard deviation of 2.8 μg/m3, while the IMPROVE method retrieved an average mass of 7.3 μg/m3 with a standard deviation of 2.1 μg/m3. The EPA method retrieved a July average PM2.5 mass of 26.4 μg/m3 with a standard deviation of 14.6 μg/m3, while the IMPROVE method retrieved an average mass of 23.3 μg/m3 with a standard deviation of 13.0 μg/m3. We calculated a 5% uncertainty associated with the EPA and IMPROVE methods that accounts for uncertainties in flow control strategies and laboratory analysis. The RMS difference between the two methods in January was 2.1 μg/m3, which is about 25% of the monthly average mass and greater than the uncertainty we calculated. In July the RMS difference between the two methods was 5.2 μg/m3, about 20% of the monthly average mass, and greater than the uncertainty we calculated. The EPA methods retrieve consistently higher concentrations of PM2.5 than the IMPROVE methods on a daily basis in January and July. This suggests a systematic bias possibly resulting from contamination of either of the sampling methods. We reconstructed the mass and found that both samplers have good correlation between reconstructed and gravimetric mass, though the IMPROVE method has slightly better correlation than the EPA method. In January, organic carbon is the largest contributor to PM2.5 mass, and in July both sulfate and organic matter contribute substantially to PM2.5. Source apportionment models suggest that regional and local power plants are the major sources of sulfate, while mobile and vegetative burning factors are the major sources of organic carbon.
[Research on rapid and quantitative detection method for organophosphorus pesticide residue].
Sun, Yuan-Xin; Chen, Bing-Tai; Yi, Sen; Sun, Ming
2014-05-01
The methods of physical-chemical inspection is adopted in the traditional pesticide residue detection, which require a lot of pretreatment processes, are time-consuming and complicated. In the present study, the authors take chlorpyrifos applied widely in the present agricultural field as the research object and propose a rapid and quantitative detection method for organophosphorus pesticide residues. At first, according to the chemical characteristics of chlorpyrifos and comprehensive chromogenic effect of several colorimetric reagents and secondary pollution, the pretreatment of the scheme of chromogenic reaction of chlorpyrifos with resorcin in a weak alkaline environment was determined. Secondly, by analyzing Uv-Vis spectrum data of chlorpyrifos samples whose content were between 0. 5 and 400 mg kg-1, it was confirmed that the characteristic information after the color reaction mainly was concentrated among 360 approximately 400 nm. Thirdly, the full spectrum forecasting model was established based on the partial least squares, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 995 6, standard deviation of calibration (RMSEC) was 2. 814 7 mg kg-1, and standard deviation of verification (RMSEP) was 8. 012 4 mg kg-1. Fourthly, the wavelengths whose center wavelength is 400 nm was extracted as characteristic region to build a forecasting model, whose correlation coefficient of calibration was 0. 999 6, correlation coefficient of prediction reached 0. 999 3, standard deviation of calibration (RMSEC) was 2. 566 7 mg kg-1 , standard deviation of verification (RMSEP) was 4. 886 6 mg kg-1, respectively. At last, by analyzing the near infrared spectrum data of chlorpyrifos samples with contents between 0. 5 and 16 mg kg-1, the authors found that although the characteristics of the chromogenic functional group are not obvious, the change of absorption peaks of resorcin itself in the neighborhood of 5 200 cm-' happens. The above-mentioned experimental results show that the proposed method is effective and feasible for rapid and quantitative detection prediction for organophosphorus pesticide residues. In the method, the information in full spectrum especially UV-Vis spectrum is strengthened by chromogenic reaction of a colorimetric reagent, which provides a new way of rapid detection of pesticide residues for agricultural products in the future.
Faassen, Elisabeth J; Antoniou, Maria G; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda
2016-02-29
Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer's disease and Parkinson's disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D₃BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%-32%), implying that D₃BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.
Collinearity in Least-Squares Analysis
ERIC Educational Resources Information Center
de Levie, Robert
2012-01-01
How useful are the standard deviations per se, and how reliable are results derived from several least-squares coefficients and their associated standard deviations? When the output parameters obtained from a least-squares analysis are mutually independent, as is often assumed, they are reliable estimators of imprecision and so are the functions…
Robust Confidence Interval for a Ratio of Standard Deviations
ERIC Educational Resources Information Center
Bonett, Douglas G.
2006-01-01
Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…
Standard Deviation for Small Samples
ERIC Educational Resources Information Center
Joarder, Anwar H.; Latif, Raja M.
2006-01-01
Neater representations for variance are given for small sample sizes, especially for 3 and 4. With these representations, variance can be calculated without a calculator if sample sizes are small and observations are integers, and an upper bound for the standard deviation is immediate. Accessible proofs of lower and upper bounds are presented for…
Estimating maize water stress by standard deviation of canopy temperature in thermal imagery
USDA-ARS?s Scientific Manuscript database
A new crop water stress index using standard deviation of canopy temperature as an input was developed to monitor crop water status. In this study, thermal imagery was taken from maize under various levels of deficit irrigation treatments in different crop growing stages. The Expectation-Maximizatio...
Experiments with central-limit properties of spatial samples from locally covariant random fields
Barringer, T.H.; Smith, T.E.
1992-01-01
When spatial samples are statistically dependent, the classical estimator of sample-mean standard deviation is well known to be inconsistent. For locally dependent samples, however, consistent estimators of sample-mean standard deviation can be constructed. The present paper investigates the sampling properties of one such estimator, designated as the tau estimator of sample-mean standard deviation. In particular, the asymptotic normality properties of standardized sample means based on tau estimators are studied in terms of computer experiments with simulated sample-mean distributions. The effects of both sample size and dependency levels among samples are examined for various value of tau (denoting the size of the spatial kernel for the estimator). The results suggest that even for small degrees of spatial dependency, the tau estimator exhibits significantly stronger normality properties than does the classical estimator of standardized sample means. ?? 1992.
YALE NATURAL RADIOCARBON MEASUREMENTS. PART VI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stuiver, M.; Deevey, E.S.
1961-01-01
Most of the measurements made since publication of Yale V are included; some measurements, such as a series collected in Greenland, are withneld pending additional information or field work that will make better interpretations possible. In addition to radiocarbon dates of geologic and/or archaeologic interest, recent assays are given of C/sup 14/ in lake waters and other lacustrine materials, now normalized for C/sup 13/ content. The newly accepted convention is followed in expressing normalized C/sup 14/ values as DELTA = delta C/sup 14/ (2 delta C/sup 13/ + 50)STAl + ( delta C/sup 14//1000)! where DELTA is the per milmore » deviation of the C/sup 14/ if the sample from any contemporary standard (whether organic or a carbonate) after correction of sample and/or standard for real age, for the Suess effect, for normal isotopic fractionation, and for deviations of C/sup 14/ content of the age- and pollution- corrected l9th-century wood standard from that of 95% of the NBS oxalic acid standard; delta C/sup 14/ is the measured deviation from 95% of the NBS standard, and delta C/sup 13/ is the deviation from the NBS limestone standard, both in per mil. These assays are variously affected by artificial C/sup 14/ resulting from nuclear tests. (auth)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carter, Kimberly E; Gerdes, Kirk
2013-07-01
A new and complete GC–ICP-MS method is described for direct analysis of trace metals in a gas phase process stream. The proposed method is derived from standard analytical procedures developed for ICP-MS, which are regularly exercised in standard ICP-MS laboratories. In order to implement the method, a series of empirical factors were generated to calibrate detector response with respect to a known concentration of an internal standard analyte. Calibrated responses are ultimately used to determine the concentration of metal analytes in a gas stream using a semi-quantitative algorithm. The method was verified using a traditional gas injection from a GCmore » sampling valve and a standard gas mixture containing either a 1 ppm Xe + Kr mix with helium balance or 100 ppm Xe with helium balance. Data collected for Xe and Kr gas analytes revealed that agreement of 6–20% with the actual concentration can be expected for various experimental conditions. To demonstrate the method using a relevant “unknown” gas mixture, experiments were performed for continuous 4 and 7 hour periods using a Hg-containing sample gas that was co-introduced into the GC sample loop with the xenon gas standard. System performance and detector response to the dilute concentration of the internal standard were pre-determined, which allowed semi-quantitative evaluation of the analyte. The calculated analyte concentrations varied during the course of the 4 hour experiment, particularly during the first hour of the analysis where the actual Hg concentration was under predicted by up to 72%. Calculated concentration improved to within 30–60% for data collected after the first hour of the experiment. Similar results were seen during the 7 hour test with the deviation from the actual concentration being 11–81% during the first hour and then decreasing for the remaining period. The method detection limit (MDL) was determined for the mercury by injecting the sample gas into the system following a period of equilibration. The MDL for Hg was calculated as 6.8 μg · m -3. This work describes the first complete GC–ICP-MS method to directly analyze gas phase samples, and detailed sample calculations and comparisons to conventional ICP-MS methods are provided.« less
Yanagihara, Nobuyuki; Seki, Meikan; Nakano, Masahiro; Hachisuga, Toru; Goto, Yukio
2014-06-01
Disturbance of autonomic nervous activity has been thought to play a role in the climacteric symptoms of postmenopausal women. This study was therefore designed to investigate the relationship between autonomic nervous activity and climacteric symptoms in postmenopausal Japanese women. The autonomic nervous activity of 40 Japanese women with climacteric symptoms and 40 Japanese women without climacteric symptoms was measured by power spectral analysis of heart rate variability using a standard hexagonal radar chart. The scores for climacteric symptoms were determined using the simplified menopausal index. Sympathetic excitability and irritability, as well as the standard deviation of mean R-R intervals in supine position, were significantly (P < 0.01, 0.05, and 0.001, respectively) decreased in women with climacteric symptoms. There was a negative correlation between the standard deviation of mean R-R intervals in supine position and the simplified menopausal index score. The lack of control for potential confounding variables was a limitation of this study. In climacteric women, the standard deviation of mean R-R intervals in supine position is negatively correlated with the simplified menopausal index score.
WE-FG-207B-08: Dual-Energy CT Iodine Accuracy Across Vendors and Platforms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, M; Wood, C; Cody, D
Purpose: Although a major benefit of dual-energy CT is its quantitative capabilities, it is critical to understand how results vary by scanner manufacturer and/or model before making clinical patient management decisions. Each manufacturer utilizes a specific dual-energy CT approach; cross-calibration may be required for facilities with more than one dual-energy CT scanner type. Methods: A solid dual-energy quality control phantom (Gammex, Inc.; Appleton, WI) representing a large body cross-section containing three Iodine inserts (2mg/ml, 5mg/ml, 15 mg/ml) was scanned on these CT systems: GE HD-750 (80/140kVp), prototype GE Revolution CT with GSI (80/140kVp), Siemens Flash (80/140kVp and 100/140kVp), and Philipsmore » IQon (120kVp and 140kVp). Iodine content was measured in units of concentration (mg/ml) from a single 5mm-thick central image. Three to five acquisitions were performed on each scanner platform in order to compute standard deviation. Scan acquisitions were approximately dose-matched (∼25mGy CTDIvol) and image parameters were as consistent as possible (thickness, kernel, no noise reduction applied). Results: Iodine measurement error ranges were −0.24-0.16 mg/ml for the 2mg/ml insert (−12.0 − 8.0%), −0.28–0.26 mg/ml for the 5mg/ml insert (−5.6 − 5.2%), and −1.16−0.99 mg/ml for the 15mg/ml insert (−7.7 − 6.6%). Standard deviations ranged from 0 to 0.19 mg/ml for the repeated acquisitions from each scanner. The average iodine measurement error and standard deviation across all systems and inserts was −0.21 ± 0.48 mg/ml (−1.5 ± 6.48%). The largest absolute measurement error was found in the 15mg/ml iodine insert. Conclusion: There was generally good agreement in Iodine quantification across 3 dual-energy CT manufacturers and 4 scanner models. This was unexpected given the widely different underlying dual-energy CT mechanisms employed. Future work will include additional scanner platforms, independent verification of the Iodine insert standard concentrations (especially the 15 mg/ml insert), and how much measurement variability can be clinically tolerated. This research has been supported by funds from Dr. William Murphy, Jr., the John S. Dunn, Sr. Distinguished Chair in Diagnostic Imaging at MD Anderson Cancer Center.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sleiman, Mohamad; Chen, Sharon; Gilbert, Haley E.
A laboratory method to simulate natural exposure of roofing materials has been reported in a companion article. Here in the current article, we describe the results of an international, nine-participant interlaboratory study (ILS) conducted in accordance with ASTM Standard E691-09 to establish the precision and reproducibility of this protocol. The accelerated soiling and weathering method was applied four times by each laboratory to replicate coupons of 12 products representing a wide variety of roofing categories (single-ply membrane, factory-applied coating (on metal), bare metal, field-applied coating, asphalt shingle, modified-bitumen cap sheet, clay tile, and concrete tile). Participants reported initial and laboratory-agedmore » values of solar reflectance and thermal emittance. Measured solar reflectances were consistent within and across eight of the nine participating laboratories. Measured thermal emittances reported by six participants exhibited comparable consistency. For solar reflectance, the accelerated aging method is both repeatable and reproducible within an acceptable range of standard deviations: the repeatability standard deviation sr ranged from 0.008 to 0.015 (relative standard deviation of 1.2–2.1%) and the reproducibility standard deviation sR ranged from 0.022 to 0.036 (relative standard deviation of 3.2–5.8%). The ILS confirmed that the accelerated aging method can be reproduced by multiple independent laboratories with acceptable precision. In conclusion, this study supports the adoption of the accelerated aging practice to speed the evaluation and performance rating of new cool roofing materials.« less
Trace analysis of high-purity graphite by LA-ICP-MS.
Pickhardt, C; Becker, J S
2001-07-01
Laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been established as a very efficient and sensitive technique for the direct analysis of solids. In this work the capability of LA-ICP-MS was investigated for determination of trace elements in high-purity graphite. Synthetic laboratory standards with a graphite matrix were prepared for the purpose of quantifying the analytical results. Doped trace elements, concentration 0.5 microg g(-1), in a laboratory standard were determined with an accuracy of 1% to +/- 7% and a relative standard deviation (RSD) of 2-13%. Solution-based calibration was also used for quantitative analysis of high-purity graphite. It was found that such calibration led to analytical results for trace-element determination in graphite with accuracy similar to that obtained by use of synthetic laboratory standards for quantification of analytical results. Results from quantitative determination of trace impurities in a real reactor-graphite sample, using both quantification approaches, were in good agreement. Detection limits for all elements of interest were determined in the low ng g(-1) concentration range. Improvement of detection limits by a factor of 10 was achieved for analyses of high-purity graphite with LA-ICP-MS under wet plasma conditions, because the lower background signal and increased element sensitivity.
Brown, KK; Shaw, PB; Mead, KR; Kovein, RJ; Voorhees, RT; Brandes, AR
2016-01-01
The purpose of this project was to research and develop a direct-reading exposure assessment method that combined a real-time location system with a wireless direct-reading personal chemical sensor. The personal chemical sensor was a photoionization device for detecting volatile organic compounds. The combined system was calibrated and tested against the same four standard gas concentrations and calibrated at one standard location and tested at four locations that included the standard locations. Data were wirelessly collected from the chemical sensor every 1.4 seconds, for volatile organic compounds concentration, location, temperature, humidity, and time. Regression analysis of the photo-ionization device voltage response against calibration gases showed the chemical sensor had a limit of detection of 0.2 ppm. The real-time location system was accurate to 13 cm ± 6 cm (standard deviation) in an open area and to 57 cm ± 31 cm in a closed room where the radio frequency has to penetrate drywall-finished walls. The streaming data were collected and graphically displayed as a three-dimensional hazard map for assessment of peak exposure with location. A real-time personal exposure assessment device with indoor positioning was practical and provided new knowledge on direct reading exposure assessment methods. PMID:26786234
Brown, K K; Shaw, P B; Mead, K R; Kovein, R J; Voorhees, R T; Brandes, A R
2016-01-01
The purpose of this article was to research and develop a direct-reading exposure assessment method that combined a real-time location system with a wireless direct-reading personal chemical sensor. The personal chemical sensor was a photoionization device for detecting volatile organic compounds. The combined system was calibrated and tested against the same four standard gas concentrations and calibrated at one standard location and tested at four locations that included the standard locations. Data were wirelessly collected from the chemical sensor every 1.4 sec, for volatile organic compounds concentration, location, temperature, humidity, and time. Regression analysis of the photo-ionization device voltage response against calibration gases showed the chemical sensor had a limit of detection of 0.2 ppm. The real-time location system was accurate to 13 cm ± 6 cm (standard deviation) in an open area and to 57 cm ± 31 cm in a closed room where the radio frequency has to penetrate drywall-finished walls. The streaming data were collected and graphically displayed as a three-dimensional hazard map for assessment of peak exposure with location. A real-time personal exposure assessment device with indoor positioning was practical and provided new knowledge on direct reading exposure assessment methods.
Hollmann, M; Allen, M S; Beede, D K
2011-04-01
Increasing supply of corn distillers grains (CDG) raises questions about the extent to which they can be used in diets of lactating dairy cows. A database of treatment means (n=44) reported in 16 peer-reviewed journal articles published from 1985 to 2008 was developed. The database included response (within study) to a CDG diet compared with the control (no CDG) for milk yield (MY), milk fat concentration and yield, CDG content of the diet, and dietary composition of control and CDG diets (% of dietary dry matter). Additionally, corn grain fermentability was classified as high moisture (n=7) or dry (n=37). Data from studies with diets including more than one grain source (n=8) had been eliminated from the analysis. Dietary concentrations of CDG ranged from 4.2 to 42% across studies. Dietary concentrations in diets containing CDG were 16.8±1.91% (mean±standard deviation) crude protein, 36±15.5% corn silage, 23±8.8% corn grain, and 28±5.8% starch. Responses to CDG were 0.5±2.10 kg/cow per day (mean±standard deviation) for MY, 0.05±0.178 percentage units for milk fat concentration, and 26±77.6 g/cow per day for milk fat yield. Only MY response was related to increasing concentrations of CDG in diets and peaked at 1.2 kg/cow per day for 21% CDG. Diet fermentability was associated with responses. The greatest MY response to CDG was with 24% corn silage or 23% starch, and concentrations greater than 47% corn silage or 32% starch resulted in negative MY responses. Responses in MY differed by level of MY and were often more evident in higher- (>30.0 kg MY/d) than in lower-producing cows. Milk fat concentration response was not related to dietary CDG, but was correlated linearly with milk fat concentration of cows fed the control diet. Milk fat concentration greater than 3.6% for the control treatment was related to a negative milk fat concentration response to CDG, regardless of dietary concentration of CDG. Partially replacing high-moisture corn with CDG increased milk fat concentration by 0.16 percentage units compared with that from dry corn. When formulating diets with CDG, diet fermentability and level of MY (higher vs. lower) must be considered. Concentrations of corn silage and starch must be moderate to optimize lactational responses to CDG. Overall, lactational response to CDG in this database was dependent on diet fermentability and milk fat concentration in the control. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Grossi, Claudia; Vogel, Felix R.; Curcoll, Roger; Àgueda, Alba; Vargas, Arturo; Rodó, Xavier; Morguí, Josep-Anton
2018-04-01
The ClimaDat station at Gredos (GIC3) has been continuously measuring atmospheric (dry air) mixing ratios of carbon dioxide (CO2) and methane (CH4), as well as meteorological parameters, since November 2012. In this study we investigate the atmospheric variability of CH4 mixing ratios between 2013 and 2015 at GIC3 with the help of co-located observations of 222Rn concentrations, modelled 222Rn fluxes and modelled planetary boundary layer heights (PBLHs). Both daily and seasonal changes in atmospheric CH4 can be better understood with the help of atmospheric concentrations of 222Rn (and the corresponding fluxes). On a daily timescale, the variation in the PBLH is the main driver for 222Rn and CH4 variability while, on monthly timescales, their atmospheric variability seems to depend on emission changes. To understand (changing) CH4 emissions, nocturnal fluxes of CH4 were estimated using two methods: the radon tracer method (RTM) and a method based on the EDGARv4.2 bottom-up emission inventory, both using FLEXPARTv9.0.2 footprints. The mean value of RTM-based methane fluxes (FR_CH4) is 0.11 mg CH4 m-2 h-1 with a standard deviation of 0.09 or 0.29 mg CH4 m-2 h-1 with a standard deviation of 0.23 mg CH4 m-2 h-1 when using a rescaled 222Rn map (FR_CH4_rescale). For our observational period, the mean value of methane fluxes based on the bottom-up inventory (FE_CH4) is 0.33 mg CH4 m-2 h-1 with a standard deviation of 0.08 mg CH4 m-2 h-1. Monthly CH4 fluxes based on RTM (both FR_CH4 and FR_CH4_rescale) show a seasonality which is not observed for monthly FE_CH4 fluxes. During January-May, RTM-based CH4 fluxes present mean values 25 % lower than during June-December. This seasonal increase in methane fluxes calculated by RTM for the GIC3 area appears to coincide with the arrival of transhumant livestock at GIC3 in the second half of the year.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bankston, D.C.; Fisher, N.S.
1977-06-01
The development and routine application of a method for the determination of trace levels of barium in microsamples (5-10 mg) of diatom ash is described Acid-dissolved lithium metaborate fusion melts of ash samples are analyzed using a spectrometer/spectrograph equipped with a dc argon plasma jet excitation source and an echelle diffraction grating. Sample, standard, and blank solutions are buffered by lithium contributed by the flux, to a degree sufficient to reduce matrix effects to acceptable levels. Previous barium determinations by other analytical techniques, on seven interlaboratory reference materials, have been used to establish the accuracy of our results. The averagemore » relative standard deviation for the instrumental analyses was 0.07. Using recommended instrument settings, moreover, the lowest concentration of barium visible in synthetic standard solutions lies just below 2 ..mu..g/L, which is equivalent to 2 ..mu..g/g in the ash.« less
Yehia, Ali M
2013-05-15
New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yehia, Ali M.
2013-05-01
New, simple, specific, accurate and precise spectrophotometric technique utilizing ratio spectra is developed for simultaneous determination of two different binary mixtures. The developed ratio H-point standard addition method (RHPSAM) was managed successfully to resolve the spectral overlap in itopride hydrochloride (ITO) and pantoprazole sodium (PAN) binary mixture, as well as, mosapride citrate (MOS) and PAN binary mixture. The theoretical background and advantages of the newly proposed method are presented. The calibration curves are linear over the concentration range of 5-60 μg/mL, 5-40 μg/mL and 4-24 μg/mL for ITO, MOS and PAN, respectively. Specificity of the method was investigated and relative standard deviations were less than 1.5. The accuracy, precision and repeatability were also investigated for the proposed method according to ICH guidelines.
Gilliom, Robert J.; Helsel, Dennis R.
1986-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations, for determining the best performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.
Korsman, John C; Schipper, Aafke M; Hendriks, A Jan
2016-10-04
Species sensitivity distributions (SSDs) are commonly used in regulatory procedures and ecological risk assessments. Yet, most toxicity threshold and risk assessment studies are based on invertebrates and fish. In the present study, no observed effect concentrations (NOECs) specific to birds and mammals were used to derive SSDs and corresponding hazardous concentrations for 5% of the species (HC5 values). This was done for 41 individual substances as well as for subsets of substances aggregated based on their toxic Mode of Action (MoA). In addition, potential differences in SSD parameters (mean and standard deviation) were investigated in relation to MoA and end point (growth, reproduction, and survival). The means of neurotoxic and respirotoxic compounds were significantly lower than those of narcotics, whereas no differences were found between end points. The standard deviations of the SSDs were similar across MoA's and end points. Finally, the SSDs obtained were used in a case study by calculating Ecological Risks (ER) and multisubstance Potentially Affected Fractions of species (msPAF) based on 19 chemicals in 10 Northwestern European estuaries and coastal areas. The assessment showed that the risks were all below 2.6 × 10 -2 . However, the calculated risks underestimate the actual risks of chemicals in these areas because the potential impacts of substances that were not measured in the field or for which no SSD was available were not included in the risk assessment. The SSDs obtained can be used in regulatory procedures and for assessing the impacts of contaminants on birds and mammals from fish contaminants monitoring programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1986-02-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensoredmore » observations, for determining the best performing parameter estimation method for any particular data det. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification.« less
Estimation of distributional parameters for censored trace-level water-quality data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilliom, R.J.; Helsel, D.R.
1984-01-01
A recurring difficulty encountered in investigations of many metals and organic contaminants in ambient waters is that a substantial portion of water-sample concentrations are below limits of detection established by analytical laboratories. Several methods were evaluated for estimating distributional parameters for such censored data sets using only uncensored observations. Their reliabilities were evaluated by a Monte Carlo experiment in which small samples were generated from a wide range of parent distributions and censored at varying levels. Eight methods were used to estimate the mean, standard deviation, median, and interquartile range. Criteria were developed, based on the distribution of uncensored observations,more » for determining the best-performing parameter estimation method for any particular data set. The most robust method for minimizing error in censored-sample estimates of the four distributional parameters over all simulation conditions was the log-probability regression method. With this method, censored observations are assumed to follow the zero-to-censoring level portion of a lognormal distribution obtained by a least-squares regression between logarithms of uncensored concentration observations and their z scores. When method performance was separately evaluated for each distributional parameter over all simulation conditions, the log-probability regression method still had the smallest errors for the mean and standard deviation, but the lognormal maximum likelihood method had the smallest errors for the median and interquartile range. When data sets were classified prior to parameter estimation into groups reflecting their probable parent distributions, the ranking of estimation methods was similar, but the accuracy of error estimates was markedly improved over those without classification. 6 figs., 6 tabs.« less
Chen, Ling; Li, Yufeng; Zhang, Fang; Zhang, Simin; Zhou, Xianghai; Ji, Linong
2018-05-01
We aimed to evaluate the association between serum ferritin levels and incident type 2 diabetes mellitus risk in a Chinese population. This cohort study assessed 2225 Chinese individuals aged 25-75 years. Diabetes mellitus was diagnosed using the 1999 World Health Organization definition with a median follow-up period of 20 months. Cox proportional hazard models were used to estimate adjusted hazard ratios and 95% confidence intervals (CI) for incident diabetes when serum ferritin concentrations increased by one standard deviation. During the follow-up period, 112 cases (62 men and 50 women) of type 2 diabetes mellitus were identified. Baseline serum ferritin levels were higher in the diabetes than the non-diabetes group. After adjusting for age, body mass index, waist circumference, mean arterial pressure, fasting plasma glucose, fasting insulin, hemoglobin A1c, total cholesterol, high-density lipoprotein cholesterol, alanine transaminase and triglyceride levels, family history of diabetes mellitus, pork meat consumption, neutrophil/lymphocyte ratio, education, and annual household income, the hazard ratios for incident diabetes corresponding to one standard deviation increase in serum ferritin levels were 1.17 (95% CI 1.03, 1.34), 1.20 (95% CI 1.003, 1.43), and 1.03 (95% CI 0.82, 1.31) for the total population, men, and women, respectively. High serum ferritin levels were associated with a higher risk of incident type 2 diabetes mellitus independent of traditional risk factors in the total population and men. Copyright © 2018 Elsevier B.V. All rights reserved.
Remote sensing of water and nitrogen stress in broccoli
NASA Astrophysics Data System (ADS)
Elsheikha, Diael-Deen Mohamed
Remote sensing is being used in agriculture for crop management. Ground based remote sensing data acquisition system was used for collection of high spatial and temporal resolution data for irrigated broccoli crop. The system was composed of a small cart that ran back and forth on a rail system that was mounted on a linear move irrigation system. The cart was equipped with a sensor that had 4 discrete wavelengths; 550 nm, 660 nm, 720 nm, and 810 nm, and an infrared thermometer, all had 10 nm bandwidth. A global positioning system was used to indicate the cart position. The study consisted of two parts; the first was to evaluate remotely sensed reflectance and indices in broccoli during the growing season, and determine whether remotely sensed indices or standard deviation of indices can distinguish between nitrogen and water stress in broccoli, and the second part of the study was to evaluate remotely sensed indices and standard deviation of remotely sensed indices in broccoli during daily changes in solar zenith angle. Results indicated that nitrogen was detected using Ratio Vegetation index, RVI, Normalized Difference Vegetation Index, NDVI, Canopy Chlorophyll Concentration Index, CCCI, and also using the reflectance in the Near-Infrared, NIR, bands. The Red reflectance band capability of showing stress was not as clear as the previous indices and bands reflectance. The Canopy Chlorophyll Concentration Index, CCCI, was the most successful index. The Crop Water Stress Index was able to detect water stress but it was highly affected by the solar zenith angle change along the day.
Selection and Classification Using a Forecast Applicant Pool.
ERIC Educational Resources Information Center
Hendrix, William H.
The document presents a forecast model of the future Air Force applicant pool. By forecasting applicants' quality (means and standard deviations of aptitude scores) and quantity (total number of applicants), a potential enlistee could be compared to the forecasted pool. The data used to develop the model consisted of means, standard deviation, and…
NASA Technical Reports Server (NTRS)
Herrman, B. D.; Uman, M. A.; Brantley, R. D.; Krider, E. P.
1976-01-01
The principle of operation of a wideband crossed-loop magnetic-field direction finder is studied by comparing the bearing determined from the NS and EW magnetic fields at various times up to 155 microsec after return stroke initiation with the TV-determined lightning channel base direction. For 40 lightning strokes in the 3 to 12 km range, the difference between the bearings found from magnetic fields sampled at times between 1 and 10 microsec and the TV channel-base data has a standard deviation of 3-4 deg. Included in this standard deviation is a 2-3 deg measurement error. For fields sampled at progressively later times, both the mean and the standard deviation of the difference between the direction-finder bearing and the TV bearing increase. Near 150 microsec, means are about 35 deg and standard deviations about 60 deg. The physical reasons for the late-time inaccuracies in the wideband direction finder and the occurrence of these effects in narrow-band VLF direction finders are considered.
Wavelength selection method with standard deviation: application to pulse oximetry.
Vazquez-Jaccaud, Camille; Paez, Gonzalo; Strojnik, Marija
2011-07-01
Near-infrared spectroscopy provides useful biological information after the radiation has penetrated through the tissue, within the therapeutic window. One of the significant shortcomings of the current applications of spectroscopic techniques to a live subject is that the subject may be uncooperative and the sample undergoes significant temporal variations, due to his health status that, from radiometric point of view, introduce measurement noise. We describe a novel wavelength selection method for monitoring, based on a standard deviation map, that allows low-noise sensitivity. It may be used with spectral transillumination, transmission, or reflection signals, including those corrupted by noise and unavoidable temporal effects. We apply it to the selection of two wavelengths for the case of pulse oximetry. Using spectroscopic data, we generate a map of standard deviation that we propose as a figure-of-merit in the presence of the noise introduced by the living subject. Even in the presence of diverse sources of noise, we identify four wavelength domains with standard deviation, minimally sensitive to temporal noise, and two wavelengths domains with low sensitivity to temporal noise.
How random is a random vector?
NASA Astrophysics Data System (ADS)
Eliazar, Iddo
2015-12-01
Over 80 years ago Samuel Wilks proposed that the "generalized variance" of a random vector is the determinant of its covariance matrix. To date, the notion and use of the generalized variance is confined only to very specific niches in statistics. In this paper we establish that the "Wilks standard deviation" -the square root of the generalized variance-is indeed the standard deviation of a random vector. We further establish that the "uncorrelation index" -a derivative of the Wilks standard deviation-is a measure of the overall correlation between the components of a random vector. Both the Wilks standard deviation and the uncorrelation index are, respectively, special cases of two general notions that we introduce: "randomness measures" and "independence indices" of random vectors. In turn, these general notions give rise to "randomness diagrams"-tangible planar visualizations that answer the question: How random is a random vector? The notion of "independence indices" yields a novel measure of correlation for Lévy laws. In general, the concepts and results presented in this paper are applicable to any field of science and engineering with random-vectors empirical data.
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups.
Hasija, Narender; Bala, Madhu; Goyal, Virender
2014-05-01
Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton's ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton's study. After measuring the teeth on all 100 patients, Bolton's analysis was performed. Results were compared with Bolton's means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85.
Association of auricular pressing and heart rate variability in pre-exam anxiety students.
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-03-25
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety.
Association of auricular pressing and heart rate variability in pre-exam anxiety students
Wu, Wocao; Chen, Junqi; Zhen, Erchuan; Huang, Huanlin; Zhang, Pei; Wang, Jiao; Ou, Yingyi; Huang, Yong
2013-01-01
A total of 30 students scoring between 12 and 20 on the Test Anxiety Scale who had been exhibiting an anxious state > 24 hours, and 30 normal control students were recruited. Indices of heart rate variability were recorded using an Actiheart electrocardiogram recorder at 10 minutes before auricular pressing, in the first half of stimulation and in the second half of stimulation. The results revealed that the standard deviation of all normal to normal intervals and the root mean square of standard deviation of normal to normal intervals were significantly increased after stimulation. The heart rate variability triangular index, very-low-frequency power, low-frequency power, and the ratio of low-frequency to high-frequency power were increased to different degrees after stimulation. Compared with normal controls, the root mean square of standard deviation of normal to normal intervals was significantly increased in anxious students following auricular pressing. These results indicated that auricular pressing can elevate heart rate variability, especially the root mean square of standard deviation of normal to normal intervals in students with pre-exam anxiety. PMID:25206734
Burkhardt, M.R.; Soliven, P.P.; Werner, S.L.; Vaught, D.G.
1999-01-01
A method for determining submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples has been developed. Caffeine is extracted from a 1 L water sample with a 0.5 g graphitized carbon-based solid-phase cartridge, eluted with methylene chloride-methanol (80 + 20, v/v), and analyzed by liquid chromatography with photodiode-array detection. The single-operator method detection limit for organic-free water samples was 0.02 ??g/L. Mean recoveries and relative standard deviations were 93 ?? 13% for organicfree water samples fortified at 0.04 ??g/L and 84 ?? 4% for laboratory reagent spikes fortified at 0.5 ??g/L. Environmental concentrations of caffeine ranged from 0.003 to 1.44 ??g/L in surface water samples and from 0.01 to 0.08 ??g/L in groundwater samples.
Munch, Jean W; Bassett, Margarita V
2006-01-01
N-nitrosodimethylamine (NDMA) is a probable human carcinogen of concern that has been identified as a drinking water contaminant. U.S. Environmental Protection Agency Method 521 has been developed for the analysis of NDMA and 6 additional N-nitrosamines in drinking water at low ng/L concentrations. The method uses solid-phase extraction with coconut charcoal as the sorbent and dichloromethane as the eluent to concentrate 0.50 L water samples to 1 mL. The extracts are analyzed by gas chromatography-chemical ionization tandem mass spectrometry using large-volume injection. Method performance was evaluated in 2 laboratories. Typical analyte recoveries of 87-104% were demonstrated for fortified reagent water samples, and recoveries of 77-106% were demonstrated for fortified drinking water samples. All relative standard deviations on replicate analyses were < 11%.
Garbarino, John R.
1999-01-01
The inductively coupled plasma?mass spectrometric (ICP?MS) methods have been expanded to include the determination of dissolved arsenic, boron, lithium, selenium, strontium, thallium, and vanadium in filtered, acidified natural water. Method detection limits for these elements are now 10 to 200 times lower than by former U.S. Geological Survey (USGS) methods, thus providing lower variability at ambient concentrations. The bias and variability of the method was determined by using results from spike recoveries, standard reference materials, and validation samples. Spike recoveries at 5 to 10 times the method detection limit and 75 micrograms per liter in reagent-water, surface-water, and groundwater matrices averaged 93 percent for seven replicates, although selected elemental recoveries in a ground-water matrix with an extremely high iron sulfate concentration were negatively biased by 30 percent. Results for standard reference materials were within 1 standard deviation of the most probable value. Statistical analysis of the results from about 60 filtered, acidified natural-water samples indicated that there was no significant difference between ICP?MS and former USGS official methods of analysis.
Doyle, E; Fowles, S E; Summerfield, S; White, T J
2002-03-25
A method was developed for the determination of tafenoquine (I) in human plasma using high-performance liquid chromatography-tandem mass spectrometry. Prior to analysis, the protein in plasma samples was precipitated with methanol containing [2H3(15N)]tafenoquine (II) to act as an internal standard. The supernatant was injected onto a Genesis-C18 column without any further clean-up. The mass spectrometer was operated in the positive ion mode, employing a heat assisted nebulisation, electrospray interface. Ions were detected in multiple reaction monitoring mode. The assay required 50 microl of plasma and was precise and accurate within the range 2 to 500 ng/ml. The average within-run and between-run relative standard deviations were < 7% at 2 ng/ml and greater concentrations. The average accuracy of validation standards was generally within +/- 4% of the nominal concentration. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can safely be stored for at least 8 months at approximately -70 degrees C. The method was very robust and has been successfully applied to the analysis of clinical samples from patients and healthy volunteers dosed with I.
Extended analysis of Skylab experiment M558 data
NASA Technical Reports Server (NTRS)
Ukanwa, A. O.
1976-01-01
A careful review of the data from Skylab M558 was made in an effort to explain the apparent anomaly of the existence of radial concentration gradients whereas none should bave been observed. The very close modelling of the experimental axial concentration profiles by the unsteady-state one-dimensional solution of Fick's Law of self-diffusion in liquid zinc, and the condition of initial uniform concentration in the radioactive pellet portion of the experimental specimens would have precluded the appearance of such radial concentration gradients. Statistical analyses were used to test the significance of the observed deviation from radial-concentration homogeneity. A student t-distribution test of significance showed that, at 90% or even at 80% level of significance, there were no significant deviations from uniformity in radial concentrations. It was also concluded that the two likely causes of any deviation that existed were the zinc to zinc-65 bonding procedure and surface phenomena such as surface tension and capillary action.
Offshore fatigue design turbulence
NASA Astrophysics Data System (ADS)
Larsen, Gunner C.
2001-07-01
Fatigue damage on wind turbines is mainly caused by stochastic loading originating from turbulence. While onshore sites display large differences in terrain topology, and thereby also in turbulence conditions, offshore sites are far more homogeneous, as the majority of them are likely to be associated with shallow water areas. However, despite this fact, specific recommendations on offshore turbulence intensities, applicable for fatigue design purposes, are lacking in the present IEC code. This article presents specific guidelines for such loading. These guidelines are based on the statistical analysis of a large number of wind data originating from two Danish shallow water offshore sites. The turbulence standard deviation depends on the mean wind speed, upstream conditions, measuring height and thermal convection. Defining a population of turbulence standard deviations, at a given measuring position, uniquely by the mean wind speed, variations in upstream conditions and atmospheric stability will appear as variability of the turbulence standard deviation. Distributions of such turbulence standard deviations, conditioned on the mean wind speed, are quantified by fitting the measured data to logarithmic Gaussian distributions. By combining a simple heuristic load model with the parametrized conditional probability density functions of the turbulence standard deviations, an empirical offshore design turbulence intensity is determined. For pure stochastic loading (as associated with standstill situations), the design turbulence intensity yields a fatigue damage equal to the average fatigue damage caused by the distributed turbulence intensity. If the stochastic loading is combined with a periodic deterministic loading (as in the normal operating situation), the proposed design turbulence intensity is shown to be conservative.
Estimating extreme stream temperatures by the standard deviate method
NASA Astrophysics Data System (ADS)
Bogan, Travis; Othmer, Jonathan; Mohseni, Omid; Stefan, Heinz
2006-02-01
It is now widely accepted that global climate warming is taking place on the earth. Among many other effects, a rise in air temperatures is expected to increase stream temperatures indefinitely. However, due to evaporative cooling, stream temperatures do not increase linearly with increasing air temperatures indefinitely. Within the anticipated bounds of climate warming, extreme stream temperatures may therefore not rise substantially. With this concept in mind, past extreme temperatures measured at 720 USGS stream gauging stations were analyzed by the standard deviate method. In this method the highest stream temperatures are expressed as the mean temperature of a measured partial maximum stream temperature series plus its standard deviation multiplied by a factor KE (standard deviate). Various KE-values were explored; values of KE larger than 8 were found physically unreasonable. It is concluded that the value of KE should be in the range from 7 to 8. A unit error in estimating KE translates into a typical stream temperature error of about 0.5 °C. Using a logistic model for the stream temperature/air temperature relationship, a one degree error in air temperature gives a typical error of 0.16 °C in stream temperature. With a projected error in the enveloping standard deviate dKE=1.0 (range 0.5-1.5) and an error in projected high air temperature d Ta=2 °C (range 0-4 °C), the total projected stream temperature error is estimated as d Ts=0.8 °C.
