Niu, Lili; Zhang, Yanling; Qian, Ming; Xiao, Yang; Meng, Long; Zheng, Rongqin; Zheng, Hairong
2017-11-01
The stiffness of large arteries and the presence or absence of plaque are associated with coronary heart disease (CHD). Because arterial walls are biologically heterogeneous, the standard deviation of Young's modulus (YM-std) of the large arteries may better predict coronary atherosclerosis. However, the role of YM-std in the occurrence of coronary events has not been addressed so far. Therefore, this study investigated whether the carotid YM-std and the presence or absence of plaque improved CHD risk prediction. One hundred and three patients with CHD (age 66 ± 11 years) and 107 patients at high risk of atherosclerosis (age 61 ± 7 years) were recruited. Carotid YM was measured by the vessel texture matching method, and YM-std was calculated. Carotid intima-media thickness was measured by the MyLab 90 ultrasound Platform employed dedicated software RF-tracking technology. In logistic regression analysis, YM-std (OR = 1·010; 95% CI = 1·003-1·016), carotid plaque (OR = 16·759; 95% CI = 3·719-75·533) and YM-std plus plaque (OR = 0·989; 95% CI = 0·981-0·997) were independent predictors of CHD. The traditional risk factors (TRF) plus YM-std plus plaque model showed a significant improvement in area under the receiver-operating characteristic curve (AUC), which increased from 0·717 (TRF only) to 0·777 (95% CI for the difference in adjusted AUC: 0·010-0·110). Carotid YM-std is a powerful independent predictor of CHD. Adding plaque and YM-std to TRF improves CHD risk prediction. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu; Brinkmann, Debra H.; Ward, Shelly B.
2013-03-15
Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the secondmore » (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.« less
Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A
2013-03-15
This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Pitoňák, Martin; Šprlák, Michal; Tenzer, Robert
2017-05-01
We investigate a numerical performance of four different schemes applied to a regional recovery of the gravity anomalies from the third-order gravitational tensor components (assumed to be observable in the future) synthetized at the satellite altitude of 200 km above the mean sphere. The first approach is based on applying a regional inversion without modelling the far-zone contribution or long-wavelength support. In the second approach we separate integral formulas into two parts, that is, the effects of the third-order disturbing tensor data within near and far zones. Whereas the far-zone contribution is evaluated by using existing global geopotential model (GGM) with spectral weights given by truncation error coefficients, the near-zone contribution is solved by applying a regional inversion. We then extend this approach for a smoothing procedure, in which we remove the gravitational contributions of the topographic-isostatic and atmospheric masses. Finally, we apply the remove-compute-restore (r-c-r) scheme in order to reduce the far-zone contribution by subtracting the reference (long-wavelength) gravity field, which is computed for maximum degree 80. We apply these four numerical schemes to a regional recovery of the gravity anomalies from individual components of the third-order gravitational tensor as well as from their combinations, while applying two different levels of a white noise. We validated our results with respect to gravity anomalies evaluated at the mean sphere from EGM2008 up to the degree 250. Not surprisingly, better fit in terms of standard deviation (STD) was attained using lower level of noise. The worst results were gained applying classical approach, STD values of our solution from Tzzz are 1.705 mGal (noise value with a standard deviation 0.01 × 10 - 15m - 1s - 2) and 2.005 mGal (noise value with a standard deviation 0.05 × 10 - 15m - 1s - 2), while the superior from r-c-r up to the degree 80, STD fit of gravity anomalies from Tzzz with respect to the same counterpart from EGM2008 is 0.510 mGal (noise value with a standard deviation 0.01 × 10 - 15m - 1s - 2) and 1.190 mGal (noise value with a standard deviation 0.05 × 10 - 15m - 1s - 2).
NCL script: cmaq_ensemble_isam_4panels_subdomain.nclNetcdf input file for NCL script, containing ensemble means and standard deviation of ISAM SO4 and O3 contributions from IPM: test.ncPlot (ps): maps_isam_mean_std_lasthour_ipm_so4_o3_east.psPlot (pdf): maps_isam_mean_std_lasthour_ipm_so4_o3_east.pdfPlot (ncgm): maps_isam_mean_std_lasthour_ipm_so4_o3_east.ncgmThis dataset is associated with the following publication:Gilliam , R., C. Hogrefe , J. Godowitch, S. Napelenok , R. Mathur , and S.T. Rao. Impact of inherent meteorology uncertainty on air quality model predictions. JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES. American Geophysical Union, Washington, DC, USA, 120(23): 12,259–12,280, (2015).
Incremental Sampling Methodology (ISM) for Metallic Residues
2013-08-01
Deviation (also %RSD) Sb Antimony Sn Tin Sr Strontium STD Standard Deviation ERDC TR-13-5 x SU Sampling Unit Ti Titanium UCL Upper Confidence Limit...Ce), chromium (Cr), Cu, Fe, Pb, mag- nesium (Mg), Mn, potassium (K), sodium (Na), strontium (Sr), titanium (Ti), W, zirconium (Zr), and Zn (Clausen...wastes. A proposed alternative to EPA SW 846 Method 3050. Environmental Science and Technology 23: 89 −900. Matzke, B., N. Hassig, J. Wilson, R. Gilber
Multi-sensor Improved Sea-Surface Temperature (MISST) for IOOS - Navy Component
2013-09-30
application and data fusion techniques. 2. Parameterization of IR and MW retrieval differences, with consideration of diurnal warming and cool-skin effects...associated retrieval confidence, standard deviation (STD), and diurnal warming estimates to the application user community in the new GDS 2.0 GHRSST...including coral reefs, ocean modeling in the Gulf of Mexico, improved lake temperatures, numerical data assimilation by ocean models, numerical
40 CFR 1066.630 - PDP, SSV, and CFV flow rate calculations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... per revolution, as determined in paragraph (a)(2) of this section. T std = standard temperature = 293.... p std = standard pressure= 101.325 kPa. (2) Calculate V rev using the following equation: ER28AP14... std = standard temperature. p std = standard pressure. Z = compressibility factor. M mix = molar mass...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakhtiari, M; Schmitt, J; Sarfaraz, M
2015-06-15
Purpose: To establish a minimum number of patients required to obtain statistically accurate Planning Target Volume (PTV) margins for prostate Intensity Modulated Radiation Therapy (IMRT). Methods: A total of 320 prostate patients, consisting of a total number of 9311 daily setups, were analyzed. These patients had gone under IMRT treatments. Daily localization was done using the skin marks and the proper shifts were determined by the CBCT to match the prostate gland. The Van Herk formalism is used to obtain the margins using the systematic and random setup variations. The total patient population was divided into different grouping sizes varyingmore » from 1 group of 320 patients to 64 groups of 5 patients. Each grouping was used to determine the average PTV margin and its associated standard deviation. Results: Analyzing all 320 patients lead to an average Superior-Inferior margin of 1.15 cm. The grouping with 10 patients per group (32 groups) resulted to an average PTV margin between 0.6–1.7 cm with the mean value of 1.09 cm and a standard deviation (STD) of 0.30 cm. As the number of patients in groups increases the mean value of average margin between groups tends to converge to the true average PTV of 1.15 cm and STD decreases. For groups of 20, 64, and 160 patients a Superior-Inferior margin of 1.12, 1.14, and 1.16 cm with STD of 0.22, 0.11, and 0.01 cm were found, respectively. Similar tendency was observed for Left-Right and Anterior-Posterior margins. Conclusion: The estimation of the required margin for PTV strongly depends on the number of patients studied. According to this study at least ∼60 patients are needed to calculate a statistically acceptable PTV margin for a criterion of STD < 0.1 cm. Numbers greater than ∼60 patients do little to increase the accuracy of the PTV margin estimation.« less
NASA-STD-3001, Space Flight Human-System Standard and the Human Integration Design Handbook
NASA Technical Reports Server (NTRS)
Whitmore, Mihriban; Boyer, Jennifer; Holubec, Keith
2012-01-01
NASA-STD-3001 Space Flight Human-System Standard Volume 1, Crew Health, Volume 2, Human Factors, Habitability and Environmental Health, and the Human Integration Design Handbook (HIDH) have replaced the Man-Systems Integration Standards (MSIS), NASA-STD-3000. For decades, NASA-STD-3000 was a significant contribution to human spaceflight programs and to human-systems integration. However, with research program and project results being realized, advances in technology, and the availability of new information in a variety of topic areas, the time had arrived to update this extensive suite of standards and design information. NASA-STD-3001, Volume 2 contains the Agency level standards from the human and environmental factors disciplines that ensure human spaceflight operations are performed safely, efficiently, and effectively. The HIDH is organized in the same sequence and serves as the companion document to NASA-STD-3001, Volume 2, providing a compendium of human spaceflight history and knowledge. The HIDH is intended to aid interpretation of NASA-STD-3001, Volume 2 standards and to provide guidance for requirement writers and vehicle and habitat designers. Keywords Human Factors, Standards, Environmental Factors, NASA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohkubo, Masaki, E-mail: mook@clg.niigata-u.ac.jp
Purpose: In lung cancer computed tomography (CT) screening, the performance of a computer-aided detection (CAD) system depends on the selection of the image reconstruction kernel. To reduce this dependence on reconstruction kernels, the authors propose a novel application of an image filtering method previously proposed by their group. Methods: The proposed filtering process uses the ratio of modulation transfer functions (MTFs) of two reconstruction kernels as a filtering function in the spatial-frequency domain. This method is referred to as MTF{sub ratio} filtering. Test image data were obtained from CT screening scans of 67 subjects who each had one nodule. Imagesmore » were reconstructed using two kernels: f{sub STD} (for standard lung imaging) and f{sub SHARP} (for sharp edge-enhancement lung imaging). The MTF{sub ratio} filtering was implemented using the MTFs measured for those kernels and was applied to the reconstructed f{sub SHARP} images to obtain images that were similar to the f{sub STD} images. A mean filter and a median filter were applied (separately) for comparison. All reconstructed and filtered images were processed using their prototype CAD system. Results: The MTF{sub ratio} filtered images showed excellent agreement with the f{sub STD} images. The standard deviation for the difference between these images was very small, ∼6.0 Hounsfield units (HU). However, the mean and median filtered images showed larger differences of ∼48.1 and ∼57.9 HU from the f{sub STD} images, respectively. The free-response receiver operating characteristic (FROC) curve for the f{sub SHARP} images indicated poorer performance compared with the FROC curve for the f{sub STD} images. The FROC curve for the MTF{sub ratio} filtered images was equivalent to the curve for the f{sub STD} images. However, this similarity was not achieved by using the mean filter or median filter. Conclusions: The accuracy of MTF{sub ratio} image filtering was verified and the method was demonstrated to be effective for reducing the kernel dependence of CAD performance.« less
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
40 CFR 1037.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equations: (1) For vocational vehicles: Emission credits (Mg) = (Std-FEL) × (Payload Tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard associated with the specific tractor regulatory subcategory... credits (Mg) = (Std-FEL) × (Payload tons) × (Volume) × (UL) × (10−6) Where: Std = the emission standard...
NASA Astrophysics Data System (ADS)
Ang, W. C.; Hashim, S.; Karim, M. K. A.; Bahruddin, N. A.; Salehhon, N.; Musa, Y.
2017-05-01
The widespread use of computed tomography (CT) has increased the medical radiation exposure and cancer risk. We aimed to evaluate the impact of AIDR 3D in CT abdomen-pelvic examinations based on image quality and radiation dose in low dose (LD) setting compared to standard dose (STD) with filtered back projection (FBP) reconstruction. We retrospectively reviewed the images of 40 patients who underwent CT abdomen-pelvic using a 80 slice CT scanner. Group 1 patients (n=20, mean age 41 ± 17 years) were performed at LD with AIDR 3D reconstruction and Group 2 patients (n=20, mean age 52 ± 21 years) were scanned with STD using FBP reconstruction. Objective image noise was assessed by region of interest (ROI) measurements in the liver and aorta as standard deviation (SD) of the attenuation value (Hounsfield Unit, HU) while subjective image quality was evaluated by two radiologists. Statistical analysis was used to compare the scan length, CT dose index volume (CTDIvol) and image quality of both patient groups. Although both groups have similar mean scan length, the CTDIvol significantly decreased by 38% in LD CT compared to STD CT (p<0.05). Objective and subjective image quality were statistically improved with AIDR 3D (p<0.05). In conclusion, AIDR 3D enables significant dose reduction of 38% with superior image quality in LD CT abdomen-pelvis.
NASA Astrophysics Data System (ADS)
Eck, Brendan; Fahmi, Rachid; Brown, Kevin M.; Raihani, Nilgoun; Wilson, David L.
2014-03-01
Model observers were created and compared to human observers for the detection of low contrast targets in computed tomography (CT) images reconstructed with an advanced, knowledge-based, iterative image reconstruction method for low x-ray dose imaging. A 5-channel Laguerre-Gauss Hotelling Observer (CHO) was used with internal noise added to the decision variable (DV) and/or channel outputs (CO). Models were defined by parameters: (k1) DV-noise with standard deviation (std) proportional to DV std; (k2) DV-noise with constant std; (k3) CO-noise with constant std across channels; and (k4) CO-noise in each channel with std proportional to CO variance. Four-alternative forced choice (4AFC) human observer studies were performed on sub-images extracted from phantom images with and without a "pin" target. Model parameters were estimated using maximum likelihood comparison to human probability correct (PC) data. PC in human and all model observers increased with dose, contrast, and size, and was much higher for advanced iterative reconstruction (IMR) as compared to filtered back projection (FBP). Detection in IMR was better than FPB at 1/3 dose, suggesting significant dose savings. Model(k1,k2,k3,k4) gave the best overall fit to humans across independent variables (dose, size, contrast, and reconstruction) at fixed display window. However Model(k1) performed better when considering model complexity using the Akaike information criterion. Model(k1) fit the extraordinary detectability difference between IMR and FBP, despite the different noise quality. It is anticipated that the model observer will predict results from iterative reconstruction methods having similar noise characteristics, enabling rapid comparison of methods.
A Journey in Standard Development: The Core Manufacturing Simulation Data (CMSD) Information Model.
Lee, Yung-Tsun Tina
2015-01-01
This report documents a journey "from research to an approved standard" of a NIST-led standard development activity. That standard, Core Manufacturing Simulation Data (CMSD) information model, provides neutral structures for the efficient exchange of manufacturing data in a simulation environment. The model was standardized under the auspices of the international Simulation Interoperability Standards Organization (SISO). NIST started the research in 2001 and initiated the standardization effort in 2004. The CMSD standard was published in two SISO Products. In the first Product, the information model was defined in the Unified Modeling Language (UML) and published in 2010 as SISO-STD-008-2010. In the second Product, the information model was defined in Extensible Markup Language (XML) and published in 2013 as SISO-STD-008-01-2012. Both SISO-STD-008-2010 and SISO-STD-008-01-2012 are intended to be used together.
Quantitative diagnostic method for biceps long head tendinitis by using ultrasound.
Huang, Shih-Wei; Wang, Wei-Te
2013-01-01
To investigate the feasibility of grayscale quantitative diagnostic method for biceps tendinitis and determine the cut-off points of a quantitative biceps ultrasound (US) method to diagnose biceps tendinitis. Design. Prospective cross-sectional case controlled study. Outpatient rehabilitation service. A total of 336 shoulder pain patients with suspected biceps tendinitis were recruited in this prospective observational study. The grayscale pixel data of the range of interest (ROI) were obtained for both the transverse and longitudinal views of the biceps US. A total of 136 patients were classified with biceps tendinitis, and 200 patients were classified as not having biceps tendinitis based on the diagnostic criteria. Based on the Youden index, the cut-off points were determined as 26.85 for the transverse view and 21.25 for the longitudinal view of the standard deviation (StdDev) of the ROI values, respectively. When the ROI evaluation of the US surpassed the cut-off point, the sensitivity was 68% and the specificity was 90% in the StdDev of the transverse view, and the sensitivity was 81% and the specificity was 73% in the StdDev of the longitudinal view to diagnose biceps tendinitis. For equivocal cases or inexperienced sonographers, our study provides a more objective method for diagnosing biceps tendinitis in shoulder pain patients.
46 CFR 45.65 - Excess sheer limitations.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Midship 1 _______ Sum of Aft Products After Standard Sheer .2665L+26.651 _______ Difference: Sum-STD... 1 _______ Sum of Fwd Products Fwd Standard Sheer .5330L+53.301 _______ Difference: Sum-STD...
46 CFR 45.65 - Excess sheer limitations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Midship 1 _______ Sum of Aft Products After Standard Sheer .2665L+26.651 _______ Difference: Sum-STD... 1 _______ Sum of Fwd Products Fwd Standard Sheer .5330L+53.301 _______ Difference: Sum-STD...
46 CFR 45.65 - Excess sheer limitations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Midship 1 _______ Sum of Aft Products After Standard Sheer .2665L+26.651 _______ Difference: Sum-STD... 1 _______ Sum of Fwd Products Fwd Standard Sheer .5330L+53.301 _______ Difference: Sum-STD...
46 CFR 45.65 - Excess sheer limitations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Midship 1 _______ Sum of Aft Products After Standard Sheer .2665L+26.651 _______ Difference: Sum-STD... 1 _______ Sum of Fwd Products Fwd Standard Sheer .5330L+53.301 _______ Difference: Sum-STD...
46 CFR 45.65 - Excess sheer limitations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Midship 1 _______ Sum of Aft Products After Standard Sheer .2665L+26.651 _______ Difference: Sum-STD... 1 _______ Sum of Fwd Products Fwd Standard Sheer .5330L+53.301 _______ Difference: Sum-STD...
NASA Astrophysics Data System (ADS)
Martin, Olivier A.; Correia, Carlos M.; Gendron, Eric; Rousset, Gerard; Gratadour, Damien; Vidal, Fabrice; Morris, Tim J.; Basden, Alastair G.; Myers, Richard M.; Neichel, Benoit; Fusco, Thierry
2016-10-01
In preparation of future multiobject spectrographs (MOS) whose one of the major role is to provide an extensive statistical studies of high redshifted galaxies surveyed, the demonstrator CANARY has been designed to tackle technical challenges related to open-loop adaptive optics (AO) control with jointed Natural Guide Star and Laser Guide Star tomography. We have developed a point spread function (PSF) reconstruction algorithm dedicated to multiobject adaptive optics systems using system telemetry to estimate the PSF potentially anywhere in the observed field, a prerequisite to postprocess AO-corrected observations in integral field spectroscopy. We show how to handle off-axis data to estimate the PSF using atmospheric tomography and compare it to a classical approach that uses on-axis residual phase from a truth sensor observing a natural bright source. We have reconstructed over 450 on-sky CANARY PSFs and we get bias/1-σ standard-deviation (std) of 1.3/4.8 on the H-band Strehl ratio (SR) with 92.3% of correlation between reconstructed and sky SR. On the full-width at half-maximum, we get, respectively, 2.94 mas, 19.9 mas, and 88.3% for the bias, std, and correlation. The reference method achieves 0.4/3.5/95% on the SR and 2.71 mas/14.9 mas/92.5% on the FWHM for the bias/std/correlation.
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2013 CFR
2013-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2014 CFR
2014-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2011 CFR
2011-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
40 CFR 211.206-2 - Alternative test data.
Code of Federal Regulations, 2012 CFR
2012-07-01
... according to ANSI STD Z24.22-1957 or ANSI STD S3.19-1974 to determine the mean attenuation and standard... based on the ANSI STD Z24.22-1957 measurement procedure must state in the supporting information... are based on ANSI STD -Z24.22-1957. (b) Manufacturers who initially use available data based on ANSI...
Development and Evaluation of a Multimedia-Enhanced STD/HIV Curriculum for Middle Schools
ERIC Educational Resources Information Center
Goldsworthy, Richard; Schwartz, Nancy
2008-01-01
STD infection among adolescents is a significant public health concern. Surveys indicate that parents believe STD and HIV/AIDS are appropriate topics for middle school and high school students; however, school-based STD education efforts remain inconsistent, perhaps in part as a result of the lack of standardized, well-distributed curricula.…
Ordered versus Unordered Map for Primitive Data Types
2015-09-01
mapped to some element. C++ provides two types of map containers within the standard template library, the std ::map and the std ::unordered_map...classes. As the name implies, the containers main functional difference is that the elements in the std ::map are ordered by the key, and the std ...unordered_map are not ordered based on their key. The std ::unordered_map elements are placed into “buckets” based on a hash value computed for their key
Technical efficiency of public district hospitals and health centres in Ghana: a pilot study
Osei, Daniel; d'Almeida, Selassi; George, Melvill O; Kirigia, Joses M; Mensah, Ayayi Omar; Kainyu, Lenity H
2005-01-01
Background The Government of Ghana has been implementing various health sector reforms (e.g. user fees in public health facilities, decentralization, sector-wide approaches to donor coordination) in a bid to improve efficiency in health care. However, to date, except for the pilot study reported in this paper, no attempt has been made to make an estimate of the efficiency of hospitals and/or health centres in Ghana. The objectives of this study, based on data collected in 2000, were: (i) to estimate the relative technical efficiency (TE) and scale efficiency (SE) of a sample of public hospitals and health centres in Ghana; and (ii) to demonstrate policy implications for health sector policy-makers. Methods The Data Envelopment Analysis (DEA) approach was used to estimate the efficiency of 17 district hospitals and 17 health centres. This was an exploratory study. Results Eight (47%) hospitals were technically inefficient, with an average TE score of 61% and a standard deviation (STD) of 12%. Ten (59%) hospitals were scale inefficient, manifesting an average SE of 81% (STD = 25%). Out of the 17 health centres, 3 (18%) were technically inefficient, with a mean TE score of 49% (STD = 27%). Eight health centres (47%) were scale inefficient, with an average SE score of 84% (STD = 16%). Conclusion This pilot study demonstrated to policy-makers the versatility of DEA in measuring inefficiencies among individual facilities and inputs. There is a need for the Planning and Budgeting Unit of the Ghana Health Services to continually monitor the productivity growth, allocative efficiency and technical efficiency of all its health facilities (hospitals and health centres) in the course of the implementation of health sector reforms. PMID:16188021
Comparison of RFFIT tests with different standard sera and testing procedures.
Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong
2012-06-01
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.
40 CFR 80.1405 - What are the Renewable Fuel Standards?
Code of Federal Regulations, 2011 CFR
2011-07-01
... Renewable Fuel Standards? (a) Renewable Fuel Standards for 2011. (1) The value of the cellulosic biofuel... be 0.69 percent. (3) The value of the advanced biofuel standard for 2011 shall be 0.78 percent. (4... ER10MY10.003 ER10MY10.004 Where: StdCB,i = The cellulosic biofuel standard for year i, in percent. StdBBD,i...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stanley, D; Papanikolaou, N; Gutierrez, A
2015-06-15
Introduction Quality assurance of the image quality for image guided localization systems is crucial to ensure accurate visualization and localization of target volumes. In this study, the long term stability of selected image parameters was assessed and evaluated for CBCT mode, planar radiographic kV mode and MV mode. Methods and Materials: The CATPHAN, QckV-1 and QC-3 phantoms were used to evaluate the image quality parameters. The planar radiographic images were analyzed in PIPSpro™ with spatial resolution (f30, f40, f50) being recorded. For XVI CBCT, Head and Neck Small20 (S20) and Pelvis Medium20 (M20) standard acquisition modes were evaluated for Uniformity,more » Noise, Spatial Resolution and HU constancy. Dose and kVp for the XVI were recorded using the Unfors RaySafe Xi system with the R/F Low Detector for the kV planar radiographic mode. Results A total of 20 and 10 measurements were acquired for the planar radiographic and CBCT systems respectively over a two month period. Values were normalized to the mean and the standard deviations (STD) were recorded. For the planar radiographic spatial resolution, the STD for f30, f40, f50 were 0.004, 0.002, 0.002 and 0.005, 0.007, 0.008 for the kV and MV, respectively. The average recorded dose for kV was 38.7±2.7 μGy. The STD of the evaluated metrics for the S20 acquisition were: 0.444(f30), 0.067(f40), 0.062(f50), 0.018(Water/poly-HU constancy), 0.028(uniformity) and 0.106(noise). The standard deviations for the M20 acquisition were: 0.108(f30), 0.073(f40), 0.091(f50), 0.008(Water/poly-HU constancy), 0.005(uniformity) and 0.005(noise). Using these, tolerances can be reported as a warning and action threshold of 1σ and 2σ. Conclusion A study was performed to assess the stability of the basic image quality parameters recommended by TG-142 for the Elekta XVI and iView imaging systems. Consistent imaging and dosimetric properties over the evaluated time frame were noted. This work was funded in part by the Cancer Prevention Research Institute of Texas Pre doctoral fellowship training grant (RP140105) to Dennis N. Stanley M.Sc.« less
Goldstein, Ayelet; Shahar, Yuval; Orenbuch, Efrat; Cohen, Matan J
2017-10-01
To examine the feasibility of the automated creation of meaningful free-text summaries of longitudinal clinical records, using a new general methodology that we had recently developed; and to assess the potential benefits to the clinical decision-making process of using such a method to generate draft letters that can be further manually enhanced by clinicians. We had previously developed a system, CliniText (CTXT), for automated summarization in free text of longitudinal medical records, using a clinical knowledge base. In the current study, we created an Intensive Care Unit (ICU) clinical knowledge base, assisted by two ICU clinical experts in an academic tertiary hospital. The CTXT system generated free-text summary letters from the data of 31 different patients, which were compared to the respective original physician-composed discharge letters. The main evaluation measures were (1) relative completeness, quantifying the data items missed by one of the letters but included by the other, and their importance; (2) quality parameters, such as readability; (3) functional performance, assessed by the time needed, by three clinicians reading each of the summaries, to answer five key questions, based on the discharge letter (e.g., "What are the patient's current respiratory requirements?"), and by the correctness of the clinicians' answers. Completeness: In 13/31 (42%) of the letters the number of important items missed in the CTXT-generated letter was actually less than or equal to the number of important items missed by the MD-composed letter. In each of the MD-composed letters, at least two important items that were mentioned by the CTXT system were missed (a mean of 7.2±5.74). In addition, the standard deviation in the number of missed items in the MD letters (STD=15.4) was much higher than the standard deviation in the CTXT-generated letters (STD=5.3). Quality: The MD-composed letters obtained a significantly better grade in three out of four measured parameters. However, the standard variation in the quality of the MD-composed letters was much greater than the standard variation in the quality of the CTXT-generated letters (STD=6.25 vs. STD=2.57, respectively). Functional evaluation: The clinicians answered the five questions on average 40% faster (p<0.001) when using the CTXT-generated letters than when using the MD-composed letters. In four out of the five questions the clinicians' correctness was equal to or significantly better (p<0.005) when using the CTXT-generated letters than when using the MD-composed letters. An automatic knowledge-based summarization system, such as the CTXT system, has the capability to model complex clinical domains, such as the ICU, and to support interpretation and summarization tasks such as the creation of a discharge summary letter. Based on the results, we suggest that the use of such systems could potentially enhance the standardization of the letters, significantly increase their completeness, and reduce the time to write the discharge summary. The results also suggest that using the resultant structured letters might reduce the decision time, and enhance the decision quality, of decisions made by other clinicians. Copyright © 2017 Elsevier B.V. All rights reserved.
Inter-technique validation of tropospheric slant total delays
NASA Astrophysics Data System (ADS)
Kačmařík, Michal; Douša, Jan; Dick, Galina; Zus, Florian; Brenot, Hugues; Möller, Gregor; Pottiaux, Eric; Kapłon, Jan; Hordyniec, Paweł; Václavovic, Pavel; Morel, Laurent
2017-06-01
An extensive validation of line-of-sight tropospheric slant total delays (STD) from Global Navigation Satellite Systems (GNSS), ray tracing in numerical weather prediction model (NWM) fields and microwave water vapour radiometer (WVR) is presented. Ten GNSS reference stations, including collocated sites, and almost 2 months of data from 2013, including severe weather events were used for comparison. Seven institutions delivered their STDs based on GNSS observations processed using 5 software programs and 11 strategies enabling to compare rather different solutions and to assess the impact of several aspects of the processing strategy. STDs from NWM ray tracing came from three institutions using three different NWMs and ray-tracing software. Inter-techniques evaluations demonstrated a good mutual agreement of various GNSS STD solutions compared to NWM and WVR STDs. The mean bias among GNSS solutions not considering post-fit residuals in STDs was -0.6 mm for STDs scaled in the zenith direction and the mean standard deviation was 3.7 mm. Standard deviations of comparisons between GNSS and NWM ray-tracing solutions were typically 10 mm ± 2 mm (scaled in the zenith direction), depending on the NWM model and the GNSS station. Comparing GNSS versus WVR STDs reached standard deviations of 12 mm ± 2 mm also scaled in the zenith direction. Impacts of raw GNSS post-fit residuals and cleaned residuals on optimal reconstructing of GNSS STDs were evaluated at inter-technique comparison and for GNSS at collocated sites. The use of raw post-fit residuals is not generally recommended as they might contain strong systematic effects, as demonstrated in the case of station LDB0. Simplified STDs reconstructed only from estimated GNSS tropospheric parameters, i.e. without applying post-fit residuals, performed the best in all the comparisons; however, it obviously missed part of tropospheric signals due to non-linear temporal and spatial variations in the troposphere. Although the post-fit residuals cleaned of visible systematic errors generally showed a slightly worse performance, they contained significant tropospheric signal on top of the simplified model. They are thus recommended for the reconstruction of STDs, particularly during high variability in the troposphere. Cleaned residuals also showed a stable performance during ordinary days while containing promising information about the troposphere at low-elevation angles.
Evaluation of Postural Control in Patients with Glaucoma Using a Virtual Reality Environment.
Diniz-Filho, Alberto; Boer, Erwin R; Gracitelli, Carolina P B; Abe, Ricardo Y; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A
2015-06-01
To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in patients with glaucoma. Cross-sectional study. The study involved 42 patients with glaucoma with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Torque moments around the center of foot pressure on the force platform were measured, and the standard deviations of the torque moments (STD) were calculated as a measurement of postural stability and reported in Newton meters (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Patients with glaucoma had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) and rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared with those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with a history of falls in patients with glaucoma (incidence rate ratio, 1.85; 95% confidence interval, 1.30-2.63; P = 0.001). The study presented and validated a novel paradigm for evaluation of balance control in patients with glaucoma on the basis of the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with a history of falls and may help to provide a better understanding of balance control in patients with glaucoma. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Evaluation of Postural Control in Glaucoma Patients Using a Virtual 1 Reality Environment
Diniz-Filho, Alberto; Boer, Erwin R.; Gracitelli, Carolina P. B.; Abe, Ricardo Y.; van Driel, Nienke; Yang, Zhiyong; Medeiros, Felipe A.
2015-01-01
Purpose To evaluate postural control using a dynamic virtual reality environment and the relationship between postural metrics and history of falls in glaucoma patients. Design Cross-sectional study. Participants The study involved 42 glaucoma patients with repeatable visual field defects on standard automated perimetry (SAP) and 38 control healthy subjects. Methods Patients underwent evaluation of postural stability by a force platform during presentation of static and dynamic visual stimuli on stereoscopic head-mounted goggles. The dynamic visual stimuli presented rotational and translational ecologically valid peripheral background perturbations. Postural stability was also tested in a completely dark field to assess somatosensory and vestibular contributions to postural control. History of falls was evaluated by a standard questionnaire. Main Outcome Measures Torque moments around the center of foot pressure on the force platform were measured and the standard deviations (STD) of these torque moments were calculated as a measurement of postural stability and reported in Newton meter (Nm). The association with history of falls was investigated using Poisson regression models. Age, gender, body mass index, severity of visual field defect, best-corrected visual acuity, and STD on dark field condition were included as confounding factors. Results Glaucoma patients had larger overall STD than controls during both translational (5.12 ± 2.39 Nm vs. 3.85 ± 1.82 Nm, respectively; P = 0.005) as well as rotational stimuli (5.60 ± 3.82 Nm vs. 3.93 ± 2.07 Nm, respectively; P = 0.022). Postural metrics obtained during dynamic visual stimuli performed better in explaining history of falls compared to those obtained in static and dark field condition. In the multivariable model, STD values in the mediolateral direction during translational stimulus were significantly associated with history of falls in glaucoma patients (incidence-rate ratio = 1.85; 95% CI: 1.30 – 2.63; P = 0.001). Conclusions The study presented and validated a novel paradigm for evaluation of balance control in glaucoma patients based on the assessment of postural reactivity to dynamic visual stimuli using a virtual reality environment. The newly developed metrics were associated with history of falls and may help to provide a better understanding of balance control in glaucoma patients. PMID:25892017
Program Helps Standardize Documentation Of Software
NASA Technical Reports Server (NTRS)
Howe, G.
1994-01-01
Intelligent Documentation Management System, IDMS, computer program developed to assist project managers in implementing information system documentation standard known as NASA-STD-2100-91, NASA STD, COS-10300, of NASA's Software Management and Assurance Program. Standard consists of data-item descriptions or templates, each of which governs particular component of software documentation. IDMS helps program manager in tailoring documentation standard to project. Written in C language.
46 CFR 58.50-10 - Diesel fuel tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... (USSG 18) 0.107 (USSG 12). Steel or iron 4 0.0747 (MfgStd 14) 0.1046 (MfgStd 12) 0.179 (MfgStd 7). 1 Gauges used are U.S. standard “USSG” for aluminum and nickel-copper and “MfgStd” for steel or iron. 2...
46 CFR 58.50-10 - Diesel fuel tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... (USSG 18) 0.107 (USSG 12). Steel or iron 4 0.0747 (MfgStd 14) 0.1046 (MfgStd 12) 0.179 (MfgStd 7). 1 Gauges used are U.S. standard “USSG” for aluminum and nickel-copper and “MfgStd” for steel or iron. 2...
The History of a Decision: A Standard Vibration Test Method for Qualification
Rizzo, Davinia; Blackburn, Mark
2017-01-01
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
The History of a Decision: A Standard Vibration Test Method for Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Davinia; Blackburn, Mark
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
Design and Performance Evaluation on Ultra-Wideband Time-Of-Arrival 3D Tracking System
NASA Technical Reports Server (NTRS)
Ni, Jianjun; Arndt, Dickey; Ngo, Phong; Dusl, John
2012-01-01
A three-dimensional (3D) Ultra-Wideband (UWB) Time--of-Arrival (TOA) tracking system has been studied at NASA Johnson Space Center (JSC) to provide the tracking capability inside the International Space Station (ISS) modules for various applications. One of applications is to locate and report the location where crew experienced possible high level of carbon-dioxide and felt upset. In order to accurately locate those places in a multipath intensive environment like ISS modules, it requires a robust real-time location system (RTLS) which can provide the required accuracy and update rate. A 3D UWB TOA tracking system with two-way ranging has been proposed and studied. The designed system will be tested in the Wireless Habitat Testbed which simulates the ISS module environment. In this presentation, we discuss the 3D TOA tracking algorithm and the performance evaluation based on different tracking baseline configurations. The simulation results show that two configurations of the tracking baseline are feasible. With 100 picoseconds standard deviation (STD) of TOA estimates, the average tracking error 0.2392 feet (about 7 centimeters) can be achieved for configuration Twisted Rectangle while the average tracking error 0.9183 feet (about 28 centimeters) can be achieved for configuration Slightly-Twisted Top Rectangle . The tracking accuracy can be further improved with the improvement of the STD of TOA estimates. With 10 picoseconds STD of TOA estimates, the average tracking error 0.0239 feet (less than 1 centimeter) can be achieved for configuration "Twisted Rectangle".
Tissues viability and blood flow sensing based on a new nanophotonics method
NASA Astrophysics Data System (ADS)
Yariv, Inbar; Haddad, Menashe; Duadi, Hamootal; Motiei, Menachem; Fixler, Dror
2018-02-01
Extracting optical parameters of turbid medium (e.g. tissue) by light reflectance signals is of great interest and has many applications in the medical world, life science, material analysis and biomedical optics. The reemitted light from an irradiated tissue is affected by the light's interaction with the tissue components and contains the information about the tissue structure and physiological state. In this research we present a novel noninvasive nanophotonics technique, i.e., iterative multi-plane optical property extraction (IMOPE) based on reflectance measurements. The reflectance based IMOPE was applied for tissue viability examination, detection of gold nanorods (GNRs) within the blood circulation as well as blood flow detection using the GNRs presence within the blood vessels. The basics of the IMOPE combine a simple experimental setup for recording light intensity images with an iterative Gerchberg-Saxton (G-S) algorithm for reconstructing the reflected light phase and computing its standard deviation (STD). Changes in tissue composition affect its optical properties which results in changes in the light phase that can be measured by its STD. This work presents reflectance based IMOPE tissue viability examination, producing a decrease in the computed STD for older tissues, as well as investigating their organic material absorption capability. Finally, differentiation of the femoral vein from adjacent tissues using GNRs and the detection of their presence within blood circulation and tissues are also presented with high sensitivity (better than computed tomography) to low quantities of GNRs (<3 mg).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
... Laboratory Accreditation for External Dosimetry AGENCY: Office of Health, Safety and Security, Department of... Department) is issuing Technical Standard DOE-STD-1095-2011, Department of Energy Laboratory Accreditation... part, to determine whether to accredit dosimetry programs in accordance with the DOE Laboratory...
NASA-STD 3001 and the Human Integration Design Handbook (HIDH): Evolution of NASA-STD-3000
NASA Technical Reports Server (NTRS)
Pickett, Lynn; Connolly, Janis; Arch, M.; Tillman, Barry; Russo, Dane
2007-01-01
The Habitability & Environmental Factors and Space Medicine Divisions have developed the Space Flight Human System Standard (SFHSS) (NASA-STD-3001) to replace NASA-STD-3000 as a new NASA standard for all human spaceflight programs. The SFHSS is composed of 2 volumes. Volume 1, Crew Health, contains medical levels of care, permissible exposure limits, and fitness for duty criteria, and permissible outcome limits as a means of defining successful operating criteria for the human system. Volume 2, Habitability and Environmental Health, contains environmental, habitability and human factors standards. Development of the Human Integration Design Handbook (HIDH), a companion to the standard, is currently under construction and entails the update and revision of NASA-STD-3000 data. This new handbook will, in the fashion of NASA STD-3000, assist engineers and designers in appropriately applying habitability, environmental and human factors principles to spacecraft design. Organized in a chapter-module-element structure, the HIDH will provide the guidance for the development of requirements, design considerations, lessons learned, example solutions, background research, and assist in the identification of gaps and research needs in the disciplines. Subject matter experts have been and continue to be solicited to participate in the update of the chapters. The purpose is to build the HIDH with the best and latest data, and provide a broad representation from experts in industry, academia, the military and the space program. The handbook and the two standards volumes work together in a unique way to achieve the required level of human-system interface. All new NASA programs will be required to meet Volumes 1 and 2. Volume 2 presents human interface goals in broad, non-verifiable standards. Volume 2 also requires that each new development program prepare a set of program-specific human factors requirements. These program-specific human and environmental factors requirements must be verifiable and tailored to assure the new system meets the Volume 2 standards. Programs will use the HIDH to write their verifiable program-specific requirements.
Taron, Jana; Martirosian, Petros; Erb, Michael; Kuestner, Thomas; Schwenzer, Nina F; Schmidt, Holger; Honndorf, Valerie S; Weiβ, Jakob; Notohamiprodjo, Mike; Nikolaou, Konstantin; Schraml, Christina
2016-10-01
To systematically evaluate image characteristics of simultaneous-multislice (SMS)-accelerated diffusion-weighted imaging (DWI) of the liver using different breathing schemes in comparison to standard sequences. DWI of the liver was performed in 10 healthy volunteers and 12 patients at 1.5T using an SMS-accelerated echo planar imaging sequence performed with respiratory-triggering and free breathing (SMS-RT, SMS-FB). Standard DWI sequences served as reference (STD-RT, STD-FB). Reduction of scan time by SMS-acceleration was measured. Image characteristics of SMS-DWI and STD-DWI with both breathing schemes were analyzed quantitatively (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR]) and qualitatively (5-point Likert scale, 5 = excellent). Qualitative and quantitative parameters were compared using Friedman test and Dunn-Bonferroni post-hoc method with P-values < 0.05 considered statistically significant. SMS-DWI provided diagnostic image quality in volunteers and patients both with RT and FB with a reduction of scan time of 70% (0:56 vs. 3:20 min in FB). Overall image quality did not significantly differ between FB and RT acquisition in both STD and SMS sequences (median STD-RT 5.0, STD-FB 4.5, SMS-RT: 4.75; SMS-FB: 4.5; P = 0.294). SNR in the right hepatic lobe was comparable between the four tested sequences. ADC values were significantly lower in SMS-DWI compared to STD-DWI irrespective of the breathing scheme (1.2 ± 0.2 × 10(-3) mm(2) /s vs. 1.0 ± 0.2 × 10(-3) mm(2) /s; P < 0.001). SMS-acceleration provides considerable scan time reduction for hepatic DWI with equivalent image quality compared to the STD technique both using RT and FB. Discrepancies in ADC between STD-DWI and SMS-DWI need to be considered when transferring the SMS technique to clinical routine reading. J. MAGN. RESON. IMAGING 2016;44:865-879. © 2016 International Society for Magnetic Resonance in Medicine.
Observations of sexually transmitted disease consultations in India.
Mertens, T E; Smith, G D; Kantharaj, K; Mugrditchian, D; Radhakrishnan, K M
1998-03-01
To assess the quality of sexually transmitted disease (STD) case management provided in public and private health facilities in selected areas of Madras, Tamil Nadu, India, in order to make recommendations for improving the quality of care and promote the syndromic approach to STD treatment. Structured observations of consultations for STDs in health care facilities. Scoring of the observations according to standards for history taking, examination, treatment and provision of basic health promotion advice allows evaluation of STD case management. With STD treatment adequacy scored against Indian national guidelines (which recommend aetiologic treatment), history taking, examination and treatment were satisfactory in 76 out of 108 (70%) of observed consultations. However, if STD treatment adequacy is scored with respect to the syndrome approach towards selected STD (male urethritis and non herpetic genital ulcer for both sexes), only 8 out of 81 (10%) of the patients were satisfactory managed. During 32 out of 108 (30%) of the consultations, advice on the use of condoms in order to prevent STD or HIV/AIDS was given. Instructions regarding how to use condoms were offered to seven (6%) patients and condoms were only provided to one patient (1%). Patients were urged to refer their partner(s) for treatment during 29 (27%) of consultations. A criterion of adequate use of the STD consultation for health promotion, requiring both promotion of condoms and encouragement to refer partner(s) for treatment, was met during 13 (12%) of consultations. Monitoring and improving the standards of care at facilities at which STDs are treated have become key roles of STD/HIV/AIDS programmes. The present report suggests that in Madras the activities of medical practitioners who treat STD patients are far from ideal at present. Improvements would involve simplifying existing treatment guidelines by promoting the syndromic approach to STD management, continuing education programmes for health care providers in the public and private sectors and repeat assessments and feedback of the quality of STD care.
NASA-STD-4005 and NASA-HDBK-4006, LEO Spacecraft Solar Array Charging Design Standard
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.
2007-01-01
Two new NASA Standards are now official. They are the NASA LEO Spacecraft Charging Design Standard (NASA-STD-4005) and the NASA LEO Spacecraft Charging Design Handbook (NASA-HDBK-4006). They give the background and techniques for controlling solar array-induced charging and arcing in LEO. In this paper, a brief overview of the new standards is given, along with where they can be obtained and who should be using them.
NASA Space Flight Human System Standards
NASA Technical Reports Server (NTRS)
Tillman, Barry; Pickett, Lynn; Russo, Dane; Stroud, Ken; Connolly, Jan; Foley, Tico
2007-01-01
NASA has begun a new approach to human factors design standards. For years NASA-STD-3000, Manned Systems Integration Standards, has been a source of human factors design guidance for space systems. In order to better meet the needs of the system developers, NASA is revising its human factors standards system. NASA-STD-3000 will be replaced by two documents: set of broad human systems specifications (including both human factors and medical topics) and a human factors design handbook
Military standards and SCATHA program update of MIL-STD-1541
NASA Technical Reports Server (NTRS)
Frankos, D. T.
1980-01-01
The elctromagnetic compatability requirements for space systems, 15 October 1973, to be met by industry contractors for spacecraft launch vehicles and other special space systems, are considered. Deficiencies in the existing standard with respect to spacecraft charge and discharge phenomena, the technical ramifications for generating a new standard, and the upgrading of MIL-STD-1541 with requirements supplied as a result of the SCATHA program are discussed.
40 CFR 92.305 - Credit generation and use calculation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... megawatt-hrs: Credits for each engine family are calculated as: Emission credits=(Std − FEL) × (UL) × (Production) × (Fp) × (10−3 kW-Mg/MW-g). (2) Where: (i) Std=the applicable locomotive and locomotive engine NOX and/or PM emission standard in grams per kilowatt-hour (exceptions: Std=0.43 g/kW-hr, for Tier 0...
40 CFR 92.305 - Credit generation and use calculation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... megawatt-hrs: Credits for each engine family are calculated as: Emission credits=(Std − FEL) × (UL) × (Production) × (Fp) × (10−3 kW-Mg/MW-g). (2) Where: (i) Std=the applicable locomotive and locomotive engine NOX and/or PM emission standard in grams per kilowatt-hour (exceptions: Std=0.43 g/kW-hr, for Tier 0...
40 CFR 92.305 - Credit generation and use calculation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... megawatt-hrs: Credits for each engine family are calculated as: Emission credits=(Std − FEL) × (UL) × (Production) × (Fp) × (10−3 kW-Mg/MW-g). (2) Where: (i) Std=the applicable locomotive and locomotive engine NOX and/or PM emission standard in grams per kilowatt-hour (exceptions: Std=0.43 g/kW-hr, for Tier 0...
40 CFR 92.305 - Credit generation and use calculation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... megawatt-hrs: Credits for each engine family are calculated as: Emission credits=(Std − FEL) × (UL) × (Production) × (Fp) × (10−3 kW-Mg/MW-g). (2) Where: (i) Std=the applicable locomotive and locomotive engine NOX and/or PM emission standard in grams per kilowatt-hour (exceptions: Std=0.43 g/kW-hr, for Tier 0...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cifter, G; Redler, G; Lee, C
Purpose: Compared to traditional radiotherapy techniques, stereotactic body radiation therapy (SBRT) provides more favorable outcomes during the treatment of certain lung tumors. Despite advancements in image guidance, accurate target localization still remains a challenge. In this work, we expand our knowledge of a novel scatter imaging modality in order to develop a real-time tumor localization method using scattered photons from the patient during treatment. Methods: Images of the QUASAR™ Respiratory Motion Phantom were taken by irradiating it on a Varian TrueBeam accelerator. The scattered radiation was detected using a flat panel-based pinhole camera detection system. Two motion settings were investigated:more » static and dynamic. In the former, the lung tumor was manually shifted between imaging. In the latter, the lung tumor was set to move at a certain frequency and amplitude while the images were acquired continuously for one minute. The accuracy of tumor localization and the irradiation time required to distinguish the lung tumor were studied. Results: The comparison of measured and expected location of the lung tumor during static motion was shown to be under standard deviation (STD) of 0.064 with a mean STD of 0.031cm. The dynamic motion was taken at a rate of 1400 MU/min for one minute and the measured location of the lung tumor was then compared with the QUASAR phantom’s sinusoidal motion pattern and the agreement found to be at an average STD of 0.275cm. The location of the lung tumor was investigated using aggregate images consisting of 1 or 2 frames/image and the change was below STD of 0.30cm. The lung tumor also appeared to be blurrier in images consisting of two frames. Conclusion: Based on our preliminary results real-time image guidance using the scatter imaging modality to localize and track tumors during lung SBRT has the potential to become clinical reality.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraus, J; Thomas, E; Wu, X
2016-06-15
Purpose: Single-isocenter VMAT has been shown able to create high quality plans for complex intracranial multiple metastasis SRS cases. Linacs capable of the technique are typically outfitted with an MLC that consists of a combination of 5 mm and 10 mm leaves (standard) or 2.5 mm and 5 mm leaves (high-definition). In this study, we test the hypothesis that thinner collimator leaves are associated with improved plan quality. Methods: Ten multiple metastasis cases were identified and planned for VMAT SRS using a 10 MV flattening filter free beam. Plans were created for a standard (std) and a high-definition (HD) MLC.more » Published values for leaf transmission factor and dosimetric leaf gap were utilized. All other parameters were invariant. Conformity (plan and individual target), moderate isodose spill (V50%), and low isodose spill (mean brain dose) were selected for analysis. Results: Compared to standard MLC, HD-MLC improved overall plan conformity (median: Paddick CI-HD = 0.83, Paddick CI-std = 0.79; p = 0.004 and median: RTOG CI-HD =1.18, RTOG CI-std =1.24; p = 0.01 ), improved individual lesion conformity (median: Paddick CI-HD,i =0.77, Paddick CI-std,i =0.72; p < 0.001 and median: RTOG CI-HD,i = 1.28, RTOG CI-std,i =1.35; p < 0.001), improved moderate isodose spill (median: V50%-HD = 37.0 cc, V50%-std = 45.7 cc; p = 0.002), and improved low dose spill (median: dmean-HD = 2.90 Gy, dmean-std = 3.19 Gy; p = 0.002). Conclusion: For the single-isocenter VMAT SRS of multiple metastasis plans examined, use of HD-MLC modestly improved conformity, moderate isodose, and low isodose spill compared to standard MLC. However, in all cases we were able to generate clinically acceptable plans with the standard MLC. More work is need to further quantify the difference in cases with higher numbers of small targets and to better understand any potential clinical significance. This research was supported in part by Varian Medical Systems.« less
Comparison of ITRF2014 station coordinate input time series of DORIS, VLBI and GNSS
NASA Astrophysics Data System (ADS)
Tornatore, Vincenza; Tanır Kayıkçı, Emine; Roggero, Marco
2016-12-01
In this paper station coordinate time series from three space geodesy techniques that have contributed to the realization of the International Terrestrial Reference Frame 2014 (ITRF2014) are compared. In particular the height component time series extracted from official combined intra-technique solutions submitted for ITRF2014 by DORIS, VLBI and GNSS Combination Centers have been investigated. The main goal of this study is to assess the level of agreement among these three space geodetic techniques. A novel analytic method, modeling time series as discrete-time Markov processes, is presented and applied to the compared time series. The analysis method has proven to be particularly suited to obtain quasi-cyclostationary residuals which are an important property to carry out a reliable harmonic analysis. We looked for common signatures among the three techniques. Frequencies and amplitudes of the detected signals have been reported along with their percentage of incidence. Our comparison shows that two of the estimated signals, having one-year and 14 days periods, are common to all the techniques. Different hypotheses on the nature of the signal having a period of 14 days are presented. As a final check we have compared the estimated velocities and their standard deviations (STD) for the sites that co-located the VLBI, GNSS and DORIS stations, obtaining a good agreement among the three techniques both in the horizontal (1.0 mm/yr mean STD) and in the vertical (0.7 mm/yr mean STD) component, although some sites show larger STDs, mainly due to lack of data, different data spans or noisy observations.
Speech adjustments for room acoustics and their effects on vocal effort
Bottalico, Pasquale
2016-01-01
Objectives The aims of the present study are: (1) to analyze the effects of the acoustical environment and the voice style on time dose (Dt_p,) and fundamental frequency (mean fo and standard deviation std_fo), while taking into account the effect of short term vocal fatigue; (2) to predict the self-reported vocal effort from the voice acoustical parameters. Methods Ten male and ten female subjects were recorded while reading a text in normal and loud styles, in three rooms - anechoic, semi-reverberant and reverberant –with and without acrylic glass panels 0.5 m from the mouth, which increased external auditory feedback. Subjects quantified how much effort was required to speak in each condition on a visual analogue scale after each task. Results (Aim1) In the loud style, Dt_p, fo and std_fo increased. The Dt_p was higher in the reverberant room compared to the other two rooms. Both genders tended to increase fo in less reverberant environments, while a more monotonous speech was produced in rooms with greater reverberation. All three voice parameters increased with short-term vocal fatigue. (Aim2) A model of the vocal effort to acoustic vocal parameters is proposed. The SPL (Sound Pressure Level) contributed to 66% of the variance explained by the model, followed by the fundamental frequency (30%) and the modulation in amplitude (4%). Conclusions The results provide insight into how voice acoustical parameters can predict vocal effort. In particular, it increased when SPL and fo increased and when the amplitude voice modulation (std_ΔSPL) decreased. PMID:28029555
Eustachian tube diameter: Is it associated with chronic otitis media development?
Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet
To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA STD-4005: The LEO Spacecraft Charging Design Standard
NASA Technical Reports Server (NTRS)
Ferguson, Dale C.
2006-01-01
Power systems with voltages higher than about 55 volts may charge in Low Earth Orbit (LEO) enough to cause destructive arcing. The NASA STD-4005 LEO Spacecraft Charging Design Standard will help spacecraft designers prevent arcing and other deleterious effects on LEO spacecraft. The Appendices, an Information Handbook based on the popular LEO Spacecraft Charging Design Guidelines by Ferguson and Hillard, serve as a useful explanation and accompaniment to the Standard.
Application tables for MIL-STD-461B
NASA Astrophysics Data System (ADS)
Schulz, R. B.
1982-02-01
The complexity in application of MIL-STD-461B is reduced by use of tables which summarize requirements of the standard. A separate table is provided for a group of limits applicable to each type of test procedure.
NASA Technical Reports Server (NTRS)
Hart, J. F.
1973-01-01
MSFC-STD-486, Threaded Fasteners, Torque Limits For, is a relatively new standard that has not had much user experience. This test was run to provide such experience and verify the values in MSFC-STD-486. This was accomplished by plotting torque-tension curves on aluminum and alloy steel aircraft quality bolts and nuts through 1/2 inch in diameter.
Effect of swimming suit design on the energy demands of swimming.
Starling, R D; Costill, D L; Trappe, T A; Jozsi, A C; Trappe, S W; Goodpaster, B H
1995-07-01
Eight competitive male swimmers completed a standardized 365.8 m (400 yd) freestyle swimming trial at a fixed pace (approximately 90% of maximal effort) while wearing a torso swim suit (TOR) or a standard racing suit (STD). Oxygen uptake (VO2), blood lactate, heart rate (HR), and distance per stroke (DPS) measurements were obtained. In addition, a video-computer system was used to collect velocity data during a prone underwater glide following a maximal leg push-off from the side of the pool while wearing the TOR and STD suits. These data were used to calculate the total distance covered during the glides. VO2 (3.76 +/- 0.16 vs 3.92 +/- 0.18 l.min-1) and lactate (8.08 +/- 0.53 vs, 9.66 +/- 0.66 mM) were significantly (P < 0.05) lower during the TOR trial than the STD trial. HR was not different (P > 0.05) between the TOR (170.1 +/- 5.1 b.min-1) and STD (173.5 +/- 5.7 b.min-1) trials. DPS was significantly greater during the TOR (2.70 +/- 0.066 m.stroke-1) versus STD (2.58 +/- 0.054 m.stroke-1) trial. A significantly greater total distance was covered during the prone glide while wearing the TOR (2.05 +/- 0.067 m) compared to the STD (2.00 +/- 0.080 m) suit. These findings demonstrate that a specially designed torso suit reduces the energy demand of swimming compared to a standard racing suit which may be due to a reduction in body drag.
NASA Space Flight Human-System Standard Human Factors, Habitability, and Environmental Health
NASA Technical Reports Server (NTRS)
Holubec, Keith; Connolly, Janis
2010-01-01
This slide presentation reviews the history, and development of NASA-STD-3001, NASA Space Flight Human-System Standard Human Factors, Habitability, and Environmental Health, and the related Human Integration Design Handbook. Currently being developed from NASA-STD-3000, this project standard currently in review will be available in two volumes, (i.e., Volume 1 -- VCrew Health and Volume 2 -- Human Factors, Habitability, and Environmental Health) and the handbook will be both available as a pdf file and as a interactive website.