NASA Technical Reports Server (NTRS)
Rhoads, James E.; Rigby, Jane Rebecca; Malhotra, Sangeeta; Allam, Sahar; Carilli, Chris; Combes, Francoise; Finkelstein, Keely; Finkelstein, Steven; Frye, Brenda; Gerin, Maryvonne;
2014-01-01
We report on two regularly rotating galaxies at redshift z approx. = 2, using high-resolution spectra of the bright [C microns] 158 micrometers emission line from the HIFI instrument on the Herschel Space Observatory. Both SDSS090122.37+181432.3 ("S0901") and SDSSJ120602.09+514229.5 ("the Clone") are strongly lensed and show the double-horned line profile that is typical of rotating gas disks. Using a parametric disk model to fit the emission line profiles, we find that S0901 has a rotation speed of v sin(i) approx. = 120 +/- 7 kms(sup -1) and a gas velocity dispersion of (standard deviation)g < 23 km s(sup -1) (1(standard deviation)). The best-fitting model for the Clone is a rotationally supported disk having v sin(i) approx. = 79 +/- 11 km s(sup -1) and (standard deviation)g 4 kms(sup -1) (1(standard deviation)). However, the Clone is also consistent with a family of dispersion-dominated models having (standard deviation)g = 92 +/- 20 km s(sup -1). Our results showcase the potential of the [C microns] line as a kinematic probe of high-redshift galaxy dynamics: [C microns] is bright, accessible to heterodyne receivers with exquisite velocity resolution, and traces dense star-forming interstellar gas. Future [C microns] line observations with ALMA would offer the further advantage of spatial resolution, allowing a clearer separation between rotation and velocity dispersion.
Schulze, P.A.; Capel, P.D.; Squillace, P.J.; Helsel, D.R.
1993-01-01
The usefulness and sensitivity, of a portable immunoassay test for the semiquantitative field screening of water samples was evaluated by means of laboratory and field studies. Laboratory results indicated that the tests were useful for the determination of atrazine concentrations of 0.1 to 1.5 μg/L. At a concentration of 1 μg/L, the relative standard deviation in the difference between the regression line and the actual result was about 40 percent. The immunoassay was less sensitive and produced similar errors for other triazine herbicides. After standardization, the test results were relatively insensitive to ionic content and variations in pH (range, 4 to 10), mildly sensitive to temperature changes, and quite sensitive to the timing of the final incubation step, variances in timing can be a significant source of error. Almost all of the immunoassays predicted a higher atrazine concentration in water samples when compared to results of gas chromatography. If these tests are used as a semiquantitative screening tool, this tendency for overprediction does not diminish the tests' usefulness. Generally, the tests seem to be a valuable method for screening water samples for triazine herbicides.
Lijia, Xu; Guo, Jianru; Chen, QianQian; Baoping, Jiang; Zhang, Wei
2014-06-01
A sensitive and selective ultra high performance liquid chromatography-tandem mass spectrometric (UHPLC-MS/MS) method for the determination of phlorizin and phloretin in human plasma has been firstly developed. Samples were prepared after protein precipitation and analyzed on a C18 column interfaced with a triple quadrupole tandem mass spectrometer. Negative electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile-water (0.02% formic acid), using a gradient procedure. The analytes and internal standard dihydroquercetin were both detected by use of multiple reaction monitoring mode. The method was linear in the concentration range of 2.5-1000.0 ng/mL. The lower limit of quantification (LLOQ) was 2.5 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 9.2%. The accuracy determined at three concentrations was within ± 7.3% in terms of relative error. The total run time was 12.0 min. This assay offers advantages in terms of expediency, and suitability for the analysis of phlorizin and phloretin in various biological fluids. Copyright © 2014 Elsevier B.V. All rights reserved.
Occupational Exposure to Polycyclic Aromatic Hydrocarbons in Polish Coke Plant Workers.
Zając, Joanna; Gomółka, Ewa; Maziarz, Barbara; Szot, Wojciech
2016-11-01
Assessment of occupational exposure to polycyclic aromatic hydrocarbons (PAHs) is an urgent and important task to prevent workers' illnesses. 1-Hydroxypyrene is one of the most commonly used biomarkers. The presented study assessed exposure to PAHs molecules among 619 individuals, men working in coke plant. Average number of years spent on working posts in exposition to PAHs was 31.5 years with standard deviation = 5.3. About 35% were smokers with 14.7 cigarettes per day. For each individual, 1-hydroxypyrene concentration in urine samples was measured. Urine 1-hydroxypyrene concentration correlated with air PAHs concentration. Difference between smokers and non-smokers was statistically significant. The median value for post-shift samples was 1.3 µg g -1 and for pre-shift sample concentration reached 0.3 µg g -1 Maximal assessed concentration was 7.6 µg g -1 among pre-shift samples and 27.8 µg g -1 among post-shift samples. The most exposed working posts were coke oven workers and coal derivatives production workers. Results obtained in presented study are relatively low in comparison to other countries or other Polish results but for further improvement a regular measurement of any PAHs' biomarker should be included to standard periodic health examinations for coke plant workers. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, D; Meier, J; Mawlawi, O
Purpose: Use a NEMA-IEC PET phantom to assess the robustness of FDG-PET-based radiomics features to changes in reconstruction parameters across different scanners. Methods: We scanned a NEMA-IEC PET phantom on 3 different scanners (GE Discovery VCT, GE Discovery 710, and Siemens mCT) using a FDG source-to-background ratio of 10:1. Images were retrospectively reconstructed using different iterations (2–3), subsets (21–24), Gaussian filter widths (2, 4, 6mm), and matrix sizes (128,192,256). The 710 and mCT used time-of-flight and point-spread-functions in reconstruction. The axial-image through the center of the 6 active spheres was used for analysis. A region-of-interest containing all spheres was ablemore » to simulate a heterogeneous lesion due to partial volume effects. Maximum voxel deviations from all retrospectively reconstructed images (18 per scanner) was compared to our standard clinical protocol. PET Images from 195 non-small cell lung cancer patients were used to compare feature variation. The ratio of a feature’s standard deviation from the patient cohort versus the phantom images was calculated to assess for feature robustness. Results: Across all images, the percentage of voxels differing by <1SUV and <2SUV ranged from 61–92% and 88–99%, respectively. Voxel-voxel similarity decreased when using higher resolution image matrices (192/256 versus 128) and was comparable across scanners. Taking the ratio of patient and phantom feature standard deviation was able to identify features that were not robust to changes in reconstruction parameters (e.g. co-occurrence correlation). Metrics found to be reasonably robust (standard deviation ratios > 3) were observed for routinely used SUV metrics (e.g. SUVmean and SUVmax) as well as some radiomics features (e.g. co-occurrence contrast, co-occurrence energy, standard deviation, and uniformity). Similar standard deviation ratios were observed across scanners. Conclusions: Our method enabled a comparison of feature variability across scanners and was able to identify features that were not robust to changes in reconstruction parameters.« less
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Myhre, G.; Penner, J. E.; Randles, C.; Samset, B.; Schulz, M.; Yu, H.; Zhou, C.
2012-09-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in nine participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.51 W m-2 and the inter-model standard deviation is 0.70 W m-2, corresponding to a relative standard deviation of 15%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.26 W m-2, and the standard deviation increases to 1.21 W m-2, corresponding to a significant relative standard deviation of 96%. However, the top-of-atmosphere forcing variability owing to absorption is low, with relative standard deviations of 9% clear-sky and 12% all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment, demonstrates that host model uncertainties could explain about half of the overall sulfate forcing diversity of 0.13 W m-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Robust Alternatives to the Standard Deviation in Processing of Physics Experimental Data
NASA Astrophysics Data System (ADS)
Shulenin, V. P.
2016-10-01
Properties of robust estimations of the scale parameter are studied. It is noted that the median of absolute deviations and the modified estimation of the average Gini differences have asymptotically normal distributions and bounded influence functions, are B-robust estimations, and hence, unlike the estimation of the standard deviation, are protected from the presence of outliers in the sample. Results of comparison of estimations of the scale parameter are given for a Gaussian model with contamination. An adaptive variant of the modified estimation of the average Gini differences is considered.
NASA Astrophysics Data System (ADS)
Yang, Miao; Soroka, Inna; Jonsson, Mats
2017-01-01
In the presence of Tris or methanol, hydroxyl radicals in systems of relevance for interfacial radiation chemistry can be quantified indirectly via the Hantzsch method by determining the amount of the scavenging product formaldehyde formed. In this work, the influence of the presence of H2O2 on the Hantzsch method using acetoacetanilide (AAA) as derivatization reagent is studied. The experiments show that the measured CH2O concentration deviates from the actual concentration in the presence of H2O2 and the deviation increases with increasing [H2O2]0/[CH2O]0. The deviation is negative, i.e., the measured formaldehyde concentration is lower than the actual concentration. This leads to an underestimation of the hydroxyl radical production in systems containing significant amount of H2O2. The main reason for the deviation is found to be three coupled equilibria involving H2O2, CH2O and the derivative produced in the Hantzsch method.
40 CFR 63.7751 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... deviations from any emissions limitations (including operating limit), work practice standards, or operation and maintenance requirements, a statement that there were no deviations from the emissions limitations...-of-control during the reporting period. (7) For each deviation from an emissions limitation...
Enantiomer fractions of polychlorinated biphenyls in three selected Standard Reference Materials.
Morrissey, Joshua A; Bleackley, Derek S; Warner, Nicholas A; Wong, Charles S
2007-01-01
The enantiomer composition of six chiral polychlorinated biphenyls (PCBs) were measured in three different certified Standard Reference Materials (SRMs) from the US National Institute of Standards and Technology (NIST): SRM 1946 (Lake Superior fish tissue), SRM 1939a (PCB Congeners in Hudson River Sediment), and SRM 2978 (organic contaminants in mussel tissue--Raritan Bay, New Jersey) to aid in quality assurance/quality control methodologies in the study of chiral pollutants in sediments and biota. Enantiomer fractions (EFs) of PCBs 91, 95, 136, 149, 174, and 183 were measured using a suite of chiral columns by gas chromatography/mass spectrometry. Concentrations of target analytes were in agreement with certified values. Target analyte EFs in reference materials were measured precisely (<2% relative standard deviation), indicating the utility of SRM in quality assurance/control methodologies for analyses of chiral compounds in environmental samples. Measured EFs were also in agreement with previously published analyses of similar samples, indicating that similar enantioselective processes were taking place in these environmental matrices.
Juhel-Gaugain, M; McEvoy, J D; VanGinkel, L A
2000-12-01
The experimental design of a material certification programme is described. The matrix reference materials (RMs) comprised chlortetracycline (CTC)-containing and CTC-free lyophilised porcine liver, kidney and muscle produced under the European Commission's Standards Measurements and Testing (SMT) programme. The aim of the certification programme was to determine accurately and precisely the concentration of CTC and 4-epi-chlortetracycline (epi-CTC) contained in the RMs. A multi-laboratory approach was used to certify analyte concentrations. Participants (n = 19) were instructed to strictly adhere to previously established guidelines. Following the examination of analytical performance criteria, statistical manipulation of results submitted by 13 laboratories, (6 withdrew) allowed an estimate to be made of the true value of the analyte content. The Nalimov test was used for detection of outlying results. The Cochran and Bartlett tests were employed for testing the homogeneity of variances. The normality of results distribution was tested according to the Kolmogorov-Smirnov-Lilliefors test. One-way analysis of variance (ANOVA) was employed to calculate the within and between-laboratory standard deviations, the overall mean and confidence interval for the CTC and epi-CTC content of each of the RMs. Certified values were within or very close to the target concentration ranges specified in the SMT contract. These studies have demonstrated the successful production and certification of CTC-containing and CTC-free porcine RMs.
NASA Astrophysics Data System (ADS)
Ferguson, Glenda K.
1998-12-01
A quantitative high-performance liquid chromatography (HPLC) laboratory experiment which entails the isocratic separation and simultaneous determination of the two active components of a commercial antipsychotic tablet has been developed. The prescription formulation used in this experiment contains amitriptyline hydrochloride (a tricyclic antidepressant) and perphenazine (a tranquilizer). Our experiment makes use of a straightforward HPLC separation on a cyanopropyl-packed column with an acetonitrile:methanol:aqueous monopotassium phosphate mobile phase pumped at a flow rate of 2.0 mL/min. Analytes are detected by UV absorbance at 215 nm. These conditions yield highly symmetrical and well-resolved peaks in less than 5 min after the injection of a mixture. In the experiment, students are given amitriptyline hydrochloride-perphenazine tablets without the manufacturer's labeled composition claim and a stock solution mixture with known concentrations of amitriptyline hydrochloride and perphenazine. They prepare four standards and a pharmaceutical sample of unknown concentration, assay each solution in quadruplicate, and plot average peak areas of the concentrations of the known solutions in the construction of a standard curve. From the mathematical relationships that result, the average masses of amitriptyline hydrochloride and perphenazine in the prescription tablet are determined. Finally, the standard deviations of the mean masses are calculated. The entire laboratory procedure and statistical data analysis can be completed in a single 3-hour period.
Luan, Tian; Fang, Shuang-xi; Zhou, Ling-xi; Wang, Hong-yang; Zhang, Gen
2015-01-01
A high precision GC system with a pulsed discharge helium ionization detector was set up based on the commercial Agilent 7890A gas chromatography. The gas is identified by retention time and the concentration is calculated through the peak height. Detection limit of the system is about 1 x 10(-9) (mole fraction, the same as below). The standard deviation of 140 continuous injections with a standard cylinder( concentration is roughly 600 x 10(-9)) is better than 0.3 x 10(-9). Between 409.30 x 10(-9) and 867.74 x 10(-9) molecular hydrogen mole fractions and peak height have good linear response. By using two standards to quantify the air sample, the precision meets the background molecular hydrogen compatibility goal within the World Meteorological Organization/Global Atmosphere Watch (WMO/GAW) program. Atmospheric molecular hydrogen concentration at Guangzhou urban area was preliminarily measured by this method from January to November 2013. The results show that the atmospheric molecular hydrogen mole fraction varies from 450 x 10(-9) to 700 x 10(-9) during the observation period, with the lowest value at 14:00 (Beijing time, the same as below) and the peak value at 20:00. The seasonal variation of atmospheric hydrogen at Guangzhou area was similar with that of the same latitude stations in northern hemisphere.
Infantile zinc deficiency: Association with autism spectrum disorders
Yasuda, Hiroshi; Yoshida, Kazuya; Yasuda, Yuichi; Tsutsui, Toyoharu
2011-01-01
Elucidation of the pathogenesis and effective treatment of autism spectrum disorders is one of the challenges today. In this study, we examine hair zinc concentrations for 1,967 children with autistic disorders (1,553 males and 414 females), and show considerable association with zinc deficiency. Histogram of hair zinc concentration was non-symmetric with tailing in lower range, and 584 subjects were found to have lower zinc concentrations than −2 standard deviation level of its reference range (86.3–193ppm). The incidence rate of zinc deficiency in infant group aged 0–3 year-old was estimated 43.5 % in male and 52.5 % in female. The lowest zinc concentration of 10.7 ppm was detected in a 2-year-old boy, corresponding to about 1/12 of the control mean level. These findings suggest that infantile zinc deficiency may epigenetically contribute to the pathogenesis of autism and nutritional approach may yield a novel hope for its treatment and prevention. PMID:22355646
Plakas, S M; el Said, K R; Jester, E L; Bencsath, F A; Hayton, W L
1997-01-01
A liquid chromatographic (LC) method was developed for determination of acriflavine (ACR) and proflavine (PRO) residues in channel catfish muscle. Residues were extracted with acidified methanol solution, and extracts were cleaned up with C18 solid-phase extraction columns. Residue concentrations were determined on an LC cyano column, with spectrophotometric detection at 454 nm. Catfish muscle was individually fortified with ACR (purified from commercial product) and PRO at concentrations of 5, 10, 20, 40, and 80 ppb (5 replicates per level). Mean recoveries from fortified muscle at each level ranged from 86 to 95%, with relative standard deviations (RSDs) of 2.5 to 5.7%. The method was applied to incurred residues of ACR and PRO in muscle after waterborne exposure of channel catfish to commercial acriflavine (10 ppm total dye for 4 h). RSDs for incurred residues of ACR and PRO were in the same range as those for fortified muscle. Low residue concentrations (< 1% of exposure water concentration) suggested poor absorption of ACR and PRO in catfish.
Johnson, Jeremiah D; Nessler, Joseph M; Horazdovsky, Ryan D; Vang, Sandy; Thomas, Avis J; Marston, Scott B
2017-03-01
Periprosthetic joint infection is the most common cause of readmissions after total joint arthroplasty (TJA). Intrawound vancomycin powder (VP) has reduced infection rates in spine surgery; however, there are no data regarding VP in primary TJA. Thirty-four TJA patients received 2 g of VP intraoperatively to investigate VP's pharmacokinetics. Serum and wound concentrations were measured at multiple intervals over 24 hours after closure. All serum concentrations were subtherapeutic (<15μg/mL) and peaked 12 hours after closure (4.7μg/mL; standard deviation [SD], 3.2). Wound concentrations were 922 μg/mL (SD, 523) 3 hours after closure and 207 μg/mL (SD, 317) at 24 hours. VP had a half-life of 7.2 hours (95% confidence interval, 7.0-9.3) in TJA wounds. VP produced highly therapeutic intrawound concentrations while yielding low systemic levels in TJA. VP may serve as a safe adjunct in the prevention of periprosthetic joint infection. Copyright © 2015 Elsevier Inc. All rights reserved.
Enhancing reproducibility of SALDI MS detection by concentrating analytes within laser spot.
Teng, Fei; Zhu, Qunyan; Wang, Yalei; Du, Juan; Lu, Nan
2018-03-01
Surface-assisted laser desorption/ionization time-of-flight mass spectrometry (SALDI TOF MS) has become one of the most important analytical methods due to its less interference at low molecular weight range. However, it is still a challenge to obtain a good reproducibility of SALDI TOF MS because of the inhomogeneous distribution of analyte molecules induced by coffee ring effect. We propose a universal and reliable method to eliminate the coffee ring effect by concentrating all the analyte molecules within the laser spot. This method exhibits an excellent reproducibility of spot-to-spot and substrate-to-substrate, and the relative standard deviations (RSDs) for different concentrations are lower than 12.6%. It also performs good linear dependency (R 2 > 0.98) in the log-log plot with the concentration range of 1nM to 1μM, and the limit of detection for R6G is down to 1fmol. Copyright © 2017 Elsevier B.V. All rights reserved.
Jenke, Dennis; Sadain, Salma; Nunez, Karen; Byrne, Frances
2007-01-01
The performance of an ion chromatographic method for measuring citrate and phosphate in pharmaceutical solutions is evaluated. Performance characteristics examined include accuracy, precision, specificity, response linearity, robustness, and the ability to meet system suitability criteria. In general, the method is found to be robust within reasonable deviations from its specified operating conditions. Analytical accuracy is typically 100 +/- 3%, and short-term precision is not more than 1.5% relative standard deviation. The instrument response is linear over a range of 50% to 150% of the standard preparation target concentrations (12 mg/L for phosphate and 20 mg/L for citrate), and the results obtained using a single-point standard versus a calibration curve are essentially equivalent. A small analytical bias is observed and ascribed to the relative purity of the differing salts, used as raw materials in tested finished products and as reference standards in the analytical method. The assay is specific in that no phosphate or citrate peaks are observed in a variety of method-related solutions and matrix blanks (with and without autoclaving). The assay with manual preparation of the eluents is sensitive to the composition of the eluent in the sense that the eluent must be effectively degassed and protected from CO(2) ingress during use. In order for the assay to perform effectively, extensive system equilibration and conditioning is required. However, a properly conditioned and equilibrated system can be used to test a number of samples via chromatographic runs that include many (> 50) injections.
Use of Standard Deviations as Predictors in Models Using Large-Scale International Data Sets
ERIC Educational Resources Information Center
Austin, Bruce; French, Brian; Adesope, Olusola; Gotch, Chad
2017-01-01
Measures of variability are successfully used in predictive modeling in research areas outside of education. This study examined how standard deviations can be used to address research questions not easily addressed using traditional measures such as group means based on index variables. Student survey data were obtained from the Organisation for…
Screen Twice, Cut Once: Assessing the Predictive Validity of Teacher Selection Tools
ERIC Educational Resources Information Center
Goldhaber, Dan; Grout, Cyrus; Huntington-Klein, Nick
2015-01-01
It is well documented that teachers can have profound effects on student outcomes. Empirical estimates find that a one standard deviation increase in teacher quality raises student test achievement by 10 to 25 percent of a standard deviation. More recent evidence shows that the effectiveness of teachers can affect long-term student outcomes, such…
Comparing Measurement Error between Two Different Methods of Measurement of Various Magnitudes
ERIC Educational Resources Information Center
Zavorsky, Gerald S.
2010-01-01
Measurement error is a common problem in several fields of research such as medicine, physiology, and exercise science. The standard deviation of repeated measurements on the same person is the measurement error. One way of presenting measurement error is called the repeatability, which is 2.77 multiplied by the within subject standard deviation.…
Parabolic trough receiver heat loss and optical efficiency round robin 2015/2016
NASA Astrophysics Data System (ADS)
Pernpeintner, Johannes; Schiricke, Björn; Sallaberry, Fabienne; de Jalón, Alberto García; López-Martín, Rafael; Valenzuela, Loreto; de Luca, Antonio; Georg, Andreas
2017-06-01
A round robin for parabolic trough receiver heat loss and optical efficiency in the laboratory was performed between five institutions using five receivers in 2015/2016. Heat loss testing was performed at three cartridge heater test benches and one Joule heating test bench in the temperature range between 100 °C and 550 °C. Optical efficiency testing was performed with two spectrometric test bench and one calorimetric test bench. Heat loss testing results showed standard deviations at the order of 6% to 12 % for most temperatures and receivers and a standard deviation of 17 % for one receiver at 100 °C. Optical efficiency is presented normalized for laboratories showing standard deviations of 0.3 % to 1.3 % depending on the receiver.
Benign positional vertigo and hyperuricaemia.
Adam, A M
2005-07-01
To find out if there is any association between serum uric acid level and positional vertigo. A prospective, case controlled study. A private neurological clinic. All patients presenting with vertigo. Ninety patients were seen in this period with 78 males and 19 females. Mean age was 47 +/- 3 years (at 95% confidence level) with a standard deviation of 12.4. Their mean uric acid level was 442 +/- 16 (at 95% confidence level) with a standard deviation of 79.6 umol/l as compared to 291 +/- 17 (at 95% confidence level) with a standard deviation of 79.7 umol/l in the control group. The P-value was less than 0.001. That there is a significant association between high uric acid and benign positional vertigo.
NASA Technical Reports Server (NTRS)
Clark, P. E.; Andre, C. G.; Adler, I.; Weidner, J.; Podwysocki, M.
1976-01-01
The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.
Screening Samples for Arsenic by Inductively Coupled Plasma-Mass Spectrometry for Treaty Samples
2014-02-01
2.274 3.657 10.06 14.56 30.36 35.93 % RSD : 15.87% 4.375% 2.931% 4.473% 3.349% 3.788% 2.802% 3.883% 3.449% RSD , relative standard deviation 9 Table...107.9% 106.4% Standard Deviation: 0.3171 0.3498 0.8024 2.964 4.526 10.06 13.83 16.38 11.81 % RSD : 5.657% 3.174% 3.035% 5.507% 4.332% 3.795% 2.626...119.1% 116.5% 109.4% 106.8% 105.2% 105.5% 105.8% 108.6% 107.8% Standard Deviation: 0.2379 0.5595 1.173 2.375 2.798 5.973 11.79 15.10 30.54 % RSD
A deviation display method for visualising data in mobile gamma-ray spectrometry.
Kock, Peder; Finck, Robert R; Nilsson, Jonas M C; Ostlund, Karl; Samuelsson, Christer
2010-09-01
A real time visualisation method, to be used in mobile gamma-spectrometric search operations using standard detector systems is presented. The new method, called deviation display, uses a modified waterfall display to present relative changes in spectral data over energy and time. Using unshielded (137)Cs and (241)Am point sources and different natural background environments, the behaviour of the deviation displays is demonstrated and analysed for two standard detector types (NaI(Tl) and HPGe). The deviation display enhances positive significant changes while suppressing the natural background fluctuations. After an initialization time of about 10min this technique leads to a homogeneous display dominated by the background colour, where even small changes in spectral data are easy to discover. As this paper shows, the deviation display method works well for all tested gamma energies and natural background radiation levels and with both tested detector systems.
Castro-Sánchez, Adelaida María; Matarán-Peñarrocha, Guillermo A; Sánchez-Labraca, Nuria; Quesada-Rubio, José Manuel; Granero-Molina, José; Moreno-Lorenzo, Carmen
2011-01-01
Fibromyalgia is a prevalent musculoskeletal disorder associated with widespread mechanical tenderness, fatigue, non-refreshing sleep, depressed mood and pervasive dysfunction of the autonomic nervous system: tachycardia, postural intolerance, Raynaud's phenomenon and diarrhoea. To determine the effects of craniosacral therapy on sensitive tender points and heart rate variability in patients with fibromyalgia. A randomized controlled trial. Ninety-two patients with fibromyalgia were randomly assigned to an intervention group or placebo group. Patients received treatments for 20 weeks. The intervention group underwent a craniosacral therapy protocol and the placebo group received sham treatment with disconnected magnetotherapy equipment. Pain intensity levels were determined by evaluating tender points, and heart rate variability was recorded by 24-hour Holter monitoring. After 20 weeks of treatment, the intervention group showed significant reduction in pain at 13 of the 18 tender points (P < 0.05). Significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement versus baseline values were observed in the intervention group but not in the placebo group. At two months and one year post therapy, the intervention group showed significant differences versus baseline in tender points at left occiput, left-side lower cervical, left epicondyle and left greater trochanter and significant differences in temporal standard deviation of RR segments, root mean square deviation of temporal standard deviation of RR segments and clinical global impression of improvement. Craniosacral therapy improved medium-term pain symptoms in patients with fibromyalgia.
Code of Federal Regulations, 2010 CFR
2010-07-01
... which are distinct from the standard deviation process and specific to the requirements of the Federal... agency request a deviation from the provisions of this part? 102-38.30 Section 102-38.30 Public Contracts... executive agency request a deviation from the provisions of this part? Refer to §§ 102-2.60 through 102-2...
Family structure and childhood anthropometry in Saint Paul, Minnesota in 1918
Warren, John Robert
2017-01-01
Concern with childhood nutrition prompted numerous surveys of children’s growth in the United States after 1870. The Children’s Bureau’s 1918 “Weighing and Measuring Test” measured two million children to produce the first official American growth norms. Individual data for 14,000 children survives from the Saint Paul, Minnesota survey whose stature closely approximated national norms. As well as anthropometry the survey recorded exact ages, street address and full name. These variables allow linkage to the 1920 census to obtain demographic and socioeconomic information. We matched 72% of children to census families creating a sample of nearly 10,000 children. Children in the entire survey (linked set) averaged 0.74 (0.72) standard deviations below modern WHO height-for-age standards, and 0.48 (0.46) standard deviations below modern weight-for-age norms. Sibship size strongly influenced height-for-age, and had weaker influence on weight-for-age. Each additional child six or underreduced height-for-age scores by 0.07 standard deviations (95% CI: −0.03, 0.11). Teenage siblings had little effect on height-forage. Social class effects were substantial. Children of laborers averaged half a standard deviation shorter than children of professionals. Family structure and socio-economic status had compounding impacts on children’s stature. PMID:28943749
Distributions of microbial activities in deep subseafloor sediments
NASA Technical Reports Server (NTRS)
D'Hondt, Steven; Jorgensen, Bo Barker; Miller, D. Jay; Batzke, Anja; Blake, Ruth; Cragg, Barry A.; Cypionka, Heribert; Dickens, Gerald R.; Ferdelman, Timothy; Hinrichs, Kai-Uwe;
2004-01-01
Diverse microbial communities and numerous energy-yielding activities occur in deeply buried sediments of the eastern Pacific Ocean. Distributions of metabolic activities often deviate from the standard model. Rates of activities, cell concentrations, and populations of cultured bacteria vary consistently from one subseafloor environment to another. Net rates of major activities principally rely on electron acceptors and electron donors from the photosynthetic surface world. At open-ocean sites, nitrate and oxygen are supplied to the deepest sedimentary communities through the underlying basaltic aquifer. In turn, these sedimentary communities may supply dissolved electron donors and nutrients to the underlying crustal biosphere.
Mossaad, Ehab; Furuyama, Wakako; Enomoto, Masahiro; Kawai, Satoru; Mikoshiba, Katsuhiko
2015-01-01
A nearly complete reversal of chloroquine (CQ) resistance in the CQ-resistant Plasmodium falciparum K-1 strain, with a significant decrease in the mean ± standard deviation (SD) 50% inhibitory concentration (IC50) from 1,050 ± 95 nM to 14 ± 2 nM, was achieved in vitro by the simultaneous administration of 2-aminoethyl diphenylborinate (2-APB). The CQ resistance-reversing activity of 2-APB, which showed the same efficacy as verapamil, was also observed in an in vivo mouse infection model with the CQ-resistant Plasmodium chabaudi AS(30CQ) strain. PMID:25691631
Quantifying VOC emissions from polymers: A case study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schulze, J.K.; Qasem, J.S.; Snoddy, R.
1996-12-31
Evaluating residual volatile organic compound emissions emanating from low-density polyethylene can pose significant challenges. These challenges include quantifying emissions from: (a) multiple process lines with different operating conditions; (b) several different comonomers; (c) variations of comonomer content in each grade; and (d) over 120 grades of LDPE. This presentation is a Case Study outlining a project to develop grade-specific emission data for low-density polyethylene pellets. This study included extensive laboratory analyses and required the development of a relational database to compile analytical results, calculate the mean concentration and standard deviation, and generate emissions reports.
NASA Technical Reports Server (NTRS)
Spera, David A.
2008-01-01
Equations are developed with which to calculate lift and drag coefficients along the spans of torsionally-stiff rotating airfoils of the type used in wind turbine rotors and wind tunnel fans, at angles of attack in both the unstalled and stalled aerodynamic regimes. Explicit adjustments are made for the effects of aspect ratio (length to chord width) and airfoil thickness ratio. Calculated lift and drag parameters are compared to measured parameters for 55 airfoil data sets including 585 test points. Mean deviation was found to be -0.4 percent and standard deviation was 4.8 percent. When the proposed equations were applied to the calculation of power from a stall-controlled wind turbine tested in a NASA wind tunnel, mean deviation from 54 data points was -1.3 percent and standard deviation was 4.0 percent. Pressure-rise calculations for a large wind tunnel fan deviated by 2.7 percent (mean) and 4.4 percent (standard). The assumption that a single set of lift and drag coefficient equations can represent the stalled aerodynamic behavior of a wide variety of airfoils was found to be satisfactory.
Nonaka, Y; Saito, K; Hanioka, N; Narimatsu, S; Kataoka, H
2009-05-15
A simple and sensitive automated method for determination of aflatoxins (B1, B2, G1, and G2) in nuts, cereals, dried fruits, and spices was developed consisting of in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-mass spectrometry (LC-MS). Aflatoxins were separated within 8 min by high-performance liquid chromatography using a Zorbax Eclipse XDB-C8 column with methanol/acetonitrile (60/40, v/v): 5mM ammonium formate (45:55) as the mobile phase. Electrospray ionization conditions in the positive ion mode were optimized for MS detection of aflatoxins. The pseudo-molecular ions [M+H](+) were used to detect aflatoxins in selected ion monitoring (SIM) mode. The optimum in-tube SPME conditions were 25draw/eject cycles of 40 microL of sample using a Supel-Q PLOT capillary column as an extraction device. The extracted aflatoxins were readily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. Using the in-tube SPME LC-MS with SIM method, good linearity of the calibration curve (r>0.9994) was obtained in the concentration range of 0.05-2.0 ng/mL using aflatoxin M1 as an internal standard, and the detection limits (S/N=3) of aflatoxins were 2.1-2.8 pg/mL. The in-tube SPME method showed >23-fold higher sensitivity than the direct injection method (10 microL injection volume). The within-day and between-day precision (relative standard deviations) at the concentration of 1 ng/mL aflatoxin mixture were below 3.3% and 7.7% (n=5), respectively. This method was applied successfully to analysis of food samples without interference peaks. The recoveries of aflatoxins spiked into nuts and cereals were >80%, and the relative standard deviations were <11.2%. Aflatoxins were detected at <10 ng/g in several commercial food samples.
Validation and Recommendation of Methods to Measure Biogas Production Potential of Animal Manure
Pham, C. H.; Triolo, J. M.; Cu, T. T. T.; Pedersen, L.; Sommer, S. G.
2013-01-01
In developing countries, biogas energy production is seen as a technology that can provide clean energy in poor regions and reduce pollution caused by animal manure. Laboratories in these countries have little access to advanced gas measuring equipment, which may limit research aimed at improving local adapted biogas production. They may also be unable to produce valid estimates of an international standard that can be used for articles published in international peer-reviewed science journals. This study tested and validated methods for measuring total biogas and methane (CH4) production using batch fermentation and for characterizing the biomass. The biochemical methane potential (BMP) (CH4 NL kg−1 VS) of pig manure, cow manure and cellulose determined with the Moller and VDI methods was not significantly different in this test (p>0.05). The biodegradability using a ratio of BMP and theoretical BMP (TBMP) was slightly higher using the Hansen method, but differences were not significant. Degradation rate assessed by methane formation rate showed wide variation within the batch method tested. The first-order kinetics constant k for the cumulative methane production curve was highest when two animal manures were fermented using the VDI 4630 method, indicating that this method was able to reach steady conditions in a shorter time, reducing fermentation duration. In precision tests, the repeatability of the relative standard deviation (RSDr) for all batch methods was very low (4.8 to 8.1%), while the reproducibility of the relative standard deviation (RSDR) varied widely, from 7.3 to 19.8%. In determination of biomethane concentration, the values obtained using the liquid replacement method (LRM) were comparable to those obtained using gas chromatography (GC). This indicates that the LRM method could be used to determine biomethane concentration in biogas in laboratories with limited access to GC. PMID:25049861
Lee, Ji Hyun; Yu, Il Je
2017-11-01
Exposure to the humidifier disinfectant, polyhexamethylene guanidine phosphate (PHMG), in mists generated from ultrasonic humidifiers was studied in a simulation chamber and apartment rooms. PHMG is suspected as a causative agent of lung disease in Korea residences. In the simulation-chamber study, the amount of disinfectant discharged from three different ultrasonic humidifiers was measured. Mists generated at 1, 2, and 4 times the recommended amount of disinfectant were sampled with an impinger, and the effect of relative humidity (RH) on airborne disinfectant concentration was studied by changing RH from 60%-70% to 90%-100%. In addition, particle size distribution (PSD) in mists was measured by scanning mobility particle sizer (SMPS), aerodynamic particle sizer (APS), and Mastersizer. In the apartment study, mists generated from ultrasonic humidifiers were sampled for 6 h in small and large rooms during fall ( n = 10) and winter ( n = 15). In the simulation study, the humidifiers discharged 205 ± 24.6 ml/h of mist at maximum capacity. Concentrations of airborne disinfectant increased with increasing concentration of disinfectant. RH affected airborne disinfectant concentration in the chamber, with increasing concentration with increasing RH. Below RH 70%, no airborne PHMG was detected. PHMG-containing mists generated from ultrasonic humidifier showed various sizes ranging from 149-157 nm to 690-740 nm to larger than 5.4 µm by SMPS, APS, and Mastersizer, respectively. Surface area mean diameter measured by Mastersizer ranged from 5.39 µm to 5.72 µm. In the apartment study conducted during the fall, the geometric mean (GM) and geometric standard deviation (GSD) and arithmetic mean (AM) and standard deviation (SD) of airborne PHMG concentration were 3.22 + 5.13 µg/m 3 and 8.26 ± 12.18 µg/m 3 , respectively. In the winter, GM + GSD and AM ± SD of airborne PHMG concentration were 0.21 + 2.11 µg/m 3 and 0.35 ± 0.62 µg/m 3 , respectively. RH and temperature in the apartment rooms for fall and winter were 22.5 ± 1.7°C, 74.5 ± 15.6% and 22.0 ± 2°C, 51.1 ± 12.9%, respectively. Different RHs in the fall and winter resulted in very different airborne concentrations of disinfectant in the apartment rooms. Exposure levels and PSD of mists generated from ultrasonic humidifiers in apartments are not sufficient to conclude that PHMG causes lung disease in Korean residences.
Characterization of the NASA Langley Arc Heated Scramjet Test Facility Using NO PLIF
NASA Technical Reports Server (NTRS)
Kidd, F. Gray, III; Narayanaswamy, Venkateswaran; Danehy, Paul M.; Inman, Jennifer A.; Bathel, Brett F.; Cabell, Karen F.; Hass, Neal E.; Capriotti, Diego P.; Drozda, Tomasz G.; Johansen, Criag T.
2014-01-01
The nitric oxide planar laser-induced fluorescence (NO PLIF) imaging was used to characterize the air flow of the NASA Langley Arc Heated Scramjet Test Facility (AHSTF) configured with a Mach 6 nozzle. The arc raises the enthalpy of the test gas in AHSTF, producing nitric oxide. Nitric oxide persists as the temperature drops through the nozzle into the test section. NO PLIF was used to qualitatively visualize the flowfield at different experimental conditions, measure the temperature of the gas flow exiting the facility nozzle, and visualize the wave structure downstream of the nozzle at different operating conditions. Uniformity and repeatability of the nozzle flow were assessed. Expansion and compression waves on the free-jet shear layer as the nozzle flow expands into the test section were visualized. The main purpose of these experiments was to assess the uniformity of the NO in the freestream gas for planned experiments, in which NO PLIF will be used for qualitative fuel-mole-fraction sensitive imaging. The shot-to-shot fluctuations in the PLIF signal, caused by variations in the overall laser intensity as well as NO concentration and temperature variations in the flow was 20-25% of the mean signal, as determined by taking the standard deviation of a set of images obtained at constant conditions and dividing by the mean. The fluctuations within individual images, caused by laser sheet spatial variations as well as NO concentration and temperature variations in the flow, were about 28% of the mean in images, determined by taking standard deviation within individual images, dividing by the mean in the same image and averaged over the set of images. Applying an averaged laser sheet intensity correction reduced the within-image intensity fluctuations to about 10% suggesting that the NO concentration is uniform to within 10%. There was no significant difference in flow uniformity between the low and high enthalpy settings. While not strictly quantitative, the temperature maps show qualitative agreement with the computations of the flow.
Seay, Joseph F.; Gregorczyk, Karen N.; Hasselquist, Leif
2016-01-01
Abstract Influences of load carriage and inclination on spatiotemporal parameters were examined during treadmill and overground walking. Ten soldiers walked on a treadmill and overground with three load conditions (00 kg, 20 kg, 40 kg) during level, uphill (6% grade) and downhill (-6% grade) inclinations at self-selected speed, which was constant across conditions. Mean values and standard deviations for double support percentage, stride length and a step rate were compared across conditions. Double support percentage increased with load and inclination change from uphill to level walking, with a 0.4% stance greater increase at the 20 kg condition compared to 00 kg. As inclination changed from uphill to downhill, the step rate increased more overground (4.3 ± 3.5 steps/min) than during treadmill walking (1.7 ± 2.3 steps/min). For the 40 kg condition, the standard deviations were larger than the 00 kg condition for both the step rate and double support percentage. There was no change between modes for step rate standard deviation. For overground compared to treadmill walking, standard deviation for stride length and double support percentage increased and decreased, respectively. Changes in the load of up to 40 kg, inclination of 6% grade away from the level (i.e., uphill or downhill) and mode (treadmill and overground) produced small, yet statistically significant changes in spatiotemporal parameters. Variability, as assessed by standard deviation, was not systematically lower during treadmill walking compared to overground walking. Due to the small magnitude of changes, treadmill walking appears to replicate the spatiotemporal parameters of overground walking. PMID:28149338
Hopper, John L
2015-11-15
How can the "strengths" of risk factors, in the sense of how well they discriminate cases from controls, be compared when they are measured on different scales such as continuous, binary, and integer? Given that risk estimates take into account other fitted and design-related factors-and that is how risk gradients are interpreted-so should the presentation of risk gradients. Therefore, for each risk factor X0, I propose using appropriate regression techniques to derive from appropriate population data the best fitting relationship between the mean of X0 and all the other covariates fitted in the model or adjusted for by design (X1, X2, … , Xn). The odds per adjusted standard deviation (OPERA) presents the risk association for X0 in terms of the change in risk per s = standard deviation of X0 adjusted for X1, X2, … , Xn, rather than the unadjusted standard deviation of X0 itself. If the increased risk is relative risk (RR)-fold over A adjusted standard deviations, then OPERA = exp[ln(RR)/A] = RR(s). This unifying approach is illustrated by considering breast cancer and published risk estimates. OPERA estimates are by definition independent and can be used to compare the predictive strengths of risk factors across diseases and populations. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Mendonca, Filho J.G.; Araujo, C.V.; Borrego, A.G.; Cook, A.; Flores, D.; Hackley, P.; Hower, J.C.; Kern, M.L.; Kommeren, K.; Kus, J.; Mastalerz, Maria; Mendonca, J.O.; Menezes, T.R.; Newman, J.; Ranasinghe, P.; Souza, I.V.A.F.; Suarez-Ruiz, I.; Ujiie, Y.
2010-01-01
The main objective of this work was to study the effect of the kerogen isolation procedures on maturity parameters of organic matter using optical microscopes. This work represents the results of the Organic Matter Concentration Working Group (OMCWG) of the International Committee for Coal and Organic Petrology (ICCP) during the years 2008 and 2009. Four samples have been analysed covering a range of maturity (low and moderate) and terrestrial and marine geological settings. The analyses comprise random vitrinite reflectance measured on both kerogen concentrate and whole rock mounts and fluorescence spectra taken on alginite. Eighteen participants from twelve laboratories from all over the world performed the analyses. Samples of continental settings contained enough vitrinite for participants to record around 50 measurements whereas fewer readings were taken on samples from marine setting. The scatter of results was also larger in the samples of marine origin. Similar vitrinite reflectance values were in general recorded in the whole rock and in the kerogen concentrate. The small deviations of the trend cannot be attributed to the acid treatment involved in kerogen isolation but to reasons related to components identification or to the difficulty to achieve a good polish of samples with high mineral matter content. In samples difficult to polish, vitrinite reflectance was measured on whole rock tended to be lower. The presence or absence of rock fabric affected the selection of the vitrinite population for measurement and this also had an influence in the average value reported and in the scatter of the results. Slightly lower standard deviations were reported for the analyses run on kerogen concentrates. Considering the spectral fluorescence results, it was observed that the ??max presents a shift to higher wavelengths in the kerogen concentrate sample in comparison to the whole-rock sample, thus revealing an influence of preparation methods (acid treatment) on fluorescence properties. ?? 2010 Elsevier B.V.
Su, Yushan; Hung, Hayley
2010-11-01
Measurements of semi-volatile organic chemicals (SVOCs) were compared among 21 laboratories from 7 countries through the analysis of standards, a blind sample, an air extract, and an atmospheric dust sample. Measurement accuracy strongly depended on analytes, laboratories, and types of standards and samples. Intra-laboratory precision was generally good with relative standard deviations (RSDs) of triplicate injections <10% and with median differences of duplicate samples between 2.1 and 22%. Inter-laboratory variability, measured by RSDs of all measurements, was in the range of 2.8-58% in analyzing standards, and 6.9-190% in analyzing blind sample and air extract. Inter-laboratory precision was poorer when samples were subject to cleanup processes, or when SVOCs were quantified at low concentrations. In general, inter-laboratory differences up to a factor of 2 can be expected to analyze atmospheric SVOCs. When comparing air measurements from different laboratories, caution should be exercised if the data variability is less than the inter-laboratory differences. 2010. Published by Elsevier Ltd. All rights reserved.
Maassen, Gerard H
2010-08-01
In this Journal, Lewis and colleagues introduced a new Reliable Change Index (RCI(WSD)), which incorporated the within-subject standard deviation (WSD) of a repeated measurement design as the standard error. In this note, two opposite errors in using WSD this way are demonstrated. First, being the standard error of measurement of only a single assessment makes WSD too small when practice effects are absent. Then, too many individuals will be designated reliably changed. Second, WSD can grow unlimitedly to the extent that differential practice effects occur. This can even make RCI(WSD) unable to detect any reliable change.
Inter-laboratory validation of bioaccessibility testing for metals.
Henderson, Rayetta G; Verougstraete, Violaine; Anderson, Kim; Arbildua, José J; Brock, Thomas O; Brouwers, Tony; Cappellini, Danielle; Delbeke, Katrien; Herting, Gunilla; Hixon, Greg; Odnevall Wallinder, Inger; Rodriguez, Patricio H; Van Assche, Frank; Wilrich, Peter; Oller, Adriana R
2014-10-01
Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (sr) and reproducibility (sR) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the sR:sr ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of sr showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed. Copyright © 2014 Elsevier Inc. All rights reserved.
Wang, Licheng; Hou, Xiudan; Li, Jubai; Liu, Shujuan; Guo, Yong
2015-07-01
A novel graphene oxide decorated with silver nanoparticles coating on a stainless-steel fiber for solid-phase microextraction was prepared. Scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the coating surface and showed that silver nanoparticles were dispersed on the wrinkled graphene oxide surface. Coupled to gas chromatography with flame ionization detection, the extraction abilities of the fiber for polycyclic aromatic hydrocarbons were examined in the headspace solid-phase microextraction mode. The extraction parameters including adsorption time, adsorption temperature, salt concentration, desorption time and desorption temperature were investigated. Under the optimized condition, wide linearity with low limits of detection from 2 to 10 ng/L was obtained. The relative standard deviations for single-fiber repeatability and fiber-to-fiber reproducibility were less than 10.6 and 17.5%, respectively. The enrichment factors were from 1712.5 to 4503.7, showing the fiber has good extraction abilities. Moreover, the fiber exhibited a good stability and could be reused for more than 120 times. The established method was also applied for determination of polycyclic aromatic hydrocarbons in two real water samples and the recoveries of analytes ranged from 84.4-116.3% with relative standard deviations less than 16.2%. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
High precision UTDR measurements by sonic velocity compensation with reference transducer.
Stade, Sam; Kallioinen, Mari; Mänttäri, Mika; Tuuva, Tuure
2014-07-02
An ultrasonic sensor design with sonic velocity compensation is developed to improve the accuracy of distance measurement in membrane modules. High accuracy real-time distance measurements are needed in membrane fouling and compaction studies. The benefits of the sonic velocity compensation with a reference transducer are compared to the sonic velocity calculated with the measured temperature and pressure using the model by Belogol'skii, Sekoyan et al. In the experiments the temperature was changed from 25 to 60 °C at pressures of 0.1, 0.3 and 0.5 MPa. The set measurement distance was 17.8 mm. Distance measurements with sonic velocity compensation were over ten times more accurate than the ones calculated based on the model. Using the reference transducer measured sonic velocity, the standard deviations for the distance measurements varied from 0.6 to 2.0 µm, while using the calculated sonic velocity the standard deviations were 21-39 µm. In industrial liquors, not only the temperature and the pressure, which were studied in this paper, but also the properties of the filtered solution, such as solute concentration, density, viscosity, etc., may vary greatly, leading to inaccuracy in the use of the Belogol'skii, Sekoyan et al. model. Therefore, calibration of the sonic velocity with reference transducers is needed for accurate distance measurements.
Knudsen, Søren Tang; Mosbech, Thomas Hammershaimb; Hansen, Birtha; Kønig, Else; Johnsen, Peter Christian; Kamper, Anne-Lise
2013-12-01
National guidelines recommend strict control of blood pressure (BP) and plasma low-density lipoprotein cholesterol (LDL) in type 2 diabetes (T2DM), aiming at a BP ≤ 130/80 mmHg and an LDL concentration ≤ 2.5 mmol/l. Angiotensin-converting enzyme inhibitors (ACEI) or angiotensin II-receptor blockers (ARB) are recommended as primary antihypertensive therapy (AHT). To which extent these targets are met in Danish primary care is unknown. This study was based on data from 2,057 patients with T2DM who were randomly selected from 64 general practitioners (GPs) from different regions of Denmark. Data were collected from the GPs' electronic records. The mean age ± standard deviation was 66.2 ± 11.6 years; 58.7% were male. The mean systolic BP ± standard deviation was 132.6 ± 14.6 mmHg and the mean diastolic BP ± standard deviation was 78.1 ± 9.0 mmHg. 47.7% of the patients met the BP target. 79.5% of the patients were on AHT. 55.1% of the untreated and 46.0% of the treated patients met the BP target. 83.4% of the treated patients received ACEI or ARB. The median LDL was 2.2 (1.7-2.7) mmol/l. 63.7% of the patients met the LDL target. 73.7% of the patients received lipid-lowering therapy. 32.8% of the untreated and 74.4% of the treated patients met the LDL target. AHT including ACEI and ARB and lipid-lowering therapy are widely used in T2DM in Danish primary care, but only half of the patients are at target for BP and two thirds are at target for LDL. Increased use of diuretics may improve BP control. This study was funded by a grant from Boehringer Ingelheim, Denmark. The grant covered costs related to data collection, time spent by the general practitioners and data analysis by the DTU. not relevant.
NASA Astrophysics Data System (ADS)
Jackson-Edwards, Patrice
Photons from k shell x-ray fluorescence illuminates lead atoms by measuring the characteristic x-rays which indicate the abundance of 210Pb present in a sample. The measurement utilizes a 109Cd source and a low-energy germanium detector, which has emerged as the best available technique for estimating cumulative exposure to lead in adults and for predicting lead-associated risks for adult chronic disease outcomes such as hypertension. The main focus of this study, was to show the correlation between bone lead concentration at the tibia (mean +/- standard deviation of 7+/-1 ppm) and patella (mean +/- standard deviation of 6+/-1 ppm) bone sites and hypertension (mean +/- standard deviation of the systolic standing 143+/-18mmHg, systolic sitting 140+/-17mmHg, diastolic standing 88+/-14 mmHg, and diastolic sitting 81+/-9 mmHg), among the 67 Gadsden County subjects that participated in this study. This was accomplished using FAMU's setup for the detector. The gamma rays emitted by the 109Cd source are scattered by atomic electrons in the k-shell. Excited electrons in the k-shell then spontaneously fluoresce at 88 keV as a signature of lead in the bone. The 88 keV photons are then detected at an angle of 180 degrees with respect to the incident x-ray direction and are detected by the Canberra Germanium solid-state detector bathed in liquid nitrogen. Results show that in this population all lead biomarkers (tibia lead, patella lead, and blood lead) were not significant contributors to the occurrence of hypertension. In the final logistic regression analysis, age and gender were predictors for the occurrence of hypertension at the p<0.05 level in the overall population. This study will help contribute to the understanding of the body's management of lead toxicity and to KXRF techniques currently used in physics research.
Global evaluation and calibration of a passive air sampler for gaseous mercury
NASA Astrophysics Data System (ADS)
McLagan, David S.; Mitchell, Carl P. J.; Steffen, Alexandra; Hung, Hayley; Shin, Cecilia; Stupple, Geoff W.; Olson, Mark L.; Luke, Winston T.; Kelley, Paul; Howard, Dean; Edwards, Grant C.; Nelson, Peter F.; Xiao, Hang; Sheu, Guey-Rong; Dreyer, Annekatrin; Huang, Haiyong; Hussain, Batual Abdul; Lei, Ying D.; Tavshunsky, Ilana; Wania, Frank
2018-04-01
Passive air samplers (PASs) for gaseous mercury (Hg) were deployed for time periods between 1 month and 1 year at 20 sites across the globe with continuous atmospheric Hg monitoring using active Tekran instruments. The purpose was to evaluate the accuracy of the PAS vis-à-vis the industry standard active instruments and to determine a sampling rate (SR; the volume of air stripped of gaseous Hg per unit of time) that is applicable across a wide range of conditions. The sites spanned a wide range of latitudes, altitudes, meteorological conditions, and gaseous Hg concentrations. Precision, based on 378 replicated deployments performed by numerous personnel at multiple sites, is 3.6 ± 3.0 %1, confirming the PAS's excellent reproducibility and ease of use. Using a SR previously determined at a single site, gaseous Hg concentrations derived from the globally distributed PASs deviate from Tekran-based concentrations by 14.2 ± 10 %. A recalibration using the entire new data set yields a slightly higher SR of 0.1354 ± 0.016 m3 day-1. When concentrations are derived from the PAS using this revised SR the difference between concentrations from active and passive sampling is reduced to 8.8 ± 7.5 %. At the mean gaseous Hg concentration across the study sites of 1.54 ng m-3, this represents an ability to resolve concentrations to within 0.13 ng m-3. Adjusting the sampling rate to deployment specific temperatures and wind speeds does not decrease the difference in active-passive concentration further (8.7 ± 5.7 %), but reduces its variability by leading to better agreement in Hg concentrations measured at sites with very high and very low temperatures and very high wind speeds. This value (8.7 ± 5.7 %) represents a conservative assessment of the overall uncertainty of the PAS due to inherent uncertainties of the Tekran instruments. Going forward, the recalibrated SR adjusted for temperature and wind speed should be used, especially if conditions are highly variable or deviate considerably from the average of the deployments in this study (9.89 °C, 3.41 m s-1). Overall, the study demonstrates that the sampler is capable of recording background gaseous Hg concentrations across a wide range of environmental conditions with accuracy similar to that of industry standard active sampling instruments. Results at sites with active speciation units were inconclusive on whether the PASs take up total gaseous Hg or solely gaseous elemental Hg primarily because gaseous oxidized Hg concentrations were in a similar range as the uncertainty of the PAS. 1Subscripted numbers are not significant, but are reported to reduce rounding errors in subsequent studies (see Sect. 2.3 for details).
Gender Differences in Numeracy in Indonesia: Evidence from a Longitudinal Dataset
ERIC Educational Resources Information Center
Suryadarma, Daniel
2015-01-01
This paper uses a rich longitudinal dataset to measure the evolution of the gender differences in numeracy among school-age children in Indonesia. Girls outperformed boys by 0.08 standard deviations when the sample was around 11 years old. Seven years later, the gap has widened to 0.19 standard deviations, equivalent to around 18 months of…
A Survey Data Response to the Teaching of Utility Curves and Risk Aversion
ERIC Educational Resources Information Center
Hobbs, Jeffrey; Sharma, Vivek
2011-01-01
In many finance and economics courses as well as in practice, the concept of risk aversion is reduced to the standard deviation of returns, whereby risk-averse investors prefer to minimize their portfolios' standard deviations. In reality, the concept of risk aversion is richer and more interesting than this, and can easily be conveyed through…
On the Linear Relation between the Mean and the Standard Deviation of a Response Time Distribution
ERIC Educational Resources Information Center
Wagenmakers, Eric-Jan; Brown, Scott
2007-01-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different…
Estimation of Tooth Size Discrepancies among Different Malocclusion Groups
Bala, Madhu; Goyal, Virender
2014-01-01
ABSTRACT Regards and Tribute: Late Dr Narender Hasija was a mentor and visionary in the light of knowledge and experience. We pay our regards with deepest gratitude to the departed soul to rest in peace. Bolton’s ratios help in estimating overbite, overjet relationships, the effects of contemplated extractions on posterior occlusion, incisor relationships and identification of occlusal misfit produced by tooth size discrepancies. Aim: To determine any difference in tooth size discrepancy in anterior as well as overall ratio in different malocclusions and comparison with Bolton’s study. Materials and methods: After measuring the teeth on all 100 patients, Bolton’s analysis was performed. Results were compared with Bolton’s means and standard deviations. The results were also subjected to statistical analysis. Results show that the mean and standard deviations of ideal occlusion cases are comparable with those Bolton but, when the mean and standard deviation of malocclusion groups are compared with those of Bolton, the values of standard deviation are higher, though the mean is comparable. How to cite this article: Hasija N, Bala M, Goyal V. Estimation of Tooth Size Discrepancies among Different Malocclusion Groups. Int J Clin Pediatr Dent 2014;7(2):82-85. PMID:25356005
Darajeh, Negisa; Idris, Azni; Fard Masoumi, Hamid Reza; Nourani, Abolfazl; Truong, Paul; Rezania, Shahabaldin
2017-05-04
Artificial neural networks (ANNs) have been widely used to solve the problems because of their reliable, robust, and salient characteristics in capturing the nonlinear relationships between variables in complex systems. In this study, ANN was applied for modeling of Chemical Oxygen Demand (COD) and biodegradable organic matter (BOD) removal from palm oil mill secondary effluent (POMSE) by vetiver system. The independent variable, including POMSE concentration, vetiver slips density, and removal time, has been considered as input parameters to optimize the network, while the removal percentage of COD and BOD were selected as output. To determine the number of hidden layer nodes, the root mean squared error of testing set was minimized, and the topologies of the algorithms were compared by coefficient of determination and absolute average deviation. The comparison indicated that the quick propagation (QP) algorithm had minimum root mean squared error and absolute average deviation, and maximum coefficient of determination. The importance values of the variables was included vetiver slips density with 42.41%, time with 29.8%, and the POMSE concentration with 27.79%, which showed none of them, is negligible. Results show that the ANN has great potential ability in prediction of COD and BOD removal from POMSE with residual standard error (RSE) of less than 0.45%.
Faassen, Elisabeth J.; Antoniou, Maria G.; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L.; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda
2016-01-01
Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%–32%), implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis. PMID:26938542
222Rn progeny surface deposition and resuspension--residential materials.
Leonard, B E
1995-07-01
The radiological hazard of radon gas to occupants in residential environments is from the particulate progeny 218Po, 214Pb, 214Bi, and 214Po, rather than 222Rn itself. Attachment to aerosols, plateout, and resuspension impact on the progeny airborne concentrations. Plateout rate and resuspension factors were measured for air change (ventilation) rates, 0.01 to 1.0 h-1, in a 0.28 m3 test chamber for interior residential materials of wallboard, drapery, carpet, ceiling tile, and concrete, and from 0.05 to 2.5 h-i for hardwood and glass. The overall accuracy of the plateout rate values is estimated to be +/- 13% standard deviation. For the different materials, the plateout rates for 218Po progeny varied by a factor of nearly six. Drapery gave the largest plateout rates. Resuspension rate factors, R, were measured for hardwood, wallboard, drapery, carpet, and glass by a new time-dependent measurement method based on the difference in buildup rate of 214Po to equilibrium caused by resuspension. Values for R obtained for hardwood, wallboard, drapery, carpet and glass were 0.31, 0.29, 0.44, 0.55, and 0.36, respectively ( +/- 30% standard deviation). All measurements were made in a continuous air conditioned interior environment maintaining temperature at 22.2 +/- 1.1 degrees C and relative humidity of 30% +/- 10%. Computations were made of equivalent plateout rates and equilibrium fractions for a standard 5 m x 5 m x 3 m high room to provide values to compare with other work.
Zaugg, Steven D.; Smith, Steven G.; Schroeder, Michael P.
2006-01-01
A method for the determination of 69 compounds typically found in domestic and industrial wastewater is described. The method was developed in response to increasing concern over the impact of endocrine-disrupting chemicals on aquatic organisms in wastewater. This method also is useful for evaluating the effects of combined sanitary and storm-sewer overflow on the water quality of urban streams. The method focuses on the determination of compounds that are indicators of wastewater or have endocrine-disrupting potential. These compounds include the alkylphenol ethoxylate nonionic surfactants, food additives, fragrances, antioxidants, flame retardants, plasticizers, industrial solvents, disinfectants, fecal sterols, polycyclic aromatic hydrocarbons, and high-use domestic pesticides. Wastewater compounds in whole-water samples were extracted using continuous liquid-liquid extractors and methylene chloride solvent, and then determined by capillary-column gas chromatography/mass spectrometry. Recoveries in reagent-water samples fortified at 0.5 microgram per liter averaged 72 percent ? 8 percent relative standard deviation. The concentration of 21 compounds is always reported as estimated because method recovery was less than 60 percent, variability was greater than 25 percent relative standard deviation, or standard reference compounds were prepared from technical mixtures. Initial method detection limits averaged 0.18 microgram per liter. Samples were preserved by adding 60 grams of sodium chloride and stored at 4 degrees Celsius. The laboratory established a sample holding-time limit prior to sample extraction of 14 days from the date of collection.
Goto, Mikako; Yasuoka, Yumi; Nagahama, Hiroyuki; Muto, Jun; Omori, Yasutaka; Ihara, Hayato; Mukai, Takahiro
2017-04-28
A significant increase in atmospheric radon concentration was observed in the area around the epicentre before and after the occurrence of the shallow inland earthquake in the northern Wakayama Prefecture on 5 July 2011 (Mj 5.5, depth 7 km) in Japan. The seismic activity in the sampling site was evaluated to identify that this earthquake was the largest near the sampling site during the observation period. To determine whether this was an anomalous change, the atmospheric daily minimum radon concentration measured for a 13-year period was analysed. When the residual radon concentration values without the seasonal radon variation and the linear trend was > 3 standard deviations of the residual radon variation corresponding to the normal period, the values were deemed as anomalous. As a result, an anomalous increase in radon concentration was determined before and after the earthquake. In conclusion, anomalous change related to earthquakes with at least Mj 5.5 can be detected by monitoring atmospheric radon near the epicentre. © The Author 2016. Published by Oxford University Press.
Outerbridge, Catherine A; Marks, Stanley L; Rogers, Quinton R
2002-08-01
Plasma amino acid concentrations were measured in 36 dogs diagnosed with superficial necrolytic dermatitis (SND) via skin biopsy. The median age of the dogs was 10 years, and 27 out of 36 (75%) were male. Twenty-two out of 36 (61%) of the dogs were accounted for by six breeds; West Highland white terriers (six), Shetland sheepdogs (five), cocker spaniels (four), Scottish terriers (three), Lhasa apsos (two) and Border collies (two). The mean concentration (+/- standard deviation) was calculated for each measured plasma amino acid and compared to previously documented concentrations of plasma amino acids measured in dogs with acute and chronic hepatitis. The ratio of branched chain amino acids to aromatic amino acids in the dogs with SND was 2.6, slightly lower than that in normal dogs. The mean plasma amino acid concentrations for dogs with SND were significantly lower than for dogs with acute and chronic hepatitis. A metabolic hepatopathy in which there is increased hepatic catabolism of amino acids is hypothesized to explain the hypoaminoacidaemia seen in SND.
McKenna, D; Kadidlo, D; Sumstad, D; McCullough, J
2003-01-01
Errors and accidents, or deviations from standard operating procedures, other policy, or regulations must be documented and reviewed, with corrective actions taken to assure quality performance in a cellular therapy laboratory. Though expectations and guidance for deviation management exist, a description of the framework for the development of such a program is lacking in the literature. Here we describe our deviation management program, which uses a Microsoft Access database and Microsoft Excel to analyze deviations and notable events, facilitating quality assurance (QA) functions and ongoing process improvement. Data is stored in a Microsoft Access database with an assignment to one of six deviation type categories. Deviation events are evaluated for potential impact on patient and product, and impact scores for each are determined using a 0- 4 grading scale. An immediate investigation occurs, and corrective actions are taken to prevent future similar events from taking place. Additionally, deviation data is collectively analyzed on a quarterly basis using Microsoft Excel, to identify recurring events or developing trends. Between January 1, 2001 and December 31, 2001 over 2500 products were processed at our laboratory. During this time period, 335 deviations and notable events occurred, affecting 385 products and/or patients. Deviations within the 'technical error' category were most common (37%). Thirteen percent of deviations had a patient and/or a product impact score > or = 2, a score indicating, at a minimum, potentially affected patient outcome or moderate effect upon product quality. Real-time analysis and quarterly review of deviations using our deviation management program allows for identification and correction of deviations. Monitoring of deviation trends allows for process improvement and overall successful functioning of the QA program in the cell therapy laboratory. Our deviation management program could serve as a model for other laboratories in need of such a program.
Faraji, Hossein; Mohammadi, Ali Akbar; Akbari-Adergani, Behrouz; Vakili Saatloo, Naimeh; Lashkarboloki, Gholamreza; Mahvi, Amir Hossein
2014-12-01
Fluoride is an essential element for human health. However, excess fluoride in drinking water may cause dental and/or skeletal fluorosis. Drinking water is the main route of fluoride intake. The aim of the present study was to measure fluoride levels in human breast milk collected from two regions of Golestan Province, northern Iran with different amount of fluoride concentration of drinking water in Bandar Gaz and Nokande cities and to correlate it with fluoride concentrations in drinking water used by mothers living in these two areas. Twenty samples of water were collected from seven drinking water wells during 2012 from Bandar Gaz and Nokande in Iran during 2012. Fluoride concentration of water samples was measured using SPADNS method. Sixty breast milk samples were collected from lactating mothers of Bandar Gaz and Nokande cities. Content in breast milk was determined using standard F ion-selective electrode. Spearman's rho correlation analysis was used to assess any possible relationship between fluoride levels in breast milk and in drinking water. The means and standard deviation for F concentration in breast milk and drinking water were 0.002188±0.00026224 ppm and 0.5850±0.22542 ppm, respectively. Analysis of data showed that the variables were not normally distributed so the Spearman correlation coefficient between two variables calculated (ρ S = 0.65) and it was significant (P=0.002). Fluoride concentration in water can directly act on its concentration in breast milk. We speculate that modifying F concentration in water can affect accessibility of fluoride for infants.
FARAJI, Hossein; MOHAMMADI, Ali Akbar; AKBARI-ADERGANI, Behrouz; VAKILI SAATLOO, Naimeh; LASHKARBOLOKI, Gholamreza; MAHVI, Amir Hossein
2014-01-01
Background: Fluoride is an essential element for human health. However, excess fluoride in drinking water may cause dental and/or skeletal fluorosis. Drinking water is the main route of fluoride intake. The aim of the present study was to measure fluoride levels in human breast milk collected from two regions of Golestan Province, northern Iran with different amount of fluoride concentration of drinking water in Bandar Gaz and Nokande cities and to correlate it with fluoride concentrations in drinking water used by mothers living in these two areas. Methods: Twenty samples of water were collected from seven drinking water wells during 2012 from Bandar Gaz and Nokande in Iran during 2012. Fluoride concentration of water samples was measured using SPADNS method. Sixty breast milk samples were collected from lactating mothers of Bandar Gaz and Nokande cities. Content in breast milk was determined using standard F ion-selective electrode. Spearman’s rho correlation analysis was used to assess any possible relationship between fluoride levels in breast milk and in drinking water. Results: The means and standard deviation for F concentration in breast milk and drinking water were 0.002188±0.00026224 ppm and 0.5850±0.22542 ppm, respectively. Analysis of data showed that the variables were not normally distributed so the Spearman correlation coefficient between two variables calculated (ρS = 0.65) and it was significant (P=0.002). Conclusion: Fluoride concentration in water can directly act on its concentration in breast milk. We speculate that modifying F concentration in water can affect accessibility of fluoride for infants. PMID:26171359
Trace elemental analysis in cancer-afflicted tissues of penis and testis by PIXE technique
NASA Astrophysics Data System (ADS)
Naga Raju, G. J.; John Charles, M.; Bhuloka Reddy, S.; Sarita, P.; Seetharami Reddy, B.; Rama Lakshmi, P. V. B.; Vijayan, V.
2005-04-01
PIXE technique was employed to estimate the trace elemental concentrations in the biological samples of cancerous penis and testis. A 3 MeV proton beam was employed to excite the samples. From the present results it can be seen that the concentrations of Cl, Fe and Co are lower in the cancerous tissue of the penis when compared with those in normal tissue while the concentrations of Cu, Zn and As are relatively higher. The concentrations of K, Ca, Ti, Cr, Mn, Br, Sr and Pb are in agreement within standard deviations in both cancerous and normal tissues. In the cancerous tissue of testis, the concentrations of K, Cr and Cu are higher while the concentrations of Fe, Co and Zn are lower when compared to those in normal tissue of testis. The concentrations of Cl, Ca, Ti and Mn are in agreement in both cancerous and normal tissues of testis. The higher levels of Cu lead to the development of tumor. Our results also support the underlying hypothesis of an anticopper, antiangiogenic approach to cancer therapy. The Cu/Zn ratios of both penis and testis were higher in cancer tissues compared to that of normal.
Sitko, Rafal; Zawisza, Beata; Kowalewska, Zofia; Kocot, Karina; Polowniak, Marzena
2011-09-30
The determination of fatty acid methyl esters (FAME) in diesel fuel blends is an important aspect of production and blending process as well as quality control of distribution operations. In this study, energy-dispersive X-ray fluorescence spectrometer (EDXRF) is used for the first time for determination of FAME in biodiesel blends. The principle of the method is based on intensity difference of X-ray radiation scattered from hydrocarbons and from FAME. The experiment shows that coherent and incoherent radiation, commonly applied for evaluation of the average atomic number of the sample with light matrix, cannot be applied for FAME determination. However, the application of scattered continuous radiation gives excellent correlation between FAME concentration and intensity of scattered radiation. The best results are obtained if continuum is collected in the range of energy between 10.5 and 15.0 keV for rhodium X-ray tube, operated at 35 kV. Linear relationship between the FAME concentration and the inverse of scattered continuous radiation is obtained with the correlation coefficients of 0.999. Standard deviation of measurement is ca. 0.46% (v/v) of FAME and detection limit is 1.2% (v/v) for 600 s counting time and 50% dead-time loss using Si-PIN detector. The investigation shows that crucial issue in determination of FAME in biodiesel blends using EDXRF spectrometer is the precision of measurements resulting from the counting statistics. Therefore, much better results (0.20% (v/v) standard deviation and 0.52% (v/v) detection limit) can be expected if higher intensity of primary radiation is applied and X-ray spectrum is collected by silicon drift detector of high input count rate. For concentration of FAME from 10 to 100% (v/v), the differences between reference method (Fourier transform infrared spectrometry) and the proposed method usually do not exceed 1% (v/v) of FAME. The proposed method is fast, simple and enables FAME determination in wide range of concentration up to 100% of FAME without any sample treatment. Copyright © 2011 Elsevier B.V. All rights reserved.
Ademola, Janet Ayobami; Oyeleke, Oyebode Akanni
2017-03-20
Radon concentration in groundwater collected from the eleven Local Government Areas (LGAs) of Ibadan, Nigeria, was analyzed. Annual effective doses due to ingestion and inhalation of radon from the consumption of the water were determined. The arithmetic means (AMs) of radon concentration for the 11 LGAs varied from 2.18 to 76.75 Bq l -1 with a standard deviation of 1.57 and 70.64 Bq l -1 , respectively. The geometric means (GMs) varied from 1.67 to 49.47 Bq l -1 with geometric standard deviation of 2.22 and 3.04, respectively. About 58% of the 84 water samples examined had a higher concentration of radon than the 11.1 Bq l -1 recommended by United States Environmental Protection Agency (USEPA); the AMs of six LGAs and GMs of three LGAs were higher than the recommended value. However the AMs and GMs of all the LGAs with about 93% of the water sampled were lower than the 100 Bq l -1 recommended by the World Health Organization and EURATOM drinking water directive. The concentration of radon varied with the geological formation of the area. The AMs of the annual effective dose due to ingestion of radon in water ranged from 0.036 to 1.261 mSv y -1 , 0.071 to 2.521 mSv y -1 and 0.042 to 1.471 mSv y -1 for adult, child and infant, respectively and the GMs in the range of 0.026 to 0.813, 0.055 to 1.625 and 0.032 to 0.948 mSv y -1 , respectively. The AMs of 10 LGAs and GMs of 7 LGAs were higher than the recommended reference dose level of 0.1 mSv y -1 from the consumption of water for the duration of one year for all the three categories of people. The AMs and GMs of the annual effective dose due to inhalation of radon in drinking water ranged from 0.533 to 18.82 μSv y -1 and 0.411 to 12.13 μSv y -1 , respectively, contributing less to the overall dose.
Suspended sand transport in surf zones
NASA Astrophysics Data System (ADS)
Kobayashi, Nobuhisa; Zhao, Haoyu; Tega, Yukiko
2005-12-01
Three tests were conducted in a wave flume to investigate time-averaged suspended sediment transport processes under irregular breaking waves on equilibrium beaches consisting of fine sand. Free surface elevations were measured at ten locations for each test. Velocities and concentrations were measured in the vicinity of the bottom at 94 elevations along 17 vertical lines. The relations among the three turbulent velocity variances are found to be similar to those for the boundary layer flow. The vertical variation of the mean velocity, which causes offshore transport, is fitted by a parabolic profile fairly well. The vertical variation of the mean concentration ? is fitted by the exponential and power-form distributions equally well. The ratio between the concentration standard deviation σC and the mean ? varies little vertically. The correlation coefficient γUC between the horizontal velocity and concentration, which results in onshore transport, is of the order of 0.1 and decreases upward linearly. The offshore and onshore transport rates of suspended sediment are estimated and expressed in terms of the suspended sediment volume ? per unit area. A time-averaged numerical model is developed to predict ? as well as the mean and standard deviation of the free surface elevation and horizontal velocity. The bottom slope effect on the wave energy dissipation rate DB due to wave breaking is included in the model. The computation can be made well above the still water shoreline with no numerical difficulty. Reflected waves from the shoreline are estimated from the wave energy flux remaining at the shoreline. The numerical model is in agreement with the statistical data except that the undertow current is difficult to predict accurately. The measured turbulent velocities are found to be more related to the turbulent velocity estimated from the energy dissipation rate Df due to bottom friction. The suspended sediment volume ? expressed in terms of DB and Df can be predicted only within a factor of about 2. The roller effect represented by the roller volume flux does not necessarily improve the agreement for the three tests.
Ku-band radar threshold analysis
NASA Technical Reports Server (NTRS)
Weber, C. L.; Polydoros, A.
1979-01-01
The statistics of the CFAR threshold for the Ku-band radar was determined. Exact analytical results were developed for both the mean and standard deviations in the designated search mode. The mean value is compared to the results of a previously reported simulation. The analytical results are more optimistic than the simulation results, for which no explanation is offered. The normalized standard deviation is shown to be very sensitive to signal-to-noise ratio and very insensitive to the noise correlation present in the range gates of the designated search mode. The substantial variation in the CFAR threshold is dominant at large values of SNR where the normalized standard deviation is greater than 0.3. Whether or not this significantly affects the resulting probability of detection is a matter which deserves additional attention.
Hart, John
2011-03-01
This study describes a model for statistically analyzing follow-up numeric-based chiropractic spinal assessments for an individual patient based on his or her own baseline. Ten mastoid fossa temperature differential readings (MFTD) obtained from a chiropractic patient were used in the study. The first eight readings served as baseline and were compared to post-adjustment readings. One of the two post-adjustment MFTD readings fell outside two standard deviations of the baseline mean and therefore theoretically represents improvement according to pattern analysis theory. This study showed how standard deviation analysis may be used to identify future outliers for an individual patient based on his or her own baseline data. Copyright © 2011 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.
1980-03-14
failure Sigmar (Or) in line 50, the standard deviation of the relative error of the weights Sigmap (o) in line 60, the standard deviation of the phase...200, the weight structures in the x and y coordinates Q in line 210, the probability of element failure Sigmar (Or) in line 220, the standard...NUMBER OF ELEMENTS =u;2*H 120 PRINT "Pr’obability of elemenit failure al;O 130 PRINT "Standard dtvi&t ion’ oe r.1&tive ýrror of wl; Sigmar 14 0 PRINT
Takarabe, S; Yabuuchi, H; Morishita, J
2012-06-01
To investigate the usefulness of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high- density mammary glands region to a whole mammary glands region as features for classification of mammograms into four categories based on the ACR BI-RADS breast composition. We used 36 digital mediolateral oblique view mammograms (18 patients) approved by our IRB. These images were classified into the four categories of breast compositions by an experienced breast radiologist and the results of the classification were regarded as a gold standard. First, a whole mammary region in a breast was divided into two regions such as a high-density mammary glands region and a low/iso-density mammary glands region by using a threshold value that was obtained from the pixel values corresponding to a pectoral muscle region. Then the percentage of a high-density mammary glands region to a whole mammary glands region was calculated. In addition, as a new method, the standard deviation of pixel values in a whole mammary glands region was calculated as an index based on the intermingling of mammary glands and fats. Finally, all mammograms were classified by using the combination of the percentage of a high-density mammary glands region and the standard deviation of each image. The agreement rates of the classification between our proposed method and gold standard was 86% (31/36). This result signified that our method has the potential to classify mammograms. The combination of the standard deviation of pixel values in a whole mammary glands region and the percentage of a high-density mammary glands region to a whole mammary glands region was available as features to classify mammograms based on the ACR BI- RADS breast composition. © 2012 American Association of Physicists in Medicine.
Cui, Dong; Han, GuangWei; Shang, YongGang; Mu, LiJun; Long, QingZhi; Du, YueFeng
2015-01-01
Prostatitis is a common disease in urology departments. Prostatic zinc accumulation is connected with the secretory function of the prostate, and zinc concentrations present in prostatic diseases differ greatly from the normal level. Studies have investigated the effect of chronic prostatitis on zinc concentration of prostatic fluid and seminal plasma, but have shown inconsistent results. Hence, we performed a systematic literature review and meta-analysis to assess the effect of chronic prostatitis on the zinc concentration of prostatic fluid and seminal plasma. Systematic literature searches were conducted with PubMed, Embase, Science Direct/Elsevier, CNKI and the Cochrane Library up to March 2015 for case-control studies that involved the relationship between chronic prostatitis and zinc concentration of prostatic fluid and seminal plasma. Meta-analysis was performed with Review Manager and Stata software. Standard mean differences (SMDs) of zinc concentration were identified with 95% confidence intervals (95% CIs) in a random- or fixed-effects model. Our results illustrated that the zinc concentrations in prostatic fluid and seminal plasma from chronic prostatitis patients were significantly lower than normal controls (SMD [95% CI] -246.71 [-347.97, -145.44], -20.74 [-35.11, -6.37], respectively). The sample size of each study was relatively small, and a total of 731 chronic prostatitis patients and 574 normal controls were investigated in all fourteen studies. Several studies related to the subject were excluded due to lack of control data or means and standard deviations. The present study illustrates that there was a significant negative effect of chronic prostatitis on zinc concentrations of prostatic fluid and seminal plasma. Further studies with larger sample sizes are needed to better illuminate the negative impact of chronic prostatitis on zinc concentrations.
Bian, Xiao-Peng; Yang, Tao; Lin, An-Jun; Jiang, Shao-Yong
2015-01-01
We have developed a technique for the rapid, precise and accurate determination of sulfur isotopes (δ(34)S) by MC-ICP-MS applicable to a range of sulfur-bearing solutions of different sulfur content. The 10 ppm Alfa-S solution (ammonium sulfate solution, working standard of the lab of the authors) was used to bracket other Alfa-S solutions of different concentrations and the measured δ(34)SV-CDT values of Alfa-S solutions deviate from the reference value to varying degrees (concentration effect). The stability of concentration effect has been verified and a correction curve has been constructed based on Alfa-S solutions to correct measured δ(34)SV-CDT values. The curve has been applied to AS solutions (dissolved ammonium sulfate from the lab of the authors) and pore water samples successfully, validating the reliability of our analytical method. This method also enables us to measure the sulfur concentration simultaneously when analyzing the sulfur isotope composition. There is a strong linear correlation (R(2)>0.999) between the sulfur concentrations and the intensity ratios of samples and the standard. We have constructed a regression curve based on Alfa-S solutions and this curve has been successfully used to determine sulfur concentrations of AS solutions and pore water samples. The analytical technique presented here enable rapid, precise and accurate S isotope measurement for a wide range of sulfur-bearing solutions - in particular for pore water samples with complex matrix and varying sulfur concentrations. Also, simultaneous measurement of sulfur concentrations is available. Copyright © 2014 Elsevier B.V. All rights reserved.
40 CFR 63.7951 - What reports must I submit and when?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the information in § 63.10(d)(5)(i). (5) If there were no deviations from any emissions limitations... that there were no deviations from the emissions limitations, work practice standards, or operation and...) For each deviation from an emissions limitation (including an operating limit) that occurs at an...
Fırat, Merve; Bodur, Süleyman; Tışlı, Büşra; Özlü, Cansu; Chormey, Dotse Selali; Turak, Fatma; Bakırdere, Sezgin
2018-06-12
In this study, a switchable solvent was used to preconcentrate trace amounts of Cd from aqueous solution for its determination by flame atomic absorption spectrometry (FAAS). Protonation of N,N-dimethylbenzylamine by dry ice (solid CO 2 ) made it water soluble, and addition of sodium hydroxide converted it back to its original nonionic state for phase separation and subsequent extraction of Cd. A slotted quartz tube (SQT) was attached to the flame burner head to increase the residence time of Cd atoms in the light path. Under the optimum conditions, limits of detection and quantification were determined as 0.7 and 2.6 μg L -1 , respectively. Low relative standard deviations calculated from seven replicate measurements of the lowest concentration indicated high precision. Accuracy of the developed method was checked by using a standard reference material (SRM 1633c). Spiked recovery tests were also performed on lake water and wastewater samples at different concentrations to check the applicability of the developed method, and the results obtained (90-103%) established high recovery.