Code of Federal Regulations, 2011 CFR
2011-07-01
... schedule in step 1 of this appendix. This schedule will be designated as the standard (std) test schedule...)2/Ns))std Where: Xs = Individual mileages at which the vehicle will be tested. Ns = Total number of.... Refer to table I and determine tp at (Np − 2)prop degrees of freedom and ts at (Ns − 2)std. 6. If (Aprop...
Code of Federal Regulations, 2012 CFR
2012-07-01
... schedule in step 1 of this appendix. This schedule will be designated as the standard (std) test schedule...)2/Ns))std Where: Xs = Individual mileages at which the vehicle will be tested. Ns = Total number of.... Refer to table I and determine tp at (Np − 2)prop degrees of freedom and ts at (Ns − 2)std. 6. If (Aprop...
Code of Federal Regulations, 2010 CFR
2010-07-01
... schedule in step 1 of this appendix. This schedule will be designated as the standard (std) test schedule...)2/Ns))std Where: Xs = Individual mileages at which the vehicle will be tested. Ns = Total number of.... Refer to table I and determine tp at (Np − 2)prop degrees of freedom and ts at (Ns − 2)std. 6. If (Aprop...
Code of Federal Regulations, 2013 CFR
2013-07-01
... schedule in step 1 of this appendix. This schedule will be designated as the standard (std) test schedule...)2/Ns))std Where: Xs = Individual mileages at which the vehicle will be tested. Ns = Total number of.... Refer to table I and determine tp at (Np − 2)prop degrees of freedom and ts at (Ns − 2)std. 6. If (Aprop...
Classification of sodium MRI data of cartilage using machine learning.
Madelin, Guillaume; Poidevin, Frederick; Makrymallis, Antonios; Regatte, Ravinder R
2015-11-01
To assess the possible utility of machine learning for classifying subjects with and subjects without osteoarthritis using sodium magnetic resonance imaging data. Theory: Support vector machine, k-nearest neighbors, naïve Bayes, discriminant analysis, linear regression, logistic regression, neural networks, decision tree, and tree bagging were tested. Sodium magnetic resonance imaging with and without fluid suppression by inversion recovery was acquired on the knee cartilage of 19 controls and 28 osteoarthritis patients. Sodium concentrations were measured in regions of interests in the knee for both acquisitions. Mean (MEAN) and standard deviation (STD) of these concentrations were measured in each regions of interest, and the minimum, maximum, and mean of these two measurements were calculated over all regions of interests for each subject. The resulting 12 variables per subject were used as predictors for classification. Either Min [STD] alone, or in combination with Mean [MEAN] or Min [MEAN], all from fluid suppressed data, were the best predictors with an accuracy >74%, mainly with linear logistic regression and linear support vector machine. Other good classifiers include discriminant analysis, linear regression, and naïve Bayes. Machine learning is a promising technique for classifying osteoarthritis patients and controls from sodium magnetic resonance imaging data. © 2014 Wiley Periodicals, Inc.
A method of reducing background fluctuation in tunable diode laser absorption spectroscopy
NASA Astrophysics Data System (ADS)
Yang, Rendi; Dong, Xiaozhou; Bi, Yunfeng; Lv, Tieliang
2018-03-01
Optical interference fringe is the main factor that leads to background fluctuation in gas concentration detection based on tunable diode laser absorption spectroscopy. The interference fringes are generated by multiple reflections or scatterings upon optical surfaces in optical path and make the background signal present an approximated sinusoidal oscillation. To reduce the fluctuation of the background, a method that combines dual tone modulation (DTM) with vibration reflector (VR) is proposed in this paper. The combination of DTM and VR can make the unwanted periodic interference fringes to be averaged out and the effectiveness of the method in reducing background fluctuation has been verified by simulation and real experiments in this paper. In the detection system based on the proposed method, the standard deviation (STD) value of the background signal is decreased to 0.0924 parts per million (ppm), which is reduced by a factor of 16 compared with that of wavelength modulation spectroscopy. The STD value of 0.0924 ppm corresponds to the absorption of 4 . 328 × 10-6Hz - 1 / 2 (with effective optical path length of 4 m and integral time of 0.1 s). Moreover, the proposed method presents a better stable performance in reducing background fluctuation in long time experiments.
NASA Astrophysics Data System (ADS)
Corucci, Linda; Masini, Andrea; Cococcioni, Marco
2011-01-01
This paper addresses bathymetry estimation from high resolution multispectral satellite images by proposing an accurate supervised method, based on a neuro-fuzzy approach. The method is applied to two Quickbird images of the same area, acquired in different years and meteorological conditions, and is validated using truth data. Performance is studied in different realistic situations of in situ data availability. The method allows to achieve a mean standard deviation of 36.7 cm for estimated water depths in the range [-18, -1] m. When only data collected along a closed path are used as a training set, a mean STD of 45 cm is obtained. The effect of both meteorological conditions and training set size reduction on the overall performance is also investigated.
NASA Astrophysics Data System (ADS)
Sangelantoni, Lorenzo; Russo, Aniello; Gennaretti, Fabio
2018-02-01
Quantile mapping (QM) represents a common post-processing technique used to connect climate simulations to impact studies at different spatial scales. Depending on the simulation-observation spatial scale mismatch, QM can be used for two different applications. The first application uses only the bias correction component, establishing transfer functions between observations and simulations at similar spatial scales. The second application includes a statistical downscaling component when point-scale observations are considered. However, knowledge of alterations to climate change signal (CCS) resulting from these two applications is limited. This study investigates QM impacts on the original temperature and precipitation CCSs when applied according to a bias correction only (BC-only) and a bias correction plus downscaling (BC + DS) application over reference stations in Central Italy. BC-only application is used to adjust regional climate model (RCM) simulations having the same resolution as the observation grid. QM BC + DS application adjusts the same simulations to point-wise observations. QM applications alter CCS mainly for temperature. BC-only application produces a CCS of the median 1 °C lower than the original ( 4.5 °C). BC + DS application produces CCS closer to the original, except over the summer 95th percentile, where substantial amplification of the original CCS resulted. The impacts of the two applications are connected to the ratio between the observed and the simulated standard deviation (STD) of the calibration period. For the precipitation, original CCS is essentially preserved in both applications. Yet, calibration period STD ratio cannot predict QM impact on the precipitation CCS when simulated STD and mean are similarly misrepresented.
NASA Astrophysics Data System (ADS)
Lederman, Dror; Leader, Joseph K.; Zheng, Bin; Sciurba, Frank C.; Tan, Jun; Gur, David
2011-03-01
Quantitative computed tomography (CT) has been widely used to detect and evaluate the presence (or absence) of emphysema applying the density masks at specific thresholds, e.g., -910 or -950 Hounsfield Unit (HU). However, it has also been observed that subjects with similar density-mask based emphysema scores could have varying lung function, possibly indicating differences of disease severity. To assess this possible discrepancy, we investigated whether density distribution of "viable" lung parenchyma regions with pixel values > -910 HU correlates with lung function. A dataset of 38 subjects, who underwent both pulmonary function testing and CT examinations in a COPD SCCOR study, was assembled. After the lung regions depicted on CT images were automatically segmented by a computerized scheme, we systematically divided the lung parenchyma into different density groups (bins) and computed a number of statistical features (i.e., mean, standard deviation (STD), skewness of the pixel value distributions) in these density bins. We then analyzed the correlations between each feature and lung function. The correlation between diffusion lung capacity (DLCO) and STD of pixel values in the bin of -910HU <= PV < -750HU was -0.43, as compared with a correlation of -0.49 obtained between the post-bronchodilator ratio (FEV1/FVC) measured by the forced expiratory volume in 1 second (FEV1) dividing the forced vital capacity (FVC) and the STD of pixel values in the bin of -1024HU <= PV < -910HU. The results showed an association between the distribution of pixel values in "viable" lung parenchyma and lung function, which indicates that similar to the conventional density mask method, the pixel value distribution features in "viable" lung parenchyma areas may also provide clinically useful information to improve assessments of lung disease severity as measured by lung functional tests.
Heart rate variability (HRV) analysis in radio and TV broadcasting stations workers.
Bortkiewicz, Alicja; Gadzicka, Elżbieta; Szymczak, Wiesław; Zmyślony, Marek
2012-09-01
The aim of the study was to assess the mechanism of cardiovascular impairments in workers exposed to UHF-VHF radio frequency electromagnetic fields (EMF). Heart rate variability (HRV) was analysed using 512 normal heart beats registered at rest. The analysis concerned time-domain (STD R-R) and frequency-domain (VLF, LF, HF) parameters of HRV. Fifty nine workers (group I) with low-level and 12 workers (group II) with high-level exposure were examined. The mean age of the subjects was 47 ± 9 years and 41 ± 14 years, and mean exposure duration 19.1 ± 8.8 years and 13 ± 4 years, in groups I and II, respectively. The groups were divided according to: E(max), E(dose), E(mean) for frequencies UHF, VHF and UHF+VHF: The control group consisted of 42 non-exposed subjects, aged 49 ± 8 years. Statistical analysis comprised one-way analysis of variance, covariance analysis and logistic regression models. In the exposed groups, the heart rate was higher than in the control one. Standard deviation of R-R intervals (STD R-R) was found to be significantly (p = 0.0285) lower in group I (42.5 ± 24.7 ms) compared to the control group (62.9 ± 53.5 ms). The risk of lowered STD R-R was significantly increased (OR = 2.37, p = 0.023) in group II. Both exposed groups presented significantly higher VLF and LF values than the control group (p = 0.005 and p = 0.0025, respectively). The EMF-exposed groups were characterised by the dominance of the sympathetic system (LF/HF 1.3 ± 0.35). The results indicate that exposure to radiofrequency EMF may affect the neurovegetative regulation.
Application of the PJ and NPS evaporation duct models over the South China Sea (SCS) in winter
Yang, Shaobo; Li, Xingfei; Wu, Chao; He, Xin; Zhong, Ying
2017-01-01
The detection of duct height has a significant effect on marine radar or wireless apparatus applications. The paper presents two models to verify the adaptation of evaporation duct models in the SCS in winter. A meteorological gradient instrument used to measure evaporation ducts was fabricated using hydrological and meteorological sensors at different heights. An experiment on the adaptive characteristics of evaporation duct models was carried out over the SCS. The heights of the evaporation ducts were measured by means of log-linear fit, Paulus-Jeske (PJ) and Naval Postgraduate School (NPS) models. The results showed that NPS model offered significant advantages in stability compared with the PJ model. According the collected data computed by the NPS model, the mean deviation (MD) was -1.7 m, and the Standard Deviation (STD) of the MD was 0.8 m compared with the true value. The NPS model may be more suitable for estimating the evaporation duct height in the SCS in winter due to its simpler system characteristics compared with meteorological gradient instruments. PMID:28273113
40 CFR 1039.705 - How do I generate and calculate emission credits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... the following equation: Emission credits (kg) = (Std − FEL) × (Volume) × (AvgPR) × (UL) × (10−3) Where: Std = the emission standard, in grams per kilowatt-hour, that applies under subpart B of this part for...
40 CFR 1039.705 - How do I generate and calculate emission credits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... the following equation: Emission credits (kg) = (Std − FEL) × (Volume) × (AvgPR) × (UL) × (10−3) Where: Std = the emission standard, in grams per kilowatt-hour, that applies under subpart B of this part for...
40 CFR 1039.705 - How do I generate and calculate emission credits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... the following equation: Emission credits (kg) = (Std − FEL) × (Volume) × (AvgPR) × (UL) × (10−3) Where: Std = the emission standard, in grams per kilowatt-hour, that applies under subpart B of this part for...
Garcia, Patricia; Hughes, James; Carcamo, Cesar; Holmes, King K.
2003-01-01
OBJECTIVES: To determine the effectiveness of an intervention for pharmacy workers in improving their recognition and management of sexually transmitted disease (STD) syndromes. METHODS: We randomly selected 14 districts (total population nearly 4 million) from the 24 districts of low socioeconomic status in Lima, Peru. We randomly assigned paired districts to receive training and support for management and prevention of STDs or a control intervention about management of diarrhoea. The STD intervention included interactive luncheon seminars on recognition and management of four STD syndromes (urethral discharge, vaginal discharge, genital ulcers, and pelvic inflammatory disease) and STD/HIV prevention counselling; monthly pharmacy visits by "prevention salespersons" who distributed materials that included "STD/HIV prevention packets" containing information, condoms, and cards given to patients for referral of their sex partners; and workshops for physicians on managing patients with STD syndromes referred from pharmacies. Standardized simulated patients visited pharmacies in intervention and control districts at one, three, and six months after training to assess outcomes. FINDINGS: Standardized simulated patients reported significantly better recognition and management (appropriate antimicrobial regimens provided for discharge syndromes and referral to specially trained physicians for genital ulcers or pelvic inflammatory disease) by pharmacy workers of all four STD syndromes. They also reported significantly more frequent recommendations for use of condoms and treatment of partners at pharmacies in intervention districts than in control districts (by "intention-to-train" analyses, P<0.05 for 47/48 primary outcome comparisons). CONCLUSION: Training was feasible and effectively improved pharmacy workers' practices. PMID:14758407
2011-07-01
Orlando, Florida, September 2009, 09F- SIW -090. [HLA (2000) - 1] - Modeling and Simulation Standard - High Level Architecture (HLA) – Framework and...Simulation Interoperability Workshop, Orlando, FL, USA, September 2009, 09F- SIW -023. [MaK] - www.mak.com [MIL-STD-3011] - MIL-STD-3011...Spring Simulation Interoperability Workshop, Norfolk, VA, USA, March 2007, 07S- SIW -072. [Ross] - Ross, P. and Clark, P. (2005), “Recommended
The Ruggedized STD Bus Microcomputer - A low cost computer suitable for Space Shuttle experiments
NASA Technical Reports Server (NTRS)
Budney, T. J.; Stone, R. W.
1982-01-01
Previous space flight computers have been costly in terms of both hardware and software. The Ruggedized STD Bus Microcomputer is based on the commercial Mostek/Pro-Log STD Bus. Ruggedized PC cards can be based on commercial cards from more than 60 manufacturers, reducing hardware cost and design time. Software costs are minimized by using standard 8-bit microprocessors and by debugging code using commercial versions of the ruggedized flight boards while the flight hardware is being fabricated.
Medical Resource Planning: The Need to Use a Standardized Diagnostic System
1989-12-01
Migraine, all cases 300 Meningo-encephalitis, complicated 301 Meningo-encephalitis, uncomplicated 302 Mumps, all cases 303 Infectious mononucleosis , all...MUMPS 072XX INFECTIOUS MONONUCLEOSIS 075XX TRACHOMA 076XXC 077,%X 13910 ICD9 diagnostic codes ending in XX represent entire range of five digit codes...0.00026 INFECTIOUS MONONUCLEOSIS 456 0.4 0.00357 TRACHOMA 7 0.0 0.00005 STD-SYPHILIS 48 0.0 0.00038 STD-GONOCOCCAL INFECTIONS 363 0.3 0.00284 STD
Code of Federal Regulations, 2013 CFR
2013-07-01
... and CO emissions: Ci = Max [0 or Ci−1 + Xi − (STD + 0.25 × σ)] Where: Ci = The current CumSum...). Xi = The current emission test result for an individual engine. STD = Emission standard (or family...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and CO emissions: Ci = Max [0 or Ci-1 + Xi − (STD + 0.25 × σ)] Where: Ci = The current CumSum...). Xi = The current emission test result for an individual engine. STD = Emission standard. (c) Use...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and CO emissions: Ci = Max [0 or Ci-1 + Xi−(STD + 0.25 × σ)] Where: Ci = The current CumSum statistic...). Xi = The current emission test result for an individual engine. STD = Emission standard (or family...
Code of Federal Regulations, 2014 CFR
2014-07-01
... and CO emissions: Ci = Max [0 or Ci−1 + Xi − (STD + 0.25 × σ)] Where: Ci = The current CumSum...). Xi = The current emission test result for an individual engine. STD = Emission standard (or family...
Wide coverage by volume CT: benefits for cardiac imaging
NASA Astrophysics Data System (ADS)
Sablayrolles, Jean-Louis; Cesmeli, Erdogan; Mintandjian, Laura; Adda, Olivier; Dessalles-Martin, Diane
2005-04-01
With the development of new technologies, computed tomography (CT) is becoming a strong candidate for non-invasive imaging based tool for cardiac disease assessment. One of the challenges of cardiac CT is that a typical scan involves a breath hold period consisting of several heartbeats, about 20 sec with scanners having a longitudinal coverage of 2 cm, and causing the image quality (IQ) to be negatively impacted since beat to beat variation is high likely to occur without any medication, e.g. beta blockers. Because of this and the preference for shorter breath hold durations, a CT scanner with a wide coverage without the compromise in the spatial and temporal resolution of great clinical value. In this study, we aimed at determining the optimum scan duration and the delay relative to beginning of breath hold, to achieve high IQ. We acquired EKG data from 91 consecutive patients (77 M, 14 F; Age: 57 +/- 14) undergoing cardiac CT exams with contrast, performed on LightSpeed 16 and LightSpeed Pro16. As an IQ metric, we adopted the standard deviation of "beat-to-beat variation" (stdBBV) within a virtual scan period. Two radiologists evaluated images by assigning a score of 1 (worst) to 4 best). We validated stdBBV with the radiologist scores, which resulted in a population distribution of 9.5, 9.5, 31, and 50% for the score groups 1, 2, 3, and 4, respectively. Based on the scores, we defined a threshold for stdBBV and identified an optimum combination of virtual scan period and a delay. With the assumption that the relationship between the stdBBV and diagnosable scan IQ holds, our analysis suggested that the success rate can be improved to 100% with scan durations equal or less than 5 sec with a delay of 1 - 2 sec. We confirmed the suggested conclusion with LightSpeed VCT (GE Healthcare Technologies, Waukesha, WI), which has a wide longitudinal coverage, fine isotropic spatial resolution, and high temporal resolution, e.g. 40 mm coverage per rotation of 0.35 sec. Under the light of this study, LightSpeed VCT lends itself to be a clinically tested unique platform to achieve routine cardiac imaging.
van Liere, Geneviève A F S; Hoebe, Christian J P A; Niekamp, Anne-Marie; Koedijk, Femke D H; Dukers-Muijrers, Nicole H T M
2013-04-01
Currently, individuals at risk for sexually transmitted diseases (STDs) are tested extragenitally only if indicated, most often when there is a history of self-reported symptoms or self-reported anal sex. The sensitivity of such selective symptom- and sexual history-based testing for detection of anorectal STD has not been determined. All men having sex with men (MSM) and swingers (heterosexual couples who have sex with other heterosexual couples and their self-identified heterosexual sex partners) attending our STD clinic (consults: n = 1690) from January 2010 until February 2011 were universally tested for urogenital, anorectal, and oropharyngeal Chlamydia trachomatis and Neisseria gonorrhoeae infections (STD). We compared STD prevalence at anorectal site based on universal versus selective testing. Sensitivity of selective symptom- and sexual history-based testing for anorectal STD was 52% for homosexual MSM, 40% for bisexual MSM, 43% for bisexual male swingers, 40% for heterosexual male swingers, and 47% for female swingers. Universal testing of STD clinic clients who were MSM and swingers yielded more than half of all anorectal STD infections and is more sensitive for identifying anorectal STD infections compared with selective testing. Universal testing may be a more effective strategy for interrupting the ongoing transmission in high-risk sexual networks.
Brief Cognitive-Behavioral Treatment for TMD Pain: Long-Term Outcomes and Moderators of Treatment
Litt, Mark D.; Shafer, David M.; Kreutzer, Donald L.
2010-01-01
The purpose of this study was to determine whether a brief (6–8 sessions) cognitive-behavioral treatment for temporomandibular dysfunction-related pain could be efficacious in reducing pain, pain-related interference with lifestyle and depressive symptoms. The patients were 101 men and women with pain in the area of the temporomandibular joint of at least 3 months duration, randomly assigned to either Standard Treatment (STD; n=49) or to Standard Treatment + Cognitive-Behavioral skills training (STD+CBT; n=52). Patients were assessed at posttreatment (6 weeks), 12 weeks, 24 weeks, 36 weeks, and 52 weeks. Linear mixed model analyses of reported pain indicated that both treatments yielded significant decreases in pain, with the STD+CBT condition resulting in steeper decreases in pain over time compared to the STD condition. Somatization, self-efficacy and readiness for treatment emerged as significant moderators of outcome, such that those low in somatization, or higher in self-efficacy or readiness, and treated with STD+CBT reported lower pain over time. Somatization was also a significant moderator of treatment effects on pain-related interference with functioning, with those low on somatization reporting less pain interference over time when treated in the STD+CBT condition. It was concluded that brief treatments can yield significant reductions in pain, life interference and depressive symptoms in TMD sufferers, and that the addition of cognitive-behavioral coping skills will add to efficacy, especially for those low in somatization, or high in readiness or self-efficacy. PMID:20655662
Xu, Fujie; Stoner, Bradley P; Taylor, Stephanie N; Mena, Leandro; Martin, David H; Powell, Suzanne; Markowitz, Lauri E
2013-01-01
At sexually transmitted disease (STD) clinics, advances in testing technology coupled with increasing demands and diminishing resources have promoted the use of testing-only visits (clinic visits with testing for STDs but no full examination) to meet increasing demands for STD services. The aims of the present study were to estimate the prevalence of STD diagnoses that could become "missed diagnoses" if patients would use testing-only visits and to examine patient characteristics associated with these potential missed diagnoses. We conducted a self-administered survey of STD-related symptoms and sexual risk behaviors in patients seeking routine clinical care at 3 STD clinics. Medical charts were abstracted to estimate the prevalence of viral STDs, trichomoniasis, and other diagnoses from standard clinical services that could become missed diagnoses. Of 2582 patients included, the median age was 24 years and 50% were women. In women, overall, 3.2% were diagnosed as having a viral STD; 9.6%, trichomoniasis; and 41.0%, vulvovaginal candidiasis or symptomatic bacterial vaginosis. The prevalence of these potential missed diagnoses varied by patient characteristics, but in women who reported no symptoms, the prevalence of trichomoniasis was still 6.3%. In men, 19.3% received a diagnosis of urethritis but tested negative for both gonorrhea and chlamydia; this prevalence varied from 15.7% in those who reported no symptoms to 32.6% in those who reported malodor. A high proportion of STD clients received diagnoses from standard care visits that would be missed by testing-only visits. When patients, even those asymptomatic, use testing-only visits, missed diagnoses of STDs or related genital tract conditions can be substantial. The potential disadvantages of testing-only visits should be weighed against the advantages of such visits.
New Zealanders working non-standard hours also have greater exposure to other workplace hazards.
Jay, Sarah M; Gander, Philippa H; Eng, Amanda; Cheng, Soo; Douwes, Jeroen; Ellison-Loschmann, Lis; McLean, Dave; Pearce, Neil; 'tMannetje, Andrea
2017-01-01
Exposure to workplace hazards, such as dust, solvents, and fumes, has the potential to adversely affect the health of people. However, the effects of workplace hazards on health may differ when exposure occurs at different times in the circadian cycle, and among people who work longer hours or who do not obtain adequate sleep. The aim of the present study was to document exposures to workplace hazards across a national sample of New Zealanders, comparing people who work a standard 08:00 -17:00 h Monday-to-Friday working week (Std hours) and those who do not (N-Std hours). New Zealanders (n = 10 000) aged 20-64 yrs were randomly selected from the Electoral Roll to take part in a nationwide survey of workplace exposures. Telephone interviews were conducted between 2004 and 2006, using a six-part questionnaire addressing demographics, detailed information on the current or most recent job (including exposures to a range of workplace hazards), sleep, sleepiness, and health status. N-Std hours were categorised on the basis of: being required to start work prior to 07:00 h or finish work after 21:00 h and/or; having a regular on-call commitment (at least once per week) and/or; working rotating shifts and/or; working night shift(s) in the last month. The response rate was 37% (n = 3003), with 22.2% of participants (n = 656) categorised as working N-Std hours. Industry sectors with the highest numbers of participants working N-Std hours were manufacturing, health and community services, and agriculture, fishing, and forestry. Response rate was 37% (n = 3003) with 22.2% (n = 656) categorised as working N-Std hours. Participants working N-Std hours were more likely to be exposed to all identified hazards, including multiple hazards (OR = 2.45, 95% CI = 2.01-3.0) compared to those working Std hours. Participants working N-Std hours were also more likely to report 'never/rarely' getting enough sleep (OR = 1.38, 95% CI = 1.15-1.65), 'never/rarely' waking refreshed (OR = 1.23, 95% CI = 1.04-1.47), and excessive sleepiness (OR = 1.77, 95% CI = 1.29-2.42). New Zealanders working N-Std hours are more likely to be exposed to hazards in the workplace, to be exposed to multiple hazards, and to report inadequate sleep and excessive sleepiness than their colleagues working a standard 08:00-17:00 h Monday-to-Friday working week. More research is needed on the effects of exposure to hazardous substances outside the usual waking day, on the effects of exposure to multiple hazards, and on the combination of hazard exposure and sleep restriction as a result of shift work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jansen, Jacobus F.A.; Department of Radiology, Memorial Sloan-Kettering Cancer Center, New York, New York; Department of Radiology, Maastricht University Medical Center, Maastricht
2012-01-01
Purpose: To correlate proton magnetic resonance spectroscopy ({sup 1}H-MRS), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), and {sup 18}F-labeled fluorodeoxyglucose positron emission tomography ([{sup 18}F]FDG PET) of nodal metastases in patients with head and neck squamous cell carcinoma (HNSCC) for assessment of tumor biology. Additionally, pretreatment multimodality imaging was evaluated for its efficacy in predicting short-term response to treatment. Methods and Materials: Metastatic neck nodes were imaged with {sup 1}H-MRS, DCE-MRI, and [{sup 18}F]FDG PET in 16 patients with newly diagnosed HNSCC, before treatment. Short-term patient radiological response was evaluated at 3 to 4 months. Correlations among {sup 1}H-MRS (choline concentrationmore » relative to water [Cho/W]), DCE-MRI (volume transfer constant [K{sup trans}]; volume fraction of the extravascular extracellular space [v{sub e}]; and redistribution rate constant [k{sub ep}]), and [{sup 18}F]FDG PET (standard uptake value [SUV] and total lesion glycolysis [TLG]) were calculated using nonparametric Spearman rank correlation. To predict short-term responses, logistic regression analysis was performed. Results: A significant positive correlation was found between Cho/W and TLG ({rho} = 0.599; p = 0.031). Cho/W correlated negatively with heterogeneity measures of standard deviation std(v{sub e}) ({rho} = -0.691; p = 0.004) and std(k{sub ep}) ({rho} = -0.704; p = 0.003). Maximum SUV (SUVmax) values correlated strongly with MRI tumor volume ({rho} = 0.643; p = 0.007). Logistic regression indicated that std(K{sup trans}) and SUVmean were significant predictors of short-term response (p < 0.07). Conclusion: Pretreatment multimodality imaging using {sup 1}H-MRS, DCE-MRI, and [{sup 18}F]FDG PET is feasible in HNSCC patients with nodal metastases. Additionally, combined DCE-MRI and [{sup 18}F]FDG PET parameters were predictive of short-term response to treatment.« less
Marvel, Francoise; Rowe, Cynthia L; Colon-Perez, Lissette; DiClemente, Ralph J; Liddle, Howard A
2009-03-01
Drug and juvenile justice involved youths show remarkably high rates of human immunodeficiency virus (HIV)/sexually transmitted disease (STD) risk behaviors. However, existing interventions aimed at reducing adolescent HIV risk behavior have rarely targeted these vulnerable young adolescents, and many approaches focus on individual-level change without attention to family or contextual influences. We describe a new, family-based HIV/ STD prevention model that embeds HIV/STD focused multifamily groups within an adolescent drug abuse and delinquency evidence-based treatment, Multidimensional Family Therapy (MDFT). The approach has been evaluated in a multisite randomized clinical trial with juvenile justice involved youths in the National Institute on Drug Abuse Criminal Justice Drug Abuse Treatment Studies (www.cjdats.org). Preliminary baseline to 6-month outcomes are promising. We describe research on family risk and protective factors for adolescent problem behaviors, and offer a rationale for family-based approaches to reduce HIV/STD risk in this population. We describe the development and implementation of the Multidimensional Family Therapy HIV/STD risk-reduction intervention (MDFT-HIV/ STD) in terms of using multifamily groups and their integration in standard MDFT and also offers a clinical vignette. The potential significance of this empirically based intervention development work is high; MDFT-HIV/STD is the first model to address largely unmet HIV/STD prevention and sexual health needs of substance abusing juvenile offenders within the context of a family-oriented evidence-based intervention.
IMPLEMENTATION OF THE SEISMIC DESIGN CRITERIA OF DOE-STD-1189-2008 APPENDIX A [FULL PAPER
DOE Office of Scientific and Technical Information (OSTI.GOV)
OMBERG SK
2008-05-14
This paper describes the approach taken by two Fluor Hanford projects for implementing of the seismic design criteria from DOE-STD-1189-2008, Appendix A. The existing seismic design criteria and the new seismic design criteria is described, and an assessment of the primary differences provided. The gaps within the new system of seismic design criteria, which necessitate conduct of portions of work to the existing technical standards pending availability of applicable industry standards, is discussed. Two Hanford Site projects currently in the Control Decision (CD)-1 phase of design have developed an approach to implementation of the new criteria. Calculations have been performedmore » to determine the seismic design category for one project, based on information available in early CD-1. The potential effects of DOE-STD-1189-2008, Appendix A seismic design criteria on the process of project alternatives analysis is discussed. Present of this work is expected to benefit others in the DOE Complex that may be implementing DOE-STD-1189-2008.« less
NASA Technical Reports Server (NTRS)
Betts, Juan F.
2001-01-01
The objective of the current study was to assess the repeatability of experiments at NASA Langley's Thermal Acoustic Fatigue Apparatus (TAFA) facility and to use these experiments to validate numerical models. Experiments show that power spectral density (PSD) curves were repeatable except at the resonant frequencies, which tended to vary between 5 Hz to 15 Hz. Results show that the thinner specimen had more variability in the resonant frequency location than the thicker sample, especially for modes higher than the first mode in the frequency range. Root Mean Square (RMS) tended to be more repeatable. The RMS behaved linearly through the SPL range of 135 to 153 dB. Standard Deviations (STDs) of the results tended to be relatively low constant up to about 147 dB. The RMS results were more repeatable than the PDS results. The STD results were less than 10% of the RMS results for both the 0.125 in (0.318 cm) and 0.062 in (0.1588 cm) thick plate. The STD of the PSD results were around 20% to 100% of the mean PSD results for non-resonant and resonant frequencies, respectively, for the 0.125 in (0.318 cm) thicker plate and between 25% to 125% of the mean PSD results, for nonresonant and resonant frequencies, respectively, for the thinner plate.
A NEW DENSITY VARIANCE-MACH NUMBER RELATION FOR SUBSONIC AND SUPERSONIC ISOTHERMAL TURBULENCE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konstandin, L.; Girichidis, P.; Federrath, C.
The probability density function of the gas density in subsonic and supersonic, isothermal, driven turbulence is analyzed using a systematic set of hydrodynamical grid simulations with resolutions of up to 1024{sup 3} cells. We perform a series of numerical experiments with root-mean-square (rms) Mach number M ranging from the nearly incompressible, subsonic (M=0.1) to the highly compressible, supersonic (M=15) regime. We study the influence of two extreme cases for the driving mechanism by applying a purely solenoidal (divergence-free) and a purely compressive (curl-free) forcing field to drive the turbulence. We find that our measurements fit the linear relation between themore » rms Mach number and the standard deviation (std. dev.) of the density distribution in a wide range of Mach numbers, where the proportionality constant depends on the type of forcing. In addition, we propose a new linear relation between the std. dev. of the density distribution {sigma}{sub {rho}} and that of the velocity in compressible modes, i.e., the compressible component of the rms Mach number, M{sub comp}. In this relation the influence of the forcing is significantly reduced, suggesting a linear relation between {sigma}{sub {rho}} and M{sub comp}, independent of the forcing, and ranging from the subsonic to the supersonic regime.« less
Standard Spacecraft Interfaces and IP Network Architectures: Prototyping Activities at the GSFC
NASA Technical Reports Server (NTRS)
Schnurr, Richard; Marquart, Jane; Lin, Michael
2003-01-01
Advancements in fright semiconductor technology have opened the door for IP-based networking in spacecraft architectures. The GSFC believes the same signlJicant cost savings gained using MIL-STD-1553/1773 as a standard low rate interface for spacecraft busses cun be realized for highspeed network interfaces. To that end, GSFC is developing hardware and software to support a seamless, space mission IP network based on Ethernet and MIL-STD-1553. The Ethernet network shall connect all fright computers and communications systems using interface standards defined by the CCSDS Standard Onboard InterFace (SOIF) Panel. This paper shall discuss the prototyping effort underway at GSFC and expected results.
40 CFR 1036.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... throughout the following equations: (1) For vocational engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the emission standard, in g/hp-hr, that applies under subpart B of... tractor engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the...
40 CFR 1036.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... throughout the following equations: (1) For vocational engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the emission standard, in g/hp-hr, that applies under subpart B of... tractor engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the...
40 CFR 1036.705 - Generating and calculating emission credits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... throughout the following equations: (1) For vocational engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the emission standard, in g/hp-hr, that applies under subpart B of... tractor engines: Emission credits (Mg) = (Std−FCL) · (CF) · (Volume) · (UL) · (10−6) Where: Std = the...
Compact, Low-Overhead, MIL-STD-1553B Controller
NASA Technical Reports Server (NTRS)
Katz, Richard; Barto, Rod
2009-01-01
A compact and flexible controller has been developed to provide MIL-STD- 1553B Remote Terminal (RT) communications and supporting and related functions with minimal demand on the resources of the system in which the controller is to be installed. (MIL-STD-1553B is a military standard that encompasses a method of communication and electrical-interface requirements for digital electronic subsystems connected to a data bus. MIL-STD-1553B is commonly used in defense and space applications.) Many other MIL-STD-1553B RT controllers are complicated, and to enable them to function, it is necessary to provide software and to use such ancillary separate hardware devices as microprocessors and dual-port memories. The present controller functions without need for software and any ancillary hardware. In addition, it contains a flexible system interface and extensive support hardware while including on-chip error-checking and diagnostic support circuitry. This controller is implemented within part of a modern field-programmable gate array.
2010-02-01
concentrations were calculated from the following 2 methods: 1. Using peak area ratio of ropivacaine/ bupivacaine of samples versus peak area ratio of...ropivacaine/ bupivacaine of standards (0–3000 ng/mL) using the following formula: RopS (PA of Rop)/(PA of Bup)S /(PA of Rop)/(PA of Bup)STD Bup...1/mL serum used) where Rop ropivacaine, Bup bupivacaine , PA peak area, S sample, and STD standard. 2. Samples of ropivacaine concentrations
Standardization of milk infrared spectra for the retroactive application of calibration models.
Bonfatti, V; Fleming, A; Koeck, A; Miglior, F
2017-03-01
The objective of this study was to standardize the infrared spectra obtained over time and across 2 milk laboratories of Canada to create a uniform historical database and allow (1) the retroactive application of calibration models for prediction of fine milk composition; and (2) the direct use of spectral information for the development of indicators of animal health and efficiency. Spectral variation across laboratories and over time was inspected by principal components analysis (PCA). Shifts in the PCA scores were detected over time, leading to the definition of different subsets of spectra having homogeneous infrared signal. To evaluate the possibility of using common equations on spectra collected by the 2 instruments and over time, we developed a standardization (STD) method. For each subset of data having homogeneous infrared signal, a total of 99 spectra corresponding to the percentiles of the distribution of the absorbance at each wavenumber were created and used to build the STD matrices. Equations predicting contents of saturated fatty acids, short-chain fatty acids, and C18:0 were created and applied on different subsets of spectra, before and after STD. After STD, bias and root mean squared error of prediction decreased by 66% and 32%, respectively. When calibration equations were applied to the historical nonstandardized database of spectra, shifts in the predictions could be observed over time for all investigated traits. Shifts in the distribution of the predictions over time corresponded to the shifts identified by the inspection of the PCA scores. After STD, shifts in the predicted fatty acid contents were greatly reduced. Standardization reduced spectral variability between instruments and over time, allowing the merging of milk spectra data from different instruments into a common database, the retroactive use of calibrations equations, or the direct use of the spectral data without restrictions. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
NASA Handbook for Models and Simulations: An Implementation Guide for NASA-STD-7009
NASA Technical Reports Server (NTRS)
Steele, Martin J.
2013-01-01
The purpose of this Handbook is to provide technical information, clarification, examples, processes, and techniques to help institute good modeling and simulation practices in the National Aeronautics and Space Administration (NASA). As a companion guide to NASA-STD- 7009, Standard for Models and Simulations, this Handbook provides a broader scope of information than may be included in a Standard and promotes good practices in the production, use, and consumption of NASA modeling and simulation products. NASA-STD-7009 specifies what a modeling and simulation activity shall or should do (in the requirements) but does not prescribe how the requirements are to be met, which varies with the specific engineering discipline, or who is responsible for complying with the requirements, which depends on the size and type of project. A guidance document, which is not constrained by the requirements of a Standard, is better suited to address these additional aspects and provide necessary clarification. This Handbook stems from the Space Shuttle Columbia Accident Investigation (2003), which called for Agency-wide improvements in the "development, documentation, and operation of models and simulations"' that subsequently elicited additional guidance from the NASA Office of the Chief Engineer to include "a standard method to assess the credibility of the models and simulations."2 General methods applicable across the broad spectrum of model and simulation (M&S) disciplines were sought to help guide the modeling and simulation processes within NASA and to provide for consistent reporting ofM&S activities and analysis results. From this, the standardized process for the M&S activity was developed. The major contents of this Handbook are the implementation details of the general M&S requirements ofNASA-STD-7009, including explanations, examples, and suggestions for improving the credibility assessment of an M&S-based analysis.
Distributed acoustic sensing: how to make the best out of the Rayleigh-backscattered energy?
NASA Astrophysics Data System (ADS)
Eyal, A.; Gabai, H.; Shpatz, I.
2017-04-01
Coherent fading noise (also known as speckle noise) affects the SNR and sensitivity of Distributed Acoustic Sensing (DAS) systems and makes them random processes of position and time. As in speckle noise, the statistical distribution of DAS SNR is particularly wide and its standard deviation (STD) roughly equals its mean (σSNR/
McClure, Foster D; Lee, Jung K
2012-01-01
The validation process for an analytical method usually employs an interlaboratory study conducted as a balanced completely randomized model involving a specified number of randomly chosen laboratories, each analyzing a specified number of randomly allocated replicates. For such studies, formulas to obtain approximate unbiased estimates of the variance and uncertainty of the sample laboratory-to-laboratory (lab-to-lab) STD (S(L)) have been developed primarily to account for the uncertainty of S(L) when there is a need to develop an uncertainty budget that includes the uncertainty of S(L). For the sake of completeness on this topic, formulas to estimate the variance and uncertainty of the sample lab-to-lab variance (S(L)2) were also developed. In some cases, it was necessary to derive the formulas based on an approximate distribution for S(L)2.
Apostolou, N; Papazoglou, Th; Koutsouris, D
2006-01-01
Image fusion is a process of combining information from multiple sensors. It is a useful tool implemented in the treatment planning programme of Gamma Knife Radiosurgery. In this paper we evaluate advanced image fusion algorithms for Matlab platform and head images. We develop nine level grayscale image fusion methods: average, principal component analysis (PCA), discrete wavelet transform (DWT) and Laplacian, filter - subtract - decimate (FSD), contrast, gradient, morphological pyramid and a shift invariant discrete wavelet transform (SIDWT) method in Matlab platform. We test these methods qualitatively and quantitatively. The quantitative criteria we use are the Root Mean Square Error (RMSE), the Mutual Information (MI), the Standard Deviation (STD), the Entropy (H), the Difference Entropy (DH) and the Cross Entropy (CEN). The qualitative are: natural appearance, brilliance contrast, presence of complementary features and enhancement of common features. Finally we make clinically useful suggestions.
Sexually transmitted diseases in transient British forces in the tropics.
Adams, E J; Strike, P W; Green, A D; Masterton, R G
1994-04-01
To compare the incidence of sexually transmitted diseases (STD) in British troops in the tropics with that in a standard population. Retrospective analysis of STD clinic records over one calendar year. A British Military Hospital in the Tropics serving 1441 resident personnel. All patients attending a STD clinic. 815 cases of STD were recorded during the study period, giving incidence rate of 56,558 per 100,000 population per year. When compared with a matched population from England and Wales, the age standardised relative risk for STD amongst tropical troops was 25.0 (95% confidence interval 24.9 to 25.1). Thirty nine percent of cases reported prostitute contact as a source of their disease. Of patients questioned about condom usage, 70% reported that they did not normally use a condom. British troops spending short periods of time in a tropical environment are significantly more likely to acquire a STD than men in the same age groups in England and Wales. The proportions of cases who reported that they did not use condoms and the number who cited prostitute contact as a source of infection indicate that even greater sexual education of troops on deployment overseas may be required.
49 CFR 194.105 - Worst case discharge.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: Prevention measure Standard Credit(percent) Secondary containment >100% NFPA 30 50 Built/repaired to API standards API STD 620/650/653 10 Overfill protection standards API RP 2350 5 Testing/cathodic protection API...
49 CFR 194.105 - Worst case discharge.
Code of Federal Regulations, 2010 CFR
2010-10-01
...: Prevention measure Standard Credit(percent) Secondary containment > 100% NFPA 30 50 Built/repaired to API standards API STD 620/650/653 10 Overfill protection standards API RP 2350 5 Testing/cathodic protection API...
49 CFR 194.105 - Worst case discharge.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: Prevention measure Standard Credit(percent) Secondary containment >100% NFPA 30 50 Built/repaired to API standards API STD 620/650/653 10 Overfill protection standards API RP 2350 5 Testing/cathodic protection API...
49 CFR 194.105 - Worst case discharge.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: Prevention measure Standard Credit(percent) Secondary containment > 100% NFPA 30 50 Built/repaired to API standards API STD 620/650/653 10 Overfill protection standards API RP 2350 5 Testing/cathodic protection API...
49 CFR 194.105 - Worst case discharge.
Code of Federal Regulations, 2011 CFR
2011-10-01
...: Prevention measure Standard Credit(percent) Secondary containment > 100% NFPA 30 50 Built/repaired to API standards API STD 620/650/653 10 Overfill protection standards API RP 2350 5 Testing/cathodic protection API...
NASA Technical Reports Server (NTRS)
Nelson, Emily S.; Mulugeta, Lealem; Walton, Marlei; Myers, Jerry G.
2014-01-01
In the wake of the Columbia accident, the NASA-STD-7009 [1] credibility assessment was developed as a unifying platform to describe model credibility and the uncertainties in its modeling predictions. This standard is now being adapted by NASAs Human Research Program to cover a wide range of numerical models for human research. When used properly, the standard can improve the process of code development by encouraging the use of best practices. It can also give management more insight in making informed decisions through a better understanding of the models capabilities and limitations.To a newcomer, the abstractions presented in NASA-STD-7009 and the sheer volume of information that must be absorbed can be overwhelming. This talk is aimed at describing the credibility assessment, which is the heart of the standard, in plain terms. It will outline how to develop a credibility assessment under the standard. It will also show how to quickly interpret the graphs and tables that result from the assessment and how to drill down from the top-level view to the foundation of the assessment. Finally, it will highlight some of the resources that are available for further study.
Fecal microbiota transplantation in puppies with canine parvovirus infection
Pereira, Giorgio Q.; Gomes, Lucas A.; Santos, Iago S.; Alfieri, Alice F.; Weese, J. S.
2018-01-01
Background Diarrhea associated with parvovirus infection is common in dogs. Supportive care is the mainstay of treatment, but recovery may be prolonged and mortality rate can be high. Modification of the intestinal bacterial microbiota has been promising in human and veterinary medicine as an adjunctive treatment of various enteric diseases. Objectives To investigate the safety and efficacy of fecal microbiota transplantation (FMT) on the clinical recovery of puppies with acute hemorrhagic diarrhea syndrome. Animals Sixty‐six puppies with parvovirus infection were evaluated at 2 veterinary hospitals. Methods Randomized clinical trial. Puppies were randomly distributed into 2 groups: standard treatment (STD) and standard treatment + FMT (STD + FMT). The STD puppies (n = 33) received only treatment with IV fluids and antimicrobials and the STD + FMT puppies (n = 33) received FMT in addition to standard treatment. For FMT, 10 g of feces from a healthy dog diluted in 10 mL of saline were administered rectally 6‐12 hours post‐admission. Results Among survivors, treatment with FMT was associated with faster resolution of diarrhea (P < .001) and shorter hospitalization time (P = .001; median, 3 days in STD + FMT; median, 6 days in STD) compared to standard treatment. Mortality in STD was 36.4% (12/33) as compared to 21.2% (7/33) in puppies treated with FMT, but there was no statistical difference between groups (P = .174). Polymerase chain reaction indicated that all animals carried canine parvovirus, strain CPV‐2b. Conclusions Fecal microbiota transplantation in parvovirus‐infected puppies was associated with faster resolution of diarrhea. PMID:29460302
Photo-acoustic sensor for detection of oil contamination in compressed air systems.
Lassen, Mikael; Harder, David Baslev; Brusch, Anders; Nielsen, Ole Stender; Heikens, Dita; Persijn, Stefan; Petersen, Jan C
2017-02-06
We demonstrate an online (in-situ) sensor for continuous detection of oil contamination in compressed air systems complying with the ISO-8573 standard. The sensor is based on the photo-acoustic (PA) effect. The online and real-time PA sensor system has the potential to benefit a wide range of users that require high purity compressed air. Among these are hospitals, pharmaceutical industries, electronics manufacturers, and clean room facilities. The sensor was tested for sensitivity, repeatability, robustness to molecular cross-interference, and stability of calibration. Explicit measurements of hexane (C6H14) and decane (C10H22) vapors via excitation of molecular C-H vibrations at approx. 2950 cm-1 (3.38 μm) were conducted with a custom made interband cascade laser (ICL). For the decane measurements a (1 σ) standard deviation (STD) of 0.3 ppb was demonstrated, which corresponds to a normalized noise equivalent absorption (NNEA) coefficient for the prototype PA sensor of 2.8×10-9 W cm-1 Hz1/2.
Can experiential-didactic training improve clinical STD practices?
Dreisbach, Susan; Devine, Sharon; Fitch, John; Anderson, Teri; Lee, Terry; Rietmeijer, Cornelis; Corbett, Kitty K
2011-06-01
High rates of sexually transmitted diseases (STDs) present an ongoing costly public health challenge. One approach to reduce STD transmission is to increase the number of clinicians adopting the Centers for Disease Control and Prevention's STD Treatment Guidelines. This evaluation assesses the effectiveness of a 3-day experiential and didactic training to translate recommendations into practice by increasing clinician knowledge and skills and helping participants anticipate and overcome barriers to implementation. Between 2001 and 2004, 110 direct care clinicians from 10 states participated in one of 27 standardized 3-day interactive trainings offered by the Denver STD/human immunodeficiency virus (HIV) Prevention Training Center. STD/HIV knowledge and clinical skills were measured before, immediately after, and 6 months after training. Practice patterns were assessed before training and after 6 months. Structural barriers to implementation were identified 6 months post-training. Trainees demonstrated significant post-training gains in mean knowledge scores immediately post-training (P < 0.001) and 6 months post-training (P = 0.002). After 6 months, self-reported mean skill levels remained significantly improved compared to precourse (P < 0.05) for each of 27 skills including STD risk assessment, clinical examination, diagnosis, and treatment. Self-reported improvement in practice patterns was significant for 23 of 35 practices (P < 0.05) 6 months post-training. Participants indicated that inadequate time (52.9%), facilities/equipment (51.5%), and staffing (47.1%) interfered with implementation of recommended practices. Experiential-didactic STD/HIV training can modestly improve knowledge, clinical skills, and implementation of STD recommended practices 6 months after training. Further research is needed to identify the impact of improved clinical practices on STD/HIV transmission.
Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A): Developer derating policy
NASA Technical Reports Server (NTRS)
Maciel, Roberto M.
1994-01-01
The derating requirements/factors tabulated in Appendix B of the Goddard Space Flight Center Preferred Parts List (GSFC PPL) and Appendix A of MIL-STD-975 (NASA Standard Electrical, Electronic and Electromechanical (EEE) Parts List) should be used. Where differences occur, the PPL derating factors should have precedence over the derating factors of MIL-STD-975. When a derating factor is not provided in either the PPL or MIL-STD-975, the GSFC EOS Parts Branch Specialist should be consulted. In addition, the Performance Assurance Requirement (PAR) stipulates that all piece parts shall function at or above twice the expected ionizing radiation dose.
NASA Astrophysics Data System (ADS)
Visser, Eric P.; Disselhorst, Jonathan A.; van Lier, Monique G. J. T. B.; Laverman, Peter; de Jong, Gabie M.; Oyen, Wim J. G.; Boerman, Otto C.
2011-02-01
The image reconstruction algorithms provided with the Siemens Inveon small-animal PET scanner are filtered backprojection (FBP), 3-dimensional reprojection (3DRP), ordered subset expectation maximization in 2 or 3 dimensions (OSEM2D/3D) and maximum a posteriori (MAP) reconstruction. This study aimed at optimizing the reconstruction parameter settings with regard to image quality (IQ) as defined by the NEMA NU 4-2008 standards. The NEMA NU 4-2008 image quality phantom was used to determine image noise, expressed as percentage standard deviation in the uniform phantom region (%STD unif), activity recovery coefficients for the FDG-filled rods (RC rod), and spill-over ratios for the non-radioactive water- and air-filled phantom compartments (SOR wat and SOR air). Although not required by NEMA NU 4, we also determined a contrast-to-noise ratio for each rod (CNR rod), expressing the trade-off between activity recovery and image noise. For FBP and 3DRP the cut-off frequency of the applied filters, and for OSEM2D and OSEM3D, the number of iterations was varied. For MAP, the "smoothing parameter" β and the type of uniformity constraint (variance or resolution) were varied. Results of these analyses were demonstrated in images of an FDG-injected rat showing tumours in the liver, and of a mouse injected with an 18F-labeled peptide, showing a small subcutaneous tumour and the cortex structure of the kidneys. Optimum IQ in terms of CNR rod for the small-diameter rods was obtained using MAP with uniform variance and β=0.4. This setting led to RC rod,1 mm=0.21, RC rod,2 mm=0.57, %STD unif=1.38, SOR wat=0.0011, and SOR air=0.00086. However, the highest activity recovery for the smallest rods with still very small %STD unif was obtained using β=0.075, for which these IQ parameters were 0.31, 0.74, 2.67, 0.0041, and 0.0030, respectively. The different settings of reconstruction parameters were clearly reflected in the rat and mouse images as the trade-off between the recovery of small structures (blood vessels, small tumours, kidney cortex structure) and image noise in homogeneous body parts (healthy liver background). Highest IQ for the Inveon PET scanner was obtained using MAP reconstruction with uniform variance. The setting of β depended on the specific imaging goals.
NASA Astrophysics Data System (ADS)
Ji, Y.; Han, H.; Lee, H.
2014-12-01
Analysis of the surface properties of Antarctica is very important to study the change of environment and climate in the polar region. Synthetic aperture radar (SAR) has been widely used to study Antarctic surface properties because it is independent of sun altitude and atmospheric conditions. Interferometric SAR (InSAR) observes surface topography and deformation, by calculating the phase differences between two or more SAR images obtained over same area. InSAR technique can be used for height mapping in stable areas with a few meter accuracy. However, the InSAR-derived height map can have errors if the phase differences due to surface deformation or change of the scattering center by microwave penetration into snow are misinterpreted as the elevation. In this study, we generated the height maps around Terra Nova Bay in East Antarctica from 13 COSMO-SkyMed one-day tandem InSAR pairs obtained from December 2010 to January 2012. By analyzing the height maps averaged over the 13 interferograms and its standard deviation (STD) map, we could classify the surface types into glacier, mountains and basin areas covered with snow. The mountain areas showed very small STD because its surface property is unchanged with time, except for the small STD values caused by the errors from the unwrapping processing, satellite orbit or atmospheric phase distortion. Over the basin areas, however, the STD of the height was much larger than the mountain area due to the variation of scattering center either from the change in surface property such as snowfall and sublimation or by the surface displacement of snow mass that are too slow. A year-long constant motion of such slow-creeping snow body was positively identified by its linear relationship between the misinterpreted elevation and the baseline perpendicular component of InSAR pair. Analysis of time-series coherence maps and amplitude maps have also contributed to clarify the surface properties and its changes due to various environmental factors such as snow fall, wind, sublimation, and the freezing-thawing processes in this Antarctic land surface. Acknowledgement - This research was supported by National Research Foundation of Korea through NRF-2013R1A1A2008062 and NRF-2013M1A3A3A02041853.
A new amperometric nanostructured sensor for the analytical determination of hydrogen peroxide.
Guascito, M R; Filippo, E; Malitesta, C; Manno, D; Serra, A; Turco, A
2008-12-01
A new amperometric, nanostructured sensor for the analytical determination of hydrogen peroxide is proposed. This sensor was constructed by immobilizing silver nanoparticles in a polyvinyl alcohol (PVA) film on a platinum electrode, which was performed by direct drop-casting silver nanoparticles that were capped in a PVA colloidal suspension. UV-vis spectroscopy, X-ray diffraction and transmission electron microscopy were used to give a complete characterization of the nanostructured film. Cyclic voltammetry experiments yielded evidence that silver nanoparticles facilitate hydrogen peroxide reduction, showing excellent catalytic activity. Moreover, the cronoamperometric response of modified sensors was dependent on nanoparticle lifetime. Experiments were performed, using freshly prepared solutions, after 4 and 8 days. Results concerning the quantitative analysis of hydrogen peroxide, in terms of detection limit, linear range, sensitivity and standard deviation (STD), are discussed for each tested sensor type. Utilization of two different linear ranges (40 microM to 6mM and 1.25 microM to 1.0mM) enabled the assessment of concentration intervals having up to three orders of magnitude. Moreover, the electrode made using a 4-day-old solution showed the maximal sensitivity of 128 nA microM(-1)(4090 nA microM(-1)cm(-2)), yielding a limit of detection of 1 microuM and STD of 2.5 microAmM(-1). All of these analytical parameters make the constructed sensors suitable for peroxide determination in aqueous solution.
Multi-model ensemble combinations of the water budget in the East/Japan Sea
NASA Astrophysics Data System (ADS)
HAN, S.; Hirose, N.; Usui, N.; Miyazawa, Y.
2016-02-01
The water balance of East/Japan Sea is determined mainly by inflow and outflow through the Korea/Tsushima, Tsugaru and Soya/La Perouse Straits. However, the volume transports measured at three straits remain quantitatively unbalanced. This study examined the seasonal variation of the volume transport using the multiple linear regression and ridge regression of multi-model ensemble (MME) methods to estimate physically consistent circulation in East/Japan Sea by using four different data assimilation models. The MME outperformed all of the single models by reducing uncertainties, especially the multicollinearity problem with the ridge regression. However, the regression constants turned out to be inconsistent with each other if the MME was applied separately for each strait. The MME for a connected system was thus performed to find common constants for these straits. The estimation of this MME was found to be similar to the MME result of sea level difference (SLD). The estimated mean transport (2.42 Sv) was smaller than the measurement data at the Korea/Tsushima Strait, but the calibrated transport of the Tsugaru Strait (1.63 Sv) was larger than the observed data. The MME results of transport and SLD also suggested that the standard deviation (STD) of the Korea/Tsushima Strait is larger than the STD of the observation, whereas the estimated results were almost identical to that observed for the Tsugaru and Soya/La Perouse Straits. The similarity between MME results enhances the reliability of the present MME estimation.