Spark ablation-inductively coupled plasma spectrometry for analysis of geologic materials
Golightly, D.W.; Montaser, A.; Smith, B.L.; Dorrzapf, A.F.
1989-01-01
Spark ablation-inductively coupled plasma (SA-ICP) spectrometry is applied to the measurement of hafnium-zirconium ratios in zircons and to the determination of cerium, cobalt, iron, lead, nickel and phosphorus in ferromanganese nodules. Six operating parameters used for the high-voltage spark and argon-ICP combination are established by sequential simplex optimization of both signal-to-background ratio and signal-to-noise ratio. The time-dependences of the atomic emission signals of analytes and matrix elements ablated from a finely pulverized sample embedded in a pressed disk of copper demonstrate selective sampling by the spark. Concentration ratios of hafnium to zirconium in zircons are measured with a precision of 4% (relative standard deviation, RSD). For ferromanganese nodules, spectral measurements based on intensity ratios of analyte line to the Mn(II) 257.610 nm line provide precisions of analysis in the range from 7 to 14% RSD. The accuracy of analysis depends on use of standard additions of the reference material USGS Nod P-1, and an independent measurement of the Mn concentration. ?? 1989.
Mohammad, Rosmawani; Ahmad, Musa; Heng, Lee Yook
2013-01-01
Chili hotness is very much dependent on the concentration of capsaicin present in the chili fruit. A new biosensor based on a horseradish peroxidase enzyme-capsaicin reaction mediated by ferrocene has been successfully developed for the amperometric determination of chili hotness. The amperometric biosensor is fabricated based on a single-step immobilization of both ferrocene and horseradish peroxidase in a photocurable hydrogel membrane, poly(2-hydroxyethyl methacrylate). With mediation by ferrocene, the biosensor could measure capsaicin concentrations at a potential 0.22 V (vs. Ag/AgCl), which prevented potential interference from other electroactive species in the sample. Thus a good selectivity towards capsaicin was demonstrated. The linear response range of the biosensor towards capsaicin was from 2.5–99.0 μM with detection limit of 1.94 μM. A good relative standard deviation (RSD) for reproducibility of 6.4%–9.9% was obtained. The capsaicin biosensor demonstrated long-term stability for up to seven months. The performance of the biosensor has been validated using a standard method for the analysis of capsaicin based on HPLC. PMID:23921830
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gupta, N; DiCostanzo, D; Fullenkamp, M
2015-06-15
Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations weremore » computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.« less
Yoon, Donhee; Lee, Dongkun; Lee, Jong-Hyeon; Cha, Sangwon; Oh, Han Bin
2015-01-30
Quantifying polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) with a conventional crystalline matrix generally suffers from poor sample-to-sample or shot-to-shot reproducibility. An ionic-liquid matrix has been demonstrated to mitigate these reproducibility issues by providing a homogeneous sample surface, which is useful for quantifying polymers. In the present study, we evaluated the use of an ionic liquid matrix, i.e., 1-methylimidazolium α-cyano-4-hydroxycinnamate (1-MeIm-CHCA), to quantify polyhexamethylene guanidine (PHMG) samples that impose a critical health hazard when inhaled in the form of droplets. MALDI-TOF mass spectra were acquired for PHMG oligomers using a variety of ionic-liquid matrices including 1-MeIm-CHCA. Calibration curves were constructed by plotting the sum of the PHMG oligomer peak areas versus PHMG sample concentration with a variety of peptide internal standards. Compared with the conventional crystalline matrix, the 1-MeIm-CHCA ionic-liquid matrix had much better reproducibility (lower standard deviations). Furthermore, by using an internal peptide standard, good linear calibration plots could be obtained over a range of PMHG concentrations of at least 4 orders of magnitude. This study successfully demonstrated that PHMG samples can be quantitatively characterized by MALDI-TOFMS with an ionic-liquid matrix and an internal standard. Copyright © 2014 John Wiley & Sons, Ltd.
Peng, S; Shan, X Q; Zheng, Y; Jin, L Z; Xu, W B
1991-12-06
A rapid method is described for the determination of dietary cadmium-induced metallothioneins (MTs) in rabbit kidneys by anion-exchange high-performance liquid chromatography. Rabbit kidney MT-I and MT-II were eluted at ca. 15.0 and 18.8 min, respectively, from a DEAE-5PW anion-exchange column with a Tris-HCl buffer (0.01-0.25 M, pH 8.6) and detected by ultraviolet absorbance at 254 nm. A standard calibration curve was constructed using purified standard MT isoforms, which demonstrated an excellent linear correlation between UV absorbance peak heights and the amounts of MT isoforms. Feeding a dose of cadmium for some days resulted in an increase in MT concentrations in rabbit kidneys, but not in the livers. The cadmium concentrations in MT-I and MT-II elutions were determined by graphite furnace atomic absorption spectrometry. MT-I and MT-II showed some differences associated with the oral intake of cadmium. Dietary cadmium also caused zinc to accumulate in kidneys to some extent. The effects of dietary oleic acid on the synthesis of MTs were also studied. Based on the method of standard additions, the recovery of MTs exceeded 93% and replicated injection of samples yielded a relative standard deviation of 2.4% at an MT level of 280 micrograms/g.
Buckley, Jessie P; Quirós-Alcalá, Lesliam; Teitelbaum, Susan L; Calafat, Antonia M; Wolff, Mary S; Engel, Stephanie M
2018-06-01
Prenatal environmental phenol and phthalate exposures may alter immune or inflammatory responses leading to respiratory and allergic disease. We estimated associations of prenatal environmental phenol and phthalate biomarkers with respiratory and allergic outcomes among children in the Mount Sinai Children's Environmental Health Study. We quantified urinary biomarkers of benzophenone-3, bisphenol A, paradichlorobenzene (as 2,5-dichlorophenol), triclosan, and 10 phthalate metabolites in third trimester maternal samples and assessed asthma, wheeze, and atopic skin conditions via parent questionnaires at ages 6 and 7 years (n = 164 children with 240 observations). We used logistic regression to estimate covariate-adjusted odds ratios (ORs) and 95% confidence intervals (CIs) per standard deviation difference in natural log biomarker concentrations and examined effect measure modification by child's sex. Associations of prenatal 2,5-dichlorophenol (all outcomes) and bisphenol A (asthma outcomes) were modified by child's sex, with increased odds of outcomes among boys but not girls. Among boys, ORs for asthma diagnosis per standard deviation difference in biomarker concentration were 3.00 (95% CI: 1.36, 6.59) for 2,5-dichlorophenol and 3.04 (95% CI: 1.38, 6.68) for bisphenol A. Wheeze in the past 12 months was inversely associated with low molecular weight phthalate metabolites among girls only (OR: 0.27, 95% CI: 0.13, 0.59) and with benzophenone-3 among all children (OR: 0.65, 95% CI: 0.44, 0.96). Prenatal bisphenol A and paradichlorobenzene exposures were associated with pediatric respiratory outcomes among boys. Future studies may shed light on biological mechanisms and potential sexually-dimorphic effects of select phenols and phthalates on respiratory disease development. Copyright © 2018 Elsevier Ltd. All rights reserved.
de Toffoli, Ana L; da Mata, Kamilla; Bisinoti, Márcia C; Moreira, Altair B
2015-01-01
A method for the identification and quantification of pesticide residues in water, soil, and sediment samples has been developed, validated, and applied for the analysis of real samples. The specificity was determined by the retention time and the confirmation and quantification of analyte ions. Linearity was demonstrated over the concentration range of 20 to 120 µg L(-1), and the correlation coefficients varied between 0.979 and 0.996, depending on the analytes. The recovery rates for all analytes in the studied matrix were between 86% and 112%. The intermediate precision and repeatability were determined at three concentration levels (40, 80, and 120 µg L(-1)), with the relative standard deviation for the intermediate precision between 1% and 5.3% and the repeatability varying between 2% and 13.4% for individual analytes. The limits of detection and quantification for fipronil, fipronil sulfide, fipronil-sulfone, and fipronil-desulfinyl were 6.2, 3.0, 6.6, and 4.0 ng L(-1) and 20.4, 9.0, 21.6, and 13.0 ng L(-1), respectively. The method developed was used in water, soil, and sediment samples containing 2.1 mg L(-1) and 1.2% and 5.3% of carbon, respectively. The recovery of pesticides in the environmental matrices varied from 88.26 to 109.63% for the lowest fortification level (40 and 100 µg kg(-1)), from 91.17 to 110.18% for the intermediate level (80 and 200 µg kg(-1)), and from 89.09 to 109.82% for the highest fortification level (120 and 300 µg kg(-1)). The relative standard deviation for the recovery of pesticides was under 15%.
Petersen, Nanna; Stocks, Stuart; Gernaey, Krist V
2008-05-01
The main purpose of this article is to demonstrate that principal component analysis (PCA) and partial least squares regression (PLSR) can be used to extract information from particle size distribution data and predict rheological properties. Samples from commercially relevant Aspergillus oryzae fermentations conducted in 550 L pilot scale tanks were characterized with respect to particle size distribution, biomass concentration, and rheological properties. The rheological properties were described using the Herschel-Bulkley model. Estimation of all three parameters in the Herschel-Bulkley model (yield stress (tau(y)), consistency index (K), and flow behavior index (n)) resulted in a large standard deviation of the parameter estimates. The flow behavior index was not found to be correlated with any of the other measured variables and previous studies have suggested a constant value of the flow behavior index in filamentous fermentations. It was therefore chosen to fix this parameter to the average value thereby decreasing the standard deviation of the estimates of the remaining rheological parameters significantly. Using a PLSR model, a reasonable prediction of apparent viscosity (micro(app)), yield stress (tau(y)), and consistency index (K), could be made from the size distributions, biomass concentration, and process information. This provides a predictive method with a high predictive power for the rheology of fermentation broth, and with the advantages over previous models that tau(y) and K can be predicted as well as micro(app). Validation on an independent test set yielded a root mean square error of 1.21 Pa for tau(y), 0.209 Pa s(n) for K, and 0.0288 Pa s for micro(app), corresponding to R(2) = 0.95, R(2) = 0.94, and R(2) = 0.95 respectively. Copyright 2007 Wiley Periodicals, Inc.
Schmidt, Alice; Aurich, Jörg; Möstl, Erich; Müller, Jürgen; Aurich, Christine
2010-09-01
Based on cortisol release, a variety of situations to which domestic horses are exposed have been classified as stressors but studies on the stress during equestrian training are limited. In the present study, Warmblood stallions (n=9) and mares (n=7) were followed through a 9 respective 12-week initial training program in order to determine potentially stressful training steps. Salivary cortisol concentrations, beat-to-beat (RR) interval and heart rate variability (HRV) were determined. The HRV variables standard deviation of the RR interval (SDRR), RMSSD (root mean square of successive RR differences) and the geometric means standard deviation 1 (SD1) and 2 (SD2) were calculated. Nearly each training unit was associated with an increase in salivary cortisol concentrations (p<0.01). Cortisol release varied between training units and occasionally was more pronounced in mares than in stallions (p<0.05). The RR interval decreased slightly in response to lunging before mounting of the rider. A pronounced decrease occurred when the rider was mounting, but before the horse showed physical activity (p<0.001). The HRV variables SDRR, RMSSD and SD1 decreased in response to training and lowest values were reached during mounting of a rider (p<0.001). Thereafter RR interval and HRV variables increased again. In contrast, SD2 increased with the beginning of lunging (p<0.05) and no changes in response to mounting were detectable. In conclusion, initial training is a stressor for horses. The most pronounced reaction occurred in response to mounting by a rider, a situation resembling a potentially lethal threat under natural conditions. Copyright (c) 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ren, Yan; Zheng, Shuwen; Wei, Wei; Wu, Bingui; Zhang, Hongsheng; Cai, Xuhui; Song, Yu
2018-02-01
We analyzed the structure and evolution of turbulent transfer and the wind profile in the atmospheric boundary layer in relation to aerosol concentrations during an episode of heavy haze pollution from 6 December 2016 to 9 January 2017. The turbulence data were recorded at Peking University's atmospheric science and environment observation station. The results showed a negative correlation between the wind speed and the PM2.5 concentration. The turbulence kinetic energy was large and showed obvious diurnal variations during unpolluted (clean) weather, but was small during episodes of heavy haze pollution. Under both clean and heavy haze conditions, the relation between the non-dimensional wind components and the stability parameter z/ L followed a 1/3 power law, but the normalized standard deviations of the wind speed were smaller during heavy pollution events than during clean periods under near-neutral conditions. Under unstable conditions, the normalized standard deviation of the potential temperature σ θ /| θ *| was related to z/ L, roughly following a -1/3 power law, and the ratio during pollution days was greater than that during clean days. The three-dimensional turbulence energy spectra satisfied a -2/3 power exponent rate in the high-frequency band. In the low-frequency band, the wind velocity spectrum curve was related to the stability parameters under clear conditions, but was not related to atmospheric stratification under polluted conditions. In the dissipation stage of the heavy pollution episode, the horizontal wind speed first started to increase at high altitudes and then gradually decreased at lower altitudes. The strong upward motion during this stage was an important dynamic factor in the dissipation of the heavy haze.
A fiberoptic reflection oximeter.
Landsman, M L; Knop, N; Kwant, G; Mook, G A; Zijlstra, W G
1978-03-20
A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.
Oostingh, Elsje C; Steegers-Theunissen, Régine P M; de Vries, Jeanne H M; Laven, Joop S E; Koster, Maria P H
2017-04-01
To study associations between periconceptional dietary patterns and semen quality parameters. Prospective periconception cohort study. Tertiary hospital. One hundred and twenty-nine male partners of pregnant women who participated in the Rotterdam Periconception Cohort (Predict study). None. Semen quality parameters-ejaculate volume, sperm concentration, total sperm count, progressive motility, immotile sperm, and total motile sperm count (TMSC). Men included in our study were on average 35 (±6 standard deviation) years old and had a body mass index of 26.4 ± 4 kg/m 2 . Two dietary patterns were identified using principle component analysis, which were labeled as "healthy" and "unhealthy." An increase of one factor score (stated as β) represented an increase of 1 standard deviation. Sperm concentration (β = 0.278; 95% CI, 0.112-0.444), total sperm count (β = 1.369; 95% CI, 0.244-2.495), progressive motility (β = 4.305; 95% CI, 0.675-7.936), and TMSC (β = 0.319; 95% CI, 0.113-0.526) were all positively associated with a strong adherence to the healthy dietary pattern. Subgroup analysis showed that these associations were mainly present in men with a TMSC <10 million spermatozoa. Although there was a trend toward a diminution in semen quality, we found no statistically significant associations with strong adherence to the unhealthy dietary pattern. The positive associations between strong adherence to a healthy dietary pattern and semen parameters in men with poor semen quality support the importance of preconceptional tailored nutritional counseling and coaching of couples who are trying to conceive. Copyright © 2017 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Selenium status in pregnancy influences children's cognitive function at 1.5 years of age.
Skröder, Helena M; Hamadani, Jena D; Tofail, Fahmida; Persson, Lars Åke; Vahter, Marie E; Kippler, Maria J
2015-10-01
Selenium deficiency has been shown to affect the neurological development in animals, but human research in this area is scarce. We aimed to assess the impact of selenium status during pregnancy on child development at 1.5 years of age. This prospective cohort study was nested into a food and micronutrient supplementation trial (MINIMat) conducted in rural Bangladesh. Using inductively coupled plasma mass spectrometry, we measured selenium concentrations in erythrocyte fraction of blood collected from 750 mothers at gestational week 30, and calculated μg per g hemoglobin. A revised version of Bayley Scales of Infant Development was used to assess children's mental and psychomotor development. A Bangladeshi version of MacArthur's Communicative Development Inventory was used to assess language comprehension and expression. Linear regression analyses adjusted for multiple covariates were used to assess the associations. Maternal erythrocyte selenium concentrations varied considerably, from 0.19 to 0.87 μg/g hemoglobin (median 0.46 μg/g hemoglobin), and were associated with developmental measures. An increase in erythrocyte selenium by 0.50 μg/g hemoglobin was associated with an increase in children's language comprehension by 3.7 points (0.5 standard deviations; 95% confidence interval: 0.40, 7.1; p = 0.028). The same increase in erythrocyte selenium corresponded to an increase in the girls' psychomotor development by 12 points (0.9 standard deviation; 95% confidence interval: 4.3, 19; p = 0.002), but much less in boys. Low prenatal selenium status seems to be disadvantageous for children's psychomotor and language development. Further studies are needed to elucidate the underlying mechanisms of these effects. Copyright © 2014 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aaboud, M.; Aad, G.; Abbott, B.
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
Aaboud, M.; Aad, G.; Abbott, B.; ...
2018-04-09
Here, a search for the associated production of the Higgs boson with a top quark pair (more » $$t\\bar{t}$$H) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb -1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy $$\\sqrt{s}$$ = 13 TeV at the Large Hadron Collider. Higgs boson decays to WW*, ττ, and ZZ* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the $$t\\bar{t}$$H production cross section is σ($$t\\bar{t}$$H) = $${790}_{-210}^{+230}$$ fb, in agreement with the Standard Model prediction of $${507}_{-50}^{+35}$$ fb. The combination of this result with other $$t\\bar{t}$$H searches from the ATLAS experiment using the Higgs boson decay modes to $$b\\bar{b}$$, γγ and ZZ* → 4ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the $$t\\bar{t}$$H production mode.« less
NASA Astrophysics Data System (ADS)
Aaboud, M.; Aad, G.; Abbott, B.; Abdinov, O.; Abeloos, B.; Abidi, S. H.; Abouzeid, O. S.; Abraham, N. L.; Abramowicz, H.; Abreu, H.; Abulaiti, Y.; Acharya, B. S.; Adachi, S.; Adamczyk, L.; Adelman, J.; Adersberger, M.; Adye, T.; Affolder, A. A.; Afik, Y.; Agheorghiesei, C.; Aguilar-Saavedra, J. A.; Ahlen, S. P.; Ahmadov, F.; Aielli, G.; Akatsuka, S.; Åkesson, T. P. A.; Akilli, E.; Akimov, A. V.; Alberghi, G. L.; Albert, J.; Albicocco, P.; Alconada Verzini, M. J.; Alderweireldt, S. C.; Aleksa, M.; Aleksandrov, I. N.; Alexa, C.; Alexander, G.; Alexopoulos, T.; Alhroob, M.; Ali, B.; Aliev, M.; Alimonti, G.; Alison, J.; Alkire, S. P.; Allaire, C.; Allbrooke, B. M. M.; Allen, B. W.; Allport, P. P.; Aloisio, A.; Alonso, A.; Alonso, F.; Alpigiani, C.; Alshehri, A. A.; Alstaty, M. I.; Alvarez Gonzalez, B.; Álvarez Piqueras, D.; Alviggi, M. G.; Amadio, B. T.; Amaral Coutinho, Y.; Ambroz, L.; Amelung, C.; Amidei, D.; Amor Dos Santos, S. P.; Amoroso, S.; Anastopoulos, C.; Ancu, L. S.; Andari, N.; Andeen, T.; Anders, C. F.; Anders, J. K.; Anderson, K. J.; Andreazza, A.; Andrei, V.; Angelidakis, S.; Angelozzi, I.; Angerami, A.; Anisenkov, A. V.; Annovi, A.; Antel, C.; Antonelli, M.; Antonov, A.; Antrim, D. J.; Anulli, F.; Aoki, M.; Aperio Bella, L.; Arabidze, G.; Arai, Y.; Araque, J. P.; Araujo Ferraz, V.; Arce, A. T. H.; Ardell, R. E.; Arduh, F. A.; Arguin, J.-F.; Argyropoulos, S.; Armbruster, A. J.; Armitage, L. J.; Arnaez, O.; Arnold, H.; Arratia, M.; Arslan, O.; Artamonov, A.; Artoni, G.; Artz, S.; Asai, S.; Asbah, N.; Ashkenazi, A.; Asquith, L.; Assamagan, K.; Astalos, R.; Atkin, R. J.; Atkinson, M.; Atlay, N. B.; Augsten, K.; Avolio, G.; Avramidou, R.; Axen, B.; Ayoub, M. K.; Azuelos, G.; Baas, A. E.; Baca, M. J.; Bachacou, H.; Bachas, K.; Backes, M.; Bagnaia, P.; Bahmani, M.; Bahrasemani, H.; Baines, J. T.; Bajic, M.; Baker, O. K.; Bakker, P. J.; Bakshi Gupta, D.; Baldin, E. M.; Balek, P.; Balli, F.; Balunas, W. K.; Banas, E.; Bandyopadhyay, A.; Banerjee, Sw.; Bannoura, A. A. E.; Barak, L.; Barberio, E. L.; Barberis, D.; Barbero, M.; Barillari, T.; Barisits, M.-S.; Barkeloo, J. T.; Barklow, T.; Barlow, N.; Barnea, R.; Barnes, S. L.; Barnett, B. M.; Barnett, R. M.; Barnovska-Blenessy, Z.; Baroncelli, A.; Barone, G.; Barr, A. J.; Barranco Navarro, L.; Barreiro, F.; Barreiro Guimarães da Costa, J.; Bartoldus, R.; Barton, A. E.; Bartos, P.; Basalaev, A.; Bassalat, A.; Bates, R. L.; Batista, S. J.; Batley, J. R.; Battaglia, M.; Bauce, M.; Bauer, F.; Bauer, K. T.; Bawa, H. S.; Beacham, J. B.; Beattie, M. D.; Beau, T.; Beauchemin, P. H.; Bechtle, P.; Beck, H. P.; Beck, H. C.; Becker, K.; Becker, M.; Becot, C.; Beddall, A. J.; Beddall, A.; Bednyakov, V. A.; Bedognetti, M.; Bee, C. P.; Beermann, T. A.; Begalli, M.; Begel, M.; Behera, A.; Behr, J. K.; Bell, A. S.; Bella, G.; Bellagamba, L.; Bellerive, A.; Bellomo, M.; Belotskiy, K.; Belyaev, N. L.; Benary, O.; Benchekroun, D.; Bender, M.; Benekos, N.; Benhammou, Y.; Benhar Noccioli, E.; Benitez, J.; Benjamin, D. P.; Benoit, M.; Bensinger, J. R.; Bentvelsen, S.; Beresford, L.; Beretta, M.; Berge, D.; Bergeaas Kuutmann, E.; Berger, N.; Bergsten, L. J.; Beringer, J.; Berlendis, S.; Bernard, N. R.; Bernardi, G.; Bernius, C.; Bernlochner, F. U.; Berry, T.; Berta, P.; Bertella, C.; Bertoli, G.; Bertram, I. A.; Bertsche, C.; Besjes, G. J.; Bessidskaia Bylund, O.; Bessner, M.; Besson, N.; Bethani, A.; Bethke, S.; Betti, A.; Bevan, A. J.; Beyer, J.; Bianchi, R. M.; Biebel, O.; Biedermann, D.; Bielski, R.; Bierwagen, K.; Biesuz, N. V.; Biglietti, M.; Billoud, T. R. V.; Bindi, M.; Bingul, A.; Bini, C.; Biondi, S.; Bisanz, T.; Bittrich, C.; Bjergaard, D. M.; Black, J. E.; Black, K. M.; Blair, R. E.; Blazek, T.; Bloch, I.; Blocker, C.; Blue, A.; Blumenschein, U.; Blunier, Dr.; Bobbink, G. J.; Bobrovnikov, V. S.; Bocchetta, S. S.; Bocci, A.; Bock, C.; Boerner, D.; Bogavac, D.; Bogdanchikov, A. G.; Bohm, C.; Boisvert, V.; Bokan, P.; Bold, T.; Boldyrev, A. S.; Bolz, A. E.; Bomben, M.; Bona, M.; Bonilla, J. S.; Boonekamp, M.; Borisov, A.; Borissov, G.; Bortfeldt, J.; Bortoletto, D.; Bortolotto, V.; Boscherini, D.; Bosman, M.; Bossio Sola, J. D.; Boudreau, J.; Bouhova-Thacker, E. V.; Boumediene, D.; Bourdarios, C.; Boutle, S. K.; Boveia, A.; Boyd, J.; Boyko, I. R.; Bozson, A. J.; Bracinik, J.; Brandt, A.; Brandt, G.; Brandt, O.; Braren, F.; Bratzler, U.; Brau, B.; Brau, J. E.; Breaden Madden, W. D.; Brendlinger, K.; Brennan, A. J.; Brenner, L.; Brenner, R.; Bressler, S.; Briglin, D. L.; Bristow, T. M.; Britton, D.; Britzger, D.; Brock, I.; Brock, R.; Brooijmans, G.; Brooks, T.; Brooks, W. K.; Brost, E.; Broughton, J. H.; Bruckman de Renstrom, P. A.; Bruncko, D.; Bruni, A.; Bruni, G.; Bruni, L. S.; Bruno, S.; Brunt, Bh; Bruschi, M.; Bruscino, N.; Bryant, P.; Bryngemark, L.; Buanes, T.; Buat, Q.; Buchholz, P.; Buckley, A. G.; Budagov, I. A.; Buehrer, F.; Bugge, M. K.; Bulekov, O.; Bullock, D.; Burch, T. J.; Burdin, S.; Burgard, C. D.; Burger, A. M.; Burghgrave, B.; Burka, K.; Burke, S.; Burmeister, I.; Burr, J. T. P.; Büscher, D.; Büscher, V.; Buschmann, E.; Bussey, P.; Butler, J. M.; Buttar, C. M.; Butterworth, J. M.; Butti, P.; Buttinger, W.; Buzatu, A.; Buzykaev, A. R.; Cabras, G.; Cabrera Urbán, S.; Caforio, D.; Cai, H.; Cairo, V. M. M.; Cakir, O.; Calace, N.; Calafiura, P.; Calandri, A.; Calderini, G.; Calfayan, P.; Callea, G.; Caloba, L. P.; Calvente Lopez, S.; Calvet, D.; Calvet, S.; Calvet, T. P.; Camacho Toro, R.; Camarda, S.; Camarri, P.; Cameron, D.; Caminal Armadans, R.; Camincher, C.; Campana, S.; Campanelli, M.; Camplani, A.; Campoverde, A.; Canale, V.; Cano Bret, M.; Cantero, J.; Cao, T.; Capeans Garrido, M. D. M.; Caprini, I.; Caprini, M.; Capua, M.; Carbone, R. M.; Cardarelli, R.; Cardillo, F.; Carli, I.; Carli, T.; Carlino, G.; Carlson, B. T.; Carminati, L.; Carney, R. M. D.; Caron, S.; Carquin, E.; Carrá, S.; Carrillo-Montoya, G. D.; Casadei, D.; Casado, M. P.; Casha, A. F.; Casolino, M.; Casper, D. W.; Castelijn, R.; Castillo Gimenez, V.; Castro, N. F.; Catinaccio, A.; Catmore, J. R.; Cattai, A.; Caudron, J.; Cavaliere, V.; Cavallaro, E.; Cavalli, D.; Cavalli-Sforza, M.; Cavasinni, V.; Celebi, E.; Ceradini, F.; Cerda Alberich, L.; Cerqueira, A. S.; Cerri, A.; Cerrito, L.; Cerutti, F.; Cervelli, A.; Cetin, S. A.; Chafaq, A.; Chakraborty, D.; Chan, S. K.; Chan, W. S.; Chan, Y. L.; Chang, P.; Chapman, J. D.; Charlton, D. G.; Chau, C. C.; Chavez Barajas, C. A.; Che, S.; Chegwidden, A.; Chekanov, S.; Chekulaev, S. V.; Chelkov, G. A.; Chelstowska, M. A.; Chen, C.; Chen, C.; Chen, H.; Chen, J.; Chen, J.; Chen, S.; Chen, S.; Chen, X.; Chen, Y.; Cheng, H. C.; Cheng, H. J.; Cheplakov, A.; Cheremushkina, E.; Cherkaoui El Moursli, R.; Cheu, E.; Cheung, K.; Chevalier, L.; Chiarella, V.; Chiarelli, G.; Chiodini, G.; Chisholm, A. S.; Chitan, A.; Chiu, Y. H.; Chizhov, M. V.; Choi, K.; Chomont, A. R.; Chouridou, S.; Chow, Y. S.; Christodoulou, V.; Chu, M. C.; Chudoba, J.; Chuinard, A. J.; Chwastowski, J. J.; Chytka, L.; Cinca, D.; Cindro, V.; Cioarǎ, I. A.; Ciocio, A.; Cirotto, F.; Citron, Z. H.; Citterio, M.; Clark, A.; Clark, M. R.; Clark, P. J.; Clarke, R. N.; Clement, C.; Coadou, Y.; Cobal, M.; Coccaro, A.; Cochran, J.; Colasurdo, L.; Cole, B.; Colijn, A. P.; Collot, J.; Conde Muiño, P.; Coniavitis, E.; Connell, S. H.; Connelly, I. A.; Constantinescu, S.; Conti, G.; Conventi, F.; Cooper-Sarkar, A. M.; Cormier, F.; Cormier, K. J. R.; Corradi, M.; Corrigan, E. E.; Corriveau, F.; Cortes-Gonzalez, A.; Costa, M. J.; Costanzo, D.; Cottin, G.; Cowan, G.; Cox, B. E.; Cranmer, K.; Crawley, S. J.; Creager, R. A.; Cree, G.; Crépé-Renaudin, S.; Crescioli, F.; Cristinziani, M.; Croft, V.; Crosetti, G.; Cueto, A.; Cuhadar Donszelmann, T.; Cukierman, A. R.; Cummings, J.; Curatolo, M.; Cúth, J.; Czekierda, S.; Czodrowski, P.; D'Amen, G.; D'Auria, S.; D'Eramo, L.; D'Onofrio, M.; da Cunha Sargedas de Sousa, M. J.; da Via, C.; Dabrowski, W.; Dado, T.; Dahbi, S.; Dai, T.; Dale, O.; Dallaire, F.; Dallapiccola, C.; Dam, M.; Dandoy, J. R.; Daneri, M. F.; Dang, N. P.; Dann, N. S.; Danninger, M.; Dano Hoffmann, M.; Dao, V.; Darbo, G.; Darmora, S.; Dattagupta, A.; Daubney, T.; Davey, W.; David, C.; Davidek, T.; Davis, D. R.; Davison, P.; Dawe, E.; Dawson, I.; de, K.; de Asmundis, R.; de Benedetti, A.; de Castro, S.; de Cecco, S.; de Groot, N.; de Jong, P.; de la Torre, H.; de Lorenzi, F.; de Maria, A.; de Pedis, D.; de Salvo, A.; de Sanctis, U.; de Santo, A.; de Vasconcelos Corga, K.; de Vivie de Regie, J. B.; Debenedetti, C.; Dedovich, D. V.; Dehghanian, N.; Deigaard, I.; Del Gaudio, M.; Del Peso, J.; Delgove, D.; Deliot, F.; Delitzsch, C. M.; Dell'Acqua, A.; Dell'Asta, L.; Della Pietra, M.; Della Volpe, D.; Delmastro, M.; Delporte, C.; Delsart, P. A.; Demarco, D. A.; Demers, S.; Demichev, M.; Denisov, S. P.; Denysiuk, D.; Derendarz, D.; Derkaoui, J. E.; Derue, F.; Dervan, P.; Desch, K.; Deterre, C.; Dette, K.; Devesa, M. R.; Deviveiros, P. O.; Dewhurst, A.; Dhaliwal, S.; di Bello, F. A.; di Ciaccio, A.; di Ciaccio, L.; di Clemente, W. K.; di Donato, C.; di Girolamo, A.; di Micco, B.; di Nardo, R.; di Petrillo, K. F.; di Simone, A.; di Sipio, R.; di Valentino, D.; Diaconu, C.; Diamond, M.; Dias, F. A.; Diaz, M. A.; Dickinson, J.; Diehl, E. B.; Dietrich, J.; Díez Cornell, S.; Dimitrievska, A.; Dingfelder, J.; Dita, P.; Dita, S.; Dittus, F.; Djama, F.; Djobava, T.; Djuvsland, J. I.; Do Vale, M. A. B.; Dobre, M.; Dodsworth, D.; Doglioni, C.; Dolejsi, J.; Dolezal, Z.; Donadelli, M.; Donati, S.; Donini, J.; Dopke, J.; Doria, A.; Dova, M. T.; Doyle, A. T.; Drechsler, E.; Dreyer, E.; Dris, M.; Du, Y.; Duarte-Campderros, J.; Dubinin, F.; Dubreuil, A.; Duchovni, E.; Duckeck, G.; Ducourthial, A.; Ducu, O. A.; Duda, D.; Dudarev, A.; Dudder, A. Chr.; Duffield, E. M.; Duflot, L.; Dührssen, M.; Dulsen, C.; Dumancic, M.; Dumitriu, A. E.; Duncan, A. K.; Dunford, M.; Duperrin, A.; Duran Yildiz, H.; Düren, M.; Durglishvili, A.; Duschinger, D.; Dutta, B.; Duvnjak, D.; Dyndal, M.; Dziedzic, B. S.; Eckardt, C.; Ecker, K. M.; Edgar, R. C.; Eifert, T.; Eigen, G.; Einsweiler, K.; Ekelof, T.; El Kacimi, M.; El Kosseifi, R.; Ellajosyula, V.; Ellert, M.; Ellinghaus, F.; Elliot, A. A.; Ellis, N.; Elmsheuser, J.; Elsing, M.; Emeliyanov, D.; Enari, Y.; Ennis, J. S.; Epland, M. B.; Erdmann, J.; Ereditato, A.; Errede, S.; Escalier, M.; Escobar, C.; Esposito, B.; Estrada Pastor, O.; Etienvre, A. I.; Etzion, E.; Evans, H.; Ezhilov, A.; Ezzi, M.; Fabbri, F.; Fabbri, L.; Fabiani, V.; Facini, G.; Fakhrutdinov, R. M.; Falciano, S.; Faltova, J.; Fang, Y.; Fanti, M.; Farbin, A.; Farilla, A.; Farina, E. M.; Farooque, T.; Farrell, S.; Farrington, S. M.; Farthouat, P.; Fassi, F.; Fassnacht, P.; Fassouliotis, D.; Faucci Giannelli, M.; Favareto, A.; Fawcett, W. J.; Fayard, L.; Fedin, O. L.; Fedorko, W.; Feickert, M.; Feigl, S.; Feligioni, L.; Feng, C.; Feng, E. J.; Feng, M.; Fenton, M. J.; Fenyuk, A. B.; Feremenga, L.; Fernandez Martinez, P.; Ferrando, J.; Ferrari, A.; Ferrari, P.; Ferrari, R.; Ferreira de Lima, D. E.; Ferrer, A.; Ferrere, D.; Ferretti, C.; Fiedler, F.; Filipčič, A.; Filthaut, F.; Fincke-Keeler, M.; Finelli, K. D.; Fiolhais, M. C. N.; Fiorini, L.; Fischer, C.; Fischer, J.; Fisher, W. C.; Flaschel, N.; Fleck, I.; Fleischmann, P.; Fletcher, R. R. M.; Flick, T.; Flierl, B. M.; Flores, L. M.; Flores Castillo, L. R.; Fomin, N.; Forcolin, G. T.; Formica, A.; Förster, F. A.; Forti, A.; Foster, A. G.; Fournier, D.; Fox, H.; Fracchia, S.; Francavilla, P.; Franchini, M.; Franchino, S.; Francis, D.; Franconi, L.; Franklin, M.; Frate, M.; Fraternali, M.; Freeborn, D.; Fressard-Batraneanu, S. M.; Freund, B.; Freund, W. S.; Froidevaux, D.; Frost, J. A.; Fukunaga, C.; Fusayasu, T.; Fuster, J.; Gabizon, O.; Gabrielli, A.; Gabrielli, A.; Gach, G. P.; Gadatsch, S.; Gadomski, S.; Gagliardi, G.; Gagnon, L. G.; Galea, C.; Galhardo, B.; Gallas, E. J.; Gallop, B. J.; Gallus, P.; Galster, G.; Gan, K. K.; Ganguly, S.; Gao, Y.; Gao, Y. S.; Garay Walls, F. M.; García, C.; García Navarro, J. E.; García Pascual, J. A.; Garcia-Sciveres, M.; Gardner, R. W.; Garelli, N.; Garonne, V.; Gasnikova, K.; Gaudiello, A.; Gaudio, G.; Gavrilenko, I. L.; Gay, C.; Gaycken, G.; Gazis, E. N.; Gee, C. N. P.; Geisen, J.; Geisen, M.; Geisler, M. P.; Gellerstedt, K.; Gemme, C.; Genest, M. H.; Geng, C.; Gentile, S.; Gentsos, C.; George, S.; Gerbaudo, D.; Geßner, G.; Ghasemi, S.; Ghneimat, M.; Giacobbe, B.; Giagu, S.; Giangiacomi, N.; Giannetti, P.; Gibson, S. M.; Gignac, M.; Gilchriese, M.; Gillberg, D.; Gilles, G.; Gingrich, D. M.; Giordani, M. P.; Giorgi, F. M.; Giraud, P. F.; Giromini, P.; Giugliarelli, G.; Giugni, D.; Giuli, F.; Giulini, M.; Gkaitatzis, S.; Gkialas, I.; Gkougkousis, E. L.; Gkountoumis, P.; Gladilin, L. K.; Glasman, C.; Glatzer, J.; Glaysher, P. C. F.; Glazov, A.; Goblirsch-Kolb, M.; Godlewski, J.; Goldfarb, S.; Golling, T.; Golubkov, D.; Gomes, A.; Gonçalo, R.; Goncalves Gama, R.; Gonella, G.; Gonella, L.; Gongadze, A.; Gonnella, F.; Gonski, J. L.; González de La Hoz, S.; Gonzalez-Sevilla, S.; Goossens, L.; Gorbounov, P. A.; Gordon, H. A.; Gorini, B.; Gorini, E.; Gorišek, A.; Goshaw, A. T.; Gössling, C.; Gostkin, M. I.; Gottardo, C. A.; Goudet, C. R.; Goujdami, D.; Goussiou, A. G.; Govender, N.; Goy, C.; Gozani, E.; Grabowska-Bold, I.; Gradin, P. O. J.; Graham, E. C.; Gramling, J.; Gramstad, E.; Grancagnolo, S.; Gratchev, V.; Gravila, P. M.; Gray, C.; Gray, H. M.; Greenwood, Z. D.; Grefe, C.; Gregersen, K.; Gregor, I. M.; Grenier, P.; Grevtsov, K.; Griffiths, J.; Grillo, A. A.; Grimm, K.; Grinstein, S.; Gris, Ph.; Grivaz, J.-F.; Groh, S.; Gross, E.; Grosse-Knetter, J.; Grossi, G. C.; Grout, Z. J.; Grummer, A.; Guan, L.; Guan, W.; Guenther, J.; Guerguichon, A.; Guescini, F.; Guest, D.; Gueta, O.; Gugel, R.; Gui, B.; Guillemin, T.; Guindon, S.; Gul, U.; Gumpert, C.; Guo, J.; Guo, W.; Guo, Y.; Gupta, R.; Gurbuz, S.; Gustavino, G.; Gutelman, B. J.; Gutierrez, P.; Gutierrez Ortiz, N. G.; Gutschow, C.; Guyot, C.; Guzik, M. P.; Gwenlan, C.; Gwilliam, C. B.; Haas, A.; Haber, C.; Hadavand, H. K.; Haddad, N.; Hadef, A.; Hageböck, S.; Hagihara, M.; Hakobyan, H.; Haleem, M.; Haley, J.; Halladjian, G.; Hallewell, G. D.; Hamacher, K.; Hamal, P.; Hamano, K.; Hamilton, A.; Hamity, G. N.; Han, K.; Han, L.; Han, S.; Hanagaki, K.; Hance, M.; Handl, D. M.; Haney, B.; Hankache, R.; Hanke, P.; Hansen, E.; Hansen, J. B.; Hansen, J. D.; Hansen, M. C.; Hansen, P. H.; Hara, K.; Hard, A. S.; Harenberg, T.; Harkusha, S.; Harrison, P. F.; Hartmann, N. M.; Hasegawa, Y.; Hasib, A.; Hassani, S.; Haug, S.; Hauser, R.; Hauswald, L.; Havener, L. B.; Havranek, M.; Hawkes, C. M.; Hawkings, R. J.; Hayden, D.; Hays, C. P.; Hays, J. M.; Hayward, H. S.; Haywood, S. J.; Heck, T.; Hedberg, V.; Heelan, L.; Heer, S.; Heidegger, K. K.; Heim, S.; Heim, T.; Heinemann, B.; Heinrich, J. J.; Heinrich, L.; Heinz, C.; Hejbal, J.; Helary, L.; Held, A.; Hellman, S.; Helsens, C.; Henderson, R. C. W.; Heng, Y.; Henkelmann, S.; Henriques Correia, A. M.; Herbert, G. H.; Herde, H.; Herget, V.; Hernández Jiménez, Y.; Herr, H.; Herten, G.; Hertenberger, R.; Hervas, L.; Herwig, T. C.; Hesketh, G. G.; Hessey, N. P.; Hetherly, J. W.; Higashino, S.; Higón-Rodriguez, E.; Hildebrand, K.; Hill, E.; Hill, J. C.; Hiller, K. H.; Hillier, S. J.; Hils, M.; Hinchliffe, I.; Hirose, M.; Hirschbuehl, D.; Hiti, B.; Hladik, O.; Hlaluku, D. R.; Hoad, X.; Hobbs, J.; Hod, N.; Hodgkinson, M. C.; Hoecker, A.; Hoeferkamp, M. R.; Hoenig, F.; Hohn, D.; Hohov, D.; Holmes, T. R.; Holzbock, M.; Homann, M.; Honda, S.; Honda, T.; Hong, T. M.; Hooberman, B. H.; Hopkins, W. H.; Horii, Y.; Horton, A. J.; Horyn, L. A.; Hostachy, J.-Y.; Hostiuc, A.; Hou, S.; Hoummada, A.; Howarth, J.; Hoya, J.; Hrabovsky, M.; Hrdinka, J.; Hristova, I.; Hrivnac, J.; Hryn'ova, T.; Hrynevich, A.; Hsu, P. J.; Hsu, S.-C.; Hu, Q.; Hu, S.; Huang, Y.; Hubacek, Z.; Hubaut, F.; Huegging, F.; Huffman, T. B.; Hughes, E. W.; Huhtinen, M.; Hunter, R. F. H.; Huo, P.; Hupe, A. M.; Huseynov, N.; Huston, J.; Huth, J.; Hyneman, R.; Iacobucci, G.; Iakovidis, G.; Ibragimov, I.; Iconomidou-Fayard, L.; Idrissi, Z.; Iengo, P.; Igonkina, O.; Iguchi, R.; Iizawa, T.; Ikegami, Y.; Ikeno, M.; Iliadis, D.; Ilic, N.; Iltzsche, F.; Introzzi, G.; Iodice, M.; Iordanidou, K.; Ippolito, V.; Isacson, M. F.; Ishijima, N.; Ishino, M.; Ishitsuka, M.; Issever, C.; Istin, S.; Ito, F.; Iturbe Ponce, J. M.; Iuppa, R.; Iwasaki, H.; Izen, J. M.; Izzo, V.; Jabbar, S.; Jackson, P.; Jacobs, R. M.; Jain, V.; Jakel, G.; Jakobi, K. B.; Jakobs, K.; Jakobsen, S.; Jakoubek, T.; Jamin, D. O.; Jana, D. K.; Jansky, R.; Janssen, J.; Janus, M.; Janus, P. A.; Jarlskog, G.; Javadov, N.; Javå¯Rek, T.; Javurkova, M.; Jeanneau, F.; Jeanty, L.; Jejelava, J.; Jelinskas, A.; Jenni, P.; Jeske, C.; Jézéquel, S.; Ji, H.; Jia, J.; Jiang, H.; Jiang, Y.; Jiang, Z.; Jiggins, S.; Jimenez Pena, J.; Jin, S.; Jinaru, A.; Jinnouchi, O.; Jivan, H.; Johansson, P.; Johns, K. A.; Johnson, C. A.; Johnson, W. J.; Jon-And, K.; Jones, R. W. L.; Jones, S. D.; Jones, S.; Jones, T. J.; Jongmanns, J.; Jorge, P. M.; Jovicevic, J.; Ju, X.; Junggeburth, J. J.; Juste Rozas, A.; Kaczmarska, A.; Kado, M.; Kagan, H.; Kagan, M.; Kahn, S. J.; Kaji, T.; Kajomovitz, E.; Kalderon, C. W.; Kaluza, A.; Kama, S.; Kamenshchikov, A.; Kanjir, L.; Kano, Y.; Kantserov, V. A.; Kanzaki, J.; Kaplan, B.; Kaplan, L. S.; Kar, D.; Karakostas, K.; Karastathis, N.; Kareem, M. J.; Karentzos, E.; Karpov, S. N.; Karpova, Z. M.; Kartvelishvili, V.; Karyukhin, A. N.; Kasahara, K.; Kashif, L.; Kass, R. D.; Kastanas, A.; Kataoka, Y.; Kato, C.; Katre, A.; Katzy, J.; Kawade, K.; Kawagoe, K.; Kawamoto, T.; Kawamura, G.; Kay, E. F.; Kazanin, V. F.; Keeler, R.; Kehoe, R.; Keller, J. S.; Kellermann, E.; Kempster, J. J.; Kendrick, J.; Keoshkerian, H.; Kepka, O.; Kerševan, B. P.; Kersten, S.; Keyes, R. A.; Khader, M.; Khalil-Zada, F.; Khanov, A.; Kharlamov, A. G.; Kharlamova, T.; Khodinov, A.; Khoo, T. J.; Khovanskiy, V.; Khramov, E.; Khubua, J.; Kido, S.; Kiehn, M.; Kilby, C. R.; Kim, H. Y.; Kim, S. H.; Kim, Y. K.; Kimura, N.; Kind, O. M.; King, B. T.; Kirchmeier, D.; Kirk, J.; Kiryunin, A. E.; Kishimoto, T.; Kisielewska, D.; Kitali, V.; Kivernyk, O.; Kladiva, E.; Klapdor-Kleingrothaus, T.; Klein, M. H.; Klein, M.; Klein, U.; Kleinknecht, K.; Klimek, P.; Klimentov, A.; Klingenberg, R.; Klingl, T.; Klioutchnikova, T.; Klitzner, F. F.; Kluge, E.-E.; Kluit, P.; Kluth, S.; Kneringer, E.; Knoops, E. B. F. G.; Knue, A.; Kobayashi, A.; Kobayashi, D.; Kobayashi, T.; Kobel, M.; Kocian, M.; Kodys, P.; Koffas, T.; Koffeman, E.; Köhler, N. M.; Koi, T.; Kolb, M.; Koletsou, I.; Kondo, T.; Kondrashova, N.; Köneke, K.; König, A. C.; Kono, T.; Konoplich, R.; Konstantinidis, N.; Konya, B.; Kopeliansky, R.; Koperny, S.; Korcyl, K.; Kordas, K.; Korn, A.; Korolkov, I.; Korolkova, E. V.; Kortner, O.; Kortner, S.; Kosek, T.; Kostyukhin, V. V.; Kotwal, A.; Koulouris, A.; Kourkoumeli-Charalampidi, A.; Kourkoumelis, C.; Kourlitis, E.; Kouskoura, V.; Kowalewska, A. B.; Kowalewski, R.; Kowalski, T. Z.; Kozakai, C.; Kozanecki, W.; Kozhin, A. S.; Kramarenko, V. A.; Kramberger, G.; Krasnopevtsev, D.; Krasny, M. W.; Krasznahorkay, A.; Krauss, D.; Kremer, J. A.; Kretzschmar, J.; Kreutzfeldt, K.; Krieger, P.; Krizka, K.; Kroeninger, K.; Kroha, H.; Kroll, J.; Kroll, J.; Kroseberg, J.; Krstic, J.; Kruchonak, U.; Krüger, H.; Krumnack, N.; Kruse, M. C.; Kubota, T.; Kuday, S.; Kuechler, J. T.; Kuehn, S.; Kugel, A.; Kuger, F.; Kuhl, T.; Kukhtin, V.; Kukla, R.; Kulchitsky, Y.; Kuleshov, S.; Kulinich, Y. P.; Kuna, M.; Kunigo, T.; Kupco, A.; Kupfer, T.; Kuprash, O.; Kurashige, H.; Kurchaninov, L. L.; Kurochkin, Y. A.; Kurth, M. G.; Kuwertz, E. S.; Kuze, M.; Kvita, J.; Kwan, T.; La Rosa, A.; La Rosa Navarro, J. L.; La Rotonda, L.; La Ruffa, F.; Lacasta, C.; Lacava, F.; Lacey, J.; Lack, D. P. J.; Lacker, H.; Lacour, D.; Ladygin, E.; Lafaye, R.; Laforge, B.; Lai, S.; Lammers, S.; Lampl, W.; Lançon, E.; Landgraf, U.; Landon, M. P. J.; Lanfermann, M. C.; Lang, V. S.; Lange, J. C.; Langenberg, R. J.; Lankford, A. J.; Lanni, F.; Lantzsch, K.; Lanza, A.; Lapertosa, A.; Laplace, S.; Laporte, J. F.; Lari, T.; Lasagni Manghi, F.; Lassnig, M.; Lau, T. S.; Laudrain, A.; Law, A. T.; Laycock, P.; Lazzaroni, M.; Le, B.; Le Dortz, O.; Le Guirriec, E.; Le Quilleuc, E. P.; Leblanc, M.; Lecompte, T.; Ledroit-Guillon, F.; Lee, C. A.; Lee, G. R.; Lee, S. C.; Lee, L.; Lefebvre, B.; Lefebvre, M.; Legger, F.; Leggett, C.; Lehmann Miotto, G.; Leight, W. A.; Leisos, A.; Leite, M. A. L.; Leitner, R.; Lellouch, D.; Lemmer, B.; Leney, K. J. C.; Lenz, T.; Lenzi, B.; Leone, R.; Leone, S.; Leonidopoulos, C.; Lerner, G.; Leroy, C.; Les, R.; Lesage, A. A. J.; Lester, C. G.; Levchenko, M.; Levêque, J.; Levin, D.; Levinson, L. J.; Levy, M.; Lewis, D.; Li, B.; Li, C.-Q.; Li, H.; Li, L.; Li, Q.; Li, Q.; Li, S.; Li, X.; Li, Y.; Liang, Z.; Liberti, B.; Liblong, A.; Lie, K.; Limosani, A.; Lin, C. Y.; Lin, K.; Lin, S. C.; Lin, T. H.; Linck, R. A.; Lindquist, B. E.; Lionti, A. E.; Lipeles, E.; Lipniacka, A.; Lisovyi, M.; Liss, T. M.; Lister, A.; Litke, A. M.; Liu, B.; Liu, H.; Liu, H.; Liu, J. K. K.; Liu, J. B.; Liu, K.; Liu, M.; Liu, P.; Liu, Y. L.; Liu, Y.; Livan, M.; Lleres, A.; Llorente Merino, J.; Lloyd, S. L.; Lo, C. Y.; Lo Sterzo, F.; Lobodzinska, E. M.; Loch, P.; Loebinger, F. K.; Loesle, A.; Loew, K. M.; Lohse, T.; Lohwasser, K.; Lokajicek, M.; Long, B. A.; Long, J. D.; Long, R. E.; Longo, L.; Looper, K. A.; Lopez, J. A.; Lopez Paz, I.; Lopez Solis, A.; Lorenz, J.; Lorenzo Martinez, N.; Losada, M.; Lösel, P. J.; Lou, X.; Lounis, A.; Love, J.; Love, P. A.; Lu, H.; Lu, N.; Lu, Y. J.; Lubatti, H. J.; Luci, C.; Lucotte, A.; Luedtke, C.; Luehring, F.; Lukas, W.; Luminari, L.; Lund-Jensen, B.; Lutz, M. S.; Luzi, P. M.; Lynn, D.; Lysak, R.; Lytken, E.; Lyu, F.; Lyubushkin, V.; Ma, H.; Ma, L. L.; Ma, Y.; Maccarrone, G.; Macchiolo, A.; MacDonald, C. M.; Maček, B.; Machado Miguens, J.; Madaffari, D.; Madar, R.; Mader, W. F.; Madsen, A.; Madysa, N.; Maeda, J.; Maeland, S.; Maeno, T.; Maevskiy, A. S.; Magerl, V.; Maidantchik, C.; Maier, T.; Maio, A.; Majersky, O.; Majewski, S.; Makida, Y.; Makovec, N.; Malaescu, B.; Malecki, Pa.; Maleev, V. P.; Malek, F.; Mallik, U.; Malon, D.; Malone, C.; Maltezos, S.; Malyukov, S.; Mamuzic, J.; Mancini, G.; Mandić, I.; Maneira, J.; Manhaes de Andrade Filho, L.; Manjarres Ramos, J.; Mankinen, K. H.; Mann, A.; Manousos, A.; Mansoulie, B.; Mansour, J. D.; Mantifel, R.; Mantoani, M.; Manzoni, S.; Marceca, G.; March, L.; Marchese, L.; Marchiori, G.; Marcisovsky, M.; Marin Tobon, C. A.; Marjanovic, M.; Marley, D. E.; Marroquim, F.; Marshall, Z.; Martensson, M. U. F.; Marti-Garcia, S.; Martin, C. B.; Martin, T. A.; Martin, V. J.; Martin Dit Latour, B.; Martinez, M.; Martinez Outschoorn, V. I.; Martin-Haugh, S.; Martoiu, V. S.; Martyniuk, A. C.; Marzin, A.; Masetti, L.; Mashimo, T.; Mashinistov, R.; Masik, J.; Maslennikov, A. L.; Mason, L. H.; Massa, L.; Mastrandrea, P.; Mastroberardino, A.; Masubuchi, T.; Mättig, P.; Maurer, J.; Maxfield, S. J.; Maximov, D. A.; Mazini, R.; Maznas, I.; Mazza, S. M.; Mc Fadden, N. C.; Mc Goldrick, G.; Mc Kee, S. P.; McCarn, A.; McCarthy, T. G.; McClymont, L. I.; McDonald, E. F.; McFayden, J. A.; McHedlidze, G.; McKay, M. A.; McMahon, S. J.; McNamara, P. C.; McNicol, C. J.; McPherson, R. A.; Meadows, Z. A.; Meehan, S.; Megy, T. J.; Mehlhase, S.; Mehta, A.; Meideck, T.; Meier, K.; Meirose, B.; Melini, D.; Mellado Garcia, B. R.; Mellenthin, J. D.; Melo, M.; Meloni, F.; Melzer, A.; Menary, S. B.; Meng, L.; Meng, X. T.; Mengarelli, A.; Menke, S.; Meoni, E.; Mergelmeyer, S.; Merlassino, C.; Mermod, P.; Merola, L.; Meroni, C.; Merritt, F. S.; Messina, A.; Metcalfe, J.; Mete, A. S.; Meyer, C.; Meyer, J.-P.; Meyer, J.; Meyer Zu Theenhausen, H.; Miano, F.; Middleton, R. P.; Miglioranzi, S.; Mijović, L.; Mikenberg, G.; Mikestikova, M.; Mikuž, M.; Milesi, M.; Milic, A.; Millar, D. A.; Miller, D. W.; Milov, A.; Milstead, D. A.; Minaenko, A. A.; Minashvili, I. A.; Mincer, A. I.; Mindur, B.; Mineev, M.; Minegishi, Y.; Ming, Y.; Mir, L. M.; Mirto, A.; Mistry, K. P.; Mitani, T.; Mitrevski, J.; Mitsou, V. A.; Miucci, A.; Miyagawa, P. S.; Mizukami, A.; Mjörnmark, J. U.; Mkrtchyan, T.; Mlynarikova, M.; Moa, T.; Mochizuki, K.; Mogg, P.; Mohapatra, S.; Molander, S.; Moles-Valls, R.; Mondragon, M. C.; Mönig, K.; Monk, J.; Monnier, E.; Montalbano, A.; Montejo Berlingen, J.; Monticelli, F.; Monzani, S.; Moore, R. W.; Morange, N.; Moreno, D.; Moreno Llácer, M.; Morettini, P.; Morgenstern, M.; Morgenstern, S.; Mori, D.; Mori, T.; Morii, M.; Morinaga, M.; Morisbak, V.; Morley, A. K.; Mornacchi, G.; Morris, J. D.; Morvaj, L.; Moschovakos, P.; Mosidze, M.; Moss, H. J.; Moss, J.; Motohashi, K.; Mount, R.; Mountricha, E.; Moyse, E. J. W.; Muanza, S.; Mueller, F.; Mueller, J.; Mueller, R. S. P.; Muenstermann, D.; Mullen, P.; Mullier, G. A.; Munoz Sanchez, F. J.; Murin, P.; Murray, W. J.; Murrone, A.; Muškinja, M.; Mwewa, C.; Myagkov, A. G.; Myers, J.; Myska, M.; Nachman, B. P.; Nackenhorst, O.; Nagai, K.; Nagai, R.; Nagano, K.; Nagasaka, Y.; Nagata, K.; Nagel, M.; Nagy, E.; Nairz, A. M.; Nakahama, Y.; Nakamura, K.; Nakamura, T.; Nakano, I.; Naranjo Garcia, R. F.; Narayan, R.; Narrias Villar, D. I.; Naryshkin, I.; Naumann, T.; Navarro, G.; Nayyar, R.; Neal, H. A.; Nechaeva, P. Yu.; Neep, T. J.; Negri, A.; Negrini, M.; Nektarijevic, S.; Nellist, C.; Nelson, M. E.; Nemecek, S.; Nemethy, P.; Nessi, M.; Neubauer, M. S.; Neumann, M.; Newman, P. R.; Ng, T. Y.; Ng, Y. S.; Nguyen Manh, T.; Nickerson, R. B.; Nicolaidou, R.; Nielsen, J.; Nikiforou, N.; Nikolaenko, V.; Nikolic-Audit, I.; Nikolopoulos, K.; Nilsson, P.; Ninomiya, Y.; Nisati, A.; Nishu, N.; Nisius, R.; Nitsche, I.; Nitta, T.; Nobe, T.; Noguchi, Y.; Nomachi, M.; Nomidis, I.; Nomura, M. A.; Nooney, T.; Nordberg, M.; Norjoharuddeen, N.; Novgorodova, O.; Novotny, R.; Nozaki, M.; Nozka, L.; Ntekas, K.; Nurse, E.; Nuti, F.; O'Connor, K.; O'Neil, D. C.; O'Rourke, A. A.; O'Shea, V.; Oakham, F. G.; Oberlack, H.; Obermann, T.; Ocariz, J.; Ochi, A.; Ochoa, I.; Ochoa-Ricoux, J. P.; Oda, S.; Odaka, S.; Oh, A.; Oh, S. H.; Ohm, C. C.; Ohman, H.; Oide, H.; Ojeda, M. L.; Okawa, H.; Okumura, Y.; Okuyama, T.; Olariu, A.; Oleiro Seabra, L. F.; Olivares Pino, S. A.; Oliveira Damazio, D.; Oliver, J. L.; Olsson, M. J. R.; Olszewski, A.; Olszowska, J.; Onofre, A.; Onogi, K.; Onyisi, P. U. E.; Oppen, H.; Oreglia, M. J.; Oren, Y.; Orestano, D.; Orgill, E. C.; Orlando, N.; Orr, R. S.; Osculati, B.; Ospanov, R.; Otero Y Garzon, G.; Otono, H.; Ouchrif, M.; Ould-Saada, F.; Ouraou, A.; Oussoren, K. P.; Ouyang, Q.; Owen, M.; Owen, R. E.; Ozcan, V. E.; Ozturk, N.; Pachal, K.; Pacheco Pages, A.; Pacheco Rodriguez, L.; Padilla Aranda, C.; Pagan Griso, S.; Paganini, M.; Paige, F.; Palacino, G.; Palazzo, S.; Palestini, S.; Palka, M.; Pallin, D.; Panagiotopoulou, E. St.; Panagoulias, I.; Pandini, C. E.; Panduro Vazquez, J. G.; Pani, P.; Pantea, D.; Paolozzi, L.; Papadopoulou, Th. D.; Papageorgiou, K.; Paramonov, A.; Paredes Hernandez, D.; Parida, B.; Parker, A. J.; Parker, M. A.; Parker, K. A.; Parodi, F.; Parsons, J. A.; Parzefall, U.; Pascuzzi, V. R.; Pasner, J. M.; Pasqualucci, E.; Passaggio, S.; Pastore, Fr.; Pataraia, S.; Pater, J. R.; Pauly, T.; Pearson, B.; Pedraza Lopez, S.; Pedro, R.; Peleganchuk, S. V.; Penc, O.; Peng, C.; Peng, H.; Penwell, J.; Peralva, B. S.; Perego, M. M.; Perepelitsa, D. V.; Peri, F.; Perini, L.; Pernegger, H.; Perrella, S.; Peshekhonov, V. D.; Peters, K.; Peters, R. F. Y.; Petersen, B. A.; Petersen, T. C.; Petit, E.; Petridis, A.; Petridou, C.; Petroff, P.; Petrolo, E.; Petrov, M.; Petrucci, F.; Pettersson, N. E.; Peyaud, A.; Pezoa, R.; Pham, T.; Phillips, F. H.; Phillips, P. W.; Piacquadio, G.; Pianori, E.; Picazio, A.; Pickering, M. A.; Piegaia, R.; Pilcher, J. E.; Pilkington, A. D.; Pinamonti, M.; Pinfold, J. L.; Pitt, M.; Pleier, M.-A.; Pleskot, V.; Plotnikova, E.; Pluth, D.; Podberezko, P.; Poettgen, R.; Poggi, R.; Poggioli, L.; Pogrebnyak, I.; Pohl, D.; Pokharel, I.; Polesello, G.; Poley, A.; Policicchio, A.; Polifka, R.; Polini, A.; Pollard, C. S.; Polychronakos, V.; Ponomarenko, D.; Pontecorvo, L.; Popeneciu, G. A.; Portillo Quintero, D. M.; Pospisil, S.; Potamianos, K.; Potrap, I. N.; Potter, C. J.; Potti, H.; Poulsen, T.; Poveda, J.; Pozo Astigarraga, M. E.; Pralavorio, P.; Prell, S.; Price, D.; Primavera, M.; Prince, S.; Proklova, N.; Prokofiev, K.; Prokoshin, F.; Protopopescu, S.; Proudfoot, J.; Przybycien, M.; Puri, A.; Puzo, P.; Qian, J.; Qin, Y.; Quadt, A.; Queitsch-Maitland, M.; Qureshi, A.; Radeka, V.; Radhakrishnan, S. K.; Rados, P.; Ragusa, F.; Rahal, G.; Raine, J. A.; Rajagopalan, S.; Rashid, T.; Raspopov, S.; Ratti, M. G.; Rauch, D. M.; Rauscher, F.; Rave, S.; Ravinovich, I.; Rawling, J. H.; Raymond, M.; Read, A. L.; Readioff, N. P.; Reale, M.; Rebuzzi, D. M.; Redelbach, A.; Redlinger, G.; Reece, R.; Reed, R. G.; Reeves, K.; Rehnisch, L.; Reichert, J.; Reiss, A.; Rembser, C.; Ren, H.; Rescigno, M.; Resconi, S.; Resseguie, E. D.; Rettie, S.; Reynolds, E.; Rezanova, O. L.; Reznicek, P.; Richter, R.; Richter, S.; Richter-Was, E.; Ricken, O.; Ridel, M.; Rieck, P.; Riegel, C. J.; Rifki, O.; Rijssenbeek, M.; Rimoldi, A.; Rimoldi, M.; Rinaldi, L.; Ripellino, G.; Ristić, B.; Ritsch, E.; Riu, I.; Rivera Vergara, J. C.; Rizatdinova, F.; Rizvi, E.; Rizzi, C.; Roberts, R. T.; Robertson, S. H.; Robichaud-Veronneau, A.; Robinson, D.; Robinson, J. E. M.; Robson, A.; Rocco, E.; Roda, C.; Rodina, Y.; Rodriguez Bosca, S.; Rodriguez Perez, A.; Rodriguez Rodriguez, D.; Rodríguez Vera, A. M.; Roe, S.; Rogan, C. S.; Røhne, O.; Röhrig, R.; Roloff, J.; Romaniouk, A.; Romano, M.; Romano Saez, S. M.; Romero Adam, E.; Rompotis, N.; Ronzani, M.; Roos, L.; Rosati, S.; Rosbach, K.; Rose, P.; Rosien, N.-A.; Rossi, E.; Rossi, L. P.; Rossini, L.; Rosten, J. H. N.; Rosten, R.; Rotaru, M.; Rothberg, J.; Rousseau, D.; Roy, D.; Rozanov, A.; Rozen, Y.; Ruan, X.; Rubbo, F.; Rühr, F.; Ruiz-Martinez, A.; Rurikova, Z.; Rusakovich, N. A.; Russell, H. L.; Rutherfoord, J. P.; Ruthmann, N.; Rüttinger, E. M.; Ryabov, Y. F.; Rybar, M.; Rybkin, G.; Ryu, S.; Ryzhov, A.; Rzehorz, G. F.; Saavedra, A. F.; Sabato, G.; Sacerdoti, S.; Sadrozinski, H. F.-W.; Sadykov, R.; Safai Tehrani, F.; Saha, P.; Sahinsoy, M.; Saimpert, M.; Saito, M.; Saito, T.; Sakamoto, H.; Salamanna, G.; Salazar Loyola, J. E.; Salek, D.; Sales de Bruin, P. H.; Salihagic, D.; Salnikov, A.; Salt, J.; Salvatore, D.; Salvatore, F.; Salvucci, A.; Salzburger, A.; Sammel, D.; Sampsonidis, D.; Sampsonidou, D.; Sánchez, J.; Sanchez Pineda, A.; Sandaker, H.; Sander, C. O.; Sandhoff, M.; Sandoval, C.; Sankey, D. P. C.; Sannino, M.; Sano, Y.; Sansoni, A.; Santoni, C.; Santos, H.; Santoyo Castillo, I.; Sapronov, A.; Saraiva, J. G.; Sasaki, O.; Sato, K.; Sauvan, E.; Savard, P.; Savic, N.; Sawada, R.; Sawyer, C.; Sawyer, L.; Sbarra, C.; Sbrizzi, A.; Scanlon, T.; Scannicchio, D. A.; Schaarschmidt, J.; Schacht, P.; Schachtner, B. M.; Schaefer, D.; Schaefer, L.; Schaeffer, J.; Schaepe, S.; Schäfer, U.; Schaffer, A. C.; Schaile, D.; Schamberger, R. D.; Schegelsky, V. A.; Scheirich, D.; Schenck, F.; Schernau, M.; Schiavi, C.; Schier, S.; Schildgen, L. K.; Schillaci, Z. M.; Schillo, C.; Schioppa, E. J.; Schioppa, M.; Schleicher, K. E.; Schlenker, S.; Schmidt-Sommerfeld, K. R.; Schmieden, K.; Schmitt, C.; Schmitt, S.; Schmitz, S.; Schnoor, U.; Schoeffel, L.; Schoening, A.; Schopf, E.; Schott, M.; Schouwenberg, J. F. P.; Schovancova, J.; Schramm, S.; Schuh, N.; Schulte, A.; Schultz-Coulon, H.-C.; Schumacher, M.; Schumm, B. A.; Schune, Ph.; Schwartzman, A.; Schwarz, T. A.; Schweiger, H.; Schwemling, Ph.; Schwienhorst, R.; Schwindling, J.; Sciandra, A.; Sciolla, G.; Scornajenghi, M.; Scuri, F.; Scutti, F.; Scyboz, L. M.; Searcy, J.; Seema, P.; Seidel, S. C.; Seiden, A.; Seixas, J. M.; Sekhniaidze, G.; Sekhon, K.; Sekula, S. J.; Semprini-Cesari, N.; Senkin, S.; Serfon, C.; Serin, L.; Serkin, L.; Sessa, M.; Severini, H.; Šfiligoj, T.; Sforza, F.; Sfyrla, A.; Shabalina, E.; Shahinian, J. D.; Shaikh, N. W.; Shan, L. Y.; Shang, R.; Shank, J. T.; Shapiro, M.; Sharma, A. S.; Shatalov, P. B.; Shaw, K.; Shaw, S. M.; Shcherbakova, A.; Shehu, C. Y.; Shen, Y.; Sherafati, N.; Sherman, A. D.; Sherwood, P.; Shi, L.; Shimizu, S.; Shimmin, C. O.; Shimojima, M.; Shipsey, I. P. J.; Shirabe, S.; Shiyakova, M.; Shlomi, J.; Shmeleva, A.; Shoaleh Saadi, D.; Shochet, M. J.; Shojaii, S.; Shope, D. R.; Shrestha, S.; Shulga, E.; Sicho, P.; Sickles, A. M.; Sidebo, P. E.; Sideras Haddad, E.; Sidiropoulou, O.; Sidoti, A.; Siegert, F.; Sijacki, Dj.; Silva, J.; Silva, M.; Silverstein, S. B.; Simic, L.; Simion, S.; Simioni, E.; Simmons, B.; Simon, M.; Sinervo, P.; Sinev, N. B.; Sioli, M.; Siragusa, G.; Siral, I.; Sivoklokov, S. Yu.; Sjölin, J.; Skinner, M. B.; Skubic, P.; Slater, M.; Slavicek, T.; Slawinska, M.; Sliwa, K.; Slovak, R.; Smakhtin, V.; Smart, B. H.; Smiesko, J.; Smirnov, N.; Smirnov, S. Yu.; Smirnov, Y.; Smirnova, L. N.; Smirnova, O.; Smith, J. W.; Smith, M. N. K.; Smith, R. W.; Smizanska, M.; Smolek, K.; Snesarev, A. A.; Snyder, I. M.; Snyder, S.; Sobie, R.; Socher, F.; Soffa, A. M.; Soffer, A.; Søgaard, A.; Soh, D. A.; Sokhrannyi, G.; Solans Sanchez, C. A.; Solar, M.; Soldatov, E. Yu.; Soldevila, U.; Solodkov, A. A.; Soloshenko, A.; Solovyanov, O. V.; Solovyev, V.; Sommer, P.; Son, H.; Song, W.; Sopczak, A.; Sopkova, F.; Sosa, D.; Sotiropoulou, C. L.; Sottocornola, S.; Soualah, R.; Soukharev, A. M.; South, D.; Sowden, B. C.; Spagnolo, S.; Spalla, M.; Spangenberg, M.; Spanò, F.; Sperlich, D.; Spettel, F.; Spieker, T. M.; Spighi, R.; Spigo, G.; Spiller, L. A.; Spousta, M.; St. Denis, R. D.; Stabile, A.; Stamen, R.; Stamm, S.; Stanecka, E.; Stanek, R. W.; Stanescu, C.; Stanitzki, M. M.; Stapf, B. S.; Stapnes, S.; Starchenko, E. A.; Stark, G. H.; Stark, J.; Stark, S. H.; Staroba, P.; Starovoitov, P.; Stärz, S.; Staszewski, R.; Stegler, M.; Steinberg, P.; Stelzer, B.; Stelzer, H. J.; Stelzer-Chilton, O.; Stenzel, H.; Stevenson, T. J.; Stewart, G. A.; Stockton, M. C.; Stoicea, G.; Stolte, P.; Stonjek, S.; Straessner, A.; Stramaglia, M. E.; Strandberg, J.; Strandberg, S.; Strauss, M.; Strizenec, P.; Ströhmer, R.; Strom, D. M.; Stroynowski, R.; Strubig, A.; Stucci, S. A.; Stugu, B.; Styles, N. A.; Su, D.; Su, J.; Suchek, S.; Sugaya, Y.; Suk, M.; Sulin, V. V.; Sultan, D. M. S.; Sultansoy, S.; Sumida, T.; Sun, S.; Sun, X.; Suruliz, K.; Suster, C. J. E.; Sutton, M. R.; Suzuki, S.; Svatos, M.; Swiatlowski, M.; Swift, S. P.; Sydorenko, A.; Sykora, I.; Sykora, T.; Ta, D.; Tackmann, K.; Taenzer, J.; Taffard, A.; Tafirout, R.; Tahirovic, E.; Taiblum, N.; Takai, H.; Takashima, R.; Takasugi, E. H.; Takeda, K.; Takeshita, T.; Takubo, Y.; Talby, M.; Talyshev, A. A.; Tanaka, J.; Tanaka, M.; Tanaka, R.; Tanioka, R.; Tannenwald, B. B.; Tapia Araya, S.; Tapprogge, S.; Tarek Abouelfadl Mohamed, A. T.; Tarem, S.; Tarna, G.; Tartarelli, G. F.; Tas, P.; Tasevsky, M.; Tashiro, T.; Tassi, E.; Tavares Delgado, A.; Tayalati, Y.; Taylor, A. C.; Taylor, A. J.; Taylor, G. N.; Taylor, P. T. E.; Taylor, W.; Teixeira-Dias, P.; Temple, D.; Ten Kate, H.; Teng, P. K.; Teoh, J. J.; Tepel, F.; Terada, S.; Terashi, K.; Terron, J.; Terzo, S.; Testa, M.; Teuscher, R. J.; Thais, S. J.; Theveneaux-Pelzer, T.; Thiele, F.; Thomas, J. P.; Thompson, P. D.; Thompson, A. S.; Thomsen, L. A.; Thomson, E.; Tian, Y.; Ticse Torres, R. E.; Tikhomirov, V. O.; Tikhonov, Yu. A.; Timoshenko, S.; Tipton, P.; Tisserant, S.; Todome, K.; Todorova-Nova, S.; Todt, S.; Tojo, J.; Tokár, S.; Tokushuku, K.; Tolley, E.; Tomoto, M.; Tompkins, L.; Toms, K.; Tong, B.; Tornambe, P.; Torrence, E.; Torres, H.; Torró Pastor, E.; Toth, J.; Touchard, F.; Tovey, D. R.; Treado, C. J.; Trefzger, T.; Tresoldi, F.; Tricoli, A.; Trigger, I. M.; Trincaz-Duvoid, S.; Tripiana, M. F.; Trischuk, W.; Trocmé, B.; Trofymov, A.; Troncon, C.; Trovatelli, M.; Truong, L.; Trzebinski, M.; Trzupek, A.; Tsang, K. W.; Tseng, J. C.-L.; Tsiareshka, P. V.; Tsirintanis, N.; Tsiskaridze, S.; Tsiskaridze, V.; Tskhadadze, E. G.; Tsukerman, I. I.; Tsulaia, V.; Tsuno, S.; Tsybychev, D.; Tu, Y.; Tudorache, A.; Tudorache, V.; Tulbure, T. T.; Tuna, A. N.; Turchikhin, S.; Turgeman, D.; Turk Cakir, I.; Turra, R.; Tuts, P. M.; Ucchielli, G.; Ueda, I.; Ughetto, M.; Ukegawa, F.; Unal, G.; Undrus, A.; Unel, G.; Ungaro, F. C.; Unno, Y.; Uno, K.; Urban, J.; Urquijo, P.; Urrejola, P.; Usai, G.; Usui, J.; Vacavant, L.; Vacek, V.; Vachon, B.; Vadla, K. O. H.; Vaidya, A.; Valderanis, C.; Valdes Santurio, E.; Valente, M.; Valentinetti, S.; Valero, A.; Valéry, L.; Vallier, A.; Valls Ferrer, J. A.; van den Wollenberg, W.; van der Graaf, H.; van Gemmeren, P.; van Nieuwkoop, J.; van Vulpen, I.; van Woerden, M. C.; Vanadia, M.; Vandelli, W.; Vaniachine, A.; Vankov, P.; Vari, R.; Varnes, E. W.; Varni, C.; Varol, T.; Varouchas, D.; Vartapetian, A.; Varvell, K. E.; Vasquez, J. G.; Vasquez, G. A.; Vazeille, F.; Vazquez Furelos, D.; Vazquez Schroeder, T.; Veatch, J.; Vecchio, V.; Veloce, L. M.; Veloso, F.; Veneziano, S.; Ventura, A.; Venturi, M.; Venturi, N.; Vercesi, V.; Verducci, M.; Verkerke, W.; Vermeulen, A. T.; Vermeulen, J. C.; Vetterli, M. C.; Viaux Maira, N.; Viazlo, O.; Vichou, I.; Vickey, T.; Vickey Boeriu, O. E.; Viehhauser, G. H. A.; Viel, S.; Vigani, L.; Villa, M.; Villaplana Perez, M.; Vilucchi, E.; Vincter, M. G.; Vinogradov, V. B.; Vishwakarma, A.; Vittori, C.; Vivarelli, I.; Vlachos, S.; Vogel, M.; Vokac, P.; Volpi, G.; von Buddenbrock, S. E.; von Toerne, E.; Vorobel, V.; Vorobev, K.; Vos, M.; Vossebeld, J. H.; Vranjes, N.; Vranjes Milosavljevic, M.; Vrba, V.; Vreeswijk, M.; Vuillermet, R.; Vukotic, I.; Wagner, P.; Wagner, W.; Wagner-Kuhr, J.; Wahlberg, H.; Wahrmund, S.; Wakamiya, K.; Walder, J.; Walker, R.; Walkowiak, W.; Wallangen, V.; Wang, A. M.; Wang, C.; Wang, F.; Wang, H.; Wang, H.; Wang, J.; Wang, J.; Wang, Q.; Wang, R.-J.; Wang, R.; Wang, S. M.; Wang, T.; Wang, W.; Wang, W.; Wang, Z.; Wanotayaroj, C.; Warburton, A.; Ward, C. P.; Wardrope, D. R.; Washbrook, A.; Watkins, P. M.; Watson, A. T.; Watson, M. F.; Watts, G.; Watts, S.; Waugh, B. M.; Webb, A. F.; Webb, S.; Weber, M. S.; Weber, S. M.; Weber, S. A.; Webster, J. S.; Weidberg, A. R.; Weinert, B.; Weingarten, J.; Weirich, M.; Weiser, C.; Wells, P. S.; Wenaus, T.; Wengler, T.; Wenig, S.; Wermes, N.; Werner, M. D.; Werner, P.; Wessels, M.; Weston, T. D.; Whalen, K.; Whallon, N. L.; Wharton, A. M.; White, A. S.; White, A.; White, M. J.; White, R.; Whiteson, D.; Whitmore, B. W.; Wickens, F. J.; Wiedenmann, W.; Wielers, M.; Wiglesworth, C.; Wiik-Fuchs, L. A. M.; Wildauer, A.; Wilk, F.; Wilkens, H. G.; Williams, H. H.; Williams, S.; Willis, C.; Willocq, S.; Wilson, J. A.; Wingerter-Seez, I.; Winkels, E.; Winklmeier, F.; Winston, O. J.; Winter, B. T.; Wittgen, M.; Wobisch, M.; Wolf, A.; Wolf, T. M. H.; Wolff, R.; Wolter, M. W.; Wolters, H.; Wong, V. W. S.; Woods, N. L.; Worm, S. D.; Wosiek, B. K.; Wozniak, K. W.; Wu, M.; Wu, S. L.; Wu, X.; Wu, Y.; Wyatt, T. R.; Wynne, B. M.; Xella, S.; Xi, Z.; Xia, L.; Xu, D.; Xu, L.; Xu, T.; Xu, W.; Yabsley, B.; Yacoob, S.; Yajima, K.; Yallup, D. P.; Yamaguchi, D.; Yamaguchi, Y.; Yamamoto, A.; Yamanaka, T.; Yamane, F.; Yamatani, M.; Yamazaki, T.; Yamazaki, Y.; Yan, Z.; Yang, H.; Yang, H.; Yang, S.; Yang, Y.; Yang, Z.; Yao, W.-M.; Yap, Y. C.; Yasu, Y.; Yatsenko, E.; Yau Wong, K. H.; Ye, J.; Ye, S.; Yeletskikh, I.; Yigitbasi, E.; Yildirim, E.; Yorita, K.; Yoshihara, K.; Young, C.; Young, C. J. S.; Yu, J.; Yu, J.; Yuen, S. P. Y.; Yusuff, I.; Zabinski, B.; Zacharis, G.; Zaidan, R.; Zaitsev, A. M.; Zakharchuk, N.; Zalieckas, J.; Zambito, S.; Zanzi, D.; Zeitnitz, C.; Zemaityte, G.; Zeng, J. C.; Zeng, Q.; Zenin, O.; Ženiš, T.; Zerwas, D.; Zhang, D.; Zhang, D.; Zhang, F.; Zhang, G.; Zhang, H.; Zhang, J.; Zhang, L.; Zhang, L.; Zhang, M.; Zhang, P.; Zhang, R.; Zhang, R.; Zhang, X.; Zhang, Y.; Zhang, Z.; Zhao, X.; Zhao, Y.; Zhao, Z.; Zhemchugov, A.; Zhou, B.; Zhou, C.; Zhou, L.; Zhou, M.; Zhou, M.; Zhou, N.; Zhou, Y.; Zhu, C. G.; Zhu, H.; Zhu, J.; Zhu, Y.; Zhuang, X.; Zhukov, K.; Zhulanov, V.; Zibell, A.; Zieminska, D.; Zimine, N. I.; Zimmermann, S.; Zinonos, Z.; Zinser, M.; Ziolkowski, M.; Živković, L.; Zobernig, G.; Zoccoli, A.; Zou, R.; Zur Nedden, M.; Zwalinski, L.; Atlas Collaboration
2018-04-01
A search for the associated production of the Higgs boson with a top quark pair (t t ¯H ) is reported. The search is performed in multilepton final states using a data set corresponding to an integrated luminosity of 36.1 fb-1 of proton-proton collision data recorded by the ATLAS experiment at a center-of-mass energy √{s }=13 TeV at the Large Hadron Collider. Higgs boson decays to W W*, τ τ , and Z Z* are targeted. Seven final states, categorized by the number and flavor of charged-lepton candidates, are examined for the presence of the Standard Model Higgs boson with a mass of 125 GeV and a pair of top quarks. An excess of events over the expected background from Standard Model processes is found with an observed significance of 4.1 standard deviations, compared to an expectation of 2.8 standard deviations. The best fit for the t t ¯H production cross section is σ (t t ¯H )=79 0-210+230 fb , in agreement with the Standard Model prediction of 50 7-50+35 fb . The combination of this result with other t t ¯H searches from the ATLAS experiment using the Higgs boson decay modes to b b ¯, γ γ and Z Z*→4 ℓ, has an observed significance of 4.2 standard deviations, compared to an expectation of 3.8 standard deviations. This provides evidence for the t t ¯H production mode.