Multi-model ensemble estimation of volume transport through the straits of the East/Japan Sea
NASA Astrophysics Data System (ADS)
Han, Sooyeon; Hirose, Naoki; Usui, Norihisa; Miyazawa, Yasumasa
2016-01-01
The volume transports measured at the Korea/Tsushima, Tsugaru, and Soya/La Perouse Straits remain quantitatively inconsistent. However, data assimilation models at least provide a self-consistent budget despite subtle differences among the models. This study examined the seasonal variation of the volume transport using the multiple linear regression and ridge regression of multi-model ensemble (MME) methods to estimate more accurately transport at these straits by using four different data assimilation models. The MME outperformed all of the single models by reducing uncertainties, especially the multicollinearity problem with the ridge regression. However, the regression constants turned out to be inconsistent with each other if the MME was applied separately for each strait. The MME for a connected system was thus performed to find common constants for these straits. The estimation of this MME was found to be similar to the MME result of sea level difference (SLD). The estimated mean transport (2.43 Sv) was smaller than the measurement data at the Korea/Tsushima Strait, but the calibrated transport of the Tsugaru Strait (1.63 Sv) was larger than the observed data. The MME results of transport and SLD also suggested that the standard deviation (STD) of the Korea/Tsushima Strait is larger than the STD of the observation, whereas the estimated results were almost identical to that observed for the Tsugaru and Soya/La Perouse Straits. The similarity between MME results enhances the reliability of the present MME estimation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Altundal, Y; Pokhrel, D; Jiang, H
Purpose: To compare image quality parameters and assessing the image stability of three different linear accelerators (linac) for 2D and 3D imaging modalities: planar kV, MV images and cone-beam CT (CBCT). Methods: QCkV1, QC-3 and Cathpan-600 phantoms were utilized to acquire kV, MV and CBCT images respectively on monthly basis per TG142 QA protocol for over 2 years on 21Ex, NovalisTx and TrueBeam linacs. DICOM images were analyzed with the help of QA analysis software: PIPsPro from Standard Imaging. For planar kV and MV images, planar spatial resolution, contrast to noise ratio (CNR) and noise; for CBCT, HU values weremore » collected and analyzed. Results: Two years of monthly QA measurements were analyzed for the planar and CBCT images. Values were normalized to the mean and the standard deviations (STD) are presented. For the kV planar radiographic images the STD of spatial resolution for f30, f40, f50, CNR and noise for 21Ex are 0.006, 0.011, 0.013, 0.046, 0.026; Novalis-Tx are 0.009, 0.016, 0.016, 0.067, 0.053 ; TrueBeam are 0.007, 0.005, 0.009, 0.017, 0.016 respectively. For the MV planar radiographic images, the STD of spatial resolution for f30, f40, f50, CNR and noise for 21Ex are 0.009, 0.010, 0.008, 0.023, 0.023; for Novalix-Tx are 0.012, 0.010, 0.008, 0.029, 0.023 and for TrueBeam are 0.010, 0.010, 0.007, 0.022, 0.022 respectively. For the CBCT images, HU constancies of Air, Polystyrene, Teflon, PMP, LDPE and Delrin for 21Ex are 0.014, 0.070, 0.031, 0.053, 0.076, 0.087; for Novalis Tx are 0.019, 0.047, 0.035, 0.059, 0.077, 0.087 and for TrueBeam are 0.011, 0.044, 0.025, 0.044, 0.056, 0.020 respectively. Conclusion: These Imaging QA results demonstrated that the TrueBeam, performed better in terms of image quality stability for both kV planer and CBCT images as well as EPID MV images, however other two linacs were also satisfied TG142 guidelines.« less
NASA-STD-7009 Guidance Document for Human Health and Performance Models and Simulations
NASA Technical Reports Server (NTRS)
Walton, Marlei; Mulugeta, Lealem; Nelson, Emily S.; Myers, Jerry G.
2014-01-01
Rigorous verification, validation, and credibility (VVC) processes are imperative to ensure that models and simulations (MS) are sufficiently reliable to address issues within their intended scope. The NASA standard for MS, NASA-STD-7009 (7009) [1] was a resultant outcome of the Columbia Accident Investigation Board (CAIB) to ensure MS are developed, applied, and interpreted appropriately for making decisions that may impact crew or mission safety. Because the 7009 focus is engineering systems, a NASA-STD-7009 Guidance Document is being developed to augment the 7009 and provide information, tools, and techniques applicable to the probabilistic and deterministic biological MS more prevalent in human health and performance (HHP) and space biomedical research and operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mount, M E; O'Connell, W J
2005-06-03
Lawrence Livermore National Laboratory (LLNL) uses the LLNL passive-active neutron drum (PAN) shuffler (Canberra Model JCC-92) for accountability measurement of highly enriched uranium (HEU) oxide and HEU in mixed uranium-plutonium (U-Pu) oxide. In June 2002, at the 43rd Annual Meeting of the Institute of Nuclear Material Management, LLNL reported on an extensive effort to calibrate this shuffler, based on standards measurements and extensive simulations, for HEU oxides and mixed U-Pu oxides in thin-walled primary and secondary containers. In August 2002, LLNL began to also use DOE-STD-3013-2000 containers for HEU oxide and mixed U-Pu oxide. These DOE-STD-3013-2000 containers are comprised ofmore » a stainless steel convenience can enclosed in welded stainless steel primary and secondary containers. Compared to the double thin-walled containers, the DOE-STD-3013-2000 containers have substantially thicker walls, and the density of materials in these containers was found to extend over a greater range (1.35 g/cm{sup 3} to 4.62 g/cm{sup 3}) than foreseen for the double thin-walled containers. Further, the DOE-STD-3013-2000 Standard allows for oxides containing at least 30 wt% Pu plus U whereas the calibration algorithms for thin-walled containers were derived for virtually pure HEU or mixed U-Pu oxides. An initial series of Monte Carlo simulations of the PAN shuffler response to given quantities of HEU oxide and mixed U-Pu oxide in DOE-STD-3013-2000 containers was generated and compared with the response predicted by the calibration algorithms for thin-walled containers. Results showed a decrease on the order of 10% in the count rate, and hence a decrease in the calculated U mass for measured unknowns, with some varying trends versus U mass. Therefore a decision was made to develop a calibration algorithm for the PAN shuffler unique to the DOE-STD-3013-2000 container. This paper describes that effort and selected unknown item measurement results.« less
Application of IUS equipment and experience to orbit transfer vehicles of the 90's
NASA Astrophysics Data System (ADS)
Bangsund, E.; Keeney, J.; Cowgill, E.
1985-10-01
This paper relates experiences with the IUS program and the application of that experience to Future Orbit Transfer Vehicles. More specifically it includes the implementation of the U.S. Air Force Space Division high reliability parts standard (SMASO STD 73-2C) and the component/system test standard (MIL-STD-1540A). Test results from the parts and component level testing and the resulting system level test program for fourteen IUS flight vehicles are discussed. The IUS program has had the highest compliance with these standards and thus offers a benchmark of experience for future programs demanding extreme reliability. In summary, application of the stringent parts standard has resulted in fewer failures during testing and the stringent test standard has eliminated design problems in the hardware. Both have been expensive in costs and schedules, and should be applied with flexibility.
Angulo, Jesús; Enríquez-Navas, Pedro M; Nieto, Pedro M
2010-07-12
The direct evaluation of dissociation constants (K(D)) from the variation of saturation transfer difference (STD) NMR spectroscopy values with the receptor-ligand ratio is not feasible due to the complex dependence of STD intensities on the spectral properties of the observed signals. Indirect evaluation, by competition experiments, allows the determination of K(D), as long as a ligand of known affinity is available for the protein under study. Herein, we present a novel protocol based on STD NMR spectroscopy for the direct measurements of receptor-ligand dissociation constants (K(D)) from single-ligand titration experiments. The influence of several experimental factors on STD values has been studied in detail, confirming the marked impact on standard determinations of protein-ligand affinities by STD NMR spectroscopy. These factors, namely, STD saturation time, ligand residence time in the complex, and the intensity of the signal, affect the accumulation of saturation in the free ligand by processes closely related to fast protein-ligand rebinding and longitudinal relaxation of the ligand signals. The proposed method avoids the dependence of the magnitudes of ligand STD signals at a given saturation time on spurious factors by constructing the binding isotherms using the initial growth rates of the STD amplification factors, in a similar way to the use of NOE growing rates to estimate cross relaxation rates for distance evaluations. Herein, it is demonstrated that the effects of these factors are cancelled out by analyzing the protein-ligand association curve using STD values at the limit of zero saturation time, when virtually no ligand rebinding or relaxation takes place. The approach is validated for two well-studied protein-ligand systems: the binding of the saccharides GlcNAc and GlcNAcbeta1,4GlcNAc (chitobiose) to the wheat germ agglutinin (WGA) lectin, and the interaction of the amino acid L-tryptophan to bovine serum albumin (BSA). In all cases, the experimental K(D) measured under different experimental conditions converged to the thermodynamic values. The proposed protocol allows accurate determinations of protein-ligand dissociation constants, extending the applicability of the STD NMR spectroscopy for affinity measurements, which is of particular relevance for those proteins for which a ligand of known affinity is not available.
Standard Engineering Installation Package, Standard Remote Terminals (SRT).
1981-10-30
6L L o 0 100 BOLT // M 0 (NOTE 3) N o @ 12 P o 13 NOTE: USE MiTN SAAD-D-4053 AND 0 14 • STD-SD-00SS DWS. 1I USE 3(4 CONDUIT AND BOX CONN. PUNCH OUT 3/4...TERMINAL STRIP. USE # BOLT TO MOUNT CONNECTOR TO DLII. USE OG STD-SO-007 FOR TERMINAL STRIP TERMINA- TION TO 153 PATCH PANEL. *1 f DUS1 is not or’dered... BOLTED TO FLOOR AS PER DUG 3I ®STu-SD-OO69 PROVIDING THERE IS INO CROSS OVLR WITH POWER AND SIGNAL CABLES. CROSSOVER WILL BE SEPERATED BY 4" MINIMUM
Crew Transportation Technical Management Processes
NASA Technical Reports Server (NTRS)
Mckinnie, John M. (Compiler); Lueders, Kathryn L. (Compiler)
2013-01-01
Under the guidance of processes provided by Crew Transportation Plan (CCT-PLN-1100), this document, with its sister documents, International Space Station (ISS) Crew Transportation and Services Requirements Document (CCT-REQ-1130), Crew Transportation Technical Standards and Design Evaluation Criteria (CCT-STD-1140), Crew Transportation Operations Standards (CCT STD-1150), and ISS to Commercial Orbital Transportation Services Interface Requirements Document (SSP 50808), provides the basis for a National Aeronautics and Space Administration (NASA) certification for services to the ISS for the Commercial Provider. When NASA Crew Transportation System (CTS) certification is achieved for ISS transportation, the Commercial Provider will be eligible to provide services to and from the ISS during the services phase.
DOE standard: The Department of Energy Laboratory Accreditation Program for radiobioassay
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-01
This technical standard describes the US Department of Energy Laboratory Accreditation Program (DOELAP) for Radiobioassay, for use by the US Department of Energy (DOE) and DOE Contractor radiobioassay programs. This standard is intended to be used in conjunction with the general administrative technical standard that describes the overall DOELAP accreditation process--DOE-STD-1111-98, Department of Energy Laboratory Accreditation Program Administration. This technical standard pertains to radiobioassay service laboratories that provide either direct or indirect (in vivo or in vitro) radiobioassay measurements in support of internal dosimetry programs at DOE facilities or for DOE and DOE contractors. Similar technical standards have been developedmore » for other DOELAP dosimetry programs. This program consists of providing an accreditation to DOE radiobioassay programs based on successful completion of a performance-testing process and an on-site evaluation by technical experts. This standard describes the technical requirements and processes specific to the DOELAP Radiobioassay Accreditation Program as required by 10 CFR 835 and as specified generically in DOE-STD-1111-98.« less
Partner notification of sexually transmitted diseases: practices and preferences.
Gursahaney, Priya R; Jeong, Kwonho; Dixon, Bruce W; Wiesenfeld, Harold C
2011-09-01
Timely notification and treatment of sex partners exposed to a sexually transmitted disease (STD) is essential to reduce reinfection and transmission. Our objectives were to determine factors associated with patient-initiated notification of sex partners and preferences regarding standard partner referral versus expedited partner therapy (EPT). Participants diagnosed with gonorrhea, chlamydia, trichomoniasis, or nongonococcal urethritis within the previous year were administered a baseline survey asking about demographics, sexual history, and partner treatment preferences (standard partner referral vs. EPT). They identified up to 4 sex partners within the past 2 months, and answered questions on relationship characteristics, quality, and notification self-efficacy. At follow-up, participants with a current STD were asked whether they notified their partners. Generalized estimating equations were used to evaluate the associations between predictor variables and partner notification. Of the 201 subjects enrolled, 157 had a current STD diagnosis, and 289 sex partners were identified. The rate of successful partner notification was 77.3% (157/203 sex partners). Partner notification was increased if the subject had a long-term relationship with a sex partner (odds ratio: 3.07; 95% confidence interval: 1.43, 6.58), considered the partner to be a main partner (odds ratio: 2.53; 95% confidence interval: 1.43, 6.58), or had increased notification self-efficacy. Overall, participants did not prefer EPT over standard referral; however, females, those with higher education levels, and those with a prior STD preferred EPT. Patient-initiated partner referral is more successful in patients with increased self-efficacy who have stronger interpersonal relationships with their sex partners.
Kocic, G; Pavlovic, R; Nikolic, G; Stojanovic, D; Jevtovic, T; Sokolovic, D; Cencic, A; Stojanovic, S; Jelic, M; Zivanovic, S
2012-08-01
Hyperuricaemia and gout are closely related, but hyperuricaemia is an independent risk factor for endothelial damage, autoinflammation and haemodynamic abnormalities. Milk, generally known as a 'purine-free diet', is an essential protein source for patients suffering from hyperuricaemia and gout. As milk still contains different purine ribonucleotides, the new product, depurinized milk, almost free of purine nucleotides and uric acid, was produced. The potential effect of depurinized milk diet on serum uric acid (SUA) level, lipid parameters and blood haematological parameters was explored in rats after 72 h and 15 days, in relation to standard laboratory chow or the untreated milk diet. The beneficial effect on SUA was achieved when depurinized milk draught was given instead of standard chow for 72 h [28.39 ± 4.76 μm; p < 0.001 vs. standard diet (STD) 47.6 ± 6.12, vs. untreated milk diet 31.55 ± 8.50; p < 0.05] or as a supplement for STD for 15 days experiment (35.38 ± 6.40 μm; p < 0.05 vs. STD only 48.05 ± 4.32; vs. untreated milk + STD 46.02 ± 9.48). Depurinized milk diet significantly decreased the low density lipoproteins/high density lipoproteins (LDL/HDL) ratio (p < 0.001), triglycerides (p < 0.05) and leucocyte count (p < 0.001), while both milk draughts enhanced haemoglobin concentration (p < 0.01). In conclusion, considering the detrimental effect of persisting hyperuricaemia, the depurinized milk draught may meet the demand of healthy dairy product for population under hyperuricaemic risk. © 2011 Blackwell Verlag GmbH.
Daley, Marilyn C.; Neuman, Matthew J.; Blaakman, Aaron P.; McKay, James R.
2016-01-01
Purpose To investigate whether telephone-based continuing care (TEL) is a promising alternative to traditional face-to-face counseling for clients in treatment for substance abuse. Methods Patients with alcohol and/or cocaine dependence who had completed a 4-week intensive outpatient program were randomly assigned through urn randomization into one of three 12-week interventions: standard continuing care (STD), in-person relapse prevention (RP), or telephone-based continuing care (TEL). This study performed cost, cost-effectiveness, and cost-benefit analyses of TEL and RP compared to STD, using results from the randomized clinical trial with two years of follow up (359 participants). In addition, the study examined the potential moderating effect of baseline patient costs on economic outcomes. Results The study found that TEL was less expensive per client from the societal perspective ($569) than STD ($870) or RP ($1,684). TEL also was also significantly more effective, with an abstinence rate of 57.1% compared to 46.7% for STD (p<0.05). Thus TEL dominated STD, with a highly favorable negative incremental cost-effectiveness ratio (−$1,400 per abstinent year). TEL also proved favorable under a benefit-cost perspective. Conclusions TEL proved to be a cost-effective and cost-beneficial contributor to long-term recovery over two years. Because TEL dominated STD care interventions, wider adoption should be considered. PMID:26718395
Shepard, Donald S; Daley, Marilyn C; Neuman, Matthew J; Blaakman, Aaron P; McKay, James R
2016-02-01
To investigate whether telephone-based continuing care (TEL) is a promising alternative to traditional face-to-face counseling for clients in treatment for substance abuse. Patients with alcohol and/or cocaine dependence who had completed a 4-week intensive outpatient program were randomly assigned through urn randomization into one of three 12-week interventions: standard continuing care (STD), in-person relapse prevention (RP), or telephone-based continuing care (TEL). This study performed cost, cost-effectiveness, and cost-benefit analyses of TEL and RP compared to STD, using results from the randomized clinical trial with two years of follow up (359 participants). In addition, the study examined the potential moderating effect of baseline patient costs on economic outcomes. The study found that TEL was less expensive per client from the societal perspective ($569) than STD ($870) or RP ($1684). TEL also was also significantly more effective, with an abstinence rate of 57.1% compared to 46.7% for STD (p<0.05). Thus TEL dominated STD, with a highly favorable negative incremental cost-effectiveness ratio (-$1400 per abstinent year). TEL also proved favorable under a benefit-cost perspective. TEL proved to be a cost-effective and cost-beneficial contributor to long-term recovery over two years. Because TEL dominated STD care interventions, wider adoption should be considered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Four-Channel PC/104 MIL-STD-1553 Circuit Board
NASA Technical Reports Server (NTRS)
Cox, Gary L.
2004-01-01
The mini bus interface card (miniBIC) is the first four-channel electronic circuit board that conforms to MIL-STD-1553 and to the electrical-footprint portion of PC/104. [MIL-STD-1553 is a military standard that encompasses a method of communication and electrical- interface requirements for digital electronic subsystems connected to a data bus. PC/104 is an industry standard for compact, stackable modules that are fully compatible (in architecture, hardware, and software) with personal-computer data- and power-bus circuitry.] Prior to the development of the miniBIC, only one- and two-channel PC/104 MIL-STD-1553 boards were available. To obtain four channels, it was necessary to include at least two boards in a PC/104 stack. In comparison with such a two-board stack, the miniBIC takes up less space, consumes less power, and is more reliable. In addition, the miniBIC includes 32 digital input/output channels. The miniBIC (see figure) contains four MIL-STD-1553B hybrid integrated circuits (ICs), four transformers, a field-programmable gate array (FPGA), and an Industry Standard Architecture (ISA) interface. Each hybrid IC includes a MILSTD-1553 dual transceiver, memory-management circuitry, processor interface logic circuitry, and 64Kx16 bits of shared static random access memory. The memory is used to configure message and data blocks. In addition, 23 16-bit registers are available for (1) configuring the hybrid IC for, and starting it in, various modes of operation; (2) reading the status of the functionality of the hybrid IC; and (3) resetting the hybrid IC to a known state. The miniBIC can operate as a remote terminal, bus controller, or bus monitor. The FPGA provides the chip-select and data-strobe signals needed for operation of the hybrid ICs. The FPGA also receives interruption signals and forwards them to the ISA bus. The ISA interface connects the address, data, and control interfaces of the hybrid ICs to the ISA backplane. Each channel is, in effect, a MIL-STD-1553 interface that can operate either independently of the others or else as a redundant version of one of the others. The transformer in each channel provides electrical isolation between the rest of the miniBIC circuitry and the bus to which that channel is connected.
DC Voltage Interface Standards for Naval Applications
2015-06-24
norbert.doerry@navy.mil Dr. John Amy Naval Sea Systems Command United States Navy Washington DC , USA john.amy@navy.mil Abstract—. MIL-STD-1399...standards have been established for DC interfaces on U.S. naval surface ships. This paper provides recommendations for specific standard DC
NASA Technical Reports Server (NTRS)
Rogers, J. G.
1972-01-01
The major conclusion of the detailed examination of the human factors engineering design standard is that it is unsuitable for future spacecraft design. The standard, published in 1966, was not intended to be a zero or reduced gravity standard and was directed primarily toward ground support equipment and technology. Futhermore, ambiguities, conflicts, and unenforceable requirements contribute to the difficulty. The role of man in future space missions and its impact on human engineering standards are also discussed, and it is concluded that greater standardization is vital to the success of future missions. A survey of NASA/MSFC contractors was made, and it was found that MSFC-STD-267A is largely ignored and the most significant problems are inaccessibility and nonspecificity of the data. The resistance of contract management and designer and of program managers is a primary reason for poor human engineering design. Specific recommendations for improvement of format and organization, including an interim solution, are given.
NASA Astrophysics Data System (ADS)
Lim, Hyunjung; Jo, Ga Eun; Kim, Kyong Soo; Back, Seung Min; Choi, Hyuk
2017-05-01
Sexually transmitted disease (STD) is among the most common infectious diseases; therefore, it is necessary to develop sensitive early diagnostic techniques. As the gold standard, polymerase chain reaction (PCR) has been most widely employed for STD diagnosis; however, PCR requires large and expensive instruments. In this study, miniaturized thermal cycler using Peltier modules was developed for the PCR analysis. In comparison with the conventional PCR instrument, the Peltier-based micro-PCR (P-mPCR) device developed in this study enables one to amplify and successfully distinguish between DNA of different sizes. Furthermore, by using the clinical vaginal sample collected with the vaginal swab and tampon, different kinds of STD bacteria could be detected with high accuracy (˜94.19%) and high sensitivity (˜95.6%). Therefore, the P-mPCR device will be applicable in STD diagnosis as well as the detection of other bacteria/viruses using DNA amplification in regions including those with limited resources.
An Evaluation of an Ada Implementation of the Rete Algorithm for Embedded Flight Processors
1990-12-01
computers was desired. The VAX VMS operating system has many built-in methods for determining program performance (including VAX PCA), but these methods... overviev , of the target environment-- the MIL-STD-1750A VHSIC Avionic Modular Processor ( VA.IP, running under the Ada Avionics Real-Time Software (AARTS... computers . Mil-STD-1750A, the Air Force’s standard flight computer architecture, however, places severe constraints on applications software processing
10 CFR 431.63 - Materials incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... go to http://www.ansi.org: (1) ANSI /AHAM HRF-1-2004, Energy, Performance and Capacity of Household..., VA 22203, or http://www.ari.org/std/standards.html: (1) ARI Standard 1200-2006, Performance Rating of...
NASA-STD-6001B Test 1 Upward Flame Propagation; Sample Length Impact on MOC Investigation
NASA Technical Reports Server (NTRS)
Harper, Susana Tapia; Juarez, Alfredo; Woods, Brenton L.; Beeson, Harold D.
2017-01-01
Understanding the combustion behavior of materials in the elevated oxygen environments of habitable spacecraft is of utmost importance to crew safety and mission success. Currently, certification for unrestricted flight usage of a material with respect to flammability involves passing the Upward Flame Propagation Test of NASA-STD-6001B (Test 1). This test evaluates materials in a standardized test configuration for two failure criteria: self-extinguishment within 15 cm (6 in.) and the propensity of flame propagation by means of flaming material transfer. By the NASA standard, full-length samples are 30 cm (12 in.) in length; however, factors independent of the test method such as limited material availability or various nonstandard test configurations limit the full pretest sample lengths available for test. This paper characterizes the dependence, if any, of pretest sample length on NASA-STD-6001B Test 1 results. Testing was performed using the Maximum Oxygen Concentration (MOC) Threshold Method to obtain a data set for each sample length tested. In addition, various material types, including cloth (Nomex), foam (TA-301) and solids (Ultem), were tested to investigate potential effects of test specimen types. Though additional data needs to be generated to provide statistical confidence, preliminary findings are that use of variable sample lengths has minimal impact on NASA-STD-6001B flammability performance and MOC determination.
NASA Astrophysics Data System (ADS)
Solomon, Justin; Rubin, Geoffrey; Smith, Taylor; Harrawood, Brian; Choudhury, Kingshuk Roy; Samei, Ehsan
2017-03-01
The purpose of this study was to develop metrics of local anatomical complexity and compare them with detectability of lung nodules in CT. Data were drawn retrospectively from a published perception experiment in which detectability was assessed in cases enriched with virtual nodules (13 radiologists x 157 total nodules = 2041 responses). A local anatomical complexity metric called the distractor index was developed, defined as the Gaussian weighted proportion (i.e., average) of distracting local voxels (50 voxels in-plane, 5 slices). A distracting voxel was classified by thresholding image data that had been selectively filtered to enhance nodule-like features. The distractor index was measured for each nodule location in the nodule-free images. The local pixel standard deviation (STD) was also measured for each nodule. Other confounding factors of search fraction (proportion of lung voxels to total voxels in the given slice) and peripheral distance (defined as the 3D distance of the nodule from the trachea bifurcation) were measured. A generalized linear mixed-effects statistical model (no interaction terms, probit link function, random reader term) was fit to the data to determine the influence of each metric on detectability. In order of decreasing effect size: distractor index, STD, and search fraction all significantly affected detectability (P < 0.001). Distance to the trachea did not have a significant effect (P < 0.05). These data demonstrate that local lung complexity degrades detection of lung nodules and the distractor index could serve as a good surrogate metric to quantify anatomical complexity.
Automated microwave ablation therapy planning with single and multiple entry points
NASA Astrophysics Data System (ADS)
Liu, Sheena X.; Dalal, Sandeep; Kruecker, Jochen
2012-02-01
Microwave ablation (MWA) has become a recommended treatment modality for interventional cancer treatment. Compared with radiofrequency ablation (RFA), MWA provides more rapid and larger-volume tissue heating. It allows simultaneous ablation from different entry points and allows users to change the ablation size by controlling the power/time parameters. Ablation planning systems have been proposed in the past, mainly addressing the needs for RFA procedures. Thus a planning system addressing MWA-specific parameters and workflows is highly desirable to help physicians achieve better microwave ablation results. In this paper, we design and implement an automated MWA planning system that provides precise probe locations for complete coverage of tumor and margin. We model the thermal ablation lesion as an ellipsoidal object with three known radii varying with the duration of the ablation and the power supplied to the probe. The search for the best ablation coverage can be seen as an iterative optimization problem. The ablation centers are steered toward the location which minimizes both un-ablated tumor tissue and the collateral damage caused to the healthy tissue. We assess the performance of our algorithm using simulated lesions with known "ground truth" optimal coverage. The Mean Localization Error (MLE) between the computed ablation center in 3D and the ground truth ablation center achieves 1.75mm (Standard deviation of the mean (STD): 0.69mm). The Mean Radial Error (MRE) which is estimated by comparing the computed ablation radii with the ground truth radii reaches 0.64mm (STD: 0.43mm). These preliminary results demonstrate the accuracy and robustness of the described planning algorithm.
ISS Crew Transportation and Services Requirements Document
NASA Technical Reports Server (NTRS)
Lueders, Kathryn L. (Compiler)
2015-01-01
Under the guidance of processes provided by Crew Transportation Plan (CCT-PLN-1100), this document with its sister documents, Crew Transportation Technical Management Processes (CCT-PLN-1120), Crew Transportation Technical Standards and Design Evaluation Criteria (CCT-STD-1140), and Crew Transportation Operations Standards (CCT-STD-1150), and International Space Station (ISS) to Commercial Orbital Transportation Services Interface Requirements Document (SSP 50808), provides the basis for a National Aeronautics and Space Administration (NASA) certification for services to the ISS for the Commercial Provider. When NASA Crew Transportation System (CTS) certification is achieved for ISS transportation, the Commercial Provider will be eligible to provide services to and from the ISS during the services phase of the NASA Commercial Crew Program (CCP).
NASA Astrophysics Data System (ADS)
Zhang, Kai; Yang, Fanlin; Zhang, Hande; Su, Dianpeng; Li, QianQian
2017-06-01
The correlation between seafloor morphological features and biological complexity has been identified in numerous recent studies. This research focused on the potential for accurate characterization of coral reefs based on high-resolution bathymetry from multiple sources. A standard deviation (STD) based method for quantitatively characterizing terrain complexity was developed that includes robust estimation to correct for irregular bathymetry and a calibration for the depth-dependent variablity of measurement noise. Airborne lidar and shipborne sonar bathymetry measurements from Yuanzhi Island, South China Sea, were merged to generate seamless high-resolution coverage of coral bathymetry from the shoreline to deep water. The new algorithm was applied to the Yuanzhi Island surveys to generate maps of quantitive terrain complexity, which were then compared to in situ video observations of coral abundance. The terrain complexity parameter is significantly correlated with seafloor coral abundance, demonstrating the potential for accurately and efficiently mapping coral abundance through seafloor surveys, including combinations of surveys using different sensors.
Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung
2015-01-01
Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes. PMID:25830058
Cho, GyeYoon; Han, KyuChul; Yoon, JinYoung
2015-03-01
Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes.
Determinants of Pain Treatment Response and Non-Response: Identification of TMD Patient Subgroups
Litt, Mark D.; Porto, Felipe B.
2013-01-01
The purpose of the present study was to determine if we could identify a specific subtype of temporomandibular disorder (TMD) pain patients that does not respond to treatment. Patients were 101 men and women with chronic TMD pain recruited from the community and randomly assigned to one of two treatment conditions: a standard conservative care (STD) condition or a standard care plus cognitive-behavioral treatment condition (STD+CBT) in which patients received all elements of STD, but also received cognitive-behavioral coping skills training. Growth mixture modeling, incorporating a series of treatment-related predictors, was used to distinguish several distinct classes of responders or non-responders to treatment based on reported pain over a one-year follow-up period. Results indicated that treatment non-responders accounted for 16% of the sample, and did not differ from treatment responders on demographics or temporomandibular joint pathology, but that they reported more psychiatric symptoms, poorer coping, and higher levels of catastrophizing. Treatment-related predictors of membership in treatment responder groups versus the non-responder group included the addition of CBT to standard treatment, treatment attendance, and decreasing catastrophization. It was concluded that CBT may be made more efficacious for TMD patients by placing further emphasis on decreasing catastrophization and on individualizing care. PMID:24094979
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-15
...-2009-BT-STD-0022] RIN 1904-AC06 Energy Conservation Program for Consumer Products: Energy Conservation... that DOE plans to analyze for purposes of amending energy conservation standards for certain... persons may submit comments, identified by the notice title, the NOPM for Energy Conservation Standards...
TU-AB-BRA-01: Abdominal Synthetic CT Generation in Support of Liver SBRT Dose Calculation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bredfeldt, JS; Liu, L; Feng, M
2016-06-15
Purpose: To demonstrate and validate a technique for generating MRI-derived synthetic CT volumes (MRCTs) in support of adaptive liver SBRT. Methods: Under IRB approval, ten hepatocellular carcinoma patients were scanned using a single MR sequence (T1 Dixon-VIBE), yielding inherently-registered water, fat, and T1-weighted images. Air-containing voxels were identified by intensity thresholding. The envelope of the anterior vertebral bodies was segmented from the fat image by fitting a shape model to vertebral body candidate voxels, then using level sets to expand the contour outward. Fuzzy-C-Means (FCM) was then used to classify each non-air voxel in the image as fat, water, bone,more » or marrow. Bone and marrow only were classified within the vertebral body envelope. The MRCT was created by integrating the product of the FCM class probability with the assigned class density for each voxel. The resulting MRCTs were deformably aligned with planning CTs and 2-ARC SBRT VMAT plans were optimized on the MRCT density maps. Fluence was copied onto the CT density grids and dose recalculated. Results: The MRCTs faithfully reproduced most of the features visible in the corresponding CT image volumes, with exceptions of ribs and posterior spinous processes. The liver, vertebral bodies, kidneys, spleen and cord all had median HU differences of less than 75 between MRCT and CT images. PTV D99% values had an average 0.2% difference (standard deviation: 0.46%) between calculations on MRCT and CT density grids. The maximum difference in dose to 0.1cc of the PTV was 0.25% (std:0.49%). OAR dose differences were similarly small (mean:0.03Gy, std:0.26Gy). The largest normal tissue complication percentage (NTCP) difference was 1.48% (mean:0.06%, std:0.54%). Conclusions: MRCTs from a single abdominal imaging sequence are promising for use in SBRT dose calculation. Future work will focus on extending models to better define bones in the upper abdomen. Supported by NIHR01EB016079 and NIH1L30CA199594-01.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stowe, M; Gupta, N; Raterman, B
Purpose: To quantify the magnitude of geometric distortion for MRI scanners and provide recommendations for MRI imaging for radiation therapy Methods: A novel phantom, QUASAR MRID3D [Modus Medical Devices Inc.], was scanned to evaluate the level of 3D geometric distortion present in five MRI scanners used for radiation therapy in our department. The phantom was scanned using the body coil with 1mm image slice thickness to acquire 3D images of the phantom body. The phantom was aligned to its geometric center for each scan, and the field of view was set to visualize the entire phantom. The dependence of distortionmore » magnitude with distance from imaging isocenter and with magnetic field strength (1.5T and 3T) was investigated. Additionally, the characteristics of distortion for Siemens and GE machines were compared. The image distortion for each scanner was quantified in terms of mean, standard deviation (STD), maximum distortion, and skewness. Results: The 3T and 1.5T scans show a similar absolute distortion with a mean of 1.38mm (0.33mm STD) for 3T and 1.39mm (0.34mm STD) for 1.5T for a 100mm radius distance from isocenter. Some machines can have a distortion larger than 10mm at a distance of 200mm from the isocenter. The distortions are presented with plots of the x, y, and z directional components. Conclusion: The results indicate that quantification of MRI image distortion is crucial in radiation oncology for target and organ delineation and treatment planning. The magnitude of geometric distortion determines the margin needed for target contouring which is usually neglected in treatment planning process, especially for SRS/SBRT treatments. Understanding the 3D distribution of the MRI image distortion will improve the accuracy of target delineation and, hence, treatment efficacy. MRI imaging with proper patient alignment to the isocenter is vital to reducing the effects of MRI distortion in treatment planning.« less
Dialysis Dose Scaled to Body Surface Area and Size-Adjusted, Sex-Specific Patient Mortality
Kapke, Alissa; Port, Friedrich K.; Wolfe, Robert A.; Saran, Rajiv; Pearson, Jeffrey; Hirth, Richard A.; Messana, Joseph M.; Daugirdas, John T.
2012-01-01
Summary Background and objectives When hemodialysis dose is scaled to body water (V), women typically receive a greater dose than men, but their survival is not better given a similar dose. This study sought to determine whether rescaling dose to body surface area (SA) might reveal different associations among dose, sex, and mortality. Design, setting, participants, & measurements Single-pool Kt/V (spKt/V), equilibrated Kt/V, and standard Kt/V (stdKt/V) were computed using urea kinetic modeling on a prevalent cohort of 7229 patients undergoing thrice-weekly hemodialysis. Data were obtained from the Centers for Medicare & Medicaid Services 2008 ESRD Clinical Performance Measures Project. SA-normalized stdKt/V (SAN-stdKt/V) was calculated as stdKt/V × ratio of anthropometric volume to SA/17.5. Patients were grouped into sex-specific dose quintiles (reference: quintile 1 for men). Adjusted hazard ratios (HRs) for 1-year mortality were calculated using Cox regression. Results spKt/V was higher in women (1.7±0.3) than in men (1.5±0.2; P<0.001), but SAN-stdKt/V was lower (women: 2.3±0.2; men: 2.5±0.3; P<0.001). For both sexes, mortality decreased as spKt/V increased, until spKt/V was 1.6–1.7 (quintile 4 for men: HR, 0.62; quintile 3 for women: HR, 0.64); no benefit was observed with higher spKt/V. HR for mortality decreased further at higher SAN-stdKt/V in both sexes (quintile 5 for men: HR, 0.69; quintile 5 for women: HR, 0.60). Conclusions SA-based dialysis dose results in dose-mortality relationships substantially different from those with volume-based dosing. SAN-stdKt/V analyses suggest women may be relatively underdosed when treated by V-based dosing. SAN-stdKt/V as a measure for dialysis dose may warrant further study. PMID:22977208
Warner, Lee; Klausner, Jeffrey D; Rietmeijer, Cornelis A; Malotte, C. Kevin; O'Donnell, Lydia; Margolis, Andrew D; Greenwood, Gregory L; Richardson, Doug; Vrungos, Shelley; O'Donnell, Carl R; Borkowf, Craig B
2008-01-01
Background Sexually transmitted disease (STD) prevention remains a public health priority. Simple, practical interventions to reduce STD incidence that can be easily and inexpensively administered in high-volume clinical settings are needed. We evaluated whether a brief video, which contained STD prevention messages targeted to all patients in the waiting room, reduced acquisition of new infections after that clinic visit. Methods and Findings In a controlled trial among patients attending three publicly funded STD clinics (one in each of three US cities) from December 2003 to August 2005, all patients (n = 38,635) were systematically assigned to either a theory-based 23-min video depicting couples overcoming barriers to safer sexual behaviors, or the standard waiting room environment. Condition assignment alternated every 4 wk and was determined by which condition (intervention or control) was in place in the clinic waiting room during the patient's first visit within the study period. An intent-to-treat analysis was used to compare STD incidence between intervention and control patients. The primary endpoint was time to diagnosis of incident laboratory-confirmed infections (gonorrhea, chlamydia, trichomoniasis, syphilis, and HIV), as identified through review of medical records and county STD surveillance registries. During 14.8 mo (average) of follow-up, 2,042 patients (5.3%) were diagnosed with incident STD (4.9%, intervention condition; 5.7%, control condition). In survival analysis, patients assigned to the intervention condition had significantly fewer STDs compared with the control condition (hazard ratio [HR], 0.91; 95% confidence interval [CI], 0.84 to 0.99). Conclusions Showing a brief video in STD clinic waiting rooms reduced new infections nearly 10% overall in three clinics. This simple, low-intensity intervention may be appropriate for adoption by clinics that serve similar patient populations. Trial registration: http://www.ClinicalTrials.gov (#NCT00137670). PMID:18578564
49 CFR 395.18 - Matter incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Technology—Telecommunications and information exchange between systems—Local and metropolitan area networks...) Specifications,” IEEE Computer Society, Sponsored by the LAN/MAN Standards Committee: June 12, 2007 (IEEE Std... 446-2008, American National Standard for Information Technology—Identifying Attributes for Named...
40 CFR 80.1405 - What are the Renewable Fuel Standards?
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard for 2010 shall be 0.004 percent. (2) The value of the biomass-based diesel standard for 2010 shall... = The biomass-based diesel standard for year i, in percent. StdAB,i = The advanced biofuel standard for... volume of biomass-based diesel required by section 211(o)(2)(B) of the Clean Air Act for year i, in...
Braun, William E; Schold, Jesse D; Stephany, Brian R; Spirko, Rita A; Herts, Brian R
2014-05-01
The two largest studies of mammalian target of rapamycin inhibitor treatment of autosomal dominant polycystic kidney disease (ADPKD) demonstrated no clear benefit on the primary endpoint of total kidney volume (TKV) or on eGFR. The present study evaluated two levels of rapamycin on the 12-month change in (125)I-iothalamate GFR (iGFR) as the primary endpoint and TKV secondarily. In a 12-month open-label pilot study, 30 adult patients with ADPKD were randomly assigned to low-dose (LD) rapamycin (rapamycin trough blood level, 2-5 ng/ml) (LD group, n=10), standard-dose (STD) rapamycin trough level (>5-8 ng/ml) (STD group, n=10), or standard care (SC group, n=10). They were evaluated with iGFR and noncontrast computed tomography. Change in iGFR at 12 months was significantly higher in the LD group (7.7±12.5 ml/min per 1.73 m(2); n=9) than in the SC group (-11.2 ± 9.1 ml/min per 1.73 m(2); n=9) (LD versus SC: P<0.01). Change in iGFR at 12 months in the STD group (1.6 ± 12.1 ml/min per 1.73 m(2); n=8) was not significantly greater than that in the SC group (P=0.07), but it was in the combined treatment groups (LD+STD versus SC: P<0.01). Neither eGFR calculated by the CKD-Epidemiology Collaboration equation nor TKV (secondary endpoint) changed significantly from baseline to 12 months in any of the groups. On the basis of results of the mixed model, during the study, patients in the LD group had significantly lower trough blood levels of rapamycin (mean range ± SD, 2.40 ± 0.64 to 2.90 ± 1.20 ng/ml) compared with those in the STD group (3.93 ± 2.27 to 5.77 ± 1.06 ng/ml) (P<0.01). Patients with ADPKD receiving LD rapamycin demonstrated a significant increase in iGFR compared with those receiving standard care, without a significant effect on TKV after 12 months.
1987-12-01
support durring the first few years of operations, which provides an incentive for such innovations and defers the acquisition of AGE until the equipment...along with number of standard avionics programs worked and the ranks of each individual. Table 5. Expierence With Avionics Standardization Years
2015-03-26
sciences. According to the article, gender stereotyping was still an issue for women in STEM while treatment in other fields improved. The authors...Minimum Maximum Sum Mean Std. Deviation Gender DV (1= Male ) .00 1.00 50.00 .7692 .42460 Google Scholar Articles 0 192 2658 42.87 38.863 Years...Predictors: (Constant), Gender DV (1= Male ) Dependent Variable: Rank Results of analysis supported the hypothesis that gender is a predictor of the
Investigation of discrete component chip mounting technology for hybrid microelectronic circuits
NASA Technical Reports Server (NTRS)
Caruso, S. V.; Honeycutt, J. O.
1975-01-01
The use of polymer adhesives for high reliability microcircuit applications is a radical deviation from past practices in electronic packaging. Bonding studies were performed using two gold-filled conductive adhesives, 10/90 tin/lead solder and Indalloy no. 7 solder. Various types of discrete components were mounted on ceramic substrates using both thick-film and thin-film metallization. Electrical and mechanical testing were performed on the samples before and after environmental exposure to MIL-STD-883 screening tests.
Burt, Richard D.; Oster, Alexandra M.; Golden, Mathew R.; Thiede, Hanne
2013-01-01
There is no gold standard for recruiting unbiased samples of men who have sex with men (MSM). To assess differing recruitment methods, we compared Seattle-area MSM samples from: venue-day-time sampling-based National HIV Behavioral Surveillance (NHBS) surveys in 2008 and 2011, random-digit-dialed (RDD) surveys in 2003 and 2006, and STD clinic patient data 2001–2011. We compared sociodemographics, sexual and drug-associated behavior, and HIV status and testing. There was generally good consistency between the two NHBS surveys and within STD clinic data across time. NHBS participants reported higher levels of drug-associated and lower levels of sexual risk than STD clinic patients. RDD participants differed from the other study populations in sociodemographics and some risk behaviors. While neither NHBS nor the STD clinic study populations may be representative of all MSM, both appear to provide consistent samples of MSM subpopulations across time that can provide useful information to guide HIV prevention. PMID:23900958
Network Extender for MIL-STD-1553 Bus
NASA Technical Reports Server (NTRS)
Marcus, Julius; Hanson, T. David
2003-01-01
An extender system for MIL-STD-1553 buses transparently couples bus components at multiple developer sites. The bus network extender is a relatively inexpensive system that minimizes the time and cost of integration of avionic systems by providing a convenient mechanism for early testing without the need to transport the usual test equipment and personnel to an integration facility. This bus network extender can thus alleviate overloading of the test facility while enabling the detection of interface problems that can occur during the integration of avionic systems. With this bus extender in place, developers can correct and adjust their own hardware and software before products leave a development site. Currently resident at Johnson Space Center, the bus network extender is used to test the functionality of equipment that, although remotely located, is connected through a MILSTD- 1553 bus. Inasmuch as the standard bus protocol for avionic equipment is that of MIL-STD-1553, companies that supply MIL-STD-1553-compliant equipment to government or industry and that need long-distance communication support might benefit from this network bus extender
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-03
...-2009-BT-STD-0018] RIN 1904-AC00 Energy Conservation Program: Energy Conservation Standards for Metal... certain metal halide lamp fixtures. This document announces that the period for submitting comments on the... identify the Framework Document for energy conservation standards for metal halide lamp fixtures and...
Space and Missile Systems Center Standard: Systems Engineering Requirements and Products
2013-07-01
unique hazard classification and explosive ordnance disposal requirements. (2) Operational and maintenance facilities and equipment requirements. (3...PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 FOREWORD 1. This standard defines the Government’s requirements...49 4.3.14 Electromagnetic Interference and
2017-07-01
8-3 8.4.1 Characteristics of a Singular Composite Output Signal ...................................... 8-3 8.5 Single Bus Track Spread Recording ...Format .............................................................. 8-5 8.5.1 Single Bus Recording Technique Characteristics...check FCS frame check sequence HDDR high-density digital recording MIL-STD Military Standard msb most significant bit PCM pulse code modulation
EMC and power quality standards for 20-kHz power distribution
NASA Technical Reports Server (NTRS)
Hansen, Irving G.
1987-01-01
The Space Station Power Distribution System has been baselined as a sinusoidal single phase, 440 VRMS system. This system has certain unique characteristics directly affecting its application. In particular, existing systematic description and control documents were modified to reflect the high operating frequency. This paper will discuss amendments made on Mil STD 704 (Electrical Power Characteristics), and Mil STD 461-B (Electromagnetic Emission and Susceptibility Requirements for the Control of Electromagnetic Interference). In some cases these amendments reflect changes of several orders of magnitude. Implications and impacts of these changes are discussed.
Hashimoto, S; Murakami, Y; Taniguchi, K; Nagai, M
1999-12-01
Our purpose was to determine the number of monitoring stations (medical institutions) necessary for estimating incidence rates in the surveillance system of infectious diseases in Japan. Infectious diseases were selected by the type of monitoring stations: 15 diseases in pediatrics stations, influenza in influenza stations, 3 diseases in ophthalmology stations and 5 diseases in the stations of sexually transmitted diseases (STD). For each type of monitoring station, 5 cases of the number of monitoring stations in each health center, including the number determined from presently established standards and the actual number in 1997, were given. It was assumed that monitoring stations were randomly selected among medical institutions in health centers. For each infectious disease, each case and each type of monitoring station, standard error rates of estimated numbers of incidence cases in the whole country were calculated in 1993-1997 using the data of the surveillance of infectious diseases. Among 5 cases of monitoring stations, the case satisfied the condition that those standard error rates were lower than the critical values, was selected. The critical values were 5% in pediatrics and influenza stations, and 10% in ophthalmology and STD stations. The numbers of monitoring stations in the selected cases were 3,000 in pediatrics stations, 5,000 in influenza stations (including all pediatrics stations), 605 in ophthalmology stations and 900 in STD stations.
NASA Astrophysics Data System (ADS)
Fu, Zewei; Hu, Juntao; Hu, Wenlong; Yang, Shiyu; Luo, Yunfeng
2018-05-01
Quantitative analysis of Ni2+/Ni3+ using X-ray photoelectron spectroscopy (XPS) is important for evaluating the crystal structure and electrochemical performance of Lithium-nickel-cobalt-manganese oxide (Li[NixMnyCoz]O2, NMC). However, quantitative analysis based on Gaussian/Lorentzian (G/L) peak fitting suffers from the challenges of reproducibility and effectiveness. In this study, the Ni2+ and Ni3+ standard samples and a series of NMC samples with different Ni doping levels were synthesized. The Ni2+/Ni3+ ratios in NMC were quantitatively analyzed by non-linear least-squares fitting (NLLSF). Two Ni 2p overall spectra of synthesized Li [Ni0.33Mn0.33Co0.33]O2(NMC111) and bulk LiNiO2 were used as the Ni2+ and Ni3+ reference standards. Compared to G/L peak fitting, the fitting parameters required no adjustment, meaning that the spectral fitting process was free from operator dependence and the reproducibility was improved. Comparison of residual standard deviation (STD) showed that the fitting quality of NLLSF was superior to that of G/L peaks fitting. Overall, these findings confirmed the reproducibility and effectiveness of the NLLSF method in XPS quantitative analysis of Ni2+/Ni3+ ratio in Li[NixMnyCoz]O2 cathode materials.
Parikh, Rajul S; Parikh, Shefali R; Kumar, Rajesh S; Prabakaran, S; Babu, J Gansesh; Thomas, Ravi
2008-07-01
To evaluate the diagnostic ability of scanning laser polarimetry (GDx variable corneal compensator [VCC]) for early glaucoma in Asian Indian eyes. Cross-sectional observational study. Two groups of patients (early glaucoma and normal) who satisfied the inclusion and exclusion criteria were included. Early glaucoma was diagnosed in presence of open angles, characteristic glaucomatous optic disc changes correlating with the visual field (VF) on automated perimetry (VF defect fulfilling at least 2 of 3 Anderson and Patella's criteria with mean deviation >or= -6 decibels). Normal subjects had visual acuity >or= 20/30 and intraocular pressure < 22 mmHg, with a normal optic disc and fields and no ocular abnormality. All patients underwent complete ophthalmic evaluation, including VF examination (24-2/30-2 Swedish interactive threshold algorithm standard program) and imaging with GDx VCC. Sensitivity, specificity, positive predictive value and negative predictive value, area under the receiving operating characteristic curve, and likelihood ratios (LRs) were calculated for various GDx VCC parameters. Seventy-four eyes (74 patients) with early glaucoma and 104 eyes (104 normal subjects) were enrolled. TSNIT Std Dev (temporal-superior-nasal-inferior-temporal standard deviation) had the best combination of sensitivity and specificity-61.3 and 95.2, respectively-followed by nerve fiber index score > 50 (sensitivity, 52.7%; specificity, 99%). Nerve fiber index score > 50 had positive and negative predictive values of 74.3% and 97.6%, respectively, for an assumed glaucoma prevalence of 5%. Nerve fiber index score > 50 had a positive LR (+LR) of 54.8 for early glaucoma. GDx VCC has moderate sensitivity, with high specificity, in the diagnosis of early glaucoma. The high +LR for the nerve fiber index score can provide valuable diagnostic information for individual patients.
Cooper, Ross G
2010-06-01
Zimbabwe has an incidence of STD/HIV infection and measures are needed to explore the efficiency of clinics in providing adequate patient care. To explore the views or opinions of the currently employed staff of an STD/HIV clinic, and suggest a means for improvement thereof. A current position analysis was determined through observation of an STD/HIV clinic. An assessment was made using an adapted, designed questionnaire as interviews of 125 staff. Responses to questions were given as Yes or No responses. Data were analysed according to gender, using a two-sample t-test and chi-square tests. Yates' correction was made for continuity of smaller samples. A value of p < 0.05 was taken a significant. The mean average age of all staff was 31.7 years and 75% of the respondents were female. Notably, there were massive shortages of staff, poor communication with the Ministry of Health, little or no training of staff, poor infrastructure and quality, and a drop in safety standards. There is poor communication in the clinic, insufficient staff and inadequate training in place. Monitoring of STD incidence needs drastic improvement. Operational research needs to be conducted. There is little or no direct communication between committee members and decision makers with the staff and power-distance relationships are great.
Tross, Susan; Campbell, Aimee N. C.; Cohen, Lisa R.; Calsyn, Donald; Pavlicova, Martina; Miele, Gloria; Hu, Mei-Chen; Haynes, Louise; Nugent, Nancy; Gan, Weijin; Hatch-Maillette, Mary; Mandler, Raul; McLaughlin, Paul; El-Bassel, Nabila; Crits-Christoph, Paul; Nunes, Edward V.
2009-01-01
Context Since drug-involved women are among the fastest growing groups with AIDS, sexual risk reduction intervention for them is a public health imperative. Objective Test effectiveness of HIV/STD safer sex skills building (SSB) groups for women in community drug treatment. Design Randomized trial of SSB versus standard HIV/STD Education (HE); assessments at baseline, 3- and 6- months Participants Women recruited from 12 methadone or psychosocial treatment programs in NIDA’s Clinical Trials Network. 515 women with ≥ one unprotected vaginal or anal sex occasion (USO) with a male partner in the past 6 months were randomized. Interventions In SSB, five 90-minute groups used problem-solving and skills rehearsal to increase HIV/STD risk awareness, condom use and partner negotiation skills. In HE, one 60-minute group covered HIV/STD disease, testing, treatment, and prevention information. Main Outcome Number of USOs at follow up. Results A significant difference in mean USOs was obtained between SSB and HE over time (F=67.2, p<.0001). At 3 months, significant decrements were observed in both conditions. At 6 months SSB maintained the decrease, HE returned to baseline (p<.0377). Women in SSB had 29% fewer USOs than those in HE. Conclusions Skills building interventions can produce ongoing sexual risk reduction in women in community drug treatment. PMID:18645513
Tross, Susan; Campbell, Aimee N C; Cohen, Lisa R; Calsyn, Donald; Pavlicova, Martina; Miele, Gloria M; Hu, Mei-Chen; Haynes, Louise; Nugent, Nancy; Gan, Weijin; Hatch-Maillette, Mary; Mandler, Raul; McLaughlin, Paul; El-Bassel, Nabila; Crits-Christoph, Paul; Nunes, Edward V
2008-08-15
Because drug-involved women are among the fastest growing groups with AIDS, sexual risk reduction intervention for them is a public health imperative. To test effectiveness of HIV/STD safer sex skills building (SSB) groups for women in community drug treatment. Randomized trial of SSB versus standard HIV/STD Education (HE); assessments at baseline, 3 and 6 months. Women recruited from 12 methadone or psychosocial treatment programs in Clinical Trials Network of National Institute on Drug Abuse. Five hundred fifteen women with >or=1 unprotected vaginal or anal sex occasion (USO) with a male partner in the past 6 months were randomized. In SSB, five 90-minute groups used problem solving and skills rehearsal to increase HIV/STD risk awareness, condom use, and partner negotiation skills. In HE, one 60-minute group covered HIV/STD disease, testing, treatment, and prevention information. Number of USOs at follow-up. A significant difference in mean USOs was obtained between SSB and HE over time (F = 67.2, P < 0.0001). At 3 months, significant decrements were observed in both conditions. At 6 months, SSB maintained the decrease and HE returned to baseline (P < 0.0377). Women in SSB had 29% fewer USOs than those in HE. Skills building interventions can produce ongoing sexual risk reduction in women in community drug treatment.
Russell, Marie; Silverman, Angela; Fleg, Jerome L; Lee, Elisa T; Mete, Mihriye; Weir, Matthew; Wilson, Charlton; Yeh, Fawn; Howard, Barbara V; Howard, W M James
2010-01-01
Although lipid management in diabetes is standard practice, goals often are neither met nor maintained. Strategies for achieving lower targets have not been explored. The Stop Atherosclerosis in Native Diabetics Study randomized patients with diabetes to standard versus aggressive lipid and blood pressure goals for 36 months. To report strategies used to achieve and maintain lipid goals and to report adverse events (AEs). Adults with type 2 diabetes and no history of cardiovascular disease (N = 499) were randomized to standard (low-density lipoprotein cholesterol [LDL-C] ≤ 100 mg/dL, non-high-density lipoprotein cholesterol [non-HDL-C] ≤ 130 mg/dL) or aggressive (LDL-C ≤ 70 mg/dL, non-HDL-C ≤ 100 mg/dL) targets. An algorithm was started with statin monotherapy, with intestinally acting agents added as required to reach LDL-C targets.Triglyceride [TG]-lowering agents were next used to reach non-HDL-C goals. Lipid management was performed by mid-level practitioners, with physician consultation, by the use of point-of-care lipid determinations. On average, both groups achieved the LDL-C and non-HDL-C goals within 12 months and maintained them throughout the study. At 36 months, mean (SD) LDL-C and non-HDL-C were 72 (24) and 102 (29) mg/dL in the aggressive group (AGG) and 104 (20) and 138 (26) mg/dL, respectively, in the standard group (STD); systolic blood pressure targets were 115 and 130 mmHg, respectively. A total of 68% of participants reached target LDL-C for greater than 50% of the visits and 46% for greater than 75% of visits. At 36 months, the AGG averaged 1.5 lipid lowering medications and the STD 1.2. Statins were used in 91% and 68% of the AGG and STD; ezetimibe by 31% and 10%; fibrates by 8% and 18%. No serious AEs were observed; AEs occurred in 18% of the AGG and 14% of the STD. Standard and aggressive lipid targets can be safely maintained in diabetic patients. Standardized algorithms, point-of-care lipid testing, and nonphysician providers facilitate care delivery. © 2010 National Lipid Association. All rights reserved.
106-17 Telemetry Standards Recorder and Reproducer Command and Control Chapter 6
2017-07-01
6-35 6.3 MIL-STD-1553 Remote Terminal Command and Control ..................................... 6-36 6.4 Discrete Command and...6-6 Figure 6-9. Required Discrete Control Functions...6-36 Figure 6-10. Discrete Control and Indicator Functional Diagram .......................................... 6-37 Telemetry Standards
NASA Astrophysics Data System (ADS)
Ermida, S. L.; Jiménez, C.; Prigent, C.; Trigo, I. F.; DaCamara, C. C.
2017-03-01
A comparison of land surface temperature (Ts) derived from the Advanced Microwave Scanning Radiometer-Earth Observing System (AMSR-E) with infrared Ts is presented. The infrared Ts include clear-sky estimates from the Moderate Resolution Imaging Spectroradiometer (MODIS), the Spinning Enhanced Visible and Infrared Imager, the Geostationary Operational Environmental Satellite (GOES) Imager, and the Japanese Meteorological Imager. The higher discrepancies between AMSR-E and MODIS are observed over deserts and snow-covered areas. The former seems to be associated with Ts underestimation by MODIS, whereas the latter is mostly related to uncertainties in microwave emissivity over snow/ice. Ts differences between AMSR-E and MODIS are significantly reduced after masking out snow and deserts, with a bias change from 2.6/4.6 K to 3.0/1.4 K for daytime/nighttime and a standard deviation (STD) decrease from 7.3/7.9 K to 5.1/3.9 K. When comparing with all infrared sensors, the STD of the differences between microwave and infrared Ts is generally higher than between IR retrievals. However, the biases between microwave and infrared Ts are, in some cases, of the same order as the ones observed between infrared products. This is the case for GOES, with daytime biases with respect to AMSR-E and MODIS of 0.45 K and 0.60 K, respectively. While the infrared Ts are clear-sky estimates, AMSR-E also provides Ts under cloudy conditions. For frequently cloudy regions, this results in a large increase of available Ts estimates (>250%), making the microwave Ts a very powerful complement of the infrared estimates.
The Surface Velocity Structure of the Florida Current in a Jet Coordinate Frame
NASA Astrophysics Data System (ADS)
Archer, Matthew R.; Shay, Lynn K.; Johns, William E.
2017-11-01
The structure and variability of the Florida Current between 25° and 26°N are investigated using HF radar ocean current measurements to provide the most detailed view of the surface jet to date. A 2-D jet coordinate analysis is performed to define lateral displacements of the jet in time (meandering), and associated structural variations over a 2 year period (2005-2006). In the jet coordinate frame, core speed has a median value of ˜160 cm s-1 at the central latitude of the array (25.4°N), with a standard deviation (STD) of 35 cm s-1. The jet meanders at timescales of 3-30 days, with a STD of 8 km, and a downstream phase speed of ˜80 km d-1. Meandering accounts for ˜45% of eddy kinetic energy computed in a fixed (geographical) reference frame. Core speed, width, and shear undergo the same dominant 3-30 day variability, plus an annual cycle that matches seasonality of alongshore wind stress. Jet transport at 25.4°N exhibits a different seasonality to volume transport at 27°N, most likely driven by input from the Northwest Providence Channel. Core speed correlates inversely with Miami sea level fluctuations such that a 40 cm s-1 deceleration is associated with a ˜10 cm elevation in sea level, although there is no correlation of sea level to jet meandering or width. Such accurate quantification of the Florida Current's variability is critical to understand and forecast future changes in the climate system of the North Atlantic, as well as local impacts on coastal circulation and sea level variability along south Florida's coastline.
Speech Adjustments for Room Acoustics and Their Effects on Vocal Effort.
Bottalico, Pasquale
2017-05-01
The aims of the present study are (1) to analyze the effects of the acoustical environment and the voice style on time dose (D t_p ) and fundamental frequency (mean f 0 and standard deviation std_f 0 ) while taking into account the effect of short-term vocal fatigue and (2) to predict the self-reported vocal effort from the voice acoustical parameters. Ten male and ten female subjects were recorded while reading a text in normal and loud styles, in three rooms-anechoic, semi-reverberant, and reverberant-with and without acrylic glass panels 0.5 m from the mouth, which increased external auditory feedback. Subjects quantified how much effort was required to speak in each condition on a visual analogue scale after each task. (Aim1) In the loud style, D t_p , f 0 , and std_f 0 increased. The D t_p was higher in the reverberant room compared to the other two rooms. Both genders tended to increase f 0 in less reverberant environments, whereas a more monotonous speech was produced in rooms with greater reverberation. All three voice parameters increased with short-term vocal fatigue. (Aim2) A model of the vocal effort to acoustic vocal parameters is proposed. The sound pressure level contributed to 66% of the variance explained by the model, followed by the f 0 (30%) and the modulation in amplitude (4%). The results provide insight into how voice acoustical parameters can predict vocal effort. In particular, it increased when SPL and f 0 increased and when the amplitude voice modulation decreased. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Montesano, Giovanni; Allegrini, Davide; Colombo, Leonardo; Rossetti, Luca M; Pece, Alfredo
2017-01-01
The main objective of our work is to perform an in depth analysis of the structural features of normal choriocapillaris imaged with OCT Angiography. Specifically, we provide an optimal radius for a circular Region of Interest (ROI) to obtain a stable estimate of the subfoveal choriocapillaris density and characterize its textural properties using Markov Random Fields. On each binarized image of the choriocapillaris OCT Angiography we performed simulated measurements of the subfoveal choriocapillaris densities with circular Regions of Interest (ROIs) of different radii and with small random displacements from the center of the Foveal Avascular Zone (FAZ). We then calculated the variability of the density measure with different ROI radii. We then characterized the textural features of choriocapillaris binary images by estimating the parameters of an Ising model. For each image we calculated the Optimal Radius (OR) as the minimum ROI radius required to obtain a standard deviation in the simulation below 0.01. The density measured with the individual OR was 0.52 ± 0.07 (mean ± STD). Similar density values (0.51 ± 0.07) were obtained using a fixed ROI radius of 450 μm. The Ising model yielded two parameter estimates (β = 0.34 ± 0.03; γ = 0.003 ± 0.012; mean ± STD), characterizing pixel clustering and white pixel density respectively. Using the estimated parameters to synthetize new random textures via simulation we obtained a good reproduction of the original choriocapillaris structural features and density. In conclusion, we developed an extensive characterization of the normal subfoveal choriocapillaris that might be used for flow analysis and applied to the investigation pathological alterations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heins, D; Zhang, R; Hogstrom, K
2016-06-15
Purpose: To determine if bolus electron conformal therapy (Bolus-ECT) combined with intensity modulated x-ray therapy (IMXT) and flattening filter free volumetric modulated arc therapy (FFF-VMAT (6x and 10x)) can maintain equal or better dose coverage than standard volumetric modulated arc therapy (Std-VMAT) while reducing doses to organs at risk (OARs). Methods: Bolus-ECT with IMXT, FFF-VMAT, and Std-VMAT treatment plans were produced for ten post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic. The treatment plans were created on commercially available treatment planning system (TPS) and all completed treatment plans were reviewed and approved by a radiation oncologist. The plans weremore » evaluated based on planning target volume (PTV) coverage, tumor control probability (TCP), dose homogeneity index (DHI), conformity index (CI), and dose to organs at risk (OAR). Results: All techniques produced clinically acceptable PMRT plans. Overall, Bolus-ECT with IMXT exhibited higher maximum dose compared to all VMAT techniques. Bolus-ECT with IMXT and FFF-VMAT10x had slightly improved TCP over FFF-VMAT6x and Std-VMAT. However, all VMAT techniques showed improved CI and DHI over Bolus-ECT with IMXT. All techniques showed very similar mean lung dose. Bolus-ECT with IMXT exhibited a reduced mean heart dose over Std-VMAT. Both FFF-VMAT techniques had higher mean heart dose compared to Std-VMAT. In addition, Bolus-ECT with IMXT was able to reduce mean dose to the contralateral breast compared to Std-VMAT and both FFF-VMAT techniques had comparable but slightly reduced dose compared to Std-VMAT. Conclusion: This work has shown that Bolus-ECT with IMXT produces clinically acceptable plans while reducing OAR doses. Both FFF-VMAT techniques are comparable to Std-VMAT with slight improvements. Even though all VMAT techniques produce more homogenous and conformal dose distributions, Bolus-ECT with IMXT is a viable option for treating post-mastectomy patients possibly leading to reduced risks of normal tissue complications.« less
2012 Sexually Transmitted Diseases Surveillance
... Data Appendix Tables A1 - A4 STD Surveillance Case Definitions Contributors Related Links STD Home STD Data & Statistics NCHHSTP Atlas Interactive STD Data - 1996-2013 STD Health Equity HIV/AIDS Surveillance & Statistics Follow STD STD on Twitter STD on Facebook File Formats Help: How do I view different ...
Empowering sex workers in India to reduce vulnerability to HIV and sexually transmitted diseases⋆
Swendeman, Dallas; Basu, Ishika; Das, Sankari; Jana, Smarajit; Rotheram-Borus, Mary Jane
2010-01-01
The Sonagachi Project was initiated in Kolkata, India in 1992 as a STD/HIV intervention for sex workers. The project evolved to adopt strategies common to women’s empowerment programs globally (i.e., community mobilization, rights-based framing, advocacy, micro-finance) to address common factors that support effective, evidence-based HIV/STD prevention. The Sonagachi model is now a broadly diffused evidence-based empowerment program. We previously demonstrated significant condom use increases among female sex workers in a 16 month replication trial of the Sonagachi empowerment intervention (n = 110) compared to a control community (n = 106) receiving standard care of STD clinic, condom promotion, and peer education in two randomly assigned rural towns in West Bengal, India (Basu et al., 2004). This article examines the intervention’s impacts on 21 measured variables reflecting five common factors of effective HIV/STD prevention programs to estimate the impact of empowerment strategies on HIV/STD prevention program goals. The intervention which was conducted in 2000–2001 significantly: 1) improved knowledge of STDs and condom protection from STD and HIV, and maintained STD/HIV risk perceptions despite treatment; 2) provided a frame to motivate change based on reframing sex work as valid work, increasing disclosure of profession, and instilling a hopeful future orientation reflected in desire for more education or training; 3) improved skills in sexual and workplace negotiations reflected in increased refusal, condom decision-making, and ability to change work contract, but not ability to take leave; 4) built social support by increasing social interactions outside work, social function participation, and helping other sex workers; and 5) addressed environmental barriers of economic vulnerabilities by increasing savings and alternative income, but not working in other locations, nor reduced loan taking, and did not increase voting to build social capital. This study’s results demonstrate that, compared to narrowcast clinical and prevention services alone, empowerment strategies can significantly impact a broader range of factors to reduce vulnerability to HIV/STDs. PMID:19716639
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amini, Arya; Westerly, David C.; Waxweiler, Timothy V.
Targeted focal therapy strategies for treating single-lobe prostate cancer are under investigation. In this planning study, we investigate the feasibility of treating a portion of the prostate to full-dose external beam radiation with reduced dose to the opposite lobe, compared with full-dose radiation delivered to the entire gland using hypofractionated radiation. For 10 consecutive patients with low- to intermediate-risk prostate cancer, 2 hypofractionated, single-arc volumetric-modulated arc therapy (VMAT) plans were designed. The first plan (standard hypofractionation regimen [STD]) included the entire prostate gland, treated to 70 Gy delivered in 28 fractions. The second dose painting plan (DP) encompassed the involvedmore » lobe treated to 70 Gy delivered in 28 fractions, whereas the opposing, uninvolved lobe received 50.4 Gy in 28 fractions. Mean dose to the opposing neurovascular bundle (NVB) was considerably lower for DP vs STD, with a mean dose of 53.9 vs 72.3 Gy (p < 0.001). Mean penile bulb dose was 18.6 Gy for DP vs 19.2 Gy for STD (p = 0.880). Mean rectal dose was 21.0 Gy for DP vs 22.8 Gy for STD (p = 0.356). Rectum V{sub 70} (the volume receiving ≥70 Gy) was 2.01% for DP vs 2.74% for STD (p = 0.328). Bladder V{sub 70} was 1.69% for DP vs 2.78% for STD (p = 0.232). Planning target volume (PTV) maximum dose points were 76.5 and 76.3 Gy for DP and STD, respectively (p = 0.760). This study demonstrates the feasibility of using VMAT for partial-lobe prostate radiation in patients with prostate cancer involving 1 lobe. Partial-lobe prostate plans appeared to spare adjacent critical structures including the opposite NVB.« less
Empowering sex workers in India to reduce vulnerability to HIV and sexually transmitted diseases.
Swendeman, Dallas; Basu, Ishika; Das, Sankari; Jana, Smarajit; Rotheram-Borus, Mary Jane
2009-10-01
The Sonagachi Project was initiated in Kolkata, India in 1992 as a STD/HIV intervention for sex workers. The project evolved to adopt strategies common to women's empowerment programs globally (i.e., community mobilization, rights-based framing, advocacy, micro-finance) to address common factors that support effective, evidence-based HIV/STD prevention. The Sonagachi model is now a broadly diffused evidence-based empowerment program. We previously demonstrated significant condom use increases among female sex workers in a 16 month replication trial of the Sonagachi empowerment intervention (n=110) compared to a control community (n=106) receiving standard care of STD clinic, condom promotion, and peer education in two randomly assigned rural towns in West Bengal, India (Basu et al., 2004). This article examines the intervention's impacts on 21 measured variables reflecting five common factors of effective HIV/STD prevention programs to estimate the impact of empowerment strategies on HIV/STD prevention program goals. The intervention which was conducted in 2000-2001 significantly: 1) improved knowledge of STDs and condom protection from STD and HIV, and maintained STD/HIV risk perceptions despite treatment; 2) provided a frame to motivate change based on reframing sex work as valid work, increasing disclosure of profession, and instilling a hopeful future orientation reflected in desire for more education or training; 3) improved skills in sexual and workplace negotiations reflected in increased refusal, condom decision-making, and ability to change work contract, but not ability to take leave; 4) built social support by increasing social interactions outside work, social function participation, and helping other sex workers; and 5) addressed environmental barriers of economic vulnerabilities by increasing savings and alternative income, but not working in other locations, nor reduced loan taking, and did not increase voting to build social capital. This study's results demonstrate that, compared to narrowcast clinical and prevention services alone, empowerment strategies can significantly impact a broader range of factors to reduce vulnerability to HIV/STDs.
40 CFR 89.207 - Credit calculation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... determining credit availability from all engine families generating credits: Emission credits = (Std−FEL... families requiring credits to offset emissions in excess of the standard: Emission credits = (Std−FEL) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard...
40 CFR 89.207 - Credit calculation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... determining credit availability from all engine families generating credits: Emission credits = (Std−FEL... families requiring credits to offset emissions in excess of the standard: Emission credits = (Std−FEL) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard...
40 CFR 89.207 - Credit calculation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... determining credit availability from all engine families generating credits: Emission credits = (Std−FEL... families requiring credits to offset emissions in excess of the standard: Emission credits = (Std−FEL) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-04
...-2010-BT-STD-0048] RIN 1904-AC04 Energy Conservation Standards for Distribution Transformers: Public... information that it is making available about the liquid-immersed distribution transformer equipment classes... equipment classes for several different types of liquid-immersed distribution transformers. In addition to...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-03
...-BT-STD-0005] RIN 1904-AC15 Energy Conservation Program for Consumer Products: Energy Conservation... Conservation Act (EPCA), the U.S. Department of Energy (DOE) is preparing a notice of proposed rulemaking regarding energy conservation standards for certain incandescent reflector lamps (IRLs) that have elliptical...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-22
... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2011-BT-STD-0047] RIN 1904-AC56 Energy Conservation Program: Energy Conservation Standards for Direct Heating Equipment AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of proposed rulemaking and announcement...
77 FR 59712 - Energy Conservation Program: Energy Conservation Standards for Dishwashers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... DEPARTMENT OF ENERGY 10 CFR Parts 429 and 430 [Docket Number EERE-2011-BT-STD-0060] RIN 1904-AC64 Energy Conservation Program: Energy Conservation Standards for Dishwashers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of effective date and compliance dates...
Effects of milk replacer program fed 2 or 4 times daily on nutrient intake and calf growth.
Kmicikewycz, A D; da Silva, D N L; Linn, J G; Litherland, N B
2013-02-01
The aims of this study were to determine if feeding frequency (FF) of milk replacer (MR; meals/d) alters starter intake, growth, and efficiency of growth in nursery calves fed a conventional or accelerated MR. We hypothesized that smaller and more frequent MR meals would increase starter intake and growth when greater amounts of MR nutrients are fed to nursery calves. Forty-eight Holstein and Holstein-cross heifer and bull calves were assigned to treatments in a 2 × 2 factorial arrangement of MR and FF. Treatments included (1) standard 20% CP and 20% fat MR fed at 1.5% of body weight (BW; 2 meals/d; STD2), (2) standard 20% CP and 20% fat MR fed at 1.5% of BW (4 meals/d; STD4), (3) modified 26% CP and 18% fat MR fed at 2.0% of BW (2 meals/d; MOD2), and (4) modified 26% CP and 18% fat MR fed at 2.0% of BW (4 meals/d; MOD4; n=12). All calves were fed at 0600 and 1700 h and STD4 and MOD4 calves were fed 2 additional meals at 1100 and 1400 h, resulting in the same amount of MR offered for the 2 × and 4 × treatments. Treatments were fed from d 2 to 42 of age and all MR feeding rates were adjusted weekly to maintain MR solids intakes at 1.5 or 2.0% of BW for STD and MOD diets, respectively, and were reconstituted to 15% total solids. Milk replacer FF was reduced by 50% on d 36 and calves were weaned on d 42. Calves were housed in hutches bedded with straw and offered water and a texturized 18% CP starter ad libitum. Calf body weight and body structure were measured weekly and starter intake and fecal scores were measured daily. Through both 42 and 56 d, calves fed MOD had greater CP and fat intake, resulting in increased average daily gain, heart girth, circulating nonesterified fatty acids (NEFA), and muscle total lipid compared with calves fed STD diets. Calves fed MOD diets consumed less starter grain than STD calves but total dry matter intake was similar among treatments. Increased FF for STD calves resulted in greater starter intake at weaning but increasing FF of MOD calves did not have this effect. Due to differences in starter intake, total dry matter by calves through d 56 was similar across treatments. Additionally, increased FF tended to increase serum NEFA concentrations. Serum NEFA concentration was negatively correlated with starter intake. The BW of calves fed STD2 and STD4 treatments almost doubled and the BW of calves on the MOD2 and MOD4 treatments doubled by d 56. Increased FF of the conventional MR program but not accelerated MR program increased starter intake. Increased FF did not affect growth, starter intake, or gain:feed ratio. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Scarborough, Ashley P; Slome, Sally; Hurley, Leo B; Park, Ina U
2015-10-01
Screening for gonorrhea (GC) and chlamydia (CT) and syphilis among HIV-positive (HIV+) men who have sex with men (MSM) is recommended at least annually. However, significant gaps in screening coverage exist. We conducted a quality improvement intervention to determine whether informing providers of preintervention screening rates and routinizing sexual risk assessment would improve sexually transmitted disease (STD) screening in a large HIV care clinic. In partnership with Kaiser Permanente Northern California, we developed and implemented a 10-item assessment addressing sexual and other behavioral risk factors among HIV+ MSM. We analyzed the proportion of patients screened for GC/CT and syphilis in a preintervention period (June 25-September 26, 2012) and during the intervention period (June 25-September 26, 2013). Of 364 HIV+ MSM seen for care during the intervention period, 47.3% completed the sexual risk assessment. Improvements in GC/CT screening and syphilis screening were observed; when comparing the preintervention period with the intervention period, the proportion of HIV+ MSM receiving GC/CT screening increased by 26.8% (31.6%-40.1%, P = 0.01) at any anatomical site and by 45% (19.5%-28.3%, P = 0.003) at the pharyngeal site. Syphilis screening significantly increased by 18.8% (48.7%-58.0%, P = 0.009). Overall STD screening increases were observed after this intervention that included didactic training on the urgency of STD screening needs for HIV+ MSM, a presentation of preintervention clinic STD screening data, and the implementation of self-reported sexual risk assessment. Additional efforts are needed to determine feasible ways to accurately assess the appropriateness of STD screening and success of interventions to improve STD screening.
Celentano, David D; Mayer, Kenneth H; Pequegnat, Willo; Abdala, Nadia; Green, Annette M; Handsfield, H Hunter; Hartwell, Tyler D
2010-01-01
This cross-sectional study describes the baseline prevalence and correlates of common bacterial and viral sexually transmitted diseases (STDs) and risk behaviors among individuals at high risk for HIV recruited in five low- and middle-income countries. Correlations of risk behaviors and demographic factors with prevalent STDs and the association of STDs with HIV prevalence are examined. Between 2,212 and 5,543 participants were recruited in each of five countries (China, India, Peru, Russia, and Zimbabwe). Standard protocols were used to collect behavioral risk information and biological samples for STD testing. Risk factors for HIV/STD prevalence were evaluated using logistic regression models. STD prevalence was significantly higher for women than men in all countries, and the most prevalent STD was Herpes simplex virus-type 2 (HSV-2). HIV prevalence was generally low (below 5%) except in Zimbabwe (30% among women, 11.7% among men). Prevalence of bacterial STDs was generally low (below 5% for gonorrhea and under 7% for syphilis in all sites), with the exception of syphilis among female sex workers in India. Behavioral and demographic risks for STDs varied widely across the five study sites. Common risks for STDs included female gender, increasing number of recent sex partners, and in some sites, older age, particularly for chronic STDs (i.e., HSV-2 and HIV). Prevalence of HIV was not associated with STDs except in Zimbabwe, which showed a modest correlation between HIV and HSV-2 prevalence (Pearson coefficient = .55). These findings underscore the heterogeneity of global STD and HIV epidemics and suggest that local, focused interventions are needed to achieve significant declines in these infections.
Pourahmadi, Mohammad Reza; Ebrahimi Takamjani, Ismail; Jaberzadeh, Shapour; Sarrafzadeh, Javad; Sanjari, Mohammad Ali; Bagheri, Rasool; Jannati, Elham
2018-06-01
Sit-to-stand (STD) and stand-to-sit (SIT) analysis can provide information on functional independence in daily activities in patients with low back pain (LBP). However, in order for measurements to be clinically useful, data on psychometric properties should be available. The main purpose was to investigate intra-rater reliability of STD and SIT tasks in participants with and without chronic non-specific LBP (CNLBP). The second purpose was to detect any differences in lumbar spine and hips sagittal plane kinematics and coordination between asymptomatic individuals and CNLBP patients during STD and SIT. Cross-sectional study. Twenty-three CNLBP patients and 23 demographically-matched controls were recruited. Ten markers were placed on specific anatomical landmarks. Participants were asked to perform STD and SIT at a preferred speed. Peak flexion angles, mean angular velocities, lumbar to hip movement ratios, and relative phase angles were measured. The procedure was repeated after 2 h and 6-8 days. Differences between two groups were analyzed using independent t-test. Intraclass correlation coefficient (ICC 3,k), standard error of measurement (SEM), and limits of agreement (LOAs) were also estimated. The ICC values showed moderate to excellent intra-rater reliability, with relatively low SEM values (≤10.17°). The 95% LOAs demonstrated that there were no differences between the measured parameters. Furthermore, CNLBP patients had limited sagittal plane angles, smaller angular velocities, and lumbar-hip dis-coordination compared to asymptomatic participants. The results indicated moderate to excellent test-retest reliability of STD and SIT analysis. Moreover, CNLBP patients had altered kinematics during STD and its reverse. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hanna, Melisha G.; Becker-Cohen, Rachel; Langman, Craig B.
2010-01-01
Background and observations: The current denominator for dosing dialysis is the urea distribution volume (V). Normalizing Kt/V to body surface area (S) has been proposed, but the implications of doing this in children have not been examined. Design, setting, participants, & measurements: Dialysis dose given to children and adolescents was calculated in terms of conventional V-based scaling and surface-area-normalized standard Kt/V (SAN-stdKt/V) calculated as stdKt/V·(Vant/S)/17.5, where Vant was an anthropometric estimate of V calculated using the Morgenstern equation. Formal 2-pool modeling was used to compute all dialysis adequacy outputs. Results: In 34 children (11 girls, 23 boys) dialyzed 3 times a week, age range 1.4 to 18 years, the mean delivered equilibrated Kt/V (eKt/V) was 1.40, and the mean stdKt/V was 2.49, both of which tended to be higher in younger children. The ratio of Vant to S was 15.6 ± 2.69 and was strongly associated with age between ages 2 and 16. SAN-stdKt/V averaged 2.21 and was strongly correlated with age between ages 2 and 16. If one considers a desired target for SAN-stdKt/V to be 2.45, all children less than 10 years of age were below target, despite having relatively high values of eKt/V and stdKt/V. Conclusions: If a surface-area-based denominator were to be adopted for dialysis dosing, most children under 10 years of age would receive markedly less dialysis than adolescent patients and would require 6- to 8-hour hemodialysis sessions or, for the youngest children, treatments given more frequently than 3 times/wk. PMID:20299373
Daugirdas, John T; Hanna, Melisha G; Becker-Cohen, Rachel; Langman, Craig B
2010-05-01
BACKGROUND AND OBSERVATIONS: The current denominator for dosing dialysis is the urea distribution volume (V). Normalizing Kt/V to body surface area (S) has been proposed, but the implications of doing this in children have not been examined. Dialysis dose given to children and adolescents was calculated in terms of conventional V-based scaling and surface-area-normalized standard Kt/V (SAN-stdKt/V) calculated as stdKt/V x (Vant/S)/17.5, where Vant was an anthropometric estimate of V calculated using the Morgenstern equation. Formal 2-pool modeling was used to compute all dialysis adequacy outputs. In 34 children (11 girls, 23 boys) dialyzed 3 times a week, age range 1.4 to 18 years, the mean delivered equilibrated Kt/V (eKt/V) was 1.40, and the mean stdKt/V was 2.49, both of which tended to be higher in younger children. The ratio of Vant to S was 15.6 +/- 2.69 and was strongly associated with age between ages 2 and 16. SAN-stdKt/V averaged 2.21 and was strongly correlated with age between ages 2 and 16. If one considers a desired target for SAN-stdKt/V to be 2.45, all children less than 10 years of age were below target, despite having relatively high values of eKt/V and stdKt/V. If a surface-area-based denominator were to be adopted for dialysis dosing, most children under 10 years of age would receive markedly less dialysis than adolescent patients and would require 6- to 8-hour hemodialysis sessions or, for the youngest children, treatments given more frequently than 3 times/wk.
Net Weight Issue LLNL DOE-STD-3013 Containers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilk, P
2008-01-16
The following position paper will describe DOE-STD-3013 container sets No.L000072 and No.L000076, and how they are compliant with DOE-STD-3013-2004. All masses of accountable nuclear materials are measured on LLNL certified balances maintained under an MC&A Program approved by DOE/NNSA LSO. All accountability balances are recalibrated annually and checked to be within calibration on each day that the balance is used for accountability purposes. A statistical analysis of the historical calibration checks from the last seven years indicates that the full-range Limit of Error (LoE, 95% confidence level) for the balance used to measure the mass of the contents of themore » above indicated 3013 containers is 0.185 g. If this error envelope, at the 95% confidence level, were to be used to generate an upper-limit to the measured weight of the containers No.L000072 and No.L000076, the error-envelope would extend beyond the 5.0 kg 3013-standard limit on the package contents by less than 0.3 g. However, this is still well within the intended safety bounds of DOE-STD-3013-2004.« less
30 CFR 75.1719-2 - Lighting fixtures; requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972... the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros...
30 CFR 75.1719-2 - Lighting fixtures; requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972... the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros...
30 CFR 75.1719-2 - Lighting fixtures; requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972... the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros...
30 CFR 75.1719-2 - Lighting fixtures; requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972... the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros...
30 CFR 75.1719-2 - Lighting fixtures; requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std. 32-1972... the Institute of Electrical and Electronics Engineers, Inc., Publications Office, 10662 Los Vaqueros...
Cunningham, Shayna D; Kerrigan, Deanna L; Jennings, Jacky M; Ellen, Jonathan M
2009-12-01
Important barriers to STD testing may include individuals' perceptions of STD-related stigma (negative societal attitudes toward STD infection) and expectations of STD-related shame (negative personal feelings) that would result from a positive STD test. Obtaining a clear understanding of the relationship between STD-related stigma, STD-related shame and STD testing may help inform programs and policies aimed at reducing STD transmission. Measures derived from previously published scales were used to assess perceived STD-related stigma, anticipated STD-related shame and receipt of an STD test in the past year in an urban, household sample of 594 sexually active 15-24-year-olds interviewed in 2004-2007. Logistic regression was used to examine associations between recent STD testing and perceived stigma, shame and other participant characteristics. Thirty-seven percent of males and 70% of females reporting having had an STD test in the past year; the largest proportions of tests (42% among males and 59% among females) had occurred in the context of a routine health care visit, not because adolescents had had disease symptoms or were concerned about exposure to infection. For both males and females, the level of STD-related stigma was negatively associated with the odds of having been tested (odds ratio, 0.5 for each). STD-related shame was not related to STD testing. Adolescents who view STDs as stigmatizing have a reduced likelihood of being screened, but it is unclear whether this relationship reflects their care seeking or providers' practice of offering STD screening at a routine health visit.
Andoh, J; Ferreira, M; Leppert, I R; Matsushita, R; Pike, B; Zatorre, R J
2017-02-15
Resting-state fMRI studies have become very important in cognitive neuroscience because they are able to identify BOLD fluctuations in brain circuits involved in motor, cognitive, or perceptual processes without the use of an explicit task. Such approaches have been fruitful when applied to various disordered populations, or to children or the elderly. However, insufficient attention has been paid to the consequences of the loud acoustic scanner noise associated with conventional fMRI acquisition, which could be an important confounding factor affecting auditory and/or cognitive networks in resting-state fMRI. Several approaches have been developed to mitigate the effects of acoustic noise on fMRI signals, including sparse sampling protocols and interleaved silent steady state (ISSS) acquisition methods, the latter being used only for task-based fMRI. Here, we developed an ISSS protocol for resting-state fMRI (rs-ISSS) consisting of rapid acquisition of a set of echo planar imaging volumes following each silent period, during which the steady state longitudinal magnetization was maintained with a train of relatively silent slice-selective excitation pulses. We evaluated the test-retest reliability of intensity and spatial extent of connectivity networks of fMRI BOLD signal across three different days for rs-ISSS and compared it with a standard resting-state fMRI (rs-STD). We also compared the strength and distribution of connectivity networks between rs-ISSS and rs-STD. We found that both rs-ISSS and rs-STD showed high reproducibility of fMRI signal across days. In addition, rs-ISSS showed a more robust pattern of functional connectivity within the somatosensory and motor networks, as well as an auditory network compared with rs-STD. An increased connectivity between the default mode network and the language network and with the anterior cingulate cortex (ACC) network was also found for rs-ISSS compared with rs-STD. Finally, region of interest analysis showed higher interhemispheric connectivity in Heschl's gyri in rs-ISSS compared with rs-STD, with lower variability across days. The present findings suggest that rs-ISSS may be advantageous for detecting network connectivity in a less noisy environment, and that resting-state studies carried out with standard scanning protocols should consider the potential effects of loud noise on the measured networks. Copyright © 2017 Elsevier Inc. All rights reserved.
Toward the MIL-STD and MIL-HDBK for Project Support Environment Interfaces
1992-11-01
acquisition and budget process in the past has taken a long time to field new standard computers, so long that the produced technology is often old...compared to commercial technology . The obvious logistics benefits associated with standard hardware are offset by the inability to field current... technology area. The Standard and Handbook Writing Team is tasked with actually writing the draft military standard and handbook. 3. PSESWG STANDARD The
Neural-Network Approach to Hyperspectral Data Analysis for Volcanic Ash Clouds Monitoring
NASA Astrophysics Data System (ADS)
Piscini, Alessandro; Ventress, Lucy; Carboni, Elisa; Grainger, Roy Gordon; Del Frate, Fabio
2015-11-01
In this study three artificial neural networks (ANN) were implemented in order to emulate a retrieval model and to estimate the ash Aerosol optical Depth (AOD), particle effective radius (reff) and cloud height from volcanic eruption using hyperspectral remotely sensed data. ANNs were trained using a selection of Infrared Atmospheric Sounding Interferometer (IASI) channels in Thermal Infrared (TIR) as inputs, and the corresponding ash parameters retrieved obtained using the Oxford retrievals as target outputs. The retrieval is demonstrated for the eruption of the Eyjafjallajo ̈kull volcano (Iceland) occurred in 2010. The results of validation provided root mean square error (RMSE) values between neural network outputs and targets lower than standard deviation (STD) of corresponding target outputs, therefore demonstrating the feasibility to estimate volcanic ash parameters using an ANN approach, and its importance in near real time monitoring activities, owing to its fast application. A high accuracy has been achieved for reff and cloud height estimation, while a decreasing in accuracy was obtained when applying the NN approach for AOD estimation, in particular for those values not well characterized during NN training phase.
The surface latent heat flux anomalies related to major earthquake
NASA Astrophysics Data System (ADS)
Jing, Feng; Shen, Xuhui; Kang, Chunli; Xiong, Pan; Hong, Shunying
2011-12-01
SLHF (Surface Latent Heat Flux) is an atmospheric parameter, which can describe the heat released by phase changes and dependent on meteorological parameters such as surface temperature, relative humidity, wind speed etc. There is a sharp difference between the ocean surface and the land surface. Recently, many studies related to the SLHF anomalies prior to earthquakes have been developed. It has been shown that the energy exchange enhanced between coastal surface and atmosphere prior to earthquakes can increase the rate of the water-heat exchange, which will lead to an obviously increases in SLHF. In this paper, two earthquakes in 2010 (Haiti earthquake and southwest of Sumatra in Indonesia earthquake) have been analyzed using SLHF data by STD (standard deviation) threshold method. It is shows that the SLHF anomaly may occur in interpolate earthquakes or intraplate earthquakes and coastal earthquakes or island earthquakes. And the SLHF anomalies usually appear 5-6 days prior to an earthquake, then disappear quickly after the event. The process of anomaly evolution to a certain extent reflects a dynamic energy change process about earthquake preparation, that is, weak-strong-weak-disappeared.
Clouds and troughs of total electron content detected with the ionospheric weather index
NASA Astrophysics Data System (ADS)
Gulyaeva, Tamara
2016-07-01
The ionospheric weather W index has been developed with the different thresholds of change in the F2 layer peak electron density NmF2 (proportional to foF2 critical frequency) or total electron content TEC relative their quiet reference for quantifying the ionosphere variability. The thresholds of DTEC=log(TEC/TECq) are selected for the positive and negative logarithm of TEC ratio to the quiet reference median, TECq, at any given location on the Earth. The global W-index maps are produced from Global Ionospheric Maps of Total Electron Content, GIM-TEC, and provided online at http://www.izmiran.ru/services/iweather/ and http://www.iololab.org/. Based on W-index maps, Catalogues of the ionospheric storms and sub-storms are produced available for the users. The second generation of the ionospheric weather indices, designated V index, is recently introduced and applied for the retrospective study of GIM-TEC variability during 1999-2015. Using sliding-window statistical analysis, moving daily-hourly TEC median TECq for 15 preceding days with estimated variance bounds are obtained at cells of GIM-TEC. The ionosphere variability index, V, is expressed in terms of ΔTEC deviation from the median normalized by the standard deviation STD. V index segmentation is introduced from Vn=-4 in step of 1 to Vp=4 specifying TEC storm if an instant TEC is outside of TECq+-1STD. The global maps of V index allow distinguish the clouds of enhanced TEC (positive storm signatures) and troughs of TEC depletion (negative storm signatures) as compared to the background quiet reference TECq map. It is found that the large-scale TEC clouds and troughs are observed in space all over the world constituting up to 20-50 percent of cells of GIM-TEC. The time variation of these plasma patches is partly following to geomagnetic SSC storm onset. As concerns the interplanetary and the solar wind, SW, sources of the ionospheric storms the TEC storms are observed both with IMF and SW precursors and without the IMF and SW storm signatures. Results of the ionospheric storm studies with the ionospheric weather indices are discussed in the paper. This study is supported by TUBITAK EEEAG 115E915.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-27
... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EE-2006-BT-STD-0129] RIN 1904-AA90 Energy Conservation Program: Energy Conservation Standards for Residential Water Heaters, Direct Heating Equipment, and Pool Heaters Correction In rule document 2010-7611 beginning on page 20112 in the issue of Friday...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
... EERE-2010-BT-STD-0048] RIN 1904-AC04 Energy Efficiency Standards for Distribution Transformers; Notice...-type distribution transformers. The purpose of the subcommittee will be to discuss and, if possible, reach consensus on a proposed rule for the energy efficiency of distribution transformers, as authorized...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-03
.... EERE-2010-BT-STD-0011] RIN 1904-AC22 Energy Efficiency Program: Energy Conservation Standards Furnace Fans: Public Meeting and Availability of the Framework Document AGENCY: Office of Energy Efficiency and... Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies, EE-2J, 1000 Independence...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... DEPARTMENT OF ENERGY 10 CFR Parts 429 and 430 [Docket Number EERE-2008-BT-STD-0019] RIN 1904-AB90 Energy Conservation Program: Energy Conservation Standards for Residential Clothes Washers AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Notice of effective date and...
40 CFR 60.332 - Standard for nitrogen oxides.
Code of Federal Regulations, 2012 CFR
2012-07-01
... from paragraph (a) of this section. (f) Stationary gas turbines using water or steam injection for... Turbines § 60.332 Standard for nitrogen oxides. (a) On and after the date on which the performance test... stationary gas turbine, any gases which contain nitrogen oxides in excess of: EC16NO91.020 where: STD...
40 CFR 60.332 - Standard for nitrogen oxides.
Code of Federal Regulations, 2014 CFR
2014-07-01
... from paragraph (a) of this section. (f) Stationary gas turbines using water or steam injection for... Turbines § 60.332 Standard for nitrogen oxides. (a) On and after the date on which the performance test... stationary gas turbine, any gases which contain nitrogen oxides in excess of: EC16NO91.020 where: STD...
40 CFR 60.332 - Standard for nitrogen oxides.
Code of Federal Regulations, 2011 CFR
2011-07-01
... from paragraph (a) of this section. (f) Stationary gas turbines using water or steam injection for... Turbines § 60.332 Standard for nitrogen oxides. (a) On and after the date on which the performance test... stationary gas turbine, any gases which contain nitrogen oxides in excess of: EC16NO91.020 where: STD...
40 CFR 60.332 - Standard for nitrogen oxides.
Code of Federal Regulations, 2010 CFR
2010-07-01
... from paragraph (a) of this section. (f) Stationary gas turbines using water or steam injection for... Turbines § 60.332 Standard for nitrogen oxides. (a) On and after the date on which the performance test... stationary gas turbine, any gases which contain nitrogen oxides in excess of: EC16NO91.020 where: STD...
40 CFR 60.332 - Standard for nitrogen oxides.
Code of Federal Regulations, 2013 CFR
2013-07-01
... from paragraph (a) of this section. (f) Stationary gas turbines using water or steam injection for... Turbines § 60.332 Standard for nitrogen oxides. (a) On and after the date on which the performance test... stationary gas turbine, any gases which contain nitrogen oxides in excess of: EC16NO91.020 where: STD...
Implementation of Ada protocols on Mil-STD-1553 B data bus
NASA Technical Reports Server (NTRS)
Ruhman, Smil; Rosemberg, Flavia
1986-01-01
Standardization activity of data communication in avionic systems started in 1968 for the purpose of total system integration and the elimination of heavy wire bundles carrying signals between various subassemblies. The growing complexity of avionic systems is straining the capabilities of MIL-STD-1553 B (first issued in 1973), but a much greater challenge to it is posed by Ada, the standard language adopted for real-time, computer embedded-systems. Hardware implementation of Ada communication protocols in a contention/token bus or token ring network is proposed. However, during the transition period when the current command/response multiplex data bus is still flourishing and the development environment for distributed multi-computer Ada systems is as yet lacking, a temporary accomodation of the standard language with the standard bus could be very useful and even highly desirable. By concentrating all status informtion and decisions at the bus controller, it was found to be possible to construct an elegant and efficient harware impelementation of the Ada protocols at the bus interface. This solution is discussed.
DOE standard 3009 - a reasoned, practical approach to integrating criticality safety into SARs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vessard, S.G.
1995-12-31
In the past there have been efforts by the U.S. Department of Energy (DOE) to provide guidance on those elements that should be included in a facility`s safety analysis report (SAR). In particular, there are two DOE Orders (5480.23, {open_quotes}Nuclear Safety Analysis Reports,{close_quotes} and 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), an interpretive guidance document (NE-70, Interpretive Guidance for DOE Order 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), and DOE Standard DOE-STD-3009-94 {open_quotes}Preparation Guide for U.S. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports.{close_quotes} Of these, the most practical and useful (pertaining to the application of criticality safety) is DOE-STD-3009-94. This paper is a reviewmore » of Chapters 3, 4, and 6 of this standard and how they provide very clear, helpful, and reasoned criticality safety guidance.« less
Collaborative Radiological Response Planning
2013-12-01
280-5500 Standard Form 298 (Rev. 2–89) Prescribed by ANSI Std. 239–18 i THIS PAGE INTENTIONALLY LEFT BLANK ii Approved for public release...critical tasks, under specified conditions and performance standards .”33 Aligned with the central objective of Capabilities-Based Planning, the TCL...affect task performance.36 More specifically, measures and performance criteria describe a standard for how well a task must be performed and on
Alternate Care Sites for the Management of Medical Surge in Disasters
2013-12-01
CLASSIFICATION OF ABSTRACT Unclassified 20. LIMITATION OF ABSTRACT UU NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std...Figure 1. Hierarchy of Requests (From California Department of Public Health Standards and Guidelines for Healthcare Surge during Emergencies Hospital...requirements, financial, risk management and safety reasons and others for the performance standards that are achieved through the accreditation
López-Garrido, Javier; Casadesús, Josep
2012-01-01
Invasion of intestinal epithelial cells is a critical step in Salmonella infection and requires the expression of genes located in Salmonella pathogenicity island 1 (SPI-1). A key factor for SPI-1 expression is DNA adenine (Dam) methylation, which activates synthesis of the SPI-1 transcriptional activator HilD. Dam-dependent regulation of hilD is postranscriptional (and therefore indirect), indicating the involvement of unknown cell functions under Dam methylation control. A genetic screen has identified the std fimbrial operon as the missing link between Dam methylation and SPI-1. We show that all genes in the std operon are part of a single transcriptional unit, and describe three previously uncharacterized ORFs (renamed stdD, stdE, and stdF). We present evidence that two such loci (stdE and stdF) are involved in Dam-dependent control of Salmonella SPI-1: in a Dam(-) background, deletion of stdE or stdF suppresses SPI-1 repression; in a Dam(+) background, constitutive expression of StdE and/or StdF represses SPI-1. Repression of SPI-1 by products of std operon explains the invasion defect of Salmonella Dam(-) mutants, which constitutively express the std operon. Dam-dependent repression of std in the ileum may be required to permit invasion, as indicated by two observations: constitutive expression of StdE and StdF reduces invasion of epithelial cells in vitro (1,000 fold) and attenuates Salmonella virulence in the mouse model (>60 fold). In turn, crosstalk between std and SPI-1 may play a role in intestinal infections by preventing expression of SPI-1 in the caecum, an intestinal compartment in which the std operon is known to be expressed.
[Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].
Zhou, Xia; Wu, Wenli; Bao, Shudi
2015-07-01
IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.
NASA Astrophysics Data System (ADS)
Zhou, Feng; Li, Xingxing; Cai, Miaomiao; Chen, Wen; Dong, Danan; Schuh, Harald
2017-04-01
Since October 2011, the Russian GLONASS has been revitalized and is now fully operational with 24 satellites in orbit. It is critical to assess the benefits and problems of using GLONASS observations (i.e. GLONASS-only or combined GPS/GLONASS) for precise positioning and zenith total delay (ZTD) retrieval on a global scale using the precise point positioning (PPP) technique. In this contribution, extensive evaluations are conducted with GNSS data sets collected from 251 globally distributed stations of the International GNSS Service (IGS) network in July 2016. The stations are divided into 30 groups by antenna/radome types to investigate whether there are antenna/radome-dependent biases in position and ZTD results derived from GLONASS-only PPP. The positioning results do not show obvious antenna/radome-dependent biases except the stations with JAV_RINGANT_G3T/NONE. The averaged biases of the stations with JAV_RINGANT_G3T/NONE in horizontal component especially in north component can even achieve -9.0 mm. The standard deviation (STD) and root mean square (RMS) are used as indicators of positioning repeatability and accuracy, respectively. Compared with GPS-only PPP, smaller averaged STD and RMS values of GLONASS-only PPP are achieved in horizontal component, while larger ones in vertical component. Furthermore, the STD and RMS values of GPS/GLONASS combined PPP solutions are the smallest in horizontal and vertical components, indicating that adding GLONASS observations can achieve better positioning performance than GPS-only PPP. Meanwhile, better positioning repeatability and accuracy are found in north component than that in east component, which may be caused by the configuration of GNSS satellite orbit. With respect to GPS-only PPP-derived ZTD, the ZTD biases, accuracy, and correlation derived from GLONASS-only and GPS/GLONASS PPP solutions are antenna/radome-independent, while the biases and accuracy are slightly latitude- or Geometric Dilution of Precisions (GDOP)-dependent, as well as the ZTD correlation are highly latitude- or GDOP-dependent. We also studied the impact of the chosen elevation cutoff angles on the positioning and ZTD retrieval. GLONASS-only PPP is found more sensitive with the elevation cutoff angles than GPS-only PPP.
Hofford, Rebecca S; Chow, Jonathan J; Beckmann, Joshua S; Bardo, Michael T
2017-12-01
Opioid abuse is a major problem around the world. Identifying environmental factors that contribute to opioid abuse and addiction is necessary for decreasing this epidemic. In rodents, environmental enrichment protects against the development of low dose stimulant self-administration, but studies examining the effect of enrichment and isolation (compared to standard housing) on the development of intravenous opioid self-administration have not been conducted. The present study investigated the role of environmental enrichment on self-administration of the short-acting μ-opioid remifentanil. Rats were raised in an enriched condition (Enr), standard condition (Std), or isolated condition (Iso) beginning at 21 days of age and were trained to lever press for 1 or 3 μg/kg/infusion remifentanil in young adulthood. Acquisition of self-administration and responding during increasing fixed ratio requirements were assessed, and a dose-response curve was generated. In all phases, Enr rats lever pressed significantly less than Std and Iso rats, with Enr rats pressing between 9 and 40% the amount of Iso rats. Enr rats did not acquire remifentanil self-administration when trained with 1 μg/kg/infusion, did not increase responding over increasing FR when trained at either dose, and their dose-response curves were flattened compared to Std and Iso rats. When expressed as economic demand curves, Enr rats displayed a decrease in both essential value (higher α) and reinforcer intensity (Q 0 ) compared to Std and Iso rats at the 1 μg/kg/infusion training dose. Environmental enrichment reduced remifentanil intake, suggesting that social and environmental novelty may protect against opioid abuse.
10 CFR 431.133 - Materials incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
.... Fairfax Dr., Suite 200, Arlington, VA 22203 or http://www.ari.org/std/standards.htm. (ii) Anyone can..., Atlanta, GA 30329, (404) 636-8400, or http://www.ashrae.org. [71 FR 71372, Dec. 8, 2006] ...
In defense of the classical height system
NASA Astrophysics Data System (ADS)
Foroughi, Ismael; Vaníček, Petr; Sheng, Michael; Kingdon, Robert William; Santos, Marcelo C.
2017-11-01
In many European countries, normal heights referred to the quasi-geoid as introduced by Molodenskij in the mid-20th century are preferred to the classical height system that consists of orthometric heights and the geoid as a reference surface for these heights. The rationale for this choice is supposed to be that in the classical height system, neither the geoid, nor the orthometric height can be ever known with centimetre level accuracy because one would need to know the topographical mass density to a level that can never be achieved. The aim of this paper is to question the validity of this rationale. The common way of assessing the congruency of a local geoid model and the orthometric heights is to compare the geoid heights with the difference between orthometric heights provided by leveling and geodetic heights provided by GNSS. On the other hand, testing the congruency of a quasi-geoidal model with normal height a similar procedure is used, except that instead of orthometric heights, normal heights are employed. For the area of Auvergne, France, which is now a more or less standard choice for precise geoid or quasi-geoid testing, only the normal heights are supplied by the Institute Geographic National, the provider of the data. This is clearly the consequence of the European preference for the Molodenskij system. The quality of the height system is to be judged by the congruency of the difference of the geoid/quasi-geoid heights subtracted from the geodetic heights and orthometric/normal heights. To assess the congruency of the classical height system, the Helmert approximation of orthometric heights is typically used as the transformation between normal and Helmert's heights is easily done. However, the evaluation of the differences between Helmert's and the rigorous orthometric heights is somewhat more involved as will be seen from the review in this paper. For the area of interest, the differences between normal and Helmert's heights at the control leveling points range between - 9.5 and 0 cm, differences between Helmert's and the rigorous orthometric heights vary between - 3.6 and 1.1 cm. The local gravimetric geoid model of Auvergne, computed by the Stokes-Helmert technique, is used here to illustrate the accuracy of the classical height system. Results show a very reasonable standard deviation (STD) of 3.2 cm of the differences between geoid values, derived from control leveling points, and gravimetric geoid heights when Helmert's heights are employed and even a smaller STD of 2.9 cm when rigorous orthometric heights are used. A corresponding comparison of a quasi-geoid model, computed by Least-Squares Modification of Stokes method, with normal heights show an STD of 3.4 cm.
Fully automated processing of buffy-coat-derived pooled platelet concentrates.
Janetzko, Karin; Klüter, Harald; van Waeg, Geert; Eichler, Hermann
2004-07-01
The OrbiSac device, which was developed to automate the manufacture of buffy-coat PLT concentrates (BC-PCs), was evaluated. In-vitro characteristics of BC-PC preparations using the OrbiSac device were compared with manually prepared BC-PCs. For standard processing (Std-PC, n = 20), four BC-PCs were pooled using 300 mL of PLT AS (PAS) followed by soft-spin centrifugation and WBC filtration. The OrbiSac preparation (OS-PC, n = 20) was performed by automated pooling of four BC-PCs with 300 mL PAS followed by centrifugation and inline WBC filtration. All PCs were stored at 22 degrees C. Samples were withdrawn on Day 1, 5, and 7 evaluating PTL count, blood gas analysis, glucose, lactate, LDH, beta-thromboglobulin, hypotonic shock response, and CD62p expression. A PLT content of 3.1 +/- 0.4 x 10(11) (OS-PCs) versus 2.7 +/- 0.5 x 10(11) (Std-PCs, p < 0.05) was found. A CV of 19 percent (Std-PC) versus 14 percent (OS-PC) suggests more standardization in the OS group. At Day 7, the Std-PCs versus OS-PCs showed a glucose consumption of 1.03 +/- 0.32 micro mol per 10(9) PLT versus 0.75 +/- 0.25 micro mol per 10(9) PLT (p < 0.001), and a lactate production of 1.50 +/- 0.86 micro mol per 10(9) versus 1.11 +/- 0.61 micro mol per 10(9) (p < 0.001). The pH (7.00 +/- 0.19 vs. 7.23 +/- 0.06; p < 0.001), pO(2) (45.3 +/- 18 vs. 31.3 +/- 10.4 mmHg; p < 0.01), and HCO(3) levels (4.91 +/- 1.49 vs. 7.14 +/- 0.95 mmol/L; p < 0.001) suggest a slightly better aerobic metabolism within the OS group. Only small differences in CD62p expression was observed (37.3 +/- 12.9% Std-PC vs. 44.8 +/- 6.6% OS-PC; p < 0.05). The OrbiSac device allows an improved PLT yield without affecting PLT in-vitro characteristics and may enable an improved consistency in product volume and yield.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-09
... Management. The life-cycle cost guidance and required discount rates and energy price projections are... Supplement to The National Institute of Standards and Technology Handbook 135: ``Energy Price Indices and... DEPARTMENT OF ENERGY 10 CFR Part 433 [Docket No. EERE-2011-BT-STD-0055] RIN 1904-AC60 Energy...
76 FR 23470 - Version One Regional Reliability Standard for Transmission Operations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-27
... (BPA), WECC, and San Diego Gas & Electric Company (SDG&E). II. Discussion 16. The Commission approves... unknown operating state. 23. Similarly, BPA states that it is unnecessary to carry over from TOP-STD-007-0... as TOP-004-2. BPA also notes that the continent-wide Reliability Standard, TOP-007-0, does not...
System and Network Security Acronyms and Abbreviations
2009-09-01
hazards of electromagnetic radiation to fuel HERO hazards of electromagnetic radiation to ordnance HERP hazards of electromagnetic ...ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 System and Network Security Acronyms...authentication and key management ALG application layer gateway ANSI American National Standards Institute AP access point API application
Teerawattanapong, Nattawat; Kengkla, Kirati; Dilokthornsakul, Piyameth; Saokaew, Surasak; Apisarnthanarak, Anucha; Chaiyakunapruk, Nathorn
2017-05-15
This study evaluated the relative efficacy of strategies for the prevention of multidrug-resistant gram-negative bacteria (MDR-GNB) in adult intensive care units (ICUs). A systematic review and network meta-analysis was performed; searches of the Cochrane Library, PubMed, Embase, and CINAHL (Cumulative Index to Nursing and Allied Health Literature) included all randomized controlled trials and observational studies conducted in adult patients hospitalized in ICUs and evaluating standard care (STD), antimicrobial stewardship program (ASP), environmental cleaning (ENV), decolonization methods (DCL), or source control (SCT), simultaneously. The primary outcomes were MDR-GNB acquisition, colonization, and infection; secondary outcome was ICU mortality. Of 3805 publications retrieved, 42 met inclusion criteria (5 randomized controlled trials and 37 observational studies), involving 62068 patients (median age, 58.8 years; median APACHE [Acute Physiology and Chronic Health Evaluation] II score, 18.9). The majority of studies reported extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae and MDR Acinetobacter baumannii. Compared with STD, a 4-component strategy composed of STD, ASP, ENV, and SCT was the most effective intervention (rate ratio [RR], 0.05 [95% confidence interval {CI}, .01-.38]). When ENV was added to STD+ASP or SCT was added to STD+ENV, there was a significant reduction in the acquisition of MDR A. baumannii (RR, 0.28 [95% CI, .18-.43] and 0.48 [95% CI, .35-.66], respectively). Strategies with ASP as a core component showed a statistically significant reduction the acquisition of ESBL-producing Enterobacteriaceae (RR, 0.28 [95% CI, .11-.69] for STD+ASP+ENV and 0.23 [95% CI, .07-.80] for STD+ASP+DCL). A 4-component strategy was the most effective intervention to prevent MDR-GNB acquisition. As some strategies were differential for certain bacteria, our study highlighted the need for further evaluation of the most effective prevention strategies. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail: journals.permissions@oup.com.