WASP (Write a Scientific Paper) using Excel -5: Quartiles and standard deviation.
Grech, Victor
2018-03-01
The almost inevitable descriptive statistics exercise that is undergone once data collection is complete, prior to inferential statistics, requires the acquisition of basic descriptors which may include standard deviation and quartiles. This paper provides pointers as to how to do this in Microsoft Excel™ and explains the relationship between the two. Copyright © 2018 Elsevier B.V. All rights reserved.
Validation Test Report for GDEM4
2010-08-19
standard deviations called the Generalized Digital Environmental Model ( GDEM ). The present document describes the development and evaluation of GDEM4...the newest version of GDEM . As part of the evaluation of GDEM4, comparisons are made in this report to GDEM3 and to four other ocean climatologies...depth climatology of temperature and salinity and their standard deviations called the Generalized Digital Environmental Model ( GDEM ). The history of
40 CFR 91.508 - Cumulative Sum (CumSum) procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... family may be determined to be in noncompliance for purposes of § 91.510. H = The Action Limit. It is 5.0 × σ, and is a function of the standard deviation, σ. σ = is the sample standard deviation and is... Equation must be final deteriorated test results as defined in § 91.509(c). Ci = max[0 0R (Ci-1 + Xi − (FEL...
NASA Astrophysics Data System (ADS)
Larsson, R.; Milz, M.; Rayer, P.; Saunders, R.; Bell, W.; Booton, A.; Buehler, S. A.; Eriksson, P.; John, V.
2015-10-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Same channel, there is 1.2 K in average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Same channel, there is 1.3 K in average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies causing up to ± 7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
NASA Astrophysics Data System (ADS)
Larsson, Richard; Milz, Mathias; Rayer, Peter; Saunders, Roger; Bell, William; Booton, Anna; Buehler, Stefan A.; Eriksson, Patrick; John, Viju O.
2016-03-01
We present a comparison of a reference and a fast radiative transfer model using numerical weather prediction profiles for the Zeeman-affected high-altitude Special Sensor Microwave Imager/Sounder channels 19-22. We find that the models agree well for channels 21 and 22 compared to the channels' system noise temperatures (1.9 and 1.3 K, respectively) and the expected profile errors at the affected altitudes (estimated to be around 5 K). For channel 22 there is a 0.5 K average difference between the models, with a standard deviation of 0.24 K for the full set of atmospheric profiles. Concerning the same channel, there is 1.2 K on average between the fast model and the sensor measurement, with 1.4 K standard deviation. For channel 21 there is a 0.9 K average difference between the models, with a standard deviation of 0.56 K. Regarding the same channel, there is 1.3 K on average between the fast model and the sensor measurement, with 2.4 K standard deviation. We consider the relatively small model differences as a validation of the fast Zeeman effect scheme for these channels. Both channels 19 and 20 have smaller average differences between the models (at below 0.2 K) and smaller standard deviations (at below 0.4 K) when both models use a two-dimensional magnetic field profile. However, when the reference model is switched to using a full three-dimensional magnetic field profile, the standard deviation to the fast model is increased to almost 2 K due to viewing geometry dependencies, causing up to ±7 K differences near the equator. The average differences between the two models remain small despite changing magnetic field configurations. We are unable to compare channels 19 and 20 to sensor measurements due to limited altitude range of the numerical weather prediction profiles. We recommended that numerical weather prediction software using the fast model takes the available fast Zeeman scheme into account for data assimilation of the affected sensor channels to better constrain the upper atmospheric temperatures.
Spectral combination of spherical gravitational curvature boundary-value problems
NASA Astrophysics Data System (ADS)
PitoÅák, Martin; Eshagh, Mehdi; Šprlák, Michal; Tenzer, Robert; Novák, Pavel
2018-04-01
Four solutions of the spherical gravitational curvature boundary-value problems can be exploited for the determination of the Earth's gravitational potential. In this article we discuss the combination of simulated satellite gravitational curvatures, i.e., components of the third-order gravitational tensor, by merging these solutions using the spectral combination method. For this purpose, integral estimators of biased- and unbiased-types are derived. In numerical studies, we investigate the performance of the developed mathematical models for the gravitational field modelling in the area of Central Europe based on simulated satellite measurements. Firstly, we verify the correctness of the integral estimators for the spectral downward continuation by a closed-loop test. Estimated errors of the combined solution are about eight orders smaller than those from the individual solutions. Secondly, we perform a numerical experiment by considering the Gaussian noise with the standard deviation of 6.5× 10-17 m-1s-2 in the input data at the satellite altitude of 250 km above the mean Earth sphere. This value of standard deviation is equivalent to a signal-to-noise ratio of 10. Superior results with respect to the global geopotential model TIM-r5 are obtained by the spectral downward continuation of the vertical-vertical-vertical component with the standard deviation of 2.104 m2s-2, but the root mean square error is the largest and reaches 9.734 m2s-2. Using the spectral combination of all gravitational curvatures the root mean square error is more than 400 times smaller but the standard deviation reaches 17.234 m2s-2. The combination of more components decreases the root mean square error of the corresponding solutions while the standard deviations of the combined solutions do not improve as compared to the solution from the vertical-vertical-vertical component. The presented method represents a weight mean in the spectral domain that minimizes the root mean square error of the combined solutions and improves standard deviation of the solution based only on the least accurate components.
NASA Astrophysics Data System (ADS)
Stier, P.; Schutgens, N. A. J.; Bellouin, N.; Bian, H.; Boucher, O.; Chin, M.; Ghan, S.; Huneeus, N.; Kinne, S.; Lin, G.; Ma, X.; Myhre, G.; Penner, J. E.; Randles, C. A.; Samset, B.; Schulz, M.; Takemura, T.; Yu, F.; Yu, H.; Zhou, C.
2013-03-01
Simulated multi-model "diversity" in aerosol direct radiative forcing estimates is often perceived as a measure of aerosol uncertainty. However, current models used for aerosol radiative forcing calculations vary considerably in model components relevant for forcing calculations and the associated "host-model uncertainties" are generally convoluted with the actual aerosol uncertainty. In this AeroCom Prescribed intercomparison study we systematically isolate and quantify host model uncertainties on aerosol forcing experiments through prescription of identical aerosol radiative properties in twelve participating models. Even with prescribed aerosol radiative properties, simulated clear-sky and all-sky aerosol radiative forcings show significant diversity. For a purely scattering case with globally constant optical depth of 0.2, the global-mean all-sky top-of-atmosphere radiative forcing is -4.47 Wm-2 and the inter-model standard deviation is 0.55 Wm-2, corresponding to a relative standard deviation of 12%. For a case with partially absorbing aerosol with an aerosol optical depth of 0.2 and single scattering albedo of 0.8, the forcing changes to 1.04 Wm-2, and the standard deviation increases to 1.01 W-2, corresponding to a significant relative standard deviation of 97%. However, the top-of-atmosphere forcing variability owing to absorption (subtracting the scattering case from the case with scattering and absorption) is low, with absolute (relative) standard deviations of 0.45 Wm-2 (8%) clear-sky and 0.62 Wm-2 (11%) all-sky. Scaling the forcing standard deviation for a purely scattering case to match the sulfate radiative forcing in the AeroCom Direct Effect experiment demonstrates that host model uncertainties could explain about 36% of the overall sulfate forcing diversity of 0.11 Wm-2 in the AeroCom Direct Radiative Effect experiment. Host model errors in aerosol radiative forcing are largest in regions of uncertain host model components, such as stratocumulus cloud decks or areas with poorly constrained surface albedos, such as sea ice. Our results demonstrate that host model uncertainties are an important component of aerosol forcing uncertainty that require further attention.
Quantifying the heterogeneity of the tectonic stress field using borehole data
Schoenball, Martin; Davatzes, Nicholas C.
2017-01-01
The heterogeneity of the tectonic stress field is a fundamental property which influences earthquake dynamics and subsurface engineering. Self-similar scaling of stress heterogeneities is frequently assumed to explain characteristics of earthquakes such as the magnitude-frequency relation. However, observational evidence for such scaling of the stress field heterogeneity is scarce.We analyze the local stress orientations using image logs of two closely spaced boreholes in the Coso Geothermal Field with sub-vertical and deviated trajectories, respectively, each spanning about 2 km in depth. Both the mean and the standard deviation of stress orientation indicators (borehole breakouts, drilling-induced fractures and petal-centerline fractures) determined from each borehole agree to the limit of the resolution of our method although measurements at specific depths may not. We find that the standard deviation in these boreholes strongly depends on the interval length analyzed, generally increasing up to a wellbore log length of about 600 m and constant for longer intervals. We find the same behavior in global data from the World Stress Map. This suggests that the standard deviation of stress indicators characterizes the heterogeneity of the tectonic stress field rather than the quality of the stress measurement. A large standard deviation of a stress measurement might be an expression of strong crustal heterogeneity rather than of an unreliable stress determination. Robust characterization of stress heterogeneity requires logs that sample stress indicators along a representative sample volume of at least 1 km.
[Effect strength variation in the single group pre-post study design: a critical review].
Maier-Riehle, B; Zwingmann, C
2000-08-01
In Germany, studies in rehabilitation research--in particular evaluation studies and examinations of quality of outcome--have so far mostly been executed according to the uncontrolled one-group pre-post design. Assessment of outcome is usually made by comparing the pre- and post-treatment means of the outcome variables. The pre-post differences are checked, and in case of significance, the results are increasingly presented in form of effect sizes. For this reason, this contribution presents different effect size indices used for the one-group pre-post design--in spite of fundamental doubts which exist in relation to that design due to its limited internal validity. The numerator concerning all effect size indices of the one-group pre-post design is defined as difference between the pre- and post-treatment means, whereas there are different possibilities and recommendations with regard to the denominator and hence the standard deviation that serves as the basis for standardizing the difference of the means. Used above all are standardization oriented towards the standard deviation of the pre-treatment scores, standardization oriented towards the pooled standard deviation of the pre- and post-treatment scores, and standardization oriented towards the standard deviation of the pre-post differences. Two examples are given to demonstrate that the different modes of calculating effect size indices in the one-group pre-post design may lead to very different outcome patterns. Additionally, it is pointed out that effect sizes from the uncontrolled one-group pre-post design generally tend to be higher than effect sizes from studies conducted with control groups. Finally, the pros and cons of the different effect size indices are discussed and recommendations are given.
Lenehan, Claire E.; Lewis, Simon W.
2002-01-01
LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10-10 to 5 × 10-6 M) with a line of best fit of y=1.05x+8.9164 (R2 =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8 M). The limit of detection (3σ) was determined as 5 × 10-11 M morphine. PMID:18924729
Lenehan, Claire E; Barnett, Neil W; Lewis, Simon W
2002-01-01
LabVIEW-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 x 10(-10) to 5 x 10(-6) M) with a line of best fit of y=1.05(x)+8.9164 (R(2) =0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 x 10(-8) M). The limit of detection (3sigma) was determined as 5 x 10(-11) M morphine.
Size-dependent standard deviation for growth rates: Empirical results and theoretical modeling
NASA Astrophysics Data System (ADS)
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H. Eugene; Grosse, I.
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation σ(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation σ(R) on the average value of the wages with a scaling exponent β≈0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation σ(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of σ(R) on the average payroll with a scaling exponent β≈-0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Pardo, Deborah; Jenouvrier, Stéphanie; Weimerskirch, Henri; Barbraud, Christophe
2017-06-19
Climate changes include concurrent changes in environmental mean, variance and extremes, and it is challenging to understand their respective impact on wild populations, especially when contrasted age-dependent responses to climate occur. We assessed how changes in mean and standard deviation of sea surface temperature (SST), frequency and magnitude of warm SST extreme climatic events (ECE) influenced the stochastic population growth rate log( λ s ) and age structure of a black-browed albatross population. For changes in SST around historical levels observed since 1982, changes in standard deviation had a larger (threefold) and negative impact on log( λ s ) compared to changes in mean. By contrast, the mean had a positive impact on log( λ s ). The historical SST mean was lower than the optimal SST value for which log( λ s ) was maximized. Thus, a larger environmental mean increased the occurrence of SST close to this optimum that buffered the negative effect of ECE. This 'climate safety margin' (i.e. difference between optimal and historical climatic conditions) and the specific shape of the population growth rate response to climate for a species determine how ECE affect the population. For a wider range in SST, both the mean and standard deviation had negative impact on log( λ s ), with changes in the mean having a greater effect than the standard deviation. Furthermore, around SST historical levels increases in either mean or standard deviation of the SST distribution led to a younger population, with potentially important conservation implications for black-browed albatrosses.This article is part of the themed issue 'Behavioural, ecological and evolutionary responses to extreme climatic events'. © 2017 The Author(s).
Assessment issues in the testing of children at school entry.
Rock, Donald A; Stenner, A Jackson
2005-01-01
The authors introduce readers to the research documenting racial and ethnic gaps in school readiness. They describe the key tests, including the Peabody Picture Vocabulary Test (PPVT), the Early Childhood Longitudinal Study (ECLS), and several intelligence tests, and describe how they have been administered to several important national samples of children. Next, the authors review the different estimates of the gaps and discuss how to interpret these differences. In interpreting test results, researchers use the statistical term "standard deviation" to compare scores across the tests. On average, the tests find a gap of about 1 standard deviation. The ECLS-K estimate is the lowest, about half a standard deviation. The PPVT estimate is the highest, sometimes more than 1 standard deviation. When researchers adjust those gaps statistically to take into account different outside factors that might affect children's test scores, such as family income or home environment, the gap narrows but does not disappear. Why such different estimates of the gap? The authors consider explanations such as differences in the samples, racial or ethnic bias in the tests, and whether the tests reflect different aspects of school "readiness," and conclude that none is likely to explain the varying estimates. Another possible explanation is the Spearman Hypothesis-that all tests are imperfect measures of a general ability construct, g; the more highly a given test correlates with g, the larger the gap will be. But the Spearman Hypothesis, too, leaves questions to be investigated. A gap of 1 standard deviation may not seem large, but the authors show clearly how it results in striking disparities in the performance of black and white students and why it should be of serious concern to policymakers.
Single-Station Sigma for the Iranian Strong Motion Stations
NASA Astrophysics Data System (ADS)
Zafarani, H.; Soghrat, M. R.
2017-11-01
In development of ground motion prediction equations (GMPEs), the residuals are assumed to have a log-normal distribution with a zero mean and a standard deviation, designated as sigma. Sigma has significant effect on evaluation of seismic hazard for designing important infrastructures such as nuclear power plants and dams. Both aleatory and epistemic uncertainties are involved in the sigma parameter. However, ground-motion observations over long time periods are not available at specific sites and the GMPEs have been derived using observed data from multiple sites for a small number of well-recorded earthquakes. Therefore, sigma is dominantly related to the statistics of the spatial variability of ground motion instead of temporal variability at a single point (ergodic assumption). The main purpose of this study is to reduce the variability of the residuals so as to handle it as epistemic uncertainty. In this regard, it is tried to partially apply the non-ergodic assumption by removing repeatable site effects from total variability of six GMPEs driven from the local, Europe-Middle East and worldwide data. For this purpose, we used 1837 acceleration time histories from 374 shallow earthquakes with moment magnitudes ranging from M w 4.0 to 7.3 recorded at 370 stations with at least two recordings per station. According to estimated single-station sigma for the Iranian strong motion stations, the ratio of event-corrected single-station standard deviation ( Φ ss) to within-event standard deviation ( Φ) is about 0.75. In other words, removing the ergodic assumption on site response resulted in 25% reduction of the within-event standard deviation that reduced the total standard deviation by about 15%.
Improving IQ measurement in intellectual disabilities using true deviation from population norms
2014-01-01
Background Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. Methods We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. Results We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Conclusion Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment. PMID:26491488
Size-dependent standard deviation for growth rates: empirical results and theoretical modeling.
Podobnik, Boris; Horvatic, Davor; Pammolli, Fabio; Wang, Fengzhong; Stanley, H Eugene; Grosse, I
2008-05-01
We study annual logarithmic growth rates R of various economic variables such as exports, imports, and foreign debt. For each of these variables we find that the distributions of R can be approximated by double exponential (Laplace) distributions in the central parts and power-law distributions in the tails. For each of these variables we further find a power-law dependence of the standard deviation sigma(R) on the average size of the economic variable with a scaling exponent surprisingly close to that found for the gross domestic product (GDP) [Phys. Rev. Lett. 81, 3275 (1998)]. By analyzing annual logarithmic growth rates R of wages of 161 different occupations, we find a power-law dependence of the standard deviation sigma(R) on the average value of the wages with a scaling exponent beta approximately 0.14 close to those found for the growth of exports, imports, debt, and the growth of the GDP. In contrast to these findings, we observe for payroll data collected from 50 states of the USA that the standard deviation sigma(R) of the annual logarithmic growth rate R increases monotonically with the average value of payroll. However, also in this case we observe a power-law dependence of sigma(R) on the average payroll with a scaling exponent beta approximately -0.08 . Based on these observations we propose a stochastic process for multiple cross-correlated variables where for each variable (i) the distribution of logarithmic growth rates decays exponentially in the central part, (ii) the distribution of the logarithmic growth rate decays algebraically in the far tails, and (iii) the standard deviation of the logarithmic growth rate depends algebraically on the average size of the stochastic variable.
Improving IQ measurement in intellectual disabilities using true deviation from population norms.
Sansone, Stephanie M; Schneider, Andrea; Bickel, Erika; Berry-Kravis, Elizabeth; Prescott, Christina; Hessl, David
2014-01-01
Intellectual disability (ID) is characterized by global cognitive deficits, yet the very IQ tests used to assess ID have limited range and precision in this population, especially for more impaired individuals. We describe the development and validation of a method of raw z-score transformation (based on general population norms) that ameliorates floor effects and improves the precision of IQ measurement in ID using the Stanford Binet 5 (SB5) in fragile X syndrome (FXS; n = 106), the leading inherited cause of ID, and in individuals with idiopathic autism spectrum disorder (ASD; n = 205). We compared the distributional characteristics and Q-Q plots from the standardized scores with the deviation z-scores. Additionally, we examined the relationship between both scoring methods and multiple criterion measures. We found evidence that substantial and meaningful variation in cognitive ability on standardized IQ tests among individuals with ID is lost when converting raw scores to standardized scaled, index and IQ scores. Use of the deviation z- score method rectifies this problem, and accounts for significant additional variance in criterion validation measures, above and beyond the usual IQ scores. Additionally, individual and group-level cognitive strengths and weaknesses are recovered using deviation scores. Traditional methods for generating IQ scores in lower functioning individuals with ID are inaccurate and inadequate, leading to erroneously flat profiles. However assessment of cognitive abilities is substantially improved by measuring true deviation in performance from standardization sample norms. This work has important implications for standardized test development, clinical assessment, and research for which IQ is an important measure of interest in individuals with neurodevelopmental disorders and other forms of cognitive impairment.
Validation of 10 years of SAO OMI Ozone Profiles with Ozonesonde and MLS Observations
NASA Astrophysics Data System (ADS)
Huang, G.; Liu, X.; Chance, K.; Bhartia, P. K.
2015-12-01
To evaluate the accuracy and long-term stability of the SAO OMI ozone profile product, we validate ~10 years of ozone profile product (Oct. 2004-Dec. 2014) against collocated ozonesonde and MLS data. Ozone profiles as well stratospheric, tropospheric, lower tropospheric ozone columns are compared with ozonesonde data for different latitude bands, and time periods (e.g., 2004-2008/2009-2014 for without/with row anomaly. The mean biases and their standard deviations are also assessed as a function of time to evaluate the long-term stability and bias trends. In the mid-latitude and tropical regions, OMI generally shows good agreement with ozonesonde observations. The mean ozone profile biases are generally within 6% with up to 30% standard deviations. The biases of stratospheric ozone columns (SOC) and tropospheric ozone columns (TOC) are -0.3%-2.2% and -0.2%-3%, while standard deviations are 3.9%-5.8% and 14.4%-16.0%, respectively. However, the retrievals during 2009-2014 show larger standard deviations and larger temporal variations; the standard deviations increase by ~5% in the troposphere and ~2% in the stratosphere. Retrieval biases at individual levels in the stratosphere and upper troposphere show statistically significant trends and different trends for 2004-2008 and 2009-2014 periods. The trends in integrated ozone partial columns are less significant due to cancellation from various layers, except for significant trend in tropical SOC. These results suggest the need to perform time dependent radiometric calibration to maintain the long-term stability of this product. Similarly, we are comparing the OMI stratospheric ozone profiles and SOC with collocated MLS data, and the results will be reported.
Revert Ventura, A J; Sanz Requena, R; Martí-Bonmatí, L; Pallardó, Y; Jornet, J; Gaspar, C
2014-01-01
To study whether the histograms of quantitative parameters of perfusion in MRI obtained from tumor volume and peritumor volume make it possible to grade astrocytomas in vivo. We included 61 patients with histological diagnoses of grade II, III, or IV astrocytomas who underwent T2*-weighted perfusion MRI after intravenous contrast agent injection. We manually selected the tumor volume and peritumor volume and quantified the following perfusion parameters on a voxel-by-voxel basis: blood volume (BV), blood flow (BF), mean transit time (TTM), transfer constant (K(trans)), washout coefficient, interstitial volume, and vascular volume. For each volume, we obtained the corresponding histogram with its mean, standard deviation, and kurtosis (using the standard deviation and kurtosis as measures of heterogeneity) and we compared the differences in each parameter between different grades of tumor. We also calculated the mean and standard deviation of the highest 10% of values. Finally, we performed a multiparametric discriminant analysis to improve the classification. For tumor volume, we found statistically significant differences among the three grades of tumor for the means and standard deviations of BV, BF, and K(trans), both for the entire distribution and for the highest 10% of values. For the peritumor volume, we found no significant differences for any parameters. The discriminant analysis improved the classification slightly. The quantification of the volume parameters of the entire region of the tumor with BV, BF, and K(trans) is useful for grading astrocytomas. The heterogeneity represented by the standard deviation of BF is the most reliable diagnostic parameter for distinguishing between low grade and high grade lesions. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
NASA Astrophysics Data System (ADS)
Schupp, C. A.; McNinch, J. E.; List, J. H.; Farris, A. S.
2002-12-01
The formation and behavior of hotspots, or sections of the beach that exhibit markedly higher shoreline change rates than adjacent regions, are poorly understood. Several hotspots have been identified on the Outer Banks, a developed barrier island in North Carolina. To better understand hotspot dynamics and the potential relationship to the geologic framework in which they occur, the surf zone between Duck and Bodie Island was surveyed in June 2002 as part of a research effort supported by the U.S. Geological Survey and U.S. Army Corps of Engineers. Swath bathymetry, sidescan sonar, and chirp seismic were used to characterize a region 40 km long and1 km wide. Hotspot locations were pinpointed using standard deviation values for shoreline position as determined by monthly SWASH buggy surveys of the mean high water contour between October 1999 and September 2002. Observational data and sidescan images were mapped to delineate regions of surficial sediment distributions, and regions of interest were ground-truthed via grab samples or visual inspection. General kilometer-scale correlation between acoustic backscatter and high shoreline standard deviation is evident. Acoustic returns are uniform in a region of Duck where standard deviation is low, but backscatter is patchy around the Kitty Hawk hotspot, where standard deviation is higher. Based on ground-truthing of an area further north, these patches are believed to be an older ravinement surface of fine sediment. More detailed analyses of the correlation between acoustic data, standard deviation, and hotspot locations will be presented. Future work will include integration of seismic, bathymetric, and sidescan data to better understand the links between sub-bottom geology, temporal changes in surficial sediments, surf-zone sediment budgets, and short-term changes in shoreline position and morphology.
Determination of ammonium in a buddingtonite sample by ion-chromatography
Klock, P.R.; Lamothe, P.J.
1986-01-01
An ion-chromatographic method for the direct determination of ammonium, potassium, and sodium in geologic materials is described. Samples are decomposed with a mixture of hydrofluoric and hydrochloric acids in a sealed polycarbonate bottle heated in a microwave oven. The ion-chromatograph separates the cations and determines them by conductivity measurement. The ammonium concentrations thus determined have been verified by use of an ammonia-specific electrode. A total of 32 analyses of ammonium salts by both techniques showed an average error of -4%, with a relative standard deviation (RSD) of 6%. The ammonium concentrations found in a buddingtonite sample had an RSD of 2.2% and their mean agreed with that obtained by the Kjeldahl method. By use of the prescribed dilution of the sample, detection limits of 0.1% can be achieved for all three cations. ?? 1986.
Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D
2012-02-01
The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.
Plasma Insulin Levels and Hypoglycemia Affect Subcutaneous Interstitial Glucose Concentration.
Moscardó, Vanessa; Bondia, Jorge; Ampudia-Blasco, Francisco J; Fanelli, Carmine G; Lucidi, Paola; Rossetti, Paolo
2018-04-01
Continuous glucose monitoring (CGM) accuracy during hypoglycemia is suboptimal. This might be partly explained by insulin or hypoglycemia-induced changes in the plasma interstitial subcutaneous (SC) fluid glucose gradient. The aim of the present study was to assess the role of plasma insulin (PI) and hypoglycemia itself in the plasma and interstitial SC fluid glucose concentration in patients with type 1 diabetes mellitus. Eleven subjects with type 1 diabetes (age 36.5 ± 9.1 years, HbA 1c 7.9 ± 0.4% [62.8 ± 2.02 mmol/mol]; mean ± standard deviation) were evaluated under hyperinsulinemic euglycemia and hypoglycemia. Each subject underwent two randomized crossover clamps with either a primed 0.3 (low insulin) or 1 mU/(kg·min) (high insulin) insulin infusion. The raw CGM signal was normalized with median preclamp values to obtain a standardized measure of the interstitial glucose (IG) concentration before statistical analysis. The mean PI concentration was greater in high insulin studies (HISs) versus low insulin studies (LISs) (412.89 ± 13.63 vs. 177.22 ± 10.05 pmol/L). During hypoglycemia, glucagon, adrenaline, free fatty acids, glycerol, and beta-OH-butyrate were higher in the LIS (P < 0.0001). Likewise, the IG concentration was significantly different (P < 0.0001). This was due to lower IG concentration than plasma glucose (PG) concentration during the euglycemic hyperinsulinemic phases in the HIS. In contrast, no difference was observed during hypoglycemia. This was the result of an unchanged PG/IG gradient during the entire LIS, while in the HIS, this gradient increased during the hyperinsulinemic euglycemia phase. Both PI levels and hypoglycemia affect the relationship between IG and PG concentration. ClinicalTrials.gov Identifier: NCT01714895.
Day, Russel D.; Vander Pol, Stacy S.; Christopher, Steven J.; Davis, W.C.; Pugh, Rebecca S.; Simac, K.S.; Roseneau, David G.; Becker, P.R.
2006-01-01
Sixty common murre (Uria aalge) and 27 thick-billed murre (Uria lomvia) eggs collected by the Seabird Tissue Archival and Monitoring Project (STAMP) in 1999−2001 from two Gulf of Alaska and three Bering Sea nesting colonies were analyzed for total mercury (Hg) using isotope dilution cold vapor inductively coupled mass spectrometry. Hg concentrations (wet mass) ranged from 0.011 μg/g to 0.357 μg/g (relative standard deviation = 76%), while conspecifics from the same colonies and years had an average relative standard deviation of 33%. Hg levels in eggs from the Gulf of Alaska (0.166 μg/g ± 0.011 μg/g) were significantly higher (p < 0.0001) than in the Bering Sea (0.047 μg/g ± 0.004 μg/g). Within the Bering Sea, Hg was significantly higher (p = 0.0007) in eggs from Little Diomede Island near the arctic than at the two more southern colonies. Although thick-billed and common murres are ecologically similar, there were significant species differences in egg Hg concentrations within each region (p < 0.0001). In the Bering Sea, eggs from thick-billed murres had higher Hg concentrations than eggs from common murres, while in the Gulf of Alaska, common murre eggs had higher concentrations than those of thick-billed murres. A separate one-way analysis of variance on the only time−trend data currently available for a colony (St. Lazaria Island in the Gulf of Alaska) found significantly lower Hg concentrations in common murre eggs collected in 2001 compared to 1999 (p = 0.017). Results from this study indicate that murre eggs may be effective monitoring units for detecting geographic, species, and temporal patterns of Hg contamination in marine food webs. The relatively small intracolony variation in egg Hg levels and the ability to consistently obtain adequate sample sizes both within and among colonies over a large geographic range means that monitoring efforts using murre eggs will have suitable statistical power for detecting environmental patterns of Hg contamination. The potential influences of trophic effects, physical transport patterns, and biogeochemical processes on these monitoring efforts are discussed, and future plans to investigate the sources of the observed variability are presented.
NASA Astrophysics Data System (ADS)
Thariyan, Mathew Paul
Dual-pump coherent anti-Stokes Raman scattering (DP-CARS) temperature and major species (CO2/N2) concentration measurements have been performed in an optically-accessible high-pressure gas turbine combustor facility (GTCF) and for partially-premixed and non-premixed flames in a laminar counter-flow burner. A window assembly incorporating pairs of thin and thick fused silica windows on three sides was designed, fabricated, and assembled in the GTCF for advanced laser diagnostic studies. An injection-seeded optical parametric oscillator (OPO) was used as a narrowband pump laser source in the dual-pump CARS system. Large prisms on computer-controlled translation stages were used to direct the CARS beams either into the main optics leg for measurements in the GTCF or to a reference optics leg for measurements of the nonresonant CARS spectrum and for aligning the CARS system. Combusting flows were stabilized with liquid fuel injection only for the central injector of a 9-element lean direct injection (LDI) device developed at NASA Glenn Research Center. The combustor was operated using Jet A fuel at inlet air temperatures up to 725 K and combustor pressures up to 1.03 MPa. Single-shot DP-CARS spectra were analyzed using the Sandia CARSFT code in the batch operation mode to yield instantaneous temperature and CO2/N2 concentration ratio values. Spatial maps of mean and standard deviations of temperature and CO2/N2 concentrations were obtained in the high-pressure LDI flames by translating the CARS probe volume in axial and vertical directions inside the combustor rig. The mean temperature fields demonstrate the effect of the combustor conditions on the overall flame length and the average flame structure. The temperature relative standard deviation values indicate thermal fluctuations due to the presence of recirculation zones and/or flame brush fluctuations. The correlation between the temperature and relative CO 2 concentration data has been studied at various combustor conditions. The insight into the reacting flow structure provided by these measurements is discussed. Such measurements at conditions similar to those of aircraft gas turbine combustors are extremely useful for testing combustion models being used to predict performance of these systems.
Lutka, Anna; Maruszewska, Małgorzata
2011-01-01
It were established and validated the conditions of voltammetric determination of copper in pharmaceutical preparations. The three selected preparations: Zincuprim (A), Wapń, cynk, miedź z wit. C (B), Vigor complete (V) contained different salts and different quantity of copper (II) and increasing number of accompanied ingredients. For the purpose to transfer copper into solution, the samples of powdered tablets of the first and second preparation were undergone extraction and of the third the mineralization procedures. The concentration of copper in solution was determined by differential pulse voltammetry (DP) using comparison with standard technique. In the validation process, the selectivity, accuracy, precision and linearity of DP determination of copper in three preparations were estimated. Copper was determined within the concentration range of 1-9 ppm (1-9 microg/mL): the mean recoveries approached 102% (A), 100% (B), 102% (V); the relative standard deviations of determinations (RSD) were 0.79-1.59% (A), 0.62-0.85% (B) and 1.68-2.28% (V), respectively. The mean recoveries and the RSDs of determination satisfied the requirements for the analyte concentration at the level 1-10 ppm. The statistical verification confirmed that the tested voltammetric method is suitable for determination of copper in pharmaceutical preparation.
Gomes Neto, J A; Zara, L F; Rocha, J C; Santos, A; Dakuzaku, C S; Nóbrega, J A
2000-03-06
A flow-injection system with a Chelite-S(R) cationic resin packed minicolumn is proposed for the determination of trace levels of mercury in agroindustrial samples by cold vapor atomic absorption spectrometry. Improved sensitivity and selectivity are attained since mercuric ions are on-line concentrated whereas other potential interferents are discarded. With on-line reductive elution procedure, concentrated hydrochloric acid could be replaced by 10% w/v SnCl(2), in 6 M HCl as eluent. The reversed-intermittent stream either carries the atomic mercury to the flow cell in the forward direction or removes the residue from reactor/gas-liquid separator to a discarding flask in the opposite direction. Concentration and volume of reagent, acidity, flow rates, commutation times and potential interfering species were investigated. For 120 s preconcentration time, the proposed system handles about 25 samples h(-1) (50.0-500 ng l(-1)), consuming about 10 ml sample and 5 mg SnCl(2) per determination. The detection limit is 0.8 ng l(-1) and the relative standard deviation (RSD) (n=12) of a 76.7 ng l(-1) sample is about 5%. Results are in agreement with certified value of standard materials at 95% confidence level and good recoveries (97-128%) of spiked samples were found.
Preliminary analysis of hot spot factors in an advanced reactor for space electric power systems
NASA Technical Reports Server (NTRS)
Lustig, P. H.; Holms, A. G.; Davison, H. W.
1973-01-01
The maximum fuel pin temperature for nominal operation in an advanced power reactor is 1370 K. Because of possible nitrogen embrittlement of the clad, the fuel temperature was limited to 1622 K. Assuming simultaneous occurrence of the most adverse conditions a deterministic analysis gave a maximum fuel temperature of 1610 K. A statistical analysis, using a synthesized estimate of the standard deviation for the highest fuel pin temperature, showed probabilities of 0.015 of that pin exceeding the temperature limit by the distribution free Chebyshev inequality and virtually nil assuming a normal distribution. The latter assumption gives a 1463 K maximum temperature at 3 standard deviations, the usually assumed cutoff. Further, the distribution and standard deviation of the fuel-clad gap are the most significant contributions to the uncertainty in the fuel temperature.
Influence of eye micromotions on spatially resolved refractometry
NASA Astrophysics Data System (ADS)
Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Osipova, Irina Y.
2001-01-01
The influence eye micromotions on the accuracy of estimation of Zernike coefficients form eye transverse aberration measurements was investigated. By computer modeling, the following found eye aberrations have been examined: defocusing, primary astigmatism, spherical aberration of the 3rd and the 5th orders, as well as their combinations. It was determined that the standard deviation of estimated Zernike coefficients is proportional to the standard deviation of angular eye movements. Eye micromotions cause the estimation errors of Zernike coefficients of present aberrations and produce the appearance of Zernike coefficients of aberrations, absent in the eye. When solely defocusing is present, the biggest errors, cased by eye micromotions, are obtained for aberrations like coma and astigmatism. In comparison with other aberrations, spherical aberration of the 3rd and the 5th orders evokes the greatest increase of the standard deviation of other Zernike coefficients.
Barth, Nancy A.; Veilleux, Andrea G.
2012-01-01
The U.S. Geological Survey (USGS) is currently updating at-site flood frequency estimates for USGS streamflow-gaging stations in the desert region of California. The at-site flood-frequency analysis is complicated by short record lengths (less than 20 years is common) and numerous zero flows/low outliers at many sites. Estimates of the three parameters (mean, standard deviation, and skew) required for fitting the log Pearson Type 3 (LP3) distribution are likely to be highly unreliable based on the limited and heavily censored at-site data. In a generalization of the recommendations in Bulletin 17B, a regional analysis was used to develop regional estimates of all three parameters (mean, standard deviation, and skew) of the LP3 distribution. A regional skew value of zero from a previously published report was used with a new estimated mean squared error (MSE) of 0.20. A weighted least squares (WLS) regression method was used to develop both a regional standard deviation and a mean model based on annual peak-discharge data for 33 USGS stations throughout California’s desert region. At-site standard deviation and mean values were determined by using an expected moments algorithm (EMA) method for fitting the LP3 distribution to the logarithms of annual peak-discharge data. Additionally, a multiple Grubbs-Beck (MGB) test, a generalization of the test recommended in Bulletin 17B, was used for detecting multiple potentially influential low outliers in a flood series. The WLS regression found that no basin characteristics could explain the variability of standard deviation. Consequently, a constant regional standard deviation model was selected, resulting in a log-space value of 0.91 with a MSE of 0.03 log units. Yet drainage area was found to be statistically significant at explaining the site-to-site variability in mean. The linear WLS regional mean model based on drainage area had a Pseudo- 2 R of 51 percent and a MSE of 0.32 log units. The regional parameter estimates were then used to develop a set of equations for estimating flows with 50-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities for ungaged basins. The final equations are functions of drainage area.Average standard errors of prediction for these regression equations range from 214.2 to 856.2 percent.