Another Look at the Draft Mil-Std-1540E Unit Random Vibration Test Requirements
NASA Astrophysics Data System (ADS)
Perl, E.; Peterson, A. J..; Davis, D.
2012-07-01
The draft Mil-Std-1540E has been updated to reflect lessons learned since its publication as an SMC Standard in 2008, [1], and an earlier Aerospace Corporation Technical Report released in 2006, [2]. This paper discusses the technical rationale supporting some of the unit random vibration test requirements to provide better insight into their derivation and application to programs. It is intended that these requirements be tailored for each program to reflect the customer risk profile. Several tailoring options are provided and a two phase test strategy is discussed to highlight its applicability to utilizing heritage hardware in new applications.
1989-09-01
STD-2167A by William T. Livings September 1989 Thesis Advisor: Barry A. Frew Approved for public release; distribution is unlimited UNCLASSIFIED...f’P) TfLI Po*i~o1 (InoriudC A,.’-g IOle) *’, i 14 41 iProf.- Barry A. Frow (Q11rioqAr. DD Form 1 413, JUN 86 ’Ciij ’iI ’ ti)P ,i I. ij j-~-~I i~4~~6...easily changed or corrected when errors are found; and programs that are delivered for use months or even years too late. ( Pressman , 1988, pp. I- 2
33 CFR 154.2020 - Certification and recertification-owner/operator responsibilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Procedures,” and in Military Standard MIL-STD-882B for a quantitative failure analysis. For assistance in... quantitative failure analysis is also conducted, the level of safety attained is at least one order of...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
.... EERE-2013-BT-STD-0022] RIN 1904-AD00 Energy Efficiency Program for Commercial and Industrial Equipment... the Framework Document pertaining to the development of energy conservation standards for refrigerated...
40 CFR 1033.705 - Calculating emission credits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... applicable NOX or PM emission standard in g/bhp-hr (except that Std = previous FEL in g/bhp-hr for... life). FEL = the family emission limit for the engine family in g/bhp-hr. UL = the sales-weighted...
40 CFR 1033.705 - Calculating emission credits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... applicable NOX or PM emission standard in g/bhp-hr (except that Std = previous FEL in g/bhp-hr for... life). FEL = the family emission limit for the engine family in g/bhp-hr. UL = the sales-weighted...
Military applications of emission and susceptibility data
NASA Astrophysics Data System (ADS)
Kohlbacher, Howard; Walker, William
A basic design consideration for new military communications-electronics (C-E) equipment is that it be electromagnetically compatible with the environment in which it will operate. A military standard (MIL-STD-461B) describes the design requirements for the control of the unintentional electromagnetic emission and susceptibility characteristics of electronic equipment and subsystems designed or procured by the US Department of Defense. For new systems which fail the test standards of MIL-STD-461B with regard to radiated susceptibility (RSO3) or radiated emissions (RE02), a decision must be made to fix the new system or to field it without a fix. A procedure to aid in the decision process is outlined. The minimum separation distances required between a failed test system and other C-E equipment in its environment to avoid interference are determined. If this distance is operationally acceptable, the failed unit may be considered to be operationally compatible with its electromagnetic environment.
Operations and Plans: International Military Rationalization, Standardization, and Interoperability
1989-02-15
Army Regulation 34–1 Operations and Plans International Military Rationalization , Standardization, and Interoperability Headquarters Department of...YYYY) 15-02-1997 2. REPORT TYPE 3. DATES COVERED (FROM - TO) xx-xx-1997 to xx-xx-1997 4. TITLE AND SUBTITLE International Military Rationalization ...DSN 427-9007 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39.18 SUMMARY of CHANGE AR 34–1 International Military Rationalization
Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide
NASA Technical Reports Server (NTRS)
Wheeler, M. L.
1998-01-01
The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.
Sexual dimorphism of the suprascapular notch – morphometric study
Jędrzejewski, Kazimierz S.; Topol, Mirosław
2013-01-01
Introduction The concept of the study was to compare the morphometry of the suprascapular notch (SSN) in females and males because its size and shape may be a factor in suprascapular nerve entrapment. Material and methods The measurements of 81 scapulae included morphological length and width, maximal width and length projection of the scapular spine, and width and length of the glenoid cavity. The width-length scapular and glenoid cavity indices were calculated. In addition to standard anthropometric measurements three other dimensions were defined and collected for every SSN: maximal depth (MD), superior (STD) and middle (MTD) transverse diameters. Results The analysis of the measurements allowed us to distinguish five types of SSN. Type I (26%) had longer maximal depth than superior transverse diameter. Type II (3%) had equal MD, STD and MTD. In type III (57.6%) superior transverse diameter was longer than maximal depth. In type IV (7.4%) a bony foramen was present. Type V (6%) was without a discrete notch. Types I and III were divided into two subtypes: A (MTD was longer than STD) and B (MTD < STD). Distribution of the suprascapular notch types in both sexes was similar. However, MD, STD and MTD were significantly higher in males. The superior transverse suprascapular ligament was completely and partially ossified in 7.4% and 24.7% respectively. Conclusions The presented classification of the suprascapular notch is simple, easy to use, and based on specific geometric parameters which allow one to clearly distinguish five types of these structures. All dimensions of SSN were significantly higher in males than in females. PMID:23515320
Continuing Need for Sexually Transmitted Disease Clinics After the Affordable Care Act.
Hoover, Karen W; Parsell, Bradley W; Leichliter, Jami S; Habel, Melissa A; Tao, Guoyu; Pearson, William S; Gift, Thomas L
2015-11-01
We assessed the characteristics of sexually transmitted disease (STD) clinic patients, their reasons for seeking health services in STD clinics, and their access to health care in other venues. In 2013, we surveyed persons who used publicly funded STD clinics in 21 US cities with the highest STD morbidity. Of the 4364 STD clinic patients we surveyed, 58.5% were younger than 30 years, 72.5% were non-White, and 49.9% were uninsured. They visited the clinic for STD symptoms (18.9%), STD screening (33.8%), and HIV testing (13.6%). Patients chose STD clinics because of walk-in, same-day appointments (49.5%), low cost (23.9%), and expert care (8.3%). Among STD clinic patients, 60.4% had access to another type of venue for sick care, and 58.5% had access to another type of venue for preventive care. Most insured patients (51.6%) were willing to use insurance to pay for care at the STD clinic. Despite access to other health care settings, patients chose STD clinics for sexual health care because of convenient, low-cost, and expert care. Policy Implication. STD clinics play an important role in STD prevention by offering walk-in care to uninsured patients.
Du, Ping; Thomas, Rosalind; McNutt, Louise-Anne; Bruce Coles, F
2008-01-01
To assess the feasibility and generalizability of STD clinic samples for studying STD-related knowledge, attitudes, and behaviors (KAB), and healthcare preferences among individuals at high risk for STDs in the same community. An STD clinic and a community sample were selected from each of two urban areas in New York State. At each STD clinic, 100 individuals were interviewed. In each community, about 400 individuals were selected by random-digit-dialing telephone survey during the same period. Community sample participants were defined as having high-risk profiles on the basis of five items related to their sexual behaviors. The STD clinic samples were younger and had a larger proportion of men and nonwhite people compared with the high-risk community samples. Although the majority of STD clinic clients would seek healthcare at the STD clinics, high-risk community participants were more likely to prefer private doctors for STDs care (P < .0001 for both areas). Overall STD-related KAB were similar between STD clinic and high-risk community samples; however, STD clinic clients may be more knowledgeable about specific STDs and more likely to feel embarrassment about getting an STD. The findings comparing KAB between high-risk community subjects and STD clinic attendees also varied by geographic location. STD clinic samples may not be sufficiently representative of community STD-related KAB collected by telephone surveys, even for that subset of community respondents with high-risk behaviors associated with STDs.
Jakomin, Marcello; Chessa, Daniela; Bäumler, Andreas J; Casadesús, Josep
2008-11-01
DNA adenine methylase (dam) mutants of Salmonella enterica serovar Typhimurium grown under laboratory conditions express the std fimbrial operon, which is tightly repressed in the wild type. Here, we show that uncontrolled production of Std fimbriae in S. enterica serovar Typhimurium dam mutants contributes to attenuation in mice, as indicated by the observation that an stdA dam strain is more competitive than a dam strain upon oral infection. Dam methylation appears to regulate std transcription, rather than std mRNA stability or turnover. A genetic screen for std regulators showed that the GATC-binding protein SeqA directly or indirectly represses std expression, while the poorly characterized yifA gene product serves as an std activator. YifA encodes a putative LysR-like protein and has been renamed HdfR, like its Escherichia coli homolog. Activation of std expression by HdfR is observed only in dam and seqA backgrounds. These data suggest that HdfR directly or indirectly activates std transcription. Since SeqA is unable to bind nonmethylated DNA, it is possible that std operon derepression in dam and seqA mutants may result from unconstrained HdfR-mediated activation of std transcription. Derepression of std in dam and seqA mutants of S. enterica occurs in only a fraction of the bacterial population, suggesting the occurrence of either bistable expression or phase variation.
DiClemente, R J; Wingood, G M; Crosby, R A; Sionean, C; Brown, L K; Rothbaum, B; Zimand, E; Cobb, B K; Harrington, K; Davies, S
2001-11-01
The purpose of the study was to examine the association between adolescents' psychological distress and their sexually transmitted disease/human immunodeficiency virus (STD/HIV)-associated sexual behaviors and attitudes. Sexually active black adolescent females (N = 522) completed, at baseline and again 6 months later, a self-administered questionnaire that assessed sexual health attitudes and emotional distress symptoms (using standardized measures, alpha =.84), a structured interview that assessed STD/HIV-associated sexual risk behaviors, and a urine screen for pregnancy. In multivariate analyses, controlling for observed covariates, adolescents with significant distress at baseline were more likely than their peers, after 6 months, to be pregnant (adjusted odds ratio [AOR]: = 2.0), have had unprotected vaginal sex (AOR = 2.1), have nonmonogamous sex partners (AOR = 1.7), and not use any form of contraception (AOR = 1.5). Additionally, they were also more likely to: perceive barriers to condom use (AOR = 2.2), be fearful of the adverse consequences of negotiating condom use (AOR = 2.0), perceive less control in their relationship (AOR = 2.0), have experienced dating violence (AOR = 2.4), feel less efficacious in negotiating condom use with a new sex partner (AOR = 1.6), and have norms nonsupportive of a healthy sexual relationship (AOR = 1.7). The findings suggest that psychological distress is predictive over a 6-month period of a spectrum of STD/HIV-associated sexual behaviors and high-risk attitudes. Brief screening to detect distress or depressive symptoms among adolescent females can alert the clinician to the need to conduct a sexual health history, initiate STD/HIV-preventive counseling, and refer for comprehensive psychological assessment and appropriate treatment. Among adolescents receiving STD treatment, those with even moderate emotional distress may be at heightened risk for further unhealthy outcomes. STD/HIV interventions should also consider psychological distress as one potential risk factor that may impact program efficacy.
Rating precast prestressed concrete bridges for shear
DOT National Transportation Integrated Search
2008-12-01
Shear capacity of real-world prestressed concrete girders designed in the 1960s and 1970s is a concern because : AASHTO Standard Specifications (AASHTO-STD) employed the quarter-point rule for shear design, which is less : conservative for shea...
Continuing Need for Sexually Transmitted Disease Clinics After the Affordable Care Act
Parsell, Bradley W.; Leichliter, Jami S.; Habel, Melissa A.; Tao, Guoyu; Pearson, William S.; Gift, Thomas L.
2015-01-01
Objectives. We assessed the characteristics of sexually transmitted disease (STD) clinic patients, their reasons for seeking health services in STD clinics, and their access to health care in other venues. Methods. In 2013, we surveyed persons who used publicly funded STD clinics in 21 US cities with the highest STD morbidity. Results. Of the 4364 STD clinic patients we surveyed, 58.5% were younger than 30 years, 72.5% were non-White, and 49.9% were uninsured. They visited the clinic for STD symptoms (18.9%), STD screening (33.8%), and HIV testing (13.6%). Patients chose STD clinics because of walk-in, same-day appointments (49.5%), low cost (23.9%), and expert care (8.3%). Among STD clinic patients, 60.4% had access to another type of venue for sick care, and 58.5% had access to another type of venue for preventive care. Most insured patients (51.6%) were willing to use insurance to pay for care at the STD clinic. Conclusions. Despite access to other health care settings, patients chose STD clinics for sexual health care because of convenient, low-cost, and expert care. Policy Implication. STD clinics play an important role in STD prevention by offering walk-in care to uninsured patients. PMID:26447908
Show me the money: state contributions toward STD prevention, 2007.
Meyerson, Beth E; Gilbert, Lisa K
2010-01-01
The importance of state investment in sexually transmitted disease (STD) prevention has been discussed since the mid-1990s; however, little has become known about state public health funding for STD prevention. To establish a baseline understanding of state STD prevention funding, financial data for fiscal year 2007 were gathered by survey of state STD, immunization, laboratory, and hepatitis program directors. Results revealed that on average states funded 25.8 percent of their total STD prevention budgets and invested $0.23 per capita in STD prevention. The percentage of state funding in the total state STD prevention budget ranged from 0 percent to 70.2 percent, and state investment in STD prevention ranged from $0.00 to $1.55 per capita. The direction and expenditure of state STD prevention resources was also examined. This study strengthens the national understanding of what states are doing to fund STD prevention, and it broadens state public health awareness of the overall STD prevention investment at the state level. The inclusion of Medicaid data and expenditure of federal resources by states would strengthen the study and assist longitudinal analyses focused on the impact of investment on epidemiologic indicators.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Low, M; Matthew02 Miller, M; Thomas Reilly, T
2007-04-30
Washington Safety Management Solutions (WSMS) provides criticality safety services to Washington Savannah River Company (WSRC) at the Savannah River Site. One activity at SRS is the Container Surveillance and Storage Capability (CSSC) Project, which will perform surveillances on 3013 containers (hereafter referred to as 3013s) to verify that they meet the Department of Energy (DOE) Standard (STD) 3013 for plutonium storage. The project will handle quantities of material that are greater than ANS/ANSI-8.1 single parameter mass limits, and thus required a Nuclear Criticality Safety Evaluation (NCSE). The WSMS methodology for conducting an NCSE is outlined in the WSMS methods manual.more » The WSMS methods manual currently follows the requirements of DOE-O-420.1B, DOE-STD-3007-2007, and the Washington Savannah River Company (WSRC) SCD-3 manual. DOE-STD-3007-2007 describes how a NCSE should be performed, while DOE-O-420.1B outlines the requirements for a Criticality Safety Program (CSP). The WSRC SCD-3 manual implements DOE requirements and ANS standards. NCSEs do not address the Nuclear Criticality Safety (NCS) of non-reactor nuclear facilities that may be affected by overt or covert activities of sabotage, espionage, terrorism or other security malevolence. Events which are beyond the Design Basis Accidents (DBAs) are outside the scope of a double contingency analysis.« less
Development and Evaluation of a Hyperbaric Toxic Gas Monitor (SubTox) for Disabled Submarines
2013-08-01
PAGES 19a. NAME OF RESPONSIBLE PERSON: NEDU Librarian a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified 19b. TELEPHONE...NUMBER (include area code) 850.230.3170 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 ii ACKNOWLEDGMENTS This work...in September 2012. iii CONTENTS Standard Form 298 ................................................................................ i
Development and Evaluation of a Hyperbaric Toxic Gas Monitor (SUBTOX) for Disabled Submarines
2013-08-01
PAGES 19a. NAME OF RESPONSIBLE PERSON: NEDU Librarian a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified 19b. TELEPHONE...NUMBER (include area code) 850.230.3170 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 ii ACKNOWLEDGMENTS This work...in September 2012. iii CONTENTS Standard Form 298 ................................................................................ i
USDA-ARS?s Scientific Manuscript database
Hamsters are often used to determine the effects of various dietary ingredients on the development of cardiovascular disease (CVD). The study was conducted to obtain baseline data on CVD risk factors and mRNA expression of selected genes in hamsters fed a standard maintenance diet (STD) for 24 wk, b...
1 Canadian Forces Flying Training School (1 CFFTS) Resource Allocation Simulation Tool
2011-12-01
unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Séguin 2 SCHOOL OPERATION 2.1 Resources The school uses the...consist of standard classroom lessons, simulator sessions or flights. Several of the activities require preparation for the instructor. This extra...different stage of completion. For each different course, there is a standard curriculum that consists of a series of daily activities to be performed
Iqbal, Abdullah; Valous, Nektarios A; Mendoza, Fernando; Sun, Da-Wen; Allen, Paul
2010-03-01
Images of three qualities of pre-sliced pork and Turkey hams were evaluated for colour and textural features to characterize and classify them, and to model the ham appearance grading and preference responses of a group of consumers. A total of 26 colour features and 40 textural features were extracted for analysis. Using Mahalanobis distance and feature inter-correlation analyses, two best colour [mean of S (saturation in HSV colour space), std. deviation of b*, which indicates blue to yellow in L*a*b* colour space] and three textural features [entropy of b*, contrast of H (hue of HSV colour space), entropy of R (red of RGB colour space)] for pork, and three colour (mean of R, mean of H, std. deviation of a*, which indicates green to red in L*a*b* colour space) and two textural features [contrast of B, contrast of L* (luminance or lightness in L*a*b* colour space)] for Turkey hams were selected as features with the highest discriminant power. High classification performances were reached for both types of hams (>99.5% for pork and >90.5% for Turkey) using the best selected features or combinations of them. In spite of the poor/fair agreement among ham consumers as determined by Kappa analysis (Kappa-value<0.4) for sensory grading (surface colour, colour uniformity, bitonality, texture appearance and acceptability), a dichotomous logistic regression model using the best image features was able to explain the variability of consumers' responses for all sensorial attributes with accuracies higher than 74.1% for pork hams and 83.3% for Turkey hams. Copyright 2009 Elsevier Ltd. All rights reserved.
Resistance Training Increases the Variability of Strength Test Scores
2009-06-08
standard deviations for pretest and posttest strength measurements. This information was recorded for every strength test used in a total of 377 samples...significant if the posttest standard deviation consistently was larger than the pretest standard deviation. This condition could be satisfied even if...the difference in the standard deviations was small. For example, the posttest standard deviation might be 1% larger than the pretest standard
Technical basis for inner container leak detection sensitivity goals in 3013 DE surveillance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berg, John M.
Helium leak checking of 3013 inner container lids is under consideration for addition to DE Surveillance tasks as an improved means to detect any through-wall flaws that may have formed during storage. This white paper evaluates whether leak checking at DE could replace and improve upon the current method of comparing gas compositions and pressures within the inner and outer containers. We have used viscous and molecular flow equations in ANSI N14.5 to calculate what the measured standard helium leak rate would be for hypothetical leaks of three different sizes. For comparison, we have also calculated the effects on gasmore » composition and pressure differences as a function of pre-DE storage time for the same three leak sizes, using molecular and viscous flow equations as well as diffusion equations to predict the relevant gas transport. For a hypothetical leak that would be measured at 1x10 -7 std cc/sec, likely an achievable sensitivity using helium leak checking at DE, the calculations predict no measurable effect on pressure difference or gas composition as measured by DE gas analysis. We also calculate that it would take over 200 years for water vapor to diffuse through a 10 -7 std cc/sec leak enough to raise the RH outer container to half the RH value in the inner container. A leak 100 times larger, which would be measured at 1x10 -5 std cc/sec, the same water vapor diffusion would take at least 14 years. Our conclusion is that helium leak checking will be useful even at a sensitivity of 1x10 -5 std cc/sec, and a significant improvement over current DE methods at a sensitivity of 1x10 -7 std cc/sec.« less
Chess, David; Lei, Biao; Hoit, Brian; Azimzadeh, Agnes M.; Stanley, William
2009-01-01
Background Dietary lipid content effects activation of peroxisome proliferator-activated receptor-α (PPARα) and may accelerate cardiac hypertrophy and dysfunction in response to pressure overload. This study investigated the effects of a high fat diet on the development of cardiac hypertrophy. Methods and Results C57BL/6J mice (n=14–16/group) underwent transverse aortic constriction (TAC) or sham surgery and were fed either standard low fat diet (STD; 10% fat) or a high fat diet (HFD; 60% fat) for 16 weeks. Sham mice showed no differences between STD and HFD for heart mass or echocardiographic parameters despite greater plasma free fatty acid and leptin concentrations with HFD. TAC increased heart mass and decreased ejection fraction similarly in both groups. Left ventricular end systolic and diastolic diameters with TAC were increased compared to shams on the HFD (p < 0.05) but were not different from STD TAC mice. High fat feeding increased expression of PPARα-regulated genes. The activity of medium chain acyl-coenzyme A dehydrogenase (MCAD), a marker of fatty acid oxidation capacity, was increased in HFD TAC mice compared to STD, consistent with PPARα activation. Conclusion Increased fat intake prevented the fall in MCAD activity and did not exacerbate the hypertrophic response to TAC compared to a low-fat diet. PMID:18226777
Quan, Hui; Zhang, Ji
2003-09-15
Analyses of study variables are frequently based on log transformations. To calculate the power for detecting the between-treatment difference in the log scale, we need an estimate of the standard deviation of the log-transformed variable. However, in many situations a literature search only provides the arithmetic means and the corresponding standard deviations. Without individual log-transformed data to directly calculate the sample standard deviation, we need alternative methods to estimate it. This paper presents methods for estimating and constructing confidence intervals for the standard deviation of a log-transformed variable given the mean and standard deviation of the untransformed variable. It also presents methods for estimating the standard deviation of change from baseline in the log scale given the means and standard deviations of the untransformed baseline value, on-treatment value and change from baseline. Simulations and examples are provided to assess the performance of these estimates. Copyright 2003 John Wiley & Sons, Ltd.
Evolutionary Software Development (Developpement Evolutionnaire de Logiciels)
2008-08-01
development processes. While this may be true, frequently it is not. MIL-STD-498 was explicitly introduced to encourage iterative development; ISO /IEC... 12207 was carefully worded not to prohibit iterative development. Yet both standards were widely interpreted as requiring waterfall development, as
Evolutionary Software Development (Developpement evolutionnaire de logiciels)
2008-08-01
development processes. While this may be true, frequently it is not. MIL-STD-498 was explicitly introduced to encourage iterative development; ISO /IEC... 12207 was carefully worded not to prohibit iterative development. Yet both standards were widely interpreted as requiring waterfall development, as
Assessing the Impact of Auditory Peripheral Displays for UAV Operators
2007-11-01
Institute of Technology,Department of Aeronautics and Astronautics,Cambridge,MA,02139 8 . PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING...unclassified Standard Form 298 (Rev. 8 -98) Prescribed by ANSI Std Z39-18 ii Table of Contents ABSTRACT... 8 Dependent Variables
Laser scatter feature of surface defect on apples
NASA Astrophysics Data System (ADS)
Rao, Xiuqin; Ying, Yibin; Cen, YiKe; Huang, Haibo
2006-10-01
A machine vision system for real-time fruit quality inspection was developed. The system consists of a chamber, a laser projector, a TMS-7DSP CCD camera (PULNIX Inc.), and a computer. A Meteor-II/MC frame grabber (Matrox Graphics Inc.) was inserted into the slot of the computer to grab fruit images. The laser projector and the camera were mounted at the ceiling of the chamber. An apple was put in the chamber, the spot of the laser projector was projected on the surface of the fruit, and an image was grabbed. 2 breed of apples was test, Each apple was imaged twice, one was imaged for the normal surface, and the other for the defect. The red component of the images was used to get the feature of the defect and the sound surface of the fruits. The average value, STD value and comentropy Value of red component of the laser scatter image were analyzed. The Standard Deviation value of red component of normal is more suitable to separate the defect surface from sound surface for the ShuijinFuji apples, but for bintang apples, there is more work need to do to separate the different surface with laser scatter image.
Electromagnetic Environmental Effects System Testing
2009-09-02
Procedure (TOP) 1-2-511 Electromagnetic Environmental Effects System Testing 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...airborne, sea, space, and ground systems , including associated ordnance, as stated in military standard (MIL-STD)-464A “Electromagnetic Environmental...Effects Requirement for Systems ”, as well as ADS-37A-PRF “Aeronautical Design Standard for the Electromagnetic Environmental Effects (E3) Performance and
Military Standard: Sanitation Standards for Food Storage Facilities
1989-08-31
maintenance of equipment and utensils ---------------------- 10 5.11 Cleaning and sanitizing treatment ------------- 10 5.12 Methods ...STD-909 3. DEFINITIONS 3.1 Adequate. Methods that are needed to accomplish the intended purpose in keeping with accepted public health practices. 3.2...Inspection and Grading Programs" or approved by the Major Army Command (MACON) Surgeon. 5.11 Cleaning and sanitizing treatment. The methods used for
Targeted NextGen Capabilities for 2025
2011-11-01
increased arrival capacity to single runways by reducing longitudinal wake separation standards for Instrument Flight Rules ( IFR ) operations under certain...b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Targeted NextGen Capabilities...The examples cited are not intended to cover every aircraft and every flight. In some instances, the available capabilities for 2025 will not be
STD testing policies and practices in U.S. city and county jails.
Parece, M S; Herrera, G A; Voigt, R F; Middlekauff, S L; Irwin, K L
1999-09-01
Studies have shown that sexually transmitted disease (STD) rates are high in the incarcerated population. However, little is known about STD testing policies or practices in jails. To assess STD testing policies and practices in jails. The Division of STD Prevention developed and distributed an e-mail survey to 94 counties reporting more than 40 primary and secondary cases in 1996 or having cities with more than 200,000 persons. State and local STD program managers completed the assessment in collaboration with health departments and the main jail facilities in the selected counties. Most facilities (52-77%) had a policy for STD screening based only on symptoms or by arrestee request, and in these facilities, 0.2% to 6% of arrestees were tested. Facilities having a policy of offering routine testing tested only 3% to 45% of arrestees. Large facilities, facilities using public providers, and facilities routinely testing for syphilis using Stat RPR tested significantly more arrestees (P<0.05). Approximately half of the arrestees were released within 48 hours after intake, whereas 45% of facilities did not have STD testing results until after 48 hours. Most facilities had a policy for STD screening based only on symptoms or by arrestee request. Facilities having a policy of routine STD testing are not testing most of the arrestees. There is a small window (<48 hours) for STD testing and treatment before release. Smaller jails and facilities using private providers may need additional resources to increase STD testing levels. Correctional facilities should be considered an important setting for STD public health intervention where routine rapid STD screening and treatment on-site could be implemented.
NASA Technical Reports Server (NTRS)
Avila, Arturo
2011-01-01
The Standard JPL thermal engineering practice prescribes worst-case methodologies for design. In this process, environmental and key uncertain thermal parameters (e.g., thermal blanket performance, interface conductance, optical properties) are stacked in a worst case fashion to yield the most hot- or cold-biased temperature. Thus, these simulations would represent the upper and lower bounds. This, effectively, represents JPL thermal design margin philosophy. Uncertainty in the margins and the absolute temperatures is usually estimated by sensitivity analyses and/or by comparing the worst-case results with "expected" results. Applicability of the analytical model for specific design purposes along with any temperature requirement violations are documented in peer and project design review material. In 2008, NASA released NASA-STD-7009, Standard for Models and Simulations. The scope of this standard covers the development and maintenance of models, the operation of simulations, the analysis of the results, training, recommended practices, the assessment of the Modeling and Simulation (M&S) credibility, and the reporting of the M&S results. The Mars Exploration Rover (MER) project thermal control system M&S activity was chosen as a case study determining whether JPL practice is in line with the standard and to identify areas of non-compliance. This paper summarizes the results and makes recommendations regarding the application of this standard to JPL thermal M&S practices.
NASA Technical Reports Server (NTRS)
Houbec, Keith; Tillman, Barry; Connolly, Janis
2010-01-01
For decades, Space Life Sciences and NASA as an Agency have considered NASA-STD-3000, Man-Systems Integration Standards, a significant contribution to human spaceflight programs and to human-systems integration in general. The document has been referenced in numerous design standards both within NASA and by organizations throughout the world. With research program and project results being realized, advances in technology and new information in a variety of topic areas now available, the time arrived to update this extensive suite of requirements and design information. During the past several years, a multi-NASA center effort has been underway to write the update to NASA-STD-3000 with standards and design guidance that would be applicable to all future human spaceflight programs. NASA-STD-3001 - Volumes 1 and 2 - and the Human Integration Design Handbook (HIDH) were created. Volume 1, Crew Health, establishes NASA s spaceflight crew health standards for the pre-flight, in-flight, and post-flight phases of human spaceflight. Volume 2, Human Factors, Habitability and Environmental Health, focuses on the requirements of human-system integration and how the human crew interacts with other systems, and how the human and the system function together to accomplish the tasks for mission success. The HIDH is a compendium of human spaceflight history and knowledge, and provides useful background information and research findings. And as the HIDH is a stand-alone companion to the Standards, the maintenance of the document has been streamlined. This unique and flexible approach ensures that the content is current and addresses the fundamental advances of human performance and human capabilities and constraints research. Current work focuses on the development of new sections of Volume 2 and collecting updates to the HIDH. The new sections in development expand the scope of the standard and address mission operations and support operations. This effort is again collaboration with representatives from the Johnson Space Center Missions Operations and Space Life Sciences Directorates and the Engineering Directorate from Kennedy Space Center as well as discipline experts from across the Agency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levakhina, Y. M.; Mueller, J.; Buzug, T. M.
Purpose: This paper introduces a nonlinear weighting scheme into the backprojection operation within the simultaneous algebraic reconstruction technique (SART). It is designed for tomosynthesis imaging of objects with high-attenuation features in order to reduce limited angle artifacts. Methods: The algorithm estimates which projections potentially produce artifacts in a voxel. The contribution of those projections into the updating term is reduced. In order to identify those projections automatically, a four-dimensional backprojected space representation is used. Weighting coefficients are calculated based on a dissimilarity measure, evaluated in this space. For each combination of an angular view direction and a voxel position anmore » individual weighting coefficient for the updating term is calculated. Results: The feasibility of the proposed approach is shown based on reconstructions of the following real three-dimensional tomosynthesis datasets: a mammography quality phantom, an apple with metal needles, a dried finger bone in water, and a human hand. Datasets have been acquired with a Siemens Mammomat Inspiration tomosynthesis device and reconstructed using SART with and without suggested weighting. Out-of-focus artifacts are described using line profiles and measured using standard deviation (STD) in the plane and below the plane which contains artifact-causing features. Artifacts distribution in axial direction is measured using an artifact spread function (ASF). The volumes reconstructed with the weighting scheme demonstrate the reduction of out-of-focus artifacts, lower STD (meaning reduction of artifacts), and narrower ASF compared to nonweighted SART reconstruction. It is achieved successfully for different kinds of structures: point-like structures such as phantom features, long structures such as metal needles, and fine structures such as trabecular bone structures. Conclusions: Results indicate the feasibility of the proposed algorithm to reduce typical tomosynthesis artifacts produced by high-attenuation features. The proposed algorithm assigns weighting coefficients automatically and no segmentation or tissue-classification steps are required. The algorithm can be included into various iterative reconstruction algorithms with an additive updating strategy. It can also be extended to computed tomography case with the complete set of angular data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shukla-Dave, A; Lu, Y; Hatzoglou, V
2014-06-15
Purpose: To investigate the repeatability of reduced field-of-view diffusion-weighted imaging (rFOV DWI) in quantifying apparent diffusion coefficients (ADCs) for human thyroid glands in a clinical setting. Methods: Nine healthy human volunteers were enrolled and underwent 3T MRI exams. For each volunteer, 3 longitudinal exams (2 weeks apart) with 2 repetitive sessions within each exam, including rFOV and conventional full field-of-view (fFOV) DWI scans, were performed. In the acquired DWI images, a fixed-size region of interest (ROI; diameter=8mm) was placed on thyroid glands to calculate ADC. ADC was calculated using a monoexponential function with a noise correction scheme. The repeatability ofmore » ADC was assessed by using coefficient variation (CV) across sessions or exams, which was defined to be: r = 1-CV, 0 < r < 1, where CV=STD/m, STD is the standard deviation of ADC, and m is the average of ADC across sessions or exams. An experienced radiologist assessed and scored rFOV and fFOV DW images based on image characteristics (1, nondiagnostic; 2, poor; 3, satisfactory; 4, good; and 5, excellent).Analysis of variance (ANOVA) was performed to compare ADC values, CV of ADC, repeatability of ADC across sessions and exams, and radiologic scores between rFOV and fFOV DWI techniques. Results: There was no significant difference in ADC values across sessions and exams either in rFOV or fFOV DWI. The average CVs of both rFOV and fFOV DWI were less than 13%. The repeatability of ADC measurement between rFOV and fFOV DWI was not significantly different. The overall image quality was significantly higher with rFOV DWI than with fFOV DWI. Conclusion: This study suggested that ADCs from both rFOV and fFOV DWI were repeatable, but rFOV DWI had superior imaging quality for human thyroid glands in a clinical setting.« less
Validation of the CrIS fast physical NH3 retrieval with ground-based FTIR
NASA Astrophysics Data System (ADS)
Dammers, Enrico; Shephard, Mark W.; Palm, Mathias; Cady-Pereira, Karen; Capps, Shannon; Lutsch, Erik; Strong, Kim; Hannigan, James W.; Ortega, Ivan; Toon, Geoffrey C.; Stremme, Wolfgang; Grutter, Michel; Jones, Nicholas; Smale, Dan; Siemons, Jacob; Hrpcek, Kevin; Tremblay, Denis; Schaap, Martijn; Notholt, Justus; Erisman, Jan Willem
2017-07-01
Presented here is the validation of the CrIS (Cross-track Infrared Sounder) fast physical NH3 retrieval (CFPR) column and profile measurements using ground-based Fourier transform infrared (FTIR) observations. We use the total columns and profiles from seven FTIR sites in the Network for the Detection of Atmospheric Composition Change (NDACC) to validate the satellite data products. The overall FTIR and CrIS total columns have a positive correlation of r = 0.77 (N = 218) with very little bias (a slope of 1.02). Binning the comparisons by total column amounts, for concentrations larger than 1.0 × 1016 molecules cm-2, i.e. ranging from moderate to polluted conditions, the relative difference is on average ˜ 0-5 % with a standard deviation of 25-50 %, which is comparable to the estimated retrieval uncertainties in both CrIS and the FTIR. For the smallest total column range (< 1.0 × 1016 molecules cm-2) where there are a large number of observations at or near the CrIS noise level (detection limit) the absolute differences between CrIS and the FTIR total columns show a slight positive column bias. The CrIS and FTIR profile comparison differences are mostly within the range of the single-level retrieved profile values from estimated retrieval uncertainties, showing average differences in the range of ˜ 20 to 40 %. The CrIS retrievals typically show good vertical sensitivity down into the boundary layer which typically peaks at ˜ 850 hPa (˜ 1.5 km). At this level the median absolute difference is 0.87 (std = ±0.08) ppb, corresponding to a median relative difference of 39 % (std = ±2 %). Most of the absolute and relative profile comparison differences are in the range of the estimated retrieval uncertainties. At the surface, where CrIS typically has lower sensitivity, it tends to overestimate in low-concentration conditions and underestimate in higher atmospheric concentration conditions.
Wagstaff, Jane L; Taylor, Samantha L; Howard, Mark J
2013-04-05
This review aims to illustrate that STD NMR is not simply a method for drug screening and discovery, but has qualitative and quantitative applications that can answer fundamental and applied biological and biomedical questions involving molecular interactions between ligands and proteins. We begin with a basic introduction to the technique of STD NMR and report on recent advances and biological applications of STD including studies to follow the interactions of non-steroidal anti-inflammatories, minimum binding requirements for virus infection and understating inhibition of amyloid fibre formation. We expand on this introduction by reporting recent STD NMR studies of live-cell receptor systems, new methodologies using scanning STD, magic-angle spinning STD and approaches to use STD NMR in a quantitative fashion for dissociation constants and group epitope mapping (GEM) determination. We finish by outlining new approaches that have potential to influence future applications of the technique; NMR isotope-editing, heteronuclear multidimensional STD and (19)F STD methods that are becoming more amenable due to the latest NMR equipment technologies.
Determinants of pain treatment response and nonresponse: identification of TMD patient subgroups.
Litt, Mark D; Porto, Felipe B
2013-11-01
The purpose of the present study was to determine if we could identify a specific subtype of temporomandibular disorder (TMD) pain patients that does not respond to treatment. Patients were 101 men and women with chronic TMD pain recruited from the community and randomly assigned to 1 of 2 treatment conditions: a standard conservative care (STD) condition or a standard care plus cognitive-behavioral therapy condition (STD + CBT) in which patients received all elements of STD but also received cognitive-behavioral coping skills training. Growth mixture modeling, incorporating a series of treatment-related predictors, was used to distinguish several distinct classes of responders or nonresponders to treatment based on reported pain over a 1-year follow-up period. Results indicated that treatment nonresponders accounted for 16% of the sample and did not differ from treatment responders on demographics or temporomandibular joint pathology, but that they reported more psychiatric symptoms, poorer coping, and higher levels of catastrophizing. Treatment-related predictors of membership in treatment responder groups versus the nonresponder group included the addition of CBT to STD, treatment attendance, and decreasing catastrophization. It was concluded that CBT may be made more efficacious for TMD patients by placing further emphasis on decreasing catastrophization and on individualizing care. This article provides evidence that the TMD chronic pain population is heterogeneous and that a subsample of patients will be unresponsive to standard or psychosocial approaches. The addition of CBT to treatment may be helpful for this group, but new individualized approaches will be needed to treat all patients effectively. Copyright © 2013 American Pain Society. Published by Elsevier Inc. All rights reserved.
7 CFR 400.204 - Notification of deviation from standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from standards. 400.204... Contract-Standards for Approval § 400.204 Notification of deviation from standards. A Contractor shall advise the Corporation immediately if the Contractor deviates from the requirements of these standards...
Spaceflight Human System Standards
NASA Technical Reports Server (NTRS)
Holubec, Keith; Tillman, Barry; Connolly, Jan
2009-01-01
NASA created a new approach for human system integration and human performance standards. NASA created two documents a standard and a reference handbook. The standard is titled NASA Space Flight Human-System Standard (SFHSS) and consists of two-volumes: Volume 1- Crew Health This volume covers standards needed to support astronaut health (medical care, nutrition, sleep, exercise, etc.) Volume 2 Human Factors, Habitability and Environmental Health This volume covers the standards for system design that will maintain astronaut performance (ie., environmental factors, design of facilities, layout of workstations, and lighting requirements). It includes classic human factors requirements. The new standards document is written in terms so that it is applicable to a broad range of present and future NASA systems. The document states that all new programs prepare system-specific requirements that will meet the general standards. For example, the new standard does not specify a design should accommodate specific percentiles of a defined population. Rather, NASA-STD-3001, Volume 2 states that all programs shall prepare program-specific requirements that define the user population and their size ranges. The design shall then accommodate the full size range of those users. The companion reference handbook, Human Integration Design Handbook (HIDH), was developed to capture the design consideration information from NASA-STD-3000, and adds spaceflight lessons learned, gaps in knowledge, example solutions, and suggests research to further mature specific disciplines. The HIDH serves two major purposes: HIDH is the reference document for writing human factors requirements for specific systems. HIDH contains design guidance information that helps insure that designers create systems which safely and effectively accommodate the capabilities and limitations of space flight crews.
The Standard Deviation of Launch Vehicle Environments
NASA Technical Reports Server (NTRS)
Yunis, Isam
2005-01-01
Statistical analysis is used in the development of the launch vehicle environments of acoustics, vibrations, and shock. The standard deviation of these environments is critical to accurate statistical extrema. However, often very little data exists to define the standard deviation and it is better to use a typical standard deviation than one derived from a few measurements. This paper uses Space Shuttle and expendable launch vehicle flight data to define a typical standard deviation for acoustics and vibrations. The results suggest that 3dB is a conservative and reasonable standard deviation for the source environment and the payload environment.
Ferrando, Carlos; Soro, Marina; Unzueta, Carmen; Suarez-Sipmann, Fernando; Canet, Jaume; Librero, Julián; Pozo, Natividad; Peiró, Salvador; Llombart, Alicia; León, Irene; India, Inmaculada; Aldecoa, Cesar; Díaz-Cambronero, Oscar; Pestaña, David; Redondo, Francisco J; Garutti, Ignacio; Balust, Jaume; García, Jose I; Ibáñez, Maite; Granell, Manuel; Rodríguez, Aurelio; Gallego, Lucía; de la Matta, Manuel; Gonzalez, Rafael; Brunelli, Andrea; García, Javier; Rovira, Lucas; Barrios, Francisco; Torres, Vicente; Hernández, Samuel; Gracia, Estefanía; Giné, Marta; García, María; García, Nuria; Miguel, Lisset; Sánchez, Sergio; Piñeiro, Patricia; Pujol, Roger; García-Del-Valle, Santiago; Valdivia, José; Hernández, María J; Padrón, Oto; Colás, Ana; Puig, Jaume; Azparren, Gonzalo; Tusman, Gerardo; Villar, Jesús; Belda, Javier
2018-03-01
The effects of individualised perioperative lung-protective ventilation (based on the open-lung approach [OLA]) on postoperative complications is unknown. We aimed to investigate the effects of intraoperative and postoperative ventilatory management in patients scheduled for abdominal surgery, compared with standard protective ventilation. We did this prospective, multicentre, randomised controlled trial in 21 teaching hospitals in Spain. We enrolled patients who were aged 18 years or older, were scheduled to have abdominal surgery with an expected time of longer than 2 h, had intermediate-to-high-risk of developing postoperative pulmonary complications, and who had a body-mass index less than 35 kg/m 2 . Patients were randomly assigned (1:1:1:1) online to receive one of four lung-protective ventilation strategies using low tidal volume plus positive end-expiratory pressure (PEEP): open-lung approach (OLA)-iCPAP (individualised intraoperative ventilation [individualised PEEP after a lung recruitment manoeuvre] plus individualised postoperative continuous positive airway pressure [CPAP]), OLA-CPAP (intraoperative individualised ventilation plus postoperative CPAP), STD-CPAP (standard intraoperative ventilation plus postoperative CPAP), or STD-O 2 (standard intraoperative ventilation plus standard postoperative oxygen therapy). Patients were masked to treatment allocation. Investigators were not masked in the operating and postoperative rooms; after 24 h, data were given to a second investigator who was masked to allocations. The primary outcome was a composite of pulmonary and systemic complications during the first 7 postoperative days. We did the primary analysis using the modified intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT02158923. Between Jan 2, 2015, and May 18, 2016, we enrolled 1012 eligible patients. Data were available for 967 patients, whom we included in the final analysis. Risk of pulmonary and systemic complications did not differ for patients in OLA-iCPAP (110 [46%] of 241, relative risk 0·89 [95% CI 0·74-1·07; p=0·25]), OLA-CPAP (111 [47%] of 238, 0·91 [0·76-1·09; p=0·35]), or STD-CPAP groups (118 [48%] of 244, 0·95 [0·80-1·14; p=0·65]) when compared with patients in the STD-O 2 group (125 [51%] of 244). Intraoperatively, PEEP was increased in 69 (14%) of patients in the standard perioperative ventilation groups because of hypoxaemia, and no patients from either of the OLA groups required rescue manoeuvres. In patients who have major abdominal surgery, the different perioperative open lung approaches tested in this study did not reduce the risk of postoperative complications when compared with standard lung-protective mechanical ventilation. Instituto de Salud Carlos III of the Spanish Ministry of Economy and Competitiveness, and Grants Programme of the European Society of Anaesthesiology. Copyright © 2018 Elsevier Ltd. All rights reserved.
Azuma, Junichi; Ohno, Masako; Kubota, Ryuji; Yokota, Soichiro; Nagai, Takayuki; Tsuyuguchi, Kazunari; Okuda, Yasuhisa; Takashima, Tetsuya; Kamimura, Sayaka; Fujio, Yasushi; Kawase, Ichiro
2013-05-01
This study is a pharmacogenetic clinical trial designed to clarify whether the N-acetyltransferase 2 gene (NAT2) genotype-guided dosing of isoniazid improves the tolerability and efficacy of the 6-month four-drug standard regimen for newly diagnosed pulmonary tuberculosis. In a multicenter, parallel, randomized, and controlled trial with a PROBE design, patients were assigned to either conventional standard treatment (STD-treatment: approx. 5 mg/kg of isoniazid for all) or NAT2 genotype-guided treatment (PGx-treatment: approx. 7.5 mg/kg for patients homozygous for NAT2 4: rapid acetylators; 5 mg/kg, patients heterozygous for NAT2 4: intermediate acetylators; 2.5 mg/kg, patients without NAT2 4: slow acetylators). The primary outcome included incidences of 1) isoniazid-related liver injury (INH-DILI) during the first 8 weeks of therapy, and 2) early treatment failure as indicated by a persistent positive culture or no improvement in chest radiographs at the 8th week. One hundred and seventy-two Japanese patients (slow acetylators, 9.3 %; rapid acetylators, 53.5 %) were enrolled in this trial. In the intention-to-treat (ITT) analysis, INH-DILI occurred in 78 % of the slow acetylators in the STD-treatment, while none of the slow acetylators in the PGx-treatment experienced either INH-DILI or early treatment failure. Among the rapid acetylators, early treatment failure was observed with a significantly lower incidence rate in the PGx-treatment than in the STD-treatment (15.0 % vs. 38 %). Thus, the NAT2 genotype-guided regimen resulted in much lower incidences of unfavorable events, INH-DILI or early treatment failure, than the conventional standard regimen. Our results clearly indicate a great potential of the NAT2 genotype-guided dosing stratification of isoniazid in chemotherapy for tuberculosis.
Human Integration Design Processes (HIDP)
NASA Technical Reports Server (NTRS)
Boyer, Jennifer
2014-01-01
The purpose of the Human Integration Design Processes (HIDP) document is to provide human-systems integration design processes, including methodologies and best practices that NASA has used to meet human systems and human rating requirements for developing crewed spacecraft. HIDP content is framed around human-centered design methodologies and processes in support of human-system integration requirements and human rating. NASA-STD-3001, Space Flight Human-System Standard, is a two-volume set of National Aeronautics and Space Administration (NASA) Agency-level standards established by the Office of the Chief Health and Medical Officer, directed at minimizing health and performance risks for flight crews in human space flight programs. Volume 1 of NASA-STD-3001, Crew Health, sets standards for fitness for duty, space flight permissible exposure limits, permissible outcome limits, levels of medical care, medical diagnosis, intervention, treatment and care, and countermeasures. Volume 2 of NASASTD- 3001, Human Factors, Habitability, and Environmental Health, focuses on human physical and cognitive capabilities and limitations and defines standards for spacecraft (including orbiters, habitats, and suits), internal environments, facilities, payloads, and related equipment, hardware, and software with which the crew interfaces during space operations. The NASA Procedural Requirements (NPR) 8705.2B, Human-Rating Requirements for Space Systems, specifies the Agency's human-rating processes, procedures, and requirements. The HIDP was written to share NASA's knowledge of processes directed toward achieving human certification of a spacecraft through implementation of human-systems integration requirements. Although the HIDP speaks directly to implementation of NASA-STD-3001 and NPR 8705.2B requirements, the human-centered design, evaluation, and design processes described in this document can be applied to any set of human-systems requirements and are independent of reference missions. The HIDP is a reference document that is intended to be used during the development of crewed space systems and operations to guide human-systems development process activities.
Yun, Seong-Hoon; Park, Eun-Seon; Shin, Sung-Won; Ju, Mi-Ha; Han, Jin-Yeong; Jeong, Jin-Sook; Kim, Sung-Hyun; Stonik, Valentin A.; Kwak, Jong-Young; Park, Joo-In
2015-01-01
Stichoposide D (STD) is a marine triterpene glycoside isolated from sea cucumbers. We examined the molecular mechanisms underlying the antitumor activity of STD in human leukemia cells. The role of Fas (CD95), ceramide synthase 6 (CerS6) and p38 kinase during STD-induced apoptosis was examined in human leukemia cells. In addition, the antitumor effects of STD in K562 and HL-60 leukemia xenograft models were investigated. We found that STD induces Fas translocation to lipid rafts, and thus mediates cell apoptosis. We also observed the activation of CerS6 and p38 kinase during STD-induced apoptosis. The use of methyl-β-cyclodextrin and nystatin to disrupt lipid rafts prevents the clustering of Fas and the activation of CerS6 and p38 kinase, and also inhibits STD-induced apoptosis. Specific inhibition by Fas, CerS6, and p38 kinase siRNA transfection partially blocked STD-induced apoptosis. In addition, STD has antitumor activity through the activation of CerS6 and p38 kinase without displaying any toxicity in HL-60 and K562 xenograft models. We observed that the anti-tumor effect of STD is partially prevented in CerS6 shRNA-silenced xenograft models. We first report that Fas/CerS6/p38 kinase activation in lipid rafts by STD is involved in its anti-leukemic activity. We also established that STD is able to enhance the chemosensitivity of K562 cells to etoposide or Ara-C. These data suggest that STD may be used alone or in combination with other chemotherapeutic agents to treat leukemia. PMID:26318294
Sexually Transmitted Diseases Surveillance, 2014: Syphilis
... 2014 Sexually Transmitted Diseases Surveillance Table of Contents Introductory Section Foreword Preface Acronyms Figures- National Profile Figures – ... GISP Profiles Related Links STD Home STD Data & Statistics NCHHSTP Atlas Interactive STD Data – 1996-2013 STD ...
2012 Sexually Transmitted Diseases Surveillance, Other Sexually Transmitted Diseases
... 2012 Sexually Transmitted Diseases Surveillance Table of Contents Introductory Section Foreword Preface Acronyms Figures- National Profile Figures - ... GISP Profiles Related Links STD Home STD Data & Statistics NCHHSTP Atlas Interactive STD Data - 1996-2013 STD ...
NASA Technical Reports Server (NTRS)
Hughitt, Brian; Generazio, Edward (Principal Investigator); Nichols, Charles; Myers, Mika (Principal Investigator); Spencer, Floyd (Principal Investigator); Waller, Jess (Principal Investigator); Wladyka, Jordan (Principal Investigator); Aldrin, John; Burke, Eric; Cerecerez, Laura;
2016-01-01
NASA-STD-5009 requires that successful flaw detection by NDE methods be statistically qualified for use on fracture critical metallic components, but does not standardize practices. This task works towards standardizing calculations and record retention with a web-based tool, the NNWG POD Standards Library or NPSL. Test methods will also be standardized with an appropriately flexible appendix to -5009 identifying best practices. Additionally, this appendix will describe how specimens used to qualify NDE systems will be cataloged, stored and protected from corrosion, damage, or loss.
Nitschke, H; Ludwig-Diouf, B; Knappik, A; Leidel, J
2006-11-01
When in 2001 in Germany the new act for control of infectious diseases came into force, mandatory checks for prostitutes were abolished. The consequences of this paradigm shift in STD prevention are being judged controversially even today. The public health department of the city of Cologne, like others, adapted its programme, staff, equipment, and diagnostic procedures to the new requirements. The department for venereal disease control was converted into a walk-in-clinic for STD and now forms part of a comprehensive STD and Aids prevention unit. The present article illustrates the changes by comparing the clients and the STD numbers of the years 1994 and 2004. The following data were compared: number of consultations, number of clients regarding sex, occupation in sex business, health insurance, national or ethnic background, frequency of consultation, number of STD. In 1994, almost all clients of the department for venereal disease control were female prostitutes. 74% of them worked in established sex business venues with a high grade of professionalism, few STD cases were diagnosed. In 2004, the STD clinic was open for anybody considered to be at risk and not having access to the regular health care system. Only 49% of the patients were prostitutes, either female or male. 25% of the clients were male. 68% of the patients were migrants, many of them without any legal status and without any access to regular health care. A high number of acute STD and subsequent disorders that required treatment was registered. Besides the STD-related services, a great need for gynaecological and urological differential diagnostics as well as a high demand for counselling and provision of other problems of sexual health were observed. The data show that an STD department providing comprehensive services anonymously and free of charge will reach a broader range of highly vulnerable persons in comparison with an obligatory VD check of prostitutes. The high numbers of STD and STD-related disorders demonstrate the improved effectiveness of the new service.
SHIPMENT OF TWO DOE-STD-3013 CONTAINERS IN A 9977 TYPE B PACKAGE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abramczyk, G.; Bellamy, S.; Loftin, B.
2011-06-06
The 9977 is a certified Type B Packaging authorized to ship uranium and plutonium in metal and oxide forms. Historically, the standard container for these materials has been the DOE-STD-3013 which was specifically designed for the long term storage of plutonium bearing materials. The Department of Energy has used the 9975 Packaging containing a single 3013 container for the transportation and storage of these materials. In order to reduce container, shipping, and storage costs, the 9977 Packaging is being certified for transportation and storage of two 3013 containers. The challenges and risks of this content and the 9977s ability tomore » meet the Code of Federal Regulations for the transport of these materials are presented.« less
NASA Technical Reports Server (NTRS)
Plante, Jeannete
2010-01-01
GEIA-STD-0005-1 defines the objectives of, and requirements for, documenting processes that assure customers and regulatory agencies that AHP electronic systems containing lead-free solder, piece parts, and boards will satisfy the applicable requirements for performance, reliability, airworthiness, safety, and certify-ability throughout the specified life of performance. It communicates requirements for a Lead-Free Control Plan (LFCP) to assist suppliers in the development of their own Plans. The Plan documents the Plan Owner's (supplier's) processes, that assure their customer, and all other stakeholders that the Plan owner's products will continue to meet their requirements. The presentation reviews quality assurance requirements traceability and LFCP template instructions.
Chesson, Harrell W
2012-03-01
The purpose of this review is to highlight selected studies in the economics literature that address sexually transmitted disease (STD)-related topics that are typically not examined in the STD literature. Two databases (EconLit and Web of Science) were searched to locate STD-related articles in the economics journals. Relevant articles were also identified in other ways, such as informal discussions with colleagues familiar with the literature. To maintain a focus on unique STD-related topics, studies with topics common in the STD literature (e.g., cost-effectiveness, transmission modeling) were excluded. Selected STD-related studies in the economics literature were grouped into the following 8 topics: impact of abortion laws and policies on sexual health outcomes; same-sex marriage and syphilis rates; alcohol policy and STD rates; welfare laws and STD rates; discounting the future; HIV disclosure laws; the impact of tolerance for gays on HIV incidence; and economic versus epidemiologic models of HIV dynamics. A general theme of STD-related studies in the economics literature is that laws and policies that increased the "cost" of risky sex tended to reduce the demand for risky sex, and therefore reduce the incidence of STDs. Economic research can contribute in novel ways to our understanding of influences on risky sexual behavior at the individual level and STD incidence at the population level. Economists and STD experts could mutually benefit from increased collaboration.
A Model for Joint Software Reviews
1998-10-01
CEPMAN 1, 1996; Gabb, 1997], and with the growing popularity of outsourcing, they are becoming more important in the commercial sector [ ISO /IEC 12207 ...technical and management reviews [MIL-STD-498, 1996; ISO /IEC 12207 , 1995]. Management reviews occur after technical reviews, and are focused on the cost...characteristics, Standard (No. ISO /IEC 9126-1). [ ISO /IEC 12207 , 1995] Information Technology Software Life Cycle Processes, Standard (No. ISO /IEC 12207
NASA-STD-6016 Standard Materials and Processes Requirements for Spacecraft
NASA Technical Reports Server (NTRS)
Hirsch, David B.
2009-01-01
The standards for materials and processes surrounding spacecraft are discussed. Presentation focused on minimum requirements for Materials and Processes (M&P) used in design, fabrication, and testing of flight components for NASA manned, unmanned, robotic, launch vehicle, lander, in-space and surface systems, and spacecraft program/project hardware elements.Included is information on flammability, offgassing, compatibility requirements, and processes; both metallic and non-metallic materials are mentioned.
Tarp, Jakob; Andersen, Lars Bo; Gejl, Anne Kær; Huang, Tao; Peijs, Lone; Bugge, Anna
2017-01-01
Background and objective Cardiovascular disease and type 2 diabetes pose a global health burden. Therefore, clarifying the pathology of these risk factors is essential. Previous studies have found positive and negative associations between one or more cardiovascular risk factors and brain-derived neurotrophic factor (BDNF) probably due to diverse methodological approaches when analysing peripheral BDNF levels. Moreover, only a few studies have been performed in youth populations. Consequently, the main objective of this study was to examine the association between serum BDNF and a composite z-score consisting of six cardiovascular risk factors. A secondary aim was to examine the associations between serum BDNF and each of the six risk factors. Methods Four hundred and forty-seven apparently healthy adolescents between 11–17 years of age participated in this cross-sectional study. Cardiorespiratory fitness (CRF), anthropometrics, pubertal status, blood pressure (BP), serum BDNF, high-density lipoprotein cholesterol (HDL-C), triglyceride (TG), blood glucose and insulin were measured. Information about alcohol consumption and socio-economic status was collected via questionnaires. Associations were modelled using linear regression analysis. Results Serum BDNF was positively associated with the composite z-score in the total study sample (standardized beta coefficient (std.β) = 0.10, P = 0.037). In males, serum BDNF was positively associated with the composite z-score (Std. β = 0.14, P = 0.034) and HOMA-IR (Std. β = 0.19, P = 0.004), and negatively associated with CRF (Std. β = -0.15, P = 0.026). In females, BDNF was positively associated with TG (Std. β = 0.14, P = 0.030) and negatively associated with waist circumference (WC) (Std. β = -0.16, P = 0.012). Conclusion Serum BDNF was positively associated with a composite z-score of cardiovascular risk factors. This association seems to be mainly driven by the association between TG, HOMA-IR and serum BDNF, and particularly for males. Further longitudinal research is warranted to determine the temporal relationship between BDNF and cardiovascular risk factors. PMID:29028824
An assessment of care provided by a public sector STD clinic in Cape Town.
Mathews, C; van Rensburg, A; Schierhout, G; Coetzee, N; Lombard, C J; Fehler, H G; Ballard, R C
1998-11-01
A study was undertaken in a Cape Town public sector STD clinic to evaluate the content and quality of care provided since it has been recognized that appropriate improvements in the management of conventional sexually transmitted diseases (STDs), including provision of correct therapy, health education, condom promotion and partner notification, could result in a reduced incidence of HIV infection. Our objectives were to assess patients' needs for health education and to assess the quality of STD management in terms of health education, condom promotion, partner notification, the validity of the clinical diagnoses and the adequacy of the treatments prescribed. The study subjects were sampled systematically, according to their gender. Patients included in the study were given a standardized interview and their clinical records reviewed. Specimens were collected for laboratory investigations. For each STD detected, the treatment was defined as adequate if drugs currently known to be active against that infection were prescribed. One hundred and seventy men and 161 women were included in the study (median age: females 22 years, males 26 years). While almost all patients believed their STD may have been caused by unprotected sexual intercourse, many also believed it may have been caused by other factors, such as bewitchment with traditional medicine. Only 21% of male and 37% of female patients received any education about STD transmission during the clinic visit, and only 25% of male and 36% of female patients received education about condom use. As a result of the low sensitivity of the clinicians' diagnoses, 16% of men and 61% of women left the clinic with at least one infection inadequately treated. The majority of patients were not receiving education for the prevention of STDs including HIV. Many were not receiving adequate treatment for their infections. The introduction of a syndromic management protocol in this setting would substantially reduce the proportion of inadequately-treated patients. However, syndromic protocols, and the means by which they are implemented, need to take into account problems with the clinical detection of genital ulcerative disease and candidiasis in women.
Cuffe, Kendra M; Esie, Precious; Leichliter, Jami S; Gift, Thomas L
2017-04-07
The incidence of human immunodeficiency virus (HIV) infection in the United States is higher among persons with other sexually transmitted diseases (STDs), and the incidence of other STDs is increased among persons with HIV infection (1). Because infection with an STD increases the risk for HIV acquisition and transmission (1-4), successfully treating STDs might help reduce the spread of HIV among persons at high risk (1-4). Because health department STD programs provide services to populations who are at risk for HIV, ensuring service integration and coordination could potentially reduce the incidence of STDs and HIV. Program integration refers to the combining of STD and HIV prevention programs through structural, service, or policy-related changes such as combining funding streams, performing STD and HIV case matching, or integrating staff members (5). Some STD programs in U.S. health departments are partially or fully integrated with an HIV program (STD/HIV program), whereas other STD programs are completely separate. To assess the extent of provision of HIV services by state and local health department STD programs, CDC analyzed data from a sample of 311 local health departments and 56 state and directly funded city health departments derived from a national survey of STD programs. CDC found variation in the provision of HIV services by STD programs at the state and local levels. Overall, 73.1% of state health departments and 16.1% of local health departments matched STD case report data with HIV data to analyze possible syndemics (co-occurring epidemics that exacerbate the negative health effects of any of the diseases) and overlaps. Similarly, 94.1% of state health departments and 46.7% of local health departments performed site visits to HIV care providers to provide STD information or public health updates. One fourth of state health departments and 39.4% of local health departments provided HIV testing in nonclinical settings (field testing) for STD contacts, and all of these programs linked HIV cases to care. STD programs are providing some HIV services; however, delivery of certain specific services could be improved.
Unobtrusive Social Network Data From Email
2008-12-01
PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 outlook archived files and stores that data into an SQL - database. Communication...Applications ( VBA ) program was installed on the personal computers (PC) of all participants, in the session window of their Microsoft Outlook. Details of
2009-01-01
REPORT unclassified b. ABSTRACT unclassified c . THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 44...Panda, Head of the Water Initiative of Orrissa, interview with author, 24 July 2008. 10. S. R. Ramanujan , “Andhra Pradesh: Peace Talks with PWG?” South
Correlates of HIV/STD testing and willingness to test among rural-to-urban migrants in China.
Wang, Bo; Li, Xiaoming; Stanton, Bonita; McGuire, James
2010-08-01
This study investigates socio-demographic, behavioral, psychological, and structural factors associated with self-reported HIV/STD testing and willingness to test among 1,938 Chinese migrants. Overall, 6% and 14% of participants had ever been tested for HIV and STD, respectively. The results of multivariate analyses indicate that working at entertainment sectors, engaging in commercial sex, and utilization of health care were positively associated with both HIV and STD testing. Younger age, selling blood, perceived peer sexual risk involvement, and satisfaction with life were associated with HIV testing only. Female gender, early sexual debut, multiple sexual partners, and perceived vulnerability to HIV/STD were associated with STD testing only. Male gender, having premarital sex, perceived higher severity of and vulnerability to HIV/STD, and utilization of health care were associated with willingness to be tested for both HIV and STD. Interventions designed to raise the perception of vulnerability to HIV/STD and to improve access to and utilization of health care may be effective in encouraging more HIV testing in this vulnerable population.
Current approach to STD management in women.
Amaral, E
1998-12-01
HIV infection was recognized as a new sexually transmitted disease (STD) at the beginning of the last decade. The knowledge of risk factors for sexual transmission of HIV changed the focus on STD to a broader perspective for prevention and control of HIV infection, and consequently of STD. Barriers to STD control include cultural aspects, difficulties in changing sexual behavior, asymptomatic disease in women and expensive and inaccessible tests for diagnosis. The classical clinical approach based on etiologic treatment has never been achieved by developing countries. The international community has been searching for new approaches. Syndromic management and mass treatment are strategies recently found as useful. Nevertheless the best approach to endocervicitis by Neisseria gonorrhoeae and Chlamydia trachomatis remain problematic. Then, the current approach to STD management must include: prompt attention to every patient seeking care for STD; early diagnosis and treatment; delivery of short term treatment at the clinic; education on STD/HIV; screening for other STDs with pre- and post-test counseling; counseling on risk reduction; provision of condoms; integration of STD services with family planning, prenatal and gynecological services.
Recently arrested adolescents are at high risk for sexually transmitted diseases.
Belenko, Steven; Dembo, Richard; Weiland, Doris; Rollie, Matthew; Salvatore, Christopher; Hanlon, Alexandra; Childs, Kristina
2008-08-01
Adolescent offenders may be at high risk for sexually transmitted diseases (STDs). With previous research and interventions focused on incarcerated adolescents, data are needed on STD prevalence and risk factors among newly arrested youth released to the community, a far larger subgroup. Participants were recruited from all arrested youth processed at the Hillsborough County, Florida Juvenile Assessment Center during the last half of 2006 (506 males, 442 females). Participants voluntarily providing urine samples for drug testing as part of standard protocol were also consented to having their specimens split and tested for chlamydia and gonorrhea, using an FDA-approved nucleic acid amplification test. STD prevalence was similar to those previously reported among incarcerated adolescents: 11.5% tested positive for chlamydia, 4.2% for gonorrhea, and 13.2% for either or both infections. Prevalence was significantly higher among females: 19.2% of females had either or both infections compared with 10.5% of males. Prevalence was higher for 17 to 18 year olds (15.2% of males, 25.5% of females), blacks, detained youths, drug users, and those engaged in sexual risk behaviors. Previous STD testing experience was limited. The study indicated that a voluntary STD screening protocol is feasible for arrested youth entering the juvenile justice system, and these offenders are at high risk for STDs. Because most arrested youths are released back to the community, routine testing and treatment of recently arrested youths, and expanded access to risk reduction and prevention programs, can yield substantial public health benefits.
7 CFR 400.174 - Notification of deviation from financial standards.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 6 2010-01-01 2010-01-01 false Notification of deviation from financial standards... Agreement-Standards for Approval; Regulations for the 1997 and Subsequent Reinsurance Years § 400.174 Notification of deviation from financial standards. An insurer must immediately advise FCIC if it deviates from...
Tucker, Joseph D; Yang, Li-Gang; Yang, Bin; Young, Darwin; Henderson, Gail E; Huang, Shu-Jie; Lu, He-Kun; Chen, Xiang-Sheng; Cohen, Myron S
2012-03-01
Expanding HIV testing is important among individuals at increased risk for sexual HIV transmission in China, but little is known about prior HIV testing experiences among sexually transmitted disease (STD) patients. This cross-sectional study of 1792 outpatients from 6 public STD clinics in Guangdong Province recorded detailed information about ever having been tested for HIV infection in addition to sociodemographic variables, health seeking, clinical STD history, and HIV stigma using a validated survey instrument. A total of 456 (25.4%) of the STD patients in this sample had ever been tested for HIV infection. STD patients who were male, had higher income, more education, were at City A and City C, received STD services at public facilities, had used intravenous drugs, and had a history of an STD were more likely to ever receive an HIV test in multivariate analysis. Low perceived HIV risk was the most common reason for not receiving an HIV test. Only 7.7% of the sample reported fear of discrimination or loss of face as influencing their lack of HIV testing. Incomplete prior HIV screening among STD patients in China suggests the need for broadening HIV testing opportunities at STD clinics and similar clinical settings attended by those with increased sexual risk.
Degrees of Freedom for Allan Deviation Estimates of Multiple Clocks
2016-04-01
Allan deviation . Allan deviation will be represented by σ and standard deviation will be represented by δ. In practice, when the Allan deviation of a...the Allan deviation of standard noise types. Once the number of degrees of freedom is known, an approximate confidence interval can be assigned by...measurement errors from paired difference data. We extend this approach by using the Allan deviation to estimate the error in a frequency standard
STD Education: Challenge for the 80s.
ERIC Educational Resources Information Center
Kroger, Fred; Wiesner, Paul J.
1981-01-01
Sexually transmitted diseases (STD) are the most pervasive, destructive, and costly communicable disease problems facing America's youth. The need for and appropriateness of school-based STD education, some elements of high-quality STD education, and strategies for dealing constructively with controversy are discussed. (JN)
47 CFR 80.225 - Requirements for selective calling equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... selective calling (DSC) equipment and selective calling equipment installed in ship and coast stations, and...-STD, “RTCM Recommended Minimum Standards for Digital Selective Calling (DSC) Equipment Providing... Class ‘D’ Digital Selective Calling (DSC)—Methods of testing and required test results,” March 2003. ITU...
40 CFR 1054.706 - How do I generate and calculate evaporative emission credits?
Code of Federal Regulations, 2011 CFR
2011-07-01
... following equation: Emission credits (kg) = (STD−FEL) × (Total Area) × (UL) × (AF) × (365) × (10−3) Where: STD = the emission standard, in g/m2/day. FEL = the family emission limit for the family, in g/m2/day...
40 CFR 1054.706 - How do I generate and calculate evaporative emission credits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... following equation: Emission credits (kg) = (STD−FEL) × (Total Area) × (UL) × (AF) × (365) × (10−3) Where: STD = the emission standard, in g/m2/day. FEL = the family emission limit for the family, in g/m2/day...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-03
.... EERE-2013-BT-STD-0030] RIN 1904-AD01 Energy Efficiency Program for Commercial and Industrial Equipment... Certain Industrial Equipment,'' a program covering certain commercial and industrial equipment (hereafter... (AEMTCA), Public Law 112-210 (Dec. 18, 2012). EPCA covers many types of commercial and industrial...
Discovering Implicit Networks from Point Process Data
2013-08-03
Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 SOCIAL NETWORK ANALYSIS Szell et al, Nature 2012 Saturday, August 3, 13 (a) Adjacency...processes: ‣ Seismology ‣ Epidemiology ‣ Economics ‣ Modeling dependence is challenging - “beyond Poisson” ‣ Strauss and Gibbs Processes ‣ Determinantal
77 FR 31917 - Energy Conservation Program: Energy Conservation Standards for Residential Dishwashers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
... the docket Web page can be found at: http://www.regulations.gov/#!docketDetail ;D=EERE-2011-BT-STD-0060. The regulations.gov Web page contains instructions on how to access all documents, including...: (202) 586-7796. Email: [email protected] . SUPPLEMENTARY INFORMATION: Table of Contents I...
General Theory of a Quantitative Method of Optical Patternation
2003-09-01
Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. 239.18 This Page Intentionally Left Blank iii TABLE OF CONTENTS Section Page...nnPph , , 2|| |ˆˆ| )(),,,ˆˆ(),( λ λλξλ P PPPPP rr , (29) and define the signal attenuation function ),( bpvc pe P as ),(/),(),( bpvbpvbpvc
Assessing the Impact of Haptic Peripheral Displays for UAV Operators
2008-03-01
Institute of Technology,Department of Aeronautics and Astronautics,Cambridge,MA,02139 8 . PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING...PERSON a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8 -98) Prescribed by ANSI Std Z39-18 ii... 8 Experimental Design
1 CFR 21.14 - Deviations from standard organization of the Code of Federal Regulations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 1 General Provisions 1 2010-01-01 2010-01-01 false Deviations from standard organization of the... CODIFICATION General Numbering § 21.14 Deviations from standard organization of the Code of Federal Regulations. (a) Any deviation from standard Code of Federal Regulations designations must be approved in advance...
NASA Astrophysics Data System (ADS)
Hegarty, Michael G.
2005-05-01
The U.S. Air Force is currently in the process of developing a revision to MIL-STD-1553 that will provide additional digital communication bandwidth beyond MIL-STD-1553B's 1 Megabit per second (Mbps) rate. The proposed revision to MIL-STD-1553 (referred to as MIL-STD-1553C) is targeting 200 Mbps as a baseline data rate. This paper explores the feasibility of the U.S. Air Force's proposed revision to MIL-STD-1553 based on studies conducted by Data Device Corporation (DDC). A combination of empirical and theoretical methods is used to determine if a MIL-STD-1553B network contains sufficient capacity to support the proposed 200 Mbps data rate. The results of DDC's analysis is that for some MIL-STD-1553 buses there is sufficient bandwidth to implement a broadband system in which legacy 1 Mbps 1553B waveforms could coexist with new 200 Mbps waveforms, thus providing an incremental high speed communication channel to existing MIL-STD-1553 buses.
Wohlfeiler, Dan; Hecht, Jennifer; Volk, Jonathan; Fisher Raymond, H; Kennedy, Tom; McFarland, Willi
2013-11-01
Internet-based interventions have potential to reduce HIV and STD transmission among men who meet male sexual partners online. From November 2009 to May 2010 we surveyed dating and hook-up website users (n = 3,050), website owners (n = 18), and health department HIV/STD directors (n = 81) to identify structural and behavioral prevention interventions that could be implemented online and which a majority of website users were willing to use, owners were willing to implement, and HIV/STD directors perceived to be effective. A majority of each of the three stakeholder groups agreed on the following: (1) automated HIV/STD testing reminders, (2) local STD test site directories, (3) links to sex-positive safe sex videos, (4) access to sexual health experts, (5) profile options to include safer sex preference, (6) chat rooms for specific sexual interests, (7) filtering partners by their profile information, and (8) anonymous e-card partner notification for STD exposure. Findings help build consensus about how to prioritize resources for implementing online HIV and STD prevention interventions and highlight differences between stakeholders to guide future discussion about how to advance prevention efforts.
Test Operations Procedure (TOP) 03-2-504A Safety Evaluation of Small Arms and Medium Caliber Weapons
2013-05-29
Assessment HHAR Health Hazard Assessment Report HERO Hazards of Electromagnetic Radiation to Ordnance in. inch J Joule km/hr kilometers per hour...help standardize testing and to specify tests commonly used to identify and assess safety hazards associated with the use of small arms. The...19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18
Fleisher, J M; Senie, R T; Minkoff, H; Jaccard, J
1994-12-01
The purpose of this study was to assess knowledge regarding STD spread and prevention, and to assess motivational and behavioral factors that influence the use of condoms to prevent STD acquisition among inner-city women at high risk for STD infection. In addition, the effect of past and/or current STD infection on a woman's knowledge of the mechanism of STD acquisition and subsequent use of a condom to prevent STD infection was explored. We utilized three inner-city clinics offering family planning or gynecologic care located in Brooklyn, New York. Our study linked clinical findings regarding current infection with chlamydia or Trichomonas vaginalis. One thousand four hundred and four sexually active black and Hispanic women participated in the study. A past history of STD (37%) or current infection (29%) was recorded for 54% of the study population (12% were positive for both past and current infection). On average, only 60% of women who reported prior treatment for STD infection reported receiving any information regarding prevention of re-infection during the course of treatment. Depending on the specific STD, from 6.8% to 42.9% of women reporting prior treatment for an STD did not know the disease they were being treated for was sexually transmitted. Condom use for disease prevention was more frequently reported by women who had previously been treated for an STD (OR = 1.62, 95% CI 1.23-2.13). However, condom use for contraception was a stronger predictor of use for STD prevention. Women who relied on condoms for contraception were almost 10 times more likely to also report condom use for STD prevention relative to women who did not use condoms for contraceptive purposes (OR = 9.71, 95% CI 7.0-13.5). In addition, condom use was associated with the perceived attitude of their sexual partner toward such use. Condom use to prevent STD acquisition was more than twice as frequently reported when a favorable attitude was perceived by a male sexual partner (OR = 2.30, 95% CI 1.54-3.43). Our findings suggest that prevention of unplanned pregnancy was a stronger motivator for condom use than disease prevention among the women comprising our study group. The findings also indicate the need for more extensive information regarding STD prevention among women at high risk for STD acquisition.(ABSTRACT TRUNCATED AT 400 WORDS)
Tucker, Joseph D; Yang, Li-Gang; Yang, Bin; Young, Darwin; Henderson, Gail E; Huang, Shu-Jie; Lu, He-Kun; Chen, Xiang-Sheng; Cohen, Myron S
2011-01-01
Background Expanding HIV testing is important among individuals at increased risk for sexual HIV transmission in China, but little is known about prior HIV testing experiences among sexually transmitted disease (STD) patients. Methods This cross-sectional study of 1792 outpatients from six public sexually transmitted disease (STD) clinics in Guangdong Province recorded detailed information about ever having been tested for HIV infection in addition to socio-demographic variables, health seeking, clinical STD history, and HIV stigma using a validated survey instrument. Results 456 (25.4%) of the STD patients in this sample had ever been tested for HIV infection. STD patients who were male, had higher income, more education, were at City A and City C, received STD services at public facilities, had used intravenous drugs, and had a history of an STD were more likely to ever receive an HIV test in multivariate analysis. Low perceived HIV risk was the most common reason for not receiving an HIV test. Only 7.7% of the sample reported fear of discrimination or loss of face as influencing their lack of HIV testing. Conclusion Incomplete prior HIV screening among STD patients in China suggests the need for broadening HIV testing opportunities at STD clinics and similar clinical settings attended by those with increased sexual risk. PMID:22337103
STD coinfections in The Netherlands: Specific sexual networks at highest risk.
van Veen, Maaike G; Koedijk, Femke D H; van der Sande, Marianne A B
2010-07-01
Specific subpopulations infected with multiple bacterial sexually transmitted diseases (STDs) may facilitate ongoing STD transmission. To identify these subpopulations we determined the extent of concurrent incident STD infections and their risk factors among the high-risk population seen at Dutch STD clinics. STD surveillance data submitted routinely by STD clinics to the National Institute for Public Health on demographics, sexual behavior, STD testing, and diagnoses for the period 2004-2007 were analyzed. Bacterial STD coinfections were diagnosed concurrently in 2120 (7%) of the 31,754 incident bacterial STD diagnoses (chlamydia, gonorrhea, infectious syphilis). In univariate logistic regression analyses, coinfections were significantly more often diagnosed in men who have sex with men (MSM, OR = 5.4) than in heterosexuals. Multivariate analyses showed a significant interaction between age and sexual preference. Subsequent stratified analyses by sexual preference showed a linear rise in coinfections with age in MSM. In heterosexuals, by contrast, bacterial coinfections peaked in those aged 19 or less; they had 27% of coinfections, while having only 14% of monodiagnoses and 10% of consultations. Heterosexual STD clinic attendees of Surinamese or Antillean origin were significantly at higher risk for coinfection (OR = 6.5) than all other ethnicities. Attendees belonging to specific sexual networks, such as MSM, ethnic groups, and young heterosexuals were at increased risk for STD coinfections. The different trend with age in MSM versus heterosexuals suggests that these 2 high-risk networks have different determinants of higher risk, such as age-related sexual risk-taking, biologic susceptibility, and insufficient knowledge or compliance with prevention measures. Prevention should therefore be targeted differently towards specific sexual networks.
Upgraded FAA Airfield Capacity Model. Volume 1. Supplemental User’s Guide
1981-02-01
SIGMAR (P4.0) cc 1-4 -standard deviation, in seconds, of arrival runway occupancy time (R.O.T.). SIGMAA (F4.0) cc 5-8 -standard deviation, in seconds...iI SI GMAC - The standard deviation of the time from departure clearance to start of roll. SIGMAR - The standard deviation of the arrival runway
Code of Federal Regulations, 2014 CFR
2014-04-01
.... Each STD shall develop a quality assurance program which will assure that the materials and workmanship... criteria in § 637.207 and be approved by the FHWA. (b) STD capabilities. The STD shall maintain an adequate... qualified sampling and testing personnel employed by the STD or its designated agent. (d) Verification...
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Each STD shall develop a quality assurance program which will assure that the materials and workmanship... criteria in § 637.207 and be approved by the FHWA. (b) STD capabilities. The STD shall maintain an adequate... qualified sampling and testing personnel employed by the STD or its designated agent. (d) Verification...
Code of Federal Regulations, 2012 CFR
2012-04-01
.... Each STD shall develop a quality assurance program which will assure that the materials and workmanship... criteria in § 637.207 and be approved by the FHWA. (b) STD capabilities. The STD shall maintain an adequate... qualified sampling and testing personnel employed by the STD or its designated agent. (d) Verification...
10 CFR 431.447 - Department of Energy recognition of nationally recognized certification programs.
Code of Federal Regulations, 2013 CFR
2013-01-01
... IEEE Std 112-2004 Test Methods A and B, IEEE Std 114-2010, CSA C390-10, and CSA C747 (incorporated by... IEEE Std 112-2004 Test Methods A and B, IEEE Std 114-2010, CSA C390-10, and CSA C747- (incorporated by...
10 CFR 431.447 - Department of Energy recognition of nationally recognized certification programs.
Code of Federal Regulations, 2014 CFR
2014-01-01
... IEEE Std 112-2004 Test Methods A and B, IEEE Std 114-2010, CSA C390-10, and CSA C747 (incorporated by... IEEE Std 112-2004 Test Methods A and B, IEEE Std 114-2010, CSA C390-10, and CSA C747- (incorporated by...
Code of Federal Regulations, 2013 CFR
2013-04-01
.... Each STD shall develop a quality assurance program which will assure that the materials and workmanship... criteria in § 637.207 and be approved by the FHWA. (b) STD capabilities. The STD shall maintain an adequate... qualified sampling and testing personnel employed by the STD or its designated agent. (d) Verification...
Code of Federal Regulations, 2011 CFR
2011-04-01
.... Each STD shall develop a quality assurance program which will assure that the materials and workmanship... criteria in § 637.207 and be approved by the FHWA. (b) STD capabilities. The STD shall maintain an adequate... qualified sampling and testing personnel employed by the STD or its designated agent. (d) Verification...
A Visual Model for the Variance and Standard Deviation
ERIC Educational Resources Information Center
Orris, J. B.
2011-01-01
This paper shows how the variance and standard deviation can be represented graphically by looking at each squared deviation as a graphical object--in particular, as a square. A series of displays show how the standard deviation is the size of the average square.
Inventory of File sref.t03z.pgrb212.spread_3hrly.grib2
ground UGRD analysis U-Component of Wind [m/s] std dev 002 10 m above ground VGRD analysis V-Component of Wind [m/s] std dev 003 1000 mb UGRD analysis U-Component of Wind [m/s] std dev 004 850 mb UGRD analysis U-Component of Wind [m/s] std dev 005 700 mb UGRD analysis U-Component of Wind [m/s] std dev 006 600
Inventory of File sref.t03z.pgrb216.spread_3hrly.grib2
ground UGRD analysis U-Component of Wind [m/s] std dev 002 10 m above ground VGRD analysis V-Component of Wind [m/s] std dev 003 1000 mb UGRD analysis U-Component of Wind [m/s] std dev 004 850 mb UGRD analysis U-Component of Wind [m/s] std dev 005 700 mb UGRD analysis U-Component of Wind [m/s] std dev 006 600
Inventory of File sref.t03z.pgrb243.spread_3hrly.grib2
ground UGRD analysis U-Component of Wind [m/s] std dev 002 10 m above ground VGRD analysis V-Component of Wind [m/s] std dev 003 1000 mb UGRD analysis U-Component of Wind [m/s] std dev 004 850 mb UGRD analysis U-Component of Wind [m/s] std dev 005 700 mb UGRD analysis U-Component of Wind [m/s] std dev 006 600
Inventory of File sref.t03z.pgrb132.spread_3hrly.grib2
ground UGRD analysis U-Component of Wind [m/s] std dev 002 10 m above ground VGRD analysis V-Component of Wind [m/s] std dev 003 1000 mb UGRD analysis U-Component of Wind [m/s] std dev 004 850 mb UGRD analysis U-Component of Wind [m/s] std dev 005 700 mb UGRD analysis U-Component of Wind [m/s] std dev 006 600
NASA Technical Reports Server (NTRS)
Majewicz, Peter; Sampson, Michael
2016-01-01
Describes development and content of a new NASA Standard for Electrical Electronic and Electromechanical (EEE) parts. This Standard reflects current practices, instead of changing them. Most NASA Centers utilize local documents, but there is minimal consistency across the Agency. A gap analysis clearly shows the differences that exist among the different centers and with respect to the NASA Parts Policy. Once approved, the new standard can be referenced in contracts and agreements with organizations outside of NASA.
Martin, Jeffrey D.
2002-01-01
Correlation analysis indicates that for most pesticides and concentrations, pooled estimates of relative standard deviation rather than pooled estimates of standard deviation should be used to estimate variability because pooled estimates of relative standard deviation are less affected by heteroscedasticity. The 2 Variability of Pesticide Detections and Concentrations in Field Replicate Water Samples, 1992–97 median pooled relative standard deviation was calculated for all pesticides to summarize the typical variability for pesticide data collected for the NAWQA Program. The median pooled relative standard deviation was 15 percent at concentrations less than 0.01 micrograms per liter (µg/L), 13 percent at concentrations near 0.01 µg/L, 12 percent at concentrations near 0.1 µg/L, 7.9 percent at concentrations near 1 µg/L, and 2.7 percent at concentrations greater than 5 µg/L. Pooled estimates of standard deviation or relative standard deviation presented in this report are larger than estimates based on averages, medians, smooths, or regression of the individual measurements of standard deviation or relative standard deviation from field replicates. Pooled estimates, however, are the preferred method for characterizing variability because they provide unbiased estimates of the variability of the population. Assessments of variability based on standard deviation (rather than variance) underestimate the true variability of the population. Because pooled estimates of variability are larger than estimates based on other approaches, users of estimates of variability must be cognizant of the approach used to obtain the estimate and must use caution in the comparison of estimates based on different approaches.
Basic life support: evaluation of learning using simulation and immediate feedback devices1.
Tobase, Lucia; Peres, Heloisa Helena Ciqueto; Tomazini, Edenir Aparecida Sartorelli; Teodoro, Simone Valentim; Ramos, Meire Bruna; Polastri, Thatiane Facholi
2017-10-30
to evaluate students' learning in an online course on basic life support with immediate feedback devices, during a simulation of care during cardiorespiratory arrest. a quasi-experimental study, using a before-and-after design. An online course on basic life support was developed and administered to participants, as an educational intervention. Theoretical learning was evaluated by means of a pre- and post-test and, to verify the practice, simulation with immediate feedback devices was used. there were 62 participants, 87% female, 90% in the first and second year of college, with a mean age of 21.47 (standard deviation 2.39). With a 95% confidence level, the mean scores in the pre-test were 6.4 (standard deviation 1.61), and 9.3 in the post-test (standard deviation 0.82, p <0.001); in practice, 9.1 (standard deviation 0.95) with performance equivalent to basic cardiopulmonary resuscitation, according to the feedback device; 43.7 (standard deviation 26.86) mean duration of the compression cycle by second of 20.5 (standard deviation 9.47); number of compressions 167.2 (standard deviation 57.06); depth of compressions of 48.1 millimeter (standard deviation 10.49); volume of ventilation 742.7 (standard deviation 301.12); flow fraction percentage of 40.3 (standard deviation 10.03). the online course contributed to learning of basic life support. In view of the need for technological innovations in teaching and systematization of cardiopulmonary resuscitation, simulation and feedback devices are resources that favor learning and performance awareness in performing the maneuvers.
High fat diet and GLP-1 drugs induce pancreatic injury in mice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rouse, Rodney, E-mail: rodney.rouse@fda.hhs.gov; Xu, Lin; Stewart, Sharron
Glucagon Like Peptide-1 (GLP-1) drugs are currently used to treat type-2 diabetes. Safety concerns for increased risk of pancreatitis and pancreatic ductal metaplasia have accompanied these drugs. High fat diet (HFD) is a type-2 diabetes risk factor that may affect the response to GLP-1 drug treatment. The objective of the present study was to investigate the effects of diet and GLP-1 based drugs on the exocrine pancreas in mice. Experiments were designed in a mouse model of insulin resistance created by feeding a HFD or standard diet (STD) for 6 weeks. The GLP-1 drugs, sitagliptin (SIT) and exenatide (EXE) weremore » administered once daily for additional 6 weeks in both mice fed HFD or STD. The results showed that body weight, blood glucose levels, and serum levels of pro-inflammatory cytokines (TNFα, IL-1β, and KC) were significantly greater in HFD mice than in STD mice regardless of GLP-1 drug treatment. The semi-quantitative grading showed that pancreatic changes were significantly greater in EXE and SIT-treated mice compared to control and that HFD exacerbated spontaneous exocrine pancreatic changes seen in saline-treated mice on a standard diet. Exocrine pancreatic changes identified in this study included acinar cell injury (hypertrophy, autophagy, apoptosis, necrosis, and atrophy), vascular injury, interstitial edema and inflammation, fat necrosis, and duct changes. These findings support HFD as a risk factor to increased susceptibility/severity for acute pancreatitis and indicate that GLP-1 drugs cause pancreatic injury that can be exacerbated in a HFD environment.« less
Blažetić, Senka; Labak, Irena; Viljetić, Barbara; Balog, Marta; Vari, Sandor G.; Krivošíková, Zora; Gajdoš, Martin; Kramárová, Patrícia; Kebis, Anton; Vuković, Rosemary; Puljak, Livia; Has-Schön, Elizabeta; Heffer, Marija
2014-01-01
Aim To evaluate in a rat animal model whether ovariectomy, high fat diet (HFD), and physical activity in the form of running affect leptin receptor (Ob-R) distribution in the brain and white fat tissue compared to sham (Sh) surgery, standard diet (StD), and sedentary conditions. Methods The study included 48 female laboratory Wistar rats (4 weeks old). Following eight weeks of feeding with standard or HFD, rats were subjected to either OVX or Sh surgery. After surgery, all animals continued StD or HFD for the next 10 weeks. During these 10 weeks, ovariectomy and Sh groups were subjected to physical activity or sedentary conditions. Free-floating immunohistochemistry and Western blot methods were carried out to detect Ob-R in the brain and adipose tissue. Results StD-ovariectomy-sedentary group had a greater number of Ob-R positive neurons in lateral hypothalamic nuclei than StD-Sh-sedentary group. There was no difference in Ob-R positive neurons in arcuatus nuclei between all groups. Ob-R distribution in the barrel cortex was higher in HFD group than in StD group. Ob-R presence in perirenal and subcutaneous fat was decreased in StD-ovariectomy group. Conclusion HFD and ovariectomy increased Ob-R distribution in lateral hypothalamic nuclei, but there was no effect on arcuatus nuclei. Our results are first to suggest that HFD, ovariectomy, and physical activity affect Ob-R distribution in the barrel cortex, which might be correlated with the role of Ob-R in election of food in rats. PMID:24891281
Blažetić, Senka; Labak, Irena; Viljetić, Barbara; Balog, Marta; Vari, Sandor G; Krivošíková, Zora; Gajdoš, Martin; Kramárová, Patrícia; Kebis, Anton; Vuković, Rosemary; Puljak, Livia; Has-Schön, Elizabeta; Heffer, Marija
2014-06-01
To evaluate in a rat animal model whether ovariectomy, high fat diet (HFD), and physical activity in the form of running affect leptin receptor (Ob-R) distribution in the brain and white fat tissue compared to sham (Sh) surgery, standard diet (StD), and sedentary conditions. The study included 48 female laboratory Wistar rats (4 weeks old). Following eight weeks of feeding with standard or HFD, rats were subjected to either OVX or Sh surgery. After surgery, all animals continued StD or HFD for the next 10 weeks. During these 10 weeks, ovariectomy and Sh groups were subjected to physical activity or sedentary conditions. Free-floating immunohistochemistry and Western blot methods were carried out to detect Ob-R in the brain and adipose tissue. StD-ovariectomy-sedentary group had a greater number of Ob-R positive neurons in lateral hypothalamic nuclei than StD-Sh-sedentary group. There was no difference in Ob-R positive neurons in arcuatus nuclei between all groups. Ob-R distribution in the barrel cortex was higher in HFD group than in StD group. Ob-R presence in perirenal and subcutaneous fat was decreased in StD-ovariectomy group. HFD and ovariectomy increased Ob-R distribution in lateral hypothalamic nuclei, but there was no effect on arcuatus nuclei. Our results are first to suggest that HFD, ovariectomy, and physical activity affect Ob-R distribution in the barrel cortex, which might be correlated with the role of Ob-R in election of food in rats.
Hogben, Matthew; Hood, Julia; Collins, Dayne; McFarlane, Mary
2013-11-01
Systematic analysis of STD programme data contributes to a national portrait of sexually transmitted disease (STD) prevention activities, including research and evaluation specifically designed to optimise programme efficiency and impact. We analysed the narrative of the 2009 annual progress reports of the US Comprehensive STD Prevention Systems cooperative agreement for 58 STD programmes, concentrating on programme characteristics and partnerships. Programmes described 516 unique partnerships with a median of seven organisations cited per STD programme. Non-profit organisations (including service providers) were most frequently cited. Higher gonorrhoea morbidity was associated with reporting more partnerships; budget problems were associated with reporting fewer. Challenges to engaging in partnerships included budget constraints, staff turnover and low interest. Data provide a source of information for judging progress in programme collaboration and for informing a sustained programme-focused research and evaluation agenda.
Determinants of STD epidemics: implications for phase appropriate intervention strategies.
Aral, S O
2002-04-01
Determinants of evolving epidemics of sexually transmitted diseases (STD) are equally influenced by the evolution of the STD epidemics themselves and by the evolution of human societies. A temporal approach to STD transmission dynamics suggests the need to monitor infectivity, rate of exposure between infected and susceptible individuals, and duration of infectiousness in societies. Different indicators may be used to monitor rate of exposure in the general population and in core groups. In addition, underlying determinants of STD epidemics such as poverty, inequality, racial/ethnic discrimination, unemployment, sex ratio, volume of migration, and health care coverage and quality are important variables to monitor through a surveillance system focused on social context. Ongoing large scale societal changes including urbanisation, globalisation, increasing inequality, and increasing volume of migrant populations may affect the evolution of STD epidemics. Globalised STD epidemics could pose a major challenge to local public health systems.
Telemetry Standards, RCC Standard 106-17. Chapter 9. Telemetry Attributes Transfer Standard
2017-07-01
or the direct recorder track/ channel MIL-STD-1553 or ARINC 429 bus format characteristics. (4) Message Data Attributes: Specifies the message...R group to the P group is from the Channel Data Link Name (R) to the Data Link Name (P). g. The tie from the R group to the B group is from the... Channel Data Link Name or Sub- Channel Name (R) to the Data Link Name (B). h. The tie from the R group to the Message Data group (S) is from the Channel
23 CFR 635.116 - Subcontracting and contractor responsibilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... provisions. (b) The STD shall not permit any of the contract work to be performed under a subcontract, unless such arrangement has been authorized by the STD in writing. Prior to authorizing a subcontract, the STD... and requirements of the prime contract. The Division Administrator may permit the STD to satisfy the...
23 CFR 635.116 - Subcontracting and contractor responsibilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... provisions. (b) The STD shall not permit any of the contract work to be performed under a subcontract, unless such arrangement has been authorized by the STD in writing. Prior to authorizing a subcontract, the STD... and requirements of the prime contract. The Division Administrator may permit the STD to satisfy the...
23 CFR 635.116 - Subcontracting and contractor responsibilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... provisions. (b) The STD shall not permit any of the contract work to be performed under a subcontract, unless such arrangement has been authorized by the STD in writing. Prior to authorizing a subcontract, the STD... and requirements of the prime contract. The Division Administrator may permit the STD to satisfy the...
23 CFR 635.116 - Subcontracting and contractor responsibilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... provisions. (b) The STD shall not permit any of the contract work to be performed under a subcontract, unless such arrangement has been authorized by the STD in writing. Prior to authorizing a subcontract, the STD... and requirements of the prime contract. The Division Administrator may permit the STD to satisfy the...
Reportable STDs in Young People 15-24 Years of Age, by State
... STD 101 in a Box Home Script for Sex in the City Video STD Clinical Slides STD Clinical Slides STD Picture ... include: line graphs by year; pie charts for sex; bar charts by state and country; bar charts for age, race/ethnicity, and transmission ... Quicktime file RealPlayer file Text file ...
Kövér, Katalin E; Wéber, Edit; Martinek, Tamás A; Monostori, Eva; Batta, Gyula
2010-10-18
Saturation transfer difference (STD) is a valuable tool for studying the binding of small molecules to large biomolecules and for obtaining detailed information on the binding epitopes. Here, we demonstrate that the proposed (15)N/(13)C variants of group-selective, "GS-STD" experiments provide a powerful approach to mapping the binding epitope of a ligand even in the absence of efficient spin diffusion within the target protein. Therefore, these experimental variants broaden the scope of STD studies to smaller and/or more-dynamic targets. The STD spectra obtained in four different experimental setups (selective (1)H STD, (15)N GS-STD, (13)C(Ar) and (13)C(aliphatic) GS-STD approaches) revealed that the signal-intensity pattern of the difference spectra is affected by both the type and the spatial distribution of the excited "transmitter" atoms, as well as by the efficiency of the spin-diffusion-mediated magnetization transfer. The performance of the experiments is demonstrated on a system by using the lectin, galectin-1 and its carbohydrate ligand, lactose.
JSC Design and Procedural Standards, JSC-STD-8080
NASA Technical Reports Server (NTRS)
Punch, Danny T.
2011-01-01
This document provides design and procedural requirements appropriate for inclusion in specifications for any human spaceflight program, project, spacecraft, system, or end item. The term "spacecraft" as used in the standards includes launch vehicles, orbital vehicles, non-terrestrial surface vehicles, and modules. The standards are developed and maintained as directed by Johnson Space Center (JSC) Policy Directive JPD 8080.2, JSC Design and Procedural Standards for Human Space Flight Equipment. The Design and Procedural Standards contained in this manual represent human spacecraft design and operational knowledge applicable to a wide range of spaceflight activities. These standards are imposed on JSC human spaceflight equipment through JPD 8080.2. Designers shall comply with all design standards applicable to their design effort.
Patel, Pragna; Bush, Tim; Mayer, Kenneth; Milam, Joel; Richardson, Jean; Hammer, John; Henry, Keith; Overton, Turner; Conley, Lois; Marks, Gary; Brooks, John T
2012-06-01
We evaluated whether routine biannual sexually transmitted disease (STD) testing coupled with brief risk-reduction counseling reduces STD incidence and high-risk behaviors. The SUN study is a prospective observational HIV cohort study conducted in 4 US cities. At enrollment and every 6 months thereafter, participants completed a behavioral survey and were screened for STDs, and if diagnosed, were treated. Medical providers conducted brief risk-reduction counseling with all patients. Among men who have sex with men (MSM), we examined trends in STD incidence and rates of self-reported risk behaviors before and after exposure to the risk-reduction intervention. The "preintervention" visit was the study visit that was at least 6 months after enrollment STD screening and treatment and at which the participant was first exposed to the intervention. The "postintervention" visit was 12 months later. Among 216 MSM with complete STD and behavioral data, median age was 44.5 years; 77% were non-Hispanic white; 83% were on highly active antiretroviral treatment; 84% had an HIV RNA level <400 copies/mL and the median CD4 (cluster of differentiation 4) count was 511 cells/mm. Twelve months after first exposure to the risk-reduction intervention, STD incidence declined from 8.8% to 4.2% (P = 0.041). Rates of unprotected receptive or insertive anal intercourse with HIV-positive partners increased (19% to 25%, P = 0.024), but did not change with HIV-negative partners or partners of unknown HIV status (24% to 22%, P = 0.590). STD incidence declined significantly among HIV-infected MSM after implementing frequent, routine STD testing coupled with risk-reduction counseling. These findings support adoption of routine STD screening and risk-reduction counseling for HIV-infected MSM.
NASA Astrophysics Data System (ADS)
Lacher, Larissa; Lohmann, Ulrike; Boose, Yvonne; Zipori, Assaf; Herrmann, Erik; Bukowiecki, Nicolas; Steinbacher, Martin; Kanji, Zamin A.
2017-12-01
In this work we describe the Horizontal Ice Nucleation Chamber (HINC) as a new instrument to measure ambient ice-nucleating particle (INP) concentrations for conditions relevant to mixed-phase clouds. Laboratory verification and validation experiments confirm the accuracy of the thermodynamic conditions of temperature (T) and relative humidity (RH) in HINC with uncertainties in T of ±0.4 K and in RH with respect to water (RHw) of ±1.5 %, which translates into an uncertainty in RH with respect to ice (RHi) of ±3.0 % at T > 235 K. For further validation of HINC as a field instrument, two measurement campaigns were conducted in winters 2015 and 2016 at the High Altitude Research Station Jungfraujoch (JFJ; Switzerland, 3580 m a. s. l. ) to sample ambient INPs. During winters 2015 and 2016 the site encountered free-tropospheric conditions 92 and 79 % of the time, respectively. We measured INP concentrations at 242 K at water-subsaturated conditions (RHw = 94 %), relevant for the formation of ice clouds, and in the water-supersaturated regime (RHw = 104 %) to represent ice formation occurring under mixed-phase cloud conditions. In winters 2015 and 2016 the median INP concentrations at RHw = 94 % was below the minimum detectable concentration. At RHw = 104 %, INP concentrations were an order of magnitude higher, with median concentrations in winter 2015 of 2.8 per standard liter (std L-1; normalized to standard T of 273 K and pressure, p, of 1013 hPa) and 4.7 std L-1 in winter 2016. The measurements are in agreement with previous winter measurements obtained with the Portable Ice Nucleation Chamber (PINC) of 2.2 std L-1 at the same location. During winter 2015, two events caused the INP concentrations at RHw = 104 % to significantly increase above the campaign average. First, an increase to 72.1 std L-1 was measured during an event influenced by marine air, arriving at the JFJ from the North Sea and the Norwegian Sea. The contribution from anthropogenic or other sources can thereby not be ruled out. Second, INP concentrations up to 146.2 std L-1 were observed during a Saharan dust event. To our knowledge this is the first time that a clear enrichment in ambient INP concentration in remote regions of the atmosphere is observed during a time of marine air mass influence, suggesting the importance of marine particles on ice nucleation in the free troposphere.
The other STDs. Linked with HIV transmission, they are attracting new attention.
Lande, R E
1992-12-01
Health officials began neglecting sexually transmitted diseases (STDs) (syphilis, gonorrhea, chlamydia, trichomoniasis, and chancroid) when the AIDS epidemic began. They now refocus efforts on STDs because data indicate that STDs facilitate HIV transmission. Even though the risk of HIV transmission is lower in people with nonulcerative STDs than those with genital ulcers (0-4 vs. 2-5 times), the link between nonulcerative STDs and HIV transmission is a greater problem since nonulcerative STD cases occur more often than genital ulcers. Many AIDS control programs execute STD control activities. Countries must improve existing STD control programs. They should strengthen STD surveillance. Viet Nam has established surveillance sites at STD clinics in 4 cities. Training different health providers in STD control would make STD services accessible to more people. These providers include nurses, midwives, pharmacists, and even traditional healers and should be based at pharmacies and primary health care, maternal and child health, and family planning clinics. Primary health care workers should use symptoms to diagnose and treat STDs rather than laboratory tests. 1 drawback of this syndromic approach is that about 50% of women do not exhibit STD symptoms. STD control programs must guarantee a steady reserve of drugs. In Zimbabwe, primary health clinics receive STD drugs from a decentralized drug distribution system (5-8 warehouses) rather than the older centralized system (1 warehouse). This has reduced the waiting time from 6 months to 4-6 weeks. Programs need to encourage individuals to seek early treatment of STDs via health education campaigns (e.g., mass media), outreach to high risk groups such as prostitutes and the patron, and contact tracing. STD counselors should promote condom use. An STD program in Nairobi, Kenya informs patients to use a condom during sex with any causal sex partner, shows patients how to put on and take off the condom, and tells them where they can obtain condoms.
Szczepina, Monica G; Bleile, Dustin W; Pinto, B Mario
2011-10-04
Saturation transfer difference (STD)-NMR spectroscopy was used to probe experimentally the bioactive solution conformation of the carbohydrate mimic MDWNMHAA 1 of the O-polysaccharide of Shigella flexneri Y when bound to its complementary antibody, mAb SYA/J6. Molecular dynamics simulations using the ZymeCAD™ Molecular Dynamics platform were also undertaken to give a more accurate picture of the conformational flexibility and the possibilities for bound ligand conformations. The ligand topology, or the dynamic epitope, was mapped with the CORCEMA-ST (COmplete Relaxation and Conformational Exchange Matrix Analysis of Saturation Transfer) program that calculates a total matrix analysis of relaxation and exchange effects to generate predicted STD-NMR intensities from simulation. The comparison of these predicted STD enhancements with experimental data was used to select a representative binding mode. A protocol that employed theoretical STD effects calculated at snapshots during the entire course of a molecular dynamics (MD) trajectory of the peptide bound to the Fv portion of the antibody, and not the averaged atomic positions of receptor-ligand complexes, was also examined. In addition, the R factor was calculated on the basis of STD (fit) to avoid T1 bias, and an effective R factor, R(eff), was defined such that if the calculated STD (fit) for proton k was within error of the experimental STD (fit) for proton k, then that calculated STD (fit) for proton k was not included in the calculation of the R factor. This protocol was effective in deriving the antibody-bound solution conformation of the peptide which also differed from the bound conformation determined by X-ray crystallography; however, several discrepancies between experimental and calculated STD (fit) values were observed. The bound conformation was therefore further refined with a simulated annealing refinement protocol known as STD-NMR intensity-restrained CORCEMA optimization (SICO) to give a more accurate representation of the bound peptide epitope. Further optimization was required in this case, but a satisfactory correlation between experimental and calculated STD values was obtained. Attempts were also made to obtain STD enhancements with a synthetic pentasaccharide hapten, corresponding to the O-polysaccharide, while bound to the antibody. However, unfavorable kinetics of binding in this system prevented sufficient STD build-up, which, in turn, hindered a rigorous analysis via full STD build-up curves. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Fabrication and Characterization of Blue Organic Light-emitting Diodes
2011-09-01
Unclassified 19b. TELEPHONE NUMBER (Include area code) (301) 394-1473 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents...sure the CFx gas valve is off and that the oxygen valve is open (counterclockwise) all the way. b. Load the substrates into chamber, ITO-side up
Simulation of Dual Firing of Hydrogen and JP-8 in a Swirling Combustor
2012-06-14
completed using the Ansys CFX computational fluid dynamics software. The total Lower Heating Value of the fuel mixture is maintained at a constant 6 kW...PERSON a. REPORT unclassified b. ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-01
... prices will likely be forecasted using trends from the Energy Information Administration's most recent... forecasted energy prices, using shipment projections and average energy efficiency projections. DOE... DEPARTMENT OF ENERGY 10 CFR Part 431 [Docket No. EERE-2013-BT-STD-0007] RIN 1904-AC95 Energy...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-12
... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket No. EERE-2011-BT-STD-0047] RIN 1904-AC56 Energy Conservation Program for Consumer Products and Certain Commercial and Industrial Equipment: Energy Conservation Standards for Direct Heating Equipment AGENCY: Office of Energy Efficiency and Renewable Energy, Department...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-18
... diameter, elliptical reflector (ER), and bulged reflector (BR) incandescent reflector lamps. In that... document or any other aspect of the rulemaking for certain small diameter, ER, and BR incandescent..., ER, and BR incandescent reflector lamps, and provide docket number EERE-2010- BT-STD-0005 and/or RIN...
2007-06-01
THIS PAGE INTENTIONALLY LEFT BLANK i NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. 239-18...4 I . INTRODUCTION............................................................................................. 7 A. SCOPE...6 THIS PAGE INTENTIONALLY LEFT BLANK 7 I . INTRODUCTION A. SCOPE The intent
Building Multilevel Secure Web Services-Based Components for the Global Information Grid
2006-05-01
unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Transforming: Business , Security ,Warfighting 16 CROSSTALK The Journal of Defense...A Single Step of the BAC Table 1: A Single Step of the Block Access Controller Transforming: Business , Security ,Warfighting 18 CROSSTALK The Journal
AGOR 28: SIO Shipyard Representative Bi-Weekly Progress Report
2015-08-25
DCI was not able to obtain the FDA Certificate of Sanitation for Armstrong because the sewage discharge is ahead of the water maker suction. The...unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 is to move the sewage discharge aft of the
Testing New Survey Questions of Sexual Harassment and Sexual Assault
2011-01-01
Technical Report No. 100-11 REPORT DOCUMENTATION PAGE Standard Form 298 (Rev. 8 /98) Prescribed by ANSI Std. Z39.18 Form Approved OMB No. 0704...S) AND ADDRESS(ES) 8 . PERFORMING ORGANIZATION REPORT NUMBER 10. SPONSOR/MONITOR’S ACRONYM(S) 11. SPONSOR/MONITOR’S REPORT NUMBER(S) 9... 8 Conclusion
Targeting Autophagy for the Treatment of TSC and LAM
2013-10-01
UU 5 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 Page 3 of 5 Table...and consent form. Summary of Amendment 04 A spirometry measurement was added to visit 6 Urinalysis was included in visit 6 Urine pregnancy
Non-Linear Stability of Magnetically Focused Particle Beams
2008-11-30
PROJECT NUMBER N/A 5e. TASK NUMBER N/A 5f. WORK UNIT NUMBER N/A 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Instituto de Fisica ...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 Felipe Barbedo Rizzato Institute de Fisica , Universidade Federal do Rio Grande do Sul
Military Standard Common APSE (Ada Programming Support Environment) Interface Set (CAIS).
1985-01-01
QUEUEASE. LAST-KEY (QUEENAME) . LASTREI.TIONI(QUEUE-NAME). FILE-NODE. PORN . ATTRIBUTTES. ACCESSCONTROL. LEVEL); CLOSE (QUEUE BASE); CLOSE(FILE NODE...PROPOSED XIIT-STD-C.4 31 J NNUAfY logs procedure zTERT (ITERATOR: out NODE ITERATON; MAMIE: NAME STRING.KIND: NODE KID : KEY : RELATIONSHIP KEY PA1TTE1 :R
40 CFR 89.207 - Credit calculation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Trading Provisions § 89.207 Credit calculation. (a) Requirements for calculating NO X credits from Tier 1...) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard...) of this section, to be applied to Tier 1 NOX credits to be banked or traded for determining...