Khachatryan, Vardan
2015-08-27
A first search is reported for a standard model Higgs boson (H) that is produced through vector boson fusion and decays to a bottom-quark pair. Two data samples, corresponding to integrated luminosities of 19.8 fb -1 and 18.3 fb -1 of proton-proton collisions at √s=8 TeV were selected for this channel at the CERN LHC. The observed significance in these data samples for a H→more » $$\\mathrm{b\\bar{b}}$$ signal at a mass of 125 GeV is 2.2 standard deviations, while the expected significance is 0.8 standard deviations. The fitted signal strength μ=σ/σ SM=2.8 +1.6 -1.4. The combination of this result with other CMS searches for the Higgs boson decaying to a b-quark pair yields a signal strength of 1.0±0.4, corresponding to a signal significance of 2.6 standard deviations for a Higgs boson mass of 125 GeV.« less
Zarbo, Richard J; Copeland, Jacqueline R; Varney, Ruan C
2017-10-01
To develop a business subsystem fulfilling International Organization for Standardization 15189 nonconformance management regulatory standard, facilitating employee engagement in problem identification and resolution to effect quality improvement and risk mitigation. From 2012 to 2016, the integrated laboratories of the Henry Ford Health System used a quality technical team to develop and improve a management subsystem designed to identify, track, trend, and summarize nonconformances based on frequency, risk, and root cause for elimination at the level of the work. Programmatic improvements and training resulted in markedly increased documentation culminating in 71,641 deviations in 2016 classified by a taxonomy of 281 defect types into preanalytic (74.8%), analytic (23.6%), and postanalytic (1.6%) testing phases. The top 10 deviations accounted for 55,843 (78%) of the total. Deviation management is a key subsystem of managers' standard work whereby knowledge of nonconformities assists in directing corrective actions and continuous improvements that promote consistent execution and higher levels of performance. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
U.S. Navy Marine Climatic Atlas of the World. Volume IX. World-Wide Means and Standard Deviations
1981-10-01
TITLE (..d SobtII,) S. TYPE OF REPORT & PERIOD COVERED U. S. Navy Marine Climatic Atlas of the World Volume IX World-wide Means and Standard Reference...Ives the best estimate of the population standard deviations. The means, , are com~nuted from: EX IIN I 90 80 70 60" 50’ 40, 30 20 10 0 1070 T- VErr ...or 10%, whichever is greater Since the mean ice limit approximates the minus two de l temperature isopleth, this analyzed lower limit was Wave Heights
The normalization of deviance in healthcare delivery
Banja, John
2009-01-01
Many serious medical errors result from violations of recognized standards of practice. Over time, even egregious violations of standards of practice may become “normalized” in healthcare delivery systems. This article describes what leads to this normalization and explains why flagrant practice deviations can persist for years, despite the importance of the standards at issue. This article also provides recommendations to aid healthcare organizations in identifying and managing unsafe practice deviations before they become normalized and pose genuine risks to patient safety, quality care, and employee morale. PMID:20161685
Observation of the Higgs boson decay to a pair of τ leptons with the CMS detector
NASA Astrophysics Data System (ADS)
Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Ambrogi, F.; Asilar, E.; Bergauer, T.; Brandstetter, J.; Brondolin, E.; Dragicevic, M.; Erö, J.; Flechl, M.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Grossmann, J.; Hrubec, J.; Jeitler, M.; König, A.; Krammer, N.; Krätschmer, I.; Liko, D.; Madlener, T.; Mikulec, I.; Pree, E.; Rabady, D.; Rad, N.; Rohringer, H.; Schieck, J.; Schöfbeck, R.; Spanring, M.; Spitzbart, D.; Waltenberger, W.; Wittmann, J.; Wulz, C.-E.; Zarucki, M.; Chekhovsky, V.; Mossolov, V.; Suarez Gonzalez, J.; De Wolf, E. A.; Di Croce, D.; Janssen, X.; Lauwers, J.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Abu Zeid, S.; Blekman, F.; D'Hondt, J.; De Bruyn, I.; De Clercq, J.; Deroover, K.; Flouris, G.; Lontkovskyi, D.; Lowette, S.; Moortgat, S.; Moreels, L.; Python, Q.; Skovpen, K.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Parijs, I.; Beghin, D.; Brun, H.; Clerbaux, B.; De Lentdecker, G.; Delannoy, H.; Fasanella, G.; Favart, L.; Goldouzian, R.; Grebenyuk, A.; Karapostoli, G.; Lenzi, T.; Luetic, J.; Maerschalk, T.; Marinov, A.; Randle-conde, A.; Seva, T.; Vander Velde, C.; Vanlaer, P.; Vannerom, D.; Yonamine, R.; Zenoni, F.; Zhang, F.; Cimmino, A.; Cornelis, T.; Dobur, D.; Fagot, A.; Gul, M.; Khvastunov, I.; Poyraz, D.; Roskas, C.; Salva, S.; Tytgat, M.; Verbeke, W.; Zaganidis, N.; Bakhshiansohi, H.; Bondu, O.; Brochet, S.; Bruno, G.; Caputo, C.; Caudron, A.; De Visscher, S.; Delaere, C.; Delcourt, M.; Francois, B.; Giammanco, A.; Jafari, A.; Komm, M.; Krintiras, G.; Lemaitre, V.; Magitteri, A.; Mertens, A.; Musich, M.; Piotrzkowski, K.; Quertenmont, L.; Vidal Marono, M.; Wertz, S.; Beliy, N.; Aldá Júnior, W. L.; Alves, F. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Hensel, C.; Moraes, A.; Pol, M. E.; Rebello Teles, P.; Belchior Batista Das Chagas, E.; Carvalho, W.; Chinellato, J.; Coelho, E.; Custódio, A.; Da Costa, E. M.; Da Silveira, G. G.; De Jesus Damiao, D.; Fonseca De Souza, S.; Huertas Guativa, L. M.; Malbouisson, H.; Melo De Almeida, M.; Mora Herrera, C.; Mundim, L.; Nogima, H.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Torres Da Silva De Araujo, F.; Vilela Pereira, A.; Ahuja, S.; Bernardes, C. A.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Romero Abad, D.; Ruiz Vargas, J. C.; Aleksandrov, A.; Hadjiiska, R.; Iaydjiev, P.; Misheva, M.; Rodozov, M.; Shopova, M.; Stoykova, S.; Sultanov, G.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Fang, W.; Gao, X.; Ahmad, M.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Chen, Y.; Jiang, C. H.; Leggat, D.; Liao, H.; Liu, Z.; Romeo, F.; Shaheen, S. M.; Spiezia, A.; Tao, J.; Wang, C.; Wang, Z.; Yazgan, E.; Zhang, H.; Zhang, S.; Zhao, J.; Ban, Y.; Chen, G.; Li, Q.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; González Hernández, C. F.; Ruiz Alvarez, J. D.; Courbon, B.; Godinovic, N.; Lelas, D.; Puljak, I.; Ribeiro Cipriano, P. M.; Sculac, T.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Ferencek, D.; Kadija, K.; Mesic, B.; Starodumov, A.; Susa, T.; Ather, M. W.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Finger, M.; Finger, M.; Carrera Jarrin, E.; Assran, Y.; Elgammal, S.; Mahrous, A.; Dewanjee, R. K.; Kadastik, M.; Perrini, L.; Raidal, M.; Tiko, A.; Veelken, C.; Eerola, P.; Pekkanen, J.; Voutilainen, M.; Härkönen, J.; Järvinen, T.; Karimäki, V.; Kinnunen, R.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Faure, J. L.; Ferri, F.; Ganjour, S.; Ghosh, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Kucher, I.; Locci, E.; Machet, M.; Malcles, J.; Negro, G.; Rander, J.; Rosowsky, A.; Sahin, M. Ö.; Titov, M.; Abdulsalam, A.; Amendola, C.; Antropov, I.; Baffioni, S.; Beaudette, F.; Busson, P.; Cadamuro, L.; Charlot, C.; Granier de Cassagnac, R.; Jo, M.; Lisniak, S.; Lobanov, A.; Martin Blanco, J.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Pigard, P.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Stahl Leiton, A. G.; Strebler, T.; Yilmaz, Y.; Zabi, A.; Zghiche, A.; Agram, J.-L.; Andrea, J.; Bloch, D.; Brom, J.-M.; Buttignol, M.; Chabert, E. C.; Chanon, N.; Collard, C.; Conte, E.; Coubez, X.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Jansová, M.; Le Bihan, A.-C.; Tonon, N.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Bernet, C.; Boudoul, G.; Chierici, R.; Contardo, D.; Depasse, P.; El Mamouni, H.; Fay, J.; Finco, L.; Gascon, S.; Gouzevitch, M.; Grenier, G.; Ille, B.; Lagarde, F.; Laktineh, I. B.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Popov, A.; Sordini, V.; Vander Donckt, M.; Viret, S.; Khvedelidze, A.; Tsamalaidze, Z.; Autermann, C.; Feld, L.; Kiesel, M. K.; Klein, K.; Lipinski, M.; Preuten, M.; Schomakers, C.; Schulz, J.; Verlage, T.; Zhukov, V.; Albert, A.; Dietz-Laursonn, E.; Duchardt, D.; Endres, M.; Erdmann, M.; Erdweg, S.; Esch, T.; Fischer, R.; Güth, A.; Hamer, M.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Knutzen, S.; Merschmeyer, M.; Meyer, A.; Millet, P.; Mukherjee, S.; Pook, T.; Radziej, M.; Reithler, H.; Rieger, M.; Scheuch, F.; Teyssier, D.; Thüer, S.; Flügge, G.; Kargoll, B.; Kress, T.; Künsken, A.; Lingemann, J.; Müller, T.; Nehrkorn, A.; Nowack, A.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Arndt, T.; Asawatangtrakuldee, C.; Beernaert, K.; Behnke, O.; Behrens, U.; Bermúdez Martínez, A.; Bin Anuar, A. A.; Borras, K.; Botta, V.; Campbell, A.; Connor, P.; Contreras-Campana, C.; Costanza, F.; Diez Pardos, C.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Eren, E.; Gallo, E.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Grados Luyando, J. M.; Grohsjean, A.; Gunnellini, P.; Guthoff, M.; Harb, A.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Kasemann, M.; Keaveney, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Lelek, A.; Lenz, T.; Leonard, J.; Lipka, K.; Lohmann, W.; Mankel, R.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Ntomari, E.; Pitzl, D.; Raspereza, A.; Roland, B.; Savitskyi, M.; Saxena, P.; Shevchenko, R.; Spannagel, S.; Stefaniuk, N.; Van Onsem, G. P.; Walsh, R.; Wen, Y.; Wichmann, K.; Wissing, C.; Zenaiev, O.; Bein, S.; Blobel, V.; Centis Vignali, M.; Dreyer, T.; Garutti, E.; Gonzalez, D.; Haller, J.; Hinzmann, A.; Hoffmann, M.; Karavdina, A.; Klanner, R.; Kogler, R.; Kovalchuk, N.; Kurz, S.; Lapsien, T.; Marchesini, I.; Marconi, D.; Meyer, M.; Niedziela, M.; Nowatschin, D.; Pantaleo, F.; Peiffer, T.; Perieanu, A.; Scharf, C.; Schleper, P.; Schmidt, A.; Schumann, S.; Schwandt, J.; Sonneveld, J.; Stadie, H.; Steinbrück, G.; Stober, F. M.; Stöver, M.; Tholen, H.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Vormwald, B.; Akbiyik, M.; Barth, C.; Baur, S.; Butz, E.; Caspart, R.; Chwalek, T.; Colombo, F.; De Boer, W.; Dierlamm, A.; Freund, B.; Friese, R.; Giffels, M.; Haitz, D.; Hartmann, F.; Heindl, S. M.; Husemann, U.; Kassel, F.; Kudella, S.; Mildner, H.; Mozer, M. U.; Müller, Th.; Plagge, M.; Quast, G.; Rabbertz, K.; Schröder, M.; Shvetsov, I.; Sieber, G.; Simonis, H. J.; Ulrich, R.; Wayand, S.; Weber, M.; Weiler, T.; Williamson, S.; Wöhrmann, C.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Topsis-Giotis, I.; Karathanasis, G.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Kousouris, K.; Evangelou, I.; Foudas, C.; Kokkas, P.; Mallios, S.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Triantis, F. A.; Csanad, M.; Filipovic, N.; Pasztor, G.; Veres, G. I.; Bencze, G.; Hajdu, C.; Horvath, D.; Hunyadi, Á.; Sikler, F.; Veszpremi, V.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Makovec, A.; Molnar, J.; Szillasi, Z.; Bartók, M.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Choudhury, S.; Komaragiri, J. R.; Bahinipati, S.; Bhowmik, S.; Mal, P.; Mandal, K.; Nayak, A.; Sahoo, D. K.; Sahoo, N.; Swain, S. K.; Bansal, S.; Beri, S. B.; Bhatnagar, V.; Chawla, R.; Dhingra, N.; Kalsi, A. K.; Kaur, A.; Kaur, M.; Kumar, R.; Kumari, P.; Mehta, A.; Singh, J. B.; Walia, G.; Kumar, Ashok; Shah, Aashaq; Bhardwaj, A.; Chauhan, S.; Choudhary, B. C.; Garg, R. B.; Keshri, S.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, R.; Bhardwaj, R.; Bhattacharya, R.; Bhattacharya, S.; Bhawandeep, U.; Dey, S.; Dutt, S.; Dutta, S.; Ghosh, S.; Majumdar, N.; Modak, A.; Mondal, K.; Mukhopadhyay, S.; Nandan, S.; Purohit, A.; Roy, A.; Roy, D.; Roy Chowdhury, S.; Sarkar, S.; Sharan, M.; Thakur, S.; Behera, P. K.; Chudasama, R.; Dutta, D.; Jha, V.; Kumar, V.; Mohanty, A. K.; Netrakanti, P. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Dugad, S.; Mahakud, B.; Mitra, S.; Mohanty, G. B.; Sur, N.; Sutar, B.; Banerjee, S.; Bhattacharya, S.; Chatterjee, S.; Das, P.; Guchait, M.; Jain, Sa.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Sarkar, T.; Wickramage, N.; Chauhan, S.; Dube, S.; Hegde, V.; Kapoor, A.; Kothekar, K.; Pandey, S.; Rane, A.; Sharma, S.; Chenarani, S.; Eskandari Tadavani, E.; Etesami, S. M.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Errico, F.; Fiore, L.; Iaselli, G.; Lezki, S.; Maggi, G.; Maggi, M.; Miniello, G.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Ranieri, A.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Battilana, C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Chhibra, S. S.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Albergo, S.; Costa, S.; Di Mattia, A.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Chatterjee, K.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Lenzi, P.; Meschini, M.; Paoletti, S.; Russo, L.; Sguazzoni, G.; Strom, D.; Viliani, L.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Primavera, F.; Calvelli, V.; Ferro, F.; Robutti, E.; Tosi, S.; Benaglia, A.; Brianza, L.; Brivio, F.; Ciriolo, V.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Ghezzi, A.; Govoni, P.; Malberti, M.; Malvezzi, S.; Manzoni, R. A.; Menasce, D.; Moroni, L.; Paganoni, M.; Pauwels, K.; Pedrini, D.; Pigazzini, S.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Fienga, F.; Iorio, A. O. M.; Khan, W. A.; Lista, L.; Meola, S.; Paolucci, P.; Sciacca, C.; Thyssen, F.; Azzi, P.; Bacchetta, N.; Benato, L.; Bisello, D.; Boletti, A.; Bragagnolo, A.; Carlin, R.; Carvalho Antunes De Oliveira, A.; Checchia, P.; Dall'Osso, M.; De Castro Manzano, P.; Dorigo, T.; Dosselli, U.; Gasparini, F.; Gasparini, U.; Lacaprara, S.; Lujan, P.; Margoni, M.; Meneguzzo, A. T.; Pozzobon, N.; Ronchese, P.; Rossin, R.; Simonetto, F.; Torassa, E.; Ventura, S.; Zanetti, M.; Zotto, P.; Braghieri, A.; Magnani, A.; Montagna, P.; Ratti, S. P.; Re, V.; Ressegotti, M.; Riccardi, C.; Salvini, P.; Vai, I.; Vitulo, P.; Alunni Solestizi, L.; Biasini, M.; Bilei, G. M.; Cecchi, C.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Leonardi, R.; Manoni, E.; Mantovani, G.; Mariani, V.; Menichelli, M.; Rossi, A.; Santocchia, A.; Spiga, D.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Boccali, T.; Borrello, L.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Fedi, G.; Giannini, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Manca, E.; Mandorli, G.; Martini, L.; Messineo, A.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Spagnolo, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Barone, L.; Cavallari, F.; Cipriani, M.; Daci, N.; Del Re, D.; Di Marco, E.; Diemoz, M.; Gelli, S.; Longo, E.; Margaroli, F.; Marzocchi, B.; Meridiani, P.; Organtini, G.; Paramatti, R.; Preiato, F.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bartosik, N.; Bellan, R.; Biino, C.; Cartiglia, N.; Cenna, F.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Kiani, B.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Monteil, E.; Monteno, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Ravera, F.; Romero, A.; Ruspa, M.; Sacchi, R.; Shchelina, K.; Sola, V.; Solano, A.; Staiano, A.; Traczyk, P.; Belforte, S.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Zanetti, A.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Lee, J.; Lee, S.; Lee, S. W.; Moon, C. S.; Oh, Y. D.; Sekmen, S.; Son, D. C.; Yang, Y. C.; Lee, A.; Kim, H.; Moon, D. H.; Oh, G.; Brochero Cifuentes, J. A.; Goh, J.; Kim, T. J.; Cho, S.; Choi, S.; Go, Y.; Gyun, D.; Ha, S.; Hong, B.; Jo, Y.; Kim, Y.; Lee, K.; Lee, K. S.; Lee, S.; Lim, J.; Park, S. K.; Roh, Y.; Almond, J.; Kim, J.; Kim, J. S.; Lee, H.; Lee, K.; Nam, K.; Oh, S. B.; Radburn-Smith, B. C.; Seo, S. h.; Yang, U. K.; Yoo, H. D.; Yu, G. B.; Choi, M.; Kim, H.; Kim, J. H.; Lee, J. S. H.; Park, I. C.; Choi, Y.; Hwang, C.; Lee, J.; Yu, I.; Dudenas, V.; Juodagalvis, A.; Vaitkus, J.; Ahmed, I.; Ibrahim, Z. A.; Md Ali, M. A. B.; Mohamad Idris, F.; Wan Abdullah, W. A. T.; Yusli, M. N.; Zolkapli, Z.; Reyes-Almanza, R.; Ramirez-Sanchez, G.; Duran-Osuna, M. C.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-De La Cruz, I.; Rabadan-Trejo, R. I.; Lopez-Fernandez, R.; Mejia Guisao, J.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Oropeza Barrera, C.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Uribe Estrada, C.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Saddique, A.; Shah, M. A.; Shoaib, M.; Waqas, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Szleper, M.; Zalewski, P.; Bunkowski, K.; Byszuk, A.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Pyskir, A.; Walczak, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Di Francesco, A.; Faccioli, P.; Galinhas, B.; Gallinaro, M.; Hollar, J.; Leonardo, N.; Lloret Iglesias, L.; Nemallapudi, M. V.; Seixas, J.; Strong, G.; Toldaiev, O.; Vadruccio, D.; Varela, J.; Afanasiev, S.; Bunin, P.; Gavrilenko, M.; Golutvin, I.; Gorbunov, I.; Kamenev, A.; Karjavin, V.; Lanev, A.; Malakhov, A.; Matveev, V.; Palichik, V.; Perelygin, V.; Shmatov, S.; Shulha, S.; Skatchkov, N.; Smirnov, V.; Voytishin, N.; Zarubin, A.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Karneyeu, A.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Spiridonov, A.; Stepennov, A.; Toms, M.; Vlasov, E.; Zhokin, A.; Aushev, T.; Bylinkin, A.; Chadeeva, M.; Parygin, P.; Philippov, D.; Polikarpov, S.; Popova, E.; Rusinov, V.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Terkulov, A.; Baskakov, A.; Belyaev, A.; Boos, E.; Bunichev, V.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Miagkov, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Blinov, V.; Skovpen, Y.; Shtol, D.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Elumakhov, D.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Petrov, V.; Ryutin, R.; Sobol, A.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Cirkovic, P.; Devetak, D.; Dordevic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Barrio Luna, M.; Cerrada, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Moran, D.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Álvarez Fernández, A.; de Trocóniz, J. F.; Missiroli, M.; Cuevas, J.; Erice, C.; Fernandez Menendez, J.; Gonzalez Caballero, I.; González Fernández, J. R.; Palencia Cortezon, E.; Sanchez Cruz, S.; Vischia, P.; Vizan Garcia, J. M.; Cabrillo, I. J.; Calderon, A.; Chazin Quero, B.; Curras, E.; Duarte Campderros, J.; Fernandez, M.; Garcia-Ferrero, J.; Gomez, G.; Lopez Virto, A.; Marco, J.; Martinez Rivero, C.; Martinez Ruiz del Arbol, P.; Matorras, F.; Piedra Gomez, J.; Rodrigo, T.; Ruiz-Jimeno, A.; Scodellaro, L.; Trevisani, N.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Baillon, P.; Ball, A. H.; Barney, D.; Bianco, M.; Bloch, P.; Bocci, A.; Botta, C.; Camporesi, T.; Castello, R.; Cepeda, M.; Cerminara, G.; Chapon, E.; Chen, Y.; d'Enterria, D.; Dabrowski, A.; Daponte, V.; David, A.; De Gruttola, M.; De Roeck, A.; Dobson, M.; Dorney, B.; du Pree, T.; Dünser, M.; Dupont, N.; Elliott-Peisert, A.; Everaerts, P.; Fallavollita, F.; Franzoni, G.; Fulcher, J.; Funk, W.; Gigi, D.; Gilbert, A.; Gill, K.; Glege, F.; Gulhan, D.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Karacheban, O.; Kieseler, J.; Kirschenmann, H.; Knünz, V.; Kornmayer, A.; Kortelainen, M. J.; Krammer, M.; Lange, C.; Lecoq, P.; Lourenço, C.; Lucchini, M. T.; Malgeri, L.; Mannelli, M.; Martelli, A.; Meijers, F.; Merlin, J. A.; Mersi, S.; Meschi, E.; Milenovic, P.; Moortgat, F.; Mulders, M.; Neugebauer, H.; Ngadiuba, J.; Orfanelli, S.; Orsini, L.; Pape, L.; Perez, E.; Peruzzi, M.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pierini, M.; Racz, A.; Reis, T.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Seidel, M.; Selvaggi, M.; Sharma, A.; Silva, P.; Sphicas, P.; Stakia, A.; Steggemann, J.; Stoye, M.; Tosi, M.; Treille, D.; Triossi, A.; Tsirou, A.; Veckalns, V.; Verweij, M.; Zeuner, W. D.; Bertl, W.; Caminada, L.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Rohe, T.; Wiederkehr, S. A.; Bäni, L.; Berger, P.; Bianchini, L.; Casal, B.; Dissertori, G.; Dittmar, M.; Donegà, M.; Grab, C.; Heidegger, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Klijnsma, T.; Lustermann, W.; Mangano, B.; Marionneau, M.; Meinhard, M. T.; Meister, D.; Micheli, F.; Musella, P.; Nessi-Tedaldi, F.; Pandolfi, F.; Pata, J.; Pauss, F.; Perrin, G.; Perrozzi, L.; Quittnat, M.; Reichmann, M.; Schönenberger, M.; Shchutska, L.; Tavolaro, V. R.; Theofilatos, K.; Vesterbacka Olsson, M. L.; Wallny, R.; Zhu, D. H.; Aarrestad, T. K.; Amsler, C.; Canelli, M. F.; De Cosa, A.; Del Burgo, R.; Donato, S.; Galloni, C.; Hreus, T.; Kilminster, B.; Pinna, D.; Rauco, G.; Robmann, P.; Salerno, D.; Seitz, C.; Takahashi, Y.; Zucchetta, A.; Candelise, V.; Doan, T. H.; Jain, Sh.; Khurana, R.; Kuo, C. M.; Lin, W.; Pozdnyakov, A.; Yu, S. S.; Kumar, Arun; Chang, P.; Chao, Y.; Chen, K. F.; Chen, P. H.; Fiori, F.; Hsiung, Y.; Liu, Y. F.; Lu, R.-S.; Paganis, E.; Psallidas, A.; Steen, A.; Tsai, J. f.; Asavapibhop, B.; Kovitanggoon, K.; Singh, G.; Srimanobhas, N.; Boran, F.; Cerci, S.; Damarseckin, S.; Demiroglu, Z. S.; Dozen, C.; Dumanoglu, I.; Girgis, S.; Gokbulut, G.; Guler, Y.; Hos, I.; Kangal, E. E.; Kara, O.; Kayis Topaksu, A.; Kiminsu, U.; Oglakci, M.; Onengut, G.; Ozdemir, K.; Sunar Cerci, D.; Tali, B.; Turkcapar, S.; Zorbakir, I. S.; Zorbilmez, C.; Bilin, B.; Karapinar, G.; Ocalan, K.; Yalvac, M.; Zeyrek, M.; Gülmez, E.; Kaya, M.; Kaya, O.; Tekten, S.; Yetkin, E. A.; Agaras, M. N.; Atay, S.; Cakir, A.; Cankocak, K.; Grynyov, B.; Levchuk, L.; Aggleton, R.; Ball, F.; Beck, L.; Brooke, J. J.; Burns, D.; Clement, E.; Cussans, D.; Davignon, O.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Smith, D.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Calligaris, L.; Cieri, D.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Auzinger, G.; Bainbridge, R.; Borg, J.; Breeze, S.; Buchmuller, O.; Bundock, A.; Casasso, S.; Citron, M.; Colling, D.; Corpe, L.; Dauncey, P.; Davies, G.; De Wit, A.; Della Negra, M.; Di Maria, R.; Elwood, A.; Haddad, Y.; Hall, G.; Iles, G.; James, T.; Lane, R.; Laner, C.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mastrolorenzo, L.; Matsushita, T.; Nash, J.; Nikitenko, A.; Palladino, V.; Pesaresi, M.; Raymond, D. M.; Richards, A.; Rose, A.; Scott, E.; Seez, C.; Shtipliyski, A.; Summers, S.; Tapper, A.; Uchida, K.; Vazquez Acosta, M.; Virdee, T.; Wardle, N.; Winterbottom, D.; Wright, J.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Borzou, A.; Call, K.; Dittmann, J.; Hatakeyama, K.; Liu, H.; Pastika, N.; Smith, C.; Bartek, R.; Dominguez, A.; Buccilli, A.; Cooper, S. I.; Henderson, C.; Rumerio, P.; West, C.; Arcaro, D.; Avetisyan, A.; Bose, T.; Gastler, D.; Rankin, D.; Richardson, C.; Rohlf, J.; Sulak, L.; Zou, D.; Benelli, G.; Cutts, D.; Garabedian, A.; Hakala, J.; Heintz, U.; Hogan, J. M.; Kwok, K. H. M.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Pazzini, J.; Piperov, S.; Sagir, S.; Syarif, R.; Yu, D.; Band, R.; Brainerd, C.; Burns, D.; Calderon De La Barca Sanchez, M.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Flores, C.; Funk, G.; Gardner, M.; Ko, W.; Lander, R.; Mclean, C.; Mulhearn, M.; Pellett, D.; Pilot, J.; Shalhout, S.; Shi, M.; Smith, J.; Stolp, D.; Tos, K.; Tripathi, M.; Wang, Z.; Bachtis, M.; Bravo, C.; Cousins, R.; Dasgupta, A.; Florent, A.; Hauser, J.; Ignatenko, M.; Mccoll, N.; Regnard, S.; Saltzberg, D.; Schnaible, C.; Valuev, V.; Bouvier, E.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Ghiasi Shirazi, S. M. A.; Hanson, G.; Heilman, J.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Olmedo Negrete, M.; Paneva, M. I.; Shrinivas, A.; Si, W.; Wang, L.; Wei, H.; Wimpenny, S.; Yates, B. R.; Branson, J. G.; Cittolin, S.; Derdzinski, M.; Gerosa, R.; Hashemi, B.; Holzner, A.; Klein, D.; Kole, G.; Krutelyov, V.; Letts, J.; Macneill, I.; Masciovecchio, M.; Olivito, D.; Padhi, S.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Vartak, A.; Wasserbaech, S.; Wood, J.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Amin, N.; Bhandari, R.; Bradmiller-Feld, J.; Campagnari, C.; Dishaw, A.; Dutta, V.; Franco Sevilla, M.; George, C.; Golf, F.; Gouskos, L.; Gran, J.; Heller, R.; Incandela, J.; Mullin, S. D.; Ovcharova, A.; Qu, H.; Richman, J.; Stuart, D.; Suarez, I.; Yoo, J.; Anderson, D.; Bendavid, J.; Bornheim, A.; Lawhorn, J. M.; Newman, H. B.; Nguyen, T.; Pena, C.; Spiropulu, M.; Vlimant, J. R.; Xie, S.; Zhang, Z.; Zhu, R. Y.; Andrews, M. B.; Ferguson, T.; Mudholkar, T.; Paulini, M.; Russ, J.; Sun, M.; Vogel, H.; Vorobiev, I.; Weinberg, M.; Cumalat, J. P.; Ford, W. T.; Jensen, F.; Johnson, A.; Krohn, M.; Leontsinis, S.; Mulholland, T.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chaves, J.; Chu, J.; Dittmer, S.; Mcdermott, K.; Mirman, N.; Patterson, J. R.; Rinkevicius, A.; Ryd, A.; Skinnari, L.; Soffi, L.; Tan, S. M.; Tao, Z.; Thom, J.; Tucker, J.; Wittich, P.; Zientek, M.; Abdullin, S.; Albrow, M.; Alyari, M.; Apollinari, G.; Apresyan, A.; Apyan, A.; Banerjee, S.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Canepa, A.; Cerati, G. B.; Cheung, H. W. K.; Chlebana, F.; Cremonesi, M.; Duarte, J.; Elvira, V. D.; Freeman, J.; Gecse, Z.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Harris, R. M.; Hasegawa, S.; Hirschauer, J.; Hu, Z.; Jayatilaka, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Lammel, S.; Lincoln, D.; Lipton, R.; Liu, M.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Magini, N.; Marraffino, J. M.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mrenna, S.; Nahn, S.; O'Dell, V.; Pedro, K.; Prokofyev, O.; Rakness, G.; Ristori, L.; Schneider, B.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Stoynev, S.; Strait, J.; Strobbe, N.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vernieri, C.; Verzocchi, M.; Vidal, R.; Wang, M.; Weber, H. A.; Whitbeck, A.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Brinkerhoff, A.; Carnes, A.; Carver, M.; Curry, D.; Field, R. D.; Furic, I. K.; Konigsberg, J.; Korytov, A.; Kotov, K.; Ma, P.; Matchev, K.; Mei, H.; Mitselmakher, G.; Rank, D.; Sperka, D.; Terentyev, N.; Thomas, L.; Wang, J.; Wang, S.; Yelton, J.; Joshi, Y. R.; Linn, S.; Markowitz, P.; Rodriguez, J. L.; Ackert, A.; Adams, T.; Askew, A.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Kolberg, T.; Martinez, G.; Perry, T.; Prosper, H.; Saha, A.; Santra, A.; Sharma, V.; Yohay, R.; Baarmand, M. M.; Bhopatkar, V.; Colafranceschi, S.; Hohlmann, M.; Noonan, D.; Roy, T.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Cavanaugh, R.; Chen, X.; Evdokimov, O.; Gerber, C. E.; Hangal, D. A.; Hofman, D. J.; Jung, K.; Kamin, J.; Sandoval Gonzalez, I. D.; Tonjes, M. B.; Trauger, H.; Varelas, N.; Wang, H.; Wu, Z.; Zhang, J.; Bilki, B.; Clarida, W.; Dilsiz, K.; Durgut, S.; Gandrajula, R. P.; Haytmyradov, M.; Khristenko, V.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Snyder, C.; Tiras, E.; Wetzel, J.; Yi, K.; Blumenfeld, B.; Cocoros, A.; Eminizer, N.; Fehling, D.; Feng, L.; Gritsan, A. V.; Maksimovic, P.; Roskes, J.; Sarica, U.; Swartz, M.; Xiao, M.; You, C.; Al-bataineh, A.; Baringer, P.; Bean, A.; Boren, S.; Bowen, J.; Castle, J.; Khalil, S.; Kropivnitskaya, A.; Majumder, D.; Mcbrayer, W.; Murray, M.; Royon, C.; Sanders, S.; Schmitz, E.; Tapia Takaki, J. D.; Wang, Q.; Ivanov, A.; Kaadze, K.; Maravin, Y.; Mohammadi, A.; Saini, L. K.; Skhirtladze, N.; Toda, S.; Rebassoo, F.; Wright, D.; Anelli, C.; Baden, A.; Baron, O.; Belloni, A.; Calvert, B.; Eno, S. C.; Ferraioli, C.; Hadley, N. J.; Jabeen, S.; Jeng, G. Y.; Kellogg, R. G.; Kunkle, J.; Mignerey, A. C.; Ricci-Tam, F.; Shin, Y. H.; Skuja, A.; Tonwar, S. C.; Abercrombie, D.; Allen, B.; Azzolini, V.; Barbieri, R.; Baty, A.; Bi, R.; Brandt, S.; Busza, W.; Cali, I. A.; D'Alfonso, M.; Demiragli, Z.; Gomez Ceballos, G.; Goncharov, M.; Hsu, D.; Iiyama, Y.; Innocenti, G. M.; Klute, M.; Kovalskyi, D.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Maier, B.; Marini, A. C.; Mcginn, C.; Mironov, C.; Narayanan, S.; Niu, X.; Paus, C.; Roland, C.; Roland, G.; Salfeld-Nebgen, J.; Stephans, G. S. F.; Tatar, K.; Velicanu, D.; Wang, J.; Wang, T. W.; Wyslouch, B.; Benvenuti, A. C.; Chatterjee, R. M.; Evans, A.; Hansen, P.; Kalafut, S.; Kubota, Y.; Lesko, Z.; Mans, J.; Nourbakhsh, S.; Ruckstuhl, N.; Rusack, R.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Claes, D. R.; Fangmeier, C.; Gonzalez Suarez, R.; Kamalieddin, R.; Kravchenko, I.; Monroy, J.; Siado, J. E.; Snow, G. R.; Stieger, B.; Dolen, J.; Godshalk, A.; Harrington, C.; Iashvili, I.; Nguyen, D.; Parker, A.; Rappoccio, S.; Roozbahani, B.; Alverson, G.; Barberis, E.; Hortiangtham, A.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Teixeira De Lima, R.; Trocino, D.; Wood, D.; Bhattacharya, S.; Charaf, O.; Hahn, K. A.; Mucia, N.; Odell, N.; Pollack, B.; Schmitt, M. H.; Sung, K.; Trovato, M.; Velasco, M.; Dev, N.; Hildreth, M.; Hurtado Anampa, K.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Loukas, N.; Marinelli, N.; Meng, F.; Mueller, C.; Musienko, Y.; Planer, M.; Reinsvold, A.; Ruchti, R.; Smith, G.; Taroni, S.; Wayne, M.; Wolf, M.; Woodard, A.; Alimena, J.; Antonelli, L.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Francis, B.; Hart, A.; Hill, C.; Ji, W.; Liu, B.; Luo, W.; Puigh, D.; Winer, B. L.; Wulsin, H. W.; Cooperstein, S.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Higginbotham, S.; Lange, D.; Luo, J.; Marlow, D.; Mei, K.; Ojalvo, I.; Olsen, J.; Palmer, C.; Piroué, P.; Stickland, D.; Tully, C.; Malik, S.; Norberg, S.; Barker, A.; Barnes, V. E.; Das, S.; Folgueras, S.; Gutay, L.; Jha, M. K.; Jones, M.; Jung, A. W.; Khatiwada, A.; Miller, D. H.; Neumeister, N.; Peng, C. C.; Schulte, J. F.; Sun, J.; Wang, F.; Xie, W.; Cheng, T.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Chen, Z.; Ecklund, K. M.; Geurts, F. J. M.; Guilbaud, M.; Li, W.; Michlin, B.; Northup, M.; Padley, B. P.; Roberts, J.; Rorie, J.; Tu, Z.; Zabel, J.; Bodek, A.; de Barbaro, P.; Demina, R.; Duh, Y. t.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Han, J.; Hindrichs, O.; Khukhunaishvili, A.; Lo, K. H.; Tan, P.; Verzetti, M.; Ciesielski, R.; Goulianos, K.; Mesropian, C.; Agapitos, A.; Chou, J. P.; Gershtein, Y.; Gómez Espinosa, T. A.; Halkiadakis, E.; Heindl, M.; Hughes, E.; Kaplan, S.; Kunnawalkam Elayavalli, R.; Kyriacou, S.; Lath, A.; Montalvo, R.; Nash, K.; Osherson, M.; Saka, H.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Delannoy, A. G.; Foerster, M.; Heideman, J.; Riley, G.; Rose, K.; Spanier, S.; Thapa, K.; Bouhali, O.; Castaneda Hernandez, A.; Celik, A.; Dalchenko, M.; De Mattia, M.; Delgado, A.; Dildick, S.; Eusebi, R.; Gilmore, J.; Huang, T.; Kamon, T.; Mueller, R.; Pakhotin, Y.; Patel, R.; Perloff, A.; Perniè, L.; Rathjens, D.; Safonov, A.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Damgov, J.; De Guio, F.; Dudero, P. R.; Faulkner, J.; Gurpinar, E.; Kunori, S.; Lamichhane, K.; Lee, S. W.; Libeiro, T.; Peltola, T.; Undleeb, S.; Volobouev, I.; Wang, Z.; Greene, S.; Gurrola, A.; Janjam, R.; Johns, W.; Maguire, C.; Melo, A.; Ni, H.; Padeken, K.; Sheldon, P.; Tuo, S.; Velkovska, J.; Xu, Q.; Arenton, M. W.; Barria, P.; Cox, B.; Hirosky, R.; Joyce, M.; Ledovskoy, A.; Li, H.; Neu, C.; Sinthuprasith, T.; Wang, Y.; Wolfe, E.; Xia, F.; Harr, R.; Karchin, P. E.; Sturdy, J.; Zaleski, S.; Brodski, M.; Buchanan, J.; Caillol, C.; Dasu, S.; Dodd, L.; Duric, S.; Gomber, B.; Grothe, M.; Herndon, M.; Hervé, A.; Hussain, U.; Klabbers, P.; Lanaro, A.; Levine, A.; Long, K.; Loveless, R.; Pierro, G. A.; Polese, G.; Ruggles, T.; Savin, A.; Smith, N.; Smith, W. H.; Taylor, D.; Woods, N.; CMS Collaboration
2018-04-01
A measurement of the H → ττ signal strength is performed using events recorded in proton-proton collisions by the CMS experiment at the LHC in 2016 at a center-of-mass energy of 13TeV. The data set corresponds to an integrated luminosity of 35.9fb-1. The H → ττ signal is established with a significance of 4.9 standard deviations, to be compared to an expected significance of 4.7 standard deviations. The best fit of the product of the observed H → ττ signal production cross section and branching fraction is 1.09-0.26+0.27 times the standard model expectation. The combination with the corresponding measurement performed with data collected by the CMS experiment at center-of-mass energies of 7 and 8TeV leads to an observed significance of 5.9 standard deviations, equal to the expected significance. This is the first observation of Higgs boson decays to τ leptons by a single experiment.
Passive PE Sampling in Support of In Situ Remediation of Contaminated Sediments
2015-08-01
control RPD relative percent difference RSD relative standard deviation SERDP Strategic Environmental Research and Development Program SOPs...sediments from 2 stations, each at 4 PCB spike levels, for four individual congeners was 22 ± 6 % relative standard deviation ( RSD ). Also, comparison of... RSD (Table 3). However, larger congeners (e.g., congeners #153 and 180) whose approach to equilibrium is less certain, based on small fractions of
NASA Astrophysics Data System (ADS)
Mohammadian, Shahabeddin K.; Zhang, Yuwen
2015-01-01
Three dimensional transient thermal analysis of an air-cooled module that contains prismatic Li-ion cells next to a special kind of aluminum pin fin heat sink whose heights of pin fins increase linearly through the width of the channel in air flow direction was studied for thermal management of Lithium-ion battery pack. The effects of pin fins arrangements, discharge rates, inlet air flow velocities, and inlet air temperatures on the battery were investigated. The results showed that despite of heat sinks with uniform pin fin heights that increase the standard deviation of the temperature field, using this kind of pin fin heat sink compare to the heat sink without pin fins not only decreases the bulk temperature inside the battery, but also decreases the standard deviation of the temperature field inside the battery as well. Increasing the inlet air temperature leads to decreasing the standard deviation of the temperature field while increases the maximum temperature of the battery. Furthermore, increasing the inlet air velocity first increases the standard deviation of the temperature field till reaches to the maximum point, and after that decreases. Also, increasing the inlet air velocity leads to decrease in the maximum temperature of the battery.
Colavecchia, A Carmine; Cohen, David A; Harris, Jesse E; Thomas, Jeena M; Lindberg, Scott; Leveque, Christopher; Salazar, Eric
2017-12-01
Major bleeding in orthotopic liver transplantation is associated with significant morbidity and mortality. Limited literature exists regarding comparative effectiveness of prothrombin complex concentrate and fibrinogen concentrate during orthotopic liver transplantation on blood product utilization. This retrospective, single-institution study evaluated the impact of prothrombin complex concentrate and fibrinogen concentrate on blood product utilization during orthotopic liver transplantation from December 2013 to April 2016. This study included patients age 18 years or older and excluded patients who received simultaneous heart or lung transplantation or did not meet documentation criteria. A propensity score matching technique was used to match patients who were exposed to prothrombin complex concentrate with unexposed patients, at a 2 to 1 ratio, to control for selection bias. During this study, 212 patients received orthotopic liver transplantation with 39 prothrombin complex concentrate exposures. The matched study population included 39 patients who were exposed to prothrombin complex concentrate and 78 unexposed patients. Overall, 84.6% of patients who were exposed to prothrombin complex concentrate also received concomitant fibrinogen concentrate, whereas only 2% of patients in the control group received fibrinogen concentrate. After propensity score matching, no other factors that were included in the model differed significantly or had a standardized mean difference of 0.11 or greater. There was no statistical difference in the utilization of red blood cells or fresh frozen plasma for the exposed group versus the unexposed group after matching (mean ± standard deviation: red blood cell units, 12.4 ± 8.0 units vs. 9.7 ± 5.6 units [p = 0.058]; fresh-frozen plasma units, 10.0 ± 6.3 vs. 12.7 ± 9.7 units [p = 0.119], respectively). The intraoperative use of prothrombin complex concentrate and fibrinogen concentrate during orthotopic liver transplantation did not reduce intraoperative blood product requirements at a single institution. © 2017 AABB.
Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun
2007-10-15
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.
[Determination of trace gallium by graphite furnace atomic absorption spectrometry in urine].
Zhou, L Z; Fu, S; Gao, S Q; He, G W
2016-06-20
To establish a method for determination trace gallium in urine by graphite furnace atomic absorption spectrometry (GFAAS). The ammonium dihydrogen phosphate was matrix modifier. The temperature effect about pyrolysis (Tpyr) and atomization temperature were optimized for determination of trace gallium. The method of technical standard about within-run, between-run and recoveries of standard were optimized. The method showed a linear relationship within the range of 0.20~80.00 μg/L (r=0.998). The within-run and between-run relative standard deviations (RSD) of repetitive measurement at 5.0, 10.0, 20.0 μg/L concentration levels were 2.1%~5.5% and 2.3%~3.0%. The detection limit was 0.06 μg/L. The recoveries of gallium were 98.2%~101.1%. This method is simple, low detection limit, accurate, reliable and reproducible. It has been applied for determination of trace gallium in urine samples those who need occupation health examination or poisoning diagnosis.
Niopas, Ioannis; Daftsios, Athanasios C
2002-05-15
Glibenclamide is a potent second generation oral sulfonylurea antidiabetic agent widely used for the treatment of type II diabetes melitus. A rapid, sensitive, precise, accurate and specific HPLC assay for the determination of glibenclamide in human plasma was developed and validated. After addition of flufenamic acid as internal standard, the analytes were isolated from human plasma by liquid-liquid extraction. The method was linear in the 10-400 ng/ml concentration range (r > 0.999). Recovery for glibenclamide was greater than 91.5% and for internal standard was 93.5%. Within-day and between-day precision, expressed as the relative standard deviation (RSD%), ranged from 1.4 to 5.9% and 5.8 to 6.6%, respectively. Assay accuracy was better than 93.4%. The assay was used to estimate the pharmacokinetics of glibenclamide after oral administration of a 5 mg tablet of glibenclamide to 18 healthy volunteers.
Verification of spectrophotometric method for nitrate analysis in water samples
NASA Astrophysics Data System (ADS)
Kurniawati, Puji; Gusrianti, Reny; Dwisiwi, Bledug Bernanti; Purbaningtias, Tri Esti; Wiyantoko, Bayu
2017-12-01
The aim of this research was to verify the spectrophotometric method to analyze nitrate in water samples using APHA 2012 Section 4500 NO3-B method. The verification parameters used were: linearity, method detection limit, level of quantitation, level of linearity, accuracy and precision. Linearity was obtained by using 0 to 50 mg/L nitrate standard solution and the correlation coefficient of standard calibration linear regression equation was 0.9981. The method detection limit (MDL) was defined as 0,1294 mg/L and limit of quantitation (LOQ) was 0,4117 mg/L. The result of a level of linearity (LOL) was 50 mg/L and nitrate concentration 10 to 50 mg/L was linear with a level of confidence was 99%. The accuracy was determined through recovery value was 109.1907%. The precision value was observed using % relative standard deviation (%RSD) from repeatability and its result was 1.0886%. The tested performance criteria showed that the methodology was verified under the laboratory conditions.
The linear sizes tolerances and fits system modernization
NASA Astrophysics Data System (ADS)
Glukhov, V. I.; Grinevich, V. A.; Shalay, V. V.
2018-04-01
The study is carried out on the urgent topic for technical products quality providing in the tolerancing process of the component parts. The aim of the paper is to develop alternatives for improving the system linear sizes tolerances and dimensional fits in the international standard ISO 286-1. The tasks of the work are, firstly, to classify as linear sizes the elements additionally linear coordinating sizes that determine the detail elements location and, secondly, to justify the basic deviation of the tolerance interval for the element's linear size. The geometrical modeling method of real details elements, the analytical and experimental methods are used in the research. It is shown that the linear coordinates are the dimensional basis of the elements linear sizes. To standardize the accuracy of linear coordinating sizes in all accuracy classes, it is sufficient to select in the standardized tolerance system only one tolerance interval with symmetrical deviations: Js for internal dimensional elements (holes) and js for external elements (shafts). The main deviation of this coordinating tolerance is the average zero deviation, which coincides with the nominal value of the coordinating size. Other intervals of the tolerance system are remained for normalizing the accuracy of the elements linear sizes with a fundamental change in the basic deviation of all tolerance intervals is the maximum deviation corresponding to the limit of the element material: EI is the lower tolerance for the of the internal elements (holes) sizes and es is the upper tolerance deviation for the outer elements (shafts) sizes. It is the sizes of the material maximum that are involved in the of the dimensional elements mating of the shafts and holes and determine the fits type.
Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Background Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. Materials and Methods We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Results Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was −0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >−0.33 (odds ratio, 5.88; 95% confidence interval, 3.04–12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79–6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85–92.13) were independent risk of intraoperative massive hemorrhage. Conclusion In patients with placenta previa, a birth weight >−0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa. PMID:27902772
Soyama, Hiroaki; Miyamoto, Morikazu; Ishibashi, Hiroki; Takano, Masashi; Sasa, Hidenori; Furuya, Kenichi
2016-01-01
Placenta previa, one of the most severe obstetric complications, carries an increased risk of intraoperative massive hemorrhage. Several risk factors for intraoperative hemorrhage have been identified to date. However, the correlation between birth weight and intraoperative hemorrhage has not been investigated. Here we estimate the correlation between birth weight and the occurrence of intraoperative massive hemorrhage in placenta previa. We included all 256 singleton pregnancies delivered via cesarean section at our hospital because of placenta previa between 2003 and 2015. We calculated not only measured birth weights but also standard deviation values according to the Japanese standard growth curve to adjust for differences in gestational age. We assessed the correlation between birth weight and the occurrence of intraoperative massive hemorrhage (>1500 mL blood loss). Receiver operating characteristic curves were constructed to determine the cutoff value of intraoperative massive hemorrhage. Of 256 pregnant women with placenta previa, 96 (38%) developed intraoperative massive hemorrhage. Receiver-operating characteristic curves revealed that the area under the curve of the combination variables between the standard deviation of birth weight and intraoperative massive hemorrhage was 0.71. The cutoff value with a sensitivity of 81.3% and specificity of 55.6% was -0.33 standard deviation. The multivariate analysis revealed that a standard deviation of >-0.33 (odds ratio, 5.88; 95% confidence interval, 3.04-12.00), need for hemostatic procedures (odds ratio, 3.31; 95% confidence interval, 1.79-6.25), and placental adhesion (odds ratio, 12.68; 95% confidence interval, 2.85-92.13) were independent risk of intraoperative massive hemorrhage. In patients with placenta previa, a birth weight >-0.33 standard deviation was a significant risk indicator of massive hemorrhage during cesarean section. Based on this result, further studies are required to investigate whether fetal weight estimated by ultrasonography can predict hemorrhage during cesarean section in patients with placental previa.
El Beltagi, Tarek A; Bowd, Christopher; Boden, Catherine; Amini, Payam; Sample, Pamela A; Zangwill, Linda M; Weinreb, Robert N
2003-11-01
To determine the relationship between areas of glaucomatous retinal nerve fiber layer thinning identified by optical coherence tomography and areas of decreased visual field sensitivity identified by standard automated perimetry in glaucomatous eyes. Retrospective observational case series. Forty-three patients with glaucomatous optic neuropathy identified by optic disc stereo photographs and standard automated perimetry mean deviations >-8 dB were included. Participants were imaged with optical coherence tomography within 6 months of reliable standard automated perimetry testing. The location and number of optical coherence tomography clock hour retinal nerve fiber layer thickness measures outside normal limits were compared with the location and number of standard automated perimetry visual field zones outside normal limits. Further, the relationship between the deviation from normal optical coherence tomography-measured retinal nerve fiber layer thickness at each clock hour and the average pattern deviation in each visual field zone was examined by using linear regression (R(2)). The retinal nerve fiber layer areas most frequently outside normal limits were the inferior and inferior temporal regions. The least sensitive visual field zones were in the superior hemifield. Linear regression results (R(2)) showed that deviation from the normal retinal nerve fiber layer thickness at optical coherence tomography clock hour positions 6 o'clock, 7 o'clock, and 8 o'clock (inferior and inferior temporal) was best correlated with standard automated perimetry pattern deviation in visual field zones corresponding to the superior arcuate and nasal step regions (R(2) range, 0.34-0.57). These associations were much stronger than those between clock hour position 6 o'clock and the visual field zone corresponding to the inferior nasal step region (R(2) = 0.01). Localized retinal nerve fiber layer thinning, measured by optical coherence tomography, is topographically related to decreased localized standard automated perimetry sensitivity in glaucoma patients.
Automating linear accelerator quality assurance.
Eckhause, Tobias; Al-Hallaq, Hania; Ritter, Timothy; DeMarco, John; Farrey, Karl; Pawlicki, Todd; Kim, Gwe-Ya; Popple, Richard; Sharma, Vijeshwar; Perez, Mario; Park, SungYong; Booth, Jeremy T; Thorwarth, Ryan; Moran, Jean M
2015-10-01
The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.
Zoliana, B; Rohmingliana, P C; Sahoo, B K; Mishra, R; Mayya, Y S
2016-10-01
Indoor radon/thoron concentration has been measured in Aizawl district, Mizoram, India, which has the highest lung cancer incidence rates among males and females in India. Simultaneously, radon flux emanated from the surrounding soil of the dwellings was observed in selected places. The annual average value of concentration of radon(thoron) of Aizawl district is 48.8(22.65) Bq m -3 with a geometric standard deviation of 1.25(1.58). Measured radon flux from the soil has an average value of 22.6 mBq m -2 s -1 These results were found to be much below the harmful effect or action level as indicated by the World Health Organisation. On the other hand, food habit and high-level consumption of tobacco and its products in the district have been found to increase the risk of lung cancer incidence in the district. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Andersen, Claus E; Raaschou-Nielsen, Ole; Andersen, Helle Primdal; Lind, Morten; Gravesen, Peter; Thomsen, Birthe L; Ulbak, Kaare
2007-01-01
A linear regression model has been developed for the prediction of indoor (222)Rn in Danish houses. The model provides proxy radon concentrations for about 21,000 houses in a Danish case-control study on the possible association between residential radon and childhood cancer (primarily leukaemia). The model was calibrated against radon measurements in 3116 houses. An independent dataset with 788 house measurements was used for model performance assessment. The model includes nine explanatory variables, of which the most important ones are house type and geology. All explanatory variables are available from central databases. The model was fitted to log-transformed radon concentrations and it has an R(2) of 40%. The uncertainty associated with individual predictions of (untransformed) radon concentrations is about a factor of 2.0 (one standard deviation). The comparison with the independent test data shows that the model makes sound predictions and that errors of radon predictions are only weakly correlated with the estimates themselves (R(2) = 10%).
Simple Colorimetric Sensor for Trinitrotoluene Testing
NASA Astrophysics Data System (ADS)
Samanman, S.; Masoh, N.; Salah, Y.; Srisawat, S.; Wattanayon, R.; Wangsirikul, P.; Phumivanichakit, K.
2017-02-01
A simple operating colorimetric sensor for trinitrotoluene (TNT) determination using a commercial scanner as a captured image was designed. The sensor is based on the chemical reaction between TNT and sodium hydroxide reagent to produce the color change within 96 well plates, which observed finally, recorded using a commercial scanner. The intensity of the color change increased with increase in TNT concentration and could easily quantify the concentration of TNT by digital image analysis using the Image J free software. Under optimum conditions, the sensor provided a linear dynamic range between 0.20 and 1.00 mg mL-1(r = 0.9921) with a limit of detection of 0.10± 0.01 mg mL-1. The relative standard deviation for eight experiments for the sensitivity was 3.8%. When applied for the analysis of TNT in two soil extract samples, the concentrations were found to be non-detectable to 0.26±0.04 mg mL-1. The obtained recovery values (93-95%) were acceptable for soil samples tested.
Geogenic and anthropogenic impacts on indoor radon in the Techa River region.
Yarmoshenko, I; Malinovsky, G; Vasilyev, A; Onischenko, A; Seleznev, A
2016-11-15
Indoor radon concentration was studied in the 14 settlements located near the Techa River, which was contaminated by radioactive wastes in 1950-s. Results of the radon survey were used for analysis of the relationship between the indoor radon and main geologic factors (Pre-Jurassic formations, Quaternary sediments and faults), local geogenic radon potential and anthropogenic factors. Main influencing factors explain 58% of the standard deviation of indoor radon concentration. Association of the air exchange influence over radon concentration with underlying geological media was related to different contributions of geogenic advective and diffusive radon entries. The properties of geological formation to transfer radon gas in interaction with the house can be considered within the radon geogenic potential concept. The study of the radon exposure of the Techa River population can be used to estimate the contribution of natural radon to the overall radiation exposure of the local population during the period of radioactive waste discharges. Copyright © 2016 Elsevier B.V. All rights reserved.
May, Thomas W.; Walther, Michael J.
2013-01-01
This report presents results for the summer 2012 sam-pling of muscle plugs from common carp (Cyprinus carpio), bonytail chub (Gila elegans), Colorado pikeminnow (Ptycho-cheilus lucius), and razorback suckers (Xyrauchen texanus) inhabiting critical habitat in the Gunnison River in western Colorado. Total selenium in fish muscle plugs was determinedby instrumental neutron activation analysis. Total selenium concentrations (range and mean ± standard deviation) in micrograms per gram dry weight were 6.0 to 10.7, 8.8 ± 1.3 for common carp; 2.9 to 8.7, 5.6 ± 2.4 for Colorado pikemin-now; and 1.4 to 7.3, 3.4 ± 2.7 for razorback sucker. The selenium concentration for one bonytail chub sample was 0.8 micrograms per gram dry weight. Selenium concentrations in muscle plugs from 1 Colorado pikeminnow and 12 common carp exceeded the 8 micrograms per gram dry weight toxicity guideline for selenium in fish muscle tissue.
Determination of uranium in natural waters
Barker, Franklin Butt; Johnson, J.O.; Edwards, K.W.; Robinson, B.P.
1965-01-01
A method is described for the determination of very low concentrations of uranium in water. The method is based on the fluorescence of uranium in a pad prepared by fusion of the dried solids from the water sample with a flux of 10 percent NaF 45.5 percent Na2CO3 , and 45.5 percent K2CO3 . This flux permits use of a low fusion temperature and yields pads which are easily removed from the platinum fusion dishes for fluorescence measurements. Uranium concentrations of less than 1 microgram per liter can be determined on a sample of 10 milliliters, or less. The sensitivity and accuracy of the method are dependent primarily on the purity of reagents used, the stability and linearity of the fluorimeter, and the concentration of quenching elements in the water residue. A purification step is recommended when the fluorescence is quenched by more than 30 percent. Equations are given for the calculation of standard deviations of analyses by this method. Graphs of error functions and representative data are also included.
Hexaacetato calix(6)arene as the novel extractant for palladium.
Mathew, V J; Khopkar, S M
1997-10-01
A novel method is proposed for the solvent extraction of palladium. A superamolecular compound, hexaacetato calix(6)arene in low concentration in toluene quantitatively extracts microgram concentration of palladium at pH 7.5. It can be stripped from the organic phase with 2 M nitric acid and determined spectrophotometrically as its stannous chloride complex at 635 nm. The probable composition of the extracted species is Pd(HR)(2)Cl. As low as 1x10(-3) M of extractant is adequate for quantitative extraction. Toluene was the best diluent. With nitric and perchloric acid (1.5-3 M) the stripping was complete. Palladium was separated in large ratios from alkali and alkaline earths (1:50). The main group elements were tolerated in higher ratios (1:25), but ions like zinc, cadmium, iron, nickel, platinium, thorium, vanadium and molydenum were tolerated at low concentrations (1:1). The ions showing strong interference were copper, chromium. The relative standard deviation is +/-1.1%.
Qiu, Zhong-Feng; Xi, Hong-Yan; He, Yi-Jun; Chen, Jay-Chung; Jian, Wei-Jun
2006-08-01
For the purpose of detecting and forecasting research of red tides to reduce the loss, a semi-analytic algorithm to retrieve chlorophyll-a concentrations was established in the area where red tides often brought out, according to the data collected during the red tides cruise in the East China Sea in April 2002. In the algorithm, empirical equations were made based on the coefficients from the in-situ data, including the optical properties of the research area. The in-situ data were used to validate the algorithm. The discrepancy of chlorophyll-a absorption coefficients and concentrations are mainly located in the region of 30%. The root mean deviation of the chlorophyll-a concentrations between the observed and the calculated is 0.24, the maximum relative deviation 40.93%, the mean relative deviation 18.83% and the correlation coefficient 0.83. The results show that the precision of the algorithm is high and the algorithm is fit for the research area.
Ishizaki, M
1978-03-01
A method for determination of selenium in biological materials by flameless atomic-absorption spectrometry using a carbon-tube atomizer is described. The sample is burned by an oxygen-flask combustion procedure, the resulting solution is treated with a cation-exchange resin to eliminate interfering cations, the selenium is extracted with dithizone in carbon tetrachloride and the resulting selenium dithizonate is combined with nickel nitrate in the carbon tube to enhance the sensitivity for selenium and avoid volatilization losses. The method measures selenium concentrations as low as 0.01 mug/g with a relative standard deviation of 8%.
Determination of trace arsenic on hanging copper amalgam drop electrode.
Piech, Robert; Baś, Bogusław; Niewiara, Ewa; Kubiak, Władysław W
2007-04-30
Hanging copper amalgam drop electrode has been applied for trace determination of arsenic by cathodic stripping analysis. Detection limit for As(III) as low as 0.33nM (0.02mug/L) at deposition time (240s) could be obtained. For seven successive determinations of As(III) at concentration of 5nM relative standard deviation was 2.5% (n=7). Interferences from selected metals and surfactant substances were examined. Absence of copper ions in sample solution causes easier optimization and makes method less vulnerable on contamination. The developed method was validated by analysis of certified reference materials (CRMs) and applied to arsenic determinations in natural water samples.
NASA Astrophysics Data System (ADS)
Masrournia, Mahboube; Montazarolmahdi, Maliheh; Sani, Faramarz Aliasghari
2017-07-01
Determination of dextrose in peritoneal dialysis with a method based on silver nanoparticles (AgNPs) formation was investigated. In a green chemistry method, silver nanoparticles (AgNPs) were synthesized in the natural polymeric matrix of gelatin. The nanoparticles were characterized with UV-Vis spectroscopy and transmission electron microscopy (TEM). Absorbance signal of AgNPs could be applied to determine the various concentrations of dextrose solutions. Drop wise and ultrasonic methods were used and compared with each other. The dynamic range of methods with limit of detection and relative standard deviations were obtained. Results for real sample (peritoneal dialysis) were satisfied.
Spectroscopic metrology for isotope composition measurements and transfer standards
NASA Astrophysics Data System (ADS)
Anyangwe Nwaboh, Javis; Balslev-Harder, David; Kääriäinen, Teemu; Richmond, Craig; Manninen, Albert; Mohn, Joachim; Kiseleva, Maria; Petersen, Jan C.; Werhahn, Olav; Ebert, Volker
2017-04-01
The World Meteorological Organization (WMO) has identified greenhouse gases such as CO2, CH4 and N2O as critical for global climate monitoring. Other molecules such as CO that has an indirect effect of enhancing global warming are also monitored. WMO has stated compatibility goals for atmospheric concentration and isotope ratio measurements of these gases, e.g. 0.1 ppm for CO2 concentration measurements in the northern hemisphere and 0.01 ‰ for δ13C-CO2. For measurements of the concentration of greenhouse gases, gas analysers are typically calibrated with static gas standards e.g. traceable to the WMO scale or to the International System of Units (SI) through a national metrology institute. However, concentrations of target components, e.g. CO, in static gas standards have been observed to drift, and typically the gas matrix as well as the isotopic composition of the target component does not always reflect field gas composition, leading to deviations of the analyser response, even after calibration. The deviations are dependent on the measurement technique. To address this issue, part of the HIGHGAS (Metrology for high-impact greenhouse gases) project [1] focused on the development of optical transfer standards (OTSs) for greenhouse gases, e.g. CO2 and CO, potentially complementing gas standards. Isotope ratio mass spectrometry (IRMS) [2] is currently used to provide state-of-the-art high precision (in the 0.01 ‰ range) measurements for the isotopic composition of greenhouse gases. However, there is a need for field-deployable techniques such as optical isotope ratio spectroscopy (OIRS) that can be combined with metrological measurement methods. Within the HIGHGAS project, OIRS methods and procedures based on e.g. cavity enhanced spectroscopy (CES) and tunable diode laser absorption spectroscopy (TDLAS), matched to metrological principles have been established for the measurement of 13C/12C and 18O/16O ratios in CO2, 15N/14N ratios in N2O, and 13C/12C and 2H/1H ratios in CH4. Here, based on HIGHGAS project results, we present OTSs for atmospheric CO2 and CO measurements. The results delivered by the OTSs are in excellent agreement with gravimetric values of metrological "primary" static gas standards. The repeatabilities of the OTS results are matching the compatibility goals stated by WMO for atmospheric CO2 and CO measurements. In addition, we present OIRS measurement methods and procedures to demonstrate their applicability and validation. The requirements on, e.g. absorption line data quality and temperature sensitivity of isotope ratio, are discussed. Uncertainty budgets are presented and the traceability of the results is addressed. The current limitations in our measurements are discussed and steps taken to address these limitations are presented. Acknowledgement Parts of this work have been carried out within the European Metrology Research Programme (EMRP) ENV52 project-HIGHGAS. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union. References [1] EMRP project ENV52-HIGHGAS, available at: http://www.euramet.org/ [2] Prosenjit Ghosh, Willi A. Brand, International Journal of Mass Spectrometry 228, 1-33 (2003).
Heydari, Rouhollah; Hosseini, Mohammad; Zarabi, Sanaz
2015-01-01
In this paper, a simple and cost effective method was developed for extraction and pre-concentration of carmine in food samples by using cloud point extraction (CPE) prior to its spectrophotometric determination. Carmine was extracted from aqueous solution using Triton X-100 as extracting solvent. The effects of main parameters such as solution pH, surfactant and salt concentrations, incubation time and temperature were investigated and optimized. Calibration graph was linear in the range of 0.04-5.0 μg mL(-1) of carmine in the initial solution with regression coefficient of 0.9995. The limit of detection (LOD) and limit of quantification were 0.012 and 0.04 μg mL(-1), respectively. Relative standard deviation (RSD) at low concentration level (0.05 μg mL(-1)) of carmine was 4.8% (n=7). Recovery values in different concentration levels were in the range of 93.7-105.8%. The obtained results demonstrate the proposed method can be applied satisfactory to determine the carmine in food samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Hernández, F; Hernández-Armas, J; Catalán, A; Fernández-Aldecoa, J C; Landeras, M I
2004-01-01
A total of 26 different food types and 12 elaborated diets were analysed by low-level gamma spectrometry to measure their content of 238U(234Th), 228Ra(228Ac), 226Ra(214Pb), 210Pb, 137Cs and 40K. The concentrations of these radionuclides measured in some imported foodstuffs were compared with those measured in some locally produced ones. Moreover, the concentrations found in the analysed foodstuffs and composite diets were compared with the data available in literature from other locations, such as Egypt, Brazil, Poland and Hong Kong. 40K contributed highest to the daily dose produced by the intake of comestibles. The largest 40K concentrations were measured in the chickpeas and beans with 380 +/- 30 and 380 +/- 20 Bq kg(-1) fresh weights, respectively. The artificial radionuclide 137Cs was measured only above detection limits in the potatoes and sweet potatoes. A mean annual effective dose of 362 microSv with a standard deviation of 110 microSv was calculated from the composite diets.
In vivo dosimetry for external photon treatments of head and neck cancers by diodes and TLDS.
Tung, C J; Wang, H C; Lo, S H; Wu, J M; Wang, C J
2004-01-01
In vivo dosimetry was implemented for treatments of head and neck cancers in the large fields. Diode and thermoluminescence dosemeter (TLD) measurements were carried out for the linear accelerators of 6 MV photon beams. ESTRO in vivo dosimetry protocols were followed in the determination of midline doses from measurements of entrance and exit doses. Of the fields monitored by diodes, the maximum absolute deviation of measured midline doses from planned target doses was 8%, with the mean value and the standard deviation of -1.0 and 2.7%. If planned target doses were calculated using radiological water equivalent thicknesses rather than patient geometric thicknesses, the maximum absolute deviation dropped to 4%, with the mean and the standard deviation of 0.7 and 1.8%. For in vivo dosimetry monitored by TLDs, the shift in mean dose remained small but the statistical precision became poor.
A visual tristimulus projection colorimeter.
Valberg, A
1971-01-01
Based on the optical principle of a slide projector, a visual tristimulus projection colorimeter has been developed. The calorimeter operates with easily interchangeable sets of primary color filters placed in a frame at the objective. The apparatus has proved to be fairly accurate. The reproduction of the color matches as measured by the standard deviation is equal to the visual sensitivity to color differences for each observer. Examples of deviations in the matches among individuals as well as deviations compared with the CIE 1931 Standard Observer are given. These deviations are demonstrated to be solely due to individual differences in the perception of metameric colors. Thus, taking advantage of an objective observation (allowing all adjustments to be judged by a group of impartial observers), the colorimeter provides an excellent aid in the study of discrimination, metamerism, and related effects which are of considerable interest in current research in colorimetry and in the study of color vision tests.
Discriminating crop and other canopies by overlapping binary image layers
NASA Astrophysics Data System (ADS)
Doi, Ryoichi
2013-02-01
For optimal management of agricultural fields by remote sensing, discrimination of the crop canopy from weeds and other objects is essential. In a digital photograph, a rice canopy was discriminated from a variety of weed and tree canopies and other objects by overlapping binary image layers of red-green-blue and other color components indicating the pixels with target canopy-specific (intensity) values based on the ranges of means ±(3×) standard deviations. By overlapping and merging the binary image layers, the target canopy specificity improved to 0.0015 from 0.027 for the yellow 1× standard deviation binary image layer, which was the best among all combinations of color components and means ±(3×) standard deviations. The most target rice canopy-likely pixels were further identified by limiting the pixels at different luminosity values. The discriminatory power was also visually demonstrated in this manner.
Middle school transition and body weight outcomes: Evidence from Arkansas Public Schoolchildren.
Zeng, Di; Thomsen, Michael R; Nayga, Rodolfo M; Rouse, Heather L
2016-05-01
There is evidence that middle school transition adversely affects educational and psychological outcomes of pre-teen children, but little is known about the impacts of middle school transition on other aspects of health. In this article, we estimate the impact of middle school transition on the body mass index (BMI) of public schoolchildren in Arkansas, United States. Using an instrumental variable approach, we find that middle school transition in grade 6 led to a moderate decrease of 0.04 standard deviations in BMI z-scores for all students. Analysis by subsample indicated that this result was driven by boys (0.06-0.07 standard deviations) and especially by non-minority boys (0.09 standard deviations). We speculate that the changing levels of physical activities associated with middle school transition provide the most reasonable explanation for this result. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
Migration in the shearing sheet and estimates for young open cluster migration
NASA Astrophysics Data System (ADS)
Quillen, Alice C.; Nolting, Eric; Minchev, Ivan; De Silva, Gayandhi; Chiappini, Cristina
2018-04-01
Using tracer particles embedded in self-gravitating shearing sheet N-body simulations, we investigate the distance in guiding centre radius that stars or star clusters can migrate in a few orbital periods. The standard deviations of guiding centre distributions and maximum migration distances depend on the Toomre or critical wavelength and the contrast in mass surface density caused by spiral structure. Comparison between our simulations and estimated guiding radii for a few young supersolar metallicity open clusters, including NGC 6583, suggests that the contrast in mass surface density in the solar neighbourhood has standard deviation (in the surface density distribution) divided by mean of about 1/4 and larger than measured using COBE data by Drimmel and Spergel. Our estimate is consistent with a standard deviation of ˜0.07 dex in the metallicities measured from high-quality spectroscopic data for 38 young open clusters (<1 Gyr) with mean galactocentric radius 7-9 kpc.
Jafarov, E. E.; Parsekian, A. D.; Schaefer, K.; ...
2018-01-09
Ground penetrating radar (GPR) has emerged as an effective tool for estimating active layer thickness (ALT) and volumetric water content (VWC) within the active layer. In August 2013, we conducted a series of GPR and probing surveys using a 500 MHz antenna and metallic probe around Barrow, Alaska. Here, we collected about 15 km of GPR data and 1.5 km of probing data. We describe the GPR data processing workflow from raw GPR data to the estimated ALT and VWC. We then include the corresponding uncertainties for each measured and estimated parameter. The estimated average GPR-derived ALT was 41 cm,more » with a standard deviation of 9 cm. The average probed ALT was 40 cm, with a standard deviation of 12 cm. The average GPR-derived VWC was 0.65, with a standard deviation of 0.14.« less
The Cost of Uncertain Life Span*
Edwards, Ryan D.
2012-01-01
A considerable amount of uncertainty surrounds the length of human life. The standard deviation in adult life span is about 15 years in the U.S., and theory and evidence suggest it is costly. I calibrate a utility-theoretic model of preferences over length of life and show that one fewer year in standard deviation is worth about half a mean life year. Differences in the standard deviation exacerbate cross-sectional differences in life expectancy between the U.S. and other industrialized countries, between rich and poor countries, and among poor countries. Accounting for the cost of life-span variance also appears to amplify recently discovered patterns of convergence in world average human well-being. This is partly for methodological reasons and partly because unconditional variance in human length of life, primarily the component due to infant mortality, has exhibited even more convergence than life expectancy. PMID:22368324
On the linear relation between the mean and the standard deviation of a response time distribution.
Wagenmakers, Eric-Jan; Brown, Scott
2007-07-01
Although it is generally accepted that the spread of a response time (RT) distribution increases with the mean, the precise nature of this relation remains relatively unexplored. The authors show that in several descriptive RT distributions, the standard deviation increases linearly with the mean. Results from a wide range of tasks from different experimental paradigms support a linear relation between RT mean and RT standard deviation. Both R. Ratcliff's (1978) diffusion model and G. D. Logan's (1988) instance theory of automatization provide explanations for this linear relation. The authors identify and discuss 3 specific boundary conditions for the linear law to hold. The law constrains RT models and supports the use of the coefficient of variation to (a) compare variability while controlling for differences in baseline speed of processing and (b) assess whether changes in performance with practice are due to quantitative speedup or qualitative reorganization. Copyright 2007 APA.
Determination of the optimal level for combining area and yield estimates
NASA Technical Reports Server (NTRS)
Bauer, M. E. (Principal Investigator); Hixson, M. M.; Jobusch, C. D.
1981-01-01
Several levels of obtaining both area and yield estimates of corn and soybeans in Iowa were considered: county, refined strata, refined/split strata, crop reporting district, and state. Using the CCEA model form and smoothed weather data, regression coefficients at each level were derived to compute yield and its variance. Variances were also computed with stratum level. The variance of the yield estimates was largest at the state and smallest at the county level for both crops. The refined strata had somewhat larger variances than those associated with the refined/split strata and CRD. For production estimates, the difference in standard deviations among levels was not large for corn, but for soybeans the standard deviation at the state level was more than 50% greater than for the other levels. The refined strata had the smallest standard deviations. The county level was not considered in evaluation of production estimates due to lack of county area variances.
Quantifying relative importance: Computing standardized effects in models with binary outcomes
Grace, James B.; Johnson, Darren; Lefcheck, Jonathan S.; Byrnes, Jarrett E.K.
2018-01-01
Results from simulation studies show that both the LT and OE methods of standardization support a similarly-broad range of coefficient comparisons. The LT method estimates effects that reflect underlying latent-linear propensities, while the OE method computes a linear approximation for the effects of predictors on binary responses. The contrast between assumptions for the two methods is reflected in persistently weaker standardized effects associated with OE standardization. Reliance on standard deviations for standardization (the traditional approach) is critically examined and shown to introduce substantial biases when predictors are non-Gaussian. The use of relevant ranges in place of standard deviations has the capacity to place LT and OE standardized coefficients on a more comparable scale. As ecologists address increasingly complex hypotheses, especially those that involve comparing the influences of different controlling factors (e.g., top-down versus bottom-up or biotic versus abiotic controls), comparable coefficients become a necessary component for evaluations.
Boone, J Scott; Guan, Bing; Vigo, Craig; Boone, Tripp; Byrne, Christian; Ferrario, Joseph
2014-06-06
A trace analytical method was developed for the determination of seventeen specific perfluorinated chemicals (PFCs) in environmental and drinking waters. The objectives were to optimize an isotope-dilution method to increase the precision and accuracy of the analysis of the PFCs and to eliminate the need for matrix-matched standards. A 250 mL sample of environmental or drinking water was buffered to a pH of 4, spiked with labeled surrogate standards, extracted through solid phase extraction cartridges, and eluted with ammonium hydroxide in methyl tert-butyl ether: methanol solution. The sample eluents were concentrated to volume and analyzed by liquid chromatography/tandem mass spectrometry (LC-MS/MS). The lowest concentration minimal reporting levels (LCMRLs) for the seventeen PFCs were calculated and ranged from 0.034 to 0.600 ng/L for surface water and from 0.033 to 0.640 ng/L for drinking water. The relative standard deviations (RSDs) for all compounds were <20% for all concentrations above the LCMRL. The method proved effective and cost efficient and addressed the problems with the recovery of perfluorobutanoic acid (PFBA) and other short chain PFCs. Various surface water and drinking water samples were used during method development to optimize this method. The method was used to evaluate samples from the Mississippi River at New Orleans and drinking water samples from a private residence in that same city. The method was also used to determine PFC contamination in well water samples from a fire training area where perfluorinated foams were used in training to extinguish fires. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Prentice, Boone M.; Chumbley, Chad W.; Caprioli, Richard M.
2017-01-01
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%.
NASA Astrophysics Data System (ADS)
Raghu, M. S.; Basavaiah, K.; Ramesh, P. J.; Abdulrahman, Sameer A. M.; Vinay, K. B.
2012-03-01
A sensitive, precise, and cost-effective UV-spectrophotometric method is described for the determination of pheniramine maleate (PAM) in bulk drug and tablets. The method is based on the measurement of absorbance of a PAM solution in 0.1 N HCl at 264 nm. As per the International Conference on Harmonization (ICH) guidelines, the method was validated for linearity, accuracy, precision, limits of detection (LOD) and quantification (LOQ), and robustness and ruggedness. A linear relationship between absorbance and concentration of PAM in the range of 2-40 μg/ml with a correlation coefficient (r) of 0.9998 was obtained. The LOD and LOQ values were found to be 0.18 and 0.39 μg/ml PAM, respectively. The precision of the method was satisfactory: the value of relative standard deviation (RSD) did not exceed 3.47%. The proposed method was applied successfully to the determination of PAM in tablets with good accuracy and precision. Percentages of the label claims ranged from 101.8 to 102.01% with the standard deviation (SD) from 0.64 to 0.72%. The accuracy of the method was further ascertained by recovery studies via a standard addition procedure. In addition, the forced degradation of PAM was conducted in accordance with the ICH guidelines. Acidic and basic hydrolysis, thermal stress, peroxide, and photolytic degradation were used to assess the stability-indicating power of the method. A substantial degradation was observed during oxidative and alkaline degradations. No degradation was observed under other stress conditions.
Color reproducibility and dyestuff concentration
NASA Astrophysics Data System (ADS)
Csanyi, Sandor
2002-06-01
The purpose of this study was to develop a new sensitivity index connected with color matching, which makes it possible to investigate the effects of dyestuff concentration deviations in a larger part of the color space in a comprehensive manner. By the help of computer simulation and experimental design, we examined the color differences resulting from minor concentration changes in approximately 500 formulas of different compositions, altering their total concentration and the proportion of the individual dyes in them. The new sensitivity index makes it possible for the colorist to select the recipe that is the least sensitive to concentration deviations from among the computer color formulas, as well as to add a new aspect to the ranking applied in color matching so far.
Mazumder, Avik; Gupta, Hemendra K; Garg, Prabhat; Jain, Rajeev; Dubey, Devendra K
2009-07-03
This paper details an on-flow liquid chromatography-ultraviolet-nuclear magnetic resonance (LC-UV-NMR) method for the retrospective detection and identification of alkyl alkylphosphonic acids (AAPAs) and alkylphosphonic acids (APAs), the markers of the toxic nerve agents for verification of the Chemical Weapons Convention (CWC). Initially, the LC-UV-NMR parameters were optimized for benzyl derivatives of the APAs and AAPAs. The optimized parameters include stationary phase C(18), mobile phase methanol:water 78:22 (v/v), UV detection at 268nm and (1)H NMR acquisition conditions. The protocol described herein allowed the detection of analytes through acquisition of high quality NMR spectra from the aqueous solution of the APAs and AAPAs with high concentrations of interfering background chemicals which have been removed by preceding sample preparation. The reported standard deviation for the quantification is related to the UV detector which showed relative standard deviations (RSDs) for quantification within +/-1.1%, while lower limit of detection upto 16mug (in mug absolute) for the NMR detector. Finally the developed LC-UV-NMR method was applied to identify the APAs and AAPAs in real water samples, consequent to solid phase extraction and derivatization. The method is fast (total experiment time approximately 2h), sensitive, rugged and efficient.
Wang, Yalong; Jiang, Han; Huang, Huizhi; Xie, Yanqi; Zhao, Yunshi; You, Xiuhua; Tang, Lipeng; Wang, Youqiong; Yin, Wei; Qiu, Pengxin; Yan, Guangmei; Hu, Haiyan
2015-03-01
So far, the components responsible for the neuroprotective effects of Calculus bovis are unclear. Cholesterol, one of the major components in Calculus bovis, is easily oxidized into oxysterols, which possess direct or indirect neuroprotective effects proved by our and others' previous studies. Therefore, a liquid chromatography with mass spectrometry method coupled with ultrasonic extraction and solid-phase extraction was developed for the determination of neuroprotective oxysterols in Calculus bovis, human gallstones, and traditional Chinese medicine preparations. Chromatographic separation was achieved on a C18 column with isocratic elution at a flow rate of 1 mL/min. The established method showed good linearity (R(2) > 0.998), sensitivity with low limits of detection (0.06-0.39 μg/g), acceptable precisions (relative standard deviations ≤ 7.4%), stability (relative standard deviations ≤ 5.9%), and satisfactory accuracy (92.4-102.9%) for all analytes identified by different retention times, which could be applied for the determination of oxysterols. Five kinds of oxysterols proved to function as neuroprotectants were detected at different concentrations. Among them, 7β-hydroxycholesterol and cholestane-3β,5α,6β-triol were rather abundant in the samples. It could be concluded that the potential neuroprotective components in Calculus bovis may be these oxysterols. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Lily; Laila, L.; Prasetyo, B. E.
2018-03-01
A selective, reproducibility, effective, sensitive, simple and fast High-Performance Liquid Chromatography (HPLC) was developed, optimized and validated to analyze 25-Desacetyl Rifampicin (25-DR) in human urine which is from tuberculosis patient. The separation was performed by HPLC Agilent Technologies with column Agilent Eclipse XDB- Ci8 and amobile phase of 65:35 v/v methanol: 0.01 M sodium phosphate buffer pH 5.2, at 254 nm and flow rate of 0.8ml/min. The mean retention time was 3.016minutes. The method was linear from 2–10μg/ml 25-DR with a correlation coefficient of 0.9978. Standard deviation, relative standard deviation and coefficient variation of 2, 6, 10μg/ml 25-DR were 0-0.0829, 03.1752, 0-0.0317%, respectively. The recovery of 5, 7, 9μg/ml25-DR was 80.8661, 91.3480 and 111.1457%, respectively. Limits of detection (LoD) and quantification (LoQ) were 0.51 and 1.7μg/ml, respectively. The method has fulfilled the validity guidelines of the International Conference on Harmonization (ICH) bioanalytical method which includes parameters of specificity, linearity, precision, accuracy, LoD, and LoQ. The developed method is suitable for pharmacokinetic analysis of various concentrations of 25-DR in human urine.