The Effects of Turbulence on Tthe Measurements of Five-Hole Probes
NASA Astrophysics Data System (ADS)
Diebold, Jeffrey Michael
The primary goals of this research were to quantify the effects of turbulence on the measurements of five-hole pressure probes (5HP) and to develop a model capable of predicting the response of a 5HP to turbulence. The five-hole pressure probe is a commonly used device in experimental fluid dynamics and aerodynamics. By measuring the pressure at the five pressure ports located on the tip of the probe it is possible to determine the total pressure, static pressure and the three components of velocity at a point in the flow. Previous research has demonstrated that the measurements of simple pressure probes such as Pitot probes are significantly influenced by the presence of turbulence. Turbulent velocity fluctuations contaminate the measurement of pressure due to the nonlinear relationship between pressure and velocity as well as the angular response characteristics of the probe. Despite our understanding of the effects of turbulence on Pitot and static pressure probes, relatively little is known about the influence of turbulence on five-hole probes. This study attempts to fill this gap in our knowledge by using advanced experimental techniques to quantify these turbulence-induced errors and by developing a novel method of predicting the response of a five-hole probe to turbulence. A few studies have attempted to quantify turbulence-induced errors in five-hole probe measurements but they were limited by their inability to accurately measure the total and static pressure in the turbulent flow. The current research utilizes a fast-response five-hole probe (FR5HP) in order to accurately quantify the effects of turbulence on different standard five-hole probes (Std5HP). The FR5HP is capable of measuring the instantaneous flowfield and unlike the Std5HP the FR5HP measurements are not contaminated by the turbulent velocity fluctuations. Measurements with the FR5HP and two different Std5HPs were acquired in the highly turbulent wakes of 2D and 3D cylinders in order to quantify the turbulence-induced errors in Std5HP measurements. The primary contribution of this work is the development and validation of a simulation method to predict the measurements of a Std5HP in an arbitrary turbulent flow. This simulation utilizes a statistical approach to estimating the pressure at each port on the tip of the probe. The angular response of the probe is modeled using experimental calibration data for each five-hole probe. The simulation method is validated against the experimental measurements of the Std5HPs, and then used to study the how the characteristics of the turbulent flowfield influence the measurements of the Std5HPs. It is shown that total pressure measured by a Std5HP is increased by axial velocity fluctuations but decreased by the transverse fluctuations. The static pressure was shown to be very sensitive to the transverse fluctuations while the axial fluctuations had a negligible effect. As with Pitot probes, the turbulence-induced errors in the Std5HPs measurements were dependent on both the properties of the turbulent flow and the geometry of the probe tip. It is then demonstrated that this simulation method can be used to correct the measurements of a Std5HP in a turbulent flow if the characteristics of the turbulence are known. Finally, it is demonstrated that turbulence-induced errors in Std5HP measurements can have a substantial effect on the determination of the profile and vortex-induced drag from measurements in the wake of a 3D body. The results showed that while the calculation of both drag components was influenced by turbulence-induced errors the largest effect was on the determination of vortex-induced drag.
MFC Communications Infrastructure Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michael Cannon; Terry Barney; Gary Cook
2012-01-01
Unprecedented growth of required telecommunications services and telecommunications applications change the way the INL does business today. High speed connectivity compiled with a high demand for telephony and network services requires a robust communications infrastructure. The current state of the MFC communication infrastructure limits growth opportunities of current and future communication infrastructure services. This limitation is largely due to equipment capacity issues, aging cabling infrastructure (external/internal fiber and copper cable) and inadequate space for telecommunication equipment. While some communication infrastructure improvements have been implemented over time projects, it has been completed without a clear overall plan and technology standard.more » This document identifies critical deficiencies with the current state of the communication infrastructure in operation at the MFC facilities and provides an analysis to identify needs and deficiencies to be addressed in order to achieve target architectural standards as defined in STD-170. The intent of STD-170 is to provide a robust, flexible, long-term solution to make communications capabilities align with the INL mission and fit the various programmatic growth and expansion needs.« less
NASA Astrophysics Data System (ADS)
Pedersen, Mads Møller; Pihl, Michael Johannes; Haugaard, Per; Hansen, Jens Munk; Lindskov Hansen, Kristoffer; Bachmann Nielsen, Michael; Jensen, Jørgen Arendt
2011-03-01
Spectral velocity estimation is considered the gold standard in medical ultrasound. Peak systole (PS), end diastole (ED), and resistive index (RI) are used clinically. Angle correction is performed using a flow angle set manually. With Transverse Oscillation (TO) velocity estimates the flow angle, peak systole (PSTO), end diastole (EDTO), and resistive index (RITO) are estimated. This study investigates if these clinical parameters are estimated equally good using spectral and TO data. The right common carotid arteries of three healthy volunteers were scanned longitudinally. Average TO flow angles and std were calculated { 52+/-18 ; 55+/-23 ; 60+/-16 }°. Spectral angles { 52 ; 56 ; 52 }° were obtained from the B-mode images. Obtained values are: PSTO { 76+/-15 ; 89+/-28 ; 77+/-7 } cm/s, spectral PS { 77 ; 110 ; 76 } cm/s, EDTO { 10+/-3 ; 14+/-8 ; 15+/-3 } cm/s, spectral ED { 18 ; 13 ; 20 } cm/s, RITO { 0.87+/-0.05 ; 0.79+/-0.21 ; 0.79+/-0.06 }, and spectral RI { 0.77 ; 0.88 ; 0.73 }. Vector angles are within +/-two std of the spectral angle. TO velocity estimates are within +/-three std of the spectral estimates. RITO are within +/-two std of the spectral estimates. Preliminary data indicates that the TO and spectral velocity estimates are equally good. With TO there is no manual angle setting and no flow angle limitation. TO velocity estimation can also automatically handle situations where the angle varies over the cardiac cycle. More detailed temporal and spatial vector estimates with diagnostic potential are available with the TO velocity estimation.
2008-06-13
technology developments. 2. This new-issue SMC standard comprises the text of The Aerospace Corporation report number TOR-2005( 8583 )-1. 3...issues of the documents are the current versions. 1. Aerospace Report No. TOR-2005( 8583 )-2, Electrical Power Systems, Direct Current, Space Vehicle...Design Requirements, The Aerospace Corp., 13 January 2005. 2. Aerospace Report No. TR-2004( 8583 )-1 (proposed MIL-STD-1540E), Test Requirements for
2016-12-01
2016 Dissertation Supervisors: Wieslaw Maslowski John Colosi THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved...level is 4% of the standard GM value. Frequency spectra of spice show a form similar to the internal-wave spectra but with a steeper spectral slope...Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. 239-18 ii THIS PAGE INTENTIONALLY LEFT BLANK iii Approved for public release
Anomaly Detection for Data Reduction in an Unattended Ground Sensor (UGS) Field
2014-09-01
information (shown with solid lines in the diagram). Typically, this would be a mobile ad - hoc network (MANET). The clusters are connected to other nodes...interquartile ranges MANET mobile ad - hoc network OSUS Open Standards for Unattended Sensors TOC tactical operations center UAVs unmanned aerial vehicles...19b. TELEPHONE NUMBER (Include area code ) 301-394-1221 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents List of
Selected Issues in DoD’s Radio Frequency Identification (RFID) Implementation
2006-04-01
Evaluation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 10 GHz, used in Electronic...standard for human exposure to RF Signal, 3 kHz-300 GHz BS EN 50364 Limitation of human exposure to electromagnetic fields from devices operating in the...Management and DoD Explosives Safety Board, and DoDD 6055.9-STD, DoD Ammunition and Explosives Safety Standards. Exposure of people to electromagnetic
2013-04-01
Measurement Tracking System (SAINT) with an advanced hand-held, time-domain electromagnetic sensor (TEM-HH) and document classification performance at...rejecting 77% of the clutter. 15. SUBJECT TERMS EMI, electromagnetic induction, UXO classification, UXO, IMU, inertial measurement unit, 16. SECURITY...U c. THIS PAGE U UU 19b. TELEPHONE NUMBER (include area code) 919-677-1560 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18
New Standard Weir Design for Dredged Material Management Area, Jacksonville District
2014-08-01
dock access, Bartram Island Cell B2, Jacksonville, Florida. Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 ERDC/TN DOTS-14-01 August 2014 2 US Army Corps of Engineers • Engineer Research...and through the riser stack of weir boards. This requires secondary sealing measures in the form of plastic sheeting, geotextiles, and/or burlap
Development of Medical Technology for Contingency Response to Marrow Toxic Agents
2013-01-31
REPORT NUMBER N/A collaboration and data Standard Form 298 (Rev. 8-98) Prescribed by ANSI-Std Z39-l8 1 of 20 Grant Award N00014-12-1-0142...Closed 4 IIA.2 Objective 2 – Coordination of Care of Casualties Task 1 – Contingency Response Network Open 4 Task 2 – Standard Operating...manuscript Biosecurity and Bioterrorism: Biodefense Strategy, Practice, and Science entitled,” Medical planning and response for a nuclear detonation: a
Defining Medical Levels of Care for Exploration Missions
NASA Technical Reports Server (NTRS)
Hailey, M.; Reyes, D.; Urbina, M.; Rubin, D.; Antonsen, E.
2017-01-01
NASA medical care standards establish requirements for providing health and medical programs for crewmembers during all phases of a mission. These requirements are intended to prevent or mitigate negative health consequences of long-duration spaceflight, thereby optimizing crew health and performance over the course of the mission. Current standards are documented in the two volumes of the NASA-STD-3001 Space Flight Human-System Standard document, established by the Office of the Chief Health and Medical Officer. Its purpose is to provide uniform technical standards for the design, selection, and application of medical hardware, software, processes, procedures, practices, and methods for human-rated systems. NASA-STD-3001 Vol. 1 identifies five levels of care for human spaceflight. These levels of care are accompanied by several components that illustrate the type of medical care expected for each. The Exploration Medical Capability (ExMC) of the Human Research Program has expanded the context of these provided levels of care and components. This supplemental information includes definitions for each component of care and example actions that describe the type of capabilities that coincide with the definition. This interpretation is necessary in order to fully and systematically define the capabilities required for each level of care in order to define the medical requirements and plan for infrastructure needed for medical systems of future exploration missions, such as one to Mars.
The Relationship between STD Locus of Control and STD Acquisition among Adolescent Girls.
ERIC Educational Resources Information Center
Rosenthal, Susan L.; Griffith, Jennifer O.; Succop, Paul A.; Biro, Frank M.; Lewis, Lisa M.; DeVellis, Robert F.; Stanberry, Lawrence R.
2002-01-01
Adolescent girls from an urban-based clinic participated in a longitudinal study about psychosexual development and risk of STD acquisition. The girls were asked about their perceptions of loci of control (parents, internal control) as it relates to STD acquisition. Responses to locus of control correlated over time but variations were not found…
23 CFR 635.114 - Award of contract and concurrence in award.
Code of Federal Regulations, 2014 CFR
2014-04-01
... STD in accordance with § 635.110. Award shall be within the time established by the STD and subject to the prior concurrence of the Division Administrator. (b) The STD shall formally request concurrence by.... (c) Following the opening of bids, the STD shall examine the unit bid prices of the apparent low bid...
23 CFR 710.603 - Direct Federal acquisition.
Code of Federal Regulations, 2011 CFR
2011-04-01
... the STD to commence right-of-way acquisition, the date of the project agreement and a statement that... negotiations which have been conducted by the STD with landowners; (9) An agreement that the STD will pay its... required by State law any time before the FHWA makes a determination that the STD is unable to acquire the...
23 CFR 635.114 - Award of contract and concurrence in award.
Code of Federal Regulations, 2013 CFR
2013-04-01
... STD in accordance with § 635.110. Award shall be within the time established by the STD and subject to the prior concurrence of the Division Administrator. (b) The STD shall formally request concurrence by.... (c) Following the opening of bids, the STD shall examine the unit bid prices of the apparent low bid...
23 CFR 635.114 - Award of contract and concurrence in award.
Code of Federal Regulations, 2011 CFR
2011-04-01
... STD in accordance with § 635.110. Award shall be within the time established by the STD and subject to the prior concurrence of the Division Administrator. (b) The STD shall formally request concurrence by.... (c) Following the opening of bids, the STD shall examine the unit bid prices of the apparent low bid...
23 CFR 635.114 - Award of contract and concurrence in award.
Code of Federal Regulations, 2012 CFR
2012-04-01
... STD in accordance with § 635.110. Award shall be within the time established by the STD and subject to the prior concurrence of the Division Administrator. (b) The STD shall formally request concurrence by.... (c) Following the opening of bids, the STD shall examine the unit bid prices of the apparent low bid...
23 CFR 710.603 - Direct Federal acquisition.
Code of Federal Regulations, 2013 CFR
2013-04-01
... the STD to commence right-of-way acquisition, the date of the project agreement and a statement that... negotiations which have been conducted by the STD with landowners; (9) An agreement that the STD will pay its... required by State law any time before the FHWA makes a determination that the STD is unable to acquire the...
23 CFR 710.603 - Direct Federal acquisition.
Code of Federal Regulations, 2014 CFR
2014-04-01
... the STD to commence right-of-way acquisition, the date of the project agreement and a statement that... negotiations which have been conducted by the STD with landowners; (9) An agreement that the STD will pay its... required by State law any time before the FHWA makes a determination that the STD is unable to acquire the...
Estimated Probability of a Cervical Spine Injury During an ISS Mission
NASA Technical Reports Server (NTRS)
Brooker, John E.; Weaver, Aaron S.; Myers, Jerry G.
2013-01-01
Introduction: The Integrated Medical Model (IMM) utilizes historical data, cohort data, and external simulations as input factors to provide estimates of crew health, resource utilization and mission outcomes. The Cervical Spine Injury Module (CSIM) is an external simulation designed to provide the IMM with parameter estimates for 1) a probability distribution function (PDF) of the incidence rate, 2) the mean incidence rate, and 3) the standard deviation associated with the mean resulting from injury/trauma of the neck. Methods: An injury mechanism based on an idealized low-velocity blunt impact to the superior posterior thorax of an ISS crewmember was used as the simulated mission environment. As a result of this impact, the cervical spine is inertially loaded from the mass of the head producing an extension-flexion motion deforming the soft tissues of the neck. A multibody biomechanical model was developed to estimate the kinematic and dynamic response of the head-neck system from a prescribed acceleration profile. Logistic regression was performed on a dataset containing AIS1 soft tissue neck injuries from rear-end automobile collisions with published Neck Injury Criterion values producing an injury transfer function (ITF). An injury event scenario (IES) was constructed such that crew 1 is moving through a primary or standard translation path transferring large volume equipment impacting stationary crew 2. The incidence rate for this IES was estimated from in-flight data and used to calculate the probability of occurrence. The uncertainty in the model input factors were estimated from representative datasets and expressed in terms of probability distributions. A Monte Carlo Method utilizing simple random sampling was employed to propagate both aleatory and epistemic uncertain factors. Scatterplots and partial correlation coefficients (PCC) were generated to determine input factor sensitivity. CSIM was developed in the SimMechanics/Simulink environment with a Monte Carlo wrapper (MATLAB) used to integrate the components of the module. Results: The probability of generating an AIS1 soft tissue neck injury from the extension/flexion motion induced by a low-velocity blunt impact to the superior posterior thorax was fitted with a lognormal PDF with mean 0.26409, standard deviation 0.11353, standard error of mean 0.00114, and 95% confidence interval [0.26186, 0.26631]. Combining the probability of an AIS1 injury with the probability of IES occurrence was fitted with a Johnson SI PDF with mean 0.02772, standard deviation 0.02012, standard error of mean 0.00020, and 95% confidence interval [0.02733, 0.02812]. The input factor sensitivity analysis in descending order was IES incidence rate, ITF regression coefficient 1, impactor initial velocity, ITF regression coefficient 2, and all others (equipment mass, crew 1 body mass, crew 2 body mass) insignificant. Verification and Validation (V&V): The IMM V&V, based upon NASA STD 7009, was implemented which included an assessment of the data sets used to build CSIM. The documentation maintained includes source code comments and a technical report. The software code and documentation is under Subversion configuration management. Kinematic validation was performed by comparing the biomechanical model output to established corridors.
Fernandez, Carla; Kaschke, Imke; Perlman, Steven; Koehler, Bjoern; Marks, Luc
2015-11-01
Special Olympics athletes, as part of the population with intellectual disabilities, are reported to be more vulnerable to dental injuries due to poor lip closure, slow response to environmental obstacles, oral pathologic reflexes, or dental features. The aim of this study was to assess the prevalence of dental trauma among Special Olympics athletes in countries of Europe and Eurasia. A retrospective longitudinal study was performed with data collected through standardized Special Smiles screening forms and procedures from consenting 15,941 athletes participating in the annual Special Olympics held in 49 countries from Europe and Eurasia between 2007 and 2012. The data was compiled in an Excel worksheet and transferred to an SPSS data file in order to be analyzed. A total of 2190 athletes presented dental injury (13.02%) with a std. deviation of 5.02%, and there were no significant differences (p = 0.136) in mean dental injury between age groups (one-way ANOVA test). The present data suggest that dental trauma is an actual problem among individuals with special needs. The distribution of prevalence among the different countries had a remarkable variability, but it is evident that a relatively high proportion of this population is in need of dental trauma preventive programs.
NASA Astrophysics Data System (ADS)
Wang, X.; Zhang, P.; Sun, Z.
2018-04-01
Interferometric synthetic aperture radar(InSAR), as a space geodetictechnology, had been testified a high potential means of earth observation providing a method fordigital elevation model (DEM) and surface deformation monitoring of high precision. However, the accuracy of the interferometric synthetic aperture radar is mainly limited by the effects of atmospheric water vapor. In order to effectively measure topography or surface deformations by synthetic aperture radar interferometry (InSAR), it is necessary to mitigate the effects of atmospheric water vapor on the interferometric signals. This paper analyzed the atmospheric effects on the interferogram quantitatively, and described a result of estimating Precipitable Water Vapor (PWV) from the the Medium Resolution Imaging Spectrometer (MERIS), Moderate Resolution Imaging Spectroradiometer (MODIS) and the ground-based GPS, compared the MERIS/MODIS PWV with the GPS PWV. Finally, a case study for mitigating atmospheric effects in interferogramusing with using the integration of MERIS and MODIS PWV overSouthern California is given. The result showed that such integration approach benefits removing or reducing the atmospheric phase contribution from the corresponding interferogram, the integrated Zenith Path Delay Difference Maps (ZPDDM) of MERIS and MODIS helps reduce the water vapor effects efficiently, the standard deviation (STD) of interferogram is improved by 23 % after the water vapor correction than the original interferogram.
Comparison of clients of a mobile health van and a traditional STD clinic.
Ellen, Jonathan M; Bonu, Sekhar; Arruda, Jaime S; Ward, Michael A; Vogel, Ruth
2003-04-01
The objective of this study was to determine if there were any demographic, behavioral, and clinical differences between clients seen aboard a mobile sexually transmitted disease (STD)/HIV clinic compared with those seen in a traditional municipal STD/HIV health clinic for receipt of STD/HIV services. Clients seen in the two different settings were interviewed about demographic characteristics, reasons for their visit, STD history, their HIV/STD risk factors, and the risk factors of their sex partners. Clients in both settings were also offered testing for syphilis, gonorrhea, chlamydia, and HIV. Results suggested that clients seen at the mobile clinic were older, more likely to be injecting drug users themselves and/or to have sex partners who were, or had engaged in prostitution for money or drugs. Over half (54.4%) of the mobile clinic clients sought testing for HIV, and they were far less likely to be seeking care for symptoms of an STD. In contrast, only 7.1% of municipal clinic clients indicated HIV testing as the reason for their visit, whereas nearly two thirds (64.5%) reported symptoms of disease. Two percent of municipal clinic clients and 5.4% of mobile clinic clients had a positive HIV test ( p<.001), and 17.8% of STD clinic clients and 5.6% of mobile van clients had a positive gonorrhea and/or test ( p<.001). These data suggest that a mobile STD/HIV clinic may be an effective strategy to reach individuals at high risk for HIV who are not being served by traditional municipal STD/HIV health clinics.
ERIC Educational Resources Information Center
Rasberry, Catherine N.; Liddon, Nicole; Adkins, Susan Hocevar; Lesesne, Catherine A.; Hebert, Andrew; Kroupa, Elizabeth; Rose, India D.; Morris, Elana
2017-01-01
This study examined predictors of having received HIV and sexually transmitted disease (STD) testing and having been referred by school staff for HIV/STD testing. In 2014, students in seven high schools completed paper-and-pencil questionnaires assessing demographic characteristics, sexual behavior, referrals for HIV/STD testing, and HIV/STD…
Alternative Test Methods for Electronic Parts
NASA Technical Reports Server (NTRS)
Plante, Jeannette
2004-01-01
It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.
Predicting HIV/STD risk level and substance use disorders among incarcerated adolescents.
Rowe, Cynthia L; Wang, Wei; Greenbaum, Paul; Liddle, Howard A
2008-12-01
Incarcerated adolescents are among the most vulnerable groups for STD infection, and substance abuse is prevalent in over half of this population. Substance abuse and HIV/STD-associated risk behaviors are closely linked among juvenile justice-involved youth, but it is unclear whether common antecedents explain these different problems. The current study examined predictors of HIV/STD risk level and substance use disorders, and investigated whether family variables added unique predictive variance for these problems among incarcerated youth. The sample included 154 substance-involved youth ages 13 to 17 recruited in detention facilities in Miami and Tampa, FL and was primarily male (82%) and African-American (58%). Using a comprehensive assessment strategy with data obtained from youth report, parent report, and laboratory confirmed STD testing, the results show that delinquency is a consistent predictor of both HIV/STD risk level and substance use disorders, and also that substance use directly predicts HIV/STD risk level among incarcerated adolescents. Consistent with previous research, family conflict is an important predictor of substance use disorders even after controlling for other factors. The results suggest the need for integrated family-based interventions addressing delinquency, substance abuse, and HIV/STD-associated risk factors with juvenile justice-involved adolescents.
Ma, Qiaoqin; Pan, Xiaohong; Cai, Gaofeng; Yan, Jiezhe; Xu, Yun; Ono-Kihara, Masako; Kihara, Masahiro
2013-01-01
This study is to determine the prevalence of unintended pregnancy and its risk factors among the female attendees of sexually transmitted disease (STD) clinics in Zhejiang Province, China. A self-administered questionnaire survey of a cross-sectional design was administered to attendees at four STD clinics in 2007. Of the 313 female STD clinic attendees, 42.5% reported that they had at least one unintended pregnancy; the induced abortion rate was 39.0%. Over their lifetime, 12.1% responded “use condoms always/often” and 5.4% “always/often used oral contraceptives.” The risk factors for the unintended pregnancy identified by the multivariate analysis were as follows: being married, experience of nonconsensual sex, and a history of STD, having two and over two sexual partners. Unintended pregnancies and induced abortion by female STD clinic attendees have reached an alarming prevalence. Doctors at STD clinics should attach importance not only to the STD problem of the female attendees, but also to the unintended pregnancy and the associated factors. Targeted contraceptive counseling and intervention should be promoted at STD clinics as a strategy to improve the efficiency and effectiveness of the reproductive health services in China. PMID:23841063
Johnson, Amy K; Mikati, Tarek; Mehta, Supriya D
2016-11-09
US surveillance of sexually transmitted diseases (STDs) is often delayed and incomplete which creates missed opportunities to identify and respond to trends in disease. Internet search engine data has the potential to be an efficient, economical and representative enhancement to the established surveillance system. Google Trends allows the download of de-identified search engine data, which has been used to demonstrate the positive and statistically significant association between STD-related search terms and STD rates. In this study, search engine user content was identified by surveying specific exposure groups of individuals (STD clinic patients and university students) aged 18-35. Participants were asked to list the terms they use to search for STD-related information. Google Correlate was used to validate search term content. On average STD clinic participant queries were longer compared to student queries. STD clinic participants were more likely to report using search terms that were related to symptomatology such as describing symptoms of STDs, while students were more likely to report searching for general information. These differences in search terms by subpopulation have implications for STD surveillance in populations at most risk for disease acquisition.
Ma, Qiaoqin; Pan, Xiaohong; Cai, Gaofeng; Yan, Jiezhe; Xu, Yun; Ono-Kihara, Masako; Kihara, Masahiro
2013-01-01
This study is to determine the prevalence of unintended pregnancy and its risk factors among the female attendees of sexually transmitted disease (STD) clinics in Zhejiang Province, China. A self-administered questionnaire survey of a cross-sectional design was administered to attendees at four STD clinics in 2007. Of the 313 female STD clinic attendees, 42.5% reported that they had at least one unintended pregnancy; the induced abortion rate was 39.0%. Over their lifetime, 12.1% responded "use condoms always/often" and 5.4% "always/often used oral contraceptives." The risk factors for the unintended pregnancy identified by the multivariate analysis were as follows: being married, experience of nonconsensual sex, and a history of STD, having two and over two sexual partners. Unintended pregnancies and induced abortion by female STD clinic attendees have reached an alarming prevalence. Doctors at STD clinics should attach importance not only to the STD problem of the female attendees, but also to the unintended pregnancy and the associated factors. Targeted contraceptive counseling and intervention should be promoted at STD clinics as a strategy to improve the efficiency and effectiveness of the reproductive health services in China.
Murakami, Y; Hashimoto, S; Taniguchi, K; Nagai, M
1999-12-01
To describe the characteristics of monitoring stations for the infectious disease surveillance system in Japan, we compared the distributions of the number of monitoring stations in terms of population, region, size of medical institution, and medical specialty. The distributions of annual number of reported cases in terms of the type of diseases, the size of medical institution, and medical specialty were also compared. We conducted a nationwide survey of the pediatrics stations (16 diseases), ophthalmology stations (3 diseases) and the stations of sexually transmitted diseases (STD) (5 diseases) in Japan. In the survey, we collected the data of monitoring stations and the annual reported cases of diseases. We also collected the data on the population, served by the health center where the monitoring stations existed, from the census. First, we compared the difference between the present number of monitoring stations and the current standard established by the Ministry of Health and Welfare (MHW). Second, we compared the distribution of all medical institutions in Japan and the monitoring stations in terms of the size of the medical institution. Third, we compared the average number of annual reported cases of diseases in terms of the size of medical institution and the medical specialty. In most health centers, the number of monitoring stations achieved the current standard of MHW, while a few health centers had no monitoring station, although they had a large population. Most prefectures also achieved the current standard of MHW, but some prefectures were well below the standard. Among pediatric stations, the sampling proportion of large hospitals was higher than other categories. Among the ophthalmology stations, the sampling proportion of hospitals was higher than other categories. Among the STD stations, the sampling proportion of clinics of obstetrics and gynecology was lower than other categories. Except for some diseases, it made little difference in the average number of annual reported cases of diseases in terms of the type of medical institution. Among STD, there was a great difference in the average number of annual reported cases of diseases in terms of medical specialty.
Estimating the Size and Cost of the STD Prevention Services Safety Net.
Gift, Thomas L; Haderxhanaj, Laura T; Torrone, Elizabeth A; Behl, Ajay S; Romaguera, Raul A; Leichliter, Jami S
2015-01-01
The Patient Protection and Affordable Care Act is expected to reduce the number of uninsured people in the United States during the next eight years, but more than 10% are expected to remain uninsured. Uninsured people are one of the main populations using publicly funded safety net sexually transmitted disease (STD) prevention services. Estimating the proportion of the uninsured population expected to need STD services could help identify the potential demand for safety net STD services and improve program planning. In 2013, an estimated 8.27 million people met the criteria for being in need of STD services. In 2023, 4.70 million uninsured people are expected to meet the criteria for being in need of STD services. As an example, the cost in 2014 U.S. dollars of providing chlamydia screening to these people was an estimated $271.1 million in 2013 and is estimated to be $153.8 million in 2023. A substantial need will continue to exist for safety net STD prevention services in coming years.
Estimating the Size and Cost of the STD Prevention Services Safety Net
Haderxhanaj, Laura T.; Torrone, Elizabeth A.; Behl, Ajay S.; Romaguera, Raul A.; Leichliter, Jami S.
2015-01-01
The Patient Protection and Affordable Care Act is expected to reduce the number of uninsured people in the United States during the next eight years, but more than 10% are expected to remain uninsured. Uninsured people are one of the main populations using publicly funded safety net sexually transmitted disease (STD) prevention services. Estimating the proportion of the uninsured population expected to need STD services could help identify the potential demand for safety net STD services and improve program planning. In 2013, an estimated 8.27 million people met the criteria for being in need of STD services. In 2023, 4.70 million uninsured people are expected to meet the criteria for being in need of STD services. As an example, the cost in 2014 U.S. dollars of providing chlamydia screening to these people was an estimated $271.1 million in 2013 and is estimated to be $153.8 million in 2023. A substantial need will continue to exist for safety net STD prevention services in coming years. PMID:26556931
Kessler, Thomas; Neumann, Jörg; Mummendey, Amélie; Berthold, Anne; Schubert, Thomas; Waldzus, Sven
2010-09-01
To explain the determinants of negative behavior toward deviants (e.g., punishment), this article examines how people evaluate others on the basis of two types of standards: minimal and maximal. Minimal standards focus on an absolute cutoff point for appropriate behavior; accordingly, the evaluation of others varies dichotomously between acceptable or unacceptable. Maximal standards focus on the degree of deviation from that standard; accordingly, the evaluation of others varies gradually from positive to less positive. This framework leads to the prediction that violation of minimal standards should elicit punishment regardless of the degree of deviation, whereas punishment in response to violations of maximal standards should depend on the degree of deviation. Four studies assessed or manipulated the type of standard and degree of deviation displayed by a target. Results consistently showed the expected interaction between type of standard (minimal and maximal) and degree of deviation on punishment behavior.
Next generation space interconnect research and development in space communications
NASA Astrophysics Data System (ADS)
Collier, Charles Patrick
2017-11-01
Interconnect or "bus" is one of the critical technologies in design of spacecraft avionics systems that dictates its architecture and complexity. MIL-STD-1553B has long been used as the avionics backbone technology. As avionics systems become more and more capable and complex, however, limitations of MIL-STD-1553B such as insufficient 1 Mbps bandwidth and separability have forced current avionics architects and designers to use combination of different interconnect technologies in order to meet various requirements: CompactPCI is used for backplane interconnect; LVDS or RS422 is used for low and high-speed direct point-to-point interconnect; and some proprietary interconnect standards are designed for custom interfaces. This results in a very complicated system that consumes significant spacecraft mass and power and requires extensive resources in design, integration and testing of spacecraft systems.
2011-05-27
frameworks 4 CMMI-DEV IEEE / ISO / IEC 15288 / 12207 Quality Assurance ©2011 Walz IEEE Life Cycle Processes & Artifacts • Systems Life Cycle Processes...TAG to ISO TC 176 Quality Management • Quality: ASQ, work experience • Software: three books, consulting, work experience • Systems: Telecom & DoD...and IEEE 730 SQA need to align. The P730 IEEE standards working group has expanded the scope of the SQA process standard to align with IS 12207
2015-06-01
events was ad - hoc and problematic due to time constraints and changing requirements. Determining errors in context and heuristics required expertise...area code ) 410-278-4678 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii Contents List of Figures iv 1. Introduction 1...reduction code ...........8 1 1. Introduction Data reduction for analysis of Command, Control, Communications, and Computer (C4) network tests
Mor, Zohar; Shohat, Tamy; Goor, Yael; Dan, Michael
2012-03-01
The increase in human immunodeficiency virus (HIV) among men who have sex with men (MSM) in Israel during the last decade raises concerns regarding other sexuallytransmitted diseases (STD) in MSM, which are yet undetermined. To evaluate the STD burden among MSM and heterosexuals visiting the Tel Aviv walk-in STD clinic. Records of all male patients who attended the clinic once were reviewed to identify demographic characteristics, behavioral attributes, and test results. Between 2002 and 2008, 1064 MSM (22%) and 3755 heterosexuals (78%) visited the clinic once. Positivity rates in MSM for HIV, urethral Neisseria gonorrhoea and infectious syphilis were higher than in heterosexuals (2.5%, 2.5%. 0.7% vs. 0.6%, 1.3%, 0.3%, respectively), while urethral Chlamydia trachomatis was higher in heterosexuals than in MSM (2.7% and 1.4%, respectively). MSM tested in our clinic were younger than heterosexuals (P<0.001), more commonly circumcised (P=0.03) and Israeli-born (P<0.001), used substances during sex (P=0.04), and had prior STD (P<0.001), a greater number of sexual partners (P<0.001), and earlier sexual debut (P=0.02). The final multivariate results for MSM to be diagnosed with HIV/STD were greater number of sexual contacts, previous diagnosis with STD, and infrequent use of condom during anal intercourse. MSM visiting the Levinsky Clinic had higher rates of HIV/STD than heterosexual males, which correlated with their higher-risk behaviors. The unique characteristics of MSM found in our study, such as sex work, substance use, previous diagnosis of STD, multiple partners and inconsistent use of condom during anal sex should be addressed with innovative interventions to prevent STD/HIV in the gay community in Israel.
Leichliter, Jami S; Heyer, Kate; Peterman, Thomas A; Habel, Melissa A; Brookmeyer, Kathryn A; Arnold Pang, Stephanie S; Stenger, Mark R; Weiss, Gretchen; Gift, Thomas L
2017-08-01
We examined the infrastructure for US public sexually transmitted disease (STD) clinical services. In 2013 to 2014, we surveyed 331 of 1225 local health departments (LHDs) who either reported providing STD testing/treatment in the 2010 National Profile of Local Health Departments survey or were the 50 local areas with the highest STD cases or rates. The sample was stratified by jurisdiction population size. We examined the primary referral clinics for STDs, the services offered and the impact of budget cuts (limited to government funding only). Data were analyzed using SAS, and analyses were weighted for nonresponse. Twenty-two percent of LHDs cited a specialty STD clinic as their primary referral for STD services; this increased to 53.5% of LHDs when combination STD-family planning clinics were included. The majority of LHDs (62.8%) referred to clinics providing same-day services. Sexually transmitted disease clinics more frequently offered extragenital testing for chlamydia and/or gonorrhea (74.7%) and gonorrhea culture (68.5%) than other clinics (52.9%, 46.2%, respectively; P < 0.05). The majority of LHDs (61.5%) reported recent budget cuts. Of those with decreased budgets, the most common impacts were fewer clinic hours (42.8%; 95% confidence interval [CI], 24.4-61.2), reduced routine screening (40.2%; 95% CI, 21.7-58.8) and reductions in partner services (42.1%; 95% CI, 23.6-60.7). One quarter of those with reduced STD budgets increased fees or copays for clients. Findings demonstrate gaps and reductions in US public STD services including clinical services that play an important role in reducing disease transmission. Furthermore, STD clinics tended to offer more specialized STD services than other public clinics.
Dynamic Response of Composite Structures Underwater
2013-09-01
then run and the desired data was viewed in CFD-post of the CFX tool. The ANSYS model illustrates the changing concavity of the beam along its...OF ABSTRACT Unclassified 20. LIMITATION OF ABSTRACT UU NSN 7540-01-280-5500 Standard Form 298 (Rev. 2-89) Prescribed by ANSI Std. 239-18...41 Figure 36. ANSYS Beam Displacement
75 FR 29933 - Energy Efficiency and Sustainable Design Standards for New Federal Buildings
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-28
... guidance, discount rates, and energy price projections are determined annually by FEMP and the Energy... Technology Handbook 135: ``Energy Price Indices and Discount Factors for Life-Cycle Cost Analysis.'' FEMP... DEPARTMENT OF ENERGY 10 CFR Parts 433 and 435 [Docket No. EE-RM/STD-02-112] RIN 1904-AC13 Energy...
Installation Boundary Fence Replacement: Upland Areas: Environmental Assessment
2004-05-27
Moody Air Force Base, GA Environmental Assessment Installation Boundary Fence Replacement INSTALLATION BOUNDARY...347 CES/CEV),3485 Georgia Street,Moody AFB, GA ,31699 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Moody Air Force Base, GA Environmental Assessment
40 CFR 89.207 - Credit calculation.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) × (Volume) × (AvgPR) × (UL) × (Adjustment) × (10−6) (ii) For determining credit usage for all engine...) × (Volume) × (AvgPR) × (UL) × (10−6) Where: Std = the applicable Tier 1 NOX nonroad engine emission standard... for end-of-year compliance determination. AvgPR = the average power rating of all of the...
The United States’ Rejection of the International Criminal Court: A Strategic Error
2008-05-09
30 19b. TELEPHONE NUMBER (include area code ) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 USAWC PROGRAM RESEARCH PROJECT THE UNITED...aggression is added to the ICC’s jurisdiction. Aggression as a war crime was charged at Nuremburg , and is a long standing concept in international law
Analysis of Mixing and Dynamics Associated with the Dissolution of Hurricane-Induced Cold Wakes
2016-05-01
Associated with the Dissolution of Hurricane -induced Cold Wakes Sb. GRANT NUMBER N00014-12-I-0188 Sc. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Sd. PROJECT...Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std . Z39.18 Analysis of Mixing and Dynamics Associated with the Dissolution of Hurricane - Induced
7.5K 1bf Thrust Engine Preliminary Design for Orbit Transfer Vehicle. Task D.5
1994-01-01
propellant is burned in the combustion chamber it does not have the losses of open cycles. Its limitations are related to dependence on only one 2 LLC 0 0 0...Unclassified NSN 7540-01-280-5500 Standard Form 296 (Rey. 2-89) Precribed by ANSI Std. Z30-18 298-102
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 1: January
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of January. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Mean density standard deviation (all for 13 levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Willis, Leigh A; Kachur, Rachel; Castellanos, Ted J; Nichols, Kristen; Mendoza, Maria C B; Gaul, Zaneta J; Spikes, Pilgrim; Gamayo, Ashley C; Durham, Marcus D; LaPlace, Lisa; Straw, Julie; Staatz, Colleen; Buge, Hadiza; Hogben, Matthew; Robinson, Susan; Brooks, John; Sutton, Madeline Y
2018-03-01
In the United States, young people (ages 15-24 years) are disproportionately affected by human immunodeficiency virus (HIV) and other sexually transmitted diseases (STDs), due at least in part to inadequate or incorrect HIV/STD-related knowledge, attitudes, beliefs, and behavioral intentions (KABI). Comic book narratives are a proven method of HIV/STD prevention communication to strengthen KABI for HIV/STD prevention. Motion comics, a new type of comic media, are an engaging and low-cost means of narrative storytelling. The objective of this study was to quantitatively evaluate the effectiveness of a pilot six-episode HIV/STD-focused motion comic series to improve HIV/STD-related KABI among young people. We assessed change in HIV/STD knowledge, HIV stigma, condom attitudes, HIV/STD testing attitudes, and behavioral intentions among 138 participants in 15 focus groups immediately before and after viewing the motion comic series. We used paired t-tests and indicators of overall improvement to assess differences between surveys. We found a significant decrease in HIV stigma (p < .001) and increases in both HIV knowledge (p = .002) and behavioral intentions to engage in safe sex (p < .001). In summary, this motion comic intervention improved HIV/STD-related KABI of young adult viewers by reducing HIV stigma and increasing behavioral intentions to engage in safer sex. Our results demonstrate the promise of this novel intervention and support its use to deliver health messages to young people.
Magriples, Urania; Niccolai, Linda M.; Gordon, Derrick M.; Divney, Anna A.; Kershaw, Trace S.
2013-01-01
Few studies have examined whether and how receiving an sexually transmitted disease (STD) diagnosis while in a romantic relationship relates to condom use and psychosocial sexual outcomes. Using dyadic data, we examined associations of a personal or a partner’s STD diagnosis during a relationship with condom use, monogamy intentions, condom intentions and attitudes, and STD susceptibility and communication. Because beliefs about how the STD was acquired may shape associations with behavior and cognitions, gender and suspecting that one’s partner had other sexual partners (i.e., partner concurrency) were examined as moderators. Participants were 592 individuals in 296 couples expecting a baby; 108 individuals had been diagnosed with an STD during the relationship. Personal STD diagnosis was unrelated to outcomes or was associated with increased risk. A partner’s diagnosis related to more positive condom intentions and attitudes. Among men who suspected concurrency, both a personal and a partner’s STD diagnosis were associated with less condom use. Receiving the STD diagnosis during pregnancy was associated with greater susceptibility and marginally greater condom use. Results suggest potential benefits of enhancing communication and encouraging joint risk reduction counseling among couples, engaging men more fully in preventive efforts, and capitalizing on the short window during which risk reduction occurs. PMID:23321987
Senn, Theresa E; Carey, Michael P; Vanable, Peter A
2010-07-01
High rates of psychosocial and health problems have been identified among patients attending sexually transmitted disease (STD) clinics, who are disproportionately urban, have low income, and are racial/ethnic minorities. This study sought to determine whether these problems co-occurred and whether they indicated the presence of a syndemic. Patients (N = 1557, 46% female, 64% African American) attending an urban STD clinic completed a computerized survey assessing childhood sexual abuse (CSA), depressive symptoms, binge drinking, marijuana use, intimate partner violence (IPV), and sexual risk behavior. Medical records were reviewed to determine incident STD diagnosis. The psychosocial and health problems were interrelated. Endorsing more psychosocial problems was associated with a greater likelihood of having multiple sexual partners and STD diagnosis. Interactions between CSA and marijuana use and between CSA and IPV predicted STD diagnosis. Numerous psychosocial and health problems co-occur among urban STD clinic patients. There was some evidence of a syngergistic relationship (i.e., a syndemic) between these conditions, resulting in worsened sexual health outcomes. Health care needs to be multidisciplinary to address the multiple psychosocial and health problems faced by STD clinic patients. Research needs to identify factors that may underlie these comorbid conditions.
Hori, Mika; Kitahashi, Tsukasa; Imai, Toshio; Ishigamori, Rikako; Takasu, Shinji; Mutoh, Michihiro; Sugimura, Takashi; Wakabayashi, Keiji; Takahashi, Mami
2011-11-01
Obesity is associated with increased pancreatic cancer risk, although the mechanisms have yet to be detailed. This study aimed to elucidate promotion of pancreatic cancer by obesity and hyperlipidemia. Six-week-old female Syrian golden hamsters were treated with N-nitrosobis(2-oxopropyl)amine (BOP) and after 1 week were fed a high-fat diet (HFD) or standard diet (STD) for 6 or 17 weeks. Body weight and serum levels of lipids and leptin were significantly higher in the HFD than the STD group at 14 weeks of age. Pancreatic ductal adenocarcinomas developed only in the BOP + HFD group, with an incidence of 67% (P < 0.01) at 14 weeks of age. In addition, the multiplicity was 2-fold greater in the BOP + HFD group than in the BOP + STD group (P < 0.05) at 25 weeks of age. Pancreatic fatty infiltration was increased by BOP treatment and further enhanced by the HFD, correlating with progression of BOP-induced pancreatic ductal adenocarcinoma and up-regulated expression of adipocytokines and cell proliferation-related genes in the pancreas. High-fat diet is shown to increase serum lipid levels and enhance fatty infiltration in the pancreas with abnormal adipocytokine production, which may accelerate and enhance pancreatic cancer.
Effects of exercise and enrichment on behaviour in CD-1 mice.
Aujnarain, Amiirah B; Luo, Owen D; Taylor, Natalie; Lai, Jonathan K Y; Foster, Jane A
2018-04-16
A host of scholarly work has characterized the positive effects of exercise and environmental enrichment on behaviour and cognition in animal studies. The purpose of this study was to investigate the uptake and longitudinal impact of exercise and enrichment on the behavioural phenotype of male and female CD-1 mice. CD-1 mice housed in standard (STD) or exercise and enrichment (EE) conditions post-weaning were tested in the 3-chamber sociability test, open field, and elevated plus maze and exercise activity was monitored throughout the enrichment protocol. Male and female EE mice both showed reduced anxiety and activity in the open field and elevated plus maze relative to sex-matched STD mice. EE altered social behaviours in a sex-specific fashion, with only female EE mice showing increased social preference relative to female STD mice and a preference for social novelty only present in male EE mice. This sexual dimorphism was not observed to be a product of exercise uptake, as CD-1 mice of both sexes demonstrated a consistent trend of wheel rotation frequencies. These findings suggest the importance of considering variables such as sex and strain on experimental design variables in future work on environmental enrichment. Copyright © 2018 Elsevier B.V. All rights reserved.
Zhang, Yifan; Zhang, Shenghui; Marin-Valencia, Isaac; Puchowicz, Michelle A.
2014-01-01
The mechanistic link of ketosis to neuroprotection under certain pathological conditions continues to be explored. We investigated whether chronic ketosis induced by ketogenic diet results in the partitioning of ketone bodies towards oxidative metabolism in brain. We hypothesized that diet-induced ketosis results in increased shunting of ketone bodies towards citric acid cycle (CAC) and amino acids with decreased carbon shunting from glucose. Rats were fed standard (STD) or ketogenic (KG) diets for 3.5 weeks and then infused with [U-13C]glucose or [U-13C]acetoacetate tracers. Concentrations and 13C-labeling pattern of CAC intermediates and amino acids were analyzed from brain homogenates using stable isotopomer mass spectrometry analysis. The contribution of [U-13C]glucose to acetyl-CoA and amino acids decreased by ~30% in the KG group vs STD, whereas [U-13C]acetoacetate contributions were more than 2-fold higher. The concentration of GABA remained constant across all groups; however, the 13C-labeling of GABA was markedly increased in the KG group infused with [U-13C]acetoacetate compared to STD. This study reveals that there is a significant contribution of ketone bodies to oxidative metabolism and GABA in diet-induced ketosis. We propose that this represents a fundamental mechanism of neuroprotection under pathological conditions. PMID:25314677
Comparing Standard Deviation Effects across Contexts
ERIC Educational Resources Information Center
Ost, Ben; Gangopadhyaya, Anuj; Schiman, Jeffrey C.
2017-01-01
Studies using tests scores as the dependent variable often report point estimates in student standard deviation units. We note that a standard deviation is not a standard unit of measurement since the distribution of test scores can vary across contexts. As such, researchers should be cautious when interpreting differences in the numerical size of…
Free-breathing conformal irradiation of pancreatic cancer.
Solla, Ignazio; Zucca, Sergio; Possanzini, Marco; Piras, Sara; Pusceddu, Claudio; Porru, Sergio; Meleddu, Gianfranco; Farace, Paolo
2013-07-08
The purpose of this study was to assess treatment margins in free-breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncertainties were assessed on simulation four-dimensional computed tomography (4D CT) by calculating maximal intrafraction fiducial excursion (MIFE). In the first ten patients, after bony alignment, the position of the fiducial was identified on weekly acquired megavolt cone-beam CT (MV-CBCT). The interfraction residual uncertainties were estimated by measuring the fiducial displacements with respect to the position in the first session. Patient mean (pM) and patient standard deviation (pSD) of fiducial displacement, mean (μM) and standard deviation (μSD) of pM, and root-mean-square of pSD (σ(res)) were calculated. In the other five patients, MIFE was added to the residual component to obtain personalized margin. In these patients, conformal kidney sparing (CONKISS) irradiation was planned prescribing 54/45 Gy to PTV1/PTV2. The organ-at-risk limits were set according to current NCCN recommendation. No morbidity related to the fiducial marker implantation was recorded. In the first ten patients, along right-left, anterior-posterior, and inferior-superior directions, MIFE was variable (mean ± std = 0.24 ± 0.13 cm, 0.31 ± 0.14 cm, 0.83 ± 0.35 cm, respectively) and was at most 0.51, 0.53, and 1.56 cm, respectively. Along the same directions, μM were 0.09, -0.05, -0.05 cm, μSD were 0.30, 0.17, 0.33 cm, and σ(res) were 0.35, 0.26, and 0.30 cm, respectively. MIFE was not correlated with pM and pSD. In the five additional patients, it was possible to satisfy recommended dose limits, with the exception of slightly higher doses to small bowel. After bony alignment, the margins for target expansion can be obtained by adding personalized MIFE to the residual interfraction term. Using these margins, conformal free-breathing irradiation is a reliable option for the treatment of pancreatic cancer.
Free‐breathing conformal irradiation of pancreatic cancer
Solla, Ignazio; Zucca, Sergio; Possanzini, Marco; Piras, Sara; Pusceddu, Claudio; Porru, Sergio; Meleddu, Gianfranco
2013-01-01
The purpose of this study was to assess treatment margins in free‐breathing irradiation of pancreatic cancer after bone alignment, and evaluate their impact on conformal radiotherapy. Fifteen patients with adenocarcinoma of the head of the pancreas underwent implantation of single fiducial marker. Intrafraction uncertainties were assessed on simulation four‐dimensional computed tomography (4D CT) by calculating maximal intrafraction fiducial excursion (MIFE). In the first ten patients, after bony alignment, the position of the fiducial was identified on weekly acquired megavolt cone‐beam CT (MV‐CBCT). The interfraction residual uncertainties were estimated by measuring the fiducial displacements with respect to the position in the first session. Patient mean (pM) and patient standard deviation (pSD) of fiducial displacement, mean (μM) and standard deviation (μSD) of pM, and root‐mean‐square of pSD (σres) were calculated. In the other five patients, MIFE was added to the residual component to obtain personalized margin. In these patients, conformal kidney sparing (CONKISS) irradiation was planned prescribing 54/45 Gy to PTV1/PTV2. The organ‐at‐risk limits were set according to current NCCN recommendation. No morbidity related to the fiducial marker implantation was recorded. In the first ten patients, along right–left, anterior–posterior, and inferior–superior directions, MIFE was variable (mean±std=0.24±0.13cm,0.31±0.14cm,0.83±0.35cm, respectively) and was at most 0.51, 0.53, and 1.56 cm, respectively. Along the same directions, μM were 0.09,−0.05,−0.05cm,μSD were 0.30, 0.17, 0.33 cm, and σres were 0.35, 0.26, and 0.30 cm, respectively. MIFE was not correlated with pM and pSD. In the five additional patients, it was possible to satisfy recommended dose limits, with the exception of slightly higher doses to small bowel. After bony alignment, the margins for target expansion can be obtained by adding personalized MIFE to the residual interfraction term. Using these margins, conformal free‐breathing irradiation is a reliable option for the treatment of pancreatic cancer. PACS number: 87.55.D‐ PMID:23835380
23 CFR 710.501 - Early acquisition.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., requires the STD to demonstrate that: (1) Prior to acquisition, the STD made the certifications and determinations required by 23 U.S.C. 108(c)(2)(C) and (D); and (2) The STD obtained concurrence from the...
23 CFR 710.501 - Early acquisition.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., requires the STD to demonstrate that: (1) Prior to acquisition, the STD made the certifications and determinations required by 23 U.S.C. 108(c)(2)(C) and (D); and (2) The STD obtained concurrence from the...
Sexual Risk Behavior: HIV, STD, & Teen Pregnancy Prevention
... Connect Sexual Health STD Teen Pregnancy Sexual Risk Behaviors: HIV, STD, & Teen Pregnancy Prevention Recommend on Facebook ... No Fear Act OIG 1600 Clifton Road Atlanta , GA 30329-4027 USA 800-CDC-INFO (800-232- ...
Monaco, Serena; Tailford, Louise E; Juge, Nathalie; Angulo, Jesus
2017-11-27
Saturation transfer difference (STD) NMR spectroscopy is extensively used to obtain epitope maps of ligands binding to protein receptors, thereby revealing structural details of the interaction, which is key to direct lead optimization efforts in drug discovery. However, it does not give information about the nature of the amino acids surrounding the ligand in the binding pocket. Herein, we report the development of the novel method differential epitope mapping by STD NMR (DEEP-STD NMR) for identifying the type of protein residues contacting the ligand. The method produces differential epitope maps through 1) differential frequency STD NMR and/or 2) differential solvent (D 2 O/H 2 O) STD NMR experiments. The two approaches provide different complementary information on the binding pocket. We demonstrate that DEEP-STD NMR can be used to readily obtain pharmacophore information on the protein. Furthermore, if the 3D structure of the protein is known, this information also helps in orienting the ligand in the binding pocket. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.
de Codes, José Santiago; Cohen, Deborah Ann; de Melo, Neli Almeida; Teixeira, Guilherme Gonzaga; Leal, Alexandre dos Santos; Silva, Tiago de Jesus; de Oliveira, Miucha Pereira Rios
2006-02-01
The objectives were to study: (1) acceptance of STD screening in non-clinical settings for asymptomatic individuals; (2) risk factors and STD prevalence among individuals in non-clinical and clinical settings; and (3) non-clinical screening of asymptomatic populations as a feasible method for STD control. We recruited 139 males and 486 females between 18 and 30 years of age from a family planning clinic, schools, and community centers in low-income neighborhoods. We asked about STD symptoms and STD/HIV risk behaviors and tested the individuals for gonorrhea, Chlamydia, syphilis, and HIV. Except for HIV, women recruited directly from the community had higher STD rates than those who came in for care at the clinic. Screening in non-clinical settings in Brazil is feasible and has a high yield among young adults in low-income communities. Infected participants would likely never have otherwise sought care or been tested or treated. STD control efforts could be implemented in any site that can reach populations at risk and become a routine procedure in health care settings where people report for problems unrelated to STDs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McClain, B; Olsen, J; Green, O
2015-06-15
Purpose: Online adaptive therapy (ART) relies on auto-contouring using deformable image registration (DIR). DIR’s inherent uncertainties require user intervention and manual edits while the patient is on the table. We investigated the dosimetric impact of DIR errors on the quality of re-optimized plans, and used the findings to establish regions for focusing manual edits to where DIR errors can Result in clinically relevant dose differences. Methods: Our clinical implementation of online adaptive MR-IGRT involves using DIR to transfer contours from CT to daily MR, followed by a physicians’ edits. The plan is then re-optimized to meet the organs at riskmore » (OARs) constraints. Re-optimized abdomen and pelvis plans generated based on physician edited OARs were selected as the baseline for evaluation. Plans were then re-optimized on auto-deformed contours with manual edits limited to pre-defined uniform rings (0 to 5cm) around the PTV. A 0cm ring indicates that the auto-deformed OARs were used without editing. The magnitude of the variations caused by the non-deterministic optimizer was quantified by repeat re-optimizations on the same geometry to determine the mean and standard deviation (STD). For each re-optimized plan, various volumetric parameters for the PTV, the OARs were extracted along with DVH and isodose evaluation. A plan was deemed acceptable if the variation from the baseline plan was within one STD. Results: Initial results show that for abdomen and pancreas cases, a minimum of 5cm margin around the PTV is required for contour corrections, while for pelvic and liver cases a 2–3 cm margin is sufficient. Conclusion: Focusing manual contour edits to regions of dosimetric relevance can reduce contouring time in the online ART process while maintaining a clinically comparable plan. Future work will further refine the contouring region by evaluating the path along the beams, dose gradients near the target and OAR dose metrics.« less
Real-time estimation of BDS/GPS high-rate satellite clock offsets using sequential least squares
NASA Astrophysics Data System (ADS)
Fu, Wenju; Yang, Yuanxi; Zhang, Qin; Huang, Guanwen
2018-07-01
The real-time precise satellite clock product is one of key prerequisites for real-time Precise Point Positioning (PPP). The accuracy of the 24-hour predicted satellite clock product with 15 min sampling interval and an update of 6 h provided by the International GNSS Service (IGS) is only 3 ns, which could not meet the needs of all real-time PPP applications. The real-time estimation of high-rate satellite clock offsets is an efficient method for improving the accuracy. In this paper, the sequential least squares method to estimate real-time satellite clock offsets with high sample rate is proposed to improve the computational speed by applying an optimized sparse matrix operation to compute the normal equation and using special measures to take full advantage of modern computer power. The method is first applied to BeiDou Navigation Satellite System (BDS) and provides real-time estimation with a 1 s sample rate. The results show that the amount of time taken to process a single epoch is about 0.12 s using 28 stations. The Standard Deviation (STD) and Root Mean Square (RMS) of the real-time estimated BDS satellite clock offsets are 0.17 ns and 0.44 ns respectively when compared to German Research Center for Geosciences (GFZ) final clock products. The positioning performance of the real-time estimated satellite clock offsets is evaluated. The RMSs of the real-time BDS kinematic PPP in east, north, and vertical components are 7.6 cm, 6.4 cm and 19.6 cm respectively. The method is also applied to Global Positioning System (GPS) with a 10 s sample rate and the computational time of most epochs is less than 1.5 s with 75 stations. The STD and RMS of the real-time estimated GPS satellite clocks are 0.11 ns and 0.27 ns, respectively. The accuracies of 5.6 cm, 2.6 cm and 7.9 cm in east, north, and vertical components are achieved for the real-time GPS kinematic PPP.
Masturbation and its relationship to sexual activities of young males in Korean military service.
Choi, Y J; Lee, W H; Rha, K H; Xin, Z C; Choi, Y D; Choi, H K
2000-04-01
This study examined the masturbatory experiences and other sexual activities of young Korean males in military service. The actual status of masturbation and its relationship to sexual activity questionnaire. A total of 1,212 young males among military personnel in Korea were interviewed with sexuality questionnaires on masturbation, sexual intercourse and personal characteristics. We divided these subjects into four groups according to the age of initiation of masturbation and analyzed the relationship between masturbation and other sexual activities. The mean age of subjects was 22.03 +/- 1.22 (19-27) years. The percentage of men who reported ever having masturbated was 98.1% (1189/1212) and the average age of initiation of masturbation was 14.26 +/- 1.66 years. So we divided 1,212 males into four groups on the basis of the average age below and above one standard deviation. Overall, 67.7% (821/1212) had experienced sexual intercourse, and significantly, the earlier the initiation age of masturbation, the higher the coitus rate in each group (p < 0.05). About 21.5% of the men who were not virgins had experienced their first sexual intercourse with prostitutes. The mean age of first coitus, the incidence of sexually transmitted disease (STD) and the frequency of masturbation were closely linked to the initiation age of masturbation, respectively (p < 0.05). A masturbatory guilt feeling was seen in about 10.9% (132/1212) and there was no significant difference according to the types of religious worship (p = 0.227). On the basis of this study, sexual activities generally increased accordingly as the beginning of masturbation was earlier. Coital incidence in this study was 67.7% for young males in Korean military service, and 21.5% of them had their first sexual intercourse with prostitutes. Prostitution still plays an important role in the sexual lives of males in Korea. The incidence of STD was over 10% and homosexual manifestation was seen in 1.07% of subjects. Thus a proper and sound sex education at school during childhood is needed in Korea. A large scale survey of sexual behavior in various populations is essential for the improvement of correct sexual concepts.
Amirkhanian, Yuri A; Kelly, Jeffrey A; Takacs, Judit; McAuliffe, Timothy L; Kuznetsova, Anna V; Toth, Tamas P; Mocsonaki, Laszlo; DiFranceisco, Wayne J; Meylakhs, Anastasia
2015-03-13
To test a novel social network HIV risk-reduction intervention for MSM in Russia and Hungary, where same-sex behavior is stigmatized and men may best be reached through their social network connections. A two-arm trial with 18 sociocentric networks of MSM randomized to the social network intervention or standard HIV/STD testing/counseling. St. Petersburg, Russia and Budapest, Hungary. Eighteen 'seeds' from community venues invited the participation of their MSM friends who, in turn, invited their own MSM friends into the study, a process that continued outward until eighteen three-ring sociocentric networks (mean size = 35 members, n = 626) were recruited. Empirically identified network leaders were trained and guided to convey HIV prevention advice to other network members. Changes in sexual behavior from baseline to 3-month and 12-month follow-up, with composite HIV/STD incidence, measured at 12 months to corroborate behavior changes. There were significant reductions between baseline, first follow-up, and second follow-up in the intervention versus comparison arm for proportion of men engaging in any unprotected anal intercourse (UAI) (P = 0.04); UAI with a nonmain partner (P = 0.04); and UAI with multiple partners (P = 0.002). The mean percentage of unprotected anal intercourse acts significantly declined (P = 0.001), as well as the mean number of UAI acts among men who initially had multiple partners (P = 0.05). Biological HIV/STD incidence was 15% in comparison condition networks and 9% in intervention condition networks. Even where same-sex behavior is stigmatized, it is possible to reach MSM and deliver HIV prevention through their social networks.
Sánchez-Blanco, Clara; Amusquivar, Encarnación; Bispo, Kenia; Herrera, Emilio
2016-06-01
The aim was to determine the effects of cafeteria diet (CD) and fish oil supplements given to pregnant and lactating rats on the birth weight and fatty acid profiles of their offspring. Female rats were given standard diet (STD) or CD for 22 days before pregnancy. After mating, some animals remained on STD or CD; for some CD rats, the diet was supplemented with 8.78 % fish oil (CD-FO). After 12 days, half the CD-FO group returned to CD (CD-FO12) and the others remained on CD-FO. At birth, body weights of pups of the three CD groups were lower than STD, maintained until 21 days in the CD-FO group only. At the end of lactation, dams of the CD groups had increased plasma triacylglycerols (TAG), non-esterified fatty acids, and glycerol concentrations, whereas most n-6 long-chain polyunsaturated fatty acids (LCPUFA) were decreased, the effect being greatest in the CD-FO group, where most n-3 LCPUFA were increased and indices of Δ(5) and Δ(6) desaturase activities decreased. The 21-day-old pups of the CD group had increased plasma TAG, not present in the CD-FO group, which had increased 3-hydroxybutyrate concentrations. In both 2- and 21-day-old CD pups, plasma concentrations of ARA were lower than STD, and even lower in the two CD-FO groups. The effect of CD and CD-FO decreasing pups body weight could be related to decreased concentrations of ARA, caused by the inhibition of the Δ(5) and Δ(6) desaturases in the pathway of n-6 LCPUFA biosynthesis.
Saïd, Lamia; Delalande, Christelle; Britton-Davidian, Janice; Saïd, Khaled; Saad, Ali; Carreau, Serge
2007-07-01
House mice (Mus musculus domesticus) in Tunisia consists of two races, one carries the 40-acrocentric standard karyotypes and the other one is a robertsonian race (2n=22) homozygous for nine centric fusions (Rb). The F1 hybrids between the two chromosomal races showed a significant decrease in reproductive success and litter size. Such results can be related to the formation of meiotic trivalent in the hybrids leading to the production of viable aneuploid gametes and post-zygotic elimination of embryos due to chromosomal non disjunction events at meiosis. Moreover, testicular histology of F1 and backcross males showed in some cases a breakdown in spermatogenesis. In both females and males, androgens but also estrogens play an important role in gametogenesis. In this study, we have studied aromatase and estrogen receptor alpha (ERalpha) gene expression in the gonads of the two parental races and their chromosomal hybrids. The results showed that aromatase and ERalpha mRNAs are expressed in hybrid males of inter-racial crosses (female22Rb x male40Std and female40Std x male22Rb) and in hybrid females of inter-racial crosses (female22Rb x male40Std) as in the two parental races. However, in hybrid females of inter-racial crosses (female40Std x male22Rb) the amount of aromatase transcripts decreased sharply suggesting that this gene is involved in the breakdown of hybrid fertility in females, but not in males. However, in hybrid males, a putative post-translational modification of this enzyme, in terms of activity, should be verified.
Amirkhanian, Yuri A.; Kelly, Jeffrey A.; Takacs, Judit; McAuliffe, Timothy L.; Kuznetsova, Anna V.; Toth, Tamas P.; Mocsonaki, Laszlo; DiFranceisco, Wayne J.; Meylakhs, Anastasia
2015-01-01
Objective To test a novel social network HIV risk reduction intervention for MSM in Russia and Hungary, where same-sex behavior is stigmatized and men may best be reached through their social network connections. Design A 2-arm trial with 18 sociocentric networks of MSM randomized to the social network intervention or standard HIV/STD testing/counseling. Setting St. Petersburg, Russia and Budapest, Hungary. Participants 18 “seeds” from community venues invited the participation of their MSM friends who, in turn, invited their own MSM friends into the study, a process that continued outward until eighteen 3-ring sociocentric networks (mean size=35 members, n=626) were recruited. Intervention Empirically-identified network leaders were trained and guided to convey HIV prevention advice to other network members. Main Outcome and Measures Changes in sexual behavior from baseline to 3- and 12-month followup, with composite HIV/STD incidence measured at 12-months to corroborate behavior changes. Results There were significant reductions between baseline, first followup, and second followup in the intervention versus comparison arm for proportion of men engaging in any unprotected anal intercourse (P=.04); UAI with a nonmain partner (P=.04); and UAI with multiple partners (P=.002). The mean percentage of unprotected AI acts significantly declined (P=.001), as well as the mean number of UAI acts among men who initially had multiple partners (P=.05). Biological HIV/STD incidence was 15% in comparison condition networks and 9% in intervention condition networks. Conclusions Even where same-sex behavior is stigmatized, it is possible to reach MSM and deliver HIV prevention through their social networks. PMID:25565495
Optical measurement of isolated canine lung filtration coefficients after alloxan infusion.
Klaesner, J W; Pou, N A; Parker, R E; Finney, C; Roselli, R J
1998-04-01
In this study, lung filtration coefficient (Kfc) was measured in eight isolated canine lung preparations by using three methods: standard gravimetric (Std), blood-corrected gravimetric (BC), and optical. The lungs were held in zone III conditions and were subjected to an average venous pressure increase of 8.79 +/- 0.93 (mean +/- SD) cmH2O. The permeability of the lungs was increased with an infusion of alloxan (75 mg/kg). The resulting Kfc values (in milliliters . min-1 . cmH2O-1 . 100 g dry lung weight-1) measured by using Std and BC gravimetric techniques before vs. after alloxan infusion were statistically different: Std, 0.527 +/- 0.290 vs. 1. 966 +/- 0.283; BC, 0.313 +/- 0.290 vs. 1.384 +/- 0.290. However, the optical technique did not show any statistical difference between pre- and postinjury with alloxan, 0.280 +/- 0.305 vs. 0.483 +/- 0. 297, respectively. The alloxan injury, quantified by using multiple-indicator techniques, showed an increase in permeability and a corresponding decrease in reflection coefficient for albumin (sigmaf). Because the optical method measures the product of Kfc and sigmaf, this study shows that albumin should not be used as an intravascular optical filtration marker when permeability is elevated. However, the optical technique, along with another means of measuring Kfc (such as BC), can be used to calculate the sigmaf of a tracer (in this study, sigmaf of 0.894 at baseline and 0.348 after injury). Another important finding of this study was that the ratio of baseline-to-injury Kfc values was not statistically different for Std and BC techniques, indicating that the percent contribution of slow blood-volume increases does not change because of injury.
Yin, Yue-Ping; Wei, Wan-Hui; Wang, Hong-Chun; Zhu, Bang-Yong; Yu, Yan-Hua; Chen, Xiang-Sheng; Peeling, Rosanna W; Cohen, Myron S
2009-03-01
China is experiencing a growing syphilis epidemic. Individuals are currently screened and cases are confirmed using traditional serological testing methods. A total of 11 558 serum specimens from patients at 14 sexually transmitted diseases (STD) clinics at provincial, prefecture and county levels in Guangxi Autonomous Region were tested at local clinics using the toluidine red unheated serum test (TRUST) and the SD Bioline Syphilis 3.0 Treponema Pallidum (SD-TP) test and then transported to the National STD Reference Laboratory for TRUST and confirmatory Treponema pallidum particle assay (TPPA) testing. In local clinics, 13.2% of specimens were TRUST positive and 12.8% were TRUST and SD-TP positive. At the Reference Laboratory, 15.4% of specimens were TRUST positive and 11.8% were TRUST and TPPA positive. Local clinics showed a significantly higher prevalence of active syphilis compared with results from the Reference Laboratory (12.8 v. 11.8%, chi(2) = 4.59, P = 0.03). The local TRUST tests had consistent results with Reference Laboratory tests qualitatively among 96.2% of the specimens and quantitatively among 95.5% of the specimens. The algorithm of TRUST screening and then SD-TP confirmation among positive TRUST specimens at local STD clinics had 96.6% sensitivity and 99.3% specificity in diagnosing active syphilis compared with the 'gold standard' based on TRUST and TPPA positivity at the Reference Laboratory (positive predictive value 95.1% and negative predictive value 99.5%). The TRUST screening and SD-TP confirmation in combination can be used at local STD clinics for the efficient diagnosis of serologically active syphilis. However, continuing capacity building and quality assurance remain critical in ensuring the quality of syphilis diagnosis at local clinics.
Rusch, Melanie L A; Brouwer, Kimberly C; Lozada, Remedios; Strathdee, Steffanie A; Magis-Rodríguez, Carlos; Patterson, Thomas L
2010-10-01
Sex work is regulated in the Zona Roja (red light district) in Tijuana, Mexico, where HIV and sexually transmitted disease (STD) prevalence is high among female sex workers (FSWs). We examined the spatial distribution of STDs by work venue among FSWs in Tijuana. FSWs aged 18 years and older who reported unprotected sex with ≥ 1 client in the past 2 months underwent testing for HIV, syphilis, gonorrhea, and Chlamydia. HIV/STDs were mapped by venue (i.e., bar, hotel) and Getis-Ord Gi statistics were used to identify geographic hotspots. High-risk venues were then identified using a standardized STD ratio (high risk defined as a ratio ≥ 1.25). Logistic regression was used to assess correlates of working at a high risk venue. Of 474 FSWs, 176 (36.4%) had at least 1 bacterial sexually transmitted infection (STI); 36 (7.6%) were HIV-positive. Within the Zona Roja, 1 venue was identified as a geographic "hotspot," with a higher than expected number of HIV/STD-positive FSW (P < 0.05) as compared to neighboring venues. Using the STD ratio definition, 11 venues were identified as high-risk; FSWs working in these locations had higher education, were more likely to report always using drugs with sex, and having mostly US clients. They were less likely to be registered FSWs or to live at their work venue. A relatively few number of sex work venues accounted for a large proportion of the HIV/STI burden among FSWs in Tijuana. Structural interventions that focus on sex work venues could help increase STI diagnosis, prevention, and treatment among FSWs in Tijuana.
Tsao, Amy C.; Gillilland, Merritt G.; Merchant, Juanita L.
2016-01-01
The impact of omeprazole (OM), a widely used over-the-counter proton pump inhibitor, on weight gain has not been extensively explored. We examined what factors, e.g., diet composition, microbiota, genetic strain, and sex, might affect weight gain in mice fed a high caloric diet while on OM. Inbred C57BL/6J strain, a 50:50 hybrid (B6SJLF1/J) strain, and mice on a highly mixed genetic background were fed four diets: standard chow (STD, 6% fat), STD with 200 ppm OM (STD + O), a high-energy chow (HiE, 11% fat), and HiE chow with OM (HiE + O) for 17 wk. Metabolic analysis, body composition, and fecal microbiota composition were analyzed in C57BL/6J mice. Oral glucose tolerance tests were performed using mice on the mixed background. After 8 wk, female and male C57BL/6J mice on the HiE diets ate less, whereas males on the HiE diets compared with the STD diets gained weight. All diet treatments reduced energy expenditure in females but in males only those on the HiE + O diet. Gut microbiota composition differed in the C57BL/6J females but not the males. Hybrid B6SJLF1/J mice showed similar weight gain on all test diets. In contrast, mixed strain male mice fed a HiE + O diet gained ∼40% more weight than females on the same diet. In addition to increased weight gain, mixed genetic mice on the HiE + O diet cleared glucose normally but secreted more insulin. We concluded that sex and genetic background define weight gain and metabolic responses of mice on high caloric diets and OM. PMID:27810953
Bischel, Alexander; Stratis, Andreas; Kakar, Apoorv; Bosmans, Hilde; Jacobs, Reinhilde; Gassner, Eva-Maria; Puelacher, Wolfgang; Pauwels, Ruben
2016-01-01
Objective: The aim of this study was to evaluate whether application of ultralow dose protocols and iterative reconstruction technology (IRT) influence quantitative Hounsfield units (HUs) and contrast-to-noise ratio (CNR) in dentomaxillofacial CT imaging. Methods: A phantom with inserts of five types of materials was scanned using protocols for (a) a clinical reference for navigated surgery (CT dose index volume 36.58 mGy), (b) low-dose sinus imaging (18.28 mGy) and (c) four ultralow dose imaging (4.14, 2.63, 0.99 and 0.53 mGy). All images were reconstructed using: (i) filtered back projection (FBP); (ii) IRT: adaptive statistical iterative reconstruction-50 (ASIR-50), ASIR-100 and model-based iterative reconstruction (MBIR); and (iii) standard (std) and bone kernel. Mean HU, CNR and average HU error after recalibration were determined. Each combination of protocols was compared using Friedman analysis of variance, followed by Dunn's multiple comparison test. Results: Pearson's sample correlation coefficients were all >0.99. Ultralow dose protocols using FBP showed errors of up to 273 HU. Std kernels had less HU variability than bone kernels. MBIR reduced the error value for the lowest dose protocol to 138 HU and retained the highest relative CNR. ASIR could not demonstrate significant advantages over FBP. Conclusions: Considering a potential dose reduction as low as 1.5% of a std protocol, ultralow dose protocols and IRT should be further tested for clinical dentomaxillofacial CT imaging. Advances in knowledge: HU as a surrogate for bone density may vary significantly in CT ultralow dose imaging. However, use of std kernels and MBIR technology reduce HU error values and may retain the highest CNR. PMID:26859336
Reilley, B; Redd, J T; Giberson, S; Sunde, S; Cullen, T
2011-01-01
We reviewed charts of newly diagnosed STD patients in three health facilities to determine the proportion who received follow-up STD screening. In a 12-month period, the three facilities had 140 STD cases. STD screening was not indicated for 50 (36%) patients. Among the 90 remaining STD patients, 29 (32%) were screened and 61 (68%) not screened. Among non-screened patients, 36% (22/61) were tested, but outside the time parameters allowed by the audit. The remaining 64% (39/61) received no screening at all, and represented clinical missed opportunities; in this group, nearly all (95%) had chlamydia but were not screened for HIV or syphilis. Linking chlamydia patients with a screen for HIV and syphilis using a clinical reminder in the facilities' electronic health record (EHR) or other tool, would eliminate 95% of the missed opportunities in this sample.
Mancia, G; Ferrari, A; Gregorini, L; Parati, G; Pomidossi, G; Bertinieri, G; Grassi, G; Zanchetti, A
1980-12-01
1. Intra-arterial blood pressure and heart rate were recorded for 24 h in ambulant hospitalized patients of variable age who had normal blood pressure or essential hypertension. Mean 24 h values, standard deviations and variation coefficient were obtained as the averages of values separately analysed for 48 consecutive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation aations and variation coefficient were obtained as the averages of values separately analysed for 48 consecurive half-hour periods. 2. In older subjects standard deviation and variation coefficient for mean arterial pressure were greater than in younger subjects with similar pressure values, whereas standard deviation and variation coefficient for heart rate were smaller. 3. In hypertensive subjects standard deviation for mean arterial pressure was greater than in normotensive subjects of similar ages, but this was not the case for variation coefficient, which was slightly smaller in the former than in the latter group. Normotensive and hypertensive subjects showed no difference in standard deviation and variation coefficient for heart rate. 4. In both normotensive and hypertensive subjects standard deviation and even more so variation coefficient were slightly or not related to arterial baroreflex sensitivity as measured by various methods (phenylephrine, neck suction etc.). 5. It is concluded that blood pressure variability increases and heart rate variability decreases with age, but that changes in variability are not so obvious in hypertension. Also, differences in variability among subjects are only marginally explained by differences in baroreflex function.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 7: July
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of July. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 10: October
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of October. Included are global analyses of: (1) Mean temperature/standard deviation; (2) Mean geopotential height/standard deviation; (3) Mean density/standard deviation; (4) Height and vector standard deviation (all at 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point/standard deviation at levels 1000 through 30 mb; and (6) Jet stream at levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 3: March
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-11-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analysis produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of March. Included are global analyses of: (1) Mean Temperature Standard Deviation; (2) Mean Geopotential Height Standard Deviation; (3) Mean Density Standard Deviation; (4) Height and Vector Standard Deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean Dew Point Standard Deviation for levels 1000 through 30 mb; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 2: February
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-09-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of February. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
Joint US Navy/US Air Force climatic study of the upper atmosphere. Volume 4: April
NASA Astrophysics Data System (ADS)
Changery, Michael J.; Williams, Claude N.; Dickenson, Michael L.; Wallace, Brian L.
1989-07-01
The upper atmosphere was studied based on 1980 to 1985 twice daily gridded analyses produced by the European Centre for Medium Range Weather Forecasts. This volume is for the month of April. Included are global analyses of: (1) Mean temperature standard deviation; (2) Mean geopotential height standard deviation; (3) Mean density standard deviation; (4) Height and vector standard deviation (all for 13 pressure levels - 1000, 850, 700, 500, 400, 300, 250, 200, 150, 100, 70, 50, 30 mb); (5) Mean dew point standard deviation for the 13 levels; and (6) Jet stream for levels 500 through 30 mb. Also included are global 5 degree grid point wind roses for the 13 pressure levels.
DeSantis, Michael C; DeCenzo, Shawn H; Li, Je-Luen; Wang, Y M
2010-03-29
Standard deviation measurements of intensity profiles of stationary single fluorescent molecules are useful for studying axial localization, molecular orientation, and a fluorescence imaging system's spatial resolution. Here we report on the analysis of the precision of standard deviation measurements of intensity profiles of single fluorescent molecules imaged using an EMCCD camera.We have developed an analytical expression for the standard deviation measurement error of a single image which is a function of the total number of detected photons, the background photon noise, and the camera pixel size. The theoretical results agree well with the experimental, simulation, and numerical integration results. Using this expression, we show that single-molecule standard deviation measurements offer nanometer precision for a large range of experimental parameters.
Datta, S Deblina; Saraiya, Mona
2011-12-01
In April 2008, experts reviewed updates on sexually transmitted disease (STD) prevention and treatment in preparation for the revision of the Centers for Disease Control and Prevention (CDC) STD Treatment Guidelines. This included a review of cervical cancer screening in the STD clinical setting. Key questions were identified with assistance from an expert panel. Reviews of the literature were conducted using the PubMed computerized database and shared with the panel. Updated information was incorporated in the 2010 CDC STD Treatment Guidelines. We recommend that STD clinics offering cervical screening services screen and treat women according to guidelines by the American College of Obstetrics and Gynecology, the American Cancer Society, the US Preventive Services Task Force, and the American Society for Colposcopists and Cervical Pathologists. New to the 2010 guidelines are higher age for initiating cervical screening (age ≥ 21 years) and less frequent intervals of screening (at least every 3 years). New recommendations include new technologies, such as liquid-based cytology and high-risk human papillomavirus (HPV) DNA tests. Liquid-based technologies are not recommended over conventional testing. HPV DNA tests are recommended as adjunct tests and with new indications for use in cervical screening and management. Stronger recommendations were issued for STD clinics offering cervical screening services to have protocols in place for follow-up of test results and referral (eg, colposcopy). Important additions to the 2010 STD Treatment Guidelines include information on updated algorithms for screening and management of women and recommendations for use of liquid-based cytology and high-risk HPV testing.
Chan, Philip A; Crowley, Christina; Rose, Jennifer S; Kershaw, Trace; Tributino, Alec; Montgomery, Madeline C; Almonte, Alexi; Raifman, Julia; Patel, Rupa; Nunn, Amy
2018-07-01
Sexually transmitted diseases (STDs) are increasing among gay, bisexual, and other men who have sex with men (MSM). Little is known about the use of websites and mobile phone applications to meet sexual partners ("hookup sites") and association with STD diagnoses. We performed a demographic and behavioral assessment of 415 MSM presenting to the Rhode Island STD clinic. Bivariate and multivariable analyses assessed associations between using hookup sites and testing positive for syphilis, gonorrhea, or chlamydia. Venue-based affiliation networks were created to evaluate hookup sites and their association with STD diagnoses. Among 415 MSM, 78% reported meeting a partner online in the last 12 months, and 25% tested positive for at least one STD. Men who met partners online were more likely to be white (67% vs. 54%, P = 0.03) and have more than 10 lifetime partners (87% vs. 58%, P < 0.05). The most commonly used hookup sites included Grindr (78%), Scruff (35%), and Tinder (22%). In the multivariable analysis, only Scruff use was associated with testing positive for an STD (odds ratio, 2.28; 95% confidence interval, 1.09-4.94). However, among men who met partners online, 75% of men diagnosed as having an STD had met a sexual partner on Grindr, including 100% of those who were diagnosed as having gonorrhea. Use of hookup sites was nearly ubiquitous among MSM undergoing STD screening. Specific hookup sites were significantly associated with STD diagnoses among MSM. Greater efforts are needed to promote STD screening and prevention among MSM who meet partners online.
Code of Federal Regulations, 2013 CFR
2013-04-01
... acquired property along the Interstate, the STD shall secure an approval from the FHWA for such change or use. The STD shall specify in the State's ROW operations manual, procedures for the rental, leasing... procedures if approved for use by the STD. ...
Code of Federal Regulations, 2014 CFR
2014-04-01
... acquired property along the Interstate, the STD shall secure an approval from the FHWA for such change or use. The STD shall specify in the State's ROW operations manual, procedures for the rental, leasing... procedures if approved for use by the STD. ...
Zieminski, Stephen; Khandekar, Melin; Wang, Yi
2018-03-01
This study compared the dosimetric performance of (a) volumetric modulated arc therapy (VMAT) with standard optimization (STD) and (b) multi-criteria optimization (MCO) to (c) intensity modulated radiation therapy (IMRT) with MCO for hippocampal avoidance whole brain radiation therapy (HA-WBRT) in RayStation treatment planning system (TPS). Ten HA-WBRT patients previously treated with MCO-IMRT or MCO-VMAT on an Elekta Infinity accelerator with Agility multileaf collimators (5-mm leaves) were re-planned for the other two modalities. All patients received 30 Gy in 15 fractions to the planning target volume (PTV), namely, PTV30 expanded with a 2-mm margin from the whole brain excluding hippocampus with margin. The patients all had metastatic lesions (up to 12) of variable sizes and proximity to the hippocampus, treated with an additional 7.5 Gy from a simultaneous integrated boost (SIB) to PTV37.5. The IMRT plans used eight to eleven non-coplanar fields, whereas the VMAT plans used two coplanar full arcs and a vertex half arc. The averaged target coverage, dose to organs-at-risk (OARs) and monitor unit provided by the three modalities were compared, and a Wilcoxon signed-rank test was performed. MCO-VMAT provided statistically significant reduction of D100 of hippocampus compared to STD-VMAT, and Dmax of cochleas compared to MCO-IMRT. With statistical significance, MCO-VMAT improved V30 of PTV30 by 14.2% and 4.8%, respectively, compared to MCO-IMRT and STD-VMAT. It also raised D95 of PTV37.5 by 0.4 Gy compared to both MCO-IMRT and STD-VMAT. Improved plan quality parameters such as a decrease in overall plan Dmax and total monitor units (MU) were also observed for MCO-VMAT. MCO-VMAT is found to be the optimal modality for HA-WBRT in terms of PTV coverage, OAR sparing and delivery efficiency, compared to MCO-IMRT or STD-VMAT. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
Assessment of Geographic Information Systems and Data Confidentiality Guidelines in STD Programs.
Bissette, Jennifer M; Stover, Jeffrey A; Newman, Lori M; Delcher, Philip Christopher; Bernstein, Kyle T; Matthews, Lindsey
2009-01-01
Advancements in technology, such as geographic information systems (GIS), expand sexually transmitted disease (STD) program capacity for data analysis and visualization, and introduce additional confidentiality considerations. We developed a survey to examine GIS use among STD programs and to better understand existing data confidentiality practices. A Web-based survey of eight to 22 questions, depending on program-specific GIS capacity, was e-mailed to all STD program directors through the National Coalition of STD Directors in November 2004. Survey responses were accepted until April 15, 2005. Eighty-five percent of the 65 currently funded STD programs responded to the survey. Of those, 58% used GIS and 54% used geocoding. STD programs that did not use GIS (42%) identified lack of training and insufficient staff as primary barriers. Mapping, spatial analyses, and targeting program interventions were the main reasons for geocoding data. Nineteen of the 25 programs that responded to questions related to statistical disclosure rules employed a numerator rule, and 56% of those used a variation of the "Rule of 5." Of the 28 programs that responded to questions pertaining to confidentiality guidelines, 82% addressed confidentiality of GIS data informally. Survey findings showed the increasing use of GIS and highlighted the struggles STD programs face in employing GIS and protecting confidentiality. Guidance related to data confidentiality and additional access to GIS software and training could assist programs in optimizing use of spatial data.
Chessa, Daniela; Winter, Maria G; Jakomin, Marcello; Bäumler, Andreas J
2009-02-01
The std operon encodes a fimbrial adhesin of Salmonella enterica serotype Typhimurium that is required for attachment to intestinal epithelial cells and for cecal colonization in the mouse. To study the mechanism by which this virulence factor contributes to colonization we characterized its binding specificity. Std-mediated binding to human colonic epithelial (Caco-2) cells could be abrogated by removing N-linked glycans. Adherence of Std fimbriated S. Typhimurium to Caco-2 cells could be blocked by co-incubation with H type 2 oligosaccharide (Fucalpha1-2Galbeta1-4GlcNAc) or by pretreatment of cells with alpha1-2 fucosidase. In contrast, pretreatment of Caco-2 cells with neuraminidase or co-incubation with the type 2 disaccharide precursor (Galbeta1-4GlcNAc) did not reduce adherence of Std fimbriated S. Typhimurium. Binding of purified Std fimbriae to Fucalpha1-2Galbeta1-4GlcNAc in a solid phase binding assay was competitively inhibited by Ulex europaeus agglutinin-I (UEA-I), a lectin specific for Fucalpha1-2 moieties. Purified Std fimbriae and UEA both bound to a receptor localized in the mucus layer of the murine cecum. These data suggest that the std operon encodes an adhesin that binds an alpha1-2 fucosylated receptor(s) present in the cecal mucosa.
Goldsberry, Jennifer; Moore, Leslie; MacMillan, Deborah; Butler, Scott
2016-04-01
College years are a time young adults examine high-risk sexual behaviors, increasing their risk for sexually transmitted diseases (STDs). Fraternity/sorority membership has been identified as one factor contributing to increased risky sexual behavior in college students. This study measured the effectiveness of an educational intervention targeting STD prevention in fraternity and sorority members, and examined relationships between STD knowledge, attitudes, and demographics. A descriptive, correlational design was used. Pre- and posttest data were collected from fraternity and sorority members (N = 132). Instruments measured demographic characteristics, STD knowledge, and attitudes toward safe sex behaviors. There was a significant increase in STD knowledge from baseline (M = 13.03, SD = 6.5) to 1 week (M = 20.27, SD = 4.9) t (131) = -13.53, p = .000. Males were more likely to report attitudes toward risky sexual behavior rs(132) = .323, p = .000, and as knowledge increased, attitudes became more favorable to safe sex behaviors (pre-STD knowledge and preintervention attitudes, r(132) = -.249, p = .004; post-STD knowledge and postintervention attitudes, rs(132) = -.307, p = .000). Results support that brief STD educational interventions can increase STD knowledge. College health centers must aim to provide sexual health education to all students at every visit. ©2016 American Association of Nurse Practitioners.
Chessa, Daniela; Winter, Maria G.; Jakomin, Marcello; Bäumler, Andreas J.
2013-01-01
SUMMARY The std operon encodes a fimbrial adhesin of Salmonella enterica serotype Typhimurium that is required for attachment to intestinal epithelial cells and for cecal colonization in the mouse. To study the mechanism by which this virulence factor contributes to colonization we characterized its binding specificity. Std-mediated binding to human colonic epithelial (Caco-2) cells could be abrogated by removing N-linked glycans. Adherence of Std fimbriated S. Typhimurium to Caco-2 cells could be blocked by co-incubation with H type 2 oligosaccharide (Fucα1-2Galβ1-4GlcNAc) or by pretreatment of cells with α1-2 fucosidase. In contrast, pretreatment of Caco-2 cells with neuraminidase or co-incubation with the type 2 disaccharide precursor (Galβ1-4GlcNAc) did not reduce adherence of Std fimbriated S. Typhimurium. Binding of purified Std fimbriae to Fucα1-2Galβ1-4GlcNAc in a solid phase binding assay was competitively inhibited by Ulex europaeus agglutinin-I (UEA-I), a lectin specific for Fucα1-2 moieties. Purified Std fimbriae and UEA both bound to a receptor localized in the mucus layer of the murine cecum. These data suggest that the std operon encodes an adhesin that binds an α1-2 fucosylated receptor(s) present in the cecal mucosa. PMID:19183274
Spauwen, Laura W L; Hoebe, Christian J P A; Brouwers, Elfi E H G; Dukers-Muijrers, Nicole H T M
2011-09-30
Chlamydia trachomatis infection (CT) is the most prevalent bacterial STD. Sexually active adolescents and young adults are the main risk group for CT. However, STD testing rates in this group are low since exposed individuals may not feel at risk, owing-at least in part-to the infection's largely asymptomatic nature. Designing new testing environments that are more appealing to young people who are most at risk of acquiring chlamydia can be an important strategy to improve overall testing rates. Here we evaluate the effect of a school-based sexual health program conducted among vocational school students, aiming to obtain better access for counseling and enhance students' STD testing behavior. Adolescents (median age 19 years) attending a large vocational school were provided with sexual health education. Students filled in a questionnaire measuring CT risk and were offered STD testing. Using univariate and multivariate analysis, we assessed differences between men and women in STD-related risk behavior, sexual problems, CT testing behavior and determinants of CT testing behavior. Of 345 participants, 70% were female. Of the 287 sexually active students, 75% were at high risk for CT; one third of women reported sexual problems. Of sexually active participants, 61% provided a self-administered specimen for STD testing. Independent determinants for testing included STD related symptoms and no condom use. All CT diagnoses were in the high-CT-risk group. In the high-risk group, STD testing showed an increased uptake, from 27% (previous self-reported test) to 65% (current test). CT prevalence was 5.7%. Vocational school students are a target population for versatile sexual health prevention. When provided with CT testing facilities and education, self selection mechanisms seemed to increase CT testing rate dramatically in this high-CT-risk population expressing sexual problems. Considering the relative ease of testing and treating large numbers of young adults, offering tests at a vocational school is feasible in reaching adolescents for STD screening. Although cost-effectiveness remains an issue counseling is effective in increasing test rates.
Namekawa, Junichi; Takagi, Yoshiichi; Wakabayashi, Kaoru; Nakamura, Yuki; Watanabe, Ayaka; Nagakubo, Dai; Shirai, Mitsuyuki; Asai, Fumitoshi
2017-06-10
Obesity and type 2 diabetes mellitus (T2DM) are occurring at epidemic-like rates, and these epidemics appear to have emerged largely from changes in daily diet. In the present study, we compared effects of high-fat diet (HFD) and fructose-rich diet (FRD) in WBN/Kob-Lepr fa (WBKDF) rats that spontaneously develop obesity, dyslipidemia and T2DM. After a 4-week feeding of each diet, WBKDF-HFD and WBKDF-FRD rats exhibited aggravated obesity and dyslipidemia compared with WBKDF rats fed standard diet (STD). In contrast, hyperglycemia developed in WBKDF-STD rats was significantly inhibited in WBKDF-FRD rats, but not in WBKDF-HFD rats. The present study demonstrated that the 4-week feeding of HFD and FRD caused diet-induced obesity with a distinct phenotype in the glucose metabolism in WBKDF rats.
NAMEKAWA, Junichi; TAKAGI, Yoshiichi; WAKABAYASHI, Kaoru; NAKAMURA, Yuki; WATANABE, Ayaka; NAGAKUBO, Dai; SHIRAI, Mitsuyuki; ASAI, Fumitoshi
2017-01-01
Obesity and type 2 diabetes mellitus (T2DM) are occurring at epidemic-like rates, and these epidemics appear to have emerged largely from changes in daily diet. In the present study, we compared effects of high-fat diet (HFD) and fructose-rich diet (FRD) in WBN/Kob-Leprfa (WBKDF) rats that spontaneously develop obesity, dyslipidemia and T2DM. After a 4-week feeding of each diet, WBKDF-HFD and WBKDF-FRD rats exhibited aggravated obesity and dyslipidemia compared with WBKDF rats fed standard diet (STD). In contrast, hyperglycemia developed in WBKDF-STD rats was significantly inhibited in WBKDF-FRD rats, but not in WBKDF-HFD rats. The present study demonstrated that the 4-week feeding of HFD and FRD caused diet-induced obesity with a distinct phenotype in the glucose metabolism in WBKDF rats. PMID:28442647
Code of Federal Regulations, 2014 CFR
2014-04-01
... program. All factors that comprise the State transportation department's (STD) determination of the... which are performed in the STD's central laboratory would not be covered by an independent assurance... STD. As a minimum, the qualification program shall include provisions for checking test equipment and...
Code of Federal Regulations, 2012 CFR
2012-04-01
... program. All factors that comprise the State transportation department's (STD) determination of the... which are performed in the STD's central laboratory would not be covered by an independent assurance... STD. As a minimum, the qualification program shall include provisions for checking test equipment and...
Code of Federal Regulations, 2013 CFR
2013-04-01
... program. All factors that comprise the State transportation department's (STD) determination of the... which are performed in the STD's central laboratory would not be covered by an independent assurance... STD. As a minimum, the qualification program shall include provisions for checking test equipment and...
Code of Federal Regulations, 2011 CFR
2011-04-01
... program. All factors that comprise the State transportation department's (STD) determination of the... which are performed in the STD's central laboratory would not be covered by an independent assurance... STD. As a minimum, the qualification program shall include provisions for checking test equipment and...
2003-08-18
Language Study 5c. PROGRAM ELEMENT NUMBER 5d. PROJECT NUMBER 5d. TASK NUMBER 6. AUTHOR(S) Professor Mads Dam, Pablo Giambiagi 5e...Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39-18 SPC 01-4025 Mobile Language Study Final...smart card applications. Smart cards can be programmed using general-purpose languages ; but because of their limited resources, smart card programs
Effectiveness of CAI Package on Achievement in Physics of IX Standard Students
ERIC Educational Resources Information Center
Maheswari, I. Uma; Ramakrishnan, N.
2015-01-01
The present study is an experimental one in nature, to find out the effectiveness of CAI package on in Physics of IX std. students. For this purpose a CAI package was developed and validated. The validated CAI package formed an independent variable of this study. The dependent variable is students' achievements in physics content. In order to find…
Peptide Nanotube Reinforced Polymers: A System for Tunable, Composite Materials
2015-11-30
Standard Form 298 (Rev 8/98) Prescribed by ANSI Std. Z39.18 617-432-7730 W911NF-12-1-0229 62177- LS -II.3 Final Report a. REPORT 14. ABSTRACT 16...dangerous!!! (Germ Theory of Disease) Pasteur and Koch, early 19th century 1% 1,2.#Wikimedia#Commons,#3.#Time# Magazine ,#Inc.,#4.#Genentech,#5.#J
Configuration management program plan for Hanford site systems engineering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kellie, C.L.
This plan establishes the integrated management program for the evolving technical baseline developed through the systems engineering process. This configuration management program aligns with the criteria identified in the DOE Standard, DOE-STD-1073-93. Included are specific requirements for control of the systems engineering RDD-100 database, and electronic data incorporated in the database that establishes the Hanford Site Technical Baseline.
In Situ Bioremediation of Perchlorate in Groundwater
2009-07-01
Inc. Jay Diebold Shaw Environmental, Inc. Approved for public release; distribution unlimited. Standard Form 298...Rev. 8/98) REPORT DOCUMENTATION PAGE Prescribed by ANSI Std. Z39.18 Form Approved OMB No. 0704-0188 The public reporting burden for this...Approved for Public Release, Distribution is Unlimited None A field demonstration was conducted to evaluate the in situ treatment of perchlorate using a
Nurses’ Role in the Joint Theater Trauma System
2008-12-01
elevation, etc) and input for ventilator-associated pneumonia and infection control CPGs. In addition, a methicillin - resistant Staphylococcus aureus and...Standard Form 298 (Rev. 8-98) Prescribed by ANSI-Std Z39-18 REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden...MONITORING AGENCY REPORT NUMBER 12. DISTRIBUTION AVAILABILITY STATEMENT Distribution A: Approved for public release; distribution is
Information Assurance: Trends in Vulnerabilities, Threats, and Technologies
2004-01-01
Capacity for Change,” in Transforming Defense, edited by Conrad C . Crane (Carlisle, PA: Strategic Studies Institute, December 2001. 18 John J. White...unclassified c . THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Information Assurance Trends in Vulnerabilities...49 John D. Rosenberger Chapter 4 Dealing with Physical Vulnerabilities . . . . . . . . . . .55 Bruce W. MacDonald vii
Towards Wearable Cognitive Assistance
2013-12-01
ABSTRACT unclassified c. THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Keywords: mobile computing, cloud...It presents a muli-tiered mobile system architecture that offers tight end-to-end latency bounds on compute-intensive cognitive assistance...to an entire neighborhood or an entire city is extremely expensive and time-consuming. Physical infrastructure in public spaces tends to evolve very
Accurate Arabic Script Language/Dialect Classification
2014-01-01
Army Research Laboratory Accurate Arabic Script Language/Dialect Classification by Stephen C. Tratz ARL-TR-6761 January 2014 Approved for public...1197 ARL-TR-6761 January 2014 Accurate Arabic Script Language/Dialect Classification Stephen C. Tratz Computational and Information Sciences...Include area code) Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 January 2014 Final Accurate Arabic Script Language/Dialect Classification
Efficient and Robust Signal Approximations
2009-05-01
otherwise. Remark. Permutation matrices are both orthogonal and doubly- stochastic [62]. We will now show how to further simplify the Robust Coding...reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 Keywords: signal processing, image compression, independent component analysis , sparse
RAF and Sustainment Warfighting Function
2015-02-01
doctrinally require only limited external augmentation to conduct the full range of military operations (ROMO).7 Report Documentation Page Form ...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 72 Regionally Aligned Forces: Concept Viability and Implementation United States Army...services encompass a wide range of human resource management, financial, legal, religious, and military band support.11 Health service support ( HSS
Ocean Variability Effects on Underwater Acoustic Communications
2011-09-01
schemes for accessing wide frequency bands. Compared with OFDM schemes, the multiband MIMO transmission combined with time reversal processing...systems, or multiple- input/multiple-output ( MIMO ) systems, decision feedback equalization and interference cancellation schemes have been integrated...unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 2 MIMO receiver also iterates channel estimation and symbol demodulation with
Air Force Officer Force Development, an Analysis and Future Issues
2004-02-27
Kotter’s Eight Steps John P. Kotter is a Konosuke Matsushita Professor of Leadership at the Harvard Business School, and is an internationally...PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 DISCLAIMER The views expressed in this academic research paper are...Employees for Broad -Based Action ......................................................13 Generating Short-Term Wins
Technical Note: Some Issues Related to the Selection of Polymers for Aerospace Oxygen Systems
NASA Technical Reports Server (NTRS)
Hirsch, David; Beeson, Harold
2004-01-01
Materials intended for use in aerospace oxygen systems are commonly screened for oxygen compatibility following NASA STD 6001. This standard allows qualification of materials based on results provided by only one test method. Potential issues related to this practice are reviewed and recommendations are proposed that would lead to improved aerospace oxygen systems safety.
Spring 2006. Industry Study. Information Technology Industry
2006-01-01
unclassified c . THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 i Information Technology 2006 ABSTRACT...integration of processors, coprocessors, memory, storage, etc. into a user-programmable final product. C . Software (Apple, Oracle): These firms...able to support the U.S. national security interests. C . Manufacturing: The personal computer manufacturing industry has also changed considerably
Assessment of Multiple Launch Rocket System (MLRS) Training Strategy
1992-04-01
Unclassified Unclassified Unlimited NSN 7540-01-280-5500 Standard Form 298 (Rev 2-89) i Precribed by AN % Std Z39-18296-102? ARI Research Report 1614 13...Chiefs reported that they can get to be monotonous for the troops and produce " burn out"(9o 12 14)* 33 Post Number 2 reported success with Best-by
2013-08-23
REPORT Stablization of Nanotwinned Microstructures in Stainless Steels Through Alloying and Microstructural Design 14. ABSTRACT 16. SECURITY...15. SUBJECT TERMS materials design, stainless steels , plastic deformation by twinning, computational materials science, experimental characterization...Standard Form 298 (Rev 8/98) Prescribed by ANSI Std. Z39.18 - 30-Jun-2013 Stablization of Nanotwinned Microstructures in Stainless Steels Through
2014-12-01
Area Code) (937) 528-8142 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18 1 MITCHELL, LOLITA V CIV USAF AFMC AFRL/RYOX To...MITCHELL, LOLITA V CIV USAF AFMC AFRL/RYOX Subject: FW: Final Report Change - Search and Rescue Security Assessment From: J M Schlesselman [mailto:joe
Maruyama, Shuki; Fukushima, Yasuhiro; Miyamae, Yuta; Koizumi, Koji
2018-06-01
This study aimed to investigate the effects of parameter presets of the forward projected model-based iterative reconstruction solution (FIRST) on the accuracy of pulmonary nodule volume measurement. A torso phantom with simulated nodules [diameter: 5, 8, 10, and 12 mm; computed tomography (CT) density: - 630 HU] was scanned with a multi-detector CT at tube currents of 10 mA (ultra-low-dose: UL-dose) and 270 mA (standard-dose: Std-dose). Images were reconstructed with filtered back projection [FBP; standard (Std-FBP), ultra-low-dose (UL-FBP)], FIRST Lung (UL-Lung), and FIRST Body (UL-Body), and analyzed with a semi-automatic software. The error in the volume measurement was determined. The errors with UL-Lung and UL-Body were smaller than that with UL-FBP. The smallest error was 5.8% ± 0.3 for the 12-mm nodule with UL-Body (middle lung). Our results indicated that FIRST Body would be superior to FIRST Lung in terms of accuracy of nodule measurement with UL-dose CT.
Willis, Leigh A; Kachur, Rachel; Castellanos, Ted J; Spikes, Pilgrim; Gaul, Zaneta J; Gamayo, Ashley C; Durham, Marcus; Jones, Sandra; Nichols, Kristen; Han Barthelemy, Solange; LaPlace, Lisa; Staatz, Colleen; Hogben, Matthew; Robinson, Susan; Brooks, John T; Sutton, Madeline Y
2018-02-01
Young people (15-24 years) in the United States are disproportionately affected by infection with human immunodeficiency virus (HIV) and sexually transmitted diseases (STD). Shortfalls in HIV/STD-related knowledge, attitudes, beliefs, and behavioral intentions (KABI) likely contribute to this discrepancy. In this report we describe our experience developing a novel means of health communication combining entertainment-education theory and recent technological advances to create a HIV/STD-focused "motion comic." We also report the audience satisfaction and acceptance of the intervention. We used the Health Belief Model (HBM), entertainment-education (EE) principles, and the Sabido Method (SM) and conducted three rounds of focus groups to develop a 38-minute HIV/STD focused motion comic for young people between the ages 15 and 24 years. Participants indicated that motion comics were an acceptable method of delivering HIV/STD prevention messages. They also expressed satisfaction with motion comics plot, story settings, the tone of humor, and drama. Our results suggest that motion comics are a viable new method of delivering health communication messages about HIV/STD and other public health issues, and warrant further development and broader evaluation.
NASA Astrophysics Data System (ADS)
Yuan, Wu-Jie; Zhou, Jian-Fang; Zhou, Changsong
2016-04-01
Microsaccades are very small eye movements during fixation. Experimentally, they have been found to play an important role in visual information processing. However, neural responses induced by microsaccades are not yet well understood and are rarely studied theoretically. Here we propose a network model with a cascading adaptation including both retinal adaptation and short-term depression (STD) at thalamocortical synapses. In the neural network model, we compare the microsaccade-induced neural responses in the presence of STD and those without STD. It is found that the cascading with STD can give rise to faster and sharper responses to microsaccades. Moreover, STD can enhance response effectiveness and sensitivity to microsaccadic spatiotemporal changes, suggesting improved detection of small eye movements (or moving visual objects). We also explore the mechanism of the response properties in the model. Our studies strongly indicate that STD plays an important role in neural responses to microsaccades. Our model considers simultaneously retinal adaptation and STD at thalamocortical synapses in the study of microsaccade-induced neural activity, and may be useful for further investigation of the functional roles of microsaccades in visual information processing.
Exploring Students' Conceptions of the Standard Deviation
ERIC Educational Resources Information Center
delMas, Robert; Liu, Yan
2005-01-01
This study investigated introductory statistics students' conceptual understanding of the standard deviation. A computer environment was designed to promote students' ability to coordinate characteristics of variation of values about the mean with the size of the standard deviation as a measure of that variation. Twelve students participated in an…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2012 CFR
2012-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2014 CFR
2014-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2011 CFR
2011-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2013 CFR
2013-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
Statistics as Unbiased Estimators: Exploring the Teaching of Standard Deviation
ERIC Educational Resources Information Center
Wasserman, Nicholas H.; Casey, Stephanie; Champion, Joe; Huey, Maryann
2017-01-01
This manuscript presents findings from a study about the knowledge for and planned teaching of standard deviation. We investigate how understanding variance as an unbiased (inferential) estimator--not just a descriptive statistic for the variation (spread) in data--is related to teachers' instruction regarding standard deviation, particularly…
7 CFR 801.4 - Tolerances for dockage testers.
Code of Federal Regulations, 2010 CFR
2010-01-01
....10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Riddle separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Sieve separation ±0.10 percent, mean deviation from standard dockage tester using Hard Red Winter wheat Total...
7 CFR 801.6 - Tolerances for moisture meters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat Mid ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat High ±0.05 percent moisture, mean deviation from National standard moisture meter using Hard Red Winter wheat...
23 CFR 710.201 - State responsibilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... REAL ESTATE Program Administration § 710.201 State responsibilities. (a) Organization. Each STD shall... responsibilities. (b) Program oversight. The STD shall have overall responsibility for the acquisition, management... Federal laws and regulations. (c) Right-of-way (ROW) operations manual. Each STD which receives funding...
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2012 CFR
2012-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2014 CFR
2014-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
23 CFR 637.207 - Quality assurance program.
Code of Federal Regulations, 2013 CFR
2013-04-01
... program. (a) Each STD's quality assurance program shall provide for an acceptance program and an independent assurance (IA) program consisting of the following: (1) Acceptance program. (i) Each STD's... STD shall establish a dispute resolution system. The dispute resolution system shall address the...
23 CFR 710.201 - State responsibilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... REAL ESTATE Program Administration § 710.201 State responsibilities. (a) Organization. Each STD shall... responsibilities. (b) Program oversight. The STD shall have overall responsibility for the acquisition, management... Federal laws and regulations. (c) Right-of-way (ROW) operations manual. Each STD which receives funding...
AIDS phobia: report of 4 cases.
Ross, M W
1988-01-01
Psychological reactions to sexually transmissible disease (STD) infection are common, occurring in up to 85% of some patients with STDs: Hart has suggested that they are among the most common conditions encountered in venereology. Previous psychiatric disturbances in STD patients, however, are relatively uncommon and differ in both etiology and management from such psychological sequelae of STD infection, although both Catalan et al. and Fitzpatrick et al. report that in the United Kingdom, some 40% of STD clinic attenders had General Health Questionnaire scores indicating they were psychiatric cases.
Inventory of File sref.t03z.pgrb197.spread_ds_3hrly.grib2
3 hour fcst U-Component of Wind [m/s] std dev 002 10 m above ground VGRD 3 hour fcst V-Component of Wind [m/s] std dev 003 2 m above ground TMP 3 hour fcst Temperature [K] std dev 004 2 m above ground SPFH 3 hour fcst Specific Humidity [kg/kg] std dev 005 10 m above ground WIND 3 hour fcst Wind Speed [m
Man-systems requirements for the control of teleoperators in space
NASA Technical Reports Server (NTRS)
Shields, Nicholas L., Jr.
1988-01-01
The microgravity of the space environment has profound effects on humans and, consequently, on the design requirements for subsystems and components with which humans interact. There are changes in the anthropometry, vision, the perception of orientation, posture, and the ways in which we exert energy. The design requirements for proper human engineering must reflect each of the changes that results, and this is especially true in the exercise of control over remote and teleoperated systems where the operator is removed from any direct sense of control. The National Aeronautics and Space Administration has recently completed the first NASA-wide human factors standard for microgravity. The Man-Systems Integration Standard, NASA-STD-3000, contains considerable information on the appropriate design criteria for microgravity, and there is information that is useful in the design for teleoperated systems. There is not, however, a dedicated collection of data which pertains directly to the special cases of remote and robotic operations. The design considerations for human-system interaction in the control of remote systems in space are discussed, with brief details on the information to be found in the NASA-STD-3000, and arguments for a dedicated section within the Standard which deals with robotic, teleoperated and remote systems and the design requirements for effective human control of these systems in the space environment, and from the space environment.
Missed opportunities for concurrent HIV-STD testing in an academic emergency department.
Klein, Pamela W; Martin, Ian B K; Quinlivan, Evelyn B; Gay, Cynthia L; Leone, Peter A
2014-01-01
We evaluated emergency department (ED) provider adherence to guidelines for concurrent HIV-sexually transmitted disease (STD) testing within an expanded HIV testing program and assessed demographic and clinical factors associated with concurrent HIV-STD testing. We examined concurrent HIV-STD testing in a suburban academic ED with a targeted, expanded HIV testing program. Patients aged 18-64 years who were tested for syphilis, gonorrhea, or chlamydia in 2009 were evaluated for concurrent HIV testing. We analyzed demographic and clinical factors associated with concurrent HIV-STD testing using multivariate logistic regression with a robust variance estimator or, where applicable, exact logistic regression. Only 28.3% of patients tested for syphilis, 3.8% tested for gonorrhea, and 3.8% tested for chlamydia were concurrently tested for HIV during an ED visit. Concurrent HIV-syphilis testing was more likely among younger patients aged 25-34 years (adjusted odds ratio [AOR] = 0.36, 95% confidence interval [CI] 0.78, 2.10) and patients with STD-related chief complaints at triage (AOR=11.47, 95% CI 5.49, 25.06). Concurrent HIV-gonorrhea/chlamydia testing was more likely among men (gonorrhea: AOR=3.98, 95% CI 2.25, 7.02; chlamydia: AOR=3.25, 95% CI 1.80, 5.86) and less likely among patients with STD-related chief complaints at triage (gonorrhea: AOR=0.31, 95% CI 0.13, 0.82; chlamydia: AOR=0.21, 95% CI 0.09, 0.50). Concurrent HIV-STD testing in an academic ED remains low. Systematic interventions that remove the decision-making burden of ordering an HIV test from providers may increase HIV testing in this high-risk population of suspected STD patients.
Meng, Xiaojun; Zou, Huachun; Jia, Tianjian; Zhu, Chen; Chen, Xin; Zhang, Xuan
2015-12-01
To understand the willingness on acceptance of a short-messageservice (SMS) program provided for HIV/STD testing and the related factors, among male clients at the STD clinics in China. Convenience sampling method was used to select study subjects at a STD clinic in Wuxi, Jiangsu province. A questionnaire survey was conducted among the subjects to collect the information on socio-demographic characteristics and willingness of acceptance to the SMS. A total of 368 SMS subjects were surveyed, in which 75.5% expressed the willingness of acceptance, while 57.2% and 38.1% of them wanted to receive the short message every 3 months or 6 months, respectively. 53.8% of the respondents showed their willingness to share the news with their sexual partners about SMS and 44.8% of them would do the same to their friends. Data from the Multivariate logistic regression analysis showed that those who had received senior high school or above education (aOR=3.632, 95%CI: 1.939-6.715) , having homosexual behavior (aOR = 1.973, 95%CI: 1.234-8.358) or those having received AIDS related intervention service in the past year (aOR=9.416, 95%CI: 4.822-18.309) were more likely to accept the SMS. SMS seemed to be acceptable among the male STD clinic clients in Wuxi, suggesting that it is feasible to conduct the SMS as a strategy to improve the HIV/STDs testing program at the STD clinics in the future. Promotion of SMS should be strengthened and the provision of general AIDS intervention service at the STD clinics should be established in order to make more STD clinic clients understand this SMS.